NASA Technical Reports Server (NTRS)
Lukash, James A.; Daley, Earl
2011-01-01
This work describes the design and development effort to adapt rapid-development space hardware by creating a ground system using solutions of low complexity, mass, & cost. The Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft is based on the modular common spacecraft bus architecture developed at NASA Ames Research Center. The challenge was building upon the existing modular common bus design and development work and improving the LADEE spacecraft design by adding an Equipotential Voltage Reference (EVeR) system, commonly referred to as a ground system. This would aid LADEE in meeting Electromagnetic Environmental Effects (E3) requirements, thereby making the spacecraft more compatible with itself and its space environment. The methods used to adapt existing hardware are presented, including provisions which may be used on future spacecraft.
Venturelli, Gustavo L; Brod, Fábio C A; Rossi, Gabriela B; Zimmermann, Naíra F; Oliveira, Jaison P; Faria, Josias C; Arisi, Ana C M
2014-11-01
The Embrapa 5.1 genetically modified (GM) common bean was approved for commercialization in Brazil. Methods for the quantification of this new genetically modified organism (GMO) are necessary. The development of a suitable endogenous reference is essential for GMO quantification by real-time PCR. Based on this, a new taxon-specific endogenous reference quantification assay was developed for Phaseolus vulgaris L. Three genes encoding common bean proteins (phaseolin, arcelin, and lectin) were selected as candidates for endogenous reference. Primers targeting these candidate genes were designed and the detection was evaluated using the SYBR Green chemistry. The assay targeting lectin gene showed higher specificity than the remaining assays, and a hydrolysis probe was then designed. This assay showed high specificity for 50 common bean samples from two gene pools, Andean and Mesoamerican. For GM common bean varieties, the results were similar to those obtained for non-GM isogenic varieties with PCR efficiency values ranging from 92 to 101 %. Moreover, this assay presented a limit of detection of ten haploid genome copies. The primers and probe developed in this work are suitable to detect and quantify either GM or non-GM common bean.
Kerr, Kathleen F; Serikawa, Kyle A; Wei, Caimiao; Peters, Mette A; Bumgarner, Roger E
2007-01-01
The reference design is a practical and popular choice for microarray studies using two-color platforms. In the reference design, the reference RNA uses half of all array resources, leading investigators to ask: What is the best reference RNA? We propose a novel method for evaluating reference RNAs and present the results of an experiment that was specially designed to evaluate three common choices of reference RNA. We found no compelling evidence in favor of any particular reference. In particular, a commercial reference showed no advantage in our data. Our experimental design also enabled a new way to test the effectiveness of pre-processing methods for two-color arrays. Our results favor using intensity normalization and foregoing background subtraction. Finally, we evaluate the sensitivity and specificity of data quality filters, and we propose a new filter that can be applied to any experimental design and does not rely on replicate hybridizations.
ERIC Educational Resources Information Center
Martyniuk, Waldemar
2012-01-01
The Council of Europe's "Common European Framework of Reference for Languages" is rapidly becoming a powerful instrument for shaping language education policies in Europe and beyond. The task of relating language policies, language curricula, teacher education and training, textbook and course design and content, examinations and…
ERIC Educational Resources Information Center
Friend Wise, Alyssa; Padmanabhan, Poornima; Duffy, Thomas M.
2009-01-01
This mixed-methods study probed the effectiveness of three kinds of objects (video, theory, metaphor) as common reference points for conversations between online learners (student teachers). Individuals' degree of detail-focus was examined as a potentially interacting covariate and the outcome measure was learners' level of tacit knowledge related…
Circular common-path point diffraction interferometer.
Du, Yongzhao; Feng, Guoying; Li, Hongru; Vargas, J; Zhou, Shouhuan
2012-10-01
A simple and compact point-diffraction interferometer with circular common-path geometry configuration is developed. The interferometer is constructed by a beam-splitter, two reflection mirrors, and a telescope system composed by two lenses. The signal and reference waves travel along the same path. Furthermore, an opaque mask containing a reference pinhole and a test object holder or test window is positioned in the common focal plane of the telescope system. The object wave is divided into two beams that take opposite paths along the interferometer. The reference wave is filtered by the reference pinhole, while the signal wave is transmitted through the object holder. The reference and signal waves are combined again in the beam-splitter and their interference is imaged in the CCD. The new design is compact, vibration insensitive, and suitable for the measurement of moving objects or dynamic processes.
Design of the Core Stage Inter-Tank Umbilical {CSITU) Compliance Mechanism
NASA Technical Reports Server (NTRS)
Smith, Kurt R.
2013-01-01
Project Goals: a) Design the compliance mechanism for the CSITU system to a 30% level -3D models completed in Pro/Engineer -Relevant design analysis b) Must meet all system requirements and establish basis for proceeding with detailed design. Tasks to be completed: A design that meets requirements for the 30% design review, 01/16/2013. Umbilical arms provide commodities to the launch vehicle prior to T-0. Commodities can range anywhere from hydraulics, pneumatics, cryogenic, electrical, ECS, etc ... Umbilicals commonly employ truss structures to deliver commodities to vehicle. Common configurations include: -Tilt-up -Swing Arm -Hose Drape -Drop Arm Umbilical arms will be mounted to Mobile Launch Platform. SLS currently has 9 T-0 umbilical arms. The compliance refers to the ability of the umbilical to adjust to minor changes in vehicle location. The compliance mechanism refers to the mechanism on the ground support equipment {GSE) that compensates for these changes. For the CSITU, these minor changes, or vehicle excursions, can be up to +4 in. Excursions refer to movements of the vehicle caused by wind loads and thermal expansion. It is ideal to have significant vertical compliance so a passive secondary release mechanism may be implemented.
A traffic data plan for mechanistic-empirical pavement designs (2002 pavement design guide).
DOT National Transportation Integrated Search
2003-01-01
The Virginia Department of Transportation (VDOT) is preparing to implement the mechanistic-empirical pavement design methodology being developed under the National Cooperative Research Program's Project 1-37A, commonly referred to as the 2002 Pavemen...
ERIC Educational Resources Information Center
Bopp, Richard E., Ed.; Smith, Linda C., Ed.
Like the first two editions, this third edition is designed primarily to provide the beginning student of library and information science with an overview both of the concepts and processes behind today's reference services and of the most important sources consulted in answering common types of reference questions. The first 12 chapters deal with…
Sports Fields: A Manual for Design Construction and Maintenance.
ERIC Educational Resources Information Center
Puhalla, Jim; Krans, Jeff; Goatley, Mike
Comprehensive technical reference information is provided for those responsible for the design, construction, renovation, or maintenance of sports grounds. Chapters illustrate specific design elements of all popular sports facilities, and explain how those elements are integrated in a successful project; explore commonly encountered sports field…
Research on Basic Design Education: An International Survey
ERIC Educational Resources Information Center
Boucharenc, C. G.
2006-01-01
This paper reports on the results of a survey and qualitative analysis on the teaching of "Basic Design" in schools of design and architecture located in 22 countries. In the context of this research work, Basic Design means the teaching and learning of design fundamentals that may also be commonly referred to as the Principles of Two- and…
Human Exploration of Mars Design Reference Architecture 5.0
NASA Technical Reports Server (NTRS)
Drake, Bret G.
2010-01-01
This paper provides a summary of the Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.
Reference Avionics Architecture for Lunar Surface Systems
NASA Technical Reports Server (NTRS)
Somervill, Kevin M.; Lapin, Jonathan C.; Schmidt, Oron L.
2010-01-01
Developing and delivering infrastructure capable of supporting long-term manned operations to the lunar surface has been a primary objective of the Constellation Program in the Exploration Systems Mission Directorate. Several concepts have been developed related to development and deployment lunar exploration vehicles and assets that provide critical functionality such as transportation, habitation, and communication, to name a few. Together, these systems perform complex safety-critical functions, largely dependent on avionics for control and behavior of system functions. These functions are implemented using interchangeable, modular avionics designed for lunar transit and lunar surface deployment. Systems are optimized towards reuse and commonality of form and interface and can be configured via software or component integration for special purpose applications. There are two core concepts in the reference avionics architecture described in this report. The first concept uses distributed, smart systems to manage complexity, simplify integration, and facilitate commonality. The second core concept is to employ extensive commonality between elements and subsystems. These two concepts are used in the context of developing reference designs for many lunar surface exploration vehicles and elements. These concepts are repeated constantly as architectural patterns in a conceptual architectural framework. This report describes the use of these architectural patterns in a reference avionics architecture for Lunar surface systems elements.
Common mode noise rejection properties of amplitude and phase noise in a heterodyne interferometer.
Hechenblaikner, Gerald
2013-05-01
High precision metrology systems based on heterodyne interferometry can measure the position and attitude of objects to accuracies of picometer and nanorad, respectively. A frequently found feature of the general system design is the subtraction of a reference phase from the phase of the position interferometer, which suppresses low frequency common mode amplitude and phase fluctuations occurring in volatile optical path sections shared by both the position and reference interferometer. Spectral components of the noise at frequencies around or higher than the heterodyne frequency, however, are generally transmitted into the measurement band and may limit the measurement accuracy. Detailed analytical calculations complemented with Monte Carlo simulations show that high frequency noise components may also be entirely suppressed, depending on the relative difference of measurement and reference phase, which may be exploited by corresponding design provisions. While these results are applicable to any heterodyne interferometer with certain design characteristics, specific calculations and related discussions are given for the example of the optical metrology system of the LISA Pathfinder mission to space.
Brown, Alisa; Uneri, Ali; Silva, Tharindu De; Manbachi, Amir; Siewerdsen, Jeffrey H
2018-04-01
Dynamic reference frames (DRFs) are a common component of modern surgical tracking systems; however, the limited number of commercially available DRFs poses a constraint in developing systems, especially for research and education. This work presents the design and validation of a large, open-source library of DRFs compatible with passive, single-face tracking systems, such as Polaris stereoscopic infrared trackers (NDI, Waterloo, Ontario). An algorithm was developed to create new DRF designs consistent with intra- and intertool design constraints and convert to computer-aided design (CAD) files suitable for three-dimensional printing. A library of 10 such groups, each with 6 to 10 DRFs, was produced and tracking performance was validated in comparison to a standard commercially available reference, including pivot calibration, fiducial registration error (FRE), and target registration error (TRE). Pivot tests showed calibration error [Formula: see text], indistinguishable from the reference. FRE was [Formula: see text], and TRE in a CT head phantom was [Formula: see text], both equivalent to the reference. The library of DRFs offers a useful resource for surgical navigation research and could be extended to other tracking systems and alternative design constraints.
DOT National Transportation Integrated Search
1998-05-01
State transportation agencies commonly use consultant firms for some of their highway and bridge design. For example, the Louisiana Department of Transportation and Development (hereafter referred to as the "Department" or "LaDOTD") currently uses bo...
Human Exploration of Mars Design Reference Architecture 5.0
NASA Technical Reports Server (NTRS)
Drake, Bret G.; Hoffman, Stephen J.; Beaty, David W.
2009-01-01
This paper provides a summary of the 2007 Mars Design Reference Architecture 5.0 (DRA 5.0), which is the latest in a series of NASA Mars reference missions. It provides a vision of one potential approach to human Mars exploration including how Constellation systems can be used. The reference architecture provides a common framework for future planning of systems concepts, technology development, and operational testing as well as Mars robotic missions, research that is conducted on the International Space Station, and future lunar exploration missions. This summary the Mars DRA 5.0 provides an overview of the overall mission approach, surface strategy and exploration goals, as well as the key systems and challenges for the first three human missions to Mars.
A Field Guide to Kentucky Lakes and Wetlands.
ERIC Educational Resources Information Center
Kentucky State Div. of Water, Frankfort. Kentucky Natural Resources and Environmental Protection Cabinet.
Lakes and wetlands make up that part of Kentucky's water bodies commonly referred to as standing waters. These waters serve many purposes for the people of the state and are necessary and valued elements of its natural resources. This field guide was designed to provide useful background information and reference material for the study of these…
Designs and methods used in published Australian health promotion evaluations 1992-2011.
Chambers, Alana Hulme; Murphy, Kylie; Kolbe, Anthony
2015-06-01
To describe the designs and methods used in published Australian health promotion evaluation articles between 1992 and 2011. Using a content analysis approach, we reviewed 157 articles to analyse patterns and trends in designs and methods in Australian health promotion evaluation articles. The purpose was to provide empirical evidence about the types of designs and methods used. The most common type of evaluation conducted was impact evaluation. Quantitative designs were used exclusively in more than half of the articles analysed. Almost half the evaluations utilised only one data collection method. Surveys were the most common data collection method used. Few articles referred explicitly to an intended evaluation outcome or benefit and references to published evaluation models or frameworks were rare. This is the first time Australian-published health promotion evaluation articles have been empirically investigated in relation to designs and methods. There appears to be little change in the purposes, overall designs and methods of published evaluations since 1992. More methodologically transparent and sophisticated published evaluation articles might be instructional, and even motivational, for improving evaluation practice and result in better public health interventions and outcomes. © 2015 Public Health Association of Australia.
40 CFR 1065.330 - Exhaust-flow calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CONTROLS ENGINE-TESTING PROCEDURES Calibrations and Verifications Flow-Related Measurements § 1065.330... use other reference meters such as laminar flow elements, which are not commonly designed to withstand...
General Systems Theory and Instructional Systems Design.
ERIC Educational Resources Information Center
Salisbury, David F.
1990-01-01
Describes basic concepts in the field of general systems theory (GST) and identifies commonalities that exist between GST and instructional systems design (ISD). Models and diagrams that depict system elements in ISD are presented, and two matrices that show how GST has been used in ISD literature are included. (11 references) (LRW)
Arts Education Facilities Planner for Grades K-8.
ERIC Educational Resources Information Center
North Carolina State Dept. of Public Instruction, Raleigh.
This reference document for public school facility designers addresses arts education programs and the facilities that support them. Some sections focus on concepts and features common to most or all arts education subject areas, such as sound management, acoustical design, teacher workstations, and performance facilities. Other sections describe…
Learning Visual Design through Hypermedia: Pathways to Visual Literacy.
ERIC Educational Resources Information Center
Lockee, Barbara; Hergert, Tom
The interactive multimedia application described here attempts to provide learners and teachers with a common frame of reference for communicating about visual media. The system is based on a list of concepts related to composition, and illustrates those concepts with photographs, paintings, graphic designs, and motion picture scenes. The ability…
Code of Federal Regulations, 2011 CFR
2011-04-01
... planning and design of highways approved pursuant to title 23 U.S.C. § 772.3 Noise standards. The highway... exceed the highway agency's reasonableness design goal. Common Noise Environment. A group of receptors... Impact (FONSI), or the Record of Decision (ROD), as defined in 23 CFR part 771. Design year. The future...
Common path endoscopic probes for optical coherence tomography (Conference Presentation)
NASA Astrophysics Data System (ADS)
Singh, Kanwarpal; Gardecki, Joseph A.; Tearney, Guillermo J.
2017-02-01
Background: Dispersion imbalance and polarization mismatch between the reference and sample arm signals can lead to image quality degradation in optical coherence tomography (OCT). One approach to reduce these image artifacts is to employ a common-path geometry in fiber-based probes. In this work, we report an 800 um diameter all-fiber common-path monolithic probe for coronary artery imaging where the reference signal is generated using an inline fiber partial reflector. Methods: Our common-path probe was designed for swept-source based Fourier domain OCT at 1310 nm wavelength. A face of a coreless fiber was coated with gold and spliced to a standard SMF-28 single mode fiber creating an inline partial reflector, which acted as a reference surface. The other face of the coreless fiber was shaped into a ball lens for focusing. The optical elements were assembled within a 560 µm diameter drive shaft, which was attached to a rotary junction. The drive shaft was placed inside a transparent sheath having an outer diameter of 800 µm. Results: With a source input power of 30mW, the inline common-path probe achieved a sensitivity of 104 dB. Images of human finger skin showed the characteristic layers of skin as well as features such as sweat ducts. Images of coronary arteries ex vivo obtained with this probe enabled visualization of the characteristic architectural morphology of the normal artery wall and known features of atherosclerotic plaque. Conclusion: In this work, we have demonstrated a common path OCT probe for cardiovascular imaging. The probe is easy to fabricate, will reduce system complexity and overall cost. We believe that this design will be helpful in endoscopic applications that require high resolution and a compact form factor.
Getting on Top of Idiomatic Verbs. Tausend Wendungen im Kontext.
ERIC Educational Resources Information Center
Breitkreuz, Hartmut; Bosewitz, Rene
English idioms are catalogued for German speakers. The guide is designed to be used both as a reference and as a teaching tool. It is divided into sections, each listing and defining common idioms using a number of English verbs, then presenting them in the context of dialogues. Most sections contain idioms for six or seven more common verbs, then…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
... non-air quality health and environmental impacts) and are commonly referred to as maximum achievable... process, stack, storage, or fugitive emissions point, (D) are design, equipment, work practice, or... combination of the above. CAA section 112(d)(2)(A)-(E). The MACT standard may take the form of a design...
Designing a Task Based Curriculum for Intensive Language Training
ERIC Educational Resources Information Center
Elshoff, Joost
2014-01-01
In this paper, I will report on the progress made in designing a curriculum for intensive language training, in which one-on-one instruction is combined with online exercises and drills to achieve an optimal blend of expertise and technology enhanced language learning. The Common European Framework of Reference (CEFR) has become a crucial tool for…
Singh, Kanwarpal; Reddy, Rohith; Sharma, Gargi; Verma, Yogesh; Gardecki, Joseph A; Tearney, Guillermo
2018-03-01
Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Maris, E.; Froelich, D.
The designers of products subject to the European regulations on waste have an obligation to improve the recyclability of their products from the very first design stages. The statutory texts refer to ISO standard 22 628, which proposes a method to calculate vehicle recyclability. There are several scientific studies that propose other calculation methods as well. Yet the feedback from the CREER club, a group of manufacturers and suppliers expert in ecodesign and recycling, is that the product recyclability calculation method proposed in this standard is not satisfactory, since only a mass indicator is used, the calculation scope is not clearly defined, and common data on the recycling industry does not exist to allow comparable calculations to be made for different products. For these reasons, it is difficult for manufacturers to have access to a method and common data for calculation purposes.
The Impact of Artillery Precision Munitions on Army Strategic Objectives
2006-06-16
Copperhead.3 Commonly referred to as the artilleryman’s sniper round during development, the Copperhead requires the continuous laser designation of...a target from an observer. These lasers allow the round to “seek” only its programmed code designation. While the Copperhead can engage both...capability to identify laser designations. The Copperhead’s ability to function accurately is also subject to the weather. If clouds, fog, or
STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.
McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L
2016-01-01
The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.
ERIC Educational Resources Information Center
Crossman, Katie; Pinchbeck, Geoffrey
2012-01-01
Immigrants and the children of immigrants who have completed their schooling in Canadian school settings, commonly referred to as Generation 1.5, are increasingly identified in the research literature as academically at risk due to inadequately developed academic language proficiency and learning strategies. This article describes the design,…
40 CFR 80.598 - What are the designation requirements for refiners, importers, and distributors?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (MVNRLM) diesel fuel. (B) Heating oil. (C) Jet fuel. (D) Kerosene. (E) No. 4 fuel. (F) Distillate fuel for... for use as kerosene or jet fuel (i.e., commonly referred to as dual use kerosene) may be designated as MVNRLM, kerosene, or jet fuel (as applicable). (viii) Beginning June 1, 2007, any distillate fuel with a...
40 CFR 80.598 - What are the designation requirements for refiners, importers, and distributors?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (MVNRLM) diesel fuel. (B) Heating oil. (C) Jet fuel. (D) Kerosene. (E) No. 4 fuel. (F) Distillate fuel for... for use as kerosene or jet fuel (i.e., commonly referred to as dual use kerosene) may be designated as MVNRLM, kerosene, or jet fuel (as applicable). (viii) Beginning June 1, 2007, any distillate fuel with a...
40 CFR 80.598 - What are the designation requirements for refiners, importers, and distributors?
Code of Federal Regulations, 2012 CFR
2012-07-01
... (MVNRLM) diesel fuel. (B) Heating oil. (C) Jet fuel. (D) Kerosene. (E) No. 4 fuel. (F) Distillate fuel for... for use as kerosene or jet fuel (i.e., commonly referred to as dual use kerosene) may be designated as MVNRLM, kerosene, or jet fuel (as applicable). (viii) Beginning June 1, 2007, any distillate fuel with a...
40 CFR 80.598 - What are the designation requirements for refiners, importers, and distributors?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (MVNRLM) diesel fuel. (B) Heating oil. (C) Jet fuel. (D) Kerosene. (E) No. 4 fuel. (F) Distillate fuel for... for use as kerosene or jet fuel (i.e., commonly referred to as dual use kerosene) may be designated as MVNRLM, kerosene, or jet fuel (as applicable). (viii) Beginning June 1, 2007, any distillate fuel with a...
40 CFR 80.598 - What are the designation requirements for refiners, importers, and distributors?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (MVNRLM) diesel fuel. (B) Heating oil. (C) Jet fuel. (D) Kerosene. (E) No. 4 fuel. (F) Distillate fuel for... for use as kerosene or jet fuel (i.e., commonly referred to as dual use kerosene) may be designated as MVNRLM, kerosene, or jet fuel (as applicable). (viii) Beginning June 1, 2007, any distillate fuel with a...
Research the mobile phone operation interfaces for vision-impairment.
Yao, Yen-Ting; Leung, Cherng-Yee
2012-01-01
Due to the vision-impaired users commonly having difficulty with mobile-phone function operations and adaption any manufacturer's user interface design, the goals for this research are established for evaluating how to improve for them the function operation convenience and user interfaces of either mobile phones or electronic appliances in the market currently. After applying collecting back 30 effective questionnaires from 30 vision-impairment, the comments have been concluded from this research include: (1) All mobile phone manufactures commonly ignorant of the vision-impairment difficulty with operating mobile phone user interfaces; (2) The vision-impairment preferential with audio alert signals; (3) The vision-impairment incapable of mobile-phone procurement independently unless with assistance from others; (4) Preferential with adding touch-usage interface design by the vision-impairment; in contrast with the least requirement for such functions as braille, enlarging keystroke size and diversifying-function control panel. With exploring the vision-impairment's necessary improvements and obstacles for mobile phone interface operation, this research is established with goals for offering reference possibly applied in electronic appliance design and . Hopefully, the analysis results of this research could be used as data references for designing electronic and high-tech products and promoting more usage convenience for those vision-impaired.
Design of a diagnostic encyclopaedia using AIDA.
van Ginneken, A M; Smeulders, A W; Jansen, W
1987-01-01
Diagnostic Encyclopaedia Workstation (DEW) is the name of a digital encyclopaedia constructed to contain reference knowledge with respect to the pathology of the ovary. Comparing DEW with the common sources of reference knowledge (i.e. books) leads to the following advantages of DEW: it contains more verbal knowledge, pictures and case histories, and it offers information adjusted to the needs of the user. Based on an analysis of the structure of this reference knowledge we have chosen AIDA to develop a relational database and we use a video-disc player to contain the pictorial part of the database. The system consists of a database input version and a read-only run version. The design of the database input version is discussed. Reference knowledge for ovary pathology requires 1-3 Mbytes of memory. At present 15% of this amount is available. The design of the run version is based on an analysis of which information must necessarily be specified to the system by the user to access a desired item of information. Finally, the use of AIDA in constructing DEW is evaluated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Badwan, Faris M.; Demuth, Scott Francis; Miller, Michael Conrad
Small Modular Reactors (SMR) with power levels significantly less than the currently standard 1000 to 1600-MWe reactors have been proposed as a potential game changer for future nuclear power. SMRs may offer a simpler, more standardized, and safer modular design by using factory built and easily transportable components. Additionally, SMRs may be more easily built and operated in isolated locations, and may require smaller initial capital investment and shorter construction times. Because many SMRs designs are still conceptual and consequently not yet fixed, designers have a unique opportunity to incorporate updated design basis threats, emergency preparedness requirements, and then fullymore » integrate safety, physical security, and safeguards/material control and accounting (MC&A) designs. Integrating safety, physical security, and safeguards is often referred to as integrating the 3Ss, and early consideration of safeguards and security in the design is often referred to as safeguards and security by design (SSBD). This paper describes U.S./Russian collaborative efforts toward developing an internationally accepted common approach for implementing SSBD/3Ss for SMRs based upon domestic requirements, and international guidance and requirements. These collaborative efforts originated with the Nuclear Energy and Nuclear Security working group established under the U.S.-Russia Bilateral Presidential Commission during the 2009 Presidential Summit. Initial efforts have focused on review of U.S. and Russian domestic requirements for Security and MC&A, IAEA guidance for security and MC&A, and IAEA requirements for international safeguards. Additionally, example SMR design features that can enhance proliferation resistance and physical security have been collected from past work and reported here. The development of a U.S./Russian common approach for SSBD/3Ss should aid the designer of SMRs located anywhere in the world. More specifically, the application of this approach may lead to more proliferation resistant and physically secure design features for SMRs.« less
NASA Technical Reports Server (NTRS)
1973-01-01
The design specifications for the programs and modules within the NASA Aerospace Safety Information System (NASIS) are presented. The purpose of the design specifications is to standardize the preparation of the specifications and to guide the program design. Each major functional module within the system is a separate entity for documentation purposes. The design specifications contain a description of, and specifications for, all detail processing which occurs in the module. Sub-modules, reference tables, and data sets which are common to several modules are documented separately.
NASA Technical Reports Server (NTRS)
1973-01-01
The design specifications for the programs and modules within the NASA Aerospace Safety Information System (NASIS) are presented. The purpose of the design specifications is to standardize the preparation of the specifications and to guide the program design. Each major functional module within the system is a separate entity for documentation purposes. The design specifications contain a description of, and specifications for, all detail processing which occurs in the module. Sub-models, reference tables, and data sets which are common to several modules are documented separately.
Leadership Academies: Elixir for Common School Ills.
ERIC Educational Resources Information Center
School Administrator, 1989
1989-01-01
Describes a model leadership academy program at Topeka (Kansas) Public Schools in cooperation with Kansas State University. Created in 1987, the academy was designed to serve the school system's unique needs while fostering innovative educational experiences for administrator preparation. Includes four references. (MLH)
DOT National Transportation Integrated Search
2014-01-01
The Maine Department of Transportation (MaineDOT) has noted poor correlation between predicted pile resistances : calculated using commonly accepted design methods and measured pile resistance from dynamic pile load tests (also : referred to as high ...
DOT National Transportation Integrated Search
2014-01-01
The Maine Department of Transportation (MaineDOT) has noted poor correlation between predicted pile resistances : calculated using commonly accepted design methods and measured pile resistance from dynamic pile load tests (also : referred to as high ...
Alternatives for discounting in the analysis of noninferiority trials.
Snapinn, Steven M
2004-05-01
Determining the efficacy of an experimental therapy relative to placebo on the basis of an active-control noninferiority trial requires reference to historical placebo-controlled trials. The validity of the resulting comparison depends on two key assumptions: assay sensitivity and constancy. Since the truth of these assumptions cannot be verified, it seems logical to raise the standard of evidence required to declare efficacy; this concept is referred to as discounting. It is not often recognized that two common design and analysis approaches, setting a noninferiority margin and requiring preservation of a fraction of the standard therapy's effect, are forms of discounting. The noninferiority margin is a particularly poor approach, since its degree of discounting depends on an irrelevant factor. Preservation of effect is more reasonable, but it addresses only the constancy assumption, not the issue of assay sensitivity. Gaining consensus on the most appropriate approach to the design and analysis of noninferiority trials will require a common understanding of the concept of discounting.
Penley, Stephanie C; Gaudet, Cynthia M; Threlkeld, Steven W
2013-12-04
Working and reference memory are commonly assessed using the land based radial arm maze. However, this paradigm requires pretraining, food deprivation, and may introduce scent cue confounds. The eight-arm radial water maze is designed to evaluate reference and working memory performance simultaneously by requiring subjects to use extra-maze cues to locate escape platforms and remedies the limitations observed in land based radial arm maze designs. Specifically, subjects are required to avoid the arms previously used for escape during each testing day (working memory) as well as avoid the fixed arms, which never contain escape platforms (reference memory). Re-entries into arms that have already been used for escape during a testing session (and thus the escape platform has been removed) and re-entries into reference memory arms are indicative of working memory deficits. Alternatively, first entries into reference memory arms are indicative of reference memory deficits. We used this maze to compare performance of rats with neonatal brain injury and sham controls following induction of hypoxia-ischemia and show significant deficits in both working and reference memory after eleven days of testing. This protocol could be easily modified to examine many other models of learning impairment.
A Reference Architecture for Space Information Management
NASA Technical Reports Server (NTRS)
Mattmann, Chris A.; Crichton, Daniel J.; Hughes, J. Steven; Ramirez, Paul M.; Berrios, Daniel C.
2006-01-01
We describe a reference architecture for space information management systems that elegantly overcomes the rigid design of common information systems in many domains. The reference architecture consists of a set of flexible, reusable, independent models and software components that function in unison, but remain separately managed entities. The main guiding principle of the reference architecture is to separate the various models of information (e.g., data, metadata, etc.) from implemented system code, allowing each to evolve independently. System modularity, systems interoperability, and dynamic evolution of information system components are the primary benefits of the design of the architecture. The architecture requires the use of information models that are substantially more advanced than those used by the vast majority of information systems. These models are more expressive and can be more easily modularized, distributed and maintained than simpler models e.g., configuration files and data dictionaries. Our current work focuses on formalizing the architecture within a CCSDS Green Book and evaluating the architecture within the context of the C3I initiative.
Issues and Design Drivers for Deep Space Habitats
NASA Technical Reports Server (NTRS)
Rucker, Michelle A.; Anderson, Molly
2012-01-01
A cross-disciplinary team of scientists and engineers applied expertise gained in Lunar Lander development to the conceptual design of a long-duration, deep space habitat for Near Earth Asteroid (NEA) missions. The design reference mission involved two launches to assemble 5-modules for a 380-day round trip mission carrying 4 crew members. The conceptual design process yielded a number of interesting debates, some of which could be significant design drivers in a detailed Deep Space Habitat (DSH) design. These issues included: Design to minimize crew radiation exposure, launch loads, communications challenges, docking system and hatch commonality, pointing and visibility, consumables, and design for contingency operations.
State reference design and saturated control of doubly-fed induction generators under voltage dips
NASA Astrophysics Data System (ADS)
Tilli, Andrea; Conficoni, Christian; Hashemi, Ahmad
2017-04-01
In this paper, the stator/rotor currents control problem of doubly-fed induction generator under faulty line voltage is carried out. Common grid faults cause a steep decline in the line voltage profile, commonly denoted as voltage dip. This point is critical for such kind of machines, having their stator windings directly connected to the grid. In this respect, solid methodological nonlinear control theory arguments are exploited and applied to design a novel controller, whose main goal is to improve the system behaviour during voltage dips, endowing it with low voltage ride through capability, a fundamental feature required by modern Grid Codes. The proposed solution exploits both feedforward and feedback actions. The feedforward part relies on suitable reference trajectories for the system internal dynamics, which are designed to prevent large oscillations in the rotor currents and command voltages, excited by line perturbations. The feedback part uses state measurements and is designed according to Linear Matrix Inequalities (LMI) based saturated control techniques to further reduce oscillations, while explicitly accounting for the system constraints. Numerical simulations verify the benefits of the internal dynamics trajectory planning, and the saturated state feedback action, in crucially improving the Doubly-Fed Induction Machine response under severe grid faults.
Biological Diversity. Global Issues Education Packet.
ERIC Educational Resources Information Center
Holm, Amy E.
Biological diversity, also commonly called genetic diversity, refers to the variety of organisms on Earth. Scientists are concerned that many species will become extinct because of extensive development in the tropical regions. This packet is designed to increase student's awareness about direct and indirect causes of extinction, endangered…
Organic crop production's top research priority: Pestiphytology
USDA-ARS?s Scientific Manuscript database
Pestiphytology is the study of pest plants, commonly referred to as weeds. In a recent national survey, weed research was designated as the top research priority by organic producers. Manual weed control is a costly practice that can quickly decrease return on investment, while the absence of weed...
Identification and evaluation of reference genes for qRT-PCR normalization in Ganoderma lucidum.
Xu, Jiang; Xu, ZhiChao; Zhu, YingJie; Luo, HongMei; Qian, Jun; Ji, AiJia; Hu, YuanLei; Sun, Wei; Wang, Bo; Song, JingYuan; Sun, Chao; Chen, ShiLin
2014-01-01
Quantitative real-time reverse transcription PCR (qRT-PCR) is a rapid, sensitive, and reliable technique for gene expression studies. The accuracy and reliability of qRT-PCR results depend on the stability of the reference genes used for gene normalization. Therefore, a systematic process of reference gene evaluation is needed. Ganoderma lucidum is a famous medicinal mushroom in East Asia. In the current study, 10 potential reference genes were selected from the G. lucidum genomic data. The sequences of these genes were manually curated, and primers were designed following strict criteria. The experiment was conducted using qRT-PCR, and the stability of each candidate gene was assessed using four commonly used statistical programs-geNorm, NormFinder, BestKeeper, and RefFinder. According to our results, PP2A was expressed at the most stable levels under different fermentation conditions, and RPL4 was the most stably expressed gene in different tissues. RPL4, PP2A, and β-tubulin are the most commonly recommended reference genes for normalizing gene expression in the entire sample set. The current study provides a foundation for the further use of qRT-PCR in G. lucidum gene analysis.
Nelson, Sarah C.; Stilp, Adrienne M.; Papanicolaou, George J.; Taylor, Kent D.; Rotter, Jerome I.; Thornton, Timothy A.; Laurie, Cathy C.
2016-01-01
Imputation is commonly used in genome-wide association studies to expand the set of genetic variants available for analysis. Larger and more diverse reference panels, such as the final Phase 3 of the 1000 Genomes Project, hold promise for improving imputation accuracy in genetically diverse populations such as Hispanics/Latinos in the USA. Here, we sought to empirically evaluate imputation accuracy when imputing to a 1000 Genomes Phase 3 versus a Phase 1 reference, using participants from the Hispanic Community Health Study/Study of Latinos. Our assessments included calculating the correlation between imputed and observed allelic dosage in a subset of samples genotyped on a supplemental array. We observed that the Phase 3 reference yielded higher accuracy at rare variants, but that the two reference panels were comparable at common variants. At a sample level, the Phase 3 reference improved imputation accuracy in Hispanic/Latino samples from the Caribbean more than for Mainland samples, which we attribute primarily to the additional reference panel samples available in Phase 3. We conclude that a 1000 Genomes Project Phase 3 reference panel can yield improved imputation accuracy compared with Phase 1, particularly for rare variants and for samples of certain genetic ancestry compositions. Our findings can inform imputation design for other genome-wide association studies of participants with diverse ancestries, especially as larger and more diverse reference panels continue to become available. PMID:27346520
Design and Development of the SMAP Microwave Radiometer Electronics
NASA Technical Reports Server (NTRS)
Piepmeier, Jeffrey R.; Medeiros, James J.; Horgan, Kevin A.; Brambora, Clifford K.; Estep, Robert H.
2014-01-01
The SMAP microwave radiometer will measure land surface brightness temperature at L-band (1413 MHz) in the presence of radio frequency interference (RFI) for soil moisture remote sensing. The radiometer design was driven by the requirements to incorporate internal calibration, to operate synchronously with the SMAP radar, and to mitigate the deleterious effects of RFI. The system design includes a highly linear super-heterodyne microwave receiver with internal reference loads and noise sources for calibration and an innovative digital signal processor and detection system. The front-end comprises a coaxial cable-based feed network, with a pair of diplexers and a coupled noise source, and radiometer front-end (RFE) box. Internal calibration is provided by reference switches and a common noise source inside the RFE. The RF back-end (RBE) downconverts the 1413 MHz channel to an intermediate frequency (IF) of 120 MHz. The IF signals are then sampled and quantized by high-speed analog-to-digital converters in the radiometer digital electronics (RDE) box. The RBE local oscillator and RDE sampling clocks are phase-locked to a common reference to ensure coherency between the signals. The RDE performs additional filtering, sub-band channelization, cross-correlation for measuring third and fourth Stokes parameters, and detection and integration of the first four raw moments of the signals. These data are packetized and sent to the ground for calibration and further processing. Here we discuss the novel features of the radiometer hardware particularly those influenced by the need to mitigate RFI.
16 CFR 305.3 - Description of covered products.
Code of Federal Regulations, 2010 CFR
2010-01-01
... discharge into light, including only the following: (i) Any straight-shaped lamp (commonly referred to as 4... OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ... refrigerator means a cabinet designed for the refrigerated storage of food at temperatures above 32 °F and...
Fundamentals of Athletic Training. Second Edition.
ERIC Educational Resources Information Center
Behling, Fred L.; And Others
This book provides an authoritative reference on the fundamentals of athletic training for people with varied backgrounds but a common interest in the health and education of the high school athlete. The book is designed especially for the novice athletic trainer. Section 1 of the book concerns the organization and administration of athletic…
A Measurement Model of Microgenetic Transfer for Improving Instructional Outcomes
ERIC Educational Resources Information Center
Pavlik, Philip I., Jr.; Yudelson, Michael; Koedinger, Kenneth R.
2015-01-01
Efforts to improve instructional task design often make reference to the mental structures, such as "schemas" (e.g., Gick & Holyoak, 1983) or "identical elements" (Thorndike & Woodworth, 1901), that are common to both the instructional and target tasks. This component based (e.g., Singley & Anderson, 1989) approach…
Rep. Hall, John J. [D-NY-19
2010-07-30
House - 09/20/2010 Referred to the Subcommittee on the Constitution, Civil Rights, and Civil Liberties. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Code of Federal Regulations, 2012 CFR
2012-01-01
... identical water-passage design features that use the same path of water in the highest flow mode. Batch... as 8-foot high output lamps) with recessed double contact bases of nominal overall length of 96... (commonly referred to 4-foot miniature bipin high output lamps) with miniature bipin bases of nominal...
DOT National Transportation Integrated Search
2017-12-01
When Portland cement concrete (PCC) pavement reaches an intolerable level of service, it is commonly overlaid with asphaltic concrete (AC) and is referred to as a composite pavement. Even though AC overlays are designed to resist failure mechanisms s...
Measurement of aspheric mirror segments using Fizeau interferometry with CGH correction
NASA Astrophysics Data System (ADS)
Burge, James H.; Zhao, Chunyu; Dubin, Matt
2010-07-01
Large aspheric primary mirrors are proposed that use hundreds segments that all must be aligned and phased to approximate the desired continuous mirror. We present a method of measuring these concave segments with a Fizeau interferometer where a spherical convex reference surface is held a few millimeters from the aspheric segment. The aspheric shape is accommodated by a small computer generated hologram (CGH). Different segments are measured by replacing the CGH. As a Fizeau test, nearly all of the optical elements and air spaces are common to both the measurement and reference wavefront, so the sensitivities are not tight. Also, since the reference surface of the test plate is common to all tests, this system achieves excellent control for the radius of curvature variation from one part to another. This paper describes the test system design and analysis for such a test, and presents data from a similar 1.4-m test performed at the University of Arizona.
Adaptive nonlinear control for autonomous ground vehicles
NASA Astrophysics Data System (ADS)
Black, William S.
We present the background and motivation for ground vehicle autonomy, and focus on uses for space-exploration. Using a simple design example of an autonomous ground vehicle we derive the equations of motion. After providing the mathematical background for nonlinear systems and control we present two common methods for exactly linearizing nonlinear systems, feedback linearization and backstepping. We use these in combination with three adaptive control methods: model reference adaptive control, adaptive sliding mode control, and extremum-seeking model reference adaptive control. We show the performances of each combination through several simulation results. We then consider disturbances in the system, and design nonlinear disturbance observers for both single-input-single-output and multi-input-multi-output systems. Finally, we show the performance of these observers with simulation results.
Strategies and arguments of ergonomic design for sustainability.
Marano, Antonio; Di Bucchianico, Giuseppe; Rossi, Emilio
2012-01-01
Referring to the discussion recently promoted by the Sub-Technical Committee n°4 "Ergonomics and design for sustainability", in this paper will be shown the early results of a theoretical and methodological study on Ergonomic design for sustainability. In particular, the research is based on the comparison between the common thematic structure characterizing Ergonomics, with the principles of Sustainable Development and with criteria adopted from other disciplines already oriented toward Sustainability. The paper identifies an early logical-interpretative model and describes possible and relevant Strategies of Ergonomic design for sustainability, which are connected in a series of specific Sustainable Arguments.
Tumlinson, Samuel E; Sass, Daniel A; Cano, Stephanie M
2014-03-01
While experimental designs are regarded as the gold standard for establishing causal relationships, such designs are usually impractical owing to common methodological limitations. The objective of this article is to illustrate how propensity score matching (PSM) and using propensity scores (PS) as a covariate are viable alternatives to reduce estimation error when experimental designs cannot be implemented. To mimic common pediatric research practices, data from 140 simulated participants were used to resemble an experimental and nonexperimental design that assessed the effect of treatment status on participant weight loss for diabetes. Pretreatment participant characteristics (age, gender, physical activity, etc.) were then used to generate PS for use in the various statistical approaches. Results demonstrate how PSM and using the PS as a covariate can be used to reduce estimation error and improve statistical inferences. References for issues related to the implementation of these procedures are provided to assist researchers.
Advanced Extended Plate and Beam Wall System in a Cold-Climate House
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, Dave; Wiehagen, Joseph; Kochkin, Vladimir
This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.
A reference model for model-based design of critical infrastructure protection systems
NASA Astrophysics Data System (ADS)
Shin, Young Don; Park, Cheol Young; Lee, Jae-Chon
2015-05-01
Today's war field environment is getting versatile as the activities of unconventional wars such as terrorist attacks and cyber-attacks have noticeably increased lately. The damage caused by such unconventional wars has also turned out to be serious particularly if targets are critical infrastructures that are constructed in support of banking and finance, transportation, power, information and communication, government, and so on. The critical infrastructures are usually interconnected to each other and thus are very vulnerable to attack. As such, to ensure the security of critical infrastructures is very important and thus the concept of critical infrastructure protection (CIP) has come. The program to realize the CIP at national level becomes the form of statute in each country. On the other hand, it is also needed to protect each individual critical infrastructure. The objective of this paper is to study on an effort to do so, which can be called the CIP system (CIPS). There could be a variety of ways to design CIPS's. Instead of considering the design of each individual CIPS, a reference model-based approach is taken in this paper. The reference model represents the design of all the CIPS's that have many design elements in common. In addition, the development of the reference model is also carried out using a variety of model diagrams. The modeling language used therein is the systems modeling language (SysML), which was developed and is managed by Object Management Group (OMG) and a de facto standard. Using SysML, the structure and operational concept of the reference model are designed to fulfil the goal of CIPS's, resulting in the block definition and activity diagrams. As a case study, the operational scenario of the nuclear power plant while being attacked by terrorists is studied using the reference model. The effectiveness of the results is also analyzed using multiple analysis models. It is thus expected that the approach taken here has some merits over the traditional design methodology of repeating requirements analysis and system design.
Integrating common and rare genetic variation in diverse human populations.
Altshuler, David M; Gibbs, Richard A; Peltonen, Leena; Altshuler, David M; Gibbs, Richard A; Peltonen, Leena; Dermitzakis, Emmanouil; Schaffner, Stephen F; Yu, Fuli; Peltonen, Leena; Dermitzakis, Emmanouil; Bonnen, Penelope E; Altshuler, David M; Gibbs, Richard A; de Bakker, Paul I W; Deloukas, Panos; Gabriel, Stacey B; Gwilliam, Rhian; Hunt, Sarah; Inouye, Michael; Jia, Xiaoming; Palotie, Aarno; Parkin, Melissa; Whittaker, Pamela; Yu, Fuli; Chang, Kyle; Hawes, Alicia; Lewis, Lora R; Ren, Yanru; Wheeler, David; Gibbs, Richard A; Muzny, Donna Marie; Barnes, Chris; Darvishi, Katayoon; Hurles, Matthew; Korn, Joshua M; Kristiansson, Kati; Lee, Charles; McCarrol, Steven A; Nemesh, James; Dermitzakis, Emmanouil; Keinan, Alon; Montgomery, Stephen B; Pollack, Samuela; Price, Alkes L; Soranzo, Nicole; Bonnen, Penelope E; Gibbs, Richard A; Gonzaga-Jauregui, Claudia; Keinan, Alon; Price, Alkes L; Yu, Fuli; Anttila, Verneri; Brodeur, Wendy; Daly, Mark J; Leslie, Stephen; McVean, Gil; Moutsianas, Loukas; Nguyen, Huy; Schaffner, Stephen F; Zhang, Qingrun; Ghori, Mohammed J R; McGinnis, Ralph; McLaren, William; Pollack, Samuela; Price, Alkes L; Schaffner, Stephen F; Takeuchi, Fumihiko; Grossman, Sharon R; Shlyakhter, Ilya; Hostetter, Elizabeth B; Sabeti, Pardis C; Adebamowo, Clement A; Foster, Morris W; Gordon, Deborah R; Licinio, Julio; Manca, Maria Cristina; Marshall, Patricia A; Matsuda, Ichiro; Ngare, Duncan; Wang, Vivian Ota; Reddy, Deepa; Rotimi, Charles N; Royal, Charmaine D; Sharp, Richard R; Zeng, Changqing; Brooks, Lisa D; McEwen, Jean E
2010-09-02
Despite great progress in identifying genetic variants that influence human disease, most inherited risk remains unexplained. A more complete understanding requires genome-wide studies that fully examine less common alleles in populations with a wide range of ancestry. To inform the design and interpretation of such studies, we genotyped 1.6 million common single nucleotide polymorphisms (SNPs) in 1,184 reference individuals from 11 global populations, and sequenced ten 100-kilobase regions in 692 of these individuals. This integrated data set of common and rare alleles, called 'HapMap 3', includes both SNPs and copy number polymorphisms (CNPs). We characterized population-specific differences among low-frequency variants, measured the improvement in imputation accuracy afforded by the larger reference panel, especially in imputing SNPs with a minor allele frequency of
The ACP Special Issue is being organized to draw together analysis of a set of cooperative modeling experiments (referred to as HTAP2). The purpose of this technical note is to provide a common description of the experimental design and set up for HTAP2 that can be referred to b...
ERIC Educational Resources Information Center
Davis, Andrew S.; Moore, Brittney; Rice, Valerie; Decker, Scott
2015-01-01
Mild traumatic brain injury (mTBI), sometimes referred to as concussion, is one of the most common acquired neurological problems of childhood. When children return to school following mTBI, school psychologists should be actively involved in the determination of neurocognitive and functional deficits for the purpose of designing strength-based…
Design and Calibration of an Inexpensive Digital Anemometer
ERIC Educational Resources Information Center
Hernandez-Walls, R.; Rojas-Mayoral, E.; Baez-Castillo, L.; Rojas-Mayoral, B.
2008-01-01
An inexpensive and easily implemented device to measure wind velocity is proposed. This prototype has the advantage of being able to measure both the speed and the direction of the wind in two dimensions. The device utilizes a computational interface commonly referred to as a "mouse." The mouse proposed for this prototype contains an…
Human Capital Development: Comparative Analysis of BRICs
ERIC Educational Resources Information Center
Ardichvili, Alexandre; Zavyalova, Elena; Minina, Vera
2012-01-01
Purpose: The goal of this article is to conduct macro-level analysis of human capital (HC) development strategies, pursued by four countries commonly referred to as BRICs (Brazil, Russia, India, and China). Design/methodology/approach: This analysis is based on comparisons of macro indices of human capital and innovativeness of the economy and a…
ERIC Educational Resources Information Center
Coello-Coutino, Gerardo; Ainsworth, Shirley; Escalante-Gonzalbo, Ana Marie
2002-01-01
Describes Hermes, a research tool that uses specially designed acquisition, parsing and presentation methods to integrate information resources on the Internet, from searching in disparate bibliographic databases, to accessing full text articles online, and developing a web of information associated with each reference via one common interface.…
Pre-Service Teachers' Mindset Beliefs about Student Ability
ERIC Educational Resources Information Center
Gutshall, C. Anne
2014-01-01
Introduction: We all have beliefs about our ability or intelligence. The extent to which we believe ability is malleable (growth) or stable (fixed) is commonly referred to as our mindset. This research is designed to explore pre-service teachers' mindset beliefs as well as their beliefs when applied to hypothetical student scenarios. Method:…
ERIC Educational Resources Information Center
Peace Corps, Washington, DC.
This 7,000-word dictionary is designed for English speakers learning Dari. The dictionary consists of two parts, the first a reference to find words easily translatable from one language to the other, the second a list of idioms and short phrases commonly used in everyday conversation, yet not readily translatable. Many of these entries have no…
ERIC Educational Resources Information Center
Ziegler, Nicholas Allan
2014-01-01
The European Language Portfolio (ELP) is an alternative assessment used in foreign language classes throughout Europe to support and record language learning. Directly linked to the Common European Framework of Reference for Languages (Council of Europe, 2001) proficiency guidelines, it is designed to achieve an ambitious dual goal: document…
Dolphins. LC Science Tracer Bullet.
ERIC Educational Resources Information Center
Niskern, Diana, Comp.
The family Delphinidae is the largest family of toothed whales. It includes not only those mammals commonly referred to as dolphins, such as the bottlenosed dolphin often seen in captivity, but also the killer whale. This literature and resources guide is not intended to be a comprehensive bibliography on dolphins; the guide is designed--as the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knirsch, Fabian; Engel, Dominik; Neureiter, Christian
In a smart grid, data and information are transported, transmitted, stored, and processed with various stakeholders having to cooperate effectively. Furthermore, personal data is the key to many smart grid applications and therefore privacy impacts have to be taken into account. For an effective smart grid, well integrated solutions are crucial and for achieving a high degree of customer acceptance, privacy should already be considered at design time of the system. To assist system engineers in early design phase, frameworks for the automated privacy evaluation of use cases are important. For evaluation, use cases for services and software architectures needmore » to be formally captured in a standardized and commonly understood manner. In order to ensure this common understanding for all kinds of stakeholders, reference models have recently been developed. In this paper we present a model-driven approach for the automated assessment of such services and software architectures in the smart grid that builds on the standardized reference models. The focus of qualitative and quantitative evaluation is on privacy. For evaluation, the framework draws on use cases from the University of Southern California microgrid.« less
Guidelines and Capabilities for Designing Human Missions
NASA Technical Reports Server (NTRS)
2002-01-01
The human element is likely the most complex and difficult one of mission design; it significantly influences every aspect of mission planning, from the basic parameters like duration to the more complex tradeoffs between mass, volume, power, risk, and cost. For engineers who rely on precise specifications in data books and other such technical references, dealing with the uncertainty and the variability of designing for human beings can be frustrating. When designing for the human element, questions arise more often than definitive answers. Nonetheless, we do not doubt that the most captivating discoveries in future space missions will necessitate human explorers. These guidelines and capabilities are meant to identify the points of intersection between humans and mission considerations such as architecture, vehicle design, technologies, operations, and science requirements. We seek to provide clear, top-level guidelines for human-related exploration studies and technology research that address common questions and requirements. As a result, we hope that ongoing mission trade studies consider common, standard, and practical criteria for human interfaces.
Guidelines and Capabilities for Designing Human Missions
NASA Astrophysics Data System (ADS)
2002-03-01
The human element is likely the most complex and difficult one of mission design; it significantly influences every aspect of mission planning, from the basic parameters like duration to the more complex tradeoffs between mass, volume, power, risk, and cost. For engineers who rely on precise specifications in data books and other such technical references, dealing with the uncertainty and the variability of designing for human beings can be frustrating. When designing for the human element, questions arise more often than definitive answers. Nonetheless, we do not doubt that the most captivating discoveries in future space missions will necessitate human explorers. These guidelines and capabilities are meant to identify the points of intersection between humans and mission considerations such as architecture, vehicle design, technologies, operations, and science requirements. We seek to provide clear, top-level guidelines for human-related exploration studies and technology research that address common questions and requirements. As a result, we hope that ongoing mission trade studies consider common, standard, and practical criteria for human interfaces.
2010-01-01
Background The development of DNA microarrays has facilitated the generation of hundreds of thousands of transcriptomic datasets. The use of a common reference microarray design allows existing transcriptomic data to be readily compared and re-analysed in the light of new data, and the combination of this design with large datasets is ideal for 'systems'-level analyses. One issue is that these datasets are typically collected over many years and may be heterogeneous in nature, containing different microarray file formats and gene array layouts, dye-swaps, and showing varying scales of log2- ratios of expression between microarrays. Excellent software exists for the normalisation and analysis of microarray data but many data have yet to be analysed as existing methods struggle with heterogeneous datasets; options include normalising microarrays on an individual or experimental group basis. Our solution was to develop the Batch Anti-Banana Algorithm in R (BABAR) algorithm and software package which uses cyclic loess to normalise across the complete dataset. We have already used BABAR to analyse the function of Salmonella genes involved in the process of infection of mammalian cells. Results The only input required by BABAR is unprocessed GenePix or BlueFuse microarray data files. BABAR provides a combination of 'within' and 'between' microarray normalisation steps and diagnostic boxplots. When applied to a real heterogeneous dataset, BABAR normalised the dataset to produce a comparable scaling between the microarrays, with the microarray data in excellent agreement with RT-PCR analysis. When applied to a real non-heterogeneous dataset and a simulated dataset, BABAR's performance in identifying differentially expressed genes showed some benefits over standard techniques. Conclusions BABAR is an easy-to-use software tool, simplifying the simultaneous normalisation of heterogeneous two-colour common reference design cDNA microarray-based transcriptomic datasets. We show BABAR transforms real and simulated datasets to allow for the correct interpretation of these data, and is the ideal tool to facilitate the identification of differentially expressed genes or network inference analysis from transcriptomic datasets. PMID:20128918
2017-05-22
previous studies from proton on proton colli- sions and deuteron on gold nucleus collisions, as well as with model calculations, may provide deeper insight...designed to achieve target energies. Machines are also designed for different collision systems, such as Cu+Cu or Au+Au. This is one way to study ...charge states of delta baryons are minus one , zero, plus one , and plus two. For this project, we are studying the plus two charge state, commonly referred
Grass buffers for playas in agricultural landscapes: An annotated bibliography
Melcher, Cynthia P.; Skagen, Susan K.
2005-01-01
References on best management practices (BMPs) for agricultural lands were included because certain BMPs are crucial for informing decisions about buffer design/ effectiveness and overall playa ecology. We also included various papers that increase the spectrum of time over which buffer theories and practices have evolved. An unannotated section lists references that we did not prioritize for annotation and references that may be helpful but were beyond the scope of this document. Finally, we provide notes on conversations we had with scientists, land managers, and other buffer experts whom we consulted, and their contact information. We conclude the bibliography with appendices of common and scientific names of birds and plants and acronyms used in both the bibliography. In the annotations, italicized text signifies our own editorial remarks. Readers should also note that much of the work on buffers has been designed using English units of measure rather than metrics; in most cases, their results have been converted to metrics for publication, explaining the seemingly odd or irregular buffer widths and other parameters reported.
