Sample records for common laboratory test

  1. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  2. Diagnosis of canine hypothyroidism. Perspectives from a testing laboratory.

    PubMed

    Kemppainen, R J; Behrend, E N

    2001-09-01

    The most common sample received by our endocrine testing laboratory is submitted for the diagnosis of hypothyroidism in a dog. The current tests most frequently employed in our laboratory for thyroid evaluation in dogs are total T4, free T4 by dialysis, and canine TSH measurement. Each test has strengths and weaknesses and suffers from the possibility of both false positive and false negative results. This article provides a working description of each test and an approach to interpretation of results. Other tests that are less commonly used are also discussed. Examples of interpretation of test results in individual hypothyroid-suspect dogs are presented for illustration.

  3. Evaluation of Iranian microbiology laboratories for identification of etiologic agents of bacterial meningitidis. Survey results of an external quality assessment scheme (EQAS) programme.

    PubMed

    Marandi, Farinaz Rashed; Rahbar, Mohammad; Sabourian, Roghieh; Saremi, Mahnaz

    2010-01-01

    To determine the ability of Iranian microbiology laboratories for identification and susceptibility testing of Streptococcus pneumoniae and Haemophilus influenzae as causative agents of bacterial meningitides. Two strains of bacteria including Haemophilus influenzae and Streptococcus pneumoniae as a common causative agents of meningitides were chosen and coded as strain number 1 and number 2. The strains were distributed among 679 microbiology laboratories. All laboratories were requested for identification of each unknown microorganism and susceptibility testing of S. pneumoniae against five commonly used antibiotics. Of 679 microbiology laboratories 310 (46%) laboratories participated in the survey and among these, 258 laboratories completely identified S. pneumoniae. About 85% laboratories produced correct susceptibility testing against oxacillin, erythromycin, tetracycline, and vancomycin. Of 310 received responses only 50 laboratories identified H. influenza correctly. The majority of the laboratories did not have the capacity to identification H. influenza. Microbiology laboratories in our country are qualified for identification and susceptibility testing of S. pneumoniae. However, majority of laboratories are not qualified for identification of H. influenzae.

  4. Chronic myelogenous leukemia: laboratory diagnosis and monitoring.

    PubMed

    Wang, Y L; Bagg, A; Pear, W; Nowell, P C; Hess, J L

    2001-10-01

    Rapid developments have occurred both in laboratory medicine and in therapeutic interventions for the management of patients with chronic myelogenous leukemia (CML). With a wide array of laboratory tests available, selecting the appropriate test for a specific diagnostic or therapeutic setting has become increasingly difficult. In this review, we first discuss, from the point of view of laboratory medicine, the advantages and disadvantages of several commonly used laboratory assays, including cytogenetics, fluorescence in situ hybridization (FISH), and qualitative and quantitative reverse transcriptase-polymerase chain reaction (RT-PCR). We then discuss, from the point of view of clinical care, the test(s) of choice for the most common clinical scenarios, including diagnosis and monitoring of the therapeutic response and minimal residual disease in patients treated with different therapies. The purpose of this review is to help clinicians and laboratory physicians select appropriate tests for the diagnosis and monitoring of CML, with the ultimate goal of improving the cost-effective usage of clinical laboratories and improving patient care. Copyright 2001 Wiley-Liss, Inc.

  5. Comparison of a standardized procedure with current laboratory practices for the detection of lupus anticoagulant in France. Working Group on Hemostasis of the Société Française de Biologie Clinique.

    PubMed

    1993-11-15

    A multicenter study involving 13 laboratories was designed to compare a common procedure for screening lupus anticoagulants (LA) to the different practices currently in use in these laboratories. The common procedure combined 3 phospholipid-dependent assays, including mixing studies and a phospholipid neutralizing test. Due to the heterogeneity of LA expression, an abnormal result in at least one of the tests was sufficient to classify a sample as positive for LA. Consecutive samples referred for LA diagnosis were evaluated in parallel by each participant and the data found using the common procedure were analyzed independently according to mutually agreed cut-offs and criteria for sample classification. Within a period of 3 months, 535 samples were included, of which 147 were judged LA positive, 29 undetermined and 359 negative by the respective laboratories using their current practice. When using the common procedure, 149 plasmas were said to be positive, 38 undetermined and 348 negative. Absolute concordance occurred for 81% of the specimen population and absolute discordance (positive versus negative) for 7%. The level of agreement between the common procedure and the current practices, assessed by kappa indexes, indicated noticeable variations in the rates of detection from laboratory to laboratory. Among the different tests used in the common procedure, regular APTT was the least sensitive (about 50% detection) but none of the other tests alone recognized more than 73% of specimens from the LA positive population. This yield increased to about 90% with any combination of 2 sensitive tests.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    PubMed

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  7. Developing a laboratory protocol for asphalt binder recovery.

    DOT National Transportation Integrated Search

    2014-10-01

    Asphalt binder extraction and recovery are common laboratory procedures used to provide material for research and quality : assurance testing. The most common methods of recovery performed today include the Abson method and the rotary evaporator : (o...

  8. [Laboratory medicine in the obligatory postgraduate clinical training system--common clinical training program in the department of laboratory medicine in our prefectural medical university hospital].

    PubMed

    Okamoto, Yasuyuki

    2003-04-01

    I propose a postgraduate common clinical training program to be provided by the department of laboratory medicine in our prefectural medical university hospital. The program has three purposes: first, mastering basic laboratory tests; second, developing the skills necessary to accurately interpret laboratory data; third, learning specific techniques in the field of laboratory medicine. For the first purpose, it is important that medical trainees perform testing of their own patients at bedside or in the central clinical laboratory. When testing at the central clinical laboratory, instruction by expert laboratory technicians is helpful. The teaching doctors in the department of laboratory medicine are asked to advise the trainees on the interpretation of data. Consultation will be received via interview or e-mail. In addition, the trainees can participate in various conferences, seminars, and meetings held at the central clinical laboratory. Finally, in order to learn specific techniques in the field of laboratory medicine, several special courses lasting a few months will be prepared. I think this program should be closely linked to the training program in internal medicine.

  9. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  10. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  11. Syphilis testing practices in the Americas.

    PubMed

    Trinh, Thuy T; Kamb, Mary L; Luu, Minh; Ham, D Cal; Perez, Freddy

    2017-09-01

    To present the findings of the Pan American Health Organization's 2014 survey on syphilis testing policies and practices in the Americas. Representatives of national/regional reference and large, lower-level laboratories from 35 member states were invited to participate. A semi-structured, electronically administered questionnaire collected data on syphilis tests, algorithms, equipment/commodities, challenges faced and basic quality assurance (QA) strategies employed (i.e. daily controls, standard operating procedures, technician training, participating in external QA programmes, on-site evaluations). The 69 participating laboratories from 30 (86%) member states included 41 (59%) national/regional reference and 28 (41%) lower-level laboratories. Common syphilis tests conducted were the rapid plasma reagin (RPR) (62% of surveyed laboratories), venereal disease research laboratory (VDRL) (54%), fluorescent treponemal antibody absorption (FTA-ABS) (41%) and Treponema pallidum haemagglutination assay (TPHA) (32%). Only three facilities reported using direct detection methods, and 28 (41% overall, 32% of lower-level facilities) used rapid tests. Most laboratories (62%) used only traditional testing algorithms (non-treponemal screening and treponemal confirmatory testing); however, 12% used only a reverse sequence algorithm (treponemal test first), and 14% employed both algorithms. Another nine (12%) laboratories conducted only one type of serologic test. Although most reference (97%) and lower-level (89%) laboratories used at least one QA strategy, only 16% reported using all five basic strategies. Commonly reported challenges were stock-outs of essential reagents or commodities (46%), limited staff training (73%) and insufficient equipment (39%). Many reference and clinical laboratories in the Americas face challenges in conducting appropriate syphilis testing and in ensuring quality of testing. © 2017 John Wiley & Sons Ltd The Pan-American Health Organization retains copyright and all other rights in the manuscript of this article as submitted for publication.

  12. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species

    USGS Publications Warehouse

    Raimondo, Sandy; Lilavois, Crystal R.; Lee, Larisa; Augspurger, Tom; Wang, Ning; Ingersoll, Christopher G.; Bauer, Candice R.; Hammer, Edward J.; Barron, Mace G.

    2016-01-01

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitivity among commonly tested mussels (Lampsilis siliquoidea, Utterbackia imbecillis, Villosa iris), commonly tested cladocerans (Daphnia magna, Ceriodaphnia dubia) and fish (Oncorhynchus mykiss, Pimephales promelas, Lepomis macrochirus). The results of these analyses indicate intra-laboratory variability for median effect concentrations (EC50) averaged about 2 fold for both life stages, while inter-laboratory variability averaged 3.6 fold for juvenile mussels and 6.3 fold for glochidia. The EC50s for juveniles and glochidia were within a factor of 2 of each other for 50% of paired records across chemicals, with juveniles more sensitive than glochidia by more than 2 fold for 33% of the comparisons made between life stages. There was a high concurrence of the sensitivity of commonly tested L. siliquoidea, U. imbecillis, and V. iris to that of other mussels. However, this concurrence decreases as the taxonomic distance of the commonly tested cladocerans and fish to mussels increases. The compiled mussel database and determination of data variability will advance risk assessments by including more robust species sensitivity distributions, interspecies correlation estimates, and availability of taxon-specific empirically derived application factors for risk assessment.

  13. EVALUATION OF MIXING ENERGY IN LABORATORY FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. The success of a test relies on replication of the conditions at sea. We used a hot wire anemometer to characterize the turbulence characteristics in the s...

  14. Misleading biochemical laboratory test results

    PubMed Central

    Nanji, Amin A.

    1984-01-01

    This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845

  15. Characterization of 107 Genomic DNA Reference Materials for CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1

    PubMed Central

    Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa

    2010-01-01

    Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555

  16. Making Sense of Fear Testing - Validating Common Behavioral Tests used in Swine

    USDA-ARS?s Scientific Manuscript database

    Tests to assess fear are commonly used in laboratory animals, such as mice and rats, when researchers wish to understand the implications of specific drugs, such as anxiolytics, or specific environments which may be used to house experimental animals. Researchers who study the welfare of livestock ...

  17. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  18. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  19. An examination of the usefulness of repeat testing practices in a large hospital clinical chemistry laboratory.

    PubMed

    Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G

    2012-01-01

    A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.

  20. Kidney function tests

    MedlinePlus

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  1. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  2. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  3. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  4. Changing resident test ordering behavior: a multilevel intervention to decrease laboratory utilization at an academic medical center.

    PubMed

    Vidyarthi, Arpana R; Hamill, Timothy; Green, Adrienne L; Rosenbluth, Glenn; Baron, Robert B

    2015-01-01

    Hospital laboratory test volume is increasing, and overutilization contributes to errors and costs. Efforts to reduce laboratory utilization have targeted aspects of ordering behavior, but few have utilized a multilevel collaborative approach. The study team partnered with residents to reduce unnecessary laboratory tests and associated costs through multilevel interventions across the academic medical center. The study team selected laboratory tests for intervention based on cost, volume, and ordering frequency (complete blood count [CBC] and CBC with differential, common electrolytes, blood enzymes, and liver function tests). Interventions were designed collaboratively with residents and targeted components of ordering behavior, including system changes, teaching, social marketing, academic detailing, financial incentives, and audit/feedback. Laboratory ordering was reduced by 8% cumulatively over 3 years, saving $2 019 000. By involving residents at every stage of the intervention and targeting multiple levels simultaneously, laboratory utilization was reduced and cost savings were sustained over 3 years. © 2014 by the American College of Medical Quality.

  5. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding System Code...

  6. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding System Code...

  7. RBC count

    MedlinePlus

    ... common measurements for results of these tests. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your health ...

  8. Test Preparation: Your Role

    MedlinePlus

    ... transport the sample from home to the lab. Examples of some common laboratory tests that require advance preparation include: Glucose tolerance, fasting, and two-hour post-prandial blood glucose tests : fasting or eating meals ...

  9. LABCON - Laboratory Job Control program

    NASA Technical Reports Server (NTRS)

    Reams, L. T.

    1969-01-01

    Computer program LABCON controls the budget system in a component test laboratory whose workload is made up from many individual budget allocations. A common denominator is applied to an incoming job, to which all effort is charged and accounted for.

  10. Terminology modeling for an enterprise laboratory orders catalog.

    PubMed

    Zhou, Li; Goldberg, Howard; Pabbathi, Deepika; Wright, Adam; Goldman, Debora S; Van Putten, Cheryl; Barley, Amanda; Rocha, Roberto A

    2009-11-14

    Laboratory test orders are used in a variety of clinical information systems at Partners HealthCare. At present, each site at Partners manages its own set of laboratory orders with locally defined codes. Our current plan is to implement an enterprise catalog, where laboratory test orders are mapped to reference terminologies and codes from different sites are mapped to each other. This paper describes the terminology modeling effort that preceded the implementation of the enterprise laboratory orders catalog. In particular, we present our experience in adapting HL7's "Common Terminology Services 2 - Upper Level Class Model" as a terminology metamodel for guiding the development of fully specified laboratory orders and related services.

  11. Terminology Modeling for an Enterprise Laboratory Orders Catalog

    PubMed Central

    Zhou, Li; Goldberg, Howard; Pabbathi, Deepika; Wright, Adam; Goldman, Debora S.; Van Putten, Cheryl; Barley, Amanda; Rocha, Roberto A.

    2009-01-01

    Laboratory test orders are used in a variety of clinical information systems at Partners HealthCare. At present, each site at Partners manages its own set of laboratory orders with locally defined codes. Our current plan is to implement an enterprise catalog, where laboratory test orders are mapped to reference terminologies and codes from different sites are mapped to each other. This paper describes the terminology modeling effort that preceded the implementation of the enterprise laboratory orders catalog. In particular, we present our experience in adapting HL7’s “Common Terminology Services 2 – Upper Level Class Model” as a terminology metamodel for guiding the development of fully specified laboratory orders and related services. PMID:20351950

  12. Critical Value Reporting at Egyptian Laboratories.

    PubMed

    Mosallam, Rasha; Ibrahim, Samaa Zenhom

    2015-06-12

    To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.

  13. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States.

    PubMed

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin

    2016-07-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.

  14. Safety validation test equipment operation

    NASA Astrophysics Data System (ADS)

    Kurosaki, Tadaaki; Watanabe, Takashi

    1992-08-01

    An overview of the activities conducted on safety validation test equipment operation for materials used for NASA manned missions is presented. Safety validation tests, such as flammability, odor, offgassing, and so forth were conducted in accordance with NASA-NHB-8060.1C using test subjects common with those used by NASA, and the equipment used were qualified for their functions and performances in accordance with NASDA-CR-99124 'Safety Validation Test Qualification Procedures.' Test procedure systems were established by preparing 'Common Procedures for Safety Validation Test' as well as test procedures for flammability, offgassing, and odor tests. The test operation organization chaired by the General Manager of the Parts and Material Laboratory of NASDA (National Space Development Agency of Japan) was established, and the test leaders and operators in the organization were qualified in accordance with the specified procedures. One-hundred-one tests had been conducted so far by the Parts and Material Laboratory according to the request submitted by the manufacturers through the Space Station Group and the Safety and Product Assurance for Manned Systems Office.

  15. Test of the Equivalence Principle in an Einstein Elevator

    NASA Technical Reports Server (NTRS)

    Shapiro, Irwin I.; Lorenzini, E. C.; Glashow, S.; Cosmo, M. L.; Cheimets, P.; Finkelstein, N.; Schneps, M.; Iafolla, V.; Nozzoli, S.

    2003-01-01

    The laboratory activity consisted in the construction of a laboratory prototype of a differential accelerometer. The laboratory prototype has been used to conduct key tests on the differential instrument. We demonstrated the ability to damp quickly transient oscillations by utilizing a resistive load in the feedback loops and then removing that load to reestablish a high quality factor of the detector. A rotating divide with tilt control was also built. This device was utilized to impart (through the Earth's gravity) common-mode perturbations to the differential accelerometer. These calibration disturbances have been used to trim the acceleration outputs of the individual proof masses in order to obtain a common-mode rejection factor better than 10(exp -4) in a sufficiently large frequency band centered at the spin frequency.

  16. Comparisons of Sediment Test Volumes for Freshwater Solid Phase Sediment Toxicity Tests

    EPA Science Inventory

    Laboratory tests with benthic macroinvertebrates are commonly used to assess the potential toxicity of contaminated sediments, and detailed standard test procedures have been developed for various species. For freshwater, two benthic organisms, Hyalella azteca and Chironomus dil...

  17. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    PubMed

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  18. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008-2010.

    PubMed

    Dimech, Wayne; Lim, Megan S C; Van Gemert, Caroline; Guy, Rebecca; Boyle, Douglas; Donovan, Basil; Hellard, Margaret

    2014-06-12

    Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group.

  19. Analysis of laboratory testing results collected in an enhanced chlamydia surveillance system in Australia, 2008–2010

    PubMed Central

    2014-01-01

    Background Chlamydial infection is the most common notifiable disease in Australia, Europe and the US. Australian notifications of chlamydia rose four-fold from 20,274 cases in 2002 to 80,846 cases in 2011; the majority of cases were among young people aged less than 29 years. Along with test positivity rates, an understanding of the number of tests performed and the demographics of individuals being tested are key epidemiological indicators. The ACCESS Laboratory Network was established in 2008 to address this issue. Methods The ACCESS Laboratory Network collected chlamydia testing data from 15 laboratories around Australia over a three-year period using data extraction software. All chlamydia testing data from participating laboratories were extracted from the laboratory information system; patient identifiers converted to a unique, non-reversible code and de-identified data sent to a single database. Analysis of data by anatomical site included all specimens, but in age and sex specific analysis, only one testing episode was counted. Results From 2008 to 2010 a total of 628,295 chlamydia tests were referred to the 15 laboratories. Of the 592,626 individual episodes presenting for testing, 70% were from female and 30% from male patients. In female patients, chlamydia positivity rate was 6.4% overall; the highest rate in 14 year olds (14.3%). In male patients, the chlamydia positivity rate was 9.4% overall; the highest in 19 year olds (16.5%). The most common sample type was urine (57%). In 3.2% of testing episodes, multiple anatomical sites were sampled. Urethral swabs gave the highest positivity rate for all anatomical sites in both female (7.7%) and male patients (14%), followed by urine (7.6% and 9.4%, respectively) and eye (6.3% and 7.9%, respectively). Conclusions The ACCESS Laboratory Network data are unique in both number and scope and are representative of chlamydia testing in both general practice and high-risk clinics. The findings from these data highlight much lower levels of testing in young people aged 20 years or less; in particular female patients aged less than 16 years, despite being the group with the highest positivity rate. Strategies are needed to increase the uptake of testing in this high-risk group. PMID:24920016

  20. Routine admission laboratory testing for general medical patients.

    PubMed

    Hubbell, F A; Frye, E B; Akin, B V; Rucker, L

    1988-06-01

    We evaluated the usefulness of commonly ordered routine admission laboratory tests in 301 patients admitted consecutively to the internal medicine wards of a university teaching hospital. Using a consensus analysis approach, three Department of Medicine faculty members reviewed the charts of admitted patients to determine the impact of the test results on patient care. The evaluated tests were the urinalysis, hematocrit, white blood cell count, platelet count, six-factor automated multiple analysis (serum sodium, potassium, chloride, bicarbonate, glucose, and blood urea nitrogen), prothrombin time, partial thromboplastin time, chest x-ray, and electrocardiogram. Forty-five percent of the 3,684 tests were ordered for patients without recognizable medical indications. Twelve percent of these routine tests were abnormal, 5% led to additional laboratory testing, but only 0.5% led to change in the treatment of patients. We conclude that the impact of routine admission laboratory testing on patient care is very small and that there is little justification for ordering tests solely because of hospital admission.

  1. Construction of a dictionary of laboratory tests mapped to LOINC at AP-HP.

    PubMed

    Cormont, Sylvie; Buemi, Antoine; Horeau, Thierry; Zweigenbaum, Pierre; Lepage, Eric

    2008-11-06

    We report on the ongoing process implemented at Assistance Publique-Hôpitaux de Paris (AP-HP), the largest hospital system in Europe, to build a common reference for laboratory tests in French with LOINC mappings. At the time of writing, it contained 24,000 tests, covering all fields of biology, in use in 19 AP-HP hospitals, 30% of which had a mapping to LOINC with a peak of over 60% in biochemistry.

  2. Distant testing in laboratory hematology and flow cytometry--the Indian experience.

    PubMed

    Das Gupta, Amar

    2012-06-01

    Outsourcing or sending out of patients' samples to other laboratories for hematologic investigations is a common practice these days. Preanalytic variables that alter cellular parameters and levels of analytes in transit and on storage can significantly and adversely affect interpretation of test results in hematology. Awareness of these changes is necessary to avoid misinterpretation of results that in turn could influence medical management decisions.

  3. Clinical laboratory billing: superfluous requirements without justification?

    PubMed

    Stadler, Stephen

    2004-01-01

    Congress occasionally passes new laws that affect how clinical laboratories handle test orders from physicians and, subsequently, process the billing for tests. Once a bill is signed into law, it is forwarded to administrative agencies, which draft regulations and administrative procedures, under which the intentions of Congress are carried out. In the case of laboratory test ordering and billing, the Centers for Medicare and Medicaid Services (CMS) has the greatest influence over how these regulations and procedures are defined. Unfortunately, in many cases, billing rules have been promulgated in ways that create the need for hospitals and commercial laboratories to expend huge sums of money to bill within the confines of the administrative rules; cause clinical laboratories to suffer from omissions and mistakes of other parties who are part of the patient care process but are not accountable for the billing information they provide to laboratories; and, frankly, in some respects, simply defy common sense.

  4. Final Rule for Procedures for Testing Highway and Nonroad Engines and Omnibus Technical Amendments

    EPA Pesticide Factsheets

    This common set of test requirements is intended to streamline laboratory efforts for EPA and industry and to form the basis for internationally harmonized test procedures for nearly all categories of engines.

  5. Value of laboratory tests in employer-sponsored health risk assessments for newly identifying health conditions: analysis of 52,270 participants.

    PubMed

    Kaufman, Harvey W; Williams, Fred R; Odeh, Mouneer A

    2011-01-01

    Employer-sponsored health risk assessments (HRA) may include laboratory tests to provide evidence of disease and disease risks for common medical conditions. We evaluated the ability of HRA-laboratory testing to provide new disease-risk information to participants. We performed a cross-sectional analysis of HRA-laboratory results for participating adult employees and their eligible spouses or their domestic partners, focusing on three common health conditions: hyperlipidemia, diabetes mellitus, and chronic kidney disease. HRA with laboratory results of 52,270 first-time participants were analyzed. Nearly all participants had access to health insurance coverage. Twenty-four percent (12,392) self-reported one or more of these medical conditions: 21.1% (11,017) self-identified as having hyperlipidemia, 4.7% (2,479) self-identified as having diabetes, and 0.7% (352) self-identified as having chronic kidney disease. Overall, 36% (n = 18,540) of participants had laboratory evidence of at least one medical condition newly identified: 30.7% (16,032) had laboratory evidence of hyperlipidemia identified, 1.9% (984) had laboratory evidence of diabetes identified, and 5.5% (2,866) had laboratory evidence of chronic kidney disease identified. Of all participants with evidence of hyperlipidemia 59% (16,030 of 27,047), were newly identified through the HRA. Among those with evidence of diabetes 28% (984 of 3,463) were newly identified. The highest rate of newly identified disease risk was for chronic kidney disease: 89% (2,866 of 3,218) of participants with evidence of this condition had not self-reported it. Men (39%) were more likely than women (33%) to have at least one newly identified condition (p<0.0001). Among men, lower levels of educational achievement were associated with modestly higher rates of newly identified disease risk (p<0.0001); the association with educational achievement among women was unclear. Even among the youngest age range (20 to 29 year olds), nearly 1 in 4 participants (24%) had a newly identified risk for disease. These results support the important role of employer-sponsored laboratory testing as an integral element of HRA for identifying evidence of previously undiagnosed common medical conditions in individuals of all working age ranges, regardless of educational level and gender.

  6. Sequential infection with common pathogens promotes human-like immune gene expression and altered vaccine response

    PubMed Central

    Reese, Tiffany A.; Bi, Kevin; Kambal, Amal; Filali-Mouhim, Ali; Beura, Lalit K.; Bürger, Matheus C.; Pulendran, Bali; Sekaly, Rafick; Jameson, Stephen C.; Masopust, David; Haining, W. Nicholas; Virgin, Herbert W.

    2016-01-01

    Summary Immune responses differ between laboratory mice and humans. Chronic infection with viruses and parasites are common in humans, but are absent in laboratory mice, and thus represent potential contributors to inter-species differences in immunity. To test this, we sequentially infected laboratory mice with herpesviruses, influenza, and an intestinal helminth, and compared their blood immune signatures to mock-infected mice before and after vaccination against Yellow Fever Virus (YFV-17D). Sequential infection altered pre- and post-vaccination gene expression, cytokines, and antibodies in blood. Sequential pathogen exposure induced gene signatures that recapitulated those seen in blood from pet store-raised versus laboratory mice, and adult versus cord blood in humans. Therefore basal and vaccine-induced murine immune responses are altered by infection with agents common outside of barrier facilities. This raises the possibility that we can improve mouse models of vaccination and immunity by selective microbial exposure of laboratory animals to mimic that of humans. PMID:27107939

  7. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    PubMed

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  8. International Seed Testing Association List of stabilized plant names, edition 6

    USDA-ARS?s Scientific Manuscript database

    Seed-testing laboratories determine the quality of seed lots in national and international seed commerce. Those services most commonly requested include purity analysis, noxious-weed seed detection, and viability tests. Rigorous procedures for performing various tests on specific crops have been est...

  9. FEASIBILITY OF HYDRAULIC FRACTURING OF SOILS TO IMPROVE REMEDIAL ACTIONS

    EPA Science Inventory

    Hydraulic fracturing, a technique commonly used to increase the yields of oil wells, could improve the effectiveness of several methods of in situ remediation. This project consisted of laboratory and field tests in which hydraulic fractures were created in soil. Laboratory te...

  10. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  11. Use, location, and timeliness of clinical microbiology testing in Georgia for select infectious diseases.

    PubMed

    Brzozowski, Amanda K; Silk, Benjamin J; Berkelman, Ruth L; Loveys, Deborah A; Caliendo, Angela M

    2012-01-01

    Although clinical microbiology testing facilitates both public health surveillance of infectious diseases and patient care, research on testing patterns is scant. We surveyed hospital laboratories in Georgia to assess their diagnostic testing practices. Using e-mail, all directors of hospital laboratories in Georgia were invited to participate. The survey focused on timing and location of diagnostic testing in 2006 for 6 reportable diseases: giardiasis, legionellosis, meningococcal disease, pertussis, Rocky Mountain spotted fever, and West Nile virus disease. Of 141 laboratories, 62 (44%) responded to the survey. Hospitals varied widely in their use of diagnostic testing in 2006, with 95.1% testing for meningococcal disease, but only 66.1% and 63.3% testing for legionellosis and West Nile virus disease, respectively. Most laboratories (91%) performed gram stain/culture to diagnose meningococcal disease in-house and 23% performed ova and parasite panels for giardiasis were conducted in-house. Fewer than 11% of laboratories performed in-house testing for the remaining diseases. Laboratories affiliated with small hospitals (≤100 beds) were more likely to send specimens for outside testing compared with laboratories associated with large hospitals (>250 beds). Median turnaround time for ova and parasite panel testing for giardiasis was significantly shorter for in-house testing (1.0 days) than within-system (2.25 days) or outside laboratory (3.0 days) testing (P = .0003). No laboratories reported in-house testing for meningococcal disease, pertussis, or Rocky Mountain spotted fever using polymerase chain reaction. Many hospitals did not order diagnostic tests for important infectious diseases during 2006, even for relatively common diseases. In addition, hospital laboratories were unlikely to perform diagnostic testing in-house; sending specimens to an outside laboratory may result in substantial delays in receiving results. These unsettling findings have adverse implications for both patient care and public health surveillance; they indicate an immediate need to study nationally the use and timeliness of clinical microbiologic testing.

  12. Laboratory Assays in Evaluation of Lynch Syndrome in Patients with Endometrial Carcinoma.

    PubMed

    Djordjevic, Bojana; Broaddus, Russell R

    2016-06-01

    This article reviews the main tissue testing modalities for Lynch Syndrome in the pathology laboratory, such as immunohistochemistry and PCR based analyses, and discusses their routine application, interpretation pitfalls, and troubleshooting of common technical performance issues. Discrepancies between laboratory and genetic testing may arise, and are examined in the context of the complexity of molecular abnormalities associated with Lynch Syndrome. The merits of targeted versus universal screening in a changing healthcare climate are addressed. In the absence of comprehensive screening programs, specific tumor topography and histological features that may prompt pathologist-initiated molecular tumor testing are outlined. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Analysis of on-line clinical laboratory manuals and practical recommendations.

    PubMed

    Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron

    2004-04-01

    On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.

  14. Laboratory Safety Monitoring of Chronic Medications in Ambulatory Care Settings

    PubMed Central

    Hurley, Judith S; Roberts, Melissa; Solberg, Leif I; Gunter, Margaret J; Nelson, Winnie W; Young, Linda; Frost, Floyd J

    2005-01-01

    OBJECTIVE To evaluate laboratory safety monitoring in patients taking selected chronic prescription drugs. DESIGN Retrospective study using 1999–2001 claims data to calculate rates of missed laboratory tests (potential laboratory monitoring errors). Eleven drugs/drug groups and 64 laboratory tests were evaluated. SETTING Two staff/network model health maintenance organizations. PATIENTS Continuously enrolled health plan members age≥19 years taking ≥1 chronic medications. MEASUREMENTS AND MAIN RESULTS Among patients taking chronic medications (N=29,823 in 1999, N=32,423 in 2000, and N=36,811 in 2001), 47.1% in 1999, 45.0% in 2000, and 44.0% in 2001 did not receive ≥1 test recommended for safety monitoring. Taking into account that patients were sometimes missing more than 1 test for a given drug and that patients were frequently taking multiple drugs, the rate of all potential laboratory monitoring errors was 849/1,000 patients/year in 1999, 810/1,000 patients/year in 2000, and 797/1,000 patients/year in 2001. Rates of potential laboratory monitoring errors varied considerably across individual drugs and laboratory tests. CONCLUSIONS Lapses in laboratory monitoring of patients taking selected chronic medications were common. Further research is needed to determine whether, and to what extent, this failure to monitor patients is associated with adverse clinical outcomes. PMID:15857489

  15. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States

    PubMed Central

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul

    2016-01-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832

  16. An audit of Cryptosporidium and Giardia detection in Scottish National Health Service Diagnostic Microbiology Laboratories.

    PubMed

    Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L

    2017-06-01

    Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.

  17. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  18. Asphalt mixture performance characterization using small-scale cylindrical specimens.

    DOT National Transportation Integrated Search

    2015-06-01

    The results of dynamic modulus testing have become one of the primarily used performance criteria to evaluate the : laboratory properties of asphalt mixtures. This test is commonly conducted to characterize asphalt mixtures mechanistically : using an...

  19. TECHNIQUES TO DETERMINE A COMPANY'S ABILITY TO CONDUCT A QUALITY STACK TEST

    EPA Science Inventory

    Techniques to determine a testing company's ability to conduct a quality stack test for compliance or process engineering purposes are presented. The document has four sections. The first identifies characteristics commonly associated with laboratories that have a history of perf...

  20. Standardization of Terminology in Laboratory Medicine II

    PubMed Central

    Lee, Kap No; Yoon, Jong-Hyun; Min, Won Ki; Lim, Hwan Sub; Song, Junghan; Chae, Seok Lae; Jang, Seongsoo; Ki, Chang-Seok; Bae, Sook Young; Kim, Jang Su; Kwon, Jung-Ah; Lee, Chang Kyu

    2008-01-01

    Standardization of medical terminology is essential in data transmission between health care institutes and in maximizing the benefits of information technology. The purpose of this study was to standardize medical terms for laboratory observations. During the second year of the study, a standard database of concept names for laboratory terms that covered those used in tertiary health care institutes and reference laboratories was developed. The laboratory terms in the Logical Observation Identifier Names and Codes (LOINC) database were adopted and matched with the electronic data interchange (EDI) codes in Korea. A public hearing and a workshop for clinical pathologists were held to collect the opinions of experts. The Korean standard laboratory terminology database containing six axial concept names, components, property, time aspect, system (specimen), scale type, and method type, was established for 29,340 test observations. Short names and mapping tables for EDI codes and UMLS were added. Synonym tables were prepared to help match concept names to common terms used in the fields. We herein described the Korean standard laboratory terminology database for test names, result description terms, and result units encompassing most of the laboratory tests in Korea. PMID:18756062

  1. Permeation of fingerprints through laboratory gloves.

    PubMed

    Willinski, G

    1980-07-01

    Repeated controlled tests have shown that impressions from laboratory gloves will print onto optical components in 20 to 40 min and, in some cases, sooner. Careful testing demonstrated that palmar sweat passed through the glove material; the problem was not that gloves conform to the friction ridges of the fingers and then transfer some contaminant. The problem can be alleviated to a great extent by wearing thin cotton gloves like those commonly used in the film industry.

  2. Survey of laboratory practices for diagnosis of fungal infection in seven Asian countries: An Asia Fungal Working Group (AFWG) initiative.

    PubMed

    Chindamporn, Ariya; Chakrabarti, Arunaloke; Li, Ruoyu; Sun, Pei-Lun; Tan, Ban-Hock; Chua, Mitzi; Wahyuningsih, Retno; Patel, Atul; Liu, Zhengyin; Chen, Yee-Chun; Chayakulkeeree, Methee

    2018-06-01

    An online survey of mycology laboratories in seven Asian countries was conducted to assess the status, competence, and services available. Country representatives from the Asia Fungal Working Group (AFWG) contacted as many laboratories performing mycology diagnosis as possible in their respective countries, requesting that the laboratory heads complete the online survey. In total, 241 laboratories responded, including 71 in China, 104 in India, 11 in Indonesia, 26 in the Philippines, four in Singapore, 18 in Taiwan, and seven in Thailand. Overall, 129/241 (53.5%) surveyed mycology laboratories operate as separate designated mycology laboratories, 75/241 (31.1%) conduct regular formal staff training, 103/241 (42.7%) are accredited, and 88/157 (56.1%) participate in external quality assurance scheme (EQAS) programs. Microscopy and culture methods are available in nearly all laboratories, although few perform DNA sequencing (37/219; 16.9%) or use matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF MS) (27/219; 12.3%) for isolate identification. Antifungal susceptibility testing is performed in 142/241 (58.9%) laboratories, mainly for yeasts. The most commonly performed nonculture diagnostic is cryptococcal antigen testing (66 laboratories), followed by galactomannan testing (55), polymerase chain reaction (PCR) diagnosis (37), and beta-D-glucan testing (24). Therapeutic drug monitoring is conducted in 21 laboratories. There is almost no access to advanced diagnostic tests, like galactomannan, β-D-glucan, and PCR, in the surveyed laboratories in Indonesia, the Philippines, and Thailand. These results highlight the need for development of quality laboratories, accreditation and training of manpower in existing laboratories, and access to advanced non-culture-based diagnostic tests to facilitate the diagnosis of fungal infections in Asia.

  3. A cost-effective interdisciplinary approach to microbiologic send-out test use.

    PubMed

    Aesif, Scott W; Parenti, David M; Lesky, Linda; Keiser, John F

    2015-02-01

    Use of reference laboratories for selected laboratory testing (send-out tests) represents a significant source of laboratory costs. As the use of more complex molecular analyses becomes common in the United States, strategies to reduce costs in the clinical laboratory must evolve in order to provide high-value, cost-effective medicine. To report a strategy that employs clinical pathology house staff and key hospital clinicians in the effective use of microbiologic send-out testing. The George Washington University Hospital is a 370-bed academic hospital in Washington, DC. In 2012 all requisitions for microbiologic send-out tests were screened by the clinical pathology house staff prior to final dispensation. Tests with questionable utility were brought to the attention of ordering clinicians through the use of interdisciplinary rounds and direct face-to-face consultation. Screening resulted in a cancellation rate of 38% of send-out tests, with proportional cost savings. Nucleic acid tests represented most of the tests screened and the largest percentage of cost saved through screening. Following consultation, requested send-out tests were most often canceled because of a lack of clinical indication. Direct face-to-face consultation with ordering physicians is an effective, interdisciplinary approach to managing the use of send-out testing in the microbiology laboratory.

  4. Laboratory Testing Protocols for Heparin-Induced Thrombocytopenia (HIT) Testing.

    PubMed

    Lau, Kun Kan Edwin; Mohammed, Soma; Pasalic, Leonardo; Favaloro, Emmanuel J

    2017-01-01

    Heparin-induced thrombocytopenia (HIT) represents a significant high morbidity complication of heparin therapy. The clinicopathological diagnosis of HIT remains challenging for many reasons; thus, laboratory testing represents an important component of an accurate diagnosis. Although there are many assays available to assess HIT, these essentially fall into two categories-(a) immunological assays, and (b) functional assays. The current chapter presents protocols for several HIT assays, being those that are most commonly performed in laboratory practice and have the widest geographic distribution. These comprise a manual lateral flow-based system (STiC), a fully automated latex immunoturbidimetric assay, a fully automated chemiluminescent assay (CLIA), light transmission aggregation (LTA), and whole blood aggregation (Multiplate).

  5. Laboratory-based testing to evaluate abuse-deterrent formulations and satisfy the Food and Drug Administration's recommendation for Category 1 Testing.

    PubMed

    Altomare, Christopher; Kinzler, Eric R; Buchhalter, August R; Cone, Edward J; Costantino, Anthony

    The US Food and Drug Administration (FDA) considers the development of abuse-deterrent formulations of solid oral dosage forms a public health priority and has outlined a series of premarket studies that should be performed prior to submitting an application to the Agency. Category 1 studies are performed to characterize whether the abuse-deterrent properties of a new formulation can be easily defeated. Study protocols are designed to evaluate common abuse patterns of prescription medications as well as more advanced methods that have been reported on drug abuse websites and forums. Because FDA believes Category 1 testing should fully characterize the abuse-deterrent characteristics of an investigational formulation, Category 1 testing is time consuming and requires specialized laboratory resources as well as advanced knowledge of prescription medication abuse. Recent Advisory Committee meetings at FDA have shown that Category 1 tests play a critical role in FDA's evaluation of an investigational formulation. In this article, we will provide a general overview of the methods of manipulation and routes of administration commonly utilized by prescription drug abusers, how those methods and routes are evaluated in a laboratory setting, and discuss data intake, analysis, and reporting to satisfy FDA's Category 1 testing requirements.

  6. The quality of laboratory aspects of troponin testing in clinical practice guidelines and consensus documents needs to be improved.

    PubMed

    Aakre, Kristin M; Langlois, Michel R; Barth, Julian H; Misra, Shivani; Watine, Joseph; Oosterhuis, Wytze P

    2014-11-01

    The European Federation of Laboratory Medicine (EFLM) and the Union of European Medical Specialists (UEMS) joint Working Group on guidelines recently proposed a checklist to help standardize the description of laboratory investigations in clinical practice guidelines (CPG). Nine CPGs or consensus documents published from 2011 to 2013 describing the investigation of chest pain, diagnosis of acute coronary syndrome, or myocardial infarction were evaluated against the published checklist. Clinical use of troponin analysis are commonly dealt with but the publications present variable, vague and sometimes conflicting information regarding this laboratory test being very much relied on upon making a diagnosis of acute coronary syndrome. Most of the laboratory related checklist items are not considered or need to be updated e.g. suggested analytical quality goals are not applicable for the high sensitive assays and important interferences that may lead to false positive or negative diagnoses are commonly not mentioned. The current paper sums up important analytical and biological issues related to troponin assays and gives suggestions for analytical quality goals that could be included in CPG's. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Reducing Missed Laboratory Results: Defining Temporal Responsibility, Generating User Interfaces for Test Process Tracking, and Retrospective Analyses to Identify Problems

    PubMed Central

    Tarkan, Sureyya; Plaisant, Catherine; Shneiderman, Ben; Hettinger, A. Zachary

    2011-01-01

    Researchers have conducted numerous case studies reporting the details on how laboratory test results of patients were missed by the ordering medical providers. Given the importance of timely test results in an outpatient setting, there is limited discussion of electronic versions of test result management tools to help clinicians and medical staff with this complex process. This paper presents three ideas to reduce missed results with a system that facilitates tracking laboratory tests from order to completion as well as during follow-up: (1) define a workflow management model that clarifies responsible agents and associated time frame, (2) generate a user interface for tracking that could eventually be integrated into current electronic health record (EHR) systems, (3) help identify common problems in past orders through retrospective analyses. PMID:22195201

  8. Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.

    PubMed

    Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H

    2018-05-13

    Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common challenges included concerns over POCT accuracy (32%), and technical barriers (29%). In the study ED, implementation of POCT was associated with a reduction in time to test result for both troponin and chemistry. Local staff felt that faster time to test result improved quality of care; however, concerns were raised with POCT accuracy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    PubMed Central

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family physicians. Approaches to ensuring more rational testing are needed. PMID:29146654

  10. Performance Analysis of Saturated Induction Motors by Virtual Tests

    ERIC Educational Resources Information Center

    Ojaghi, M.; Faiz, J.; Kazemi, M.; Rezaei, M.

    2012-01-01

    Many undergraduate-level electrical machines textbooks give detailed treatments of the performance of induction motors. Students can deepen this understanding of motor performance by performing the appropriate practical work in laboratories or in simulation using proper software packages. This paper considers various common and less-common tests…

  11. Common variations in the pretest environment influence genotypic comparisons in models of anxiety.

    PubMed

    Izídio, G S; Lopes, D M; Spricigo, L; Ramos, A

    2005-10-01

    The behavioral characterization of rodent strains in different studies and laboratories can provide unreplicable results even when genotypes are kept constant and environmental control is maximized. In the present study, the influence of common laboratory environmental variables and their interaction with genotype on the results of behavioral tests of anxiety/emotionality were investigated. To this end, the inbred rat strains Lewis (LEW) and spontaneously hypertensive rats (SHR), which are known to differ for numerous emotionality-related behaviors, were tested in the open field (OF), elevated plus maze (EPM) and black/white box (BWB), while three environmental factors were systematically controlled and analyzed: (1) the experimenter handling the animal (familiar or unfamiliar); (2) the position of the home cage (top or bottom shelf of the rack) and (3) the behavioral state of the animal immediately before the test (arousal or rest). Experimenter familiarity did not alter the behavior of rats in the OF. Cage position, on the other hand, influenced the behavior in the OF and BWB, with rats housed in top cages appearing less anxious than those housed in the bottom. In the BWB (but not in the OF), these effects were genotype dependent. Finally, the behavioral state of the animals prior to testing altered the results of the EPM in a strain-dependent manner, with some anxiety-related genotypic differences being found only among rats that were aroused in their home cages. This study showed that common variations in the laboratory environment interact with genotype in behavioral tests of anxiety/emotionality. Recognizing and understanding such variations can help in the design of more effective experiments.

  12. Field relevance of a suite of rollover tests to real-world crashes and injuries.

    PubMed

    Parenteau, Chantal S; Viano, David C; Shah, Minoo; Gopal, Madana; Davies, John; Nichols, David; Broden, Johan

    2003-01-01

    The objective of this study was to assess the distribution of rollover accidents occurring in the field and to compare the vehicle kinematics in the predominant field crash modes with available laboratory tests. For this purpose, US accident data were analyzed to identify types and circumstances for vehicle rollovers. Rollovers were most commonly induced when the lateral motion of the vehicle was suddenly slowed or stopped. This type of rollover mechanism is referred to as "trip-over". Trip-overs accounted for 57% of passenger car and 51% of light truck vehicle (LTV) rollovers. More than 90% of trip-overs were initiated by ground contact. Fall-overs were the second most common rollover type, accounting for 13% of passenger car and 15% of LTV rollovers. Bounce-overs only accounted for 8% of both passenger car and LTV rollovers. The FMVSS 208 dolly and the ADAC corkscrew rollover tests are well-known laboratory tests, but do not simulate many of the real-world rollovers. Three additional tests have been devised to more fully address the field relevant conditions identified in this study. To do so, assumptions were made and adding the new laboratory tests (soil-trip, curb-trip and ditch fall-over) increases representativeness to 83% of passenger car and 75% of LTV rollovers reported in the field. Accident data were also used to identify injuries in belted drivers so the information could later be used to better understand occupant kinematics in various roll conditions. The injury distribution for belted/non-ejected drivers was assessed for trip-over, fall-over and bounce-over accidents. Serious injuries (AIS 3+) were most common to the head and thorax, in particular for bounce-overs. Head injuries occurred from contact with the roof, pillar and the interior, while thoracic injuries resulted from contact with the interior and steering wheel assembly. Field data are useful in the development of laboratory test conditions for rollovers as it provides insights on the significance of various rollover types, understanding of injury biomechanics, guidance for future testing and inputs for mathematical modeling.

  13. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    PubMed

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  14. Lime, Fertilizer Cottonwood Tests

    Treesearch

    B. G. Blackmon; W. M. Broadfoot

    1969-01-01

    As eastern cottonwood is cut increasingly for pulp and other wood products, efforts to boost its production in Mississippi are growing. To learn more about fertilizer requirements of the species, the Southern Hardwoods Laboratory at Stoneville recently tested four common bottomland soils in which cottonwood grows.

  15. Common, yet elusive: a case of severe anion gap acidosis.

    PubMed

    Agrawal, Akanksha; Kishlyansky, Marina; Biso, Sylvia; Patnaik, Soumya; Punjabi, Chitra

    2017-09-01

    Acid-base disturbances are common occurrence in hospitalized patients with life threatening complications. 5-oxoproline has been increasingly recognized as cause of high anion gap metabolic acidosis (AGMA) in association with chronic acetaminophen use. However, laboratory workup for it are not widely available. We report case of 56-year-old female with severe AGMA not attributable to ketoacidosis, lactic acidosis or toxic ingestion. History was significant for chronic acetaminophen use, and laboratory workup negative for all frequent causes of AGMA. Given history and clinical presentation, our suspicion for 5-oxoproline toxicity was high. Our patient required emergent hemodialysis and subsequently improved clinically. With an increasing awareness of the uncommon causes of high AGMA, tests should be more readily available to detect their presence. Physicians should be more vigilant of underdiagnosed causes of AGMA if the presentation and laboratory values do not reflect a common cause, as definitive treatment may vary based on the offending agent.

  16. Larger differences in utilization of rarely requested tests in primary care in Spain.

    PubMed

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-01-01

    The study was performed to compare and analyze the inter-departmental variability in the request of rarely requested laboratory tests in primary care, as opposed to other more common and highly requested tests. Data from production statistics for the year 2012 from 76 Spanish laboratories was used. The number of antinuclear antibodies, antistreptolysin O, creatinine, cyclic citrullinated peptide antibodies, deaminated peptide gliadine IgA antibodies, glucose, protein electrophoresis, rheumatoid factor, transglutaminase IgA antibodies, urinalysis and uric acid tests requested was collected. The number of test requests per 1000 inhabitants was calculated. In order to explore the variability the coefficient of quartile dispersion was calculated. The smallest variation was seen for creatinine, glucose, uric acid and urinalysis; the most requested tests. The tests that were least requested showed the greatest variability. Our study shows through a very simplified approach, in a population close to twenty million inhabitants, how in primary care, the variability in the request of laboratory tests is inversely proportional to the request rate.

  17. Test-enhanced learning: the potential for testing to promote greater learning in undergraduate science courses.

    PubMed

    Brame, Cynthia J; Biel, Rachel

    2015-01-01

    Testing within the science classroom is commonly used for both formative and summative assessment purposes to let the student and the instructor gauge progress toward learning goals. Research within cognitive science suggests, however, that testing can also be a learning event. We present summaries of studies that suggest that repeated retrieval can enhance long-term learning in a laboratory setting; various testing formats can promote learning; feedback enhances the benefits of testing; testing can potentiate further study; and benefits of testing are not limited to rote memory. Most of these studies were performed in a laboratory environment, so we also present summaries of experiments suggesting that the benefits of testing can extend to the classroom. Finally, we suggest opportunities that these observations raise for the classroom and for further research. © 2015 C. J. Brame and R. Biel. CBE—Life Sciences Education © 2015 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  18. Laboratory errors and patient safety.

    PubMed

    Miligy, Dawlat A

    2015-01-01

    Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that evaluated the encountered laboratory errors and launch the great need for universal standardization and bench marking measures to control the laboratory work.

  19. Investigation of the applicability of intrusion technology to estimate the resilient modulus of subgrade soil.

    DOT National Transportation Integrated Search

    2000-04-01

    An innovative and simple approach is presented for estimation of the resilient modulus of subgrade soils utilizing the cone penetration test. Field and laboratory testing programs were carried out at seven sites that comprise three common soil types ...

  20. Seeking excellence: An evaluation of 235 international laboratories conducting water isotope analyses by isotope-ratio and laser-absorption spectrometry.

    PubMed

    Wassenaar, L I; Terzer-Wassmuth, S; Douence, C; Araguas-Araguas, L; Aggarwal, P K; Coplen, T B

    2018-03-15

    Water stable isotope ratios (δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected. Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1-2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Seeking excellence: An evaluation of 235 international laboratories conducting water isotope analyses by isotope-ratio and laser-absorption spectrometry

    USGS Publications Warehouse

    Wassenaar, L. I.; Terzer-Wassmuth, S.; Douence, C.; Araguas-Araguas, L.; Aggarwal, P. K.; Coplen, Tyler B.

    2018-01-01

    RationaleWater stable isotope ratios (δ2H and δ18O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test.MethodsEight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ-range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies.ResultsFor the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ18O and δ2H, respectively; ~27 % produced unacceptable results. Top performance for δ18O values was dominated by dual-inlet IRMS laboratories; top performance for δ2H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ-values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ-values were unaffected.ConclusionsAnalysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d-excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.

  2. Evaluation of the river die-away biodegradation test

    USGS Publications Warehouse

    Wylie, Glenn D.; Jones, John R.; Johnson, B. Thomas

    1982-01-01

    The reliability of the river die-away (RDA) test for establishing the biodegradability of chemicals was assessed. Reproducibility of biodegradation in the RDA test was analyzed under conditions in which the test is commonly done. Biodegradation results were not reproducible for di-2-ethylexyl phthalate (DEHP) and phthalic acid in replicated RDA tests using Missouri River water. Chemical and biological changes during the RDA tests probably reflected relative laboratory conditions. Initial suspended solids and subsequent DEHP biodegradation were directly related. Interpretation of RDA test results is enhanced by replicating experiments and comparing biodegradation of the test compound with a compound whose degradation properties are known. However, biodegradation measured with the RDA test is too variable and too dependent on laboratory treatment of samples to apply results directly to the aquatic environment.

  3. Quality Assurance in Clinical Chemistry: A Touch of Statistics and A Lot of Common Sense

    PubMed Central

    2016-01-01

    Summary Working in laboratories of clinical chemistry, we risk feeling that our personal contribution to quality is small and that statistical models and manufacturers play the major roles. It is seldom sufficiently acknowledged that personal knowledge, skills and common sense are crucial for quality assurance in the interest of patients. The employees, environment and procedures inherent to the laboratory including its interactions with the clients are crucial for the overall result of the total testing chain. As the measurement systems, reagents and procedures are gradually improved, work on the preanalytical, postanalytical and clinical phases is likely to pay the most substantial dividends in accomplishing further quality improvements. This means changing attitudes and behaviour, especially of the users of the laboratory. It requires understanding people and how to engage them in joint improvement processes. We need to use our knowledge and common sense expanded with new skills e.g. from the humanities, management, business and change sciences in order to bring this about together with the users of the laboratory. PMID:28356868

  4. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  5. Modifying Foods and Feeding Regimes to Optimize the Performance of Hyalella azteca during Chronic Toxicity Tests

    EPA Science Inventory

    The amphipod Hyalella azteca is commonly used to assess the toxicity of sediments and waters. However, laboratories have reported varying success in maintaining healthy cultures and in obtaining consistent growth and reproduction (where applicable), especially during tests...

  6. What Food and Feeding Rates are Optimum for the Chironomus dilutus Sediment Toxicity Test Method?

    EPA Science Inventory

    Laboratory tests with benthic macroinvertebrates are commonly used to assess the toxicity of both contaminated sediments and individual chemicals. Among the standard procedures for benthic macroinvertebrates are 10-d, 20-d, and life cycle exposures using the midge, Chironomus ...

  7. Utilization of stat test priority in the clinical laboratory: a College of American Pathologists q-probes study of 52 institutions.

    PubMed

    Volmar, Keith E; Wilkinson, David S; Wagar, Elizabeth A; Lehman, Christopher M

    2013-02-01

    Utilization of stat testing priority is a balance between safe, efficient patient management and resource expenditure. To determine the rate of stat testing, compare rates among institutions, and determine the distribution of turnaround time expectations for different turnaround time priorities. During a 7-day period, participants prospectively determined the total number of chemistry, hematology, and coagulation billable tests from inpatients and emergency department patients. Among these, the total numbers of billable tests performed stat were identified. Laboratories also reported the levels of test priority they offered and turnaround expectations for each level of test priority. Fifty institutions submitted data for the study, with 2 additional participants submitting partial results. Participants identified 639 589 chemistry, hematology, and coagulation billable tests, with 229 896 (35.9%) performed stat. The stat rate varied from 21.3% at the 10th percentile to 55.4% at the 90th percentile, with a median of 37.0% of participants' tests performed stat. Laboratories include a mean of 206 tests in chemistry, hematology, and coagulation test menus, with 67% of these tests offered stat. The fraction of the test menu offered stat varied from 29.0% at the 10th percentile to 97.8% at the 90th percentile, with a median of 73.3% of tests on the menu offered stat. The most common number of testing priorities offered by participating laboratories was 3 (44.2%). Among the 52 participating laboratories, the median stat testing rate was 37.0% and a median 73.3% of the test menu was offered stat.

  8. An Ibero-American inter-laboratory trial to evaluate serological tests for the detection of anti-Neospora caninum antibodies in cattle.

    PubMed

    Campero, Lucía M; Moreno-Gonzalo, Javier; Venturini, María C; Moré, Gastón; Dellarupe, Andrea; Rambeaud, Magdalena; Echaide, Ignacio E; Valentini, Beatriz; Campero, Carlos M; Moore, Dadín P; Cano, Dora B; Fort, Marcelo; Mota, Rinaldo A; Serrano-Martínez, Marcos E; Cruz-Vázquez, Carlos; Ortega-Mora, Luis M; Álvarez-García, Gema

    2018-01-01

    We carried out an inter-laboratory trial to compare the serological tests commonly used for the detection of specific Neospora caninum antibodies in cattle in Ibero-American countries. A total of eight laboratories participated from the following countries: Argentina (n = 4), Brazil (n = 1), Peru (n = 1), Mexico (n = 1), and Spain (n = 1). A blind panel of well-characterized cattle sera (n = 143) and sera representative of the target population (n = 351) was tested by seven in-house indirect fluorescent antibody tests (IFATs 1-7) and three enzyme-linked immunosorbent assays (ELISAs 1-3; two in-house and one commercial). Diagnostic performance of the serological tests was calculated and compared according to the following criteria: (1) the "Pre-test information," which uses previous epidemiological and serological data; (2) the "Majority of tests," which classifies a serum as positive or negative according to the results obtained by most tests evaluated. Unexpectedly, six tests showed either sensitivity (Se) or specificity (Sp) values lower than 90%. In contrast, the best tests in terms of Se, Sp, and area under the ROC curve (AUC) values were IFAT 1 and optimized ELISA 1 and ELISA 2. We evaluated a high number of IFATs, which are the most widely used tests in Ibero-America. The significant discordances observed among the tests regardless of the criteria employed hinder control programs and urge the use of a common test or with similar performances to either the optimized IFAT 1 and ELISAs 1 and 2.

  9. A Unified Constitutive Model for Subglacial Till, Part II: Laboratory Tests, Disturbed State Modeling, and Validation for Two Subglacial Tills

    NASA Astrophysics Data System (ADS)

    Desai, C. S.; Sane, S. M.; Jenson, J. W.; Contractor, D. N.; Carlson, A. E.; Clark, P. U.

    2006-12-01

    This presentation, which is complementary to Part I (Jenson et al.), describes the application of the Disturbed State Concept (DSC) constitutive model to define the behavior of the deforming sediment (till) underlying glaciers and ice sheets. The DSC includes elastic, plastic, and creep strains, and microstructural changes leading to degradation, failure, and sometimes strengthening or healing. Here, we describe comprehensive laboratory experiments conducted on samples of two regionally significant tills deposited by the Laurentide Ice Sheet: the Tiskilwa Till and Sky Pilot Till. The tests are used to determine the parameters to calibrate the DSC model, which is validated with respect to the laboratory tests by comparing the predictions with test data used to find the parameters, and also comparing them with independent tests not used to find the parameters. Discussion of the results also includes comparison of the DSC model with the classical Mohr-Coulomb model, which has been commonly used for glacial tills. A numerical procedure based on finite element implementation of the DSC is used to simulate an idealized field problem, and its predictions are discussed. Based on these analyses, the unified DSC model is proposed to provide an improved model for subglacial tills compared to other models used commonly, and thus to provide the potential for improved predictions of ice sheet movements.

  10. Optimising the laboratory supply chain: The key to effective laboratory services

    PubMed Central

    Williams, Jason; Smith, Peter; Kuritsky, Joel

    2014-01-01

    Background The Supply Chain Management System (SCMS) is a contract managed under the Partnership for Supply Chain Management (PFSCM) consortium by the United States Agency for International Development (USAID). SCMS procures commodities for programmes supported by the US President’s Emergency Plan for AIDS Relief (PEPFAR). From 2005 to mid-2012, PEPFAR, through SCMS, spent approximately $384 million on non-pharmaceutical commodities. Of this, an estimated $90m was used to purchase flow cytometry technology, largely for flow cytometry platforms and reagents. Objectives The purpose of this paper is to highlight the cost differences between low, medium and high utilisation rates of common CD4 testing instruments that have been procured though PEPFAR funding. Method A scale of costs per test as a function of test volume through the machine was calculated for the two most common CD4 testing machines used in HIV programmes: Becton Dickinson (BD) FACSCount™ and BD FACSCalibur™. Instrument utilisation data collected at the facility level in three selected countries were then used to calculate the onsite cost-per-test experienced in each country. Results Cost analyses indicated that a target of at least 40% utilisation for FACSCount™ and 15% utilisation for FACSCalibur™, respectively, closely approach maximal per-test cost efficiency. The average utilisation rate for CD4 testing instruments varies widely by country, level of laboratory and partner (0% − 68%). Conclusion Our analysis indicates that, because cost-per-test is related inversely to sample throughput, the underutilisation of flow cytometry machines is resulting in an increase in average cost-per-test for many instruments. PMID:29043175

  11. Understanding and interpreting laboratory test results in the clinical management of diabetes mellitus

    USDA-ARS?s Scientific Manuscript database

    The clinical chemistry of diabetes care is unique in Endocrinology, because many of the commonly performed tests, such as assays for glucose, ketones and hemoglobin A1c, are done by the patient at home or by the nurse at the bedside or clinic. Hence, some may assume that these tests are accurate and...

