Sample records for comodulation masking release

  1. Comodulation Masking Release (CMR) in Children and the Influence of Reading Status

    ERIC Educational Resources Information Center

    Zettler, Cynthia M.; Sevcik, Rose A.; Morris, Robin D.; Clarkson, Marsha G.

    2008-01-01

    Purpose: Research suggests that children with reading disabilities (RD) have difficulty processing temporal and spectral components of sounds. Comodulation masking release (CMR) measures a listener's ability to use temporal and spectral information in noise to identify a signal. The purpose of this study was to determine whether children with RD…

  2. Effect of Otitis Media with Effusion on Comodulation Masking Release in Children.

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Grose, John H.

    1994-01-01

    This study investigated comodulation masking release (CMR) in 42 children (ages 5 to 10) with a history of otitis media with effusion (OME) and 19 control children with no history of ear disease. Results indicated that monotic CMRs were reduced in children with hearing loss due to OME and these CMRs remained abnormally small for several months.…

  3. Masking release by combined spatial and masker-fluctuation effects in the open sound field.

    PubMed

    Middlebrooks, John C

    2017-12-01

    In a complex auditory scene, signals of interest can be distinguished from masking sounds by differences in source location [spatial release from masking (SRM)] and by differences between masker-alone and masker-plus-signal envelopes. This study investigated interactions between those factors in release of masking of 700-Hz tones in an open sound field. Signal and masker sources were colocated in front of the listener, or the signal source was shifted 90° to the side. In Experiment 1, the masker contained a 25-Hz-wide on-signal band plus flanking bands having envelopes that were either mutually uncorrelated or were comodulated. Comodulation masking release (CMR) was largely independent of signal location at a higher masker sound level, but at a lower level CMR was reduced for the lateral signal location. In Experiment 2, a brief signal was positioned at the envelope maximum (peak) or minimum (dip) of a 50-Hz-wide on-signal masker. Masking was released in dip more than in peak conditions only for the 90° signal. Overall, open-field SRM was greater in magnitude than binaural masking release reported in comparable closed-field studies, and envelope-related release was somewhat weaker. Mutual enhancement of masking release by spatial and envelope-related effects tended to increase with increasing masker level.

  4. Can comodulation masking release occur when frequency changes could promote perceptual segregation of the on-frequency and flanking bands?

    PubMed

    Verhey, Jesko L; Epp, Bastian; Stasiak, Arkadiusz; Winter, Ian M

    2013-01-01

    A common characteristic of natural sounds is that the level fluctuations in different frequency regions are coherent. The ability of the auditory system to use this comodulation is shown when a sinusoidal signal is masked by a masker centred at the signal frequency (on-frequency masker, OFM) and one or more off-frequency components, commonly referred to as flanking bands (FBs). In general, the threshold of the signal masked by comodulated masker components is lower than when masked by masker components with uncorrelated envelopes or in the presence of the OFM only. This effect is commonly referred to as comodulation masking release (CMR). The present study investigates if CMR is also observed for a sinusoidal signal embedded in the OFM when the centre frequencies of the FBs are swept over time with a sweep rate of one octave per second. Both a common change of different frequencies and comodulation could serve as cues to indicate which of the stimulus components originate from one source. If the common fate of frequency components is the stronger binding cue, the sweeping FBs and the OFM with a fixed centre frequency should no longer form one auditory object and the CMR should be abolished. However, psychoacoustical results with normal-hearing listeners show that a CMR is also observed with sweeping components. The results are consistent with the hypothesis of wideband inhibition as the underlying physiological mechanism, as the CMR should only depend on the spectral position of the flanking bands relative to the inhibitory areas (as seen in physiological recordings using stationary flanking bands). Preliminary physiological results in the cochlear nucleus of the Guinea pig show that a correlate of CMR can also be found at this level of the auditory pathway with sweeping flanking bands.

  5. Comodulation masking release in an off-frequency masking paradigm.

    PubMed

    Grzeschik, Ramona; Lübken, Björn; Verhey, Jesko L

    2015-08-01

    Detection threshold of a sinusoidal signal masked by a broadband masker is lower when on- and off-frequency masker components have a correlated envelope, compared to a condition in which these masker components have different envelopes. This effect is commonly referred to as comodulation masking release (CMR). The present study investigated if there is a CMR in the absence of a masker component at the signal frequency, i.e., in an off-frequency masking paradigm. Thresholds were measured for a 500-Hz signal in the presence of a broadband masker with a spectral notch at the signal frequency. Thresholds were significantly lower for a (co-)modulated than for an unmodulated masker for all notch widths up to 400 Hz. An additional experiment showed that the particularly large CMR for the no-notch condition was due to the way the modulated masker was generated. No CMR was measured when the notched-noise masker was replaced by a pair of narrowband noises. The addition of more remote masker bands resulted in a CMR of about 3-4 dB. The notched-noise data were predicted on the basis of a modulation-filterbank model. The predictions of the narrowband noise conditions indicated that all mechanisms underlying CMR might still not be fully understood.

  6. Binaural comodulation masking release: Effects of masker interaural correlation

    PubMed Central

    Hall, Joseph W.; Buss, Emily; Grose, John H.

    2007-01-01

    Binaural detection was examined for a signal presented in a narrow band of noise centered on the on-signal masking band (OSB) or in the presence of flanking noise bands that were random or comodulated with respect to the OSB. The noise had an interaural correlation of 1.0 (No), 0.99 or 0.95. In No noise, random flanking bands worsened Sπ detection and comodulated bands improved Sπ detection for some listeners but had no effect for other listeners. For the 0.99 or 0.95 interaural correlation conditions, random flanking bands were less detrimental to Sπ detection and comodulated flanking bands improved Sπ detection for all listeners. Analyses based on signal detection theory indicated that the improvement in Sπ thresholds obtained with comodulated bands was not compatible with an optimal combination of monaural and binaural cues or to across-frequency analyses of dynamic interaural phase differences. Two accounts consistent with the improvement in Sπ thresholds in comodulated noise were (1) envelope information carried by the flanking bands improves the weighting of binaural cues associated with the signal; (2) the auditory system is sensitive to across-frequency differences in ongoing interaural correlation. PMID:17225415

  7. Physiological correlates of comodulation masking release in the mammalian ventral cochlear nucleus.

    PubMed

    Pressnitzer, D; Meddis, R; Delahaye, R; Winter, I M

    2001-08-15

    Comodulation masking release (CMR) enhances the detection of signals embedded in wideband, amplitude-modulated maskers. At least part of the CMR is attributable to across-frequency processing, however, the relative contribution of different stages in the auditory system to across-frequency processing is unknown. We have measured the responses of single units from one of the earliest stages in the ascending auditory pathway, the ventral cochlear nucleus, where across frequency processing may take place. A sinusoidally amplitude-modulated tone at the best frequency of each unit was used as a masker. A pure tone signal was added in the dips of the masker modulation (reference condition). Flanking components (FCs) were then added at frequencies remote from the unit best frequency. The FCs were pure tones amplitude modulated either in phase (comodulated) or out of phase (codeviant) with the on-frequency component. Psychophysically, this CMR paradigm reduces within-channel cues while producing an advantage of approximately 10 dB for the comodulated condition in comparison with the reference condition. Some of the recorded units showed responses consistent with perceptual CMR. The addition of the comodulated FCs produced a strong reduction in the response to the masker modulation, making the signal more salient in the poststimulus time histograms. A decision statistic based on d' showed that threshold was reached at lower signal levels for the comodulated condition than for reference or codeviant conditions. The neurons that exhibited such a behavior were mainly transient chopper or primary-like units. The results obtained from a subpopulation of transient chopper units are consistent with a possible circuit in the cochlear nucleus consisting of a wideband inhibitor contacting a narrowband cell. A computational model was used to confirm the feasibility of such a circuit.

  8. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    PubMed

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Developmental Conductive Hearing Loss Reduces Modulation Masking Release

    PubMed Central

    Chen, Yi-Wen; Sanes, Dan H.

    2016-01-01

    Hearing-impaired individuals experience difficulties in detecting or understanding speech, especially in background sounds within the same frequency range. However, normally hearing (NH) human listeners experience less difficulty detecting a target tone in background noise when the envelope of that noise is temporally gated (modulated) than when that envelope is flat across time (unmodulated). This perceptual benefit is called modulation masking release (MMR). When flanking masker energy is added well outside the frequency band of the target, and comodulated with the original modulated masker, detection thresholds improve further (MMR+). In contrast, if the flanking masker is antimodulated with the original masker, thresholds worsen (MMR−). These interactions across disparate frequency ranges are thought to require central nervous system (CNS) processing. Therefore, we explored the effect of developmental conductive hearing loss (CHL) in gerbils on MMR characteristics, as a test for putative CNS mechanisms. The detection thresholds of NH gerbils were lower in modulated noise, when compared with unmodulated noise. The addition of a comodulated flanker further improved performance, whereas an antimodulated flanker worsened performance. However, for CHL-reared gerbils, all three forms of masking release were reduced when compared with NH animals. These results suggest that developmental CHL impairs both within- and across-frequency processing and provide behavioral evidence that CNS mechanisms are affected by a peripheral hearing impairment. PMID:28215119

  10. Communication masking in marine mammals: A review and research strategy.

    PubMed

    Erbe, Christine; Reichmuth, Colleen; Cunningham, Kane; Lucke, Klaus; Dooling, Robert

    2016-02-15

    Underwater noise, whether of natural or anthropogenic origin, has the ability to interfere with the way in which marine mammals receive acoustic signals (i.e., for communication, social interaction, foraging, navigation, etc.). This phenomenon, termed auditory masking, has been well studied in humans and terrestrial vertebrates (in particular birds), but less so in marine mammals. Anthropogenic underwater noise seems to be increasing in parts of the world's oceans and concerns about associated bioacoustic effects, including masking, are growing. In this article, we review our understanding of masking in marine mammals, summarise data on marine mammal hearing as they relate to masking (including audiograms, critical ratios, critical bandwidths, and auditory integration times), discuss masking release processes of receivers (including comodulation masking release and spatial release from masking) and anti-masking strategies of signalers (e.g. Lombard effect), and set a research framework for improved assessment of potential masking in marine mammals. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Exploring the additivity of binaural and monaural masking release

    PubMed Central

    Hall, Joseph W.; Buss, Emily; Grose, John H.

    2011-01-01

    Experiment 1 examined comodulation masking release (CMR) for a 700-Hz tonal signal under conditions of NoSo (noise and signal interaurally in phase) and NoSπ (noise in phase, signal out of phase) stimulation. The baseline stimulus for CMR was either a single 24-Hz wide narrowband noise centered on the signal frequency [on-signal band (OSB)] or the OSB plus, a set of flanking noise bands having random envelopes. Masking noise was either gated or continuous. The CMR, defined with respect to either the OSB or the random noise baseline, was smaller for NoSπ than NoSo stimulation, particularly when the masker was continuous. Experiment 2 examined whether the same pattern of results would be obtained for a 2000-Hz signal frequency; the number of flanking bands was also manipulated (two versus eight). Results again showed smaller CMR for NoSπ than NoSo stimulation for both continuous and gated masking noise. The CMR was larger with eight than with two flanking bands, and this difference was greater for NoSo than NoSπ. The results of this study are compatible with serial mechanisms of binaural and monaural masking release, but they indicate that the combined masking release (binaural masking-level difference and CMR) falls short of being additive. PMID:21476663

  12. Responses of auditory-cortex neurons to structural features of natural sounds.

    PubMed

    Nelken, I; Rotman, Y; Bar Yosef, O

    1999-01-14

    Sound-processing strategies that use the highly non-random structure of natural sounds may confer evolutionary advantage to many species. Auditory processing of natural sounds has been studied almost exclusively in the context of species-specific vocalizations, although these form only a small part of the acoustic biotope. To study the relationships between properties of natural soundscapes and neuronal processing mechanisms in the auditory system, we analysed sound from a range of different environments. Here we show that for many non-animal sounds and background mixtures of animal sounds, energy in different frequency bands is coherently modulated. Co-modulation of different frequency bands in background noise facilitates the detection of tones in noise by humans, a phenomenon known as co-modulation masking release (CMR). We show that co-modulation also improves the ability of auditory-cortex neurons to detect tones in noise, and we propose that this property of auditory neurons may underlie behavioural CMR. This correspondence may represent an adaptation of the auditory system for the use of an attribute of natural sounds to facilitate real-world processing tasks.

  13. Interaural level differences do not suffice for restoring spatial release from masking in simulated cochlear implant listening.

    PubMed

    Ihlefeld, Antje; Litovsky, Ruth Y

    2012-01-01

    Spatial release from masking refers to a benefit for speech understanding. It occurs when a target talker and a masker talker are spatially separated. In those cases, speech intelligibility for target speech is typically higher than when both talkers are at the same location. In cochlear implant listeners, spatial release from masking is much reduced or absent compared with normal hearing listeners. Perhaps this reduced spatial release occurs because cochlear implant listeners cannot effectively attend to spatial cues. Three experiments examined factors that may interfere with deploying spatial attention to a target talker masked by another talker. To simulate cochlear implant listening, stimuli were vocoded with two unique features. First, we used 50-Hz low-pass filtered speech envelopes and noise carriers, strongly reducing the possibility of temporal pitch cues; second, co-modulation was imposed on target and masker utterances to enhance perceptual fusion between the two sources. Stimuli were presented over headphones. Experiments 1 and 2 presented high-fidelity spatial cues with unprocessed and vocoded speech. Experiment 3 maintained faithful long-term average interaural level differences but presented scrambled interaural time differences with vocoded speech. Results show a robust spatial release from masking in Experiments 1 and 2, and a greatly reduced spatial release in Experiment 3. Faithful long-term average interaural level differences were insufficient for producing spatial release from masking. This suggests that appropriate interaural time differences are necessary for restoring spatial release from masking, at least for a situation where there are few viable alternative segregation cues.

  14. Exploring the additivity of binaural and monaural masking release.

    PubMed

    Hall, Joseph W; Buss, Emily; Grose, John H

    2011-04-01

    Experiment 1 examined comodulation masking release (CMR) for a 700-Hz tonal signal under conditions of N(o)S(o) (noise and signal interaurally in phase) and N(o)S(π) (noise in phase, signal out of phase) stimulation. The baseline stimulus for CMR was either a single 24-Hz wide narrowband noise centered on the signal frequency [on-signal band (OSB)] or the OSB plus, a set of flanking noise bands having random envelopes. Masking noise was either gated or continuous. The CMR, defined with respect to either the OSB or the random noise baseline, was smaller for N(o)S(π) than N(o)S(o) stimulation, particularly when the masker was continuous. Experiment 2 examined whether the same pattern of results would be obtained for a 2000-Hz signal frequency; the number of flanking bands was also manipulated (two versus eight). Results again showed smaller CMR for N(o)S(π) than N(o)S(o) stimulation for both continuous and gated masking noise. The CMR was larger with eight than with two flanking bands, and this difference was greater for N(o)S(o) than N(o)S(π). The results of this study are compatible with serial mechanisms of binaural and monaural masking release, but they indicate that the combined masking release (binaural masking-level difference and CMR) falls short of being additive.

  15. Dopamine Modulates Delta-Gamma Phase-Amplitude Coupling in the Prefrontal Cortex of Behaving Rats.

    PubMed

    Andino-Pavlovsky, Victoria; Souza, Annie C; Scheffer-Teixeira, Robson; Tort, Adriano B L; Etchenique, Roberto; Ribeiro, Sidarta

    2017-01-01

    Dopamine release and phase-amplitude cross-frequency coupling (CFC) have independently been implicated in prefrontal cortex (PFC) functioning. To causally investigate whether dopamine release affects phase-amplitude comodulation between different frequencies in local field potentials (LFP) recorded from the medial PFC (mPFC) of behaving rats, we used RuBiDopa, a light-sensitive caged compound that releases the neurotransmitter dopamine when irradiated with visible light. LFP power did not change in any frequency band after the application of light-uncaged dopamine, but significantly strengthened phase-amplitude comodulation between delta and gamma oscillations. Saline did not exert significant changes, while injections of dopamine and RuBiDopa produced a slow increase in comodulation for several minutes after the injection. The results show that dopamine release in the medial PFC shifts phase-amplitude comodulation from theta-gamma to delta-gamma. Although being preliminary results due to the limitation of the low number of animals present in this study, our findings suggest that dopamine-mediated modification of the frequencies involved in comodulation could be a mechanism by which this neurotransmitter regulates functioning in mPFC.

  16. Dopamine Modulates Delta-Gamma Phase-Amplitude Coupling in the Prefrontal Cortex of Behaving Rats

    PubMed Central

    Andino-Pavlovsky, Victoria; Souza, Annie C.; Scheffer-Teixeira, Robson; Tort, Adriano B. L.; Etchenique, Roberto; Ribeiro, Sidarta

    2017-01-01

    Dopamine release and phase-amplitude cross-frequency coupling (CFC) have independently been implicated in prefrontal cortex (PFC) functioning. To causally investigate whether dopamine release affects phase-amplitude comodulation between different frequencies in local field potentials (LFP) recorded from the medial PFC (mPFC) of behaving rats, we used RuBiDopa, a light-sensitive caged compound that releases the neurotransmitter dopamine when irradiated with visible light. LFP power did not change in any frequency band after the application of light-uncaged dopamine, but significantly strengthened phase-amplitude comodulation between delta and gamma oscillations. Saline did not exert significant changes, while injections of dopamine and RuBiDopa produced a slow increase in comodulation for several minutes after the injection. The results show that dopamine release in the medial PFC shifts phase-amplitude comodulation from theta-gamma to delta-gamma. Although being preliminary results due to the limitation of the low number of animals present in this study, our findings suggest that dopamine-mediated modification of the frequencies involved in comodulation could be a mechanism by which this neurotransmitter regulates functioning in mPFC. PMID:28536507

  17. Critical ratios of beluga whales (Delphinapterus leucas) and masked signal duration.

    PubMed

    Erbe, Christine

    2008-10-01

    This article examines the masking of a complex beluga vocalization by natural and anthropogenic noise. The call consisted of six 150 ms pulses exhibiting spectral peaks between 800 Hz and 8 kHz. Comparing the spectra and spectrograms of the call and noises at detection threshold showed that the animal did not hear the entire call at threshold. It only heard parts of the call in frequency and time. From the masked hearing thresholds in broadband continuous noises, critical ratios were computed. Fletcher critical bands were narrower than either 15 or 111 of an octave at the low frequencies of the call (<2 kHz), depending on which frequency the animal cued on. From the masked hearing thresholds in intermittent noises, the audible signal duration at detection threshold was computed. The intermittent noises differed in gap length, gap number, and masking, but the total audible signal duration at threshold was the same: 660 ms. This observation supports a multiple-looks model. The two amplitude modulated noises exhibited weaker masking than the unmodulated noises hinting at a comodulation masking release.

  18. Comparison of level discrimination, increment detection, and comodulation masking release in the audio- and envelope-frequency domains

    PubMed Central

    Nelson, Paul C.; Ewert, Stephan D.; Carney, Laurel H.; Dau, Torsten

    2008-01-01

    In general, the temporal structure of stimuli must be considered to account for certain observations made in detection and masking experiments in the audio-frequency domain. Two such phenomena are (1) a heightened sensitivity to amplitude increments with a temporal fringe compared to gated level discrimination performance and (2) lower tone-in-noise detection thresholds using a modulated masker compared to those using an unmodulated masker. In the current study, translations of these two experiments were carried out to test the hypothesis that analogous cues might be used in the envelope-frequency domain. Pure-tone carrier amplitude-modulation (AM) depth-discrimination thresholds were found to be similar using both traditional gated stimuli and using a temporally modulated fringe for a fixed standard depth (ms=0.25) and a range of AM frequencies (4-64 Hz). In a second experiment, masked sinusoidal AM detection thresholds were compared in conditions with and without slow and regular fluctuations imposed on the instantaneous masker AM depth. Release from masking was obtained only for very slow masker fluctuations (less than 2 Hz). A physiologically motivated model that effectively acts as a first-order envelope change detector accounted for several, but not all, of the key aspects of the data. PMID:17471731

  19. Detecting modulated signals in modulated noise: (II) neural thresholds in the songbird forebrain.

    PubMed

    Bee, Mark A; Buschermöhle, Michael; Klump, Georg M

    2007-10-01

    Sounds in the real world fluctuate in amplitude. The vertebrate auditory system exploits patterns of amplitude fluctuations to improve signal detection in noise. One experimental paradigm demonstrating these general effects has been used in psychophysical studies of 'comodulation detection difference' (CDD). The CDD effect refers to the fact that thresholds for detecting a modulated, narrowband noise signal are lower when the envelopes of flanking bands of modulated noise are comodulated with each other, but fluctuate independently of the signal compared with conditions in which the envelopes of the signal and flanking bands are all comodulated. Here, we report results from a study of the neural correlates of CDD in European starlings (Sturnus vulgaris). We manipulated: (i) the envelope correlations between a narrowband noise signal and a masker comprised of six flanking bands of noise; (ii) the signal onset delay relative to masker onset; (iii) signal duration; and (iv) masker spectrum level. Masked detection thresholds were determined from neural responses using signal detection theory. Across conditions, the magnitude of neural CDD ranged between 2 and 8 dB, which is similar to that reported in a companion psychophysical study of starlings [U. Langemann & G.M. Klump (2007) Eur. J. Neurosci., 26, 1969-1978]. We found little evidence to suggest that neural CDD resulted from the across-channel processing of auditory grouping cues related to common envelope fluctuations and synchronous onsets between the signal and flanking bands. We discuss a within-channel model of peripheral processing that explains many of our results.

  20. Separation of musical instruments based on amplitude and frequency comodulation

    NASA Astrophysics Data System (ADS)

    Jacobson, Barry D.; Cauwenberghs, Gert; Quatieri, Thomas F.

    2002-05-01

    In previous work, amplitude comodulation was investigated as a basis for monaural source separation. Amplitude comodulation refers to similarities in amplitude envelopes of individual spectral components emitted by particular types of sources. In many types of musical instruments, amplitudes of all resonant modes rise/fall, and start/stop together during the course of normal playing. We found that under certain well-defined conditions, a mixture of constant frequency, amplitude comodulated sources can unambiguously be decomposed into its constituents on the basis of these similarities. In this work, system performance was improved by relaxing the constant frequency requirement. String instruments, for example, which are normally played with vibrato, are both amplitude and frequency comodulated sources, and could not be properly tracked under the constant frequency assumption upon which our original algorithm was based. Frequency comodulation refers to similarities in frequency variations of individual harmonics emitted by these types of sources. The analytical difficulty is in defining a representation of the source which properly tracks frequency varying components. A simple, fixed filter bank can only track an individual spectral component for the duration in which it is within the passband of one of the filters. Alternatives are therefore explored which are amenable to real-time implementation.

  1. Bilateral Functional Connectivity of the Basal Ganglia in Patients with Parkinson’s Disease and Its Modulation by Dopaminergic Treatment

    PubMed Central

    Little, Simon; Tan, Huiling; Anzak, Anam; Pogosyan, Alek; Kühn, Andrea; Brown, Peter

    2013-01-01

    Parkinson’s disease is characterised by excessive subcortical beta oscillations. However, little is known about the functional connectivity of the two basal ganglia across hemispheres and specifically the role beta plays in this. We recorded local field potentials from the subthalamic nucleus bilaterally in 23 subjects with Parkinson’s disease at rest, on and off medication. We found suppression of low beta power in response to levodopa (t22 = −4.4, p<0.001). There was significant coherence between the two sides in the beta range in 19 of the subjects. Coherence was selectively attenuated in the low beta range following levodopa (t22 = −2.7; p = 0.01). We also separately analysed amplitude co-modulation and phase synchronisation in the beta band and found significant amplitude co-modulation and phase locking values in 17 and 16 subjects respectively, off medication. There was a dissociable effect of levodopa on these measures, with a significant suppression only in low beta phase locking value (t22 = −2.8, p = 0.01) and not amplitude co-modulation. The absolute mean values of amplitude co-modulation (0.40±0.03) and phase synchronisation (0.29±0.02) off medication were, however, relatively low, suggesting that the two basal ganglia networks may have to be approached separately with independent sensing and stimulation during adaptive deep brain stimulation. In addition, our findings highlight the functional distinction between the lower and upper beta frequency ranges and between amplitude co-modulation and phase synchronization across subthalamic nuclei. PMID:24376574

  2. Masking Release in Children and Adults With Hearing Loss When Using Amplification

    PubMed Central

    McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method Sentence recognition in unmodulated noise was compared with recognition in modulated noise (masking release). Recognition was measured for participants with hearing loss using individualized amplification via the hearing-aid simulator. Results Adults with hearing loss showed greater masking release than the children with hearing loss. Average masking release was small (1 dB) and did not depend on hearing status. Masking release was comparable for slow and fast compression. Conclusions The use of amplification in this study contrasts with previous studies that did not use amplification. The results suggest that when differences in audibility are reduced, participants with hearing loss may be able to take advantage of dips in the noise levels, similar to participants with normal hearing. Although children required a more favorable signal-to-noise ratio than adults for both unmodulated and modulated noise, masking release was not statistically different. However, the ability to detect a difference may have been limited by the small amount of masking release observed. PMID:26540194

  3. Comparative modular analysis of gene expression in vertebrate organs.

    PubMed

    Piasecka, Barbara; Kutalik, Zoltán; Roux, Julien; Bergmann, Sven; Robinson-Rechavi, Marc

    2012-03-29

    The degree of conservation of gene expression between homologous organs largely remains an open question. Several recent studies reported some evidence in favor of such conservation. Most studies compute organs' similarity across all orthologous genes, whereas the expression level of many genes are not informative about organ specificity. Here, we use a modularization algorithm to overcome this limitation through the identification of inter-species co-modules of organs and genes. We identify such co-modules using mouse and human microarray expression data. They are functionally coherent both in terms of genes and of organs from both organisms. We show that a large proportion of genes belonging to the same co-module are orthologous between mouse and human. Moreover, their zebrafish orthologs also tend to be expressed in the corresponding homologous organs. Notable exceptions to the general pattern of conservation are the testis and the olfactory bulb. Interestingly, some co-modules consist of single organs, while others combine several functionally related organs. For instance, amygdala, cerebral cortex, hypothalamus and spinal cord form a clearly discernible unit of expression, both in mouse and human. Our study provides a new framework for comparative analysis which will be applicable also to other sets of large-scale phenotypic data collected across different species.

  4. Single neuron firing properties impact correlation-based population coding

    PubMed Central

    Hong, Sungho; Ratté, Stéphanie; Prescott, Steven A.; De Schutter, Erik

    2012-01-01

    Correlated spiking has been widely observed but its impact on neural coding remains controversial. Correlation arising from co-modulation of rates across neurons has been shown to vary with the firing rates of individual neurons. This translates into rate and correlation being equivalently tuned to the stimulus; under those conditions, correlated spiking does not provide information beyond that already available from individual neuron firing rates. Such correlations are irrelevant and can reduce coding efficiency by introducing redundancy. Using simulations and experiments in rat hippocampal neurons, we show here that pairs of neurons receiving correlated input also exhibit correlations arising from precise spike-time synchronization. Contrary to rate co-modulation, spike-time synchronization is unaffected by firing rate, thus enabling synchrony- and rate-based coding to operate independently. The type of output correlation depends on whether intrinsic neuron properties promote integration or coincidence detection: “ideal” integrators (with spike generation sensitive to stimulus mean) exhibit rate co-modulation whereas “ideal” coincidence detectors (with spike generation sensitive to stimulus variance) exhibit precise spike-time synchronization. Pyramidal neurons are sensitive to both stimulus mean and variance, and thus exhibit both types of output correlation proportioned according to which operating mode is dominant. Our results explain how different types of correlations arise based on how individual neurons generate spikes, and why spike-time synchronization and rate co-modulation can encode different stimulus properties. Our results also highlight the importance of neuronal properties for population-level coding insofar as neural networks can employ different coding schemes depending on the dominant operating mode of their constituent neurons. PMID:22279226

  5. Masking Release in Children and Adults with Hearing Loss When Using Amplification

    ERIC Educational Resources Information Center

    Brennan, Marc; McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose: This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method: Sentence recognition in unmodulated noise was compared with recognition…

  6. Listeners Experience Linguistic Masking Release in Noise-Vocoded Speech-in-Speech Recognition

    ERIC Educational Resources Information Center

    Viswanathan, Navin; Kokkinakis, Kostas; Williams, Brittany T.