Proposal of an innovative benchmark for comparison of the performance of contactless digitizers
NASA Astrophysics Data System (ADS)
Iuliano, Luca; Minetola, Paolo; Salmi, Alessandro
2010-10-01
Thanks to the improving performances of 3D optical scanners, in terms of accuracy and repeatability, reverse engineering applications have extended from CAD model design or reconstruction to quality control. Today, contactless digitizing devices constitute a good alternative to coordinate measuring machines (CMMs) for the inspection of certain parts. The German guideline VDI/VDE 2634 is the only reference to evaluate whether 3D optical measuring systems comply with the declared or required performance specifications. Nevertheless it is difficult to compare the performance of different scanners referring to such a guideline. An adequate novel benchmark is proposed in this paper: focusing on the inspection of production tools (moulds), the innovative test piece was designed using common geometries and free-form surfaces. The reference part is intended to be employed for the evaluation of the performance of several contactless digitizing devices in computer-aided inspection, considering dimensional and geometrical tolerances as well as other quantitative and qualitative criteria.
Design and tolerance analysis of a transmission sphere by interferometer model
NASA Astrophysics Data System (ADS)
Peng, Wei-Jei; Ho, Cheng-Fong; Lin, Wen-Lung; Yu, Zong-Ru; Huang, Chien-Yao; Hsu, Wei-Yao
2015-09-01
The design of a 6-in, f/2.2 transmission sphere for Fizeau interferometry is presented in this paper. To predict the actual performance during design phase, we build an interferometer model combined with tolerance analysis in Zemax. Evaluating focus imaging is not enough for a double pass optical system. Thus, we study the interferometer model that includes system error, wavefronts reflected from reference surface and tested surface. Firstly, we generate a deformation map of the tested surface. Because of multiple configurations in Zemax, we can get the test wavefront and the reference wavefront reflected from the tested surface and the reference surface of transmission sphere respectively. According to the theory of interferometry, we subtract both wavefronts to acquire the phase of tested surface. Zernike polynomial is applied to transfer the map from phase to sag and to remove piston, tilt and power. The restored map is the same as original map; because of no system error exists. Secondly, perturbed tolerances including fabrication of lenses and assembly are considered. The system error occurs because the test and reference beam are no longer common path perfectly. The restored map is inaccurate while the system error is added. Although the system error can be subtracted by calibration, it should be still controlled within a small range to avoid calibration error. Generally the reference wavefront error including the system error and the irregularity of the reference surface of 6-in transmission sphere is measured within peak-to-valley (PV) 0.1 λ (λ=0.6328 um), which is not easy to approach. Consequently, it is necessary to predict the value of system error before manufacture. Finally, a prototype is developed and tested by a reference surface with PV 0.1 λ irregularity.
A Simple Spectrophotometer Using Common Materials and a Digital Camera
ERIC Educational Resources Information Center
Widiatmoko, Eko; Widayani; Budiman, Maman; Abdullah, Mikrajuddin; Khairurrijal
2011-01-01
A simple spectrophotometer was designed using cardboard, a DVD, a pocket digital camera, a tripod and a computer. The DVD was used as a diffraction grating and the camera as a light sensor. The spectrophotometer was calibrated using a reference light prior to use. The spectrophotometer was capable of measuring optical wavelengths with a…
ERIC Educational Resources Information Center
Oberhofer, Margret; Colpaert, Jozef
2015-01-01
TLC Pack stands for Teaching Languages to Caregivers and is a course designed to support migrants working or hoping to work in the caregiving sector. The TLC Pack resources range from A2 to B2 level of the Common European Framework of Reference for Languages (CEFR), and will be made available online in the six project languages: Dutch, English,…
Get That Job! A Project on the German Job Application Process
ERIC Educational Resources Information Center
Magedera-Hofhansl, Hanna
2016-01-01
With decreasing numbers of students studying German at Higher Education Institutions in the United Kingdom, there is an increasing demand for graduate Germanists. This project, designed for C1/C2 level students according to the Common European Framework of Reference for languages, prepares finalist students for a job market in which UK and German…
ERIC Educational Resources Information Center
Flaherty, Aishling; O'Dwyer, Anne; Mannix-McNamara, Patricia; Leahy, J. J.
2017-01-01
Throughout countries such as Ireland, the U.K., and Australia, graduate students who fulfill teaching roles in the undergraduate laboratory are often referred to as "laboratory demonstrators". The laboratory demonstrator (LD) model of graduate teaching is similar to the more commonly known graduate teaching assistant (GTA) model that is…
ERIC Educational Resources Information Center
Goldhaber, Dan; Gross, Betheny; DeBurgomaster, Scott
2008-01-01
This paper reviews state cross-institutional policies designed to better integrate state community colleges with traditional four-year colleges and university system schools, commonly referred to as "transfer and articulation policies," and examines how patterns of college attendance, transfer, and degree earning vary across states with different…
Starting a Day Care Center: The Day Care Center Handbook.
ERIC Educational Resources Information Center
Checkett, Donald
Designed to be of help to individuals and groups seeking to establish a day care center in the metropolitan St. Louis area, this manual calls attention to important and basic information which must be taken into account if planning is to produce tangible results. Following a brief section defining commonly used terms referring to organized…
The design of common aperture and multi-band optical system based on day light telescope
NASA Astrophysics Data System (ADS)
Chen, Jiao; Wang, Ling; Zhang, Bo; Teng, Guoqi; Wang, Meng
2017-02-01
As the development of electro-optical weapon system, the technique of common path and multi-sensor are used popular, and becoming a trend. According to the requirement of miniaturization and lightweight for electro-optical stabilized sighting system, a day light telescope/television viewing-aim system/ laser ranger has been designed in this thesis, which has common aperture. Thus integration scheme of multi-band and common aperture has been adopted. A day light telescope has been presented, which magnification is 8, field of view is 6°, and distance of exit pupil is more than 20mm. For 1/3" CCD, television viewing-aim system which has 156mm focal length, has been completed. In addition, laser ranging system has been designed, with 10km raging distance. This paper outlines its principle which used day light telescope as optical reference of correcting the optical axis. Besides, by means of shared objective, reserved image with inverting prism and coating beam-splitting film on the inclined plane of the cube prism, the system has been applied to electro-optical weapon system, with high-resolution of imaging and high-precision ranging.
Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa
2010-01-01
Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555
Delusions of reference: a new theoretical model.
Startup, Mike; Bucci, Sandra; Langdon, Robyn
2009-03-01
Although delusions of reference are one of the most common psychotic symptoms, they have been the focus of little research, possibly because they have been considered to be integral to persecutory delusions. Evidence has now emerged that there are two kinds of delusion of reference. One of these, referential delusions of communication, which involves beliefs that others are communicating in subtle, nonverbal ways, is the focus of this paper. We present a new model designed to account for the four crucial aspects of the phenomenology of these delusions: (1) that neutral stimuli are experienced as having personal significance; (2) that the neutral stimuli are experienced as communicating a message nonverbally; (3) that the content of the message concerns the self; (4) that the experience of a self-referent communication is believed rather than being dismissed as implausible. We used PsycINFO and Scopus, using the term "delusion* of reference", to search for publications with a bearing on our model. The amount of research we found that was designed to test aspects of this model is small but other published research appears to provide some support for its various steps. Much of this research was not explicitly intended to provide an account of delusions of reference but its relevance nevertheless seems clear. There is preliminary support for the plausibility of our model but much additional research is needed. We conclude by summarising what we consider to be the main desiderata.
Veal, Colin D.; Xu, Hang; Reekie, Katherine; Free, Robert; Hardwick, Robert J.; McVey, David; Brookes, Anthony J.; Hollox, Edward J.; Talbot, Christopher J.
2013-01-01
Motivation: Genomic copy number variation (CNV) can influence susceptibility to common diseases. High-throughput measurement of gene copy number on large numbers of samples is a challenging, yet critical, stage in confirming observations from sequencing or array Comparative Genome Hybridization (CGH). The paralogue ratio test (PRT) is a simple, cost-effective method of accurately determining copy number by quantifying the amplification ratio between a target and reference amplicon. PRT has been successfully applied to several studies analyzing common CNV. However, its use has not been widespread because of difficulties in assay design. Results: We present PRTPrimer (www.prtprimer.org) software for automated PRT assay design. In addition to stand-alone software, the web site includes a database of pre-designed assays for the human genome at an average spacing of 6 kb and a web interface for custom assay design. Other reference genomes can also be analyzed through local installation of the software. The usefulness of PRTPrimer was tested within known CNV, and showed reproducible quantification. This software and database provide assays that can rapidly genotype CNV, cost-effectively, on a large number of samples and will enable the widespread adoption of PRT. Availability: PRTPrimer is available in two forms: a Perl script (version 5.14 and higher) that can be run from the command line on Linux systems and as a service on the PRTPrimer web site (www.prtprimer.org). Contact: cjt14@le.ac.uk Supplementary Information: Supplementary data are available at Bioinformatics online. PMID:23742985
Kudo, Toru; Sasaki, Yohei; Terashima, Shin; Matsuda-Imai, Noriko; Takano, Tomoyuki; Saito, Misa; Kanno, Maasa; Ozaki, Soichi; Suwabe, Keita; Suzuki, Go; Watanabe, Masao; Matsuoka, Makoto; Takayama, Seiji; Yano, Kentaro
2016-10-13
In quantitative gene expression analysis, normalization using a reference gene as an internal control is frequently performed for appropriate interpretation of the results. Efforts have been devoted to exploring superior novel reference genes using microarray transcriptomic data and to evaluating commonly used reference genes by targeting analysis. However, because the number of specifically detectable genes is totally dependent on probe design in the microarray analysis, exploration using microarray data may miss some of the best choices for the reference genes. Recently emerging RNA sequencing (RNA-seq) provides an ideal resource for comprehensive exploration of reference genes since this method is capable of detecting all expressed genes, in principle including even unknown genes. We report the results of a comprehensive exploration of reference genes using public RNA-seq data from plants such as Arabidopsis thaliana (Arabidopsis), Glycine max (soybean), Solanum lycopersicum (tomato) and Oryza sativa (rice). To select reference genes suitable for the broadest experimental conditions possible, candidates were surveyed by the following four steps: (1) evaluation of the basal expression level of each gene in each experiment; (2) evaluation of the expression stability of each gene in each experiment; (3) evaluation of the expression stability of each gene across the experiments; and (4) selection of top-ranked genes, after ranking according to the number of experiments in which the gene was expressed stably. Employing this procedure, 13, 10, 12 and 21 top candidates for reference genes were proposed in Arabidopsis, soybean, tomato and rice, respectively. Microarray expression data confirmed that the expression of the proposed reference genes under broad experimental conditions was more stable than that of commonly used reference genes. These novel reference genes will be useful for analyzing gene expression profiles across experiments carried out under various experimental conditions.
Kassam, Aliya; Sharma, Nishan; Harvie, Margot; O’Beirne, Maeve; Topps, Maureen
2016-01-01
Abstract Objective To conduct a thematic analysis of the College of Family Physicians of Canada’s (CFPC’s) Red Book accreditation standards and the Triple C Competency-based Curriculum objectives with respect to patient safety principles. Design Thematic content analysis of the CFPC’s Red Book accreditation standards and the Triple C curriculum. Setting Canada. Main outcome measures Coding frequency of the patient safety principles (ie, patient engagement; respectful, transparent relationships; complex systems; a just and trusting culture; responsibility and accountability for actions; and continuous learning and improvement) found in the analyzed CFPC documents. Results Within the analyzed CFPC documents, the most commonly found patient safety principle was patient engagement (n = 51 coding references); the least commonly found patient safety principles were a just and trusting culture (n = 5 coding references) and complex systems (n = 5 coding references). Other patient safety principles that were uncommon included responsibility and accountability for actions (n = 7 coding references) and continuous learning and improvement (n = 12 coding references). Conclusion Explicit inclusion of patient safety content such as the use of patient safety principles is needed for residency training programs across Canada to ensure the full spectrum of care is addressed, from community-based care to acute hospital-based care. This will ensure a patient safety culture can be cultivated from residency and sustained into primary care practice. PMID:27965349
ERIC Educational Resources Information Center
Pierce, Joana; Duran, Pilar; Ubeda, Paloma
2011-01-01
Engineering institutions across Europe are currently involved in a major process of reform and restructuring as a part of the Bologna Process, which stresses the role of competencies and outcomes in curriculum design. In the field of languages, the Council of Europe has developed the CEFR (Common European Framework of References) for languages,…
Education Stimulus Funds: An Opportunity to Plan Ahead
ERIC Educational Resources Information Center
Shakrani, Sharif
2009-01-01
Designed to stimulate the economy and employment, the "American Recovery and Reinvestment Act of 2009" (ARRA), commonly referred to as the stimulus package or plan, is a crucial step in a massive effort to create and save 3 to 4 million jobs, jump-start the U.S. economy and begin the process of transforming the economy for the 21st…
The Effectiveness of Circular Equating as a Criterion for Evaluating Equating.
ERIC Educational Resources Information Center
Wang, Tianyou; Hanson, Bradley A.; Harris, Deborah J.
Equating a test form to itself through a chain of equatings, commonly referred to as circular equating, has been widely used as a criterion to evaluate the adequacy of equating. This paper uses both analytical methods and simulation methods to show that this criterion is in general invalid in serving this purpose. For the random groups design done…
MEMS Reliability Assurance Guidelines for Space Applications
NASA Technical Reports Server (NTRS)
Stark, Brian (Editor)
1999-01-01
This guide is a reference for understanding the various aspects of microelectromechanical systems, or MEMS, with an emphasis on device reliability. Material properties, failure mechanisms, processing techniques, device structures, and packaging techniques common to MEMS are addressed in detail. Design and qualification methodologies provide the reader with the means to develop suitable qualification plans for the insertion of MEMS into the space environment.
"Looking through the Eyes of the Learner": Implementation of Building Blocks for Student Engagement
ERIC Educational Resources Information Center
D'Annolfo, Suzanne Cordier; Schumann, Jeffrey A.
2012-01-01
The Building Blocks for Student Engagement (BBSE) protocol was designed to provide a consistent framework of common language and a visual point of reference shared among students, teachers and school leaders to keep a laser-like focus on the instructional core and student engagement. Grounded in brain-based learning and implemented in urban,…
Gregory Elmes; Thomas Millette; Charles B. Yuill
1991-01-01
GypsES, a decision-support and expert system for the management of Gypsy Moth addresses five related research problems in a modular, computer-based project. The modules are hazard rating, monitoring, prediction, treatment decision and treatment implementation. One common component is a geographic information system designed to function intelligently. We refer to this...
ERIC Educational Resources Information Center
Xie, Ying; Sharma, Priya
2013-01-01
Reflective learning refers to a learner's purposeful and conscious manipulation of ideas toward meaningful learning. Blogs have been used to support reflective thinking, but the commonly seen blog software usually does not provide overt mechanisms for students' high-level reflections. A new tool was designed to support the reflective…
1984-07-01
level crossing rate equations first developed by Rice are commonly employed, reference 4. If one assumes that the wave height variance spectrum is...wave photo was kindly furnished by Mr. Dillard Hammett of SEDCO, Inc. : "The photo was taken in November, 1982. The location was the Ekofisk Field
ERIC Educational Resources Information Center
Ellsbury, Susan H.; And Others
A two-part text, "Science Resources: A Self-Paced Instructional Workbook," was designed to provide science students at Mississippi State University with: (1) instruction on basic library usage and reference tools common to most scientific disciplines; (2) materials adapted to specific disciplines; and (3) services available to them from the…
Uptake of recommended common reference intervals for chemical pathology in Australia.
Jones, Graham Rd; Koetsier, Sabrina
2017-05-01
Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.
Evaluation of a 6-wire thermocouple psychrometer for determination of in-situ water potentials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loskot, C.L.; Rousseau, J.P.; Kurzmack, M.A.
1994-12-31
A 6-wire, Peltier-type thermocouple psychrometer was designed and evaluated by the U.S. Geological Survey for monitoring in-situ water potentials in dry-drilled boreholes in the unsaturated zone at Yucca Mountain, Nye County, Nevada. The psychrometer consists of a wet-bulb, chromel-constantan, sensing junction and a separate dry-bulb, copper-constantan, reference junction. Two additional reference junctions are formed where the chromel and constantan wires of the wet-bulb sensing junction are soldered to separate, paired, copper, lead wires. In contrast, in the standard 3-wire thermocouple psychrometer, both the wet bulb and dry bulb share a common wire. The new design has resulted in a psychrometermore » that has an expanded range and greater reliability, sensitivity, and accuracy compared to the standard model.« less
Common path in-line holography using enhanced joint object reference digital interferometers
Kelner, Roy; Katz, Barak; Rosen, Joseph
2014-01-01
Joint object reference digital interferometer (JORDI) is a recently developed system capable of recording holograms of various types [Opt. Lett. 38(22), 4719 (2013)24322115]. Presented here is a new enhanced system design that is based on the previous JORDI. While the previous JORDI has been based purely on diffractive optical elements, displayed on spatial light modulators, the present design incorporates an additional refractive objective lens, thus enabling hologram recording with improved resolution and increased system applicability. Experimental results demonstrate successful hologram recording for various types of objects, including transmissive, reflective, three-dimensional, phase and highly scattering objects. The resolution limit of the system is analyzed and experimentally validated. Finally, the suitability of JORDI for microscopic applications is verified as a microscope objective based configuration of the system is demonstrated. PMID:24663838
Selecting and Improving Quasi-Experimental Designs in Effectiveness and Implementation Research.
Handley, Margaret A; Lyles, Courtney R; McCulloch, Charles; Cattamanchi, Adithya
2018-04-01
Interventional researchers face many design challenges when assessing intervention implementation in real-world settings. Intervention implementation requires holding fast on internal validity needs while incorporating external validity considerations (such as uptake by diverse subpopulations, acceptability, cost, and sustainability). Quasi-experimental designs (QEDs) are increasingly employed to achieve a balance between internal and external validity. Although these designs are often referred to and summarized in terms of logistical benefits, there is still uncertainty about (a) selecting from among various QEDs and (b) developing strategies to strengthen the internal and external validity of QEDs. We focus here on commonly used QEDs (prepost designs with nonequivalent control groups, interrupted time series, and stepped-wedge designs) and discuss several variants that maximize internal and external validity at the design, execution and implementation, and analysis stages.
UniPrime2: a web service providing easier Universal Primer design.
Boutros, Robin; Stokes, Nicola; Bekaert, Michaël; Teeling, Emma C
2009-07-01
The UniPrime2 web server is a publicly available online resource which automatically designs large sets of universal primers when given a gene reference ID or Fasta sequence input by a user. UniPrime2 works by automatically retrieving and aligning homologous sequences from GenBank, identifying regions of conservation within the alignment, and generating suitable primers that can be used to amplify variable genomic regions. In essence, UniPrime2 is a suite of publicly available software packages (Blastn, T-Coffee, GramAlign, Primer3), which reduces the laborious process of primer design, by integrating these programs into a single software pipeline. Hence, UniPrime2 differs from previous primer design web services in that all steps are automated, linked, saved and phylogenetically delimited, only requiring a single user-defined gene reference ID or input sequence. We provide an overview of the web service and wet-laboratory validation of the primers generated. The system is freely accessible at: http://uniprime.batlab.eu. UniPrime2 is licenced under a Creative Commons Attribution Noncommercial-Share Alike 3.0 Licence.
Best practices for hybridization design in two-colour microarray analysis.
Knapen, Dries; Vergauwen, Lucia; Laukens, Kris; Blust, Ronny
2009-07-01
Two-colour microarrays are a popular platform of choice in gene expression studies. Because two different samples are hybridized on a single microarray, and several microarrays are usually needed in a given experiment, there are many possible ways to combine samples on different microarrays. The actual combination employed is commonly referred to as the 'hybridization design'. Different types of hybridization designs have been developed, all aimed at optimizing the experimental setup for the detection of differentially expressed genes while coping with technical noise. Here, we first provide an overview of the different classes of hybridization designs, discussing their advantages and limitations, and then we illustrate the current trends in the use of different hybridization design types in contemporary research.
Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani
2014-01-01
This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems. PMID:25013854
Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani
2014-01-01
This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.
Medical tourism services available to residents of the United States.
Alleman, Brandon W; Luger, Tana; Reisinger, Heather Schacht; Martin, Rene; Horowitz, Michael D; Cram, Peter
2011-05-01
There are growing reports of United States (US) residents traveling overseas for medical care, but empirical data about medical tourism are limited. To characterize the businesses and business practices of entities promoting medical tourism and the types and costs of procedures being offered. DESIGN, PARTICIPANTS, AND OUTCOMES: Between June and August 2008, we conducted a telephone survey of all businesses engaged in facilitating overseas medical travel for US residents. We collected information from each company including: the number of employees; number of patients referred overseas; medical records security processes; destinations to which patients were referred; treatments offered; treatment costs; and whether patient outcomes were collected. We identified 63 medical tourism companies and 45 completed our survey (71%). Companies had a mean of 9.8 employees and had referred an average of 285 patients overseas (a total of approximately 13,500 patients). 35 (79%) companies reported requiring accreditation of foreign providers, 22 (50%) collected patient outcome data, but only 17 (39%) described formal medical records security policies. The most common destinations were India (23 companies, 55%), Costa Rica (14, 33%), and Thailand (12, 29%). The most common types of care included orthopedics (32 companies, 73%), cardiac care (23, 52%), and cosmetic surgery (29, 66%). 20 companies (44%) offered treatments not approved for use in the US--most commonly stem cell therapy. Average costs for common procedures, CABG ($18,600) and knee arthroplasty ($10,800), were similar to previous reports. The number of Americans traveling overseas for medical care with assistance from medical tourism companies is relatively small. Attention to medical records security and patient outcomes is variable and cost-savings are dependent on US prices. That said, overseas medical care can be a reasonable alternative for price sensitive patients in need of relatively common, elective medical procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delcamp, E.; Lagarde, B.; Polack, F.
Though optimization softwares are commonly used in visible optical design, none seems to exist for soft X-ray optics. It is shown here that optimization techniques can be applied with some advantages to X-UV monochromator design. A merit function, suitable for minimizing the aberrations is proposed, and the general method of computation is described. Samples of the software inputs and outputs are presented, and compared to reference data. As an example of application to soft X-ray monochromator design, the optimization of the soft X-ray monochromator of the ESRF microscopy beamline is presented. Good agreement between the predicted resolution of a modifiedmore » PGM monochromator and experimental measurements is reported.« less
Barrier-free design: a review and critique of the occupational therapy perspective.
Cooper, B A; Cohen, U; Hasselkus, B R
1991-04-01
This review of the occupational therapy literature on barrier-free design identifies both a paucity of related occupational therapy research on the topic and a lack of a common conceptual base with which to guide the development and use of environmental assessments. Nonetheless, two fledgling themes can be extrapolated: the consistent reference to the concepts of accessibility, mobility, function, and safety and an increased awareness among occupational therapists regarding the accessibility standards developed by the American National Standards Institute (ANSI) (ANSI, 1971, 1980). A problem-solving model suggested by designers for the 1979 revision of ANSI standards that incorporates these conceptual themes is described and discussed.
Aligning ESP Courses with the "Common European Framework of Reference for Languages"
ERIC Educational Resources Information Center
Athanasiou, Androulla; Constantinou, Elis Kakoulli; Neophytou, Maro; Nicolaou, Anna; Papadima Sophocleous, Salomi; Yerou, Christina
2016-01-01
This article explains how the "Common European Framework of References for Languages" (CEFR; Council of Europe 2001, "Common European Framework of Reference for Languages: Learning, teaching, assessment." Cambridge: Cambridge University Press) has been applied in language courses at the Language Centre (LC) of the Cyprus…
Rapid iterative reanalysis for automated design
NASA Technical Reports Server (NTRS)
Bhatia, K. G.
1973-01-01
A method for iterative reanalysis in automated structural design is presented for a finite-element analysis using the direct stiffness approach. A basic feature of the method is that the generalized stiffness and inertia matrices are expressed as functions of structural design parameters, and these generalized matrices are expanded in Taylor series about the initial design. Only the linear terms are retained in the expansions. The method is approximate because it uses static condensation, modal reduction, and the linear Taylor series expansions. The exact linear representation of the expansions of the generalized matrices is also described and a basis for the present method is established. Results of applications of the present method to the recalculation of the natural frequencies of two simple platelike structural models are presented and compared with results obtained by using a commonly applied analysis procedure used as a reference. In general, the results are in good agreement. A comparison of the computer times required for the use of the present method and the reference method indicated that the present method required substantially less time for reanalysis. Although the results presented are for relatively small-order problems, the present method will become more efficient relative to the reference method as the problem size increases. An extension of the present method to static reanalysis is described, ana a basis for unifying the static and dynamic reanalysis procedures is presented.
Conditions that masquerade as chronic rhinosinusitis: a medical record review.
Pynnonen, Melissa A; Terrell, Jeffrey E
2006-07-01
To identify conditions that are commonly mistaken for chronic rhinosinusitis (CRS). The hypothesis was that many patients referred to a rhinology clinic with a presumptive diagnosis of CRS do not have CRS. Retrospective, observational design study of adult patients referred for evaluation of CRS-like symptoms. The expert opinion of the rhinologist was the diagnostic standard. Tertiary care rhinology clinic. A consecutive sample of 186 patients referred to the University of Michigan Health Systems' Department of Otolaryngology-Head and Neck Surgery between April 1998 and June 2000 for evaluation of CRS-like symptoms. For each patient, a history was obtained and a physical examination was performed, including nasal endoscopy and, when indicated, computed tomographic evaluation of the sinuses. Each patient's diagnosis at referral, CRS, was compared with the final diagnosis made by the rhinologist. The final diagnoses were collected and analyzed using descriptive statistics. Of 186 patients, 112 (60%) had CRS and 74 (40%) did not. The most common diagnoses among the patients who did not have CRS were allergic rhinitis (n = 37), laryngitis associated with reflux (n = 21), head or facial pain (n = 18), and nonallergic rhinitis (n = 23). Many patients had more than 1 diagnosis. Among a tertiary care population, common medical disorders, including rhinitis, laryngitis associated with reflux, and headache disorders, may simulate CRS. Heightened awareness of these conditions may improve diagnostic accuracy in patients with CRS-like symptoms.
Inherent overload protection for the series resonant converter
NASA Technical Reports Server (NTRS)
King, R. J.; Stuart, T. A.
1983-01-01
The overload characteristics of the full bridge series resonant power converter are considered. This includes analyses of the two most common control methods presently in use. The first of these uses a current zero crossing detector to synchronize the control signals and is referred to as the alpha controller. The second is driven by a voltage controlled oscillator and is referred to as the gamma controller. It is shown that the gamma controller has certain reliability advantages in that it can be designed with inherent short circuit protection. Experimental results are included for an 86 kHz converter using power metal-oxide-semiconductor field-effect transistors (MOSFETs).
Cankorur-Cetinkaya, Ayca; Dereli, Elif; Eraslan, Serpil; Karabekmez, Erkan; Dikicioglu, Duygu; Kirdar, Betul
2012-01-01
Background Understanding the dynamic mechanism behind the transcriptional organization of genes in response to varying environmental conditions requires time-dependent data. The dynamic transcriptional response obtained by real-time RT-qPCR experiments could only be correctly interpreted if suitable reference genes are used in the analysis. The lack of available studies on the identification of candidate reference genes in dynamic gene expression studies necessitates the identification and the verification of a suitable gene set for the analysis of transient gene expression response. Principal Findings In this study, a candidate reference gene set for RT-qPCR analysis of dynamic transcriptional changes in Saccharomyces cerevisiae was determined using 31 different publicly available time series transcriptome datasets. Ten of the twelve candidates (TPI1, FBA1, CCW12, CDC19, ADH1, PGK1, GCN4, PDC1, RPS26A and ARF1) we identified were not previously reported as potential reference genes. Our method also identified the commonly used reference genes ACT1 and TDH3. The most stable reference genes from this pool were determined as TPI1, FBA1, CDC19 and ACT1 in response to a perturbation in the amount of available glucose and as FBA1, TDH3, CCW12 and ACT1 in response to a perturbation in the amount of available ammonium. The use of these newly proposed gene sets outperformed the use of common reference genes in the determination of dynamic transcriptional response of the target genes, HAP4 and MEP2, in response to relaxation from glucose and ammonium limitations, respectively. Conclusions A candidate reference gene set to be used in dynamic real-time RT-qPCR expression profiling in yeast was proposed for the first time in the present study. Suitable pools of stable reference genes to be used under different experimental conditions could be selected from this candidate set in order to successfully determine the expression profiles for the genes of interest. PMID:22675547
TLOG: Training and Educating Operational Logistic Planners
2008-05-22
monograph recommends specific changes to the current curriculum. Additions in operational knowledge provide the students technical knowledge and a...common frame of reference in campaign planning. The changes result in students not only technically competent to design a concept of support, but...planning process. The implementation of these changes enhance TLog’s curriculum to meet the course’s stated goal; the graduates will be the
ERIC Educational Resources Information Center
Andrews, Benjamin James
2011-01-01
The equity properties can be used to assess the quality of an equating. The degree to which expected scores conditional on ability are similar between test forms is referred to as first-order equity. Second-order equity is the degree to which conditional standard errors of measurement are similar between test forms after equating. The purpose of…
ERIC Educational Resources Information Center
Bronte-Tinkew, Jacinta; Horowitz, Allison; Redd, Zakia; Moore, Kristin A.; Valladares, Sherylls
2007-01-01
This glossary of common research and evaluation terms can serve as a quick reference guide for out-of school time practitioners as they face the challenges posed in this new era of program accountability. Subsequent briefs will provide more detailed information on particular types of research and evaluation designs. A list of additional resources…
Rep. Akin, W. Todd [R-MO-2
2009-02-26
Senate - 04/23/2009 Committee on Homeland Security and Governmental Affairs referred to Subcommittee on Federal Financial Management, Government Information, Federal Services, and International Security. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:
Design and Analysis of Architectures for Structural Health Monitoring Systems
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi; Sixto, S. L. (Technical Monitor)
2002-01-01
During the two-year project period, we have worked on several aspects of Health Usage and Monitoring Systems for structural health monitoring. In particular, we have made contributions in the following areas. 1. Reference HUMS architecture: We developed a high-level architecture for health monitoring and usage systems (HUMS). The proposed reference architecture is shown. It is compatible with the Generic Open Architecture (GOA) proposed as a standard for avionics systems. 2. HUMS kernel: One of the critical layers of HUMS reference architecture is the HUMS kernel. We developed a detailed design of a kernel to implement the high level architecture.3. Prototype implementation of HUMS kernel: We have implemented a preliminary version of the HUMS kernel on a Unix platform.We have implemented both a centralized system version and a distributed version. 4. SCRAMNet and HUMS: SCRAMNet (Shared Common Random Access Memory Network) is a system that is found to be suitable to implement HUMS. For this reason, we have conducted a simulation study to determine its stability in handling the input data rates in HUMS. 5. Architectural specification.
Construction of the Dependence Matrix Based on the TRIZ Contradiction Matrix in OOD
NASA Astrophysics Data System (ADS)
Ma, Jianhong; Zhang, Quan; Wang, Yanling; Luo, Tao
In the Object-Oriented software design (OOD), design of the class and object, definition of the classes’ interface and inheritance levels and determination of dependent relations have a serious impact on the reusability and flexibility of the system. According to the concrete problems of design, how to select the right solution from the hundreds of the design schemas which has become the focus of attention of designers. After analyzing lots of software design schemas in practice and Object-Oriented design patterns, this paper constructs the dependence matrix of Object-Oriented software design filed, referring to contradiction matrix of TRIZ (Theory of Inventive Problem Solving) proposed by the former Soviet Union innovation master Altshuller. As the practice indicates, it provides a intuitive, common and standardized method for designers to choose the right design schema. Make research and communication more effectively, and also improve the software development efficiency and software quality.
High pressure common rail injection system modeling and control.
Wang, H P; Zheng, D; Tian, Y
2016-07-01
In this paper modeling and common-rail pressure control of high pressure common rail injection system (HPCRIS) is presented. The proposed mathematical model of high pressure common rail injection system which contains three sub-systems: high pressure pump sub-model, common rail sub-model and injector sub-model is a relative complicated nonlinear system. The mathematical model is validated by the software Matlab and a virtual detailed simulation environment. For the considered HPCRIS, an effective model free controller which is called Extended State Observer - based intelligent Proportional Integral (ESO-based iPI) controller is designed. And this proposed method is composed mainly of the referred ESO observer, and a time delay estimation based iPI controller. Finally, to demonstrate the performances of the proposed controller, the proposed ESO-based iPI controller is compared with a conventional PID controller and ADRC. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
NASA CEV Reference Entry GN&C System and Analysis
NASA Technical Reports Server (NTRS)
Munday, S.; Madsen, C.; Broome, J.; Gay, R.; Tigges, M.; Strahan, A.
2007-01-01
As part of its overall objectives, the Orion spacecraft will be required to perform entry and Earth landing functions for Low Earth Orbit (LEO) and Lunar missions. Both of these entry scenarios will begin with separation of the Service Module (SM), making them unique from other Orion mission phases in that only the Command Module (CM) portion of the Crew Exploration Vehicle (CEV) will be involved, requiring a CM specific Guidance, Navigation and Control (GN&C) system. Also common to these mission scenarios will be the need for GN&C to safely return crew (or cargo) to earth within the dynamic thermal and structural constraints of entry and within acceptable accelerations on the crew, utilizing the limited aerodynamic performance of the CM capsule. The lunar return mission could additionally require an initial atmospheric entry designed to support a precision skip and second entry, all to maximize downrange performance and ensure landing in the United States. This paper describes the Entry GN&C reference design, developed by the NASA-led team, that supports these entry scenarios and that was used to validate the Orion System requirements. Description of the reference design will include an overview of the GN&C functions, avionics, and effectors and will relate these to the specific design drivers of the entry scenarios, as well as the desire for commonality in vehicle systems to support the different missions. The discussion will also include the requirement for an Emergency Entry capability beyond that of the nominal performance of the multi-string GNC system, intended to return the crew to the earth in a survivable but unguided manner. Finally, various analyses will be discussed, including those completed to support validation efforts of the current CEV requirements, along with those on-going and planned with the intention to further refine the requirements and to support design development work in conjunction with the prime contractor. Some of these ongoing analyses will include work to size effectors (jets) and fuel budgets, to refine skip entry concepts, to characterize navigation performance and uncertainties, to provide for SM disposal offshore and to identify requirements to support target site selection.
Hartling, Lisa; Bond, Kenneth; Santaguida, P Lina; Viswanathan, Meera; Dryden, Donna M
2011-08-01
To develop and test a study design classification tool. We contacted relevant organizations and individuals to identify tools used to classify study designs and ranked these using predefined criteria. The highest ranked tool was a design algorithm developed, but no longer advocated, by the Cochrane Non-Randomized Studies Methods Group; this was modified to include additional study designs and decision points. We developed a reference classification for 30 studies; 6 testers applied the tool to these studies. Interrater reliability (Fleiss' κ) and accuracy against the reference classification were assessed. The tool was further revised and retested. Initial reliability was fair among the testers (κ=0.26) and the reference standard raters κ=0.33). Testing after revisions showed improved reliability (κ=0.45, moderate agreement) with improved, but still low, accuracy. The most common disagreements were whether the study design was experimental (5 of 15 studies), and whether there was a comparison of any kind (4 of 15 studies). Agreement was higher among testers who had completed graduate level training versus those who had not. The moderate reliability and low accuracy may be because of lack of clarity and comprehensiveness of the tool, inadequate reporting of the studies, and variability in tester characteristics. The results may not be generalizable to all published studies, as the test studies were selected because they had posed challenges for previous reviewers with respect to their design classification. Application of such a tool should be accompanied by training, pilot testing, and context-specific decision rules. Copyright © 2011 Elsevier Inc. All rights reserved.
Tsai, Pei-Chien; Breen, Matthew
2012-09-01
To identify suitable reference genes for normalization of real-time quantitative PCR (RT-qPCR) assay data for common tumors of dogs. Malignant lymph node (n = 8), appendicular osteosarcoma (9), and histiocytic sarcoma (12) samples and control samples of various nonneoplastic canine tissues. Array-based comparative genomic hybridization (aCGH) data were used to guide selection of 9 candidate reference genes. Expression stability of candidate reference genes and 4 commonly used reference genes was determined for tumor samples with RT-qPCR assays and 3 software programs. LOC611555 was the candidate reference gene with the highest expression stability among the 3 tumor types. Of the commonly used reference genes, expression stability of HPRT was high in histiocytic sarcoma samples, and expression stability of Ubi and RPL32 was high in osteosarcoma samples. Some of the candidate reference genes had higher expression stability than did the commonly used reference genes. Data for constitutively expressed genes with high expression stability are required for normalization of RT-qPCR assay results. Without such data, accurate quantification of gene expression in tumor tissue samples is difficult. Results of the present study indicated LOC611555 may be a useful RT-qPCR assay reference gene for multiple tissue types. Some commonly used reference genes may be suitable for normalization of gene expression data for tumors of dogs, such as lymphomas, osteosarcomas, or histiocytic sarcomas.
Methods to estimate irrigated reference crop evapotranspiration - a review.
Kumar, R; Jat, M K; Shankar, V
2012-01-01
Efficient water management of crops requires accurate irrigation scheduling which, in turn, requires the accurate measurement of crop water requirement. Irrigation is applied to replenish depleted moisture for optimum plant growth. Reference evapotranspiration plays an important role for the determination of water requirements for crops and irrigation scheduling. Various models/approaches varying from empirical to physically base distributed are available for the estimation of reference evapotranspiration. Mathematical models are useful tools to estimate the evapotranspiration and water requirement of crops, which is essential information required to design or choose best water management practices. In this paper the most commonly used models/approaches, which are suitable for the estimation of daily water requirement for agricultural crops grown in different agro-climatic regions, are reviewed. Further, an effort has been made to compare the accuracy of various widely used methods under different climatic conditions.
ERIC Educational Resources Information Center
Markowitz, Joy; Carlson, Elaine; Frey, William; Riley, Jarnee; Shimshak, Amy; Heinzen, Harriotte; Strohl, Jeff; Klein, Sheri; Hyunshik, Lee
2006-01-01
The Pre-Elementary Education Longitudinal Study, commonly referred to as the PEELS study, is funded by the U.S. Department of Education's National Center for Special Education Research (NCSER). It will follow a nationally representative sample of children with disabilities ages 3-5 for a period of six years. This study is designed to describe the…
Measurement of myocardial native T1 in cardiovascular diseases and norm in 1291 subjects.
Liu, Joanna M; Liu, Alexander; Leal, Joana; McMillan, Fiona; Francis, Jane; Greiser, Andreas; Rider, Oliver J; Myerson, Saul; Neubauer, Stefan; Ferreira, Vanessa M; Piechnik, Stefan K
2017-09-28
Native T1-mapping provides quantitative myocardial tissue characterization for cardiovascular diseases (CVD), without the need for gadolinium. However, its translation into clinical practice is hindered by differences between techniques and the lack of established reference values. We provide typical myocardial T1-ranges for 18 commonly encountered CVDs using a single T1-mapping technique - Shortened Look-Locker Inversion Recovery (ShMOLLI), also used in the large UK Biobank and Hypertrophic Cardiomyopathy Registry study. We analyzed 1291 subjects who underwent CMR (1.5-Tesla, MAGNETOM-Avanto, Siemens Healthcare, Erlangen, Germany) between 2009 and 2016, who had a single CVD diagnosis, with mid-ventricular T1-map assessment. A region of interest (ROI) was placed on native T1-maps in the "most-affected myocardium", characterized by the presence of late gadolinium enhancement (LGE), or regional wall motion abnormalities (RWMA) on cines. Another ROI was placed in the "reference myocardium" as far as possible from LGE/RWMA, and in the septum if no focal abnormality was present. To further define normality, we included native T1 of healthy subjects from an existing dataset after sub-endocardial pixel-erosions. Native T1 of patients with normal CMR (938 ± 21 ms) was similar compared to healthy subjects (941 ± 23 ms). Across all patient groups (57 ± 19 yrs., 65% males), focally affected myocardium had significantly different T1 value compared to reference myocardium (all p < 0.001). In the affected myocardium, cardiac amyloidosis (1119 ± 61 ms) had the highest native T1 compared to normal and all other CVDs, while iron-overload (795 ± 58 ms) and Anderson-Fabry disease (863 ± 23 ms) had the lowest native reference T1 (all p < 0.001). Future studies designed to detect the large T1 differences between affected and reference myocardium are estimated to require small sample-sizes (n < 50). However, studies designed to detect the small T1 differences between reference myocardium in CVDs and healthy controls can require several thousand of subjects. We provide typical T1-ranges for common clinical cardiac conditions in the largest cohort to-date, using ShMOLLI T1-mapping at 1.5 T. Sample-size calculations from this study may be useful for the design of future studies and trials that use T1-mapping as an endpoint.
Orbiter processing facility service platform failure and redesign
NASA Technical Reports Server (NTRS)
Harris, Jesse L.
1988-01-01
In a high bay of the Orbiter Processing Facility (OPF) at the Kennedy Space Center, technicians were preparing the space shuttle orbiter Discovery for rollout to the Vehicle Assembly Building (VAB). A service platform, commonly referred to as an OPF Bucket, was being retracted when it suddenly fell, striking a technician and impacting Discovery's payload bay door. A critical component in the OPF Bucket hoist system had failed, allowing the platform to fall. The incident was thoroughly investigated by both NASA and Lockheed, revealing many design deficiencies within the system. The deficiencies and the design changes made to correct them are reviewed.
Common computational properties found in natural sensory systems
NASA Astrophysics Data System (ADS)
Brooks, Geoffrey
2009-05-01
Throughout the animal kingdom there are many existing sensory systems with capabilities desired by the human designers of new sensory and computational systems. There are a few basic design principles constantly observed among these natural mechano-, chemo-, and photo-sensory systems, principles that have been proven by the test of time. Such principles include non-uniform sampling and processing, topological computing, contrast enhancement by localized signal inhibition, graded localized signal processing, spiked signal transmission, and coarse coding, which is the computational transformation of raw data using broadly overlapping filters. These principles are outlined here with references to natural biological sensory systems as well as successful biomimetic sensory systems exploiting these natural design concepts.
Hoss, Aila; Menon, Akshara; Corso, Liza
2016-01-01
Context Public health enabling authorities establish the legal foundation for financing, organizing, and delivering public health services. State laws vary in terms of the content, depth, and breadth of these fundamental public health activities. Given this variance, the Institute of Medicine has identified state public health laws as an area that requires further examination. To respond to this call for further examination, the Centers for Disease Control and Prevention’s Public Health Law Program conducted a fundamental activities legal assessment on state public health laws. Objective The goal of the legal assessment was to examine state laws referencing frameworks representing public health department fundamental activities (ie, core and essential services) in an effort to identify, catalog, and describe enabling authorities of state governmental public health systems. Design In 2013, Public Health Law Program staff compiled a list of state statutes and regulations referencing different commonly-recognized public health frameworks of fundamental activities. The legal assessment included state fundamental activities laws available on WestlawNext as of July 2013. The results related to the 10 essential public health services and the 3 core public health functions were confirmed and updated in June 2016. Results Eighteen states reference commonly-recognized frameworks of fundamental activities in their laws. Thirteen states have listed the 10 essential public health services in their laws. Eight of these states have also referenced the 3 core public health functions in their laws. Five states reference only the core public health functions. Conclusions Several states reference fundamental activities in their state laws, particularly through use of the essential services framework. Further work is needed to capture the public health laws and practices of states that may be performing fundamental activities but without reference to a common framework. PMID:27682724
A Survey of Applications and Research in Integrated Design Systems Technology
NASA Technical Reports Server (NTRS)
1998-01-01
The initial part of the study was begun with a combination of literature searches, World Wide Web searches, and contacts with individuals and companies who were known to members of our team to have an interest in topics that seemed to be related to our study. There is a long list of such topics, such as concurrent engineering, design for manufacture, life-cycle engineering, systems engineering, systems integration, systems design, design systems, integrated product and process approaches, enterprise integration, integrated product realization, and similar terms. These all capture, at least in part, the flavor of what we describe here as integrated design systems. An inhibiting factor in this inquiry was the absence of agreed terminology for the study of integrated design systems. It is common for the term to be applied to what are essentially augmented Computer-Aided Design (CAD) systems, which are integrated only to the extent that agreements have been reached to attach proprietary extensions to proprietary CAD programs. It is also common for some to use the term integrated design systems to mean a system that applies only, or mainly, to the design phase of a product life cycle. It is likewise common for many of the terms listed earlier to be used as synonyms for integrated design systems. We tried to avoid this ambiguity by adopting the definition of integrated design systems that is implied in the introductory notes that we provided to our contacts, cited earlier. We thus arrived at this definition: Integrated Design Systems refers to the integration of the different tools and processes that comprise the engineering, of complex systems. It takes a broad view of the engineering of systems, to include consideration of the entire product realization process and the product life cycle. An important aspect of integrated design systems is the extent to which they integrate existing, "islands of automation" into a comprehensive design and product realization environment. As the study progressed, we relied increasingly upon a networking approach to lead us to new information. The departure point for such searches often was a government-sponsored project or a company initiative. The advantage of this approach was that short conversations with knowledgeable persons would usually cut through confusion over differences of terminology, thereby somewhat reducing the search space of the study. Even so, it was not until late in our eight-month inquiry that we began to see signs of convergence of the search, in the sense that a number of the latest inquiries began to turn up references to earlier contacts. As suggested above, this convergence often occurred with respect to particular government or company projects.
Adiabatic diesel engine component development: Reference engine for on-highway applications
NASA Technical Reports Server (NTRS)
Hakim, Nabil S.
1986-01-01
The main objectives were to select an advanced low heat rejection diesel reference engine (ADRE) and to carry out systems analysis and design. The ADRE concept selection consisted of: (1) rated point performance optimization; (2) study of various exhaust energy recovery scenarios; (3) components, systems and engine configuration studies; and (4) life cycle cost estimates of the ADRE economic worth. The resulting ADRE design proposed a reciprocator with many advanced features for the 1995 technology demonstration time frame. These included ceramic air gap insulated hot section structural components, high temperature tribology treatments, nonmechanical (camless) valve actuation systems, and elimination of the cylinder head gasket. ADRE system analysis and design resulted in more definition of the engine systems. These systems include: (1) electro-hydraulic valve actuation, (2) electronic common rail injection system; (3) engine electronic control; (4) power transfer for accessory drives and exhaust energy recovery systems; and (5) truck installation. Tribology and performance assessments were also carried out. Finite element and probability of survival analyses were undertaken for the ceramic low heat rejection component.
Use of human engineering standards in design
NASA Technical Reports Server (NTRS)
Rogers, J. G.; Armstrong, R.
1977-01-01
Results are presented for a research study intended to assess the impact of present human engineering standards on product design. The approach consisted of three basic steps: a comparison of two display panels to determine if, in fact, products designed to the same standards are truly standardized; a review of two existing standards to determine how well their information can be used to solve design problems; and a survey of human factors specialists to assess their opinions about standards. It is shown that standards have less than the desired influence on product design. This is evidenced by a lack of standardization between hardware designed under common standards, by deficiencies within the standards that detract from their usefulness and encourage users to ignore them, and by the respondents of the survey who consider standards less valuable than other reference sources for design implementation. Recommendations aimed at enhancing the use of standards are set forth.
ERIC Educational Resources Information Center
Tull, Ashley; Freeman, Jerrid P.
2011-01-01
Examined in this study were the identified frames of reference and locus of control used by 478 student affairs administrators. Administrator responses were examined to identify frames of reference most commonly used and their preference order. Locus of control most commonly used and the relationship between frames of reference and locus of…
Mars Pathfinder Project: Planetary Constants and Models
NASA Technical Reports Server (NTRS)
Vaughan, Robin
1995-01-01
This document provides a common set of astrodynamic constants and planetary models for use by the Mars Pathfinder Project. It attempts to collect in a single reference all the quantities and models in use across the project during development and for mission operations. These models are central to the navigation and mission design functions, but they are also used in other aspects of the project such as science observation planning and data reduction.
Design and Optimization of Multi-Pixel Transition-Edge Sensors for X-Ray Astronomy Applications
NASA Technical Reports Server (NTRS)
Smith, Stephen J.; Adams, Joseph S.; Bandler, Simon R.; Chervenak, James A.; Datesman, Aaron Michael; Eckart, Megan E.; Ewin, Audrey J.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.;
2017-01-01
Multi-pixel transition-edge sensors (TESs), commonly referred to as 'hydras', are a type of position sensitive micro-calorimeter that enables very large format arrays to be designed without commensurate increase in the number of readout channels and associated wiring. In the hydra design, a single TES is coupled to discrete absorbers via varied thermal links. The links act as low pass thermal filters that are tuned to give a different characteristic pulse shape for x-ray photons absorbed in each of the hydra sub pixels. In this contribution we report on the experimental results from hydras consisting of up to 20 pixels per TES. We discuss the design trade-offs between energy resolution, position discrimination and number of pixels and investigate future design optimizations specifically targeted at meeting the readout technology considered for Lynx.
Adaptive control in the presence of unmodeled dynamics. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Rohrs, C. E.
1982-01-01
Stability and robustness properties of a wide class of adaptive control algorithms in the presence of unmodeled dynamics and output disturbances were investigated. The class of adaptive algorithms considered are those commonly referred to as model reference adaptive control algorithms, self-tuning controllers, and dead beat adaptive controllers, developed for both continuous-time systems and discrete-time systems. A unified analytical approach was developed to examine the class of existing adaptive algorithms. It was discovered that all existing algorithms contain an infinite gain operator in the dynamic system that defines command reference errors and parameter errors; it is argued that such an infinite gain operator appears to be generic to all adaptive algorithms, whether they exhibit explicit or implicit parameter identification. It is concluded that none of the adaptive algorithms considered can be used with confidence in a practical control system design, because instability will set in with a high probability.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Construction of a pulse-coupled dipole network capable of fear-like and relief-like responses
NASA Astrophysics Data System (ADS)
Lungsi Sharma, B.
2016-07-01
The challenge for neuroscience as an interdisciplinary programme is the integration of ideas among the disciplines to achieve a common goal. This paper deals with the problem of deriving a pulse-coupled neural network that is capable of demonstrating behavioural responses (fear-like and relief-like). Current pulse-coupled neural networks are designed mostly for engineering applications, particularly image processing. The discovered neural network was constructed using the method of minimal anatomies approach. The behavioural response of a level-coded activity-based model was used as a reference. Although the spiking-based model and the activity-based model are of different scales, the use of model-reference principle means that the characteristics that is referenced is its functional properties. It is demonstrated that this strategy of dissection and systematic construction is effective in the functional design of pulse-coupled neural network system with nonlinear signalling. The differential equations for the elastic weights in the reference model are replicated in the pulse-coupled network geometrically. The network reflects a possible solution to the problem of punishment and avoidance. The network developed in this work is a new network topology for pulse-coupled neural networks. Therefore, the model-reference principle is a powerful tool in connecting neuroscience disciplines. The continuity of concepts and phenomena is further maintained by systematic construction using methods like the method of minimal anatomies.
Buehler, James W; Bernet, Patrick M; Ogden, Lydia L
2012-01-01
Funding formulas are commonly used by federal agencies to allocate program funds to states. As one approach to evaluating differences in allocations resulting from alternative formula calculations, we propose the use of a measure derived from the Gini index to summarize differences in allocations relative to 2 referent allocations: one based on equal per-capita funding across states and another based on equal funding per person living in poverty, which we define as the "proportionality of allocation" (PA). These referents reflect underlying values that often shape formula-based allocations for public health programs. The size of state populations serves as a general proxy for the amount of funding needed to support programs across states. While the size of state populations living in poverty is correlated with overall population size, allocations based on states' shares of the national population living in poverty reflect variations in funding need shaped by the association between poverty and multiple adverse health outcomes. The PA measure is a summary of the degree of dispersion in state-specific allocations relative to the referent allocations and provides a quick assessment of the impact of selecting alternative funding formula designs. We illustrate the PA values by adjusting a sample allocation, using various measures of the salary costs and in-state wealth, which might modulate states' needs for federal funding.
Astigmatism corrected common path probe for optical coherence tomography.
Singh, Kanwarpal; Yamada, Daisuke; Tearney, Guillermo
2017-03-01
Optical coherence tomography (OCT) catheters for intraluminal imaging are subject to various artifacts due to reference-sample arm dispersion imbalances and sample arm beam astigmatism. The goal of this work was to develop a probe that minimizes such artifacts. Our probe was fabricated using a single mode fiber at the tip of which a glass spacer and graded index objective lens were spliced to achieve the desired focal distance. The signal was reflected using a curved reflector to correct for astigmatism caused by the thin, protective, transparent sheath that surrounds the optics. The probe design was optimized using Zemax, a commercially available optical design software. Common path interferometric operation was achieved using Fresnel reflection from the tip of the focusing graded index objective lens. The performance of the probe was tested using a custom designed spectrometer-based OCT system. The probe achieved an axial resolution of 15.6 μm in air, a lateral resolution 33 μm, and a sensitivity of 103 dB. A scattering tissue phantom was imaged to test the performance of the probe for astigmatism correction. Images of the phantom confirmed that this common-path, astigmatism-corrected OCT imaging probe had minimal artifacts in the axial, and lateral dimensions. In this work, we developed an astigmatism-corrected, common path probe that minimizes artifacts associated with standard OCT probes. This design may be useful for OCT applications that require high axial and lateral resolutions. Lasers Surg. Med. 49:312-318, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Cosmanescu, Alin; Miller, Benjamin; Magno, Terence; Ahmed, Assad; Kremenic, Ian
2006-01-01
A portable, multi-purpose Bio-instrumentation Amplifier and Data AcQuisition device (BADAQ) capable of measuring and transmitting EMG and EKG signals wirelessly via Bluetooth is designed and implemented. Common topologies for instrumentation amplifiers and filters are used and realized with commercially available, low-voltage, high precision operational amplifiers. An 8-bit PIC microcontroller performs 10-bit analog-to-digital conversion of the amplified and filtered signals and controls a Bluetooth transceiver capable of wirelessly transmitting the data to any Bluetooth enabled device. Electrical isolation between patient/subject, circuitry, and ancillary equipment is achieved by optocoupling components. The design focuses on simplicity, portability, and affordability.
1984-12-01
input/output relationship. These are obtained from the design specifications (10:68i-684). Note that the first digit of the subscript of bkj refers...to the output and the second digit to the input. Thus, bkj is.a function of the response requirements on the output, Yk’ due to the input, r.. 169 . A...NXPMAX pNYPMAX, IPLOT) C C C* LIBARY OF PLOT SUBR(OUTINES PSNTCT NLIEPRINTER ONLY~ C* C C C SUP’ LPLOTS C C C DIMENSION IXY(101,71)918UF(100) COMMON /HOPY
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
2012-01-01
This paper presents an overview of the third major revision to an algorithm specifically designed to support NASA's Airborne Precision Spacing concept. This algorithm is referred to as the Airborne Spacing for Terminal Arrival Routes version 11 (ASTAR11). This airborne self-spacing concept is trajectory-based, allowing for spacing operations prior to the aircraft being on a common path. Because this algorithm is trajectory-based, it also has the inherent ability to support required time-of-arrival (RTA) operations. This algorithm was also designed specifically to support a standalone, non-integrated implementation in the spacing aircraft.
NASA Astrophysics Data System (ADS)
Hess, M.; Robson, S.