  12. Part 2: Sensitivity comparisons of the insect Centroptilum triangulifer to Ceriodaphnia dubia and Daphnia magna using standard reference toxicants; NaCl, KCl and CuSO4

    EPA Science Inventory

    Criteria for establishing water quality standards that are protective of all native biota are generally based upon laboratory toxicity tests. These test utilize common model organisms that have established test methods. However, only a small portion of species have established ...

  13. Reducing duplicate testing: a comparison of two clinical decision support tools.

    PubMed

    Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert

    2015-05-01

    Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.

  14. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    PubMed

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  15. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China

    PubMed Central

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun

    2015-01-01

    Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033

  16. [Role of medium-sized independent laboratories in control of healthcare-associated infection].

    PubMed

    Anzai, Eiko; Fukui, Toru

    2009-05-01

    In 2006, the Ministry of Health and Welfare revised the regulations regarding the Medical Service Law. The amendments stipulate that all healthcare institutions are required to implement infection control programs. However, small hospitals and clinics have no clinical microbiology laboratories, whereas medium-sized hospitals have few medical technologists and the outsourcing of microbiology tests to independent laboratories is common. The decreasing number of laboratories and recent outsourcing tendency reflect the increasing commercialization, and, with it, the escalating number of commercially operating chains. Each independent laboratory is responsible for supporting activities related to the surveillance, control, and prevention of healthcare-associated infections in the associated small and medium-sized hospitals. The people responsible for infection control in these hospitals usually do not have a background in microbiology. The evaluation of communication between independent laboratory staff and hospital personnel, and rapid turnaround time of microbiology laboratory test reports are important elements ensuring the quality of independent laboratory work. With the pressures of financial constraints in the Japanese medical insurance system, the development of a cost-effective and practical protocol for quality assurance is a real dilemma.

  17. Flow Dynamics In Eccentrically Rotating Flasks Used For Dispersant Effectiveness Testing

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. We used a Hot Wire Anemometer (HWA) to characterize mixing dynamics in the Swirling Flask (SF) and the Baffled Flask (BF), the latter is being considered b...

  18. Settleometer. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Arasmith, E. E.

    The settleometer test is used to indicate the solids-liquid separation (downtime) capability of sludge, most commonly on activated sludge entering the secondary clarifier and aerobic digesters. Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module…

  19. DIRECT DOSING OF PRE-WEANING RODENTS IN TOXICITY TESTING AND RESEARCH: DELIBERATIONS OF AN ILSI RSI EXPERT WORKING GROUP.

    EPA Science Inventory

    Laboratory animal studies that are designed to assess the effects of exposure of a test substance during postnatal development are commonly utilized in basic research and to evaluate potential hazard to children for chemical and pharmaceutical regulation. Direct dosing, defined ...

  20. Vocational Education Safety Instruction Manual.

    ERIC Educational Resources Information Center

    Cropley, Russell, Ed.; Doherty, Susan Sloan, Ed.

    This manual describes four program areas in vocational education safety instruction: (1) introduction to a safety program; (2) resources to ensure laboratory safety; (3) safety program implementation; and (4) safety rules and safety tests. The safety rules and tests included in section four are for the most common tools and machines used in…

  1. [Uniform analyzes of drugs in urine needed for rule of law].

    PubMed

    Hansson, Therese; Helander, Anders; Beck, Olof; Elmgren, Anders; Kugelberg, Fredrik; Kronstrand, Robert

    2015-09-22

    Drugs of abuse testing is used in various areas of society for detection and follow-up of drug use. In routine laboratory drug testing, immunoassays are employed for initial screening of specimens to indicate the presence of drugs. To confirm a positive screening test, a secondary analysis by mass spectrometry is performed. The "cut-off" is the pre-defined concentration threshold of a drug or drug metabolite above which the sample is considered positive. A reading below this level implies a negative test result. Swedish drug testing laboratories currently employ varying cut-offs to distinguish between a positive and a negative test result. Because a positive drug test may have serious legal consequences to the individual, it is of importance that testing is performed and judged equally, regardless of where it is performed. A national harmonization of cut-offs is therefore warranted. Based on data from four major Swedish drug testing laboratories, and considering the recommendations in international guidelines, a proposal for national harmonization of urine cut-offs for the most common set of drugs of abuse is presented.

  2. What do consistently high-performing in vitro fertilization programs in the U.S. do?

    PubMed

    Van Voorhis, Bradley J; Thomas, Mika; Surrey, Eric S; Sparks, Amy

    2010-09-01

    To identify common clinical and laboratory practices among consistently high-performing IVF programs. Questionnaire study of selected IVF programs. Academic and private practice IVF programs. Ten of 12 programs identified as having consistently high singleton delivery rates per cycle. None. Common clinical practices. Common clinical practices identified among these programs included testing all patients for ovarian reserve, endometrial defects, and hydrosalpinges; use of a mixed LH and FSH stimulation protocol with step-down dosing; and use of ultrasound guidance for ET. Common laboratory practices included selective use of intracytoplasmic sperm injection, group culture of embryos in microdrops, and use of blastocyst ET in selected cases. Common laboratory features included good air quality using filtration and heated stages for oocyte and embryo work. Although a number of factors were identified in this best-practices questionnaire, programs often differed in many aspects of care. However, high-performing programs cited experience of physicians, embryologists, and staff members as well as consistency of approach, attention to detail, and good communication as being vital to excellent outcomes. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Laboratory-acquired infections of Salmonella enterica serotype Typhi in South Africa: phenotypic and genotypic analysis of isolates.

    PubMed

    Smith, Anthony Marius; Smouse, Shannon Lucrecia; Tau, Nomsa Pauline; Bamford, Colleen; Moodley, Vineshree Mischka; Jacobs, Charlene; McCarthy, Kerrigan Mary; Lourens, Adré; Keddy, Karen Helena

    2017-09-29

    Workers in clinical microbiology laboratories are exposed to a variety of pathogenic microorganisms. Salmonella species is among the most commonly reported bacterial causes of laboratory-acquired infections. We report on three cases of laboratory-acquired Salmonella enterica serotype Typhi (Salmonella Typhi) infection which occurred over the period 2012 to 2016 in South Africa. Laboratory investigation included phenotypic and genotypic characterization of isolates. Phenotypic analysis included standard microbiological identification techniques, serotyping and antimicrobial susceptibility testing. Genotypic analysis included the molecular subtyping methodologies of pulsed-field gel electrophoresis analysis, multilocus sequence typing and whole-genome sequencing (WGS); with WGS data analysis including phylogenetic analysis based upon comparison of single nucleotide polymorphism profiles of isolates. All cases of laboratory-acquired infection were most likely the result of lapses in good laboratory practice and laboratory safety. The following critical issues were highlighted. There was misdiagnosis and misreporting of Salmonella Typhi as nontyphoidal Salmonella by a diagnostic laboratory, with associated public health implications. We highlight issues concerning the importance of accurate fluoroquinolone susceptibility testing and interpretation of results according to updated guidelines. We describe potential shortcomings of a single disk susceptibility screening test for fluoroquinolone susceptibility and suggest that confirmatory minimum inhibitory concentration testing should always be performed in cases of invasive Salmonella infections. These antimicrobial susceptibility testing issues resulted in inappropriate ciprofloxacin therapy which may have been responsible for failure in clearance of pathogen from patients. Salmonella Typhi capsular polysaccharide vaccine was not protective in one case, possibly secondarily to a faulty vaccine. Molecular subtyping of isolates proved effective to investigate the genetic relatedness of isolates. Molecular subtyping data interpreted together with epidemiological data allowed us to pinpoint the most likely sources for our cases of laboratory-acquired infection.

  4. Test-Enhanced Learning: The Potential for Testing to Promote Greater Learning in Undergraduate Science Courses

    PubMed Central

    Brame, Cynthia J.; Biel, Rachel

    2015-01-01

    Testing within the science classroom is commonly used for both formative and summative assessment purposes to let the student and the instructor gauge progress toward learning goals. Research within cognitive science suggests, however, that testing can also be a learning event. We present summaries of studies that suggest that repeated retrieval can enhance long-term learning in a laboratory setting; various testing formats can promote learning; feedback enhances the benefits of testing; testing can potentiate further study; and benefits of testing are not limited to rote memory. Most of these studies were performed in a laboratory environment, so we also present summaries of experiments suggesting that the benefits of testing can extend to the classroom. Finally, we suggest opportunities that these observations raise for the classroom and for further research. PMID:25999314

  5. Photocatalytic destruction of chlorinated solvents in water with solar energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacheco, J.E.; Prairie, M.R.; Yellowhorse, L.

    1993-08-01

    Sandia National Laboratories and the National Renewable Energy Laboratory are developing a photocatalytic process to destroy organic contaminants in water. Tests with common water pollutants have been conducted at Sandia's Solar Thermal Facility using a near commercial scale, single-axis tracking parabolic trough system with a glass pipe reactor mounted at its focus. Experiments at this scale provide verification of laboratory studies and allow examination of design and operation issues at a real-lifescale. The catalyst, titanium dioxide (TiO[sub 2]), is a harmless material found in paint, cosmetics, and toothpaste. Experiments were conducted to determine the effects of key process parameters onmore » destruction rates of chlorinated organic compounds that are common water pollutants. This paper summarizes the engineering-scale results of these experiments and analyses.« less

  6. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  7. Restructuring of international council for standardization in haematology (ICSH) in Asia.

    PubMed

    Tatsumi, N; Lewis, S M

    2002-08-01

    Standardization and harmonization in Laboratory testing are a key issue in the midst of globalization era, because most of laboratory testing has been currently achieved with various kinds of automated systems. In the developed countries, automated systems with highly-regulated principles are commonly used in the routine laboratory. However, there are so many undeveloped and developing countries in Asia that diversity of testing levels can be observed in the area. Some laboratories use glass chamber method for blood cell counting, while other laboratory use semi-automated or fully automated analyzers for complete blood count. International standardization on Hematology is focused on the developed system but not for the developing system. Established standardized documents therefore whould not be unsuitable for Asian societies. In the context, International Council for Standardization in Hematology (ICSH) changed its rules to adjust our Asian Societies and ICSH started to restructure the body. International ICSH society is divided into 5 region sub-groups. Asian area is able to possess one new sub-society, ICSH-Asia. Its reconstruction work has been just started with Asain colleagues, and we are now extending the new societies to discuss Asian problems on the quality of hematology testing.

  8. Laboratory medicine handoff gaps experienced by primary care practices: A report from the shared networks of collaborative ambulatory practices and partners (SNOCAP).

    PubMed

    West, David R; James, Katherine A; Fernald, Douglas H; Zelie, Claire; Smith, Maxwell L; Raab, Stephen S

    2014-01-01

    The majority of errors in laboratory medicine testing are thought to occur in the pre- and postanalytic testing phases, and a large proportion of these errors are secondary to failed handoffs. Because most laboratory tests originate in ambulatory primary care, understanding the gaps in handoff processes within and between laboratories and practices is imperative for patient safety. Therefore, the purpose of this study was to understand, based on information from primary care practice personnel, the perceived gaps in laboratory processes as a precursor to initiating process improvement activities. A survey was used to assess perceptions of clinicians, staff, and management personnel of gaps in handoffs between primary care practices and laboratories working in 21 Colorado primary care practices. Data were analyzed to determine statistically significant associations between categorical variables. In addition, qualitative analysis of responses to open-ended survey questions was conducted. Primary care practices consistently reported challenges and a desire/need to improve their efforts to systematically track laboratory test status, confirm receipt of laboratory results, and report results to patients. Automated tracking systems existed in roughly 61% of practices, and all but one of those had electronic health record-based tracking systems in place. One fourth of these electronic health record-enabled practices expressed sufficient mistrust in these systems to warrant the concurrent operation of an article-based tracking system as backup. Practices also reported 12 different procedures used to notify patients of test results, varying by test result type. The results highlight the lack of standardization and definition of roles in handoffs in primary care laboratory practices for test ordering, monitoring, and receiving and reporting test results. Results also identify high-priority gaps in processes and the perceptions by practice personnel that practice improvement in these areas is needed. Commonalities in these areas warrant the development and support of tools for use in primary care settings. © Copyright 2014 by the American Board of Family Medicine.

  9. Clinical utility of routine laboratory testing to identify possible secondary causes in older men with osteoporosis: the Osteoporotic Fractures in Men (MrOS) Study

    PubMed Central

    Fink, Howard A.; Litwack-Harrison, Stephanie; Taylor, Brent C.; Bauer, Douglas C.; Orwoll, Eric S.; Lee, Christine G.; Barrett-Connor, Elizabeth; Schousboe, John T.; Kado, Deborah M.; Garimella, Pranav S.; Ensrud, Kristine E.

    2016-01-01

    Purpose To evaluate the utility of recommended laboratory testing to identify secondary causes in older men with osteoporosis, we examined prevalence of laboratory abnormalities in older men with and without osteoporosis. Methods 1572 men aged ≥65 years in the Osteoporotic Fractures in Men study completed bone mineral density (BMD) testing and a battery of laboratory measures, including serum calcium, phosphorus, alkaline phosphatase, parathyroid hormone (PTH), thyroid-stimulating hormone (TSH), 25-OH vitamin D, total testosterone, spot urine calcium/creatinine ratio, spot urine albumin-creatinine ratio, creatinine-derived estimate glomerular filtration rate, 24-hour urine calcium, and 24-hour urine free cortisol. Using cross-sectional analyses, we calculated prevalence ratios (PR) and 95% confidence intervals (CI) for the association of any and specific laboratory abnormalities with osteoporosis, and the number of men with osteoporosis needed to test to identify one additional laboratory abnormality compared to testing men without osteoporosis. Results Approximately 60% of men had ≥1 laboratory abnormality in both men with and without osteoporosis. Among individual tests, only vitamin D insufficiency (PR, 1.13; 95% CI, 1.05–1.22) and high alkaline phosphatase (PR, 3.05; 95% CI, 1.52–6.11) were more likely in men with osteoporosis. Hypercortisolism and hyperthyroidism were uncommon and not significantly more frequent in men with osteoporosis. No osteoporotic men had hypercalciuria. Conclusions Though most of these older men had ≥1 laboratory abnormality, few routinely recommended individual tests were more common in men with osteoporosis than in those without osteoporosis. Possibly excepting vitamin D and alkaline phosphatase, benefit of routine laboratory testing to identify possible secondary causes in older osteoporotic men appears low. Results may not be generalizable to younger men or to older men in whom history and exam findings raise clinical suspicion for a secondary cause of osteoporosis. PMID:26458388

  10. Current Landscape and New Paradigms of Proficiency Testing and External Quality Assessment for Molecular Genetics

    PubMed Central

    Kalman, Lisa V.; Lubin, Ira M.; Barker, Shannon; du Sart, Desiree; Elles, Rob; Grody, Wayne W.; Pazzagli, Mario; Richards, Sue; Schrijver, Iris; Zehnbauer, Barbara

    2015-01-01

    Context Participation in proficiency testing (PT) or external quality assessment (EQA) programs allows the assessment and comparison of test performance among different clinical laboratories and technologies. In addition to the approximately 2300 tests for individual genetic disorders, recent advances in technology have enabled the development of clinical tests which quickly and economically analyze the entire human genome. New PT/EQA approaches are needed to ensure the continued quality of these complex tests. Objective To review the availability and scope of PT/EQA for molecular genetic testing for inherited conditions in Europe, Australasia and the United States; to evaluate the successes and demonstrated value of available PT/EQA programs; and to examine the challenges to the provision of comprehensive PT/EQA posed by new laboratory practices and methodologies. Data Sources The available literature on this topic was reviewed and supplemented with personal experiences of several PT/EQA providers. Conclusions PT/EQA schemes are available for common genetic disorders tested in many clinical laboratories, but are not available for most genetic tests offered by only one or a few laboratories. Provision of broad, method-based PT schemes, such as DNA sequencing, would allow assessment of a large number of tests for which formal PT is not currently available. Participation in PT/EQA improves the quality of testing by identifying inaccuracies that laboratories can trace to errors in the testing process. Areas of research and development to ensure that PT/EQA programs can meet the needs of new and evolving genetic tests and technologies are identified and discussed. PMID:23808472

  11. Experimental assessment of aggregate surfacing materials.

    DOT National Transportation Integrated Search

    2007-06-30

    "An extensive suite of geotechnical laboratory tests were conducted to quantify differences in : engineering properties of three crushed aggregates commonly used on Montana highway projects. The : material types are identified in the Montana Suppleme...

  12. Photocatalytic destruction of chlorinated solvents with solar energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacheco, J.; Prairie, M.; Yellowhorse, L.

    1990-01-01

    Sandia National Laboratories and the Solar Energy Research Institute are developing a photocatalytic process to destroy organic contaminants in water. Tests with common water pollutants are being conducted at Sandia's Solar Thermal Test Facility using a near commercial-scale single-axis tracking parabolic trough system with glass pipe mounted at its focus. Experiments at this scale provide verification of laboratory studies and allow examination of design and operation issues at a real-life scale. The catalyst, titanium dioxide (TiO{sub 2}), is a harmless material found in paint, cosmetics and toothpaste. Experiments were conducted to determine the effect of key process parameters on destructionmore » rates of two chlorinated organic compounds which are common water pollutants: trichloroethylene and trichloroethane. In this paper, we summarize the engineering-scale results of these experiments and analyses. 21 refs., 8 figs.« less

  13. TREAT Asia Quality Assessment Scheme (TAQAS) to standardize the outcome of HIV genotypic resistance testing in a group of Asian laboratories

    PubMed Central

    Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew

    2010-01-01

    The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972

  14. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    PubMed

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or <40 U/dL, 99.5% of results (859/863) were correctly classified by laboratories as normal/abnormal. Classification of specimens with 40-73 U/dL FVII was heterogeneous. Interlaboratory precision was better for normal specimens (coefficient of variation (CV) 10.7%) than for FVII<20 U/dL (CV 33.1%), with a mean CV of 17.2% per specimen. Intralaboratory precision for repeated specimens demonstrated no significant difference between the paired survey results (mean absolute difference 2.5-5.0 U/dL). For specimens with FVII >50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  16. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    PubMed

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all p<0.05). Although alkaline phosphatase, total bilirubin and hemoglobin reached statistical significance (p=0.009, 0.027 and 0.012, respectively), all had very low average bias which ranged from 0.01% to 2%. Potassium, total hemoglobin and percent deoxyhemoglobin were statistically significant for the neonatal capillary tube study (p=0.011, 0.033 and 0.041, respectively) but no biases greater than ±4% were identified for these parameters. All observed differences of these 48 laboratory tests were not clinically significant. The modern PTS investigated in this study is acceptable for reliable sample delivery for routine chemistry, hematology, coagulation and blood gas (in syringe and capillary tube) laboratory tests.

  17. Updating the immunology curriculum in clinical laboratory science.

    PubMed

    Stevens, C D

    2000-01-01

    To determine essential content areas of immunology/serology courses at the clinical laboratory technician (CLT) and clinical laboratory scientist (CLS) levels. A questionnaire was designed which listed all major topics in immunology and serology. Participants were asked to place a check beside each topic covered. For an additional list of serological and immunological laboratory testing, participants were asked to indicate if each test was performed in either the didactic or clinical setting, or not performed at all. A national survey of 593 NAACLS approved CLT and CLS programs was conducted by mail under the auspices of ASCLS. Responses were obtained from 158 programs. Respondents from all across the United States included 60 CLT programs, 48 hospital-based CLS programs, 45 university-based CLS programs, and 5 university-based combined CLT and CLS programs. The survey was designed to enumerate major topics included in immunology and serology courses by a majority of participants at two distinct educational levels, CLT and CLS. Laboratory testing routinely performed in student laboratories as well as in the clinical setting was also determined for these two levels of practitioners. Certain key topics were common to most immunology and serology courses. There were some notable differences in the depth of courses at the CLT and CLS levels. Laboratory testing associated with these courses also differed at the two levels. Testing requiring more detailed interpretation, such as antinuclear antibody patterns (ANAs), was mainly performed by CLS students only. There are certain key topics as well as specific laboratory tests that should be included in immunology/serology courses at each of the two different educational levels to best prepare students for the workplace. Educators can use this information as a guide to plan a curriculum for such courses.

  18. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains

    PubMed Central

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-01-01

    Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033

  19. A microcomputer-based testing station for dynamic and static testing of protective relay systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, W.J.; Li, R.J.; Gu, J.C.

    1995-12-31

    Dynamic and static relay performance testing before installation in the field is a subject of great interest to utility relay engineers. The common practice in utility testing of new relays is to put the new unit to be tested in parallel with an existing functioning relay in the system, wait until an actual transient occurs and then observe and analyze the performance of new relay. It is impossible to have a thorough test of the protective relay system through this procedure. An equipment, Microcomputer-Based Testing Station (or PC-Based Testing Station), that can perform both static and dynamic testing of themore » relay is described in this paper. The Power System Simulation Laboratory at the University of Texas at Arlington is a scaled-down, three-phase, physical power system which correlates well with the important components for a real power system and is an ideal facility for the dynamic and static testing of protective relay systems. A brief introduction to the configuration of this laboratory is presented. Test results of several protective functions by using this laboratory illustrate the usefulness of this test set-up.« less

  20. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    PubMed

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  1. Current methods of laboratory diagnosis of Chlamydia trachomatis infections.

    PubMed Central

    Black, C M

    1997-01-01

    Infections caused by Chlamydia trachomatis are probably the most common sexually transmitted diseases in the United States. Commonly unrecognized and often inadequately treated, chlamydial infections can ascend the reproductive tract and cause pelvic inflammatory disease, which often results in the devastating consequences of infertility, ectopic pregnancy, or chronic pelvic pain. C. trachomatis infections are also known to increase the risk for human immunodeficiency virus infection. The obligate intracellular life cycle of C. trachomatis has traditionally required laboratory diagnostic tests that are technically demanding, labor-intensive, expensive, and difficult to access. In spite of these historical challenges, however, laboratory diagnosis of C. trachomatis has been a rapidly advancing area in which there is presently a wide array of commercial diagnostic technologies, costs, manufacturers. This review describes and compares the diagnostic methods for C. trachomatis infection that are currently approved for use in the United States, including the newest DNA amplification technologies which are yet to be licensed for commercial use. Issues to consider in selecting a test for purposes of screening versus diagnosis based on prevalence, performance, legal, social, and cost issues are also discussed. PMID:8993862

  2. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    PubMed

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  3. Identification of an Astrovirus Commonly Infecting Laboratory Mice in the US and Japan

    PubMed Central

    Ng, Terry Fei Fan; Kondov, Nikola O.; Hayashimoto, Nobuhito; Uchida, Ritsuki; Cha, Yunhee; Beyer, Ashley I.; Wong, Walt; Pesavento, Patricia A.; Suemizu, Hiroshi; Muench, Marcus O.; Delwart, Eric

    2013-01-01

    Mice (Mus musculus) are the most commonly used laboratory animals. Viral metagenomics on tissues of immunodeficient mice revealed sequences of a novel mammalian astrovirus. Using PCR, we screened mice from 4 breeders, 4 pharmaceutical companies, 14 research institutes and 30 universities in the US and Japan. Mice from one US breeder tested positive while none from Japanese breeders were positive for MuAstV. Mice in over half of the universities (19/30), institutes (7/14) and pharmaceutical animal facilities (2/4) investigated revealed the presence of MuAstV. Nine mice strains tested positive including both immunodeficient strains (NSG, NOD-SCID, NSG-3GS, C57BL6-Timp-3 −/−, and uPA-NOG) and immunocompetent strains (B6J, ICR, Bash2, BALB/c). Our data indicates that MuAstV has a wide geographical, institutional and host strain distribution. Comparison of the MuAstV RdRp sequences showed numerous mutations indicating ongoing viral divergence in different facilities. This study demonstrates the need for metagenomic screening of laboratory animals to identify adventitious infections that may affect experimental outcomes. PMID:23825590

  4. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  5. ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG SOUTH PERIMETER WALL (COMMON TO ELECTRICAL BUILDING, TRA-648). CAMERA FACES WEST. INL NEGATIVE NO. HD46-16-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  6. Effect of Population Heterogenization on the Reproducibility of Mouse Behavior: A Multi-Laboratory Study

    PubMed Central

    Richter, S. Helene; Garner, Joseph P.; Zipser, Benjamin; Lewejohann, Lars; Sachser, Norbert; Touma, Chadi; Schindler, Britta; Chourbaji, Sabine; Brandwein, Christiane; Gass, Peter; van Stipdonk, Niek; van der Harst, Johanneke; Spruijt, Berry; Võikar, Vootele; Wolfer, David P.; Würbel, Hanno

    2011-01-01

    In animal experiments, animals, husbandry and test procedures are traditionally standardized to maximize test sensitivity and minimize animal use, assuming that this will also guarantee reproducibility. However, by reducing within-experiment variation, standardization may limit inference to the specific experimental conditions. Indeed, we have recently shown in mice that standardization may generate spurious results in behavioral tests, accounting for poor reproducibility, and that this can be avoided by population heterogenization through systematic variation of experimental conditions. Here, we examined whether a simple form of heterogenization effectively improves reproducibility of test results in a multi-laboratory situation. Each of six laboratories independently ordered 64 female mice of two inbred strains (C57BL/6NCrl, DBA/2NCrl) and examined them for strain differences in five commonly used behavioral tests under two different experimental designs. In the standardized design, experimental conditions were standardized as much as possible in each laboratory, while they were systematically varied with respect to the animals' test age and cage enrichment in the heterogenized design. Although heterogenization tended to improve reproducibility by increasing within-experiment variation relative to between-experiment variation, the effect was too weak to account for the large variation between laboratories. However, our findings confirm the potential of systematic heterogenization for improving reproducibility of animal experiments and highlight the need for effective and practicable heterogenization strategies. PMID:21305027

  7. Contrasting effects of chloride on growth, reproduction, and toxicant sensitivity in two genetically distinct strains of Hyalella azteca.

    PubMed

    Soucek, David J; Mount, David R; Dickinson, Amy; Hockett, J Russell; McEwen, Abigail R

    2015-10-01

    The strain of Hyalella azteca (Saussure: Amphipoda) commonly used for aquatic toxicity testing in the United States has been shown to perform poorly in some standardized reconstituted waters frequently used for other test species. In 10-d and 42-d experiments, the growth and reproduction of the US laboratory strain of H. azteca was shown to vary strongly with chloride concentration in the test water, with declining performance observed below 15 mg/L to 20 mg/L. In contrast to the chloride-dependent performance of the US laboratory strain of H. azteca, growth of a genetically distinct strain of H. azteca obtained from an Environment Canada laboratory in Burlington, Ontario, Canada, was not influenced by chloride concentration. In acute toxicity tests with the US laboratory strain of H. azteca, the acute toxicity of sodium nitrate increased with decreasing chloride in a pattern similar not only to that observed for control growth, but also to previous acute toxicity testing with sodium sulfate. Subsequent testing with the Burlington strain showed no significant relationship between chloride concentration and the acute toxicity of sodium nitrate or sodium sulfate. These findings suggest that the chloride-dependent toxicity shown for the US laboratory strain may be an unusual feature of that strain and perhaps not broadly representative of aquatic organisms as a whole. © 2015 SETAC.

  8. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  9. EGFR T790M mutation testing within the osimertinib AURA Phase I study.

    PubMed

    Dearden, Simon; Brown, Helen; Jenkins, Suzanne; Thress, Kenneth S; Cantarini, Mireille; Cole, Rebecca; Ranson, Malcolm; Jänne, Pasi A

    2017-07-01

    Reliable epidermal growth factor receptor (EGFR) mutation testing techniques are required to identify eligible patients with EGFR mutation/T790M positive advanced non-small cell lung cancer (NSCLC), for treatment with osimertinib (AZD9291), an oral, potent, irreversible EGFR tyrosine kinase inhibitor (TKI) selective for EGFR-TKI-sensitizing and T790M resistance mutations over wild-type EGFR. There is no current consensus regarding the best method to detect EGFR T790M mutations. The aim of this study was to describe the concordance between local testing, which used a variety of methods, and central testing, using the cobas ® EGFR Mutation Test, for EGFR-sensitizing mutations and the T790M resistance mutation. Tumor samples were obtained from all patients screened for inclusion onto the osimertinib Phase I expansion component of the AURA Phase I/II study (NCT01802632). Samples underwent central laboratory testing for EGFR-sensitizing mutations and T790M resistance mutation using the cobas ® EGFR Mutation Test. Results were compared with local laboratory test results, based on other testing methodologies including Sanger sequencing, therascreen ® , PNAClamp™, and Sequenom MassARRAY ® . Central laboratory testing was successful in 99% of samples passing histopathology review and testing success rates were comparable across the three central laboratories. Concordance between central and local testing for common sensitizing mutations was high (>98%) and concordance for the T790M mutation was also high (>90%). Tumor heterogeneity, along with other technical factors may have influenced this result. Within the osimertinib AURA Phase I study, EGFR mutation testing across three centralized laboratories using the cobas ® EGFR Mutation Test was feasible and successful, with strong concordance between local and central laboratory results, including for T790M. The cobas ® EGFR Mutation Test has subsequently been approved as the companion diagnostic test for osimertinib in the USA and Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. New Rock Abrasivity Test Method for Tool Life Assessments on Hard Rock Tunnel Boring: The Rolling Indentation Abrasion Test (RIAT)

    NASA Astrophysics Data System (ADS)

    Macias, F. J.; Dahl, F.; Bruland, A.

    2016-05-01

    The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.

  11. Proposed quality control guidelines for antimicrobial susceptibility tests using tilmicosin.

    PubMed Central

    Shryock, T R; White, D W; Werner, C S; Staples, J M

    1995-01-01

    Quality control guidelines for tilmicosin, a novel veterinary-use-only macrolide, were developed in a multi-laboratory study according to established National Committee for Clinical Laboratory Standards (NCCLS) procedures (M23-T2). Tilmicosin was incorporated into Sensititre plates for broth microdilution endpoint testing and into two lots of 15-micrograms disks for Kirby-Bauer agar disk diffusion testing. One common lot and five unique lots of Mueller-Hinton media were used. (Broth was cation adjusted, and agar was supplemented with 5% defibrinated sheep blood.) Bacteria used for reference strains included Pasteurella haemolytica 128K, Pasteurella multocida ATCC 43137, and Staphylococcus aureus ATCC 29213 (microdilution) and ATCC 25923 (disk). Replicate tests were conducted. Disk diffusion and broth microdilution quality control ranges are proposed. PMID:7714188

  12. Comparison of species-level identification and antifungal susceptibility results from diagnostic and reference laboratories for bloodstream Candida surveillance isolates, South Africa, 2009-2010.

    PubMed

    Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P

    2016-11-01

    From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under-reported fluconazole resistance for C. parapsilosis and over-reported fluconazole resistance for C. albicans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. 3D-MICE: integration of cross-sectional and longitudinal imputation for multi-analyte longitudinal clinical data.

    PubMed

    Luo, Yuan; Szolovits, Peter; Dighe, Anand S; Baron, Jason M

    2018-06-01

    A key challenge in clinical data mining is that most clinical datasets contain missing data. Since many commonly used machine learning algorithms require complete datasets (no missing data), clinical analytic approaches often entail an imputation procedure to "fill in" missing data. However, although most clinical datasets contain a temporal component, most commonly used imputation methods do not adequately accommodate longitudinal time-based data. We sought to develop a new imputation algorithm, 3-dimensional multiple imputation with chained equations (3D-MICE), that can perform accurate imputation of missing clinical time series data. We extracted clinical laboratory test results for 13 commonly measured analytes (clinical laboratory tests). We imputed missing test results for the 13 analytes using 3 imputation methods: multiple imputation with chained equations (MICE), Gaussian process (GP), and 3D-MICE. 3D-MICE utilizes both MICE and GP imputation to integrate cross-sectional and longitudinal information. To evaluate imputation method performance, we randomly masked selected test results and imputed these masked results alongside results missing from our original data. We compared predicted results to measured results for masked data points. 3D-MICE performed significantly better than MICE and GP-based imputation in a composite of all 13 analytes, predicting missing results with a normalized root-mean-square error of 0.342, compared to 0.373 for MICE alone and 0.358 for GP alone. 3D-MICE offers a novel and practical approach to imputing clinical laboratory time series data. 3D-MICE may provide an additional tool for use as a foundation in clinical predictive analytics and intelligent clinical decision support.

  14. Observations of the Kaiser effect under multiaxial stress states: Implications for its use in determining in situ stress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holcomb, D.J.

    1993-10-08

    Experimental tests of the Kaiser effect, the stress-history dependence of acoustic emission production, show that interactions between principal stresses cannot be ignored as is commonly done when trying to use the Kaiser effect to determine in situ stress. Experimental results obtained under multiaxial stress states are explained in terms of a qualitative model. The results show that the commonly-used technique of loading uniaxially along various directions to determine stress history must be reevaluated as it cannot be justified in terms of the laboratory experiments. One possible resolution of the conflict between laboratory and field results is that the Kaiser effectmore » phenomenon observed in cores retrieved from the earth is not the same phenomenon as is observed in rock loaded under laboratory conditions.« less

  15. Comparison of multianalyte proficiency test results by sum of ranking differences, principal component analysis, and hierarchical cluster analysis.

    PubMed

    Škrbić, Biljana; Héberger, Károly; Durišić-Mladenović, Nataša

    2013-10-01

    Sum of ranking differences (SRD) was applied for comparing multianalyte results obtained by several analytical methods used in one or in different laboratories, i.e., for ranking the overall performances of the methods (or laboratories) in simultaneous determination of the same set of analytes. The data sets for testing of the SRD applicability contained the results reported during one of the proficiency tests (PTs) organized by EU Reference Laboratory for Polycyclic Aromatic Hydrocarbons (EU-RL-PAH). In this way, the SRD was also tested as a discriminant method alternative to existing average performance scores used to compare mutlianalyte PT results. SRD should be used along with the z scores--the most commonly used PT performance statistics. SRD was further developed to handle the same rankings (ties) among laboratories. Two benchmark concentration series were selected as reference: (a) the assigned PAH concentrations (determined precisely beforehand by the EU-RL-PAH) and (b) the averages of all individual PAH concentrations determined by each laboratory. Ranking relative to the assigned values and also to the average (or median) values pointed to the laboratories with the most extreme results, as well as revealed groups of laboratories with similar overall performances. SRD reveals differences between methods or laboratories even if classical test(s) cannot. The ranking was validated using comparison of ranks by random numbers (a randomization test) and using seven folds cross-validation, which highlighted the similarities among the (methods used in) laboratories. Principal component analysis and hierarchical cluster analysis justified the findings based on SRD ranking/grouping. If the PAH-concentrations are row-scaled, (i.e., z scores are analyzed as input for ranking) SRD can still be used for checking the normality of errors. Moreover, cross-validation of SRD on z scores groups the laboratories similarly. The SRD technique is general in nature, i.e., it can be applied to any experimental problem in which multianalyte results obtained either by several analytical procedures, analysts, instruments, or laboratories need to be compared.

  16. A Study on the Effects of Sympathetic Skin Response Parameters in Diagnosis of Fibromyalgia Using Artificial Neural Networks.

    PubMed

    Ozkan, Ozhan; Yildiz, Murat; Arslan, Evren; Yildiz, Sedat; Bilgin, Suleyman; Akkus, Selami; Koyuncuoglu, Hasan R; Koklukaya, Etem

    2016-03-01

    Fibromyalgia syndrome (FMS), usually observed commonly in females over age 30, is a rheumatic disease accompanied by extensive chronic pain. In the diagnosis of the disease non-objective psychological tests and physiological tests and laboratory test results are evaluated and clinical experiences stand out. However, these tests are insufficient in differentiating FMS with similar diseases that demonstrate symptoms of extensive pain. Thus, objective tests that would help the diagnosis are needed. This study analyzes the effect of sympathetic skin response (SSR) parameters on the auxiliary tests used in FMS diagnosis, the laboratory tests and physiological tests. The study was conducted in Suleyman Demirel University, Faculty of Medicine, Physical Medicine and Rehabilitation Clinic in Turkey with 60 patients diagnosed with FMS for the first time and a control group of 30 healthy individuals. In the study all participants underwent laboratory tests (blood tests), certain physiological tests (pulsation, skin temperature, respiration) and SSR measurements. The test data and SSR parameters obtained were classified using artificial neural network (ANN). Finally, in the ANN framework, where only laboratory and physiological test results were used as input, a simulation result of 96.51 % was obtained, which demonstrated diagnostic accuracy. This data, with the addition of SSR parameter values obtained increased to 97.67 %. This result including SSR parameters - meaning a higher diagnostic accuracy - demonstrated that SSR could be a new auxillary diagnostic method that could be used in the diagnosis of FMS.

  17. Coccidioidomycosis as a Common Cause of Community-acquired Pneumonia

    PubMed Central

    Valdivia, Lisa; Nix, David; Wright, Mark; Lindberg, Elizabeth; Fagan, Timothy; Lieberman, Donald; Stoffer, T'Prien; Ampel, Neil M.

    2006-01-01

    The early manifestations of coccidioidomycosis (valley fever) are similar to those of other causes of community-acquired pneumonia (CAP). Without specific etiologic testing, the true frequency of valley fever may be underestimated by public health statistics. Therefore, we conducted a prospective observational study of adults with recent onset of a lower respiratory tract syndrome. Valley fever was serologically confirmed in 16 (29%) of 55 persons (95% confidence interval 16%–44%). Antimicrobial medications were used in 81% of persons with valley fever. Symptomatic differences at the time of enrollment had insufficient predictive value for valley fever to guide clinicians without specific laboratory tests. Thus, valley fever is a common cause of CAP after exposure in a disease-endemic region. If CAP develops in persons who travel or reside in Coccidioides-endemic regions, diagnostic evaluation should routinely include laboratory evaluation for this organism. PMID:16707052

  18. [Standardization of terminology in laboratory medicine I].

    PubMed

    Yoon, Soo Young; Yoon, Jong Hyun; Min, Won Ki; Lim, Hwan Sub; Song, Junghan; Chae, Seok Lae; Lee, Chang Kyu; Kwon, Jung Ah; Lee, Kap No

    2007-04-01

    Standardization of medical terminology is essential for data transmission between health-care institutions or clinical laboratories and for maximizing the benefits of information technology. Purpose of our study was to standardize the medical terms used in the clinical laboratory, such as test names, units, terms used in result descriptions, etc. During the first year of the study, we developed a standard database of concept names for laboratory terms, which covered the terms used in government health care centers, their branch offices, and primary health care units. Laboratory terms were collected from the electronic data interchange (EDI) codes from National Health Insurance Corporation (NHIC), Logical Observation Identifier Names and Codes (LOINC) database, community health centers and their branch offices, and clinical laboratories of representative university medical centers. For standard expression, we referred to the English-Korean/ Korean-English medical dictionary of Korean Medical Association and the rules for foreign language translation. Programs for mapping between LOINC DB and EDI code and for translating English to Korean were developed. A Korean standard laboratory terminology database containing six axial concept names such as components, property, time aspect, system (specimen), scale type, and method type was established for 7,508 test observations. Short names and a mapping table for EDI codes and Unified Medical Language System (UMLS) were added. Synonym tables for concept names, words used in the database, and six axial terms were prepared to make it easier to find the standard terminology with common terms used in the field of laboratory medicine. Here we report for the first time a Korean standard laboratory terminology database for test names, result description terms, result units covering most laboratory tests in primary healthcare centers.

  19. Building Diversified Multiple Trees for classification in high dimensional noisy biomedical data.

    PubMed

    Li, Jiuyong; Liu, Lin; Liu, Jixue; Green, Ryan

    2017-12-01

    It is common that a trained classification model is applied to the operating data that is deviated from the training data because of noise. This paper will test an ensemble method, Diversified Multiple Tree (DMT), on its capability for classifying instances in a new laboratory using the classifier built on the instances of another laboratory. DMT is tested on three real world biomedical data sets from different laboratories in comparison with four benchmark ensemble methods, AdaBoost, Bagging, Random Forests, and Random Trees. Experiments have also been conducted on studying the limitation of DMT and its possible variations. Experimental results show that DMT is significantly more accurate than other benchmark ensemble classifiers on classifying new instances of a different laboratory from the laboratory where instances are used to build the classifier. This paper demonstrates that an ensemble classifier, DMT, is more robust in classifying noisy data than other widely used ensemble methods. DMT works on the data set that supports multiple simple trees.

  20. The Impact of the Affordable Care Act on Funding for Newborn Screening Services.

    PubMed

    Costich, Julia F; Durst, Andrea L

    2016-01-01

    The Affordable Care Act requires most health plans to cover the federal Recommended Uniform Screening Panel of newborn screening (NBS) tests with no cost sharing. However, state NBS programs vary widely in both the number of mandated tests and their funding mechanisms, including a combination of state laboratory fees, third-party billing, and other federal and state funding. We assessed the potential impact of the Affordable Care Act coverage mandate on states' NBS funding. We performed an extensive review of the refereed literature, federal and state agency reports, relevant organizations' websites, and applicable state laws and regulations; interviewed 28 state and federal officials from August to December 2014; and then assessed the interview findings manually. Although a majority of states had well-established systems for including laboratory-based NBS tests in bundled charges for newborn care, billing practices for critical congenital heart disease and newborn hearing tests were less uniform. Most commonly, birthing facilities either prepaid the costs of laboratory-based tests when acquiring the filter paper kits, or the facilities paid for the tests when the kits were submitted. Some states had separate arrangements for billing Medicaid, and smaller facilities sometimes contracted with hearing test vendors that billed families separately. Although the Affordable Care Act coverage mandate may offset some state NBS funding for the screenings themselves, federal support is still required to assure access to the full range of NBS program services. Limiting reimbursement to the costs of screening tests alone would undermine the common practice of using screening charges to fund follow-up services counseling, and medical food or formula, particularly for low-income families.

  1. Evaluation of Mycology Laboratory Proficiency Testing

    PubMed Central

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  2. [Reference values in the usual laboratory data for sub-Saharan immigrants. Importance in the management of infectious diseases].

    PubMed

    Sanz-Peláez, O; Angel-Moreno, A; Tapia-Martín, M; Conde-Martel, A; Carranza-Rodríguez, C; Carballo-Rastrilla, S; Soria-López, A; Pérez-Arellano, J L

    2008-09-01

    The progressive increase in the number of immigrants to Spain in recent years has made it necessary for health-care professionals to be aware about the specific characteristics of this population. An attempt is made in this study to define the normal range of common laboratory values in healthy sub-Saharan adults. Common laboratory values were studied (blood cell counts, clotting tests and blood biochemistry values) and were measured in 150 sub-Saharan immigrants previously defined as healthy according to a complete health evaluation that included a clinical history, physical examination, serologic tests and study of stool parasites. These results were compared to those from a control group consisting of 81 age-and-sex matched healthy blood donors taken from the Spanish native population. Statistically significant differences were obtained in the following values. Mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocytes, and serum levels of creatinine, uric acid, total protein content, creatin-kinase (CK), aspartate aminotransferase (AST), gamma-glutamyl-transpeptidase (GGT), Immunoglobulin G (IgG) and M (IgM). If evaluated according to the normal values in native people, a considerable percentage of healthy sub-Saharan immigrants would present values (with potential clinical relevance) in the following parameters. MCV, RDW, total leukocyte counts and serum levels of CK, IgG and IgM. A proper interpretation of the common laboratory values in sub-Saharan immigrants, and probably in other foreign collectives, requires a previously-established range of normality in these parameters for those populations in order to avoid diagnostic mistakes and inadequate work-up and management.

  3. Designation, diligence and drift: understanding laboratory expenditure increases in British Columbia, 1996/97 to 2005/06.

    PubMed

    Sivananthan, Saskia N; Peterson, Sandra; Lavergne, Ruth; Barer, Morris L; McGrail, Kimberlyn M

    2012-12-21

    Laboratory testing is one of the fastest growing areas of health services spending in Canada. We examine the extent to which increases in laboratory expenditures might be explained by testing that is consistent with guidelines for the management of chronic conditions, by analyzing fee-for-service physician payment data in British Columbia from 1996/97 and 2005/06. We used direct standardization to quantify the effect on laboratory expenditures from changes in: fee levels; population growth; population aging; treatment prevalence; expenditure on recommended tests for those conditions; and expenditure on other tests. The chronic conditions selected were those with guidelines containing laboratory recommendations developed by the BC Guidelines and Protocol Advisory Committee: diabetes, hypertension, congestive heart failure, renal failure, liver disease, rheumatoid arthritis, osteoarthritis and dementia. Laboratory service expenditures increased by $98 million in 2005/06 compared to 1996/97, or 3.6% per year after controlling for population growth and aging. Testing consistent with guideline-recommended care for chronic conditions explained one-third (1.2% per year) of this growth. Changes in treatment prevalence were just as important, contributing 1.5% per year. Hypertension was the most common condition, but renal failure and dementia showed the largest changes in prevalence over time. Changes in other laboratory expenditure including for those without chronic conditions accounted for the remaining 0.9% growth per year. Increases in treatment prevalence were the largest driver of laboratory cost increases between 1996/97 and 2005/06. There are several possible contributors to increasing treatment prevalence, all of which can be expected to continue to put pressure on health care expenditures.

  4. INTERNATIONAL STANDARDS ON FOOD AND ENVIRONMENTAL RADIOACTIVITY MEASUREMENT FOR RADIOLOGICAL PROTECTION: STATUS AND PERSPECTIVES.

    PubMed

    Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T

    2017-04-01

    Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Selective control of common crap: ineffectiveness of 2-(digeranylamino)-ethanol (GD-174) in pond trials

    USGS Publications Warehouse

    Gilderhus, P.A.; Burress, R.M.

    1983-01-01

    The candidate piscicide, 2-(digeranylamino)-ethanol, (commonly known as GD-174) was subjected to efficacy trials in ponds under a wide variety of conditions. Results of the trials were disappointing considering that laboratory tests had shown the compound to be selectively toxic to common carp (Cyprinus carpio). Results of pretreatment, on-site toxicity tests were misleading and indicated concentrations that failed to kill all of the carp in 19 of 23 ponds. In a few instances, the chemical killed the carp with little or no effect on nontarget fishes. No fish were killed in some trials and large numbers of nontarget fishes were killed in others. Twenty of 25 pond trials were judged to be unsuccessful. Success or failure of pond treatments could not be correlated with any particular combination of physical, chemical, and biological factors. Because the activity of GD-174 against mixed populations of fish cannot be predicted, further development of this compound as a selective toxicant for carp has been discontinued at the National Fishery Research Laboratory.

  6. HPV Testing of Head and Neck Cancer in Clinical Practice.

    PubMed

    Robinson, Max

    The pathology laboratory has a central role in providing human papillomavirus (HPV) tests for patients with head and neck cancer. There is an extensive literature around HPV testing and a large number of proprietary HPV tests, which makes the field difficult to navigate. This review provides a concise contemporary overview of the evidence around HPV testing in head and neck cancer and signposts key publications, guideline documents and the most commonly used methods in clinical practice.

  7. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    PubMed

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Wild Mammalian Biomonitors for Assessing Impacts of Environmental Contamination on Population and Community Ecology

    DTIC Science & Technology

    1993-06-01

    will be compared to common laboratory bioassay tests (fathea minnow survival, rice seed germination test, etc.), relative to their ability to pre- ’dict...rice seed germination , and Ceriodaphnia assays. At the ecosystem level, in situ small mammal total biomass, sex ratios, reproduction, recruit- ment...bioassay tests (fathead minnow survival, rice seed germination test, etc.), relative to their ability to predict ecotoxicity risks (as indexed by

  9. Changing needs, opportunities and constraints for the 21st century microbiology laboratory.

    PubMed

    Van Eldere, J

    2005-04-01

    Clinical microbiologists and microbiology laboratories are experiencing changes due to evolving views on 'healthcare delivery' as an economic activity, due to changes in the medical environment and the demographics of the workforce, and technical evolution. Cost-effectiveness of laboratory procedures has been achieved through consolidation and integration of laboratories. Consolidation offers economy of scale and reduction in numbers of on-site staff, but also leads to separation of microbiologists from their clinical colleagues. Integration puts different laboratory disciplines under a single management, and leads to reorganisation of laboratories along common work-lines. Cost-savings combined with on-site availability of laboratories are achieved at the expense of a reduction in the influence of microbiologists in the daily running of the laboratory. Medically, there is growing emphasis on evidence-based diagnostics. Because of time-delays inherent in culturing, microbiology through rapid testing is mandatory. There is an increasing shortage in Europe and the USA of trained microbiology laboratory technicians and microbiologists. This reinforces the trend towards more automation and integration. Technological advances, particularly in molecular diagnostics, offer the possibility of rapid reporting and improvement of the impact of clinical microbiology on patient management. Molecular tests, however, fit perfectly the concept of an integrated laboratory and may further loosen the link between microbiologist and microbiology tests. The challenge for clinical microbiology will be to use new techniques to improve its cost-effectiveness and impact on infectious disease management. The future organisation of microbiology laboratories must support this but is itself of secondary importance. The training of future microbiologist must prepare them for this changing environment.

  10. Multicenter Evaluation of a Commercial Cytomegalovirus Quantitative Standard: Effects of Commutability on Interlaboratory Concordance

    PubMed Central

    Shahbazian, M. D.; Valsamakis, A.; Boonyaratanakornkit, J.; Cook, L.; Pang, X. L.; Preiksaitis, J. K.; Schönbrunner, E. R.; Caliendo, A. M.

    2013-01-01

    Commutability of quantitative reference materials has proven important for reliable and accurate results in clinical chemistry. As international reference standards and commercially produced calibration material have become available to address the variability of viral load assays, the degree to which such materials are commutable and the effect of commutability on assay concordance have been questioned. To investigate this, 60 archived clinical plasma samples, which previously tested positive for cytomegalovirus (CMV), were retested by five different laboratories, each using a different quantitative CMV PCR assay. Results from each laboratory were calibrated both with lab-specific quantitative CMV standards (“lab standards”) and with common, commercially available standards (“CMV panel”). Pairwise analyses among laboratories were performed using mean results from each clinical sample, calibrated first with lab standards and then with the CMV panel. Commutability of the CMV panel was determined based on difference plots for each laboratory pair showing plotted values of standards that were within the 95% prediction intervals for the clinical specimens. Commutability was demonstrated for 6 of 10 laboratory pairs using the CMV panel. In half of these pairs, use of the CMV panel improved quantitative agreement compared to use of lab standards. Two of four laboratory pairs for which the CMV panel was noncommutable showed reduced quantitative agreement when that panel was used as a common calibrator. Commutability of calibration material varies across different quantitative PCR methods. Use of a common, commutable quantitative standard can improve agreement across different assays; use of a noncommutable calibrator can reduce agreement among laboratories. PMID:24025907

  11. TROPHIC EFFECT OF LUTEINIZING HORMONE ON THE RAT LEYDIG CELL

    EPA Science Inventory

    Little is known about the factors controlling Leydig cell growth and differentiation. owever, unique correlations exist between specific testicular compartments and the testosterone-secreting capacity of the testes. elected experimental findings from three common laboratory anima...

  12. Towards a standardization of biomethane potential tests.

    PubMed

    Holliger, Christof; Alves, Madalena; Andrade, Diana; Angelidaki, Irini; Astals, Sergi; Baier, Urs; Bougrier, Claire; Buffière, Pierre; Carballa, Marta; de Wilde, Vinnie; Ebertseder, Florian; Fernández, Belén; Ficara, Elena; Fotidis, Ioannis; Frigon, Jean-Claude; de Laclos, Hélène Fruteau; Ghasimi, Dara S M; Hack, Gabrielle; Hartel, Mathias; Heerenklage, Joern; Horvath, Ilona Sarvari; Jenicek, Pavel; Koch, Konrad; Krautwald, Judith; Lizasoain, Javier; Liu, Jing; Mosberger, Lona; Nistor, Mihaela; Oechsner, Hans; Oliveira, João Vítor; Paterson, Mark; Pauss, André; Pommier, Sébastien; Porqueddu, Isabella; Raposo, Francisco; Ribeiro, Thierry; Rüsch Pfund, Florian; Strömberg, Sten; Torrijos, Michel; van Eekert, Miriam; van Lier, Jules; Wedwitschka, Harald; Wierinck, Isabella

    2016-12-01

    Production of biogas from different organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist, inter-laboratory tests regularly show high variability of BMPs for the same substrate. A workshop was held in June 2015, in Leysin, Switzerland, with over 40 attendees from 30 laboratories around the world, to agree on common solutions to the conundrum of inconsistent BMP test results. This paper presents the consensus of the intense roundtable discussions and cross-comparison of methodologies used in respective laboratories. Compulsory elements for the validation of BMP results were defined. They include the minimal number of replicates, the request to carry out blank and positive control assays, a criterion for the test duration, details on BMP calculation, and last but not least criteria for rejection of the BMP tests. Finally, recommendations on items that strongly influence the outcome of BMP tests such as inoculum characteristics, substrate preparation, test setup, and data analysis are presented to increase the probability of obtaining validated and reproducible results.

  13. Key results of battery performance and life tests at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1991-12-01

    Advanced battery technology evaluations are performed under simulated electric vehicle operating conditions at Argonne National Laboratory's & Diagnostic Laboratory (ADL). The ADL provide a common basis for both performance characterization and life evaluation with unbiased application of tests and analyses. This paper summarizes the performance characterizations and life evaluations conducted in 1991 on twelve single cells and eight 3- to 360-cell modules that encompass six battery technologies (Na/S, Li/MS, Ni/MH, Zn/Br, Ni/Fe, and Pb-Acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division. The results measure progress in battery R & D programs, compare battery technologies, and provide basic data for modeling and continuing R & D to battery users, developers, and program managers.

  14. Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures

    PubMed Central

    Angst, Ueli M.; Boschmann, Carolina; Wagner, Matthias; Elsener, Bernhard

    2017-01-01

    The aging of reinforced concrete infrastructure in developed countries imposes an urgent need for methods to reliably assess the condition of these structures. Corrosion of the embedded reinforcing steel is the most frequent cause for degradation. While it is well known that the ability of a structure to withstand corrosion depends strongly on factors such as the materials used or the age, it is common practice to rely on threshold values stipulated in standards or textbooks. These threshold values for corrosion initiation (Ccrit) are independent of the actual properties of a certain structure, which clearly limits the accuracy of condition assessments and service life predictions. The practice of using tabulated values can be traced to the lack of reliable methods to determine Ccrit on-site and in the laboratory. Here, an experimental protocol to determine Ccrit for individual engineering structures or structural members is presented. A number of reinforced concrete samples are taken from structures and laboratory corrosion testing is performed. The main advantage of this method is that it ensures real conditions concerning parameters that are well known to greatly influence Ccrit, such as the steel-concrete interface, which cannot be representatively mimicked in laboratory-produced samples. At the same time, the accelerated corrosion test in the laboratory permits the reliable determination of Ccrit prior to corrosion initiation on the tested structure; this is a major advantage over all common condition assessment methods that only permit estimating the conditions for corrosion after initiation, i.e., when the structure is already damaged. The protocol yields the statistical distribution of Ccrit for the tested structure. This serves as a basis for probabilistic prediction models for the remaining time to corrosion, which is needed for maintenance planning. This method can potentially be used in material testing of civil infrastructures, similar to established methods used for mechanical testing. PMID:28892023

  15. Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures.

    PubMed

    Angst, Ueli M; Boschmann, Carolina; Wagner, Matthias; Elsener, Bernhard

    2017-08-31

    The aging of reinforced concrete infrastructure in developed countries imposes an urgent need for methods to reliably assess the condition of these structures. Corrosion of the embedded reinforcing steel is the most frequent cause for degradation. While it is well known that the ability of a structure to withstand corrosion depends strongly on factors such as the materials used or the age, it is common practice to rely on threshold values stipulated in standards or textbooks. These threshold values for corrosion initiation (Ccrit) are independent of the actual properties of a certain structure, which clearly limits the accuracy of condition assessments and service life predictions. The practice of using tabulated values can be traced to the lack of reliable methods to determine Ccrit on-site and in the laboratory. Here, an experimental protocol to determine Ccrit for individual engineering structures or structural members is presented. A number of reinforced concrete samples are taken from structures and laboratory corrosion testing is performed. The main advantage of this method is that it ensures real conditions concerning parameters that are well known to greatly influence Ccrit, such as the steel-concrete interface, which cannot be representatively mimicked in laboratory-produced samples. At the same time, the accelerated corrosion test in the laboratory permits the reliable determination of Ccrit prior to corrosion initiation on the tested structure; this is a major advantage over all common condition assessment methods that only permit estimating the conditions for corrosion after initiation, i.e., when the structure is already damaged. The protocol yields the statistical distribution of Ccrit for the tested structure. This serves as a basis for probabilistic prediction models for the remaining time to corrosion, which is needed for maintenance planning. This method can potentially be used in material testing of civil infrastructures, similar to established methods used for mechanical testing.

  16. Clinical presentation of Lyme disease in the higher-risk region of Quebec: a retrospective descriptive study.

    PubMed

    Charbonneau, Audrey; Charette, Louis-Philippe; Rouleau, Geneviève; Savary, Mélissa; Wilson, Alexandra; Heer, Emily; Bériault, Karine; de Pokomandy, Alexandra

    2018-03-23

    Lyme disease is emerging in Canada. This study aimed to describe the use of serologic testing for the disease in the La Pommeraie health region in southern Quebec between 2012 and 2015 and to describe the clinical presentation of laboratory-confirmed cases. The medical charts of all patients investigated for Lyme disease at the Brome-Missisquoi-Perkins Hospital's laboratory between 2012 and 2015 were reviewed for results of serologic testing. Laboratory diagnosis was based on 2-tiered testing: cases had to have positive results of both the enzyme immunoassay and the Western blot test (IgM or IgG). We collected data on clinical presentation for patients assessed at the hospital or at the La Pommeraie Family Medicine Unit. Over the study period, 720 patients were investigated for Lyme disease. There was a more than fivefold increase in requests for serologic testing from 2012 (53) to 2015 (273). The number of confirmed cases increased from 2012 (3) to 2013 (19) and remained stable thereafter (19 in 2014, 18 in 2015). Fifty patients were positive for IgM with or without IgG positivity, and 9 patients were IgG-positive only. Chart reviews were completed for 278 of the 720 patients, including 38 of the 59 laboratory-confirmed cases. Among the 29 IgM-positive patients, the most common symptoms were fever (17 patients [59%]), fatigue (14 [48%]), myalgia (12 [41%]) and headaches (10 [34%]). Twenty-three (79%) had some cutaneous manifestation, including specifically erythema migrans (14 [48%]). A tick bite was reported by 11 patients (38%). Of the 44 patients in the entire study population who presented with erythema migrans, 15 (34%) had confirmed Lyme disease. Requests for serologic testing for Lyme disease increased in the La Pommeraie health region over recent years. Cutaneous manifestations, fever and myalgia were the most common symptoms of IgM-positive cases. Most patients did not report a tick bite. Copyright 2018, Joule Inc. or its licensors.