    2018-01-01

    Purpose: The purpose of this study was to evaluate whether listeners with normal hearing perceiving noise-vocoded speech-in-speech demonstrate better intelligibility of target speech when the background speech was mismatched in language (linguistic release from masking [LRM]) and/or location (spatial release from masking [SRM]) relative to the…

  7. Contribution of Binaural Masking Release to Improved Speech Intelligibility for different Masker types.

    PubMed

    Sutojo, Sarinah; van de Par, Steven; Schoenmaker, Esther

    2018-06-01

    In situations with competing talkers or in the presence of masking noise, speech intelligibility can be improved by spatially separating the target speaker from the interferers. This advantage is generally referred to as spatial release from masking (SRM) and different mechanisms have been suggested to explain it. One proposed mechanism to benefit from spatial cues is the binaural masking release, which is purely stimulus driven. According to this mechanism, the spatial benefit results from differences in the binaural cues of target and masker, which need to appear simultaneously in time and frequency to improve the signal detection. In an alternative proposed mechanism, the differences in the interaural cues improve the segregation of auditory streams, a process, which involves top-down processing rather than being purely stimulus driven. Other than the cues that produce binaural masking release, the interaural cue differences between target and interferer required to improve stream segregation do not have to appear simultaneously in time and frequency. This study is concerned with the contribution of binaural masking release to SRM for three masker types that differ with respect to the amount of energetic masking they exert. Speech intelligibility was measured, employing a stimulus manipulation that inhibits binaural masking release, and analyzed with a metric to account for the number of better-ear glimpses. Results indicate that the contribution of the stimulus-driven binaural masking release plays a minor role while binaural stream segregation and the availability of glimpses in the better ear had a stronger influence on improving the speech intelligibility. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Determining the energetic and informational components of speech-on-speech masking

    PubMed Central

    Kidd, Gerald; Mason, Christine R.; Swaminathan, Jayaganesh; Roverud, Elin; Clayton, Kameron K.; Best, Virginia

    2016-01-01

    Identification of target speech was studied under masked conditions consisting of two or four independent speech maskers. In the reference conditions, the maskers were colocated with the target, the masker talkers were the same sex as the target, and the masker speech was intelligible. The comparison conditions, intended to provide release from masking, included different-sex target and masker talkers, time-reversal of the masker speech, and spatial separation of the maskers from the target. Significant release from masking was found for all comparison conditions. To determine whether these reductions in masking could be attributed to differences in energetic masking, ideal time-frequency segregation (ITFS) processing was applied so that the time-frequency units where the masker energy dominated the target energy were removed. The remaining target-dominated “glimpses” were reassembled as the stimulus. Speech reception thresholds measured using these resynthesized ITFS-processed stimuli were the same for the reference and comparison conditions supporting the conclusion that the amount of energetic masking across conditions was the same. These results indicated that the large release from masking found under all comparison conditions was due primarily to a reduction in informational masking. Furthermore, the large individual differences observed generally were correlated across the three masking release conditions. PMID:27475139

  9. Categorical scaling of partial loudness in a condition of masking release.

    PubMed

    Verhey, Jesko L; Heeren, Wiebke

    2015-08-01

    Categorical loudness scaling was used to measure suprathreshold release from masking. The signal was a 986-Hz sinusoid that was embedded in a bandpass-filtered masking noise. This noise was either unmodulated or was amplitude modulated with a square-wave modulator. The unmodulated noise had either the same level as the modulated noise or had a level that was reduced by the difference in thresholds for the 986-Hz signal obtained with the modulated and unmodulated noise masker presented at the same level (i.e., the masking release). A comparison with loudness matching data of the same set of subjects showed that the data obtained with loudness scaling capture main aspects of the change in suprathreshold perception of the sinusoid when the masker was modulated. The scaling data for the signal masked by the unmodulated noise with the reduced masker level were similar to that for the signal embedded in the modulated noise. This similarity supports the hypothesis that the mechanism eliciting the masking release is effectively reducing the masker level.

  10. Spatial Release From Masking in Simulated Cochlear Implant Users With and Without Access to Low-Frequency Acoustic Hearing

    PubMed Central

    Dietz, Mathias; Hohmann, Volker; Jürgens, Tim

    2015-01-01

    For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch). Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types. PMID:26721918

  11. Captive breeding and reintroduction of the endangered masked bobwhite

    USGS Publications Warehouse

    Carpenter, J.W.; Gabel, R.R.; Goodwin, J.G.

    1991-01-01

    Efforts to restore the endangered masked bobwhite (Colinus virginianus ridgwayi) to its former range have required 1) habitat acquisition, restoration, and preservation; 2) captive propagation; and 3) reintroduction .bf captive-bred stock. In its role to recover the masked bobwhite, the Patuxent Wildlife Research Center (U.S. Fish and Wildli e Service) has refined captive breeding techniques; provided captive-produced stock for release; conducted field research on the distribution, limiting factors, and habitat characteristics of this species; and developed release methods. Techniques for the husbandry and captive management, breeding, artificial incubation and hatching of eggs, and rearing of young of the masked bobwhite have been developed. Successful reintroduction techniques for the masked bobwhite have included prerelease conditioning and/or cross-fostering of captive-reared masked bobwhite chicks to a wild-caught, related, vasectomized bobwhite species and their release to the wild as family units. In addition, the establishment by the U. S. Fish and Wildlife Service of the Buenos Aires National Wildlife Refuge in 1985 has further enhanced the potential for establishing a self-sustaining population of the masked bobwhite in the U. S. Through continued releases and active management of habitat, therefore, it is believed that the masked bobwhite can become permanently established at the refuge to ensure its continued survival in the wild.

  12. The interaction of acoustic and linguistic grouping cues in auditory object formation

    NASA Astrophysics Data System (ADS)

    Shapley, Kathy; Carrell, Thomas

    2005-09-01

    One of the earliest explanations for good speech intelligibility in poor listening situations was context [Miller et al., J. Exp. Psychol. 41 (1951)]. Context presumably allows listeners to group and predict speech appropriately and is known as a top-down listening strategy. Amplitude comodulation is another mechanism that has been shown to improve sentence intelligibility. Amplitude comodulation provides acoustic grouping information without changing the linguistic content of the desired signal [Carrell and Opie, Percept. Psychophys. 52 (1992); Hu and Wang, Proceedings of ICASSP-02 (2002)] and is considered a bottom-up process. The present experiment investigated how amplitude comodulation and semantic information combined to improve speech intelligibility. Sentences with high- and low-predictability word sequences [Boothroyd and Nittrouer, J. Acoust. Soc. Am. 84 (1988)] were constructed in two different formats: time-varying sinusoidal sentences (TVS) and reduced-channel sentences (RC). The stimuli were chosen because they minimally represent the traditionally defined speech cues and therefore emphasized the importance of the high-level context effects and low-level acoustic grouping cues. Results indicated that semantic information did not influence intelligibility levels of TVS and RC sentences. In addition amplitude modulation aided listeners' intelligibility scores in the TVS condition but hindered listeners' intelligibility scores in the RC condition.

  13. Spatial Release from Masking in Children: Effects of Simulated Unilateral Hearing Loss

    PubMed Central

    Corbin, Nicole E.; Buss, Emily; Leibold, Lori J.

    2016-01-01

    Objectives The purpose of this study was twofold: 1) to determine the effect of an acute simulated unilateral hearing loss on children’s spatial release from masking in two-talker speech and speech-shaped noise, and 2) to develop a procedure to be used in future studies that will assess spatial release from masking in children who have permanent unilateral hearing loss. There were three main predictions. First, spatial release from masking was expected to be larger in two-talker speech than speech-shaped noise. Second, simulated unilateral hearing loss was expected to worsen performance in all listening conditions, but particularly in the spatially separated two-talker speech masker. Third, spatial release from masking was expected to be smaller for children than for adults in the two-talker masker. Design Participants were 12 children (8.7 to 10.9 yrs) and 11 adults (18.5 to 30.4 yrs) with normal bilateral hearing. Thresholds for 50%-correct recognition of Bamford-Kowal-Bench sentences were measured adaptively in continuous two-talker speech or speech-shaped noise. Target sentences were always presented from a loudspeaker at 0° azimuth. The masker stimulus was either co-located with the target or spatially separated to +90° or −90° azimuth. Spatial release from masking was quantified as the difference between thresholds obtained when the target and masker were co-located and thresholds obtained when the masker was presented from +90° or − 90°. Testing was completed both with and without a moderate simulated unilateral hearing loss, created with a foam earplug and supra-aural earmuff. A repeated-measures design was used to compare performance between children and adults, and performance in the no-plug and simulated-unilateral-hearing-loss conditions. Results All listeners benefited from spatial separation of target and masker stimuli on the azimuth plane in the no-plug listening conditions; this benefit was larger in two-talker speech than in speech-shaped noise. In the simulated-unilateral-hearing-loss conditions, a positive spatial release from masking was observed only when the masker was presented ipsilateral to the simulated unilateral hearing loss. In the speech-shaped noise masker, spatial release from masking in the no-plug condition was similar to that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. In contrast, in the two-talker speech masker, spatial release from masking in the no-plug condition was much larger than that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. When either masker was presented contralateral to the simulated unilateral hearing loss, spatial release from masking was negative. This pattern of results was observed for both children and adults, although children performed more poorly overall. Conclusions Children and adults with normal bilateral hearing experience greater spatial release from masking for a two-talker speech than a speech-shaped noise masker. Testing in a two-talker speech masker revealed listening difficulties in the presence of disrupted binaural input that were not observed in a speech-shaped noise masker. This procedure offers promise for the assessment of spatial release from masking in children with permanent unilateral hearing loss. PMID:27787392

  14. Relative Yetter-Drinfeld modules and comodules over braided groups

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Haixing, E-mail: zhuhaixing@163.com, E-mail: haxing.zhu@njfu.edu.cn

    Let H{sub 1} be a quantum group and f : H{sub 1}⟶H{sub 2} a Hopf algebra homomorphism. Assume that B is some braided group obtained by Majid’s transmutation process. We first show that there is a tensor equivalence between the category of comodules over the braided group B and that of relative Yetter-Drinfeld modules. Next, we prove that the Drinfeld centers of the two categories mentioned above are equivalent to the category of modules over some quantum double, namely, the category of ordinary Yetter-Drinfeld modules over some Radford’s biproduct Hopf algebra. Importantly, the above results not only hold for amore » finite dimensional quantum group but also for an infinite dimensional one.« less

  15. Microstructural investigation using synchrotron radiation X-ray microtomography reveals taste-masking mechanism of acetaminophen microspheres.

    PubMed

    Guo, Zhen; Yin, Xianzhen; Liu, Congbiao; Wu, Li; Zhu, Weifeng; Shao, Qun; York, Peter; Patterson, Laurence; Zhang, Jiwen

    2016-02-29

    The structure of solid drug delivery systems has considerable influence on drug release behaviors from particles and granules and also impacts other properties relevant to release characteristics such as taste. In this study, lipid-based microspheres of acetaminophen were prepared to mask the undesirable taste of drug and therefore to identify the optimal formulation for drug release. Synchrotron radiation X-ray computed microtomography (SR-μCT) was used to investigate the fine structural architectures of microspheres non-destructively at different sampling times during drug release test, which were simultaneously determined to quantitatively correlate the structural data with drug release behaviors. The results demonstrated that the polymeric formulation component, namely, cationic polymethacrylate (Eudragit E100), was the key factor to mask the bitter taste of acetaminophen by inhibiting immediate drug release thereby reducing the interaction intensity of the bitter material with the oral cavity taste buds. The structure and morphology of the microspheres were found to be influenced by the shape and particle size of the drug, which was also an important factor for taste-masking performance. The quantitative analysis generated detailed structural information which was correlated well with drug release behaviors. Thus, SR-μCT has been proved as a powerful tool to investigate the fine microstructure of particles and provides a new approach in the design of particles for taste masking. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Monaural informational masking release in children and adults

    NASA Astrophysics Data System (ADS)

    Buss, Emily; Hall, Joseph W.; Grose, John H.

    2004-05-01

    Informational masking refers to an elevation in signal threshold due to stimulus uncertainty, rather than to energetic masking. This study assessed informational masking and utilization of cues to reduce that masking in children aged 5-9 and adults. We used a manipulation introduced by Kidd et al. [J. Acoust. Soc. Am. 95, 3475-3480 (1994)] in which the signal was a train of eight consecutive tone bursts, each at 1 kHz and 60 ms in duration. Maskers were comprised of a pair of synchronous tone-burst trains whose frequencies were selected from the range spanning 0.2-5 kHz, with a protected region 851-1175 Hz. In the reference condition, where informational masking is pronounced, these maskers were eight bursts and had a fixed frequency within each interval, with new frequencies chosen randomly prior to each interval. Two conditions of masking release were tested: random frequency selection for each masker burst and a masker leading fringe of two additional 60-ms bursts. Both children and adults showed a significant informational masking effect, with children showing a larger effect. Both groups also showed significant release from masking, though initial results suggest that this may have been reduced in the youngest children. [Work supported by NIH, RO1 DC00397.

  17. Factors affecting speech understanding in gated interference: Cochlear implant users and normal-hearing listeners

    NASA Astrophysics Data System (ADS)

    Nelson, Peggy B.; Jin, Su-Hyun

    2004-05-01

    Previous work [Nelson, Jin, Carney, and Nelson (2003), J. Acoust. Soc. Am 113, 961-968] suggested that cochlear implant users do not benefit from masking release when listening in modulated noise. The previous findings indicated that implant users experience little to no release from masking when identifying sentences in speech-shaped noise, regardless of the modulation frequency applied to the noise. The lack of masking release occurred for all implant subjects who were using three different devices and speech processing strategies. In the present study, possible causes of this reduced masking release in implant listeners were investigated. Normal-hearing listeners, implant users, and normal-hearing listeners presented with a four-band simulation of a cochlear implant were tested for their understanding of sentences in gated noise (1-32 Hz gate frequencies) when the duty cycle of the noise was varied from 25% to 75%. No systematic effect of noise duty cycle on implant and simulation listeners' performance was noted, indicating that the masking caused by gated noise is not only energetic masking. Masking release significantly increased when the number of spectral channels was increased from 4 to 12 for simulation listeners, suggesting that spectral resolution is important for masking release. Listeners were also tested for their understanding of gated sentences (sentences in quiet interrupted by periods of silence ranging from 1 to 32 Hz as a measure of auditory fusion, or the ability to integrate speech across temporal gaps. Implant and simulation listeners had significant difficulty understanding gated sentences at every gate frequency. When the number of spectral channels was increased for simulation listeners, their ability to understand gated sentences improved significantly. Findings suggest that implant listeners' difficulty understanding speech in modulated conditions is related to at least two (possibly related) factors: degraded spectral information and limitations in auditory fusion across temporal gaps.

  18. Perception of stochastic envelopes by normal-hearing and cochlear-implant listeners

    PubMed Central

    Gomersall, Philip A.; Turner, Richard E.; Baguley, David M.; Deeks, John M.; Gockel, Hedwig E.; Carlyon, Robert P.

    2016-01-01

    We assessed auditory sensitivity to three classes of temporal-envelope statistics (modulation depth, modulation rate, and comodulation) that are important for the perception of ‘sound textures’. The textures were generated by a probabilistic model that prescribes the temporal statistics of a selected number of modulation envelopes, superimposed onto noise carriers. Discrimination thresholds were measured for normal-hearing (NH) listeners and users of a MED-EL pulsar cochlear implant (CI), for separate manipulations of the average rate and modulation depth of the envelope in each frequency band of the stimulus, and of the co-modulation between bands. Normal-hearing (NH) listeners' discrimination of envelope rate was similar for baseline modulation rates of 5 and 34 Hz, and much poorer than previously reported for sinusoidally amplitude-modulated sounds. In contrast, discrimination of model parameters that controlled modulation depth was poorer at the lower baseline rate, consistent with the idea that, at the lower rate, subjects get fewer ‘looks’ at the relevant information when comparing stimuli differing in modulation depth. NH listeners could discriminate differences in co-modulation across bands; a multidimensional scaling study revealed that this was likely due to genuine across-frequency processing, rather than within-channel cues. CI users' discrimination performance was worse overall than for NH listeners, but showed a similar dependence on stimulus parameters. PMID:26706708

  19. Evoked-potential recovery during double click stimulation in a beluga whale: implications for biosonar gain control.

    PubMed

    Supin, Alexander Ya; Popov, Vladimir V

    2015-05-01

    Auditory evoked potentials (AEPs) were recorded in a beluga whale Delphinapterus leucas using a double-pulse stimulation paradigm, specifically measuring the recovery (release from masking) of the second (test) response as a function of delay after the first (conditioning) pulse at various levels of the conditioning and test stimuli. The conditioning/test stimulus level ratio influenced the recovery time (the higher the ratio, the longer the recovery). This interrelation was used to evaluate the intensity/time trade in release from forward masking. Trade was evaluated as 32.2 dB per time decade. Data were considered as simulating interactions between the transmitted pulse and echo during echolocation, assuming that a transmitted sonar pulse produces forward masking of the echo response. With increased target distance, the attenuation of the echo may be compensated by the release from masking. According to the model, the compensation results in substantial stabilization of the echo response even if the intensity/time trade of release from masking is not precisely equal to the rate of echo attenuation with distance.

  20. The bright-star masks for the HSC-SSP survey

    NASA Astrophysics Data System (ADS)

    Coupon, Jean; Czakon, Nicole; Bosch, James; Komiyama, Yutaka; Medezinski, Elinor; Miyazaki, Satoshi; Oguri, Masamune

    2018-01-01

    We present the procedure to build and validate the bright-star masks for the Hyper-Suprime-Cam Strategic Subaru Proposal (HSC-SSP) survey. To identify and mask the saturated stars in the full HSC-SSP footprint, we rely on the Gaia and Tycho-2 star catalogues. We first assemble a pure star catalogue down to GGaia < 18 after removing ˜1.5% of sources that appear extended in the Sloan Digital Sky Survey (SDSS). We perform visual inspection on the early data from the S16A internal release of HSC-SSP, finding that our star catalogue is 99.2% pure down to GGaia < 18. Second, we build the mask regions in an automated way using stacked detected source measurements around bright stars binned per GGaia magnitude. Finally, we validate those masks by visual inspection and comparison with the literature of galaxy number counts and angular two-point correlation functions. This version (Arcturus) supersedes the previous version (Sirius) used in the S16A internal and DR1 public releases. We publicly release the full masks and tools to flag objects in the entire footprint of the planned HSC-SSP observations at "ftp://obsftp.unige.ch/pub/coupon/brightStarMasks/HSC-SSP/".

  1. Masking overshoot: Effects of ipsilateral, bilateral and contralateral priming

    NASA Astrophysics Data System (ADS)

    Connington, Maureen Catherine

    This study was concerned with masking overshoot, the elevation of the threshold of a brief signal when it is presented at the onset of a masking noise rather than at its temporal center. More specifically, it was concerned with the release from overshoot (i.e., threshold improvement) produced by priming stimuli, presented ipsilaterally, bilaterally and contralaterally at primer- masker gaps of 20, 40 and 80 msec. The more general purpose of the study was to assess the contributions of peripheral and central factors to the overshoot and overshoot-release phenomena. The primers and masking stimuli consisted of white noise bursts of 200 and 400 msec duration, respectively. The probe signal was a 20 msec 4kHz tone. The tone and masker were always presented in one ear. There were, however, 3 modes of primer presentation: ipsilateral, bilateral (identical waveforms to both ears) and contralateral. Three primer-masker gaps of 20, 40 and 80 msec were used. Five normally hearing adults were tested at primer and masker levels of 80 dB HL. Four of the five subjects exhibited significant masking overshoot, when tested without priming. Ipsilateral priming with 20 and 40 msec gaps produced significant masking release from overshoot. Threshold became poorer, however with increasing gap duration and with increasing distance of the perceived primer from the test ear (i.e. ipsilateral priming produced better thresholds than did bilateral priming and bilateral priming produced better thresholds than contralateral priming). There was significant masking enhancement (i.e. threshold was significantly poorer than in the unprimed probe at onset condition) with the contralateral 80 msec primer. The fact that ipsilateral and bilateral primers performed differently does not support the theory that masking overshoot and its release are solely the results of peripheral adaptation. In fact, the group results support the conclusion that masking overshoot is influenced by central factors. However, there were marked inter-subject differences. It seems possible that masking overshoot and its release are influenced by both peripheral adaptation effects and central processes and that the balance between the two is subject-dependent.

  2. Optimizing the taste-masked formulation of acetaminophen using sodium caseinate and lecithin by experimental design.

    PubMed

    Hoang Thi, Thanh Huong; Lemdani, Mohamed; Flament, Marie-Pierre

    2013-09-10

    In a previous study of ours, the association of sodium caseinate and lecithin was demonstrated to be promising for masking the bitterness of acetaminophen via drug encapsulation. The encapsulating mechanisms were suggested to be based on the segregation of multicomponent droplets occurring during spray-drying. The spray-dried particles delayed the drug release within the mouth during the early time upon administration and hence masked the bitterness. Indeed, taste-masking is achieved if, within the frame of 1-2 min, drug substance is either not released or the released amount is below the human threshold for identifying its bad taste. The aim of this work was (i) to evaluate the effect of various processing and formulation parameters on the taste-masking efficiency and (ii) to determine the optimal formulation for optimal taste-masking effect. Four investigated input variables included inlet temperature (X1), spray flow (X2), sodium caseinate amount (X3) and lecithin amount (X4). The percentage of drug release amount during the first 2 min was considered as the response variable (Y). A 2(4)-full factorial design was applied and allowed screening for the most influential variables i.e. sodium caseinate amount and lecithin amount. Optimizing these two variables was therefore conducted by a simplex approach. The SEM and DSC results of spray-dried powder prepared under optimal conditions showed that drug seemed to be well encapsulated. The drug release during the first 2 min significantly decreased, 7-fold less than the unmasked drug particles. Therefore, the optimal formulation that performed the best taste-masking effect was successfully achieved. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Releasing captive-reared masked bobwhite for population recovery: A review

    USGS Publications Warehouse

    Gall, S.A.; Kuvlesky, W.P.; Gee, G.; Brennan, L.A.; Palmer, W.E.; Burger, L.W.; Pruden, T.L.

    2000-01-01

    Efforts to re-establish the endangered masked bobwhite (Colinus virginianus ridgwayi) to it's former southern Arizona range have been ongoing since establishment of the Buenos Aires National Wildlife Refuge in 1986. Pre-release conditioning techniques developed prior to Refuge establishment continued to be utilized in an effort to improve post-release survival of captive-reared masked bobwhite chicks. Foremost among these techniques was the use of wild Texas bobwhite (C. v. texanus) males as foster parents which were paired with all broods released on the Refuge. The efficacy of this technique was evaluated using radio telemetry in 1994, and the results indicated that the use of foster Texas males was not as effective as had been presumed because post-release chick survival was poor. Therefore, in 1995 pre-release conditioning protocol were modified in an effort to improve post-release survival. The primary intent of these modifications was to emphasize wild behavior among chicks prior to release. Modifications to established protocol included imprinting chicks to adult bobwhites immediately after eggs hatched and exposing 1-to-2 day old chicks to natural foods (insects and seeds) while they were in brooder units. Foster parents and their respective broods were then placed in flight pens that mimicked the natural conditions that would confront broods upon release. Family groups were held in flight pens for several weeks for acclimatization purposes and then transported to temporary enclosures erected at release sites where they were held for a week and then released. Finally all releases were conducted during fall after covey formation was apparent to ensure that foster parents and released chicks remained with a group of birds. Preliminary results indicated that post-release chick survival was higher than what was observed in 1994. Pre-conditioning research will continue in an effort to further quantify post-release survival of masked bobwhite chicks. Although the results of this research project are preliminary, it is possible that pre-release conditioning techniques developed for masked bobwhites will prove useful to quail reestablishment efforts throughout North America.

  4. The characteristics of bacterial nanocellulose gel releasing silk sericin for facial treatment.

    PubMed

    Aramwit, Pornanong; Bang, Nipaporn

    2014-12-09

    Recently, naturally derived facial masks with beneficial biological properties have received increasing interest. In this study, silk sericin-releasing bacterial nanocellulose gel was developed to be applied as a bioactive mask for facial treatment. The silk sericin-releasing bacterial nanocellulose gel produced at a pH of 4.5 had an ultrafine and extremely pure fiber network structure. The mechanical properties and moisture absorption ability of the gel were improved, compared to those of the commercially available paper mask. Silk sericin could be control-released from the gel. A peel test with porcine skin showed that the gel was less adhesive than the commercially available paper mask, which would be removed from the face more easily without pain. The in vitro cytotoxicity test showed that the gel was not toxic to L929 mouse fibroblast and HaCaT human keratinocyte cells. Furthermore, when implanted subcutaneously and evaluated according to ISO10993-6 standard, the gel was not irritant to tissue. The silk sericin-releasing bacterial nanocellulose gel had appropriate physical and biological properties and safety for the facial treatment application.

  5. Selective spatial attention modulates bottom-up informational masking of speech

    PubMed Central

    Carlile, Simon; Corkhill, Caitlin

    2015-01-01

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20 dB improvement in speech reception threshold; 40% of which was attributed to a release from informational masking. When across frequency temporal modulations in the masker talkers are decorrelated the speech is unintelligible, although the within frequency modulation characteristics remains identical. Used as a masker as above, the information masking accounted for 37% of the spatial unmasking seen with this masker. This unintelligible and highly differentiable masker is unlikely to involve top-down processes. These data provides strong evidence of bottom-up masking involving speech-like, within-frequency modulations and that this, presumably low level process, can be modulated by selective spatial attention. PMID:25727100

  6. Selective spatial attention modulates bottom-up informational masking of speech.

    PubMed

    Carlile, Simon; Corkhill, Caitlin

    2015-03-02

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20 dB improvement in speech reception threshold; 40% of which was attributed to a release from informational masking. When across frequency temporal modulations in the masker talkers are decorrelated the speech is unintelligible, although the within frequency modulation characteristics remains identical. Used as a masker as above, the information masking accounted for 37% of the spatial unmasking seen with this masker. This unintelligible and highly differentiable masker is unlikely to involve top-down processes. These data provides strong evidence of bottom-up masking involving speech-like, within-frequency modulations and that this, presumably low level process, can be modulated by selective spatial attention.

  7. A Functional and Regulatory Network Associated with PIP Expression in Human Breast Cancer

    PubMed Central

    Debily, Marie-Anne; Marhomy, Sandrine El; Boulanger, Virginie; Eveno, Eric; Mariage-Samson, Régine; Camarca, Alessandra; Auffray, Charles; Piatier-Tonneau, Dominique; Imbeaud, Sandrine

    2009-01-01

    Background The PIP (prolactin-inducible protein) gene has been shown to be expressed in breast cancers, with contradictory results concerning its implication. As both the physiological role and the molecular pathways in which PIP is involved are poorly understood, we conducted combined gene expression profiling and network analysis studies on selected breast cancer cell lines presenting distinct PIP expression levels and hormonal receptor status, to explore the functional and regulatory network of PIP co-modulated genes. Principal Findings Microarray analysis allowed identification of genes co-modulated with PIP independently of modulations resulting from hormonal treatment or cell line heterogeneity. Relevant clusters of genes that can discriminate between [PIP+] and [PIP−] cells were identified. Functional and regulatory network analyses based on a knowledge database revealed a master network of PIP co-modulated genes, including many interconnecting oncogenes and tumor suppressor genes, half of which were detected as differentially expressed through high-precision measurements. The network identified appears associated with an inhibition of proliferation coupled with an increase of apoptosis and an enhancement of cell adhesion in breast cancer cell lines, and contains many genes with a STAT5 regulatory motif in their promoters. Conclusions Our global exploratory approach identified biological pathways modulated along with PIP expression, providing further support for its good prognostic value of disease-free survival in breast cancer. Moreover, our data pointed to the importance of a regulatory subnetwork associated with PIP expression in which STAT5 appears as a potential transcriptional regulator. PMID:19262752

  8. Frogs Exploit Statistical Regularities in Noisy Acoustic Scenes to Solve Cocktail-Party-like Problems.

    PubMed

    Lee, Norman; Ward, Jessica L; Vélez, Alejandro; Micheyl, Christophe; Bee, Mark A

    2017-03-06

    Noise is a ubiquitous source of errors in all forms of communication [1]. Noise-induced errors in speech communication, for example, make it difficult for humans to converse in noisy social settings, a challenge aptly named the "cocktail party problem" [2]. Many nonhuman animals also communicate acoustically in noisy social groups and thus face biologically analogous problems [3]. However, we know little about how the perceptual systems of receivers are evolutionarily adapted to avoid the costs of noise-induced errors in communication. In this study of Cope's gray treefrog (Hyla chrysoscelis; Hylidae), we investigated whether receivers exploit a potential statistical regularity present in noisy acoustic scenes to reduce errors in signal recognition and discrimination. We developed an anatomical/physiological model of the peripheral auditory system to show that temporal correlation in amplitude fluctuations across the frequency spectrum ("comodulation") [4-6] is a feature of the noise generated by large breeding choruses of sexually advertising males. In four psychophysical experiments, we investigated whether females exploit comodulation in background noise to mitigate noise-induced errors in evolutionarily critical mate-choice decisions. Subjects experienced fewer errors in recognizing conspecific calls and in selecting the calls of high-quality mates in the presence of simulated chorus noise that was comodulated. These data show unequivocally, and for the first time, that exploiting statistical regularities present in noisy acoustic scenes is an important biological strategy for solving cocktail-party-like problems in nonhuman animal communication. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A nanohybrid system for taste masking of sildenafil.