2012-07-01
3D colour image data generated for the recording of small museum objects and archaeological finds are highly variable in quality and fitness for purpose. Whilst current technology is capable of extremely high quality outputs, there are currently no common standards or applicable guidelines in either the museum or engineering domain suited to scientific evaluation, understanding and tendering for 3D colour digital data. This paper firstly explains the rationale towards and requirements for 3D digital documentation in museums. Secondly it describes the design process, development and use of a new portable test object suited to sensor evaluation and the provision of user acceptance metrics. The test object is specifically designed for museums and heritage institutions and includes known surface and geometric properties which support quantitative and comparative imaging on different systems. The development for a supporting protocol will allow object reference data to be included in the data processing workflow with specific reference to conservation and curation.
GABBARD, GLEN O.
1995-01-01
When psychotherapists accused of sexual misconduct are referred for personal psychotherapy, formidable challenges are presented to the clinician designated as the psychotherapist. The author outlines common transference-countertransference themes and discusses them in terms of their psychodynamic underpinnings and optimal management. These themes include the therapist as a law enforcement agent, the therapist as a corruptible object, the therapist as a love object, the therapist as a rescuer and absolver, the therapist as an authoritarian parent, and the therapist as a voyeur. A common thread in all of these transference-counter-transference paradigms involves the discomfort experienced by the treating psychotherapists when they recognize aspects of themselves in the accused professional. PMID:22700209
A 311-GHz Fundamental Oscillator Using InP HBT Technology
NASA Technical Reports Server (NTRS)
Gaier, Todd; Fung, King Man; Samoska, Lorene; Radisic, Vesna; Sawdai, Donald; Scott, Dennis; Deal, W.R.
2010-01-01
This oscillator uses a single-emitter 0.3- m InP heterojunction bipolar transistor (HBT) device with maximum frequency of oscillation (fmax) greater than 500 GHz. Due to high conductor and substrate losses at submillimeterwave frequencies, a primary challenge is to efficiently use the intrinsic device gain. This was done by using a suitable transmission-line media and circuit topology. The passive components of the oscillator are realized in a twometal process with benzocyclobutene (BCB) used as the primary transmission line dielectric. The circuit was designed using microstrip transmission lines. The oscillator is implemented in a common-base topology due to its inherent instability, and the design includes an on-chip resonator, outputmatching circuitry, and an injection-locking port, the port being used to demonstrate the injection-locking prin ciple. A free-running frequency of 311.6 GHz has been measured by down-converting the signal. Ad di tionally, injection locking has been successfully demonstrated with up to 17.8 dB of injection-locking gain. The injection-locking reference signal is generated using a 2 20 GHz frequency synthesizer, followed by a doubler, active tripler, a W-band amplifier, and then a passive tripler. Therefore, the source frequency is multiplied 18 times to obtain a signal above 300 GHz that can be used to injection lock the oscillator. Measurement shows that injection locking has improved the phase noise of the oscillator and can be also used for synchronizing a series of oscillators. A signal conductor is implemented near the BCP -InP interface and the topside of the BCB layer is fully metallized as a signal ground. Because the fields are primarily constrained in the lower permittivity BCB region, this type of transmission line is referred to as an inverted microstrip. In addition, both common-emitter and commonbase circuits were investigated to determine optimum topology for oscillator design. The common -base topology required smaller amount of feedback than the common-emitter design, therefore preserving device gain, and was chosen for the oscillator design. The submillimeter-wave region offers several advantages for sensors and communication systems, such as high resolution and all-weather imaging due to the short-wavelength, and improved communication speeds by access to greater frequency bandwidth. This oscillator circuit is a prototype of the first HBT oscillator operating above 300 GHz. Additional development is necessary to increase the output power of the circuit for radar and imaging applications.
New self-magnetically insulated connection of multilevel accelerators to a common load
VanDevender, J. Pace; Langston, William L.; Pasik, Michael F.; ...
2015-03-04
A new way to connect pulsed-power modules to a common load is presented. Unlike previous connectors, the clam shell magnetically insulated transmission line (CSMITL) has magnetic nulls only at large radius where the cathode electric field is kept below the threshold for emission, has only a simply connected magnetic topology to avoid plasma motion along magnetic field lines into highly stressed gaps, and has electron injectors that ensure efficient electron flow even in the limiting case of self-limited MITLs. Multilevel magnetically insulated transmission lines with a posthole convolute are the standard solution but associated losses limit the performance of state-of-the-artmore » accelerators. Mitigating these losses is critical for the next generation of pulsed-power accelerators. A CSMITL has been successfully implemented on the Saturn accelerator. A reference design for the Z accelerator is derived and presented. The design conservatively meets the design requirements and shows excellent transport efficiency in three simulations of increasing complexity: circuit simulations, electromagnetic fields only with Emphasis, fields plus electron and ion emission with Quicksilver.« less
A Software Defined Radio Based Airplane Communication Navigation Simulation System
NASA Astrophysics Data System (ADS)
He, L.; Zhong, H. T.; Song, D.
2018-01-01
Radio communication and navigation system plays important role in ensuring the safety of civil airplane in flight. Function and performance should be tested before these systems are installed on-board. Conventionally, a set of transmitter and receiver are needed for each system, thus all the equipment occupy a lot of space and are high cost. In this paper, software defined radio technology is applied to design a common hardware communication and navigation ground simulation system, which can host multiple airplane systems with different operating frequency, such as HF, VHF, VOR, ILS, ADF, etc. We use a broadband analog frontend hardware platform, universal software radio peripheral (USRP), to transmit/receive signal of different frequency band. Software is compiled by LabVIEW on computer, which interfaces with USRP through Ethernet, and is responsible for communication and navigation signal processing and system control. An integrated testing system is established to perform functional test and performance verification of the simulation signal, which demonstrate the feasibility of our design. The system is a low-cost and common hardware platform for multiple airplane systems, which provide helpful reference for integrated avionics design.
76 FR 32067 - Common Crop Insurance Regulations; Extra Long Staple Cotton Crop Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-03
... 0563-AC27 Common Crop Insurance Regulations; Extra Long Staple Cotton Crop Provisions AGENCY: Federal... (FCIC) finalizes amendments made to the Common Crop Insurance Regulations, Extra Long Staple Cotton Crop Insurance Provisions to remove all references to the Daily Spot Cotton Quotation and replace the references...
Viscoelastic analysis of seals for extended service life
NASA Technical Reports Server (NTRS)
Bower, Mark V.
1993-01-01
The space station is being developed for a service life of up to thirty years. As a consequence, the design requirements for the seals to be used are unprecedented. Full scale testing to assure the selected seals can satisfy the design requirements are not feasible. As an alternative, a sub-scale test program (2) has been developed by MSFC to calibrate the analysis tools to be used to certify the proposed design. This research has been conducted in support of the MSFC Integrated Seal Test Program. The ultimate objective of this research is to correlate analysis and test results to qualify the analytical tools which in turn, are to be used to qualify the flight hardware. Seals are simple devices, in wide spread use. The most common type of seal is the O-ring. O-ring seals are typically rings of rubber with a circular cross section. The rings are placed between the surfaces to be sealed, usually in a groove of some design. The particular design may differ based on a number of different factors. This research is focused on O-rings that are staticly compressed by perpendicular clamping forces, commonly referred to as face seals. In this type of seal the O-ring is clamped between the sealing surfaces by loads perpendicular to the circular cross section.
Design integration for minimal energy and cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halldane, J.E.
The authors present requirements for creating alternative energy conserving designs including energy management and architectural, plumbing, mechanical, electrical, electronic and optical design. Parameters of power, energy, life cycle costs and benefit for resource for an evaluation by the interested parties are discussed. They present an analysis of power systems through a seasonal power distribution diagram. An analysis of cost systems includes capital cost from the power components, annual costs from the utility energy use, and finance costs with loans, taxes, settlement and design fees. Equations are transposed to the evaluative parameter and are uniquely explicit with consistent symbols, parameter definitions,more » dual and balanced units, unit conversions, criteria for operation, incorporated constants for rapid calculations, references to data in the handbook, other common terms, and instrumentation for the measurement. Each component equation has a key power diagram.« less
Searching for missing heritability: Designing rare variant association studies
Zuk, Or; Schaffner, Stephen F.; Samocha, Kaitlin; Do, Ron; Hechter, Eliana; Kathiresan, Sekar; Daly, Mark J.; Neale, Benjamin M.; Sunyaev, Shamil R.; Lander, Eric S.
2014-01-01
Genetic studies have revealed thousands of loci predisposing to hundreds of human diseases and traits, revealing important biological pathways and defining novel therapeutic hypotheses. However, the genes discovered to date typically explain less than half of the apparent heritability. Because efforts have largely focused on common genetic variants, one hypothesis is that much of the missing heritability is due to rare genetic variants. Studies of common variants are typically referred to as genomewide association studies, whereas studies of rare variants are often simply called sequencing studies. Because they are actually closely related, we use the terms common variant association study (CVAS) and rare variant association study (RVAS). In this paper, we outline the similarities and differences between RVAS and CVAS and describe a conceptual framework for the design of RVAS. We apply the framework to address key questions about the sample sizes needed to detect association, the relative merits of testing disruptive alleles vs. missense alleles, frequency thresholds for filtering alleles, the value of predictors of the functional impact of missense alleles, the potential utility of isolated populations, the value of gene-set analysis, and the utility of de novo mutations. The optimal design depends critically on the selection coefficient against deleterious alleles and thus varies across genes. The analysis shows that common variant and rare variant studies require similarly large sample collections. In particular, a well-powered RVAS should involve discovery sets with at least 25,000 cases, together with a substantial replication set. PMID:24443550
Broadband set-top box using MAP-CA processor
NASA Astrophysics Data System (ADS)
Bush, John E.; Lee, Woobin; Basoglu, Chris
2001-12-01
Advances in broadband access are expected to exert a profound impact in our everyday life. It will be the key to the digital convergence of communication, computer and consumer equipment. A common thread that facilitates this convergence comprises digital media and Internet. To address this market, Equator Technologies, Inc., is developing the Dolphin broadband set-top box reference platform using its MAP-CA Broadband Signal ProcessorT chip. The Dolphin reference platform is a universal media platform for display and presentation of digital contents on end-user entertainment systems. The objective of the Dolphin reference platform is to provide a complete set-top box system based on the MAP-CA processor. It includes all the necessary hardware and software components for the emerging broadcast and the broadband digital media market based on IP protocols. Such reference design requires a broadband Internet access and high-performance digital signal processing. By using the MAP-CA processor, the Dolphin reference platform is completely programmable, allowing various codecs to be implemented in software, such as MPEG-2, MPEG-4, H.263 and proprietary codecs. The software implementation also enables field upgrades to keep pace with evolving technology and industry demands.
CisLunar Habitat Internal Architecture Design Criteria
NASA Technical Reports Server (NTRS)
Jones, R.; Kennedy, K.; Howard, R.; Whitmore, M.; Martin, C.; Garate, J.
2017-01-01
BACKGROUND: In preparation for human exploration to Mars, there is a need to define the development and test program that will validate deep space operations and systems. In that context, a Proving Grounds CisLunar habitat spacecraft is being defined as the next step towards this goal. This spacecraft will operate differently from the ISS or other spacecraft in human history. The performance envelope of this spacecraft (mass, volume, power, specifications, etc.) is being defined by the Future Capabilities Study Team. This team has recognized the need for a human-centered approach for the internal architecture of this spacecraft and has commissioned a CisLunar Phase-1 Habitat Internal Architecture Study Team to develop a NASA reference configuration, providing the Agency with a "smart buyer" approach for future acquisition. THE CISLUNAR HABITAT INTERNAL ARCHITECTURE STUDY: Overall, the CisLunar Habitat Internal Architecture study will address the most significant questions and risks in the current CisLunar architecture, habitation, and operations concept development. This effort is achieved through definition of design criteria, evaluation criteria and process, design of the CisLunar Habitat Phase-1 internal architecture, and the development and fabrication of internal architecture concepts combined with rigorous and methodical Human-in-the-Loop (HITL) evaluations and testing of the conceptual innovations in a controlled test environment. The vision of the CisLunar Habitat Internal Architecture Study is to design, build, and test a CisLunar Phase-1 Habitat Internal Architecture that will be used for habitation (e.g. habitability and human factors) evaluations. The evaluations will mature CisLunar habitat evaluation tools, guidelines, and standards, and will interface with other projects such as the Advanced Exploration Systems (AES) Program integrated Power, Avionics, Software (iPAS), and Logistics for integrated human-in-the-loop testing. The mission of the CisLunar Habitat Internal Architecture Study is to become a forcing function to establish a common understanding of CisLunar Phase-1 Habitation Internal Architecture design criteria, processes, and tools. The scope of the CisLunar Habitat Internal Architecture study is to design, develop, demonstrate, and evaluate a Phase-1 CisLunar Habitat common module internal architecture based on design criteria agreed to by NASA, the International Partners, and Commercial Exploration teams. This task is to define the CisLunar Phase-1 Internal Architecture Government Reference Design, assist NASA in becoming a "smart buyer" for Phase-1 Habitat Concepts, and ultimately to derive standards and requirements from the Internal Architecture Design Process. The first step was to define a Habitat Internal Architecture Design Criteria and create a structured philosophy to be used by design teams as a filter by which critical aspects of consideration would be identified for the purpose of organizing and utilizing interior spaces. With design criteria in place, the team will develop a series of iterative internal architecture concept designs which will be assessed by means of an evaluation criteria and process. These assessments will successively drive and refine the design, leading to the combination and down-selection of design concepts. A single refined reference design configuration will be developed into in a medium-to-high fidelity mockup. A multi-day human-in-the-loop mission test will fully evaluate the reference design and validate its configuration. Lessons learned from the design and evaluation will enable the team to identify appropriate standards for Phase-1 CisLunar Habitat Internal Architecture and will enable NASA to develop derived requirements in support of maturing CisLunar Habitation capabilities. This paper will describe the criteria definition process, workshop event, and resulting CisLunar Phase-1 Habitat Internal Architecture Design Criteria.
Common path ball lens probe for optical coherence tomography (Conference Presentation)
NASA Astrophysics Data System (ADS)
Singh, Kanwarpal; Yamada, Daisuke; Tearney, Guillermo J.
2016-02-01
Background: Common path probes are highly desirable for optical coherence tomography (OCT) as they reduce system complexity and cost. In this work we report an all-fiber common path side viewing monolithic probe for coronary artery imaging. Methods: Our common path probe was designed for spectrometer based Fourier domain OCT at 1310 nm wavelength. Light from the fiber expands in the coreless fiber region and then focussed by the ball lens. Reflection from ball lens-air interface served as reference signal. The monolithic ball lens probe was assembled within a 560 µmouter diameter drive shaft which was attached to a rotary junction. The drive shaft was placed inside an outer, transparent sheath of 800 µm diameter. Results: With a source input power of 25 mW, we could achieve sensitivity of 100.5 dB. The axial resolution of the system was found to be 15.6 µm in air and the lateral resolution (full width half maximum) was approximately 49 µm. As proof of principal, images of skin acquired using this probe demonstrated clear visualization of the stratum corneum, epidermis, and papillary dermis, along with sweat ducts. Conclusion: In this work we have demonstrated a monolithic, ball lens common, path probe for OCT imaging. The designed ball lens probe is easy to fabricate using a laser splicer. Based on the features and capability of common path probes to provide a simpler solution for OCT, we believe that this development will be an important enhancement for certain types of catheters.
Teasdale, G. M.; Hadley, D. M.; Lawrence, A.; Bone, I.; Burton, H.; Grant, R.; Condon, B.; Macpherson, P.; Rowan, J.
1989-01-01
OBJECTIVE--To compare computed tomography and magnetic resonance imaging in investigating patients suspected of having a lesion in the posterior cranial fossa. DESIGN--Randomised allocation of newly referred patients to undergo either computed tomography or magnetic resonance imaging; the alternative investigation was performed subsequently only in response to a request from the referring doctor. SETTING--A regional neuroscience centre serving 2.7 million. PATIENTS--1020 Patients recruited between April 1986 and December 1987, all suspected by neurologists, neurosurgeons, or other specialists of having a lesion in the posterior fossa and referred for neuroradiology. The groups allocated to undergo computed tomography or magnetic resonance imaging were well matched in distributions of age, sex, specialty of referring doctor, investigation as an inpatient or an outpatient, suspected site of lesion, and presumed disease process; the referring doctor's confidence in the initial clinical diagnosis was also similar. INTERVENTIONS--After the patients had been imaged by either computed tomography or magnetic resonance (using a resistive magnet of 0.15 T) doctors were given the radiologist's report and a form asking if they considered that imaging with the alternative technique was necessary and, if so, why; it also asked for their current diagnoses and their confidence in them. MAIN OUTCOME MEASURES--Number of requests for the alternative method of investigation. Assessment of characteristics of patients for whom further imaging was requested and lesions that were suspected initially and how the results of the second imaging affected clinicians' and radiologists' opinions. RESULTS--Ninety three of the 501 patients who initially underwent computed tomography were referred subsequently for magnetic resonance imaging whereas only 28 of the 493 patients who initially underwent magnetic resonance imaging were referred subsequently for computed tomography. Over the study the number of patients referred for magnetic resonance imaging after computed tomography increased but requests for computed tomography after magnetic resonance imaging decreased. The reason that clinicians gave most commonly for requesting further imaging by magnetic resonance was that the results of the initial computed tomography failed to exclude their suspected diagnosis (64 patients). This was less common in patients investigated initially by magnetic resonance imaging (eight patients). Management of 28 patients (6%) imaged initially with computed tomography and 12 patients (2%) imaged initially with magnetic resonance was changed on the basis of the results of the alternative imaging. CONCLUSIONS--Magnetic resonance imaging provided doctors with the information required to manage patients suspected of having a lesion in the posterior fossa more commonly than computed tomography, but computed tomography alone was satisfactory in 80% of cases... PMID:2506965
Peer education in the commons: a new approach to reference services.
Neal, Ruth E; Ajamie, Lauren F; Harmon, Karen D; Kellerby, Carissa D; Schweikhard, April J
2010-10-01
In planning for a new library construction project for the University of Oklahoma-Tulsa, graduate students enrolled in the University of Oklahoma (OU) School of Library and Information Studies collaborated in an innovative effort to develop a commons-based reference service. By first considering a philosophical approach to the need for a commons, blending in the experiences of other libraries that have created similar spaces, and focusing on the workflow issues likely to be encountered by the graduate assistants staffing the commons itself, this planning team developed an uncommon peer-to-peer approach to reference and education services, one focused on the patron as student.
Geriatric Syndromes in Hospitalized Older Adults Discharged to Skilled Nursing Facilities
Bell, Susan P.; Vasilevskis, Eduard E.; Saraf, Avantika A.; Jacobsen, J. Mary Lou; Kripalani, Sunil; Mixon, Amanda S.; Schnelle, John F.; Simmons, Sandra F.
2016-01-01
Background Geriatric syndromes are common in older adults and associated with adverse outcomes. The prevalence, recognition, co-occurrence and recent onset of geriatric syndromes in patients transferred from hospital to skilled nursing facilities (SNFs) are largely unknown. Design Quality improvement project. Setting Acute care academic medical center and 23 regional partner SNFs. Participants 686 Medicare beneficiaries hospitalized between January 2013 and April 2014 and referred to SNFs. Measurements Nine geriatric syndromes were measured by project staff -- weight loss, decreased appetite, incontinence and pain (standardized interview), depression (Geriatric Depression Scale), delirium (Brief-Confusion Assessment Method), cognitive impairment (Brief Interview for Mental Status), falls and pressure ulcers (hospital medical record utilizing hospital-implemented screening tools). Estimated prevalence, new-onset prevalence and common coexisting clusters were determined. The extent that syndromes were commonly recognized by treating physicians and communicated to SNFs in hospital discharge documentation was evaluated. Results Geriatric syndromes were prevalent in more than 90% of hospitalized adults referred to SNFs; 55% met criteria for 3 or more co-existing syndromes. Overall the most prevalent syndromes were falls (39%), incontinence (39%), decreased appetite (37%) and weight loss (33%). Of individuals that met criteria for 3 or more syndromes, the most common triad clusters included nutritional syndromes (weight loss, loss of appetite), incontinence and depression. Treating hospital physicians commonly did not recognize and document geriatric syndromes in discharge summaries, missing 33–95% of syndromes present as assessed by research personnel. Conclusion Geriatric syndromes in hospitalized older adults transferred to SNF are prevalent and commonly co-exist with the most frequent clusters including nutritional syndromes, depression and incontinence. Despite the high prevalence, this clinical information is rarely communicated to the SNF on discharge. PMID:27059831
Empirical Learner Language and the Levels of the "Common European Framework of Reference"
ERIC Educational Resources Information Center
Wisniewski, Katrin
2017-01-01
The "Common European Framework of Reference" (CEFR) is the most widespread reference tool for linking language tests, curricula, and national educational standards to levels of foreign language proficiency in Europe. In spite of this, little is known about how the CEFR levels (A1-C2) relate to empirical learner language(s). This article…
The Design of a Propeller for a U.S. Coast Guard Icebreaker Tugboat
1975-10-01
series as investigated by Van Lammeren, Van Manen , and Oosterveld . This propeller series, commonly referred to as the K’jgeningen B-screw series...RtFEKENCES Van Lammeren, W.P.A., Van Manen , J.D., and Oosterveld, M.W.C., "The Wageningen B-Screw Series," Transactions of the Society of Naval Architects...forces has been reported by Van Gunsteren and Pronk . They investigated both single and twin screw ships of various types and the results are
The marketing of dissolvable tobacco: social science and public policy research needs.
Southwell, Brian G; Kim, Annice E; Tessman, Greta K; MacMonegle, Anna J; Choiniere, Conrad J; Evans, Sarah E; Johnson, Robin D
2012-01-01
The latest generation of smokeless tobacco products encompasses a wide range of offerings, including what is commonly referred to as dissolvable tobacco. Designed to deliver nicotine upon dissolving or disintegrating in a user's mouth, dissolvable tobacco products currently appear in various United States markets as strips, orbs, sticks, and lozenges. The emergence of these new products poses distinct opportunities and challenges for social and behavioral science and public health research and raises important public policy questions.
Critical early mission design considerations for lunar data systems architecture
NASA Technical Reports Server (NTRS)
Hei, Donald J., Jr.; Stephens, Elaine
1992-01-01
This paper outlines recent early mission design activites for a lunar data systems architecture. Each major functional element is shown to be strikingly similar when viewed in a common reference system. While this similarity probably deviates with lower levels of decomposition, the sub-functions can always be arranged into similar and dissimilar categories. Similar functions can be implemented as objects - implemented once and reused several times like today's advanced integrated circuits. This approach to mission data systems, applied to other NASA programs, may result in substantial agency implementation and maintenance savings. In today's zero-sum-game budgetary environment, this approach could help to enable a lunar exploration program in the next decade. Several early mission studies leading to such an object-oriented data systems design are recommended.
Optimal chroma-like channel design for passive color image splicing detection
NASA Astrophysics Data System (ADS)
Zhao, Xudong; Li, Shenghong; Wang, Shilin; Li, Jianhua; Yang, Kongjin
2012-12-01
Image splicing is one of the most common image forgeries in our daily life and due to the powerful image manipulation tools, image splicing is becoming easier and easier. Several methods have been proposed for image splicing detection and all of them worked on certain existing color channels. However, the splicing artifacts vary in different color channels and the selection of color model is important for image splicing detection. In this article, instead of finding an existing color model, we propose a color channel design method to find the most discriminative channel which is referred to as optimal chroma-like channel for a given feature extraction method. Experimental results show that both spatial and frequency features extracted from the designed channel achieve higher detection rate than those extracted from traditional color channels.
Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György
2018-01-01
Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.
Feng, Zhao; Ling, Jie; Ming, Min; Xiao, Xiao-Hui
2017-08-01
For precision motion, high-bandwidth and flexible tracking are the two important issues for significant performance improvement. Iterative learning control (ILC) is an effective feedforward control method only for systems that operate strictly repetitively. Although projection ILC can track varying references, the performance is still limited by the fixed-bandwidth Q-filter, especially for triangular waves tracking commonly used in a piezo nanopositioner. In this paper, a wavelet transform-based linear time-varying (LTV) Q-filter design for projection ILC is proposed to compensate high-frequency errors and improve the ability to tracking varying references simultaneously. The LVT Q-filter is designed based on the modulus maximum of wavelet detail coefficients calculated by wavelet transform to determine the high-frequency locations of each iteration with the advantages of avoiding cross-terms and segmenting manually. The proposed approach was verified on a piezo nanopositioner. Experimental results indicate that the proposed approach can locate the high-frequency regions accurately and achieve the best performance under varying references compared with traditional frequency-domain and projection ILC with a fixed-bandwidth Q-filter, which validates that through implementing the LTV filter on projection ILC, high-bandwidth and flexible tracking can be achieved simultaneously by the proposed approach.
Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao
2013-01-01
Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat.
Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao
2013-01-01
Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat. PMID:24098735
Effect of EEG Referencing Methods on Auditory Mismatch Negativity
Mahajan, Yatin; Peter, Varghese; Sharma, Mridula
2017-01-01
Auditory event-related potentials (ERPs) have consistently been used in the investigation of auditory and cognitive processing in the research and clinical laboratories. There is currently no consensus on the choice of appropriate reference for auditory ERPs. The most commonly used references in auditory ERP research are the mathematically linked-mastoids (LM) and average referencing (AVG). Since LM and AVG referencing procedures do not solve the issue of electrically-neutral reference, Reference Electrode Standardization Technique (REST) was developed to create a neutral reference for EEG recordings. The aim of the current research is to compare the influence of the reference on amplitude and latency of auditory mismatch negativity (MMN) as a function of magnitude of frequency deviance across three commonly used electrode montages (16, 32, and 64-channel) using REST, LM, and AVG reference procedures. The current study was designed to determine if the three reference methods capture the variation in amplitude and latency of MMN with the deviance magnitude. We recorded MMN from 12 normal hearing young adults in an auditory oddball paradigm with 1,000 Hz pure tone as standard and 1,030, 1,100, and 1,200 Hz as small, medium and large frequency deviants, respectively. The EEG data recorded to these sounds was re-referenced using REST, LM, and AVG methods across 16-, 32-, and 64-channel EEG electrode montages. Results revealed that while the latency of MMN decreased with increment in frequency of deviant sounds, no effect of frequency deviance was present for amplitude of MMN. There was no effect of referencing procedure on the experimental effect tested. The amplitude of MMN was largest when the ERP was computed using LM referencing and the REST referencing produced the largest amplitude of MMN for 64-channel montage. There was no effect of electrode-montage on AVG referencing induced ERPs. Contrary to our predictions, the results suggest that the auditory MMN elicited as a function of increments in frequency deviance does not depend on the choice of referencing procedure. The results also suggest that auditory ERPs generated using REST referencing is contingent on the electrode arrays more than the AVG referencing. PMID:29066945
Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.
Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon
2016-05-01
Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.
Anatomical information in radiation treatment planning.
Kalet, I J; Wu, J; Lease, M; Austin-Seymour, M M; Brinkley, J F; Rosse, C
1999-01-01
We report on experience and insights gained from prototyping, for clinical radiation oncologists, a new access tool for the University of Washington Digital Anatomist information resources. This access tool is designed to integrate with a radiation therapy planning (RTP) system in use in a clinical setting. We hypothesize that the needs of practitioners in a clinical setting are different from the needs of students, the original targeted users of the Digital Anatomist system, but that a common knowledge resource can serve both. Our prototype was designed to help define those differences and study the feasibility of a full anatomic reference system that will support both clinical radiation therapy and all the existing educational applications.
Hand controllers for teleoperation. A state-of-the-art technology survey and evaluation
NASA Technical Reports Server (NTRS)
Brooks, T. L.; Bejczy, A. K.
1985-01-01
Hand controller technology for teleoperation is surveyed in three major catagories: (1) hand grip design, (2) control input devices, and (3) control strategies. In the first category, 14 hand grip designs are reviewed and evaluated in light of human factor considerations. In the second, 12 hand controller input devices are evaluated in terms of task performance, configuration and force feedback, controller/slave correspondence, operating volume, operator workload, human limitations, cross coupling, singularities, anthropomorphic characteristics, physical complexity, control/display interference, accuracy, technological base, cost, and reliability. In the third catagory, control strategies, commonly called control modes, are surveyed and evaluated. The report contains a bibliography with 189 select references on hand controller technology.
Evaluation of Human and AutomationRobotics Integration Needs for Future Human Exploration Missions
NASA Technical Reports Server (NTRS)
Marquez, Jessica J.; Adelstein, Bernard D.; Ellis, Stephen; Chang, Mai Lee; Howard, Robert
2016-01-01
NASA employs Design Reference Missions (DRMs) to define potential architectures for future human exploration missions to deep space, the Moon, and Mars. While DRMs to these destinations share some components, each mission has different needs. This paper focuses on the human and automation/robotic integration needs for these future missions, evaluating them with respect to NASA research gaps in the area of space human factors engineering. The outcomes of our assessment is a human and automation/robotic (HAR) task list for each of the four DRMs that we reviewed (i.e., Deep Space Sortie, Lunar Visit/Habitation, Deep Space Habitation, and Planetary), a list of common critical HAR factors that drive HAR design.
The interdependence between screening methods and screening libraries.
Shelat, Anang A; Guy, R Kiplin
2007-06-01
The most common methods for discovery of chemical compounds capable of manipulating biological function involves some form of screening. The success of such screens is highly dependent on the chemical materials - commonly referred to as libraries - that are assayed. Classic methods for the design of screening libraries have depended on knowledge of target structure and relevant pharmacophores for target focus, and on simple count-based measures to assess other properties. The recent proliferation of two novel screening paradigms, structure-based screening and high-content screening, prompts a profound rethink about the ideal composition of small-molecule screening libraries. We suggest that currently utilized libraries are not optimal for addressing new targets by high-throughput screening, or complex phenotypes by high-content screening.
Liu, Yu; Koyutürk, Mehmet; Maxwell, Sean; Xiang, Min; Veigl, Martina; Cooper, Richard S; Tayo, Bamidele O; Li, Li; LaFramboise, Thomas; Wang, Zhenghe; Zhu, Xiaofeng; Chance, Mark R
2014-08-16
Sequences up to several megabases in length have been found to be present in individual genomes but absent in the human reference genome. These sequences may be common in populations, and their absence in the reference genome may indicate rare variants in the genomes of individuals who served as donors for the human genome project. As the reference genome is used in probe design for microarray technology and mapping short reads in next generation sequencing (NGS), this missing sequence could be a source of bias in functional genomic studies and variant analysis. One End Anchor (OEA) and/or orphan reads from paired-end sequencing have been used to identify novel sequences that are absent in reference genome. However, there is no study to investigate the distribution, evolution and functionality of those sequences in human populations. To systematically identify and study the missing common sequences (micSeqs), we extended the previous method by pooling OEA reads from large number of individuals and applying strict filtering methods to remove false sequences. The pipeline was applied to data from phase 1 of the 1000 Genomes Project. We identified 309 micSeqs that are present in at least 1% of the human population, but absent in the reference genome. We confirmed 76% of these 309 micSeqs by comparison to other primate genomes, individual human genomes, and gene expression data. Furthermore, we randomly selected fifteen micSeqs and confirmed their presence using PCR validation in 38 additional individuals. Functional analysis using published RNA-seq and ChIP-seq data showed that eleven micSeqs are highly expressed in human brain and three micSeqs contain transcription factor (TF) binding regions, suggesting they are functional elements. In addition, the identified micSeqs are absent in non-primates and show dynamic acquisition during primate evolution culminating with most micSeqs being present in Africans, suggesting some micSeqs may be important sources of human diversity. 76% of micSeqs were confirmed by a comparative genomics approach. Fourteen micSeqs are expressed in human brain or contain TF binding regions. Some micSeqs are primate-specific, conserved and may play a role in the evolution of primates.
NASA Astrophysics Data System (ADS)
Kluger-Bell, B.
2010-12-01
The term "Inquiry Starter" comes from the Institute for Inquiry's model for teaching and learning science through inquiry. It refers to the first phase of an inquiry activity where learners engage in actions that stimulate their curiosity and generate questions for further investigation. In the Professional Development Program, staff and participants have designed a wide variety of inquiry activities with a number of variations on the inquiry starter. This has provided a laboratory for examining inquiry starter design. In this paper, I describe and examine in detail the elements of this design and how the design of those elements is related to achieving learning objectives. There are a number of important common objectives in all inquiry starters. For example, all starters must define a domain for investigation and engage the learner's curiosity in that domain. There are also critical differences in learning objectives depending on the content area being studied, the learners' background knowledge and skills, and many other factors. In this paper I examine designs for both of these types of objectives.
System engineering toolbox for design-oriented engineers
NASA Technical Reports Server (NTRS)
Goldberg, B. E.; Everhart, K.; Stevens, R.; Babbitt, N., III; Clemens, P.; Stout, L.
1994-01-01
This system engineering toolbox is designed to provide tools and methodologies to the design-oriented systems engineer. A tool is defined as a set of procedures to accomplish a specific function. A methodology is defined as a collection of tools, rules, and postulates to accomplish a purpose. For each concept addressed in the toolbox, the following information is provided: (1) description, (2) application, (3) procedures, (4) examples, if practical, (5) advantages, (6) limitations, and (7) bibliography and/or references. The scope of the document includes concept development tools, system safety and reliability tools, design-related analytical tools, graphical data interpretation tools, a brief description of common statistical tools and methodologies, so-called total quality management tools, and trend analysis tools. Both relationship to project phase and primary functional usage of the tools are also delineated. The toolbox also includes a case study for illustrative purposes. Fifty-five tools are delineated in the text.
Beam masking to reduce cyclic error in beam launcher of interferometer
NASA Technical Reports Server (NTRS)
Ames, Lawrence L. (Inventor); Bell, Raymond Mark (Inventor); Dutta, Kalyan (Inventor)
2005-01-01
Embodiments of the present invention are directed to reducing cyclic error in the beam launcher of an interferometer. In one embodiment, an interferometry apparatus comprises a reference beam directed along a reference path, and a measurement beam spatially separated from the reference beam and being directed along a measurement path contacting a measurement object. The reference beam and the measurement beam have a single frequency. At least a portion of the reference beam and at least a portion of the measurement beam overlapping along a common path. One or more masks are disposed in the common path or in the reference path and the measurement path to spatially isolate the reference beam and the measurement beam from one another.
ERIC Educational Resources Information Center
Normand-Marconnet, Nadine; Lo Bianco, Joseph
2015-01-01
Today, the "Common European Framework of Reference for Languages" (CEFR; Council of Europe 2001) is widely recognised as emblematic of globalization in education, both in the realms of policy and in educational practice (Byram et al. 2012a). In Europe the CEFR is regularly cited as a reference point for curriculum planning, and is often…
Verification bias an underrecognized source of error in assessing the efficacy of medical imaging.
Petscavage, Jonelle M; Richardson, Michael L; Carr, Robert B
2011-03-01
Diagnostic tests are validated by comparison against a "gold standard" reference test. When the reference test is invasive or expensive, it may not be applied to all patients. This can result in biased estimates of the sensitivity and specificity of the diagnostic test. This type of bias is called "verification bias," and is a common problem in imaging research. The purpose of our study is to estimate the prevalence of verification bias in the recent radiology literature. All issues of the American Journal of Roentgenology (AJR), Academic Radiology, Radiology, and European Journal of Radiology (EJR) between November 2006 and October 2009 were reviewed for original research articles mentioning sensitivity or specificity as endpoints. Articles were read to determine whether verification bias was present and searched for author recognition of verification bias in the design. During 3 years, these journals published 2969 original research articles. A total of 776 articles used sensitivity or specificity as an outcome. Of these, 211 articles demonstrated potential verification bias. The fraction of articles with potential bias was respectively 36.4%, 23.4%, 29.5%, and 13.4% for AJR, Academic Radiology, Radiology, and EJR. The total fraction of papers with potential bias in which the authors acknowledged this bias was 17.1%. Verification bias is a common and frequently unacknowledged source of error in efficacy studies of diagnostic imaging. Bias can often be eliminated by proper study design. When it cannot be eliminated, it should be estimated and acknowledged. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Min, David B.; Ellefson, Wayne C.
Lipids, proteins, and carbohydrates constitute the principal structural components of foods. Lipids are a group of substances that, in general, are soluble in ether, chloroform, or other organic solvents but are sparingly soluble in water. However, there exists no clear scientific definition of a lipid, primarily due to the water solubility of certain molecules that fall within one of the variable categories of food lipids (1). Some lipids, such as triacylglycerols, are very hydrophobic. Other lipids, such as di- and monoacylglycerols, have both hydrophobic and hydrophilic moieties in their molecules and are soluble in relatively polar solvents (2). Short-chain fatty acids such as C1-C4 are completely miscible in water and insoluble in nonpolar solvents (1). The most widely accepted definition is based on solubility as previously stated. While most macromolecules are characterized by common structural features, the designation of "lipid" being defined by solubility characteristics is unique to lipids (2). Lipids comprise a broad group of substances that have some common properties and compositional similarities (3). Triacylglycerols are fats and oils that represent the most prevalent category of the group of compounds known as lipids. The terms lipids, fats, and oils are often used interchangeably. The term "lipid" commonly refers to the broad, total collection of food molecules that meet the definition previously stated. Fats generally refer to those lipids that are solid at room temperature and oils generally refer to those lipids that are liquid at room temperature. While there may not be an exact scientific definition, the US Food and Drug Administration (FDA) has established a regulatory definition for nutrition labeling purposes. The FDA has defined total fat as the sum of fatty acids from C4 to C24, calculated as triglycerides. This definition provides a clear path for resolution of any nutrition labeling disputes.
Genotyping Brahman cattle for generalised glycogenosis.
Dennis, J A; Healy, P J; Reichmann, K G
2002-05-01
To develop procedures for genotyping Brahman cattle for loss-of-function alleles within the acidic alpha-glucosidase gene and to assess the risk of generalised glycogenosis in Australian Brahman cattle. PCR assays for three loss-of-function alleles were designed to exploit internal restriction sites within acidic alpha-glucosidase amplicons that are independent of allelic variants at the mutant sites. Genotyping 8529 clinically normal Brahmans between August 1996 and August 2001 revealed 16.4% were heterozygous for the more common of the two mutations (1057deltaTA, often referred to as the 'E7' mutation) that cause generalised glycogenosis in this breed. The less common 1783T mutation (often referred to as the 'E13' mutation) was restricted to descendants of one imported bull, and was not detected in 600 randomly selected Brahmans. Prior to definition of these two disease-causing mutations, 640 (18%), and 14 (0.4%), of 3559 clinically normal Brahmans analysed between January 1994 and December 1996, were heterozygous, and homozygous, respectively, for a silent polymorphism (2223G-->A) that is associated with generalised glycogenosis. In addition to the 1057deltaTA and 1783T mutations, approximately 15% of Brahmans were found to be heterozygous for a single base substitution in exon 9 (1351T, commonly referred to as the 'E9' mutation) that significantly reduces acidic alpha-glucosidase activity, but has not been associated with clinical disease. These three loss-of-function alleles were found in Brahmans imported, or selected for import, from the USA. The PCR procedures reported here represent a significant improvement in reliability and accuracy over previous published methods. Utilisation of these PCR/restriction enzyme based assays will facilitate precise selection against the 1057deltaTA and 1783T alleles, and consequently reduce the incidence of generalised glycogenosis in registered and commercial Brahman herds.
Clinical Characteristics of Patients With Cancer Referred for Outpatient Physical Therapy
Coronado, Rogelio A.; Lee, Derek; Bour, Barbara; George, Steven Z.
2015-01-01
Background Cancer rehabilitation is a developing area, with an increasing number of survivors of cancer in the United States. The increase in survivorship occurs alongside impairments arising directly from cancer or from treatment-related side effects. Objective This study described clinical characteristics of patients with cancer referred for outpatient physical therapy and explored patterns in frequency of impairments between type of cancer and mode of cancer treatment. Design This was a retrospective chart review of patients with cancer referred to a tertiary care physical therapy clinic over a 2-year period. Methods Characteristics such as age, sex, cancer type, mode of treatment, and neuromusculoskeletal impairments were identified. Impairment frequencies were computed based on cancer type and mode of treatment. Results Data from 418 patients (mean age=57.9 years, SD=14.3; 41.1% female) were examined. Genitourinary cancer (n=169) and breast cancer (n=90) were the most prevalent types of cancer reported in this sample. Impairments in strength (83.6%) and soft tissue (71.3%) were the most common examination findings. Lymphedema was most common in patients with breast cancer, and incontinence was most common in patients with genitourinary cancer. Limitations The types of cancer identified in this study may be reflective of this tertiary center and may not generalize to other facilities. Impairment identification during the initial physical therapist evaluation was not performed systematically. Conclusion These data reinforce that physical therapists should screen for lymphedema in patients with breast cancer and incontinence in urogenital cancers. Strength and soft tissue integrity should be evaluated in most patients with cancer. Assessing pain and fatigue levels is recommended for patients who have had radiation therapy. PMID:25504482
Wang, Peng; Zhang, Cheng; Liu, Hong-Wen; Xiong, Mengyi; Yin, Sheng-Yan; Yang, Yue; Hu, Xiao-Xiao; Yin, Xia; Zhang, Xiao-Bing; Tan, Weihong
2017-12-01
Fluorescence quantitative analyses for vital biomolecules are in great demand in biomedical science owing to their unique detection advantages with rapid, sensitive, non-damaging and specific identification. However, available fluorescence strategies for quantitative detection are usually hard to design and achieve. Inspired by supramolecular chemistry, a two-photon-excited fluorescent supramolecular nanoplatform ( TPSNP ) was designed for quantitative analysis with three parts: host molecules (β-CD polymers), a guest fluorophore of sensing probes (Np-Ad) and a guest internal reference (NpRh-Ad). In this strategy, the TPSNP possesses the merits of (i) improved water-solubility and biocompatibility; (ii) increased tissue penetration depth for bioimaging by two-photon excitation; (iii) quantitative and tunable assembly of functional guest molecules to obtain optimized detection conditions; (iv) a common approach to avoid the limitation of complicated design by adjustment of sensing probes; and (v) accurate quantitative analysis by virtue of reference molecules. As a proof-of-concept, we utilized the two-photon fluorescent probe NHS-Ad-based TPSNP-1 to realize accurate quantitative analysis of hydrogen sulfide (H 2 S), with high sensitivity and good selectivity in live cells, deep tissues and ex vivo -dissected organs, suggesting that the TPSNP is an ideal quantitative indicator for clinical samples. What's more, TPSNP will pave the way for designing and preparing advanced supramolecular sensors for biosensing and biomedicine.
A First Look at the Upcoming SISO Space Reference FOM
NASA Technical Reports Server (NTRS)
Mueller, Bjorn; Crues, Edwin Z.; Dexter, Dan; Garro, Alfredo; Skuratovskiy, Anton; Vankov, Alexander
2016-01-01
Spaceflight is difficult, dangerous and expensive; human spaceflight even more so. In order to mitigate some of the danger and expense, professionals in the space domain have relied, and continue to rely, on computer simulation. Simulation is used at every level including concept, design, analysis, construction, testing, training and ultimately flight. As space systems have grown more complex, new simulation technologies have been developed, adopted and applied. Distributed simulation is one those technologies. Distributed simulation provides a base technology for segmenting these complex space systems into smaller, and usually simpler, component systems or subsystems. This segmentation also supports the separation of responsibilities between participating organizations. This segmentation is particularly useful for complex space systems like the International Space Station (ISS), which is composed of many elements from many nations along with visiting vehicles from many nations. This is likely to be the case for future human space exploration activities. Over the years, a number of distributed simulations have been built within the space domain. While many use the High Level Architecture (HLA) to provide the infrastructure for interoperability, HLA without a Federation Object Model (FOM) is insufficient by itself to insure interoperability. As a result, the Simulation Interoperability Standards Organization (SISO) is developing a Space Reference FOM. The Space Reference FOM Product Development Group is composed of members from several countries. They contribute experiences from projects within NASA, ESA and other organizations and represent government, academia and industry. The initial version of the Space Reference FOM is focusing on time and space and will provide the following: (i) a flexible positioning system using reference frames for arbitrary bodies in space, (ii) a naming conventions for well-known reference frames, (iii) definitions of common time scales, (iv) federation agreements for common types of time management with focus on time stepped simulation, and (v) support for physical entities, such as space vehicles and astronauts. The Space Reference FOM is expected to make collaboration politically, contractually and technically easier. It is also expected to make collaboration easier to manage and extend.
International Docking Standard (IDSS) Interface Definition Document (IDD) . E; Revision
NASA Technical Reports Server (NTRS)
Kelly, Sean M.; Cryan, Scott P.
2016-01-01
This International Docking System Standard (IDSS) Interface Definition Document (IDD) is the result of a collaboration by the International Space Station membership to establish a standard docking interface to enable on-orbit crew rescue operations and joint collaborative endeavors utilizing different spacecraft. This IDSS IDD details the physical geometric mating interface and design loads requirements. The physical geometric interface requirements must be strictly followed to ensure physical spacecraft mating compatibility. This includes both defined components and areas that are void of components. The IDD also identifies common design parameters as identified in section 3.0, e.g., docking initial conditions and vehicle mass properties. This information represents a recommended set of design values enveloping a broad set of design reference missions and conditions, which if accommodated in the docking system design, increases the probability of successful docking between different spacecraft. This IDD does not address operational procedures or off-nominal situations, nor does it dictate implementation or design features behind the mating interface. It is the responsibility of the spacecraft developer to perform all hardware verification and validation, and to perform final docking analyses to ensure the needed docking performance and to develop the final certification loads for their application. While there are many other critical requirements needed in the development of a docking system such as fault tolerance, reliability, and environments (e.g. vibration, etc.), it is not the intent of the IDSS IDD to mandate all of these requirements; these requirements must be addressed as part of the specific developer's unique program, spacecraft and mission needs. This approach allows designers the flexibility to design and build docking mechanisms to their unique program needs and requirements. The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions.The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions. The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions.
Jiang, Zhehan; Skorupski, William
2017-12-12
In many behavioral research areas, multivariate generalizability theory (mG theory) has been typically used to investigate the reliability of certain multidimensional assessments. However, traditional mG-theory estimation-namely, using frequentist approaches-has limits, leading researchers to fail to take full advantage of the information that mG theory can offer regarding the reliability of measurements. Alternatively, Bayesian methods provide more information than frequentist approaches can offer. This article presents instructional guidelines on how to implement mG-theory analyses in a Bayesian framework; in particular, BUGS code is presented to fit commonly seen designs from mG theory, including single-facet designs, two-facet crossed designs, and two-facet nested designs. In addition to concrete examples that are closely related to the selected designs and the corresponding BUGS code, a simulated dataset is provided to demonstrate the utility and advantages of the Bayesian approach. This article is intended to serve as a tutorial reference for applied researchers and methodologists conducting mG-theory studies.
EPOS--The European E-Portfolio of Languages
ERIC Educational Resources Information Center
Kühn, Bärbel
2016-01-01
Democratic principles and human rights, the core values of the Council of Europe, informed the development of the "Common European Framework of Reference for Languages" (CEFR; Council of Europe 2001. "Common European framework of reference for languages: Learning, teaching, assessment." Cambridge: Cambridge University Press.…
Common source cascode amplifiers for integrating IR-FPA applications
NASA Technical Reports Server (NTRS)
Woolaway, James T.; Young, Erick T.
1989-01-01
Space based astronomical infrared measurements present stringent performance requirements on the infrared detector arrays and their associated readout circuitry. To evaluate the usefulness of commercial CMOS technology for astronomical readout applications a theoretical and experimental evaluation was performed on source follower and common-source cascode integrating amplifiers. Theoretical analysis indicates that for conditions where the input amplifier integration capacitance is limited by the detectors capacitance the input referred rms noise electrons of each amplifier should be equivalent. For conditions of input gate limited capacitance the source follower should provide lower noise. Measurements of test circuits containing both source follower and common source cascode circuits showed substantially lower input referred noise for the common-source cascode input circuits. Noise measurements yielded 4.8 input referred rms noise electrons for an 8.5 minute integration. The signal and noise gain of the common-source cascode amplifier appears to offer substantial advantages in acheiving predicted noise levels.
Beliefs about chlamydia testing amongst young people living in relatively deprived areas.
Booth, A R; Harris, P R; Goyder, E; Norman, P
2013-06-01
This study uses the theory of planned behaviour (TPB) as a framework to investigate salient beliefs about chlamydia testing, amongst young people living in relatively deprived areas. These beliefs may form targets for intervention to increase testing in this high-risk population. Participants recruited from colleges in deprived areas of a UK city, completed open-ended questions designed to elicit salient beliefs. Responses were content analysed and categorized as describing behavioural, normative or control beliefs. Beliefs were elicited from 128 respondents (51% male; median age = 17). The commonest behavioural belief, which could have a positive or negative impact on screening intentions, was that testing provides information about health status. Partners were referred to most commonly amongst the normative beliefs. Practical aspects and concerns about social implications of testing were common control beliefs. References to several negative emotions emerged throughout. This study indicates that raising awareness of chlamydia as a serious sexual health problem may not be the best way to increase the uptake of testing in a high-risk population. Promoting chlamydia testing as potentially providing reassurance may be an alternative. It may also be important to reduce perceptions of social disapproval as well as negative emotion regarding chlamydia testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brotz, Jay Kristoffer; Hymel, Ross W; Punnoose, Ratish J.
One of the greatest challenges facing designers of equipment to be used in a nuclear arms control treaty is how to convince the other party in the treaty to trust its results and functionality. Whether the host provides equipment meant to prove treaty obligations and the inspector needs to gain that trust (commonly referred to as authentication), or the inspector provides this equipment and the host needs to gain this trust (commonly considered to be included in certification), one party generally has higher confidence in the equipment at the start of a treaty regime and the other party needs tomore » gain that confidence prior to use. While we focus on authentication in this document—that is, the inspector gaining confidence in host-provided equipment—our conclusions will likely apply to host certification of inspector-provided equipment.« less
A biopolymer-like metal enabled hybrid material with exceptional mechanical prowess
Zhang, Junsong; Cui, Lishan; Jiang, Daqiang; ...
2015-02-10
In this study, the design principles for naturally occurring biological materials have inspired us to develop next-generation engineering materials with remarkable performance. Nacre, commonly referred to as nature's armor, is renowned for its unusual combination of strength and toughness. Nature's wisdom in nacre resides in its elaborate structural design and the judicious placement of a unique organic biopolymer with intelligent deformation features. However, up to now, it is still a challenge to transcribe the biopolymer's deformation attributes into a stronger substitute in the design of new materials. In this study, we propose a new design strategy that employs shape memorymore » alloy to transcribe the "J-curve'' mechanical response and uniform molecular/atomic level deformation of the organic biopolymer in the design of high-performance hybrid materials. This design strategy is verified in a TiNi-Ti 3Sn model material system. The model material demonstrates an exceptional combination of mechanical properties that are superior to other high-performance metal-based lamellar composites known to date. Our design strategy creates new opportunities for the development of high-performance bio-inspired materials.« less
A biopolymer-like metal enabled hybrid material with exceptional mechanical prowess
Zhang, Junsong; Cui, Lishan; Jiang, Daqiang; Liu, Yinong; Hao, Shijie; Ren, Yang; Han, Xiaodong; Liu, Zhenyang; Wang, Yunzhi; Yu, Cun; Huan, Yong; Zhao, Xinqing; Zheng, Yanjun; Xu, Huibin; Ren, Xiaobing; Li, Xiaodong
2015-01-01
The design principles for naturally occurring biological materials have inspired us to develop next-generation engineering materials with remarkable performance. Nacre, commonly referred to as nature's armor, is renowned for its unusual combination of strength and toughness. Nature's wisdom in nacre resides in its elaborate structural design and the judicious placement of a unique organic biopolymer with intelligent deformation features. However, up to now, it is still a challenge to transcribe the biopolymer's deformation attributes into a stronger substitute in the design of new materials. In this study, we propose a new design strategy that employs shape memory alloy to transcribe the “J-curve” mechanical response and uniform molecular/atomic level deformation of the organic biopolymer in the design of high-performance hybrid materials. This design strategy is verified in a TiNi-Ti3Sn model material system. The model material demonstrates an exceptional combination of mechanical properties that are superior to other high-performance metal-based lamellar composites known to date. Our design strategy creates new opportunities for the development of high-performance bio-inspired materials. PMID:25665501
A biopolymer-like metal enabled hybrid material with exceptional mechanical prowess.
Zhang, Junsong; Cui, Lishan; Jiang, Daqiang; Liu, Yinong; Hao, Shijie; Ren, Yang; Han, Xiaodong; Liu, Zhenyang; Wang, Yunzhi; Yu, Cun; Huan, Yong; Zhao, Xinqing; Zheng, Yanjun; Xu, Huibin; Ren, Xiaobing; Li, Xiaodong
2015-02-10
The design principles for naturally occurring biological materials have inspired us to develop next-generation engineering materials with remarkable performance. Nacre, commonly referred to as nature's armor, is renowned for its unusual combination of strength and toughness. Nature's wisdom in nacre resides in its elaborate structural design and the judicious placement of a unique organic biopolymer with intelligent deformation features. However, up to now, it is still a challenge to transcribe the biopolymer's deformation attributes into a stronger substitute in the design of new materials. In this study, we propose a new design strategy that employs shape memory alloy to transcribe the "J-curve" mechanical response and uniform molecular/atomic level deformation of the organic biopolymer in the design of high-performance hybrid materials. This design strategy is verified in a TiNi-Ti3Sn model material system. The model material demonstrates an exceptional combination of mechanical properties that are superior to other high-performance metal-based lamellar composites known to date. Our design strategy creates new opportunities for the development of high-performance bio-inspired materials.
Ceriotti, Ferruccio
2017-07-01
Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
A novel technique for reference point generation to aid in intraoral scan alignment.
Renne, Walter G; Evans, Zachary P; Mennito, Anthony; Ludlow, Mark
2017-11-12
When using a completely digital workflow on larger prosthetic cases it is often difficult to communicate to the laboratory or chairside Computer Aided Design and Computer Aided Manufacturing system the provisional prosthetic information. The problem arises when common hard tissue data points are limited or non-existent such as in complete arch cases in which the 3D model of the complete arch provisional restorations must be aligned perfectly with the 3D model of the complete arch preparations. In these instances, soft tissue is not enough to ensure an accurate automatic or manual alignment due to a lack of well-defined reference points. A new technique is proposed for the proper digital alignment of the 3D virtual model of the provisional prosthetic to the 3D virtual model of the prepared teeth in cases where common and coincident hard tissue data points are limited. Clinical considerations: A technique is described in which fiducial composite resin dots are temporarily placed on the intraoral keratinized tissue in strategic locations prior to final impressions. These fiducial dots provide coincident and clear 3D data points that when scanned into a digital impression allow superimposition of the 3D models. Composite resin dots on keratinized tissue were successful at allowing accurate merging of provisional restoration and post-preparation 3D models for the purpose of using the provisional restorations as a guide for final CLINICAL SIGNIFICANCE: Composite resin dots placed temporarily on attached tissue were successful at allowing accurate merging of the provisional restoration 3D models to the preparation 3D models for the purposes of using the provisional restorations as a guide for final restoration design and manufacturing. In this case, they allowed precise superimposition of the 3D models made in the absence of any other hard tissue reference points, resulting in the fabrication of ideal final restorations. © 2017 Wiley Periodicals, Inc.