  17. Clinical presentation of Lyme disease in the higher-risk region of Quebec: a retrospective descriptive study

    PubMed Central

    Charbonneau, Audrey; Charette, Louis-Philippe; Rouleau, Geneviève; Savary, Mélissa; Wilson, Alexandra; Heer, Emily; Bériault, Karine; de Pokomandy, Alexandra

    2018-01-01

    Background: Lyme disease is emerging in Canada. This study aimed to describe the use of serologic testing for the disease in the La Pommeraie health region in southern Quebec between 2012 and 2015 and to describe the clinical presentation of laboratory-confirmed cases. Methods: The medical charts of all patients investigated for Lyme disease at the Brome-Missisquoi-Perkins Hospital's laboratory between 2012 and 2015 were reviewed for results of serologic testing. Laboratory diagnosis was based on 2-tiered testing: cases had to have positive results of both the enzyme immunoassay and the Western blot test (IgM or IgG). We collected data on clinical presentation for patients assessed at the hospital or at the La Pommeraie Family Medicine Unit. Results: Over the study period, 720 patients were investigated for Lyme disease. There was a more than fivefold increase in requests for serologic testing from 2012 (53) to 2015 (273). The number of confirmed cases increased from 2012 (3) to 2013 (19) and remained stable thereafter (19 in 2014, 18 in 2015). Fifty patients were positive for IgM with or without IgG positivity, and 9 patients were IgG-positive only. Chart reviews were completed for 278 of the 720 patients, including 38 of the 59 laboratory-confirmed cases. Among the 29 IgM-positive patients, the most common symptoms were fever (17 patients [59%]), fatigue (14 [48%]), myalgia (12 [41%]) and headaches (10 [34%]). Twenty-three (79%) had some cutaneous manifestation, including specifically erythema migrans (14 [48%]). A tick bite was reported by 11 patients (38%). Of the 44 patients in the entire study population who presented with erythema migrans, 15 (34%) had confirmed Lyme disease. Interpretation: Requests for serologic testing for Lyme disease increased in the La Pommeraie health region over recent years. Cutaneous manifestations, fever and myalgia were the most common symptoms of IgM-positive cases. Most patients did not report a tick bite. PMID:29588280

  18. Testing a common ice-ocean parameterization with laboratory experiments

    NASA Astrophysics Data System (ADS)

    McConnochie, C. D.; Kerr, R. C.

    2017-07-01

    Numerical models of ice-ocean interactions typically rely upon a parameterization for the transport of heat and salt to the ice face that has not been satisfactorily validated by observational or experimental data. We compare laboratory experiments of ice-saltwater interactions to a common numerical parameterization and find a significant disagreement in the dependence of the melt rate on the fluid velocity. We suggest a resolution to this disagreement based on a theoretical analysis of the boundary layer next to a vertical heated plate, which results in a threshold fluid velocity of approximately 4 cm/s at driving temperatures between 0.5 and 4°C, above which the form of the parameterization should be valid.

  19. Analysis of current thyroid function test ordering practices.

    PubMed

    Kluesner, Joseph K; Beckman, Darrick J; Tate, Joshua M; Beauvais, Alexis A; Kravchenko, Maria I; Wardian, Jana L; Graybill, Sky D; Colburn, Jeffrey A; Folaron, Irene; True, Mark W

    2018-04-01

    Current guidelines recommend thyroid stimulating hormone (TSH) alone as the best test to detect and monitor thyroid dysfunction, yet free thyroxine (FT4) and free triiodothyronine (FT3) are commonly ordered when not clinically indicated. Excessive testing can lead to added economic burden in an era of rising healthcare costs, while rarely contributing to the evaluation or management of thyroid disease. To evaluate our institution's practice in ordering thyroid function tests (TFTs) and to identify strategies to reduce inappropriate FT4 and FT3 testing. A record of all TFTs obtained in the San Antonio Military Health System during a 3-month period was extracted from the electronic medical record. The TFTs of interest were TSH, FT4, thyroid panel (TSH + FT4), FT3, total thyroxine (T4), and total triiodothyronine (T3). These were categorized based on the presence or absence of hypothyroidism. Between August 1 and October 31, 2016, there were 38 214 individual TFTs ordered via 28 597 total laboratory requests; 11 486 of these requests were in patients with a history of hypothyroidism. The number (percent) of laboratory requests fell into these patterns: TSH alone 14 919 (52.14%), TSH + FT4 7641 (26.72%), FT3 alone 3039 (10.63%), FT4 alone 1219 (4.26%), TSH + FT4 + FT3 783 (2.74%), and others 996 (3.48%); 36.0% of TFTs ordered were free thyroid hormones. Projected out to a year, using Department of Defense laboratory costs, $317 429 worth of TFTs would be ordered, with free thyroid hormone testing accounting for $107 720. Inappropriate ordering of free thyroid hormone tests is common. In an era of rising healthcare costs, inappropriate thyroid function testing is an ideal target for efforts to reduce laboratory overutilization, which in our system, could save up to $120 000 per year. Further evaluation is needed to determine strategies that can reduce excessive thyroid hormone testing. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  20. First proficiency testing to evaluate the ability of European Union National Reference Laboratories to detect staphylococcal enterotoxins in milk products.

    PubMed

    Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane

    2003-01-01

    The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.

  1. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    PubMed

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  2. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

    PubMed

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-03-26

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

  3. Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population

    PubMed Central

    Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea

    2016-01-01

    Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800

  4. Laboratory evaluations of erectile dysfunction: an evidence based approach.

    PubMed

    Bodie, Joshua; Lewis, Jean; Schow, Doug; Monga, Manoj

    2003-06-01

    We evaluate the prevalence of laboratory abnormalities in men presenting for initial evaluation and therapy of erectile dysfunction. The computerized charts of men receiving treatment for erectile dysfunction from 1987 to 2002 were retrospectively reviewed. We pooled laboratory data for 3,547 men with erectile dysfunction to assess the prevalence of laboratory abnormalities. Values of the common laboratory screening tests for erectile dysfunction were recorded for testosterone, prolactin, luteinizing hormone, thyroid-stimulating hormone, hemoglobin A(Ic), prostate specific antigen, hemoglobin, cholesterol and creatinine. Of those patients evaluated 18.7% had low testosterone, 4.6% had increased prolactin, 14.6% had abnormal luteinizing hormone, 4.0% had increased thyroid-stimulating hormone, 8.3% had increased prostate specific antigen, 26.5% had anemia and 11.9% tested had renal insufficiency. A high percentage of patients presenting with a primary complaint of erectile dysfunction had increased hemoglobin A(Ic) and total serum cholesterol levels (52.9% and 48.4%, respectively). An evidence based approach to standardization of laboratory evaluations for men presenting with erectile dysfunction is recommended. Laboratory screening should be directed to identify those risk factors that may benefit from lifestyle modification and pharmacological intervention.

  5. Sickle-Cell Disease in Nigerian Children: Parental Knowledge and Laboratory Results.

    PubMed

    Obaro, Stephen K; Daniel, Yvonne; Lawson, Juliana O; Hsu, Wei-Wei; Dada, John; Essen, Uduak; Ibrahim, Khalid; Akindele, Adebayo; Brooks, Kevin; Olanipekun, Grace; Ajose, Theresa; Stewart, Claire E; Inusa, Baba P D

    2016-01-01

    Sickle-cell disease (SCD) is the most common inherited genetic disorder in sub-Saharan Africa, and it is associated with early mortality and lifelong morbidity. Early diagnosis is essential for instituting appropriate care and preventive therapy. To compare parental knowledge or perception of their offspring's hemoglobin phenotype prior to testing and actual validated laboratory test results. In a prospective community-based survey, we assessed parental knowledge of their children's hemoglobin phenotype and corroborated this with the results from a laboratory confirmatory test determined by high-performance liquid chromatography. We screened 10,126 children aged less than 5 years. A total of 163 (1.6%) parents indicated that their offspring had been previously tested and had knowledge of the child's hemoglobin genotype. However, 51 (31.2%) of 163 parents of children who had been previously tested did not know the result of their offspring's test, and 18 (35.3%) of these 51 children were found to have SCD. Of those who claimed previous knowledge, 25 (15.3%) of 163 reported incorrect results. Overall, we identified 272 (2.76%) new cases from 9,963 children who had not been previously tested. There is the need to promote public awareness about SCD and the benefit of early diagnosis, quality assurance in laboratory diagnosis and institution of sustainable patient care pathways. © 2016 S. Karger AG, Basel.

  6. Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

    NASA Technical Reports Server (NTRS)

    Bivolaru, Daniel; Lee, Joseph W.; Jones, Stephen B.; Tedder, Sarah A.; Danehy, Paul M.; Weikl, M. C.; Magnotti, G.; Cutler, Andrew D.

    2007-01-01

    This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

  7. Ehrlichiosis, Babesiosis, Anaplasmosis and Hepatozoonosis in Dogs from St. Kitts, West Indies

    PubMed Central

    Kelly, Patrick J.; Xu, Chuanling; Lucas, Helene; Loftis, Amanda; Abete, Jamie; Zeoli, Frank; Stevens, Audrey; Jaegersen, Kirsten; Ackerson, Kate; Gessner, April; Kaltenboeck, Bernhard; Wang, Chengming

    2013-01-01

    Background Although tick-borne diseases are important causes of morbidity and mortality in dogs in tropical areas, there is little information on the agents causing these infections in the Caribbean. Methodology We used PCRs to test blood from a cross-section of dogs on St Kitts for Ehrlichia (E.) canis, Babesia (B.) spp., Anaplasma (A.) spp. and Hepatozoon (H.) spp. Antibodies against E. canis and A. phagocytophilum/platys were detected using commercial immunochromatography tests. Records of the dogs were examined retrospectively to obtain clinical and laboratory data. Principal findings There was serological and/or PCR evidence of infections of dogs with E. canis (27%; 46/170), Babesia spp. (24%; 90/372) including B. canis vogeli (12%; 43/372) and B. gibsoni (10%; 36/372), A. platys (11%; 17/157) and H. canis (6%; 15/266). We could not identify the Babesia sp. detected in nine dogs. There was evidence of multiple infections with dual infections with E. canis and B. canis vogeli (8%; 14/179) or B. gibsoni (7%; 11/170) being the most common. There was agreement between immunochromatography and PCR test results for E. canis for 87% of dogs. Only 13% of exposed dogs had signs of a tick-borne disease and 38% had laboratory abnormalities. All 10 dogs presenting for a recheck after treatment of E. canis with doxycycline were apparently healthy although all remained seropositive and six still had laboratory abnormalities despite an average of two treatments with the most recent being around 12 months previously. Infections with Babesia spp. were also mainly subclinical with only 6% (4/67) showing clinical signs and 13% (9/67) having laboratory abnormalities. Similarly, animals with evidence of infections with A. platys and H. canis were largely apparently healthy with only occasional laboratory abnormalities. Conclusions Dogs are commonly infected with tick-borne pathogens in the Caribbean with most having no clinical signs or laboratory abnormalities. PMID:23335965

  8. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains.

    PubMed

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-05-01

    Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Glucose-6-phosphate dehydrogenase laboratory assay: How, when, and why?

    PubMed

    Minucci, Angelo; Giardina, Bruno; Zuppi, Cecilia; Capoluongo, Ettore

    2009-01-01

    Glucose 6-phosphate dehydrogenase (G6PD) deficiency is the most common defect of red blood cells. Although some different laboratory techniques or methods are employed for the biochemical screening, a strict relationship between biochemists, clinicians, and molecular biologists is necessary for a definitive diagnosis. This article represents an overview on the current laboratory tests finalized to the screening or to the definitive diagnosis of G6PD-deficiency, underlying the problems regarding the biochemical and molecular identification of heterozygote females other than those regarding the standardization of the clinical and laboratory diagnostic procedures. Finally, this review is aimed to give a flow-chart for the complete diagnostic approach of G6PD-deficiency.

  10. Effect of implementing instructional videos in a physical examination course: an alternative paradigm for chiropractic physical examination teaching.

    PubMed

    Zhang, Niu; Chawla, Sudeep

    2012-01-01

    This study examined the effect of implementing instructional video in ophthalmic physical examination teaching on chiropractic students' laboratory physical examination skills and written test results. Instructional video clips of ophthalmic physical examination, consisting of both standard procedures and common mistakes, were created and used for laboratory teaching. The video clips were also available for student review after class. Students' laboratory skills and written test results were analyzed and compared using one-way analysis of variance (ANOVA) and post hoc multiple comparison tests among three study cohorts: the comparison cohort who did not utilize the instructional videos as a tool, the standard video cohort who viewed only the standard procedure of video clips, and the mistake-referenced video cohort who viewed video clips containing both standard procedure and common mistakes. One-way ANOVA suggested a significant difference of lab results among the three cohorts. Post hoc multiple comparisons further revealed that the mean scores of both video cohorts were significantly higher than that of the comparison cohort (p < .001). There was, however, no significant difference of the mean scores between the two video cohorts (p > .05). However, the percentage of students having a perfect score was the highest in the mistake-referenced video cohort. There was no significant difference of written test scores among all three cohorts (p > .05). The instructional video of the standard procedure improves chiropractic students' ophthalmic physical examination skills, which may be further enhanced by implementing a mistake-referenced instructional video.

  11. Knowledge and Practices of Toxoplasmosis among Clinical Laboratory Professionals: A Cross-Sectional Study in Durango, Mexico.

    PubMed

    Alvarado-Esquivel, Cosme; Sánchez-Anguiano, Luis Francisco; Berumen-Segovia, Luis Omar; Hernández-Tinoco, Jesús; Rico-Almochantaf, Yazmin Del Rosario; Cisneros-Camacho, Alfredo; Cisneros-Martínez, Jorge Arturo

    2017-11-18

    Background : The aim of this study was to determine the level of knowledge and practices about toxoplasmosis in a sample of clinical laboratory professionals in Mexico. Methods : 192 clinical laboratory professionals were surveyed. They were asked about (1) Toxoplasma gondii ; (2) clinical manifestations, diagnosis, treatment, and epidemiology of toxoplasmosis; and (3) their practices with respect to toxoplasmosis. Results : The range of animals infected by T. gondii was known by 44.8% of participants. Clinical aspects of toxoplasmosis were known by up to 44.3% of subjects. Correct answers about the interpretation of serological markers of T. gondii infection were provided by up to 32.8% of participants. A minority (32.2%) of participants knew about a high number of false positive results of anti- T. gondii IgM antibody tests. Most participants (90.1%) did not know what the anti- T. gondii IgG avidity test was. Up to 55.7% of participants provided incorrect answers about the interpretation of serology tests for the treatment of pregnant women. Common routes of T. gondii infection were known by <15% of participants. Most (84.4%) participants had not performed tests for detection T. gondii infection. Conclusions : Results indicate incomplete knowledge of T. gondii infection and toxoplasmosis and a limited practice of laboratory tests among the professionals surveyed.

  12. Using fee-for-service testing to generate revenue for the 21st century public health laboratory.

    PubMed

    Loring, Carol; Neil, R Brock; Gillim-Ross, Laura; Bashore, Matthew; Shah, Sandip

    2013-01-01

    The decrease in appropriations for state public health laboratories (SPHLs) has become a major concern as tax revenues and, subsequently, state and federal funding, have decreased. These reductions have forced SPHLs to pursue revenue-generating opportunities to support their work. We describe the current state of funding in a sampling of SPHLs and the challenges these laboratories face as they implement or expand fee-for-service testing. We conducted surveys of SPHLs to collect data concerning laboratory funding sources, test menus, fee-for-service testing, and challenges to implementing fee-for-service testing. Most SPHLS receive funding through three revenue sources: state appropriation, federal funding, and fee-for-service testing (cash funds). Among SPHLs, state appropriations ranged from $0 to more than $6 per capita, federal funding ranged from $0.10 to $5 per capita, and revenue from fee-for-service testing ranged from $0 to $4 per capita. The tests commonly performed on a fee-for-service basis included assays for sexually transmitted diseases, mycobacterial cultures, newborn screening, and water testing. We found that restrictive legislation, staffing shortages, inadequate software for billing fee-for-service testing, and regulations on how SPHLs use their generated revenue are impediments to implementing fee-for-service testing. Some SPHLs are considering implementing or expanding fee-for-service testing as a way to recapture funds lost as a result of state and federal budget cuts. This analysis revealed many of the obstacles to implementing fee-for-service testing in SPHLs and the potential impact on SPHLs of continued decreases in funding.

  13. [Laboratory study of the cytotoxicity of colored soft contact lenses].

    PubMed

    Almesmary, A A

    1999-01-01

    In the clinical practice we have met with the fact that some patients did not tolerate soft coloured contact lenses even when they used them for a short time. To find whether the cause is the composition of these lenses, mainly the adding of stain, he used the laboratory test to determine cytotoxicity, the test of dynamic observation of cytotoxicity where the cells cultured in vitro are the experimental object. On the basis of the results of this test commonly used for the determination of the cytotoxicity of implantation materials, he thinks that the cause of intolerance of coloured lenses is not their toxicity but other phenomena. An individual hypersensitivity or insufficient care of lenses (the influence of disinfectants) can be among these causes.

  14. Analysis of fungal type isolates taken from a 90-day manned test of an advanced regenerative life support system

    NASA Technical Reports Server (NTRS)

    Sofios, M.; Swatek, F. E.

    1972-01-01

    Fungal-like cultures isolated before, during, and after the 90-day test from samples of space station simulator (SSS) atmosphere, surfaces, subsystem componets, and crew dermal sites were identified to genus. Out of the original 525 isolates, approximately 80% were classified as bacteria. Laboratory methods (culture media, moisturization, and incubation temperatures) favored the recovery of medically significant bacteria rather than fungi. Therefore, fungal isolates were mostly, nonfastidious types which are ubiquitous in soil and air and commonly contaminate laboratory cultures of pathogens. Predominant isolates were species of Aspergillus, Penicillium, Pullularia, Rhodotorula, and various yeasts. No instances of fungal proliferation were observed; test data reflect the survival of environmental types indigenous to the SSS pretests.

  15. Pathology consultation on urine compliance testing and drug abuse screening.

    PubMed

    Ward, Michael B; Hackenmueller, Sarah A; Strathmann, Frederick G

    2014-11-01

    Compliance testing in pain management requires a distinct approach compared with classic clinical toxicology testing. Differences in the patient populations and clinical expectations require modifications to established reporting cutoffs, assay performance expectations, and critical review of how best to apply the available testing methods. Although other approaches to testing are emerging, immunoassay screening followed by mass spectrometry confirmation remains the most common testing workflow for pain management compliance and drug abuse testing. A case-based approach was used to illustrate the complexities inherent to and uniqueness of pain management compliance testing for both clinicians and laboratories. A basic understanding of the inherent strengths and weaknesses of immunoassays and mass spectrometry provides the clinician a better understanding of how best to approach pain management compliance testing. Pain management compliance testing is a textbook example of an emerging field requiring open communication between physician and performing laboratory to fully optimize patient care. Copyright© by the American Society for Clinical Pathology.

  16. Sesquicentennial of the birth of Edmund Faustinus Biernacki, a discoverer of the erythrocyte sedimentation rate.

    PubMed

    Kucharz, Eugeniusz J

    2017-01-01

    Edmund Faustinus Biernacki (1866-1911) was a Polish physician and philosopher of medicine. He described erythrocyte sedimentation, designed equipment to measure the erythrocyte sedimentation rate, and applied it to clinical practice. His contribution to the development of one of the most commonly used medical laboratory tests is forgotten, and the test is attributed to other scientists.

  17. Diagnostic sampling and gross pathology of New World camelids.

    PubMed

    Bildfell, Robert J; Löhr, Christiane V; Tornquist, Susan J

    2012-11-01

    This article provides an overview of tests and appropriate samples to send to a Veterinary Diagnostic Laboratory for the diagnosis of common diseases of New World Camelids (NWC) such as abortions, congenital anomalies, anemia, enteritis, endoparasitism, gastric ulcer, hepatic lipidosis, encephalitis, pneumonia, dermatosis, neoplasia and cryptococcosis. Unique anatomic features of NWC and common findings encountered during gross necropsy examination are briefly reviewed. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Current status of verification practices in clinical biochemistry in Spain.

    PubMed

    Gómez-Rioja, Rubén; Alvarez, Virtudes; Ventura, Montserrat; Alsina, M Jesús; Barba, Núria; Cortés, Mariano; Llopis, María Antonia; Martínez, Cecilia; Ibarz, Mercè

    2013-09-01

    Verification uses logical algorithms to detect potential errors before laboratory results are released to the clinician. Even though verification is one of the main processes in all laboratories, there is a lack of standardization mainly in the algorithms used and the criteria and verification limits applied. A survey in clinical laboratories in Spain was conducted in order to assess the verification process, particularly the use of autoverification. Questionnaires were sent to the laboratories involved in the External Quality Assurance Program organized by the Spanish Society of Clinical Biochemistry and Molecular Pathology. Seven common biochemical parameters were included (glucose, cholesterol, triglycerides, creatinine, potassium, calcium, and alanine aminotransferase). Completed questionnaires were received from 85 laboratories. Nearly all the laboratories reported using the following seven verification criteria: internal quality control, instrument warnings, sample deterioration, reference limits, clinical data, concordance between parameters, and verification of results. The use of all verification criteria varied according to the type of verification (automatic, technical, or medical). Verification limits for these parameters are similar to biological reference ranges. Delta Check was used in 24% of laboratories. Most laboratories (64%) reported using autoverification systems. Autoverification use was related to laboratory size, ownership, and type of laboratory information system, but amount of use (percentage of test autoverified) was not related to laboratory size. A total of 36% of Spanish laboratories do not use autoverification, despite the general implementation of laboratory information systems, most of them, with autoverification ability. Criteria and rules for seven routine biochemical tests were obtained.

  19. Proficiency testing of Hb A1c: a 4-year experience in Taiwan and the Asian Pacific region.

    PubMed

    Shiesh, Shu-Chu; Wiedmeyer, Hsiao-Mei; Kao, Jau-Tsuen; Vasikaran, Samuel D; Lopez, Joseph B

    2009-10-01

    The correlation between hemoglobin A(1c) (Hb A(1c)) and risk for complications in diabetic patients heightens the need to measure Hb A(1c) with accuracy. We evaluated the current performance for measuring Hb A(1c) in the Asian and Pacific region by examining data submitted by laboratories participating in the Taiwan proficiency-testing program. Five fresh-pooled blood samples were sent to participating laboratories twice each year. The results were evaluated against target values assigned by the National Glycohemoglobin Standardization Program network laboratories; a passing criterion of +/-7% of the target value was used. Measurement uncertainty at Hb A(1c) concentrations of 7.0% and 8.0% were determined. A total of 276 laboratories from 11 countries took part in the Hb A(1c) survey. At the Hb A(1c) concentrations tested method-specific interlaboratory imprecision (CVs) were 1.1%-13.9% in 2005, 1.3%-10.1% in 2006, 1.2%-8.2% in 2007, and 1.1%-6.1% in 2008. Differences between target values and median values from the commonly used methods ranged from -0.24% to 0.22% Hb A(1c) in 2008. In 2005 83% of laboratories passed the survey, and in 2008 93% passed. At 7.0% Hb A(1c), measurement uncertainty was on average 0.49% Hb A(1c). The use of accuracy-based proficiency testing with stringent quality criteria has improved the performance of Hb A(1c) testing in the Asian and Pacific laboratories during the 4 years of assessment.

  20. The role of laboratory testing in detection and classification of chronic kidney disease: national recommendations

    PubMed Central

    Biljak, Vanja Radišić; Honović, Lorena; Matica, Jasminka; Krešić, Branka; Vojak, Sanela Šimić

    2017-01-01

    Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuria). Therefore, the joint working group of the Croatian society of medical biochemistry and laboratory medicine and Croatian chamber of medical biochemists for laboratory diagnostics in CKD issued this national recommendation regarding laboratory diagnostics of CKD.
Key factors for laboratories implementing the national guidelines for the diagnosis and management of CKD are:
1. Ensure good communication between laboratory professionals and clinicians, such as nephrologists or specialists in general/family medicine,
2. Ensure all patients are provided with the same availability of laboratory diagnostics,
3. Ensure creatinine assays are traceable to isotope dilution mass spectrometry (IDMS) method and have minimal bias and acceptable imprecision,
4. Select the appropriate GFR estimating formula. Recommended equation is the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD – EPI) equation,
5. In reporting the key laboratory tests (creatinine, eGFR, urine albumin-to-creatinine ratio, urine protein-to-creatinine ratio) use the appropriate reporting units,
6. Provide adequate information on limitations of creatinine measurement.
The manuscript has been organized to identify critical points in laboratory tests used in basic laboratory diagnostics of CKD and is based on the Kidney Disease: Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. PMID:28392738

  1. Competency assessment of microbiology medical laboratory technologists in Ontario, Canada.

    PubMed

    Desjardins, Marc; Fleming, Christine Ann

    2014-08-01

    Accreditation in Ontario, Canada, requires that licensed clinical laboratories participate in external quality assessment (also known as proficiency testing) and perform competency evaluation of their staff. To assess the extent of ongoing competency assessment practices, the Quality Management Program--Laboratory Services (QMP-LS) Microbiology Committee surveyed all 112 licensed Ontario microbiology laboratories. The questionnaire consisted of a total of 21 questions that included yes/no, multiple-choice, and short-answer formats. Participants were asked to provide information about existing programs, the frequency of testing, what areas are evaluated, and how results are communicated to the staff. Of the 111 responding laboratories, 6 indicated they did not have a formal evaluation program since they perform only limited bacteriology testing. Of the remaining 105 respondents, 87% perform evaluations at least annually or every 2 years, and 61% include any test or task performed, whereas 16% and 10% focus only on problem areas and high-volume complex tasks, respectively. The most common methods of evaluation were review of external quality assessment (EQA) challenges, direct observation, and worksheet review. With the exception of one participant, all communicate results to staff, and most take remedial action to correct the deficiencies. Although most accredited laboratories have a program to assess the ongoing competency of their staff, the methods used are not standardized or consistently applied, indicating that there is room for improvement. The survey successfully highlighted potential areas for improvement and allowed the QMP-LS Microbiology Committee to provide guidance to Ontario laboratories for establishing or improving existing microbiology-specific competency assessment programs. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. Competency Assessment of Microbiology Medical Laboratory Technologists in Ontario, Canada

    PubMed Central

    Fleming, Christine Ann

    2014-01-01

    Accreditation in Ontario, Canada, requires that licensed clinical laboratories participate in external quality assessment (also known as proficiency testing) and perform competency evaluation of their staff. To assess the extent of ongoing competency assessment practices, the Quality Management Program—Laboratory Services (QMP-LS) Microbiology Committee surveyed all 112 licensed Ontario microbiology laboratories. The questionnaire consisted of a total of 21 questions that included yes/no, multiple-choice, and short-answer formats. Participants were asked to provide information about existing programs, the frequency of testing, what areas are evaluated, and how results are communicated to the staff. Of the 111 responding laboratories, 6 indicated they did not have a formal evaluation program since they perform only limited bacteriology testing. Of the remaining 105 respondents, 87% perform evaluations at least annually or every 2 years, and 61% include any test or task performed, whereas 16% and 10% focus only on problem areas and high-volume complex tasks, respectively. The most common methods of evaluation were review of external quality assessment (EQA) challenges, direct observation, and worksheet review. With the exception of one participant, all communicate results to staff, and most take remedial action to correct the deficiencies. Although most accredited laboratories have a program to assess the ongoing competency of their staff, the methods used are not standardized or consistently applied, indicating that there is room for improvement. The survey successfully highlighted potential areas for improvement and allowed the QMP-LS Microbiology Committee to provide guidance to Ontario laboratories for establishing or improving existing microbiology-specific competency assessment programs. PMID:24899030

  3. The Benefits and Challenges of an Interfaced Electronic Health Record and Laboratory Information System: Effects on Laboratory Processes.

    PubMed

    Petrides, Athena K; Bixho, Ida; Goonan, Ellen M; Bates, David W; Shaykevich, Shimon; Lipsitz, Stuart R; Landman, Adam B; Tanasijevic, Milenko J; Melanson, Stacy E F

    2017-03-01

    - A recent government regulation incentivizes implementation of an electronic health record (EHR) with computerized order entry and structured results display. Many institutions have also chosen to interface their EHR with their laboratory information system (LIS). - To determine the impact of an interfaced EHR-LIS on laboratory processes. - We analyzed several different processes before and after implementation of an interfaced EHR-LIS: the turnaround time, the number of stat specimens received, venipunctures per patient per day, preanalytic errors in phlebotomy, the number of add-on tests using a new electronic process, and the number of wrong test codes ordered. Data were gathered through the LIS and/or EHR. - The turnaround time for potassium and hematocrit decreased significantly (P = .047 and P = .004, respectively). The number of stat orders also decreased significantly, from 40% to 7% for potassium and hematocrit, respectively (P < .001 for both). Even though the average number of inpatient venipunctures per day increased from 1.38 to 1.62 (P < .001), the average number of preanalytic errors per month decreased from 2.24 to 0.16 per 1000 specimens (P < .001). Overall there was a 16% increase in add-on tests. The number of wrong test codes ordered was high and it was challenging for providers to correctly order some common tests. - An interfaced EHR-LIS significantly improved within-laboratory turnaround time and decreased stat requests and preanalytic phlebotomy errors. Despite increasing the number of add-on requests, an electronic add-on process increased efficiency and improved provider satisfaction. Laboratories implementing an interfaced EHR-LIS should be cautious of its effects on test ordering and patient venipunctures per day.

  4. A comparison of the MeltPro® HPV Test with the Cobas® HPV Test for detecting and genotyping 14 high-risk human papillomavirus types.

    PubMed

    Tang, Zhiteng; Xu, Ye; Song, Najie; Zou, Dongqing; Liao, Yiqun; Li, Qingge; Pan, Chao

    2018-03-01

    The clinical performance of the newly developed MeltPro ® HPV Test, based on multicolor melting curve analysis, was evaluated and compared with the commercially available Cobas ® HPV Test for detection of HPV and genotyping of HPV-16 and HPV-18. A total of 1647 cervical samples were analyzed with both tests. The agreement values were 96.2% for HPV detection, 99.6% for HPV-16 identification, and 99.7% for HPV-18 identification. All genotyping results from MeltPro ® HPV Test showed that HPV-52, HPV-58, and HPV-16 were the most common types in this study. Intra-laboratory reproducibility studies showed 97.8% agreement while inter-laboratory reproducibility studies showed 96.9% agreement for the MeltPro ® HPV Test. The MeltPro ® HPV Test and Cobas ® HPV Test are highly correlative and are useful for monitoring HPV infection.

  5. Making pH Tangible.

    ERIC Educational Resources Information Center

    McIntosh, Elizabeth; Moss, Robert

    1995-01-01

    Presents a laboratory exercise in which students test the pH of different substances, study the effect of a buffer on acidic solutions by comparing the behavior of buffered and unbuffered solutions upon the addition of acid, and compare common over-the-counter antacid remedies. (MKR)

  6. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    PubMed

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. NASA Langley Research Center's Simulation-To-Flight Concept Accomplished through the Integration Laboratories of the Transport Research Facility

    NASA Technical Reports Server (NTRS)

    Martinez, Debbie; Davidson, Paul C.; Kenney, P. Sean; Hutchinson, Brian K.

    2004-01-01

    The Flight Simulation and Software Branch (FSSB) at NASA Langley Research Center (LaRC) maintains the unique national asset identified as the Transport Research Facility (TRF). The TRF is a group of facilities and integration laboratories utilized to support the LaRC's simulation-to-flight concept. This concept incorporates common software, hardware, and processes for both groundbased flight simulators and LaRC s B-757-200 flying laboratory identified as the Airborne Research Integrated Experiments System (ARIES). These assets provide Government, industry, and academia with an efficient way to develop and test new technology concepts to enhance the capacity, safety, and operational needs of the ever-changing national airspace system. The integration of the TRF enables a smooth continuous flow of the research from simulation to actual flight test.

  8. Forensic science: the truth is out there

    NASA Astrophysics Data System (ADS)

    Herold, Lynne D.

    2002-06-01

    Criminalistics, one of the many sub-divisions of forensic science, is an applied science in which items of evidence are analyzed to provide investigative information and scientific evidence to be used in courts of law. Laboratories associated with governmental public agencies are typically involved in criminal cases as opposed to civil cases, and those types of cases that fall within the jurisdiction of the particular agency. Common analytical divisions within criminalistics laboratories include blood alcohol testing, toxicology, narcotics, questioned documents, biology, firearms, latent fingerprints, physical and trace evidence sections. Specialized field investigative services may be provided in the areas of clandestine drug laboratories and major crimes (firearms, biology, trace, arson/explosives). Forensic science best practice requires the use of non-destructive testing whenever reasonably possible. Several technically difficult situations (bodies and evidence encased in cement and metal) are presented as a challenge to audience.

  9. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  10. Variations in biochemical values for common laboratory tests: a comparison among multi-ethnic Israeli women cohort.

    PubMed

    Birk, Ruth; Heifetz, Eliyahu M

    2018-04-28

    Biochemical laboratory values are an essential tool in medical diagnosis, treatment, and follow-up; however, they are known to vary between populations. Establishment of ethnicity-adjusted reference values is recommended by health organizations. To investigate the ethnicity element in biochemical lab values studying women of different ethnic groups. Biochemical lab values (n = 27) of 503 adult Israeli women of three ethnicities (Jewish Ashkenazi, Jewish Sephardic, and Bedouin Arab) attending a single medical center were analyzed. Biochemical data were extracted from medical center records. Ethnic differences of laboratory biochemicals were studied using ANCOVA to analyze the center of the distribution as well as quartile regression analysis to analyze the upper and lower limits, both done with an adjustment for age. Significant ethnic differences were found in almost half (n = 12) of the biochemical laboratory tests. Ashkenazi Jews exhibited significantly higher mean values compared to Bedouins in most of the biochemical tests, including albumin, alkaline phosphatase, calcium, cholesterol, cholesterol LDL and HDL, cholesterol LDL calc., folic acid, globulin, and iron saturation, while the Bedouins exhibited the highest mean values in the creatinine and triglycerides. For most of these tests, Sephardic Jews exhibited biochemical mean levels in between the two other groups. Compared to Ashkenazi Jews, Sephardic Jews had a significant shift to lower values in cholesterol LDL. Ethnic subpopulations have distinct distributions in biochemical laboratory test values, which should be taken into consideration in medical practice enabling precision medicine.

  11. Pin on disk against ball on disk for the evaluation of wear improvement on cryo-treated metal cutting shears

    NASA Astrophysics Data System (ADS)

    Jimbert, P.; Iturrondobeitia, M.; Ibarretxe, J.; Fernandez-Martinez, R.

    2015-03-01

    When talking about trybology, the election of the laboratory experiment type is a common problem of discussion. Laboratory wear methods are not designed to exactly reproduce the real working conditions of the analyzed part itself but serve to engineers and researcher to extrapolate the laboratory results to the real application. In order to shed some light on this issue, two wear tests have been analyzed following an ASTM standard and using the same experimental parameters and testing pair-materials in order to be able to make a comparison: Pin-on-Disk (PoD) against Ball-on-Disk (BoD). Three different tool steel have been analyzed in this study, AISI D2, AISI A8 and AISI H13, used to produce metal cutting shears. Metal on metal dry sliding tests were designed in order to reproduce the tool working conditions. These three materials were cryogenically treated and compared against no cryogenically treated ones to measure the improvement on their wear resistance due to cryogenic treatment. Finally, the wear rates obtained with both laboratory tests were compared against some real production metal cutting tools wear data. Results revealed an improvement of the wear resistance for cryo-treated samples of around 20% with the BoD test and around 6% with the PoD test. Real production tools wear was calculated for one of the tool steels and for two different applications. The improvement was approximately the one revealed by the BoD test. So, for the studied case, the BoD laboratory test gives more realistic prediction of real tool life improvement due to the cryogenic treatment.

  12. Development of fire test methods for airplane interior materials

    NASA Technical Reports Server (NTRS)

    Tustin, E. A.

    1978-01-01

    Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.

  13. Clinical and Radiological Profile of Acute Fibrinous and Organizing Pneumonia: A Retrospective Study.

    PubMed

    Dai, Jing-Hong; Li, Hui; Shen, Wei; Miao, Li-Yun; Xiao, Yong-Long; Huang, Mei; Cao, Meng-Shu; Wang, Yang; Zhu, Bin; Meng, Fan-Qing; Cai, Hou-Rong

    2015-10-20

    Acute fibrinous and organizing pneumonia (AFOP) is a unique pathological entity with intra-alveolar fibrin in the form of "fibrin balls" and organizing pneumonia. It was divided into rare idiopathic interstitial pneumonia according to the classification notified by American Thoracic Society/European Respiratory Society in 2013. As a rare pathological entity, it is still not well known and recognized by clinicians. We reviewed the clinical features of 20 patients with AFOP diagnosed in a teaching hospital. The medical records of 20 patients with biopsy-proven diagnosis of AFOP were retrospectively reviewed. The patients' symptoms, duration of the disease, comorbidities, clinical laboratory data, pulmonary function testing, radiographic studies, and the response to treatment were extracted and analyzed. Fever was the most common symptom and was manifested in 90% of AFOP patients. For clinical laboratory findings, systematic inflammatory indicators, including C-reactive protein and erythrocyte sedimentation rate, were significantly higher than normal in AFOP patients. In accordance with this increased indicators, injured liver functions were common in AFOP patients. Inversely, AFOP patients had worse clinical conditions including anemia and hypoalbuminemia. For pulmonary function testing, AFOP patients showed the pattern of restrictive mixed with obstructive ventilation dysfunction. For high-resolution computerized tomography (HRCT) findings, the most common pattern for AFOP patients was lobar consolidation which was very similar to pneumonia. However, unlike pneumonia, AFOP patients responded well to glucocorticoids. Patients with AFOP manifest as acute inflammatory-like clinical laboratory parameters and lobar consolidation on HRCT, but respond well to steroid.

  14. Airbags to Martian Landers: Analyses at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gwinn, K.W.

    1994-03-01

    A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, andmore » analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is described as well as a more traditional example Sandia with the test/analysis correlation of the impact of a weapon container.« less

  15. Precursor medications as a source of methamphetamine and/or amphetamine positive drug testing results.

    PubMed

    Cody, John T

    2002-05-01

    Medical Review Officer interpretation of laboratory results is an important component of drug testing programs. The clinical evaluation of laboratory results to assess the possibility of appropriate medical use of a drug is a task with many different facets, depending on the drug class considered. This intercession prevents the reporting of positive results unless it is apparent that drugs were used illicitly. In addition to the commonly encountered prescribed drugs that yield positive drug testing results, other sources of positive results must be considered. This review describes a series of compounds referred to as "precursor" drugs that are metabolized by the body to amphetamine and/or methamphetamine. These compounds lead to positive results for amphetamines even though neither amphetamine nor methamphetamine were used, a possibility that must be considered in the review of laboratory results. Description of the drugs, their clinical indications, and results seen following administration are provided. This information allows for the informed evaluation of results with regard to the potential involvement of these drugs.

  16. Pending laboratory tests and the hospital discharge summary in patients discharged to sub-acute care.

    PubMed

    Walz, Stacy E; Smith, Maureen; Cox, Elizabeth; Sattin, Justin; Kind, Amy J H

    2011-04-01

    Previous studies have noted a high (41%) prevalence and poor discharge summary communication of pending laboratory (lab) tests at the time of hospital discharge for general medical patients. However, the prevalence and communication of pending labs within a high-risk population, specifically those patients discharged to sub-acute care (i.e., skilled nursing, rehabilitation, long-term care), remains unknown. To determine the prevalence and nature of lab tests pending at hospital discharge and their inclusion within hospital discharge summaries, for common sub-acute care populations. Retrospective cohort study. Stroke, hip fracture, and cancer patients discharged from a single large academic medical center to sub-acute care, 2003-2005 (N = 564) Pending lab tests were abstracted from the laboratory information system (LIS) and from each patient's discharge summary, then grouped into 14 categories and compared. Microbiology tests were sub-divided by culture type and number of days pending prior to discharge. Of sub-acute care patients, 32% (181/564) were discharged with pending lab tests per the LIS; however, only 11% (20/181) of discharge summaries documented these. Patients most often left the hospital with pending microbiology tests (83% [150/181]), particularly blood and urine cultures, and reference lab tests (17% [30/181]). However, 82% (61/74) of patients' pending urine cultures did not have 24-hour preliminary results, and 19% (13/70) of patients' pending blood cultures did not have 48-hour preliminary results available at the time of hospital discharge. Approximately one-third of the sub-acute care patients in this study had labs pending at discharge, but few were documented within hospital discharge summaries. Even after considering the availability of preliminary microbiology results, these omissions remain common. Future studies should focus on improving the communication of pending lab tests at discharge and evaluating the impact that this improved communication has on patient outcomes.

  17. Neoplastic and nonneoplastic liver lesions induced by dimethylinitrosamine in Japanese Medaka fish

    EPA Science Inventory

    Small fish models are becoming commonplace in the laboratory, and have been used for decades in chemical toxicity and carcinogenicity testing. However, extrapolation of findings from aquatic models to humans is still a concern in risk assessment. Demonstration of common morpholog...

  18. A Mandatory Course in Scientific Writing for Undergraduate Medical Students

    ERIC Educational Resources Information Center

    Roland, Charles G.; Cox, Barbara G.

    1976-01-01

    Describes a course required for Mayo Medical School students that includes a self-instructional test on 15 common writing faults, a minithesis, and a clinical laboratory research project prepared as a paper submissible to a scientific journal and critiqued by professional editors. (JT)

  19. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    NASA Astrophysics Data System (ADS)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  20. Performance indicators for quality in surgical and laboratory services at Muhimbili National Hospital (MNH) in Tanzania.

    PubMed

    Mbembati, Naboth A; Mwangu, Mugwira; Muhondwa, Eustace P Y; Leshabari, Melkizedek M

    2008-04-01

    Muhimbili National Hospital (MNH), a teaching and national referral hospital, is undergoing major reforms to improve the quality of health care. We performed a retrospective descriptive study using a set of performance indicators for the surgical and laboratory services of MNH in years 2001 and 2002, to help monitor and evaluate the impact of reforms on the quality of health care during and after the reform process. Hospital records were reviewed and information recorded for planned and postponed operations, laboratory equipment, reagents, laboratory tests and quality assurance programmes. In the year 2001 a total of 4332 non-emergency operations were planned, 3313 operations were performed and 1019 (23.5%) operations were postponed. In the year 2002, 4301 non-emergency operations were planned, 3046 were performed and 1255 (29%) were postponed. The most common reasons for operation postponement were "time-barred", interference by emergency operations, no show of patients and inoperable anaesthetic machines. Equipment problems and supply and staff shortages together accounted for one quarter of postponements. In the laboratory, a lack of equipment prevented some tests, but quality assurance was performed for most tests. Current surgical services at MNH are inadequate; operating theatres require modern, functioning equipment and adequate supplies of consumables to provide satisfactory care.

  1. Clinical Variant Classification: A Comparison of Public Databases and a Commercial Testing Laboratory.

    PubMed

    Gradishar, William; Johnson, KariAnne; Brown, Krystal; Mundt, Erin; Manley, Susan

    2017-07-01

    There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, the well-documented limitations of these databases call into question how often clinicians will encounter discordant variant classifications that may introduce uncertainty into patient management. Here, we evaluate discordance in BRCA1 and BRCA2 variant classifications between a single commercial testing laboratory and a public database commonly consulted in clinical practice. BRCA1 and BRCA2 variant classifications were obtained from ClinVar and compared with the classifications from a reference laboratory. Full concordance and discordance were determined for variants whose ClinVar entries were of the same pathogenicity (pathogenic, benign, or uncertain). Variants with conflicting ClinVar classifications were considered partially concordant if ≥1 of the listed classifications agreed with the reference laboratory classification. Four thousand two hundred and fifty unique BRCA1 and BRCA2 variants were available for analysis. Overall, 73.2% of classifications were fully concordant and 12.3% were partially concordant. The remaining 14.5% of variants had discordant classifications, most of which had a definitive classification (pathogenic or benign) from the reference laboratory compared with an uncertain classification in ClinVar (14.0%). Here, we show that discrepant classifications between a public database and single reference laboratory potentially account for 26.7% of variants in BRCA1 and BRCA2 . The time and expertise required of clinicians to research these discordant classifications call into question the practicality of checking all test results against a database and suggest that discordant classifications should be interpreted with these limitations in mind. With the increasing use of clinical genetic testing for hereditary cancer risk, accurate variant classification is vital to ensuring appropriate medical management. There is a growing move to consult public databases following receipt of a genetic test result from a clinical laboratory; however, we show that up to 26.7% of variants in BRCA1 and BRCA2 have discordant classifications between ClinVar and a reference laboratory. The findings presented in this paper serve as a note of caution regarding the utility of database consultation. © AlphaMed Press 2017.

  2. [Costs and prices of laboratory services].

    PubMed

    Magid, E; Bartels, P D; Brandslund, I; Christensen, M S; Fahrenkrug, J; Hørder, M; Olsen, H; Pedersen, K O; Riber, E

    1991-09-23

    Cost accounting is performed in private and public laboratories. Guidelines for these activities are required and with this objective in mind, the Board of the Danish Society of Clinical Chemistry commissioned a working group to produce a position paper which is presented now in this report. The report discusses the objectives, the principles and the general requirements for cost accounting. The significance of information on costs for the clinicians' rational use of the laboratory is also illustrated. The working group points out that prerequisites for lucid and appropriate costing guidelines are clarification of which purposes information on costs are meant to serve, identification of the relevant cost centers and quality assurance of laboratory services to a defined extent. It is common practice to express laboratory costs as costs per test. The report advocates calculation of the cost per patient contact, i.e. the overall costs for laboratory service in a given investigative situation.

  3. The impact of insecticides to local honey bee colony Apis cerana indica in laboratory condition

    NASA Astrophysics Data System (ADS)

    Putra, Ramadhani E.; Permana, Agus D.; Nuriyah, Syayidah

    2014-03-01

    Heavy use of insecticides considered as one of common practice at local farming systems. Even though many Indonesian researchers had stated the possible detrimental effect of insecticide on agriculture environment and biodiversity, researches on this subject had been neglected. Therefore, our purpose in this research is observing the impact of insecticides usage by farmer to non target organisme like local honey bee (Apis cerana indica), which commonly kept in area near agriculture system. This research consisted of field observations out at Ciburial, Dago Pakar, Bandung and laboratory tests at School of Life Sciences and Technology, Institut Teknologi Bandung. The field observations recorded visited agriculture corps and types of pollen carried by bees to the nest while laboratory test recorderd the effect of common insecticide to mortality and behavior of honey bees. Three types of insecticides used in this research were insecticides A with active agent Chlorantraniliprol 50 g/l, insecticide B with active agent Profenofos 500 g/l, and insecticides C with active agent Chlorantraniliprol 100 g/l and λ-cyhalotrin 50g/l. The results show that during one week visit, wild flower, Wedelia montana, visited by most honey bees with average visit 60 honey bees followed by corn, Zea mays, with 21 honey bees. The most pollen carried by foragers was Wedelia montana, Calliandra callothyrsus, and Zea mays. Preference test show that honeybees tend move to flowers without insecticides as the preference to insecticides A was 12.5%, insecticides B was 0%, and insecticides was C 4.2%. Mortality test showed that insecticides A has LD50 value 0.01 μg/μl, insecticide B 0.31 μg/μl, and insecticides C 0.09 μg/μl which much lower than suggested dosage recommended by insecticides producer. This research conclude that the use of insecticide could lower the pollination service provide by honey bee due to low visitation rate to flowers and mortality of foraging bees.

  4. Hospital-based Clostridium difficile infection surveillance reveals high proportions of PCR ribotypes 027 and 176 in different areas of Poland, 2011 to 2013.

    PubMed

    Pituch, Hanna; Obuch-Woszczatyński, Piotr; Lachowicz, Dominika; Wultańska, Dorota; Karpiński, Paweł; Młynarczyk, Grażyna; van Dorp, Sofie M; Kuijper, Ed J

    2015-01-01

    As part of the European Clostridium difficile infections (CDI) surveillance Network (ECDIS-Net), which aims to build capacity for CDI surveillance in Europe, we constructed a new network of hospital-based laboratories in Poland. We performed a survey in 13 randomly selected hospital-laboratories in different sites of the country to determine their annual CDI incidence rates from 2011 to 2013. Information on C. difficile laboratory diagnostic testing and indications for testing was also collected. Moreover, for 2012 and 2013 respectively, participating hospital-laboratories sent all consecutive isolates from CDI patients between February and March to the Anaerobe Laboratory in Warsaw for further molecular characterisation, including the detection of toxin-encoding genes and polymerase chain reaction (PCR)-ribotyping. Within the network, the mean annual hospital CDI incidence rates were 6.1, 8.6 and 9.6 CDI per 10,000 patient-days in 2011, 2012, and 2013 respectively. Six of the 13 laboratories tested specimens only on the request of a physician, five tested samples of antibiotic-associated diarrhoea or samples from patients who developed diarrhoea more than two days after admission (nosocomial diarrhoea), while two tested all submitted diarrhoeal faecal samples. Most laboratories (9/13) used tests to detect glutamate dehydrogenase and toxin A/B either separately or in combination. In the two periods of molecular surveillance, a total of 166 strains were characterised. Of these, 159 were toxigenic and the majority belonged to two PCR-ribotypes: 027 (n=99; 62%) and the closely related ribotype 176 (n=22; 14%). The annual frequency of PCR-ribotype 027 was not significantly different during the surveillance periods (62.9% in 2012; 61.8% in 2013). Our results indicate that CDIs caused by PCR-ribotype 027 predominate in Polish hospitals participating in the surveillance, with the closely related 176 ribotype being the second most common agent of infection.

  5. Diagnosis of vulvovaginitis: comparison of clinical and microbiological diagnosis.

    PubMed

    Esim Buyukbayrak, Esra; Kars, Bulent; Karsidag, Ayse Yasemin Karageyim; Karadeniz, Bernan Ilkay; Kaymaz, Ozge; Gencer, Serap; Pirimoglu, Zehra Meltem; Unal, Orhan; Turan, Mehmet Cem

    2010-11-01

    The purpose of the present study was to compare the current diagnostic clinical and laboratory approaches to women with vulvovaginal discharge complaint. The secondary outcomes were to determine the prevalence of infections in our setting and to look for the relation between vulvovaginal infections and predisposing factors if present. Premenopausal women applying to our gynecology outpatient clinic with vaginal discharge complaint were enrolled prospectively into the study. Each patient evaluated clinically with direct observation of vaginal secretions, wet mount examination, whiff test, vaginal pH testing and chlamydia rapid antigen test. Each patient also evaluated microbiologically with vaginal discharge culture and gram staining. Clinical diagnosis was compared with the microbiological diagnosis (the gold standard). Diagnostic accuracy was measured with sensitivity, specificity, positive (ppv) and negative predictive values (npv). 460 patients were included in the study. 89.8% of patients received a clinical diagnosis whereas only 36% of them had microbiological diagnosis. The sensitivity, specificity, ppv, npv of clinical diagnosis over microbiological culture results were 95, 13, 38, 82%, respectively. The most commonly encountered microorganisms by culture were Candida species (17.4%) and Gardnerella vaginalis (10.2%). Clinically, the most commonly made diagnoses were mixed infection (34.1%), bacterial vaginosis (32.4%) and fungal infection (14.1%). Symptoms did not predict laboratory results. Predisposing factors (DM, vaginal douching practice, presence of IUD and usage of oral contraceptive pills) were not found to be statistically important influencing factors for vaginal infections. Clinical diagnosis based on combining symptoms with office-based testing improves diagnostic accuracy but is insufficient. The most effective approach also incorporates laboratory testing as an adjunct when a diagnosis is in question or treatment is failing.

  6. Knowledge and Practices of Toxoplasmosis among Clinical Laboratory Professionals: A Cross-Sectional Study in Durango, Mexico

    PubMed Central

    Sánchez-Anguiano, Luis Francisco; Berumen-Segovia, Luis Omar; Hernández-Tinoco, Jesús; Rico-Almochantaf, Yazmin del Rosario; Cisneros-Camacho, Alfredo; Cisneros-Martínez, Jorge Arturo

    2017-01-01

    Background: The aim of this study was to determine the level of knowledge and practices about toxoplasmosis in a sample of clinical laboratory professionals in Mexico. Methods: 192 clinical laboratory professionals were surveyed. They were asked about (1) Toxoplasma gondii; (2) clinical manifestations, diagnosis, treatment, and epidemiology of toxoplasmosis; and (3) their practices with respect to toxoplasmosis. Results: The range of animals infected by T. gondii was known by 44.8% of participants. Clinical aspects of toxoplasmosis were known by up to 44.3% of subjects. Correct answers about the interpretation of serological markers of T. gondii infection were provided by up to 32.8% of participants. A minority (32.2%) of participants knew about a high number of false positive results of anti-T. gondii IgM antibody tests. Most participants (90.1%) did not know what the anti-T. gondii IgG avidity test was. Up to 55.7% of participants provided incorrect answers about the interpretation of serology tests for the treatment of pregnant women. Common routes of T. gondii infection were known by <15% of participants. Most (84.4%) participants had not performed tests for detection T. gondii infection. Conclusions: Results indicate incomplete knowledge of T. gondii infection and toxoplasmosis and a limited practice of laboratory tests among the professionals surveyed. PMID:29156547

  7. Translating Research on Myoelectric Control into Clinics-Are the Performance Assessment Methods Adequate?

    PubMed

    Vujaklija, Ivan; Roche, Aidan D; Hasenoehrl, Timothy; Sturma, Agnes; Amsuess, Sebastian; Farina, Dario; Aszmann, Oskar C

    2017-01-01

    Missing an upper limb dramatically impairs daily-life activities. Efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective article, we suggest that one relevant factor determining the relatively small clinical impact of myocontrol algorithms for upper limb prostheses is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively support this argument with representative data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reaching relatively high classification accuracy offline, their clinical scores varied greatly and were not strongly predicted by classification accuracy. We therefore support the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field.

  8. Clinical and laboratory findings of rhabdomyolysis in opioid overdose patients in the intensive care unit of a poisoning center in 2014 in Iran

    PubMed Central

    Babak, Khoshideh; Mohammad, Arefi; Mazaher, Ghorbani; Fatemeh, Taghizadeh

    2017-01-01

    OBJECTIVES The aim of this study was to investigate the clinical and demographic characteristics and some laboratory findings of hospitalized patients with acute opioid toxicity and rhabdomyolysis. METHODS This cross-sectional study investigated 354 patients hospitalized at Baharloo Hospital in Tehran in 2014 with acute illicit drug toxicity. Data were collected using an investigator-made checklist. The collected data (such as mortality rate, demographic data, and renal function tests, as well as serum biochemical findings) were analyzed by descriptive statistics and the chi-square test. RESULTS A total of 354 patients were admitted to the hospital in 2014 with acute illicit drug toxicity, including 291 males and 63 females. The total number of patients with rhabdomyolysis was 76 (21.5% of the total), of whom 69 (90.8%) were male and 7 (9.2%) were female. Most cases of rhabdomyolysis were associated with methadone abuse, followed by opium abuse. Rhabdomyolysis was most common in those 20-29 and 30-39 years old, with methadone and opium the most commonly abused illicit drugs. The mean blood urea level was 3.8±1.0 mg/dL, and the mean serum potassium and sodium levels were 3.8±0.3 mg/dL and 140.4±4.0 mg/dL, respectively. Five patients, all of whom were male, passed away due to severe renal failure (6.5%). CONCLUSIONS Toxicity caused by opioids is associated with clinical complications and laboratory disorders, such as electrolyte disorders, which can lead to lethal or life-threatening results in some cases. Abnormal laboratory test findings should be identified in patients with opioid toxicity in order to initiate efficient treatment. PMID:29121712

  9. Clinical and laboratory findings of rhabdomyolysis in opioid overdose patients in the intensive care unit of a poisoning center in 2014 in Iran.

    PubMed

    Babak, Khoshideh; Mohammad, Arefi; Mazaher, Ghorbani; Samaneh, Akbarpour; Fatemeh, Taghizadeh

    2017-01-01

    The aim of this study was to investigate the clinical and demographic characteristics and some laboratory findings of hospitalized patients with acute opioid toxicity and rhabdomyolysis. This cross-sectional study investigated 354 patients hospitalized at Baharloo Hospital in Tehran in 2014 with acute illicit drug toxicity. Data were collected using an investigator-made checklist. The collected data (such as mortality rate, demographic data, and renal function tests, as well as serum biochemical findings) were analyzed by descriptive statistics and the chi-square test. A total of 354 patients were admitted to the hospital in 2014 with acute illicit drug toxicity, including 291 males and 63 females. The total number of patients with rhabdomyolysis was 76 (21.5% of the total), of whom 69 (90.8%) were male and 7 (9.2%) were female. Most cases of rhabdomyolysis were associated with methadone abuse, followed by opium abuse. Rhabdomyolysis was most common in those 20-29 and 30-39 years old, with methadone and opium the most commonly abused illicit drugs. The mean blood urea level was 3.8±1.0 mg/dL, and the mean serum potassium and sodium levels were 3.8±0.3 mg/dL and 140.4±4.0 mg/dL, respectively. Five patients, all of whom were male, passed away due to severe renal failure (6.5%). Toxicity caused by opioids is associated with clinical complications and laboratory disorders, such as electrolyte disorders, which can lead to lethal or life-threatening results in some cases. Abnormal laboratory test findings should be identified in patients with opioid toxicity in order to initiate efficient treatment.