    PubMed

    Lee, Ji-Hee; Choi, Goeun; Oh, Yeon-Ji; Park, Je Won; Choy, Young Bin; Park, Mung Chul; Yoon, Yeo Joon; Lee, Hwa Jeong; Chang, Hee Chul; Choy, Jin-Ho

    2012-01-01

    A nanohybrid was prepared with an inorganic clay material, montmorillonite (MMT), for taste masking of sildenafil (SDN). To further improve the taste-masking efficiency and enhance the drug-release rate, we coated the nanohybrid of SDN-MMT with a basic polymer, polyvinylacetal diethylaminoacetate (AEA). Powder X-ray diffraction and Fourier transform infrared experiments showed that SDN was successfully intercalated into the interlayer space of MMT. The AEA-coated SDN-MMT nanohybrid showed drug release was much suppressed at neutral pH (release rate, 4.70 ± 0.53%), suggesting a potential for drug taste masking at the buccal cavity. We also performed in vitro drug release experiments in a simulated gastric fluid (pH = 1.2) and compared the drug-release profiles of AEA-coated SDN-MMT and Viagra(®), an approved dosage form of SDN. As a result, about 90% of SDN was released from the AEA-coated SDN-MMT during the first 2 hours while almost 100% of drug was released from Viagra(®). However, an in vivo experiment showed that the AEA-coated SDN-MMT exhibited higher drug exposure than Viagra(®). For the AEA-coated SDN-MMT, the area under the plasma concentration- time curve from 0 hours to infinity (AUC(0-∞)) and maximum concentration (C(max)) were 78.8 ± 2.32 μg · hour/mL and 12.4 ± 0.673 μg/mL, respectively, both of which were larger than those obtained with Viagra(®) (AUC(0-∞) = 69.2 ± 3.19 μg · hour/mL; C(max) = 10.5 ± 0.641 μg/mL). Therefore, we concluded that the MMT-based nanohybrid is a promising delivery system for taste masking of SDN with possibly improved drug exposure.

  10. A nanohybrid system for taste masking of sildenafil

    PubMed Central

    Lee, Ji-Hee; Choi, Goeun; Oh, Yeon-Ji; Park, Je Won; Choy, Young Bin; Park, Mung Chul; Yoon, Yeo Joon; Lee, Hwa Jeong; Chang, Hee Chul; Choy, Jin-Ho

    2012-01-01

    A nanohybrid was prepared with an inorganic clay material, montmorillonite (MMT), for taste masking of sildenafil (SDN). To further improve the taste-masking efficiency and enhance the drug-release rate, we coated the nanohybrid of SDN–MMT with a basic polymer, polyvinylacetal diethylaminoacetate (AEA). Powder X-ray diffraction and Fourier transform infrared experiments showed that SDN was successfully intercalated into the interlayer space of MMT. The AEA-coated SDN–MMT nanohybrid showed drug release was much suppressed at neutral pH (release rate, 4.70 ± 0.53%), suggesting a potential for drug taste masking at the buccal cavity. We also performed in vitro drug release experiments in a simulated gastric fluid (pH = 1.2) and compared the drug-release profiles of AEA-coated SDN–MMT and Viagra®, an approved dosage form of SDN. As a result, about 90% of SDN was released from the AEA-coated SDN–MMT during the first 2 hours while almost 100% of drug was released from Viagra®. However, an in vivo experiment showed that the AEA-coated SDN–MMT exhibited higher drug exposure than Viagra®. For the AEA-coated SDN–MMT, the area under the plasma concentration– time curve from 0 hours to infinity (AUC0-∞) and maximum concentration (Cmax) were 78.8 ± 2.32 μg · hour/mL and 12.4 ± 0.673 μg/mL, respectively, both of which were larger than those obtained with Viagra® (AUC0-∞ = 69.2 ± 3.19 μg · hour/mL; Cmax = 10.5 ± 0.641 μg/mL). Therefore, we concluded that the MMT-based nanohybrid is a promising delivery system for taste masking of SDN with possibly improved drug exposure. PMID:22619517

  11. Spatial release from masking based on binaural processing for up to six maskers

    PubMed Central

    Yost, William A.

    2017-01-01

    Spatial Release from Masking (SRM) was measured for identification of a female target word spoken in the presence of male masker words. Target words from a single loudspeaker located at midline were presented when two, four, or six masker words were presented either from the same source as the target or from spatially separated masker sources. All masker words were presented from loudspeakers located symmetrically around the centered target source in the front azimuth hemifield. Three masking conditions were employed: speech-in-speech masking (involving both informational and energetic masking), speech-in-noise masking (involving energetic masking), and filtered speech-in-filtered speech masking (involving informational masking). Psychophysical results were summarized as three-point psychometric functions relating proportion of correct word identification to target-to-masker ratio (in decibels) for both the co-located and spatially separated target and masker sources cases. SRM was then calculated by comparing the slopes and intercepts of these functions. SRM decreased as the number of symmetrically placed masker sources increased from two to six. This decrease was independent of the type of masking, with almost no SRM measured for six masker sources. These results suggest that when SRM is dependent primarily on binaural processing, SRM is effectively limited to fewer than six sound sources. PMID:28372135

  12. Rapid acquisition of novel interface control by small ensembles of arbitrarily selected primary motor cortex neurons

    PubMed Central

    Law, Andrew J.; Rivlis, Gil

    2014-01-01

    Pioneering studies demonstrated that novel degrees of freedom could be controlled individually by directly encoding the firing rate of single motor cortex neurons, without regard to each neuron's role in controlling movement of the native limb. In contrast, recent brain-computer interface work has emphasized decoding outputs from large ensembles that include substantially more neurons than the number of degrees of freedom being controlled. To bridge the gap between direct encoding by single neurons and decoding output from large ensembles, we studied monkeys controlling one degree of freedom by comodulating up to four arbitrarily selected motor cortex neurons. Performance typically exceeded random quite early in single sessions and then continued to improve to different degrees in different sessions. We therefore examined factors that might affect performance. Performance improved with larger ensembles. In contrast, other factors that might have reflected preexisting synaptic architecture—such as the similarity of preferred directions—had little if any effect on performance. Patterns of comodulation among ensemble neurons became more consistent across trials as performance improved over single sessions. Compared with the ensemble neurons, other simultaneously recorded neurons showed less modulation. Patterns of voluntarily comodulated firing among small numbers of arbitrarily selected primary motor cortex (M1) neurons thus can be found and improved rapidly, with little constraint based on the normal relationships of the individual neurons to native limb movement. This rapid flexibility in relationships among M1 neurons may in part underlie our ability to learn new movements and improve motor skill. PMID:24920030

  13. Development of Spatial Release from Masking in Mandarin-Speaking Children with Normal Hearing

    ERIC Educational Resources Information Center

    Yuen, Kevin C. P.; Yuan, Meng

    2014-01-01

    Purpose: This study investigated the development of spatial release from masking in children using closed-set Mandarin disyllabic words and monosyllabic words carrying lexical tones as test stimuli and speech spectrum-weighted noise as a masker. Method: Twenty-six children ages 4-9 years and 12 adults, all with normal hearing, participated in…

  14. Mechanical microencapsulation: The best technique in taste masking for the manufacturing scale - Effect of polymer encapsulation on drug targeting.

    PubMed

    Al-Kasmi, Basheer; Alsirawan, Mhd Bashir; Bashimam, Mais; El-Zein, Hind

    2017-08-28

    Drug taste masking is a crucial process for the preparation of pediatric and geriatric formulations as well as fast dissolving tablets. Taste masking techniques aim to prevent drug release in saliva and at the same time to obtain the desired release profile in gastrointestinal tract. Several taste masking methods are reported, however this review has focused on a group of promising methods; complexation, encapsulation, and hot melting. The effects of each method on the physicochemical properties of the drug are described in details. Furthermore, a scoring system was established to evaluate each process using recent published data of selected factors. These include, input, process, and output factors that are related to each taste masking method. Input factors include the attributes of the materials used for taste masking. Process factors include equipment type and process parameters. Finally, output factors, include taste masking quality and yield. As a result, Mechanical microencapsulation obtained the highest score (5/8) along with complexation with cyclodextrin suggesting that these methods are the most preferable for drug taste masking. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data.

    PubMed

    Zandbergen, Paul A

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks.

  16. Spatial Release from Masking in Adults with Bilateral Cochlear Implants: Effects of Distracter Azimuth and Microphone Location

    ERIC Educational Resources Information Center

    Davis, Timothy J.; Gifford, René H.

    2018-01-01

    Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…

  17. Low surface energy polymeric release coating for improved contact print lithography

    NASA Astrophysics Data System (ADS)

    Mancini, David P.; Resnick, Douglas J.; Gehoski, Kathleen A.; Popovich, Laura L.; Chang, Daniel

    2002-03-01

    Contact printing has been used for decades in many various lithography applications in the microelectronic industry. While vacuum contact printing processes offer sub-micron resolution and high throughput, they often suffer from some important drawbacks. One of the most common problems is degradation in both resolution and defect density which occurs when the same mask si used for multiple exposures without frequent mask cleans. This is largely due to the relatively high surface energy of both quartz and chrome and the tendency of most photoresists to adhere to these surfaces. As a result, when a mask and wafer are pressed into intimate contact, resist will tend to stick to the mask creating a defect on the wafer, effectively propagating defects to subsequent wafers. In this study, DuPont Teflon AF 1601S is used as a photomask coating and evaluated for its ability to act as a release agent and reduce defects while maintaining resolution for multiple exposures. Teflon AF is an amorphous, transparent, low surface energy, polymeric material that can be spin coated into a thin conformal film. Tests have shown that when using an uncoated mask in vacuum contact, resolution of 0.75 micrometers dense lines is severely degraded after less than 10 consecutive exposures. However, when the mask is coated, 0.75 micrometers dense lines were successfully resolved using vacuum contact for over 200 exposures without cleaning. In addition, it has been demonstrated that Teflon AF coatings impart to a mask a self-cleaning capability, since particles tend to stick to the photoresist rather than the mask. A coated mask, which was purposefully contaminated with particulates, resolved 0.75 micrometers dense lines on all but the first wafer of a series of 25 consecutive exposures. The patented mask releases layer process has successfully been demonstrated with a positive novolak resist. Additional data which describes the system chemistry, dilution and coating process, and film morphology are also presented.

  18. Profiles of Patients Demonstrating Abnormal Masking Level Difference Response.

    ERIC Educational Resources Information Center

    Battin, R. Ray; Waryas, Paul A.

    1985-01-01

    Profiles of three persons (9-11 years old) with extremely reduced masking level difference results (scores which measure binaural release from masking) are reported. It is suggested that tests of the MLD appear to be a useful adjunct of an evaluation battery for patients with presumed auditory perceptual problems. (CL)

  19. Enhancement in Informational Masking

    ERIC Educational Resources Information Center

    Cao, Xiang; Richards, Virginia M.

    2012-01-01

    Purpose: The ability to detect a tone added to a random masker improves when a preview of the masker is provided. In 2 experiments, the authors explored the role that perceptual organization plays in this release from masking. Method: Detection thresholds were measured in informational masking studies. The maskers were drawn at random prior to…

  20. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data

    PubMed Central

    Zandbergen, Paul A.

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks. PMID:26556417

  1. Masking release for words in amplitude-modulated noise as a function of modulation rate and task

    PubMed Central

    Buss, Emily; Whittle, Lisa N.; Grose, John H.; Hall, Joseph W.

    2009-01-01

    For normal-hearing listeners, masked speech recognition can improve with the introduction of masker amplitude modulation. The present experiments tested the hypothesis that this masking release is due in part to an interaction between the temporal distribution of cues necessary to perform the task and the probability of those cues temporally coinciding with masker modulation minima. Stimuli were monosyllabic words masked by speech-shaped noise, and masker modulation was introduced via multiplication with a raised sinusoid of 2.5–40 Hz. Tasks included detection, three-alternative forced-choice identification, and open-set identification. Overall, there was more masking release associated with the closed than the open-set tasks. The best rate of modulation also differed as a function of task; whereas low modulation rates were associated with best performance for the detection and three-alternative identification tasks, performance improved with modulation rate in the open-set task. This task-by-rate interaction was also observed when amplitude-modulated speech was presented in a steady masker, and for low- and high-pass filtered speech presented in modulated noise. These results were interpreted as showing that the optimal rate of amplitude modulation depends on the temporal distribution of speech cues and the information required to perform a particular task. PMID:19603883

  2. Short-term visual deprivation can enhance spatial release from masking.

    PubMed

    Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François

    2016-08-15

    This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Rescuing Stimuli from Invisibility: Inducing a Momentary Release from Visual Masking with Pre-Target Entrainment

    ERIC Educational Resources Information Center

    Mathewson, Kyle E.; Fabiani, Monica; Gratton, Gabriele; Beck, Diane M.; Lleras, Alejandro

    2010-01-01

    At near-threshold levels of stimulation, identical stimulus parameters can result in very different phenomenal experiences. Can we manipulate which stimuli reach consciousness? Here we show that consciousness of otherwise masked stimuli can be experimentally induced by sensory entrainment. We preceded a backward-masked stimulus with a series of…

  4. Cross-Language Differences in Informational Masking of Speech by Speech: English versus Mandarin Chinese

    ERIC Educational Resources Information Center

    Wu, Xihong; Yang, Zhigang; Huang, Ying; Chen, Jing; Li, Liang; Daneman, Meredyth; Schneider, Bruce A.

    2011-01-01

    Purpose: The purpose of the study was to determine why perceived spatial separation provides a greater release from informational masking in Chinese than English when target sentences in each of the languages are masked by other talkers speaking the same language. Method: Monolingual speakers of English and Mandarin Chinese listened to…

  5. Effects of non-simultaneous masking on the binaural masking level difference

    PubMed Central

    Buss, Emily; Hall III, Joseph W.

    2011-01-01

    The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100–2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers’ ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking. PMID:21361448

  6. Taste masking of ondansetron hydrochloride by polymer carrier system and formulation of rapid-disintegrating tablets.

    PubMed

    Khan, Shagufta; Kataria, Prashant; Nakhat, Premchand; Yeole, Pramod

    2007-06-22

    The purpose of this research was to mask the intensely bitter taste of ondansetron HCl and to formulate a rapid-disintegrating tablet (RDT) of the taste-masked drug. Taste masking was done by complexing ondansetron HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratios by the precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.2, and molecular property. Complex that did not release drug in SSF was considered taste-masked and selected for formulation RDTs. The complex with drug-polymer ratio of 8:2 did not show drug release in SSF; therefore, it was selected. The properties of tablets such as tensile strength, wetting time, water absorption ratio, in vitro disintegration time, and disintegration in the oral cavity were investigated to elucidate the wetting and disintegration characteristics of tablets. Polyplasdone XL-10 7% wt/wt gave the minimum disintegration time. Tablets of batch F4 containing spray-dried mannitol and microcrystalline cellulose in the ratio 1:1 and 7% wt/wt Polyplasdone XL-10 showed faster disintegration, within 12.5 seconds, than the marketed tablet (112 seconds). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Taste evaluation of RDT in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) ultimately reaching to 0 within 15 minutes, whereas ondansetron HCl was rated intensely bitter with a score of 3 for 10 minutes. Tablets of batch F4 also revealed rapid drug release (t(90), 60 seconds) in SGF compared with marketed formulation (t(90), 240 seconds; P < .01). Thus, results conclusively demonstrated successful masking of taste and rapid disintegration of the formulated tablets in the oral cavity.

  7. Solid lipid microparticles containing loratadine prepared using a Micromixer.

    PubMed

    Milak, Spomenka; Medlicott, Natalie; Tucker, Ian G

    2006-12-01

    Solid lipid microparticles were investigated as a taste-masking approach for a lipophilic weak base in a suspension. The idea was that the drug concentration in the aqueous phase of a suspension might be reduced by its partitioning into the solid lipid particles. Loratadine, as a model drug, was used to prepare Precirol ATO 5 microparticles by a Micromixer. The effects of three process variables: drug loading, PVA concentration and water/lipid ratio on the microparticle size, encapsulation efficiency, surface appearance, in-vitro release and drug partitioning in a suspension were studied. Loratadine release was slow in simulated saliva and very fast at the pH of stomach. In suspension of loratadine lipid microparticles, drug was released into the aqueous phase to the same concentration as in a drug suspension. Therefore, the usefulness of these microparticles for taste-masking in liquids is limited. However, they might be useful for taste-masking in solid dosage forms.

  8. V2.2 L2AS Detailed Release Description April 15, 2002

    Atmospheric Science Data Center

    2013-03-14

    ... 'optically thick atmosphere' algorithm. Implement new experimental aerosol retrieval algorithm over homogeneous surface types. ... Change values: cloud_mask_decision_matrix(1,1): .true. -> .false. cloud_mask_decision_matrix(2,1): .true. -> .false. ...

  9. Single-Run Single-Mask Inductively-Coupled-Plasma Reactive-Ion-Etching Process for Fabricating Suspended High-Aspect-Ratio Microstructures

    NASA Astrophysics Data System (ADS)

    Yang, Yao-Joe; Kuo, Wen-Cheng; Fan, Kuang-Chao

    2006-01-01

    In this work, we present a single-run single-mask (SRM) process for fabricating suspended high-aspect-ratio structures on standard silicon wafers using an inductively coupled plasma-reactive ion etching (ICP-RIE) etcher. This process eliminates extra fabrication steps which are required for structure release after trench etching. Released microstructures with 120 μm thickness are obtained by this process. The corresponding maximum aspect ratio of the trench is 28. The SRM process is an extended version of the standard process proposed by BOSCH GmbH (BOSCH process). The first step of the SRM process is a standard BOSCH process for trench etching, then a polymer layer is deposited on trench sidewalls as a protective layer for the subsequent structure-releasing step. The structure is released by dry isotropic etching after the polymer layer on the trench floor is removed. All the steps can be integrated into a single-run ICP process. Also, only one mask is required. Therefore, the process complexity and fabrication cost can be effectively reduced. Discussions on each SRM step and considerations for avoiding undesired etching of the silicon structures during the release process are also presented.

  10. Innovative Masking of Ferrous Inserts in Magnesium Aerospace Components Prior to Tagnite Anodization (v.1, Unlimited Release)

    DTIC Science & Technology

    2013-07-01

    cadmium plating, and other metals cannot be anodized. If any of these dissimilar metals are in contact with the Tagnite electrolyte during the...commercial masking vendor had to offer. TAG contacted Acme Masking Company, Avon, Indiana , who specializes in developing masking for aluminum...were received from TAG. For the purpose of this discussion, the edge of the panel near a hole is considered a top. Each panel had a cadmium -plated

  11. Spatial release from masking improves sound pattern discrimination along a biologically relevant pulse-rate continuum in gray treefrogs

    PubMed Central

    Ward, Jessica L.; Buerkle, Nathan P.; Bee, Mark A.

    2013-01-01

    Frogs form large choruses during the mating season in which males produce loud advertisement calls to attract females and repel rival males. High background noise levels in these social aggregations can impair vocal perception. In humans, spatial release from masking contributes to our ability to understand speech in noisy social groups. Here, we tested the hypothesis that spatial separation between target signals and ‘chorus-shaped noise’ improves the ability of female gray treefrogs (Hyla chrysoscelis) to perform a behavioral discrimination task based on perceiving differences in the pulsatile structure of advertisement calls. We used two-stimulus choice tests to measure phonotaxis (approach toward sound) in response to calls differing in pulse rate along a biologically relevant continuum between conspecific (50 pulses s−1) and heterospecific (20 pulses s−1) calls. Signals were presented in quiet, in colocated noise, and in spatially separated noise. In quiet conditions, females exhibited robust preferences for calls with relatively faster pulse rates more typical of conspecific calls. Behavioral discrimination between calls differing in pulse rate was impaired in the presence of colocated noise but similar between quiet and spatially separated noise conditions. Our results indicate that spatial release from energetic masking facilitates a biologically important temporal discrimination task in frogs. We discuss these results in light of previous work on spatial release from masking in frogs and other animals. PMID:24055623

  12. Use of calcium caseinate in association with lecithin for masking the bitterness of acetaminophen--comparative study with sodium caseinate.

    PubMed

    Hoang Thi, Thanh Huong; Lemdani, Mohamed; Flament, Marie-Pierre

    2013-11-18

    Owing to a variety of structural and functional properties, milk proteins are steadily studied for food and pharmaceutical applications. In the present study, calcium caseinate in association with lecithin was firstly investigated in order to encapsulate the acetaminophen through spray-drying for taste-masking purpose for pediatric medicines. A 2(4)-full factorial design revealed that the spray flow, the calcium caseinate amount and the lecithin amount had significant effects on the release of drug during the first 2 min. Indeed, increasing the spray flow and/or the calcium caseinate amount led to increase the released amount, whereas increasing the lecithin amount decreased the released amount. The "interaction" between the calcium caseinate amount and the lecithin amount was also shown to be statistically significant. The second objective was to compare the efficiency of two caseinate-based formulations, i.e. sodium caseinate and calcium caseinate, on the taste-masking effect. The characteristics of spray-dried powders determined by SEM and DSC were shown to depend on the caseinate/lecithin proportion rather than the type of caseinate. Interestingly, calcium caseinate-based formulations were found to lower the released amount of drug during the early time to a higher extent than sodium caseinate-based formulations, which indicates better taste-masking efficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Development and Evaluation of Taste Masked Granular Formulation of Satranidazole by Melt Granulation Technique

    PubMed Central

    Pawar, Harshal Ashok; Joshi, Pooja Rasiklal

    2014-01-01

    Drugs from nitroimidazole category are generally bitter in taste. Oral formulation with bitter taste is not palatable. Geriatrics and pediatrics patients usually suffer from swallowing difficulties. Many other patients in some disease conditions avoid swallowing tablets. Satranidazole is a new nitro-imidazole derivative with bitter taste and is available in market as film coated tablet. The purpose of this research was to mask the bitter taste of Satranidazole by coating complexation with low melting point wax and Eudragit EPO. Different types of wax (glyceryl monostearate, stearic acid and cetyl alcohol) were tried for taste masking. The drug to stearic acid ratio 1 : 2 was found to be optimum on the basis of taste evaluation and in vitro release. The formulated granules were found to possess good flow property. FTIR studies confirmed that there was no interaction between drug and excipients. Scanning Electron Microscopy of drug and the optimized batch of granules was performed. The in vitro release of drug from granules was compared with marketed tablet formulation. The taste masked granules of optimized batch showed 87.65% release of drug in 1 hr which is comparable to that of marketed tablet formulation. PMID:26556200

  14. Dynamic Excitatory and Inhibitory Gain Modulation Can Produce Flexible, Robust and Optimal Decision-making

    PubMed Central

    Niyogi, Ritwik K.; Wong-Lin, KongFatt

    2013-01-01

    Behavioural and neurophysiological studies in primates have increasingly shown the involvement of urgency signals during the temporal integration of sensory evidence in perceptual decision-making. Neuronal correlates of such signals have been found in the parietal cortex, and in separate studies, demonstrated attention-induced gain modulation of both excitatory and inhibitory neurons. Although previous computational models of decision-making have incorporated gain modulation, their abstract forms do not permit an understanding of the contribution of inhibitory gain modulation. Thus, the effects of co-modulating both excitatory and inhibitory neuronal gains on decision-making dynamics and behavioural performance remain unclear. In this work, we incorporate time-dependent co-modulation of the gains of both excitatory and inhibitory neurons into our previous biologically based decision circuit model. We base our computational study in the context of two classic motion-discrimination tasks performed in animals. Our model shows that by simultaneously increasing the gains of both excitatory and inhibitory neurons, a variety of the observed dynamic neuronal firing activities can be replicated. In particular, the model can exhibit winner-take-all decision-making behaviour with higher firing rates and within a significantly more robust model parameter range. It also exhibits short-tailed reaction time distributions even when operating near a dynamical bifurcation point. The model further shows that neuronal gain modulation can compensate for weaker recurrent excitation in a decision neural circuit, and support decision formation and storage. Higher neuronal gain is also suggested in the more cognitively demanding reaction time than in the fixed delay version of the task. Using the exact temporal delays from the animal experiments, fast recruitment of gain co-modulation is shown to maximize reward rate, with a timescale that is surprisingly near the experimentally fitted value. Our work provides insights into the simultaneous and rapid modulation of excitatory and inhibitory neuronal gains, which enables flexible, robust, and optimal decision-making. PMID:23825935

  15. Schizophrenia affects speech-induced functional connectivity of the superior temporal gyrus under cocktail-party listening conditions.

    PubMed

    Li, Juanhua; Wu, Chao; Zheng, Yingjun; Li, Ruikeng; Li, Xuanzi; She, Shenglin; Wu, Haibo; Peng, Hongjun; Ning, Yuping; Li, Liang

    2017-09-17

    The superior temporal gyrus (STG) is involved in speech recognition against informational masking under cocktail-party-listening conditions. Compared to healthy listeners, people with schizophrenia perform worse in speech recognition under informational speech-on-speech masking conditions. It is not clear whether the schizophrenia-related vulnerability to informational masking is associated with certain changes in FC of the STG with some critical brain regions. Using sparse-sampling fMRI design, this study investigated the differences between people with schizophrenia and healthy controls in FC of the STG for target-speech listening against informational speech-on-speech masking, when a listening condition with either perceived spatial separation (PSS, with a spatial release of informational masking) or perceived spatial co-location (PSC, without the spatial release) between target speech and masking speech was introduced. The results showed that in healthy participants, but not participants with schizophrenia, the contrast of either the PSS or PSC condition against the masker-only condition induced an enhancement of functional connectivity (FC) of the STG with the left superior parietal lobule and the right precuneus. Compared to healthy participants, participants with schizophrenia showed declined FC of the STG with the bilateral precuneus, right SPL, and right supplementary motor area. Thus, FC of the STG with the parietal areas is normally involved in speech listening against informational masking under either the PSS or PSC conditions, and declined FC of the STG in people with schizophrenia with the parietal areas may be associated with the increased vulnerability to informational masking. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  16. Development of taste masked caffeine citrate formulations utilizing hot melt extrusion technology and in vitro-in vivo evaluations

    PubMed Central

    Pimparade, Manjeet. B.; Morott, Joseph T.; Park, Jun-Bom; Kulkarni, Vijay I.; Majumdar, Soumyajit; Murthy, S. N.; Lian, Zhuoyang; Pinto, Elanor; Bi, Vivian; Durig, Thomas; Murthy, Reena; Shivakumar, H.N; Vanaja, K.; Kumar, C. P; Repka, Michael A.

    2015-01-01

    The objective of this study was to develop caffeine citrate orally disintegrating tablet (ODT) formulations utilizing hot-melt extrusion technology and evaluate the ability of the formulation composition to mask the unpleasant bitter taste of the drug using in vitro and in vivo methods. Ethylcellulose, along with a suitable plasticizer, was used as a polymeric carrier. Pore forming agents were incorporated into the extruded matrix to enhance drug release. A modified screw configuration was applied to improve the extrusion processability and to preserve the crystallinity of the API. The milled extrudates were subjected to dissolution testing in an artificial salivary fluid and investigations using e-tongue, to assess the extent of masking of bitter taste of the API. There was an insignificant amount of drug released from the formulation in the salivary medium while over 80% of drug released within 30 min in 0.1 N HCl. ODTs were also developed with the extrudate mixed with mannitol and crospovidone. The quality properties such as friability and disintegration time of the ODTs met the USP specifications. The lead extrudate formulations and the ODTs prepared using this formulation were subjected to human gustatory evaluation. The formulations were found to mask the unpleasant taste of caffeine citrate significantly. PMID:25888797

  17. Application of dry elixir system to oriental traditional medicine: taste masking of peonjahwan by coated dry elixir.

    PubMed

    Choi, H G; Kim, C K

    2000-02-01

    Peonjahwan, an oriental traditional medicine composed of crude herbal drugs and animal tissues is bitter and poorly water-soluble. To mask the bitterness of peonjahwan and enhance the release of bilirubin, one of the crude active ingredients of peonjahwan, peonja dry elixir (PDE), was prepared using a spray-dryer after extracting the crude materials in ethanol-water solution. Coated peonja dry elixir (CPDE) was then prepared by coating the PDE with Eudragit acrylic resin. Panel assessed bitterness and release test of bilirubin from PDE and CPDE were carried out and compared with peonjahwan alone. PDE was found to have little effect upon the reduction of the bitterness of peonjahwan. However, the bitterness of CPDE was found to reduce to 1/4 of that of peonjahwan due to the encapsulation of crude active ingredients by the dextrin and Eudragit shell (P<0.05). The release rate of bilirubin from PDE and CPDE for 60 min increased about 3.5- and 2.5- fold, respectively, compared to peonjahwan at pH 1.2. It is concluded that CPDE, which masked the bitterness of peonjahwan and enhanced the release of bilirubin, is a preferable delivery system for peonjahwan.

  18. 46 CFR 197.346 - Diver's equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... using SCUBA must have— (1) Self-contained underwater breathing equipment including— (i) A primary..., gloves, shoes, weight assembly, and knife; (3) Have a hose group consisting of the breathing gas hose and... assembly capable of quick release; (3) A mask group consisting of a lightweight mask and associated valves...