Asynchronous reference frame agreement in a quantum network
NASA Astrophysics Data System (ADS)
Islam, Tanvirul; Wehner, Stephanie
2016-03-01
An efficient implementation of many multiparty protocols for quantum networks requires that all the nodes in the network share a common reference frame. Establishing such a reference frame from scratch is especially challenging in an asynchronous network where network links might have arbitrary delays and the nodes do not share synchronised clocks. In this work, we study the problem of establishing a common reference frame in an asynchronous network of n nodes of which at most t are affected by arbitrary unknown error, and the identities of the faulty nodes are not known. We present a protocol that allows all the correctly functioning nodes to agree on a common reference frame as long as the network graph is complete and not more than t\\lt n/4 nodes are faulty. As the protocol is asynchronous, it can be used with some assumptions to synchronise clocks over a network. Also, the protocol has the appealing property that it allows any existing two-node asynchronous protocol for reference frame agreement to be lifted to a robust protocol for an asynchronous quantum network.
Alcohol Brand Appearances in U.S. Popular Music
Primack, Brian A.; Nuzzo, Erin; Rice, Kristen R.; Sargent, James D.
2011-01-01
Aims The average US adolescent is exposed to 34 references to alcohol in popular music daily. Although brand recognition is an independent, potent risk factor for alcohol outcomes among adolescents, alcohol brand appearances in popular music have not been systematically assessed. We aimed to determine the prevalence of and contextual elements associated with alcohol brand appearances in U.S. popular music. Design Qualitative content analysis. Setting We used Billboard Magazine to identify songs to which US adolescents were most exposed in 2005-2007. For each of the 793 songs, two trained coders independently analyzed the lyrics of each song for references to alcohol and alcohol brand appearances. Subsequent in-depth assessments utilised Atlas.ti to determine contextual factors associated with each of the alcohol brand appearances. Measurements Our final code book contained 27 relevant codes representing 6 categories: alcohol types, consequences, emotional states, activities, status, and objects. Findings Average inter-rater reliability was high (κ=0.80), and all differences were easily adjudicated. Of the 793 songs in our sample, 169 (21.3%) explicitly referred to alcohol, and of those, 41 (24.3%) contained an alcohol brand appearance. Consequences associated with alcohol were more often positive than negative (41.5% vs. 17.1%, P<.001). Alcohol brand appearances were commonly associated with wealth (63.4%), sex (58.5%), luxury objects (51.2%), partying (48.8%), other drugs (43.9%), and vehicles (39.0%). Conclusions One-in-five songs sampled from U.S. popular music had explicit references to alcohol, and one quarter of these mentioned a specific alcohol brand. These alcohol brand appearances are commonly associated with a luxury lifestyle characterised by wealth, sex, partying, and other drugs. PMID:22011113
Nguyen, Douglas L; Rasheed, Sarah; Parekh, Nimisha K
2014-05-01
To define the patterns of Internet use among physicians who treat inflammatory bowel disease (IBD) and physicians' perceptions of their patients' Internet use. An online survey about physician and patient use of the Internet was created and e-mailed to gastroenterologists nationwide. Surveys were distributed and collected via an online database and a subsequent statistical analysis was performed. Of the 1000 e-mail invitations sent to practicing gastroenterologists in the United States, 223 participants (22.3%) completed the survey. A total of 183 (82.1%) physicians reported using an Internet-based reference to assist them in deriving management strategies for their patients with IBD, with the most commonly utilized resource being UpToDate followed by PubMed and the Crohn's and Colitis Foundation of America Web site. Although nearly 80% of gastroenterologists believed that using the Internet helped them facilitate clinical discussions, 183 participants (82.1%) believed that inaccurate information found online could sometimes result in increased clinic time because physicians must spend more time dispelling misleading information. Despite a study design biased toward selecting gastroenterologists who commonly used the Internet, we demonstrated that only 60% of the providers routinely refer their patients to the Internet. This underscores the fact that it is important to have a centralized "physician-certified" online resource to which physicians could readily refer their patients to navigate through various disease-specific resources without concern that their patients are receiving unreliable or misleading information.
75 FR 70850 - Common Crop Insurance Regulations; Extra Long Staple Cotton Crop Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... Crop Insurance Regulations; Extra Long Staple Cotton Crop Provisions AGENCY: Federal Crop Insurance... Corporation (FCIC) proposes to amend the Common Crop Insurance Regulations, Extra Long Staple Cotton Crop Insurance Provisions to remove all references to the Daily Spot Cotton Quotation and replace the reference...
Degrading and non-degrading sex in popular music: a content analysis.
Primack, Brian A; Gold, Melanie A; Schwarz, Eleanor B; Dalton, Madeline A
2008-01-01
Those exposed to more degrading sexual references in popular music are more likely to initiate intercourse at a younger age. The purpose of this study was to perform a content analysis of contemporary popular music with particular attention paid to the prevalence of degrading and non-degrading sexual references. We also aimed to determine if sexual references of each subtype were associated with other song characteristics and/or content. We used Billboard magazine to identify the top popular songs in 2005. Two independent coders each analyzed all of these songs (n = 279) for degrading and non-degrading sexual references. As measured with Cohen's kappa scores, inter-rater agreement on degrading vs. non-degrading sex was substantial. Mentions of substance use, violence, and weapon carrying were also coded. Of the 279 songs identified, 103 (36.9%) contained references to sexual activity. Songs with references to degrading sex were more common than songs with references to non-degrading sex (67 [65.0%] vs. 36 [35.0%], p < 0.001). Songs with degrading sex were most commonly Rap (64.2%), whereas songs with non-degrading sex were most likely Country (44.5%) or Rhythm & Blues/Hip-Hop (27.8%). Compared with songs that had no mention of sexual activity, songs with degrading sex were more likely to contain references to substance use, violence, and weapon carrying. Songs with non-degrading sex were no more likely to mention these other risk behaviors. References to sexual activity are common in popular music, and degrading sexual references are more prevalent than non-degrading references. References to degrading sex also frequently appear with references to other risky behaviors.
Antidiabetic effects of Momordica charantia (bitter melon) and its medicinal potency
Joseph, Baby; Jini, D
2013-01-01
Diabetes mellitus is among the most common disorder in developed and developing countries, and the disease is increasing rapidly in most parts of the world. It has been estimated that up to one-third of patients with diabetes mellitus use some form of complementary and alternative medicine. One plant that has received the most attention for its anti-diabetic properties is bitter melon, Momordica charantia (M. charantia), commonly referred to as bitter gourd, karela and balsam pear. Its fruit is also used for the treatment of diabetes and related conditions amongst the indigenous populations of Asia, South America, India and East Africa. Abundant pre-clinical studies have documented in the anti-diabetic and hypoglycaemic effects of M. charantia through various postulated mechanisms. However, clinical trial data with human subjects are limited and flawed by poor study design and low statistical power. The present review is an attempt to highlight the antidiabetic activity as well as phytochemical and pharmacological reports on M. charantia and calls for better-designed clinical trials to further elucidate its possible therapeutic effects on diabetes.
Hein, Sascha; Zangl, Michael
2016-01-01
The aim of this in vitro study was to investigate the color changes of human teeth caused by five different diffuser materials commonly used in dental photography, as well as software influence, and to confirm whether the use of a standardized gray reference card is effective in correcting these color changes during digital postproduction. Forty extracted human teeth were obtained from a specialized oral surgery practice in Cham, Germany. Five commonly used diffuser materials were chosen to be investigated, which included: polyethylene (PET), White Frost photographic paper, LumiQuest polyamide (nylon) material, 80 gsm white printing paper, and 3M linear polarizing filter sheet used for cross polarization. A digital single-lens reflex camera (Canon EOS 5D MKII) was used, together with a twin flash suitable for macrophotography (Canon MT-24EX Macro Twin Lite). Images were tethered into Adobe Lightroom CC using the RAW format. A standardized gray reference card (WhiBal, Michael Tapes Design) was used for exposure calibration and white balancing. Classic Color Me- ter software (Ricci Adams, version 1.6 (122)) was used to obtain CIE L*a*b* values of the specimens before and after white balancing and exposure correction. All diffusers caused visually perceivable color changes on the extracted teeth: White Frost (ΔE* 1.24; sd 0.47), 80 gsm printing paper (ΔE* 2.94; sd 0.35), LumiQuest polyamide (ΔE* 3.68; sd 0.54), PET (ΔE* 6.55; sd 0.41), and 3M linear polarizing filter sheet (ΔE* 7.58; sd 1.00). The use of a standardized gray reference card (WhiBal) could correct these values below the visually perceivable threshold: White Frost (ΔE* 0.58; sd 0.36), 80 gsm printing paper (ΔE* 0.93; sd 0.54), LumiQuest polyamide (ΔE* 0.66; sd 0.58), PET (ΔE* 0.59; sd 0.33), and 3M linear polarizing filter sheet (ΔE* 0.53; sd 0.42). The use of a standardized gray reference card with specified CIE L*a*b* values should be considered when diffusers are used in dental photography in order to reveal the color of preoperative situations (ie, shade documentation) and document postoperative results accurately.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Curtis; Rabiti, Cristian; Martineau, Richard
Safety is central to the design, licensing, operation, and economics of Nuclear Power Plants (NPPs). As the current Light Water Reactor (LWR) NPPs age beyond 60 years, there are possibilities for increased frequency of Systems, Structures, and Components (SSCs) degradations or failures that initiate safety-significant events, reduce existing accident mitigation capabilities, or create new failure modes. Plant designers commonly “over-design” portions of NPPs and provide robustness in the form of redundant and diverse engineered safety features to ensure that, even in the case of well-beyond design basis scenarios, public health and safety will be protected with a very high degreemore » of assurance. This form of defense-in-depth is a reasoned response to uncertainties and is often referred to generically as “safety margin.” Historically, specific safety margin provisions have been formulated, primarily based on “engineering judgment.”« less
Bossé, Janine T; Li, Yanwen; Sárközi, Rita; Gottschalk, Marcelo; Angen, Øystein; Nedbalcova, Katerina; Rycroft, Andrew N; Fodor, László; Langford, Paul R
2017-03-01
Actinobacillus pleuropneumoniae causes pleuropneumonia, an economically significant lung disease of pigs. Recently, isolates of A. pleuropneumoniae that were serologically distinct from the previously characterized 15 serovars were described, and a proposal was put forward that they comprised a new serovar, serovar 16. Here we used whole-genome sequencing of the proposed serovar 16 reference strain A-85/14 to confirm the presence of a unique capsular polysaccharide biosynthetic locus. For molecular diagnostics, primers were designed from the capsule locus of strain A-85/14, and a PCR was formulated that differentiated serovar 16 isolates from all 15 known serovars and other common respiratory pathogenic/commensal bacteria of pigs. Analysis of the capsule locus of strain A-85/14 combined with the previous serological data show the existence of a sixteenth serovar-designated serovar 16-of A. pleuropneumoniae . Copyright © 2017 Bossé et al.
Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin
2014-01-01
Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block. PMID:25258742
Flexible Educational Facilities. An Annotated Reference List.
ERIC Educational Resources Information Center
Wakefield, Howard E.
These references on flexible educational facilities are abstracted by the ERIC Clearinghouse on Educational Facilities. College material includes an experimental learning center, a college health center, a fine arts center, and university library design. References on schools include secondary school design, flexible high school design, standard…
ERIC Educational Resources Information Center
Barenfanger, Olaf; Tschirner, Erwin
2008-01-01
The major goal of the Council of Europe to promote and facilitate communication and interaction among Europeans of different mother tongues has led to the development of the "Common European Framework of Reference for Languages: Learning, Teaching, Assessment" (CEFR). Among other things, the CEFR is intended to help language…
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
15 CFR 200.104 - Standard reference materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...
Seven Pervasive Statistical Flaws in Cognitive Training Interventions
Moreau, David; Kirk, Ian J.; Waldie, Karen E.
2016-01-01
The prospect of enhancing cognition is undoubtedly among the most exciting research questions currently bridging psychology, neuroscience, and evidence-based medicine. Yet, convincing claims in this line of work stem from designs that are prone to several shortcomings, thus threatening the credibility of training-induced cognitive enhancement. Here, we present seven pervasive statistical flaws in intervention designs: (i) lack of power; (ii) sampling error; (iii) continuous variable splits; (iv) erroneous interpretations of correlated gain scores; (v) single transfer assessments; (vi) multiple comparisons; and (vii) publication bias. Each flaw is illustrated with a Monte Carlo simulation to present its underlying mechanisms, gauge its magnitude, and discuss potential remedies. Although not restricted to training studies, these flaws are typically exacerbated in such designs, due to ubiquitous practices in data collection or data analysis. The article reviews these practices, so as to avoid common pitfalls when designing or analyzing an intervention. More generally, it is also intended as a reference for anyone interested in evaluating claims of cognitive enhancement. PMID:27148010
Niu, Ben; Li, Lu
2018-06-01
This brief proposes a new neural-network (NN)-based adaptive output tracking control scheme for a class of disturbed multiple-input multiple-output uncertain nonlinear switched systems with input delays. By combining the universal approximation ability of radial basis function NNs and adaptive backstepping recursive design with an improved multiple Lyapunov function (MLF) scheme, a novel adaptive neural output tracking controller design method is presented for the switched system. The feature of the developed design is that different coordinate transformations are adopted to overcome the conservativeness caused by adopting a common coordinate transformation for all subsystems. It is shown that all the variables of the resulting closed-loop system are semiglobally uniformly ultimately bounded under a class of switching signals in the presence of MLF and that the system output can follow the desired reference signal. To demonstrate the practicability of the obtained result, an adaptive neural output tracking controller is designed for a mass-spring-damper system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marchisio, Mario Andrea, E-mail: marchisio@hit.edu.cn
Published in 2008, Parts & Pools represents one of the first attempts to conceptualize the modular design of bacterial synthetic gene circuits with Standard Biological Parts (DNA segments) and Pools of molecules referred to as common signal carriers (e.g., RNA polymerases and ribosomes). The original framework for modeling bacterial components and designing prokaryotic circuits evolved over the last years and brought, first, to the development of an algorithm for the automatic design of Boolean gene circuits. This is a remarkable achievement since gene digital circuits have a broad range of applications that goes from biosensors for health and environment caremore » to computational devices. More recently, Parts & Pools was enabled to give a proper formal description of eukaryotic biological circuit components. This was possible by employing a rule-based modeling approach, a technique that permits a faithful calculation of all the species and reactions involved in complex systems such as eukaryotic cells and compartments. In this way, Parts & Pools is currently suitable for the visual and modular design of synthetic gene circuits in yeast and mammalian cells too.« less
Howie, Bryan N.; Donnelly, Peter; Marchini, Jonathan
2009-01-01
Genotype imputation methods are now being widely used in the analysis of genome-wide association studies. Most imputation analyses to date have used the HapMap as a reference dataset, but new reference panels (such as controls genotyped on multiple SNP chips and densely typed samples from the 1,000 Genomes Project) will soon allow a broader range of SNPs to be imputed with higher accuracy, thereby increasing power. We describe a genotype imputation method (IMPUTE version 2) that is designed to address the challenges presented by these new datasets. The main innovation of our approach is a flexible modelling framework that increases accuracy and combines information across multiple reference panels while remaining computationally feasible. We find that IMPUTE v2 attains higher accuracy than other methods when the HapMap provides the sole reference panel, but that the size of the panel constrains the improvements that can be made. We also find that imputation accuracy can be greatly enhanced by expanding the reference panel to contain thousands of chromosomes and that IMPUTE v2 outperforms other methods in this setting at both rare and common SNPs, with overall error rates that are 15%–20% lower than those of the closest competing method. One particularly challenging aspect of next-generation association studies is to integrate information across multiple reference panels genotyped on different sets of SNPs; we show that our approach to this problem has practical advantages over other suggested solutions. PMID:19543373
von Luhmann, Alexander; Wabnitz, Heidrun; Sander, Tilmann; Muller, Klaus-Robert
2017-06-01
For the further development of the fields of telemedicine, neurotechnology, and brain-computer interfaces, advances in hybrid multimodal signal acquisition and processing technology are invaluable. Currently, there are no commonly available hybrid devices combining bioelectrical and biooptical neurophysiological measurements [here electroencephalography (EEG) and functional near-infrared spectroscopy (NIRS)]. Our objective was to design such an instrument in a miniaturized, customizable, and wireless form. We present here the design and evaluation of a mobile, modular, multimodal biosignal acquisition architecture (M3BA) based on a high-performance analog front-end optimized for biopotential acquisition, a microcontroller, and our openNIRS technology. The designed M3BA modules are very small configurable high-precision and low-noise modules (EEG input referred noise @ 500 SPS 1.39 μV pp , NIRS noise equivalent power NEP 750 nm = 5.92 pW pp , and NEP 850 nm = 4.77 pW pp ) with full input linearity, Bluetooth, 3-D accelerometer, and low power consumption. They support flexible user-specified biopotential reference setups and wireless body area/sensor network scenarios. Performance characterization and in-vivo experiments confirmed functionality and quality of the designed architecture. Telemedicine and assistive neurotechnology scenarios will increasingly include wearable multimodal sensors in the future. The M3BA architecture can significantly facilitate future designs for research in these and other fields that rely on customized mobile hybrid biosignal modal biosignal acquisition architecture (M3BA), multimodal, near-infrared spectroscopy (NIRS), wireless body area network (WBAN), wireless body sensor network (WBSN).
Sinkala, Fatima; Parsons, Richard; Sunderland, Bruce; Hoti, Kreshnik
2018-01-01
Background Antibiotic misuse in the community contributes to antimicrobial resistance. One way to address this may be by better utilizing community pharmacists’ skills in antibiotic prescribing. The aims of this study were to examine the level of support for “down-scheduling” selected antibiotics and to evaluate factors determining the appropriateness of community pharmacist prescribing for a limited range of infections, including their decision to refer to a doctor. Methods Self-administered questionnaires, including graded case vignette scenarios simulating real practice, were sent to Western Australian community pharmacists. In addition to descriptive statistics and chi-square testing, a General Estimating Equation (GEE) was used to identify factors associated with appropriateness of therapy and the decision to refer, for each of the seven vignettes. Results Of the 240 pharmacists surveyed, 90 (37.5%) responded, yielding 630 responses to seven different case vignettes. There was more than 60% respondent support for expanded prescribing (rescheduling) of commonly prescribed antibiotics. Overall 426/630 (67.6%) chose to treat the patient while the remaining 204/630 (32.4%) referred the patient to a doctor. Of those electing to treat, 380/426 (89.2%) opted to use oral antibiotics, with 293/380 (77.2%) treating with an appropriate selection and regimen. The GEE model indicated that pharmacists were more likely to prescribe inappropriately for conditions such as otitis media (p = 0.0060) and urinary tract infection in pregnancy (p < 0.0001) compared to more complex conditions. Over 80% of all pharmacists would refer the patient to a doctor following no improvement within 3 days, or within 24 h in the case of community acquired pneumonia. It was more common for younger pharmacists to refer the patient to a doctor (p = 0.0165). Discussion This study adds further insight into community pharmacy/pharmacist characteristics associated with appropriateness of oral antibiotic selection and the decision to refer to doctors. These findings require consideration in designing pharmacist over-the-counter prescribing models for oral antibiotics. PMID:29761047
Sinkala, Fatima; Parsons, Richard; Sunderland, Bruce; Hoti, Kreshnik; Czarniak, Petra
2018-01-01
Antibiotic misuse in the community contributes to antimicrobial resistance. One way to address this may be by better utilizing community pharmacists' skills in antibiotic prescribing. The aims of this study were to examine the level of support for "down-scheduling" selected antibiotics and to evaluate factors determining the appropriateness of community pharmacist prescribing for a limited range of infections, including their decision to refer to a doctor. Self-administered questionnaires, including graded case vignette scenarios simulating real practice, were sent to Western Australian community pharmacists. In addition to descriptive statistics and chi-square testing, a General Estimating Equation (GEE) was used to identify factors associated with appropriateness of therapy and the decision to refer, for each of the seven vignettes. Of the 240 pharmacists surveyed, 90 (37.5%) responded, yielding 630 responses to seven different case vignettes. There was more than 60% respondent support for expanded prescribing (rescheduling) of commonly prescribed antibiotics. Overall 426/630 (67.6%) chose to treat the patient while the remaining 204/630 (32.4%) referred the patient to a doctor. Of those electing to treat, 380/426 (89.2%) opted to use oral antibiotics, with 293/380 (77.2%) treating with an appropriate selection and regimen. The GEE model indicated that pharmacists were more likely to prescribe inappropriately for conditions such as otitis media ( p = 0.0060) and urinary tract infection in pregnancy ( p < 0.0001) compared to more complex conditions. Over 80% of all pharmacists would refer the patient to a doctor following no improvement within 3 days, or within 24 h in the case of community acquired pneumonia. It was more common for younger pharmacists to refer the patient to a doctor ( p = 0.0165). This study adds further insight into community pharmacy/pharmacist characteristics associated with appropriateness of oral antibiotic selection and the decision to refer to doctors. These findings require consideration in designing pharmacist over-the-counter prescribing models for oral antibiotics.
Aronson, Jeffrey K
2016-01-01
Objective To examine how misspellings of drug names could impede searches for published literature. Design Database review. Data source PubMed. Review methods The study included 30 drug names that are commonly misspelt on prescription charts in hospitals in Birmingham, UK (test set), and 30 control names randomly chosen from a hospital formulary (control set). The following definitions were used: standard names—the international non-proprietary names, variant names—deviations in spelling from standard names that are not themselves standard names in English language nomenclature, and hidden reference variants—variant spellings that identified publications in textword (tw) searches of PubMed or other databases, and which were not identified by textword searches for the standard names. Variant names were generated from standard names by applying letter substitutions, omissions, additions, transpositions, duplications, deduplications, and combinations of these. Searches were carried out in PubMed (30 June 2016) for “standard name[tw]” and “variant name[tw] NOT standard name[tw].” Results The 30 standard names of drugs in the test set gave 325 979 hits in total, and 160 hidden reference variants gave 3872 hits (1.17%). The standard names of the control set gave 470 064 hits, and 79 hidden reference variants gave 766 hits (0.16%). Letter substitutions (particularly i to y and vice versa) and omissions together accounted for 2924 (74%) of the variants. Amitriptyline (8530 hits) yielded 18 hidden reference variants (179 (2.1%) hits). Names ending in “in,” “ine,” or “micin” were commonly misspelt. Failing to search for hidden reference variants of “gentamicin,” “amitriptyline,” “mirtazapine,” and “trazodone” would miss at least 19 systematic reviews. A hidden reference variant related to Christmas, “No-el”, was rare; variants of “X-miss” were rarer. Conclusion When performing searches, researchers should include misspellings of drug names among their search terms. PMID:27974346
Mental health epidemiological research in South America: recent findings
Silva de Lima, Maurício; Garcia de Oliveira Soares, Bernardo; de Jesus Mari, Jair
2004-01-01
This paper aims to review the recent mental health epidemiological research conducted in South America. The Latin American and the Caribbean (LILACS) database was searched from 1999 to 2003 using a specific strategy for identification of cohort, case-control and cross-sectional population-based studies in South America. The authors screened references and identified relevant studies. Further studies were obtained contacting local experts in epidemiology. 140 references were identified, and 12 studies were selected. Most selected studies explored the prevalence and risk factors for common mental disorders, and several of them used sophisticated methods of sample selection and analysis. There is a need for improving the quality of psychiatric journals in Latin America, and for increasing the distribution and access to research data. Regionally relevant problems such as violence and substance abuse should be considered in designing future investigations in this area. PMID:16633474
Levelized Cost of Energy Analysis of Marine and Hydrokinetic Reference Models: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenne, D. S.; Yu, Y. H.; Neary, V.
2015-04-24
In 2010 the U.S. Department of Energy initiated the development of six marine energy converter reference models. The reference models are point designs of well-known marine energy converters. Each device was designed to operate in a specific marine resource, instead of a generic device that can be deployed at any location. This method allows each device to be used as a benchmark for future reference model to benchmark future devices. The six designs consist of three current energy converters and three wave energy converters. The reference model project has generated both technical and economic data sets that are available inmore » the public domain. The methodology to calculate the levelized cost of energy for the reference model project and an overall comparison of the cost of energy from these six reference-model designs are presented in this paper.« less
Hennekinne, Jacques-Antoine; Gohier, Martine; Maire, Tiphaine; Lapeyre, Christiane; Lombard, Bertrand; Dragacci, Sylviane
2003-01-01
The European Commission has designed a network of European Union-National Reference Laboratories (EU-NRLs), coordinated by a Community Reference Laboratory (CRL), for control of hygiene of milk and milk products (Council Directive 92/46/ECC). As a common contaminant of milk and milk products such as cheese, staphylococcal enterotoxins are often involved in human outbreaks and should be monitored regularly. The main tasks of the EU-CRLs were to select and transfer to the EU-NRLs a reference method for detection of enterotoxins, and to set up proficiency testing to evaluate the competency of the European laboratory network. The first interlaboratory exercise was performed on samples of freeze-dried cheese inoculated with 2 levels of staphylococcal enterotoxins (0.1 and 0.25 ng/g) and on an uninoculated control. These levels were chosen considering the EU regulation for staphylococcal enterotoxins in milk and milk products and the limit of detection of the enzyme-linked immunosorbent assay test recommended in the reference method. The trial was conducted according to the recommendations of ISO Guide 43. Results produced by laboratories were compiled and compared through statistical analysis. Except for data from 2 laboratories for the uninoculated control and cheese inoculated at 0.1 ng/g, all laboratories produced satisfactory results, showing the ability of the EU-NRL network to monitor the enterotoxin contaminant.
Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph
2007-01-01
The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.
Measures of outdoor play and independent mobility in children and youth: A methodological review.
Bates, Bree; Stone, Michelle R
2015-09-01
Declines in children's outdoor play have been documented globally, which are partly due to heightened restrictions around children's independent mobility. Literature on outdoor play and children's independent mobility is increasing, yet no paper has summarized the various methodological approaches used. A methodological review could highlight most commonly used measures and comprehensive research designs that could result in more standardized methodological approaches. Methodological review. A standardized protocol guided a methodological review of published research on measures of outdoor play and children's independent mobility in children and youth (0-18 years). Online searches of 8 electronic databases were conducted and studies included if they contained a subjective/objective measure of outdoor play or children's independent mobility. References of included articles were scanned to identify additional articles. Twenty-four studies were included on outdoor play, and twenty-three on children's independent mobility. Study designs were diverse. Common objective measures included accelerometry, global positioning systems and direct observation; questionnaires, surveys and interviews were common subjective measures. Focus groups, activity logs, monitoring sheets, travel/activity diaries, behavioral maps and guided tours were also utilized. Questionnaires were used most frequently, yet few studies used the same questionnaire. Five studies employed comprehensive, mixed-methods designs. Outdoor play and children's independent mobility have been measured using a wide variety of techniques, with only a few studies using similar methodologies. A standardized methodological approach does not exist. Future researchers should consider including both objective measures (accelerometry and global positioning systems) and subjective measures (questionnaires, activity logs, interviews), as more comprehensive designs will enhance understanding of each multidimensional construct. Creating a standardized methodological approach would improve study comparisons. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
MIL-HDBK-338-Environmental Conversion Table Correction
NASA Technical Reports Server (NTRS)
Hark, Frank; Novack, Steve
2017-01-01
In reliability analysis for space launch vehicles, limited data is frequently a challenge due to the pure number of launches. A common solution is to use surrogate historical data of similar components from other industries (military data). The operating environment of the common data may be different from that of the necessary target analysis. The military electronic design handbook (MIL-HDBK-338) has a table for converting Mean Time Between Failure (MTBF) data from one environment to another. However, the table has some discrepancies and rounding of complementary conversions; namely going from environment A to B does not given the same result as going from B to A. This presentation will show the discrepancies in the original conversation table, the greater than expected magnitude, the problem with the updated published table and a suggested corrected table to reference when doing MTBF data environment conversion.
Goals and Strategies for the Human Lunar Reference Architecture
NASA Technical Reports Server (NTRS)
Seaman, Calvin H.
2010-01-01
The presentation examines common goals for human lunar exploration and strategic guidance. Three major sections include illustrative example goals, introduction to the GPoD campaign, and GPoD overview. The first section includes slides about strategic view of partnerships, the moon as a stepping stone and a uniquely preserved record, human-robotic partnership, innovative engagement, strategic considerations, and evaluation of campaigns against common goals. The second section examines campaigns considered, the philosophy of GPoD, GPoD campaign phase definitions, and GPoD design decision points. The third section examines lunar exploration capabilities, extended stay-relocation exploration mode, notional campaign destinations for GPoD, early robotics phase, development of the GPoD early robotics phase, polar exploration/system validation phase, polar relocatability phase, non-polar relocatability phase, long duration phase, and return to evaluation of campaigns.
Task-level control for autonomous robots
NASA Technical Reports Server (NTRS)
Simmons, Reid
1994-01-01
Task-level control refers to the integration and coordination of planning, perception, and real-time control to achieve given high-level goals. Autonomous mobile robots need task-level control to effectively achieve complex tasks in uncertain, dynamic environments. This paper describes the Task Control Architecture (TCA), an implemented system that provides commonly needed constructs for task-level control. Facilities provided by TCA include distributed communication, task decomposition and sequencing, resource management, monitoring and exception handling. TCA supports a design methodology in which robot systems are developed incrementally, starting first with deliberative plans that work in nominal situations, and then layering them with reactive behaviors that monitor plan execution and handle exceptions. To further support this approach, design and analysis tools are under development to provide ways of graphically viewing the system and validating its behavior.
Witchcraft illness in the Evuzok nosological system.
Guimera, L M
1978-12-01
The Evuzok nosological system is structured with respect to two frames of reference, one designating illness as an empirical reality (descriptive subsystem), the other designating it according to its religious, magical and social significance (etiological subsystem). The articulation of these two subsystems is brought about in the process of diagnosis. Having examined this system as a whole, the author devotes his attention to a particular set of etiological categories, those which associate illness with witchcraft (nocturnal illnesses). He attempts to define their distinctive traits and, from this, to determine their common elemental structure. This study, based on a number of years of fieldwork, is part of an ongoing research program on African folk-medicine pursued by the Laboratoire d'Ethnologie et de Sociologie Comparative of the Université de Paris X.
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
2015-01-01
This paper presents an overview of the sixth revision to an algorithm specifically designed to support NASA's Airborne Precision Spacing concept. This algorithm is referred to as the Airborne Spacing for Terminal Arrival Routes version 13 (ASTAR13). This airborne self-spacing concept contains both trajectory-based and state-based mechanisms for calculating the speeds required to achieve or maintain a precise spacing interval. The trajectory-based capability allows for spacing operations prior to the aircraft being on a common path. This algorithm was also designed specifically to support a standalone, non-integrated implementation in the spacing aircraft. This current revision to the algorithm adds the state-based capability in support of evolving industry standards relating to airborne self-spacing.
A frequency-sensing readout using piezoelectric sensors for sensing of physiological signals.
Buxi, Dilpreet; Redouté, Jean-Michel; Yuce, Mehmet Rasit
2014-01-01
Together with a charge or voltage amplifier, piezoelectric sensors are commonly used to pick up physiological vibrations from the body. As an alternative to chopper or auto-zero amplifiers, frequency sensing is known in literature to provide advantages of noise immunity, interfacing to digital readout systems as well as tunable range of sensing. A frequency-sensing readout circuit for sensing low voltage signals from piezoelectric sensors is successfully developed and tested in this work. The output voltage of a piezoelectric sensor is fed to a varactor, which is part of an Colpitts LC oscillator. The oscillation frequency is converted into a voltage using a phase locked loop. The circuit is compared to a reference design in terms of linearity, noise and transfer function. The readout has a input-referred noise voltage of 2.24μV/√Hz and consumes 15 mA at 5V supply. Arterial pulse wave signals and the cardiac vibrations from the chest are measured from one subject to show the proof of concept of the proposed readout. The results of this work are intended to contribute towards alternative low noise analog front end designs for piezoelectric sensors.
Synthetic Proxy Infrastructure for Task Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Junghans, Christoph; Pavel, Robert
The Synthetic Proxy Infrastructure for Task Evaluation is a proxy application designed to support application developers in gauging the performance of various task granularities when determining how best to utilize task based programming models.The infrastructure is designed to provide examples of common communication patterns with a synthetic workload intended to provide performance data to evaluate programming model and platform overheads for the purpose of determining task granularity for task decomposition purposes. This is presented as a reference implementation of a proxy application with run-time configurable input and output task dependencies ranging from an embarrassingly parallel scenario to patterns with stencil-likemore » dependencies upon their nearest neighbors. Once all, if any, inputs are satisfied each task will execute a synthetic workload (a simple DGEMM of in this case) of varying size and output all, if any, outputs to the next tasks.The intent is for this reference implementation to be implemented as a proxy app in different programming models so as to provide the same infrastructure and to allow for application developers to simulate their own communication needs to assist in task decomposition under various models on a given platform.« less
Endless forms: human behavioural diversity and evolved universals.
Smith, Eric Alden
2011-02-12
Human populations have extraordinary capabilities for generating behavioural diversity without corresponding genetic diversity or change. These capabilities and their consequences can be grouped into three categories: strategic (or cognitive), ecological and cultural-evolutionary. Strategic aspects include: (i) a propensity to employ complex conditional strategies, some certainly genetically evolved but others owing to directed invention or to cultural evolution; (ii) situations in which fitness payoffs (or utilities) are frequency-dependent, so that there is no one best strategy; and (iii) the prevalence of multiple equilibria, with history or minor variations in starting conditions (path dependence) playing a crucial role. Ecological aspects refer to the fact that social behaviour and cultural institutions evolve in diverse niches, producing various adaptive radiations and local adaptations. Although environmental change can drive behavioural change, in humans, it is common for behavioural change (especially technological innovation) to drive environmental change (i.e. niche construction). Evolutionary aspects refer to the fact that human capacities for innovation and cultural transmission lead to diversification and cumulative cultural evolution; critical here is institutional design, in which relatively small shifts in incentive structure can produce very different aggregate outcomes. In effect, institutional design can reshape strategic games, bringing us full circle.
Multiplex PCR method to discriminate Artemisia iwayomogi from other Artemisia plants.
Doh, Eui Jeong; Oh, Seung-Eun
2012-01-01
Some plants in the genus Artemisia have been used for medicinal purposes. Among them, Artemisia iwayomogi, commonly referred to as "Haninjin," is one of the major medicinal materials used in traditional Korean medicine. By contrast, Artemisia capillaris and both Artemisia argyi and Artemisia princeps, referred to as "Injinho" and "Aeyup," respectively, are used to treat diseases different from those for which "Haninjin" is prescribed. Therefore, the development of a reliable method to differentiate each Artemisia herb is necessary. We found that a random amplified polymorphic DNA (RAPD) method can be used to efficiently discriminate a few Artemisia plants from one another. To improve the reliability of RAPD amplification, we designed primer sets based on the nucleotide sequences of RAPD products to amplify a sequence-characterized amplified region (SCAR) marker of A. iwayomogi. In addition, we designed two other primer sets to amplify SCAR markers of "Aeyup" (A. argyi and A. princeps) along with "Injinho" (A. capillaris) and Artemisia japonica, which are also traded in Korean herbal markets. Using these three primer sets, we developed a multiplex PCR method concurrently not only to discriminate A. iwayomogi from other Artemisia plants, but also to identify Artemisia plants using a single PCR process.
The positive side of a negative reference: the delay between linguistic processing and common ground
Noveck, Ira; Rivera, Natalia; Jaume-Guazzini, Francisco
2017-01-01
Interlocutors converge on names to refer to entities. For example, a speaker might refer to a novel looking object as the jellyfish and, once identified, the listener will too. The hypothesized mechanism behind such referential precedents is a subject of debate. The common ground view claims that listeners register the object as well as the identity of the speaker who coined the label. The linguistic view claims that, once established, precedents are treated by listeners like any other linguistic unit, i.e. without needing to keep track of the speaker. To test predictions from each account, we used visual-world eyetracking, which allows observations in real time, during a standard referential communication task. Participants had to select objects based on instructions from two speakers. In the critical condition, listeners sought an object with a negative reference such as not the jellyfish. We aimed to determine the extent to which listeners rely on the linguistic input, common ground or both. We found that initial interpretations were based on linguistic processing only and that common ground considerations do emerge but only after 1000 ms. Our findings support the idea that—at least temporally—linguistic processing can be isolated from common ground. PMID:28386440
NASA Astrophysics Data System (ADS)
Zhang, Yonggao; Gao, Yanli; Long, Lizhong
2012-04-01
More and more researchers have great concern on the issue of Common-mode voltage (CMV) in high voltage large power converter. A novel common-mode voltage suppression scheme based on zero-vector PWM strategy (ZVPWM) is present in this paper. Taking a diode-clamped five-level converter as example, the principle of zero vector PWM common-mode voltage (ZCMVPWM) suppression method is studied in detail. ZCMVPWM suppression strategy is including four important parts, which are locating the sector of reference voltage vector, locating the small triangular sub-sector of reference voltage vector, reference vector synthesis, and calculating the operating time of vector. The principles of four important pars are illustrated in detail and the corresponding MATLAB models are established. System simulation and experimental results are provided. It gives some consultation value for the development and research of multi-level converters.
Reference and Information Services: An Introduction. Second Edition. Library Science Text Series.
ERIC Educational Resources Information Center
Bopp, Richard E., Ed.; Smith, Linda C., Ed.
This document provides an overview of the concepts and processes behind reference services and the most important sources consulted in answering common reference questions. The book is divided into two parts. Part 1 deals with concepts and theory. It covers ethical aspects of reference service, the reference interview, the principles and goals of…
Roberts, Jane H; Bernard, Paul M
2012-06-01
Background General practitioners (GPs) play a key role in assessing and managing adult mental health problems, but this input is not seen in their management of child and adolescent mental health. Mental health problems in 5-19-year-olds are common, yet detection rates in primary care are low. The symptoms of most adult diagnoses of mental health problems are present by mid-adolescence, yet the typical time from onset to diagnosis is 5-15 years. The role of general practice in this area has been underexplored. Aim This pilot study explores the potential of GPs to respond to common mental health problems in children and adolescents. Design Children and young people who would have ordinarily been referred to Child and Adolescent Mental Health Services (CAMHS) were seen in a GP setting. In a UK general practice surgery serving a disadvantaged population. Method Children and young people were seen for an initial biopsychosocial assessment and formulation of the presenting concerns. GP-based interventions were offered as appropriate or referred to CAMHS. Results Data from the first 50 children (2-19 years) are presented. Twenty younger children (10 years and under) and 30 older children (11 years and above) were seen. Eighteen referrals were made to CAMHS. GP interventions included watchful waiting, brief behavioural interventions, non-directive counselling, brief cognitive- behavioural therapy (CBT) and liaison with colleagues in education, CAMHS and the voluntary sector. Conclusion This clinical pilot demonstrates that with adequate time, access to supervision and practice support, children and young people experiencing emotional and behavioural problems associated with common mental health issues can be helped in primary care.
Design and Performance Improvement of AC Machines Sharing a Common Stator
NASA Astrophysics Data System (ADS)
Guo, Lusu
With the increasing demand on electric motors in various industrial applications, especially electric powered vehicles (electric cars, more electric aircrafts and future electric ships and submarines), both synchronous reluctance machines (SynRMs) and interior permanent magnet (IPM) machines are recognized as good candidates for high performance variable speed applications. Developing a single stator design which can be used for both SynRM and IPM motors is a good way to reduce manufacturing and maintenance cost. SynRM can be used as a low cost solution for many electric driving applications and IPM machines can be used in power density crucial circumstances or work as generators to meet the increasing demand for electrical power on board. In this research, SynRM and IPM machines are designed sharing a common stator structure. The prototype motors are designed with the aid of finite element analysis (FEA). Machine performances with different stator slot and rotor pole numbers are compared by FEA. An 18-slot, 4-pole structure is selected based on the comparison for this prototype design. Sometimes, torque pulsation is the major drawback of permanent magnet synchronous machines. There are several sources of torque pulsations, such as back-EMF distortion, inductance variation and cogging torque due to presence of permanent magnets. To reduce torque pulsations in permanent magnet machines, all the efforts can be classified into two categories: one is from the design stage, the structure of permanent magnet machines can be optimized with the aid of finite element analysis. The other category of reducing torque pulsation is after the permanent magnet machine has been manufactured or the machine structure cannot be changed because of other reasons. The currents fed into the permanent magnet machine can be controlled to follow a certain profile which will make the machine generate a smoother torque waveform. Torque pulsation reduction methods in both categories will be discussed in this dissertation. In the design stage, an optimization method based on orthogonal experimental design will be introduced. Besides, a universal current profiling technique is proposed to minimize the torque pulsation along with the stator copper losses in modular interior permanent magnet motors. Instead of sinusoidal current waveforms, this algorithm will calculate the proper currents which can minimize the torque pulsation. Finite element analysis and Matlab programing will be used to develop this optimal current profiling algorithm. Permanent magnet machines are becoming more attractive in some modern traction applications, such as traction motors and generators for an electrified vehicle. The operating speed or the load condition in these applications may be changing all the time. Compared to electric machines used to operate at a constant speed and constant load, better control performance is required. In this dissertation, a novel model reference adaptive control (MRAC) used on five-phase interior permanent magnet motor drives is presented. The primary controller is designed based on artificial neural network (ANN) to simulate the nonlinear characteristics of the system without knowledge of accurate motor model or parameters. The proposed motor drive decouples the torque and flux components of five-phase IPM motors by applying a multiple reference frame transformation. Therefore, the motor can be easily driven below the rated speed with the maximum torque per ampere (MTPA) operation or above the rated speed with the flux weakening operation. The ANN based primary controller consists of a radial basis function (RBF) network which is trained on-line to adapt system uncertainties. The complete IPM motor drive is simulated in Matlab/Simulink environment and implemented experimentally utilizing dSPACE DS1104 DSP board on a five-phase prototype IPM motor. The proposed model reference adaptive control method has been applied on the commons stator SynRM and IPM machine as well.
An experimental investigation of ejector performance based upon different refrigerants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, S.L.; Yen, J.Y.; Huang, M.C.
1998-12-31
This article experimentally compares the characteristics of different refrigerants as the working fluid in an ejector cooling system. The study covers common refrigerants including R-113, R-114, R-142b, and R-718. The critical choking conditions against the variation of condenser back pressure, the evaporator pressure, and the generator pressure are determined for each refrigerant. The results are compiled into a convenient performance curve and COP chart. These results can serve as an important reference for future design of ejector cooling systems. Finally, this paper presents a comparison of the performances of different refrigerants in an ejector cooling system.
NASA Technical Reports Server (NTRS)
Lutzky, D.; Bjorkman, W. S.
1973-01-01
The Mission Analysis Evaluation and Space Trajectory Operations program known as MAESTRO is described. MAESTRO is an all FORTRAN, block style, computer program designed to perform various mission control tasks. This manual is a guide to MAESTRO, providing individuals the capability of modifying the program to suit their needs. Descriptions are presented of each of the subroutines descriptions consist of input/output description, theory, subroutine description, and a flow chart where applicable. The programmer's manual also contains a detailed description of the common blocks, a subroutine cross reference map, and a general description of the program structure.
The Common European Framework of Reference (CEFR) in Canada: A Research Agenda
ERIC Educational Resources Information Center
Arnott, Stephanie; Brogden, Lace Marie; Faez, Farahnaz; Péguret, Muriel; Piccardo, Enrica; Rehner, Katherine; Taylor, Shelley K.; Wernicke, Meike
2017-01-01
This article proposes a research agenda for future inquiry into the use of the Common European Framework of Reference (CEFR) in the plurilingual Canadian context. Drawing on data collected from a research forum hosted by the Canadian Association of Second Language Teachers in 2014, as well as a detailed analysis of Canadian empirical studies and…
NASA Astrophysics Data System (ADS)
Schulz-von der Gathen, Volker
2015-09-01
Over the last decade a huge variety of atmospheric pressure plasma jets has been developed and applied for plasma medicine. The efficiency of these non-equilibrium plasmas for biological application is based on the generated amounts of reactive species and radiation. The gas temperatures stay within a range tolerable for temperature-sensitive tissues. The variety of different discharge geometries complicates a direct comparison. In addition, in plasma-medicine the combination of plasma with reactive components, ambient air, as well as biologic tissue - typically also incorporating fluids - results in a complex system. Thus, real progress in plasma-medicine requires a profound knowledge of species, their fluxes and processes hitting biological tissues. That will allow in particular the necessary tailoring of the discharge to fit the conditions. The complexity of the problem can only be overcome by a common effort of many groups and requires a comparison of their results. A reference device based on the already well-investigated micro-scaled atmospheric pressure plasma jet is presented. It is developed in the frame of the European COST initiative MP1101 to establish a publicly available, stable and reproducible source, where required plasma conditions can be investigated. Here we present the design and the ideas behind. The presentation discusses the requirements for the reference source and operation conditions. Biological references are also defined by the initiative. A specific part of the talk will be attributed to the reproducibility of results from various samples of the device. Funding by the DFG within the Package Project PAK816 ``Plasma Cell Interaction in Dermatology'' and the Research Unit FOR 1123 ``Physics of microplasmas'' is gratefully acknowledged.
Connecting kinematic and dynamic reference frames by D-VLBI
NASA Astrophysics Data System (ADS)
Schuh, Harald; Plank, Lucia; Madzak, Matthias; Böhm, Johannes
2012-08-01
In geodetic and astrometric practice, terrestrial station coordinates are usually provided in the kinematic International Terrestrial Reference Frame (ITRF) and radio source coordinates in the International Celestial Reference Frame (ICRF), whereas measurements of space probes such as satellites and spacecrafts, or planetary ephemerides rest upon dynamical theories. To avoid inconsistencies and errors during measurement and calculation procedures, exact frame ties between quasi - inertial, kinematic and dynamic reference frames have to be secured. While the Earth Orientation Parameters (EOP), e.g. measured by VLBI, link the ITRF to the ICRF, the ties with the dynamic frames can be established with the differential Very Long Baseline Interferometry (D - VLBI) method. By observing space probes alternately t o radio sources, the relative position of the targets to each other on the sky can be determined with high accuracy. While D - VLBI is a common technique in astrophysics (source imaging) and deep space navigation, just recently there have been several effort s to use it for geodetic purposes. We present investigations concerning possible VLBI observations to satellites. This includes the potential usage of available GNNS satellites as well as specifically designed missions, as e.g. the GRASP mission proposed b y JPL/NASA and an international consortium, where the aspect of co - location in space of various techniques (VLBI, SLR, GNSS, DORIS) is the main focus.
Gautam, S; Kapur, R L; Shamasundar, C
1980-07-01
60 General practitioners having M.B., B.S. qualification from all age group practicing in Bangalore city's centrally located locality were personally visited and a specially designed proforma was administered to find out whether they come across Psychiatric patients in their general practice, if yes what percentage of their practice ? Whether they referred any cases for Psychiatric consultation, what factors determined their decision to refer a case to the psychiatrist.9% General practitioners reportedly were seeing Psychiatric cases, on an average 10% of total patients seen by GP's were suffering from Psychiatric illness. 85% GP's had referred cases for Psychiatric consultation and factors which determined GP's decision to refer a case were : Request from patient to see a Specialist, patient was excited and unmanageable, pressure from relatives of patients serious impirsonment of patients' working capacity, patient finds it more acceptable to be told by a Specialist that he has nervous trouble, lack of emotional support from family of patient. Less commonly given reasons inlcuded inability to diagnose a case, for confirmation of diagnosis and treatment, for detailed examination and investigation, for better managment, resistant casses and lack of time to deal with Psychiatric problems. These findings have been discussed and their implications in planning further services have been highlighted.
Gautam, Shiv; Kapur, R. L.; Shamasundar, C.
1980-01-01
SUMMARY 60 General practitioners having M.B., B.S. qualification from all age group practicing in Bangalore city's centrally located locality were personally visited and a specially designed proforma was administered to find out whether they come across Psychiatric patients in their general practice, if yes what percentage of their practice ? Whether they referred any cases for Psychiatric consultation, what factors determined their decision to refer a case to the psychiatrist. 9% General practitioners reportedly were seeing Psychiatric cases, on an average 10% of total patients seen by GP's were suffering from Psychiatric illness. 85% GP's had referred cases for Psychiatric consultation and factors which determined GP's decision to refer a case were : Request from patient to see a Specialist, patient was excited and unmanageable, pressure from relatives of patients serious impirsonment of patients' working capacity, patient finds it more acceptable to be told by a Specialist that he has nervous trouble, lack of emotional support from family of patient. Less commonly given reasons inlcuded inability to diagnose a case, for confirmation of diagnosis and treatment, for detailed examination and investigation, for better managment, resistant casses and lack of time to deal with Psychiatric problems. These findings have been discussed and their implications in planning further services have been highlighted. PMID:22058484
Ng, Annie W Y; Siu, Kin Wai Michael; Chan, Chetwyn C H
2012-01-01
This study investigated the influence of user factors and symbol referents on public symbol design among older people, using the stereotype production method for collecting user ideas during the symbol design process. Thirty-one older adults were asked to draw images based on 28 public symbol referents and to indicate their familiarity with and ease with which they visualised each referent. Differences were found between the pictorial solutions generated by males and females. However, symbol design was not influenced by participants' education level, vividness of visual imagery, object imagery preference or spatial imagery preference. Both familiar and unfamiliar referents were illustrated pictorially without much difficulty by users. The more visual the referent, the less difficulty the users had in illustrating it. The findings of this study should aid the optimisation of the stereotype production method for user-involved symbol design. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Method of pedestal and common-mode noise correction for switched-capacitor analog memories
Britton, Charles L.
1997-01-01
A method and apparatus for correcting common-mode noise and pedestal noise in a multichannel array of switched-capacitor analog memories wherein each analog memory is connected to an associated analog-to-digital converter. The apparatus comprises a single differential element in two different embodiments. In a first embodiment, the differential element is a reference analog memory connected to a buffer. In the second embodiment, the differential dement is a reference analog memory connected to a reference analog-to-digital connected to an array of digital summing circuits.
Method of pedestal and common-mode noise correction for switched-capacitor analog memories
Britton, Charles L.
1996-01-01
A method and apparatus for correcting common-mode noise and pedestal noise in a multichannel array of switched-capacitor analog memories wherein each analog memory is connected to an associated analog-to-digital converter. The apparatus comprises a single differential element in two different embodiments. In a first embodiment, the differential element is a reference analog memory connected to a buffer. In the second embodiment, the differential element is a reference analog memory connected to a reference analog-to-digital connected to an array of digital summing circuits.
Civil engineering reference guide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merritt, F.S.
1986-01-01
The civil engineering reference guide contains the following: Structural theory. Structural steel design. Concrete design and construction. Wood design and construction. Bridge engineering. Geotechnical engineering. Water engineering. Environmental engineering. Surveying.
Engaging teenagers productively in service design.
Bowen, Simon; Sustar, Helena; Wolstenholme, Daniel; Dearden, Andy
2013-09-01
Engaging young people in participatory design can be challenging, particularly in health-related projects. In a study co-designing diabetes support and information services with teenagers, we found framing activities using popular culture was a useful strategy. Various cultural references helped us stage activities that were productive for the design process, and were engaging for our young participants (e.g. exploring practical implications through discussions in a 'Dragons' Den'). Some activities were more effective than others and the idea of language-games , which has been widely explored in participatory design, explains why our strategy was successful when there was a clear 'family resemblance' between the popular cultural references and certain essential stages of designing. However, attention is required in selecting appropriate cultural references if this strategy is adopted elsewhere, and design facilitators should focus first on devising accessible language-games, rather than expecting popular cultural references to provide complete solutions to the challenge of staging participatory design.
Mariot, Roberta Fogliatto; de Oliveira, Luisa Abruzzi; Voorhuijzen, Marleen M; Staats, Martijn; Hutten, Ronald C B; Van Dijk, Jeroen P; Kok, Esther; Frazzon, Jeverson
2015-01-01
Potato (Solanum tuberosum) yield has increased dramatically over the last 50 years and this has been achieved by a combination of improved agronomy and biotechnology efforts. Gene studies are taking place to improve new qualities and develop new cultivars. Reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) is a bench-marking analytical tool for gene expression analysis, but its accuracy is highly dependent on a reliable normalization strategy of an invariant reference genes. For this reason, the goal of this work was to select and validate reference genes for transcriptional analysis of edible tubers of potato. To do so, RT-qPCR primers were designed for ten genes with relatively stable expression in potato tubers as observed in RNA-Seq experiments. Primers were designed across exon boundaries to avoid genomic DNA contamination. Differences were observed in the ranking of candidate genes identified by geNorm, NormFinder and BestKeeper algorithms. The ranks determined by geNorm and NormFinder were very similar and for all samples the most stable candidates were C2, exocyst complex component sec3 (SEC3) and ATCUL3/ATCUL3A/CUL3/CUL3A (CUL3A). According to BestKeeper, the importin alpha and ubiquitin-associated/ts-n genes were the most stable. Three genes were selected as reference genes for potato edible tubers in RT-qPCR studies. The first one, called C2, was selected in common by NormFinder and geNorm, the second one is SEC3, selected by NormFinder, and the third one is CUL3A, selected by geNorm. Appropriate reference genes identified in this work will help to improve the accuracy of gene expression quantification analyses by taking into account differences that may be observed in RNA quality or reverse transcription efficiency across the samples.
Jump, Robin L. P.; Olds, Danielle M.; Jury, Lucy A.; Sitzlar, Brett; Saade, Elie; Watts, Brook; Bonomo, Robert A.; Donskey, Curtis J.
2013-01-01
Background Residents of long-term care facilities (LTCFs) are a population vulnerable to infections and to the adverse effects of inappropriate antimicrobial prescribing. To improve the care of residents with possible infections, we initiated a LTCF Infectious Disease (LID) service that provides on-site consultations to LTCF residents. Design Clinical demonstration project Setting A 160-bed LTCF affiliated with a tertiary care Veterans Affairs (VA) hospital. Participants Residents referred to the LID Team. Measurements The reason for and source of LTCF residents’ referral to the LID team as well as their demographics, infectious disease diagnoses, interventions and hospitalizations were determined. Results Between July 2009 and December 2010, the LID consult service provided 291 consults for 250 LTCF residents. Referrals came from either the LTCF staff (75%) or the VA hospital’s ID consult service (25%). The most common diagnoses were Clostridium difficile infection (14%), asymptomatic bacteriuria (10%), and urinary tract infection (10%). More than half of referred patients were on antibiotic therapy when first seen by the LID team; 46% of patients required an intervention. The most common interventions, stopping (32%) or starting (26%) antibiotics, were made in accordance with principles of antibiotic stewardship. Conclusion The LID team represents a novel and effective means to bring subspecialty care to LTCF residents. PMID:23590125
Du, Wen-Juan; Ji, Jun; Wang, Ling; Lan, Xin-Yi; Li, Jia; Lei, Jun-Qiu; He, Xin; Zhang, Chun-Feng; Huang, Wen-Zhe; Wang, Zhen-Zhong; Xiao, Wei; Wang, Chong-Zhi; Yuan, Chun-Su
2017-12-01
Daphne genkwa Sieb.et Zucc. is a well-known medicinal plant. This study was designed to apply the ultra-high performance liquid chromatography system to establish a quality control method for D. genkwa. Data revealed that there were 15 common peaks in 10 batches of D. genkwa Sieb. Et Zucc. (Thymelaeaceae) from different provinces of China. On this basis, the fingerprint chromatogram was established to provide references for quality control. Afterwards, the chemical constitutions of these common peaks were analyzed using the UPLC-Q-TOF-MS system and nine of them were identified. In addition, LPS-stimulated RAW264.7 murine macrophages and DPPH assay were used to study the anti-inflammatory and anti-oxidation effects of D. genkwa. Then the fingerprint-efficacy relationships between UPLC fingerprints and pharmacodynamic data were studied with canonical correlation analysis. Analysis results indicated that the anti-inflammatory and anti-oxidation effects differed among the 10 D. genkwa samples owing to their inherent differences of chemical compositions. Taken together, this research established a fingerprint-efficacy relationship model of D. genkwa plant by combining the UPLC analytic technique and pharmacological research, which provided references for the detection of the principal components of traditional Chinese medicine on bioactivity. Copyright © 2017 John Wiley & Sons, Ltd.