  10. Objective vestibular testing of children with dizziness and balance complaints following sports-related concussions.

    PubMed

    Zhou, Guangwei; Brodsky, Jacob R

    2015-06-01

    To conduct objective assessment of children with balance and vestibular complaints following sports-related concussions and identify the underlying deficits by analyzing laboratory test outcomes. Case series with chart review. Pediatric tertiary care facility. Medical records were reviewed of 42 pediatric patients with balance and/or vestibular complaints following sports-related concussions who underwent comprehensive laboratory testing on their balance and vestibular function. Patients' characteristics were summarized and results analyzed. More than 90% of the children with protracted dizziness or imbalance following sports-related concussion had at least 1 abnormal finding from the comprehensive balance and vestibular evaluation. The most frequent deficit was found in dynamic visual acuity test, followed by Sensory Organization Test and rotational test. Patient's balance problem associated with concussion seemed to be primarily instigated by vestibular dysfunction. Furthermore, semicircular canal dysfunction was involved more often than dysfunction of otolith organs. Yet, <10% of the children experienced a hearing loss following sports-related concussion. Vestibular impairment is common among children with protracted dizziness or imbalance following sports-related concussion. Our study demonstrated that proper and thorough evaluation is imperative to identify these underlying deficits and laboratory tests were helpful in the diagnosis and recommendation of following rehabilitations. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  11. Impact of introducing near patient testing for standard investigations in general practice.

    PubMed Central

    Rink, E; Hilton, S; Szczepura, A; Fletcher, J; Sibbald, B; Davies, C; Freeling, P; Stilwell, J

    1993-01-01

    OBJECTIVE--To assess the clinical and economic impact of surgery based near patient testing in general practice for six commonly used biochemical and bacteriological tests. DESIGN--After four months' monitoring, equipment for two bacteriological and four biochemical tests was introduced without cost into 12 practices using a crossover design. Structured request forms were used to monitor laboratory investigations. SETTING--12 general practices in west midlands and south west Thames with list sizes above 9000. MAIN OUTCOME MEASURES--Investigation rates per 1000 consultations. Changes from baseline rates. Reasons for requesting investigations and provisional diagnoses. Cost per test and sensitivity of costs to rate of use. RESULTS--Investigation rates for the six tests rose by 16.5% (from 78.6/1000 consultations to 91.6/1000) when equipment was available in the surgery and reverted to baseline rates when it was withdrawn. The average weekly number of tests when equipment was available ranged from 0.5 to 10.5 (mean 9.0). Cholesterol tests were used as an addition to laboratory testing, usually for screening. Midstream urine analysis was often done in the surgery instead of in the laboratory, although 30% of samples were tested by both methods. Doctors' reasons for investigation and conditions tested were largely unaffected by availability of surgery tests. Costs for surgery tests were higher for all tests except midstream urine. CONCLUSIONS--Availability of surgery based testing increased the number of tests performed. It was cost effective only for midstream urine analysis. PMID:8219952

  12. Food-specific serum IgE and IgG reactivity in dogs with and without skin disease: lack of correlation between laboratories.

    PubMed

    Hardy, Jonathan I; Hendricks, Anke; Loeffler, Anette; Chang, Yu-Mei; Verheyen, Kristien L; Garden, Oliver A; Bond, Ross

    2014-10-01

    Despite conflicting data on their utility and no reports on interlaboratory reproducibility, serum food-specific antibodies are commonly assayed in first-opinion canine practice. To determine both the variability of test results between two laboratories and the frequencies and magnitudes of food reactivity in dogs of different disease status. Sera were obtained from eight dogs with cutaneous adverse food reaction (Group A), 22 with nonfood-induced atopic dermatitis (Group B), 30 with an allergic/inflammatory phenotype (Group C), 12 with miscellaneous skin diseases (Group D) and nine healthy dogs (Group E). Paired sera were submitted to two laboratories (A and B) for assays of food-specific IgE and IgG antibodies. Numbers of positive IgE and IgG tests determined by each laboratory in Groups A, B, D and E were comparable (Group C not included). Significant differences in the magnitude of IgE reactivity between groups for each allergen were seen only for lamb (Laboratory A, P = 0.003); lamb reactivity in Group D exceeded Group E (P = 0.004) but was comparable between all other groups. Agreement (kappa statistic) between the two laboratories' tests was 'moderate' for one antigen (potato IgE), 'fair' for four (corn IgE, rice IgE and IgG and soya bean IgG), 'slight' for eight (six IgE and two IgG) and 'less than chance' for the remaining six antigens (three IgE and three IgG). These laboratories' tests appear to have dubious predictive clinical utility because they neither correlate nor distinguish between dogs of different disease status. © 2014 ESVD and ACVD.

  13. The role of postictal laboratory blood analyses in the diagnosis and prognosis of seizures.

    PubMed

    Nass, Robert D; Sassen, Robert; Elger, Christian E; Surges, Rainer

    2017-04-01

    Epileptic seizures (ES) lead to alterations in the blood laboratory values and reflect changes in different organ systems. Here, we review the diagnostic and prognostic value of various blood laboratory values within the context of epilepsy. Narrative review and literature search on PubMed using the term, "seizure" and various laboratory values. Laboratory markers can help clinicians determine whether an unwitnessed event was more likely to be epileptic or non-epileptic. Prolactin testing helps differentiate ES from psychogenic non-epileptic seizures (PNES) in adults and adolescents, and is associated with high specificity and moderate sensitivity. Elevations in the creatine kinase (CK) levels are common after generalized tonic-clonic seizures (GTCS) and display high specificity and moderate sensitivity. Metabolic markers such as ammonia and lactate may have diagnostic potential for postictal blood tests. Analyzing blood postictally is important for identifying the cause of the symptomatic seizures due to endocrine, metabolic, toxic or infectious etiologies. Finally, laboratory analyses are used for identifying patients who are at risk for developing rare, threatening complications such as rhabdomyolysis, acute renal failure (ARF) or cardiomyopathy. Presently, no postictal laboratory values can definitively prove or rule out the diagnosis of an epileptic seizure. For seizures with unknown causes, simple blood tests can be a valuable aid for quickly defining the etiology, particularly with certain metabolic and toxic encephalopathies. For this reason, CK, electrolytes, creatinine, liver and renal function tests should be measured on at least one occasion. Further research is needed in order to identify new biomarkers that improve the diagnosis and prognosis of seizures and seizure-related complications. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  14. Mitochondrial Disorders of DNA Polymerase γ Dysfunction

    PubMed Central

    Zhang, Linsheng; Chan, Sherine S. L.; Wolff, Daynna J.

    2011-01-01

    Context Primary mitochondrial dysfunction is one of the most common causes of inherited disorders predominantly involving the neuromuscular system. Advances in the molecular study of mitochondrial DNA have changed our vision and our approach to primary mitochondrial disorders. Many of the mitochondrial disorders are caused by mutations in nuclear genes and are inherited in an autosomal recessive pattern. Among the autosomal inherited mitochondrial disorders, those related to DNA polymerase γ dysfunction are the most common and the best studied. Understanding the molecular mechanisms and being familiar with the recent advances in laboratory diagnosis of this group of mitochondrial disorders are essential for pathologists to interpret abnormal histopathology and laboratory results and to suggest further studies for a definitive diagnosis. Objectives To help pathologists better understand the common clinical syndromes originating from mutations in DNA polymerase γ and its associated proteins and use the stepwise approach of clinical, laboratory, and pathologic diagnosis of these syndromes. Data Sources Review of pertinent published literature and relevant Internet databases. Conclusions Mitochondrial disorders are now better recognized with the development of molecular tests for clinical diagnosis. A cooperative effort among primary physicians, diagnostic pathologists, geneticists, and molecular biologists with expertise in mitochondrial disorders is required to reach a definitive diagnosis. PMID:21732785

  15. Comparison of clinical characteristics and laboratory findings of malaria, dengue, and enteric fever in returning travelers: 8-year experience at a referral center in Tokyo, Japan.

    PubMed

    Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio

    2015-07-01

    Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels < 10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms.

  16. Polymylagia rheumatica: common disease, elusive diagnosis.

    PubMed

    Mager, Diana R

    2015-03-01

    Polymyalgia rheumatica (PMR) is a common inflammatory rheumatic disease with little known about its etiology or incidence. Frequently found in older adult women, this disease can be debilitating, painful, and dangerous. Diagnosing PMR can be elusive due to lack of specific laboratory tests, and treatment with use of long-term glucocorticoids can be difficult due to side effects. The following article describes the pathophysiology, diagnosis, signs and symptoms, and treatment of PMR, as well as implications for home healthcare.

  17. Aircraft Power-Plant Instruments

    NASA Technical Reports Server (NTRS)

    Sontag, Harcourt; Brombacher, W G

    1934-01-01

    This report supersedes NACA-TR-129 which is now obsolete. Aircraft power-plant instruments include tachometers, engine thermometers, pressure gages, fuel-quantity gages, fuel flow meters and indicators, and manifold pressure gages. The report includes a description of the commonly used types and some others, the underlying principle utilized in the design, and some design data. The inherent errors of the instrument, the methods of making laboratory tests, descriptions of the test apparatus, and data in considerable detail in the performance of commonly used instruments are presented. Standard instruments and, in cases where it appears to be of interest, those used as secondary standards are described. A bibliography of important articles is included.

  18. [The external evaluation of study quality: the role in maintaining the reliability of laboratory information].

    PubMed

    Men'shikov, V V

    2013-08-01

    The external evaluation of quality of clinical laboratory examinations was gradually introduced in USSR medical laboratories since 1970s. In Russia, in the middle of 1990 a unified all-national system of external evaluation quality was organized known as the Federal center of external evaluation of quality at the basis of laboratory of the state research center of preventive medicine. The main positions of policy in this area were neatly formulated in the guidance documents of ministry of Health. Nowadays, the center of external evaluation of quality proposes 100 and more types of control studies and permanently extends their specter starting from interests of different disciplines of clinical medicine. The consistent participation of laboratories in the cycles of external evaluation of quality intrinsically promotes improvement of indicators of properness and precision of analysis results and increases reliability of laboratory information. However, a significant percentage of laboratories does not participate at all in external evaluation of quality or takes part in control process irregularly and in limited number of tests. The managers of a number of medical organizations disregard the application of the proposed possibilities to increase reliability of laboratory information and limit financing of studies in the field of quality control. The article proposes to adopt the national standard on the basis of ISO 17043 "Evaluation of compliance. The common requirements of professional competence testing".

  19. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2015-10-01

    fatal disease progression, or in the cases of over-treatment, unnecessary physical and emotional trauma.4 ELISA, the most common immunoassay for...laboratory to discover new biomarkers that meet these requirements within serum so that a simple blood test can be implemented. We are also working to...microspheres and tested first on standard samples. Assay performance characteristics will be determined to ascertain that they will address

  20. Occupational asthma due to turpentine in art painter--case report.

    PubMed

    Dudek, Wojciech; Wittczak, Tomasz; Swierczyńska-Machura, Dominika; Walusiak-Skorupa, Jolanta; Pałczyński, Cezary

    2009-01-01

    Turpentine is a fluid obtained by distillation of wood resins containing mixture of terpens. It can act as an irritant and sensitiser. Most common health problem among workers exposed to turpentine is contact dermatitis. Little is know about turpentine to cause type I hypersensitivity reaction. We present a case of a 27-year old art painter using turpentine as a thinner for oil-based paints. She developed asthmatic reactions after 5 years of working with turpentine. A number of clinical procedures were performed, including clinical examination, routine laboratory tests, total serum IgE, skin prick tests to common aeroallergens, metal salts, oil-based paints and balsamic turpentine, resting spirometry test, histamine challenge, and a single-blind, placebo-controlled specific inhalation challenge with balsamic turpentine. Clinical findings and laboratory test results were normal but a significant bronchial hyperreactivity was found. During the specific challenge, dyspnoea and decreased forced expiratory volume (FEV1) were observed in late phase of asthmatic reaction. An increased proportion of eosinophils in induced sputum could also be noted 24 h after the challenge. Positive clinical response to the specific challenge as well as the morphological changes found in induced sputum served as the basis for diagnosing occupational asthma. To our knowledge, this is the first well-documented case of turpentine-induced occupational asthma.

  1. A Method for Evaluating the Efficacy of Antifouling Paints Using Mytilus galloprovincialis in the Laboratory in a Flow-Through System

    PubMed Central

    Satuito, Cyril Glenn Perez; Katsuyama, Ichiro; Ando, Hirotomo; Seki, Yasuyuki; Senda, Tetsuya

    2016-01-01

    A laboratory test with a flow-through system was designed and its applicability for testing antifouling paints of varying efficacies was investigated. Six different formulations of antifouling paints were prepared to have increasing contents (0 to 40 wt.%) of Cu2O, which is the most commonly used antifouling substance, and each formulation of paint was coated on just one surface of every test plate. The test plates were aged for 45 days by rotating them at a speed of 10 knots inside a cylinder drum. A behavioral test was then conducted using five mussels (Mytilus galloprovincialis) that were pasted onto the coated surface of each aged test plate. The number of the byssus threads produced by each mussel generally decreased with increasing Cu2O content of the paint. The newly designed method was considered valid owing to the high consistency of its results with observations from the field experiment. PMID:27959916

  2. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project "Laboratory Errors and Patient Safety".

    PubMed

    Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario

    2011-05-01

    The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.

  3. Isolation and Molecular Detection of Gram Negative Bacteria Causing Urinary Tract Infection in Patients Referred to Shahrekord Hospitals, Iran.

    PubMed

    Tajbakhsh, Elahe; Tajbakhsh, Sara; Khamesipour, Faham

    2015-05-01

    Urinary Tract Infections (UTI), and their complications, cause serious health problems, which affect millions of people every year. Infections of the urinary tract are the second most common type of infection in the body and approximately 20% of women are especially prone to UTIs for reasons not yet well understood. Urinary Tract Infections in men are not as common as in women yet can be very serious when they do occur. Accurate identification of bacterial isolates is an essential task of the clinical microbiology laboratory. The purpose of this study was to determine the incidence and variety of the causative microbial agents of UTIs in patients who had referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord, Iran. In this cross-sectional study 147 urine samples of patients (urine test results were positive for UTIs) were examined during April to September 2013. A total of 147 urine samples of patients with clinical symptoms of UTI who had been referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord (Iran), were collected and processed immediately for laboratory analysis. Escherichia coli was identified as the most common causative agent of UTIs (51.70% of total isolates in both sexes), followed by Klebsiella pneumoniae (K. Pneumoniae) (16.32%). Frequency of Proteus spp., Acinetobacter spp., Entrobacter spp., Citrobacter spp., Pseudomonas aeruginosa (P. aeruginosa) and Providencia spp. was 10.88%, 6.12%, 5.44%, 4.08%, 3.40% and 2.04%, respectively. Statistical analysis by Fisher exact test showed that there was no significant relationship between the type of bacteria and gender (P > 0.05). Chi square test showed that there was no significant relationship between the type of bacteria and the use of catheter and age group (P > 0.05). However, there was a significant relationship between the type of bacteria and the history of hospitalization (P > 0.05). Our findings implied that a wide range of bacteria could be involved in creating urinary tract infection in patients referred to a medical laboratory of Kashani and Hajar hospital in Shahrekord, Iran. Regardless of age, sex and the use of catheter, a wide range of bacteria could be involved in urinary tract infections.

  4. Evaluation of antimicrobial effect of azadirachtin plant extract (Soluneem (™)) on commonly found root canal pathogenic microorganisms (viz. Enterococcus faecalis) in primary teeth: A microbiological study.

    PubMed

    Shah, Shanal; Venkataraghavan, Karthik; Choudhary, Prashant; Mohammad, Shameer; Trivedi, Krishna; Shah, Shalin G

    2016-01-01

    The aim of this study is to evaluate the antimicrobial activity of Soluneem ™ when used as an irrigating solution along with other commonly used irrigating solution sodium hypochlorite (NaOCl) against Enterococcus faecalis. Microorganism used in this study was E. faecalis (Microbial Type Culture Collection 439). Test substance used was Soluneem ™, which was obtained from Vittal Mallya Scientific Research Foundation (VMSRF), Bengaluru. This study was conducted in a microbiology laboratory (Biocare Research India Pvt., Ltd. Laboratory, Ahmedabad, Gujarat) to evaluate the antimicrobial effect of Soluneem ™ (Azadirachtin) on E. faecalis. Antimicrobial activity testing was performed using the macrobroth dilution method according to the Clinical Laboratory Standards Institute guidelines. All determinations were performed thrice. Minimum bactericidal concentration (MBC) was seen as 2.6% for Soluneem ™ while the same was seen at 0.1% for NaOCl. Independent sample t-test was carried out to compare the MBC of Soluneem ™ and NaOCl, which showed that there was no statistically significant difference between them, i.e., 2.6% Soluneem ™ was as effective as 0.1% NaOCl. Soluneem ™ showed antimicrobial activity against E. faecalis at various concentrations. It was also found that the efficacy of Soluneem ™ at 2.6% concentration and above was relatively similar to that of gold standard irrigating solution (NaOCl) on inhibition of E. faecalis.

  5. Multisite reproducibility of the broth microdilution method for susceptibility testing of Nocardia species.

    PubMed

    Conville, Patricia S; Brown-Elliott, Barbara A; Wallace, Richard J; Witebsky, Frank G; Koziol, Deloris; Hall, Geraldine S; Killian, Scott B; Knapp, Cindy C; Warshauer, David; Van, Tam; Wengenack, Nancy L; Deml, Sharon; Woods, Gail L

    2012-04-01

    Antimicrobial susceptibility testing (AST) of clinical isolates of Nocardia is recommended to detect resistance to commonly used antimicrobial agents; such testing is complicated by difficulties in inoculum preparation and test interpretation. In this study, six laboratories performed repetitive broth microdilution testing on single strains of Nocardia brasiliensis, Nocardia cyriacigeorgica, Nocardia farcinica, Nocardia nova, and Nocardia wallacei. For each isolate, a total of 30 microdilution panels from three different lots were tested at most sites. The goal of the study was to determine the inter- and intralaboratory reproducibility of susceptibility testing of this group of isolates. Acceptable agreement (>90% agreement at ±1 dilution of the MIC mode) was found for amikacin, ciprofloxacin, clarithromycin, and moxifloxacin. After eliminating MIC values from single laboratories whose results showed the greatest deviation from those of the remaining laboratories, acceptable agreement was also found for amoxicillin-clavulanic acid, linezolid, minocycline, and tobramycin. Results showed unsatisfactory reproducibility of broth microdilution testing of ceftriaxone with N. cyriacigeorgica and N. wallacei, tigecycline with N. brasiliensis and N. cyriacigeorgica, and sulfonamides with N. farcinica and N. wallacei. N. nova ATCC BAA-2227 is proposed as a quality control organism for AST of Nocardia sp., and the use of a disk diffusion test for sulfisoxazole is proposed as a check of the adequacy of the inoculum and to confirm sulfonamide MIC results.

  6. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    PubMed

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  7. Creep compliance and percent recovery of Oklahoma certified binder using the multiple stress recovery (MSCR) method.

    DOT National Transportation Integrated Search

    2015-04-01

    A laboratory study was conducted to develop guidelines for the Multiple Stress Creep Recovery : (MSCR) test method for local conditions prevailing in Oklahoma. The study consisted of : commonly used binders in Oklahoma, namely PG 64-22, PG 70-28, and...

  8. Laboratory and field evaluations of non-bituminous hot melt pavement marker adhesive Georgia test deck : two year evaluation (fall 2006 product submissions).

    DOT National Transportation Integrated Search

    2008-10-01

    Purpose: : The purpose of the National Transportation Product Evaluation Program (NTPEP) is to provide a cost-effective method of evaluation for materials of common interest among all participating NTPEP member departments. NTPEP reports allow member...

  9. Method and platform standardization in MRM-based quantitative plasma proteomics.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.

  10. Direct dosing of preweaning rodents in toxicity testing and research: deliberations of an ILSI RSI Expert Working Group.

    PubMed

    Moser, Virginia C; Walls, Isabel; Zoetis, Tracey

    2005-01-01

    Laboratory animal studies designed to assess the effects of exposure of a test substance during postnatal development are commonly utilized in basic research and to evaluate potential hazard to children for chemical and pharmaceutical regulation. Direct dosing, defined here as the administration of a test substance directly to a preweaning mammal, has been identified as a useful tool that can be used in the conduct of such studies for regulatory purposes. The International Life Sciences Institute Risk Science Institute (ILSI RSI) convened an Expert Working Group to develop guidance on the design and implementation of direct dosing regulatory studies on preweaning mammals, which was published as an ILSI monograph in 2003 (Zoetis and Walls, Principles and Practices for Direct Dosing of Pre-Weaning Mammals in Toxicity Testing and Research, Washington, DC: ILSI Press, 2003). A summary of the Working Group conclusions regarding direct dosing studies with laboratory rodents are presented here, although the ILSI monograph also includes rabbits, canines, swine and nonhuman primates. Issues to be considered when designing the protocol include selection of the test species, the route of administration, dose levels, and the timing of dosing. Knowledge of the maturational status of the test species and information on critical windows of development are important in creating a valid study design. Most common routes of administration (e.g., oral, inhalation, injection) are possible with typical laboratory species; however, adjustments may be necessary due to practical considerations. Information on the pharmacokinetic profile in young animals versus adults and in the test species versus humans is very useful for determining dosing parameters. The conduct of the study and the interpretation of the data will be improved by an understanding of confounding factors as well as statistical and biological issues specific for postnatal studies. Ultimately, the success of the study will depend upon careful preparation, including thorough training of the technical staff.

  11. Students' perceptions of laboratory science careers: changing ideas with an education module.

    PubMed

    Haun, Daniel; Leach, Argie; Lawrence, Louann; Jarreau, Patsy

    2005-01-01

    To assess the effectiveness of a Web-based education module in changing students' perceptions of laboratory science careers. Perception was measured with a short examination and then a Web-based exercise was presented. Following the exercise, the test was administered again. Frequency data from the pre-test and post-test were compared for changes in perception. The correlated pre-test/post-test pairs were also examined for opinion changes and these were analyzed for significance. Large parochial high schools in New Orleans, Louisiana. A small team visited the schools during their appointed class times for biology. Study participants were high school biology students in grades 9-10. Two-hundred-forty-five students participated (149 male and 96 female). A Web-based exercise on blood film examination was presented to the students in a classroom setting (www.mclno.org/labpartners/index_03.htm). The exercise contained focused messages about: (1) the numbers of healthcare workers acquiring AIDS from on-the-job exposure and (2) common career paths available to the laboratory science workforce. The shift in perception of: What medical service generates the most diagnostic data. Which professional group performs laboratory tests. The risk of acquiring AIDS while working in the healthcare setting. Interest in a science-related career. How much education is required to work in a science-related field. The intervention significantly shifted perception in all areas measured except that of interest in a science-related career. Many students perceive that the risk of acquiring AIDS while working in the healthcare setting is "high". Web-based presentations and similar partnerships with science teachers can change perceptions that might lead to increased interest in clinical laboratory science careers.

  12. Economic Analysis of Alternative Strategies for Detection of ALK Rearrangements in Non Small Cell Lung Cancer.

    PubMed

    Doshi, Shivang; Ray, David; Stein, Karen; Zhang, Jie; Koduru, Prasad; Fogt, Franz; Wellman, Axel; Wat, Ricky; Mathews, Charles

    2016-01-06

    Identification of alterations in ALK gene and development of ALK-directed therapies have increased the need for accurate and efficient detection methodologies. To date, research has focused on the concordance between the two most commonly used technologies, fluorescent in situ hybridization (FISH) and immunohistochemistry (IHC). However, inter-test concordance reflects only one, albeit important, aspect of the diagnostic process; laboratories, hospitals, and payors must understand the cost and workflow of ALK rearrangement detection strategies. Through literature review combined with interviews of pathologists and laboratory directors in the U.S. and Europe, a cost-impact model was developed that compared four alternative testing strategies-IHC only, FISH only, IHC pre-screen followed by FISH confirmation, and parallel testing by both IHC and FISH. Interviews were focused on costs of reagents, consumables, equipment, and personnel. The resulting model showed that testing by IHC alone cost less ($90.07 in the U.S., $68.69 in Europe) than either independent or parallel testing by both FISH and IHC ($441.85 in the U.S. and $279.46 in Europe). The strategies differed in cost of execution, turnaround time, reimbursement, and number of positive results detected, suggesting that laboratories must weigh the costs and the clinical benefit of available ALK testing strategies.

  13. Economic Analysis of Alternative Strategies for Detection of ALK Rearrangements in Non Small Cell Lung Cancer

    PubMed Central

    Doshi, Shivang; Ray, David; Stein, Karen; Zhang, Jie; Koduru, Prasad; Fogt, Franz; Wellman, Axel; Wat, Ricky; Mathews, Charles

    2016-01-01

    Identification of alterations in ALK gene and development of ALK-directed therapies have increased the need for accurate and efficient detection methodologies. To date, research has focused on the concordance between the two most commonly used technologies, fluorescent in situ hybridization (FISH) and immunohistochemistry (IHC). However, inter-test concordance reflects only one, albeit important, aspect of the diagnostic process; laboratories, hospitals, and payors must understand the cost and workflow of ALK rearrangement detection strategies. Through literature review combined with interviews of pathologists and laboratory directors in the U.S. and Europe, a cost-impact model was developed that compared four alternative testing strategies—IHC only, FISH only, IHC pre-screen followed by FISH confirmation, and parallel testing by both IHC and FISH. Interviews were focused on costs of reagents, consumables, equipment, and personnel. The resulting model showed that testing by IHC alone cost less ($90.07 in the U.S., $68.69 in Europe) than either independent or parallel testing by both FISH and IHC ($441.85 in the U.S. and $279.46 in Europe). The strategies differed in cost of execution, turnaround time, reimbursement, and number of positive results detected, suggesting that laboratories must weigh the costs and the clinical benefit of available ALK testing strategies. PMID:26838801

  14. The utility of clinical findings to predict laboratory values in hypertensive disorders of pregnancy.

    PubMed

    So, Jane; Young, Elizabeth; Crnosija, Natalie; Chappelle, Joseph

    2016-04-01

    Preeclampsia is the 2nd leading cause of maternal mortality in the United States. Women with new-onset or worsening hypertension are commonly evaluated for laboratory abnormalities. We aim to investigate whether demographic and/or clinical findings correlate with abnormal laboratory values. A retrospective chart review of women who presented for evaluation of hypertension in pregnancy during 2010. Demographic information, medical history, symptoms, vital signs, and laboratory results were collected. Bivariate analysis was used to investigate associations between predictors and the outcome. Of the 481 women in the sample, 22 were identified as having abnormal laboratory test results (4.6%). Women who reported right upper quadrant pain or tenderness had significantly increased likelihood of having laboratory abnormalities compared to those without the complaint. Only a small percentage of women evaluated were determined to have abnormal laboratory findings, predominantly among women with severe preeclampsia. Right upper quadrant pain or tenderness was positively correlated with laboratory abnormalities. The restriction of laboratory analysis in women with clinical evidence of severe disease may be warranted - a broader study should, however, first be used to confirm our findings.

  15. A frailty index based on laboratory deficits in community-dwelling men predicted their risk of adverse health outcomes.

    PubMed

    Blodgett, Joanna M; Theou, Olga; Howlett, Susan E; Wu, Frederick C W; Rockwood, Kenneth

    2016-07-01

    abnormal laboratory test results accumulate with age and can be common in people with few clinically detectable health deficits. A frailty index (FI) based entirely on common physiological and laboratory tests (FI-Lab) might offer pragmatic and scientific advantages compared with a clinical FI (FI-Clin). to compare the FI-Lab with the FI-Clin and to assess their individual and combined relationships with mortality and other adverse health outcomes. secondary analysis of the eight-centre, longitudinal European Male Ageing Study (EMAS) of community-dwelling men aged 40-79 at baseline. Follow-up assessment occurred 4.4 ± 0.3 (mean ± SD) years later. we constructed a 23-item FI using common laboratory tests, blood pressure and pulse (FI-Lab), compared it with a previously validated 39-item FI using self-report and performance-based measures (FI-Clin) and finally combined both FIs to create a 62-item FI-Combined. Outcomes were all-cause mortality, institutionalisation, doctor visits, medication use, self-reported health, falls and fractures. the mean FI-Lab score was 0.28 ± 0.11, the FI-Clin was 0.13 ± 0.11 and FI-Combined was 0.19 ± 0.09. Age-adjusted models demonstrated that each FI was associated with mortality [HR (CI) FI-Lab: 1.04 (1.03-1.06); FI-Clin: 1.05 (1.04-1.06); FI-Combined: 1.07 (1.06-1.09)], institutionalisation, doctor visits, medication use, self-reported health and falls. Combined in a model with FI-Clin, the FI-Lab remained independently associated with mortality, institutionalisation, doctor visits, medication use and self-reported health. the FI-Lab detected an increased risk of adverse health outcomes alone and in combination with a clinical FI; further evaluation of the feasibility of the FI-Lab as a frailty screening tool within hospital care settings is needed. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMeeking, Gavin R.; Kreidenweis, Sonia M.; Baker, Stephen

    We characterized the gas- and speciated aerosol-phase emissions from the open combustion of 33 different plant species during a series of 255 controlled laboratory burns during the Fire Laboratory at Missoula Experiments (FLAME). The plant species we tested were chosen to improve the existing database for U.S. domestic fuels: laboratory-based emission factors have not previously been reported for many commonly-burned species that are frequently consumed by fires near populated regions and protected scenic areas. The plants we tested included the chaparral species chamise, manzanita, and ceanothus, and species common to the southeastern US (common reed, hickory, kudzu, needlegrass rush, rhododendron,more » cord grass, sawgrass, titi, and wax myrtle). Fire-integrated emission factors for gas-phase CO{sub 2}, CO, CH{sub 4}, C{sub 2-4} hydrocarbons, NH{sub 3}, SO{sub 2}, NO, NO{sub 2}, HNO{sub 3} and particle-phase organic carbon (OC), elemental carbon (EC), SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, Cl{sup -}, Na{sup +}, K{sup +}, and NH{sub 4}{sup +} generally varied with both fuel type and with the fire-integrated modified combustion efficiency (MCE), a measure of the relative importance of flaming- and smoldering-phase combustion to the total emissions during the burn. Chaparral fuels tended to emit less particulate OC per unit mass of dry fuel than did other fuel types, whereas southeastern species had some of the largest observed EF for total fine particulate matter. Our measurements often spanned a larger range of MCE than prior studies, and thus help to improve estimates for individual fuels of the variation of emissions with combustion conditions.« less

  17. Incorporating a collaborative web-based virtual laboratory in an undergraduate bioinformatics course.

    PubMed

    Weisman, David

    2010-01-01

    Face-to-face bioinformatics courses commonly include a weekly, in-person computer lab to facilitate active learning, reinforce conceptual material, and teach practical skills. Similarly, fully-online bioinformatics courses employ hands-on exercises to achieve these outcomes, although students typically perform this work offsite. Combining a face-to-face lecture course with a web-based virtual laboratory presents new opportunities for collaborative learning of the conceptual material, and for fostering peer support of technical bioinformatics questions. To explore this combination, an in-person lecture-only undergraduate bioinformatics course was augmented with a remote web-based laboratory, and tested with a large class. This study hypothesized that the collaborative virtual lab would foster active learning and peer support, and tested this hypothesis by conducting a student survey near the end of the semester. Respondents broadly reported strong benefits from the online laboratory, and strong benefits from peer-provided technical support. In comparison with traditional in-person teaching labs, students preferred the virtual lab by a factor of two. Key aspects of the course architecture and design are described to encourage further experimentation in teaching collaborative online bioinformatics laboratories. Copyright © 2010 International Union of Biochemistry and Molecular Biology, Inc.

  18. Inquiry-based Laboratory Activities on Drugs Analysis for High School Chemistry Learning

    NASA Astrophysics Data System (ADS)

    Rahmawati, I.; Sholichin, H.; Arifin, M.

    2017-09-01

    Laboratory activity is an important part of chemistry learning, but cookbook instructions is still commonly used. However, the activity with that way do not improve students thinking skill, especially students creativity. This study aims to improve high school students creativity through inquiry-based laboratory on drugs analysis activity. Acid-base titration is used to be method for drugs analysis involving a color changing indicator. The following tools were used to assess the activity achievement: creative thinking test on acid base titration, creative attitude and action observation sheets, questionnaire of inquiry-based lab activities, and interviews. The results showed that the inquiry-based laboratory activity improving students creative thinking, creative attitude and creative action. The students reacted positively to this teaching strategy as demonstrated by results from questionnaire responses and interviews. This result is expected to help teachers to overcome the shortcomings in other laboratory learning.

  19. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    PubMed

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  20. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    PubMed Central

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  1. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes

    PubMed Central

    Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.

    2017-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101

  2. What do lollipops and influenza have in common?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekiert, Damian

    2012-06-22

    Human drug trials have begun to test a new way to treat influenza that has the potential to create a universal vaccine. The powerful x-ray beams from the Advanced Light Source at Argonne National Laboratory outside of Chicago enabled scientists to see the structure of the influenza virus clear enough to discover a key commonality among influenza strains. Scientist Damien Ekiert, who won a 2012 award for his work in this discovery, explains why drug manufacturers could capitalize on this.

  3. Petechiae and purpura: the ominous and the not-so-obvious?

    PubMed

    Block, Stan L

    2014-08-01

    Petechiae and purpura are among the most alarming findings a pediatrician will commonly observe in the office. Severity of illness can range from a temper tantrum, to common viral infections, to the most deadly infections and diseases. To avoid many of the pitfalls in diagnosis, practitioners will need to be thorough in history taking, assessing fever and immunization status, and physical examination. In addition, a few simple laboratory tests will usually be needed and possibly a manual differential. Copyright 2014, SLACK Incorporated.

  4. Establishment of quality assurance procedures for aquatic toxicity testing with the nematode Caenorhabditis elegans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeman, M.N.; Marse, T.J.; Williams, P.L.

    1998-12-31

    In this study initial data were generated to develop laboratory control charts for aquatic toxicity testing using the nematode Caenorhabditis elegans. Tests were performed using two reference toxicants: CdCl{sub 2} and CuCl{sub 2}. All tests were performed for 24 h without a food source and of 48 h with a food source in a commonly used nematode aquatic medium. Each test was replicated 6 times with each replicate having 6 wells per concentration with 10 {+-} 1 worms per well. Probit analysis was used to estimate LC{sub 50} values for each test. The data were used to construct a meanmore » ({bar x}) laboratory control chart for each reference toxicant. The coefficient of variation (CV) for three of the four reference toxicant tests was less than 20%, which demonstrates an excellent degree of reproducibility. These CV values are well within suggested standards for determination of organism sensitivity and overall test system credibility. A standardized procedure for performing 24 h and 48 h aquatic toxicity studies with C. elegans is proposed.« less

  5. Experiential learning in control systems laboratories and engineering project management

    NASA Astrophysics Data System (ADS)

    Reck, Rebecca Marie

    Experiential learning is a process by which a student creates knowledge through the insights gained from an experience. Kolb's model of experiential learning is a cycle of four modes: (1) concrete experience, (2) reflective observation, (3) abstract conceptualization, and (4) active experimentation. His model is used in each of the three studies presented in this dissertation. Laboratories are a popular way to apply the experiential learning modes in STEM courses. Laboratory kits allow students to take home laboratory equipment to complete experiments on their own time. Although students like laboratory kits, no previous studies compared student learning outcomes on assignments using laboratory kits with existing laboratory equipment. In this study, we examined the similarities and differences between the experiences of students who used a portable laboratory kit and students who used the traditional equipment. During the 2014- 2015 academic year, we conducted a quasi-experiment to compare students' achievement of learning outcomes and their experiences in the instructional laboratory for an introductory control systems course. Half of the laboratory sections in each semester used the existing equipment, while the other sections used a new kit. We collected both quantitative data and qualitative data. We did not identify any major differences in the student experience based on the equipment they used. Course objectives, like research objectives and product requirements, help provide clarity and direction for faculty and students. Unfortunately, course and laboratory objectives are not always clearly stated. Without a clear set of objectives, it can be hard to design a learning experience and determine whether students are achieving the intended outcomes of the course or laboratory. In this study, I identified a common set of laboratory objectives, concepts, and components of a laboratory apparatus for undergraduate control systems laboratories. During the summer of 2015, a panel of 40 control systems faculty members, from a variety of institutions, completed a multi-round Delphi survey in order to bring them toward consensus on the common aspects of their laboratories. The following winter, 45 additional faculty members and practitioners from the control systems community completed a follow-up survey to gather feedback on the results of the Delphi survey. During the Delphi study, the panelists identified 15 laboratory objectives, 26 concepts, and 15 components that were common in their laboratories. Then in both the Delphi survey and follow-up survey each participant rated the importance of each of these items. While the average ratings differed slightly between the two groups, the order of each set of items was compared with two different tests and the order was found to be similar. Some of the common and important learning objectives include connecting theory to what is implemented and observed in the laboratory, designing controllers, and modeling and simulating systems. The most common component in both groups was Math-Works software. Some of the common concepts include block diagrams, stability, and PID control. Defining common aspects of undergraduate control systems laboratories enables common development, detailed comparisons, and simplified adaptation of equipment and experiments between campuses and programs. Throughout an undergraduate program in engineering, there are multiple opportunities for hands-on laboratory experiences that are related to course content. However, a similarly immersive experience for project management graduate students is harder to incorporate for all students in a course at once. This study explores an experiential learning opportunity for graduate students in engineering management or project management programs. The project management students enroll in a project management course. Undergraduate students interested in working on a project with a real customer enroll in a different projects course. Two students from the project management course function as project managers and lead a team of undergraduate students in the second course through a project. I studied how closely the project management experience in these courses aligns with engineering project management in industry. In the spring of 2015, I enrolled in the project management course at a large Midwestern university. I used analytic autoethnography to compare my experiences in the course with my experiences as a project engineer at a large aerospace company. I found that the experience in the course provided an authentic and comprehensive opportunity to practice most of the skills listed in the Project Management Book of Knowledge (an industry standard) as necessary for project managers. Some components of the course that made it successful: I was the project manager for the whole term, I worked with a real client, and the team defined and delivered the project before the end of the semester.

  6. Pathology consultation on anticoagulation monitoring: factor X-related assays.

    PubMed

    Wool, Geoffrey D; Lu, Chuanyi M

    2013-11-01

    To review various anticoagulation therapies and related laboratory monitoring issues, with a focus on factor X-related chromogenic assays. A case-based approach is used to review pertinent published literatures and product inserts of anticoagulation drugs and to look back on clinical use of factor X-related chromogenic assays. The number of anticoagulants available to clinicians has increased greatly in the past decade. Whether and how these anticoagulants should be monitored are areas of uncertainty for clinicians, which can lead to misuse of laboratory assays and suboptimal patient management. Factor X-related assays are of particular concern because of the similar and often confusing test names. Based on a common clinical case scenario and literature review regarding anticoagulant monitoring, an up-to-date discussion and review of the various factor X-related assays are provided, focusing on the differences in test designs and clinical utilities between the chromogenic anti-Xa and chromogenic factor X activity assays. Anticoagulation therapy and related laboratory monitoring are rapidly evolving areas of clinical practices. A good knowledge of relevant laboratory assays and their clinical applications is necessary to help optimize patient care.

  7. Specialized sperm function tests in varicocele and the future of andrology laboratory.

    PubMed

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele.

  8. A noise control package for vibrating screens1),2)

    PubMed Central

    Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.

    2015-01-01

    Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrens, J.S.

    For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer`s performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy`s needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people usingmore » the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations.« less

  10. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis

    PubMed Central

    2014-01-01

    Background The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. Objectives To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. Data Sources The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. Review Methods Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. Results Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens’ DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960–0.973). Limitations Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. Conclusions Moderate quality evidence showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement. Five observational studies compared 3 point-of-care HbA1c devices with laboratory HbA1c assays, and all reported strong correlation between the 2 tests. PMID:26316922

  11. RAS screening in colorectal cancer: a comprehensive analysis of the results from the UK NEQAS colorectal cancer external quality assurance schemes (2009-2016).

    PubMed

    Richman, Susan D; Fairley, Jennifer; Butler, Rachel; Deans, Zandra C

    2017-12-01

    Evidence strongly indicates that extended RAS testing should be undertaken in mCRC patients, prior to prescribing anti-EGFR therapies. With more laboratories implementing testing, the requirement for External Quality Assurance schemes increases, thus ensuring high standards of molecular analysis. Data was analysed from 15 United Kingdom National External Quality Assessment Service (UK NEQAS) for Molecular Genetics Colorectal cancer external quality assurance (EQA) schemes, delivered between 2009 and 2016. Laboratories were provided annually with nine colorectal tumour samples for genotyping. Information on methodology and extent of testing coverage was requested, and scores given for genotyping, interpretation and clerical accuracy. There has been a sixfold increase in laboratory participation (18 in 2009 to 108 in 2016). For RAS genotyping, fewer laboratories now use Roche cobas®, pyrosequencing and Sanger sequencing, with more moving to next generation sequencing (NGS). NGS is the most commonly employed technology for BRAF and PIK3CA mutation screening. KRAS genotyping errors were seen in ≤10% laboratories, until the 2014-2015 scheme, when there was an increase to 16.7%, corresponding to a large increase in scheme participants. NRAS genotyping errors peaked at 25.6% in the first 2015-2016 scheme but subsequently dropped to below 5%. Interpretation and clerical accuracy scores have been consistently good throughout. Within this EQA scheme, we have observed that the quality of molecular analysis for colorectal cancer has continued to improve, despite changes in the required targets, the volume of testing and the technologies employed. It is reassuring to know that laboratories clearly recognise the importance of participating in EQA schemes.

  12. Multifaceted intervention including education, rounding checklist implementation, cost feedback, and financial incentives reduces inpatient laboratory costs.

    PubMed

    Yarbrough, Peter M; Kukhareva, Polina V; Horton, Devin; Edholm, Karli; Kawamoto, Kensaku

    2016-05-01

    Inappropriate laboratory testing is a contributor to waste in healthcare. To evaluate the impact of a multifaceted laboratory reduction intervention on laboratory costs. A retrospective, controlled, interrupted time series (ITS) study. University of Utah Health Care, a 500-bed academic medical center in Salt Lake City, Utah. All patients 18 years or older admitted to the hospital to a service other than obstetrics, rehabilitation, or psychiatry. Multifaceted quality-improvement initiative in a hospitalist service including education, process change, cost feedback, and financial incentive. Primary outcomes of lab cost per day and per visit. Secondary outcomes of number of basic metabolic panel (BMP), comprehensive metabolic panel (CMP), complete blood count (CBC), and prothrombin time/international normalized ratio tests per day; length of stay (LOS); and 30-day readmissions. A total of 6310 hospitalist patient visits (intervention group) were compared to 25,586 nonhospitalist visits (control group). Among the intervention group, the unadjusted mean cost per day was reduced from $138 before the intervention to $123 after the intervention (P < 0.001), and the unadjusted mean cost per visit decreased from $618 to $558 (P = 0.005). The ITS analysis showed significant reductions in cost per day, cost per visit, and the number of BMP, CMP, and CBC tests per day (P = 0.034, 0.02, <0.001, 0.004, and <0.001). LOS was unchanged and 30-day readmissions decreased in the intervention group. A multifaceted approach to laboratory reduction demonstrated a significant reduction in laboratory cost per day and per visit, as well as common tests per day at a major academic medical center. Journal of Hospital Medicine 2016;11:348-354. © 2016 Society of Hospital Medicine. © 2016 Society of Hospital Medicine.

  13. Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.

    PubMed

    Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi

    2009-12-01

    Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.

  14. DIRECT secure messaging as a common transport layer for reporting structured and unstructured lab results to outpatient providers.

    PubMed

    Sujansky, Walter; Wilson, Tom

    2015-04-01

    This report describes a grant-funded project to explore the use of DIRECT secure messaging for the electronic delivery of laboratory test results to outpatient physicians and electronic health record systems. The project seeks to leverage the inherent attributes of DIRECT secure messaging and electronic provider directories to overcome certain barriers to the delivery of lab test results in the outpatient setting. The described system enables laboratories that generate test results as HL7 messages to deliver these results as structured or unstructured documents attached to DIRECT secure messages. The system automatically analyzes generated HL7 messages and consults an electronic provider directory to determine the appropriate DIRECT address and delivery format for each indicated recipient. The system also enables lab results delivered to providers as structured attachments to be consumed by HL7 interface engines and incorporated into electronic health record systems. Lab results delivered as unstructured attachments may be printed or incorporated into patient records as PDF files. The system receives and logs acknowledgement messages to document the status of each transmitted lab result, and a graphical interface allows searching and review of this logged information. The described system is a fully implemented prototype that has been tested in a laboratory setting. Although this approach is promising, further work is required to pilot test the system in production settings with clinical laboratories and outpatient provider organizations. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Dengue and Other Common Causes of Acute Febrile Illness in Asia: An Active Surveillance Study in Children

    PubMed Central

    Capeding, Maria Rosario; Chua, Mary Noreen; Hadinegoro, Sri Rezeki; Hussain, Ismail I. H. M.; Nallusamy, Revathy; Pitisuttithum, Punnee; Rusmil, Kusnandi; Thisyakorn, Usa; Thomas, Stephen J.; Huu Tran, Ngoc; Wirawan, Dewa Nyoman; Yoon, In-Kyu; Bouckenooghe, Alain; Hutagalung, Yanee; Laot, Thelma; Wartel, Tram Anh

    2013-01-01

    Background Common causes of acute febrile illness in tropical countries have similar symptoms, which often mimic those of dengue. Accurate clinical diagnosis can be difficult without laboratory confirmation and disease burden is generally under-reported. Accurate, population-based, laboratory-confirmed incidence data on dengue and other causes of acute fever in dengue-endemic Asian countries are needed. Methods and principal findings This prospective, multicenter, active fever surveillance, cohort study was conducted in selected centers in Indonesia, Malaysia, Philippines, Thailand and Vietnam to determine the incidence density of acute febrile episodes (≥38°C for ≥2 days) in 1,500 healthy children aged 2–14 years, followed for a mean 237 days. Causes of fever were assessed by testing acute and convalescent sera from febrile participants for dengue, chikungunya, hepatitis A, influenza A, leptospirosis, rickettsia, and Salmonella Typhi. Overall, 289 participants had acute fever, an incidence density of 33.6 per 100 person-years (95% CI: 30.0; 37.8); 57% were IgM-positive for at least one of these diseases. The most common causes of fever by IgM ELISA were chikungunya (in 35.0% of in febrile participants) and S. Typhi (in 29.4%). The overall incidence density of dengue per 100 person-years was 3.4 by nonstructural protein 1 (NS1) antigen positivity (95% CI: 2.4; 4.8) and 7.3 (95% CI: 5.7; 9.2) by serology. Dengue was diagnosed in 11.4% (95% CI: 8.0; 15.7) and 23.9% (95% CI: 19.1; 29.2) of febrile participants by NS1 positivity and serology, respectively. Of the febrile episodes not clinically diagnosed as dengue, 5.3% were dengue-positive by NS1 antigen testing and 16.0% were dengue-positive by serology. Conclusions During the study period, the most common identified causes of pediatric acute febrile illness among the seven tested for were chikungunya, S. Typhi and dengue. Not all dengue cases were clinically diagnosed; laboratory confirmation is essential to refine disease burden estimates. PMID:23936565

  16. Indications for Vitamin B12 Therapy

    PubMed Central

    Delva, M. Dianne; Anderson, J.E.

    1992-01-01

    A retrospective chart audit was undertaken to determine the clinical reasons for vitamin B12 therapy in family practice. Abnormal laboratory tests and symptoms were the most common reasons for initiating therapy. The high proportion of cases with little supporting evidence of B12 deficiency suggests that other factors influence treatment decisions. PMID:20469527

  17. 78 FR 31560 - Medicare Program; Public Meeting in Calendar Year 2013 for New Clinical Laboratory Test Payment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ... announces a public meeting to receive comments and recommendations (including accompanying data on which recommendations are based) from the public on the appropriate basis for establishing payment amounts for new or substantially revised Healthcare Common Procedure Coding System (HCPCS) codes being considered for Medicare...

  18. Systems engineering and integration: Advanced avionics laboratories

    NASA Technical Reports Server (NTRS)

    1990-01-01

    In order to develop the new generation of avionics which will be necessary for upcoming programs such as the Lunar/Mars Initiative, Advanced Launch System, and the National Aerospace Plane, new Advanced Avionics Laboratories are required. To minimize costs and maximize benefits, these laboratories should be capable of supporting multiple avionics development efforts at a single location, and should be of a common design to support and encourage data sharing. Recent technological advances provide the capability of letting the designer or analyst perform simulations and testing in an environment similar to his engineering environment and these features should be incorporated into the new laboratories. Existing and emerging hardware and software standards must be incorporated wherever possible to provide additional cost savings and compatibility. Special care must be taken to design the laboratories such that real-time hardware-in-the-loop performance is not sacrificed in the pursuit of these goals. A special program-independent funding source should be identified for the development of Advanced Avionics Laboratories as resources supporting a wide range of upcoming NASA programs.

  19. Role of the laboratory in the evaluation of suspected drug abuse.

    PubMed

    Gold, M S; Dackis, C A

    1986-01-01

    Despite the high incidence of substance abuse, it remains a common cause of misdiagnosis. In patients who have abused or who are currently abusing drugs, symptoms of a psychiatric illness may be mimicked by either the drug's presence or absence. The laboratory can aid in making a differential diagnosis and eliminating drugs from active consideration as a cause of psychosis, depression, mania, and personality changes. Treatment planning and prevention of serious medical consequences often rest on the accuracy of the admission drug screen. Testing is widely used to assess improvement in substance abuse in both inpatient and outpatient settings. In occupational settings, testing has been used as an early indicator that a problem exists and as a successful prevention tool. The appropriate use of analytic technology in drug abuse testing requires an understanding of available test methodologies. These include drug screens by thin-layer chromatography, comprehensive testing using enzyme immunoassay, and computer-assisted gas chromatography-mass spectrometry (GC-MS). Testing for specific drugs considered likely causes or precipitants of "psychiatric" complaints is available with enzyme assays, radioimmunoassay, or definitive forensic-quality testing using GC-MS.

  20. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  1. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  2. Results of advanced battery technology evaluations for electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1992-10-01

    Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.

  3. Carotenaemia in children is common and benign: most can stay at home.

    PubMed

    McGowan, R; Beattie, J; Galloway, P

    2004-08-01

    We identified children with elevated plasma carotene levels who attended the Royal Hospital for Sick Children, Glasgow, between July 1998 and April 2001 and carried out a retrospective case record review. Thirty-one children were identified (7 boys; 14 girls) with a median age at presentation of 13 months (range 7m- 11yrs). Twenty-seven (87%) children had simple diet-related carotenaemia and were well. In four cases the hypercarotenaemia reflected nutritional problems with associated failure to thrive. In only one case did the family doctor recognise the condition before referral. Many who attended hospital had laboratory confirmation of the benign diagnosis despite a clear dietary origin. Some had repeat laboratory tests to confirm resolution. Diet-related carotenaemia appears common in our community. The condition appears poorly recognised within primary care and hospital investigations may be over-enthusiastic.

  4. Clinical manifestations and laboratory findings of 496 children with brucellosis in Van, Turkey.

    PubMed

    Parlak, Mehmet; Akbayram, Sinan; Doğan, Murat; Tuncer, Oğuz; Bayram, Yasemin; Ceylan, Nesrin; Özlük, Suat; Akbayram, Hatice Tuba; Öner, Abdurrahman

    2015-08-01

    Brucellosis is the most common zoonotic disease worldwide and remains an important human disease especially in developing countries. The aim of the present study was to evaluate clinical manifestations and laboratory findings of childhood brucellosis in Van province of Eastern Turkey. To our knowledge, this is the largest series of childhood brucellosis reported in the literature. In this retrospective study, 496 children with brucellosis were assessed for the clinical manifestations and laboratory findings from July 2009 through December 2013. The diagnosis of brucellosis was based on clinical findings and a standard tube agglutination test (titer ≥ 1:160). Data were analyzed using Minitab version 16. The study included 496 children (boys, 60.5%) with a mean age of 10.0 ± 3.95 years (range, 1-16 years). The most frequent clinical symptoms were arthralgia (46.2%), fever (32.1%), and abdominal pain (17.1%) and the most common clinical signs were peripheral arthritis (10.1%), splenomegaly (2.2%) and hepatomegaly (1.8%). The most contagious seasons were summer and autumn (63.3%). Elevated lactate dehydrogenase and C-reactive protein and erythrocyte sedimentation rate were reported in 63.1%, 58.7%, and 55.2% of the patients, respectively. Anemia (20.4%), thrombocytopenia (15.5%), and leukopenia (12.1%) were the most common hematologic findings. Brucellosis remains a serious public health problem in Turkey. The clinical and laboratory characteristics of childhood brucellosis have been described in order to assist clinicians in diagnosing and monitoring the disease. © 2015 Japan Pediatric Society.

  5. Identification and Quantitation of Sorbitol-Based Nuclear Clarifying Agents Extracted from Common Laboratory and Consumer Plasticware Made of Polypropylene

    PubMed Central

    McDonald, Jeffrey G.; Cummins, Carolyn L.; Barkley, Robert M.; Thompson, Bonne M.; Lincoln, Holly A.

    2009-01-01

    Reported here is the mass spectral identification of sorbitol-based nuclear clarifying agents (NCAs) and the quantitative description of their extractability from common laboratory and household plasticware made of polypropylene. NCAs are frequently added to polypropylene to improve optical clarity, increase performance properties, and aid in the manufacturing process of this plastic. NCA addition makes polypropylene plasticware more aesthetically pleasing to the user and makes the product competitive with other plastic formulations. We show here that several NCAs are readily extracted with either ethanol or water from plastic labware during typical laboratory procedures. Observed levels ranged from a nanogram to micrograms of NCA. NCAs were also detected in extracts from plastic food storage containers; levels ranged from 1to 10 μg in two of the three brands tested. The electron ionization mass spectra for three sorbitol-based nuclear clarifying agents (1,3:2,4-bis-O-(benzylidene)sorbitol, 1,3:2,4-bis-O-(p-methylbenzylidene)sorbitol, 1,3:2,4-bis-O-(3,4-dimethylbenzylidene)sorbitol) are presented for the native and trimethylsilylderivatized compounds together with the collision-induced dissociation mass spectra; gas and liquid chromatographic data are also reported. These NCAs now join other well-known plasticizers such as phthalate esters and bisphenol A as common laboratory contaminants. While the potential toxicity of NCAs in mammalian systems is unknown, the current data provide scientists and consumers the opportunity to make more informed decisions regarding the use of polypropylene plastics. PMID:18533681

  6. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    PubMed

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  7. Heparin-induced thrombocytopenia: reducing misdiagnosis via collaboration between an inpatient anticoagulation pharmacy service and hospital reference laboratory.

    PubMed

    Burnett, Allison E; Bowles, Harmony; Borrego, Matthew E; Montoya, Tiffany N; Garcia, David A; Mahan, Charles

    2016-11-01

    Misdiagnosis of heparin-induced thrombocytopenia (HIT) is common and exposes patients to high-risk therapies and potentially serious adverse events. The primary objective of this study was to evaluate the impact of collaboration between an inpatient pharmacy-driven anticoagulation management service (AMS) and hospital reference laboratory to reduce inappropriate HIT antibody testing via pharmacist intervention and use of the 4T pre-test probability score. Secondary objectives included clinical outcomes and cost-savings realized through reduced laboratory testing and decreased unnecessary treatment of HIT. This was a single center, pre-post, observational study. The hospital reference laboratory contacted the AMS when they received a blood sample for an enzyme-linked immunosorbent HIT antibody (HIT Ab). Trained pharmacists prospectively scored each HIT Ab ordered by using the 4T score with subsequent communication to physicians recommending for or against processing and reporting of lab results. Utilizing retrospective chart review and a database for all patients with a HIT Ab ordered during the study period, we compared the incidence of HIT Ab testing before and after implementation of the pharmacy-driven 4T score intervention. Our intervention significantly reduced the number of inappropriate HIT Ab tests processed (176 vs. 63, p < 0.0001), with no increase in thrombotic or hemorrhagic events. Overall incidence of suspected and confirmed HIT was <3 and <0.005 %, respectively. Overall cost savings were $75,754 (US) or 62 % per patient exposed to heparin between the pre and post intervention groups. Collaboration between inpatient pharmacy AMS and hospital reference laboratories can result in reduction of misdiagnosis of HIT and significant cost savings with similar safety.

  8. Comparison of clinical characteristics and laboratory findings of malaria, dengue, and enteric fever in returning travelers: 8-year experience at a referral center in Tokyo, Japan.

    PubMed

    Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio

    2015-04-01

    Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels <10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Physiological responses to simulated firefighter exercise protocols in varying environments.

    PubMed

    Horn, Gavin P; Kesler, Richard M; Motl, Robert W; Hsiao-Wecksler, Elizabeth T; Klaren, Rachel E; Ensari, Ipek; Petrucci, Matthew N; Fernhall, Bo; Rosengren, Karl S

    2015-01-01

    For decades, research to quantify the effects of firefighting activities and personal protective equipment on physiology and biomechanics has been conducted in a variety of testing environments. It is unknown if these different environments provide similar information and comparable responses. A novel Firefighting Activities Station, which simulates four common fireground tasks, is presented for use with an environmental chamber in a controlled laboratory setting. Nineteen firefighters completed three different exercise protocols following common research practices. Simulated firefighting activities conducted in an environmental chamber or live-fire structures elicited similar physiological responses (max heart rate: 190.1 vs 188.0 bpm, core temperature response: 0.047°C/min vs 0.043°C/min) and accelerometry counts. However, the response to a treadmill protocol commonly used in laboratory settings resulted in significantly lower heart rate (178.4 vs 188.0 bpm), core temperature response (0.037°C/min vs 0.043°C/min) and physical activity counts compared with firefighting activities in the burn building. Practitioner Summary: We introduce a new approach for simulating realistic firefighting activities in a controlled laboratory environment for ergonomics assessment of fire service equipment and personnel. Physiological responses to this proposed protocol more closely replicate those from live-fire activities than a traditional treadmill protocol and are simple to replicate and standardise.

  10. Epidemiology of alcohol and other drug use among motor vehicle crash victims admitted to a trauma center.

    PubMed

    Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J

    2004-09-01

    The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.

  11. Evaluation of the performance and response of the bacharach TLV sniffer and H-Nu photoionization gas analyzer to common hydrocarbon solvents.