  19. Formulation and evaluation of sublingual tablets containing Sumatriptan succinate

    PubMed Central

    Prajapati, Shailesh T; Patel, Parth B; Patel, Chhagan N

    2012-01-01

    Objective: Sumatriptan succinate is a selective 5-hydroxytryptamine-1 receptor agonist effective in the acute treatment of migraine headaches, having low bioavailability of about 15% orally due to first-pass metabolism. The purpose of this research was to mask the intensely bitter taste of Sumatriptan succinate and to formulate fast-acting, taste-masked sublingual tablet formulation. Materials and Methods: Taste masking was performed by solid dispersion method with mannitol and ion exchange with Kyron T 114 because it releases the drug in salivary pH. The resultant batches were evaluated for in-vivo taste masking as well compatability study (Fourier transform infrared (FTIR) and differential scanning calorimetry (DSC)). For a better feel in the mouth, menthol and sweetener Na saccharine were added to the tablet formulation. The tablets were prepared by direct compression and evaluated for weight variation, thickness, friability, drug content, hardness, disintegration time, wetting time, in vitro drug release, and in vitro permeation study. Results and Discussion: Optimized batches disintegrated in vitro within 28-34 s. Maximum drug release could be achieved with in 10 min for the solid dispersion batches and 14-15 min for the ion-exchange batches with Kyron T 114. The optimized tablet formulation showed better taste and the formulated sublingual tablets may act as a potential alternate for the Sumatriptan succinate oral tablet. Conclusion: Sumatriptan succinate can be successfully taste-masked by both the solid dispersion method using mannitol by the melting method and Ion exchange resin with Kyron T114. It was also concluded that prepared formulation improve bioavailability by prevention of first pass metabolism. PMID:23373008

  20. Informational Masking and Spatial Hearing in Listeners with and without Unilateral Hearing Loss

    ERIC Educational Resources Information Center

    Rothpletz, Ann M.; Wightman, Frederic L.; Kistler, Doris J.

    2012-01-01

    Purpose: This study assessed selective listening for speech in individuals with and without unilateral hearing loss (UHL) and the potential relationship between spatial release from informational masking and localization ability in listeners with UHL. Method: Twelve adults with UHL and 12 normal-hearing controls completed a series of monaural and…

  1. Binaural Release from Masking for a Speech Sound in Infants, Preschoolers, and Adults.

    ERIC Educational Resources Information Center

    Nozza, Robert J.

    1988-01-01

    Binaural masked thresholds for a speech sound (/ba/) were estimated under two interaural phase conditions in three age groups (infants, preschoolers, adults). Differences as a function of both age and condition and effects of reducing intensity for adults were significant in indicating possible developmental binaural hearing changes, especially…

  2. Masking Release for Igbo and English.

    PubMed

    Ebem, Deborah U; Desloge, Joseph G; Reed, Charlotte M; Braida, Louis D; Uguru, Joy O

    2013-09-01

    In this research, we explored the effect of noise interruption rate on speech intelligibility. Specifically, we used the Hearing In Noise Test (HINT) procedure with the original HINT stimuli (English) and Igbo stimuli to assess speech reception ability in interrupted noise. For a given noise level, the HINT test provides an estimate of the signal-to-noise ratio (SNR) required for 50%-correct speech intelligibility. The SNR for 50%-correct intelligibility changes depending upon the interruption rate of the noise. This phenomenon (called Masking Release) has been studied extensively in English but not for Igbo - which is an African tonal language spoken predominantly in South Eastern Nigeria. This experiment explored and compared the phenomenon of Masking Release for (i) native English speakers listening to English, (ii) native Igbo speakers listening to English, and (iii) native Igbo speakers listening to Igbo. Since Igbo is a tonal language and English is a non-tonal language, this allowed us to compare Masking Release patterns on native speakers of tonal and non-tonal languages. Our results for native English speakers listening to English HINT show that the SNR and the masking release are orderly and consistent with other English HINT data for English speakers. Our result for Igbo speakers listening to English HINT sentences show that there is greater variability in results across the different Igbo listeners than across the English listeners. This result likely reflects different levels of ability in the English language across the Igbo listeners. The masking release values in dB are less than for English listeners. Our results for Igbo speakers listening to Igbo show that in general, the SNRs for Igbo sentences are lower than for English/English and Igbo/English. This means that the Igbo listeners could understand 50% of the Igbo sentences at SNRs less than those required for English sentences by either native or non-native listeners. This result can be explained by the fact that the perception of Igbo utterances by Igbo subjects may have been aided by the prediction of tonal and vowel harmony features existent in the Igbo language. In agreement with other studies, our results also show that in a noisy environment listeners are able to perceive their native language better than a second language. The ability of native language speakers to perceive their language better than a second language in a noisy environment may be attributed to the fact that: Native speakers are more familiar with the sounds of their language than second language speakers.One of the features of language is that it is predictable hence even in noise a native speaker may be able to predict a succeeding word that is scarcely audible. These contextual effects are facilitated by familiarity.

  3. Neural correlates of binaural masking level difference in the inferior colliculus of the barn owl (Tyto alba).

    PubMed

    Asadollahi, Ali; Endler, Frank; Nelken, Israel; Wagner, Hermann

    2010-08-01

    Humans and animals are able to detect signals in noisy environments. Detection improves when the noise and the signal have different interaural phase relationships. The resulting improvement in detection threshold is called the binaural masking level difference. We investigated neural mechanisms underlying the release from masking in the inferior colliculus of barn owls in low-frequency and high-frequency neurons. A tone (signal) was presented either with the same interaural time difference as the noise (masker) or at a 180 degrees phase shift as compared with the interaural time difference of the noise. The changes in firing rates induced by the addition of a signal of increasing level while masker level was kept constant was well predicted by the relative responses to the masker and signal alone. In many cases, the response at the highest signal levels was dominated by the response to the signal alone, in spite of a significant response to the masker at low signal levels, suggesting the presence of occlusion. Detection thresholds and binaural masking level differences were widely distributed. The amount of release from masking increased with increasing masker level. Narrowly tuned neurons in the central nucleus of the inferior colliculus had detection thresholds that were lower than or similar to those of broadly tuned neurons in the external nucleus of the inferior colliculus. Broadly tuned neurons exhibited higher masking level differences than narrowband neurons. These data suggest that detection has different spectral requirements from localization.

  4. The impact of a parkinsonian lesion on dynamic striatal dopamine transmission depends on nicotinic receptor activation

    PubMed Central

    Jennings, Katie A.; Platt, Nicola J.; Cragg, Stephanie J.

    2015-01-01

    Dopamine function is disturbed in Parkinson's disease (PD), but whether and how release of dopamine from surviving neurons is altered has long been debated. Nicotinic acetylcholine receptors (nAChRs) on dopamine axons powerfully govern dopamine release and could be critical contributing factors. We revisited whether fundamental properties of dopamine transmission are changed in a parkinsonian brain and tested the potentially profound masking effects of nAChRs. Using real-time detection of dopamine in mouse striatum after a partial 6-hydroxydopamine lesion and under nAChR inhibition, we reveal that dopamine signals show diminished sensitivity to presynaptic activity. This effect manifested as diminished contrast between DA release evoked by the lowest versus highest frequencies. This reduced activity-dependence was underpinned by loss of short-term facilitation of dopamine release, consistent with an increase in release probability (Pr). With nAChRs active, the reduced activity-dependence of dopamine release after a parkinsonian lesion was masked. Consequently, moment-by-moment variation in activity of nAChRs may lead to dynamic co-variation in dopamine signal impairments in PD. PMID:26117304

  5. Formulation development and evaluation of metformin chewing gum with bitter taste masking

    PubMed Central

    Mostafavi, Sayed Abolfazl; Varshosaz, Jaleh; Arabian, Saber

    2014-01-01

    Background: Medicated gums are intended to be chewed and act either locally, absorbed via the buccal mucosa or swallowed with saliva. We prepared the metformin gum to overcome its side effects including vomiting, diarrhea, and abdomen discomfort. Furthermore, it could be useful for those who have swallowing problems. Materials and Methods: Metformin hydrochloride (250 mg) with suitable sweeteners was mixed manually for 5 min. This mixture was spray dried, freeze dried, or directly mixed with chewing gum base. Glycerin, xylitol, and menthol were added and the produced paste was kept in the freezer for 2 h to be stable. As the metformin shows bitter taste, we tried to mask this unpleasant taste with using different methods explained. The releasing pattern was evaluated by using a mechanical chewing machine. The best formulation with the optimized releasing pattern, suitable physicochemical properties and pleasant taste were selected. Content uniformity, releasing percent, and other physicochemical properties were identified as well. Taste, flavor, and appearance characteristics were evaluated by using a self-made questionnaire based on the hedonic test method. Results: The chewing gum dosage content was about 86.2%. The release rate of metformin chewing gum was about 70% after 5 min of mastication. Masking the bitter taste of drug was achieved by using acesulfame-isomalt as sweeteners and prepared it by freeze drying equipment. Conclusion: Metfornin chewing gum had suitable appearance and appropriate invitro characteristics that fallow the pharmacopeia suggestions. This chewable gum showed bitterness suppression with a suitable release rate. PMID:24800181

  6. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    PubMed

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.

  7. Rapidly disintegrating tablets containing taste masked metoclopramide hydrochloride prepared by extrusion-precipitation method.

    PubMed

    Randale, Shivsagar Ashok; Dabhi, Chandu Somatbhai; Tekade, Avinash Ramrao; Belgamwar, Veena Shailendra; Gattani, Surendra Ganeshlal; Surana, Sanjay Javarilal

    2010-04-01

    The purpose of this study was to mask the intensely bitter taste of metoclopramide HCl and to formulate a rapid disintegrating tablet (RDT) of the taste-masked drug. Taste masking was done by complexing metoclopramide HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratio by the extrusion-precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.8, taste evaluation in oral cavity and molecular property. The complex having drug-polymer ratio of 1 : 2 shows significant taste masking, confirmed by drug release in SSF and in-vivo taste evaluation; therefore, it was selected for further study. Taste evaluation of DPCs in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) within 10 s, whereas, metoclopramide HCl was rated intensely bitter with a score of +3 for 10 s. Tablets were evaluated for various parameters like tensile strength, wetting time, water absorption ratio, in-vitro disintegration time, and disintegration in oral cavity. The effect of diluents, lubricants and sweetening agent (Xylisorb) on the disintegration time was also evaluated. Tablets of batch F3 containing mannitol and microcrystalline cellulose in the ratio 1 : 1 and 8% w/w crosspovidone showed faster disintegration (within 20 s) than the marketed formulation (180 s). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Tablets of batch F3 also revealed rapid drug release (t(90), 90 s) in SGF compared with marketed formulation (t(90), 600 s).

  8. Masking release with changing fundamental frequency: Electric acoustic stimulation resembles normal hearing subjects.

    PubMed

    Auinger, Alice Barbara; Riss, Dominik; Liepins, Rudolfs; Rader, Tobias; Keck, Tilman; Keintzel, Thomas; Kaider, Alexandra; Baumgartner, Wolf-Dieter; Gstoettner, Wolfgang; Arnoldner, Christoph

    2017-07-01

    It has been shown that patients with electric acoustic stimulation (EAS) perform better in noisy environments than patients with a cochlear implant (CI). One reason for this could be the preserved access to acoustic low-frequency cues including the fundamental frequency (F0). Therefore, our primary aim was to investigate whether users of EAS experience a release from masking with increasing F0 difference between target talker and masking talker. The study comprised 29 patients and consisted of three groups of subjects: EAS users, CI users and normal-hearing listeners (NH). All CI and EAS users were implanted with a MED-EL cochlear implant and had at least 12 months of experience with the implant. Speech perception was assessed with the Oldenburg sentence test (OlSa) using one sentence from the test corpus as speech masker. The F0 in this masking sentence was shifted upwards by 4, 8, or 12 semitones. For each of these masker conditions the speech reception threshold (SRT) was assessed by adaptively varying the masker level while presenting the target sentences at a fixed level. A statistically significant improvement in speech perception was found for increasing difference in F0 between target sentence and masker sentence in EAS users (p = 0.038) and in NH listeners (p = 0.003). In CI users (classic CI or EAS users with electrical stimulation only) speech perception was independent from differences in F0 between target and masker. A release from masking with increasing difference in F0 between target and masking speech was only observed in listeners and configurations in which the low-frequency region was presented acoustically. Thus, the speech information contained in the low frequencies seems to be crucial for allowing listeners to separate multiple sources. By combining acoustic and electric information, EAS users even manage tasks as complicated as segregating the audio streams from multiple talkers. Preserving the natural code, like fine-structure cues in the low-frequency region, seems to be crucial to provide CI users with the best benefit. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    PubMed Central

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179

  10. Atypical audio-visual speech perception and McGurk effects in children with specific language impairment

    PubMed Central

    Leybaert, Jacqueline; Macchi, Lucie; Huyse, Aurélie; Champoux, François; Bayard, Clémence; Colin, Cécile; Berthommier, Frédéric

    2014-01-01

    Audiovisual speech perception of children with specific language impairment (SLI) and children with typical language development (TLD) was compared in two experiments using /aCa/ syllables presented in the context of a masking release paradigm. Children had to repeat syllables presented in auditory alone, visual alone (speechreading), audiovisual congruent and incongruent (McGurk) conditions. Stimuli were masked by either stationary (ST) or amplitude modulated (AM) noise. Although children with SLI were less accurate in auditory and audiovisual speech perception, they showed similar auditory masking release effect than children with TLD. Children with SLI also had less correct responses in speechreading than children with TLD, indicating impairment in phonemic processing of visual speech information. In response to McGurk stimuli, children with TLD showed more fusions in AM noise than in ST noise, a consequence of the auditory masking release effect and of the influence of visual information. Children with SLI did not show this effect systematically, suggesting they were less influenced by visual speech. However, when the visual cues were easily identified, the profile of responses to McGurk stimuli was similar in both groups, suggesting that children with SLI do not suffer from an impairment of audiovisual integration. An analysis of percent of information transmitted revealed a deficit in the children with SLI, particularly for the place of articulation feature. Taken together, the data support the hypothesis of an intact peripheral processing of auditory speech information, coupled with a supra modal deficit of phonemic categorization in children with SLI. Clinical implications are discussed. PMID:24904454

  11. Atypical audio-visual speech perception and McGurk effects in children with specific language impairment.

    PubMed

    Leybaert, Jacqueline; Macchi, Lucie; Huyse, Aurélie; Champoux, François; Bayard, Clémence; Colin, Cécile; Berthommier, Frédéric

    2014-01-01

    Audiovisual speech perception of children with specific language impairment (SLI) and children with typical language development (TLD) was compared in two experiments using /aCa/ syllables presented in the context of a masking release paradigm. Children had to repeat syllables presented in auditory alone, visual alone (speechreading), audiovisual congruent and incongruent (McGurk) conditions. Stimuli were masked by either stationary (ST) or amplitude modulated (AM) noise. Although children with SLI were less accurate in auditory and audiovisual speech perception, they showed similar auditory masking release effect than children with TLD. Children with SLI also had less correct responses in speechreading than children with TLD, indicating impairment in phonemic processing of visual speech information. In response to McGurk stimuli, children with TLD showed more fusions in AM noise than in ST noise, a consequence of the auditory masking release effect and of the influence of visual information. Children with SLI did not show this effect systematically, suggesting they were less influenced by visual speech. However, when the visual cues were easily identified, the profile of responses to McGurk stimuli was similar in both groups, suggesting that children with SLI do not suffer from an impairment of audiovisual integration. An analysis of percent of information transmitted revealed a deficit in the children with SLI, particularly for the place of articulation feature. Taken together, the data support the hypothesis of an intact peripheral processing of auditory speech information, coupled with a supra modal deficit of phonemic categorization in children with SLI. Clinical implications are discussed.

  12. Solutions to the cocktail party problem in insects: selective filters, spatial release from masking and gain control in tropical crickets.

    PubMed

    Schmidt, Arne K D; Römer, Heiner

    2011-01-01

    Insects often communicate by sound in mixed species choruses; like humans and many vertebrates in crowded social environments they thus have to solve cocktail-party-like problems in order to ensure successful communication with conspecifics. This is even more a problem in species-rich environments like tropical rainforests, where background noise levels of up to 60 dB SPL have been measured. Using neurophysiological methods we investigated the effect of natural background noise (masker) on signal detection thresholds in two tropical cricket species Paroecanthus podagrosus and Diatrypa sp., both in the laboratory and outdoors. We identified three 'bottom-up' mechanisms which contribute to an excellent neuronal representation of conspecific signals despite the masking background. First, the sharply tuned frequency selectivity of the receiver reduces the amount of masking energy around the species-specific calling song frequency. Laboratory experiments yielded an average signal-to-noise ratio (SNR) of -8 dB, when masker and signal were broadcast from the same side. Secondly, displacing the masker by 180° from the signal improved SNRs by further 6 to 9 dB, a phenomenon known as spatial release from masking. Surprisingly, experiments carried out directly in the nocturnal rainforest yielded SNRs of about -23 dB compared with those in the laboratory with the same masker, where SNRs reached only -14.5 and -16 dB in both species. Finally, a neuronal gain control mechanism enhances the contrast between the responses to signals and the masker, by inhibition of neuronal activity in interstimulus intervals. Thus, conventional speaker playbacks in the lab apparently do not properly reconstruct the masking noise situation in a spatially realistic manner, since under real world conditions multiple sound sources are spatially distributed in space. Our results also indicate that without knowledge of the receiver properties and the spatial release mechanisms the detrimental effect of noise may be strongly overestimated.

  13. Solutions to the Cocktail Party Problem in Insects: Selective Filters, Spatial Release from Masking and Gain Control in Tropical Crickets

    PubMed Central

    Schmidt, Arne K. D.; Römer, Heiner

    2011-01-01

    Background Insects often communicate by sound in mixed species choruses; like humans and many vertebrates in crowded social environments they thus have to solve cocktail-party-like problems in order to ensure successful communication with conspecifics. This is even more a problem in species-rich environments like tropical rainforests, where background noise levels of up to 60 dB SPL have been measured. Principal Findings Using neurophysiological methods we investigated the effect of natural background noise (masker) on signal detection thresholds in two tropical cricket species Paroecanthus podagrosus and Diatrypa sp., both in the laboratory and outdoors. We identified three ‘bottom-up’ mechanisms which contribute to an excellent neuronal representation of conspecific signals despite the masking background. First, the sharply tuned frequency selectivity of the receiver reduces the amount of masking energy around the species-specific calling song frequency. Laboratory experiments yielded an average signal-to-noise ratio (SNR) of −8 dB, when masker and signal were broadcast from the same side. Secondly, displacing the masker by 180° from the signal improved SNRs by further 6 to 9 dB, a phenomenon known as spatial release from masking. Surprisingly, experiments carried out directly in the nocturnal rainforest yielded SNRs of about −23 dB compared with those in the laboratory with the same masker, where SNRs reached only −14.5 and −16 dB in both species. Finally, a neuronal gain control mechanism enhances the contrast between the responses to signals and the masker, by inhibition of neuronal activity in interstimulus intervals. Conclusions Thus, conventional speaker playbacks in the lab apparently do not properly reconstruct the masking noise situation in a spatially realistic manner, since under real world conditions multiple sound sources are spatially distributed in space. Our results also indicate that without knowledge of the receiver properties and the spatial release mechanisms the detrimental effect of noise may be strongly overestimated. PMID:22163041

  14. Tannate complexes of antihistaminic drug: sustained release and taste masking approaches.

    PubMed

    Rahman, Ziyaur; Zidan, Ahmed S; Berendt, Robert T; Khan, Mansoor A

    2012-01-17

    The aim of this investigation was to evaluate the complexation potential of brompheniramine maleate (BPM) and tannic acid (TA) for sustained release and taste masking effects. The complexes (1:1-1:7 TA to BPM ratio) were prepared by the solvent evaporation method using methanol, phosphate buffer pH 6.8 or 0.1N HCl as common solvents. The complexes were characterized microscopically by scanning electron microscopy (SEM), chemically by Fourier transform infrared (FTIR) and solid-state NMR (SSNMR), thermally by differential scanning calorimetry (DSC), for crystallinity by powder X-ray powder diffraction (PXRD), for organoleptic evaluation by electronic tongue (e-tongue), and for solubility in 0.1N HCl and phosphate buffer pH 6.8. The dissolution studies were carried out using the USP II method at 50 rpm in 500 ml of dissolution media (0.1N HCl or phosphate buffer pH 6.8). SEM images revealed that the morphology of complexes were completely different from the individual components, and all complexes had the same morphological characteristics, irrespective of the solvent used for their preparation, pH or ratio of BPM and TA. The FTIR spectra showed the presence of chemical interactions between the TA and BPM. DSC, PXRD and SSNMR indicated that the drug lost its crystalline nature by formation of the complex. Complexation has significantly reduced the solubility of BPM and sustained the drug release up to 24h in phosphate buffer pH 6.8 media. The bitter taste of the BPM was completely masked which was indicated by Euclidean distance values which was far from the drug but near to its placebo in the complexes in all ratios studied. The taste masked complexes can be potentially developed as suitable dosage forms for pediatric use. In summary, complexation of BPM and TA effectively sustained the dissolution and masked the bitter taste of drug for the development of suitable dosage forms for pediatric use. Published by Elsevier B.V.

  15. Neural Correlates and Mechanisms of Spatial Release From Masking: Single-Unit and Population Responses in the Inferior Colliculus

    PubMed Central

    Lane, Courtney C.; Delgutte, Bertrand

    2007-01-01

    Spatial release from masking (SRM), a factor in listening in noisy environments, is the improvement in auditory signal detection obtained when a signal is separated in space from a masker. To study the neural mechanisms of SRM, we recorded from single units in the inferior colliculus (IC) of barbiturate-anesthetized cats, focusing on low-frequency neurons sensitive to interaural time differences. The stimulus was a broadband chirp train with a 40-Hz repetition rate in continuous broadband noise, and the unit responses were measured for several signal and masker (virtual) locations. Masked thresholds (the lowest signal-to-noise ratio, SNR, for which the signal could be detected for 75% of the stimulus presentations) changed systematically with signal and masker location. Single-unit thresholds did not necessarily improve with signal and masker separation; instead, they tended to reflect the units’ azimuth preference. Both how the signal was detected (through a rate increase or decrease) and how the noise masked the signal response (suppressive or excitatory masking) changed with signal and masker azimuth, consistent with a cross-correlator model of binaural processing. However, additional processing, perhaps related to the signal’s amplitude modulation rate, appeared to influence the units’ responses. The population masked thresholds (the most sensitive unit’s threshold at each signal and masker location) did improve with signal and masker separation as a result of the variety of azimuth preferences in our unit sample. The population thresholds were similar to human behavioral thresholds in both SNR value and shape, indicating that these units may provide a neural substrate for low-frequency SRM. PMID:15857966

  16. Consonant identification in noise using Hilbert-transform temporal fine-structure speech and recovered-envelope speech for listeners with normal and impaired hearinga)

    PubMed Central

    Léger, Agnès C.; Reed, Charlotte M.; Desloge, Joseph G.; Swaminathan, Jayaganesh; Braida, Louis D.

    2015-01-01

    Consonant-identification ability was examined in normal-hearing (NH) and hearing-impaired (HI) listeners in the presence of steady-state and 10-Hz square-wave interrupted speech-shaped noise. The Hilbert transform was used to process speech stimuli (16 consonants in a-C-a syllables) to present envelope cues, temporal fine-structure (TFS) cues, or envelope cues recovered from TFS speech. The performance of the HI listeners was inferior to that of the NH listeners both in terms of lower levels of performance in the baseline condition and in the need for higher signal-to-noise ratio to yield a given level of performance. For NH listeners, scores were higher in interrupted noise than in steady-state noise for all speech types (indicating substantial masking release). For HI listeners, masking release was typically observed for TFS and recovered-envelope speech but not for unprocessed and envelope speech. For both groups of listeners, TFS and recovered-envelope speech yielded similar levels of performance and consonant confusion patterns. The masking release observed for TFS and recovered-envelope speech may be related to level effects associated with the manner in which the TFS processing interacts with the interrupted noise signal, rather than to the contributions of TFS cues per se. PMID:26233038

  17. Strategy optimization for mask rule check in wafer fab

    NASA Astrophysics Data System (ADS)

    Yang, Chuen Huei; Lin, Shaina; Lin, Roger; Wang, Alice; Lee, Rachel; Deng, Erwin

    2015-07-01

    Photolithography process is getting more and more sophisticated for wafer production following Moore's law. Therefore, for wafer fab, consolidated and close cooperation with mask house is a key to achieve silicon wafer success. However, generally speaking, it is not easy to preserve such partnership because many engineering efforts and frequent communication are indispensable. The inattentive connection is obvious in mask rule check (MRC). Mask houses will do their own MRC at job deck stage, but the checking is only for identification of mask process limitation including writing, etching, inspection, metrology, etc. No further checking in terms of wafer process concerned mask data errors will be implemented after data files of whole mask are composed in mask house. There are still many potential data errors even post-OPC verification has been done for main circuits. What mentioned here are the kinds of errors which will only occur as main circuits combined with frame and dummy patterns to form whole reticle. Therefore, strategy optimization is on-going in UMC to evaluate MRC especially for wafer fab concerned errors. The prerequisite is that no impact on mask delivery cycle time even adding this extra checking. A full-mask checking based on job deck in gds or oasis format is necessary in order to secure acceptable run time. Form of the summarized error report generated by this checking is also crucial because user friendly interface will shorten engineers' judgment time to release mask for writing. This paper will survey the key factors of MRC in wafer fab.

  18. Taste Masking of Griseofulvin and Caffeine Anhydrous Using Kleptose Linecaps DE17 by Hot Melt Extrusion.

    PubMed

    Juluri, Abhishek; Popescu, Carmen; Zhou, Leon; Murthy, Reena N; Gowda, Vanaja K; Chetan Kumar, P; Pimparade, Manjeet B; Repka, Michael A; Murthy, S Narasimha

    2016-02-01

    The objective of this project was to investigate the potential of Kleptose Linecaps DE17 (KLD) in masking the unpleasant/bitter taste of therapeutic agents by hot melt extrusion (HME). Griseofulvin (GRI) and caffeine anhydrous (CA) were used as a bitter active pharmaceutical ingredient (API) model drugs. Thermogravimetric studies confirmed the stability of GRI, CA, and KLD at the employed extrusion temperatures. The differential scanning calorimetry (DSC) studies revealed a characteristic melting endotherm of GRI at 218-220°C and CA at 230-232°C in the physical mixtures as well as in all extrudates over the period of study, indicating the crystalline nature of drug. HME of KLD was achieved only in the presence of plasticizer. Among the several plasticizers investigated, xylitol showed improved processability of KLD at 15% w/w concentration. Dissolution studies of HME extrudates using simulated salivary medium exhibited ∼threefold less release compared to physical mixture at the end of 5 min (the lesser drug release, better the taste masking efficiency). Furthermore, the results from the sensory evaluation of products in human panel demonstrated strong bitter taste in the case of physical mixture compared to the HME formulation, suggesting the potential of Kleptose Linecaps DE17 as taste masking polymer in melt extruded form.

  19. Original research paper. Characterization and taste masking evaluation of microparticles with cetirizine dihydrochloride and methacrylate-based copolymer obtained by spray drying.

    PubMed

    Amelian, Aleksandra; Szekalska, Marta; Ciosek, Patrycja; Basa, Anna; Winnicka, Katarzyna

    2017-03-01

    Taste of a pharmaceutical formulation is an important parameter for the effectiveness of pharmacotherapy. Cetirizine dihydrochloride (CET) is a second-generation antihistamine that is commonly administered in allergy treatment. CET is characterized by extremely bitter taste and it is a great challenge to successfully mask its taste; therefore the goal of this work was to formulate and characterize the microparticles obtained by the spray drying method with CET and poly(butyl methacrylate-co-(2-dimethylaminoethyl) methacrylate-co-methyl methacrylate 1:2:1 copolymer (Eudragit E PO) as a barrier coating. Assessment of taste masking by the electronic tongue has revealed that designed formulations created an effective taste masking barrier. Taste masking effect was also confirmed by the in vivo model and the in vitro release profile of CET. Obtained data have shown that microparticles with a drug/polymer ratio (0.5:1) are promising CET carriers with efficient taste masking potential and might be further used in designing orodispersible dosage forms with CET.

  20. Combination of binaural and harmonic masking release effects in the detection of a single component in complex tones.

    PubMed

    Klein-Hennig, Martin; Dietz, Mathias; Hohmann, Volker

    2018-03-01

    Both harmonic and binaural signal properties are relevant for auditory processing. To investigate how these cues combine in the auditory system, detection thresholds for an 800-Hz tone masked by a diotic (i.e., identical between the ears) harmonic complex tone were measured in six normal-hearing subjects. The target tone was presented either diotically or with an interaural phase difference (IPD) of 180° and in either harmonic or "mistuned" relationship to the diotic masker. Three different maskers were used, a resolved and an unresolved complex tone (fundamental frequency: 160 and 40 Hz) with four components below and above the target frequency and a broadband unresolved complex tone with 12 additional components. The target IPD provided release from masking in most masker conditions, whereas mistuning led to a significant release from masking only in the diotic conditions with the resolved and the narrowband unresolved maskers. A significant effect of mistuning was neither found in the diotic condition with the wideband unresolved masker nor in any of the dichotic conditions. An auditory model with a single analysis frequency band and different binaural processing schemes was employed to predict the data of the unresolved masker conditions. Sensitivity to modulation cues was achieved by including an auditory-motivated modulation filter in the processing pathway. The predictions of the diotic data were in line with the experimental results and literature data in the narrowband condition, but not in the broadband condition, suggesting that across-frequency processing is involved in processing modulation information. The experimental and model results in the dichotic conditions show that the binaural processor cannot exploit modulation information in binaurally unmasked conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Neural Correlates of Auditory Perceptual Awareness and Release from Informational Masking Recorded Directly from Human Cortex: A Case Study.