Open access gastroscopy: too much to swallow?
Kerrigan, D D; Brown, S R; Hutchinson, G H
1990-01-01
OBJECTIVES--To ascertain the proportion of endoscopic examinations with normal findings in patients referred for gastroscopy through hospital medical staff or directly by their general practitioner and to assess the likely effect of targeting endoscopy in older patients. DESIGN--Retrospective audit of the gastroscopy practice of one consultant from 1986 to 1988 from information recorded on a standard form completed at the time of the examination, which contained details of patients, their endoscopic findings, and mode of referral (open access or clinic). SETTING--One district general hospital. PATIENTS--1545 Consecutive patients from primary catchment area attending for their first gastroscopy; 454 were referred through the outpatient clinic or by hospital colleagues (clinic group) and 1091 were accepted for endoscopy solely on their general practitioner's clinical diagnosis (open access group). RESULTS--Similar numbers (about 40%) of examinations with normal findings were performed in each group, although in patients aged over 40 the proportion with normal findings was significantly higher in the clinic group (p less than 0.03). Endoscopic evidence of gastro-oesophageal reflux disease, peptic ulceration, and gastroduodenal inflammation was equally common in each group; upper gastrointestinal malignancy, however, was significantly more common in patients referred through hospital doctors (5%, 23/454 v 2%, 22/1091 respectively; p less than 0.005) (although many of these patients had already been extensively investigated). IMPLICATIONS--Open access gastroscopy does not increase the number of unnecessary examinations and should become more widely available. Targeting this service to patients aged over 40 would reduce the number of requests but increase the diagnostic yield. PMID:2106992
10 CFR 50.150 - Aircraft impact assessment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...
10 CFR 50.150 - Aircraft impact assessment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...
10 CFR 50.150 - Aircraft impact assessment.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...
10 CFR 50.150 - Aircraft impact assessment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 13, 2009; (B) Renewal of standard design certifications in effect on July 13, 2009 which have not..., standard design approval, or manufactured reactor; or (B) Reference a standard design certification issued... certification or standard design approval; or (B) Reference a standard design certification issued before July...
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
THOR Fluxgate Magnetometer (MAG)
NASA Astrophysics Data System (ADS)
Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Carr, Christopher, M.; O'Brien, Helen, L.; Narita, Yasuhito; K, Chen, Christopher H.; Berghofer, Gerhard; Valavanoglou, Aris; Delva, Magda; Plaschke, Ferdinand; Cupido, Emanuele; Soucek, Jan
2017-04-01
Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The fluxgate Magnetometer (MAG) measures the background to low frequency magnetic field. The high sensitivity measurements of MAG enable to characterize the nature of turbulent fluctuations as well as the large-scale context. MAG will provide the reference system for determining anisotropy of field fluctuations, pitch-angle and gyro-phase of particles. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two- sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy. We discuss the role of MAG in THOR key science questions and present the new developments during Phase A such as the finalised instrument design, MAG relevant requirement, and new calibraion schemes.
ERIC Educational Resources Information Center
Kubinger, Klaus D.; Litzenberger, Margarete; Mrakotsky, Christine
2006-01-01
The question is to what extent intelligence test-batteries prove any kind of empirical reference to common intelligence theories. Of particular interest are conceptualized tests that are of a high psychometric standard--those that fit the Rasch model--and hence are not exposed to fundamental critique. As individualized testing, i.e., a…
Common lines modeling for reference free Ab-initio reconstruction in cryo-EM.
Greenberg, Ido; Shkolnisky, Yoel
2017-11-01
We consider the problem of estimating an unbiased and reference-free ab initio model for non-symmetric molecules from images generated by single-particle cryo-electron microscopy. The proposed algorithm finds the globally optimal assignment of orientations that simultaneously respects all common lines between all images. The contribution of each common line to the estimated orientations is weighted according to a statistical model for common lines' detection errors. The key property of the proposed algorithm is that it finds the global optimum for the orientations given the common lines. In particular, any local optima in the common lines energy landscape do not affect the proposed algorithm. As a result, it is applicable to thousands of images at once, very robust to noise, completely reference free, and not biased towards any initial model. A byproduct of the algorithm is a set of measures that allow to asses the reliability of the obtained ab initio model. We demonstrate the algorithm using class averages from two experimental data sets, resulting in ab initio models with resolutions of 20Å or better, even from class averages consisting of as few as three raw images per class. Copyright © 2017 Elsevier Inc. All rights reserved.
Personal digital assistant applications for the healthcare provider.
Keplar, Kristine E; Urbanski, Christopher J
2003-02-01
To review some common medical applications available for personal digital assistants (PDAs), with brief discussion of the different PDA operating systems and memory requirements. Key search terms included handheld, PDA, personal digital assistants, and medical applications. The literature was accessed through MEDLINE (1999-August 2002). Other information was obtained through secondary sources such as Web sites describing common PDAs. Medical applications available on PDAs are numerous and include general drug references, specialized drug references (e.g., pediatrics, geriatrics, cardiology, infectious disease), diagnostic guides, medical calculators, herbal medication references, nursing references, toxicology references, and patient tracking databases. Costs and memory requirements for these programs can vary; consequently, the healthcare provider must limit the medication applications that are placed on the handheld computer. This article attempts to systematically describe the common medical applications available for the handheld computer along with cost, memory and download requirements, and Web site information. This review found many excellent PDA drug information applications offering many features which will aid the healthcare provider. Very likely, after using these PDA applications, the healthcare provider will find them indispensable, as their multifunctional capabilities can save time, improve accuracy, and allow for general business procedures as well as being a quick reference tool. To avoid the benefits of this technology might be a step backward.
Prevalence of spinal disorders and their relationships with age and gender
Alshami, Ali M.
2015-01-01
Objectives: To establish the period prevalence of spinal disorders referred to physical therapy in a university hospital over a 3-year period, and to determine the relationships of common spinal disorders with patients’ age and gender. Methods: This retrospective study was conducted in the Physical Therapy Department, King Fahd Hospital of the University, Dammam, Saudi Arabia. Computer data of all new electronic referrals from January 2011 to December 2013 were retrieved and reviewed. The computer data included demographic information, referring facility, and diagnosis/disorder. Results: One thousand six hundred and sixty-nine (28.1%) of all referred patients (5929) had spinal disorders. The most common disorders affected the lumbar spine (53.1%) and cervical spine (27.1%), and pain was the most common disorder. Neck pain (60.5%) was more common in patients <30 years old (p<0.001). Cervical spondylosis was common (~30%) in the >30 age groups. Spondylosis and low back pain were more prevalent in women (7.8% and 76.2%) than in men (73.9% and 3.3%). Conclusion: Spinal disorders were common compared with other disorders. Low back pain and neck pain were the most common spinal disorders. Age and gender were weakly related to some of the disorders that affected the lumbar and cervical spine. PMID:25987116
Design and Principles Enabling the Space Reference FOM
NASA Technical Reports Server (NTRS)
Moeller, Bjoern; Dexter, Dan; Madden, Michael; Crues, Edwin Z.; Garro, Alfredo; Skuratovskiy, Anton
2017-01-01
A first complete draft of the Simulation Interoperability Standards Organization (SISO) Space Reference Federation Object Model (FOM) has now been produced. This paper provides some insights into its capabilities and discusses the opportunity for reuse in other domains. The focus of this first version of the standard is execution control, time management and coordinate systems, well-known reference frames, as well as some basic support for physical entities. The biggest part of the execution control is the coordinated start-up process. This process contains a number of steps, including checking of required federates, handling of early versus late joiners, sharing of federation wide configuration data and multi-phase initialization. An additional part of Execution Control is the coordinated and synchronized transition between Run mode, Freeze mode and Shutdown. For time management, several time lines are defined, including real-time, scenario time, High Level Architecture (HLA) logical time and physical time. A strategy for mixing simulations that use different time steps is introduced, as well as an approach for finding common boundaries for fully synchronized freeze. For describing spatial information, a mechanism with a set of reference frames is specified. Each reference frame has a position and orientation related to a parent reference frame. This makes it possible for federates to perform calculations in reference frames that are convenient to them. An operation on the Moon can be performed using lunar coordinates whereas an operation on Earth can be performed using Earth coordinates. At the same time, coordinates in one reference frame have an unambiguous relationship to a coordinate in another reference frame. While the Space Reference FOM is originally being developed for Space operations, the authors believe that many parts of it can be reused for any simulation that has a focus on physical processes with one or more coordinate systems, and require high fidelity and repeatability.
Symptoms of Common Mental Disorders in Professional Football (Soccer) Across Five European Countries
Gouttebarge, Vincent; Backx, Frank J.G.; Aoki, Haruhito; Kerkhoffs, Gino M.M.J.
2015-01-01
Evidence on the prevalence of symptoms related to distress, anxiety/depression or substance abuse/dependence, – typically referred to as symptoms of common mental disorders (CMD) – is lacking in European professional football (soccer). The aims of the present study were to investigate the prevalence of symptoms related to CMD (distress, anxiety/depression, sleeping disturbance, adverse alcohol behaviour, and adverse nutrition behaviour) in professional footballers from five European countries, and to explore associations of the outcome measures under study with life events and career dissatisfaction. A cross-sectional design was used. Questionnaires were distributed among professional footballers by the national players’ unions in Finland, France, Norway, Spain and Sweden. The highest prevalence of symptoms related to common mental disorders were 18% for distress (Sweden), 43% for anxiety/depression (Norway), 33% for sleeping disturbance (Spain), 17% for adverse alcohol behaviour (Finland), and 74% for adverse nutrition behaviour (Norway). In Finland, France and Sweden, both life events and career dissatisfaction were associated with distress, anxiety/depression, adverse alcohol behaviour, and adverse nutrition behaviour. Results suggest the need for self-awareness in professional football about common mental disorders and a multidisciplinary approach by the medical team. Key points The highest prevalence of symptoms related to common mental disorders were 18% for distress (Sweden), 43% for anxiety/depression (Norway), 33% for sleeping disturbance (Spain), 17% for adverse alcohol behaviour (Finland), and 74% for adverse nutrition behaviour (Norway). In Finland, France and Sweden, both life events and career dissatisfaction were associated with distress, anxiety/depression, adverse alcohol behaviour, and adverse nutrition behaviour. Our results suggest the need for self-awareness in professional football about common mental disorders and a multidisciplinary approach by the medical team. Further research based on longitudinal design should be conducted in order to acquire an insight into the causal relationship between symptoms related to common mental disorders and risk factors. PMID:26664278
Jaw Intraosseous Lesions Biopsied Extracted From 1998 to 2010 in an Iranian Population
Jamshidi, Shokoofeh; Shojaei, Setareh; Roshanaei, Ghodratollah; Modabbernia, Shirin; Bakhtiary, Esmaeel
2015-01-01
Background: Jaw bones might be potential locations for different lesions. Differences in prevalence and the type of lesions can help in designing and programming prevention procedures in health care centers. Objectives: The aim of the present study was to evaluate the prevalence of intraosseous lesions in the jaws of patients referred to diagnostic and therapeutic centers in Hamadan during 1990-2010. Patients and Methods: This cross-sectional descriptive analytical study was carried out in Hamadan in 2011. Data sheets of the subjects were used to collect all the data of patients with intraosseous lesions, including their age, gender, location of the lesion, the radiographic view of lesions, and their type and histopathological diagnoses. Data were analyzed with SPSS, using means and frequencies. Results: A total of 284 intraosseous lesions were reported in our study. The mean age of the subjects was 28.8 ± 15.2 years. The lesions were distributed in males and females almost similarly. The most prevalent lesions were cystic lesions (54.58%), manifestations of systemic conditions in jaw bones (18.3%), benign tumors (15.5%), malignant lesions (6.7%), and inflammatory lesions (4.92%), in a descending order. The most common cystic lesion was radicular cyst; the most common manifestation of systemic conditions in jaw bones was central giant cell granuloma; the most common benign tumor was ameloblastoma; the most common malignant lesion was osteosarcoma; and the most common inflammatory lesion was periapical granuloma. Conclusions: Our data provided information on the prevalence and types of intraosseous lesions among an Iranian population. This study provided baseline information to help in designing and programming procedures in health care centers in every community so that preventive therapeutic measures can be adopted. PMID:26328061
Sevy, Alexander M.; Jacobs, Tim M.; Crowe, James E.; Meiler, Jens
2015-01-01
Computational protein design has found great success in engineering proteins for thermodynamic stability, binding specificity, or enzymatic activity in a ‘single state’ design (SSD) paradigm. Multi-specificity design (MSD), on the other hand, involves considering the stability of multiple protein states simultaneously. We have developed a novel MSD algorithm, which we refer to as REstrained CONvergence in multi-specificity design (RECON). The algorithm allows each state to adopt its own sequence throughout the design process rather than enforcing a single sequence on all states. Convergence to a single sequence is encouraged through an incrementally increasing convergence restraint for corresponding positions. Compared to MSD algorithms that enforce (constrain) an identical sequence on all states the energy landscape is simplified, which accelerates the search drastically. As a result, RECON can readily be used in simulations with a flexible protein backbone. We have benchmarked RECON on two design tasks. First, we designed antibodies derived from a common germline gene against their diverse targets to assess recovery of the germline, polyspecific sequence. Second, we design “promiscuous”, polyspecific proteins against all binding partners and measure recovery of the native sequence. We show that RECON is able to efficiently recover native-like, biologically relevant sequences in this diverse set of protein complexes. PMID:26147100
London, Nir; Ambroggio, Xavier
2014-02-01
Computational protein design efforts aim to create novel proteins and functions in an automated manner and, in the process, these efforts shed light on the factors shaping natural proteins. The focus of these efforts has progressed from the interior of proteins to their surface and the design of functions, such as binding or catalysis. Here we examine progress in the development of robust methods for the computational design of non-natural interactions between proteins and molecular targets such as other proteins or small molecules. This problem is referred to as the de novo computational design of interactions. Recent successful efforts in de novo enzyme design and the de novo design of protein-protein interactions open a path towards solving this problem. We examine the common themes in these efforts, and review recent studies aimed at understanding the nature of successes and failures in the de novo computational design of interactions. While several approaches culminated in success, the use of a well-defined structural model for a specific binding interaction in particular has emerged as a key strategy for a successful design, and is therefore reviewed with special consideration. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Smith, Jeffrey H.; Drews, Michael
1990-01-01
The results are described of an effort to establish commonality and standardization of generic crew extravehicular (crew-EVA) and telerobotic task analysis primitives used for the study of spaceborne operations. Although direct crew-EVA plans are the most visible output of spaceborne operations, significant ongoing efforts by a wide variety of projects and organizations also require tools for estimation of crew-EVA and telerobotic times. Task analysis tools provide estimates for input to technical and cost tradeoff studies. A workshop was convened to identify the issues and needs to establish a common language and syntax for task analysis primitives. In addition, the importance of such a syntax was shown to have precedence over the level to which such a syntax is applied. The syntax, lists of crew-EVA and telerobotic primitives, and the data base in diskette form are presented.
A Large-Scale, Multiagency Approach to Defining a Reference Network for Pacific Northwest Streams
NASA Astrophysics Data System (ADS)
Miller, Stephanie; Eldred, Peter; Muldoon, Ariel; Anlauf-Dunn, Kara; Stein, Charlie; Hubler, Shannon; Merrick, Lesley; Haxton, Nick; Larson, Chad; Rehn, Andrew; Ode, Peter; Vander Laan, Jake
2016-12-01
Aquatic monitoring programs vary widely in objectives and design. However, each program faces the unifying challenge of assessing conditions and quantifying reasonable expectations for measured indicators. A common approach for setting resource expectations is to define reference conditions that represent areas of least human disturbance or most natural state of a resource characterized by the range of natural variability across a region of interest. Identification of reference sites often relies heavily on professional judgment, resulting in varying and unrepeatable methods. Standardized methods for data collection, site characterization, and reference site selection facilitate greater cooperation among assessment programs and development of assessment tools that are readily shareable and comparable. We illustrate an example that can serve the broader global monitoring community on how to create a consistent and transparent reference network for multiple stream resource agencies. We provide a case study that offers a simple example of how reference sites can be used, at the landscape level, to link upslope management practices to a specific in-channel response. We found management practices, particularly areas with high road densities, have more fine sediments than areas with fewer roads. While this example uses data from only one of the partner agencies, if data were collected in a similar manner they can be combined and create a larger, more robust dataset. We hope that this starts a dialog regarding more standardized ways through inter-agency collaborations to evaluate data. Creating more consistency in physical and biological field protocols will increase the ability to share data.
Sustainability of common pool resources
Timilsina, Raja Rajendra; Kamijo, Yoshio
2017-01-01
Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as “capitalism,” affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepalese areas: (i) rural (non-capitalistic) and (ii) urban (capitalistic) areas. We find that a proportion of prosocial individuals in urban areas is lower than that in rural areas, and urban residents deplete resources more quickly than rural residents. The composition of proself and prosocial individuals in a group and the degree of capitalism are crucial in that an increase in prosocial members in a group and the rural dummy positively affect resource sustainability by 65% and 63%, respectively. Overall, this paper shows that when societies move toward more capitalistic environments, the sustainability of common pool resources tends to decrease with the changes in individual preferences, social norms, customs and views to others through human interactions. This result implies that individuals may be losing their coordination abilities for social dilemmas of resource sustainability in capitalistic societies. PMID:28212426
Sustainability of common pool resources.
Timilsina, Raja Rajendra; Kotani, Koji; Kamijo, Yoshio
2017-01-01
Sustainability has become a key issue in managing natural resources together with growing concerns for capitalism, environmental and resource problems. We hypothesize that the ongoing modernization of competitive societies, which we refer to as "capitalism," affects human nature for utilizing common pool resources, thus compromising sustainability. To test this hypothesis, we design and implement a set of dynamic common pool resource games and experiments in the following two types of Nepalese areas: (i) rural (non-capitalistic) and (ii) urban (capitalistic) areas. We find that a proportion of prosocial individuals in urban areas is lower than that in rural areas, and urban residents deplete resources more quickly than rural residents. The composition of proself and prosocial individuals in a group and the degree of capitalism are crucial in that an increase in prosocial members in a group and the rural dummy positively affect resource sustainability by 65% and 63%, respectively. Overall, this paper shows that when societies move toward more capitalistic environments, the sustainability of common pool resources tends to decrease with the changes in individual preferences, social norms, customs and views to others through human interactions. This result implies that individuals may be losing their coordination abilities for social dilemmas of resource sustainability in capitalistic societies.
Vedsted, P; Christensen, M B
2005-02-01
To describe the basis on which our knowledge of frequent attendance in general practice rests and to propose recommendations for further research on frequent attenders (FAs). The literature review (finished February 2004) encompassed peer-reviewed articles in English describing contacts with general practice in terms of frequency. Searches were performed in the Medline, CINAHL, EMBASE, PsycINFO, Social Sciences Expanded Index and ISI Citation databases with additional searches in reference lists and the 'related articles' function in the ISI Citation database and Medline. General practice. Sixty-one articles (54 studies). The articles were assessed according to the following design variables: setting; definition of FAs; sampling; sample size; control groups; study aim; study design; data sources; effect measure; and main results. There was no generally accepted definition of frequent attendance. Research designs differed substantially. Eight articles gave sufficient information on all design variables. The top 10% of attenders accounted for 30-50% of all contacts, and up to 40% of FAs were still FAs the following year. More than 50% of FAs had a physical disease, more than 50% of FAs suffered from psychological distress, social factors (low social support, unemployment, divorce) were associated with frequent attendance in more than 50% of FAs, multiproblems (physical, psychological and social) were found in one-third of FAs, and frequent attendance was associated with increasing age and female gender. The diversity of designs, definitions and methods in the current literature on FAs in general practice hampers comparison of their precision, validity and generalizability, and calls for cautious interpretation and adoption of a common, generally acceptable definition in future studies.
DAsHER CD: Developing a Data-Oriented Human-Centric Enterprise Architecture for EarthCube
NASA Astrophysics Data System (ADS)
Yang, C. P.; Yu, M.; Sun, M.; Qin, H.; Robinson, E.
2015-12-01
One of the biggest challenges that face Earth scientists is the resource discovery, access, and sharing in a desired fashion. EarthCube is targeted to enable geoscientists to address the challenges by fostering community-governed efforts that develop a common cyberinfrastructure for the purpose of collecting, accessing, analyzing, sharing and visualizing all forms of data and related resources, through the use of advanced technological and computational capabilities. Here we design an Enterprise Architecture (EA) for EarthCube to facilitate the knowledge management, communication and human collaboration in pursuit of the unprecedented data sharing across the geosciences. The design results will provide EarthCube a reference framework for developing geoscience cyberinfrastructure collaborated by different stakeholders, and identifying topics which should invoke high interest in the community. The development of this EarthCube EA framework leverages popular frameworks, such as Zachman, Gartner, DoDAF, and FEAF. The science driver of this design is the needs from EarthCube community, including the analyzed user requirements from EarthCube End User Workshop reports and EarthCube working group roadmaps, and feedbacks or comments from scientists obtained by organizing workshops. The final product of this Enterprise Architecture is a four-volume reference document: 1) Volume one is this document and comprises an executive summary of the EarthCube architecture, serving as an overview in the initial phases of architecture development; 2) Volume two is the major body of the design product. It outlines all the architectural design components or viewpoints; 3) Volume three provides taxonomy of the EarthCube enterprise augmented with semantics relations; 4) Volume four describes an example of utilizing this architecture for a geoscience project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, Neville G.W.; Heuze, Francois E.; Miller, Hamish D.S.
1993-03-01
The reference design for the underground facilities at the Waste Isolation Pilot Plant was developed using the best criteria available at initiation of the detailed design effort. These design criteria are contained in the US Department of Energy document titled Design Criteria, Waste Isolation Pilot Plant (WIPP). Revised Mission Concept-IIA (RMC-IIA), Rev. 4, dated February 1984. The validation process described in the Design Validation Final Report has resulted in validation of the reference design of the underground openings based on these criteria. Future changes may necessitate modification of the Design Criteria document and/or the reference design. Validation of the referencemore » design as presented in this report permits the consideration of future design or design criteria modifications necessitated by these changes or by experience gained at the WIPP. Any future modifications to the design criteria and/or the reference design will be governed by a DOE Standard Operation Procedure (SOP) covering underground design changes. This procedure will explain the process to be followed in describing, evaluating and approving the change.« less
Jiao, Yong; Zhang, Yu; Wang, Yu; Wang, Bei; Jin, Jing; Wang, Xingyu
2018-05-01
Multiset canonical correlation analysis (MsetCCA) has been successfully applied to optimize the reference signals by extracting common features from multiple sets of electroencephalogram (EEG) for steady-state visual evoked potential (SSVEP) recognition in brain-computer interface application. To avoid extracting the possible noise components as common features, this study proposes a sophisticated extension of MsetCCA, called multilayer correlation maximization (MCM) model for further improving SSVEP recognition accuracy. MCM combines advantages of both CCA and MsetCCA by carrying out three layers of correlation maximization processes. The first layer is to extract the stimulus frequency-related information in using CCA between EEG samples and sine-cosine reference signals. The second layer is to learn reference signals by extracting the common features with MsetCCA. The third layer is to re-optimize the reference signals set in using CCA with sine-cosine reference signals again. Experimental study is implemented to validate effectiveness of the proposed MCM model in comparison with the standard CCA and MsetCCA algorithms. Superior performance of MCM demonstrates its promising potential for the development of an improved SSVEP-based brain-computer interface.
47 CFR 61.25 - References to other instruments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false References to other instruments. 61.25 Section 61.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) TARIFFS General Rules for Nondominant Carriers § 61.25 References to other instruments. In...
76 FR 12358 - Common Formats for Patient Safety Data Collection and Event Reporting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-07
... HHS, AHRQ coordinates the development of a set of common definitions and reporting formats (Common... unsafe conditions that increase risks and hazards to patients. Definitions and other details about PSOs... hospitals and skilled nursing facilities. Definition of Common Formats The term ``Common Formats'' refers to...
Note: Low phase noise programmable phase-locked loop with high temperature stability.
Michálek, Vojtěch; Procházka, Ivan
2017-03-01
The design and construction of low jitter programmable phase-locked loop with low temperature coefficient of phase are presented. It has been designed for demanding high precision timing applications, especially as a clock source for event timer with subpicosecond precision. The phase-locked loop itself has a jitter of few hundreds of femtoseconds. It produces square wave with programmable output frequency from 100 MHz to 500 MHz and programmable amplitude of 0.25 V to 1.2 V peak-to-peak, which is locked to 5 MHz or 10 MHz reference frequency common for disciplined oscillators and highly stable clocks such as hydrogen maser. Moreover, it comprises an on-board temperature compensated crystal oscillator for stand-alone usage. The device provides temperature coefficient of the phase lock of 0.9 ps/K near room temperature.
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
2015-01-01
This paper presents an overview of the seventh revision to an algorithm specifically designed to support NASA's Airborne Precision Spacing concept. This paper supersedes the previous documentation and presents a modification to the algorithm referred to as the Airborne Spacing for Terminal Arrival Routes version 13 (ASTAR13). This airborne self-spacing concept contains both trajectory-based and state-based mechanisms for calculating the speeds required to achieve or maintain a precise spacing interval. The trajectory-based capability allows for spacing operations prior to the aircraft being on a common path. This algorithm was also designed specifically to support a standalone, non-integrated implementation in the spacing aircraft. This current revision to the algorithm adds the state-based capability in support of evolving industry standards relating to airborne self-spacing.
NASA Technical Reports Server (NTRS)
Abbott, Terence S.; Swieringa, Kurt S.
2017-01-01
This paper presents an overview of the eighth revision to an algorithm specifically designed to support NASA's Airborne Precision Spacing concept. This paper supersedes the previous documentation and presents a modification to the algorithm referred to as the Airborne Spacing for Terminal Arrival Routes version 13 (ASTAR13). This airborne self-spacing concept contains both trajectory-based and state-based mechanisms for calculating the speeds required to achieve or maintain a precise spacing interval with another aircraft. The trajectory-based capability allows for spacing operations prior to the aircraft being on a common path. This algorithm was also designed specifically to support a standalone, non-integrated implementation in the spacing aircraft. This current revision to the algorithm supports the evolving industry standards relating to airborne self-spacing.
ERIC Educational Resources Information Center
Shaarawy, Hanaa Youssef; Lotfy, Nohayer Esmat
2013-01-01
Based on the Common European Framework of Reference (CEFR) and following a blended learning approach (a supplement model), this article reports on a quasi-experiment where writing was taught evenly with other language skills in everyday language contexts and where asynchronous online activities were required from students to extend learning beyond…
Lunar lander ground support system
NASA Technical Reports Server (NTRS)
1991-01-01
The design of the Lunar Lander Ground Support System (LLGSS) is examined. The basic design time line is around 2010 to 2030 and is referred to as a second generation system, as lunar bases and equipment would have been present. Present plans for lunar colonization call for a phased return of personnel and materials to the moons's surface. During settlement of lunar bases, the lunar lander is stationary in a very hostile environment and would have to be in a state of readiness for use in case of an emergency. Cargo and personnel would have to be removed from the lander and transported to a safe environment at the lunar base. An integrated system is required to perform these functions. These needs are addressed which center around the design of a lunar lander servicing system. The servicing system could perform several servicing functions to the lander in addition to cargo servicing. The following were considered: (1) reliquify hydrogen boiloff; (2) supply power; and (3) remove or add heat as necessary. The final design incorporates both original designs and existing vehicles and equipment on the surface of the moon at the time considered. The importance of commonality is foremost in the design of any lunar machinery.
Exploration on the matching between Optical Comprehensive Design Experiment and Washington Accord
NASA Astrophysics Data System (ADS)
Cao, Yiping; Chen, Wenjing; Zhang, Qican; Liu, Yuankun; Li, Dahai; Zhou, Xinzhi; Wei, Jun
2017-08-01
Common problems faced in optical comprehensive design experiment and going against the Washington Accord are pointed out. For resolving these problems, an instructional and innovative teaching scheme for Optics Comprehensive Design Experiment is proposed. We would like to understand the student that can improve the hands-on practical ability, theory knowledge understanding ability, complex problem solving ability, engineering application ability, cooperative ability after tracking and researching the student who have attended the class about Optical Comprehensive Design Experiment, We found that there are some problems on the course such as the experiment content vague, the student beginning less time, phase separation theory and engineering application, the experiment content lack of selectivity and so on. So we have made some improvements reference to the Washington Accord for the class teaching plan about Optical Comprehensive Design Experiment. This class must relevant to the engineering basic courses, professional foundation course and the major courses, so far as to the future study and work that which can play a role in inheriting and continuity to the students. The Optical Comprehensive Design Experiment teaching program requires students learning this course to have learnt basic courses like analog electronics technique, digital electronic technique, applied optics and computer and other related courses which students are required to comprehensively utilize. This teaching scheme contains six practical complex engineering problems which are respectively optical system design, light energy meter design, illuminometer design, material refractive index measuring system design, light intensity measuring system design and open design. Establishing the optional experiment and open experiment can provide students with a greater choice and enhance the students' creativity, vivid teaching experimental teachers and enriching contents of experiment can make the experiment more interesting, providing students with more opportunities to conduct experiment and improving students' practical ability with long learning time, putting emphasis on student's understanding of complex engineering problems and the cognitive of the process to solve complex engineering problems with actual engineering problems. Applying the scheme in other courses and improving accordingly will be able to ensure the quality of engineering education. Look forward to offering useful reference for the curriculum system construction in colleges and universities.
Wigger-Alberti, Walter; Williams, Ragna; von Mackensen, Yi-Ling; Hoffman-Wecker, Maciej; Grossmann, Ulrike; Staedtler, Gerald; Nkulikiyinka, Richard; Shakery, Kaweh
2017-01-01
Psoriasis plaque tests (PPTs) are important tools in the early phases of antipsoriatic drug development. Two distinct PPT design variants (open vs. occluded drug application) are commonly used, but no previous work has aimed to directly compare and contrast their performance. We compared the antipsoriatic efficacy of mapracorat 0.1% ointment and reference drugs reported in 2 separate studies, representing open and occluded PPT designs. The drug effect size was measured by sonography (mean change in echo-poor band thickness), chromametry, and standardized clinical assessment. Antipsoriatic effects were detectable for the study drugs in both occluded and open PPTs. Differences between the potency of antipsoriatic drugs and vehicle were observable. The total antipsoriatic effect size appeared to be higher in the occluded PPT than the open PPT, despite the shorter treatment duration (2 vs. 4 weeks). Effect dynamics over time revealed greater differences between some study drugs in the open PPT compared to the occluded PPT. Taking the higher technical challenges for the open PPT into account, we recommend the occluded PPT as a standard screening setting in early drug development. In special cases, considering certain drug aspects or study objectives that would require procedural adaptations, an open PPT could be the better-suited design. Finally, both PPT models show clear advantages: classification as phase I studies, small number of psoriatic subjects, relatively short study duration, excellent discrimination between compounds and concentrations, parallel measurement of treatment response, and go/no go decisions very early in clinical development. © 2017 S. Karger AG, Basel.
Method of pedestal and common-mode noise correction for switched-capacitor analog memories
Britton, C.L.
1997-09-23
A method and apparatus are disclosed for correcting common-mode noise and pedestal noise in a multichannel array of switched-capacitor analog memories wherein each analog memory is connected to an associated analog-to-digital converter. The apparatus comprises a single differential element in two different embodiments. In a first embodiment, the differential element is a reference analog memory connected to a buffer. In the second embodiment, the differential dement is a reference analog memory connected to a reference analog-to-digital connected to an array of digital summing circuits. 4 figs.
Method of pedestal and common-mode noise correction for switched-capacitor analog memories
Britton, C.L.
1996-12-31
A method and apparatus are disclosed for correcting common-mode noise and pedestal noise in a multichannel array of switched-capacitor analog memories wherein each analog memory is connected to an associated analog-to-digital converter. The apparatus comprises a single differential element in two different embodiments. In a first embodiment, the differential element is a reference analog memory connected to a buffer. In the second embodiment, the differential element is a reference analog memory connected to a reference analog-to-digital connected to an array of digital summing circuits. 4 figs.
Conceptual Match as a Determinant of Reference Reuse in Dialogue
ERIC Educational Resources Information Center
Knutsen, Dominique; Le Bigot, Ludovic
2017-01-01
As speakers interact, they add references to their common ground, which they can then reuse to facilitate listener comprehension. However, all references are not equally likely to be reused. The purpose of this study was to shed light on how the speakers' conceptualizations of the referents under discussion affect reuse (along with a generation…
Engaging teenagers productively in service design
Bowen, Simon; Sustar, Helena; Wolstenholme, Daniel; Dearden, Andy
2013-01-01
Engaging young people in participatory design can be challenging, particularly in health-related projects. In a study co-designing diabetes support and information services with teenagers, we found framing activities using popular culture was a useful strategy. Various cultural references helped us stage activities that were productive for the design process, and were engaging for our young participants (e.g. exploring practical implications through discussions in a ‘Dragons’ Den’). Some activities were more effective than others and the idea of language-games, which has been widely explored in participatory design, explains why our strategy was successful when there was a clear ‘family resemblance’ between the popular cultural references and certain essential stages of designing. However, attention is required in selecting appropriate cultural references if this strategy is adopted elsewhere, and design facilitators should focus first on devising accessible language-games, rather than expecting popular cultural references to provide complete solutions to the challenge of staging participatory design. PMID:26516621
Goyette, Sharon Ramos; McCoy, John G; Kennedy, Ashley; Sullivan, Meghan
2012-02-28
It has been well-established that men outperform women on some spatial tasks. The tools commonly used to demonstrate this difference (e.g. The Mental Rotations Task) typically involve problems and solutions that are presented in a context devoid of referents. The study presented here assessed whether the addition of referents (or "landmarks") would attenuate the well-established sex difference on the judgment of line orientation task (JLOT). Three versions of the JLOT were presented in a within design. The first iteration contained the original JLOT (JLOT 1). JLOT 2 contained three "landmarks" or referents and JLOT 3 contained only one landmark. The sex difference on JLOT 1 was completely negated by the addition of three landmarks on JLOT 2 or the addition of one landmark on JLOT3. In addition, salivary testosterone was measured. In men, gains in performance on the JLOT due to the addition of landmarks were positively correlated with testosterone levels. This suggests that men with the highest testosterone levels benefited the most from the addition of landmarks. These data help to highlight different strategies used by men and women to solve spatial tasks. Copyright © 2011 Elsevier Inc. All rights reserved.
47 CFR 61.74 - References to other instruments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... other document or instrument. (b) Tariffs for end-on-end through services may reference the tariffs of... 47 Telecommunication 3 2010-10-01 2010-10-01 false References to other instruments. 61.74 Section 61.74 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES...
Variation in Definition of Prolonged Mechanical Ventilation.
Rose, Louise; McGinlay, Michael; Amin, Reshma; Burns, Karen Ea; Connolly, Bronwen; Hart, Nicholas; Jouvet, Philippe; Katz, Sherri; Leasa, David; Mawdsley, Cathy; McAuley, Danny F; Schultz, Marcus J; Blackwood, Bronagh
2017-10-01
Consistency of definitional criteria for terminology applied to describe subject cohorts receiving mechanical ventilation within ICU and post-acute care settings is important for understanding prevalence, risk stratification, effectiveness of interventions, and projections for resource allocation. Our objective was to quantify the application and definition of terms for prolonged mechanical ventilation. We conducted a scoping review of studies (all designs except single-case study) reporting a study population (adult and pediatric) using the term prolonged mechanical ventilation or a synonym. We screened 5,331 references, reviewed 539 full-text references, and excluded 120. Of the 419 studies (representing 38 countries) meeting inclusion criteria, 297 (71%) reported data on a heterogeneous subject cohort, and 66 (16%) included surgical subjects only (46 of those 66, 70% cardiac surgery). Other studies described COPD (16, 4%), trauma (22, 5%), neuromuscular (17, 4%), and sepsis (1, 0.2%) cohorts. A total of 741 terms were used to refer to the 419 study cohorts. The most common terms were: prolonged mechanical ventilation (253, 60%), admission to specialized unit (107, 26%), and long-term mechanical ventilation (79, 19%). Some authors (282, 67%) defined their cohorts based on duration of mechanical ventilation, with 154 studies (55%) using this as the sole criterion. We identified 37 different durations of ventilation ranging from 5 h to 1 y, with > 21 d being the most common (28 of 282, 7%). For studies describing a surgical cohort, minimum ventilation duration required for inclusion was ≥ 24 h for 20 of 66 studies (30%). More than half of all studies (237, 57%) did not provide a reason/rationale for definitional criteria used, with only 28 studies (7%) referring to a consensus definition. We conclude that substantial variation exists in the terminology and definitional criteria for cohorts of subjects receiving prolonged mechanical ventilation. Standardization of terminology and definitional criteria is required for study data to be maximally informative. Copyright © 2017 by Daedalus Enterprises.
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Miner, Paul S.; Koppen, Sandra V.
2008-01-01
This report describes the design of the test articles and monitoring systems developed to characterize the response of a fault-tolerant computer communication system when stressed beyond the theoretical limits for guaranteed correct performance. A high-intensity radiated electromagnetic field (HIRF) environment was selected as the means of injecting faults, as such environments are known to have the potential to cause arbitrary and coincident common-mode fault manifestations that can overwhelm redundancy management mechanisms. The monitors generate stimuli for the systems-under-test (SUTs) and collect data in real-time on the internal state and the response at the external interfaces. A real-time health assessment capability was developed to support the automation of the test. A detailed description of the nature and structure of the collected data is included. The goal of the report is to provide insight into the design and operation of these systems, and to serve as a reference document for use in post-test analyses.
Spring 2013 Graduate Engineering Internship Summary
NASA Technical Reports Server (NTRS)
Ehrlich, Joshua
2013-01-01
In the spring of 2013, I participated in the National Aeronautics and Space Administration (NASA) Pathways Intern Employment Program at the Kennedy Space Center (KSC) in Florida. This was my final internship opportunity with NASA, a third consecutive extension from a summer 2012 internship. Since the start of my tenure here at KSC, I have gained an invaluable depth of engineering knowledge and extensive hands-on experience. These opportunities have granted me the ability to enhance my systems engineering approach in the field of payload design and testing as well as develop a strong foundation in the area of composite fabrication and testing for repair design on space vehicle structures. As a systems engineer, I supported the systems engineering and integration team with final acceptance testing of the Vegetable Production System, commonly referred to as Veggie. Verification and validation (V and V) of Veggie was carried out prior to qualification testing of the payload, which incorporated the process of confirming the system's design requirements dependent on one or more validation methods: inspection, analysis, demonstration, and testing.
Space Propulsion Research Facility (B-2): An Innovative, Multi-Purpose Test Facility
NASA Technical Reports Server (NTRS)
Hill, Gerald M.; Weaver, Harold F.; Kudlac, Maureen T.; Maloney, Christian T.; Evans, Richard K.
2011-01-01
The Space Propulsion Research Facility, commonly referred to as B-2, is designed to hot fire rocket engines or upper stage launch vehicles with up to 890,000 N force (200,000 lb force), after environmental conditioning of the test article in simulated thermal vacuum space environment. As NASA s third largest thermal vacuum facility, and the largest designed to store and transfer large quantities of propellant, it is uniquely suited to support developmental testing associated with large lightweight structures and Cryogenic Fluid Management (CFM) systems, as well as non-traditional propulsion test programs such as Electric and In-Space propulsion. B-2 has undergone refurbishment of key subsystems to support the NASA s future test needs, including data acquisition and controls, vacuum, and propellant systems. This paper details the modernization efforts at B-2 to support the Nation s thermal vacuum/propellant test capabilities, the unique design considerations implemented for efficient operations and maintenance, and ultimately to reduce test costs.
Design for pressure regulating components
NASA Technical Reports Server (NTRS)
Wichmann, H.
1973-01-01
The design development for Pressure Regulating Components included a regulator component trade-off study with analog computer performance verification to arrive at a final optimized regulator configuration for the Space Storable Propulsion Module, under development for a Jupiter Orbiter mission. This application requires the pressure regulator to be capable of long-term fluorine exposure. In addition, individual but basically identical (for purposes of commonality) units are required for separate oxidizer and fuel pressurization. The need for dual units requires improvement in the regulation accuracy over present designs. An advanced regulator concept was prepared featuring redundant bellows, all metallic/ceramic construction, friction-free guidance of moving parts, gas damping, and the elimination of coil springs normally used for reference forces. The activities included testing of actual size seat/poppet components to determine actual discharge coefficients and flow forces. The resulting data was inserted into the computer model of the regulator. Computer simulation of the propulsion module performance over two mission profiles indicated satisfactory minimization of propellant residual requirements imposed by regulator performance uncertainties.
Computational discovery of extremal microstructure families
Chen, Desai; Skouras, Mélina; Zhu, Bo; Matusik, Wojciech
2018-01-01
Modern fabrication techniques, such as additive manufacturing, can be used to create materials with complex custom internal structures. These engineered materials exhibit a much broader range of bulk properties than their base materials and are typically referred to as metamaterials or microstructures. Although metamaterials with extraordinary properties have many applications, designing them is very difficult and is generally done by hand. We propose a computational approach to discover families of microstructures with extremal macroscale properties automatically. Using efficient simulation and sampling techniques, we compute the space of mechanical properties covered by physically realizable microstructures. Our system then clusters microstructures with common topologies into families. Parameterized templates are eventually extracted from families to generate new microstructure designs. We demonstrate these capabilities on the computational design of mechanical metamaterials and present five auxetic microstructure families with extremal elastic material properties. Our study opens the way for the completely automated discovery of extremal microstructures across multiple domains of physics, including applications reliant on thermal, electrical, and magnetic properties. PMID:29376124
Global thermal analysis of air-air cooled motor based on thermal network
NASA Astrophysics Data System (ADS)
Hu, Tian; Leng, Xue; Shen, Li; Liu, Haidong
2018-02-01
The air-air cooled motors with high efficiency, large starting torque, strong overload capacity, low noise, small vibration and other characteristics, are widely used in different department of national industry, but its cooling structure is complex, it requires the motor thermal management technology should be high. The thermal network method is a common method to calculate the temperature field of the motor, it has the advantages of small computation time and short time consuming, it can save a lot of time in the initial design phase of the motor. The domain analysis of air-air cooled motor and its cooler was based on thermal network method, the combined thermal network model was based, the main components of motor internal and external cooler temperature were calculated and analyzed, and the temperature rise test results were compared to verify the correctness of the combined thermal network model, the calculation method can satisfy the need of engineering design, and provide a reference for the initial and optimum design of the motor.
Composing alarms: considering the musical aspects of auditory alarm design.
Gillard, Jessica; Schutz, Michael
2016-12-01
Short melodies are commonly linked to referents in jingles, ringtones, movie themes, and even auditory displays (i.e., sounds used in human-computer interactions). While melody associations can be quite effective, auditory alarms in medical devices are generally poorly learned and highly confused. Here, we draw on approaches and stimuli from both music cognition (melody recognition) and human factors (alarm design) to analyze the patterns of confusions in a paired-associate alarm-learning task involving both a standardized melodic alarm set (Experiment 1) and a set of novel melodies (Experiment 2). Although contour played a role in confusions (consistent with previous research), we observed several cases where melodies with similar contours were rarely confused - melodies holding musically distinctive features. This exploratory work suggests that salient features formed by an alarm's melodic structure (such as repeated notes, distinct contours, and easily recognizable intervals) can increase the likelihood of correct alarm identification. We conclude that the use of musical principles and features may help future efforts to improve the design of auditory alarms.
Cold Gas Content and Morphology: Scaling Relationships and Gas Deficiencies
NASA Astrophysics Data System (ADS)
Zhang, Helen; Crocker, Alison
2018-01-01
Spiral arms are a key feature of spiral galaxies. They are areas of higher gas density, and thus more stars are actively being formed in these regions. Two armed spirals are commonly referred to as ‘grand design’ spirals. In constrast, many armed spirals have three or more arms that are often less distinct. Here we present the cold gas mass per unit of stellar mass (cold gas fraction) in grand design spirals versus many armed spiral galaxies using Galaxy Zoo 2 for our morphological classifications. The masses of HI and H2 gas are taken from the COLDGASS survey, which included nondetections in the form of upper limits. Through our analysis, we found that grand design galaxies have a lower cold gas fraction of both HI and H2. This is a surprising result, given that earlier studies have shown that they have comparable rates of star formation. Combined with our result, this means that grand design galaxies must be more efficient at converting H2 gas to stars.
40 CFR 53.11 - Cancellation of reference or equivalent method designation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Cancellation of reference or equivalent method designation. 53.11 Section 53.11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General...
Kuhn, Jens H.; Andersen, Kristian G.; Bào, Yīmíng; Bavari, Sina; Becker, Stephan; Bennett, Richard S.; Bergman, Nicholas H.; Blinkova, Olga; Bradfute, Steven; Brister, J. Rodney; Bukreyev, Alexander; Chandran, Kartik; Chepurnov, Alexander A.; Davey, Robert A.; Dietzgen, Ralf G.; Doggett, Norman A.; Dolnik, Olga; Dye, John M.; Enterlein, Sven; Fenimore, Paul W.; Formenty, Pierre; Freiberg, Alexander N.; Garry, Robert F.; Garza, Nicole L.; Gire, Stephen K.; Gonzalez, Jean-Paul; Griffiths, Anthony; Happi, Christian T.; Hensley, Lisa E.; Herbert, Andrew S.; Hevey, Michael C.; Hoenen, Thomas; Honko, Anna N.; Ignatyev, Georgy M.; Jahrling, Peter B.; Johnson, Joshua C.; Johnson, Karl M.; Kindrachuk, Jason; Klenk, Hans-Dieter; Kobinger, Gary; Kochel, Tadeusz J.; Lackemeyer, Matthew G.; Lackner, Daniel F.; Leroy, Eric M.; Lever, Mark S.; Mühlberger, Elke; Netesov, Sergey V.; Olinger, Gene G.; Omilabu, Sunday A.; Palacios, Gustavo; Panchal, Rekha G.; Park, Daniel J.; Patterson, Jean L.; Paweska, Janusz T.; Peters, Clarence J.; Pettitt, James; Pitt, Louise; Radoshitzky, Sheli R.; Ryabchikova, Elena I.; Saphire, Erica Ollmann; Sabeti, Pardis C.; Sealfon, Rachel; Shestopalov, Aleksandr M.; Smither, Sophie J.; Sullivan, Nancy J.; Swanepoel, Robert; Takada, Ayato; Towner, Jonathan S.; van der Groen, Guido; Volchkov, Viktor E.; Volchkova, Valentina A.; Wahl-Jensen, Victoria; Warren, Travis K.; Warfield, Kelly L.; Weidmann, Manfred; Nichol, Stuart T.
2014-01-01
Sequence determination of complete or coding-complete genomes of viruses is becoming common practice for supporting the work of epidemiologists, ecologists, virologists, and taxonomists. Sequencing duration and costs are rapidly decreasing, sequencing hardware is under modification for use by non-experts, and software is constantly being improved to simplify sequence data management and analysis. Thus, analysis of virus disease outbreaks on the molecular level is now feasible, including characterization of the evolution of individual virus populations in single patients over time. The increasing accumulation of sequencing data creates a management problem for the curators of commonly used sequence databases and an entry retrieval problem for end users. Therefore, utilizing the data to their fullest potential will require setting nomenclature and annotation standards for virus isolates and associated genomic sequences. The National Center for Biotechnology Information’s (NCBI’s) RefSeq is a non-redundant, curated database for reference (or type) nucleotide sequence records that supplies source data to numerous other databases. Building on recently proposed templates for filovirus variant naming [
Synthetic Aziridines in Medicinal Chemistry: A Mini-Review.
Singh, Girija S
2016-01-01
Azaheterocyclic compounds are well-known to have diverse types of biological activity. Among them, azacyclopropanes, commonly referred as aziridines, occupy a prominent place in synthetic organic and medicinal chemistry due to its occurrence in natural resources, complexity involved in synthesis due to ring-strain, building blocks in organic synthesis, and its biological properties. Several novel compounds containing aziridine ring have been designed and synthesized recently by medicinal chemists for evaluating their biological profile. A number of compounds are reported as cysteine protease inhibitors, antibacterial, antifungal, anticancer, antileishmanial, and antimalarial agents. This review article summarizes the biological activity of such compounds. The preparation of such compounds is also described.
NASA Technical Reports Server (NTRS)
1991-01-01
This document presents trade studies and reference concept designs accomplished during a study of Space Transfer Concepts and Analyses for Exploration Missions (STCAEM). This volume contains the major top level trades, level 2 trades conducted in support of NASA's Lunar/Mars Exploration Program Office, and a synopsis of the vehicles for different propulsion systems under trade consideration. The vehicles are presented in more detail in other volumes of this report. Book 1 of Volume 1 covers the following analyses: lunar/Mars commonality trades, lunar/Mars mission operations, and Mars transfer systems.
Taveira-Gomes, Tiago; Ferreira, Patrícia; Taveira-Gomes, Isabel; Severo, Milton; Ferreira, Maria Amélia
2016-08-01
Computer-based learning (CBL) has been widely used in medical education, and reports regarding its usage and effectiveness have ranged broadly. Most work has been done on the effectiveness of CBL approaches versus traditional methods, and little has been done on the comparative effects of CBL versus CBL methodologies. These findings urged other authors to recommend such studies in hopes of improving knowledge about which CBL methods work best in which settings. In this systematic review, we aimed to characterize recent studies of the development of software platforms and interventions in medical education, search for common points among studies, and assess whether recommendations for CBL research are being taken into consideration. We conducted a systematic review of the literature published from 2003 through 2013. We included studies written in English, specifically in medical education, regarding either the development of instructional software or interventions using instructional software, during training or practice, that reported learner attitudes, satisfaction, knowledge, skills, or software usage. We conducted 2 latent class analyses to group articles according to platform features and intervention characteristics. In addition, we analyzed references and citations for abstracted articles. We analyzed 251 articles. The number of publications rose over time, and they encompassed most medical disciplines, learning settings, and training levels, totaling 25 different platforms specifically for medical education. We uncovered 4 latent classes for educational software, characteristically making use of multimedia (115/251, 45.8%), text (64/251, 25.5%), Web conferencing (54/251, 21.5%), and instructional design principles (18/251, 7.2%). We found 3 classes for intervention outcomes: knowledge and attitudes (175/212, 82.6%), knowledge, attitudes, and skills (11.8%), and online activity (12/212, 5.7%). About a quarter of the articles (58/227, 25.6%) did not hold references or citations in common with other articles. The number of common references and citations increased in articles reporting instructional design principles (P=.03), articles measuring online activities (P=.01), and articles citing a review by Cook and colleagues on CBL (P=.04). There was an association between number of citations and studies comparing CBL versus CBL, independent of publication date (P=.02). Studies in this field vary highly, and a high number of software systems are being developed. It seems that past recommendations regarding CBL interventions are being taken into consideration. A move into a more student-centered model, a focus on implementing reusable software platforms for specific learning contexts, and the analysis of online activity to track and predict outcomes are relevant areas for future research in this field.
Physiology and pathophysiology of potassium homeostasis.
Palmer, Biff F; Clegg, Deborah J
2016-12-01
Total body potassium content and proper distribution of potassium across the cell membrane is of critical importance for normal cellular function. Potassium homeostasis is maintained by several different methods. In the kidney, total body potassium content is achieved by alterations in renal excretion of potassium in response to variations in intake. Insulin and beta-adrenergic tone play critical roles in maintaining the internal distribution of potassium under normal conditions. Despite homeostatic pathways designed to maintain potassium levels within the normal range, disorders of altered potassium homeostasis are common. The clinical approach to designing effective treatments relies on understanding the pathophysiology and regulatory influences which govern the internal distribution and external balance of potassium. Here we provide an overview of the key regulatory aspects of normal potassium physiology. This review is designed to provide an overview of potassium homeostasis as well as provide references of seminal papers to guide the reader into a more in depth discussion of the importance of potassium balance. This review is designed to be a resource for educators and well-informed clinicians who are teaching trainees about the importance of potassium balance. Copyright © 2016 the American Physiological Society.
ERIC Educational Resources Information Center
Little, David
2016-01-01
I begin this article by briefly explaining why I think CercleS should encourage university language centres to align their courses and assessment with the proficiency levels of the "Common European Framework of Reference for Languages" (CEFR) and why they should use a version of the European Language Portfolio (ELP) to support the…
Wide field of view common-path lateral-shearing digital holographic interference microscope
NASA Astrophysics Data System (ADS)
Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun
2017-12-01
Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes.
Wide field of view common-path lateral-shearing digital holographic interference microscope.
Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun
2017-12-01
Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
40 CFR 53.8 - Designation of reference and equivalent methods.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Designation of reference and equivalent methods. 53.8 Section 53.8 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS General Provisions § 53.8...
NASA Astrophysics Data System (ADS)
Andersson, C. David; Hillgren, J. Mikael; Lindgren, Cecilia; Qian, Weixing; Akfur, Christine; Berg, Lotta; Ekström, Fredrik; Linusson, Anna
2015-03-01
Scientific disciplines such as medicinal- and environmental chemistry, pharmacology, and toxicology deal with the questions related to the effects small organic compounds exhort on biological targets and the compounds' physicochemical properties responsible for these effects. A common strategy in this endeavor is to establish structure-activity relationships (SARs). The aim of this work was to illustrate benefits of performing a statistical molecular design (SMD) and proper statistical analysis of the molecules' properties before SAR and quantitative structure-activity relationship (QSAR) analysis. Our SMD followed by synthesis yielded a set of inhibitors of the enzyme acetylcholinesterase (AChE) that had very few inherent dependencies between the substructures in the molecules. If such dependencies exist, they cause severe errors in SAR interpretation and predictions by QSAR-models, and leave a set of molecules less suitable for future decision-making. In our study, SAR- and QSAR models could show which molecular sub-structures and physicochemical features that were advantageous for the AChE inhibition. Finally, the QSAR model was used for the prediction of the inhibition of AChE by an external prediction set of molecules. The accuracy of these predictions was asserted by statistical significance tests and by comparisons to simple but relevant reference models.
Possible Overlaps Between Blobs, Grism Apertures, and Dithers
NASA Astrophysics Data System (ADS)
Ryan, R. E.; McCullough, P. R.