    PubMed

    Chelton, C F; Zakraysek, N; Lautner, G M; Confer, R G

    1983-10-01

    Two direct reading instruments, the H-Nu PI 101 photoionization analyzer and the J.W. Bacharach TLV Sniffer, were evaluated under laboratory conditions to determine their performance characteristics when challenged by vapors of common hydrocarbon solvent mixtures. Each instrument was evaluated against the manufacturer's recommended test solvent for rise time, fall time, noise, span drift, zero drift, position sensitivity, battery life, and recharge time. The precision, accuracy, and operating linear range were also determined for the test solvents and some petroleum solvent mixtures which are common refinery products. For these latter mixtures, correction factors are presented which allow for an improved estimate of ambient concentrations when monitoring with each of these instruments. All tests except operating humidity range were performed by challenging each instrument with a known concentration of hydrocarbon generated by evaporating calculated liquid volumes into a static chamber. Humidity tests were performed using a dynamic dilution apparatus generating a fixed concentration of hydrocarbon while relative humidity was varied. Concentrations in both systems were verified by gas injection into gas chromatograph. Each instrument performed well when challenged by manufacturers' recommended test solvents. Humidity was shown to influence each instrument's readings. Also, the instruments were shown to have application as monitors of airborne concentrations of common hydrocarbon solvent mixtures.

  12. Clinical and laboratory differences between Epstein-Barr and cytomegalovirus infectious mononucleosis in children.

    PubMed

    Medović, Rasa; Igrutinović, Zoran; Radojević-Marjanović, Ruzica; Marković, Slavica; Rasković, Zorica; Simović, Aleksandra; Tanasković-Nestorović, Jelena; Radovanović, Marija; VuIetić, Blijana

    2016-01-01

    Infective mononucleosis is most commonly caused by Epstein-Barr virus (EBV), and in smaller percentage by cytomegalovirus (CMV). The aim of this paper was to determine the clinical and laboratory differences between EBV and CMV infectious mononucleosis in children. Cohort retrospective analytical research was conducted. We used data from medical history in six years period and monitored anamnestic data, frequency of inspection and palpation obtained data during physical examination, several laboratory tests, abdomen ultrasonography examination finding and emergence of disease complications. Statistical processing of data has been performed using SPSS 20. Total number of examined children was 137, out of which 85.4% were with EBV and 14.6% with CMV infection. Affected children were most commonly younger than eight years. Boys were affected more often. There was no difference in frequency of high temperature, sore throat, bad breath, and respiratory symptomatology between examined children. Differences were discovered in frequency of stomachaches, eyelid swelling, skin rash and fatigue. Differences were not proven in the frequency of angina, lymphadenopathy and splenohepatomegaly between the groups. Values of transaminases and lactic dehydrogenases significantly decreased after seven days of hospitalization in both groups. In children with EBV, values of transaminases declined faster than in children with CMV. Anemia and bacterial superinfection of pharynx were most common disease complications. Thrombocytopenia was more common in children with CMV infection. Average duration of hospitalization was 6.7 days. In children with CMV abdominal pain, eyelid swelling, skin rash, fatigue and thrombocytopenia were more common. In children with EBV values of transaminases declined significantly faster.

  13. Molecular Methods and Platforms for Infectious Diseases Testing

    PubMed Central

    Emmadi, Rajyasree; Boonyaratanakornkit, Jerry B.; Selvarangan, Rangaraj; Shyamala, Venkatakrishna; Zimmer, Barbara L.; Williams, Laurina; Bryant, Bonita; Schutzbank, Ted; Schoonmaker, Michele M.; Amos Wilson, Jean A.; Hall, Leslie; Pancholi, Preeti; Bernard, Kathryn

    2011-01-01

    The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term. PMID:21871973

  14. High prevalence of sensitization to aeroallergens in children 4 yrs of age or younger with symptoms of allergic disease.

    PubMed

    Baatenburg de Jong, Adriana; Dikkeschei, Lambert D; Brand, Paul L P

    2009-12-01

    The assumption that sensitization to aeroallergens is rare in preschool children is based on population studies in which most subjects have little or no symptoms of atopic disease. We assessed the prevalence of atopic sensitization in children 0 to 4 yr of age presenting with symptoms of allergic disease by reviewing results of all specific immunoglobulin (IgE) tests performed in our hospital laboratory in children 4 yr of age or younger between 1985 and 2003. Tests were ordered by general practitioners or hospital-based pediatricians in children presenting with symptoms of allergic disease. Specific IgE tests to a panel of common food and inhalant allergens were performed in 2946 children; a specific IgE concentration >0.35 kU/l was considered positive. Overall, 505 (17%) tests were positive to aeroallergens: 346 (12%) for house dust mite, 257 (9%) for dog dander, 240 (8%) for cat dander, and 197 (7%) for grass pollen. Positive tests were more common in boys (19.2%) than in girls (14.2%, p < 0.01), irrespective of age. Although sensitization to food allergens was more common in 0-<3 yr olds, aeroallergen and food allergen showed comparable prevalence rates in 3-<5 yr olds. Sensitization to aeroallergens is common in preschool children with symptoms of allergic disease, and more common in boys than in girls. Screening tests for allergy in infants and toddlers should include inhalant allergens.

  15. Swab or biopsy samples for bioburden testing of allograft musculoskeletal tissue?

    PubMed

    Varettas, Kerry

    2014-12-01

    Swab and biopsy samples of allograft musculoskeletal tissue are most commonly collected by tissue banks for bacterial and fungal bioburden testing. An in vitro study was performed using the National Committee for Clinical Laboratory Standards standard 'Quality control of microbiological transport systems' (2003) to validate and evaluate the recovery of six challenge organisms from swab and biopsy samples of allograft musculoskeletal tissue. On average, 8.4 to >100 and 7.2 to >100 % of the inoculum was recovered from swab and biopsy samples respectively. A retrospective review of donor episodes was also performed, consisting of paired swab and biopsy samples received in this laboratory during the period 2001-2012. Samples of allograft femoral heads were collected from living donors during hip operations. From the 3,859 donor episodes received, 21 paired swab and biopsy samples each recovered an isolate, 247 swab samples only and 79 biopsy samples only were culture positive. Low numbers of challenge organisms were recovered from inoculated swab and biopsy samples in the in vitro study and validated their use for bioburden testing of allograft musculoskeletal tissue. Skin commensals were the most common group of organisms isolated during a 12-year retrospective review of paired swab and biopsy samples from living donor allograft femoral heads. Paired swab and biopsy samples are a suitable representative sample of allograft musculoskeletal tissue for bioburden testing.

  16. Using information theory to identify redundancy in common laboratory tests in the intensive care unit.

    PubMed

    Lee, Joon; Maslove, David M

    2015-07-31

    Clinical workflow is infused with large quantities of data, particularly in areas with enhanced monitoring such as the Intensive Care Unit (ICU). Information theory can quantify the expected amounts of total and redundant information contained in a given clinical data type, and as such has the potential to inform clinicians on how to manage the vast volumes of data they are required to analyze in their daily practice. The objective of this proof-of-concept study was to quantify the amounts of redundant information associated with common ICU lab tests. We analyzed the information content of 11 laboratory test results from 29,149 adult ICU admissions in the MIMIC II database. Information theory was applied to quantify the expected amount of redundant information both between lab values from the same ICU day, and between consecutive ICU days. Most lab values showed a decreasing trend over time in the expected amount of novel information they contained. Platelet, blood urea nitrogen (BUN), and creatinine measurements exhibited the most amount of redundant information on days 2 and 3 compared to the previous day. The creatinine-BUN and sodium-chloride pairs had the most redundancy. Information theory can help identify and discourage unnecessary testing and bloodwork, and can in general be a useful data analytic technique for many medical specialties that deal with information overload.

  17. An audit of immunofixation requesting practices at a South African referral laboratory

    PubMed Central

    Rampursat, Yashna

    2014-01-01

    Background It is common practice in most chemical pathology laboratories for reflective immunofixation electrophoresis (IFE) to occur following the detection or suspicion of a paraprotein on serum protein electrophoresis (SPEP). The chemical pathology laboratory at Inkosi Albert Luthuli Central Hospital (IALCH) in Durban, South Africa, is currently the only non-private laboratory in the KwaZulu Natal province that performs SPEP analysis, with current practice requiring that the clinician request IFE following suggestion by the laboratory after a suspicious SPEP result. Objectives To review the current process for IFE at IALCH in the context of reflective testing and to examine the use of the alpha-2-globulin/alpha-1-globulin ratio as a predictor of a positive IFE result. Methods Data for 1260 consecutive SPEP tests performed at the IALCH National Health Laboratory Service were collected between February and July 2011. SPEP and IFE were performed with a Sebia Hydrasys automated electrophoresis system. The alpha-2-globulin/alpha-1-globulin ratio was calculated using density of corresponding fractions on SPEP. Results Analysis revealed that of the 1260 SPEPs performed during the analysis period, 304 IFEs were suggested by the reviewing pathologist. A total of 45 (15%) of the suggested IFEs were subsequently requested by the attending clinicians. Almost half (46.5%) (n = 20) of the suggested IFEs that were performed revealed the presence of a paraprotein. There was no statistically-significant difference between the alpha-2-globulin/alpha-1-globulin ratio for patients with positive or negative IFEs (p-value = 0.2). Conclusions This study reveals the need for reflective addition of IFE testing by the laboratory following suspicious findings on SPEP. PMID:29043173

  18. Current evidence and future perspectives on the effective practice of patient-centered laboratory medicine.

    PubMed

    Hallworth, Mike J; Epner, Paul L; Ebert, Christoph; Fantz, Corinne R; Faye, Sherry A; Higgins, Trefor N; Kilpatrick, Eric S; Li, Wenzhe; Rana, S V; Vanstapel, Florent

    2015-04-01

    Systematic evidence of the contribution made by laboratory medicine to patient outcomes and the overall process of healthcare is difficult to find. An understanding of the value of laboratory medicine, how it can be determined, and the various factors that influence it is vital to ensuring that the service is provided and used optimally. This review summarizes existing evidence supporting the impact of laboratory medicine in healthcare and indicates the gaps in our understanding. It also identifies deficiencies in current utilization, suggests potential solutions, and offers a vision of a future in which laboratory medicine is used optimally to support patient care. To maximize the value of laboratory medicine, work is required in 5 areas: (a) improved utilization of existing and new tests; (b) definition of new roles for laboratory professionals that are focused on optimizing patient outcomes by adding value at all points of the diagnostic brain-to-brain cycle; (c) development of standardized protocols for prospective patient-centered studies of biomarker clinical effectiveness or extraanalytical process effectiveness; (d) benchmarking of existing and new tests in specified situations with commonly accepted measures of effectiveness; (e) agreed definition and validation of effectiveness measures and use of checklists for articles submitted for publication. Progress in these areas is essential if we are to demonstrate and enhance the value of laboratory medicine and prevent valuable information being lost in meaningless data. This requires effective collaboration with clinicians, and a determination to accept patient outcome and patient experience as the primary measure of laboratory effectiveness. © 2014 American Association for Clinical Chemistry.

  19. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    PubMed

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  20. Computer validation in toxicology: historical review for FDA and EPA good laboratory practice.

    PubMed

    Brodish, D L

    1998-01-01

    The application of computer validation principles to Good Laboratory Practice is a fairly recent phenomenon. As automated data collection systems have become more common in toxicology facilities, the U.S. Food and Drug Administration and the U.S. Environmental Protection Agency have begun to focus inspections in this area. This historical review documents the development of regulatory guidance on computer validation in toxicology over the past several decades. An overview of the components of a computer life cycle is presented, including the development of systems descriptions, validation plans, validation testing, system maintenance, SOPs, change control, security considerations, and system retirement. Examples are provided for implementation of computer validation principles on laboratory computer systems in a toxicology facility.

  1. Medical errors arising from outsourcing laboratory and radiology services.

    PubMed

    Chasin, Brian S; Elliott, Sean P; Klotz, Stephen A

    2007-09-01

    Document errors and the nuisance factor inherent in the informational exchange that occurs with the outsourcing of laboratory and radiology examinations. Three infectious diseases physicians at a tertiary care hospital recorded problems involving data transmitted by telephone or fax from outsource providers for 4 months. This included in- and outpatients, and those in transition from one status to another. Outsourcing laboratory and radiology examinations of insured outpatients is a common practice. Insurance companies determine which healthcare facility performs these tests based on contractual agreements with outsource providers. This leads to confusion and frustration for the doctor and patient alike, and occasionally, to medical error. The exchange of patient data involved in outsourcing is subject to systemic errors that do not allow of easy solution.

  2. Diagnostic power of laboratory tests for hereditary spherocytosis: a comparison study in 150 patients grouped according to molecular and clinical characteristics

    PubMed Central

    Bianchi, Paola; Fermo, Elisa; Vercellati, Cristina; Marcello, Anna P.; Porretti, Laura; Cortelezzi, Agostino; Barcellini, Wilma; Zanella, Alberto

    2012-01-01

    Background The laboratory diagnosis of hereditary spherocytosis commonly relies on NaCl-based or glycerol-based red cell osmotic fragility tests; more recently, an assay directly targeting the hereditary spherocytosis molecular defect (eosin-5′-maleimide-binding test) has been proposed. None of the available tests identifies all cases of hereditary spherocytosis. Design and Methods We compared the performances of the eosin-5′-maleimide-binding test, NaCl-osmotic fragility studies on fresh and incubated blood, the glycerol lysis test, the acidified glycerol lysis test, and the Pink test on a series of 150 patients with hereditary spherocytosis grouped according to clinical phenotype and the defective protein, with the final aim of finding the combination of tests associated with the highest diagnostic power, even in the mildest cases of hereditary spherocytosis. Results The eosin-5′-maleimide-binding test had a sensitivity of 93% and a specificity of 98% for detecting hereditary spherocytosis: the sensitivity was independent of the type and amount of molecular defect and of the clinical phenotype. The acidified glycerol lysis test and Pink test showed comparable sensitivity (95% and 91%). The sensitivity of NaCl osmotic fragility tests, commonly considered the gold standard for the diagnosis of hereditary spherocytosis, was 68% on fresh blood and 81% on incubated blood, and further decreased in compensated cases (53% and 64%, respectively). The combination of the eosin-5′-maleimide-binding test and acidified glycerol lysis test enabled all patients with hereditary spherocytosis to be identified. The eosin-5′-maleimide-binding test showed the greatest disease specificity. Conclusions Each type of test fails to diagnose some cases of hereditary spherocytosis. The association of an eosin-5′-maleimide-binding test and an acidified glycerol lysis test enabled identification of all patients with hereditary spherocytosis in this series and, therefore, represents a currently effective diagnostic strategy for hereditary spherocytosis including mild/compensated cases. PMID:22058213

  3. Improving newborn screening laboratory test ordering and result reporting using health information exchange

    PubMed Central

    van Dyck, Peter C; Rinaldo, Piero; McDonald, Clement; Howell, R Rodrey; Zuckerman, Alan; Downing, Gregory

    2010-01-01

    Capture, coding and communication of newborn screening (NBS) information represent a challenge for public health laboratories, health departments, hospitals, and ambulatory care practices. An increasing number of conditions targeted for screening and the complexity of interpretation contribute to a growing need for integrated information-management strategies. This makes NBS an important test of tools and architecture for electronic health information exchange (HIE) in this convergence of individual patient care and population health activities. For this reason, the American Health Information Community undertook three tasks described in this paper. First, a newborn screening use case was established to facilitate standards harmonization for common terminology and interoperability specifications guiding HIE. Second, newborn screening coding and terminology were developed for integration into electronic HIE activities. Finally, clarification of privacy, security, and clinical laboratory regulatory requirements governing information exchange was provided, serving as a framework to establish pathways for improving screening program timeliness, effectiveness, and efficiency of quality patient care services. PMID:20064796

  4. Fever in Children: Pearls and Pitfalls

    PubMed Central

    Barbi, Egidio; Marzuillo, Pierluigi; Neri, Elena; Krauss, Baruch S.

    2017-01-01

    Fever in children is a common concern for parents and one of the most frequent presenting complaints in emergency department visits, often involving non-pediatric emergency physicians. Although the incidence of serious infections has decreased after the introduction of conjugate vaccines, fever remains a major cause of laboratory investigation and hospital admissions. Furthermore, antipyretics are the most common medications administered to children. We review the epidemiology and measurement of fever, the meaning of fever and associated clinical signs in children of different ages and under special conditions, including fever in children with cognitive impairment, recurrent fevers, and fever of unknown origin. While the majority of febrile children have mild, self-resolving viral illness, a minority may be at risk of life-threatening infections. Clinical assessment differs markedly from adult patients. Hands-off evaluation is paramount for a correct evaluation of breathing, circulation and level of interaction. Laboratory markers and clinical prediction rules provide limited help in identifying children at risk for serious infections; however, clinical examination, prudent utilization of laboratory tests, and post-discharge guidance (“safety netting”) remain the cornerstone of safe management of febrile children. PMID:28862659

  5. Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.

    PubMed

    Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli

    2018-03-13

    The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.

  6. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    PubMed

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Introduction of moribund category to OECD fish acute test and its effect on suffering and LC50 values.

    PubMed

    Rufli, Hans

    2012-05-01

    It has become common practice in many laboratories in Europe to introduce the criterion "moribund" to reduce the suffering in fish acute lethality tests. Fish with severe sublethal symptoms might be declared moribund and are removed from the test as soon as this occurs (premature discontinuation of experiment). Moribund fish affect main study outcomes as the median lethal concentration (LC50) derived on fish declared as moribund may be lower than the conventional LC50. This was evaluated by a retrospective analysis of 328 fish acute toxicity tests of an industry laboratory based on five different definitions of moribund, and of 111 tests from 10 other laboratories from Europe and the United States. Using the criterion of moribund 10 to 23% of the fish were being declared as moribund in 49 to 79% of the studies. In 36 to 52% of the studies, the LC50(moribund) was lower than the conventional LC50 depending on the definitions of moribund. An inclusion of the moribund criterion in an updated Organisation for Economic Cooperation and Development guideline for the acute fish toxicity test would reduce the period of suffering by up to 92 h, lowering the value of the main toxicity endpoint by a factor of approximately 2, and maximal by a factor of approximately 16. Copyright © 2012 SETAC.

  8. A global quantitative survey of hemostatic assessment in postpartum hemorrhage and experience with associated bleeding disorders.

    PubMed

    James, Andra H; Cooper, David L; Paidas, Michael J

    2017-01-01

    Coagulopathy may be a serious complicating or contributing factor to postpartum hemorrhage (PPH), and should be promptly recognized to ensure proper bleeding management. This study aims to evaluate the approaches of obstetrician-gynecologists worldwide towards assessing massive PPH caused by underlying bleeding disorders. A quantitative survey was completed by 302 obstetrician-gynecologists from 6 countries (the UK, France, Germany, Italy, Spain, and Japan). The survey included questions on the use of hematologic laboratory studies, interpretation of results, laboratory's role in coagulation assessments, and experience with bleeding disorders. Overall, the most common definitions of "massive" PPH were >2,000 mL (39%) and >1,500 mL (34%) blood loss. The most common criteria for rechecking a "stat" complete blood count and for performing coagulation studies were a drop in blood pressure (73%) and ongoing visible bleeding (78%), respectively. Laboratory coagulation (prothrombin time/activated partial thromboplastin time [PT/aPTT]) and factor VIII/IX assays were performed on-site more often than were mixing studies (laboratory coagulation studies, 93%; factor VIII/IX assays, 63%; mixing studies, 22%). Most commonly consulted sources of additional information were colleagues within one's own specialty (68%) and other specialists (67%). Most respondents had consulted with a hematologist (78%; least, Germany [56%]; greatest, UK [98%]). The most common reason for not consulting was hematologist unavailability (44%). The most commonly reported thresholds for concern with PT and aPTT were 13 to 20 seconds (36%) and 30 to 45 seconds (50%), respectively. Most respondents reported having discovered an underlying bleeding disorder (58%; least, Japan [35%]; greatest, Spain [74%]). Global survey results highlight similarities and differences between countries in how PPH is assessed and varying levels of obstetrician-gynecologist experience with identification of underlying bleeding disorders and engagement of hematology consultants. Opportunities to improve patient management of PPH associated with bleeding disorders include greater familiarity with interpreting PT/aPTT test results and identification of and consistent consultation with hematologists with relevant expertise.

  9. Heavy Testosterone Use Among Bodybuilders: An Uncommon Cohort of Illicit Substance Users.

    PubMed

    Westerman, Mary E; Charchenko, Cameron M; Ziegelmann, Matthew J; Bailey, George C; Nippoldt, Todd B; Trost, Landon

    2016-02-01

    To identify and characterize patterns of use among a contemporary cohort of current anabolic-androgenic steroid (AAS) users. An anonymous, self-administered, 49-item questionnaire was posted on message boards of Internet websites popular among AAS users and administered via SurveyMonkey from February 1, 2015, to June 1, 2015. Thirty-seven questions were analyzed for this study. A total of 231 male respondents met the inclusion criteria. Most were white, were older than 25 years, were employed with above average income, and had received a formal education beyond high school. Ninety-three percent began using AAS after the age of 18 years, and 81% reported using 400 mg or more of testosterone per week. Factors associated with longer duration of use (>5 years) included higher incomes (≥$75,000, P=.003), increased testosterone dosages (>600 mg per week, P=.007), older age (≥35 years, P<.001), being married (P<.001), and being self-employed (P<.001). The Internet was the most common source of testosterone (53%). Ninety-three percent used at least one additional performance-enhancing drug. Seventy-seven percent had routine laboratory tests performed, and 38% reported laboratory abnormalities at some point. Nearly all experienced subjective adverse effects while using and not using testosterone. Fifty-three percent reported use of other illegal substances, most commonly (90%) beginning before AAS initiation. Ten percent had a criminal conviction, 91% of which preceded AAS use. Fifty percent were felonies. The population of AAS users is disparate from that of other drugs of abuse. Laboratory test abnormalities and adverse effects are common and should be taken into account when counseling patients who may be using AASs. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  10. On use of the multistage dose-response model for assessing laboratory animal carcinogenicity

    PubMed Central

    Nitcheva, Daniella; Piegorsch, Walter W.; West, R. Webster

    2007-01-01

    We explore how well a statistical multistage model describes dose-response patterns in laboratory animal carcinogenicity experiments from a large database of quantal response data. The data are collected from the U.S. EPA’s publicly available IRIS data warehouse and examined statistically to determine how often higher-order values in the multistage predictor yield significant improvements in explanatory power over lower-order values. Our results suggest that the addition of a second-order parameter to the model only improves the fit about 20% of the time, while adding even higher-order terms apparently does not contribute to the fit at all, at least with the study designs we captured in the IRIS database. Also included is an examination of statistical tests for assessing significance of higher-order terms in a multistage dose-response model. It is noted that bootstrap testing methodology appears to offer greater stability for performing the hypothesis tests than a more-common, but possibly unstable, “Wald” test. PMID:17490794

  11. Zero-gravity atmospheric Cloud Physics Experiment Laboratory; Programmatics report

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The programmatics effort included comprehensive analyses in four major areas: (1) work breakdown structure, (2) schedules, (3) costs, and (4) supporting research and technology. These analyses are discussed in detail in the following sections which identify and define the laboratory project development schedule, cost estimates, funding distributions and supporting research and technology requirements. All programmatics analyses are correlated among themselves and with the technical analyses by means of the work breakdown structure which serves as a common framework for program definition. In addition, the programmatic analyses reflect the results of analyses and plans for reliability, safety, test, and maintenance and refurbishment.

  12. Low Cost Coherent Doppler Lidar Data Acquisition and Processing

    NASA Technical Reports Server (NTRS)

    Barnes, Bruce W.; Koch, Grady J.

    2003-01-01

    The work described in this paper details the development of a low-cost, short-development time data acquisition and processing system for a coherent Doppler lidar. This was done using common laboratory equipment and a small software investment. This system provides near real-time wind profile measurements. Coding flexibility created a very useful test bed for new techniques.

  13. Diagnosis of Urinary Tract Infections in Children

    PubMed Central

    2016-01-01

    Urinary tract infections (UTIs) are a common occurrence in children. The management and laboratory diagnosis of these infections pose unique challenges that are not encountered in adults. Important factors, such as specimen collection, urinalysis interpretation, culture thresholds, and antimicrobial susceptibility testing, require special consideration in children and will be discussed in detail in the following review. PMID:27053673

  14. Stereospecific Synthesis of the Geometrical Isomers of a Natural Product

    ERIC Educational Resources Information Center

    Grove, T.; DiLella, D.; Volker, E.

    2006-01-01

    Stereospecific synthesis of a geometrical isomer is not a common topic for the introductory organic chemistry laboratory. We have developed and tested an experiment for the synthesis of (Z) and (E) isomers that has been performed successfully by undergraduate students. The experiment is presented to the students as a puzzle in which they must…

  15. Vulvovaginitis: Find the cause to treat it.

    PubMed

    Goje, Oluwatosin; Munoz, Jessian L

    2017-03-01

    Vulvar and vaginal disorders are among the most common problems seen in ambulatory care. The cause is usually infectious, but noninfectious causes should also be considered, and differentiating them can be challenging. Accurate diagnosis based on patient history, physical examination, and laboratory testing is necessary so that effective therapy can be chosen. Copyright © 2017 Cleveland Clinic.

  16. Laboratory and pilot-scale bioremediation of pentaerythritol tetranitrate (PETN) contaminated soil.

    PubMed

    Zhuang, Li; Gui, Lai; Gillham, Robert W; Landis, Richard C

    2014-01-15

    PETN (pentaerythritol tetranitrate), a munitions constituent, is commonly encountered in munitions-contaminated soils, and pose a serious threat to aquatic organisms. This study investigated anaerobic remediation of PETN-contaminated soil at a site near Denver Colorado. Both granular iron and organic carbon amendments were used in both laboratory and pilot-scale tests. The laboratory results showed that, with various organic carbon amendments, PETN at initial concentrations of between 4500 and 5000mg/kg was effectively removed within 84 days. In the field trial, after a test period of 446 days, PETN mass removal of up to 53,071mg/kg of PETN (80%) was achieved with an organic carbon amendment (DARAMEND) of 4% by weight. In previous laboratory studies, granular iron has shown to be highly effective in degrading PETN. However, for both the laboratory and pilot-scale tests, granular iron was proven to be ineffective. This was a consequence of passivation of the iron surfaces caused by the very high concentrations of nitrate in the contaminated soil. This study indicated that low concentration of organic carbon was a key factor limiting bioremediation of PETN in the contaminated soil. Furthermore, the addition of organic carbon amendments such as the DARAMEND materials or brewers grain, proved to be highly effective in stimulating the biodegradation of PETN and could provide the basis for full-scale remediation of PETN-contaminated sites. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Screening for hypopituitarism in 509 patients with traumatic brain injury or subarachnoid hemorrhage.

    PubMed

    Kopczak, Anna; Kilimann, Ingo; von Rosen, Friedrich; Krewer, Carmen; Schneider, Harald Jörn; Stalla, Günter Karl; Schneider, Manfred

    2014-01-01

    We performed a screening on patients with traumatic brain injury (TBI) or subarachnoid hemorrhage (SAH) to determine the prevalence of post-traumatic hypopituitarism in neurorehabilitation in a cross-sectional, observational single-center study. In addition, the therapeutic consequences of our screening were analyzed retrospectively. From February 2006 to August 2009, patients between 18 and 65 years (n=509) with the diagnosis of TBI (n=340) or SAH (n=169) were screened within two weeks of admittance to neurorehabilitation as clinical routine. Blood was drawn to determine fasting cortisol, free thyroxine (fT4), prolactin, testosterone or estradiol, and insulin-like growth factor I (IGF-I). Patients with abnormalities in the screening or clinical signs of hypopituitarism received further stimulation tests: growth hormone releasing hormone -L-arginine-test and adrenocorticotrophic hormone (ACTH)-test (n=36); ACTH-test alone (n=26); or insulin tolerance test (n=56). In our screening of 509 patients, 28.5% showed lowered values in at least one hormone of the hypothalamus-pituitary axis and 4.5% in two or more axes. The most common disturbance was a decrease of testosterone in 40.7% of all men (in the following 13/131 men were given substitution therapy). Low fT4 was detected in 5.9% (n=3 were given substitution therapy). Low IGF-I was detected in 5.8%, low cortisol in 1.4%, and low prolactin in 0.2%; none were given substitution therapy. Further stimulation tests revealed growth hormone deficiency in 20.7% (n=19/92) and hypocortisolism in 23.7% (n=28/118). Laboratory values possibly indicating hypopituitarism (33%) were common but did not always implicate post-traumatic hypopituitarism. Laboratory values possibly indicating hypopituitarism were common in our screening but most patients were clinically not diagnosed as pituitary insufficient and did not receive hormone replacement therapy. A routine screening of all patients in neurorehabilitation without considering the time since injury, the severity of illness and therapeutic consequences seems not useful.

  18. Acceleration to failure in geophysical signals prior to laboratory rock failure and volcanic eruptions (Invited)

    NASA Astrophysics Data System (ADS)

    Main, I. G.; Bell, A. F.; Greenhough, J.; Heap, M. J.; Meredith, P. G.

    2010-12-01

    The nucleation processes that ultimately lead to earthquakes, volcanic eruptions, rock bursts in mines, and landslides from cliff slopes are likely to be controlled at some scale by brittle failure of the Earth’s crust. In laboratory brittle deformation experiments geophysical signals commonly exhibit an accelerating trend prior to dynamic failure. Similar signals have been observed prior to volcanic eruptions, including volcano-tectonic earthquake event and moment release rates. Despite a large amount of effort in the search, no such statistically robust systematic trend is found prior to natural earthquakes. Here we describe the results of a suite of laboratory tests on Mount Etna Basalt and other rocks to examine the nature of the non-linear scaling from laboratory to field conditions, notably using laboratory ‘creep’ tests to reduce the boundary strain rate to conditions more similar to those in the field. Seismic event rate, seismic moment release rate and rate of porosity change show a classic ‘bathtub’ graph that can be derived from a simple damage model based on separate transient and accelerating sub-critical crack growth mechanisms, resulting from separate processes of negative and positive feedback in the population dynamics. The signals exhibit clear precursors based on formal statistical model tests using maximum likelihood techniques with Poisson errors. After correcting for the finite loading time of the signal, the results show a transient creep rate that decays as a classic Omori law for earthquake aftershocks, and remarkably with an exponent near unity, as commonly observed for natural earthquake sequences. The accelerating trend follows an inverse power law when fitted in retrospect, i.e. with prior knowledge of the failure time. In contrast the strain measured on the sample boundary shows a less obvious but still accelerating signal that is often absent altogether in natural strain data prior to volcanic eruptions. To test the forecasting power of such constitutive rules in prospective mode, we examine the forecast quality of several synthetic trials, by adding representative statistical fluctuations, due to finite real-time sampling effects, to an underlying accelerating trend. Metrics of forecast quality change systematically and dramatically with time. In particular the model accuracy increases, and the forecast bias decreases, as the failure time approaches.

  19. Rapid and Adaptable Measurement of Protein Thermal Stability by Differential Scanning Fluorimetry: Updating a Common Biochemical Laboratory Experiment

    ERIC Educational Resources Information Center

    Johnson, R. Jeremy; Savas, Christopher J.; Kartje, Zachary; Hoops, Geoffrey C.

    2014-01-01

    Measurement of protein denaturation and protein folding is a common laboratory technique used in undergraduate biochemistry laboratories. Differential scanning fluorimetry (DSF) provides a rapid, sensitive, and general method for measuring protein thermal stability in an undergraduate biochemistry laboratory. In this method, the thermal…

  20. Integrated field and laboratory tests to evaluate effects of metals-impacted wetlands on amphibians: A case study from Montana

    USGS Publications Warehouse

    Linder, G.; ,

    2003-01-01

    Mining activities frequently impact wildlife habitats, and a wide range of habitats may require evaluations of the linkages between wildlife and environmental stressors common to mining activities (e.g., physical alteration of habitat, releases of chemicals such as metals and other inorganic constituents as part of the mining operation). Wetlands, for example, are frequently impacted by mining activities. Within an ecological assessment for a wetland, toxicity evaluations for representative species may be advantageous to the site evaluation, since these species could be exposed to complex chemical mixtures potentially released from the site. Amphibian species common to these transition zones between terrestrial and aquatic habitats are one key biological indicator of exposure, and integrated approaches which involve both field and laboratory methods focused on amphibians are critical to the assessment process. The laboratory and field evaluations of a wetland in western Montana illustrates the integrated approach to risk assessment and causal analysis. Here, amphibians were used to evaluate the potential toxicity associated with heavy metal-laden sediments deposited in a reservoir. Field and laboratory methods were applied to a toxicity assessment for metals characteristic of mine tailings to reduce potential "lab to field" extrapolation errors and provide adaptive management programs with critical site-specific information targeted on remediation.

  1. Screening protocols to monitor respiratory status in primary immunodeficiency disease: findings from a European survey and subclinical infection working group.

    PubMed

    Jolles, S; Sánchez-Ramón, S; Quinti, I; Soler-Palacín, P; Agostini, C; Florkin, B; Couderc, L-J; Brodszki, N; Jones, A; Longhurst, H; Warnatz, K; Haerynck, F; Matucci, A; de Vries, E

    2017-11-01

    Many patients with primary immunodeficiency (PID) who have antibody deficiency develop progressive lung disease due to underlying subclinical infection and inflammation. To understand how these patients are monitored we conducted a retrospective survey based on patient records of 13 PID centres across Europe, regarding the care of 1061 adult and 178 paediatric patients with PID on immunoglobulin (Ig) G replacement. The most common diagnosis was common variable immunodeficiency in adults (75%) and hypogammaglobulinaemia in children (39%). The frequency of clinic visits varied both within and between centres: every 1-12 months for adult patients and every 3-6 months for paediatric patients. Patients diagnosed with lung diseases were more likely to receive pharmaceutical therapies and received a wider range of therapies than patients without lung disease. Variation existed between centres in the frequency with which some clinical and laboratory monitoring tests are performed, including exercise tests, laboratory testing for IgG subclass levels and specific antibodies, and lung function tests such as spirometry. Some tests were carried out more frequently in adults than in children, probably due to difficulties conducting these tests in younger children. The percentage of patients seen regularly by a chest physician, or who had microbiology tests performed following chest and sinus exacerbations, also varied widely between centres. Our survey revealed a great deal of variation across Europe in how frequently patients with PID visit the clinic and how frequently some monitoring tests are carried out. These results highlight the urgent need for consensus guidelines on how to monitor lung complications in PID patients. © 2017 The Authors. Clinical and Experimental Immunology published by John Wiley & Sons Ltd on behalf of British Society for Immunology.

  2. Screening protocols to monitor respiratory status in primary immunodeficiency disease: findings from a European survey and subclinical infection working group

    PubMed Central

    Sánchez‐Ramón, S.; Quinti, I.; Soler‐Palacín, P.; Agostini, C.; Florkin, B.; Couderc, L.‐J.; Brodszki, N.; Jones, A.; Longhurst, H.; Warnatz, K.; Haerynck, F.; Matucci, A.; de Vries, E.

    2017-01-01

    Summary Many patients with primary immunodeficiency (PID) who have antibody deficiency develop progressive lung disease due to underlying subclinical infection and inflammation. To understand how these patients are monitored we conducted a retrospective survey based on patient records of 13 PID centres across Europe, regarding the care of 1061 adult and 178 paediatric patients with PID on immunoglobulin (Ig) G replacement. The most common diagnosis was common variable immunodeficiency in adults (75%) and hypogammaglobulinaemia in children (39%). The frequency of clinic visits varied both within and between centres: every 1–12 months for adult patients and every 3–6 months for paediatric patients. Patients diagnosed with lung diseases were more likely to receive pharmaceutical therapies and received a wider range of therapies than patients without lung disease. Variation existed between centres in the frequency with which some clinical and laboratory monitoring tests are performed, including exercise tests, laboratory testing for IgG subclass levels and specific antibodies, and lung function tests such as spirometry. Some tests were carried out more frequently in adults than in children, probably due to difficulties conducting these tests in younger children. The percentage of patients seen regularly by a chest physician, or who had microbiology tests performed following chest and sinus exacerbations, also varied widely between centres. Our survey revealed a great deal of variation across Europe in how frequently patients with PID visit the clinic and how frequently some monitoring tests are carried out. These results highlight the urgent need for consensus guidelines on how to monitor lung complications in PID patients. PMID:28708268

  3. [Tasks and duties of veterinary reference laboratories for food borne zoonoses].

    PubMed

    Ellerbroek, Lüppo; Alter, T; Johne, R; Nöckler, K; Beutin, L; Helmuth, R

    2009-02-01

    Reference laboratories are of central importance for consumer protection. Field expertise and high scientific competence are basic requirements for the nomination of a national reference laboratory. To ensure a common approach in the analysis of zoonotic hazards, standards have been developed by the reference laboratories together with national official laboratories on the basis of Art. 33 of Directive (EG) No. 882/2004. Reference laboratories function as arbitrative boards in the case of ambivalent or debatable results. New methods for detection of zoonotic agents are developed and validated to provide tools for analysis, e. g., in legal cases, if results from different parties are disputed. Besides these tasks, national reference laboratories offer capacity building and advanced training courses and control the performance of ring trials to ensure consistency in the quality of analyses in official laboratories. All reference laboratories work according to the ISO standard 17025 which defines the grounds for strict laboratory quality rules and in cooperation with the respective Community Reference Laboratories (CRL). From the group of veterinary reference laboratories for food-borne zoonoses, the national reference laboratories are responsible for Listeria monocytogenes, for Campylobacter, for the surveillance and control of viral and bacterial contamination of bivalve molluscs, for E. coli, for the performance of analysis and tests on zoonoses (Salmonella), and from the group of parasitological zoonotic agents, the national reference laboratory for Trichinella.

  4. Deconvolution of noisy transient signals: a Kalman filtering application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candy, J.V.; Zicker, J.E.

    The deconvolution of transient signals from noisy measurements is a common problem occuring in various tests at Lawrence Livermore National Laboratory. The transient deconvolution problem places atypical constraints on algorithms presently available. The Schmidt-Kalman filter, a time-varying, tunable predictor, is designed using a piecewise constant model of the transient input signal. A simulation is developed to test the algorithm for various input signal bandwidths and different signal-to-noise ratios for the input and output sequences. The algorithm performance is reasonable.

  5. Olodaterol and vilanterol detection in sport drug testing.

    PubMed

    Chundela, Zdenek; Große, Joachim

    2015-01-01

    The possibility of the detection of olodaterol and vilanterol, two novel β2 -agonists, in human urine for the purpose of sport drug testing was investigated. Compounds of interest were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) employing methods commonly used in the World Anti-Doping Agency (WADA) accredited laboratories. For both substances, the respective parent compound was found to be a suitable target analyte for monitoring therapeutic dose administration. Copyright © 2015 John Wiley & Sons, Ltd.

  6. From High-Throughput Microarray-Based Screening to Clinical Application: The Development of a Second Generation Multigene Test for Breast Cancer Prognosis

    PubMed Central

    Brase, Jan C.; Kronenwett, Ralf; Petry, Christoph; Denkert, Carsten; Schmidt, Marcus

    2013-01-01

    Several multigene tests have been developed for breast cancer patients to predict the individual risk of recurrence. Most of the first generation tests rely on proliferation-associated genes and are commonly carried out in central reference laboratories. Here, we describe the development of a second generation multigene assay, the EndoPredict test, a prognostic multigene expression test for estrogen receptor (ER) positive, human epidermal growth factor receptor (HER2) negative (ER+/HER2−) breast cancer patients. The EndoPredict gene signature was initially established in a large high-throughput microarray-based screening study. The key steps for biomarker identification are discussed in detail, in comparison to the establishment of other multigene signatures. After biomarker selection, genes and algorithms were transferred to a diagnostic platform (reverse transcription quantitative PCR (RT-qPCR)) to allow for assaying formalin-fixed, paraffin-embedded (FFPE) samples. A comprehensive analytical validation was performed and a prospective proficiency testing study with seven pathological laboratories finally proved that EndoPredict can be reliably used in the decentralized setting. Three independent large clinical validation studies (n = 2,257) demonstrated that EndoPredict offers independent prognostic information beyond current clinicopathological parameters and clinical guidelines. The review article summarizes several important steps that should be considered for the development process of a second generation multigene test and offers a means for transferring a microarray signature from the research laboratory to clinical practice. PMID:27605191

  7. Acute porphyrias in the USA: features of 108 subjects from porphyrias consortium.

    PubMed

    Bonkovsky, Herbert L; Maddukuri, Vinaya C; Yazici, Cemal; Anderson, Karl E; Bissell, D Montgomery; Bloomer, Joseph R; Phillips, John D; Naik, Hetanshi; Peter, Inga; Baillargeon, Gwen; Bossi, Krista; Gandolfo, Laura; Light, Carrie; Bishop, David; Desnick, Robert J

    2014-12-01

    Recent descriptions of the clinical and laboratory features of subjects with acute porphyrias in the US are lacking. Our aim was to describe clinical, biochemical, and genetic features of 108 subjects. Between September 2010 and December 2012, 108 subjects with acute porphyrias (90 acute intermittent porphyrias, 9 hereditary coproporphyrias, 9 variegate porphyrias) were enrolled into an observational study. Genetic testing was performed at a central genetic testing laboratory and clinical information entered into a central database. Selected features were compared with data for adults in the US. Most subjects (88/108, 81%) were female, with self-reported onset of symptoms in the second through fourth decades of life. The most common symptom was abdominal pain. Appendectomies and cholecystectomies were common before a diagnosis of porphyria. The diagnosis was delayed by a mean of 15 years. Anxiety and depression were common, and 18% complained of chronic symptoms, especially neuropathic and other pains. The incidences of systemic arterial hypertension, chronic kidney disease, seizure disorders, and psychiatric conditions were markedly increased. Mutations of the known causative genes were found in 102/105 of those tested, with novel mutations being found in 37, including in 7/8 subjects with hereditary coproporphyria. Therapy with intravenous hematin was the most effective therapy both for treatment of acute attacks and for prevention of recurrent attacks. Acute porphyrias often remain undiagnosed for more than a decade after first symptoms develop. Intravenous hematin is the treatment of choice, both for treatment of acute attacks and for prevention of recurrent attacks. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.

    PubMed

    HarsimranKaur, Vikram Narang; Selhi, Pavneet Kaur; Sood, Neena; Singh, Aminder

    2016-01-01

    Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to evaluate the types and frequency of preanalytical errors in hematology laboratory of our center. All the samples received in the Hematology Laboratory of Dayanand Medical College and Hospital, Ludhiana, India over a period of one year (July 2013-July 2014) were included in the study and preanalytical variables like clotted samples, quantity not sufficient, wrong sample, without label, wrong label were studied. Of 471,006 samples received in the laboratory, preanalytical errors, as per the above mentioned categories was found in 1802 samples. The most common error was clotted samples (1332 samples, 0.28% of the total samples) followed by quantity not sufficient (328 sample, 0.06%), wrong sample (96 samples, 0.02%), without label (24 samples, 0.005%) and wrong label (22 samples, 0.005%). Preanalytical errors are frequent in laboratories and can be corrected by regular analysis of the variables involved. Rectification can be done by regular education of the staff.

  9. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    PubMed

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  10. Specialized sperm function tests in varicocele and the future of andrology laboratory

    PubMed Central

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele. PMID:26780873

  11. Clinical and laboratory variability in a cohort of patients diagnosed with type 1 VWD in the United States

    PubMed Central

    Christopherson, Pamela A.; Gill, Joan Cox; Friedman, Kenneth D.; Haberichter, Sandra L.; Bellissimo, Daniel B.; Udani, Rupa A.; Dasgupta, Mahua; Hoffmann, Raymond G.; Ragni, Margaret V.; Shapiro, Amy D.; Lusher, Jeanne M.; Lentz, Steven R.; Abshire, Thomas C.; Leissinger, Cindy; Hoots, W. Keith; Manco-Johnson, Marilyn J.; Gruppo, Ralph A.; Boggio, Lisa N.; Montgomery, Kate T.; Goodeve, Anne C.; James, Paula D.; Lillicrap, David; Peake, Ian R.; Montgomery, Robert R.

    2016-01-01

    von Willebrand disease (VWD) is the most common inherited bleeding disorder, and type 1 VWD is the most common VWD variant. Despite its frequency, diagnosis of type 1 VWD remains the subject of debate. In order to study the spectrum of type 1 VWD in the United States, the Zimmerman Program enrolled 482 subjects with a previous diagnosis of type 1 VWD without stringent laboratory diagnostic criteria. von Willebrand factor (VWF) laboratory testing and full-length VWF gene sequencing was performed for all index cases and healthy control subjects in a central laboratory. Bleeding phenotype was characterized using the International Society on Thrombosis and Haemostasis bleeding assessment tool. At study entry, 64% of subjects had VWF antigen (VWF:Ag) or VWF ristocetin cofactor activity below the lower limit of normal, whereas 36% had normal VWF levels. VWF sequence variations were most frequent in subjects with VWF:Ag <30 IU/dL (82%), whereas subjects with type 1 VWD and VWF:Ag ≥30 IU/dL had an intermediate frequency of variants (44%). Subjects whose VWF testing was normal at study entry had a similar rate of sequence variations as the healthy controls (14%). All subjects with severe type 1 VWD and VWF:Ag ≤5 IU/dL had an abnormal bleeding score (BS), but otherwise BS did not correlate with VWF:Ag. Subjects with a historical diagnosis of type 1 VWD had similar rates of abnormal BS compared with subjects with low VWF levels at study entry. Type 1 VWD in the United States is highly variable, and bleeding symptoms are frequent in this population. PMID:26862110

  12. Clinical and laboratory variability in a cohort of patients diagnosed with type 1 VWD in the United States.

    PubMed

    Flood, Veronica H; Christopherson, Pamela A; Gill, Joan Cox; Friedman, Kenneth D; Haberichter, Sandra L; Bellissimo, Daniel B; Udani, Rupa A; Dasgupta, Mahua; Hoffmann, Raymond G; Ragni, Margaret V; Shapiro, Amy D; Lusher, Jeanne M; Lentz, Steven R; Abshire, Thomas C; Leissinger, Cindy; Hoots, W Keith; Manco-Johnson, Marilyn J; Gruppo, Ralph A; Boggio, Lisa N; Montgomery, Kate T; Goodeve, Anne C; James, Paula D; Lillicrap, David; Peake, Ian R; Montgomery, Robert R

    2016-05-19

    von Willebrand disease (VWD) is the most common inherited bleeding disorder, and type 1 VWD is the most common VWD variant. Despite its frequency, diagnosis of type 1 VWD remains the subject of debate. In order to study the spectrum of type 1 VWD in the United States, the Zimmerman Program enrolled 482 subjects with a previous diagnosis of type 1 VWD without stringent laboratory diagnostic criteria. von Willebrand factor (VWF) laboratory testing and full-length VWF gene sequencing was performed for all index cases and healthy control subjects in a central laboratory. Bleeding phenotype was characterized using the International Society on Thrombosis and Haemostasis bleeding assessment tool. At study entry, 64% of subjects had VWF antigen (VWF:Ag) or VWF ristocetin cofactor activity below the lower limit of normal, whereas 36% had normal VWF levels. VWF sequence variations were most frequent in subjects with VWF:Ag <30 IU/dL (82%), whereas subjects with type 1 VWD and VWF:Ag ≥30 IU/dL had an intermediate frequency of variants (44%). Subjects whose VWF testing was normal at study entry had a similar rate of sequence variations as the healthy controls (14%). All subjects with severe type 1 VWD and VWF:Ag ≤5 IU/dL had an abnormal bleeding score (BS), but otherwise BS did not correlate with VWF:Ag. Subjects with a historical diagnosis of type 1 VWD had similar rates of abnormal BS compared with subjects with low VWF levels at study entry. Type 1 VWD in the United States is highly variable, and bleeding symptoms are frequent in this population. © 2016 by The American Society of Hematology.

  13. Reliability, robustness, and reproducibility in mouse behavioral phenotyping: a cross-laboratory study

    PubMed Central

    Mandillo, Silvia; Tucci, Valter; Hölter, Sabine M.; Meziane, Hamid; Banchaabouchi, Mumna Al; Kallnik, Magdalena; Lad, Heena V.; Nolan, Patrick M.; Ouagazzal, Abdel-Mouttalib; Coghill, Emma L.; Gale, Karin; Golini, Elisabetta; Jacquot, Sylvie; Krezel, Wojtek; Parker, Andy; Riet, Fabrice; Schneider, Ilka; Marazziti, Daniela; Auwerx, Johan; Brown, Steve D. M.; Chambon, Pierre; Rosenthal, Nadia; Tocchini-Valentini, Glauco; Wurst, Wolfgang

    2008-01-01

    Establishing standard operating procedures (SOPs) as tools for the analysis of behavioral phenotypes is fundamental to mouse functional genomics. It is essential that the tests designed provide reliable measures of the process under investigation but most importantly that these are reproducible across both time and laboratories. For this reason, we devised and tested a set of SOPs to investigate mouse behavior. Five research centers were involved across France, Germany, Italy, and the UK in this study, as part of the EUMORPHIA program. All the procedures underwent a cross-validation experimental study to investigate the robustness of the designed protocols. Four inbred reference strains (C57BL/6J, C3HeB/FeJ, BALB/cByJ, 129S2/SvPas), reflecting their use as common background strains in mutagenesis programs, were analyzed to validate these tests. We demonstrate that the operating procedures employed, which includes open field, SHIRPA, grip-strength, rotarod, Y-maze, prepulse inhibition of acoustic startle response, and tail flick tests, generated reproducible results between laboratories for a number of the test output parameters. However, we also identified several uncontrolled variables that constitute confounding factors in behavioral phenotyping. The EUMORPHIA SOPs described here are an important start-point for the ongoing development of increasingly robust phenotyping platforms and their application in large-scale, multicentre mouse phenotyping programs. PMID:18505770

  14. Stress and anxiety effects on positive skin test responses in young adults with allergic rhinitis.

    PubMed

    Heffner, Kathi L; Kiecolt-Glaser, Janice K; Glaser, Ronald; Malarkey, William B; Marshall, Gailen D

    2014-07-01

    Anxiety and psychological stress affect allergy-related immune function. How these relations influence the evaluations of patients with allergic rhinitis is unknown. To examine whether anxiety and stress exposure affect skin prick test (SPT) responses to common allergens for which patients with atopy showed no prior positive SPT response. Patients with allergic rhinitis, evidenced by clinical history and SPT results, were admitted twice to a hospital research unit for 4 hours. In a crossover design, SPT wheals were assessed before and after the Trier Social Stress Test and then the following morning; for comparison, SPT wheals were assessed before and after a laboratory session without a stressor. Analyses focused on wheal responses for common allergens that tested negative (wheal size <3 mm larger than saline) from SPTs performed at multiple baseline assessments. After the Trier Social Stress Test, more anxious patients with atopy had a higher incidence of positive SPT reactions to antigens that previously tested negative. Anxiety was unrelated to positive SPT incidence under nonstressful conditions. Based on clinical symptom reports, newly positive SPT reactions after the stressor were apparently corrections of previously false-negative SPT reactions. The SPT wheal responses for allergens previously testing negative were enhanced after a stressor. Histamine (positive control) or saline (negative control) SPT responses were not affected. A laboratory stressor affected allergen SPT responses in more anxious patients with allergic rhinitis. In addition to clinical history, assessment of anxiety and current stress at the time of the SPT may provide valuable information about a patient's allergic status and aid in clinical decision making. Copyright © 2014 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  15. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes: A GeT-RM Collaborative Project.

    PubMed

    Pratt, Victoria M; Everts, Robin E; Aggarwal, Praful; Beyer, Brittany N; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A; Smith, Chingying Huang; Toji, Lorraine H; Turner, Amy; Kalman, Lisa V

    2016-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  16. Correlation between microdilution, Etest, and disk diffusion methods for antifungal susceptibility testing of fluconazole against Candida sp. blood isolates.

    PubMed

    Menezes, Everardo Albuquerque; Vasconcelos Júnior, Antônio Alexandre de; Ângelo, Maria Rozzelê Ferreira; Cunha, Maria da Conceição dos Santos Oliveira; Cunha, Francisco Afrânio

    2013-01-01

    Antifungal susceptibility testing assists in finding the appropriate treatment for fungal infections, which are increasingly common. However, such testing is not very widespread. There are several existing methods, and the correlation between such methods was evaluated in this study. The susceptibility to fluconazole of 35 strains of Candida sp. isolated from blood cultures was evaluated by the following methods: microdilution, Etest, and disk diffusion. The correlation between the methods was around 90%. The disk diffusion test exhibited a good correlation and can be used in laboratory routines to detect strains of Candida sp. that are resistant to fluconazole.

  17. Microbiological survey of mice (Mus musculus) purchased from commercial pet shops in Kanagawa and Tokyo, Japan.

    PubMed

    Hayashimoto, Nobuhito; Morita, Hanako; Ishida, Tomoko; Uchida, Ritsuki; Tanaka, Mai; Ozawa, Midori; Yasuda, Masahiko; Itoh, Toshio

    2015-01-01

    Information regarding the prevalence of infectious agents in mice in pet shops in Japan is scarce. This information is particularly useful for minimizing the risk of potential transmission of infections to laboratory mice. Therefore, we surveyed infectious agents in mice from pet shops in Kanagawa and Tokyo, Japan. The survey was conducted in 28 mice from 5 pet shops to screen for 47 items (17 viruses, 22 bacteria and fungi, 10 parasites) using culture tests, serology, PCR, and microscopy. The most common viral agent detected was murine norovirus (17 mice; 60.7%), followed by Theiler's murine encephalomyelitis virus (13 mice; 46.4%), and mouse hepatitis virus (12 mice; 42.8%). The most common agent amongst the bacteria and fungi was Pasteurella pneumotropica (10 mice; 35.7%), followed by Helicobacter ganmani and Pneumocystis murina (8 mice; 28.5%, for both). Tritrichomonas muris was the most common parasite (19 mice; 67.8%), followed by Spironucleus muris (13 mice; 46.4%), Aspiculuris tetraptera, and Syphacia obvelata (8 mice each; 28.5%). Remarkably, a zoonotic agent, Hymenolepis nana, was found in 7 mice (25%). Given these results, we suggest that the workers in laboratory animal facilities should recognize again the potential risks of mice outside of the laboratory animal facilities as an infectious source, and avoid keeping mice as pets or as feed for carnivorous reptiles as much as possible for risk management.

  18. Song Recognition without Identification: When People Cannot "Name that Tune" but Can Recognize It as Familiar

    ERIC Educational Resources Information Center

    Kostic, Bogdan; Cleary, Anne M.

    2009-01-01

    Recognition without identification (RWI) is a common day-to-day experience (as when recognizing a face or a tune as familiar without being able to identify the person or the song). It is also a well-established laboratory-based empirical phenomenon: When identification of recognition test items is prevented, participants can discriminate between…

  19. Effect of Fungal Competition on Decay Rates in Bicultured Soil Bottle Assays

    Treesearch

    Grant T. Kirker; Amy Blodgett; Patricia K. Lebow; Carol A. Clausen

    2016-01-01

    For decades, wood scientists and preservative formulators have employed the monocultured soil bottle assay to test efficacy of wood treatment in the laboratory as a rapid predictor of field performance. This study examines the effects of bicultured soil bottle assays on the decay by common wood decay fungi. Mycelial interactions were noted in early stages of...

  20. Gyroscopic Instruments for Instrument Flying

    NASA Technical Reports Server (NTRS)

    Brombacher, W G; Trent, W C

    1938-01-01

    The gyroscopic instruments commonly used in instrument flying in the United States are the turn indicator, the directional gyro, the gyromagnetic compass, the gyroscopic horizon, and the automatic pilot. These instruments are described. Performance data and the method of testing in the laboratory are given for the turn indicator, the directional gyro, and the gyroscopic horizon. Apparatus for driving the instruments is discussed.

  1. Rapid Methods for the Laboratory Identification of Pathogenic Microorganisms.

    DTIC Science & Technology

    1981-09-01

    Preliminary results provide strong evidence to show that the fungi, Candida and Cryptococcus , can be raoidly differentiated by a lectin test. SFor Oro...SUMMATION LECTIN-YEAST INTERACTIONS Objective: To find a lectin that selectively agglutinates Cryptococcus neoformans (the etiologic agent of...peanut), Conavalia ensiformis (Con A) and mango extract may potentially be utilized to differentiate Cryptococcus from the other yeasts most commonly

  2. Materials Technology: The Common Core Skills That are Shaping the Future. Final Performance Report. January 1, 1989-June 30, 1990.

    ERIC Educational Resources Information Center

    Battelle Pacific Northwest Laboratories, Richland, WA.

    A materials technology program was developed at Richland High School (Washington) and pilot tested at seven sites in Washington and Oregon. The program created partnerships between science and vocational education teachers at Richland High and Battelle Pacific Northwest Laboratories, and was then expanded to include other high schools, colleges,…

  3. Comparison of Three Commercial Systems for Identification of Yeasts Commonly Isolated in the Clinical Microbiology Laboratory

    PubMed Central

    Wadlin, Jill K.; Hanko, Gayle; Stewart, Rebecca; Pape, John; Nachamkin, Irving

    1999-01-01

    We evaluated three commercial systems (RapID Yeast Plus System; Innovative Diagnostic Systems, Norcross, Ga.; API 20C Aux; bioMerieux-Vitek, Hazelwood, Mo.; and Vitek Yeast Biochemical Card, bioMerieux-Vitek) against an auxinographic and microscopic morphologic reference method for the ability to identify yeasts commonly isolated in our clinical microbiology laboratory. Two-hundred one yeast isolates were compared in the study. The RapID Yeast Plus System was significantly better than either API 20C Aux (193 versus 167 correct identifications; P < 0.0001) or the Vitek Yeast Biochemical Card (193 versus 173 correct identifications; P = 0.003) for obtaining correct identifications to the species level without additional testing. There was no significant difference between results obtained with API 20C Aux and the Vitek Yeast Biochemical Card system (P = 0.39). The API 20C Aux system did not correctly identify any of the Candida krusei isolates (n = 23) without supplemental testing and accounted for the major differences between the API 20C Aux and RapID Yeast Plus systems. Overall, the RapID Yeast Plus System was easy to use and is a good system for the routine identification of clinically relevant yeasts. PMID:10325356

  4. Preferred Names, Preferred Pronouns, and Gender Identity in the Electronic Medical Record and Laboratory Information System: Is Pathology Ready?

    PubMed

    Imborek, Katherine L; Nisly, Nicole L; Hesseltine, Michael J; Grienke, Jana; Zikmund, Todd A; Dreyer, Nicholas R; Blau, John L; Hightower, Maia; Humble, Robert M; Krasowski, Matthew D

    2017-01-01

    Electronic medical records (EMRs) and laboratory information systems (LISs) commonly utilize patient identifiers such as legal name, sex, medical record number, and date of birth. There have been recommendations from some EMR working groups (e.g., the World Professional Association for Transgender Health) to include preferred name, pronoun preference, assigned sex at birth, and gender identity in the EMR. These practices are currently uncommon in the United States. There has been little published on the potential impact of these changes on pathology and LISs. We review the available literature and guidelines on the use of preferred name and gender identity on pathology, including data on changes in laboratory testing following gender transition treatments. We also describe pathology and clinical laboratory challenges in the implementation of preferred name at our institution. Preferred name, pronoun preference, and gender identity have the most immediate impact on the areas of pathology with direct patient contact such as phlebotomy and transfusion medicine, both in terms of interaction with patients and policies for patient identification. Gender identity affects the regulation and policies within transfusion medicine including blood donor risk assessment and eligibility. There are limited studies on the impact of gender transition treatments on laboratory tests, but multiple studies have demonstrated complex changes in chemistry and hematology tests. A broader challenge is that, even as EMRs add functionality, pathology computer systems (e.g., LIS, middleware, reference laboratory, and outreach interfaces) may not have functionality to store or display preferred name and gender identity. Implementation of preferred name, pronoun preference, and gender identity presents multiple challenges and opportunities for pathology.