    PubMed

    Dykstra, Andrew R; Halgren, Eric; Gutschalk, Alexander; Eskandar, Emad N; Cash, Sydney S

    2016-01-01

    In complex acoustic environments, even salient supra-threshold sounds sometimes go unperceived, a phenomenon known as informational masking. The neural basis of informational masking (and its release) has not been well-characterized, particularly outside auditory cortex. We combined electrocorticography in a neurosurgical patient undergoing invasive epilepsy monitoring with trial-by-trial perceptual reports of isochronous target-tone streams embedded in random multi-tone maskers. Awareness of such masker-embedded target streams was associated with a focal negativity between 100 and 200 ms and high-gamma activity (HGA) between 50 and 250 ms (both in auditory cortex on the posterolateral superior temporal gyrus) as well as a broad P3b-like potential (between ~300 and 600 ms) with generators in ventrolateral frontal and lateral temporal cortex. Unperceived target tones elicited drastically reduced versions of such responses, if at all. While it remains unclear whether these responses reflect conscious perception, itself, as opposed to pre- or post-perceptual processing, the results suggest that conscious perception of target sounds in complex listening environments may engage diverse neural mechanisms in distributed brain areas.

  2. Advanced stable lipid-based formulations for a patient-centric product design.

    PubMed

    Becker, Karin; Saurugger, Eva-Maria; Kienberger, Diana; Lopes, Diogo; Haack, Detlev; Köberle, Martin; Stehr, Michael; Lochmann, Dirk; Zimmer, Andreas; Salar-Behzadi, Sharareh

    2016-01-30

    Multiparticulate dosage forms are a recent strategy to meet the special needs of children, elderly people and patients suffering from dysphagia. Our study presents a novel and cost-efficient approach for the manufacturing of a taste-masked multiparticulate system with a stable immediate release profile by applying lipid-based excipients in a solvent-free hot melt coating process. The thermosensitive N-acetylcysteine (N-ac) was used as model drug and hot-melt coated with a mixture of tripalmitin and polysorbate 65. A predictive in vitro method for the evaluation of the taste masking efficiency was developed based on the deprotonation of the carboxyl group of N-ac and the decline of pH, responsible for the unpleasant sour taste of the compound. The method was confirmed using in vivo studies. Differential scanning calorimetry and X-ray scattering experiments revealed polymorphic transformation and its dependency on transformation time, temperature and emulsifier concentration. During the process, the coating was transformed almost completely into the stable β-polymorph, leading to an unaltered dissolution profile during storage. A statistical design was conducted that revealed the critical process parameters affecting the taste masking efficiency and drug release. This study shows the successful application of solvent-free hot-melt coating in the development of a taste-masked and stable formulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Orodispersible films and tablets with prednisolone microparticles.

    PubMed

    Brniak, Witold; Maślak, Ewelina; Jachowicz, Renata

    2015-07-30

    Orodispersible tablets (ODTs) and orodispersible films (ODFs) are solid oral dosage forms disintegrating or dissolving rapidly when placed in the mouth. One of the main issues related to their preparation is an efficient taste masking of a bitter drug substance. Therefore, the aim of this study was to prepare and evaluate the microparticles intended to mask a bitter taste of the prednisolone and use them in further preparation of two orodispersible dosage forms. Microparticles based on the Eudragit E PO or E 100 as a taste-masking agent were prepared with spray-drying technique. Tablets containing microparticles, co-processed ODT excipient Pharmaburst, and lubricant were directly compressed with single-punch tablet press. Orodispersible films were prepared by casting polymeric solutions of hydroxypropyl methylcellulose containing uniformly dispersed microparticles. Physicochemical properties of microparticles were evaluated, as well as mechanical properties analysis, disintegration time measurements and dissolution tests were performed for prepared dosage forms. Both formulations showed good mechanical resistance while maintaining excellent disintegration properties. The dissolution studies showed good masking properties of microparticles with Eudragit E 100. The amount of prednisolone released during the first minute in phosphate buffer 6.8 was around 0.1%. After incorporation into the orodispersible forms, the amount of released prednisolone increased significantly. It was probably the effect of faster microparticles wetting in orodispersible forms and their partial destruction by compression force during tableting process. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and nonnative english speakers.

    PubMed

    Calandruccio, Lauren; Bradlow, Ann R; Dhar, Sumitrajit

    2014-04-01

    Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared with native-accented English speech was reported in Calandruccio et al (2010a). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech Affiliationect masking release. A mixed-model design with within-subject (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech and high-intelligibility, moderate-intelligibility, and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Three listener groups were tested, including monolingual English speakers with normal hearing, nonnative English speakers with normal hearing, and monolingual English speakers with hearing loss. The nonnative English speakers were from various native language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetric mild sloping to moderate sensorineural hearing loss. Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the key words within the sentences (100 key words per masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and listener groups. Monolingual English speakers with normal hearing benefited when the competing speech signal was foreign accented compared with native accented, allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the nonnative English-speaking listeners with normal hearing nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Slight modifications between the target and the masker speech allowed monolingual English speakers with normal hearing to improve their recognition of native-accented English, even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. American Academy of Audiology.

  5. 75 FR 71536 - Airworthiness Directives; SOCATA Model TBM 700 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-24

    ... difficulties for the pilot to release oxygen. After investigation it was found that, due to the design of the oxygen generator release pin, one of the mask's lanyard linked to the pin could be jammed when it is... procedure due to decompression, to a risk of generator fault with subsequent lack of oxygen on crew and/or...

  6. 75 FR 52480 - Airworthiness Directives; SOCATA Model TBM 700 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-26

    ... difficulties for the pilot to release oxygen. After investigation it was found that, due to the design of the oxygen generator release pin, one of the mask's lanyard linked to the pin could be jammed when it is... procedure due to decompression, to a risk of generator fault with subsequent lack of oxygen on crew and/or...

  7. Do Plant-Bound Masked Mycotoxins Contribute to Toxicity?

    PubMed Central

    Gratz, Silvia W.

    2017-01-01

    Masked mycotoxins are plant metabolites of mycotoxins which co-contaminate common cereal crops. Since their discovery, the question has arisen if they contribute to toxicity either directly or indirectly through the release of the parent mycotoxins. Research in this field is rapidly emerging and the aim of this review is to summarize the latest knowledge on the fate of masked mycotoxins upon ingestion. Fusarium mycotoxins are the most prevalent masked mycotoxins and evidence is mounting that DON3Glc and possibly other masked trichothecenes are stable in conditions prevailing in the upper gut and are not absorbed intact. DON3Glc is also not toxic per se, but is hydrolyzed by colonic microbes and further metabolized to DOM-1 in some individuals. Masked zearalenone is rather more bio-reactive with some evidence on gastric and small intestinal hydrolysis as well as hydrolysis by intestinal epithelium and components of blood. Microbial hydrolysis of ZEN14Glc is almost instantaneous and further metabolism also occurs. Identification of zearalenone metabolites and their fate in the colon are still missing as is further clarification on whether or not masked zearalenone is hydrolyzed by mammalian cells. New masked mycotoxins continuously emerge and it is crucial that we gain detailed understanding of their individual metabolic fate in the body before we can assess synergistic effects and extrapolate the additive risk of all mycotoxins present in food. PMID:28264486

  8. Human frequency-following response to speech-like sounds: correlates of off-frequency masking.

    PubMed

    Krishnan, Ananthanarayan; Agrawal, Smita

    2010-01-01

    Off-frequency masking of the second formant by energy at the first formant has been shown to influence both identification and discrimination of the second formant in normal-hearing and hearing-impaired listeners. While both excitatory spread and two-tone suppression have been implicated in this simultaneous masking, their relative contribution has been shown to depend on both the level of the masker and the frequency separation between the probe and the masker. Off-frequency masking effects were evaluated in 10 normal-hearing human adults using the frequency-following response (FFR) to two two-tone approximations of vowel stimuli (/a/ and /u/). In the first experiment, the masking effect of F(1) on F(2) was evaluated by attenuating the level of F(1) relative to a fixed F(2) level. In the second experiment, the masking effect was evaluated by increasing the frequency separation between F(1) and F(2) using F(2) frequency as the variable. Results revealed that both attenuation of the F(1) level, and increasing the frequency separation between F(1) and F(2) increased the magnitude of the FFR component at F(2). These results are consistent with a release from off-frequency masking. Given that the results presented here are for high signal and masker levels and for relatively smaller frequency separation between the masker and the probe, it is possible that both suppression and excitatory spread contributed to the masking effects observed in our data. Copyright2009 S. Karger AG, Basel.

  9. Masking release due to linguistic and phonetic dissimilarity between the target and masker speech

    PubMed Central

    Calandruccio, Lauren; Brouwer, Susanne; Van Engen, Kristin J.; Dhar, Sumitrajit; Bradlow, Ann R.

    2013-01-01

    Purpose To investigate masking release for speech maskers for linguistically and phonetically close (English and Dutch) and distant (English and Mandarin) language pairs. Method Twenty monolingual speakers of English with normal-audiometric thresholds participated. Data are reported for an English sentence recognition task in English, Dutch and Mandarin competing speech maskers (Experiment I) and noise maskers (Experiment II) that were matched either to the long-term-average-speech spectra or to the temporal modulations of the speech maskers from Experiment I. Results Results indicated that listener performance increased as the target-to-masker linguistic distance increased (English-in-English < English-in-Dutch < English-in-Mandarin). Conclusions Spectral differences between maskers can account for some, but not all, of the variation in performance between maskers; however, temporal differences did not seem to play a significant role. PMID:23800811

  10. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and non-native speakers of English

    PubMed Central

    Calandruccio, Lauren; Bradlow, Ann R.; Dhar, Sumitrajit

    2013-01-01

    Background Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared to native-accented English speech was reported in Calandruccio, Dhar and Bradlow (2010). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. Purpose The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech affect masking release. Research Design A mixed model design with within- (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech, and high-intelligibility, moderate-intelligibility and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Study Sample Three listener groups were tested including monolingual English speakers with normal hearing, non-native speakers of English with normal hearing, and monolingual speakers of English with hearing loss. The non-native speakers of English were from various native-language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetrical, mild sloping to moderate sensorineural hearing loss. Data Collection and Analysis Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the keywords within the sentences (100 keywords/masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and the listener groups. Results Monolingual speakers of English with normal hearing benefited when the competing speech signal was foreign-accented compared to native-accented allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the non-native English listeners with normal hearing, nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Conclusions Slight modifications between the target and the masker speech allowed monolingual speakers of English with normal hearing to improve their recognition of native-accented English even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker, or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. PMID:25126683

  11. Bacterial cellulose skin masks-Properties and sensory tests.

    PubMed

    Pacheco, Guilherme; de Mello, Carolina Véspoli; Chiari-Andréo, Bruna Galdorfini; Isaac, Vera Lucia Borges; Ribeiro, Sidney José Lima; Pecoraro, Édison; Trovatti, Eliane

    2017-09-29

    Bacterial cellulose (BC) is a versatile material produced by microorganisms in the form of a membranous hydrogel, totally biocompatible, and endowed with high mechanical strength. Its high water-holding capacity based on its highly porous nanofibrillar structure allows BC to incorporate and to release substances very fast, thus being suitable for the preparation of skincare masks. The preparation and characterization of cosmetic masks based on BC membranes and active cosmetics. The masks were prepared by the simple incorporation of the cosmetic actives into BC membranes, used as a swelling matrix. The masks were characterized by Fourier transform infrared (FTIR), scanning electron microscopy (SEM), sensory tests, and skin moisture tests on volunteers. The results of sensory tests revealed the good performance of BC, being considered effective by the panel of volunteers, specially for adhesion to the skin (7.7 at the score scale), and improvement of the skin moisture (the hydration effect increased 76% in 75% of the volunteers that used vegetable extract mask formulation [VEM]), or a decrease in skin hydration (80% of the volunteers showed 32.6% decrease on skin hydration using propolis extract formulation [PEM] treatment), indicating the BC nanofiber membranes can be used to skincare applications. The results demonstrate the BC can be used as an alternative support for cosmetic actives for skin treatment. © 2017 Wiley Periodicals, Inc.

  12. Rapid modelling of the redshift-space power spectrum multipoles for a masked density field

    NASA Astrophysics Data System (ADS)

    Wilson, M. J.; Peacock, J. A.; Taylor, A. N.; de la Torre, S.

    2017-01-01

    In this work, we reformulate the forward modelling of the redshift-space power spectrum multipole moments for a masked density field, as encountered in galaxy redshift surveys. Exploiting the symmetries of the redshift-space correlation function, we provide a masked-field generalization of the Hankel transform relation between the multipole moments in real and Fourier space. Using this result, we detail how a likelihood analysis requiring computation for a broad range of desired P(k) models may be executed 103-104 times faster than with other common approaches, together with significant gains in spectral resolution. We present a concrete application to the complex angular geometry of the VIMOS Public Extragalactic Redshift Survey PDR-1 release and discuss the validity of this technique for finite-angle surveys.

  13. Propagation of resist heating mask error to wafer level

    NASA Astrophysics Data System (ADS)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.

  14. Social learning spreads knowledge about dangerous humans among American crows.

    PubMed

    Cornell, Heather N; Marzluff, John M; Pecoraro, Shannon

    2012-02-07

    Individuals face evolutionary trade-offs between the acquisition of costly but accurate information gained firsthand and the use of inexpensive but possibly less reliable social information. American crows (Corvus brachyrhynchos) use both sources of information to learn the facial features of a dangerous person. We exposed wild crows to a novel 'dangerous face' by wearing a unique mask as we trapped, banded and released 7-15 birds at five study sites near Seattle, WA, USA. An immediate scolding response to the dangerous mask after trapping by previously captured crows demonstrates individual learning, while an immediate response by crows that were not captured probably represents conditioning to the trapping scene by the mob of birds that assembled during the capture. Later recognition of dangerous masks by lone crows that were never captured is consistent with horizontal social learning. Independent scolding by young crows, whose parents had conditioned them to scold the dangerous mask, demonstrates vertical social learning. Crows that directly experienced trapping later discriminated among dangerous and neutral masks more precisely than did crows that learned through social means. Learning enabled scolding to double in frequency and spread at least 1.2 km from the place of origin over a 5 year period at one site.

  15. Application of the unified mask data format based on OASIS for VSB EB writers

    NASA Astrophysics Data System (ADS)

    Suzuki, Toshio; Hirumi, Junji; Suga, Osamu

    2005-11-01

    Mask data preparation (MDP) for modern mask manufacturing becomes a complex process because many kinds of EB data formats are used in mask makers and EB data files continue to become bigger by the application of RET. Therefore we developed a unified mask pattern data format named "OASIS.VSB1" and a job deck format named "MALY2" for Variable-Shaped-Beam (VSB) EB writers. OASIS.VSB is the mask pattern data format based on OASISTM 3 (Open Artwork System Interchange Standard) released as a successive format to GDSII by SEMI. We defined restrictions on OASIS for VSB EB writers to input OASIS.VSB data directly to VSB EB writers just like the native EB data. OASIS.VSB specification and MALY specification have been disclosed to the public and will become a SEMI standard in the near future. We started to promote the spread activities of OASIS.VSB and MALY. For practical use of OASIS.VSB and MALY, we are discussing the infrastructure system of MDP processing using OASIS.VSB and MALY with mask makers, VSB EB makers, and device makers. We are also discussing the tools for the infrastructure system with EDA vendors. The infrastructure system will enable TAT, the man-hour, and the cost in MDP to be reduced. In this paper, we propose the plan of the infrastructure system of MDP processing using OASIS.VSB and MALY as an application of OASIS.VSB and MALY.

  16. Listeners Experience Linguistic Masking Release in Noise-Vocoded Speech-in-Speech Recognition.

    PubMed

    Viswanathan, Navin; Kokkinakis, Kostas; Williams, Brittany T

    2018-02-15

    The purpose of this study was to evaluate whether listeners with normal hearing perceiving noise-vocoded speech-in-speech demonstrate better intelligibility of target speech when the background speech was mismatched in language (linguistic release from masking [LRM]) and/or location (spatial release from masking [SRM]) relative to the target. We also assessed whether the spectral resolution of the noise-vocoded stimuli affected the presence of LRM and SRM under these conditions. In Experiment 1, a mixed factorial design was used to simultaneously manipulate the masker language (within-subject, English vs. Dutch), the simulated masker location (within-subject, right, center, left), and the spectral resolution (between-subjects, 6 vs. 12 channels) of noise-vocoded target-masker combinations presented at +25 dB signal-to-noise ratio (SNR). In Experiment 2, the study was repeated using a spectral resolution of 12 channels at +15 dB SNR. In both experiments, listeners' intelligibility of noise-vocoded targets was better when the background masker was Dutch, demonstrating reliable LRM in all conditions. The pattern of results in Experiment 1 was not reliably different across the 6- and 12-channel noise-vocoded speech. Finally, a reliable spatial benefit (SRM) was detected only in the more challenging SNR condition (Experiment 2). The current study is the first to report a clear LRM benefit in noise-vocoded speech-in-speech recognition. Our results indicate that this benefit is available even under spectrally degraded conditions and that it may augment the benefit due to spatial separation of target speech and competing backgrounds.

  17. A new perspective on binaural integration using response time methodology: super capacity revealed in conditions of binaural masking release.

    PubMed

    Lentz, Jennifer J; He, Yuan; Townsend, James T

    2014-01-01

    This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time (RT) distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180° out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic vs. the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, RTs allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear vs. two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1), consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency)-most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy.

  18. A new perspective on binaural integration using response time methodology: super capacity revealed in conditions of binaural masking release

    PubMed Central

    Lentz, Jennifer J.; He, Yuan; Townsend, James T.

    2014-01-01

    This study applied reaction-time based methods to assess the workload capacity of binaural integration by comparing reaction time (RT) distributions for monaural and binaural tone-in-noise detection tasks. In the diotic contexts, an identical tone + noise stimulus was presented to each ear. In the dichotic contexts, an identical noise was presented to each ear, but the tone was presented to one of the ears 180° out of phase with respect to the other ear. Accuracy-based measurements have demonstrated a much lower signal detection threshold for the dichotic vs. the diotic conditions, but accuracy-based techniques do not allow for assessment of system dynamics or resource allocation across time. Further, RTs allow comparisons between these conditions at the same signal-to-noise ratio. Here, we apply a reaction-time based capacity coefficient, which provides an index of workload efficiency and quantifies the resource allocations for single ear vs. two ear presentations. We demonstrate that the release from masking generated by the addition of an identical stimulus to one ear is limited-to-unlimited capacity (efficiency typically less than 1), consistent with less gain than would be expected by probability summation. However, the dichotic presentation leads to a significant increase in workload capacity (increased efficiency)—most specifically at lower signal-to-noise ratios. These experimental results provide further evidence that configural processing plays a critical role in binaural masking release, and that these mechanisms may operate more strongly when the signal stimulus is difficult to detect, albeit still with nearly 100% accuracy. PMID:25202254

  19. DSCOVR EPIC L2 Atmospheric Correction (MAIAC) Data Release Announcement

    Atmospheric Science Data Center

    2018-06-22

    ... several atmospheric quantities including cloud mask and aerosol optical depth (AOD) required for atmospheric correction. The parameters ... is a useful complementary dataset to MODIS and VIIRS global aerosol products.   Information about the DSCOVR EPIC Atmospheric ...

  20. Bilateral Versus Unilateral Cochlear Implantation in Adult Listeners: Speech-On-Speech Masking and Multitalker Localization.

    PubMed

    Rana, Baljeet; Buchholz, Jörg M; Morgan, Catherine; Sharma, Mridula; Weller, Tobias; Konganda, Shivali Appaiah; Shirai, Kyoko; Kawano, Atsushi

    2017-01-01

    Binaural hearing helps normal-hearing listeners localize sound sources and understand speech in noise. However, it is not fully understood how far this is the case for bilateral cochlear implant (CI) users. To determine the potential benefits of bilateral over unilateral CIs, speech comprehension thresholds (SCTs) were measured in seven Japanese bilateral CI recipients using Helen test sentences (translated into Japanese) in a two-talker speech interferer presented from the front (co-located with the target speech), ipsilateral to the first-implanted ear (at +90° or -90°), and spatially symmetric at ±90°. Spatial release from masking was calculated as the difference between co-located and spatially separated SCTs. Localization was assessed in the horizontal plane by presenting either male or female speech or both simultaneously. All measurements were performed bilaterally and unilaterally (with the first implanted ear) inside a loudspeaker array. Both SCTs and spatial release from masking were improved with bilateral CIs, demonstrating mean bilateral benefits of 7.5 dB in spatially asymmetric and 3 dB in spatially symmetric speech mixture. Localization performance varied strongly between subjects but was clearly improved with bilateral over unilateral CIs with the mean localization error reduced by 27°. Surprisingly, adding a second talker had only a negligible effect on localization.

  1. In vitro and in vivo correlation of disintegration and bitter taste masking using orally disintegrating tablet containing ion exchange resin-drug complex.

    PubMed

    Kim, Jong-Il; Cho, Sang-Min; Cui, Jing-Hao; Cao, Qing-Ri; Oh, Euichaul; Lee, Beom-Jin

    2013-10-15

    Although the taste-masking of bitter drug using ion exchange resin has been recognized, in vitro testing using an electronic tongue (e-Tongue) and in vivo bitterness test by human panel test was not fully understood. In case of orally disintegrating tablet (ODT) containing bitter medicine, in vitro and in vivo disintegration is also importance for dosage performance. Donepezil hydrochloride was chosen as a model drug due to its bitterness and requires rapid disintegration for the preparation of ODT. In this study, ion exchange resin drug complex (IRDC) at three different ratios (1:2, 1:1, 2:1) was prepared using a spray-drying method and then IRDC-loaded ODT containing superdisintegrants (crospovidone, croscarmellose sodium, and sodium starch glycolate) were prepared by the direct compression method. The physical properties and morphologies were then characterized by scanning electron microscopy (SEM), X-ray powder diffraction (PXRD) and electrophoretic laser scattering (ELS), respectively. The in vitro taste-masking efficiency was measured with an electronic tongue (e-Tongue). In vivo bitterness scale was also evaluated by human volunteers and then we defined new term, "bitterness index (BI)" to link in vitro e-Tongue. There was a good correlation of IRDC between in vitro e-Tongue values and in vivo BI. Furthermore, IRDC-loaded ODT showed good in vitro/in vivo correlation in the disintegration time. The optimal IRDC-loaded ODTs displayed similar drug release profiles to the reference tablet (Aricept(®) ODT) in release media of pH 1.2, pH 4.0, pH 6.8 and distilled water but had significantly better palatability in vivo taste-masking evaluation. The current IRDC-loaded ODT according to the in vitro and in vivo correlation of disintegration and bitter taste masking could provide platforms in ODT dosage formulations of donepezil hydrochloride for improved patient compliances. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Electron beam mask writer EBM-9500 for logic 7nm node generation

    NASA Astrophysics Data System (ADS)

    Matsui, Hideki; Kamikubo, Takashi; Nakahashi, Satoshi; Nomura, Haruyuki; Nakayamada, Noriaki; Suganuma, Mizuna; Kato, Yasuo; Yashima, Jun; Katsap, Victor; Saito, Kenichi; Kobayashi, Ryoei; Miyamoto, Nobuo; Ogasawara, Munehiro

    2016-10-01

    Semiconductor scaling is slowing down because of difficulties of device manufacturing below logic 7nm node generation. Various lithography candidates which include ArF immersion with resolution enhancement technology (like Inversed Lithography technology), Extreme Ultra Violet lithography and Nano Imprint lithography are being developed to address the situation. In such advanced lithography, shot counts of mask patterns are estimated to increase explosively in critical layers, and then it is hoped that multi beam mask writer (MBMW) is released to handle them within realistic write time. However, ArF immersion technology with multiple patterning will continue to be a mainstream lithography solution for most of the layers. Then, the shot counts in less critical layers are estimated to be stable because of the limitation of resolution in ArF immersion technology. Therefore, single beam mask writer (SBMW) can play an important role for mask production still, relative to MBMW. Also the demand of SBMW seems actually strong for the logic 7nm node. To realize this, we have developed a new SBMW, EBM-9500 for mask fabrication in this generation. A newly introduced electron beam source enables higher current density of 1200A/cm2. Heating effect correction function has also been newly introduced to satisfy the requirements for both pattern accuracy and throughput. In this paper, we will report the configuration and performance of EBM-9500.

  3. A Cloud Mask for AIRS

    NASA Technical Reports Server (NTRS)

    Brubaker, N.; Jedlovec, G. J.

    2004-01-01

    With the preliminary release of AIRS Level 1 and 2 data to the scientific community, there is a growing need for an accurate AIRS cloud mask for data assimilation studies and in producing products derived from cloud free radiances. Current cloud information provided with the AIRS data are limited or based on simplified threshold tests. A multispectral cloud detection approach has been developed for AIRS that utilizes the hyper-spectral capabilities to detect clouds based on specific cloud signatures across the short wave and long wave infrared window regions. This new AIRS cloud mask has been validated against the existing AIRS Level 2 cloud product and cloud information derived from MODIS. Preliminary results for both day and night applications over the continental U.S. are encouraging. Details of the cloud detection approach and validation results will be presented at the conference.

  4. Social learning spreads knowledge about dangerous humans among American crows

    PubMed Central

    Cornell, Heather N.; Marzluff, John M.; Pecoraro, Shannon

    2012-01-01

    Individuals face evolutionary trade-offs between the acquisition of costly but accurate information gained firsthand and the use of inexpensive but possibly less reliable social information. American crows (Corvus brachyrhynchos) use both sources of information to learn the facial features of a dangerous person. We exposed wild crows to a novel ‘dangerous face’ by wearing a unique mask as we trapped, banded and released 7–15 birds at five study sites near Seattle, WA, USA. An immediate scolding response to the dangerous mask after trapping by previously captured crows demonstrates individual learning, while an immediate response by crows that were not captured probably represents conditioning to the trapping scene by the mob of birds that assembled during the capture. Later recognition of dangerous masks by lone crows that were never captured is consistent with horizontal social learning. Independent scolding by young crows, whose parents had conditioned them to scold the dangerous mask, demonstrates vertical social learning. Crows that directly experienced trapping later discriminated among dangerous and neutral masks more precisely than did crows that learned through social means. Learning enabled scolding to double in frequency and spread at least 1.2 km from the place of origin over a 5 year period at one site. PMID:21715408

  5. The Effects of Screw Configuration and Polymeric Carriers on Hot-Melt Extruded Taste-Masked Formulations Incorporated into Orally Disintegrating Tablets

    PubMed Central

    Morott, Joseph T.; Pimparade, Manjeet; Park, Jun-Bom; Worley, Chelsea P.; Majumdar, Soumyajit; Lian, Zhuoyang; Pinto, Elanor; Bi, Yunxia; Durig, Thomas; Repka, Michael A.

    2015-01-01

    The primary aim of this research was to produce successfully taste masked formulations of Sildenafil Citrate (SC) using hot-melt extrusion (HME) technology. Multiple screw configurations and polymeric carriers were evaluated for their effects on taste masking efficiency, which was assessed by both E-tongue analysis and in vitro dissolution in simulated salivary fluid (SSF, pH 6.8 artificial saliva). The screw configurations were further assessed for their effects on the morphology of the API using PXRD, FT-IR and mid-infrared chemical imaging. It was determined that the screw configuration had a profound effect on the taste masking efficiency of the formulations as a result of altering the physical state of the API. Selected extruded formulations using ethylcellulose (EC) with a pore former were further formulated into orally disintegrating tablets (ODTs), which were optimized by varying the grade and percentage of the superdisintegrant used. An optimized disintegration time of approximately 8 seconds was achieved. The final ODT formulation exhibited excellent taste masking properties with over 85% drug release in gastric media as well as physical tablet properties. Interestingly, friability, which tends to be a common concern when formulating ODTs, was well within the acceptable limits (<1%) for common tablets. PMID:25410968

  6. VizieR Online Data Catalog: KiDS-ESO-DR3 multi-band source catalog (de Jong+, 2017)

    NASA Astrophysics Data System (ADS)

    de Jong, J. T. A.; Verdoes Kleijn, G. A.; Erben, T.; Hildebrandt, H.; Kuijken, K.; Sikkema, G.; Brescia, M.; Bilicki, M.; Napolitano, N. R.; Amaro, V.; Begeman, K. G.; Boxhoorn, D. R.; Buddelmeijer, H.; Cavuoti, S.; Getman, F.; Grado, A.; Helmich, E.; Huang, Z.; Irisarri, N.; La Barbera, F.; Longo, G.; McFarland, J. P.; Nakajima, R.; Paolillo, M.; Puddu, E.; Radovich, M.; Rifatto, A.; Tortora, C; Valentijn, E. A.; Vellucci, C.; Vriend, W-J.; Amon, A.; Blake, C.; Choi, A.; Fenech, Conti I.; Herbonnet, R.; Heymans, C.; Hoekstra, H.; Klaes, D.; Merten, J.; Miller, L.; Schneider, P.; Viola, M.

    2017-04-01

    KiDS-ESO-DR3 contains a multi-band source catalogue encompassing all publicly released tiles, a total of 440 survey tiles including the coadded images, weight maps, masks and source lists of 292 survey tiles of KiDS-ESO-DR3, adding to the 148 tiles released previously (50 in KiDS-ESO-DR1 and 98 in KiDS-ESO-DR2). (1 data file).

  7. Binaural Hearing Ability With Bilateral Bone Conduction Stimulation in Subjects With Normal Hearing: Implications for Bone Conduction Hearing Aids.

    PubMed

    Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan

    The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.