2017-06-01
We present a investigation into possible overlaps between the known IR blobs with the grism aperture reference positions and the IR dither patterns. Each aperture was designed to place the science target (e.g. a specific star) on a cosmetically clean area of the IR detector. Similarly, the dither patterns were designed to mitigate cosmetic defects by rarely (or ideally never) placing such targets on known defects. Because blobs accumulate with time, the originally defined apertures and dither patterns may no longer accomplish their goals, it is important to reverify these combinations. We find two potential overlaps between the blob, aperture, and dither combinations, but do not recommend any changes to the current suite of aperture references positions and/or dither patterns for two reasons. First, one of the overlaps occurs with a dither/aperture combination that is seldom used for high-value science operations, but rather more common for wide-field surveys/mosaics. Second, the other overlap is 8.7 pix from a blob that has a fiducial radius of 10 pix, which already represents a very conservative distance. We conclude that a similar analysis should be repeated as new blobs occur, to continue to ensure ideal operations for high-value science targets. The purpose of this report is to document the analysis in order to facilitate its repetition in the future.
miRiadne: a web tool for consistent integration of miRNA nomenclature.
Bonnal, Raoul J P; Rossi, Riccardo L; Carpi, Donatella; Ranzani, Valeria; Abrignani, Sergio; Pagani, Massimiliano
2015-07-01
The miRBase is the official miRNA repository which keeps the annotation updated on newly discovered miRNAs: it is also used as a reference for the design of miRNA profiling platforms. Nomenclature ambiguities generated by loosely updated platforms and design errors lead to incompatibilities among platforms, even from the same vendor. Published miRNA lists are thus generated with different profiling platforms that refer to diverse and not updated annotations. This greatly compromises searches, comparisons and analyses that rely on miRNA names only without taking into account the mature sequences, which is particularly critic when such analyses are carried over automatically. In this paper we introduce miRiadne, a web tool to harmonize miRNA nomenclature, which takes into account the original miRBase versions from 10 up to 21, and annotations of 40 common profiling platforms from nine brands that we manually curated. miRiadne uses the miRNA mature sequence to link miRBase versions and/or platforms to prevent nomenclature ambiguities. miRiadne was designed to simplify and support biologists and bioinformaticians in re-annotating their own miRNA lists and/or data sets. As Ariadne helped Theseus in escaping the mythological maze, miRiadne will help the miRNA researcher in escaping the nomenclature maze. miRiadne is freely accessible from the URL http://www.miriadne.org. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Portrayal of Alcohol Intoxication on YouTube
Primack, Brian A.; Colditz, Jason B.; Pang, Kevin C.; Jackson, Kristina M.
2015-01-01
Background We aimed to characterize the content of leading YouTube videos related to alcohol intoxication and to examine factors associated with alcohol intoxication in videos that were assessed positively by viewers. Methods We systematically captured the 70 most relevant and popular videos on YouTube related to alcohol intoxication. We employed an iterative process to codebook development which resulted in 42 codes in 6 categories: video characteristics, character socio-demographics, alcohol depiction, degree of alcohol use, characteristics associated with alcohol, and consequences of alcohol. Results There were a total of 333,246,875 views for all videos combined. While 89% of videos involved males, only 49% involved females. The videos had a median of 1646 (IQR 300-22,969) “like” designations and 33 (IQR 14-1,261) “dislike” designations each. Liquor was most frequently represented, followed by beer and then wine/champagne. Nearly one-half (44%) of videos contained a brand reference. Humor was juxtaposed with alcohol use in 79% of videos, and motor vehicle use was present in 24%. There were significantly more likes per dislike, indicating more positive sentiment, when there was representation of liquor (29.1 vs. 11.4, p = .008), brand references (32.1 vs. 19.2, p = .04), and/or physical attractiveness (67.5 vs. 17.8, p < .001). Conclusions Internet videos depicting alcohol intoxication are heavily viewed. Nearly half of these videos involve a brand-name reference. While these videos commonly juxtapose alcohol intoxication with characteristics such as humor and attractiveness, they infrequently depict negative clinical outcomes. The popularity of this site may provide an opportunity for public health intervention. PMID:25703135
NASA Technical Reports Server (NTRS)
Binkley, David M.; Verma, Nikhil; Crawford, Robert L.; Brandon, Erik; Jackson, Thomas N.
2004-01-01
Organic strain gauge and other sensors require high-gain, precision dc amplification to process their low-level output signals. Ideally, amplifiers would be fabricated using organic thin-film field-effect transistors (OTFT's) adjacent to the sensors. However, OTFT amplifiers exhibit low gain and high input-referred dc offsets that must be effectively managed. This paper presents a four-stage, cascaded differential OTFT amplifier utilizing switched capacitor auto-zeroing. Each stage provides a nominal voltage gain of four through a differential pair driving low-impedance active loads, which provide common-mode output voltage control. p-type pentacence OTFT's are used for the amplifier devices and auto-zero switches. Simulations indicate the amplifier provides a nominal voltage gain of 280 V/V and effectively amplifies a 1-mV dc signal in the presence of 500-mV amplifier input-referred dc offset voltages. Future work could include the addition of digital gain calibration and offset correction of residual offsets associated with charge injection imbalance in the differential circuits.
Proposal for the nomenclature of human plasminogen (PLG) polymorphism.
Skoda, U; Bertrams, J; Dykes, D; Eiberg, H; Hobart, M; Hummel, K; Kühnl, P; Mauff, G; Nakamura, S; Nishimukai, H
1986-01-01
Since its discovery, human plasminogen (PLG) polymorphism has received widespread acceptance in population genetics and forensic haematology. Due to the large number of variant alleles described, a PLG reference typing and Plasminogen Symposium was held, at which a nomenclature proposal was inaugurated. The technology of comparing PLG variants was based on isoelectric focusing and subsequent detection by caseinolytic overlay and 'Western' blotting. Typing results permitted comparison of so far described variant designations and resulted in a new nomenclature proposal for PLG polymorphism. It is recommended that the two most common alleles found in all investigated races be called: PLG*A (previously also PLG*1) and PLG*B (previously also PLG*2), the known variants with acidic pI: PLG*A1 to *A3, intermediate variants: PLG*M1 to *M5, PLG*M5 being functionally inactive, and basic variants: PLG*B1 to *B3. For future classification of newly discovered variants, samples should be compared at any of the laboratories participating in the reference typing.
Miotke, Laura; Lau, Billy T; Rumma, Rowza T; Ji, Hanlee P
2014-03-04
In this study, we present a highly customizable method for quantifying copy number and point mutations utilizing a single-color, droplet digital PCR platform. Droplet digital polymerase chain reaction (ddPCR) is rapidly replacing real-time quantitative PCR (qRT-PCR) as an efficient method of independent DNA quantification. Compared to quantative PCR, ddPCR eliminates the needs for traditional standards; instead, it measures target and reference DNA within the same well. The applications for ddPCR are widespread including targeted quantitation of genetic aberrations, which is commonly achieved with a two-color fluorescent oligonucleotide probe (TaqMan) design. However, the overall cost and need for optimization can be greatly reduced with an alternative method of distinguishing between target and reference products using the nonspecific DNA binding properties of EvaGreen (EG) dye. By manipulating the length of the target and reference amplicons, we can distinguish between their fluorescent signals and quantify each independently. We demonstrate the effectiveness of this method by examining copy number in the proto-oncogene FLT3 and the common V600E point mutation in BRAF. Using a series of well-characterized control samples and cancer cell lines, we confirmed the accuracy of our method in quantifying mutation percentage and integer value copy number changes. As another novel feature, our assay was able to detect a mutation comprising less than 1% of an otherwise wild-type sample, as well as copy number changes from cancers even in the context of significant dilution with normal DNA. This flexible and cost-effective method of independent DNA quantification proves to be a robust alternative to the commercialized TaqMan assay.
Content Analysis of Tobacco, Alcohol, and Other Drugs in Popular Music
Primack, Brian A.; Dalton, Madeline A.; Carroll, Mary V.; Agarwal, Aaron A.; Fine, Michael J.
2010-01-01
Objective To perform a comprehensive content analysis of substance use in contemporary popular music. Design We analyzed the 279 most popular songs of 2005 according to Billboard magazine. Two coders working independently used a standardized data collection instrument to code portrayals of substance use. Outcome Measures Presence and explicit use of substances and motivations for, associations with, and consequences of substance use. Results Of the 279 songs, 93 (33.3%) portrayed substance use, with an average of 35.2 substance references per song-hour. Portrayal of substance use varied significantly (P<.001) by genre, with 1 or more references in 3 of 35 pop songs (9%), 9 of 66 rock songs (14%), 11 of 55 R&B/hip-hop songs (20%), 22 of 61 country songs (36%), and 48 of 62 rap songs (77%). While only 2.9% of the 279 songs portrayed tobacco use, 23.7% depicted alcohol use, 13.6% depicted marijuana use, and 11.5% depicted other or unspecified substance use. In the 93 songs with substance use, it was most often motivated by peer/social pressure (45 [48%]) or sex (28 [30%]); use was commonly associated with partying (50 [54%]), sex (43 [46%]), violence (27 [29%]), and/or humor (22 [24%]). Only 4 songs (4%) contained explicit antiuse messages, and none portrayed substance refusal. Most songs with substance use (63 [68%]) portrayed more positive than negative consequences; these positive consequences were most commonly social, sexual, financial, or emotional. Conclusions The average adolescent is exposed to approximately 84 references to explicit substance use daily in popular songs, and this exposure varies widely by musical genre. The substance use depicted in popular music is frequently motivated by peer acceptance and sex, and it has highly positive associations and consequences. PMID:18250243
Nasr Esfahani, Bahram; Rezaei Yazdi, Hadi; Moghim, Sharareh; Ghasemian Safaei, Hajieh; Zarkesh Esfahani, Hamid
2012-11-01
Rapid and accurate identification of mycobacteria isolates from primary culture is important due to timely and appropriate antibiotic therapy. Conventional methods for identification of Mycobacterium species based on biochemical tests needs several weeks and may remain inconclusive. In this study, a novel multiplex real-time PCR was developed for rapid identification of Mycobacterium genus, Mycobacterium tuberculosis complex (MTC) and the most common non-tuberculosis mycobacteria species including M. abscessus, M. fortuitum, M. avium complex, M. kansasii, and the M. gordonae in three reaction tubes but under same PCR condition. Genetic targets for primer designing included the 16S rDNA gene, the dnaJ gene, the gyrB gene and internal transcribed spacer (ITS). Multiplex real-time PCR was setup with reference Mycobacterium strains and was subsequently tested with 66 clinical isolates. Results of multiplex real-time PCR were analyzed with melting curves and melting temperature (T (m)) of Mycobacterium genus, MTC, and each of non-tuberculosis Mycobacterium species were determined. Multiplex real-time PCR results were compared with amplification and sequencing of 16S-23S rDNA ITS for identification of Mycobacterium species. Sensitivity and specificity of designed primers were each 100 % for MTC, M. abscessus, M. fortuitum, M. avium complex, M. kansasii, and M. gordonae. Sensitivity and specificity of designed primer for genus Mycobacterium was 96 and 100 %, respectively. According to the obtained results, we conclude that this multiplex real-time PCR with melting curve analysis and these novel primers can be used for rapid and accurate identification of genus Mycobacterium, MTC, and the most common non-tuberculosis Mycobacterium species.
Paraquat dichloride, commonly referred to as “paraquat,” is one of the most widely used herbicides registered in the United States. Paraquat is also often referred to as Gramoxone (a popular end-use product).
Design and operation of a Loran-C time reference station
NASA Technical Reports Server (NTRS)
Putkovich, K.
1974-01-01
Some of the practical questions that arise when one decides to use Loran-C in a time reference system are explored. An extensive effort is made to provide basic, practical information on establishing and operating a reference station. Four areas were covered: (1) the design, configuration and operational concepts which should be considered prior to establishing and operating a reference station using Loran-C, (2) the options and tradeoffs available regarding capabilities, cost, size, versatility, ease of operation, etc., that are available to the designer, (3) what measurements are made, how they are made and what they mean, and (4) the experience the U.S. Naval Observatory Time Service Division has had in the design and operation of such stations.
Harmonising Reference Intervals for Three Calculated Parameters used in Clinical Chemistry.
Hughes, David; Koerbin, Gus; Potter, Julia M; Glasgow, Nicholas; West, Nic; Abhayaratna, Walter P; Cavanaugh, Juleen; Armbruster, David; Hickman, Peter E
2016-08-01
For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium. The Aussie Normals study was an a priori study that analysed samples from 1856 healthy volunteers. The nine analytes used for the calculations in this study were measured on Abbott Architect analysers. The data demonstrated normal (Gaussian) distributions for the albumin-adjusted serum calcium, the anion gap (using potassium in the calculation) and the calculated serum osmolality (using both the Bhagat et al. and Smithline and Gardner formulae). To assess the suitability of these reference intervals for use as harmonised reference intervals, we reviewed data from the Royal College of Pathologists of Australasia/Australasian Association of Clinical Biochemists (RCPA/AACB) bias survey. We conclude that the reference intervals for the calculated serum osmolality (using the Smithline and Gardner formulae) may be suitable for use as a common reference interval. Although a common reference interval for albumin-adjusted serum calcium may be possible, further investigations (including a greater range of albumin concentrations) are needed. This is due to the bias between the Bromocresol Green (BCG) and Bromocresol Purple (BCP) methods at lower serum albumin concentrations. Problems with the measurement of Total CO 2 in the bias survey meant that we could not use the data for assessing the suitability of a common reference interval for the anion gap. Further study is required.
Ding, G; Tian, Y; Zhang, Y; Pang, Y; Zhang, J S; Zhang, J
2013-12-01
To determine whether the recently published A global reference for fetal-weight and birthweight percentiles (Global Reference) improves small- (SGA), appropriate- (AGA), and large-for-gestational-age (LGA) definitions in predicting infant mortality. Population-based cohort study. The US Linked Livebirth and Infant Death records between 1995 and 2004. Singleton births with birthweight >500 g born at 24-41 weeks of gestation. We compared infant mortality rates of SGA, AGA, and LGA infants classified by three different references: the Global Reference; a commonly used birthweight reference; and Hadlock's ultrasound reference. Infant mortality rates. Among 33 997 719 eligible liveborn singleton births, 25% of preterm and 9% of term infants were classified differently for SGA, AGA, and LGA by the Global Reference and the birthweight reference. The Global Reference indicated higher mortality rates in preterm SGA and preterm LGA infants than the birthweight reference. The mortality rate was considerably higher in infants classified as preterm SGA by the Global Reference but not by the birthweight reference, compared with the corresponding infants classified by the birthweight reference but not by the Global Reference (105.7 versus 12.9 per 1000, RR 8.17, 95% CI 7.38-9.06). Yet, the differences in mortality rates were much smaller in term infants than in preterm infants. Black infants had a particularly higher mortality rate than other races in AGA and LGA preterm and term infants. In respect to the commonly used birthweight reference, the Global Reference increases the identification of infant deaths by improved classification of abnormal newborn size at birth, and these advantages were more obvious in preterm than in term infants. © 2013 RCOG.
Team X Spacecraft Instrument Database Consolidation
NASA Technical Reports Server (NTRS)
Wallenstein, Kelly A.
2005-01-01
In the past decade, many changes have been made to Team X's process of designing each spacecraft, with the purpose of making the overall procedure more efficient over time. One such improvement is the use of information databases from previous missions, designs, and research. By referring to these databases, members of the design team can locate relevant instrument data and significantly reduce the total time they spend on each design. The files in these databases were stored in several different formats with various levels of accuracy. During the past 2 months, efforts have been made in an attempt to combine and organize these files. The main focus was in the Instruments department, where spacecraft subsystems are designed based on mission measurement requirements. A common database was developed for all instrument parameters using Microsoft Excel to minimize the time and confusion experienced when searching through files stored in several different formats and locations. By making this collection of information more organized, the files within them have become more easily searchable. Additionally, the new Excel database offers the option of importing its contents into a more efficient database management system in the future. This potential for expansion enables the database to grow and acquire more search features as needed.
Database Are Not Toasters: A Framework for Comparing Data Warehouse Appliances
NASA Astrophysics Data System (ADS)
Trajman, Omer; Crolotte, Alain; Steinhoff, David; Nambiar, Raghunath Othayoth; Poess, Meikel
The success of Business Intelligence (BI) applications depends on two factors, the ability to analyze data ever more quickly and the ability to handle ever increasing volumes of data. Data Warehouse (DW) and Data Mart (DM) installations that support BI applications have historically been built using traditional architectures either designed from the ground up or based on customized reference system designs. The advent of Data Warehouse Appliances (DA) brings packaged software and hardware solutions that address performance and scalability requirements for certain market segments. The differences between DAs and custom installations make direct comparisons between them impractical and suggest the need for a targeted DA benchmark. In this paper we review data warehouse appliances by surveying thirteen products offered today. We assess the common characteristics among them and propose a classification for DA offerings. We hope our results will help define a useful benchmark for DAs.
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
2015-01-01
This paper presents an overview of the fifth revision to an algorithm specifically designed to support NASA's Airborne Precision Spacing concept. This algorithm is referred to as the Airborne Spacing for Terminal Arrival Routes version 12 (ASTAR12). This airborne self-spacing concept is trajectory-based, allowing for spacing operations prior to the aircraft being on a common path. Because this algorithm is trajectory-based, it also has the inherent ability to support required-time-of- arrival (RTA) operations. This algorithm was also designed specifically to support a standalone, non-integrated implementation in the spacing aircraft. This current revision to the algorithm includes a ground speed feedback term to compensate for slower than expected traffic aircraft speeds based on the accepted air traffic control tendency to slow aircraft below the nominal arrival speeds when they are farther from the airport.
Practical Techniques for Modeling Gas Turbine Engine Performance
NASA Technical Reports Server (NTRS)
Chapman, Jeffryes W.; Lavelle, Thomas M.; Litt, Jonathan S.
2016-01-01
The cost and risk associated with the design and operation of gas turbine engine systems has led to an increasing dependence on mathematical models. In this paper, the fundamentals of engine simulation will be reviewed, an example performance analysis will be performed, and relationships useful for engine control system development will be highlighted. The focus will be on thermodynamic modeling utilizing techniques common in industry, such as: the Brayton cycle, component performance maps, map scaling, and design point criteria generation. In general, these topics will be viewed from the standpoint of an example turbojet engine model; however, demonstrated concepts may be adapted to other gas turbine systems, such as gas generators, marine engines, or high bypass aircraft engines. The purpose of this paper is to provide an example of gas turbine model generation and system performance analysis for educational uses, such as curriculum creation or student reference.
Home noninvasive ventilation: what does the anesthesiologist need to know?
Brown, Karen A; Bertolizio, Gianluca; Leone, Marisa; Dain, Steven L
2012-09-01
Treatment of chronic respiratory failure with noninvasive ventilation (NIV) is standard pediatric practice, and NIV systems are commonly used in the home setting. Although practice guidelines on the perioperative management of children supported with home NIV systems have yet to be published, increasingly these patients are referred for consultation regarding perioperative management. Just as knowledge of pharmacology underlies the safe prescription of medication, so too knowledge of biomedical design is necessary for the safe prescription of NIV therapy. The medical device design requirements developed by the Organization for International Standardization provide a framework to rationalize the safe prescription of NIV for hospitalized patients supported at home with NIV systems. This review article provides an overview of the indications for home NIV therapy, an overview of the medical devices currently available to deliver it, and a specific discussion of the management conundrums confronting anesthesiologists.
Rahnema, C D; Crosnoe, L E; Kim, E D
2015-03-01
Colloquially referred to by various misleading monikers ('pro-hormones', 'natural steroids', 'testosterone boosters', etc.) designer anabolic steroids have been popular now for over a decade as a way to achieve classic anabolic steroid-like results from products sold in the legal marketplace. Recent evidence suggests that anabolic steroid use may be the most common cause of hypogonadism in men of reproductive age. Despite recent regulatory efforts that have banned specific compounds, many anabolic-androgenic steroids (AAS) remain available in over-the-counter dietary supplements that are legally sold in the United States. Severe side effects including hepatotoxicity, cholestasis, renal failure, hypogonadism, gynecomastia, and infertility have been reported secondary to the use of these products. While some of these side effects may be reversible, more aggressive use may result in more permanent end-organ damage as has been previously described for the case of aggressive AAS users (Rahnema et al., Fertil Steril, 2014). Designer AAS remain easily available for purchase in over-the-counter bodybuilding supplements and these products appear to be increasingly popular, despite the known health risks associated with their use. We conducted a systematic search to identify the designer steroids that are most commonly sold in dietary supplements as of April 2014 and review what is known regarding their potency and toxicity. We propose that the impact of AAS use on the reproductive and hormonal health of men is underestimated in the literature owing to previous studies' failure to account for designer steroid use. Lastly, we make clinical recommendations to help physicians steer patients away from potentially harmful supplements, and summarize key regulatory obstacles that have allowed potent androgens to remain unregulated in the legal marketplace. © 2015 American Society of Andrology and European Academy of Andrology.
Recursive formulae and performance comparisons for first mode dynamics of periodic structures
NASA Astrophysics Data System (ADS)
Hobeck, Jared D.; Inman, Daniel J.
2017-05-01
Periodic structures are growing in popularity especially in the energy harvesting and metastructures communities. Common types of these unique structures are referred to in the literature as zigzag, orthogonal spiral, fan-folded, and longitudinal zigzag structures. Many of these studies on periodic structures have two competing goals in common: (a) minimizing natural frequency, and (b) minimizing mass or volume. These goals suggest that no single design is best for all applications; therefore, there is a need for design optimization and comparison tools which first require efficient easy-to-implement models. All available structural dynamics models for these types of structures do provide exact analytical solutions; however, they are complex requiring tedious implementation and providing more information than necessary for practical applications making them computationally inefficient. This paper presents experimentally validated recursive models that are able to very accurately and efficiently predict the dynamics of the four most common types of periodic structures. The proposed modeling technique employs a combination of static deflection formulae and Rayleigh’s Quotient to estimate the first mode shape and natural frequency of periodic structures having any number of beams. Also included in this paper are the results of an extensive experimental validation study which show excellent agreement between model prediction and measurement. Lastly, the proposed models are used to evaluate the performance of each type of structure. Results of this performance evaluation reveal key advantages and disadvantages associated with each type of structure.
NASA Astrophysics Data System (ADS)
MacDonald, Teresa Elise
This exploratory study sought to investigate the influence of tree graphic design---specifically linear versus branching depictions of taxa---on visitors in three different age groups (aged 11-13, 14-18, adults) interpretation and understanding using a multiple-case study strategy. The findings from this research indicate that linear and branched depictions elicit qualitatively different narratives and explanations about the relationships between the taxa in all age groups. Branched tree graphics support scientifically appropriate explanations of evolutionary relationships, i.e. that taxa are related via shared or common ancestry; while linear representations reinforce intuitive interpretations of ancestor-descendant or anagenic relationships. Furthermore, differences in the language used for linear and branched trees suggests that there is a spectrum within an analogy of developmental change that is thought to serve as a transitional concept between intuitive and scientific understanding--with 'evolved from' for branched depictions of taxa representing a shift towards an interpretation of shared ancestry rather than an individual transformation from one thing into another. In addition, branched graphics appear to support the correct reading and interpretation of shared or common ancestry in tree diagrams. Mixed reasoning was common and overall reasoning patterns were broadly similar among participants in all age groups, however, older youth (aged 14 to 18) and adults often provided more detail in their explanations and sometimes included references to evolutionary ideas such as variation, inheritance and selection.
MSDS sky reference and preamplifier study
NASA Technical Reports Server (NTRS)
Larsen, L.; Stewart, S.; Lambeck, P.
1974-01-01
The major goals in re-designing the Multispectral Scanner and Data System (MSDS) sky reference are: (1) to remove the sun-elevation angle and aircraft-attitude angle dependence from the solar-sky illumination measurement, and (2) to obtain data on the optical state of the atmosphere. The present sky reference is dependent on solar elevation and provides essentially no information on important atmospheric parameters. Two sky reference designs were tested. One system is built around a hyperbolic mirror and the reflection approach. A second approach to a sky reference utilizes a fish-eye lens to obtain a 180 deg field of view. A detailed re-design of the present sky reference around the fish-eye approach, even with its limitations, is recommended for the MSDS system. A preamplifier study was undertaken to find ways of improving the noise-equivalent reflectance by reducing the noise level for silicon detector channels on the MSDS.
Parametric study of potential early commercial MHD power plants
NASA Technical Reports Server (NTRS)
Hals, F. A.
1979-01-01
Three different reference power plant configurations were considered with parametric variations of the various design parameters for each plant. Two of the reference plant designs were based on the use of high temperature regenerative air preheaters separately fired by a low Btu gas produced from a coal gasifier which was integrated with the power plant. The third reference plant design was based on the use of oxygen enriched combustion air preheated to a more moderate temperature in a tubular type metallic recuperative heat exchanger which is part of the bottoming plant heat recovery system. Comparative information was developed on plant performance and economics. The highest net plant efficiency of about 45 percent was attained by the reference plant design with the use of a high temperature air preheater separately fired with the advanced entrained bed gasifier. The use of oxygen enrichment of the combustion air yielded the lowest cost of generating electricity at a slightly lower plant efficiency. Both of these two reference plant designs are identified as potentially attractive for early MHD power plant applications.
Chase, John H; Bolyen, Evan; Rideout, Jai Ram; Caporaso, J Gregory
2016-01-01
The number of samples in high-throughput comparative "omics" studies is increasing rapidly due to declining experimental costs. To keep sample data and metadata manageable and to ensure the integrity of scientific results as the scale of these projects continues to increase, it is essential that we transition to better-designed sample identifiers. Ideally, sample identifiers should be globally unique across projects, project teams, and institutions; short (to facilitate manual transcription); correctable with respect to common types of transcription errors; opaque, meaning that they do not contain information about the samples; and compatible with existing standards. We present cual-id, a lightweight command line tool that creates, or mints, sample identifiers that meet these criteria without reliance on centralized infrastructure. cual-id allows users to assign universally unique identifiers, or UUIDs, that are globally unique to their samples. UUIDs are too long to be conveniently written on sampling materials, such as swabs or microcentrifuge tubes, however, so cual-id additionally generates human-friendly 4- to 12-character identifiers that map to their UUIDs and are unique within a project. By convention, we use "cual-id" to refer to the software, "CualID" to refer to the short, human-friendly identifiers, and "UUID" to refer to the globally unique identifiers. CualIDs are used by humans when they manually write or enter identifiers, while the longer UUIDs are used by computers to unambiguously reference a sample. Finally, cual-id optionally generates printable label sticker sheets containing Code 128 bar codes and CualIDs for labeling of sample collection and processing materials. IMPORTANCE The adoption of identifiers that are globally unique, correctable, and easily handwritten or manually entered into a computer will be a major step forward for sample tracking in comparative omics studies. As the fields transition to more-centralized sample management, for example, across labs within an institution, across projects funded under a common program, or in systems designed to facilitate meta- and/or integrated analysis, sample identifiers generated with cual-id will not need to change; thus, costly and error-prone updating of data and metadata identifiers will be avoided. Further, using cual-id will ensure that transcription errors in sample identifiers do not require the discarding of otherwise-useful samples that may have been expensive to obtain. Finally, cual-id is simple to install and use and is free for all use. No centralized infrastructure is required to ensure global uniqueness, so it is feasible for any lab to get started using these identifiers within their existing infrastructure.
Genetics Home Reference: oculopharyngeal muscular dystrophy
... This condition is much more common in the French-Canadian population of the Canadian province of Quebec, ... A, Perie S, Pouget J, Eymard B; Neurologists of French Neuromuscular Reference Centers CORNEMUS and FILNEMUS. Correlation between ...
Core References in Introductory Social Psychology and Developmental Psychology Textbooks
ERIC Educational Resources Information Center
Whitehead, George I., III; Smith, Stephanie H.; Losonczy-Marshall, Marta
2017-01-01
The purpose of the present study was to identify the core references in introductory textbooks in two sub-disciplines of psychology: social psychology and developmental psychology. One research question was the extent to which the common references in these textbooks present the trends in contemporary research in each sub-discipline. An analysis…
75 FR 45583 - New York: Incorporation by Reference of State Hazardous Waste Management Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
... authorized and that EPA will enforce under the Solid Waste Disposal Act, as amended and commonly referred to...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... authorized hazardous waste program which is set forth in the regulations entitled ``Approved State Hazardous...
fMRI Evidence for Strategic Decision-Making during Resolution of Pronoun Reference
ERIC Educational Resources Information Center
McMillan, Corey T.; Clark, Robin; Gunawardena, Delani; Ryant, Neville; Grossman, Murray
2012-01-01
Pronouns are extraordinarily common in daily language yet little is known about the neural mechanisms that support decisions about pronoun reference. We propose a large-scale neural network for resolving pronoun reference that consists of two components. First, a core language network in peri-Sylvian cortex supports syntactic and semantic…
Validation of reference genes for gene expression studies in soybean aphid, Aphis glycines Matsumura
USDA-ARS?s Scientific Manuscript database
Quantitative real-time PCR (qRT-PCR) is a common tool for quantifying mRNA transcripts. To normalize results, a reference gene is mandatory. Aphis glycines is a significant soybean pest, yet gene expression and functional genomics studies are hindered by a lack of stable reference genes. We evalu...
The Role of Metarepresentation in the Production and Resolution of Referring Expressions.
Horton, William S; Brennan, Susan E
2016-01-01
In this paper we consider the potential role of metarepresentation-the representation of another representation, or as commonly considered within cognitive science, the mental representation of another individual's knowledge and beliefs-in mediating definite reference and common ground in conversation. Using dialogues from a referential communication study in which speakers conversed in succession with two different addressees, we highlight ways in which interlocutors work together to successfully refer to objects, and achieve shared conceptualizations. We briefly review accounts of how such shared conceptualizations could be represented in memory, from simple associations between label and referent, to "triple co-presence" representations that track interlocutors in an episode of referring, to more elaborate metarepresentations that invoke theory of mind, mutual knowledge, or a model of a conversational partner. We consider how some forms of metarepresentation, once created and activated, could account for definite reference in conversation by appealing to ordinary processes in memory. We conclude that any representations that capture information about others' perspectives are likely to be relatively simple and subject to the same kinds of constraints on attention and memory that influence other kinds of cognitive representations.
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
Development of dual PZT transducers for reference-free crack detection in thin plate structures.
Sohn, Hoon; Kim, Seuno Bum
2010-01-01
A new Lamb-wave-based nondestructive testing (NDT) technique, which does not rely on previously stored baseline data, is developed for crack monitoring in plate structures. Commonly, the presence of damage is identified by comparing "current data" measured from a potentially damaged stage of a structure with "baseline data" previously obtained at the intact condition of the structure. In practice, structural defects typically take place long after collection of the baseline data, and the baseline data can be also affected by external loading, temperature variations, and changing boundary conditions. To eliminate the dependence on the baseline data comparison, the authors previously developed a reference-free NDT technique using 2 pairs of collocated lead zirconate titanate (PZT) transducers placed on both sides of a plate. This reference-free technique is further advanced in the present study by the necessity of attaching transducers only on a single surface of a structure for certain applications such as aircraft. To achieve this goal, a new design of PZT transducers called dual PZT transducers is proposed. Crack formation creates Lamb wave mode conversion due to a sudden thickness change of the structure. This crack appearance is instantly detected from the measured Lamb wave signals using the dual PZT transducers. This study also suggests a reference-free statistical approach that enables damage classification using only the currently measured data set. Numerical simulations and experiments were conducted using an aluminum plate with uniform thickness and fundamental Lamb waves modes to demonstrate the applicability of the proposed technique to reference-free crack detection.
Robust low-frequency spread-spectrum navigation system
Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN
2012-01-03
Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.
Robust low-frequency spread-spectrum navigation system
Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN
2011-01-25
Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.
Robust low-frequency spread-spectrum navigation system
Smith, Stephen F; Moore, James A
2012-10-30
Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.
Robust low-frequency spread-spectrum navigation system
Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN
2009-12-01
Methods and apparatus are described for a navigation system. A process includes providing a plurality of transmitters distributed throughout a desired coverage area; locking the plurality of transmitters to a common timing reference; transmitting a signal from each of the plurality of transmitters. An apparatus includes a plurality of transmitters distributed throughout a desired coverage area; wherein each of the plurality of transmitters comprises a packet generator; and wherein the plurality of transmitters are locked to a common timing reference.
ERIC Educational Resources Information Center
Tannenbaum, Richard J.; Wylie, E. Caroline
2008-01-01
The Common European Framework of Reference (CEFR) describes language proficiency in reading, writing, speaking, and listening on a 6-level scale. In this study, English-language experts from across Europe linked CEFR levels to scores on three tests: the TOEFL® iBT test, the TOEIC® assessment, and the TOEIC "Bridge"™ test.…
ERIC Educational Resources Information Center
Little, David
2013-01-01
This article is based on a plenary talk given at the CercleS seminar hosted by the University of Groningen in November 2011 to mark the tenth anniversary of the publication of the "Common European Framework of Reference for Languages" and the launch of the European Language Portfolio. The first part of the article summarizes the history…
Data discovery and data processing for environmental research infrastructures
NASA Astrophysics Data System (ADS)
Los, Wouter; Beranzoli, Laura; Corriero, Giuseppe; Cossu, Roberto; Fiore, Nicola; Hardisty, Alex; Legré, Yannick; Pagano, Pasquale; Puglisi, Giuseppe; Sorvari, Sanna; Turunen, Esa
2013-04-01
The European ENVRI project (Common operations of Environmental Research Infrastructures) is addressing common ICT solutions for the research infrastructures as selected in the ESFRI Roadmap. More specifically, the project is looking for solutions that will assist interdisciplinary users who want to benefit from the data and other services of more than a single research infrastructure. However, the infrastructure architectures, the data, data formats, scales and granularity are very different. Indeed, they deal with diverse scientific disciplines, from plate tectonics, the deep sea, sea and land surface up to atmosphere and troposphere, from the dead to the living environment, and with a variety of instruments producing increasingly larger amounts of data. One of the approaches in the ENVRI project is to design a common Reference Model that will serve to promote infrastructure interoperability at the data, technical and service levels. The analysis of the characteristics of the environmental research infrastructures assisted in developing the Reference Model, and which is also an example for comparable infrastructures worldwide. Still, it is for users already now important to have the facilities available for multi-disciplinary data discovery and data processing. The rise of systems research, addressing Earth as a single complex and coupled system is requiring such capabilities. So, another approach in the project is to adapt existing ICT solutions to short term applications. This is being tested for a few study cases. One of these is looking for possible coupled processes following a volcano eruption in the vertical column from deep sea to troposphere. Another one deals with volcano either human impacts on atmospheric and sea CO2 pressure and the implications for sea acidification and marine biodiversity and their ecosystems. And a third one deals with the variety of sensor and satellites data sensing the area around a volcano cone. Preliminary results on these studies will be reported. The common results will assist in shaping more generic solutions to be adopted by the appropriate research infrastructures.
2012-01-01
Background General practitioners (GPs) play a key role in assessing and managing adult mental health problems, but this input is not seen in their management of child and adolescent mental health. Mental health problems in 5–19-year-olds are common, yet detection rates in primary care are low. The symptoms of most adult diagnoses of mental health problems are present by mid-adolescence, yet the typical time from onset to diagnosis is 5–15 years. The role of general practice in this area has been underexplored. Aim This pilot study explores the potential of GPs to respond to common mental health problems in children and adolescents. Design Children and young people who would have ordinarily been referred to Child and Adolescent Mental Health Services (CAMHS) were seen in a GP setting. In a UK general practice surgery serving a disadvantaged population. Method Children and young people were seen for an initial biopsychosocial assessment and formulation of the presenting concerns. GP-based interventions were offered as appropriate or referred to CAMHS. Results Data from the first 50 children (2–19 years) are presented. Twenty younger children (10 years and under) and 30 older children (11 years and above) were seen. Eighteen referrals were made to CAMHS. GP interventions included watchful waiting, brief behavioural interventions, non-directive counselling, brief cognitive– behavioural therapy (CBT) and liaison with colleagues in education, CAMHS and the voluntary sector. Conclusion This clinical pilot demonstrates that with adequate time, access to supervision and practice support, children and young people experiencing emotional and behavioural problems associated with common mental health issues can be helped in primary care. PMID:23730336
Ganger, Michael T; Dietz, Geoffrey D; Ewing, Sarah J
2017-12-01
qPCR has established itself as the technique of choice for the quantification of gene expression. Procedures for conducting qPCR have received significant attention; however, more rigorous approaches to the statistical analysis of qPCR data are needed. Here we develop a mathematical model, termed the Common Base Method, for analysis of qPCR data based on threshold cycle values (C q ) and efficiencies of reactions (E). The Common Base Method keeps all calculations in the logscale as long as possible by working with log 10 (E) ∙ C q , which we call the efficiency-weighted C q value; subsequent statistical analyses are then applied in the logscale. We show how efficiency-weighted C q values may be analyzed using a simple paired or unpaired experimental design and develop blocking methods to help reduce unexplained variation. The Common Base Method has several advantages. It allows for the incorporation of well-specific efficiencies and multiple reference genes. The method does not necessitate the pairing of samples that must be performed using traditional analysis methods in order to calculate relative expression ratios. Our method is also simple enough to be implemented in any spreadsheet or statistical software without additional scripts or proprietary components.
Genetic basis of hearing loss in Spanish, Hispanic and Latino populations.
Mittal, Rahul; Patel, Amit P; Nguyen, Desiree; Pan, Debbie R; Jhaveri, Vasanti M; Rudman, Jason R; Dharmaraja, Arjuna; Yan, Denise; Feng, Yong; Chapagain, Prem; Lee, David J; Blanton, Susan H; Liu, Xue Zhong
2018-03-20
Hearing loss (HL) is the most common neurosensory disorder affecting humans. The screening, prevention and treatment of HL require a better understanding of the underlying molecular mechanisms. Genetic predisposition is one of the most common factors that leads to HL. Most HL studies include few Spanish, Hispanic and Latino participants, leaving a critical gap in our understanding about the prevalence, impact, unmet health care needs, and genetic factors associated with hearing impairment among Spanish, Hispanic and Latino populations. The few studies which have been performed show that the gene variants commonly associated with HL in non-Spanish and non-Hispanic populations are infrequently responsible for hearing impairment in Spanish as well as Hispanic and Latino populations (hereafter referred to as Hispanic). To design effective screening tools to detect HL in Spanish and Hispanic populations, studies must be conducted to determine the gene variants that are most commonly associated with hearing impairment in this racial/ethnic group. In this review article, we summarize gene variants and loci associated with HL in Spanish and Hispanic populations. Identifying new genetic variants associated with HL in Spanish and Hispanic populations will pave the way to develop effective screening tools and therapeutic strategies for HL. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhu, Wuzheng; Lin, Yaqiu; Liao, Honghai; Wang, Yong
2015-01-01
The identification of suitable reference genes is critical for obtaining reliable results from gene expression studies using quantitative real-time PCR (qPCR) because the expression of reference genes may vary considerably under different experimental conditions. In most cases, however, commonly used reference genes are employed in data normalization without proper validation, which may lead to incorrect data interpretation. Here, we aim to select a set of optimal reference genes for the accurate normalization of gene expression associated with intramuscular fat (IMF) deposition during development. In the present study, eight reference genes (PPIB, HMBS, RPLP0, B2M, YWHAZ, 18S, GAPDH and ACTB) were evaluated by three different algorithms (geNorm, NormFinder and BestKeeper) in two types of muscle tissues (longissimus dorsi muscle and biceps femoris muscle) across different developmental stages. All three algorithms gave similar results. PPIB and HMBS were identified as the most stable reference genes, while the commonly used reference genes 18S and GAPDH were the most variably expressed, with expression varying dramatically across different developmental stages. Furthermore, to reveal the crucial role of appropriate reference genes in obtaining a reliable result, analysis of PPARG expression was performed by normalization to the most and the least stable reference genes. The relative expression levels of PPARG normalized to the most stable reference genes greatly differed from those normalized to the least stable one. Therefore, evaluation of reference genes must be performed for a given experimental condition before the reference genes are used. PPIB and HMBS are the optimal reference genes for analysis of gene expression associated with IMF deposition in skeletal muscle during development.
Trongnetrpunya, Amy; Nandi, Bijurika; Kang, Daesung; Kocsis, Bernat; Schroeder, Charles E; Ding, Mingzhou
2015-01-01
Multielectrode voltage data are usually recorded against a common reference. Such data are frequently used without further treatment to assess patterns of functional connectivity between neuronal populations and between brain areas. It is important to note from the outset that such an approach is valid only when the reference electrode is nearly electrically silent. In practice, however, the reference electrode is generally not electrically silent, thereby adding a common signal to the recorded data. Volume conduction further complicates the problem. In this study we demonstrate the adverse effects of common signals on the estimation of Granger causality, which is a statistical measure used to infer synaptic transmission and information flow in neural circuits from multielectrode data. We further test the hypothesis that the problem can be overcome by utilizing bipolar derivations where the difference between two nearby electrodes is taken and treated as a representation of local neural activity. Simulated data generated by a neuronal network model where the connectivity pattern is known were considered first. This was followed by analyzing data from three experimental preparations where a priori predictions regarding the patterns of causal interactions can be made: (1) laminar recordings from the hippocampus of an anesthetized rat during theta rhythm, (2) laminar recordings from V4 of an awake-behaving macaque monkey during alpha rhythm, and (3) ECoG recordings from electrode arrays implanted in the middle temporal lobe and prefrontal cortex of an epilepsy patient during fixation. For both simulation and experimental analysis the results show that bipolar derivations yield the expected connectivity patterns whereas the untreated data (referred to as unipolar signals) do not. In addition, current source density signals, where applicable, yield results that are close to the expected connectivity patterns, whereas the commonly practiced average re-reference method leads to erroneous results.
Reference Equations for Static Lung Volumes and TLCO from a Population Sample in Northern Greece.
Michailopoulos, Pavlos; Kontakiotis, Theodoros; Spyratos, Dionisios; Argyropoulou-Pataka, Paraskevi; Sichletidis, Lazaros
2015-02-14
Background: The most commonly used reference equations for the measurement of static lung volumes/capacities and transfer factor of the lung for CO (TL CO ) are based on studies around 30-40 years old with significant limitations. Objectives: Our aim was to (1) develop reference equations for static lung volumes and TL CO using the current American Thoracic Society/European Respiratory Society guidelines, and (2) compare the equations derived with those most commonly used. Methods: Healthy Caucasian subjects (234 males and 233 females) aged 18-91 years were recruited. All of them were healthy never smokers with a normal chest X-ray. Static lung volumes and TL CO were measured with a single-breath technique according to the latest guidelines. Results: Curvilinear regression prediction equations derived from the present study were compared with those that are most commonly used. Our reference equations in accordance with the latest studies show lower values for all static lung volume parameters and TL CO as well as a different way of deviation of those parameters (i.e. declining with age total lung capacity, TL CO age decline in both sex and functional residual capacity age rise in males). Conclusions: We suggest that old reference values of static lung volumes and TL CO should be updated, and our perception of deviation of some spirometric parameters should be revised. Our new reference curvilinear equations derived according to the latest guidelines could contribute to the updating by respiratory societies of old existing reference values and result in a better estimation of the lung function of contemporary populations with similar Caucasian characteristics. © 2015 S. Karger AG, Basel.
TMN: Introduction and interpretation
NASA Astrophysics Data System (ADS)
Pras, Aiko
An overview of Telecommunications Management Network (TMN) status is presented. Its relation with Open System Interconnection (OSI) systems management is given and the commonalities and distinctions are identified. Those aspects that distinguish TMN from OSI management are introduced; TMN's functional and physical architectures and TMN's logical layered architecture are discussed. An analysis of the concepts used by these architectures (reference point, interface, function block, and building block) is given. The use of these concepts to express geographical distribution and functional layering is investigated. This aspect is interesting to understand how OSI management protocols can be used in a TMN environment. A statement regarding applicability of TMN as a model that helps the designers of (management) networks is given.
Tellinghuisen, Joel
2016-03-01
Relative expression ratios are commonly estimated in real-time qPCR studies by comparing the quantification cycle for the target gene with that for a reference gene in the treatment samples, normalized to the same quantities determined for a control sample. For the "standard curve" design, where data are obtained for all four of these at several dilutions, nonlinear least squares can be used to assess the amplification efficiencies (AE) and the adjusted ΔΔCq and its uncertainty, with automatic inclusion of the effect of uncertainty in the AEs. An algorithm is illustrated for the KaleidaGraph program. Copyright © 2015 Elsevier Inc. All rights reserved.
Stabley, Deborah L; Holbrook, Jennifer; Harris, Ashlee W; Swoboda, Kathryn J; Crawford, Thomas O; Sol-Church, Katia; Butchbach, Matthew E R
2017-05-01
Fibroblasts and lymphoblastoid cell lines (LCLs) derived from individuals with spinal muscular atrophy (SMA) have been and continue to be essential for translational SMA research. Authentication of cell lines helps ensure reproducibility and rigor in biomedical research. This quality control measure identifies mislabeling or cross-contamination of cell lines and prevents misinterpretation of data. Unfortunately, authentication of SMA cell lines used in various studies has not been possible because of a lack of a reference. In this study, we provide said reference so that SMA cell lines can be subsequently authenticated. We use short tandem repeat (STR) profiling and digital PCR (dPCR), which quantifies SMN1 and SMN2 copy numbers, to generate molecular identity codes for fibroblasts and LCLs that are commonly used in SMA research. Using these molecular identity codes, we clarify the familial relationships within a set of fibroblasts commonly used in SMA research. This study presents the first cell line reference set for the SMA research community and demonstrates its usefulness for re-identification and authentication of lines commonly used as in vitro models for future studies. Copyright © 2017 Elsevier B.V. All rights reserved.
[Saarland Growth Study: sampling design].
Danker-Hopfe, H; Zabransky, S
2000-01-01
The use of reference data to evaluate the physical development of children and adolescents is part of the daily routine in the paediatric ambulance. The construction of such reference data is based on the collection of extensive reference data. There are different kinds of reference data: cross sectional references, which are based on data collected from a big representative cross-sectional sample of the population, longitudinal references, which are based on follow-up surveys of usually smaller samples of individuals from birth to maturity, and mixed longitudinal references, which are a combination of longitudinal and cross-sectional reference data. The advantages and disadvantages of the different methods of data collection and the resulting reference data are discussed. The Saarland Growth Study was conducted for several reasons: growth processes are subject to secular changes, there are no specific reference data for children and adolescents from this part of the country and the growth charts in use in the paediatric praxis are possibly not appropriate any more. Therefore, the Saarland Growth Study served two purposes a) to create actual regional reference data and b) to create a database for future studies on secular trends in growth processes of children and adolescents from Saarland. The present contribution focusses on general remarks on the sampling design of (cross-sectional) growth surveys and its inferences for the design of the present study.
Development of internal forest soil reference samples and testing of digestion methods
J.E. Hislop; J.W. Hornbeck; S.W. Bailey; R.A. Hallett
1998-01-01
Our research requires determinations of total elemental concentrations of forest soils. The lack of certified forest soil reference materials led us to develop internal reference samples. Samples were collected from three soil horizons (Oa, B, and C) at three locations having forested, acidic soils similar to those we commonly analyze. A shatterbox was used to...
Free-free and fixed base modal survey tests of the Space Station Common Module Prototype
NASA Technical Reports Server (NTRS)
Driskill, T. C.; Anderson, J. B.; Coleman, A. D.
1992-01-01
This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.
Asbestos: Geology, Mineralogy, Mining, and Uses
Virta, Robert L.
2002-01-01
The term asbestos is a generic designation referring usually to six types of naturally occurring mineral fibers that are or have been commercially exploited. These fibers belong to two mineral groups: serpentines and amphiboles. The serpentine group contains a single asbestiform variety: chrysotile; five asbestiform varieties of amphiboles are known: anthophyllite asbestos, grunerite asbestos (amosite), riebeckite asbestos (crocidolite), tremolite asbestos, and actinolite asbestos. These fibrous minerals share several properties which qualify them as asbestiform fibers: they are found in bundles of fibers which can be easily separated from the host matrix or cleaved into thinner fibers; the fibers exhibit high tensile strengths, they show high length: diameter (aspect) ratios, from a minimum of 20 up to greater than 1000; they are sufficiently flexible to be spun; and macroscopically, they resemble organic fibers such as cellulose. Since asbestos fibers are all silicates, they exhibit several other common properties, such as incombustibility, thermal stability, resistance to biodegradation, chemical inertia toward most chemicals, and low electrical conductivity. The term asbestos has traditionally been attributed only to those varieties that are commercially exploited. The industrial applications of asbestos fibers have now shifted almost exclusively to chrysotile. Two types of amphiboles, commonly designated as amosite and crocidolite are no longer mined. The other three amphibole varieties, anthophyllite asbestos, actinolite asbestos, and tremolite asbestos, have no significant industrial applications presently.
A low-drift, low-noise, multichannel dc voltage source for segmented-electrode Paul traps
NASA Astrophysics Data System (ADS)
Beev, Nikolai; Fenske, Julia-Aileen; Hannig, Stephan; Schmidt, Piet O.
2017-05-01
We present the design, construction, and characterization of a multichannel, low-drift, low-noise dc voltage source specially designed for biasing the electrodes of segmented linear Paul traps. The system produces 20 output voltage pairs having a common-mode range of 0 to +120 V with 3.7 mV/LSB (least significant bit) resolution and differential ranges of ±5 V with 150 μV/LSB or ±16 V with 610 μV/LSB resolution. All common-mode and differential voltages are independently controllable, and all pairs share the same ground reference. The measured drift of the voltages after warm-up is lower than 1 LSB peak-to-peak on the time scale of 2 h. The noise of an output voltage measured with respect to ground is <10 μVRMS within 10 Hz-100 kHz, with spectral density lower than 3 nV Hz-1/2 above 50 kHz. The performance of the system is limited by the external commercial multichannel DAC unit NI 9264, and in principle, it is possible to achieve higher stability and lower noise with the same voltage ranges. The system has a compact, modular, and scalable architecture, having all parts except for the DAC chassis housed within a single 19″ 3HE rack.
Screen-printed back-to-back electroanalytical sensors.
Metters, Jonathan P; Randviir, Edward P; Banks, Craig E
2014-11-07
We introduce the concept of screen-printed back-to-back electroanalytical sensors where in this facile and generic approach, screen-printed electrodes are printed back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor would be. This approach utilises the usually redundant back of the screen-printed sensor, converting this "dead-space" into a further electrochemical sensor which results in improvements in the analytical performance. In the use of the back-to-back design, the electrode area is consequently doubled with improvements in the analytical performance observed with the analytical sensitivity (gradient of a plot of peak height/analytical signal against concentration) doubling and the corresponding limit-of-detection being reduced. We also demonstrate that through intelligent electrode design, a quadruple in the observed analytical sensitivity can also be realised when double microband electrodes are used in the back-to-back configuration as long as they are placed sufficiently apart such that no diffusional interaction occurs. Such work is generic in nature and can be facilely applied to a plethora of screen-printed (and related) sensors utilising the commonly overlooked redundant back of the electrode providing facile improvements in the electroanalytical performance.
1992-07-01
be used effectively in new construction or retrofit applications. These systems usually contain: 1. Molded expanded polystyrene insulation board (MEPS...commonly referred to as "bead board," or extruded expanded polystyrene insulation board (XEPS), commonly referred to as "blue board." 2. An...Walls ( Expanded Polystyrene Insulation Faced with a Thin Rendering), M.O.A.T. n 22, June 1988. 7 ASTM D3029-90. "Standard Test Methods for Impact
NASA Astrophysics Data System (ADS)
Junqueira Leão, Rodrigo; Raffaelo Baldo, Crhistian; Collucci da Costa Reis, Maria Luisa; Alves Trabanco, Jorge Luiz
2018-03-01
The building blocks of particle accelerators are magnets responsible for keeping beams of charged particles at a desired trajectory. Magnets are commonly grouped in support structures named girders, which are mounted on vertical and horizontal stages. The performance of this type of machine is highly dependent on the relative alignment between its main components. The length of particle accelerators ranges from small machines to large-scale national or international facilities, with typical lengths of hundreds of meters to a few kilometers. This relatively large volume together with micrometric positioning tolerances make the alignment activity a classical large-scale dimensional metrology problem. The alignment concept relies on networks of fixed monuments installed on the building structure to which all accelerator components are referred. In this work, the Sirius accelerator is taken as a case study, and an alignment network is optimized via computational methods in terms of geometry, densification, and surveying procedure. Laser trackers are employed to guide the installation and measure the girders’ positions, using the optimized network as a reference and applying the metric developed in part I of this paper. Simulations demonstrate the feasibility of aligning the 220 girders of the Sirius synchrotron to better than 0.080 mm, at a coverage probability of 95%.
Linder, Suzanne K.; Kamath, Geetanjali R.; Pratt, Gregory F.; Saraykar, Smita S.; Volk, Robert J.
2015-01-01
Objective To compare the effectiveness of two search methods in identifying studies that used the Control Preferences Scale (CPS), a healthcare decision-making instrument commonly used in clinical settings. Study Design & Setting We searched the literature using two methods: 1) keyword searching using variations of “control preferences scale” and 2) cited reference searching using two seminal CPS publications. We searched three bibliographic databases [PubMed, Scopus, Web of Science (WOS)] and one full-text database (Google Scholar). We report precision and sensitivity as measures of effectiveness. Results Keyword searches in bibliographic databases yielded high average precision (90%), but low average sensitivity (16%). PubMed was the most precise, followed closely by Scopus and WOS. The Google Scholar keyword search had low precision (54%) but provided the highest sensitivity (70%). Cited reference searches in all databases yielded moderate sensitivity (45–54%), but precision ranged from 35–75% with Scopus being the most precise. Conclusion Cited reference searches were more sensitive than keyword searches, making it a more comprehensive strategy to identify all studies that use a particular instrument. Keyword searches provide a quick way of finding some but not all relevant articles. Goals, time and resources should dictate the combination of which methods and databases are used. PMID:25554521
A Multi-Channel, Flex-Rigid ECoG Microelectrode Array for Visual Cortical Interfacing
Tolstosheeva, Elena; Gordillo-González, Víctor; Biefeld, Volker; Kempen, Ludger; Mandon, Sunita; Kreiter, Andreas K.; Lang, Walter
2015-01-01
High-density electrocortical (ECoG) microelectrode arrays are promising signal-acquisition platforms for brain-computer interfaces envisioned, e.g., as high-performance communication solutions for paralyzed persons. We propose a multi-channel microelectrode array capable of recording ECoG field potentials with high spatial resolution. The proposed array is of a 150 mm2 total recording area; it has 124 circular electrodes (100, 300 and 500 μm in diameter) situated on the edges of concentric hexagons (min. 0.8 mm interdistance) and a skull-facing reference electrode (2.5 mm2 surface area). The array is processed as a free-standing device to enable monolithic integration of a rigid interposer, designed for soldering of fine-pitch SMD-connectors on a minimal assembly area. Electrochemical characterization revealed distinct impedance spectral bands for the 100, 300 and 500 μm-type electrodes, and for the array's own reference. Epidural recordings from the primary visual cortex (V1) of an awake Rhesus macaque showed natural electrophysiological signals and clear responses to standard visual stimulation. The ECoG electrodes of larger surface area recorded signals with greater spectral power in the gamma band, while the skull-facing reference electrode provided higher average gamma power spectral density (γPSD) than the common average referencing technique. PMID:25569757
Llano Lopez, L; Hauser, J; Feldon, J; Gargiulo, P A; Yee, B K
2010-05-01
The Morris water maze (WM) is a common spatial memory test in rats. It has been adapted for evaluating genetic manipulations in mice. One major acknowledged problem of this cross-species translation is floating. We investigated here in mice the feasibility and practicality of an alternative paradigm-the cheeseboard (CB), which is a dry version of the WM, in a within-subject design allowing direct comparison with the conventional WM. Under identical task demands (reference or working memory), mice learned in the CB as efficiently as in the WM. Furthermore, individual differences in learning rate correlated between the two reference memory tests conducted separately in the two mazes. However, no such correlation was found with respect to reference memory retention or working memory performance. This study demonstrated that the CB is an effective alternative to the WM as spatial cognition test. Additional tests in the CB confirmed that the mice relied on extra maze cues in their spatial search. We would recommend the CB as a valuable addition to, rather than a replacement of the WM in phenotyping transgenic mice, because the two apparatus might diverge in the ability to detect individual differences in various domains of mnemonic functions.