  5. Preferred Names, Preferred Pronouns, and Gender Identity in the Electronic Medical Record and Laboratory Information System: Is Pathology Ready?

    PubMed Central

    Imborek, Katherine L.; Nisly, Nicole L.; Hesseltine, Michael J.; Grienke, Jana; Zikmund, Todd A.; Dreyer, Nicholas R.; Blau, John L.; Hightower, Maia; Humble, Robert M.; Krasowski, Matthew D.

    2017-01-01

    Background: Electronic medical records (EMRs) and laboratory information systems (LISs) commonly utilize patient identifiers such as legal name, sex, medical record number, and date of birth. There have been recommendations from some EMR working groups (e.g., the World Professional Association for Transgender Health) to include preferred name, pronoun preference, assigned sex at birth, and gender identity in the EMR. These practices are currently uncommon in the United States. There has been little published on the potential impact of these changes on pathology and LISs. Methods: We review the available literature and guidelines on the use of preferred name and gender identity on pathology, including data on changes in laboratory testing following gender transition treatments. We also describe pathology and clinical laboratory challenges in the implementation of preferred name at our institution. Results: Preferred name, pronoun preference, and gender identity have the most immediate impact on the areas of pathology with direct patient contact such as phlebotomy and transfusion medicine, both in terms of interaction with patients and policies for patient identification. Gender identity affects the regulation and policies within transfusion medicine including blood donor risk assessment and eligibility. There are limited studies on the impact of gender transition treatments on laboratory tests, but multiple studies have demonstrated complex changes in chemistry and hematology tests. A broader challenge is that, even as EMRs add functionality, pathology computer systems (e.g., LIS, middleware, reference laboratory, and outreach interfaces) may not have functionality to store or display preferred name and gender identity. Conclusions: Implementation of preferred name, pronoun preference, and gender identity presents multiple challenges and opportunities for pathology. PMID:29114436

  6. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.

    PubMed

    Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca

    2018-05-08

    Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Clinical exome sequencing reports: current informatics practice and future opportunities.

    PubMed

    Swaminathan, Rajeswari; Huang, Yungui; Astbury, Caroline; Fitzgerald-Butt, Sara; Miller, Katherine; Cole, Justin; Bartlett, Christopher; Lin, Simon

    2017-11-01

    The increased adoption of clinical whole exome sequencing (WES) has improved the diagnostic yield for patients with complex genetic conditions. However, the informatics practice for handling information contained in whole exome reports is still in its infancy, as evidenced by the lack of a common vocabulary within clinical sequencing reports generated across genetic laboratories. Genetic testing results are mostly transmitted using portable document format, which can make secondary analysis and data extraction challenging. This paper reviews a sample of clinical exome reports generated by Clinical Laboratory Improvement Amendments-certified genetic testing laboratories at tertiary-care facilities to assess and identify common data elements. Like structured radiology reports, which enable faster information retrieval and reuse, structuring genetic information within clinical WES reports would help facilitate integration of genetic information into electronic health records and enable retrospective research on the clinical utility of WES. We identify elements listed as mandatory according to practice guidelines but are currently missing from some of the clinical reports, which might help to organize the data when stored within structured databases. We also highlight elements, such as patient consent, that, although they do not appear within any of the current reports, may help in interpreting some of the information within the reports. Integrating genetic and clinical information would assist the adoption of personalized medicine for improved patient care and outcomes. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.

    PubMed

    Lo, Y C; Armbruster, David A

    2012-04-01

    Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.

  9. NACA Lewis Researcher and Technicians Discuss a Test Setup

    NASA Image and Video Library

    1956-12-21

    Researcher Bill Reiwaldt discusses the preparations for a test in the Altitude Wind Tunnel with technicians Jack Wagner and Dick Golladay at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. Research engineers developed ideas for tests that were often in response to requests from the military or aircraft industry. Arrangements were made to obtain an engine for the study and to transport it to the Cleveland laboratory. The engine was brought into the facility’s shop area, where it was readied for investigation. It was common for several different engines to be worked on simultaneously in the shop. The researcher would discuss the engine and the test objectives with the Test Installation Division and the facility’s technicians. The operations team would handle the installation of the instrumentation and fitting the test into the facility’s schedule. Upon completion of the previous test, the engine was removed. The next engine was lifted by an overhead crane and transported from the shop to the test section. The engine was connected to the measurement devices and fuel and oil supply lines. Engines were tested over numerous runs under varying conditions and with variations on the configuration. The findings and test procedure were then described in research or technical memorandums and distributed to industry.

  10. [Do we always correctly interpret the results of statistical nonparametric tests].

    PubMed

    Moczko, Jerzy A

    2014-01-01

    Mann-Whitney, Wilcoxon, Kruskal-Wallis and Friedman tests create a group of commonly used tests to analyze the results of clinical and laboratory data. These tests are considered to be extremely flexible and their asymptotic relative efficiency exceeds 95 percent. Compared with the corresponding parametric tests they do not require checking the fulfillment of the conditions such as the normality of data distribution, homogeneity of variance, the lack of correlation means and standard deviations, etc. They can be used both in the interval and or-dinal scales. The article presents an example Mann-Whitney test, that does not in any case the choice of these four nonparametric tests treated as a kind of gold standard leads to correct inference.

  11. Genetic horoscopes: is it all in the genes? Points for regulatory control of direct-to-consumer genetic testing

    PubMed Central

    Patch, Christine; Sequeiros, Jorge; Cornel, Martina C

    2009-01-01

    The development of tests for genetic susceptibility to common complex diseases has raised concerns. These concerns relate to evaluation of the scientific and clinical validity and utility of the tests, quality assurance of laboratories and testing services, advice and protection for the consumer and the appropriate regulatory and policy response. How these concerns are interpreted and addressed is an ongoing debate. If the possibility of using the discoveries from genomic science to improve health is to be realised without losing public confidence, then improvements in the evaluation and mechanisms for control of supply of tests may be as important as the science itself. PMID:19259126

  12. Genetic horoscopes: is it all in the genes? Points for regulatory control of direct-to-consumer genetic testing.

    PubMed

    Patch, Christine; Sequeiros, Jorge; Cornel, Martina C

    2009-07-01

    The development of tests for genetic susceptibility to common complex diseases has raised concerns. These concerns relate to evaluation of the scientific and clinical validity and utility of the tests, quality assurance of laboratories and testing services, advice and protection for the consumer and the appropriate regulatory and policy response. How these concerns are interpreted and addressed is an ongoing debate. If the possibility of using the discoveries from genomic science to improve health is to be realised without losing public confidence, then improvements in the evaluation and mechanisms for control of supply of tests may be as important as the science itself.

  13. Routine testing of Mycoplasma genitalium and Trichomonas vaginalis.

    PubMed

    Jenniskens, Marieke L M; Veerbeek, Jan H W; Deurloo, Koen L; van Hannen, Erik J; Thijsen, Steven F T

    2017-06-01

    Mycoplasma genitalium (MG) and Trichomonas vaginalis (TV) are common sexual transmitted infections (STI). However, most STI screening programmes do not include routinely detection of these pathogens. Consequently, epidemiological data about MG and TV in the general population is lacking. The current study aims to give insight into the prevalence of both infections, thereby guiding decisions whether testing for these pathogens should be included routinely. Between February 2013 and August 2015, all samples sent to the laboratory of Diakonessenhuis Utrecht for STI testing (i.e. testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG)) were additionally examined for the presence of MG and TV by means of a laboratory-developed RT-PCR. Samples were collected by our hospital or by regional general practitioners. A total of 5628 PCR's were evaluated. In 7.5%, one or more STI were detected. CT was found in 5% and MG was positive in 1.9%. NG was detected in 0.5% and TV was detected in 0.6% of the samples. CT was found more often in primary care than in hospital setting (9.7% vs. 3.0%, p < .05). The same was shown for NG (1.1% vs. 0.2%, p < .05). More men than women were positive for CT (11.2% vs. 3.8%, p < .05) and NG (1.4% vs. 0.3%, p < .05). MG is more prevalent than NG and TV in a regional Dutch population. Furthermore, TV is equally common as NG. Based on our prevalence data, including MG and TV in STI testing protocols should be considered in the future.

  14. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part IV - postanalytic considerations.

    PubMed

    Barnett, David; Louzao, Raaul; Gambell, Peter; De, Jitakshi; Oldaker, Teri; Hanson, Curtis A

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called home brew assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part IV - Postanalytic considerations. © 2013 International Clinical Cytometry Society.

  15. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part II - preanalytical issues.

    PubMed

    Davis, Bruce H; Dasgupta, Amar; Kussick, Steven; Han, Jin-Yeong; Estrellado, Annalee

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part II - Preanalytical issues. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.

  16. Implementation of the Xpert MTB/RIF assay for tuberculosis in Mongolia: a qualitative exploration of barriers and enablers.

    PubMed

    Rendell, Nicole L; Bekhbat, Solongo; Ganbaatar, Gantungalag; Dorjravdan, Munkhjargal; Pai, Madhukar; Dobler, Claudia C

    2017-01-01

    The aim of our study was to identify barriers and enablers to implementation of the Xpert MTB/RIF test within Mongolia's National Tuberculosis Program. Twenty-foursemi-structured interviews were conducted between June and September 2015 with laboratory staff and tuberculosis physicians in Mongolia's capital Ulaanbaatar and regional towns where Xpert MTB/RIF testing had been implemented. Interviews were recorded, transcribed, translated and analysed thematically using NVIVO qualitative analysis software. Eight laboratory staff (five from the National Tuberculosis Reference Laboratory in Ulaanbaatar and three from provincial laboratories) and sixteen tuberculosis physicians (five from the Mongolian National Center for Communicable Diseases in Ulaanbaatar, four from district tuberculosis clinics in Ulaanbaatar and seven from provincial tuberculosis clinics) were interviewed. Major barriers to Xpert MTB/RIF implementation identified were: lack of awareness of program guidelines; inadequate staffing arrangements; problems with cartridge supply management; lack of local repair options for the Xpert machines; lack of regular formal training; paper based system; delayed treatment initiation due to consensus meeting and poor sample quality. Enablers to Xpert MTB/RIF implementation included availability of guidelines in the local language; provision of extra laboratory staff, shift working arrangements and additional modules; capacity for troubleshooting internally; access to experts; opportunities for peer learning; common understanding of diagnostic algorithms and decentralised testing. Our study identified a number of barriers and enablers to implementation of Xpert MTB/RIF in the Mongolian National Tuberculosis Program. Lessons learned from this study can help to facilitate implementation of Xpert MTB/RIF in other Mongolian locations as well as other low-and middle-income countries.

  17. Verification of an Automated, Digital Dispensing Platform for At-Will Broth Microdilution-Based Antimicrobial Susceptibility Testing.

    PubMed

    Smith, Kenneth P; Kirby, James E

    2016-09-01

    With rapid emergence of multidrug-resistant bacteria, there is often a need to perform susceptibility testing for less commonly used or newer antimicrobial agents. Such testing can often be performed only by using labor-intensive, manual dilution methods and lies outside the capacity of most clinical labs, necessitating reference laboratory testing and thereby delaying the availability of susceptibility data. To address the compelling clinical need for microbiology laboratories to perform such testing in-house, we explored a novel, automated, at-will broth microdilution-based susceptibility testing platform. Specifically, we used the modified inkjet printer technology in the HP D300 digital dispensing system to dispense, directly from stock solutions into a 384-well plate, the 2-fold serial dilution series required for broth microdilution testing. This technology was combined with automated absorbance readings and data analysis to determine MICs. Performance was verified by testing members of the Enterobacteriaceae for susceptibility to ampicillin, cefazolin, ciprofloxacin, colistin, gentamicin, meropenem, and tetracycline in comparison to the results obtained with a broth microdilution reference standard. In precision studies, essential and categorical agreement levels were 96.8% and 98.3%, respectively. Furthermore, significantly fewer D300-based measurements were outside ±1 dilution from the modal MIC, suggesting enhanced reproducibility. In accuracy studies performed using a panel of 80 curated clinical isolates, rates of essential and categorical agreement and very major, major, and minor errors were 94%, 96.6%, 0%, 0%, and 3.4%, respectively. Based on these promising initial results, it is anticipated that the D300-based methodology will enable hospital-based clinical microbiology laboratories to perform at-will broth microdilution testing of antimicrobials and to address a critical testing gap. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. Testing antimicrobial paint efficacy on gypsum wallboard contaminated with Stachybotrys chartarum.

    PubMed

    Menetrez, M Y; Foarde, K K; Webber, T D; Dean, T R; Betancourt, D A

    2008-02-01

    The goal of this research was to reduce occupant exposure to indoor mold through the efficacy testing of antimicrobial paints. An accepted method for handling Stachybotrys chartarum-contaminated gypsum wallboard (GWB) is removal and replacement. This practice is also recommended for water-damaged or mold-contaminated GWB but is not always followed completely. The efficacy of antimicrobial paints to eliminate or control mold regrowth on surfaces can be tested easily on nonporous surfaces. The testing of antimicrobial efficacy on porous surfaces found in the indoor environment, such as gypsum wallboard, can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold S. chartarum has been studied for toxin production and its occurrence in water-damaged buildings. Research to control its growth using seven different antimicrobial paints and two commonly used paints on contaminated, common gypsum wallboard was performed in laboratory testing at high relative humidity. The results indicate differences in antimicrobial efficacy for the period of testing, and that proper cleaning and resurfacing of GWB with an antimicrobial paint can be an option in those unique circumstances when removal may not be possible.

  19. Review: Properties of sperm and seminal fluid, informed by research on reproduction and contraception.

    PubMed

    Cotton, Robin W; Fisher, Matthew B

    2015-09-01

    Forensic DNA testing is grounded in molecular biology and population genetics. The technologies that were the basis of restriction length polymorphism testing (RFLP) have given way to PCR based technologies. While PCR has been the pillar of short tandem repeat (STR) methods and will continue to be used as DNA sequencing and analysis of single nucleotide polymorphisms (SNPs) are introduced into human identification, the molecular biology techniques in use today represent significant advances since the introduction of STR testing. Large forensic laboratories with dedicated research teams and forensic laboratories which are part of academic institutions have the resources to keep track of advances which can then be considered for further research or incorporated into current testing methods. However, many laboratories have limited ability to keep up with research advances outside of the immediate area of forensic science and may not have access to a large university library systems. This review focuses on filling this gap with respect to areas of research that intersect with selected methods used in forensic biology. The review summarizes information collected from several areas of the scientific literature where advances in molecular biology have produced information relevant to DNA analysis of sexual assault evidence and methods used in presumptive and confirmatory identification of semen. Older information from the literature is also included where this information may not be commonly known and is relevant to current methods. The topics selected highlight (1) information from applications of proteomics to sperm biology and human reproduction, (2) seminal fluid proteins and prostate cancer diagnostics, (3) developmental biology of sperm from the fertility literature and (4) areas where methods are common to forensic analysis and research in contraceptive use and monitoring. Information and progress made in these areas coincide with the research interests of forensic biology and cross-talk between these disciplines may benefit both. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  1. Blood collection tubes as medical devices: The potential to affect assays and proposed verification and validation processes for the clinical laboratory.

    PubMed

    Bowen, Raffick A R; Adcock, Dorothy M

    2016-12-01

    Blood collection tubes (BCTs) are an often under-recognized variable in the preanalytical phase of clinical laboratory testing. Unfortunately, even the best-designed and manufactured BCTs may not work well in all clinical settings. Clinical laboratories, in collaboration with healthcare providers, should carefully evaluate BCTs prior to putting them into clinical use to determine their limitations and ensure that patients are not placed at risk because of inaccuracies due to poor tube performance. Selection of the best BCTs can be achieved through comparing advertising materials, reviewing the literature, observing the device at a scientific meeting, receiving a demonstration, evaluating the device under simulated conditions, or testing the device with patient samples. Although many publications have discussed method validations, few detail how to perform experiments for tube verification and validation. This article highlights the most common and impactful variables related to BCTs and discusses the validation studies that a typical clinical laboratory should perform when selecting BCTs. We also present a brief review of how in vitro diagnostic devices, particularly BCTs, are regulated in the United States, the European Union, and Canada. The verification and validation of BCTs will help to avoid the economic and human costs associated with incorrect test results, including poor patient care, unnecessary testing, and delays in test results. We urge laboratorians, tube manufacturers, diagnostic companies, and other researchers to take all the necessary steps to protect against the adverse effects of BCT components and their additives on clinical assays. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Presentation of laboratory test results in patient portals: influence of interface design on risk interpretation and visual search behaviour.

    PubMed

    Fraccaro, Paolo; Vigo, Markel; Balatsoukas, Panagiotis; van der Veer, Sabine N; Hassan, Lamiece; Williams, Richard; Wood, Grahame; Sinha, Smeeta; Buchan, Iain; Peek, Niels

    2018-02-12

    Patient portals are considered valuable instruments for self-management of long term conditions, however, there are concerns over how patients might interpret and act on the clinical information they access. We hypothesized that visual cues improve patients' abilities to correctly interpret laboratory test results presented through patient portals. We also assessed, by applying eye-tracking methods, the relationship between risk interpretation and visual search behaviour. We conducted a controlled study with 20 kidney transplant patients. Participants viewed three different graphical presentations in each of low, medium, and high risk clinical scenarios composed of results for 28 laboratory tests. After viewing each clinical scenario, patients were asked how they would have acted in real life if the results were their own, as a proxy of their risk interpretation. They could choose between: 1) Calling their doctor immediately (high interpreted risk); 2) Trying to arrange an appointment within the next 4 weeks (medium interpreted risk); 3) Waiting for the next appointment in 3 months (low interpreted risk). For each presentation, we assessed accuracy of patients' risk interpretation, and employed eye tracking to assess and compare visual search behaviour. Misinterpretation of risk was common, with 65% of participants underestimating the need for action across all presentations at least once. Participants found it particularly difficult to interpret medium risk clinical scenarios. Participants who consistently understood when action was needed showed a higher visual search efficiency, suggesting a better strategy to cope with information overload that helped them to focus on the laboratory tests most relevant to their condition. This study confirms patients' difficulties in interpreting laboratories test results, with many patients underestimating the need for action, even when abnormal values were highlighted or grouped together. Our findings raise patient safety concerns and may limit the potential of patient portals to actively involve patients in their own healthcare.

  3. Approach to Patient with a Generalized Rash

    PubMed Central

    Leung, Lawrence; Soeyonggo, Tony

    2013-01-01

    Background: Generalized rash is amongst the most common conditions presented to practicing General Practitioners and common differentials include contact dermatitis, atopic eczema, sun-induced damage, drug eruption and general manifestations of systemic diseases or infections. Materials and Methods: We illustrate with differential diagnoses our clinical case of a generalized rash in a 55-year-old man with pathognomonic signs of a diagnosis, which has received increasing global concern. Conclusion: Despite the array of available laboratory tests, a detailed history and physical examination is still of paramount importance to arrive at the most likely diagnosis for any patient with a generalized skin rash. PMID:26664833

  4. Predictive value and efficiency of laboratory testing.

    PubMed

    Galen, R S

    1980-11-01

    Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.

  5. Health hazards associated with the use of di-(2-ethylhexyl) phthalate (commonly referred to as DOP) in HEPA filter test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-01-01

    Di-(2-ethylhexyl) phthalate (DEHP), commonly referred to as di-octyl phthalate, is an important production chemical in the US. In addition to its major use as an additive in plastics, DEHP is widely used to evaluate the effectiveness of high efficiency particulate air (HEPA) filters. Historically, DEHP was also used in quantitative fit testing for respirators. Evaluations of this compound a decade ago showed that it can induce hepatocellular carcinomas in laboratory animals. Although most Department of Energy (DOE) facilities have since discontinued using DEHP in respirator fit testing, DEHP continues to be used for evaluating HEPA filters. This report summarizes availablemore » information on the toxicity, mutagenicity, carcinogenicity, and other hazards and problems posed by DEHP, specifically with reference to HEPA filter testing. Information on work practice improvements as well as the availability and suitability of DEHP substitutes are also presented. This material should assist the DOE in the safe use of this material.« less

  6. Using Dragonflies as Common, Flexible & Charismatic Subjects for Teaching the Scientific Process

    ERIC Educational Resources Information Center

    Switzer, Paul V.

    2007-01-01

    Biology laboratories are usually designed around convenient and available subjects. For example, for animal laboratories "Daphnia magna," "Drosophila melanogaster," frogs, rats, and mice are common animals that are relatively easy to obtain, relatively cheap, and consequently lend themselves well to laboratory experimentation. On many campuses, …

  7. Ebola Preparedness: Diagnosis Improvement Using Rapid Approaches for Proficiency Testing

    PubMed Central

    Lau, Katherine A.; Theis, Torsten; Gray, Joanna

    2016-01-01

    ABSTRACT The unprecedented 2015 Ebolavirus (EBOV) outbreak in West Africa was declared a public health emergency, making diagnosis and quality of testing a global issue. The accuracy of laboratory diagnostic capacity for EBOV was assessed in 2014 to 2016 using a proficiency testing (PT) strategy developed by the Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) in Biosecurity. Following a literature search, EBOV-specific gene targets were ranked according to the frequency of their use in published methods. The most commonly used gene regions (nucleoprotein [NP], glycoprotein [GP], and RNA-dependent RNA polymerase [L]) were selected for the design of in vitro RNA transcripts to be included in the simulated EBOV specimens used for EBOV detection with PCR-based assays. Specimens were tested for stability and found to be stable on long-term storage (1 year) at −80°C and on shorter-term storage in lyophilized form (1 week at ambient temperature and a subsequent week at −80°C). These specimens were used in three EBOV PTs offered from April 2014 to March 2016. In the first and third PTs, all laboratories (3/3 and 9/9, respectively) correctly identified specimens containing EBOV RNA transcripts, while in the second PT, all but one laboratory (5/6) correctly confirmed the presence of EBOV. The EBOV PT panel was useful for ensuring the competency of laboratories in detecting EBOV in the absence of readily available clinical samples. The simulated EBOV specimen was safe, stable, and reliable and can be used in lyophilized form for future EBOV PT programs, allowing simplicity of transport. PMID:27974537

  8. Principles of laboratory assessment of drug abuse liability and implications for clinical development

    PubMed Central

    Carter, Lawrence P.; Griffiths, Roland R.

    2009-01-01

    Abuse liability testing plays an important role in informing drug development, regulatory processes, and clinical practice. This paper describes the current “gold standard” methodologies that are used for laboratory assessments of abuse liability in non-human and human subjects. Particular emphasis is given to procedures such as non-human drug discrimination, self-administration, and physical dependence testing, and human dose effect abuse liability studies that are commonly used in regulatory submissions to governmental agencies. The potential benefits and risks associated with the inclusion of measures of abuse liability in industry-sponsored clinical trials is discussed. Lastly, it is noted that many factors contribute to patterns of drug abuse and dependence outside of the laboratory setting and positive or negative signals in abuse liability studies do not always translate to high or low levels of actual abuse or dependence. Well-designed patient and physician education, pharmacovigilance, and postmarketing surveillance can reduce the diversion and misuse of drugs with abuse liability and can effectively foster the protection and promotion of public health. PMID:19443137

  9. Artificial Neural Network for Total Laboratory Automation to Improve the Management of Sample Dilution.

    PubMed

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.

  10. Evaluating the effectiveness of common disinfectants at preventing the propagation of Mycobacterium spp. isolated from zebrafish

    PubMed Central

    Chang, Carolyn T.; Colicino, Erica G.; DiPaola, Elizabeth J.; Al-Hasnawi, Hadi Jabbar; Whipps, Christopher M.

    2016-01-01

    Mycobacteriosis is a bacterial disease that is common in captive, wild and research fish. There is no one causative agent of mycobacteriosis, as several strains and species of Mycobacterium have been identified in zebrafish. With increased usage and investment in wild-type and mutant zebrafish strains, considerable value is placed on preserving zebrafish health. One control measure used to prevent mycobacterial spread within and between zebrafish facilities is egg disinfection. Here we investigate the effectiveness of three disinfectants [chlorine bleach, hydrogen peroxide, and povidone iodine (PVPI)] commonly included in egg disinfection protocols for laboratory fish as well as aquaculture fish and compare the knockdown effect of these treatments on Mycobacterium spp. in vitro. Despite current usage, comparison of these disinfection regimes’ abilities to prevent mycobacterial growth has not been tested. We found that the germicidal effect of different disinfectants vary by Mycobacterium spp.. Hydrogen peroxide was the least effective disinfectant, followed by unbuffered chlorine bleach, which is commonly used to disinfect embryos in zebrafish facilities. Disinfection with 25 ppm PVPI for 5 min was very effective, and may be an improved alternative to chlorine bleach for embryo disinfection. Results from this study can be utilized by laboratory fish facilities in order to prevent the spread of mycobacteriosis in research fish. PMID:26423444

  11. The effect of restructuring student writing in the general chemistry laboratory on student understanding of chemistry and on students' approach to the laboratory course

    NASA Astrophysics Data System (ADS)

    Rudd, James Andrew, II

    Many students encounter difficulties engaging with laboratory-based instruction, and reviews of research have indicated that the value of such instruction is not clearly evident. Traditional forms of writing associated with laboratory activities are commonly in a style used by professional scientists to communicate developed explanations. Students probably lack the interpretative skills of a professional, and writing in this style may not support students in learning how to develop scientific explanations. The Science Writing Heuristic (SWH) is an inquiry-based approach to laboratory instruction designed in part to promote student ability in developing such explanations. However, there is not a convincing body of evidence for the superiority of inquiry-based laboratory instruction in chemistry. In a series of studies, the performance of students using the SWH student template in place of the standard laboratory report format was compared to the performance of students using the standard format. The standard reports had Title, Purpose, Procedure, Data & Observations, Calculations & Graphs, and Discussion sections. The SWH reports had Beginning Questions & Ideas, Tests & Procedures, Observations, Claims, Evidence, and Reflection sections. The pilot study produced evidence that using the SWH improved the quality of laboratory reports, improved student performance on a laboratory exam, and improved student approach to laboratory work. A main study found that SWH students statistically exhibited a better understanding of physical equilibrium when written explanations and equations were analyzed on a lecture exam and performed descriptively better on a physical equilibrium practical exam task. In another main study, the activities covering the general equilibrium concept were restructured as an additional change, and it was found that SWH students exhibited a better understanding of chemical equilibrium as shown by statistically greater success in overcoming the common confusion of interpreting equilibrium as equal concentrations and by statistically better performance when explaining aspects of chemical equilibrium. Both main studies found that students and instructors spent less time on the SWH reports and that students preferred the SWH approach because it increased their level of mental engagement. The studies supported the conclusion that inquiry-based laboratory instruction benefits student learning and attitudes.

  12. Utility of laboratory studies in seizures of children older than one month of age.

    PubMed

    Karbasi, S Akhavan; Mosadegh, M Modares; Fallah, R

    2009-08-01

    Seizure is the most common paediatric neurological disease which occurs in ten percent of children. In approaching a convulsive patient, finding the causes of seizure is essential, and the patient's history as well as the physical examination are important. The role of routine laboratory tests for children's seizures (except neonates) is undetermined, but checking for serum sodium, glucose, calcium and urea routinely has been advised. The purpose of this study was to determine the diagnostic efficacy of these serum chemistry tests in the seizures of children older than one month of age. In this descriptive, retrospective study, medical records of 302 hospitalised children with seizure were reviewed. Results of laboratory tests, like sodium, calcium, blood glucose and urea levels, pertinent history and physical examination, and the change in patient management based on serum chemistry test results, were analysed. All the children in the study were classified as having seizure with or without fever. In 302 hospitalised children with seizure, about ten percent of 938 tests were abnormal. 27.7 percent of these abnormal results were seen in 1-12-month-old infants. Only 11 percent of abnormal tests (1.3 percent of total tests) might have caused a seizure. Also, 0.2 percent of the results could not be predicted from the history or physical examination, which was conducted in patients younger than one year of age. Routine determination of serum chemistry values in seizures of children does not contribute to therapy, and are costly and time-consuming. It may not be helpful and informative unless the patient is less than one year of age.

  13. The EC4 European syllabus for post-graduate training in clinical chemistry and laboratory medicine: version 4--2012.

    PubMed

    Wieringa, Gijsbert; Zerah, Simone; Jansen, Rob; Simundic, Ana-Maria; Queralto, José; Solnica, Bogdan; Gruson, Damien; Tomberg, Karel; Riittinen, Leena; Baum, Hannsjörg; Brochet, Jean-Philippe; Buhagiar, Gerald; Charilaou, Charis; Grigore, Camelia; Johnsen, Anders H; Kappelmayer, Janos; Majkic-Singh, Nada; Nubile, Giuseppe; O'Mullane, John; Opp, Matthias; Pupure, Silvija; Racek, Jaroslav; Reguengo, Henrique; Rizos, Demetrios; Rogic, Dunja; Špaňár, Július; Štrakl, Greta; Szekeres, Thomas; Tzatchev, Kamen; Vitkus, Dalius; Wallemacq, Pierre; Wallinder, Hans

    2012-08-01

    Laboratory medicine's practitioners across the European community include medical, scientific and pharmacy trained specialists whose contributions to health and healthcare is in the application of diagnostic tests for screening and early detection of disease, differential diagnosis, monitoring, management and treatment of patients, and their prognostic assessment. In submitting a revised common syllabus for post-graduate education and training across the 27 member states an expectation is set for harmonised, high quality, safe practice. In this regard an extended 'Core knowledge, skills and competencies' division embracing all laboratory medicine disciplines is described. For the first time the syllabus identifies the competencies required to meet clinical leadership demands for defining, directing and assuring the efficiency and effectiveness of laboratory services as well as expectations in translating knowledge and skills into ability to practice. In a 'Specialist knowledge' division, the expectations from the individual disciplines of Clinical Chemistry/Immunology, Haematology/Blood Transfusion, Microbiology/ Virology, Genetics and In Vitro Fertilisation are described. Beyond providing a common platform of knowledge, skills and competency, the syllabus supports the aims of the European Commission in providing safeguards to increasing professional mobility across European borders at a time when demand for highly qualified professionals is increasing and the labour force is declining. It continues to act as a guide for the formulation of national programmes supplemented by the needs of individual country priorities.

  14. Experimental Extinguishment of Fires by Blast.

    DTIC Science & Technology

    1982-05-01

    Icopmy DTIC TAB I Unan-nounced Approved by: Justiri cat i O__ : R. C. Phillips, Director Chemical Engineering Laboratory D1str1i.:: to,/ G. R...SRI study. Of interest this year has been the role played by fuel type--notably, the Dertinent physico- chemical properties--compared with the...perturbing geometries on fire behavior. Present tests on common liquid fuels representing various combinations of physico- chemical properties demonstrate

  15. Argonne National Laboratory Li-alloy/FeS cell testing and R and D programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gay, E.C.

    1982-01-01

    Groups of 12 or more identical Li-alloy/FeS cells fabricated by Eagle-Picher Industries, Inc. and Gould Inc. were operated at Argonne National Laboratory (ANL) in the status cell test program to obtain data for statistical analysis of cell cycle life and failure modes. The cells were full-size electric vehicle battery cells (150 to 350 Ah capacity) and they were cycled at the 4-h discharge rate and 8-h charge rate. The end of life was defined as a 20% loss of capacity or a decrease in the coulombic efficiency to less than 95%. Seventy-four cells (six groups of identical cells) were cycle-lifemore » tested and the results were analyzed statistically. The ultimate goal of this analysis was to predict cell and battery reliability. Testing of groups of identical cells also provided a means of identifying common failure modes which were eliminated by cell design changes. Mean time to failure (MTTF) for the cells based on the Weibull distribution is presented.« less

  16. Nutritional Supplementation and Meal Timing

    NASA Astrophysics Data System (ADS)

    Farris, Jim

    For the competitive athlete and the serious recreational athlete, nutritional supplementation can have a positive effect on training and on performance. There are many fad supplements on the market, and many that have come and gone. However, two nutrients have withstood the test of time and many tests in research laboratories around the world, and they continue to have positive training- and performance-enhancing effects. Carbohydrates are commonly supplemented to improve energy availability and to replace valuable muscle and liver glycogen stores. Protein supplementation usually is associated with building muscle tissue.

  17. Reducing unnecessary lab testing in the ICU with artificial intelligence.

    PubMed

    Cismondi, F; Celi, L A; Fialho, A S; Vieira, S M; Reti, S R; Sousa, J M C; Finkelstein, S N

    2013-05-01

    To reduce unnecessary lab testing by predicting when a proposed future lab test is likely to contribute information gain and thereby influence clinical management in patients with gastrointestinal bleeding. Recent studies have demonstrated that frequent laboratory testing does not necessarily relate to better outcomes. Data preprocessing, feature selection, and classification were performed and an artificial intelligence tool, fuzzy modeling, was used to identify lab tests that do not contribute an information gain. There were 11 input variables in total. Ten of these were derived from bedside monitor trends heart rate, oxygen saturation, respiratory rate, temperature, blood pressure, and urine collections, as well as infusion products and transfusions. The final input variable was a previous value from one of the eight lab tests being predicted: calcium, PTT, hematocrit, fibrinogen, lactate, platelets, INR and hemoglobin. The outcome for each test was a binary framework defining whether a test result contributed information gain or not. Predictive modeling was applied to recognize unnecessary lab tests in a real world ICU database extract comprising 746 patients with gastrointestinal bleeding. Classification accuracy of necessary and unnecessary lab tests of greater than 80% was achieved for all eight lab tests. Sensitivity and specificity were satisfactory for all the outcomes. An average reduction of 50% of the lab tests was obtained. This is an improvement from previously reported similar studies with average performance 37% by [1-3]. Reducing frequent lab testing and the potential clinical and financial implications are an important issue in intensive care. In this work we present an artificial intelligence method to predict the benefit of proposed future laboratory tests. Using ICU data from 746 patients with gastrointestinal bleeding, and eleven measurements, we demonstrate high accuracy in predicting the likely information to be gained from proposed future lab testing for eight common GI related lab tests. Future work will explore applications of this approach to a range of underlying medical conditions and laboratory tests. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Reducing unnecessary lab testing in the ICU with artificial intelligence

    PubMed Central

    Cismondi, F.; Celi, L.A.; Fialho, A.S.; Vieira, S.M.; Reti, S.R.; Sousa, J.M.C.; Finkelstein, S.N.

    2017-01-01

    Objectives To reduce unnecessary lab testing by predicting when a proposed future lab test is likely to contribute information gain and thereby influence clinical management in patients with gastrointestinal bleeding. Recent studies have demonstrated that frequent laboratory testing does not necessarily relate to better outcomes. Design Data preprocessing, feature selection, and classification were performed and an artificial intelligence tool, fuzzy modeling, was used to identify lab tests that do not contribute an information gain. There were 11 input variables in total. Ten of these were derived from bedside monitor trends heart rate, oxygen saturation, respiratory rate, temperature, blood pressure, and urine collections, as well as infusion products and transfusions. The final input variable was a previous value from one of the eight lab tests being predicted: calcium, PTT, hematocrit, fibrinogen, lactate, platelets, INR and hemoglobin. The outcome for each test was a binary framework defining whether a test result contributed information gain or not. Patients Predictive modeling was applied to recognize unnecessary lab tests in a real world ICU database extract comprising 746 patients with gastrointestinal bleeding. Main results Classification accuracy of necessary and unnecessary lab tests of greater than 80% was achieved for all eight lab tests. Sensitivity and specificity were satisfactory for all the outcomes. An average reduction of 50% of the lab tests was obtained. This is an improvement from previously reported similar studies with average performance 37% by [1–3]. Conclusions Reducing frequent lab testing and the potential clinical and financial implications are an important issue in intensive care. In this work we present an artificial intelligence method to predict the benefit of proposed future laboratory tests. Using ICU data from 746 patients with gastrointestinal bleeding, and eleven measurements, we demonstrate high accuracy in predicting the likely information to be gained from proposed future lab testing for eight common GI related lab tests. Future work will explore applications of this approach to a range of underlying medical conditions and laboratory tests. PMID:23273628

  19. Analysis of laboratory compaction methods of roller compacted concrete

    NASA Astrophysics Data System (ADS)

    Trtík, Tomáš; Chylík, Roman; Bílý, Petr; Fládr, Josef

    2017-09-01

    Roller-Compacted Concrete (RCC) is an ordinary concrete poured and compacted with machines typically used for laying of asphalt road layers. One of the problems connected with this technology is preparation of representative samples in the laboratory. The aim of this work was to analyse two methods of preparation of RCC laboratory samples with bulk density as the comparative parameter. The first method used dynamic compaction by pneumatic hammer. The second method of compaction had a static character. The specimens were loaded by precisely defined force in laboratory loading machine to create the same conditions as during static rolling (in the Czech Republic, only static rolling is commonly used). Bulk densities obtained by the two compaction methods were compared with core drills extracted from real RCC structure. The results have shown that the samples produced by pneumatic hammer tend to overestimate the bulk density of the material. For both compaction methods, immediate bearing index test was performed to verify the quality of compaction. A fundamental difference between static and dynamic compaction was identified. In static compaction, initial resistance to penetration of the mandrel was higher, after exceeding certain limit the resistance was constant. This means that the samples were well compacted just on the surface. Specimens made by pneumatic hammer actively resisted throughout the test, the whole volume was uniformly compacted.

  20. Two-sample tests and one-way MANOVA for multivariate biomarker data with nondetects.

    PubMed

    Thulin, M

    2016-09-10

    Testing whether the mean vector of a multivariate set of biomarkers differs between several populations is an increasingly common problem in medical research. Biomarker data is often left censored because some measurements fall below the laboratory's detection limit. We investigate how such censoring affects multivariate two-sample and one-way multivariate analysis of variance tests. Type I error rates, power and robustness to increasing censoring are studied, under both normality and non-normality. Parametric tests are found to perform better than non-parametric alternatives, indicating that the current recommendations for analysis of censored multivariate data may have to be revised. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    NASA Astrophysics Data System (ADS)

    Alexandru, Mioara; Ene, Mihaela

    2007-08-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services—industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006.

  2. Final report on the design and development of a Rolling Float Meter for drilling-fluid outflow measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staller, G.E.; Westmoreland, J.J.; Whitlow, G.L.

    1998-03-01

    Lost circulation, which is the loss of well drilling fluids to the formation while drilling, is a common problem encountered while drilling geothermal wells. The rapid detection of the loss of well drilling fluids is critical to the successful and cost-effective treatment of the wellbore to stop or minimize lost circulation. Sandia National Laboratories has developed an instrument to accurately measure the outflow rate of drilling fluids while drilling. This instrument, the Rolling Float Meter, has been under development at Sandia since 1991 and is now available for utilization by interested industry users. This report documents recent Rolling Float Metermore » design upgrades resulting from field testing and industry input, the effects of ongoing testing and evaluation both in the laboratory and in the field, and the final design package that is available to transfer this technology to industry users.« less

  3. Outsourcing of Academic Clinical Laboratories

    PubMed Central

    Mrak, Robert E.; Parslow, Tristram G.; Tomaszewski, John E.

    2018-01-01

    American hospitals are increasingly turning to service outsourcing to reduce costs, including laboratory services. Studies of this practice have largely focused on nonacademic medical centers. In contrast, academic medical centers have unique practice environments and unique mission considerations. We sought to elucidate and analyze clinical laboratory outsourcing experiences in US academic medical centers. Seventeen chairs of pathology with relevant experience were willing to participate in in-depth interviews about their experiences. Anticipated financial benefits from joint venture arrangements often eroded after the initial years of the agreement, due to increased test pricing, management fees, duplication of services in support of inpatients, and lack of incentive for utilization control on the part of the for-profit partner. Outsourcing can preclude development of lucrative outreach programs; such programs were successfully launched in several cases after joint ventures were either avoided or terminated. Common complaints included poor test turnaround time and problems with test quality (especially in molecular pathology, microbiology, and flow cytometry), leading to clinician dissatisfaction. Joint ventures adversely affected retention of academically oriented clinical pathology faculty, with adverse effects on research and education, which further exacerbated clinician dissatisfaction due to lack of available consultative expertise. Resident education in pathology and in other disciplines (especially infectious disease) suffered both from lack of on-site laboratory capabilities and from lack of teaching faculty. Most joint ventures were initiated with little or no input from pathology leadership, and input from pathology leadership was seen to have been critical in those cases where such arrangements were declined or terminated. PMID:29637086

  4. The false security of blind dates: chrononymization's lack of impact on data privacy of laboratory data.

    PubMed

    Cimino, J J

    2012-01-01

    The reuse of clinical data for research purposes requires methods for the protection of personal privacy. One general approach is the removal of personal identifiers from the data. A frequent part of this anonymization process is the removal of times and dates, which we refer to as "chrononymization." While this step can make the association with identified data (such as public information or a small sample of patient information) more difficult, it comes at a cost to the usefulness of the data for research. We sought to determine whether removal of dates from common laboratory test panels offers any advantage in protecting such data from re-identification. We obtained a set of results for 5.9 million laboratory panels from the National Institutes of Health's (NIH) Biomedical Translational Research Information System (BTRIS), selected a random set of 20,000 panels from the larger source sets, and then identified all matches between the sets. We found that while removal of dates could hinder the re-identification of a single test result, such removal had almost no effect when entire panels were used. Our results suggest that reliance on chrononymization provides a false sense of security for the protection of laboratory test results. As a result of this study, the NIH has chosen to rely on policy solutions, such as strong data use agreements, rather than removal of dates when reusing clinical data for research purposes.

  5. Biosafety and Biosecurity: A Relative Risk-Based Framework for Safer, More Secure, and Sustainable Laboratory Capacity Building.

    PubMed

    Dickmann, Petra; Sheeley, Heather; Lightfoot, Nigel

    2015-01-01

    Laboratory capacity building is characterized by a paradox between endemicity and resources: countries with high endemicity of pathogenic agents often have low and intermittent resources (water, electricity) and capacities (laboratories, trained staff, adequate regulations). Meanwhile, countries with low endemicity of pathogenic agents often have high-containment facilities with costly infrastructure and maintenance governed by regulations. The common practice of exporting high biocontainment facilities and standards is not sustainable and concerns about biosafety and biosecurity require careful consideration. A group at Chatham House developed a draft conceptual framework for safer, more secure, and sustainable laboratory capacity building. The draft generic framework is guided by the phrase "LOCAL - PEOPLE - MAKE SENSE" that represents three major principles: capacity building according to local needs (local) with an emphasis on relationship and trust building (people) and continuous outcome and impact measurement (make sense). This draft generic framework can serve as a blueprint for international policy decision-making on improving biosafety and biosecurity in laboratory capacity building, but requires more testing and detailing development.

  6. The Induction of Chaos in Electronic Circuits Final Report-October 1, 2001

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.M.Wheat, Jr.

    2003-04-01

    This project, now known by the name ''Chaos in Electronic Circuits,'' was originally tasked as a two-year project to examine various ''fault'' or ''non-normal'' operational states of common electronic circuits with some focus on determining the feasibility of exploiting these states. Efforts over the two-year duration of this project have been dominated by the study of the chaotic behavior of electronic circuits. These efforts have included setting up laboratory space and hardware for conducting laboratory tests and experiments, acquiring and developing computer simulation and analysis capabilities, conducting literature surveys, developing test circuitry and computer models to exercise and test ourmore » capabilities, and experimenting with and studying the use of RF injection as a means of inducing chaotic behavior in electronics. An extensive array of nonlinear time series analysis tools have been developed and integrated into a package named ''After Acquisition'' (AA), including capabilities such as Delayed Coordinate Embedding Mapping (DCEM), Time Resolved (3-D) Fourier Transform, and several other phase space re-creation methods. Many computer models have been developed for Spice and for the ATP (Alternative Transients Program), modeling the several working circuits that have been developed for use in the laboratory. And finally, methods of induction of chaos in electronic circuits have been explored.« less

  7. Diagnosis of systemic lupus erythematosus in an unusual presentation: what a primary care physician should know.

    PubMed

    Pramanik, Bimalendu

    2014-01-01

    Systemic Lupus Erythematosus (SLE) is a multisystem autoimmune disease affecting millions of people worldwide. It can affect any organ systems of the body. However, all systems may not be involved initially rather than they may be affected gradually, sometimes over years. Diagnosis depends on characteristic clinical features and laboratory test results. Some features such as skin rash, joint symptoms and oral ulcers are common in SLE. But initial presentation of many patients is unusual because either they do not have these common features of the disease or the presentation mimics other illnesses. As a result, delayed diagnosis and misdiagnosis are common. Therefore, high index of initial suspicion of SLE is critical. In clinical practice, SLE should be suspected in any patient presenting with an unexplained disease process involving two or more organ systems. To make a diagnosis in an unusual presentation, thorough clinical evaluation with details history of both present and past illnesses as well as laboratory tests for SLE should be performed. Usually primary-care physicians first evaluate SLE patients; but there is no single article, where all the information on when to suspect SLE in an unusual presentation, is available in an integrated form. In this article, a list of conditions, when SLE should be suspected in an unusual presentation, has been given and some relatively common areas with diagnostic challenges of SLE have been briefly described. To prepare this manuscript, most articles have been identified through 'Pubmed' search using keywords-atypical/ unusual presentation of SLE, case reports on SLE, gastrointestinal manifestations of SLE, neuropsychiatric SLE, diagnostic challenges with SLE, etc. Selected most articles are from currently medline-indexed journals.

  8. Developmental Testing of Electric Thrust Vector Control Systems for Manned Launch Vehicle Applications

    NASA Technical Reports Server (NTRS)

    Bates, Lisa B.; Young, David T.

    2012-01-01

    This paper describes recent developmental testing to verify the integration of a developmental electromechanical actuator (EMA) with high rate lithium ion batteries and a cross platform extensible controller. Testing was performed at the Thrust Vector Control Research, Development and Qualification Laboratory at the NASA George C. Marshall Space Flight Center. Electric Thrust Vector Control (ETVC) systems like the EMA may significantly reduce recurring launch costs and complexity compared to heritage systems. Electric actuator mechanisms and control requirements across dissimilar platforms are also discussed with a focus on the similarities leveraged and differences overcome by the cross platform extensible common controller architecture.

  9. Manifestation of Central Diabetes Insipidus in a Patient with Thyroid Storm.

    PubMed

    Nakamichi, Akiko; Ocho, Kazuki; Oka, Kosuke; Yasuda, Miho; Hasegawa, Kou; Iwamuro, Masaya; Obika, Mikako; Rai, Kammei; Otsuka, Fumio

    2018-02-28

    We herein report a case of central diabetes insipidus complicated with thyroid storm. A middle-aged woman who was receiving treatment for Graves' disease suddenly complained of polydipsia, polyuria and general fatigue. Laboratory tests showed hyperthyroidism, hypernatremia, hypoosmolar urine and a decreased plasma vasopressin level. The occurrence of central diabetes insipidus with hyperthyroidism was revealed on the basis of pituitary magnetic resonance imaging, a water deprivation test and a desmopressin test. The clinical co-existence of diabetes insipidus and hyperthyroidism is very rare; however, the complication should be considered when hypernatremia and/or dehydration progress in patients with Graves's disease as a common autoimmune-related etiology.

  10. Mortality and pathology in brown bullheads Amieurus nebulosus associated with a spontaneous Edwardsiella ictaluri outbreak under tank culture conditions

    USGS Publications Warehouse

    Iwanowicz, L.R.; Griffin, A.R.; Cartwright, Deborah D.; Blazer, V.S.

    2006-01-01

    Brown bullheads Amieurus nebulosus (family Ictaluridae) are commonly used as a sentinel of environmental contamination. These fish are not generally cultured under laboratory conditions and little is known about their disease susceptibility. Here we report an outbreak of disease due to Edwardsiella ictaluri in a laboratory population of tank-reared, wild-caught brown bullheads. The isolate was positively identified as E. ictaluri using standard bacteriological substrate utilization tests and a monoclonal antibody specific for this bacterium. This pathogen causes a significant disease in channel catfish Ictalurus punctatus and is associated with disease in other ictalurid and non-ictalurid fishes. It appears that E. ictaluri is also a significant pathogen in brown bullheads and produces clinical signs and lesions similar but not identical to those observed in channel catfish. Since commercial sources of bullheads for laboratory tank studies are not available, precautions should be taken to prevent potential E. ictaluri disease outbreaks from wild-caught bullheads intended for laboratory research. ?? Inter-Research 2006.

  11. Mortality and pathology in brown bullheads Amieurus nebulosus associated with a spontaneous Edwardsiella ictaluri outbreak under tank culture conditions.

    PubMed

    Iwanowicz, Luke R; Griffin, Alison R; Cartwright, Deborah D; Blazer, Vicki S

    2006-06-23

    Brown bullheads Amieurus nebulosus (family Ictaluridae) are commonly used as a sentinel of environmental contamination. These fish are not generally cultured under laboratory conditions and little is known about their disease susceptibility. Here we report an outbreak of disease due to Edwardsiella ictaluri in a laboratory population of tank-reared, wild-caught brown bullheads. The isolate was positively identified as E. ictaluri using standard bacteriological substrate utilization tests and a monoclonal antibody specific for this bacterium. This pathogen causes a significant disease in channel catfish Ictalurus punctatus and is associated with disease in other ictalurid and non-ictalurid fishes. It appears that E. ictaluri is also a significant pathogen in brown bullheads and produces clinical signs and lesions similar but not identical to those observed in channel catfish. Since commercial sources of bullheads for laboratory tank studies are not available, precautions should be taken to prevent potential E. ictaluri disease outbreaks from wild-caught bullheads intended for laboratory research.

  12. Correlation, necessity, and sufficiency: Common errors in the scientific reasoning of undergraduate students for interpreting experiments.

    PubMed

    Coleman, Aaron B; Lam, Diane P; Soowal, Lara N

    2015-01-01

    Gaining an understanding of how science works is central to an undergraduate education in biology and biochemistry. The reasoning required to design or interpret experiments that ask specific questions does not come naturally, and is an essential part of the science process skills that must be learned for an understanding of how scientists conduct research. Gaps in these reasoning skills make it difficult for students to become proficient in reading primary scientific literature. In this study, we assessed the ability of students in an upper-division biochemistry laboratory class to use the concepts of correlation, necessity, and sufficiency in interpreting experiments presented in a format and context that is similar to what they would encounter when reading a journal article. The students were assessed before and after completion of a laboratory module where necessary vs. sufficient reasoning was used to design and interpret experiments. The assessment identified two types of errors that were commonly committed by students when interpreting experimental data. When presented with an experiment that only establishes a correlation between a potential intermediate and a known effect, students frequently interpreted the intermediate as being sufficient (causative) for the effect. Also, when presented with an experiment that tests only necessity for an intermediate, they frequently made unsupported conclusions about sufficiency, and vice versa. Completion of the laboratory module and instruction in necessary vs. sufficient reasoning showed some promise for addressing these common errors. © 2015 The International Union of Biochemistry and Molecular Biology.

  13. Comprehensive clinical approach to renal tubular acidosis.

    PubMed

    Sharma, Sonia; Gupta, Ankur; Saxena, Sanjiv

    2015-08-01

    Renal tubular acidosis (RTA) is essentially characterized by normal anion gap and hyperchloremic metabolic acidosis. It is important to understand that despite knowing the disease for 60-70 years, complexities in the laboratory tests and their interpretation still make clinicians cautious to diagnose and label types of tubular disorder. Hence, we are writing this mini-review to emphasize on the step wise approach to RTA with some understanding on its basic etiopathogenesis. This will definitely help to have an accurate interpretation of urine and blood reports in correlation with the clinical condition. RTA can be a primary or secondary defect and results either due to abnormality in bicarbonate ion absorption or hydrogen ion secretion. Primary defects are common in children due to gene mutation or idiopathic nature while secondary forms are more common in adults. We are focusing and explaining here in this review all the clinical and laboratory parameters which are essential for making the diagnosis of RTA and excluding the extrarenal causes of hyperchloremic, normal anion gap metabolic acidosis.

  14. Portable thin layer chromatography for field detection of explosives and propellants

    NASA Astrophysics Data System (ADS)

    Satcher, Joe H.; Maienschein, Jon L.; Pagoria, Philip F.; Racoveanu, Ana; Carman, M. Leslie; Whipple, Richard E.; Reynolds, John G.

    2012-06-01

    A field deployable detection kit for explosives and propellants using thin layer chromatography (TLC) has been developed at Lawrence Livermore National Laboratory (LLNL). The chemistry of the kit has been modified to allow for field detection of propellants (through propellant stabilizers), military explosives, peroxide explosives, nitrates and inorganic oxidizer precursors. For many of these target analytes, the detection limit is in the μg to pg range. A new miniaturized, bench prototype, field portable TLC (Micro TLC) kit has also been developed for the detection and identification of common military explosives. It has been demonstrated in a laboratory environment and is ready for field-testing. The kit is comprised of a low cost set of commercially available components specifically assembled for rapid identification needed in the field and identifies the common military explosives: HMX, RDX, Tetryl, Explosive D or picric acid, and TNT all on one plate. Additional modifications of the Micro TLC system have been made with fluorescent organosilicon co-polymer coatings to detect a large suite of explosives.

  15. A rigorous approach to facilitate and guarantee the correctness of the genetic testing management in human genome information systems.

    PubMed

    Araújo, Luciano V; Malkowski, Simon; Braghetto, Kelly R; Passos-Bueno, Maria R; Zatz, Mayana; Pu, Calton; Ferreira, João E

    2011-12-22

    Recent medical and biological technology advances have stimulated the development of new testing systems that have been providing huge, varied amounts of molecular and clinical data. Growing data volumes pose significant challenges for information processing systems in research centers. Additionally, the routines of genomics laboratory are typically characterized by high parallelism in testing and constant procedure changes. This paper describes a formal approach to address this challenge through the implementation of a genetic testing management system applied to human genome laboratory. We introduced the Human Genome Research Center Information System (CEGH) in Brazil, a system that is able to support constant changes in human genome testing and can provide patients updated results based on the most recent and validated genetic knowledge. Our approach uses a common repository for process planning to ensure reusability, specification, instantiation, monitoring, and execution of processes, which are defined using a relational database and rigorous control flow specifications based on process algebra (ACP). The main difference between our approach and related works is that we were able to join two important aspects: 1) process scalability achieved through relational database implementation, and 2) correctness of processes using process algebra. Furthermore, the software allows end users to define genetic testing without requiring any knowledge about business process notation or process algebra. This paper presents the CEGH information system that is a Laboratory Information Management System (LIMS) based on a formal framework to support genetic testing management for Mendelian disorder studies. We have proved the feasibility and showed usability benefits of a rigorous approach that is able to specify, validate, and perform genetic testing using easy end user interfaces.

  16. A rigorous approach to facilitate and guarantee the correctness of the genetic testing management in human genome information systems

    PubMed Central

    2011-01-01

    Background Recent medical and biological technology advances have stimulated the development of new testing systems that have been providing huge, varied amounts of molecular and clinical data. Growing data volumes pose significant challenges for information processing systems in research centers. Additionally, the routines of genomics laboratory are typically characterized by high parallelism in testing and constant procedure changes. Results This paper describes a formal approach to address this challenge through the implementation of a genetic testing management system applied to human genome laboratory. We introduced the Human Genome Research Center Information System (CEGH) in Brazil, a system that is able to support constant changes in human genome testing and can provide patients updated results based on the most recent and validated genetic knowledge. Our approach uses a common repository for process planning to ensure reusability, specification, instantiation, monitoring, and execution of processes, which are defined using a relational database and rigorous control flow specifications based on process algebra (ACP). The main difference between our approach and related works is that we were able to join two important aspects: 1) process scalability achieved through relational database implementation, and 2) correctness of processes using process algebra. Furthermore, the software allows end users to define genetic testing without requiring any knowledge about business process notation or process algebra. Conclusions This paper presents the CEGH information system that is a Laboratory Information Management System (LIMS) based on a formal framework to support genetic testing management for Mendelian disorder studies. We have proved the feasibility and showed usability benefits of a rigorous approach that is able to specify, validate, and perform genetic testing using easy end user interfaces. PMID:22369688

  17. Clonality Testing in Veterinary Medicine: A Review With Diagnostic Guidelines.

    PubMed

    Keller, S M; Vernau, W; Moore, P F

    2016-07-01

    The accurate distinction of reactive and neoplastic lymphoid proliferations can present challenges. Given the different prognoses and treatment strategies, a correct diagnosis is crucial. Molecular clonality assays assess rearranged lymphocyte antigen receptor gene diversity and can help differentiate reactive from neoplastic lymphoid proliferations. Molecular clonality assays are commonly used to assess atypical, mixed, or mature lymphoid proliferations; small tissue fragments that lack architecture; and fluid samples. In addition, clonality testing can be utilized to track neoplastic clones over time or across anatomic sites. Molecular clonality assays are not stand-alone tests but useful adjuncts that follow clinical, morphologic, and immunophenotypic assessment. Even though clonality testing provides valuable information in a variety of situations, the complexities and pitfalls of this method, as well as its dependency on the experience of the interpreter, are often understated. In addition, a lack of standardized terminology, laboratory practices, and interpretational guidelines hinders the reproducibility of clonality testing across laboratories in veterinary medicine. The objectives of this review are twofold. First, the review is intended to familiarize the diagnostic pathologist or interested clinician with the concepts, potential pitfalls, and limitations of clonality testing. Second, the review strives to provide a basis for future harmonization of clonality testing in veterinary medicine by providing diagnostic guidelines. © The Author(s) 2016.