  8. Preparation of sildenafil citrate microcapsules and in vitro/in vivo evaluation of taste masking efficiency.

    PubMed

    Yi, Eun-Jin; Kim, Ju-Young; Rhee, Yun-Seok; Kim, Su-Hyeon; Lee, Hyo-Joong; Park, Chun-Woong; Park, Eun-Seok

    2014-05-15

    The aim of the present study was to prepare the particulate taste-masking system to mask the bitter taste of sildenafil citrate (SC), a well-known phosphodiesterase-5 inhibitor used for erectile dysfunction (ED) and pulmonary artery hypertension (PAH). It was evaluated for the taste masking efficiency by the in vitro measurement using electronic tongue (e-tongue) system and the in vivo human panel sensory test. Microcapsules were prepared by microencapsulation with a gastro-soluble polymer, Eudragit(®) E100 (E100), using a spray drying technique at four different weight ratios (2:1, 1:1, 1:2, and 1:3). Characters of prepared microcapsules and the effect of polymer ratio on the taste masking were investigated. The particle morphology and the distribution of SC in microcapsules were observed by SEM-EDS and physical properties were evaluated by PXRD, Raman spectroscopy, and DSC. By drug dissolution studies at pH 1.2 buffer and DW, it was found that E100 was not able to alter the drug release in stomach. As the result of taste evaluation studies, there were a good correlation (R(2)=0.9867) between the weight ratio of polymer and the taste masking efficiency expressed in the distances on the PCA map of the e-tongue data, and a relevance of the e-tongue measurement with the result of sensory test. Copyright © 2014. Published by Elsevier B.V.

  9. Bilateral Versus Unilateral Cochlear Implantation in Adult Listeners: Speech-On-Speech Masking and Multitalker Localization

    PubMed Central

    Buchholz, Jörg M.; Morgan, Catherine; Sharma, Mridula; Weller, Tobias; Konganda, Shivali Appaiah; Shirai, Kyoko; Kawano, Atsushi

    2017-01-01

    Binaural hearing helps normal-hearing listeners localize sound sources and understand speech in noise. However, it is not fully understood how far this is the case for bilateral cochlear implant (CI) users. To determine the potential benefits of bilateral over unilateral CIs, speech comprehension thresholds (SCTs) were measured in seven Japanese bilateral CI recipients using Helen test sentences (translated into Japanese) in a two-talker speech interferer presented from the front (co-located with the target speech), ipsilateral to the first-implanted ear (at +90° or −90°), and spatially symmetric at ±90°. Spatial release from masking was calculated as the difference between co-located and spatially separated SCTs. Localization was assessed in the horizontal plane by presenting either male or female speech or both simultaneously. All measurements were performed bilaterally and unilaterally (with the first implanted ear) inside a loudspeaker array. Both SCTs and spatial release from masking were improved with bilateral CIs, demonstrating mean bilateral benefits of 7.5 dB in spatially asymmetric and 3 dB in spatially symmetric speech mixture. Localization performance varied strongly between subjects but was clearly improved with bilateral over unilateral CIs with the mean localization error reduced by 27°. Surprisingly, adding a second talker had only a negligible effect on localization. PMID:28752811

  10. pH- and ion-sensitive polymers for drug delivery

    PubMed Central

    Yoshida, Takayuki; Lai, Tsz Chung; Kwon, Glen S; Sako, Kazuhiro

    2013-01-01

    Introduction Drug delivery systems (DDSs) are important for effective, safe, and convenient administration of drugs. pH- and ion-responsive polymers have been widely employed in DDS for site-specific drug release due to their abilities to exploit specific pH- or ion-gradients in the human body. Areas covered Having pH-sensitivity, cationic polymers can mask the taste of drugs and release drugs in the stomach by responding to gastric low pH. Anionic polymers responsive to intestinal high pH are used for preventing gastric degradation of drug, colon drug delivery and achieving high bioavailability of weak basic drugs. Tumor-targeted DDSs have been developed based on polymers with imidazole groups or poly(β-amino ester) responsive to tumoral low pH. Polymers with pH-sensitive chemical linkages, such as hydrazone, acetal, ortho ester and vinyl ester, pH-sensitive cell-penetrating peptides and cationic polymers undergoing pH-dependent protonation have been studied to utilize the pH gradient along the endocytic pathway for intracellular drug delivery. As ion-sensitive polymers, ion-exchange resins are frequently used for taste-masking, counterion-responsive drug release and sustained drug release. Polymers responding to ions in the saliva and gastrointestinal fluids are also used for controlled drug release in oral drug formulations. Expert opinion Stimuli-responsive DDSs are important for achieving site-specific and controlled drug release; however, intraindividual, interindividual and intercellular variations of pH should be considered when designing DDSs or drug products. Combination of polymers and other components, and deeper understanding of human physiology are important for development of pH- and ion-sensitive polymeric DDS products for patients. PMID:23930949

  11. Transcriptomic changes during maize roots development responsive to Cadmium (Cd) pollution using comparative RNAseq-based approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, Hua; Sichuan Tourism College, Chengdu, 610000, Sichuan; He, Xiujing

    The heavy metal cadmium (Cd), acts as a widespread environmental contaminant, which has shown to adversely affect human health, food safety and ecosystem safety in recent years. However, research on how plant respond to various kinds of heavy metal stress is scarcely reported, especially for understanding of complex molecular regulatory mechanisms and elucidating the gene networks of plant respond to Cd stress. Here, transcriptomic changes during Mo17 and B73 seedlings development responsive to Cd pollution were investigated and comparative RNAseq-based approach in both genotypes were performed. 115 differential expression genes (DEGs) with significant alteration in expression were found co-modulated inmore » both genotypes during the maize seedling development; of those, most of DGEs were found comprised of stress and defense responses proteins, transporters, as well as transcription factors, such as thaumatin-like protein, ZmOPR2 and ZmOPR5. More interestingly, genotype-specific transcriptional factors changes induced by Cd stress were found contributed to the regulatory mechanism of Cd sensitivity in both different genotypes. Moreover, 12 co-expression modules associated with specific biological processes or pathways (M1 to M12) were identified by consensus co-expression network. These results will expand our understanding of complex molecular mechanism of response and defense to Cd exposure in maize seedling roots. - Highlights: • Transcriptomic changes responsive to Cd pollution using comparative RNAseq-based approach. • 115 differential expression genes (DEGs) were found co-modulated in both genotypes. • Most of DGEs belong to stress and defense responses proteins, transporters, transcription factors. • 12 co-expression modules associated with specific biological processes or pathways. • Genotype-specific transcriptional factors changes induced by Cd stress were found.« less

  12. Imaging of neural oscillations with embedded inferential and group prevalence statistics.

    PubMed

    Donhauser, Peter W; Florin, Esther; Baillet, Sylvain

    2018-02-01

    Magnetoencephalography and electroencephalography (MEG, EEG) are essential techniques for studying distributed signal dynamics in the human brain. In particular, the functional role of neural oscillations remains to be clarified. For that reason, imaging methods need to identify distinct brain regions that concurrently generate oscillatory activity, with adequate separation in space and time. Yet, spatial smearing and inhomogeneous signal-to-noise are challenging factors to source reconstruction from external sensor data. The detection of weak sources in the presence of stronger regional activity nearby is a typical complication of MEG/EEG source imaging. We propose a novel, hypothesis-driven source reconstruction approach to address these methodological challenges. The imaging with embedded statistics (iES) method is a subspace scanning technique that constrains the mapping problem to the actual experimental design. A major benefit is that, regardless of signal strength, the contributions from all oscillatory sources, which activity is consistent with the tested hypothesis, are equalized in the statistical maps produced. We present extensive evaluations of iES on group MEG data, for mapping 1) induced oscillations using experimental contrasts, 2) ongoing narrow-band oscillations in the resting-state, 3) co-modulation of brain-wide oscillatory power with a seed region, and 4) co-modulation of oscillatory power with peripheral signals (pupil dilation). Along the way, we demonstrate several advantages of iES over standard source imaging approaches. These include the detection of oscillatory coupling without rejection of zero-phase coupling, and detection of ongoing oscillations in deeper brain regions, where signal-to-noise conditions are unfavorable. We also show that iES provides a separate evaluation of oscillatory synchronization and desynchronization in experimental contrasts, which has important statistical advantages. The flexibility of iES allows it to be adjusted to many experimental questions in systems neuroscience.

  13. Imaging of neural oscillations with embedded inferential and group prevalence statistics

    PubMed Central

    2018-01-01

    Magnetoencephalography and electroencephalography (MEG, EEG) are essential techniques for studying distributed signal dynamics in the human brain. In particular, the functional role of neural oscillations remains to be clarified. For that reason, imaging methods need to identify distinct brain regions that concurrently generate oscillatory activity, with adequate separation in space and time. Yet, spatial smearing and inhomogeneous signal-to-noise are challenging factors to source reconstruction from external sensor data. The detection of weak sources in the presence of stronger regional activity nearby is a typical complication of MEG/EEG source imaging. We propose a novel, hypothesis-driven source reconstruction approach to address these methodological challenges. The imaging with embedded statistics (iES) method is a subspace scanning technique that constrains the mapping problem to the actual experimental design. A major benefit is that, regardless of signal strength, the contributions from all oscillatory sources, which activity is consistent with the tested hypothesis, are equalized in the statistical maps produced. We present extensive evaluations of iES on group MEG data, for mapping 1) induced oscillations using experimental contrasts, 2) ongoing narrow-band oscillations in the resting-state, 3) co-modulation of brain-wide oscillatory power with a seed region, and 4) co-modulation of oscillatory power with peripheral signals (pupil dilation). Along the way, we demonstrate several advantages of iES over standard source imaging approaches. These include the detection of oscillatory coupling without rejection of zero-phase coupling, and detection of ongoing oscillations in deeper brain regions, where signal-to-noise conditions are unfavorable. We also show that iES provides a separate evaluation of oscillatory synchronization and desynchronization in experimental contrasts, which has important statistical advantages. The flexibility of iES allows it to be adjusted to many experimental questions in systems neuroscience. PMID:29408902

  14. Optimization of a novel wax matrix system using aminoalkyl methacrylate copolymer E and ethylcellulose to suppress the bitter taste of acetaminophen.

    PubMed

    Shiino, Kai; Iwao, Yasunori; Miyagishima, Atsuo; Itai, Shigeru

    2010-08-16

    The purpose of the present study was to design and evaluate a novel wax matrix system containing various ratios of aminoalkyl methacrylate copolymer E (AMCE) and ethylcellulose (EC) as functional polymers in order to achieve the optimal acetaminophen (APAP) release rate for taste masking. A two factor, three level (3(2)) full factorial study design was used to optimize the ratios of AMCE and EC, and the release of APAP from the wax matrix was evaluated using a stationary disk in accordance with the paddle method. The disk was prepared by congealing glyceryl monostearate (GM), a wax with a low melting point, with various ratios of polymers and APAP. The criteria for release rate of APAP from the disk at pH 4.0 and pH 6.5 were calculated to be more than 0.5017 microg/(mlxmin) and less than 0.1414 microg/(mlxmin), respectively, under the assumption that the particle size of spherical matrix should be 100 microm. In multiple regression analysis, the release of APAP at pH 4.0 was found to increase markedly as the concentration of AMCE increased, whereas the release of APAP at pH 6.5 decreased as the EC concentration increased, even when a high level of AMCE was incorporated. Using principle component analysis, it was found that the viscosity of the matrix affects the pH-dependent release of APAP at pH 4.0 and pH 6.5. Furthermore, using multiple regression analysis, the optimum ratio of APAP:AMCE:EC:GM was found to be 30:7:10:53, and the release pattern of APAP from the optimum wax formulation nearly complied with the desired criteria. Therefore, the present study demonstrated that the incorporation of AMCE and EC into a wax matrix system enabled the appropriate release of APAP as a means of taste masking. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  15. Pharmaceutical Applications of Ion-Exchange Resins

    ERIC Educational Resources Information Center

    Elder, David

    2005-01-01

    The historical uses of ion-exchanged resins and a summary of the basic chemical principles involved in the ion-exchanged process are discussed. Specific applications of ion-exchange are provided that include drug stabilization, pharmaceutical excipients, taste-masking agents, oral sustained-release products, topical products for local application…

  16. Fast releasing oral electrospun PVP/CD nanofiber mats of taste-masked meloxicam.

    PubMed

    Samprasit, Wipada; Akkaramongkolporn, Prasert; Ngawhirunpat, Tanasait; Rojanarata, Theerasak; Kaomongkolgit, Ruchadaporn; Opanasopit, Praneet

    2015-06-20

    Fast release and taste masking of meloxicam (MX)-loaded polyvinylpyrrolidone (PVP)/cyclodextrin (CD) nanofiber mats were developed using an electrospinning process. CDs were blended to improve the stability of the mats. The morphology and diameter of the mats were determined using scanning electron microscopy (SEM); physical and mechanical properties were also studied. The MX content, disintegration time, MX release and cytotoxicity of the mats were investigated. In vivo studies were also performed in healthy human volunteers. The results indicated that the mats were successfully prepared with fiber in the nanometer range. MX was well incorporated into the mats, with an amorphous form. The mats showed suitable tensile strength. CDs improved the physical stability by their cage-like supramolecular structure to protect from humidity and moisture, and create bead free nanofiber mats. The nanofiber mats with CDs were physically stable without any hygroscopicity and fusion. A fast disintegration and release of MX was achieved. Moreover, this mat released MX faster than the MX powder and commercial tablets. The cytotoxicity test revealed that mats were safe for a 5-min incubation. The disintegration studies indicated that in vivo disintegration agreed with the in vitro studies; the mat rapidly disintegrated in the mouth. The less bitter of MX was occurred in the mats that incorporated CD, menthol and aspartame. In addition, this mat was physical stable for 6 months. The results suggest that these mats may be a good candidate for fast dissolving drug delivery systems of bitter drugs to increase the palatability of dosage forms. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. In-vitro and in-vivo evaluation of taste-masked cetirizine hydrochloride formulated in oral lyophilisates.

    PubMed

    Preis, Maren; Grother, Leon; Axe, Philip; Breitkreutz, Jörg

    2015-08-01

    The use of solid oral dosage forms is typically favored with regard to stability and ease of administration. The aim of this study was to investigate whether cyclodextrins (CD) or ion exchange resins (IER) could be used to taste-mask cetirizine HCl when formulated in a freeze-dried oral formulation. The oral lyophilisates were produced using the Zydis(®) technology that offer the opportunity to produce the dosage form directly in the aluminum laminate blister packs. This study confirmed that a pre-formed resinate of cetirizine HCl and various cyclodextrins can be successfully incorporated into the Zydis(®) oral lyophilisate. A chemically stable product with acceptable release profile was obtained in the case of cyclodextrin. This study has also demonstrated that the Insent(®) taste sensing system is a useful technique for predicting the taste-masking potential of Zydis(®) formulations. The electronic taste sensing system (e-tongue) data can be used to provide guidance on the selection of taste-masked formulations. Principal component analysis (PCA) of sensor data by plotting the PCA scores revealed the effects of used taste-masking techniques on the e-tongue sensors, indicating the successful taste improvement. The PCA plot of the taste sensor data revealed larger distances between the non-taste-masked sample and the CD- and IER-loaded samples, and the shift toward the drug-free formulations and excipient signals indicates a modification of the product taste. The human taste trial confirms the acceptability of the selected promising formulations. The taste evaluation results showed that an effectively taste-masked formulation has been achieved using β-cyclodextrin and cherry/sucralose flavor system with over 80% of volunteers finding the tablet to be acceptable. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. β-Glucans Are Masked but Contribute to Pulmonary Inflammation During Pneumocystis Pneumonia

    PubMed Central

    Kutty, Geetha; Davis, A. Sally; Ferreyra, Gabriela A.; Qiu, Ju; Huang, Da Wei; Sassi, Monica; Bishop, Lisa; Handley, Grace; Sherman, Brad; Lempicki, Richard; Kovacs, Joseph A.

    2016-01-01

    β-glucans, which can activate innate immune responses, are a major component in the cell wall of the cyst form of Pneumocystis. In the current study, we examined whether β-1,3-glucans are masked by surface proteins in Pneumocystis and what role β-glucans play in Pneumocystis-associated inflammation. For 3 species, including Pneumocystis jirovecii, which causes Pneumocystis pneumonia in humans, Pneumocystis carinii, and Pneumocystis murina, β-1,3-glucans were masked in most organisms, as demonstrated by increased exposure following trypsin treatment. Using quantitative polymerase chain reaction and microarray techniques, we demonstrated in a mouse model of Pneumocystis pneumonia that treatment with caspofungin, an inhibitor of β-1,3-glucan synthesis, for 21 days decreased expression of a broad panel of inflammatory markers, including interferon γ, tumor necrosis factor α, interleukin 1β, interleukin 6, and multiple chemokines/chemokine ligands. Thus, β-glucans in Pneumocystis cysts are largely masked, which likely decreases innate immune activation; this mechanism presumably was developed for interactions with immunocompetent hosts, in whom organism loads are substantially lower. In immunosuppressed hosts with a high organism burden, organism death and release of glucans appears to be an important contributor to deleterious host inflammatory responses. PMID:27324243

  19. Rapid and tunable method to temporally control gene editing based on conditional Cas9 stabilization. | Office of Cancer Genomics

    Cancer.gov

    The CRISPR/Cas9 system is a powerful tool for studying gene function. Here, we describe a method that allows temporal control of CRISPR/Cas9 activity based on conditional Cas9 destabilization. We demonstrate that fusing an FKBP12-derived destabilizing domain to Cas9 (DD-Cas9) enables conditional Cas9 expression and temporal control of gene editing in the presence of an FKBP12 synthetic ligand. This system can be easily adapted to co-express, from the same promoter, DD-Cas9 with any other gene of interest without co-modulation of the latter.

  20. Low-noise delays from dynamic Brillouin gratings based on perfect Golomb coding of pump waves.

    PubMed

    Antman, Yair; Levanon, Nadav; Zadok, Avi

    2012-12-15

    A method for long variable all-optical delay is proposed and simulated, based on reflections from localized and stationary dynamic Brillouin gratings (DBGs). Inspired by radar methods, the DBGs are inscribed by two pumps that are comodulated by perfect Golomb codes, which reduce the off-peak reflectivity. Compared with random bit sequence coding, Golomb codes improve the optical signal-to-noise ratio (OSNR) of delayed waveforms by an order of magnitude. Simulations suggest a delay of 5  Gb/s data by 9 ns, or 45 bit durations, with an OSNR of 13 dB.

  1. Lean production of taste improved lipidic sodium benzoate formulations.

    PubMed

    Eckert, C; Pein, M; Breitkreutz, J

    2014-10-01

    Sodium benzoate is a highly soluble orphan drug with unpleasant taste and high daily dose. The aim of this study was to develop a child appropriate, individually dosable, and taste masked dosage form utilizing lipids in melt granulation process and tableting. A saliva resistant coated lipid granule produced by extrusion served as reference product. Low melting hard fat was found to be appropriate as lipid binder in high-shear granulation. The resulting granules were compressed to minitablets without addition of other excipients. Compression to 2mm minitablets decreased the dissolved API amount within the first 2 min of dissolution from 33% to 23%. The Euclidean distances, calculated from electronic tongue measurements, were reduced, indicating an improved taste. The reference product showed a lag time in dissolution, which is desirable for taste masking. Although a lag time was not achieved for the lipidic minitablets, drug release in various food materials was reduced to 2%, assuming a suitable taste masking for oral sodium benzoate administration. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Atomic Ferris wheel beams

    NASA Astrophysics Data System (ADS)

    Lembessis, Vasileios E.

    2017-07-01

    We study the generation of atom vortex beams in the case where a Bose-Einstein condensate, released from a trap and moving in free space, is diffracted from a properly tailored light mask with a spiral transverse profile. We show how such a diffraction scheme could lead to the production of an atomic Ferris wheel beam.

  3. Peptidase modulation of airway effects of neuropeptides.

    PubMed

    Lilly, C M; Drazen, J M; Shore, S A

    1993-09-01

    SP and NKA are potent endogenous bronchoconstrictors, whereas VIP is a potent endogenous bronchodilator. There is abundant evidence that these neuropeptides are released in the lung in a variety of conditions and that they have the capacity to modulate the bronchoactivity of the same stimuli that release them. On many occasions, their bronchoactive effects are masked by their degradation at or near the site of their release. However, when the microenvironment is modified to decrease their cleavage, they can express enhanced physiologic effects. Although it appears that the human asthmatic lung may be an environment in which the effects of neuropeptides can be amplified, the role of neuropeptides in the pathogenesis of airway obstruction remains speculative.

  4. Orodispersible tablets containing taste-masked solid lipid pellets with metformin hydrochloride: Influence of process parameters on tablet properties.

    PubMed

    Petrovick, Gustavo Freire; Kleinebudde, Peter; Breitkreutz, Jörg

    2018-01-01

    Compaction of multiparticulates into tablets, particularly into orodispersible tablets (ODTs), is challenging. The compression of pellets, made by solid lipid extrusion/spheronization processes, presents peculiar difficulties since solid lipids usually soften or melt at relatively low temperature ranges and due to applied mechanical forces. Until now, there are no reports in literature about the development of ODTs based on solid lipid pellets. To investigate the feasibility of producing such tablets, a design of experiment (DoE) approach was performed to elucidate the influence of compression force and amount of two co-processed excipients (Ludiflash ® and Parteck ® ODT) on properties of the tablets (friability, tensile strength, and disintegration time). ODTs (15 mm, flat-faced) with solid lipid pellets (250-1000 µm in diameter) containing 500 mg of metformin HCl, presenting immediate drug release profile and taste-masked properties, were targeted. During compression, a strong lamination of the tablets containing Parteck ® ODT was observed. This phenomenon was prominently observed when high compression forces (≥5 kN) and high excipient amounts (≥40%; w/w) were used. On the other hand, the DoE focused on tablets with Ludiflash ® showed better results regarding the production of ODTs. A positive influence of the compression force on the tensile strength and disintegration time of the tablets, regarding specifications of the Ph. Eur., was observed. The increase in the amount of this excipient resulted in fast disintegrating tablets, however, a negative influence on the tensile strength was noticed. After optimization of the parameters and formulation, based on the DoE results and considering the Ph. Eur. specifications for tablets, ODTs based on lipid pellets containing metformin HCl presenting immediate release profile (85% drug release in less than 30 min) and taste-masked properties (determined by an electronic tongue) were successfully obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Binaural Speech Understanding With Bilateral Cochlear Implants in Reverberation.

    PubMed

    Kokkinakis, Kostas

    2018-03-08

    The purpose of this study was to investigate whether bilateral cochlear implant (CI) listeners who are fitted with clinical processors are able to benefit from binaural advantages under reverberant conditions. Another aim of this contribution was to determine whether the magnitude of each binaural advantage observed inside a highly reverberant environment differs significantly from the magnitude measured in a near-anechoic environment. Ten adults with postlingual deafness who are bilateral CI users fitted with either Nucleus 5 or Nucleus 6 clinical sound processors (Cochlear Corporation) participated in this study. Speech reception thresholds were measured in sound field and 2 different reverberation conditions (0.06 and 0.6 s) as a function of the listening condition (left, right, both) and the noise spatial location (left, front, right). The presence of the binaural effects of head-shadow, squelch, summation, and spatial release from masking in the 2 different reverberation conditions tested was determined using nonparametric statistical analysis. In the bilateral population tested, when the ambient reverberation time was equal to 0.6 s, results indicated strong positive effects of head-shadow and a weaker spatial release from masking advantage, whereas binaural squelch and summation contributed no statistically significant benefit to bilateral performance under this acoustic condition. These findings are consistent with those of previous studies, which have demonstrated that head-shadow yields the most pronounced advantage in noise. The finding that spatial release from masking produced little to almost no benefit in bilateral listeners is consistent with the hypothesis that additive reverberation degrades spatial cues and negatively affects binaural performance. The magnitude of 4 different binaural advantages was measured on the same group of bilateral CI subjects fitted with clinical processors in 2 different reverberation conditions. The results of this work demonstrate the impeding properties of reverberation on binaural speech understanding. In addition, results indicate that CI recipients who struggle in everyday listening environments are also more likely to benefit less in highly reverberant environments from their bilateral processors.

  6. An investigation into the mechanisms of drug release from taste-masking fatty acid microspheres.

    PubMed

    Qi, Sheng; Deutsch, David; Craig, Duncan Q M

    2008-09-01

    Fatty acid microspheres based on stearic and palmitic acids are known to form effective taste masking systems, although the mechanisms by which the drug is preferentially released in the lower gastrointestinal tract are not known. The objective of the present study was to identify the mechanisms involved, with a particular view to clarify the role of acid soap formation in the dissolution process. Microspheres were prepared by a spray chilling process. Using benzoic acid as a model drug and an alkaline dissolution medium, a faster drug release was observed in the mixed fatty acid formulation (50:50 stearic:palmitic acid (w/w)) compared to the single fatty acid component systems. Thermal and powder X-ray diffraction studies indicated a greater degree of acid soap formation for the mixed formulation in alkaline media compared to the single fatty acid systems. Particle size and porosity studies indicated a modest reduction in size for the mixed systems and an increase in porosity on immersion in the dissolution medium. It is proposed that the mixed fatty acid system form a mixed crystal system which in turn facilitates interaction with the dissolution medium, thereby leading to a greater propensity for acid soap formation which in turn forms a permeable liquid crystalline phase through which the drug may diffuse. The role of dissolution of palmitic acid into the dissolution medium is also discussed as a secondary mechanism.

  7. Linguistic contributions to speech-on-speech masking for native and non-native listeners: language familiarity and semantic content.

    PubMed

    Brouwer, Susanne; Van Engen, Kristin J; Calandruccio, Lauren; Bradlow, Ann R

    2012-02-01

    This study examined whether speech-on-speech masking is sensitive to variation in the degree of similarity between the target and the masker speech. Three experiments investigated whether speech-in-speech recognition varies across different background speech languages (English vs Dutch) for both English and Dutch targets, as well as across variation in the semantic content of the background speech (meaningful vs semantically anomalous sentences), and across variation in listener status vis-à-vis the target and masker languages (native, non-native, or unfamiliar). The results showed that the more similar the target speech is to the masker speech (e.g., same vs different language, same vs different levels of semantic content), the greater the interference on speech recognition accuracy. Moreover, the listener's knowledge of the target and the background language modulate the size of the release from masking. These factors had an especially strong effect on masking effectiveness in highly unfavorable listening conditions. Overall this research provided evidence that that the degree of target-masker similarity plays a significant role in speech-in-speech recognition. The results also give insight into how listeners assign their resources differently depending on whether they are listening to their first or second language. © 2012 Acoustical Society of America

  8. Linguistic contributions to speech-on-speech masking for native and non-native listeners: Language familiarity and semantic content

    PubMed Central

    Brouwer, Susanne; Van Engen, Kristin J.; Calandruccio, Lauren; Bradlow, Ann R.

    2012-01-01

    This study examined whether speech-on-speech masking is sensitive to variation in the degree of similarity between the target and the masker speech. Three experiments investigated whether speech-in-speech recognition varies across different background speech languages (English vs Dutch) for both English and Dutch targets, as well as across variation in the semantic content of the background speech (meaningful vs semantically anomalous sentences), and across variation in listener status vis-à-vis the target and masker languages (native, non-native, or unfamiliar). The results showed that the more similar the target speech is to the masker speech (e.g., same vs different language, same vs different levels of semantic content), the greater the interference on speech recognition accuracy. Moreover, the listener’s knowledge of the target and the background language modulate the size of the release from masking. These factors had an especially strong effect on masking effectiveness in highly unfavorable listening conditions. Overall this research provided evidence that that the degree of target-masker similarity plays a significant role in speech-in-speech recognition. The results also give insight into how listeners assign their resources differently depending on whether they are listening to their first or second language. PMID:22352516

  9. On Fock-space representations of quantized enveloping algebras related to noncommutative differential geometry

    NASA Astrophysics Data System (ADS)

    Jurčo, B.; Schlieker, M.

    1995-07-01

    In this paper explicitly natural (from the geometrical point of view) Fock-space representations (contragradient Verma modules) of the quantized enveloping algebras are constructed. In order to do so, one starts from the Gauss decomposition of the quantum group and introduces the differential operators on the corresponding q-deformed flag manifold (assumed as a left comodule for the quantum group) by a projection to it of the right action of the quantized enveloping algebra on the quantum group. Finally, the representatives of the elements of the quantized enveloping algebra corresponding to the left-invariant vector fields on the quantum group are expressed as first-order differential operators on the q-deformed flag manifold.

  10. Transient Auditory Storage of Acoustic Details Is Associated with Release of Speech from Informational Masking in Reverberant Conditions

    ERIC Educational Resources Information Center

    Huang, Ying; Huang, Qiang; Chen, Xun; Wu, Xihong; Li, Liang

    2009-01-01

    Perceptual integration of the sound directly emanating from the source with reflections needs both temporal storage and correlation computation of acoustic details. We examined whether the temporal storage is frequency dependent and associated with speech unmasking. In Experiment 1, a break in correlation (BIC) between interaurally correlated…

  11. Spatial Release From Masking in 2-Year-Olds With Normal Hearing and With Bilateral Cochlear Implants

    PubMed Central

    Hess, Christi L.; Misurelli, Sara M.; Litovsky, Ruth Y.