Zhang, Hui; Cowling, David W; Facer, Matthew
2017-12-01
Various health insurance benefit designs based on value-based purchasing have been promoted to steer patients to high-value providers, but little is known about the designs' relative effectiveness and underlying mechanisms. We compared the impact of two designs implemented by the California Public Employees' Retirement System on inpatient hospital total hip or knee replacement: a reference-based pricing design for preferred provider organizations (PPOs) and a centers-of-excellence design for health maintenance organizations (HMOs). Payment and utilization data for the procedures in the period 2008-13 were evaluated using pre-post and quasi-experimental designs at the system and health plan levels, adjusting for demographic characteristics, case-mix, and other confounders. We found that both designs prompted higher use of designated low-price high-quality facilities and reduced average replacement expenses per member at the plan and system levels. However, the designs used different routes: The reference-based pricing design reduced average replacement payments per case in PPOs by 26.7 percent in the first year, compared to HMOs, but did not lower PPO members' utilization rates. In contrast, the centers-of-excellence design lowered HMO members' utilization rates by 29.2 percent in the first year, compared to PPOs, but did not reduce HMO average replacement payments per case. The reference-based pricing design appears more suitable for reducing price variation, and the centers-of-excellence design for addressing variation in use.
PhosSA: Fast and accurate phosphorylation site assignment algorithm for mass spectrometry data.
Saeed, Fahad; Pisitkun, Trairak; Hoffert, Jason D; Rashidian, Sara; Wang, Guanghui; Gucek, Marjan; Knepper, Mark A
2013-11-07
Phosphorylation site assignment of high throughput tandem mass spectrometry (LC-MS/MS) data is one of the most common and critical aspects of phosphoproteomics. Correctly assigning phosphorylated residues helps us understand their biological significance. The design of common search algorithms (such as Sequest, Mascot etc.) do not incorporate site assignment; therefore additional algorithms are essential to assign phosphorylation sites for mass spectrometry data. The main contribution of this study is the design and implementation of a linear time and space dynamic programming strategy for phosphorylation site assignment referred to as PhosSA. The proposed algorithm uses summation of peak intensities associated with theoretical spectra as an objective function. Quality control of the assigned sites is achieved using a post-processing redundancy criteria that indicates the signal-to-noise ratio properties of the fragmented spectra. The quality assessment of the algorithm was determined using experimentally generated data sets using synthetic peptides for which phosphorylation sites were known. We report that PhosSA was able to achieve a high degree of accuracy and sensitivity with all the experimentally generated mass spectrometry data sets. The implemented algorithm is shown to be extremely fast and scalable with increasing number of spectra (we report up to 0.5 million spectra/hour on a moderate workstation). The algorithm is designed to accept results from both Sequest and Mascot search engines. An executable is freely available at http://helixweb.nih.gov/ESBL/PhosSA/ for academic research purposes.
Mithal, Leena B; Patel, Payal S; Mithal, Divakar; Palac, Hannah L; Rozenfeld, Michael N
2017-05-01
Numerous recent articles have reported brain gadolinium deposition when using linear but not macrocyclic gadolinium-based contrast agents (GBCAs). To determine the current landscape of gadolinium use among pediatric institutions and the knowledge base of radiologists and referring providers with regard to GBCAs and brain gadolinium deposition. We e-mailed voluntary closed surveys to 5,390 physicians in various pediatric professional societies between January 2016 and March 2016. We used chi-square and Fisher exact tests to compare response distributions among specialties. We found that 80% of surveyed pediatric hospitals use macrocyclic contrast agents. In the last year, 58% switched their agent, most commonly to gadoterate meglumine, with the most common reason being brain gadolinium deposition. Furthermore, surveys indicated that 23% of hospitals are considering switching, and, of these, 83% would switch to gadoterate meglumine; the most common reasons were brain gadolinium deposition and safety. Radiologists were more aware of brain gadolinium deposition than non-radiologist physicians (87% vs. 26%; P<0.0001). Radiologists and referring providers expressed similar levels of concern (95% and 89%). Twelve percent of radiologists and 2% of referring providers reported patients asking about brain gadolinium deposition. Radiologists were significantly more comfortable addressing patient inquiries than referring pediatric physicians (48% vs. 6%; P<0.0001). The number of MRIs requested by referring pediatric physicians correlated with their knowledge of brain gadolinium deposition, contrast agent used by their hospital, and comfort discussing brain gadolinium deposition with patients (P<0.0001). Since the discovery of brain gadolinium deposition, many pediatric hospitals have switched to or plan to switch to a more stable macrocyclic MR contrast agent, most commonly gadoterate meglumine. Despite this, there is need for substantial further education of radiologists and referring pediatric providers regarding GBCAs and brain gadolinium deposition.
It’s about This and That: A Description of Anaphoric Expressions in Clinical Text
Wang, Yan; Melton, Genevieve B.; Pakhomov, Serguei
2011-01-01
Although anaphoric expressions are very common in biomedical and clinical documents, little work has been done to systematically characterize their use in clinical text. Samples of ‘it’, ‘this’, and ‘that’ expressions occurring in inpatient clinical notes from four metropolitan hospitals were analyzed using a combination of semi-automated and manual annotation techniques. We developed a rule-based approach to filter potential non-referential expressions. A physician then manually annotated 1000 potential referential instances to determine referent status and the antecedent of each referent expression. A distributional analysis of the three referring expressions in the entire corpus of notes demonstrates a high prevalence of anaphora and large variance in distributions of referential expressions with different notes. Our results confirm that anaphoric expressions are common in clinical texts. Effective co-reference resolution with anaphoric expressions remains an important challenge in medical natural language processing research. PMID:22195211
Monolithic focused reference beam X-ray holography
Geilhufe, J.; Pfau, B.; Schneider, M.; Büttner, F.; Günther, C. M.; Werner, S.; Schaffert, S.; Guehrs, E.; Frömmel, S.; Kläui, M.; Eisebitt, S.
2014-01-01
Fourier transform holography is a highly efficient and robust imaging method, suitable for single-shot imaging at coherent X-ray sources. In its common implementation, the image contrast is limited by the reference signal generated by a small pinhole aperture. Increased pinhole diameters improve the signal, whereas the resolution is diminished. Here we report a new concept to decouple the spatial resolution from the image contrast by employing a Fresnel zone plate to provide the reference beam. Superimposed on-axis images of distinct foci are separated with a novel algorithm. Our method is insensitive to mechanical drift or vibrations and allows for long integration times common at low-flux facilities like high harmonic generation sources. The application of monolithic focused reference beams improves the efficiency of high-resolution X-ray Fourier transform holography beyond all present approaches and paves the path towards sub-10 nm single-shot X-ray imaging. PMID:24394675
Pentaplex PCR as screening assay for jellyfish species identification in food products.
Armani, Andrea; Giusti, Alice; Castigliego, Lorenzo; Rossi, Aurelio; Tinacci, Lara; Gianfaldoni, Daniela; Guidi, Alessandra
2014-12-17
Salted jellyfish, a traditional food in Asian Countries, is nowadays spreading on the Western markets. In this work, we developed a Pentaplex PCR for the identification of five edible species (Nemopilema nomurai, Rhopilema esculentum, Rhizostoma pulmo, Pelagia noctiluca, and Cotylorhiza tuberculata), which cannot be identified by a mere visual inspection in jellyfish products sold as food. A common degenerated forward primer and five specie-specific reverse primers were designed to amplify COI gene regions of different lengths. Another primer pair targeted the 28SrRNA gene and was intended as common positive reaction control. Considering the high level of degradation in the DNA extracted from acidified and salted products, the maximum length of the amplicons was set at 200 bp. The PCR was developed using 66 reference DNA samples. It gave successful amplifications in 85.4% of 48 ready to eat products (REs) and in 60% of 30 classical salted products (CPs) collected on the market.
VizieR Online Data Catalog: PMA Catalogue (Akhmetov+, 2017)
NASA Astrophysics Data System (ADS)
Akhmetov, V. S.; Fedorov, P. N.; Velichko, A. B.; Shulga, V. M.
2017-06-01
The idea for creating the catalogue is very simple. The PMA catalogue has been derived from a combination of two catalogues, namely 2MASS and Gaia DR1. The difference of epochs of observations for these catalogues is approximately 15 yr. The positions of objects in the Gaia DR1 catalogue are referred to the reference frame, which is consistent with ICRF to better than 0.1 mas for the J2015.0 epoch. The positions of objects in 2MASS are referred to HCRF, which, as was shown in Kovalevsky et al. (1997A&A...323..620K), is aligned with the ICRF to within ±0.6 mas at the epoch 1991.25 and is non-rotating with respect to distant extragalactic objects to within ±0.25mas/yr. By comparing the positions of the common objects contained in the catalogues, it is possible to determine their proper motions within their common range of stellar magnitudes by dividing differences of positions over the time interval between their observations. Formally, proper motions derived in such a way are given in the ICRF system, because the positions of both Gaia DR1 stars and those of 2MASS objects (through Hipparcos/Tycho-2 stars) are given in the ICRF and cover the whole sphere without gaps. We designate them further in this paper as relative, with the aim of discriminating them from absolute ones, which refer to the reference frame defined by the positions of about 1.6 million galaxies from Gaia DR1. There is no possibility of obtaining estimates of individual errors of proper motions of stars for the PMA Catalogue from the intrinsic convergence, because the direct errors for positions are not indicated in 2MASS. Therefore we use some indirect methods to obtain the estimates of uncertainties for proper motions. After elimination of the systematic errors, the root-mean-squared deviation of the coordinate differences of extended sources is about 200mas, and the mean number of galaxies inside each pixel is about 1300, so we expect the error of the absolute calibration to be 0.35mas/yr. We compared the proper motions of common objects from PMA and from the TGAS and UCAC4 catalogues. Knowing the mean-square errors of (PMA-TGAS) and (PMA-UCAC4) proper motion differences in each pixel, the appropriate errors in PMA vary from 2 to 10mas/yr, depending on magnitude, which are consistent with the errors calculated above. In case of any problems or questions, please contact by e-mail V.S. Akhmetov (akhmetovvs(at)gmail.com or akhmetov(at)astron.kharkov.ua). (1 data file).
Portrayal of alcohol intoxication on YouTube.
Primack, Brian A; Colditz, Jason B; Pang, Kevin C; Jackson, Kristina M
2015-03-01
We aimed to characterize the content of leading YouTube videos related to alcohol intoxication and to examine factors associated with alcohol intoxication in videos that were assessed positively by viewers. We systematically captured the 70 most relevant and popular videos on YouTube related to alcohol intoxication. We employed an iterative process to codebook development which resulted in 42 codes in 6 categories: video characteristics, character socio demographics, alcohol depiction, degree of alcohol use, characteristics associated with alcohol, and consequences of alcohol. There were a total of 333,246,875 views for all videos combined. While 89% of videos involved males, only 49% involved females. The videos had a median of 1,646 (interquartile range [IQR] 300 to 22,969) "like" designations and 33 (IQR 14 to 1,261) "dislike" designations each. Liquor was most frequently represented, followed by beer and then wine/champagne. Nearly one-half (44%) of videos contained a brand reference. Humor was juxtaposed with alcohol use in 79% of videos, and motor vehicle use was present in 24%. There were significantly more likes per dislike, indicating more positive sentiment, when there was representation of liquor (29.1 vs. 11.4, p = 0.008), brand references (32.1 vs. 19.2, p = 0.04), and/or physical attractiveness (67.5 vs. 17.8, p < 0.001). Internet videos depicting alcohol intoxication are heavily viewed. Nearly, half of these videos involve a brand-name reference. While these videos commonly juxtapose alcohol intoxication with characteristics such as humor and attractiveness, they infrequently depict negative clinical outcomes. The popularity of this site may provide an opportunity for public health intervention. Copyright © 2015 by the Research Society on Alcoholism.
NASA Astrophysics Data System (ADS)
Krzan, Grzegorz; Stępniak, Katarzyna
2017-09-01
In high-accuracy positioning using GNSS, the most common solution is still relative positioning using double-difference observations of dual-frequency measurements. An increasingly popular alternative to relative positioning are undifferenced approaches, which are designed to make full use of modern satellite systems and signals. Positions referenced to global International Terrestrial Reference Frame (ITRF2008) obtained from Precise Point Positioning (PPP) or Undifferenced (UD) network solutions have to be transformed to national (regional) reference frame, which introduces additional bases related to the transformation process. In this paper, satellite observations from two test networks using different observation time series were processed. The first test concerns the positioning accuracy from processing one year of dual-frequency GPS observations from 14 EUREF Permanent Network (EPN) stations using NAPEOS 3.3.1 software. The results were transformed into a national reference frame (PL-ETRF2000) and compared to positions from an EPN cumulative solution, which was adopted as the true coordinates. Daily observations were processed using PPP and UD multi-station solutions to determine the final accuracy resulting from satellite positioning, the transformation to national coordinate systems and Eurasian intraplate plate velocities. The second numerical test involved similar processing strategies of post-processing carried out using different observation time series (30 min., 1 hour, 2 hours, daily) and different classes of GNSS receivers. The centimeter accuracy of results presented in the national coordinate system satisfies the requirements of many surveying and engineering applications.
Self-Regulatory Capacities Are Depleted in a Domain-Specific Manner
Zhang, Rui; Stock, Ann-Kathrin; Rzepus, Anneka; Beste, Christian
2017-01-01
Performing an act of self-regulation such as making decisions has been suggested to deplete a common limited resource, which impairs all subsequent self-regulatory actions (ego depletion theory). It has however remained unclear whether self-referred decisions truly impair behavioral control even in seemingly unrelated cognitive domains, and which neurophysiological mechanisms are affected by these potential depletion effects. In the current study, we therefore used an inter-individual design to compare two kinds of depletion, namely a self-referred choice-based depletion and a categorization-based switching depletion, to a non-depleted control group. We used a backward inhibition (BI) paradigm to assess the effects of depletion on task switching and associated inhibition processes. It was combined with EEG and source localization techniques to assess both behavioral and neurophysiological depletion effects. The results challenge the ego depletion theory in its current form: Opposing the theory’s prediction of a general limited resource, which should have yielded comparable effects in both depletion groups, or maybe even a larger depletion in the self-referred choice group, there were stronger performance impairments following a task domain-specific depletion (i.e., the switching-based depletion) than following a depletion based on self-referred choices. This suggests at least partly separate and independent resources for various cognitive control processes rather than just one joint resource for all self-regulation activities. The implications are crucial to consider for people making frequent far-reaching decisions e.g., in law or economy. PMID:29033798
Self-Regulatory Capacities Are Depleted in a Domain-Specific Manner.
Zhang, Rui; Stock, Ann-Kathrin; Rzepus, Anneka; Beste, Christian
2017-01-01
Performing an act of self-regulation such as making decisions has been suggested to deplete a common limited resource, which impairs all subsequent self-regulatory actions (ego depletion theory). It has however remained unclear whether self-referred decisions truly impair behavioral control even in seemingly unrelated cognitive domains, and which neurophysiological mechanisms are affected by these potential depletion effects. In the current study, we therefore used an inter-individual design to compare two kinds of depletion, namely a self-referred choice-based depletion and a categorization-based switching depletion, to a non-depleted control group. We used a backward inhibition (BI) paradigm to assess the effects of depletion on task switching and associated inhibition processes. It was combined with EEG and source localization techniques to assess both behavioral and neurophysiological depletion effects. The results challenge the ego depletion theory in its current form: Opposing the theory's prediction of a general limited resource, which should have yielded comparable effects in both depletion groups, or maybe even a larger depletion in the self-referred choice group, there were stronger performance impairments following a task domain-specific depletion (i.e., the switching-based depletion) than following a depletion based on self-referred choices. This suggests at least partly separate and independent resources for various cognitive control processes rather than just one joint resource for all self-regulation activities. The implications are crucial to consider for people making frequent far-reaching decisions e.g., in law or economy.
Location, location, location: does early cancer in Barrett's esophagus have a preference?
Enestvedt, Brintha K; Lugo, Ricardo; Guarner-Argente, Carlos; Shah, Pari; Falk, Gary W; Furth, Emma; Ginsberg, Gregory G
2013-09-01
Early cancer (high-grade dysplasia [HGD] and intramucosal carcinoma [ImCa]) associated with Barrett's esophagus (BE) may have a circumferential spatial predilection. To describe the esophageal circumferential location of early cancer in BE. Retrospective study, single tertiary referral center. One hundred nineteen patients were referred for endoscopic eradication therapy for early cancer associated with BE. Endoscopic images and reports and pathology were reviewed. Circumferential location designation of early cancer in BE by using a clock-face orientation. One hundred nineteen of 131 patients referred for endoscopic eradication therapy had a location designation for their advanced histology (91.9%). There were a total of 57 patients (47.9%) with HGD and 62 patients (52.1%) with ImCa. There was a significantly higher rate of early cancer (HGD or ImCa) in the right hemisphere (12 to 6 o'clock location) compared with the left hemisphere (84.9% vs 15.1%, P < .0001). The highest percentage of early cancer was found in the 12 to 3 o'clock quadrant (64.7%); 71.9% of HGD and 58.1% of ImCa lesions were located in the 12 to 3 o'clock quadrant. Retrospective design, single center. Early cancer associated with BE is far more commonly found in the right hemisphere of the esophagus (12 to 6 o'clock) with the highest rate in the 12 to 3 o'clock quadrant. These findings support enhanced scrutiny of the right hemisphere of the esophagus during surveillance and endoscopic treatment of patients with BE. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
The report is a reference manual for RASSMlT Version 2.1, a computer program that was developed to simulate and aid in the design of sub-slab depressurization systems used for indoor radon mitigation. The program was designed to run on DOS-compatible personal computers to ensure ...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-27
...'') sets forth a variety of provisions designed to improve energy efficiency. (All references to EPCA refer... amended under this section shall be reasonably designed to produce test results which measure energy... a cabinet designed for the refrigerated storage of food at temperatures above 32 [deg]F and below 39...
Laslett, Mark; McDonald, Barry; Tropp, Hans; Aprill, Charles N; Öberg, Birgitta
2005-01-01
Background The tissue origin of low back pain (LBP) or referred lower extremity symptoms (LES) may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC) statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216) with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement (PCC) was estimated at 13%. "Exact" agreement between clinical and reference standard diagnoses was 32% and "clinical agreement" 51%. For six pathoanatomic categories (disc, facet joint, sacroiliac joint, hip joint, nerve root and spinal stenosis), PCC was 33% with actual agreement 56%. There was no overlap of 95% confidence intervals on any comparison. Diagnostic agreement on the six most common patho-anatomic categories produced a kappa of 0.31. Conclusion Clinical diagnoses agree with reference standards diagnoses more often than chance. Using available reference standards, most patients can have a tissue source of pain identified. PMID:15943873
Berthon, Beatrice; Spezi, Emiliano; Galavis, Paulina; Shepherd, Tony; Apte, Aditya; Hatt, Mathieu; Fayad, Hadi; De Bernardi, Elisabetta; Soffientini, Chiara D; Ross Schmidtlein, C; El Naqa, Issam; Jeraj, Robert; Lu, Wei; Das, Shiva; Zaidi, Habib; Mawlawi, Osama R; Visvikis, Dimitris; Lee, John A; Kirov, Assen S
2017-08-01
The aim of this paper is to define the requirements and describe the design and implementation of a standard benchmark tool for evaluation and validation of PET-auto-segmentation (PET-AS) algorithms. This work follows the recommendations of Task Group 211 (TG211) appointed by the American Association of Physicists in Medicine (AAPM). The recommendations published in the AAPM TG211 report were used to derive a set of required features and to guide the design and structure of a benchmarking software tool. These items included the selection of appropriate representative data and reference contours obtained from established approaches and the description of available metrics. The benchmark was designed in a way that it could be extendable by inclusion of bespoke segmentation methods, while maintaining its main purpose of being a standard testing platform for newly developed PET-AS methods. An example of implementation of the proposed framework, named PETASset, was built. In this work, a selection of PET-AS methods representing common approaches to PET image segmentation was evaluated within PETASset for the purpose of testing and demonstrating the capabilities of the software as a benchmark platform. A selection of clinical, physical, and simulated phantom data, including "best estimates" reference contours from macroscopic specimens, simulation template, and CT scans was built into the PETASset application database. Specific metrics such as Dice Similarity Coefficient (DSC), Positive Predictive Value (PPV), and Sensitivity (S), were included to allow the user to compare the results of any given PET-AS algorithm to the reference contours. In addition, a tool to generate structured reports on the evaluation of the performance of PET-AS algorithms against the reference contours was built. The variation of the metric agreement values with the reference contours across the PET-AS methods evaluated for demonstration were between 0.51 and 0.83, 0.44 and 0.86, and 0.61 and 1.00 for DSC, PPV, and the S metric, respectively. Examples of agreement limits were provided to show how the software could be used to evaluate a new algorithm against the existing state-of-the art. PETASset provides a platform that allows standardizing the evaluation and comparison of different PET-AS methods on a wide range of PET datasets. The developed platform will be available to users willing to evaluate their PET-AS methods and contribute with more evaluation datasets. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
A novel body frame based approach to aerospacecraft attitude tracking.
Ma, Carlos; Chen, Michael Z Q; Lam, James; Cheung, Kie Chung
2017-09-01
In the common practice of designing an attitude tracker for an aerospacecraft, one transforms the Newton-Euler rotation equations to obtain the dynamic equations of some chosen inertial frame based attitude metrics, such as Euler angles and unit quaternions. A Lyapunov approach is then used to design a controller which ensures asymptotic convergence of the attitude to the desired orientation. Although this design methodology is pretty standard, it usually involves singularity-prone coordinate transformations which complicates the analysis process and controller design. A new, singularity free error feedback method is proposed in the paper to provide simple and intuitive stability analysis and controller synthesis. This new body frame based method utilizes the concept of Euleraxis and angles to generate the smallest error angles from a body frame perspective, without coordinate transformations. Global tracking convergence is illustrated with the use of a feedback linearizing PD tracker, a sliding mode controller, and a model reference adaptive controller. Experimental results are also obtained on a quadrotor platform with unknown system parameters and disturbances, using a boundary layer approximated sliding mode controller, a PIDD controller, and a unit sliding mode controller. Significant tracking quality is attained. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Handbook for Nickel-Hydrogen Batteries
NASA Technical Reports Server (NTRS)
Dunlop, James D.; Gopalakrishna, M. Rao; Yi, Thomas Y.
1993-01-01
Nickel-hydrogen (NiH2) batteries are finding more applications in the aerospace energy storage. Since 1983, NiH2 batteries have become the primary energy storage system used for Geosynchronous-Orbit (GEO) Satellites. The first NASA application for NiH2 batteries was the Low Earth Orbit (LEO) Hubble Space Telescope Satellite launched in 1990. The handbook was prepared as a reference book to aid in the application of this technology. That is, to aid in the cell and battery design, procurement, testing, and handling of NiH2 batteries. The design of individual pressure vessel NiH2 cells is covered in Chapter l. LEO and GEO applications and their requirements are discussed in Chapter 2. The design of NiH2 batteries for both GEO and LEO applications is discussed in Chapter 3. Advanced design concepts such as the common pressure vessel and bipolar NiH2 batteries are described in Chapter 4. Performance data are presented in Chapter 5. Storage and handling of the NiH2 cells and batteries are discussed in Chapter 6. Standard test procedures are presented in Chapter 7. Cell and battery procurements are discussed in Chapter 8. Finally, safety procedures are discussed in Chapter 9.
Improving Program Design and Assessment with Broadening Participation Resources
NASA Astrophysics Data System (ADS)
Siegfried, D.; Johnson, A.; Thomas, S. H.; Fauver, A.; Detrick, L.
2012-12-01
Many theoretical and research-based approaches suggest how to best use mentoring to enhance an undergraduate research program. The Institute for Broadening Participation's Pathways to Engineering and Pathways to Ocean Sciences projects synthesized a set of mentoring studies, theoretical sources, and other texts pertinent to undergraduate research program design into a suite of practical tools that includes an online mentoring manual, an online reference library of mentoring and diversity literature, and practical guides such as Using Social Media to Build Diversity in Your REU. The overall goal is to provide easy-to-access resources that can assist faculty and program directors in implementing or honing the mentoring elements in their research programs for undergraduates. IBP's Online Mentoring Manual addresses common themes, such as modeling, student self-efficacy, career development, retention and evaluation. The Online Diversity Reference Library provides a comprehensive, annotated selection of key policy documents, research studies, intervention studies, and other texts on broadening participation in science, technology, engineering and mathematics. IBP's suite of tools provides the theoretical underpinnings and research findings that can help leaders in education integrate site-appropriate mentoring elements into their educational programs. Program directors and faculty from a variety of program types and disciplines have benefitted from using the Manual and other resources. IBP continues the work of translating and synthesizing theory to practice and welcomes your participation and partnership in that effort.
Development of a PCR protocol to detect aflatoxigenic molds in food products.
Luque, M Isabel; Rodríguez, Alicia; Andrade, María J; Martín, Alberto; Córdoba, Juan J
2012-01-01
Aflatoxins are secondary metabolites produced mainly by Aspergillus species growing in foodstuffs. Because aflatoxins have important health effects, the detection of early contamination of foods by aflatoxigenic molds should be useful. In the present work, a reliable conventional PCR method for detecting aflatoxigenic molds of various species was developed. Fifty-six aflatoxigenic and nonaflatoxigenic strains commonly reported in foodstuffs were tested. Aflatoxin production was first confirmed by micellar electrokinetic capillary electrophoresis or/and high-pressure liquid chromatography-mass spectrometry. Based on the conserved regions of the O-methyltransferase gene (omt-1) involved in the aflatoxin biosynthetic pathway, six primer pairs were designed. With only the designed primer pair AFF1-AFR3, the expected PCR product (381 bp) was obtained in all of the tested aflatoxigenic strains of various species and genera. Amplification products were not obtained with this primer pair for any of the nonaflatoxigenic reference molds. However, an amplicon of 453 bp was obtained for all aflatoxigenic and nonaflatoxigenic mold reference strains with a PCR protocol based on the constitutive fungal β-tubulin gene, which was used as a positive fungal control. The PCR protocol based on omt-1 detected as little as 15 pg of DNA from aflatoxigenic molds and 10(2) to 10(3) CFU/g in contaminated food samples. This PCR protocol should be used as a routine technique to detect aflatoxigenic molds in foods.
Bedside diagnosis of dysphagia: a systematic review.
O'Horo, John C; Rogus-Pulia, Nicole; Garcia-Arguello, Lisbeth; Robbins, JoAnne; Safdar, Nasia
2015-04-01
Dysphagia is associated with aspiration, pneumonia, and malnutrition, but remains challenging to identify at the bedside. A variety of exam protocols and maneuvers are commonly used, but the efficacy of these maneuvers is highly variable. We conducted a comprehensive search of 7 databases, including MEDLINE, Embase, and Scopus, from each database's earliest inception through June 9, 2014. Studies reporting diagnostic performance of a bedside examination maneuver compared to a reference gold standard (videofluoroscopic swallow study or flexible endoscopic evaluation of swallowing with sensory testing) were included for analysis. From each study, data were abstracted based on the type of diagnostic method and reference standard study population and inclusion/exclusion characteristics, design, and prediction of aspiration. The search strategy identified 38 articles meeting inclusion criteria. Overall, most bedside examinations lacked sufficient sensitivity to be used for screening purposes across all patient populations examined. Individual studies found dysphonia assessments, abnormal pharyngeal sensation assessments, dual axis accelerometry, and 1 description of water swallow testing to be sensitive tools, but none were reported as consistently sensitive. A preponderance of identified studies was in poststroke adults, limiting the generalizability of results. No bedside screening protocol has been shown to provide adequate predictive value for presence of aspiration. Several individual exam maneuvers demonstrated reasonable sensitivity, but reproducibility and consistency of these protocols was not established. More research is needed to design an optimal protocol for dysphagia detection. © 2015 Society of Hospital Medicine.
Woody Vegetation on Levees? - Research Experiences and Design Suggestions
NASA Astrophysics Data System (ADS)
Lammeranner, Walter
2013-04-01
Recent flood events in Austria have reawakened practical and scientific interest in the stability of levees. One focus amongst others has been taken on the relationship between vegetation and levee stability with special reference to the role of woody plants. The effects of woody plants are undoubtedly manifold: On the one hand they can potentially have a negative influence and endanger levees, which is why many guidelines ban woody vegetation to preserve stability, visual inspection and unhindered flood-fight access. On the other hand woody vegetation can have several positive impacts on soil stability and which effects prevail depends largely on types and characteristics of plants. This shows how controversially woody plants on levees can be discussed and the strong need for further research in this field. In order to obtain new insights and widen horizons for this controversial issue, a research project carried out by the Institute of Soil Bioengineering and Landscape Construction - at the University of Natural Resources and Life Sciences, Vienna - was launched. This project deals with several aspects of effects of woody plants have on levees and focuses particularly on shrubby woody plants. The examined vegetation type is a dense stand of willows - Purple-Willows (Salix purpurea L.) - commonly used for stabilization of river embankments. The proposed contribution discusses the gained results with reference to levee stability and existing levee vegetation guidelines and gives design suggestions for compatible woody vegetation on levees.
How to deal with burden of critical illness: A comparison of strategies in different areas of China.
Liu, Pengcheng; Jiang, Liwen; Li, Chengyue; Sun, Mei; Rieger, Alexander; Hao, Mo
2014-05-01
This article aims to introduce, compare and analyze the design and development of Critical Illness Insurance systems in different parts of China under different social and economic conditions, to explain their characteristics and similarities. It may provide references to other countries, especially developing countries, to solve the problem of high medical costs. According to the methods in Comparative Economics, 3 areas (Taicang in Jiangsu, Zhanjiang in Guangdong, Xunyi in Shanxi) which are in high, medium and low socio-economic condition respectively were chosen in China. Their critical illness insurance systems were analyzed in the study. Each system shares several common points, including coordinating urban and rural medical insurance fund, financing from the basic medical insurance surplus, and exploring payment reform and so on. But in the way of management, Taicang and Zhanjiang cooperate with commercial insurance agencies, but Xunyi chooses autonomous management by government. In Xunyi, multi-channel financing is relatively more dispersed, while funds of Taicang and Zhanjiang are mainly from the basic medical insurance surplus. The specific method of payment is different among these three areas. Because of the differences in economic development, population structure, and sources of funds, each area took their own mode on health policy orientation, financing, payment, coverage, and fund management to design their Critical Illness Insurance systems. This might provide references to other areas in China and other developing countries in the world.
Genetics Home Reference: ornithine translocase deficiency
... Diagnosis of Japanese patients with HHH syndrome by molecular genetic analysis: a common mutation, R179X. J Hum Genet. ... M, Fariello G, Dionisi-Vici C. Clinical and molecular findings in hyperornithinemia-hyperammonemia-homocitrullinuria ... Bulletins Genetics Home Reference Celebrates Its ...
ERIC Educational Resources Information Center
Armstrong, Julie; And Others
For Postpartum Education for Parents (PEP) volunteers, this reference guide provides background information about the common concerns of parents. Extensively reviewed for accuracy and content by pediatricians, psychologists, obstetricians, nurses, and childbirth educators, the guide contains a summary discussion of the postpartum infant and…
Biobased materials refer to products that mainly consist of a substance (or substances) derived from living matter (biomass) and either occur naturally or are synthesized, or it may refer to products made by processes that use biomass. Following a strict definition, many common m...
Do children with gender dysphoria have intense/obsessional interests?
VanderLaan, Doug P; Postema, Lori; Wood, Hayley; Singh, Devita; Fantus, Sophia; Hyun, Jessica; Leef, Jonathan; Bradley, Susan J; Zucker, Kenneth J
2015-01-01
This study examined whether children clinically referred for gender dysphoria (GD) show increased symptoms of autism spectrum disorder (ASD). Circumscribed preoccupations or intense interests were considered as overlapping symptoms expressed in GD and ASD. In gender-referred children (n = 534; 82.2% male) and their siblings (n = 419; 57.5% male), we examined Items 9 and 66 on the Child Behavior Checklist, which measure obsessions and compulsions, respectively. Non-GD clinic-referred (n = 1,201; 48.5% male) and nonreferred (n = 1,201; 48.5% male) children were also examined. Gender-referred children were elevated compared to all other groups for Item 9, and compared to siblings and nonreferred children for Item 66. A gender-related theme was significantly more common for gender-referred boys than male siblings on Item 9 only. A gender-related theme was not significantly more common for gender-referred girls compared to their female siblings on either item. The findings for Item 9 support the idea that children with GD show an elevation in obsessional interests. For gender-referred boys in particular, gender-related themes constituted more than half of the examples provided by their mothers. Intense/obsessional interests in children with GD may be one of the factors underlying the purported link between GD and ASD.
Wang, Genhong; Chen, Yanfei; Zhang, Xiaoying; Bai, Bingchuan; Yan, Hao; Qin, Daoyuan; Xia, Qingyou
2018-06-01
The silkworm, Bombyx mori, is one of the world's most economically important insect. Surveying variations in gene expression among multiple tissue/organ samples will provide clues for gene function assignments and will be helpful for identifying genes related to economic traits or specific cellular processes. To ensure their accuracy, commonly used gene expression quantification methods require a set of stable reference genes for data normalization. In this study, 24 candidate reference genes were assessed in 10 tissue/organ samples of day 3 fifth-instar B. mori larvae using geNorm and NormFinder. The results revealed that, using the combination of the expression of BGIBMGA003186 and BGIBMGA008209 was the optimum choice for normalizing the expression data of the B. mori tissue/organ samples. The most stable gene, BGIBMGA003186, is recommended if just one reference gene is used. Moreover, the commonly used reference gene encoding cytoplasmic actin was the least appropriate reference gene of the samples investigated. The reliability of the selected reference genes was further confirmed by evaluating the expression profiles of two cathepsin genes. Our results may be useful for future studies involving the quantification of relative gene expression levels of different tissue/organ samples in B. mori. © 2018 Wiley Periodicals, Inc.
Optimizing product life cycle processes in design phase
NASA Astrophysics Data System (ADS)
Faneye, Ola. B.; Anderl, Reiner
2002-02-01
Life cycle concepts do not only serve as basis in assisting product developers understand the dependencies between products and their life cycles, they also help in identifying potential opportunities for improvement in products. Common traditional concepts focus mainly on energy and material flow across life phases, necessitating the availability of metrics derived from a reference product. Knowledge of life cycle processes won from an existing product is directly reused in its redesign. Depending on sales volume nevertheless, the environmental impact before product optimization can be substantial. With modern information technologies today, computer-aided life cycle methodologies can be applied well before product use. On the basis of a virtual prototype, life cycle processes are analyzed and optimized, using simulation techniques. This preventive approach does not only help in minimizing (or even eliminating) environmental burdens caused by product, costs incurred due to changes in real product can also be avoided. The paper highlights the relationship between product and life cycle and presents a computer-based methodology for optimizing the product life cycle during design, as presented by SFB 392: Design for Environment - Methods and Tools at Technical University, Darmstadt.
Small modular reactor: First-of-a-Kind (FOAK) and Nth-of-a-Kind (NOAK) Economic Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boldon, Lauren M.; Sabharwall, Piyush
2014-08-01
Small modular reactors (SMRs) refer to any reactor design in which the electricity generated is less than 300 MWe. Often medium sized reactors with power less than 700 MWe are also grouped into this category. Internationally, the development of a variety of designs for SMRs is booming with many designs approaching maturity and even in or nearing the licensing stage. It is for this reason that a generalized yet comprehensive economic model for first of a kind (FOAK) through nth of a kind (NOAK) SMRs based upon rated power, plant configuration, and the fiscal environment was developed. In the model,more » a particular project’s feasibility is assessed with regards to market conditions and by commonly utilized capital budgeting techniques, such as the net present value (NPV), internal rate of return (IRR), Payback, and more importantly, the levelized cost of energy (LCOE) for comparison to other energy production technologies. Finally, a sensitivity analysis was performed to determine the effects of changing debt, equity, interest rate, and conditions on the LCOE.« less
Genetics Home Reference: Guillain-Barré syndrome
... most common type in North America and Europe, accounting for approximately 90 percent of cases of Guillain- ... syndrome is also more common in Asian countries, accounting for approximately 20 percent of cases in these ...
26 CFR 1.1502-33 - Earnings and profits.
Code of Federal Regulations, 2010 CFR
2010-04-01
...-tier members and consolidating the group's earnings and profits in the common parent. References in... tax year beginning on or after January 1, 1995. The statement must be signed by the common parent, and... acquisition of either the assets of the common parent of the terminating group in a reorganization described...
Why Do We Keep Catching the Common Cold?
ERIC Educational Resources Information Center
Gillen, Alan L.; Mayor, Heather D.
1995-01-01
Describes activities for biology teachers that will stimulate discussions on virus structure, cell biology, rhino viruses, and new trends in treating the common cold. Provides opportunity for inquiry and problem solving in exercises that emphasize an understanding of how common cold viruses might pack inside nasal epithelial cells. (14 references)…
The “Common Rule” refers to the federal regulations that govern research involving human subjects. These regulations have been largely unchanged since 1981, while the research they cover has continued to evolve. After a 6-year rulemaking process, the Common Rule was ...
NASA Technical Reports Server (NTRS)
Isenberg, J. M.; Southall, J. W.
1979-01-01
The Integrated Programs for Aerospace Vehicle Design (IPAD) is a computing system to support company-wide design information processing. This document presents a brief description of the management system used to direct and control a product-oriented program. This document, together with the reference design process (CR 2981) and the manufacture interactions with the design process (CR 2982), comprises the reference information that forms the basis for specifying IPAD system requirements.
Design Reference Missions for Deep-Space Optical Communication
NASA Astrophysics Data System (ADS)
Breidenthal, J.; Abraham, D.
2016-05-01
We examined the potential, but uncertain, NASA mission portfolio out to a time horizon of 20 years, to identify mission concepts that potentially could benefit from optical communication, considering their communications needs, the environments in which they would operate, and their notional size, weight, and power constraints. A set of 12 design reference missions was selected to represent the full range of potential missions. These design reference missions span the space of potential customer requirements, and encompass the wide range of applications that an optical ground segment might eventually be called upon to serve. The design reference missions encompass a range of orbit types, terminal sizes, and positions in the solar system that reveal the chief system performance variables of an optical ground segment, and may be used to enable assessments of the ability of alternative systems to meet various types of customer needs.
Survey of Ophthalmologists Regarding Practice Patterns for Dry Eye and Sjogren Syndrome.
Bunya, Vatinee Y; Fernandez, Karen B; Ying, Gui-Shuang; Massaro-Giordano, Mina; Macchi, Ilaria; Sulewski, Michael E; Hammersmith, Kristin M; Nagra, Parveen K; Rapuano, Christopher J; Orlin, Stephen E
2018-01-15
To survey ophthalmologists about current practice patterns regarding the evaluation of dry eye patients and referrals for a Sjogren syndrome (SS) workup. An online survey was sent to ophthalmologists affiliated with the Scheie Eye Institute or Wills Eye Hospital using REDCap in August 2015. Descriptive statistics were used to summarize the data. Four hundred seventy-four survey invitations were sent out and 101 (21%) ophthalmologists completed the survey. The common traditional dry eye test performed was corneal fluorescein staining (62%) and the most common newer dry eye test performed was tear osmolarity (18%). Half of respondents (51%) refer fewer than 5% of their dry eye patients for SS workups, with 18% reporting that they never refer any patients. The most common reasons for referrals included positive review of systems (60%), severe dry eye symptoms (51%) or ocular signs (47%), or dry eye that is refractory to treatment (42%). The majority (83%) felt that there is a need for an evidence-based standardized screening tool for dry eye patients to decide who should be referred for evaluation for SS. Ophthalmologists continue to prefer the use of traditional dry eye tests in practice, with the most common test being corneal fluorescein staining. There is an underreferral of dry eye patients for SS workups, which is contributing to the continued underdiagnosis of the disease. Most respondents felt that there was a need for an evidence-based standardized screening tool to decide which dry eye patients should be referred for SS evaluations.
Re-conceiving building design quality: A review of building users in their social context.
Watson, Kelly J; Evans, James; Karvonen, Andrew; Whitley, Tim
2016-05-01
Considerable overlap exists between post-occupancy research evaluating building design quality and the concept of 'social value', popularised by its recent application to issues of the public realm. To outline this potential research agenda, the paper reviews design quality research on buildings in relation to users and their social context where the term 'social context' refers to building user group dynamics, a combination of organisational cultures, management strategies, and social norms and practices. The review is conducted across five key building types, namely housing, workplaces, healthcare, education, and the retail/service sector. Research commonalities and gaps are identified in order to build a more comprehensive picture of the design quality literature and its handling of users in their social context. The key findings concerning each building type are presented visually. It is concluded that the design quality field comprises a patchwork of relatively isolated studies of various building types, with significant potential for theoretical and empirical development through interdisciplinary collaboration. Users tend to be conceived as anonymous and autonomous individuals with little analysis of user identity or interaction. Further, the contextual impact of user group dynamics on the relationship between building design and building user is rarely addressed in the literature. Producing a more nuanced understanding of users in situ is proposed as an important area for future design quality research.
Re-conceiving building design quality: A review of building users in their social context
Evans, James; Karvonen, Andrew; Whitley, Tim
2014-01-01
Considerable overlap exists between post-occupancy research evaluating building design quality and the concept of ‘social value’, popularised by its recent application to issues of the public realm. To outline this potential research agenda, the paper reviews design quality research on buildings in relation to users and their social context where the term ‘social context’ refers to building user group dynamics, a combination of organisational cultures, management strategies, and social norms and practices. The review is conducted across five key building types, namely housing, workplaces, healthcare, education, and the retail/service sector. Research commonalities and gaps are identified in order to build a more comprehensive picture of the design quality literature and its handling of users in their social context. The key findings concerning each building type are presented visually. It is concluded that the design quality field comprises a patchwork of relatively isolated studies of various building types, with significant potential for theoretical and empirical development through interdisciplinary collaboration. Users tend to be conceived as anonymous and autonomous individuals with little analysis of user identity or interaction. Further, the contextual impact of user group dynamics on the relationship between building design and building user is rarely addressed in the literature. Producing a more nuanced understanding of users in situ is proposed as an important area for future design quality research. PMID:27110217
NASA Technical Reports Server (NTRS)
Chen, Shu-cheng, S.
2009-01-01
For the preliminary design and the off-design performance analysis of axial flow turbines, a pair of intermediate level-of-fidelity computer codes, TD2-2 (design; reference 1) and AXOD (off-design; reference 2), are being evaluated for use in turbine design and performance prediction of the modern high performance aircraft engines. TD2-2 employs a streamline curvature method for design, while AXOD approaches the flow analysis with an equal radius-height domain decomposition strategy. Both methods resolve only the flows in the annulus region while modeling the impact introduced by the blade rows. The mathematical formulations and derivations involved in both methods are documented in references 3, 4 for TD2-2) and in reference 5 (for AXOD). The focus of this paper is to discuss the fundamental issues of applicability and compatibility of the two codes as a pair of companion pieces, to perform preliminary design and off-design analysis for modern aircraft engine turbines. Two validation cases for the design and the off-design prediction using TD2-2 and AXOD conducted on two existing high efficiency turbines, developed and tested in the NASA/GE Energy Efficient Engine (GE-E3) Program, the High Pressure Turbine (HPT; two stages, air cooled) and the Low Pressure Turbine (LPT; five stages, un-cooled), are provided in support of the analysis and discussion presented in this paper.
Ferreira, Patrícia; Taveira-Gomes, Isabel; Severo, Milton; Ferreira, Maria Amélia
2016-01-01
Background Computer-based learning (CBL) has been widely used in medical education, and reports regarding its usage and effectiveness have ranged broadly. Most work has been done on the effectiveness of CBL approaches versus traditional methods, and little has been done on the comparative effects of CBL versus CBL methodologies. These findings urged other authors to recommend such studies in hopes of improving knowledge about which CBL methods work best in which settings. Objective In this systematic review, we aimed to characterize recent studies of the development of software platforms and interventions in medical education, search for common points among studies, and assess whether recommendations for CBL research are being taken into consideration. Methods We conducted a systematic review of the literature published from 2003 through 2013. We included studies written in English, specifically in medical education, regarding either the development of instructional software or interventions using instructional software, during training or practice, that reported learner attitudes, satisfaction, knowledge, skills, or software usage. We conducted 2 latent class analyses to group articles according to platform features and intervention characteristics. In addition, we analyzed references and citations for abstracted articles. Results We analyzed 251 articles. The number of publications rose over time, and they encompassed most medical disciplines, learning settings, and training levels, totaling 25 different platforms specifically for medical education. We uncovered 4 latent classes for educational software, characteristically making use of multimedia (115/251, 45.8%), text (64/251, 25.5%), Web conferencing (54/251, 21.5%), and instructional design principles (18/251, 7.2%). We found 3 classes for intervention outcomes: knowledge and attitudes (175/212, 82.6%), knowledge, attitudes, and skills (11.8%), and online activity (12/212, 5.7%). About a quarter of the articles (58/227, 25.6%) did not hold references or citations in common with other articles. The number of common references and citations increased in articles reporting instructional design principles (P=.03), articles measuring online activities (P=.01), and articles citing a review by Cook and colleagues on CBL (P=.04). There was an association between number of citations and studies comparing CBL versus CBL, independent of publication date (P=.02). Conclusions Studies in this field vary highly, and a high number of software systems are being developed. It seems that past recommendations regarding CBL interventions are being taken into consideration. A move into a more student-centered model, a focus on implementing reusable software platforms for specific learning contexts, and the analysis of online activity to track and predict outcomes are relevant areas for future research in this field. PMID:27480053
ERIC Educational Resources Information Center
Allen, Deborah; Tanner, Kimberly
2007-01-01
This article discusses a systematic approach to designing significant learning experiences, often referred to as the "backward design process," which has been popularized by Wiggins and McTighe (1998) and is included as a central feature of L. Dee Fink's model for integrated course design (Fink, 2003). The process is referred to as backward…
Accelerating Cogent Confabulation: An Exploration in the Architecture Design Space
2008-06-01
DATES COVERED (From - To) 1-8 June 2008 4. TITLE AND SUBTITLE ACCELERATING COGENT CONFABULATION: AN EXPLORATION IN THE ARCHITECTURE DESIGN SPACE 5a...spiking neural networks is proposed in reference [8]. Reference [9] investigates the architecture design of a Brain-state-in-a-box model. The...Richard Linderman2, Thomas Renz2, Qing Wu1 Accelerating Cogent Confabulation: an Exploration in the Architecture Design Space POSTPRINT complexity
Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.
Lo, Y C; Armbruster, David A
2012-04-01
Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.
Shellfish/crustacean oral allergy syndrome among national service pre-enlistees in Singapore
Arulanandam, Shalini; Tan, Sze-Chin; Tan, Teck-Choon; Chan, Grace Yin-Lai; Tan, Justina Wei-Lyn; Yeow, Mark Chong-Wei; Tang, Chwee-Ying; Hou, Jinfeng; Leong, Khai-Pang
2018-01-01
Background All Singaporean males undergo medical screening prior to compulsory military service. A history of possible food allergy may require referral to a specialist Allergy clinic to ensure that special dietary needs can be taken into account during field training and deployment. Objective To study the pattern of food allergy among pre-enlistees who were referred to a specialist allergy clinic to work up suspected food allergy. Methods Retrospective study of all pre-enlistees registered in the Clinical Immunology/Allergy New Case Registry referred to the Allergy Clinic from 1 August 2015 to 31 May 2016 for suspected food allergy. Results One hundred twenty pre-enlistees reporting food allergy symptoms other than rash alone were referred to the Allergy Clinic during the study period. Of these, 77 (64.2%) had food allergy. Among those with food allergy, mean age was 19.1 ± 1.5 years. They comprised predominantly Chinese (66.2%) and Malays (20.8%). The most commonly reported foods were shellfish/crustaceans (78%), peanut (15.6%), and egg (6.5%). Self-limiting oral allergy syndrome, OAS (itchy lips and throat with/without lip angioedema) was the most common manifestation (n = 33, 42.9%) followed by anaphylaxis (n = 23, 29.9%). Majority of OAS was from shellfish/crustacean (90.6%); of which shrimp (30.3%), crab (15.2%), and lobster (3.0%) were the most common. Mild childhood asthma (69.7%), allergic rhinitis (6.3%), and eczema (6.1%) were the most common atopic conditions among individuals with shellfish/crustacean OAS. This pattern was similar for shellfish/crustacean anaphylaxis. Skin prick tests were most commonly positive for shrimp (OAS 87.1% vs. anaphylaxis 100%), crab (OAS 95.8% vs. 90.9%), and lobster (OAS 91.7% vs. 63.6%). Conclusion OAS to shellfish/crustaceans was more common than anaphylaxis among this study population of young males referred for food allergy symptoms other than rash alone. PMID:29732294
Shellfish/crustacean oral allergy syndrome among national service pre-enlistees in Singapore.
Thong, Bernard Yu-Hor; Arulanandam, Shalini; Tan, Sze-Chin; Tan, Teck-Choon; Chan, Grace Yin-Lai; Tan, Justina Wei-Lyn; Yeow, Mark Chong-Wei; Tang, Chwee-Ying; Hou, Jinfeng; Leong, Khai-Pang
2018-04-01
All Singaporean males undergo medical screening prior to compulsory military service. A history of possible food allergy may require referral to a specialist Allergy clinic to ensure that special dietary needs can be taken into account during field training and deployment. To study the pattern of food allergy among pre-enlistees who were referred to a specialist allergy clinic to work up suspected food allergy. Retrospective study of all pre-enlistees registered in the Clinical Immunology/Allergy New Case Registry referred to the Allergy Clinic from 1 August 2015 to 31 May 2016 for suspected food allergy. One hundred twenty pre-enlistees reporting food allergy symptoms other than rash alone were referred to the Allergy Clinic during the study period. Of these, 77 (64.2%) had food allergy. Among those with food allergy, mean age was 19.1 ± 1.5 years. They comprised predominantly Chinese (66.2%) and Malays (20.8%). The most commonly reported foods were shellfish/crustaceans (78%), peanut (15.6%), and egg (6.5%). Self-limiting oral allergy syndrome, OAS (itchy lips and throat with/without lip angioedema) was the most common manifestation (n = 33, 42.9%) followed by anaphylaxis (n = 23, 29.9%). Majority of OAS was from shellfish/crustacean (90.6%); of which shrimp (30.3%), crab (15.2%), and lobster (3.0%) were the most common. Mild childhood asthma (69.7%), allergic rhinitis (6.3%), and eczema (6.1%) were the most common atopic conditions among individuals with shellfish/crustacean OAS. This pattern was similar for shellfish/crustacean anaphylaxis. Skin prick tests were most commonly positive for shrimp (OAS 87.1% vs. anaphylaxis 100%), crab (OAS 95.8% vs. 90.9%), and lobster (OAS 91.7% vs. 63.6%). OAS to shellfish/crustaceans was more common than anaphylaxis among this study population of young males referred for food allergy symptoms other than rash alone.
Scaffolding Students' Development of Creative Design Skills: A Curriculum Reference Model
ERIC Educational Resources Information Center
Lee, Chien-Sing; Kolodner, Janet L.
2011-01-01
This paper provides a framework for promoting creative design capabilities in the context of achieving community goals pertaining to sustainable development among high school students. The framework can be used as a reference model to design formal or out-of-school curriculum units in any geographical region. This theme is chosen due to its…
Floristry. Instructor Guide [and] Student Reference. Volume 28, Number 1 [and] Volume 28, Number 2.
ERIC Educational Resources Information Center
Rothenberger, Barbara; And Others
This instructor guide and the corresponding student reference contain 7 units that include 30 lessons for a course in floristry. The lessons topics are as follows: the floristry industry, plant identification, post-harvest handling, the mechanics of floral design, basic principles of floral design, construction of various types of designs, and…
Flight dynamics analysis and simulation of heavy lift airships. Volume 5: Programmer's manual
NASA Technical Reports Server (NTRS)
Ringland, R. F.; Tischler, M. B.; Jex, H. R.; Emmen, R. D.; Ashkenas, I. L.
1982-01-01
The Programmer's Manual contains explanations of the logic embodied in the various program modules, a dictionary of program variables, a subroutine listing, subroutine/common block/cross reference listing, and a calling/called subroutine cross reference listing.
The Identification and Modeling of Visual Cue Usage in Manual Control Task Experiments
NASA Technical Reports Server (NTRS)
Sweet, Barbara Townsend; Trejo, Leonard J. (Technical Monitor)
1999-01-01
Many fields of endeavor require humans to conduct manual control tasks while viewing a perspective scene. Manual control refers to tasks in which continuous, or nearly continuous, control adjustments are required. Examples include flying an aircraft, driving a car, and riding a bicycle. Perspective scenes can arise through natural viewing of the world, simulation of a scene (as in flight simulators), or through imaging devices (such as the cameras on an unmanned aerospace vehicle). Designers frequently have some degree of control over the content and characteristics of a perspective scene; airport designers can choose runway markings, vehicle designers can influence the size and shape of windows, as well as the location of the pilot, and simulator database designers can choose scene complexity and content. Little theoretical framework exists to help designers determine the answers to questions related to perspective scene content. An empirical approach is most commonly used to determine optimum perspective scene configurations. The goal of the research effort described in this dissertation has been to provide a tool for modeling the characteristics of human operators conducting manual control tasks with perspective-scene viewing. This is done for the purpose of providing an algorithmic, as opposed to empirical, method for analyzing the effects of changing perspective scene content for closed-loop manual control tasks.
Spaceship Discovery's Crew and Cargo Lander Module Designs for Human Exploration of Mars
NASA Astrophysics Data System (ADS)
Benton, Mark G.