  18. Clinical next-generation sequencing in patients with non-small cell lung cancer.

    PubMed

    Hagemann, Ian S; Devarakonda, Siddhartha; Lockwood, Christina M; Spencer, David H; Guebert, Kalin; Bredemeyer, Andrew J; Al-Kateb, Hussam; Nguyen, TuDung T; Duncavage, Eric J; Cottrell, Catherine E; Kulkarni, Shashikant; Nagarajan, Rakesh; Seibert, Karen; Baggstrom, Maria; Waqar, Saiama N; Pfeifer, John D; Morgensztern, Daniel; Govindan, Ramaswamy

    2015-02-15

    A clinical assay was implemented to perform next-generation sequencing (NGS) of genes commonly mutated in multiple cancer types. This report describes the feasibility and diagnostic yield of this assay in 381 consecutive patients with non-small cell lung cancer (NSCLC). Clinical targeted sequencing of 23 genes was performed with DNA from formalin-fixed, paraffin-embedded (FFPE) tumor tissue. The assay used Agilent SureSelect hybrid capture followed by Illumina HiSeq 2000, MiSeq, or HiSeq 2500 sequencing in a College of American Pathologists-accredited, Clinical Laboratory Improvement Amendments-certified laboratory. Single-nucleotide variants and insertion/deletion events were reported. This assay was performed before methods were developed to detect rearrangements by NGS. Two hundred nine of all requisitioned samples (55%) were successfully sequenced. The most common reason for not performing the sequencing was an insufficient quantity of tissue available in the blocks (29%). Excisional, endoscopic, and core biopsy specimens were sufficient for testing in 95%, 66%, and 40% of the cases, respectively. The median turnaround time (TAT) in the pathology laboratory was 21 days, and there was a trend of an improved TAT with more rapid sequencing platforms. Sequencing yielded a mean coverage of 1318×. Potentially actionable mutations (ie, predictive or prognostic) were identified in 46% of 209 samples and were most commonly found in KRAS (28%), epidermal growth factor receptor (14%), phosphatidylinositol-4,5-bisphosphate 3-kinase catalytic subunit alpha (4%), phosphatase and tensin homolog (1%), and BRAF (1%). Five percent of the samples had multiple actionable mutations. A targeted therapy was instituted on the basis of NGS in 11% of the sequenced patients or in 6% of all patients. NGS-based diagnostics are feasible in NSCLC and provide clinically relevant information from readily available FFPE tissue. The sample type is associated with the probability of successful testing. © 2014 American Cancer Society.

  19. Bench model surgical skill training improves novice ability to multitask: a randomized controlled study.

    PubMed

    Grierson, Lawrence; Melnyk, Megan; Jowlett, Nathan; Backstein, David; Dubrowski, Adam

    2011-01-01

    Skills training in simulation laboratories is becoming increasingly common. However, the educational benefit of these laboratories remains unclear. This study examined whether such training enables better performance on the simultaneous execution of technical skill and knowledge retention. Twenty-four novice trainees completed the elliptical excision on baseline testing. Following baseline testing twelve of the novices completed a technical practice (simulation training group) session, while the other twelve did not (control group). One week later, all participants returned for dual-task follow up testing in which they performed the excision while listening to a didactic lesson on the staging and treatment of cutaneous melanoma. The dual-tasking during the post test was standardized, whereby excision sutures 3 and 5 were performed alone (single), and sutures 4 and 6 were performed concurrently with the didactic lecture (dual). Seven additional trainees also participated as controls that were randomized to listen to the didactic lesson alone (knowledge retention alone group). Knowledge retention was assessed by a multiple choice questionnaire (MCQ). Technical performance was evaluated with computer and expert-based measures. Time to complete the performance improved among both groups completing the elliptical excision on follow-up testing (p<0.01). The simulation training group demonstrated superior hand motion performance on simultaneous didactic lesson testing (p<0.01). Novices from the no-training group performed statistically worse while suturing concurrently with the didactic lesson (p<0.01). The pretraining of novices in surgical skills laboratories leads to improved technical performance during periods of increased attention demands.

  20. Accuracy of dengue clinical diagnosis with and without NS1 antigen rapid test: Comparison between human and Bayesian network model decision.

    PubMed

    Sa-Ngamuang, Chaitawat; Haddawy, Peter; Luvira, Viravarn; Piyaphanee, Watcharapong; Iamsirithaworn, Sopon; Lawpoolsri, Saranath

    2018-06-18

    Differentiating dengue patients from other acute febrile illness patients is a great challenge among physicians. Several dengue diagnosis methods are recommended by WHO. The application of specific laboratory tests is still limited due to high cost, lack of equipment, and uncertain validity. Therefore, clinical diagnosis remains a common practice especially in resource limited settings. Bayesian networks have been shown to be a useful tool for diagnostic decision support. This study aimed to construct Bayesian network models using basic demographic, clinical, and laboratory profiles of acute febrile illness patients to diagnose dengue. Data of 397 acute undifferentiated febrile illness patients who visited the fever clinic of the Bangkok Hospital for Tropical Diseases, Thailand, were used for model construction and validation. The two best final models were selected: one with and one without NS1 rapid test result. The diagnostic accuracy of the models was compared with that of physicians on the same set of patients. The Bayesian network models provided good diagnostic accuracy of dengue infection, with ROC AUC of 0.80 and 0.75 for models with and without NS1 rapid test result, respectively. The models had approximately 80% specificity and 70% sensitivity, similar to the diagnostic accuracy of the hospital's fellows in infectious disease. Including information on NS1 rapid test improved the specificity, but reduced the sensitivity, both in model and physician diagnoses. The Bayesian network model developed in this study could be useful to assist physicians in diagnosing dengue, particularly in regions where experienced physicians and laboratory confirmation tests are limited.

  1. Uptake of recommended common reference intervals for chemical pathology in Australia.

    PubMed

    Jones, Graham Rd; Koetsier, Sabrina

    2017-05-01

    Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.

  2. An Alternative Approach for Preparing and Standardizing Some Common Aqueous Reagents Used in an Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Melaku, Samuel; Dabke, Rajeev B.

    2014-01-01

    A guide for instructors and laboratory assistants to prepare some common aqueous reagents used in an undergraduate laboratory is presented. Dilute reagents consisting of H[superscript +](aq), I[subscript 3][superscript-](aq), Ce[superscript 4+](aq), and Ag[superscript+](aq) were prepared by electrolytic oxidation of respective precursors.…

  3. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part I - rationale and aims.

    PubMed

    Davis, Bruce H; Wood, Brent; Oldaker, Teri; Barnett, David

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part I - Rationale and aims. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.

  4. Implementation of the Xpert MTB/RIF assay for tuberculosis in Mongolia: a qualitative exploration of barriers and enablers

    PubMed Central

    Bekhbat, Solongo; Ganbaatar, Gantungalag; Dorjravdan, Munkhjargal; Pai, Madhukar; Dobler, Claudia C.

    2017-01-01

    Objective The aim of our study was to identify barriers and enablers to implementation of the Xpert MTB/RIF test within Mongolia’s National Tuberculosis Program. Methods Twenty-foursemi-structured interviews were conducted between June and September 2015 with laboratory staff and tuberculosis physicians in Mongolia’s capital Ulaanbaatar and regional towns where Xpert MTB/RIF testing had been implemented. Interviews were recorded, transcribed, translated and analysed thematically using NVIVO qualitative analysis software. Results Eight laboratory staff (five from the National Tuberculosis Reference Laboratory in Ulaanbaatar and three from provincial laboratories) and sixteen tuberculosis physicians (five from the Mongolian National Center for Communicable Diseases in Ulaanbaatar, four from district tuberculosis clinics in Ulaanbaatar and seven from provincial tuberculosis clinics) were interviewed. Major barriers to Xpert MTB/RIF implementation identified were: lack of awareness of program guidelines; inadequate staffing arrangements; problems with cartridge supply management; lack of local repair options for the Xpert machines; lack of regular formal training; paper based system; delayed treatment initiation due to consensus meeting and poor sample quality. Enablers to Xpert MTB/RIF implementation included availability of guidelines in the local language; provision of extra laboratory staff, shift working arrangements and additional modules; capacity for troubleshooting internally; access to experts; opportunities for peer learning; common understanding of diagnostic algorithms and decentralised testing. Conclusion Our study identified a number of barriers and enablers to implementation of Xpert MTB/RIF in the Mongolian National Tuberculosis Program. Lessons learned from this study can help to facilitate implementation of Xpert MTB/RIF in other Mongolian locations as well as other low-and middle-income countries. PMID:28717600

  5. [Medical supports for the diagnosis of infectious diseases; the role and responsibilities of clinical pathologist and microbiology technologist. Acute purulent meningitis; the position of the technologists in microbiology laboratory].

    PubMed

    Misawa, Shigeki

    2002-07-01

    The features and limitations of microbiology processes for the diagnosis of bacterial meningitis were summarized. Requests for physicians were also emphasized. The microbiology laboratory should be responsible for providing highly reliable and concordant data with a variety of clinical settings. Technologists in a microbiology laboratory should perform following subjects: i) Direct smear examination: Presumptive identification by the observers with abundant experience and sufficient training. ii) Rapid bacterial antigen detection tests: Active utilize alone in combination with the direct microscopy. iii) Culture: Cost effective utilize for appropriate media and culture condition based on the bacteriological statistics. Report with bacteriological interpretations and with additional proper comments, if necessary. iv) Antimicrobial susceptibility tests: Determination of penicillin resistance among the strains of penicillin-resistant or-intermediate Streptococcus pneumoniae (PI or PRSP) should be confirmed by MIC procedures; Detection of beta-lactamase producing Haemophilus influenzae (BLP) could detect by beta-lactamase tests, but not clearly identify for beta-lactamase-negative ampicillin-resistant isolates (BLNAR). In addition, a laboratory should provide appropriate information by using the accumulated routine clinical microbiology data, which may help to physicians in selecting an empiric therapy and to the microbiology technologists in processing the routine microbiology. In recent status, the most common organisms isolated from patients with bacterial meningitis continue to be S. pneumoniae and H. influenzae. Among S. pneumoniae strains, penicillin-intermediate(PISP) and--resistant(PRSP) strains had exceeded 50%, and the strains of beta-lactamase producing H. influenzae (BLP) had decreased with less than 10% and beta-lactamase negative ampicillin-resistant strains (BLNAR) have increasing. To providing rapid and accurate results, a laboratory should require the clinical information, including patient's age, major presenting symptoms, and receive antimicrobials prior to specimen collection.

  6. FELASA recommendations for the health monitoring of mouse, rat, hamster, guinea pig and rabbit colonies in breeding and experimental units.

    PubMed

    Mähler Convenor, M; Berard, M; Feinstein, R; Gallagher, A; Illgen-Wilcke, B; Pritchett-Corning, K; Raspa, M

    2014-07-01

    The microbiological quality of experimental animals can critically influence animal welfare and the validity and reproducibility of research data. It is therefore important for breeding and experimental facilities to establish a laboratory animal health monitoring (HM) programme as an integrated part of any quality assurance system. FELASA has published recommendations for the HM of rodent and rabbit colonies in breeding and experimental units (Nicklas et al. Laboratory Animals, 2002), with the intention of harmonizing HM programmes. As stated in the preamble, these recommendations need to be adapted periodically to meet current developments in laboratory animal medicine. Accordingly, previous recommendations have been revised and shall be replaced by the present recommendations. These recommendations are aimed at all breeders and users of laboratory mice, rats, Syrian hamsters, guinea pigs and rabbits as well as diagnostic laboratories. They describe essential aspects of HM, such as the choice of agents, selection of animals and tissues for testing, frequency of sampling, commonly used test methods, interpretation of results and HM reporting. Compared with previous recommendations, more emphasis is put on the role of a person with sufficient understanding of the principles of HM, opportunistic agents, the use of sentinel animals (particularly under conditions of cage-level containment) and the interpretation and reporting of HM results. Relevant agents, testing frequencies and literature references are updated. Supplementary information on specific agents and the number of animals to be monitored and an example of a HM programme description is provided in the appendices. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Task-shifting point-of-care CD4+ testing to lay health workers in HIV care and treatment services in Namibia.

    PubMed

    Kaindjee-Tjituka, Francina; Sawadogo, Souleymane; Mutandi, Graham; Maher, Andrew D; Salomo, Natanael; Mbapaha, Claudia; Neo, Marytha; Beukes, Anita; Gweshe, Justice; Muadinohamba, Alexinah; Lowrance, David W

    2017-01-01

    Access to CD4+ testing remains a common barrier to early initiation of antiretroviral therapy among persons living with HIV/AIDS in low- and middle-income countries. The feasibility of task-shifting of point-of-care (POC) CD4+ testing to lay health workers in Namibia has not been evaluated. From July to August 2011, Pima CD4+ analysers were used to improve access to CD4+ testing at 10 selected public health facilities in Namibia. POC Pima CD4+ testing was performed by nurses or lay health workers. Venous blood samples were collected from 10% of patients and sent to centralised laboratories for CD4+ testing with standard methods. Outcomes for POC Pima CD4+ testing and patient receipt of results were compared between nurses and lay health workers and between the POC method and standard laboratory CD4+ testing methods. Overall, 1429 patients received a Pima CD4+ test; 500 (35.0%) tests were performed by nurses and 929 (65.0%) were performed by lay health workers. When Pima CD4+ testing was performed by a nurse or a lay health worker, 93.2% and 95.2% of results were valid ( p = 0.1); 95.6% and 98.1% of results were received by the patient ( p = 0.007); 96.2% and 94.0% of results were received by the patient on the same day ( p = 0.08). Overall, 97.2% of Pima CD4+ results were received by patients, compared to 55.4% of standard laboratory CD4+ results ( p < 0.001). POC CD4+ testing was feasible and effective when task-shifted to lay health workers. Rollout of POC CD4+ testing via task-shifting can improve access to CD4+ testing and retention in care between HIV diagnosis and antiretroviral therapy initiation in low- and middle-income countries.

  8. Preferred mirror coatings for UV, visible, and IR space optical instruments

    NASA Astrophysics Data System (ADS)

    Heaney, James B.; Kauder, Lonny R.; Freese, Scott C.; Quijada, Manuel A.

    2012-09-01

    This paper will review the suitability of the common four types of reflecting surfaces - Ag, Al, Au and Be - for use aboard satellite borne remote sensing and astrophysical observatories, from the uv to far-ir spectral bands. The choice of appropriate protecting and reflectance enhancing overcoats for these reflecting metals will be discussed. Laboratory test data and optical diagnostic techniques used to verify durability of the selected coatings in a terrestrial storage environment and their sensitivity to a space radiation and cold temperature environment will be presented. For some of the selected coatings, a connection will be made between pre-launch laboratory quality checks and post-launch performance on orbit.

  9. Artificial intelligence models for predicting iron deficiency anemia and iron serum level based on accessible laboratory data.

    PubMed

    Azarkhish, Iman; Raoufy, Mohammad Reza; Gharibzadeh, Shahriar

    2012-06-01

    Iron deficiency anemia (IDA) is the most common nutritional deficiency worldwide. Measuring serum iron is time consuming, expensive and not available in most hospitals. In this study, based on four accessible laboratory data (MCV, MCH, MCHC, Hb/RBC), we developed an artificial neural network (ANN) and an adaptive neuro-fuzzy inference system (ANFIS) to diagnose the IDA and to predict serum iron level. Our results represent that the neural network analysis is superior to ANFIS and logistic regression models in diagnosing IDA. Moreover, the results show that the ANN is likely to provide an accurate test for predicting serum iron levels with high accuracy and acceptable precision.

  10. Non-intrusive Shock Measurements Using Laser Doppler Vibrometers

    NASA Technical Reports Server (NTRS)

    Statham, Shannon M.; Kolaini, Ali R.

    2012-01-01

    Stud mount accelerometers are widely used by the aerospace industry to measure shock environments during hardware qualification. The commonly used contact-based sensors, however, interfere with the shock waves and distort the acquired signature, which is a concern not actively discussed in the community. To alleviate these interference issues, engineers at the Jet Propulsion Laboratory are investigating the use of non-intrusive sensors, specifically Laser Doppler Vibrometers, as alternatives to the stud mounted accelerometers. This paper will describe shock simulation tests completed at the Jet Propulsion Laboratory, compare the measurements from stud mounted accelerometers and Laser Doppler Vibrometers, and discuss the advantages and disadvantages of introducing Laser Doppler Vibrometers as alternative sensors for measuring shock environments.

  11. Genetic Misdiagnoses and the Potential for Health Disparities.

    PubMed

    Manrai, Arjun K; Funke, Birgit H; Rehm, Heidi L; Olesen, Morten S; Maron, Bradley A; Szolovits, Peter; Margulies, David M; Loscalzo, Joseph; Kohane, Isaac S

    2016-08-18

    For more than a decade, risk stratification for hypertrophic cardiomyopathy has been enhanced by targeted genetic testing. Using sequencing results, clinicians routinely assess the risk of hypertrophic cardiomyopathy in a patient's relatives and diagnose the condition in patients who have ambiguous clinical presentations. However, the benefits of genetic testing come with the risk that variants may be misclassified. Using publicly accessible exome data, we identified variants that have previously been considered causal in hypertrophic cardiomyopathy and that are overrepresented in the general population. We studied these variants in diverse populations and reevaluated their initial ascertainments in the medical literature. We reviewed patient records at a leading genetic-testing laboratory for occurrences of these variants during the near-decade-long history of the laboratory. Multiple patients, all of whom were of African or unspecified ancestry, received positive reports, with variants misclassified as pathogenic on the basis of the understanding at the time of testing. Subsequently, all reported variants were recategorized as benign. The mutations that were most common in the general population were significantly more common among black Americans than among white Americans (P<0.001). Simulations showed that the inclusion of even small numbers of black Americans in control cohorts probably would have prevented these misclassifications. We identified methodologic shortcomings that contributed to these errors in the medical literature. The misclassification of benign variants as pathogenic that we found in our study shows the need for sequencing the genomes of diverse populations, both in asymptomatic controls and the tested patient population. These results expand on current guidelines, which recommend the use of ancestry-matched controls to interpret variants. As additional populations of different ancestry backgrounds are sequenced, we expect variant reclassifications to increase, particularly for ancestry groups that have historically been less well studied. (Funded by the National Institutes of Health.).

  12. Optimal Sensor Scheduling for Multiple Hypothesis Testing

    DTIC Science & Technology

    1981-09-01

    Naval Research, under contract N00014-77-0532 is gratpfully acknowledged. 2 Laboratory for Information and Decision Systems , MIT Room 35-213, Cambridge...treat the more general problem [9,10]. However, two common threads connect these approaches: they obtain feedback laws mapping posterior destributions ...objective of a detection or identification algorithm is to produce correct estimates of the true state of a system . It is also bene- ficial if these

  13. A Systematic Experimental Test of the Ideal Gas Equation for the General Chemistry Laboratory

    NASA Astrophysics Data System (ADS)

    Blanco, Luis H.; Romero, Carmen M.

    1995-10-01

    A set of experiments that examines each one of the terms of the ideal gas equation is described. Boyle's Law, Charles-Gay Lussac's Law, Amonton's Law, the number of moles or Molecular Weight, and the Gas Constant are studied. The experiments use very simple, easy to obtain equipment and common gases, mainly air. The results gathered by General Chemistry College students are satisfactory.

  14. When Gender Identity Doesn't Equal Sex Recorded at Birth: The Role of the Laboratory in Providing Effective Healthcare to the Transgender Community.

    PubMed

    Goldstein, Zil; Corneil, Trevor A; Greene, Dina N

    2017-08-01

    Transgender is an umbrella term used to describe individuals who identify with a gender incongruent to or variant from their sex recorded at birth. Affirming gender identity through a variety of social, medical, and surgical interventions is critical to the mental health of transgender individuals. In recent years, awareness surrounding transgender identities has increased, which has highlighted the health disparities that parallel this demographic. These disparities are reflected in the experience of transgender patients and their providers when seeking clinical laboratory services. Little is known about the effect of gender-affirming hormone therapy and surgery on optimal laboratory test interpretation. Efforts to diminish health disparities encountered by transgender individuals and their providers can be accomplished by increasing social and clinical awareness regarding sex/gender incongruence and gaining insight into the physiological manifestations and laboratory interpretations of gender-affirming strategies. This review summarizes knowledge required to understand transgender healthcare including current clinical interventions for gender dysphoria. Particular attention is paid to the subsequent impact of these interventions on laboratory test utilization and interpretation. Common nomenclature and system barriers are also discussed. Understanding gender incongruence, the clinical changes associated with gender transition, and systemic barriers that maintain a gender/sex binary are key to providing adequate healthcare to transgender community. Transgender appropriate reference interval studies are virtually absent within the medical literature and should be explored. The laboratory has an important role in improving the physiological understanding, electronic medical system recognition, and overall social awareness of the transgender community. © 2017 American Association for Clinical Chemistry.

  15. Live births achieved via IVF are increased by improvements in air quality and laboratory environment.

    PubMed

    Heitmann, Ryan J; Hill, Micah J; James, Aidita N; Schimmel, Tim; Segars, James H; Csokmay, John M; Cohen, Jacques; Payson, Mark D

    2015-09-01

    Infertility is a common disease, which causes many couples to seek treatment with assisted reproduction techniques. Many factors contribute to successful assisted reproduction technique outcomes. One important factor is laboratory environment and air quality. Our facility had the unique opportunity to compare consecutively used, but separate assisted reproduction technique laboratories, as a result of a required move. Environmental conditions were improved by strategic engineering designs. All other aspects of the IVF laboratory, including equipment, physicians, embryologists, nursing staff and protocols, were kept constant between facilities. Air quality testing showed improved air quality at the new IVF site. Embryo implantation (32.4% versus 24.3%; P < 0.01) and live birth (39.3% versus 31.8%, P < 0.05) were significantly increased in the new facility compared with the old facility. More patients met clinical criteria and underwent mandatory single embryo transfer on day 5 leading to both a reduction in multiple gestation pregnancies and increased numbers of vitrified embryos per patient with supernumerary embryos available. Improvements in IVF laboratory conditions and air quality had profound positive effects on laboratory measures and patient outcomes. This study further strengthens the importance of the laboratory environment and air quality in the success of an IVF programme. Published by Elsevier Ltd.

  16. Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security

    DOE PAGES

    West, David L.; Wood, Nathan L.; Forrester, Christina D.

    2017-12-01

    This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less

  17. Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, David L.; Wood, Nathan L.; Forrester, Christina D.

    This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less

  18. Monitoring of anticoagulant therapy in heart disease: considerations for the current assays.

    PubMed

    Boroumand, Mohammadali; Goodarzynejad, Hamidreza

    2010-01-01

    Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to "normalize" all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation, and congenital factor deficiencies. In contrast to marked progress in the standardization of PT reagents for INR reporting, no standardization system has been globally adopted for standardization of PTT reagents. Recently College of American Pathologists recommend that individual laboratories establish their own therapeutic range by using aPTT values calibrated against accepted therapeutic unfractionated heparin (UFH) levels calibrated against accepted therapeutic UFH levels performing anti-Xa test (which is the most accurate assay for monitoring UFH therapy).Herein, we review recent data on the monitoring of conventional anticoagulant agents. Marked interlaboratory variability still exists for PT, INR, and PTT tests. Further research should be focused on improving the standardization and calibration of these assays.

  19. Ebola Preparedness: Diagnosis Improvement Using Rapid Approaches for Proficiency Testing.

    PubMed

    Lau, Katherine A; Theis, Torsten; Gray, Joanna; Rawlinson, William D

    2017-03-01

    The unprecedented 2015 Ebolavirus (EBOV) outbreak in West Africa was declared a public health emergency, making diagnosis and quality of testing a global issue. The accuracy of laboratory diagnostic capacity for EBOV was assessed in 2014 to 2016 using a proficiency testing (PT) strategy developed by the Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) in Biosecurity. Following a literature search, EBOV-specific gene targets were ranked according to the frequency of their use in published methods. The most commonly used gene regions (nucleoprotein [NP], glycoprotein [GP], and RNA-dependent RNA polymerase [L]) were selected for the design of in vitro RNA transcripts to be included in the simulated EBOV specimens used for EBOV detection with PCR-based assays. Specimens were tested for stability and found to be stable on long-term storage (1 year) at -80°C and on shorter-term storage in lyophilized form (1 week at ambient temperature and a subsequent week at -80°C). These specimens were used in three EBOV PTs offered from April 2014 to March 2016. In the first and third PTs, all laboratories (3/3 and 9/9, respectively) correctly identified specimens containing EBOV RNA transcripts, while in the second PT, all but one laboratory (5/6) correctly confirmed the presence of EBOV. The EBOV PT panel was useful for ensuring the competency of laboratories in detecting EBOV in the absence of readily available clinical samples. The simulated EBOV specimen was safe, stable, and reliable and can be used in lyophilized form for future EBOV PT programs, allowing simplicity of transport. Copyright © 2017 American Society for Microbiology.

  20. Using Laboratory Test Results at Hospital Admission to Predict Short-term Survival in Critically Ill Patients With Metastatic or Advanced Cancer.

    PubMed

    Cheng, Lee; DeJesus, Alma Y; Rodriguez, Maria A

    2017-04-01

    Accurately estimating the life expectancy of critically ill patients with metastatic or advanced cancer is a crucial step in planning appropriate palliative or supportive care. We evaluated the results of laboratory tests performed within two days of hospital admission to predict the likelihood of death within 14 days. We retrospectively selected patients 18 years or older with metastatic or advanced cancer who were admitted to intensive care units or palliative and supportive care services in our hospital. We evaluated whether the following are independent predictors in a logistic regression model: age, sex, comorbidities, and the results of seven commonly available laboratory tests. The end point was death within 14 days in or out of the hospital. Of 901 patients in the development cohort and 45% died within 14 days. The risk of death within 14 days after admission increased with increasing age, lactate dehydrogenase levels, and white blood cell counts and decreasing albumin levels and platelet counts (P < 0.01). The model predictions were confirmed using a separate validation cohort. The areas under the receiver operating characteristic curves were 0.74 and 0.70 for the development and validation cohorts, respectively, indicating good discriminatory ability for the model. Our results suggest that laboratory test results performed within two days of admission are valuable in predicting death within 14 days for patients with metastatic or advanced cancer. Such results may provide an objective assessment tool for physicians and help them initiate conversations with patients and families about end-of-life care. Copyright © 2017 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  1. Assessment of Accuracy of Identification of Pathogenic Yeasts in Microbiology Laboratories in the United Kingdom

    PubMed Central

    Szekely, Adrien; Palmer, Michael D.; Johnson, Elizabeth M.

    2012-01-01

    Rapid, accurate identification of yeast isolates from clinical samples has always been important given their innately variable antifungal susceptibility profiles. Recently, this has become paramount with the proposed introduction of species-specific interpretive breakpoints for MICs obtained in yeast antifungal susceptibility tests (M. A. Pfaller, D. Andes, D. J. Diekema, A. Espinel–Ingroff, D. Sheehan, and CLSI Subcommittee for Antifungal Susceptibility Testing, Drug Resist. Updat. 13:180–195, 2010). Here, we present the results of a 12-month evaluation of the accuracy of identifications that accompany yeast isolates submitted to the Mycology Reference Laboratory (United Kingdom) for either confirmation of identity or susceptibility testing. In total, 1,781 yeast isolates were analyzed, and the robustness of prior identifications obtained in microbiology laboratories throughout the United Kingdom was assessed using a combination of culture on chromogenic agar, morphology on cornmeal agar, and molecular identification by pyrosequencing. Over 40% of isolates (755) were submitted without any suggested identification. Of those isolates with a prior identification, 100 (9.7%) were incorrectly identified. Error rates ranged from 5.2% (for organisms submitted for antifungal susceptibility testing) to 18.2% (for organisms requiring confirmation of identity) and varied in a strictly species-specific manner. At least 50% of identification errors would be likely to affect interpretation of MIC data, with a possible impact on patient management. In addition, 2.3% of submitted cultures were found to contain mixtures of at least two yeast species. The vast majority of mixtures had gone undetected in the referring laboratory and would have impacted the interpretation of antifungal susceptibility profiles and patient management. Some of the more common misidentifications are discussed according to the identification method employed, with suggestions for avoiding such misinterpretations. PMID:22649009

  2. Assessment of accuracy of identification of pathogenic yeasts in microbiology laboratories in the United kingdom.

    PubMed

    Borman, Andrew M; Szekely, Adrien; Palmer, Michael D; Johnson, Elizabeth M

    2012-08-01

    Rapid, accurate identification of yeast isolates from clinical samples has always been important given their innately variable antifungal susceptibility profiles. Recently, this has become paramount with the proposed introduction of species-specific interpretive breakpoints for MICs obtained in yeast antifungal susceptibility tests (M. A. Pfaller, D. Andes, D. J. Diekema, A. Espinel-Ingroff, D. Sheehan, and CLSI Subcommittee for Antifungal Susceptibility Testing, Drug Resist. Updat. 13:180-195, 2010). Here, we present the results of a 12-month evaluation of the accuracy of identifications that accompany yeast isolates submitted to the Mycology Reference Laboratory (United Kingdom) for either confirmation of identity or susceptibility testing. In total, 1,781 yeast isolates were analyzed, and the robustness of prior identifications obtained in microbiology laboratories throughout the United Kingdom was assessed using a combination of culture on chromogenic agar, morphology on cornmeal agar, and molecular identification by pyrosequencing. Over 40% of isolates (755) were submitted without any suggested identification. Of those isolates with a prior identification, 100 (9.7%) were incorrectly identified. Error rates ranged from 5.2% (for organisms submitted for antifungal susceptibility testing) to 18.2% (for organisms requiring confirmation of identity) and varied in a strictly species-specific manner. At least 50% of identification errors would be likely to affect interpretation of MIC data, with a possible impact on patient management. In addition, 2.3% of submitted cultures were found to contain mixtures of at least two yeast species. The vast majority of mixtures had gone undetected in the referring laboratory and would have impacted the interpretation of antifungal susceptibility profiles and patient management. Some of the more common misidentifications are discussed according to the identification method employed, with suggestions for avoiding such misinterpretations.

  3. High frequency of discordance between antimüllerian hormone and follicle-stimulating hormone levels in serum from estradiol-confirmed days 2 to 4 of the menstrual cycle from 5,354 women in U.S. fertility centers.

    PubMed

    Leader, Benjamin; Hegde, Aparna; Baca, Quentin; Stone, Kimberly; Lannon, Benjamin; Seifer, David B; Broekmans, Frank; Baker, Valerie L

    2012-10-01

    To determine the frequency of clinical discordance between antimüllerian hormone (AMH, ng/mL) and follicle-stimulating hormone (FSH, IU/L) by use of cut points defined by response to controlled ovarian stimulation in the same serum samples drawn on estradiol-confirmed, menstrual cycle days 2 to 4. Retrospective analysis. Fertility centers in 30 U.S. states and a single reference laboratory with uniform testing protocols. 5,354 women, 20 to 45 years of age. None. Frequency of discordance between serum AMH and FSH values. Of the 5,354 women tested, 1 in 5 had discordant AMH and FSH values defined as AMH <0.8 (concerning) with FSH <10 (reassuring) or AMH ≥ 0.8 (reassuring) with FSH ≥ 10 (concerning). Of the women with reassuring FSH values (n = 4,469), the concerning AMH values were found in 1 in 5 women in a highly age-dependent fashion, ranging from 1 in 11 women under 35 years of age to 1 in 3 women above 40 years of age. On the other hand, of the women with reassuring AMH values (n = 3,742), 1 in 18 had concerning FSH values, a frequency that did not vary in a statistically significant fashion by age. Clinical discordance in serum AMH and FSH values was frequent and age dependent using common clinical cut points, a large patient population, one reference laboratory, and uniform testing methodology. This conclusion is generalizable to women undergoing fertility evaluation, although AMH testing has not been standardized among laboratories, and the cut points presented are specific to the laboratory in this study. Copyright © 2012. Published by Elsevier Inc.

  4. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    NASA Astrophysics Data System (ADS)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  5. Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.

    PubMed

    Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon

    2016-01-01

    Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.

  6. Studying epigenetic DNA modifications in undergraduate laboratories using complementary bioinformatic and molecular approaches.

    PubMed

    Militello, Kevin T

    2013-01-01

    Epigenetic inheritance is the inheritance of genetic information that is not based on DNA sequence alone. One type of epigenetic information that has come to the forefront in the last few years is modified DNA bases. The most common modified DNA base in nature is 5-methylcytosine. Herein, we describe a laboratory experiment that combines bioinformatic and molecular approaches to study the presence and abundance of 5-methylcytosine in different organisms. Students were originally provided with the protein sequence of the Xenopus laevis DNMT1 cytosine-5 DNA methyltransferase and used BLASTP searches to detect the presence of protein orthologs in the genomes of several organisms including Homo sapiens, Mus musculus, Plasmodium falciparum, Drosophila melanogaster, Saccharomyces cerevisiae, Arabidopsis thaliana, and Caenorhabditis elegans. Students generated hypotheses regarding the presence and abundance of 5-methylcytosine in these organisms based on their bioinformatics data, and directly tested their predictions on a subset of DNAs using restriction enzyme isoschizomer assays. A southern blotting assay to answer the same question is also presented. In addition to exposure to the field of epigenetics, the strengths of the laboratory are students are able to make predictions using bioinformatic tools and quickly test them in the laboratory. In addition, students are exposed to two potential misinterpretations of bioinformatic search data. The laboratory is easily modified to incorporate outside research interests in epigenetics. © 2013 by The International Union of Biochemistry and Molecular Biology.

  7. Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    PubMed

    Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff

    2015-01-01

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  8. Development of a multiplex serological assay reveals a worldwide distribution of murine astrovirus infections in laboratory mice.

    PubMed

    Schmidt, Katja; Butt, Julia; Mauter, Petra; Vogel, Klaus; Erles-Kemna, Andrea; Pawlita, Michael; Nicklas, Werner

    2017-01-01

    Laboratory mice play a tremendous role in biomedical research in studies on immunology, infection, cancer and therapy. In the course of standardization of mice used in animal experiments, health monitoring constitutes an important instrument towards microbiological standardization. Infections with murine astroviruses (MuAstV) were only recently discovered and are, therefore, still relatively unknown in laboratory animal science. In rodent health monitoring viral infections within a population are commonly assessed in terms of specific antibodies by serological testing, as active infection and excretion of virus is often temporary and can easily be missed. So far only ongoing infections with astroviruses can be detected by PCR. The objective of this work was the development of a sensitive and specific MuAstV multiplex serological assay with a high-throughput capability to be used in routine testing of laboratory mice. Four different MuAstV proteins were recombinantly expressed and used as antigens. The best reacting antigen, the capsid spike protein VP27, was selected and tested with a panel of 400 sera of mice from units with a known MuAstV status. Assay sensitivity and specificity resulted in 98.5% and 100%, respectively, compared to RT-PCR results. Eventually this assay was used to test 5529 serum samples in total, during routine diagnostics at the German Cancer Research Center (DKFZ) in Heidelberg between 2015 and 2017. High sero-prevalence rates of up to 98% were detected in units with open cages indicating that the virus is highly infectious and circulates within these populations virtually infecting all animals regardless of the mouse strain. In addition, data collected from 312 mice purchased from commercial breeders and from 661 mice from 58 research institutes in 15 countries worldwide allowed the conclusion that MuAstV is widespread in contemporary laboratory mouse populations.

  9. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.

  10. Point-of-care testing of electrolytes and calcium using blood gas analysers: it is time we trusted the results.

    PubMed

    Mirzazadeh, Mehdi; Morovat, Alireza; James, Tim; Smith, Ian; Kirby, Justin; Shine, Brian

    2016-03-01

    Point-of-care testing allows rapid analysis of samples to facilitate prompt clinical decisions. Electrolyte and calcium abnormalities are common in acutely ill patients and can be associated with life-threatening consequences. There is uncertainty whether clinical decisions can be based on the results obtained from blood gas analysers or if laboratory results should be awaited. To assess the agreement between sodium, potassium and calcium results from blood gas and laboratory mainstream analysers in a tertiary centre, with a network consisting of one referral and two peripheral hospitals, consisting of three networked clinical biochemistry laboratories. Using the laboratory information management system database and over 11 000 paired samples in three hospital sites, the results of sodium, potassium and ionised calcium on blood gas analysers were studied over a 5-year period and compared with the corresponding laboratory results from the same patients booked in the laboratory within 1 h. The Pearson's linear correlation coefficient between laboratory and blood gas results for sodium, potassium and calcium were 0.92, 0.84 and 0.78, respectively. Deming regression analysis showed a slope of 1.04 and an intercept of -5.7 for sodium, slope of 0.93 and an intercept of 0.22 for potassium and a slope of 1.23 with an intercept of -0.55 for calcium. With some strict statistical assumptions, percentages of results lying outside the least significant difference were 9%, 26.7% and 20.8% for sodium, potassium and calcium, respectively. Most clinicians wait for the laboratory confirmation of results generated by blood gas analysers. In a large retrospective study we have shown that there is sufficient agreement between the results obtained from the blood gas and laboratory analysers to enable prompt clinical decisions to be made. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    PubMed

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely dependent on manual paper-based processes to monitor immunosuppression for post-liver transplant patients. Similar immunosuppression guidelines provide opportunities for sharing CDS once integrated laboratory data are available.

  12. Load Disaggregation Technologies: Real World and Laboratory Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.

    Low cost interval metering and communication technology improvements over the past ten years have enabled the maturity of load disaggregation (or non-intrusive load monitoring) technologies to better estimate and report energy consumption of individual end-use loads. With the appropriate performance characteristics, these technologies have the potential to enable many utility and customer facing applications such as billing transparency, itemized demand and energy consumption, appliance diagnostics, commissioning, energy efficiency savings verification, load shape research, and demand response measurement. However, there has been much skepticism concerning the ability of load disaggregation products to accurately identify and estimate energy consumption of end-uses; whichmore » has hindered wide-spread market adoption. A contributing factor is that common test methods and metrics are not available to evaluate performance without having to perform large scale field demonstrations and pilots, which can be costly when developing such products. Without common and cost-effective methods of evaluation, more developed disaggregation technologies will continue to be slow to market and potential users will remain uncertain about their capabilities. This paper reviews recent field studies and laboratory tests of disaggregation technologies. Several factors are identified that are important to consider in test protocols, so that the results reflect real world performance. Potential metrics are examined to highlight their effectiveness in quantifying disaggregation performance. This analysis is then used to suggest performance metrics that are meaningful and of value to potential users and that will enable researchers/developers to identify beneficial ways to improve their technologies.« less

  13. Differentiation between intra-abdominal neoplasms and abscesses in horses, using clinical and laboratory data: 40 cases (1973-1988).

    PubMed

    Zicker, S C; Wilson, W D; Medearis, I

    1990-04-01

    The medical records of 25 horses with intra-abdominal neoplasms and 15 horses with intra-abdominal abscesses were reviewed. Common clinical signs of disease observed by owners of horses in both groups included anorexia, weight loss, fever, signs of colic, and depression. Clinical laboratory abnormalities included leukocytosis, hyperfibrinogenemia, hypoalbuminemia, and hypocalcemia. There was considerable overlap of laboratory test results within and between the 2 groups of horses. Peritoneal fluid was classified as an exudate in 12 of 15 horses with intra-abdominal abscesses and in 14 of 25 horses with intra-abdominal neoplasms. Cytologic examination of peritoneal fluid yielded an accurate diagnosis in 11 of 25 horses with neoplasia and in 3 of 15 horses with abscesses. A mean number of 1.45 cytologic analyses/horse was needed to diagnose neoplasms in the 11 horses in which the analysis was successful in definitively diagnosing the condition.

  14. Infrastructure for Personalized Medicine at Partners HealthCare

    PubMed Central

    Weiss, Scott T.; Shin, Meini Sumbada

    2016-01-01

    Partners HealthCare Personalized Medicine (PPM) is a center within the Partners HealthCare system (founded by Massachusetts General Hospital and Brigham and Women’s Hospital) whose mission is to utilize genetics and genomics to improve the care of patients in a cost effective manner. PPM consists of five interconnected components: (1) Laboratory for Molecular Medicine (LMM), a CLIA laboratory performing genetic testing for patients world-wide; (2) Translational Genomics Core (TGC), a core laboratory providing genomic platforms for Partners investigators; (3) Partners Biobank, a biobank of samples (DNA, plasma and serum) for 50,000 Consented Partners patients; (4) Biobank Portal, an IT infrastructure and viewer to bring together genotypes, samples, phenotypes (validated diagnoses, radiology, and clinical chemistry) from the electronic medical record to Partners investigators. These components are united by (5) a common IT system that brings researchers, clinicians, and patients together for optimal research and patient care. PMID:26927187

  15. Evaluation of Mysidopsis bahia fecundity endpoint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griffin, D.; Wahl, E.; Krause, P.R.

    1995-12-31

    The M. bahia chronic toxicity test is commonly used to test estuarine and marine effluent discharges. The test evaluates three endpoints: survival, growth, and fecundity. The fecundity endpoint is often erratic over time and does not necessarily predict accurately other endpoints of effluent toxicity. Therefore, an analysis of the fecundity endpoint was performed to evaluate its use in compliance testing. The endpoint analysis was conducted in three phases: a literature search, analysis of M. bahia data from 24 separate testing events, and interviews with various policy makers, statisticians, and biologists. The literature search revealed a dozen publications, none of whichmore » evaluated fecundity using the EPA method. The literature suggested that evaluating fecundity was labor-intensive and inadequate for practical compliance testing applications. Analysis of the 24 tests revealed that fecundity was evaluated only half of the time (i.e. when at least 50% of the females in the control were fecund). There was a high coefficient of variation (C.V.) between replicates for fecundity (range = 9.--1209.3,x = 85.2%) as compared to survival (range = 0.0--24.0,x = 13.7 %) and growth (range = 7.5--43.9,x = 19.1%). The fecundity results were erratic and did not always follow a dose-response curve, due in part to the small sample size per replicate. Interviews showed that the fecundity endpoint was being evaluated differently by different laboratories. Some were using fecundity for compliance while others were not. Most people interviewed recognized there were inconsistencies with the endpoint. The conclusions drawn from the evaluation were that (1) fecundity does not lend itself for use as a compliance endpoint, (2) the fecundity evaluation process is time consuming and labor intensive, and (3) interpretation of the results is not consistent from laboratory to laboratory and from region to region.« less

  16. The Grass Isn’t Always Greener: Perceptions of and Performance on Open-Note Exams

    PubMed Central

    Sato, Brian K.; He, Wenliang; Warschauer, Mark; Kadandale, Pavan

    2015-01-01

    Undergraduate biology education is often viewed as being focused on memorization rather than development of students’ critical-thinking abilities. We speculated that open-note testing would be an easily implemented change that would emphasize higher-order thinking. As open-note testing is not commonly used in the biological sciences and the literature on its effects in biology education is sparse, we performed a comprehensive analysis of this intervention on a primary literature–based exam across three large-enrollment laboratory courses. Although students believed open-note testing would impact exam scores, we found no effect on performance, either overall or on questions of nearly all Bloom’s levels. Open-note testing also produced no advantage when examined under a variety of parameters, including research experience, grade point average, course grade, prior exposure to primary literature–focused laboratory courses, or gender. Interestingly, we did observe small differences in open- and closed-note exam performance and perception for students who experienced open-note exams for an entire quarter. This implies that student preparation or in-test behavior can be altered by exposure to open-note testing conditions in a single course and that ­increased experience may be necessary to truly understand the impact of this intervention. PMID:25828402

  17. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    PubMed

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  18. Finite Source Inversion for Laboratory Earthquakes

    NASA Astrophysics Data System (ADS)

    Parker, J. M.; Glaser, S. D.

    2017-12-01

    We produce finite source inversion results for laboratory earthquakes (LEQ) in PMMA confirmed by video recording of the fault contact. The LEQs are generated under highly controlled laboratory conditions and recorded by an array of absolutely calibrated acoustic emissions (AE) sensors. Following the method of Hartzell and Heaton (1983), we develop a solution using only the single-component AE sensors common in laboratory experiments. A set of calibration tests using glass capillary sources of varying size resolves the material characteristics and synthetic Green's Functions such that uncertainty in source location is reduced to 3σ<1mm; typical source radii are 1mm. Well-isolated events with corner frequencies on the order of 0.1 MHz (Mw -6) are recorded at 20 MHz and initially band-pass filtered from 0.1 to 1.0 MHz; in comparison, large earthquakes with corner frequencies around 0.1 Hz are commonly filtered from 0.1 to 1.0 Hz. We compare results of the inversion and video recording to slip distribution predicted by the Cattaneo partial slip asperity and numerical modeling. Not all asperities are large enough to resolve individually so some results must be interpreted as the smoothed effects of clusters of tiny contacts. For large asperities, partial slip is observed originating at the asperity edges and moving inward as predicted by the theory. Furthermore, expanding shear rupture fronts are observed as they reach resistive patches of asperities and halt or continue, depending on the relative energies of rupture and resistance.

  19. Sudden acquired retinal degeneration syndrome in western Canada: 93 cases.

    PubMed

    Leis, Marina L; Lucyshyn, Danica; Bauer, Bianca S; Grahn, Bruce H; Sandmeyer, Lynne S

    2017-11-01

    This study reviewed clinical data from dogs diagnosed with sudden acquired retinal degeneration syndrome (SARDS) in western Canada. Medical records from the Western College of Veterinary Medicine from 2002 to 2016 showed that 93 cases of SARDS were diagnosed based on presentation for sudden blindness and a bilaterally extinguished electroretinogram. The most common pure breeds were the miniature schnauzer, dachshund, and pug. The mean age at diagnosis was 8.1 years and males and females were equally affected. Most of the dogs were presented with normal non-chromatic, but abnormal chromatic pupillary light reflexes. The incidence of retinal degeneration as detected via ophthalmoscopy increased over time after SARDS diagnosis. Polyuria, polydipsia, polyphagia, weight gain, elevated liver enzyme values, isosthenuria, and proteinuria were common clinical and laboratory findings. Chromatic pupillary light reflex testing may be more valuable than non-chromatic pupillary light testing in detecting pupil response abnormalities in dogs with SARDS, although electroretinography remains the definitive diagnostic test.

  20. Sudden acquired retinal degeneration syndrome in western Canada: 93 cases

    PubMed Central

    Leis, Marina L.; Lucyshyn, Danica; Bauer, Bianca S.; Grahn, Bruce H.; Sandmeyer, Lynne S.

    2017-01-01

    This study reviewed clinical data from dogs diagnosed with sudden acquired retinal degeneration syndrome (SARDS) in western Canada. Medical records from the Western College of Veterinary Medicine from 2002 to 2016 showed that 93 cases of SARDS were diagnosed based on presentation for sudden blindness and a bilaterally extinguished electroretinogram. The most common pure breeds were the miniature schnauzer, dachshund, and pug. The mean age at diagnosis was 8.1 years and males and females were equally affected. Most of the dogs were presented with normal non-chromatic, but abnormal chromatic pupillary light reflexes. The incidence of retinal degeneration as detected via ophthalmoscopy increased over time after SARDS diagnosis. Polyuria, polydipsia, polyphagia, weight gain, elevated liver enzyme values, isosthenuria, and proteinuria were common clinical and laboratory findings. Chromatic pupillary light reflex testing may be more valuable than non-chromatic pupillary light testing in detecting pupil response abnormalities in dogs with SARDS, although electroretinography remains the definitive diagnostic test. PMID:29089658

  1. Clinical and laboratory characteristics of ocular syphilis: a new face in the era of HIV co-infection.

    PubMed

    Lee, Sun Young; Cheng, Vincent; Rodger, Damien; Rao, Narsing

    2015-12-01

    Ocular syphilis is reemerging as an important cause of uveitis in the new era of common co-infection with HIV. This study will reveal the clinical and laboratory characteristics in the group of individuals co-infected with ocular syphilis and HIV compared with HIV-negative individuals. In this retrospective observational case series, medical records of patients diagnosed with ocular syphilis with serologic support from 2008 to 2014 were reviewed. Ocular and systemic manifestation and laboratory profiles were reviewed. Twenty-nine eyes of 16 consecutive patients (10 HIV-positive and 6 HIV-negative) were included. All patients were males, and mean age of onset for ocular syphilis was 43 (mean 42.65 ± 13.13). In both HIV-positive and HIV-negative groups, ocular manifestations of syphilis were variable including anterior uveitis (4 eyes), posterior uveitis (8 eyes), panuveitis (13 eyes), and isolated papillitis (4 eyes). In HIV-positive patients, panuveitis was the most common feature (12/18 eyes, 67 %) and serum rapid plasma reagin (RPR) titers were significantly higher (range 1:64-1:16,348; mean 1:768; p = 0.018) than in HIV-negative patients. Upon the diagnosis of ocular syphilis in HIV-positive patients, HIV-1 viral load was high (median 206,887 copies/ml) and CD4 cell count ranged from 127 to 535 cells/ml (mean 237 ± 142; median 137). Regardless of HIV status, cerebrospinal fluid (CSF) exam was frequently abnormal: positive CSF fluorescent treponemal antibody absorption (FTA-ABS) or Venereal Disease Research Laboratory (VDRL) test results in seven patients or either elevated CSF WBC count or elevated CSF protein in six patients. Our results reveal that the patients with ocular syphilis with high serum RPR titers may have concomitant HIV infection requiring further testing for HIV status and ocular syphilis is likely associated with the central nervous system involvement and therefore needs to be managed according to the treatment recommendations for neurosyphilis.

  2. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India.

    PubMed

    Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh

    2018-01-01

    An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.

  3. The standardization of urine particle counting in medical laboratories--a Polish experience with the EQA programme.

    PubMed

    Cwiklińska, Agnieszka; Kąkol, Judyta; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Pacanis, Anastasis; Rogulski, Jerzy; Wróblewska, Małgorzata

    2012-02-01

    Given the common problems with the standardization of urine particle counting methods and the great variability in the results obtained by Polish laboratories under international Labquality External Quality Assessment (EQA), we initiated educational recovery activities. Detailed instructions on how to perform the standardized examination were sent to EQA participants, as was a questionnaire forms which enabled information to be gathered in respect to the procedures being applied. Laboratory results were grouped according to the method declared on the EQA 'Result' form or according to a manual examination procedure established on the basis of the questionnaire. The between-laboratory CVs for leukocyte and erythrocyte counts were calculated for each group and compared using the Mann-Whitney test. Significantly lower between-laboratory CVs (p = 0.03) were achieved for leukocyte counting among the laboratories that analysed control specimens in accordance with standardized procedures as compared with those which used non-standardized procedures. We also observed a visible lower variability for erythrocyte counting. Unfortunately despite our activities, only a few of the Polish laboratories applied the standardized examination procedures, and only 29% of the results could have been considered to be standardized (16% - manual methods, 13% - automated systems). The standardization of urine particle counting methods continues to be a significant problem in medical laboratories and requires further recovery activities which can be conducted using the EQA scheme.

  4. A Unique Software System For Simulation-to-Flight Research

    NASA Technical Reports Server (NTRS)

    Chung, Victoria I.; Hutchinson, Brian K.

    2001-01-01

    "Simulation-to-Flight" is a research development concept to reduce costs and increase testing efficiency of future major aeronautical research efforts at NASA. The simulation-to-flight concept is achieved by using common software and hardware, procedures, and processes for both piloted-simulation and flight testing. This concept was applied to the design and development of two full-size transport simulators, a research system installed on a NASA B-757 airplane, and two supporting laboratories. This paper describes the software system that supports the simulation-to-flight facilities. Examples of various simulation-to-flight experimental applications were also provided.

  5. Is the OJIP Test a Reliable Indicator of Winter Hardiness and Freezing Tolerance of Common Wheat and Triticale under Variable Winter Environments?

    PubMed Central

    Rapacz, Marcin; Sasal, Monika; Kalaji, Hazem M.; Kościelniak, Janusz

    2015-01-01

    OJIP analysis, which explores changes in photosystem II (PSII) photochemical performance, has been used as a measure of plant susceptibility to stress. However, in the case of freezing tolerance and winter hardiness, which are highly environmentally variable, the use of this method can give ambiguous results depending on the species as well as the sampling year and time. To clarify this issue, we performed chlorophyll fluorescence measurements over three subsequent winters (2010/11, 2011/12 and 2012/13) on 220 accessions of common winter wheat and 139 accessions of winter triticale. After freezing, leaves were collected from cold-acclimated plants in the laboratory and field-grown plants. Observations of field survival in seven locations across Poland and measurements of freezing tolerance of the studied plants were also recorded. Our results confirm that the OJIP test is a reliable indicator of winter hardiness and freezing tolerance of common wheat and triticale under unstable winter environments. Regardless of species, the testing conditions giving the most reliable results were identical, and the reliability of the test could be easily checked by analysis of some relationships between OJIP-test parameters. We also found that triticale is more winter hardy and freezing tolerant than wheat. In addition, the two species were characterized by different patterns of photosynthetic apparatus acclimation to cold. PMID:26230839

  6. Is the OJIP Test a Reliable Indicator of Winter Hardiness and Freezing Tolerance of Common Wheat and Triticale under Variable Winter Environments?

    PubMed

    Rapacz, Marcin; Sasal, Monika; Kalaji, Hazem M; Kościelniak, Janusz

    2015-01-01

    OJIP analysis, which explores changes in photosystem II (PSII) photochemical performance, has been used as a measure of plant susceptibility to stress. However, in the case of freezing tolerance and winter hardiness, which are highly environmentally variable, the use of this method can give ambiguous results depending on the species as well as the sampling year and time. To clarify this issue, we performed chlorophyll fluorescence measurements over three subsequent winters (2010/11, 2011/12 and 2012/13) on 220 accessions of common winter wheat and 139 accessions of winter triticale. After freezing, leaves were collected from cold-acclimated plants in the laboratory and field-grown plants. Observations of field survival in seven locations across Poland and measurements of freezing tolerance of the studied plants were also recorded. Our results confirm that the OJIP test is a reliable indicator of winter hardiness and freezing tolerance of common wheat and triticale under unstable winter environments. Regardless of species, the testing conditions giving the most reliable results were identical, and the reliability of the test could be easily checked by analysis of some relationships between OJIP-test parameters. We also found that triticale is more winter hardy and freezing tolerant than wheat. In addition, the two species were characterized by different patterns of photosynthetic apparatus acclimation to cold.

  7. Passing of northern pike and common carp through experimental barriers designed for use in wetland restoration

    USGS Publications Warehouse

    French, John R. P.; Wilcox, Douglas A.; Nichols, S. Jerrine

    1999-01-01

    Restoration plans for Metzger Marsh, a coastal wetland on the south shore of western Lake Erie, incorporated a fish-control system designed to restrict access to the wetland by large common carp (Cyprinus carpio). Ingress fish passageways in the structure contain slots into which experimental grates of varying size and shape can be placed to selectively allow entry and transfer of other large fish species while minimizing the number of common carp to be handled. We tested different sizes and shapes of grates in experimental tanks in the laboratory to determine the best design for testing in the field. We also tested northern pike (Esox lucius) because lack of access to wetland spawning habitat has greatly reduced their populations in western Lake Erie. Based on our results, vertical bar grates were chosen for installation because common carp were able to pass through circular grates smaller than body height by compressing their soft abdomens; they passed through rectangular grates on the diagonal. Vertical bar grates with 5-cm spacing that were installed across much of the control structure should limit access of common carp larger than 34 cm total length (TL) and northern pike larger than 70 cm. Vertical bar grates selected for initial field trials in the fish passageway had spacings of 5.8 and 6.6 cm, which increased access by common carp to 40 and 47 cm TL and by northern pike to 76 and 81 cm, respectively. The percentage of potential common carp biomass (fish seeking entry) that must be handled in lift baskets in the passageway increased from 0.9 to 4.8 to 15.4 with each increase in spacing between bars. Further increases in spacing would greatly increase the number of common carp that would have to be handled. The results of field testing should be useful in designing selective fish-control systems for other wetland restoration sites adjacent to large water bodies.

  8. First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

    PubMed Central

    Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie

    2013-01-01

    Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449

  9. Positive predictive value estimates for cell-free noninvasive prenatal screening from data of a large referral genetic diagnostic laboratory.

    PubMed

    Petersen, Andrea K; Cheung, Sau Wai; Smith, Janice L; Bi, Weimin; Ward, Patricia A; Peacock, Sandra; Braxton, Alicia; Van Den Veyver, Ignatia B; Breman, Amy M

    2017-12-01

    Since its debut in 2011, cell-free fetal DNA screening has undergone rapid expansion with respect to both utilization and coverage. However, conclusive data regarding the clinical validity and utility of this screening tool, both for the originally included common autosomal and sex-chromosomal aneuploidies as well as the more recently added chromosomal microdeletion syndromes, have lagged behind. Thus, there is a continued need to educate clinicians and patients about the current benefits and limitations of this screening tool to inform pre- and posttest counseling, pre/perinatal decision making, and medical risk assessment/management. The objective of this study was to determine the positive predictive value and false-positive rates for different chromosomal abnormalities identified by cell-free fetal DNA screening using a large data set of diagnostic testing results on invasive samples submitted to the laboratory for confirmatory studies. We tested 712 patient samples sent to our laboratory to confirm a cell-free fetal DNA screening result, indicating high risk for a chromosome abnormality. We compiled data from all cases in which the indication for confirmatory testing was a positive cell-free fetal DNA screen, including the common trisomies, sex chromosomal aneuploidies, microdeletion syndromes, and other large genome-wide copy number abnormalities. Testing modalities included fluorescence in situ hybridization, G-banded karyotype, and/or chromosomal microarray analysis performed on chorionic villus samples, amniotic fluid, or postnatally obtained blood samples. Positive predictive values and false-positive rates were calculated from tabulated data. The positive predictive values for trisomy 13, 18, and 21 were consistent with previous reports at 45%, 76%, and 84%, respectively. For the microdeletion syndrome regions, positive predictive values ranged from 0% for detection of Cri-du-Chat syndrome and Prader-Willi/Angelman syndrome to 14% for 1p36 deletion syndrome and 21% for 22q11.2 deletion syndrome. Detection of sex chromosomal aneuploidies had positive predictive values of 26% for monosomy X, 50% for 47,XXX, and 86% for 47,XXY. The positive predictive values for detection of common autosomal and sex chromosomal aneuploidies by cell-free fetal DNA screening were comparable with other studies. Identification of microdeletions was associated with lower positive predictive values and higher false-positive rates, likely because of the low prevalence of the individual targeted microdeletion syndromes in the general population. Although the obtained positive predictive values compare favorably with those seen in traditional screening approaches for common aneuploidies, they highlight the importance of educating clinicians and patients on the limitations of cell-free fetal DNA screening tests. Improvement of the cell-free fetal DNA screening technology and continued monitoring of its performance after introduction into clinical practice will be important to fully establish its clinical utility. Nonetheless, our data provide valuable information that may aid result interpretation, patient counseling, and clinical decision making/management. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol.

    PubMed

    Eckfeldt, J H; Copeland, K R

    1993-04-01

    Proficiency testing using stabilized control materials has been used for decades as a means of monitoring and improving performance in the clinical laboratory. Often, the commonly used proficiency testing materials exhibit "matrix effects" that cause them to behave differently from fresh human specimens in certain clinical analytic systems. Because proficiency testing is the primary method in which regulatory agencies have chosen to evaluate clinical laboratory performance, the College of American Pathologists (CAP) has proposed guidelines for investigating the influence of matrix effects on their Survey results. The purpose of this investigation was to determine the feasibility, usefulness, and potential problems associated with this CAP Matrix Effect Analytical Protocol, in which fresh patient specimens and CAP proficiency specimens are analyzed simultaneously by a field method and a definitive, reference, or other comparative method. The optimal outcome would be that both the fresh human and CAP Survey specimens agree closely with the comparative method result. However, this was not always the case. Using several different analytic configurations, we were able to demonstrate matrix and calibration biases for several of the analytes investigated.