    2018-01-01

    This study evaluated spatial release from masking (SRM) in 2- to 3-year-old children who are deaf and were implanted with bilateral cochlear implants (BiCIs), and in age-matched normal-hearing (NH) toddlers. Here, we examined whether early activation of bilateral hearing has the potential to promote SRM that is similar to age-matched NH children. Listeners were 13 NH toddlers and 13 toddlers with BiCIs, ages 27 to 36 months. Speech reception thresholds (SRTs) were measured for target speech in front (0°) and for competitors that were either Colocated in front (0°) or Separated toward the right (+90°). SRM was computed as the difference between SRTs in the front versus in the asymmetrical condition. Results show that SRTs were higher in the BiCI than NH group in all conditions. Both groups had higher SRTs in the Colocated and Separated conditions compared with Quiet, indicating masking. SRM was significant only in the NH group. In the BiCI group, the group effect of SRM was not significant, likely limited by the small sample size; however, all but two children had SRM values within the NH range. This work shows that to some extent, the ability to use spatial cues for source segregation develops by age 2 to 3 in NH children and is attainable in most of the children in the BiCI group. There is potential for the paradigm used here to be used in clinical settings to evaluate outcomes of bilateral hearing in very young children. PMID:29761735

  12. Novel levocetirizine HCl tablets with enhanced palatability: synergistic effect of combining taste modifiers and effervescence technique

    PubMed Central

    Labib, Gihan S

    2015-01-01

    Objectives Levocetirizine HCl, a second-generation piperazine derivative and H1-selective antihistaminic agent, possesses few side effects. The first objective of the study was to compare and evaluate the taste-masking effect of different ratios of 2-hydroxypropyl-β-cyclodextrin and mannitol on levocetirizine HCl using an inclusion complex and solid dispersion, respectively. The second objective was to study the possibility of preparing and evaluating effervescent tablets from the best-chosen taste-masked blends for the purpose of their use either as orodispersible tablets or as water-soluble effervescent tablets, according to patients’ will. Materials and methods Prepared taste-masked blends were prepared and subjected to palatability, Fourier-transform infrared spectroscopy, and differential scanning calorimetry studies. Tablets containing different percentages of effervescent mixtures were prepared by direct compression on the selected taste-modified blends. Evaluation tests were conducted, including flowability and compressibility on the precompressed blends and hardness, friability, wetting time, effervescent time, in vitro, in vivo disintegration time, and in vitro dissolution study on the compressed tablets. Formulated tablets were evaluated and compared to marketed orodispersible tablets for mouth feel and palatability. Results All prepared tablets showed convenient physical and palatability properties compared to the selected brand. The in vitro drug-release study revealed fast release of levocetirizine HCl within 5 minutes from all prepared tablets. Conclusion Levocetirizine HCl effervescent tablets are likely to increase patient compliance with drug administration. Moreover, the use of these effervescent tablets in an orodispersible dosage form can improve oral drug bioavailability and act as an attractive pediatric dosage form. PMID:26379426

  13. Development and Performance Evaluation of an Exhaled-Breath Bioaerosol Collector for Influenza Virus

    PubMed Central

    McDevitt, James J.; Koutrakis, Petros; Ferguson, Stephen T.; Wolfson, Jack M.; Fabian, M. Patricia; Martins, Marco; Pantelic, Jovan; Milton, Donald K.

    2013-01-01

    The importance of the aerosol mode for transmission of influenza is unknown. Understanding the role of aerosols is essential to developing public health interventions such as the use of surgical masks as a source control to prevent the release of infectious aerosols. Little information is available on the number and size of particles generated by infected persons, which is partly due to the limitations of conventional air samplers, which do not efficiently capture fine particles or maintain microorganism viability. We designed and built a new sampler, called the G-II, that collects exhaled breath particles that can be used in infectivity analyses. The G-II allows test subjects to perform various respiratory maneuvers (i.e. tidal breathing, coughing, and talking) and allows subjects to wear a mask or respirator during testing. A conventional slit impactor collects particles > 5.0 μm. Condensation of water vapor is used to grow remaining particles, including fine particles, to a size large enough to be efficiently collected by a 1.0 μm slit impactor and be deposited into a buffer-containing collector. We evaluated the G-II for fine particle collection efficiency with inert particle aerosols and evaluated infective virus collection using influenza A virus aerosols. Testing results showed greater than 85% collection efficiency for particles greater than 50nm and influenza virus collection comparable with a reference SKC BioSampler®. The new design will enable determination of exhaled infectious virus generation rate and evaluate control strategies such as wearing a surgical type mask to prevent the release of viruses from infected persons. PMID:23418400

  14. Formulation and evaluation of microsphere based oro dispersible tablets of itopride hcl

    PubMed Central

    2012-01-01

    Background The purpose of the present work is to mask the intensely bitter taste of Itopride HCl and to formulate an Oro dispersible tablet (ODT) of the taste-masked drug by incorporation of microspheres in the tablets for use in specific populations viz. pediatrics, geriatrics and patients experiencing difficulty in swallowing. Methods With this objective in mind, microspheres loaded with Itopride HCl were prepared by solvent evaporation method using acetone as solvent for pH-sensitive polymer, Eudragit EPO and light liquid paraffin as the encapsulating medium. The prepared microspheres were characterized with regard to yield, drug content, flow properties, particle size and size distribution, surface features, in vitro drug release and taste. The ODTs so prepared from these microspheres were evaluated for hardness, thickness, weight variation, friability, disintegration time, drug content, wetting time, water absorption ratio, moisture uptake, in vitro dispersion, in vitro disintegration, in vitro drug release and stability. Results The average size of microspheres was found to be satisfactory in terms of the size and size distribution. Microspheres prepared were of a regular spherical shape. Comparison of the dissolution profiles of microspheres in different pH media showed that microspheres having drug: polymer ratio of 1:2 produced a retarding effect in simulated salivary fluid (pH 6.8) and were further used for formulation into ODTs after addition of suitable amounts of excipients such as superdisintegrant, diluent, sweetener and flavor of directly compressible grade. Conclusions Effective taste-masking was achieved for Itopride HCl by way of preparation of microspheres and ODTs of acceptable characteristics. PMID:23351176

  15. Formulation and evaluation of microsphere based oro dispersible tablets of itopride hcl.

    PubMed

    Shah, Sanjay; Madan, Sarika; Agrawal, Ss

    2012-09-03

    The purpose of the present work is to mask the intensely bitter taste of Itopride HCl and to formulate an Oro dispersible tablet (ODT) of the taste-masked drug by incorporation of microspheres in the tablets for use in specific populations viz. pediatrics, geriatrics and patients experiencing difficulty in swallowing. With this objective in mind, microspheres loaded with Itopride HCl were prepared by solvent evaporation method using acetone as solvent for pH-sensitive polymer, Eudragit EPO and light liquid paraffin as the encapsulating medium. The prepared microspheres were characterized with regard to yield, drug content, flow properties, particle size and size distribution, surface features, in vitro drug release and taste. The ODTs so prepared from these microspheres were evaluated for hardness, thickness, weight variation, friability, disintegration time, drug content, wetting time, water absorption ratio, moisture uptake, in vitro dispersion, in vitro disintegration, in vitro drug release and stability. The average size of microspheres was found to be satisfactory in terms of the size and size distribution. Microspheres prepared were of a regular spherical shape. Comparison of the dissolution profiles of microspheres in different pH media showed that microspheres having drug: polymer ratio of 1:2 produced a retarding effect in simulated salivary fluid (pH 6.8) and were further used for formulation into ODTs after addition of suitable amounts of excipients such as superdisintegrant, diluent, sweetener and flavor of directly compressible grade. Effective taste-masking was achieved for Itopride HCl by way of preparation of microspheres and ODTs of acceptable characteristics.

  16. A frequency and pulse-width co-modulation strategy for transcutaneous neuromuscular electrical stimulation based on sEMG time-domain features

    NASA Astrophysics Data System (ADS)

    Zhou, Yu-Xuan; Wang, Hai-Peng; Bao, Xue-Liang; Lü, Xiao-Ying; Wang, Zhi-Gong

    2016-02-01

    Objective. Surface electromyography (sEMG) is often used as a control signal in neuromuscular electrical stimulation (NMES) systems to enhance the voluntary control and proprioceptive sensory feedback of paralyzed patients. Most sEMG-controlled NMES systems use the envelope of the sEMG signal to modulate the stimulation intensity (current amplitude or pulse width) with a constant frequency. The aims of this study were to develop a strategy that co-modulates frequency and pulse width based on features of the sEMG signal and to investigate the torque-reproduction performance and the level of fatigue resistance achieved with our strategy. Approach. We examined the relationships between wrist torque and two stimulation parameters (frequency and pulse width) and between wrist torque and two sEMG time-domain features (mean absolute value (MAV) and number of slope sign changes (NSS)) in eight healthy volunteers. By using wrist torque as an intermediate variable, customized and generalized transfer functions were constructed to convert the two features of the sEMG signal into the two stimulation parameters, thereby establishing a MAV/NSS dual-coding (MNDC) algorithm. Wrist torque reproduction performance was assessed by comparing the torque generated by the algorithms with that originally recorded during voluntary contractions. Muscle fatigue was assessed by measuring the decline percentage of the peak torque and by comparing the torque time integral of the response to test stimulation trains before and after fatigue sessions. Main Results. The MNDC approach could produce a wrist torque that closely matched the voluntary wrist torque. In addition, a smaller decay in the wrist torque was observed after the MNDC-coded fatigue stimulation was applied than after stimulation using pulse-width modulation alone. Significance. Compared with pulse-width modulation stimulation strategies that are based on sEMG detection, the MNDC strategy is more effective for both voluntary muscle force reproduction and muscle fatigue reduction.

  17. Comodulation of dopamine and serotonin on prefrontal cortical rhythms: a theoretical study

    PubMed Central

    Wang, Da-Hui; Wong-Lin, KongFatt

    2013-01-01

    The prefrontal cortex (PFC) is implicated to play an important role in cognitive control. Abnormal PFC activities and rhythms have been observed in some neurological and neuropsychiatric disorders, and evidences suggest influences from the neuromodulators dopamine (DA) and serotonin (5-HT). Despite the high level of interest in these brain systems, the combined effects of DA and 5-HT modulation on PFC dynamics remain unknown. In this work, we build a mathematical model that incorporates available experimental findings to systematically study the comodulation of DA and 5-HT on the network behavior, focusing on beta and gamma band oscillations. Single neuronal model shows pyramidal cells with 5-HT1A and 2A receptors can be non-monotonically modulated by 5-HT. Two-population excitatory-inhibitory type network consisting of pyramidal cells with D1 receptors can provide rich repertoires of oscillatory behavior. In particular, 5-HT and DA can modulate the amplitude and frequency of the oscillations, which can emerge or cease, depending on receptor types. Certain receptor combinations are conducive for the robustness of the oscillatory regime, or the existence of multiple discrete oscillatory regimes. In a multi-population heterogeneous model that takes into account possible combination of receptors, we demonstrate that robust network oscillations require high DA concentration. We also show that selective D1 receptor antagonists (agonists) tend to suppress (enhance) network oscillations, increase the frequency from beta toward gamma band, while selective 5-HT1A antagonists (agonists) act in opposite ways. Selective D2 or 5-HT2A receptor antagonists (agonists) can lead to decrease (increase) in oscillation amplitude, but only 5-HT2A antagonists (agonists) can increase (decrease) the frequency. These results are comparable to some pharmacological effects. Our work illustrates the complex mechanisms of DA and 5-HT when operating simultaneously through multiple receptors. PMID:23935568

  18. Noggin and BMP4 co-modulate adult hippocampal neurogenesis in the APP{sub swe}/PS1{sub {Delta}E9} transgenic mouse model of Alzheimer's disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Jun; Department of Physiology, Third Military Medical University, Chongqing 400038; Song, Min

    2009-07-31

    In addition to the subventricular zone, the dentate gyrus of the hippocampus is one of the few brain regions in which neurogenesis continues into adulthood. Perturbation of neurogenesis can alter hippocampal function, and previous studies have shown that neurogenesis is dysregulated in Alzheimer disease (AD) brain. Bone morphogenetic protein-4 (BMP4) and its antagonist Noggin have been shown to play important roles both in embryonic development and in the adult nervous system, and may regulate hippocampal neurogenesis. Previous data indicated that increased expression of BMP4 mRNA within the dentate gyrus might contribute to decreased hippocampal cell proliferation in the APP{sub swe}/PS1{submore » {Delta}E9} mouse AD model. However, it is not known whether the BMP antagonist Noggin contributes to the regulation of neurogenesis. We therefore studied the relative expression levels and localization of BMP4 and its antagonist Noggin in the dentate gyrus and whether these correlated with changes in neurogenesis in 6-12 mo old APP{sub swe}/PS1{sub {Delta}E9} transgenic mice. Bromodeoxyuridine (BrdU) was used to label proliferative cells. We report that decreased neurogenesis in the APP/PS1 transgenic mice was accompanied by increased expression of BMP4 and decreased expression of Noggin at both the mRNA and protein levels; statistical analysis showed that the number of proliferative cells at different ages correlated positively with Noggin expression and negatively with BMP4 expression. Intraventricular administration of a chimeric Noggin/Fc protein was used to block the action of endogenous BMP4; this resulted in a significant increase in the number of BrdU-labeled cells in dentate gyrus subgranular zone and hilus in APP/PS1 mice. These results suggest that BMP4 and Noggin co-modulate neurogenesis.« less

  19. Binaural masking release in children with Down syndrome.

    PubMed

    Porter, Heather L; Grantham, D Wesley; Ashmead, Daniel H; Tharpe, Anne Marie

    2014-01-01

    Binaural hearing results in a number of listening advantages relative to monaural hearing, including enhanced hearing sensitivity and better speech understanding in adverse listening conditions. These advantages are facilitated in part by the ability to detect and use interaural cues within the central auditory system. Binaural hearing for children with Down syndrome could be impacted by multiple factors including, structural anomalies within the peripheral and central auditory system, alterations in synaptic communication, and chronic otitis media with effusion. However, binaural hearing capabilities have not been investigated in these children. This study tested the hypothesis that children with Down syndrome experience less binaural benefit than typically developing peers. Participants included children with Down syndrome aged 6 to 16 years (n = 11), typically developing children aged 3 to 12 years (n = 46), adults with Down syndrome (n = 3), and adults with no known neurological delays (n = 6). Inclusionary criteria included normal to near-normal hearing sensitivity. Two tasks were used to assess binaural ability. Masking level difference (MLD) was calculated by comparing threshold for a 500-Hz pure-tone signal in 300-Hz wide Gaussian noise for N0S0 and N0Sπ signal configurations. Binaural intelligibility level difference was calculated using simulated free-field conditions. Speech recognition threshold was measured for closed-set spondees presented from 0-degree azimuth in speech-shaped noise presented from 0-, 45- and 90-degree azimuth, respectively. The developmental ability of children with Down syndrome was estimated and information regarding history of otitis media was obtained for all child participants via parent survey. Individuals with Down syndrome had higher masked thresholds for pure-tone and speech stimuli than typically developing individuals. Children with Down syndrome had significantly smaller MLDs than typically developing children. Adults with Down syndrome and control adults had similar MLDs. Similarities in simulated spatial release from masking were observed for all groups for the experimental parameters used in this study. No association was observed for any measure of binaural ability and developmental age for children with Down syndrome. Similar group psychometric functions were observed for children with Down syndrome and typically developing children in most instances, suggesting that attentiveness and motivation contributed equally to performance for both groups on most tasks. The binaural advantages afforded to typically developing children, such as enhanced hearing sensitivity in noise, were not as robust for children with Down syndrome in this study. Children with Down syndrome experienced less binaural benefit than typically developing peers for some stimuli, suggesting that they could require more favorable signal-to-noise ratios to achieve optimal performance in some adverse listening conditions. The reduced release from masking observed for children with Down syndrome could represent a delay in ability rather than a deficit that persists into adulthood. This could have implications for the planning of interventions for individuals with Down syndrome.

  20. Averting the foul taste of pediatric medicines improves adherence and can be lifesaving - Pheburane® (sodium phenylbutyrate).

    PubMed

    Koren, Gideon; Rieder, Michael J; Amitai, Yona

    2016-01-01

    Children's aversions to poor and mostly bitter tastes and their inability to swallow tablets and capsules are major challenges in pediatric medicine. Sodium phenylbutyrate (NaPB) is a lifesaving waste nitrogen, alternative to urea nitrogen, for individuals suffering from urea cycle disorders. A major issue in the use of NaPB is its highly foul taste, which often leads to children being unable to consume it, resulting in ineffective treatment, or alternatively, necessitating the application of the drug through a nasogastric tube or gastrostomy. This study reviews the published data on a novel formulation of NaPB, Pheburane ® granules, which begin to release their NaPB after a lag time of ~10 seconds followed by a slow release over several minutes. The taste-masked granule formulation of NaPB dramatically improves the acceptability of the drug by children and appears in initial studies to be both safe and effective. While more studies are needed to substantiate and enrich these initial trials, the available data provide a telling example where masking the drug taste of medicine for children can sometimes be the difference between life and death.

  1. Averting the foul taste of pediatric medicines improves adherence and can be lifesaving – Pheburane® (sodium phenylbutyrate)

    PubMed Central

    Koren, Gideon; Rieder, Michael J; Amitai, Yona

    2016-01-01

    Background Children’s aversions to poor and mostly bitter tastes and their inability to swallow tablets and capsules are major challenges in pediatric medicine. Sodium phenylbutyrate (NaPB) is a lifesaving waste nitrogen, alternative to urea nitrogen, for individuals suffering from urea cycle disorders. A major issue in the use of NaPB is its highly foul taste, which often leads to children being unable to consume it, resulting in ineffective treatment, or alternatively, necessitating the application of the drug through a nasogastric tube or gastrostomy. Methods This study reviews the published data on a novel formulation of NaPB, Pheburane® granules, which begin to release their NaPB after a lag time of ~10 seconds followed by a slow release over several minutes. Results The taste-masked granule formulation of NaPB dramatically improves the acceptability of the drug by children and appears in initial studies to be both safe and effective. Conclusion While more studies are needed to substantiate and enrich these initial trials, the available data provide a telling example where masking the drug taste of medicine for children can sometimes be the difference between life and death. PMID:27799750

  2. Learning and navigation of hornets: role of the various light perceiving organs.

    PubMed

    Kirshboim, S; Ishay, J S

    2001-01-01

    The present study reports on experiments carried out on workers of Vespa orientalis (Hymenoptera, Vespinae). The experiments involved: learning of the workers upon their breeding box, evaluation of their ability to navigate back to the breeding box from ever increasing distances, and the effect which masking the various light perceiving organs has on the homing flight of hornets. The test hornets were removed from their breeding box to which they became accustomed and then released at gradually increasing distances from it (100 to 1000 meters) so as to assess their ability to return home. The group of hornets returning from a given distance was on the next day released at a greater distance, and so forth, and their homing capability was then compared between regular control groups and hornets that were coated with masking paint in various light-perceiving regions such as the clypeus, frons, ocelli and ommatidia on the head or segments 3 or 4 of the gaster, the whole gaster or various combinations of the two (head and gaster). It was found that in all the groups combined (test + various controls) only about 44% of hornets released at a distance of 100 meters from the breeding box, found their way home. The percentage of homing hornets diminished with increasing distance from home and generally they responded in accordance with the formula: S(d)=exp(dp/beta), where d=distance; S(d)=the proportion of hornets expected to return from d; P=the shape parameter of the distribution: beta=the 'scale' parameter of the distribution. Percentage of successfully homing hornets was significantly larger in control hornets than in treated ones only at a release distance of 1000 meters.

  3. Developing a new formulation of sodium phenylbutyrate.

    PubMed

    Guffon, Nathalie; Kibleur, Yves; Copalu, William; Tissen, C; Breitkreutz, Joerg

    2012-12-01

    Sodium phenylbutyrate (NaPB) is used as a treatment for urea cycle disorders (UCD). However, the available, licensed granule form has an extremely bad taste, which can compromise compliance and metabolic control. A new, taste-masked, coated-granule formulation (Luc 01) under development was characterised for its in vitro taste characteristics, dissolution profiles and bioequivalence compared with the commercial product. Taste, safety and tolerability were also compared in healthy adult volunteers. The in vitro taste profile of NaPB indicated a highly salty and bitter tasting molecule, but Luc 01 released NaPB only after a lag time of ∼10 s followed by a slow release over a few minutes. In contrast, the licensed granules released NaPB immediately. The pharmacokinetic study demonstrated the bioequivalence of a single 5 g dose of the two products in 13 healthy adult volunteers. No statistical difference was seen either for maximal plasma concentration (C(max)) or for area under the plasma concentration-time curve (AUC). CI for C(max) and AUC(0-inf) of NaPB were included in the bioequivalence range of 0.80-1.25. One withdrawal for vomiting and five reports of loss of taste perception (ageusia) were related to the licensed product. Acceptability, bitterness and saltiness assessed immediately after administration indicated a significant preference for Luc 01 (p<0.01), confirming the results of the taste prediction derived from in vitro measurements. In vitro dissolution, in vitro and in vivo taste profiles support the view that the newly developed granules can be swallowed before release of the bitter active substance, thus avoiding stimulation of taste receptors. Moreover, Luc 01 was shown to be bioequivalent to the licensed product. The availability of a taste-masked form should improve compliance which is critical to the efficacy of NaPB treatment in patients with UCD.

  4. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  5. VizieR Online Data Catalog: KiDS-ESO-DR2 multi-band source catalog (de Jong+, 2015)

    NASA Astrophysics Data System (ADS)

    de Jong, J. T. A.; Verdoes Kleijn, G. A.; Boxhoorn, D. R.; Buddelmeijer, H.; Capaccioli, M.; Getman, F.; Grado, A.; Helmich, E.; Huang, Z.; Irisarri, N.; Kuijken, K.; La Barbera, F.; McFarland, J. P.; Napolitano, N. R.; Radovich, M.; Sikkema, G.; Valentijn, E. A.; Begeman, K. G.; Brescia, M.; Cavuoti, S.; Choi, A.; Cordes, O.-M.; Covone, G.; Dall'Ora, M.; Hildebrandt, H.; Longo, G.; Nakajima, R.; Paolillo, M.; Puddu, E.; Rifatto, A.; Tortora, C.; van Uitert, E.; Buddendiek, A.; Harnois-Deraps, J.; Erben, T.; Eriksen, M. B.; Heymans, C.; Hoekstra, H.; Joachimi, B.; Kitching, T. D.; Klaes, D.; Koopmans, L. V. E.; Koehlinger, F.; Roy, N.; Sifon, C.; Schneider, P.; Sutherland, W. J.; Viola, M.; Vriend, W.-J.

    2016-10-01

    KiDS data releases consist of ~1 square degree tiles that have been successfully observed in all four survey filters (u,g,r,i). The second data release (KiDS-ESO-DR2) was available in February 2015 and contains imaging data, masks and single-band source lists for all tiles observed in all four filters for which observations were completed during the second year of regular operations (1 October 2012 to 31 September 2013), a total of 98 tiles. Apart from the data products mentioned above, KiDS-ESO-DR2 also provides a multi-band source catalogue based on the combined set of 148 tiles released in the first two data releases. A complete list of all tiles with data quality parameters can be found on the KiDS website: http://kids.strw.leidenuniv.nl/DR2/ (1 data file).

  6. β-Glucans Are Masked but Contribute to Pulmonary Inflammation During Pneumocystis Pneumonia.

    PubMed

    Kutty, Geetha; Davis, A Sally; Ferreyra, Gabriela A; Qiu, Ju; Huang, Da Wei; Sassi, Monica; Bishop, Lisa; Handley, Grace; Sherman, Brad; Lempicki, Richard; Kovacs, Joseph A

    2016-09-01

    β-glucans, which can activate innate immune responses, are a major component in the cell wall of the cyst form of Pneumocystis In the current study, we examined whether β-1,3-glucans are masked by surface proteins in Pneumocystis and what role β-glucans play in Pneumocystis-associated inflammation. For 3 species, including Pneumocystis jirovecii, which causes Pneumocystis pneumonia in humans, Pneumocystis carinii, and Pneumocystis murina, β-1,3-glucans were masked in most organisms, as demonstrated by increased exposure following trypsin treatment. Using quantitative polymerase chain reaction and microarray techniques, we demonstrated in a mouse model of Pneumocystis pneumonia that treatment with caspofungin, an inhibitor of β-1,3-glucan synthesis, for 21 days decreased expression of a broad panel of inflammatory markers, including interferon γ, tumor necrosis factor α, interleukin 1β, interleukin 6, and multiple chemokines/chemokine ligands. Thus, β-glucans in Pneumocystis cysts are largely masked, which likely decreases innate immune activation; this mechanism presumably was developed for interactions with immunocompetent hosts, in whom organism loads are substantially lower. In immunosuppressed hosts with a high organism burden, organism death and release of glucans appears to be an important contributor to deleterious host inflammatory responses. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  7. Yetter-Drinfeld modules for Hom-bialgebras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makhlouf, Abdenacer, E-mail: Abdenacer.Makhlouf@uha.fr; Panaite, Florin, E-mail: Florin.Panaite@imar.ro

    The aim of this paper is to define and study Yetter-Drinfeld modules over Hom-bialgebras, a generalized version of bialgebras obtained by modifying the algebra and coalgebra structures by a homomorphism. Yetter-Drinfeld modules over a Hom-bialgebra with bijective structure map provide solutions of the Hom-Yang-Baxter equation. The category H/HYD of Yetter-Drinfeld modules with bijective structure maps over a Hom-bialgebra H with bijective structure map can be organized, in two different ways, as a quasi-braided pre-tensor category. If H is quasitriangular (respectively, coquasitriangular) the first (respectively, second) quasi-braided pre-tensor category H/HYD contains, as a quasi-braided pre-tensor subcategory, the category of modules (respectively,more » comodules) with bijective structure maps over H.« less

  8. Taste-masked and affordable donepezil hydrochloride orally disintegrating tablet as promising solution for non-compliance in Alzheimer's disease patients.

    PubMed

    Liew, Kai Bin; Tan, Yvonne Tze Fung; Peh, Kok Khiang

    2015-04-01

    Manufacturing process and superdisintegrants used in orally disintegrating tablet (ODT) formulation are often time discussed. However, the effect of suitable filler for ODT formulation is not explored thoroughly. The aim of this study was to develop a novel taste masked and affordable donepezil hydrochloride ODT with fast disintegration time and stable to improve medication compliance of Alzheimer's disease patient. The ODT was manufactured using simple wet-granulation method. Crospovidone XL-10 was used as superdisintegrant and optimization was done by comparing the effect of three grades of lactose monohydrate compound as filler: Starlac®, Flowlac® and Tablettose®. Formulations containing higher amount of colloidal silicon dioxide showed increase in hardness, weight, disintegration time and wetting time after stability study. Formulation E which containing 50% of Starlac® was found with shortest in vitro disintegration time (21.7 ± 1.67 s), in vivo disintegration time (24.0 ± 1.05 s) and in vitro disintegration time in artificial salvia (22.5 ± 1.67 s). Physical stability studies at 40 °C/75% RH for 6 months, Fourier transform infrared spectroscopy analysis and X-ray diffraction results showed that the formulation was stable. The drug-released profile showed that 80% of donepezil hydrochloride was released within 1 min. A single-dose, fasting, four-period, seven-treatment, double-blinded study involving 16 healthy human volunteers was performed to evaluate the palatability of ODT. Formulation VII containing 10 mg of ammonium glycyrrhizinate was able to mask the bitter taste of the drug. The product has the potential to be commercialized and it might serve as solution for non-compliance among the Alzheimer's disease patients.

  9. Development of Oral Flexible Tablet (OFT) Formulation for Pediatric and Geriatric Patients: a Novel Age-Appropriate Formulation Platform.

    PubMed

    Chandrasekaran, Prabagaran; Kandasamy, Ruckmani

    2017-08-01

    Development of palatable formulations for pediatric and geriatric patients involves various challenges. However, an innovative development with beneficial characteristics of marketed formulations in a single formulation platform was attempted. The goal of this research was to develop solid oral flexible tablets (OFTs) as a platform for pediatrics and geriatrics as oral delivery is the most convenient and widely used mode of drug administration. For this purpose, a flexible tablet formulation using cetirizine hydrochloride as model stability labile class 1 and 3 drug as per the Biopharmaceutical Classification System was developed. Betadex, Eudragit E100, and polacrilex resin were evaluated as taste masking agents. Development work focused on excipient selection, formulation processing, characterization methods, stability, and palatability testing. Formulation with a cetirizine-to-polacrilex ratio of 1:2 to 1:3 showed robust physical strength with friability of 0.1% (w/w), rapid in vitro dispersion within 30 s in 2-6 ml of water, and 0.2% of total organic and elemental impurities. Polacrilex resin formulation shows immediate drug release within 30 min in gastric media, better taste masking, and acceptable stability. Hence, it is concluded that ion exchange resins can be appropriately used to develop taste-masked, rapidly dispersible, and stable tablet formulations with tailored drug release suitable for pediatrics and geriatrics. Flexible formulations can be consumed as swallowable, orally disintegrating, chewable, and as dispersible tablets. Flexibility in dose administration would improve compliance in pediatrics and geriatrics. This drug development approach using ion exchange resins can be a platform for formulating solid oral flexible drug products with low to medium doses.