2008-01-01
The Spaceship Discovery design was first presented at STAIF 2006. This conceptual design space vehicle architecture for human solar system exploration includes two types of Mars exploration lander modules: A piloted crew lander, designated Lander Module 2 (LM2), and an autonomous cargo lander, designated Lander Module 3 (LM3). The LM2 and LM3 designs were first presented at AIAA Space 2007. The LM2 and LM3 concepts have recently been extensively redesigned. The specific objective of this paper is to present these revised designs. The LM2 and LM3 landers are based on a common design that can be configured to carry either crew or cargo. They utilize a combination of aerodynamic reentry, parachutes, and propulsive braking to decelerate from orbital velocity to a soft landing. The LM2 crew lander provides two-way transportation for a nominal three-person crew between Mars orbit and the surface, and provides life support for a 30-day contingency mission. It contains an ascent section to return the crew to orbit after completion of surface operations. The LM3 cargo lander provides one-way, autonomous transportation of cargo from Mars orbit to the surface and can be configured to carry a mix of consumables and equipment, or equipment only. Lander service life and endurance is based on the Spaceship Discovery conjunction-class Design Reference Mission 2. The LM3 is designed to extend the surface stay for three crew members in an LM2 crew lander such that two sets of crew and cargo landers enable human exploration of the surface for the bulk of the 454 day wait time at Mars, in two shifts of three crew members each. Design requirements, mission profiles, mass properties, performance data, and configuration layouts are presented for the LM2 crew and LM3 cargo landers. These lander designs are a proposed solution to the problem of safely transporting a human crew from Mars orbit to the surface, sustaining them for extended periods of time on the surface, and returning them safely to orbit. They are based on reliable and proven technology and build on an extensive heritage of successful unmanned probes. Safety, redundancy, and abort and rescue capabilities are stressed in the design and operations concepts. The designs share many common features, hardware, subsystems, and flight control modes to reduce development cost.
Recognizing an Irregular Heart Rhythm
... a workout, consider checking your rhythm as well. Atrial fibrillation, also referred to as AF, is a common ... upper chambers, or atria, of the heart. “While atrial fibrillation is not common among young people, it can ...
NASA Astrophysics Data System (ADS)
Menne, Matthew J.; Williams, Claude N., Jr.
2005-10-01
An evaluation of three hypothesis test statistics that are commonly used in the detection of undocumented changepoints is described. The goal of the evaluation was to determine whether the use of multiple tests could improve undocumented, artificial changepoint detection skill in climate series. The use of successive hypothesis testing is compared to optimal approaches, both of which are designed for situations in which multiple undocumented changepoints may be present. In addition, the importance of the form of the composite climate reference series is evaluated, particularly with regard to the impact of undocumented changepoints in the various component series that are used to calculate the composite.In a comparison of single test changepoint detection skill, the composite reference series formulation is shown to be less important than the choice of the hypothesis test statistic, provided that the composite is calculated from the serially complete and homogeneous component series. However, each of the evaluated composite series is not equally susceptible to the presence of changepoints in its components, which may be erroneously attributed to the target series. Moreover, a reference formulation that is based on the averaging of the first-difference component series is susceptible to random walks when the composition of the component series changes through time (e.g., values are missing), and its use is, therefore, not recommended. When more than one test is required to reject the null hypothesis of no changepoint, the number of detected changepoints is reduced proportionately less than the number of false alarms in a wide variety of Monte Carlo simulations. Consequently, a consensus of hypothesis tests appears to improve undocumented changepoint detection skill, especially when reference series homogeneity is violated. A consensus of successive hypothesis tests using a semihierarchic splitting algorithm also compares favorably to optimal solutions, even when changepoints are not hierarchic.
G STL: the geostatistical template library in C++
NASA Astrophysics Data System (ADS)
Remy, Nicolas; Shtuka, Arben; Levy, Bruno; Caers, Jef
2002-10-01
The development of geostatistics has been mostly accomplished by application-oriented engineers in the past 20 years. The focus on concrete applications gave birth to many algorithms and computer programs designed to address different issues, such as estimating or simulating a variable while possibly accounting for secondary information such as seismic data, or integrating geological and geometrical data. At the core of any geostatistical data integration methodology is a well-designed algorithm. Yet, despite their obvious differences, all these algorithms share many commonalities on which to build a geostatistics programming library, lest the resulting library is poorly reusable and difficult to expand. Building on this observation, we design a comprehensive, yet flexible and easily reusable library of geostatistics algorithms in C++. The recent advent of the generic programming paradigm allows us elegantly to express the commonalities of the geostatistical algorithms into computer code. Generic programming, also referred to as "programming with concepts", provides a high level of abstraction without loss of efficiency. This last point is a major gain over object-oriented programming which often trades efficiency for abstraction. It is not enough for a numerical library to be reusable, it also has to be fast. Because generic programming is "programming with concepts", the essential step in the library design is the careful identification and thorough definition of these concepts shared by most geostatistical algorithms. Building on these definitions, a generic and expandable code can be developed. To show the advantages of such a generic library, we use G STL to build two sequential simulation programs working on two different types of grids—a surface with faults and an unstructured grid—without requiring any change to the G STL code.
Zeng, Yaohui; Singh, Sachinkumar; Wang, Kai
2017-01-01
Abstract Pharmacodynamic studies that use methacholine challenge to assess bioequivalence of generic and innovator albuterol formulations are generally designed per published Food and Drug Administration guidance, with 3 reference doses and 1 test dose (3‐by‐1 design). These studies are challenging and expensive to conduct, typically requiring large sample sizes. We proposed 14 modified study designs as alternatives to the Food and Drug Administration–recommended 3‐by‐1 design, hypothesizing that adding reference and/or test doses would reduce sample size and cost. We used Monte Carlo simulation to estimate sample size. Simulation inputs were selected based on published studies and our own experience with this type of trial. We also estimated effects of these modified study designs on study cost. Most of these altered designs reduced sample size and cost relative to the 3‐by‐1 design, some decreasing cost by more than 40%. The most effective single study dose to add was 180 μg of test formulation, which resulted in an estimated 30% relative cost reduction. Adding a single test dose of 90 μg was less effective, producing only a 13% cost reduction. Adding a lone reference dose of either 180, 270, or 360 μg yielded little benefit (less than 10% cost reduction), whereas adding 720 μg resulted in a 19% cost reduction. Of the 14 study design modifications we evaluated, the most effective was addition of both a 90‐μg test dose and a 720‐μg reference dose (42% cost reduction). Combining a 180‐μg test dose and a 720‐μg reference dose produced an estimated 36% cost reduction. PMID:29281130
Tzafetas, Menelaos; Mitra, Anita; Kalliala, Ilkka; Lever, Sarah; Fotopoulou, Christina; Farthing, Alan; Smith, John Richard; Martin-Hirsch, Pierre; Paraskevaidis, Evangelos; Kyrgiou, Maria
2018-06-01
To explore current practice in fertility-sparing surgery for cervical cancer in the UK. A web-based structured questionnaire was designed and circulated to all members of the British Gynaecological Cancer Society. From 111 recipients, a total of 49 responses were collected. The majority of centres treated between 20-29 cases of invasive cervical cancer surgically (21/49, 42.9%) and performed between 0-5 cases of radical trachelectomy annually (29/49, 59.2%). The vaginal approach was the one most commonly used and was offered by almost half of the centres (21/49, 42.9%); laparoscopic techniques were offered in 13 (13/49, 26.6%). The responses were divided as to whether these cases should have been referred to supra-regional centres (25/49, 51.0%). With the use of Human Papillomavirus vaccination leading to a projected decrease in the number of cervical cancer incidence, patients may need to be referred to supraregional centres in the future. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Stability and Performance Metrics for Adaptive Flight Control
NASA Technical Reports Server (NTRS)
Stepanyan, Vahram; Krishnakumar, Kalmanje; Nguyen, Nhan; VanEykeren, Luarens
2009-01-01
This paper addresses the problem of verifying adaptive control techniques for enabling safe flight in the presence of adverse conditions. Since the adaptive systems are non-linear by design, the existing control verification metrics are not applicable to adaptive controllers. Moreover, these systems are in general highly uncertain. Hence, the system's characteristics cannot be evaluated by relying on the available dynamical models. This necessitates the development of control verification metrics based on the system's input-output information. For this point of view, a set of metrics is introduced that compares the uncertain aircraft's input-output behavior under the action of an adaptive controller to that of a closed-loop linear reference model to be followed by the aircraft. This reference model is constructed for each specific maneuver using the exact aerodynamic and mass properties of the aircraft to meet the stability and performance requirements commonly accepted in flight control. The proposed metrics are unified in the sense that they are model independent and not restricted to any specific adaptive control methods. As an example, we present simulation results for a wing damaged generic transport aircraft with several existing adaptive controllers.
Development of a structured sensory honey analysis: application to artisanal Madrid honeys.
González, M M; de Lorenzo, C; Pérez, R A
2010-02-01
In this work a methodology to evaluate the sensory properties of honeys has been developed. The sensory analysis was carried out by means of a quantitative descriptive analysis (QDA) method, based on several reference scales, for the coverage of the designed range for each descriptor. The peculiarity of this sensory analysis is that the reference scales have been constituted by common foodstuffs agreed upon by consensus of the panel. The main sensory attributes evaluated in the analyses were: adhesiveness, viscosity, bitterness, aroma, sweetness, acidity, color and granularity. Both the intensity and persistence of honey aromas have also been estimated, together with the classification of the identified aromatic attributes into different groups. The method was applied to 55 artisanal honeys from Madrid (Spain) with the following results: (i) the developed sensory profile sheet allowed a satisfactory description of Madrid honeys; (ii) correlations between sensory attributes of three broad groups of Madrid honeys were obtained and (iii) aroma persistence, sweetness, bitterness, color and granularity appeared as the main sensorial characteristics of honey with discrimination power between floral and honeydew honeys.
Khan, Rishi L; Gonye, Gregory E; Gao, Guang; Schwaber, James S
2006-01-01
Background Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs™. Results We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. Conclusion Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in combination with reference designs enable systems biology microarray experiments of small physiologically relevant changes. PMID:16677381
Multiparameter optimization of mammography: an update
NASA Astrophysics Data System (ADS)
Jafroudi, Hamid; Muntz, E. P.; Jennings, Robert J.
1994-05-01
Previously in this forum we have reported the application of multiparameter optimization techniques to the design of a minimum dose mammography system. The approach used a reference system to define the physical imaging performance required and the dose to which the dose for the optimized system should be compared. During the course of implementing the resulting design in hardware suitable for laboratory testing, the state of the art in mammographic imaging changed, so that the original reference system, which did not have a grid, was no longer appropriate. A reference system with a grid was selected in response to this change, and at the same time the optimization procedure was modified, to make it more general and to facilitate study of the optimized design under a variety of conditions. We report the changes in the procedure, and the results obtained using the revised procedure and the up- to-date reference system. Our results, which are supported by laboratory measurements, indicate that the optimized design can image small objects as well as the reference system using only about 30% of the dose required by the reference system. Hardware meeting the specification produced by the optimization procedure and suitable for clinical use is currently under evaluation in the Diagnostic Radiology Department at the Clinical Center, NH.
Interface of Linguistic and Visual Information During Audience Design.
Fukumura, Kumiko
2015-08-01
Evidence suggests that speakers can take account of the addressee's needs when referring. However, what representations drive the speaker's audience design has been less clear. This study aims to go beyond previous studies by investigating the interplay between the visual and linguistic context during audience design. Speakers repeated subordinate descriptions (e.g., firefighter) given in the prior linguistic context less and used basic-level descriptions (e.g., man) more when the addressee did not hear the linguistic context than when s/he did. But crucially, this effect happened only when the referent lacked the visual attributes associated with the expressions (e.g., the referent was in plain clothes rather than in a firefighter uniform), so there was no other contextual cue available for the identification of the referent. This suggests that speakers flexibly use different contextual cues to help their addressee map the referring expression onto the intended referent. In addition, speakers used fewer pronouns when the addressee did not hear the linguistic antecedent than when s/he did. This suggests that although speakers may be egocentric during anaphoric reference (Fukumura & Van Gompel, 2012), they can cooperatively avoid pronouns when the linguistic antecedents were not shared with their addressee during initial reference. © 2014 Cognitive Science Society, Inc.
Predictor-Based Model Reference Adaptive Control
NASA Technical Reports Server (NTRS)
Lavretsky, Eugene; Gadient, Ross; Gregory, Irene M.
2009-01-01
This paper is devoted to robust, Predictor-based Model Reference Adaptive Control (PMRAC) design. The proposed adaptive system is compared with the now-classical Model Reference Adaptive Control (MRAC) architecture. Simulation examples are presented. Numerical evidence indicates that the proposed PMRAC tracking architecture has better than MRAC transient characteristics. In this paper, we presented a state-predictor based direct adaptive tracking design methodology for multi-input dynamical systems, with partially known dynamics. Efficiency of the design was demonstrated using short period dynamics of an aircraft. Formal proof of the reported PMRAC benefits constitute future research and will be reported elsewhere.
Pan, Haitao; Yuan, Ying; Xia, Jielai
2017-11-01
A biosimilar refers to a follow-on biologic intended to be approved for marketing based on biosimilarity to an existing patented biological product (i.e., the reference product). To develop a biosimilar product, it is essential to demonstrate biosimilarity between the follow-on biologic and the reference product, typically through two-arm randomization trials. We propose a Bayesian adaptive design for trials to evaluate biosimilar products. To take advantage of the abundant historical data on the efficacy of the reference product that is typically available at the time a biosimilar product is developed, we propose the calibrated power prior, which allows our design to adaptively borrow information from the historical data according to the congruence between the historical data and the new data collected from the current trial. We propose a new measure, the Bayesian biosimilarity index, to measure the similarity between the biosimilar and the reference product. During the trial, we evaluate the Bayesian biosimilarity index in a group sequential fashion based on the accumulating interim data, and stop the trial early once there is enough information to conclude or reject the similarity. Extensive simulation studies show that the proposed design has higher power than traditional designs. We applied the proposed design to a biosimilar trial for treating rheumatoid arthritis.
ERIC Educational Resources Information Center
Bell, James D.
In view of the dramatic increase in the numbers of laws and lawsuits since the 1960s, teachers must become aware of the privacy considerations and potential legal problems that may arise when writing a letter of recommendation or giving a verbal reference. They should become familiar with present common law doctrine and recent legislation…
Silva, Luci Meire Pereira da; Muccioli, Cristina; Oliveira, Filipe de; Arantes, Tiago Eugênio; Gonzaga, Lucas Renó; Nakanami, Célia Regina
2013-01-01
To identify the frequency and causes of uveitis leading to visual impairment in patients referred to the Low Vision Service - Department of Ophthalmology - UNIFESP, over a twenty years period. In a retrospective study, medical records of 5,461 patients were reviewed. Data from the first clinical evaluation at the Low Vision Service were collected, patient's age, gender and cause of visual impairment were analyzed. Patients with uveitis had their chart reviewed for anatomical classification and clinical diagnosis. The mean age of the patients referred to the Low Vision Service was 42.86 years and the mean age of patients with uveitis diagnosis was 25.51 years. Retinal disorders were the most common cause of visual impairment (N=2,835 patients; 51.9%) followed by uveitis (862 patients, 15.7%). Uveitis was posterior in 792 patients (91.9% of uveitis) and toxoplasmosis was the most common diagnosis (765 patients, 88.7%). In our study, uveitis represents the second cause of visual impairment in patients referred for visual rehabilitation and toxoplasmic retinochoroiditis was the most common clinical diagnosis. It affects a young working age population with a relevant social and economic impact, but the early diagnosis and treatment can improve the quality of life of these patients.
Deliberato, Débora; Jennische, Margareta; Oxley, Judith; Nunes, Leila Regina d'Oliveira de Paula; Walter, Cátia Crivelenti de Figueiredo; Massaro, Munique; Almeida, Maria Amélia; Stadskleiv, Kristine; Basil, Carmen; Coronas, Marc; Smith, Martine; von Tetzchner, Stephen
2018-03-01
Vocabulary learning reflects the language experiences of the child, both in typical and atypical development, although the vocabulary development of children who use aided communication may differ from children who use natural speech. This study compared the performance of children using aided communication with that of peers using natural speech on two measures of vocabulary knowledge: comprehension of graphic symbols and labeling of common objects. There were 92 participants not considered intellectually disabled in the aided group. The reference group consisted of 60 participants without known disorders. The comprehension task consisted of 63 items presented individually in each participant's graphic system, together with four colored line drawings. Participants were required to indicate which drawing corresponded to the symbol. In the expressive labelling task, 20 common objects presented in drawings had to be named. Both groups indicated the correct drawing for most of the items in the comprehension tasks, with a small advantage for the reference group. The reference group named most objects quickly and accurately, demonstrating that the objects were common and easily named. The aided language group named the majority correctly and in addition used a variety of naming strategies; they required more time than the reference group. The results give insights into lexical processing in aided communication and may have implications for aided language intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kautsky, Mark; Findlay, Richard C.; Hodges, Rex A.
2013-07-01
Managing technical references for projects that have long histories is hampered by the large collection of documents, each of which might contain discrete pieces of information relevant to the site conceptual model. A database application has been designed to improve the efficiency of retrieving technical information for a project. Although many databases are currently used for accessing analytical and geo-referenced data, applications designed specifically to manage technical reference material for projects are scarce. Retrieving site data from the array of available references becomes an increasingly inefficient use of labor. The electronic-Knowledge Information Tool (e-KIT) is designed as a project-level resourcemore » to access and communicate technical information. The e-KIT is a living tool that grows as new information becomes available, and its value to the project increases as the volume of site information increases. Having all references assembled in one location with complete reference citations and links to elements of the site conceptual model offers a way to enhance communication with outside groups. The published and unpublished references are incorporated into the e-KIT, while the compendium of references serves as a complete bibliography for the project. (authors)« less
A Guide to the Common Diatoms at Water Pollution Surveillance System Stations.
ERIC Educational Resources Information Center
Weber, Cornelius I.
This guide was developed by the United States Environmental Protection Agency (EPA) as a taxonomic reference for the identification of diatoms. The taxonomic information included consists of a generic key to the common genera of diatoms, a section illustrating 164 diatom species representing 43 common genera found at the Water Pollution…
Single-Case Designs and Qualitative Methods: Applying a Mixed Methods Research Perspective
ERIC Educational Resources Information Center
Hitchcock, John H.; Nastasi, Bonnie K.; Summerville, Meredith
2010-01-01
The purpose of this conceptual paper is to describe a design that mixes single-case (sometimes referred to as single-subject) and qualitative methods, hereafter referred to as a single-case mixed methods design (SCD-MM). Minimal attention has been given to the topic of applying qualitative methods to SCD work in the literature. These two…
Zou, An-Min; Kumar, Krishna Dev
2012-07-01
This brief considers the attitude coordination control problem for spacecraft formation flying when only a subset of the group members has access to the common reference attitude. A quaternion-based distributed attitude coordination control scheme is proposed with consideration of the input saturation and with the aid of the sliding-mode observer, separation principle theorem, Chebyshev neural networks, smooth projection algorithm, and robust control technique. Using graph theory and a Lyapunov-based approach, it is shown that the distributed controller can guarantee the attitude of all spacecraft to converge to a common time-varying reference attitude when the reference attitude is available only to a portion of the group of spacecraft. Numerical simulations are presented to demonstrate the performance of the proposed distributed controller.
Transitioning from conceptual design to construction performance specification
NASA Astrophysics Data System (ADS)
Jeffers, Paul; Warner, Mark; Craig, Simon; Hubbard, Robert; Marshall, Heather
2012-09-01
On successful completion of a conceptual design review by a funding agency or customer, there is a transition phase before construction contracts can be placed. The nature of this transition phase depends on the Project's approach to construction and the particular subsystem being considered. There are generically two approaches; project retention of design authority and issuance of build to print contracts, or issuance of subsystem performance specifications with controlled interfaces. This paper relates to the latter where a proof of concept (conceptual or reference design) is translated into performance based sub-system specifications for competitive tender. This translation is not a straightforward process and there are a number of different issues to consider in the process. This paper deals with primarily the Telescope mount and Enclosure subsystems. The main subjects considered in this paper are: • Typical status of design at Conceptual Design Review compared with the desired status of Specifications and Interface Control Documents at Request for Quotation. • Options for capture and tracking of system requirements flow down from science / operating requirements and sub-system requirements, and functional requirements derived from reference design. • Requirements that may come specifically from the contracting approach. • Methods for effective use of reference design work without compromising a performance based specification. • Management of project team's expectation relating to design. • Effects on cost estimates from reference design to actual. This paper is based on experience and lessons learned through this process on both the VISTA and the ATST projects.
Adaptive Control with Reference Model Modification
NASA Technical Reports Server (NTRS)
Stepanyan, Vahram; Krishnakumar, Kalmanje
2012-01-01
This paper presents a modification of the conventional model reference adaptive control (MRAC) architecture in order to improve transient performance of the input and output signals of uncertain systems. A simple modification of the reference model is proposed by feeding back the tracking error signal. It is shown that the proposed approach guarantees tracking of the given reference command and the reference control signal (one that would be designed if the system were known) not only asymptotically but also in transient. Moreover, it prevents generation of high frequency oscillations, which are unavoidable in conventional MRAC systems for large adaptation rates. The provided design guideline makes it possible to track a reference commands of any magnitude from any initial position without re-tuning. The benefits of the method are demonstrated with a simulation example
Three-Dimensional Imaging by Self-Reference Single-Channel Digital Incoherent Holography
Rosen, Joseph; Kelner, Roy
2016-01-01
Digital holography offers a reliable and fast method to image a three-dimensional scene from a single perspective. This article reviews recent developments of self-reference single-channel incoherent hologram recorders. Hologram recorders in which both interfering beams, commonly referred to as the signal and the reference beams, originate from the same observed objects are considered as self-reference systems. Moreover, the hologram recorders reviewed herein are configured in a setup of a single channel interferometer. This unique configuration is achieved through the use of one or more spatial light modulators. PMID:28757811
Advanced Robotics for In-Space Vehicle Processing
NASA Technical Reports Server (NTRS)
Smith, Jeffrey H.; Estus, Jay; Heneghan, Cate; Bosley, John
1990-01-01
An analysis of spaceborne vehicle processing is described. Generic crew-EVA tasks are presented for a specific vehicle, the orbital maneuvering vehicle (OMV), with general implications to other on-orbit vehicles. The OMV is examined with respect to both servicing and maintenance. Crew-EVA activities are presented by task and mapped to a common set of generic crew-EVA primitives to identify high-demand areas for telerobot services. Similarly, a set of telerobot primitives is presented that can be used to model telerobot actions for alternative telerobot reference configurations. The telerobot primitives are tied to technologies and used for composting telerobot operations for an automated refueling scenario. Telerobotics technology issues and design accomodation guidelines (hooks and scars) for the Space Station Freedom are described.
76 FR 15216 - Security Zones; Cruise Ships, Port of San Diego, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-21
...The Coast Guard is amending its regulations for Security Zones; Cruise Ships, Port of San Diego, California, by providing a common description of all security zones created by this section to encompass only navigable waters within a 100 yard radius around any cruise ship that is located within the San Diego port area landward of the sea buoys bounding the Port of San Diego. This final rule removes a reference to shore area that is no longer necessary to provide for the safety of the cruise ship, vessels, and users of the waterway. Entry into these security zones will be prohibited unless specifically authorized by the Captain of the Port (COTP) San Diego, or a COTP designated representative.
He, Wei; Xie, Yanming; Wang, Yongyan
2011-10-01
The purpose of post-marketing Chinese medicine re-evaluation is to identify Chinese medicine clinical indications, while designing scientific and rational of Chinese medicine symptoms items are important to the result of symptoms re-evaluation. This study give screening of traditional Chinese medicine(TCM) symptoms item of post-marketing medicine Xuezhikang re-evaluation as example that reference to principle dyslipidemia clinical research, academic dissertations, Xuezhikang directions, clinical expert practice experience etc. while standardization those symptom names and screening 41 dyslipidemia common symptoms. Furthermore, this paper discuss about the accoerdance and announcements when screening symptoms item, so as to providing a research thread to manufacture PRO chart for post-marketing medicine re-evaluation.
Epidermal differential impedance sensor for conformal skin hydration monitoring.
Huang, Xian; Yeo, Woon-Hong; Liu, Yuhao; Rogers, John A
2012-12-01
We present the design and use of an ultrathin, stretchable sensor system capable of conformal lamination onto the skin, for precision measurement and spatial mapping of levels of hydration. This device, which we refer to as a class of 'epidermal electronics' due to its 'skin-like' construction and mode of intimate integration with the body, contains miniaturized arrays of impedance-measurement electrodes arranged in a differential configuration to compensate for common-mode disturbances. Experimental results obtained with different frequencies and sensor geometries demonstrate excellent precision and accuracy, as benchmarked against conventional, commercial devices. The reversible, non-invasive soft contact of this device with the skin makes its operation appealing for applications ranging from skin care, to athletic monitoring to health/wellness assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dejong, G.F.; Waltz, D.L.
1983-01-01
This paper treats in some detail the problem of designing mechanisms that will allow one to deal with two types of novel language: (1) text requiring scheme learning; and (2) the understanding of novel metaphorical use of verbs. Schema learning is addressed by four types of processes: scheme composition, secondary effect elevation, schema alteration, and volitionalization. The processing of novel metaphors depends on a decompositional analysis of verbs into event shape diagrams, along with a matching process that uses semantic marker-like information, to construct novel meaning structures. The examples described have been chosen to be types that occur commonly, somore » that rules that are needed to understand them can also be used to understand a much wider range of novel language. 38 references.« less
Field-design optimization with triangular heliostat pods
NASA Astrophysics Data System (ADS)
Domínguez-Bravo, Carmen-Ana; Bode, Sebastian-James; Heiming, Gregor; Richter, Pascal; Carrizosa, Emilio; Fernández-Cara, Enrique; Frank, Martin; Gauché, Paul
2016-05-01
In this paper the optimization of a heliostat field with triangular heliostat pods is addressed. The use of structures which allow the combination of several heliostats into a common pod system aims to reduce the high costs associated with the heliostat field and therefore reduces the Levelized Cost of Electricity value. A pattern-based algorithm and two pattern-free algorithms are adapted to handle the field layout problem with triangular heliostat pods. Under the Helio100 project in South Africa, a new small-scale Solar Power Tower plant has been recently constructed. The Helio100 plant has 20 triangular pods (each with 6 heliostats) whose positions follow a linear pattern. The obtained field layouts after optimization are compared against the reference field Helio100.
Freeman, Kathleen P; Baral, Randolph M; Dhand, Navneet K; Nielsen, Søren Saxmose; Jensen, Asger L
2017-06-01
The recent creation of a veterinary clinical pathology biologic variation website has highlighted the need to provide recommendations for future studies of biologic variation in animals in order to help standardize and improve the quality of published information and to facilitate review and selection of publications as standard references. The following recommendations are provided in the format and order commonly found in veterinary publications. A checklist is provided to aid in planning, implementing, and evaluating veterinary studies on biologic variation (Appendix S1). These recommendations provide a valuable resource for clinicians, laboratorians, and researchers interested in conducting studies of biologic variation and in determining the quality of studies of biologic variation in veterinary laboratory testing. © 2017 American Society for Veterinary Clinical Pathology.
Reusing models of actors and services in smart homecare to improve sustainability.
Walderhaug, Ståle; Stav, Erlend; Mikalsen, Marius
2008-01-01
Industrial countries are faced with a growing elderly population. Homecare systems with assistive smart house technology enable elderly to live independently at home. Development of such smart home care systems is complex and expensive and there is no common reference model that can facilitate service reuse. This paper proposes reusable actor and service models based on a model-driven development process where end user organizations and domain healthcare experts from four European countries have been involved. The models, specified using UML can be reused actively as assets in the system design and development process and can reduce development costs, and improve interoperability and sustainability of systems. The models are being evaluated in the European IST project MPOWER.
Applications of mixed-methods methodology in clinical pharmacy research.
Hadi, Muhammad Abdul; Closs, S José
2016-06-01
Introduction Mixed-methods methodology, as the name suggests refers to mixing of elements of both qualitative and quantitative methodologies in a single study. In the past decade, mixed-methods methodology has gained popularity among healthcare researchers as it promises to bring together the strengths of both qualitative and quantitative approaches. Methodology A number of mixed-methods designs are available in the literature and the four most commonly used designs in healthcare research are: the convergent parallel design, the embedded design, the exploratory design, and the explanatory design. Each has its own unique advantages, challenges and procedures and selection of a particular design should be guided by the research question. Guidance on designing, conducting and reporting mixed-methods research is available in the literature, so it is advisable to adhere to this to ensure methodological rigour. When to use it is best suited when the research questions require: triangulating findings from different methodologies to explain a single phenomenon; clarifying the results of one method using another method; informing the design of one method based on the findings of another method, development of a scale/questionnaire and answering different research questions within a single study. Two case studies have been presented to illustrate possible applications of mixed-methods methodology. Limitations Possessing the necessary knowledge and skills to undertake qualitative and quantitative data collection, analysis, interpretation and integration remains the biggest challenge for researchers conducting mixed-methods studies. Sequential study designs are often time consuming, being in two (or more) phases whereas concurrent study designs may require more than one data collector to collect both qualitative and quantitative data at the same time.
Lee, Hyun Kun; Hwang, In Hong; Kim, Soo Young; Pyo, Se Young
2014-05-01
Because there is no specific treatment for the common cold, many previous studies have focused on prevention of the common cold. There were some studies reporting that regular, moderate-intensity exercise increases immunity and prevents the common cold. We conducted a meta-analysis to determine the effects of exercise on prevention of the common cold. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), CINAHL for studies released through June 2013. We manually searched the references. Two authors independently extracted the data. To assess the risk of bias of included literature, Cochrane Collaboration's tool for assessing risk of bias was used. Review Manager ver. 5.2 (RevMan, Cochrane Collaboration) was used for statistical analysis. Four randomized controlled trials were identified. A total of 281 participants, 134 in the exercise group and 147 in the control group, were included. The effect of exercise on the prevention of the common cold had a relative risk (RR) of 0.73 (95% confidence interval [CI], 0.56 to 0.95; I(2) = 7%). The mean difference of mean illness days between exercise group and control group was -3.50 (95% CI, -6.06 to -0.94; I(2) = 93%). In the subgroup analysis, the RR of under 16 weeks exercise was 0.79 (95% CI, 0.58 to 1.08). In this meta-analysis, regular, moderate-intensity exercise may have an effect on the prevention of the common cold. But numbers of included studies and participants were too small and quality of included studies was relatively poor. Subsequent well-designed studies with larger sample size are needed to clarify the association.
The Peer Reference Counseling Program at Odum Library. Training Manual.
ERIC Educational Resources Information Center
Lawrence, Tamiko Danielle; Thomas, Susan; Winston, Mark
The Peer Reference Counseling Program at Valdosta State University (Georgia) is a program designed to provide students with a unique opportunity to work at the Reference Desk at Odum Library. This program employs minority students and trains them to work at the Reference Desk answering basic reference questions and utilizing as well as…
78 FR 56150 - Airworthiness Directives; Piper Aircraft, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-12
..., PA-46-350P, PA-46R-350T, and PA-46-500TP airplanes. There is an incorrect reference to a paragraph designation, four instances of an incorrect reference to the paragraph in the service bulletin that references... instances of an incorrect reference to the paragraph in the service bulletin that references an...
Econometrics and Psychometrics: A Survey of Communalities
ERIC Educational Resources Information Center
Goldberger, Arthur S.
1971-01-01
Several themes which are common to both econometrics and psychometrics are surveyed. The themes are illustrated by reference to permanent income hypotheses, simultaneous equation models, adaptive expectations and partial adjustment schemes, and by reference to test score theory, factor analysis, and time-series models. (Author)
A challenge in environmental passive sampling is determining when equilibrium is achieved between the sampler, target contaminants, and environmental phases. A common approach is the use of performance reference compounds (PRCs) to indicate degree of equilibrium. One logistical...
Assessment of seismic design response factors of concrete wall buildings
NASA Astrophysics Data System (ADS)
Mwafy, Aman
2011-03-01
To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.
Mental health issues among college students: who gets referred for psychopharmacology evaluation?
Kirsch, Daniel J; Doerfler, Leonard A; Truong, Debbie
2015-01-01
To describe diagnostic and psychotropic medication prescription characteristics among college students referred by college counseling centers for psychopharmacologic evaluation. Participants were 540 college students referred by 6 college counseling centers in Massachusetts between November 2005 and May 2011. Students completed self-report measures of depression, anxiety, suicidal ideation and attempts, and substance use. Information regarding DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, 4th edition) diagnosis, previous history of medication prescription, and current psychotropic medication(s) prescribed by the consulting psychiatrist was obtained from medical records. Depression, anxiety, and attention-deficit/hyperactivity disorder (ADHD) were the most common psychiatric problems identified in students. Half of these students had been prescribed mediation prior to evaluation. Antidepressant medication was the most frequently prescribed medication. A large proportion of students reported previous thoughts of suicide, and 12% had made at least 1 suicide attempt. Depression, anxiety, and ADHD are common among students referred by college counseling centers for medication evaluation and treatment.
Validation of endogenous reference genes for qRT-PCR analysis of human visceral adipose samples
2010-01-01
Background Given the epidemic proportions of obesity worldwide and the concurrent prevalence of metabolic syndrome, there is an urgent need for better understanding the underlying mechanisms of metabolic syndrome, in particular, the gene expression differences which may participate in obesity, insulin resistance and the associated series of chronic liver conditions. Real-time PCR (qRT-PCR) is the standard method for studying changes in relative gene expression in different tissues and experimental conditions. However, variations in amount of starting material, enzymatic efficiency and presence of inhibitors can lead to quantification errors. Hence the need for accurate data normalization is vital. Among several known strategies for data normalization, the use of reference genes as an internal control is the most common approach. Recent studies have shown that both obesity and presence of insulin resistance influence an expression of commonly used reference genes in omental fat. In this study we validated candidate reference genes suitable for qRT-PCR profiling experiments using visceral adipose samples from obese and lean individuals. Results Cross-validation of expression stability of eight selected reference genes using three popular algorithms, GeNorm, NormFinder and BestKeeper found ACTB and RPII as most stable reference genes. Conclusions We recommend ACTB and RPII as stable reference genes most suitable for gene expression studies of human visceral adipose tissue. The use of these genes as a reference pair may further enhance the robustness of qRT-PCR in this model system. PMID:20492695
Validation of endogenous reference genes for qRT-PCR analysis of human visceral adipose samples.
Mehta, Rohini; Birerdinc, Aybike; Hossain, Noreen; Afendy, Arian; Chandhoke, Vikas; Younossi, Zobair; Baranova, Ancha
2010-05-21
Given the epidemic proportions of obesity worldwide and the concurrent prevalence of metabolic syndrome, there is an urgent need for better understanding the underlying mechanisms of metabolic syndrome, in particular, the gene expression differences which may participate in obesity, insulin resistance and the associated series of chronic liver conditions. Real-time PCR (qRT-PCR) is the standard method for studying changes in relative gene expression in different tissues and experimental conditions. However, variations in amount of starting material, enzymatic efficiency and presence of inhibitors can lead to quantification errors. Hence the need for accurate data normalization is vital. Among several known strategies for data normalization, the use of reference genes as an internal control is the most common approach. Recent studies have shown that both obesity and presence of insulin resistance influence an expression of commonly used reference genes in omental fat. In this study we validated candidate reference genes suitable for qRT-PCR profiling experiments using visceral adipose samples from obese and lean individuals. Cross-validation of expression stability of eight selected reference genes using three popular algorithms, GeNorm, NormFinder and BestKeeper found ACTB and RPII as most stable reference genes. We recommend ACTB and RPII as stable reference genes most suitable for gene expression studies of human visceral adipose tissue. The use of these genes as a reference pair may further enhance the robustness of qRT-PCR in this model system.
Hao, Xinyuan; Horvath, David P.; Chao, Wun S.; Yang, Yajun; Wang, Xinchao; Xiao, Bin
2014-01-01
Reliable reference selection for the accurate quantification of gene expression under various experimental conditions is a crucial step in qRT-PCR normalization. To date, only a few housekeeping genes have been identified and used as reference genes in tea plant. The validity of those reference genes are not clear since their expression stabilities have not been rigorously examined. To identify more appropriate reference genes for qRT-PCR studies on tea plant, we examined the expression stability of 11 candidate reference genes from three different sources: the orthologs of Arabidopsis traditional reference genes and stably expressed genes identified from whole-genome GeneChip studies, together with three housekeeping gene commonly used in tea plant research. We evaluated the transcript levels of these genes in 94 experimental samples. The expression stabilities of these 11 genes were ranked using four different computation programs including geNorm, Normfinder, BestKeeper, and the comparative ∆CT method. Results showed that the three commonly used housekeeping genes of CsTUBULIN1, CsACINT1 and Cs18S rRNA1 together with CsUBQ1 were the most unstable genes in all sample ranking order. However, CsPTB1, CsEF1, CsSAND1, CsCLATHRIN1 and CsUBC1 were the top five appropriate reference genes for qRT-PCR analysis in complex experimental conditions. PMID:25474086
Presentation of structural component designs for the family of commuter airplanes
NASA Technical Reports Server (NTRS)
Russell, Mark; Haddad, Raphael; Creighton, Tom; Hendrich, Louis; Hensley, Doug; Morgan, Louise; Swift, Jerry
1987-01-01
The purpose is to present the implementation of structural commonality in the family of commuter airplanes. One of the main goals is implementation of structural commonality to as high a degree as possible. The structural layouts of those parts of the airplanes in which commonality is possible with all members of the family will be presented. The following airplane sections, which are common on all of the airplanes in the family, will be presented: common nose cone design; common wing torque box design; and common tail cone design. A proposed production and manufacturing breakdown is described. The advantages and disadvantages of implementing structural commonality and recommendations for further work will be discussed.
The NASA Marshall Space Flight Center Earth Global Reference Atmospheric Model-2010 Version
NASA Technical Reports Server (NTRS)
Leslie, F. W.; Justus, C. G.
2011-01-01
Reference or standard atmospheric models have long been used for design and mission planning of various aerospace systems. The NASA Marshall Space Flight Center Global Reference Atmospheric Model was developed in response to the need for a design reference atmosphere that provides complete global geographical variability and complete altitude coverage (surface to orbital altitudes), as well as complete seasonal and monthly variability of the thermodynamic variables and wind components. In addition to providing the geographical, height, and monthly variation of the mean atmospheric state, it includes the ability to simulate spatial and temporal perturbations.
Salehi, Reza; Tsoi, Stephen C M; Colazo, Marcos G; Ambrose, Divakar J; Robert, Claude; Dyck, Michael K
2017-01-30
Early embryonic loss is a large contributor to infertility in cattle. Moreover, bovine becomes an interesting model to study human preimplantation embryo development due to their similar developmental process. Although genetic factors are known to affect early embryonic development, the discovery of such factors has been a serious challenge. Microarray technology allows quantitative measurement and gene expression profiling of transcript levels on a genome-wide basis. One of the main decisions that have to be made when planning a microarray experiment is whether to use a one- or two-color approach. Two-color design increases technical replication, minimizes variability, improves sensitivity and accuracy as well as allows having loop designs, defining the common reference samples. Although microarray is a powerful biological tool, there are potential pitfalls that can attenuate its power. Hence, in this technical paper we demonstrate an optimized protocol for RNA extraction, amplification, labeling, hybridization of the labeled amplified RNA to the array, array scanning and data analysis using the two-color analysis strategy.
Tao Tang; Wang Ling Goh; Lei Yao; Jia Hao Cheong; Yuan Gao
2017-07-01
This paper describes an integrated multichannel neural recording analog front end (AFE) with a novel area-efficient driven right leg (DRL) circuit to improve the system common mode rejection ratio (CMRR). The proposed AFE consists of an AC-coupled low-noise programmable-gain amplifier, an area-efficient DRL block and a 10-bit SAR ADC. Compared to conventional DRL circuit, the proposed capacitor-less DRL design achieves 90% chip area reduction with enhanced CMRR performance, making it ideal for multichannel biomedical recording applications. The AFE circuit has been designed in a standard 0.18-μm CMOS process. Post-layout simulation results show that the AFE provides two gain settings of 54dB/60dB while consuming 1 μA per channel under a supply voltage of 1 V. The input-referred noise of the AFE integrated from 1 Hz to 10k Hz is only 4 μVrms and the CMRR is 110 dB.
Results from the First Two Flights of the Static Computer Memory Integrity Testing Experiment
NASA Technical Reports Server (NTRS)
Hancock, Thomas M., III
1999-01-01
This paper details the scientific objectives, experiment design, data collection method, and post flight analysis following the first two flights of the Static Computer Memory Integrity Testing (SCMIT) experiment. SCMIT is designed to detect soft-event upsets in passive magnetic memory. A soft-event upset is a change in the logic state of active or passive forms of magnetic memory, commonly referred to as a "Bitflip". In its mildest form a soft-event upset can cause software exceptions, unexpected events, start spacecraft safeing (ending data collection) or corrupted fault protection and error recovery capabilities. In it's most severe form loss of mission or spacecraft can occur. Analysis after the first flight (in 1991 during STS-40) identified possible soft-event upsets to 25% of the experiment detectors. Post flight analysis after the second flight (in 1997 on STS-87) failed to find any evidence of soft-event upsets. The SCMIT experiment is currently scheduled for a third flight in December 1999 on STS-101.
Modelling and analysis of the crush zone of a typical Australian passenger train
NASA Astrophysics Data System (ADS)
Sun, Y. Q.; Cole, C.; Dhanasekar, M.; Thambiratnam, D. P.
2012-07-01
In this paper, a three-dimensional nonlinear rigid body model has been developed for the investigation of the crashworthiness of a passenger train using the multibody dynamics approach. This model refers to a typical design of passenger cars and train constructs commonly used in Australia. The high-energy and low-energy crush zones of the cars and the train constructs are assumed and the data are explicitly provided in the paper. The crash scenario is limited to the train colliding on to a fixed barrier symmetrically. The simulations of a single car show that this initial design is only applicable for the crash speed of 35 km/h or lower. For higher speeds (e.g. 140 km/h), the crush lengths or crush forces or both the crush zone elements will have to be enlarged. It is generally better to increase the crush length than the crush force in order to retain the low levels of the longitudinal deceleration of the passenger cars.
Alignment of the Stanford Linear Collider Arcs: Concepts and results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitthan, R.; Bell, B.; Friedsam, H.
1987-02-01
The alignment of the Arcs for the Stanford Linear Collider at SLAC has posed problems in accelerator survey and alignment not encountered before. These problems come less from the tight tolerances of 0.1 mm, although reaching such a tight statistically defined accuracy in a controlled manner is difficult enough, but from the absence of a common reference plane for the Arcs. Traditional circular accelerators, including HERA and LEP, have been designed in one plane referenced to local gravity. For the SLC Arcs no such single plane exists. Methods and concepts developed to solve these and other problems, connected with themore » unique design of SLC, range from the first use of satellites for accelerator alignment, use of electronic laser theodolites for placement of components, computer control of the manual adjustment process, complete automation of the data flow incorporating the most advanced concepts of geodesy, strict separation of survey and alignment, to linear principal component analysis for the final statistical smoothing of the mechanical components.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, Ethan S.; Pratt, Joseph William
To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These ‘Reference Stations’ help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analysesmore » of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.« less
SSVEP recognition using common feature analysis in brain-computer interface.
Zhang, Yu; Zhou, Guoxu; Jin, Jing; Wang, Xingyu; Cichocki, Andrzej
2015-04-15
Canonical correlation analysis (CCA) has been successfully applied to steady-state visual evoked potential (SSVEP) recognition for brain-computer interface (BCI) application. Although the CCA method outperforms the traditional power spectral density analysis through multi-channel detection, it requires additionally pre-constructed reference signals of sine-cosine waves. It is likely to encounter overfitting in using a short time window since the reference signals include no features from training data. We consider that a group of electroencephalogram (EEG) data trials recorded at a certain stimulus frequency on a same subject should share some common features that may bear the real SSVEP characteristics. This study therefore proposes a common feature analysis (CFA)-based method to exploit the latent common features as natural reference signals in using correlation analysis for SSVEP recognition. Good performance of the CFA method for SSVEP recognition is validated with EEG data recorded from ten healthy subjects, in contrast to CCA and a multiway extension of CCA (MCCA). Experimental results indicate that the CFA method significantly outperformed the CCA and the MCCA methods for SSVEP recognition in using a short time window (i.e., less than 1s). The superiority of the proposed CFA method suggests it is promising for the development of a real-time SSVEP-based BCI. Copyright © 2014 Elsevier B.V. All rights reserved.
Systematic review of serum steroid reference intervals developed using mass spectrometry.
Tavita, Nevada; Greaves, Ronda F
2017-12-01
The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
37 CFR 1.78 - Claiming benefit of earlier filing date and cross-references to other applications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and cross-references to other applications. (a)(1) A nonprovisional application or international...-filed copending nonprovisional applications or international applications designating the United States... nonprovisional application or international application designating the United States of America, each prior...
Quantitative Imaging Biomarkers: A Review of Statistical Methods for Computer Algorithm Comparisons
2014-01-01
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research. PMID:24919829
Design of two-dimensional zero reference codes with cross-entropy method.
Chen, Jung-Chieh; Wen, Chao-Kai
2010-06-20
We present a cross-entropy (CE)-based method for the design of optimum two-dimensional (2D) zero reference codes (ZRCs) in order to generate a zero reference signal for a grating measurement system and achieve absolute position, a coordinate origin, or a machine home position. In the absence of diffraction effects, the 2D ZRC design problem is known as the autocorrelation approximation. Based on the properties of the autocorrelation function, the design of the 2D ZRC is first formulated as a particular combination optimization problem. The CE method is then applied to search for an optimal 2D ZRC and thus obtain the desirable zero reference signal. Computer simulation results indicate that there are 15.38% and 14.29% reductions in the second maxima value for the 16x16 grating system with n(1)=64 and the 100x100 grating system with n(1)=300, respectively, where n(1) is the number of transparent pixels, compared with those of the conventional genetic algorithm.
Estimating reliable paediatric reference intervals in clinical chemistry and haematology.
Ridefelt, Peter; Hellberg, Dan; Aldrimer, Mattias; Gustafsson, Jan
2014-01-01
Very few high-quality studies on paediatric reference intervals for general clinical chemistry and haematology analytes have been performed. Three recent prospective community-based projects utilising blood samples from healthy children in Sweden, Denmark and Canada have substantially improved the situation. The present review summarises current reference interval studies for common clinical chemistry and haematology analyses. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Simultaneously Discovering and Localizing Common Objects in Wild Images.
Wang, Zhenzhen; Yuan, Junsong
2018-09-01
Motivated by the recent success of supervised and weakly supervised common object discovery, in this paper, we move forward one step further to tackle common object discovery in a fully unsupervised way. Generally, object co-localization aims at simultaneously localizing objects of the same class across a group of images. Traditional object localization/detection usually trains specific object detectors which require bounding box annotations of object instances, or at least image-level labels to indicate the presence/absence of objects in an image. Given a collection of images without any annotations, our proposed fully unsupervised method is to simultaneously discover images that contain common objects and also localize common objects in corresponding images. Without requiring to know the total number of common objects, we formulate this unsupervised object discovery as a sub-graph mining problem from a weighted graph of object proposals, where nodes correspond to object proposals, and edges represent the similarities between neighbouring proposals. The positive images and common objects are jointly discovered by finding sub-graphs of strongly connected nodes, with each sub-graph capturing one object pattern. The optimization problem can be efficiently solved by our proposed maximal-flow-based algorithm. Instead of assuming that each image contains only one common object, our proposed solution can better address wild images where each image may contain multiple common objects or even no common object. Moreover, our proposed method can be easily tailored to the task of image retrieval in which the nodes correspond to the similarity between query and reference images. Extensive experiments on PASCAL VOC 2007 and Object Discovery data sets demonstrate that even without any supervision, our approach can discover/localize common objects of various classes in the presence of scale, view point, appearance variation, and partial occlusions. We also conduct broad experiments on image retrieval benchmarks, Holidays and Oxford5k data sets, to show that our proposed method, which considers both the similarity between query and reference images and also similarities among reference images, can help to improve the retrieval results significantly.
Development of optical surface-profiling instrumentation
NASA Astrophysics Data System (ADS)
Lin, Yao; Takacs, Peter Z.; Tsang, Thomas; Furenlid, Karen; Wang, Runwen
1992-12-01
A novel non-contact optical profiler described in this paper is designed and made for measuring the surface characteristics of optical parts. Measurements are based on a combination of an optical heterodyne technique and a precise phase measurement procedure without the need of a reference surface. A Zeeman-split He-Ne laser is employed as the light source which offers two common-path polarized beams. The frequency difference between the beams is 1.8 MHz. A special optical head is designed and fashioned as a beam splitter which contains a birefringent lens and an objective. The whole optical system is completely common- path. This allows the optical common-mode rejection technique to be applied in the system for minimizing the environmental effects in measurements such as air turbulence, vibrations and temperature variations. To keep the sample surface focused on the ordinary rays in the optical head, an astigmatic autofocus system is employed. A stepping micro-stepping system can move the optical head in the range of 25 mm with 0.1 micrometers resolution. A data acquisition system is made to control the auto-focus system, data receiving and analyses. This makes the measurement automatically while the sample is being scanned. The characteristics of the surface can be displayed on the computer screen. The theoretical and experimental analyses of the profiler are completed. The profiler measures samples with 1.1 angstroms height accuracy and 4 micrometers lateral resolution when a 40X objective is used in the optical head. The accuracy comparisons of the profiler with different objectives 5X, 10X, 20X, and 40X are shown in good agreement. The advantages of the present profiler are presented. Based on the autofocus system, the profiler optical system will be designed to mount on a large linear air-bearing slide, so that it is capable of scanning over a distance covering from 4 micrometers to 1 m.
Code of Federal Regulations, 2010 CFR
2010-04-01
... on the authority of Form CA-16. The employer should not issue a second Form CA-16. ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false May the physician designated on Form CA-16... Benefits Emergency Medical Care § 10.301 May the physician designated on Form CA-16 refer the employee to...
Code of Federal Regulations, 2011 CFR
2011-04-01
... on the authority of Form CA-16. The employer should not issue a second Form CA-16. ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false May the physician designated on Form CA-16... Benefits Emergency Medical Care § 10.301 May the physician designated on Form CA-16 refer the employee to...
Code of Federal Regulations, 2013 CFR
2013-04-01
... on the authority of Form CA-16. The employer should not issue a second Form CA-16. ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true May the physician designated on Form CA-16... Benefits Emergency Medical Care § 10.301 May the physician designated on Form CA-16 refer the employee to...
Code of Federal Regulations, 2012 CFR
2012-04-01
... on the authority of Form CA-16. The employer should not issue a second Form CA-16. ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false May the physician designated on Form CA-16... Benefits Emergency Medical Care § 10.301 May the physician designated on Form CA-16 refer the employee to...
Code of Federal Regulations, 2014 CFR
2014-04-01
... on the authority of Form CA-16. The employer should not issue a second Form CA-16. ... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true May the physician designated on Form CA-16... Benefits Emergency Medical Care § 10.301 May the physician designated on Form CA-16 refer the employee to...
Common View Time Transfer Using Worldwide GPS and DMA Monitor Stations
NASA Technical Reports Server (NTRS)
Reid, Wilson G.; McCaskill, Thomas B.; Oaks, Orville J.; Buisson, James A.; Warren, Hugh E.
1996-01-01
Analysis of the on-orbit Navstar clocks and the Global Positioning System (GPS) monitor station reference clocks is performed by the Naval Research Laboratory using both broadcast and postprocessed precise ephemerides. The precise ephemerides are produced by the Defense Mapping Agency (DMA) for each of the GPS space vehicles from pseudo-range measurements collected at five GPS and at five DMA monitor stations spaced around the world. Recently, DMA established an additional site co-located with the US Naval Observatory precise time site. The time reference for the new DMA site is the DoD Master Clock. Now, for the first time, it is possible to transfer time every 15 minutes via common view from the DoD Master Clock to the 11 GPS and DMA monitor stations. The estimated precision of a single common-view time transfer measurement taken over a 15-minute interval was between 1.4 and 2.7 nanoseconds. Using the measurements from all Navstar space vehicles in common view during the 15-minute interval, typically 3-7 space vehicles, improved the estimate of the precision to between 0.65 and 1.13 nanoseconds. The mean phase error obtained from closure of the time transfer around the world using the 11 monitor stations and the 25 space vehicle clocks over a period of 4 months had a magnitude of 31 picoseconds. Analysis of the low noise time transfer from the DoD Master Clock to each of the monitor stations yields not only the bias in the time of the reference clock, but also focuses attention on structure in the behaviour of the reference clock not previously seen. Furthermore, the time transfer provides a a uniformly sampled database of 15-minute measurements that make possible, for the first time, the direct and exhaustive computation of the frequency stability of the monitor station reference clocks. To lend perspective to the analysis, a summary is given of the discontinuities in phase and frequency that occurred in the reference clock at the Master Control Station during the period covered by the analysis.
Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie
2013-01-01
Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449
Morrison, Laurie J; Nichol, Graham; Rea, Thomas D; Christenson, Jim; Callaway, Clifton W; Stephens, Shannon; Pirrallo, Ronald G; Atkins, Dianne L; Davis, Daniel P; Idris, Ahamed H; Newgard, Craig
2008-08-01
To describe the development, design and consequent scientific implications of the Resuscitation Outcomes Consortium (ROC) population-based registry; ROC Epistry-Cardiac Arrest. The ROC Epistry--Cardiac Arrest is designed as a prospective population-based registry of all Emergency Medical Services (EMSs)-attended 9-1-1 calls for patients with out-of-hospital cardiac arrest occurring in the geographical area described by the eight US and three Canadian regions. The dataset was derived by an North American interdisciplinary steering committee. Enrolled cases include individuals of all ages who experience cardiac arrest outside the hospital, with evaluation by organized EMS personnel and: (a) attempts at external defibrillation (by lay responders or emergency personnel), or chest compressions by organized EMS personnel; (b) were pulseless but did not receive attempts to defibrillate or CPR by EMS personnel. Selected data items are categorized as mandatory or optional and undergo revisions approximately every 12 months. Where possible all definitions are referenced to existing literature. Where a common definition did not exist one was developed. Optional items include standardized CPR process data elements. It is anticipated the ROC Epistry--Cardiac Arrest will enroll between approximately 9000 and 13,500 treated all rhythm arrests and 4000 and 5000 ventricular fibrillation arrests annually and approximately 8000 EMS-attended but untreated arrests. We describe the rationale, development, design and future implications of the ROC Epistry--Cardiac Arrest. This paper will serve as the reference for subsequent ROC manuscripts and for the common data elements captured in both ROC Epistry--Cardiac Arrest and the ROC trials.
Sivell, Stephanie; Edwards, Adrian; Elwyn, Glyn; Manstead, Antony S. R.
2010-01-01
Abstract Objective To describe the evidence about factors influencing breast cancer patients’ surgery choices and the implications for designing decision support in reference to an extended Theory of Planned Behaviour (TPB) and the Common Sense Model of Illness Representations (CSM). Background A wide range of factors are known to influence the surgery choices of women diagnosed with early breast cancer facing the choice of mastectomy or breast conservation surgery with radiotherapy. However, research does not always reflect the complexities of decision making and is often atheoretical. A theoretical approach, as provided by the CSM and the TPB, could help to identify and tailor support by focusing on patients’ representations of their breast cancer and predicting surgery choices. Design Literature search and narrative synthesis of data. Synthesis Twenty‐six studies reported women’s surgery choices to be influenced by perceived clinical outcomes of surgery, appearance and body image, treatment concerns, involvement in decision making and preferences of clinicians. These factors can be mapped onto the key constructs of both the TPB and CSM and used to inform the design and development of decision support interventions to ensure accurate information is provided in areas most important to patients. Conclusions The TPB and CSM have the potential to inform the design of decision support for breast cancer patients, with accurate and clear information that avoids leading patients to make decisions they may come to regret. Further research is needed examining how the components of the extended TPB and CSM account for patients’ surgery choices. PMID:20579123