  11. Use of the VS-sense swab in diagnosing vulvovaginitis.

    PubMed

    Sobel, Jack D; Nyirjesy, Paul; Kessary, Hadar; Ferris, Daron G

    2009-09-01

    Although pH assessment of vaginal secretions is beneficial for diagnosing vaginitis, it is not commonly done. The purpose of this study was to determine the performance characteristics of the VS-Sense (pH test) swab (Common Sense, Ltd., Caesarea, Israel) in augmenting the diagnosis of vaginitis. We prospectively studied 193 women with acute vulvovaginal symptoms and 74 asymptomatic controls at three medical centers. The VS-Sense swab was administered intravaginally, and results were interpreted by a nurse. These results were compared with final clinical and laboratory diagnoses. In women with an elevated pH caused by bacterial vaginosis (BV), trichomonas, and other types of vaginitis, the VS-Sense test sensitivity and specificity were 82.3% (102 of 124) (95% CI 74.4%-88.5%) and 94.2% (129 of 137) (95% CI 88.8%-97.4%), respectively. There was an 86.2% (95% CI 81.3%-90.1%) overall agreement between pH paper and VS-Sense swab results. The VS-Sense test offers an alternative approach to measuring vaginal pH with nitrazine paper. Use of this simple, more rapid test may facilitate the diagnosis of vulvovaginitis.

  12. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel a fuel cell test in the Fuel Cell Development and Test Laboratory. Capability Hubs The Fuel Cell

  13. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2013-10-01 2013-10-01 false What drugs do laboratories test for? 40.85 Section...

  14. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  15. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2014-10-01 2014-10-01 false What drugs do laboratories test for? 40.85 Section...

  16. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  17. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  18. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  19. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2011-10-01 2011-10-01 false What drugs do laboratories test for? 40.85 Section...

  20. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2012-10-01 2012-10-01 false What drugs do laboratories test for? 40.85 Section...

  1. 49 CFR 40.85 - What drugs do laboratories test for?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2010-10-01 2010-10-01 false What drugs do laboratories test for? 40.85 Section...

  2. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  3. Basic problems of serological laboratory diagnosis.

    PubMed

    Fierz, Walter

    2004-01-01

    Serological laboratory diagnosis of infectious diseases is inflicted with several kinds of basic problems. One difficulty relates to the fact that the serological diagnosis of infectious diseases is double indirect: The first indirect aim in diagnosing an infectious disease is to identify the microbial agent that caused the disease. The second indirect aim is to identify this infectious agent by measuring the patient's immune response to the potential agent. Thus, the serological test is neither measuring directly disease nor the cause of the disease, but the patient's immune system. The latter poses another type of problem, because each person's immune system is unique. The immune response to an infectious agent is usually of polyclonal nature, and the exact physicochemical properties of antibodies are unique for each clone of antibody. The clonal makeup and composition and, therefore, the way an individual's immune system sees an infectious agent, depends not only on the genetic background of the person but also on the individual experience from former encounters with various infectious agents. In consequence, the reaction of a patient's serum in an analytical system is not precisely predictable. Also, the antigenic makeup of an infectious agent is not always foreseeable. Antigenic variations leading to different serotypes is a quite common phenomenon. Altogether, these biological problems lead to complexities in selecting the appropriate tests and strategies for testing, in interpreting the results, and in standardizing serological test systems. For that reason, a close collaboration of the laboratory with the clinic is mandatory to avoid erroneous conclusions from serological test results, which might lead to wrong decisions in patient care.

  4. 76 FR 14323 - Small Business Size Standards: Professional, Scientific and Technical Services

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-16

    ... SBA to establish a common size standard for the Computer Systems Design and Related Services....0 12.0 Testing Laboratories........ 10.0 5.0 $10.0 $10.0 541410 0.8 5.1 0.2 0.557 5.0 7.0 Interior Design Services.... 5.0 5.0 5.0 $5.0 541420 1.3 9.5 0.714 5.0 7.0 Industrial Design Services.. 5.0 5.0 $5...

  5. Study of Dominant Factors Affecting Cerchar Abrasivity Index

    NASA Astrophysics Data System (ADS)

    Rostami, Jamal; Ghasemi, Amireza; Alavi Gharahbagh, Ehsan; Dogruoz, Cihan; Dahl, Filip

    2014-09-01

    The Cerchar abrasion index is commonly used to represent rock abrasion for estimation of bit life and wear in various mining and tunneling applications. Although the test is simple and fast, there are some discrepancies in the test results related to the equipment used, condition of the rock surface, operator skills, and procedures used in conducting and measuring the wear surface. This paper focuses on the background of the test and examines the influence of various parameters on Cerchar testing including pin hardness, surface condition of specimens, petrographical and geomechanical properties, test speed, applied load, and method of measuring wear surface. Results of Cerchar tests on a set of rock specimens performed at different laboratories are presented to examine repeatability of the tests. In addition, the preliminary results of testing with a new device as a potential alternative testing system for rock abrasivity measurement are discussed.

  6. Do recent US Supreme Court rulings on patenting of genes and genetic diagnostics affect the practice of genetic screening and diagnosis in prenatal and reproductive care?

    PubMed Central

    Chandrasekharan, Subhashini; McGuire, Amy L.; Van den Veyver, Ignatia B.

    2015-01-01

    Thousands of patents have been awarded that claim human gene sequences and their uses, and some have been challenged in court. In a recent high-profile case, Association for Molecular Pathology, et al. vs. Myriad Genetics, Inc., et al., the United States Supreme Court ruled that genes are natural occurring substances and therefore not patentable through “composition of matter” claims. The consequences of this ruling will extend well beyond ending Myriad's monopoly over BRCA testing, and may affect similar monopolies of other commercial laboratories for tests involving other genes. It could also simplify intellectual property issues surrounding genome-wide clinical sequencing, which can generate results for genes covered by intellectual property. Non-invasive prenatal testing (NIPT) for common aneuploidies using cell-free fetal (cff) DNA in maternal blood is currently offered through commercial laboratories and is also the subject of ongoing patent litigation. The recent Supreme Court decision in the Myriad case has already been invoked by a lower district court in NIPT litigation and resulted in invalidation of primary claims in a patent on currently marketed cffDNA-based testing for chromosomal aneuploidies. PMID:24989832

  7. Classification of anemia for gastroenterologists

    PubMed Central

    Moreno Chulilla, Jose Antonio; Romero Colás, Maria Soledad; Gutiérrez Martín, Martín

    2009-01-01

    Most anemia is related to the digestive system by dietary deficiency, malabsorption, or chronic bleeding. We review the World Health Organization definition of anemia, its morphological classification (microcytic, macrocytic and normocytic) and pathogenic classification (regenerative and hypo regenerative), and integration of these classifications. Interpretation of laboratory tests is included, from the simplest (blood count, routine biochemistry) to the more specific (iron metabolism, vitamin B12, folic acid, reticulocytes, erythropoietin, bone marrow examination and Schilling test). In the text and various algorithms, we propose a hierarchical and logical way to reach a diagnosis as quickly as possible, by properly managing the medical interview, physical examination, appropriate laboratory tests, bone marrow examination, and other complementary tests. The prevalence is emphasized in all sections so that the gastroenterologist can direct the diagnosis to the most common diseases, although the tables also include rare diseases. Digestive diseases potentially causing anemia have been studied in preference, but other causes of anemia have been included in the text and tables. Primitive hematological diseases that cause anemia are only listed, but are not discussed in depth. The last section is dedicated to simplifying all items discussed above, using practical rules to guide diagnosis and medical care with the greatest economy of resources and time. PMID:19787825

  8. Laboratories | Energy Systems Integration Facility | NREL

    Science.gov Websites

    laboratories to be safely divided into multiple test stand locations (or "capability hubs") to enable Fabrication Laboratory Energy Systems High-Pressure Test Laboratory Energy Systems Integration Laboratory Energy Systems Sensor Laboratory Fuel Cell Development and Test Laboratory High-Performance Computing

  9. Telehealth physician oversight over direct to consumer testing: doctors working with patients towards patient empowerment.

    PubMed

    Chung, Rick

    2012-06-01

    Patient empowerment has increased the demand for direct to consumer (DTC) laboratory testing. Multiple professional societies and advocacy groups have raised concerns over how DTC laboratory testing is being offered to consumers without proper physician oversight. Physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner. Using telehealth protocols and standards established by professional health organizations and state regulators, physician telehealth oversight in DTC laboratory test ordering can be effective to increase patient access to healthcare services. With proper physician oversight in test interpretation, post-test counseling, and information collaboration, DTC laboratory testing can remain a reliable and convenient option for consumers. Working within the channel of distribution of most DTC laboratory testing, physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner to ensure that proper test interpretation, counseling, and information collaboration are achieved. Physician telehealth services can properly oversee DTC laboratory testing to ensure that proper test interpretation, counseling, and information collaboration are achieved.

  10. EGFR Mutation Testing Practices within the Asia Pacific Region

    PubMed Central

    Kerr, Keith M.; Utomo, Ahmad; Rajadurai, Pathmanathan; Tran, Van Khanh; Du, Xiang; Chou, Teh-Ying; Enriquez, Ma. Luisa D.; Lee, Geon Kook; Iqbal, Jabed; Shuangshoti, Shanop; Chung, Jin-Haeng; Hagiwara, Koichi; Liang, Zhiyong; Normanno, Nicola; Park, Keunchil; Toyooka, Shinichi; Tsai, Chun-Ming; Waring, Paul; Zhang, Li; McCormack, Rose; Ratcliffe, Marianne; Itoh, Yohji; Sugeno, Masatoshi; Mok, Tony

    2015-01-01

    Introduction: The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non–small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods. Methods: A retrospective survey of records from NSCLC patients tested for EGFR mutations during 2011 was conducted in 11 Asian Pacific countries at 40 sites that routinely performed EGFR mutation testing during that period. Patient records were used to complete an online questionnaire at each site. Results: Of the 22,193 NSCLC patient records surveyed, 31.8% (95% confidence interval: 31.2%–32.5%) were tested for EGFR mutations. The rate of EGFR mutation positivity was 39.6% among the 10,687 cases tested. The majority of samples were biopsy and/or cytology samples (71.4%). DNA sequencing was the most commonly used testing method accounting for 40% and 32.5% of tissue and cytology samples, respectively. A pathology report was available only to 60.0% of the sites, and 47.5% were not members of a Quality Assurance Scheme. Conclusions: In 2011, EGFR mutation testing practices varied widely across Asia. These data provide a reference platform from which to improve the molecular diagnosis of NSCLC, and EGFR mutation testing in particular, in Asia. PMID:25376513

  11. EGFR mutation testing practices within the Asia Pacific region: results of a multicenter diagnostic survey.

    PubMed

    Yatabe, Yasushi; Kerr, Keith M; Utomo, Ahmad; Rajadurai, Pathmanathan; Tran, Van Khanh; Du, Xiang; Chou, Teh-Ying; Enriquez, Ma Luisa D; Lee, Geon Kook; Iqbal, Jabed; Shuangshoti, Shanop; Chung, Jin-Haeng; Hagiwara, Koichi; Liang, Zhiyong; Normanno, Nicola; Park, Keunchil; Toyooka, Shinichi; Tsai, Chun-Ming; Waring, Paul; Zhang, Li; McCormack, Rose; Ratcliffe, Marianne; Itoh, Yohji; Sugeno, Masatoshi; Mok, Tony

    2015-03-01

    The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non-small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods. A retrospective survey of records from NSCLC patients tested for EGFR mutations during 2011 was conducted in 11 Asian Pacific countries at 40 sites that routinely performed EGFR mutation testing during that period. Patient records were used to complete an online questionnaire at each site. Of the 22,193 NSCLC patient records surveyed, 31.8% (95% confidence interval: 31.2%-32.5%) were tested for EGFR mutations. The rate of EGFR mutation positivity was 39.6% among the 10,687 cases tested. The majority of samples were biopsy and/or cytology samples (71.4%). DNA sequencing was the most commonly used testing method accounting for 40% and 32.5% of tissue and cytology samples, respectively. A pathology report was available only to 60.0% of the sites, and 47.5% were not members of a Quality Assurance Scheme. In 2011, EGFR mutation testing practices varied widely across Asia. These data provide a reference platform from which to improve the molecular diagnosis of NSCLC, and EGFR mutation testing in particular, in Asia.

  12. Clostridium difficile Infection and Patient-Specific Antimicrobial Resistance Testing Reveals a High Metronidazole Resistance Rate.

    PubMed

    Barkin, Jodie A; Sussman, Daniel A; Fifadara, Nimita; Barkin, Jamie S

    2017-04-01

    Clostridium difficile (CD) infection (CDI) causes marked morbidity and mortality, accounting for large healthcare expenditures annually. Current CDI treatment guidelines focus on clinical markers of patient severity to determine the preferred antibiotic regimen of metronidazole versus vancomycin. The antimicrobial resistance patterns for patients with CD are currently unknown. The aim of this study was to define the antimicrobial resistance patterns for CD. This study included all patients with stools sent for CD testing to a private laboratory (DRG Laboratory, Alpharetta, Georgia) in a 6-month period from across the USA. Patient data was de-identified, with only age, gender, and zip-code available per laboratory protocol. All samples underwent PCR testing followed by hybridization for CD toxin regions A and B. Only patients with CD-positive PCR were analyzed. Antimicrobial resistance testing using stool genomic DNA evaluated presence of imidazole- and vancomycin-resistant genes using multiplex PCR gene detection. Of 2743, 288 (10.5%) stool samples were positive for CD. Six were excluded per protocol. Of 282, 193 (69.4%) were women, and average age was 49.4 ± 18.7 years. Of 282, 62 were PCR positive for toxins A and B, 160 for toxin A positive alone, and 60 for toxin B positive alone. Antimicrobial resistance testing revealed 134/282 (47.5%) patients resistant to imidazole, 17 (6.1%) resistant to vancomycin, and 9 (3.2%) resistant to imidazole and vancomycin. CD-positive patients with presence of imidazole-resistant genes from stool DNA extract was a common phenomenon, while vancomycin resistance was uncommon. Similar to treatment of other infections, antimicrobial resistance testing should play a role in CDI clinical decision-making algorithms to enable more expedited and cost-effective delivery of patient care.

  13. What resources are used in emergency departments in rural sub-Saharan Africa? A retrospective analysis of patient care in a district-level hospital in Uganda.

    PubMed

    Bitter, Cindy Carol; Rice, Brian; Periyanayagam, Usha; Dreifuss, Bradley; Hammerstedt, Heather; Nelson, Sara W; Bisanzo, Mark; Maling, Samuel; Chamberlain, Stacey

    2018-02-24

    To determine the most commonly used resources (provider procedural skills, medications, laboratory studies and imaging) needed to care for patients. A single emergency department (ED) of a district-level hospital in rural Uganda. 26 710 patient visits. Procedures were performed for 65.6% of patients, predominantly intravenous cannulation, wound care, bladder catheterisation and orthopaedic procedures. Medications were administered to 87.6% of patients, most often pain medications, antibiotics, intravenous fluids, antimalarials, nutritional supplements and vaccinations. Laboratory testing was used for 85% of patients, predominantly malaria smears, rapid glucose testing, HIV assays, blood counts, urinalyses and blood type. Radiology testing was performed for 17.3% of patients, including X-rays, point-of-care ultrasound and formal ultrasound. This study describes the skills and resources needed to care for a large prospective cohort of patients seen in a district hospital ED in rural sub-Saharan Africa. It demonstrates that the vast majority of patients were treated with a small formulary of critical medications and limited access to laboratories and imaging, but providers require a broad set of decision-making and procedural skills. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. A systematic review of oral herpetic viral infections in cancer patients: commonly used outcome measures and interventions.

    PubMed

    Elad, Sharon; Ranna, Vinisha; Ariyawardana, Anura; Correa, Maria Elvira Pizzigatti; Tilly, Vanessa; Nair, Raj G; Rouleau, Tanya; Logan, Richard M; Pinto, Andres; Charette, Veronica; Saunders, Debbie P; Jensen, Siri Beier

    2017-02-01

    To review the literature for outcome measures for oral viral infections in cancer patients. A secondary aim was to update the Multinational Association of Supportive Care in Cancer/International Society of Oral Oncology (MASCC/ISOO) clinical practice guidelines for the management of oral viral infections in cancer patients. Databases were searched for articles published in the English language, 1981-2013. Studies that met the eligibility criteria were reviewed systematically. The data about the outcome measures were classified according to the aim of the study: prevention, treatment, or non-interventional. The results of interventional studies were compared to the 2010 MASCC/ISOO publication. Multiple clinical and laboratory tests were used to measure oral viral infections, with great variability between studies. Most of the studies were about Herpes Simplex Virus (HSV). The outcome measure that was most commonly used was the presence of HSV infection diagnosed based on a combination of suggestive clinical presentation with a positive laboratory result. HSV culture was the most commonly reported laboratory outcome measure. Acyclovir and valacyclovir were consistently reported to be efficacious in the management of oral herpetic infections. No new data on the quality of life and economic aspects was found. Considering the variability in outcome measures reported to assess oral herpetic infections the researcher should select carefully the appropriate measures based on the objective of the study. Acyclovir and valacyclovir are effective in the management of oral herpetic infections in patients receiving treatment for cancer. Studies on newer anti-viral drugs may be useful to address the issue of anti-viral resistance.

  15. Shallow Reflection Method for Water-Filled Void Detection and Characterization

    NASA Astrophysics Data System (ADS)

    Zahari, M. N. H.; Madun, A.; Dahlan, S. H.; Joret, A.; Hazreek, Z. A. M.; Mohammad, A. H.; Izzaty, R. A.

    2018-04-01

    Shallow investigation is crucial in enhancing the characteristics of subsurface void commonly encountered in civil engineering, and one such technique commonly used is seismic-reflection technique. An assessment of the effectiveness of such an approach is critical to determine whether the quality of the works meets the prescribed requirements. Conventional quality testing suffers limitations including: limited coverage (both area and depth) and problems with resolution quality. Traditionally quality assurance measurements use laboratory and in-situ invasive and destructive tests. However geophysical approaches, which are typically non-invasive and non-destructive, offer a method by which improvement of detection can be measured in a cost-effective way. Of this seismic reflection have proved useful to assess void characteristic, this paper evaluates the application of shallow seismic-reflection method in characterizing the water-filled void properties at 0.34 m depth, specifically for detection and characterization of void measurement using 2-dimensional tomography.

  16. [Modularization by the open standard. (I)].

    PubMed

    Hirano, H

    2000-10-01

    We are proceeding with the project called "Open LA21 Project" in the course of the clinical laboratory automation toward the 21st century. With the modular system that realizes integration, downsizing, a reasonable price, and is the future course in the clinical testing automation system as well, we aim to establish common standards among manufacturers as the only way to create user friendly market environments where the proper competition exists among the manufacturers. The common standards which are in preparation by the participating companies as "Open module system standards" are the standards which are going to be made public. They are intended to guarantee connection, compatibility of the products in conformity with the standards. In this project, we intend to realize the modular system that integrates each field, such as chemistry, hematology, coagulation/fibrinolysis, immunology, urinalysis in an early stage, and contribute positively to restructuring and upgrading the "raison d'etre" of the 21st century clinical testing.

  17. Diagnosing night sweats.

    PubMed

    Viera, Anthon J; Bond, Michael M; Yates, Scott W

    2003-03-01

    Night sweats are a common outpatient complaint, yet literature on the subject is scarce. Tuberculosis and lymphoma are diseases in which night sweats are a dominant symptom, but these are infrequently found to be the cause of night sweats in modern practice. While these diseases remain important diagnostic considerations in patients with night sweats, other diagnoses to consider include human immunodeficiency virus, gastroesophageal reflux disease, obstructive sleep apnea, hyperthyroidism, hypoglycemia, and several less common diseases. Antihypertensives, antipyretics, other medications, and drugs of abuse such as alcohol and heroin may cause night sweats. Serious causes of night sweats can be excluded with a thorough history, physical examination, and directed laboratory and radiographic studies. If a history and physical do not reveal a possible diagnosis, physicians should consider a purified protein derivative, complete blood count, human immunodeficiency virus test, thyroid-stimulating hormone test, erythrocyte sedimentation rate evaluation, chest radiograph, and possibly chest and abdominal computed tomographic scans and bone marrow biopsy.

  18. Evaluation of airborne asbestos exposure from routine handling of asbestos-containing wire gauze pads in the research laboratory.

    PubMed

    Garcia, Ediberto; Newfang, Daniel; Coyle, Jayme P; Blake, Charles L; Spencer, John W; Burrelli, Leonard G; Johnson, Giffe T; Harbison, Raymond D

    2018-07-01

    Three independently conducted asbestos exposure evaluations were conducted using wire gauze pads similar to standard practice in the laboratory setting. All testing occurred in a controlled atmosphere inside an enclosed chamber simulating a laboratory setting. Separate teams consisting of a laboratory technician, or technician and assistant simulated common tasks involving wire gauze pads, including heating and direct wire gauze manipulation. Area and personal air samples were collected and evaluated for asbestos consistent with the National Institute of Occupational Safety Health method 7400 and 7402, and the Asbestos Hazard Emergency Response Act (AHERA) method. Bulk gauze pad samples were analyzed by Polarized Light Microscopy and Transmission Electron Microscopy to determine asbestos content. Among air samples, chrysotile asbestos was the only fiber found in the first and third experiments, and tremolite asbestos for the second experiment. None of the air samples contained asbestos in concentrations above the current permissible regulatory levels promulgated by OSHA. These findings indicate that the level of asbestos exposure when working with wire gauze pads in the laboratory setting is much lower than levels associated with asbestosis or asbestos-related lung cancer and mesothelioma. Copyright © 2018. Published by Elsevier Inc.

  19. Laboratory Diagnosis of Infections in Cancer Patients: Challenges and Opportunities

    PubMed Central

    2016-01-01

    Infections remain a significant cause of morbidity and mortality in cancer patients. The differential diagnosis for these patients is often wide, and the timely selection of the right clinical tests can have a significant impact on their survival. However, laboratory findings with current methodologies are often negative, challenging clinicians and laboratorians to continue the search for the responsible pathogen. Novel methodologies are providing increased sensitivity and rapid turnaround time to results but also challenging our interpretation of what is a clinically significant pathogen in cancer patients. This minireview provides an overview of the most common infections in cancer patients and discusses some of the challenges and opportunities for the clinical microbiologist supporting the care of cancer patients. PMID:27280421

  20. Best practice in primary care pathology: review 5

    PubMed Central

    Smellie, W S A; Forth, J; Ryder, S; Galloway, M J; Wood, A C; Watson, I D

    2006-01-01

    This fifth best practice review examines three series of common primary care questions in laboratory medicine: (1) minor liver function test abnormalities; (2) laboratory monitoring of patients receiving lithium; and (3) investigation of possible venous thromboembolism. The review is presented in question–answer format, referenced for each question series. The recommendations represent a precis of guidance found using a standardised literature search of national and international guidance notes, consensus statements, health policy documents and evidence‐based medicine reviews, supplemented by Medline Embase searches to identify relevant primary research documents. They are not standards but form a guide to be set in the clinical context. Most are consensus‐based rather than evidence‐based. They will be updated periodically to take account of new information. PMID:16644875

  1. Measuring the glycemic index of foods: interlaboratory study.

    PubMed

    Wolever, Thomas M S; Brand-Miller, Jennie C; Abernethy, John; Astrup, Arne; Atkinson, Fiona; Axelsen, Mette; Björck, Inger; Brighenti, Furio; Brown, Rachel; Brynes, Audrey; Casiraghi, M Cristina; Cazaubiel, Murielle; Dahlqvist, Linda; Delport, Elizabeth; Denyer, Gareth S; Erba, Daniela; Frost, Gary; Granfeldt, Yvonne; Hampton, Shelagh; Hart, Valerie A; Hätönen, Katja A; Henry, C Jeya; Hertzler, Steve; Hull, Sarah; Jerling, Johann; Johnston, Kelly L; Lightowler, Helen; Mann, Neil; Morgan, Linda; Panlasigui, Leonora N; Pelkman, Christine; Perry, Tracy; Pfeiffer, Andreas F H; Pieters, Marlien; Ramdath, D Dan; Ramsingh, Rayna T; Robert, S Daniel; Robinson, Carol; Sarkkinen, Essi; Scazzina, Francesca; Sison, Dave Clark D; Sloth, Birgitte; Staniforth, Jane; Tapola, Niina; Valsta, Liisa M; Verkooijen, Inge; Weickert, Martin O; Weseler, Antje R; Wilkie, Paul; Zhang, Jian

    2008-01-01

    Many laboratories offer glycemic index (GI) services. We assessed the performance of the method used to measure GI. The GI of cheese-puffs and fruit-leather (centrally provided) was measured in 28 laboratories (n=311 subjects) by using the FAO/WHO method. The laboratories reported the results of their calculations and sent the raw data for recalculation centrally. Values for the incremental area under the curve (AUC) reported by 54% of the laboratories differed from central calculations. Because of this and other differences in data analysis, 19% of reported food GI values differed by >5 units from those calculated centrally. GI values in individual subjects were unrelated to age, sex, ethnicity, body mass index, or AUC but were negatively related to within-individual variation (P=0.033) expressed as the CV of the AUC for repeated reference food tests (refCV). The between-laboratory GI values (mean+/-SD) for cheese-puffs and fruit-leather were 74.3+/-10.5 and 33.2+/-7.2, respectively. The mean laboratory GI was related to refCV (P=0.003) and the type of restrictions on alcohol consumption before the test (P=0.006, r2=0.509 for model). The within-laboratory SD of GI was related to refCV (P<0.001), the glucose analysis method (P=0.010), whether glucose measures were duplicated (P=0.008), and restrictions on dinner the night before (P=0.013, r2=0.810 for model). The between-laboratory SD of the GI values is approximately 9. Standardized data analysis and low within-subject variation (refCV<30%) are required for accuracy. The results suggest that common misconceptions exist about which factors do and do not need to be controlled to improve precision. Controlled studies and cost-benefit analyses are needed to optimize GI methodology. The trial was registered at clinicaltrials.gov as NCT00260858.

  2. Statement of the ESHG on direct-to-consumer genetic testing for health-related purposes

    PubMed Central

    2010-01-01

    Many private companies offer direct-to-consumer (DTC) genetic testing services. Some tests may detect severe and highly penetrant monogenic disorders, while other tests are for genetic variants found associated with increased susceptibility for common and complex diseases in large-scale population studies. Through its Public and Professional Policy committee followed by member and expert consultation, the European Society of Human Genetics has developed the following policy on advertising and provision of predictive genetic tests by such DTC companies: (1) clinical utility of a genetic test shall be an essential criterion for deciding to offer this test to a person or a group of persons; (2) laboratories providing genetic tests should comply with accepted quality standards, including those regarding laboratory personnel qualifications; (3) information about the purpose and appropriateness of testing should be given before the test is done; (4) genetic counselling appropriate to the type of test and disease should be offered; and for some tests psychosocial evaluation and follow-up should be available; (5) privacy and confidentiality of sensitive genetic information should be secured and the data safely guarded; (6) special measures should be taken to avoid inappropriate testing of minors and other legally incapacitated persons; (7) all claims regarding genetic tests should be transparent; advertisement should be unbiased and marketing of genetic tests should be fair; (8) in biomedical research, health care and marketing, respect should be given to relevant ethical principles, as well as international treaties and recommendations regarding genetic testing; and (9) nationally approved guidelines considering all the above-mentioned aspects should be made and followed. PMID:20736974

  3. Principles for high-quality, high-value testing.

    PubMed

    Power, Michael; Fell, Greg; Wright, Michael

    2013-02-01

    A survey of doctors working in two large NHS hospitals identified over 120 laboratory tests, imaging investigations and investigational procedures that they considered not to be overused. A common suggestion in this survey was that more training was required. And, this prompted the development of a list of core principles for high-quality, high-value testing. The list can be used as a framework for training and as a reference source. The core principles are: (1) Base testing practices on the best available evidence. (2) Apply the evidence on test performance with careful judgement. (3) Test efficiently. (4) Consider the value (and affordability) of a test before requesting it. (5) Be aware of the downsides and drivers of overdiagnosis. (6) Confront uncertainties. (7) Be patient-centred in your approach. (8) Consider ethical issues. (9) Be aware of normal cognitive limitations and biases when testing. (10) Follow the 'knowledge journey' when teaching and learning these core principles.

  4. Description of new dry granular materials of variable cohesion and friction coefficient: Implications for laboratory modeling of the brittle crust

    NASA Astrophysics Data System (ADS)

    Abdelmalak, M. M.; Bulois, C.; Mourgues, R.; Galland, O.; Legland, J.-B.; Gruber, C.

    2016-08-01

    Cohesion and friction coefficient are fundamental parameters for scaling brittle deformation in laboratory models of geological processes. However, they are commonly not experimental variable, whereas (1) rocks range from cohesion-less to strongly cohesive and from low friction to high friction and (2) strata exhibit substantial cohesion and friction contrasts. This brittle paradox implies that the effects of brittle properties on processes involving brittle deformation cannot be tested in laboratory models. Solving this paradox requires the use of dry granular materials of tunable and controllable brittle properties. In this paper, we describe dry mixtures of fine-grained cohesive, high friction silica powder (SP) and low-cohesion, low friction glass microspheres (GM) that fulfill this requirement. We systematically estimated the cohesions and friction coefficients of mixtures of variable proportions using two independent methods: (1) a classic Hubbert-type shear box to determine the extrapolated cohesion (C) and friction coefficient (μ), and (2) direct measurements of the tensile strength (T0) and the height (H) of open fractures to calculate the true cohesion (C0). The measured values of cohesion increase from 100 Pa for pure GM to 600 Pa for pure SP, with a sub-linear trend of the cohesion with the mixture GM content. The two independent cohesion measurement methods, from shear tests and tension/extensional tests, yield very similar results of extrapolated cohesion (C) and show that both are robust and can be used independently. The measured values of friction coefficients increase from 0.5 for pure GM to 1.05 for pure SP. The use of these granular material mixtures now allows testing (1) the effects of cohesion and friction coefficient in homogeneous laboratory models and (2) testing the effect of brittle layering on brittle deformation, as demonstrated by preliminary experiments. Therefore, the brittle properties become, at last, experimental variables.

  5. Results of Screening of Apparently Healthy Senior and Geriatric Dogs.

    PubMed

    Willems, A; Paepe, D; Marynissen, S; Smets, P; Van de Maele, I; Picavet, P; Duchateau, L; Daminet, S

    2017-01-01

    There is a growing interest in health care of elderly dogs; however, scientific information about physical and laboratory examination findings in this age group is limited. To describe systolic blood pressure (SBP), and results of physical examination and laboratory tests in senior and geriatric dogs that were judged by the owner to be healthy. Hundred client-owned dogs. Dogs were prospectively recruited. Owners completed a questionnaire. SBP measurement, physical, orthopedic and neurologic examination, direct fundoscopy and Schirmer tear test were performed. Complete blood count, serum biochemistry, and urinalysis were evaluated. Forty-one senior and 59 geriatric dogs were included. Mean SBP was 170 ± 38 mmHg, and 53 dogs had SBP > 160 mmHg. Thirty-nine animals were overweight. A heart murmur was detected in 22, severe calculus in 21 and 1 or more (sub)cutaneous masses in 56 dogs. Thirty-two dogs had increased serum creatinine, 29 hypophosphatemia, 27 increased ALP, 25 increased ALT, and 23 leukopenia. Crystalluria, mostly amorphous crystals, was commonly detected (62/96). Overt proteinuria and borderline proteinuria were detected in 13 and 18 of 97 dogs, respectively. Four dogs had a positive urine bacterial culture. Frequency of orthopedic problems, frequency of (sub)cutaneous masses, and platelet count were significantly higher in geriatric compared with senior dogs. Body temperature, hematocrit, serum albumin, and serum total thyroxine concentration were significantly lower in geriatric compared with senior dogs. Physical and laboratory abnormalities are common in apparently healthy elderly dogs. Veterinarians play a key role in implementing health screening and improving health care for elderly pets. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES

    PubMed Central

    Perera, Inoka Eranda; Litton, Charles D.

    2015-01-01

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m−1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters’ Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety. PMID:26229418

  7. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES.

    PubMed

    Perera, Inoka Eranda; Litton, Charles D

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m -1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters' Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety.

  8. National Chemistry Teacher Safety Survey

    NASA Astrophysics Data System (ADS)

    Plohocki, Barbra A.

    This study evaluated the status of secondary school instructional chemistry laboratory safety using a survey instrument which focused on Teacher background Information, Laboratory Safety Equipment, Facility Safety, General Safety, and a Safety Content Knowledge Survey. A fifty question survey instrument based on recent research and questions developed by the researcher was mailed to 500 secondary school chemistry teachers who participated in the 1993 one-week Woodrow Wilson National Fellowship Foundation Chemistry Institute conducted at Princeton University, New Jersey. The data received from 303 respondents was analyzed by t tests and Analysis of Variance (ANOVA). The level of significance for the study was set at ~\\ <.05. There was no significant mean difference in test performance on the Safety Content Knowledge Survey and secondary school chemistry teachers who have had undergraduate and/or graduate safety training and those who have not had undergraduate and/or graduate safety training. Secondary school chemistry teachers who attended school district sponsored safety inservices did not score higher on the Safety Content Knowledge Survey than teachers who did not attend school district sponsored safety inservice sessions. The type of school district (urban, suburban, or rural) had no significant correlation to the type of laboratory safety equipment found in the instructional chemistry laboratory. The certification area (chemistry or other type of certificate which may or may not include chemistry) of the secondary school teacher had no significant correlation to the type of laboratory equipment found in the instructional chemistry laboratory. Overall, this study indicated a majority of secondary school chemistry teachers were interested in attending safety workshops applicable to chemistry safety. Throughout this research project, many teachers indicated they were not adequately instructed on the collegiate level in science safety and had to rely on common sense and self-study in their future teaching careers.

  9. Laboratory animals and respiratory allergies: The prevalence of allergies among laboratory animal workers and the need for prophylaxis

    PubMed Central

    Ferraz, Erica; Arruda, Luisa Karla de Paula; Bagatin, Ericson; Martinez, Edson Z; Cetlin, Andrea A; Simoneti, Christian S; Freitas, Amanda S; Martinez, José A B; Borges, Marcos C; Vianna, Elcio O

    2013-01-01

    OBJECTIVE: Subjects exposed to laboratory animals are at a heightened risk of developing respiratory and allergic diseases. These diseases can be prevented by simple measures such as the use of personal protective equipment. We report here the primary findings of the Laboratory Animals and Respiratory Allergies Study regarding the prevalence of allergic diseases among laboratory animal workers, the routine use of preventive measures in laboratories and animal facilities, and the need for prevention programs. METHODS: Animal handlers and non-animal handlers from 2 Brazilian universities (University of São Paulo and State University of Campinas) answered specific questionnaires to assess work conditions and symptoms. These subjects also underwent spirometry, a bronchial challenge test with mannitol, and skin prick tests for 11 common allergens and 5 occupational allergens (rat, mouse, guinea pig, hamster, and rabbit). RESULTS: Four hundred fifty-five animal handlers (32±10 years old [mean±SD], 209 men) and 387 non-animal handlers (33±11 years old, 121 men) were evaluated. Sensitization to occupational allergens was higher among animal handlers (16%) than non-animal handlers (3%, p<0.01). Accessibility to personal protective equipment was measured at 85% (median, considering 73 workplaces of the animal handler group). Nineteen percent of the animal handlers indicated that they wear a respirator at all times while handling animals or working in the animal room, and only 25% of the animal handlers had received an orientation about animal-induced allergies, asthma, or rhinitis. CONCLUSION: In conclusion, our data indicate that preventive programs are necessary. We suggest providing individual advice to workers associated with institutional programs to promote a safer work environment. PMID:23778494

  10. Practices for Identifying and Rejecting Hemolyzed Specimens Are Highly Variable in Clinical Laboratories.

    PubMed

    Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L

    2015-08-01

    Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.

  11. Evaluation of first-draw whole blood, point-of-care cardiac markers in the context of the universal definition of myocardial infarction: a comparison of a multimarker panel to troponin alone and to testing in the central laboratory.

    PubMed

    Lee-Lewandrowski, Elizabeth; Januzzi, James L; Grisson, Ricky; Mohammed, Asim A; Lewandrowski, Grant; Lewandrowski, Kent

    2011-04-01

    Previous studies evaluating point-of-care testing (POCT) for cardiac biomarkers did not use current recommendations for troponin cutoff values or recognize the recent universal definition of acute myocardial infarction. Traditionally, achieving optimal sensitivity for the detection of myocardial injury on initial presentation required combining cardiac troponin and/or creatine kinase isoenzyme MB with an early marker, usually myoglobin. In recent years, the performance of central laboratory combining cardiac troponin assays has improved significantly, potentially obviating the need for a multimarker panel to achieve optimum sensitivity. To compare 2 commonly used POCT strategies to a fourth generation, central laboratory cardiac troponin T assay on first-draw specimens from patients being evaluated for acute myocardial infarction in the emergency department. The 2 strategies included a traditional POCT multimarker panel and a newer POCT method using cardiac troponin I alone. Blood specimens from 204 patients presenting to the emergency department with signs and/or symptoms of myocardial ischemia were measured on the 2 POCT systems and by a central laboratory method. The diagnosis for each patient was determined by retrospective chart review. The cardiac troponin T assasy alone was more sensitive for acute myocardial infarction than the multimarker POCT panel with equal or better specificity. When compared with a POCT troponin I, the cardiac troponin T was also more sensitive, but this difference was not significant. The POCT troponin I alone also had the same sensitivity as the multimarker panel. Testing for combining cardiac troponin alone using newer, commercially available, central laboratory or POCT assays performed with equal or greater sensitivity to acute myocardial infarction as the older, traditional, multimarker panel. In the near future, high-sensitivity, central laboratory troponins will be available for routine clinical use. As a result, the quality gap between central laboratories and older POCT methods will continue to widen, unless the performance of the POCT methods is improved.

  12. Commercial Molecular Tests for Fungal Diagnosis from a Practical Point of View.

    PubMed

    Lackner, Michaela; Lass-Flörl, Cornelia

    2017-01-01

    The increasing interest in molecular diagnostics is a result of tremendously improved knowledge on fungal infections in the past 20 years and the rapid development of new methods, in particular polymerase chain reaction. High expectations have been placed on molecular diagnostics, and the number of laboratories now using the relevant technology is rapidly increasing-resulting in an obvious need for standardization and definition of laboratory organization. In the past 10 years, multiple new molecular tools were marketed for the detection of DNA, antibodies, cell wall components, or other antigens. In contrast to classical culture methods, molecular methods do not detect a viable organisms, but only molecules which indicate its presence; this can be nucleic acids, cell components (antigens), or antibodies (Fig. 1). In this chapter, an overview is provided on commercially available detection tools, their strength and how to use them. A main focus is laid on providing tips and tricks that make daily life easier. We try to focus and mention methodical details which are not highlighted in the manufacturer's instructions of these test kits, but are based on our personal experience in the laboratory. Important to keep in mind is that molecular tools cannot replace culture, microscopy, or a critical view on patients' clinical history, signs, and symptoms, but provide a valuable add on tool. Diagnosis should not be based solely on a molecular test, but molecular tools might deliver an important piece of information that helps matching the diagnostic puzzle to a diagnosis, in particular as few tests are in vitro diagnostic tests (IVD) or only part of the whole test carries the IVD certificate (e.g., DNA extraction is often not included). Please be aware that the authors do not claim to provide a complete overview on all commercially available diagnostic assays being currently marketed for fungal detection, as those are subject to constant change. A main focus is put on commonly used panfungal assays and pathogen-specific assays, including Aspergillus-specific, Candida-specific, Cryptococcus specific, Histoplasma-specific, and Pneumocystis-specific assays. Assays are categorized according to their underlying principle in either antigen-detecting or antibody-detecting or DNA-detecting (Fig. 1). Other non-DNA-detecting nucleic acid methods such as FISH and PNA FISH are not summarized in this chapter and an overview on test performance, common false positives, and the clinical evaluation of commercial tests in studies is provided already in a previous book series by Javier Yugueros Marcos and David H. Pincus (Marcos and Pincus, Methods Mol Biol 968:25-54, 2013).

  13. Quality in the molecular microbiology laboratory.

    PubMed

    Wallace, Paul S; MacKay, William G

    2013-01-01

    In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.

  14. Household solvent products: a shelf survey with laboratory analysis. Final report, October 1984-July 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maklan, D.M.; Steele, D.H.; Dietz, S.K.

    1987-07-01

    This study was conducted to provide information on the incidence and concentration of six chlorocarbons in common household products. The objectives of the study were to: (1) determine which categories of consumer products contain the chemical methylene chloride and/or five potential substitute solvents (1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, carbon tetrachloride, and 1,1,2-trichlorotrifluoroethane); and (2) analyze brands representing each product category to determine the concentration of these chemicals in household products. A national sample of household products was selected and laboratory tested to determine the incidence and concentration of the six target chlorocarbons. The following are some of the major findings. Fifty-eight percentmore » of the 67 product categories had at least one brand test positive for one or more of the target analytes. Thirty-four percent of the 1026 brands tested positive for at least one of the six target chlorocarbons. Thirty-four percent of the brands tested positive for methylene chloride, 14% tested positive for 1,1,1-trichloroethane, and less than 4% of the brands were positive on any of the remaining four chlorocarbons. The concentration of analyte varied considerably between brands of the same product category. Only 56% of the brands with chlorocarbons were so labeled.« less

  15. Methods for the Quality Control of Inactivated Poliovirus Vaccines.

    PubMed

    Wilton, Thomas

    2016-01-01

    Inactivated poliovirus vaccine (IPV) plays an instrumental role in the Global Poliovirus Eradication Initiative (GPEI). The quality of IPV is controlled by assessment of the potency of vaccine batches. The potency of IPV can be assessed by both in vivo and in vitro methods. In vitro potency assessment is based upon the assessment of the quantity of the D-Antigen (D-Ag) units in an IPV. The D-Ag unit is used as a measure of potency as it is largely expressed on native infectious virions and is the protective immunogen. The most commonly used in vitro test is the indirect ELISA which is used to ensure consistency throughout production.A range of in vivo assays have been developed in monkeys, chicks, guinea pigs, mice, and rats to assess the potency of IPV. All are based on assessment of the neutralizing antibody titer within the sera of the respective animal model. The rat potency test has become the favored in vivo potency test as it shows minimal variation between laboratories and the antibody patterns of rats and humans are similar. With the development of transgenic mice expressing the human poliovirus receptor, immunization-challenge tests have been developed to assess the potency of IPVs. This chapter describes in detail the methodology of these three laboratory tests to assess the quality of IPVs.

  16. An internationally standardized species identification test for use on suspected seized rhinoceros horn in the illegal wildlife trade.

    PubMed

    Ewart, Kyle M; Frankham, Greta J; McEwing, Ross; Webster, Lucy M I; Ciavaglia, Sherryn A; Linacre, Adrian M T; The, Dang Tat; Ovouthan, Kanitia; Johnson, Rebecca N

    2018-01-01

    Rhinoceros (rhino) numbers have dwindled substantially over the past century. As a result, three of the five species are now considered to be critically endangered, one species is vulnerable and one species is near-threatened. Poaching has increased dramatically over the past decade due to a growing demand for rhino horn products, primarily in Asia. Improved wildlife forensic techniques, such as validated tests for species identification of seized horns, are critical to aid current enforcement and prosecution efforts and provide a deterrent to future rhino horn trafficking. Here, we present an internationally standardized species identification test based on a 230 base pair cytochrome-b region. This test improves on previous nested PCR protocols and can be used for the discrimination of samples with <20pg of template DNA, thus suitable for DNA extracted from horn products. The assay was designed to amplify water buffalo samples, a common 'rhino horn' substitute, but to exclude human DNA, a common contaminant. Phylogenetic analyses using this partial cytochrome-b region resolved the five extant rhino species. Testing successfully returned a sequence and correct identification for all of the known rhino horn samples and vouchered rhino samples from museum and zoo collections, and provided species level identification for 47 out of 52 unknown samples from seizures. Validation and standardization was carried out across five different laboratories, in four different countries, demonstrating it to be an effective and reproducible test, robust to inter laboratory variation in equipment and consumables (such as PCR reagents). This is one of the first species identification tests to be internationally standardized to produce data for evidential proceedings and the first published validated test for rhinos, one of the flagship species groups of the illegal wildlife trade and for which forensic tools are urgently required. This study serves as a model for how species identification tests should be standardized and disseminated for wildlife forensic testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. 49 CFR 40.107 - Who may inspect laboratories?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.107 Who may inspect laboratories? As a...-regulated employer that contracts with the laboratory for drug testing under the DOT drug testing program...

  18. 49 CFR 40.107 - Who may inspect laboratories?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.107 Who may inspect laboratories? As a...-regulated employer that contracts with the laboratory for drug testing under the DOT drug testing program...

  19. 49 CFR 40.107 - Who may inspect laboratories?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.107 Who may inspect laboratories? As a...-regulated employer that contracts with the laboratory for drug testing under the DOT drug testing program...

  20. 49 CFR 40.107 - Who may inspect laboratories?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.107 Who may inspect laboratories? As a...-regulated employer that contracts with the laboratory for drug testing under the DOT drug testing program...

  1. 49 CFR 40.107 - Who may inspect laboratories?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.107 Who may inspect laboratories? As a...-regulated employer that contracts with the laboratory for drug testing under the DOT drug testing program...

  2. Quality specifications for the extra-analytical phase of laboratory testing: Reference intervals and decision limits.

    PubMed

    Ceriotti, Ferruccio

    2017-07-01

    Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Laboratories | NREL

    Science.gov Websites

    | Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition

  4. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  5. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  6. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  7. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  8. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How long does the laboratory retain specimens after testing? (a) As a laboratory testing the primary...

  9. Towards an evaluation framework for Laboratory Information Systems.

    PubMed

    Yusof, Maryati M; Arifin, Azila

    Laboratory testing and reporting are error-prone and redundant due to repeated, unnecessary requests and delayed or missed reactions to laboratory reports. Occurring errors may negatively affect the patient treatment process and clinical decision making. Evaluation on laboratory testing and Laboratory Information System (LIS) may explain the root cause to improve the testing process and enhance LIS in supporting the process. This paper discusses a new evaluation framework for LIS that encompasses the laboratory testing cycle and the socio-technical part of LIS. Literature review on discourses, dimensions and evaluation methods of laboratory testing and LIS. A critical appraisal of the Total Testing Process (TTP) and the human, organization, technology-fit factors (HOT-fit) evaluation frameworks was undertaken in order to identify error incident, its contributing factors and preventive action pertinent to laboratory testing process and LIS. A new evaluation framework for LIS using a comprehensive and socio-technical approach is outlined. Positive relationship between laboratory and clinical staff resulted in a smooth laboratory testing process, reduced errors and increased process efficiency whilst effective use of LIS streamlined the testing processes. The TTP-LIS framework could serve as an assessment as well as a problem-solving tool for the laboratory testing process and system. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  10. Probable Diagnosis of a Patient with Niemann-Pick Disease Type C: Managing Pitfalls of Exome Sequencing.

    PubMed

    Zeiger, William A; Jamal, Nasheed I; Scheuner, Maren T; Pittman, Patricia; Raymond, Kimiyo M; Morra, Massimo; Mishra, Shri K

    2018-02-17

    Here, we present a case of a 31-year-old man with progressive cognitive decline, ataxia, and dystonia. Extensive laboratory, radiographic, and targeted genetic studies over the course of several years failed to yield a diagnosis. Initial whole exome sequencing through a commercial laboratory identified several variants of uncertain significance; however, follow-up clinical examination and testing ruled each of these out. Eventually, repeat whole exome sequencing identified a known pathogenic intronic variant in the NPC1 gene (NM_000271.4, c.1554-1009G>A) and an additional heterozygous exonic variant of uncertain significance in the NPC1 gene (NM_000271.4, c.2524T>C). Follow-up biochemical testing was consistent with a diagnosis of probable Niemann-Pick disease Type C (NP-C). This case illustrates the potential of whole exome sequencing for diagnosing rare complex neurologic diseases. It also identifies several potential common pitfalls that must be navigated by clinicians when interpreting commercial whole exome sequencing results.

  11. HMGCR-associated myositis: a New Zealand case series and estimate of incidence.

    PubMed

    Kennedy, N; Keating, P; O'Donnell, J

    2016-05-01

    Statins are one of the most commonly prescribed drugs in New Zealand, with 525 772 or 16.5% of the adult New Zealand population prescribed a statin between June 2013 and July 2014. While generally well-tolerated, statins are known to cause a range of muscle-related side effects, ranging from myalgia to life-threatening rhabdomyolysis. Recently, it has been recognised that in rare instances, statins can induce an immune-mediated necrotising myositis with antibodies against 3-hydroxy-3-methylglutaryl-coenzyme A reductase (HMGCR), the enzymatic target of statins. In 2014, anti-HMGCR antibody testing was introduced to Canterbury Health Laboratories (CHL), with this being the only laboratory in New Zealand performing this test during the period of this case series. This article describes an index case and characterises the clinical features of a subsequent 12-month series. From this series, we estimated the yearly incidence of HMGCR-associated myositis at 1.7/million/year or ~1/90 000 New Zealand statin users. © 2016 Royal Australasian College of Physicians.

  12. An investigation of normal urine with a creatinine concentration under the cutoff of 20 mg/dL for specimen validity testing in a toxicology laboratory.

    PubMed

    Holden, Brad; Guice, Erica A

    2014-05-01

    In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.

  13. Fulminate Hepatic Failure as an Initial Presentation of Non-Hodgkin Lymphoma: A Case Report

    PubMed Central

    Ahmadi, Bizhan; Shafieipour, Sara; Akhavan Rezayat, Kambiz

    2014-01-01

    Viral hepatitis and toxins comprise most common causes of fulminate hepatic failure that are often diagnosed with standard laboratory tests. Herein we discuss a rare, difficult to diagnosis etiology of acute liver failure (ALF). A 62-year-old man presented with a two-week history of fever and fatigue. At four days before admission he became lethargic. His past medical and drug histories were unremarkable. Physical examination revealed generalized jaundice, fever and loss of consciousness. Laboratory tests showed elevated liver transaminases with direct hyper-bilirubinemia. Abdominal ultrasonography and CT scan showed hepatosplenomegaly and para-aortic abdominal lymphadenopathy. A further work-up included liver biopsy. The histopathology and imunohistochemistry was compatible with diffuse large B-cell lymphoma. He underwent high dose glucocorticoid therapy but his condition deteriorated rapidly and he died eight days after admission. ALF as an initial manifestation of malignant hepatic infiltration is extremely rare yet should be considered in all patients with unknown hepatic failure that are highly suspicious for malignant neoplasm. PMID:24872870

  14. Hepatitis E virus: do locally acquired infections in Australia necessitate laboratory testing in acute hepatitis patients with no overseas travel history?

    PubMed Central

    Shrestha, Ashish C.; Faddy, Helen M.; Flower, Robert L. P.; Seed, Clive R.; Keller, Anthony J.

    2015-01-01

    Summary Hepatitis E virus (HEV) is emerging as a global public health threat. Water-borne HEV outbreaks are common in developing countries and are associated with genotypes 1 and 2. In industrialised countries, sporadic cases of zoonotic transmission associated with genotypes 3 and 4 are increasingly being reported. Transfusion- and transplantation-transmitted HEV have been documented, although ingestion of contaminated food is thought to be the major transmission route. Severe disease is possible and chronic hepatitis infection occurs in solid-organ-transplant recipients and in patients with immunosuppressive disorders. In Australia, HEV cases are mainly travellers returning from disease endemic countries. Indeed, there are few reported cases of locally acquired HEV. Pigs in Australia have been shown to be infected with HEV, which indicates the possibility of zoonotic transmission. The extent of locally acquired infection is not known, however it may be greater than expected and may necessitate laboratory testing in patients reporting no overseas travel. PMID:25560836

  15. Research and test facilities

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

  16. Evidence-based analysis of field testing of medical electrical equipment.

    PubMed

    Taktak, A G; Brown, M C

    2006-01-01

    Field testing of medical electrical equipment remains a topic of debate amongst biomedical engineers. A questionnaire was circulated among members of the main professional body for Medical Engineering Departments in the UK and Ireland and in the Medical Physics and Engineering Mailbase Server. The aim of the questionnaire was to establish consensus on common practice on the frequency and type of safety tests carried out in the field and common sources of hazards and risk management. Twenty-six replies were received in total. A clear majority of 54% of the respondents reported that they carried out safety tests on hospital-based medical equipment on a yearly basis. For other equipment, regular tests were carried out by 58% on loan equipment and by 69% on medical electrical systems. Laboratory equipment on the other hand were not tested in 42% of the cases. Domiciliary and research equipment were only tested in 11% and 15% of the cases respectively. A clear majority of 93% said that they label equipment after tests, 34% said that they always record the actual values (as opposed to pass or fail) and 54% said they carry out functional test as part of the safety test. Although 61% of failures were attributed to the mains lead, only 50% of the respondents said that they had a management system in place for detachable mains leads.

  17. Development and implementation of a custom integrated database with dashboards to assist with hematopathology specimen triage and traffic

    PubMed Central

    Azzato, Elizabeth M.; Morrissette, Jennifer J. D.; Halbiger, Regina D.; Bagg, Adam; Daber, Robert D.

    2014-01-01

    Background: At some institutions, including ours, bone marrow aspirate specimen triage is complex, with hematopathology triage decisions that need to be communicated to downstream ancillary testing laboratories and many specimen aliquot transfers that are handled outside of the laboratory information system (LIS). We developed a custom integrated database with dashboards to facilitate and streamline this workflow. Methods: We developed user-specific dashboards that allow entry of specimen information by technologists in the hematology laboratory, have custom scripting to present relevant information for the hematopathology service and ancillary laboratories and allow communication of triage decisions from the hematopathology service to other laboratories. These dashboards are web-accessible on the local intranet and accessible from behind the hospital firewall on a computer or tablet. Secure user access and group rights ensure that relevant users can edit or access appropriate records. Results: After database and dashboard design, two-stage beta-testing and user education was performed, with the first focusing on technologist specimen entry and the second on downstream users. Commonly encountered issues and user functionality requests were resolved with database and dashboard redesign. Final implementation occurred within 6 months of initial design; users report improved triage efficiency and reduced need for interlaboratory communications. Conclusions: We successfully developed and implemented a custom database with dashboards that facilitates and streamlines our hematopathology bone marrow aspirate triage. This provides an example of a possible solution to specimen communications and traffic that are outside the purview of a standard LIS. PMID:25250187

  18. Multilaboratory evaluation of methods for detecting enteric viruses in soils.

    PubMed Central

    Hurst, C J; Schaub, S A; Sobsey, M D; Farrah, S R; Gerba, C P; Rose, J B; Goyal, S M; Larkin, E P; Sullivan, R; Tierney, J T

    1991-01-01

    Two candidate methods for the recovery and detection of viruses in soil were subjected to round robin comparative testing by members of the American Society for Testing and Materials D19:24:04:04 Subcommittee Task Group. Selection of the methods, designated "Berg" and "Goyal," was based on results of an initial screening which indicated that both met basic criteria considered essential by the task group. Both methods utilized beef extract solutions to achieve desorption and recovery of viruses from representative soils: a fine sand soil, an organic muck soil, a sandy loam soil, and a clay loam soil. One of the two methods, Goyal, also used a secondary concentration of resulting soil eluants via low-pH organic flocculation to achieve a smaller final assay volume. Evaluation of the two methods was simultaneously performed in replicate by nine different laboratories. Each of the produced samples was divided into portions, and these were respectively subjected to quantitative viral plaque assay by both the individual, termed independent, laboratory which had done the soil processing and a single common reference laboratory, using a single cell line and passage level. The Berg method seemed to produce slightly higher virus recovery values; however, the differences in virus assay titers for samples produced by the two methods were not statistically significant (P less than or equal to 0.05) for any one of the four soils. Despite this lack of a method effect, there was a statistically significant laboratory effect exhibited by assay titers from the independent versus reference laboratories for two of the soils, sandy loam and clay loam. PMID:1849712

  19. Multilaboratory evaluation of methods for detecting enteric viruses in soils.

    PubMed

    Hurst, C J; Schaub, S A; Sobsey, M D; Farrah, S R; Gerba, C P; Rose, J B; Goyal, S M; Larkin, E P; Sullivan, R; Tierney, J T

    1991-02-01

    Two candidate methods for the recovery and detection of viruses in soil were subjected to round robin comparative testing by members of the American Society for Testing and Materials D19:24:04:04 Subcommittee Task Group. Selection of the methods, designated "Berg" and "Goyal," was based on results of an initial screening which indicated that both met basic criteria considered essential by the task group. Both methods utilized beef extract solutions to achieve desorption and recovery of viruses from representative soils: a fine sand soil, an organic muck soil, a sandy loam soil, and a clay loam soil. One of the two methods, Goyal, also used a secondary concentration of resulting soil eluants via low-pH organic flocculation to achieve a smaller final assay volume. Evaluation of the two methods was simultaneously performed in replicate by nine different laboratories. Each of the produced samples was divided into portions, and these were respectively subjected to quantitative viral plaque assay by both the individual, termed independent, laboratory which had done the soil processing and a single common reference laboratory, using a single cell line and passage level. The Berg method seemed to produce slightly higher virus recovery values; however, the differences in virus assay titers for samples produced by the two methods were not statistically significant (P less than or equal to 0.05) for any one of the four soils. Despite this lack of a method effect, there was a statistically significant laboratory effect exhibited by assay titers from the independent versus reference laboratories for two of the soils, sandy loam and clay loam.

  20. White piedra, black piedra, tinea versicolor, and tinea nigra: contribution to the diagnosis of superficial mycosis.

    PubMed

    Veasey, John Verrinder; Avila, Ricardo Bertozzi de; Miguel, Barbara Arruda Fraletti; Muramatu, Laura Hitomi

    2017-01-01

    Superficial mycoses are fungal infections restricted to the stratum corneum and to the hair shafts, with no penetration in the epidermis; they are: white piedra, black piedra, tinea versicolor, and tinea nigra. This study presents images of mycological tests performed in the laboratory, as well as exams performed at the authors office, in order to improve the dermatologist's knowledge about the diagnosis of these dermatoses, which are common in many countries.

Top