  10. Melt-in-Mouth Multi-particulate System for the Treatment of ADHD: A Convenient Platform for Pediatric Use.

    PubMed

    Patadia, Jalashri; Tripathi, Rahul; Joshi, Amita

    2016-08-01

    Generally, pellets obtained from extrusion/spheronization, containing microcrystalline cellulose (MCC), do not disintegrate. An attempt has been made to develop melt-in-mouth pellets of taste-masked atomoxetine hydrochloride, using extrusion-spheronization, for pediatric patients. Melt-in-mouth pellets were prepared using extrusion-spheronization method and optimized using 3(3) FFD. MCC (X1, %), mannitol (X2, %) and Indion 414: Pharmaburst 500 ratio (X3, ratio) were the factors (independent variables) studied, whereas responses studied (dependent variables) were friability (Y1, %), yield (Y2, %) shape (Y3, roundness) in vitro disintegration time (Y4, seconds). The optimized formulation obtained from FFD was characterized for friability, shape and morphology, in vitro disintegration time, porosity, moisture uptake, in vitro release study and in vivo taste and disintegration time in healthy human volunteers. Randomized, two-treatment, two-sequence, two-period, single dose, crossover sensory evaluation study of taste-masked melt-in-mouth pellet was carried out in 10 healthy human subjects. A statistically significant polynomial mathematical relationship was generated between the factors and responses to obtain an optimized formulation. The optimized formulation was characterized (in vitro and in vivo) and exhibited a rapid drug release in vitro attributed to fast disintegration of pellets and high solubility of drug in 0.1 N HCl and buffer (pH 6.8). In vivo, 40% of volunteers ranked taste-masked optimized formulation as slightly bitter while 60% ranked it as no taste. The optimized pellets were conveniently administered in volunteers and exhibited rapid in-vivo disintegration in the oral cavity. Melt-in-mouth pellets can be a used as a platform technology for administering drugs to paediatric patients accurately and conveniently resulting in patient compliance.

  11. Measuring Temporal Resolution (Release of Masking) with a Hughson-Westlake Up-Down Instead of a Békèsy-Tracking Procedure.

    PubMed

    Rhebergen, Koenraad S; van Esch, Thamar E M; Dreschler, Wouter A

    2015-06-01

    A temporal resolution test in addition to the pure-tone audiogram may be of great clinical interest because of its relevance in speech perception and expected relevance in hearing aid fitting. Larsby and Arlinger developed an appropriate clinical test, but this test uses a Békèsy-tracking procedure for estimating masked thresholds in stationary and interrupted noise to assess release of masking (RoM) for temporal resolution. Generally the Hughson-Westlake up-down procedure is used in the clinic to measure the pure-tone thresholds in quiet. A uniform approach will facilitate clinical application and might be appropriate for RoM measurements as well. Because there is no golden standard for measuring the RoM in the clinic, we examine in the present study the Hughson-Westlake up-down procedure to measure the RoM and compare the results with the Békèsy-tracking procedure. The purpose of the current study was to examine the differences between a Békèsy-tracking procedure and the Hughson-Westlake up-down procedure for estimating masked thresholds in stationary and interrupted noise to assess RoM. RoM is assessed in eight normal-hearing (NH) and ten hearing-impaired (HI) listeners through both methods. Results from both methods are compared with each other and with predicted thresholds from a model. Wilcoxon signed-rank tests, paired t tests. Some differences between the two methods were found. We used a model to quantify the results of the two measurement procedures. The results of the Hughson-Westlake procedure were clearly better in agreement with the model than the results of the Békèsy-tracking procedure. Furthermore, the Békèsy-tracking procedure showed more spread in the results of the NH listeners than the Hughson-Westlake procedure. The Hughson-Westlake procedure seems to be an applicable alternative for measuring RoM for temporal resolution in the clinical audiological practice. American Academy of Audiology.

  12. Planck 2015 results: XXII. A map of the thermal Sunyaev-Zeldovich effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aghanim, N.; Arnaud, M.; Ashdown, M.

    In this article, we have constructed all-sky Compton parameters maps, y-maps, of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 30 to 857 GHz frequency channel maps from the Planck satellite. These reconstructed y-maps are delivered as part of the Planck 2015 release. The y-maps are characterized in terms of noise properties and residual foreground contamination, mainly thermal dust emission at large angular scales, and cosmic infrared background and extragalactic point sources at small angular scales. Specific masks are defined to minimize foreground residuals and systematics. Using these masks, we compute the y-map angularmore » power spectrum and higher order statistics. From these we conclude that the y-map is dominated by tSZ signal in the multipole range, 20« less

  13. Planck 2015 results: XXII. A map of the thermal Sunyaev-Zeldovich effect

    DOE PAGES

    Aghanim, N.; Arnaud, M.; Ashdown, M.; ...

    2016-09-20

    In this article, we have constructed all-sky Compton parameters maps, y-maps, of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 30 to 857 GHz frequency channel maps from the Planck satellite. These reconstructed y-maps are delivered as part of the Planck 2015 release. The y-maps are characterized in terms of noise properties and residual foreground contamination, mainly thermal dust emission at large angular scales, and cosmic infrared background and extragalactic point sources at small angular scales. Specific masks are defined to minimize foreground residuals and systematics. Using these masks, we compute the y-map angularmore » power spectrum and higher order statistics. From these we conclude that the y-map is dominated by tSZ signal in the multipole range, 20« less

  14. Reception thresholds for sentences in quiet, continuous noise, and interrupted noise in school-age children.

    PubMed

    Stuart, Andrew

    2008-02-01

    Sentence recognition in noise was employed to investigate the development of temporal resolution in school-age children. Eighty children aged 6 to 15 years and 16 young adults participated. Reception thresholds for sentences (RTSs) were determined in quiet and in backgrounds of competing continuous and interrupted noise. In the noise conditions, RTSs were determined with a fixed noise level. RTSs were higher in quiet for six- to seven-year-old children (p = .006). Performance was better in the interrupted noise evidenced by lower RTS signal-to-noise ratios (S/Ns) relative to continuous noise (p < .0001). An effect of age was found in noise (p < .0001) where RTS S/Ns decreased with increasing age. Specifically, children under 14 years performed worse than adults. "Release from masking" was computed by subtracting RTS S/Ns in interrupted noise from continuous noise for each participant. There was no significant difference in RTS S/N difference scores as a function of age (p = .057). Children were more adversely affected by noise and needed greater S/Ns in order to perform as well as adults. Since there was no effect of age on the amount of release from masking, one can suggest that school-age children have inherently poorer processing efficiency rather than temporal resolution.

  15. Listening to Sentences in Noise: Revealing Binaural Hearing Challenges in Patients with Schizophrenia.

    PubMed

    Abdul Wahab, Noor Alaudin; Zakaria, Mohd Normani; Abdul Rahman, Abdul Hamid; Sidek, Dinsuhaimi; Wahab, Suzaily

    2017-11-01

    The present, case-control, study investigates binaural hearing performance in schizophrenia patients towards sentences presented in quiet and noise. Participants were twenty-one healthy controls and sixteen schizophrenia patients with normal peripheral auditory functions. The binaural hearing was examined in four listening conditions by using the Malay version of hearing in noise test. The syntactically and semantically correct sentences were presented via headphones to the randomly selected subjects. In each condition, the adaptively obtained reception thresholds for speech (RTS) were used to determine RTS noise composite and spatial release from masking. Schizophrenia patients demonstrated significantly higher mean RTS value relative to healthy controls (p=0.018). The large effect size found in three listening conditions, i.e., in quiet (d=1.07), noise right (d=0.88) and noise composite (d=0.90) indicates statistically significant difference between the groups. However, noise front and noise left conditions show medium (d=0.61) and small (d=0.50) effect size respectively. No statistical difference between groups was noted in regards to spatial release from masking on right (p=0.305) and left (p=0.970) ear. The present findings suggest an abnormal unilateral auditory processing in central auditory pathway in schizophrenia patients. Future studies to explore the role of binaural and spatial auditory processing were recommended.

  16. Photo-triggered fluorescent theranostic prodrugs as DNA alkylating agents for mechlorethamine release and spatiotemporal monitoring.

    PubMed

    Cao, Yanting; Pan, Rong; Xuan, Weimin; Wei, Yongyi; Liu, Kejian; Zhou, Jiahong; Wang, Wei

    2015-06-28

    We describe a new theranostic strategy for selective delivery and spatiotemporal monitoring of mechlorethamine, a DNA alkylating agent. A photo-responsive prodrug is designed and composed of a photolabile o-nitrophenylethyl group, a DNA alkylating mechlorethamine drug and a coumarin fluorophore. Masking of the "N" in mechlorethamine in a positively charged state in the prodrug renders it inactive, non-toxic, selective and non-fluorescent. Indeed, the stable prodrug shows negligible cytotoxicity towards normal cells with and without UV activation and is completely non-fluorescent. However, upon photo-irradiation, the active mechlorethamine is released and induces efficient DNA cross-links, accompanied by a strong fluorescence enhancement (152 fold). Furthermore, DNA cross-linking activity from the release can be transformed into anticancer activity observed in in vitro studies of tumor cells. Importantly, the drug release progress and the movement can be conveniently monitored by fluorescence spectroscopy. The mechanistic study proves that the DNA cross-linking activity is mainly due to the release of DNA alkylating mechlorethamine. Altogether, the studies show the power of the theranostic strategy for efficient therapy in cancer treatment.

  17. Physical Approaches to Masking Bitter Taste: Lessons from Food and Pharmaceuticals

    PubMed Central

    Hayes, John E.

    2016-01-01

    Many drugs and desirable phytochemicals are bitter, and bitter tastes are aversive. Food and pharmaceutical manufacturers share a common need for bitterness-masking strategies that allow them to deliver useful quantities of the active compounds in an acceptable form and in this review we compare and contrast the challenges and approaches by researchers in both fields. We focus on physical approaches, i.e., micro- or nano-structures to bind bitter compounds in the mouth, yet break down to allow release after they are swallowed. In all of these methods, the assumption is the degree of bitterness suppression depends on the concentration of bitterant in the saliva and hence the proportion that is bound. Surprisingly, this hypothesis has only rarely been fully tested using a combination of adequate human sensory trials and measurements of binding. This is especially true in pharmaceutical systems, perhaps due to the greater experimental challenges in sensory analysis of drugs. PMID:25205460

  18. Applications of terahertz-pulsed technology in the pharmaceutical industry

    NASA Astrophysics Data System (ADS)

    Taday, Philip F.

    2010-02-01

    Coatings are applied to pharmaceutical tablets (or pills) to for either cosmetic or release control reasons. Cosmetic coatings control the colour or to mask the taste of an active ingredient; the thickness of these coating is not critical to the performance of the product. On the other hand the thickness and uniformity of a controlled release coating has been found affect the release of the active ingredient. In this work we have obtained from a pharmacy single brand of pantoprazole tablet and mapped them using terahertz pulsed imaging (TPI) prior to additional dissolution testing. Three terahertz parameters were derived for univariate analysis for each layer: coating thickness, terahertz electric field peak strength and terahertz interface index. These parameters were then correlated dissolution tested. The best fit was found to be with combined coating layer thickness of the inert layer and enteric coating. The commercial tablets showed a large variation in coating thickness.

  19. Development and characterisation of electrospun timolol maleate-loaded polymeric contact lens coatings containing various permeation enhancers.

    PubMed

    Mehta, Prina; Al-Kinani, Ali A; Arshad, Muhammad Sohail; Chang, Ming-Wei; Alany, Raid G; Ahmad, Zeeshan

    2017-10-30

    Despite exponential growth in research relating to sustained and controlled ocular drug delivery, anatomical and chemical barriers of the eye still pose formulation challenges. Nanotechnology integration into the pharmaceutical industry has aided efforts in potential ocular drug device development. Here, the integration and in vitro effect of four different permeation enhancers (PEs) on the release of anti-glaucoma drug timolol maleate (TM) from polymeric nanofiber formulations is explored. Electrohydrodynamic (EHD) engineering, more specifically electrospinning, was used to engineer nanofibers (NFs) which coated the exterior of contact lenses. Parameters used for engineering included flow rates ranging from 8 to 15μL/min and a novel EHD deposition system was used; capable of hosting four lenses, masked template and a ground electrode to direct charged atomised structures. SEM analysis of the electrospun structures confirmed the presence of smooth nano-fibers; whilst thermal analysis confirmed the stability of all formulations. In vitro release studies demonstrated a triphasic release; initial burst release with two subsequent sustained release phases with most of the drug being released after 24h (86.7%) Biological evaluation studies confirmed the tolerability of all formulations tested with release kinetics modelling results showing drug release was via quasi-Fickian or Fickian diffusion. There were evident differences (p<0.05) in TM release dependant on permeation enhancer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  20. A novel approach to mask defect inspection

    NASA Astrophysics Data System (ADS)

    Sagiv, Amir; Shirman, Yuri; Mangan, Shmoolik

    2008-10-01

    Memory chips, now constituting a major part of semiconductor market, posit a special challenge for inspection, as they are generally produced with the smallest half-pitch available with today's technology. This is true, in particular, to photomasks of advanced memory devices, which are at the forefront of the "low-k1" regime. In this paper we present a novel photomask inspection approach, that is particularly suitable for low-k1 layers of advanced memory chips, owing to their typical dense and periodic structure. The method we present can produce a very strong signal for small mask defects, by suppression of the modulation of the pattern's image. Unlike dark-field detection, however, here a single diffraction order associated with the pattern generates a constant "gray" background image, that is used for signal enhancement. We define the theoretical basis for the new detection technique, and show, both analytically and numerically, that it can easily achieve a detection line past the printability spec, and that in cases it is at least as sensitive as high-resolution based detection. We also demonstrate this claim experimentally on a customer mask, using the platform of Applied Material's newly released Aera2TM mask inspection tool. The high sensitivity demonstrates the important and often overlooked concept that resolution is not synonymous with sensitivity. The novel detection method is advantageous in several other aspects, such as the very simple implementation, the high throughput, and the relatively simple pre- and post-processing algorithms required for signal extraction. These features, and in particular the very high sensitivity, make this novel detection method an attractive inspection option for advanced memory devices.

  1. Spatial hearing ability of the pigmented Guinea pig (Cavia porcellus): Minimum audible angle and spatial release from masking in azimuth.

    PubMed

    Greene, Nathaniel T; Anbuhl, Kelsey L; Ferber, Alexander T; DeGuzman, Marisa; Allen, Paul D; Tollin, Daniel J

    2018-08-01

    Despite the common use of guinea pigs in investigations of the neural mechanisms of binaural and spatial hearing, their behavioral capabilities in spatial hearing tasks have surprisingly not been thoroughly investigated. To begin to fill this void, we tested the spatial hearing of adult male guinea pigs in several experiments using a paradigm based on the prepulse inhibition (PPI) of the acoustic startle response. In the first experiment, we presented continuous broadband noise from one speaker location and switched to a second speaker location (the "prepulse") along the azimuth prior to presenting a brief, ∼110 dB SPL startle-eliciting stimulus. We found that the startle response amplitude was systematically reduced for larger changes in speaker swap angle (i.e., greater PPI), indicating that using the speaker "swap" paradigm is sufficient to assess stimulus detection of spatially separated sounds. In a second set of experiments, we swapped low- and high-pass noise across the midline to estimate their ability to utilize interaural time- and level-difference cues, respectively. The results reveal that guinea pigs can utilize both binaural cues to discriminate azimuthal sound sources. A third set of experiments examined spatial release from masking using a continuous broadband noise masker and a broadband chirp signal, both presented concurrently at various speaker locations. In general, animals displayed an increase in startle amplitude (i.e., lower PPI) when the masker was presented at speaker locations near that of the chirp signal, and reduced startle amplitudes (increased PPI) indicating lower detection thresholds when the noise was presented from more distant speaker locations. In summary, these results indicate that guinea pigs can: 1) discriminate changes in source location within a hemifield as well as across the midline, 2) discriminate sources of low- and high-pass sounds, demonstrating that they can effectively utilize both low-frequency interaural time and high-frequency level difference sound localization cues, and 3) utilize spatial release from masking to discriminate sound sources. This report confirms the guinea pig as a suitable spatial hearing model and reinforces prior estimates of guinea pig hearing ability from acoustical and physiological measurements. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Forward masking as a mechanism of automatic gain control in odontocete biosonar: a psychophysical study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2008-07-01

    In a false killer whale Pseudorca crassidens, echo perception thresholds were measured using a go/no-go psychophysical paradigm and one-up-one-down staircase procedure. Computer controlled echoes were electronically synthesized pulses that were played back through a transducer and triggered by whale emitted biosonar pulses. The echo amplitudes were proportional to biosonar pulse amplitudes; echo levels were specified in terms of the attenuation of the echo sound pressure level near the animal's head relative to the source level of the biosonar pulses. With increasing echo delay, the thresholds (echo attenuation factor) decreased from -49.3 dB at 2 ms to -79.5 dB at 16 ms, with a regression slope of -9.5 dB per delay doubling (-31.5 dB per delay decade). At the longer delays, the threshold remained nearly constant around -80.4 dB. Levels of emitted pulses slightly increased with delay prolongation (threshold decrease), with a regression slope of 3.2 dB per delay doubling (10.7 dB per delay decade). The echo threshold dependence on delay is interpreted as a release from forward masking by the preceding emitted pulse. This release may compensate for the echo level decrease with distance, thus keeping the echo sensation level for the animal near constant within a certain distance range.

  3. Pharmaceutical Applications of Ion-Exchange Resins

    NASA Astrophysics Data System (ADS)

    Elder, David P.

    2005-04-01

    The historical uses of ion-exchange resins and a summary of the basic chemical principles involved in the ion-exchange process are discussed. Specific applications of ion-exchange resins are provided. The utility of these agents to stabilize drugs are evaluated. Commonly occurring chemical and physical incompatibilities are reviewed. Ion-exchange resins have found applicability as inactive pharmaceutical constituents, particularly as disintegrants (inactive tablet ingredient whose function is to rapidly disrupt the tablet matrix on contact with gastric fluid). One of the more elegant approaches to improving palatability of ionizable drugs is the use of ion-exchange resins as taste-masking agents. The selection, optimization of drug:resin ratio and particle size, together with a review of scaleup of typical manufacturing processes for taste-masked products are provided. Ion-exchange resins have been extensively utilized in oral sustained-release products. The selection, optimization of drug:resin ratio and particle size, together with a summary of commonly occurring commercial sustained-release products are discussed. Ion-exchange resins have also been used in topical products for local application to the skin, including those where drug flux is controlled by a differential electrical current (ionotophoretic delivery). General applicability of ion-exchange resins, including ophthalmic delivery, nasal delivery, use as drugs in their own right (e.g., colestyramine, formerly referred to as cholestyramine), as well as measuring gastrointestinal transit times, are discussed. Finally, pharmaceutical monographs for ion-exchange resins are reviewed.

  4. A novel fabrication method for suspended high-aspect-ratio microstructures

    NASA Astrophysics Data System (ADS)

    Yang, Yao-Joe; Kuo, Wen-Cheng

    2005-11-01

    Suspended high-aspect-ratio structures (suspended HARS) are widely used for MEMS devices such as micro-gyroscopes, micro-accelerometers, optical switches and so on. Various fabrication methods, such as SOI, SCREAM, AIM, SBM and BELST processes, were proposed to fabricate HARS. However, these methods focus on the fabrication of suspended microstructures with relatively small widths of trench opening (e.g. less than 10 µm). In this paper, we propose a novel process for fabricating very high-aspect-ratio suspended structures with large widths of trench opening using photoresist as an etching mask. By enhancing the microtrenching effect, we can easily release the suspended structure without thoroughly removing the floor polymer inside the trenches for the cases with a relatively small trench aspect ratio. All the process steps can be integrated into a single-run single-mask ICP-RIE process, which effectively reduces the process complexity and fabrication cost. We also discuss the phenomenon of corner erosion, which results in the undesired etching of silicon structures during the structure-releasing step. By using the proposed process, 100 µm thick suspended structures with the trench aspect ratio of about 20 are demonstrated. Also, the proposed process can be used to fabricate devices for applications which require large in-plane displacement. This paper was orally presented in the Transducers'05, Seoul, Korea (paper ID: 3B1.3).

  5. Influence of Exercise and Training on Critical Stages of Bone Growth and Development.

    PubMed

    Klentrou, Panagiota

    2016-05-01

    Although osteoporosis is considered a geriatric disease, factors affecting bone strength are most influential during child growth and development. This article reviews what is known and still unclear in terms of bone growth, development and adaptation relative to physical activity before and during puberty. Bone is responsive to certain exercise protocols early in puberty and less so in postpubertal years, where bone strength, rather than bone mass, being the outcome of interest. Mechanical loading and high impact exercise promote bone strength. Intense training before and during puberty, however, may negatively affect bone development. Future research should focus on increasing our mechanistic understanding of the manner by which diverse physical stressors alter the integrity of bone. Longitudinal studies that examine the extent to which muscle and bone are comodulated by growth in children are also recommended.

  6. Pediatric drug formulation of sodium benzoate extended-release granules.

    PubMed

    Combescot, E; Morat, G; de Lonlay, P; Boudy, V

    2016-01-01

    Urea cycle disorders are a group of inherited orphan diseases leading to hyperammonemia. Current therapeutic strategy includes high doses of sodium benzoate leading to three or four oral intakes per day. As this drug is currently available in capsules or in solution, children are either unable to swallow the capsule or reluctant to take the drug due to its strong bitter taste. The objective of the present study was to develop solid, multiparticulate formulations of sodium benzoate, which are suitable for pediatric patients (i.e. flavor-masked, easy to swallow and with a dosing system). Drug layering and coating in a fluidized bed were applied for preparing sustained-release granules. Two types of inert cores (GalenIQ® and Suglets®) and three different polymers (Kollicoat®, Aquacoat® and Eudragit®) were tested in order to select the most appropriate polymer and starter core for our purpose. Physical characteristics and drug release profiles of the pellets were evaluated. A Suglets® core associated with a Kollicoat® coating seems to be the best combination for an extended release of sodium benzoate. A curing period of 8 h was necessary to complete film formation and the resulting drug release pattern was found to be dependent of the acidity of the release medium.

  7. Microphase separation in solid lipid dosage forms as the cause of drug release instability.

    PubMed

    Lopes, Diogo Gomes; Koutsamanis, Ioannis; Becker, Karin; Scheibelhofer, Otto; Laggner, Peter; Haack, Detlev; Stehr, Michael; Zimmer, Andreas; Salar-Behzadi, Sharareh

    2017-01-30

    Although lipid excipients are of increasing interest for development of taste-masked and modified release formulations, the drug release instability and the lack of mechanistic understanding in that regard still prevent their larger-scale application. In this work, we investigated the physical stability of a binary (tripalmitin/polysorbate 65) lipid coating formulation with a known stable polymorphism. The coating composition was characterized using DSC to construct the phase diagram of binary system and polarized light microscopy to display the microstructure organization. The water uptake and the erosion of slabs cast from the coating formulations were investigated post-production and after storage. Subsequently, N-acetylcysteine particles were coated with the selected formulations and the drug release stability was investigated. Additionally, microstructure characterization was performed via SEM and X-ray diffraction. The drug release instability was explained by polysorbate 65 and tripalmitin phase growth during storage, especially at 40°C, suggesting that polysorbate 65 can leak out of tripalmitin spherulitic structures, creating lipophilic and impermeable tripalmitin regions. The growth of polysorbate 65 phase leads to larger hydrophilic channels with reduced tortuosity. This work indicates that for obtaining stable drug release profiles from advanced lipid formulations, microphase separation should be prevented during storage. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Auditory processing disorders and problems with hearing-aid fitting in old age.

    PubMed

    Antonelli, A R

    1978-01-01

    The hearing handicap experienced by elderly subjects depends only partially on end-organ impairment. Not only the neural unit loss along the central auditory pathways contributes to decreased speech discrimination, but also learning processes are slowed down. Diotic listening in elderly people seems to fasten learning of discrimination in critical conditions, as in the case of sensitized speech. This fact, and the binaural gain through the binaural release from masking, stress the superiority, on theoretical grounds, of binaural over monaural hearing-aid fitting.

  9. Design and Fabrication of a Strain-Powered Microelectromechanical System (MEMS) Switch

    DTIC Science & Technology

    2014-09-01

    release showing uniform folding upwards; the top edge appears to be anchored to the substrate, which necessitated a mask rewrite after reducing...underdeveloped resist causing the switch to be anchored (left), thin-film shearing at the contact edge (right), and thin- film edge anchoring (right). Geometry...a “hip” joint and an “ ankle ” joint—while a center hinge was designed to fold down at a “knee” joint and make electrical contact with an electrical

  10. Planck 2015 results. XXII. A map of the thermal Sunyaev-Zeldovich effect

    NASA Astrophysics Data System (ADS)

    Planck Collaboration; Aghanim, N.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartlett, J. G.; Bartolo, N.; Battaner, E.; Battye, R.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bock, J. J.; Bonaldi, A.; Bonavera, L.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Butler, R. C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chiang, H. C.; Christensen, P. R.; Churazov, E.; Clements, D. L.; Colombo, L. P. L.; Combet, C.; Comis, B.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; Davis, R. J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Désert, F.-X.; Dickinson, C.; Diego, J. M.; Dolag, K.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T. A.; Eriksen, H. K.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Génova-Santos, R. T.; Giard, M.; González-Nuevo, J.; Górski, K. M.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J. E.; Hansen, F. K.; Harrison, D. L.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Holmes, W. A.; Hornstrup, A.; Huffenberger, K. M.; Hurier, G.; Jaffe, A. H.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lacasa, F.; Lagache, G.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Macías-Pérez, J. F.; Maffei, B.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P. G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Melchiorri, A.; Melin, J.-B.; Migliaccio, M.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Noviello, F.; Novikov, D.; Novikov, I.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Pratt, G. W.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rossetti, M.; Roudier, G.; Rubiño-Martín, J. A.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savelainen, M.; Savini, G.; Scott, D.; Spencer, L. D.; Stolyarov, V.; Stompor, R.; Sunyaev, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tramonte, D.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Wade, L. A.; Wandelt, B. D.; Wehus, I. K.; Yvon, D.; Zacchei, A.; Zonca, A.

    2016-09-01

    We have constructed all-sky Compton parameters maps, y-maps, of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 30 to 857 GHz frequency channel maps from the Planck satellite. These reconstructed y-maps are delivered as part of the Planck 2015 release. The y-maps are characterized in terms of noise properties and residual foreground contamination, mainly thermal dust emission at large angular scales, and cosmic infrared background and extragalactic point sources at small angular scales. Specific masks are defined to minimize foreground residuals and systematics. Using these masks, we compute the y-map angular power spectrum and higher order statistics. From these we conclude that the y-map is dominated by tSZ signal in the multipole range, 20 <ℓ< 600. We compare the measured tSZ power spectrum and higher order statistics to various physically motivated models and discuss the implications of our results in terms of cluster physics and cosmology.

  11. De-masking oxytocin-deficiency in craniopharyngioma and assessing its link with affective function.

    PubMed

    Gebert, Dorothea; Auer, Matthias K; Stieg, Mareike R; Freitag, Martin T; Lahne, Madlén; Fuss, Johannes; Schilbach, Katharina; Schopohl, Jochen; Stalla, Günter K; Kopczak, Anna

    2018-02-01

    Despite the high prevalence of panhypopituitarism and diabetes insipidus in patients with craniopharyngioma (CP), little is known about the functioning of the neuropeptide oxytocin in these patients. This is of special interest as tumor-associated lesions often impair sites critical for oxytocin production and release, and affective dysfunction in CP links with elsewhere reported prosocial, antidepressant and anxiolytic oxytocin effects. Using a prospective study-design, we tested whether oxytocin is reduced in CP-patients, and whether altered oxytocin levels account for affective and emotional dysfunction. 26 adult CP-patients and 26 healthy controls matched in sex and age underwent physical exercise, a stimulus previously shown to induce oxytocin release. Baseline and stimulated salivary oxytocin levels, as well as empathy, depression and anxiety scores were measured. Results showed that patients overall did not present with lower baseline oxytocin levels than controls (F[1,30]=0.21, p=0.649), but baseline oxytocin levels were indeed reduced in patients with hypothalamic damage, as assessed by MRI-based grading (F[2,9.79]=4.54, p=0.040). In response to exercise-induced stimulation, all CP-patients showed a blunted oxytocin-release compared to controls (F[1,30]=9.36, p=0.005). DI was not associated with oxytocin levels. Regarding affective function, unexpectedly, higher baseline oxytocin was related to higher trait anxiety (b=2.885, t(43)=2.421, p=0.020, CI[.478; 5.292]); the positive link with higher depression failed to reach statistical significance (b=1.928, t(43)=1.949, p=0.058, CI[-0.070; 3.927]). A blunted oxytocin-release was linked with higher state anxiety (b=-0.133, t(43)=-2.797, p=0.008, CI[-0.230; -0.037]). Empathy was not associated with oxytocin measures. In conclusion, we observed reduced baseline oxytocin levels only in CP-patients with hypothalamic damage. Exercise-induced stimulation de-masked an oxytocin-deficiency in all CP-patients. Baseline oxytocin levels and stimulated OT-responses might have different effects on affective function, which should be considered in future substitution paradigms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Mechanical loading stimulates ecto-ATPase activity in human tendon cells.

    PubMed

    Tsuzaki, M; Bynum, D; Almekinders, L; Faber, J; Banes, A J

    2005-09-01

    Response to external stimuli such as mechanical signals is critical for normal function of cells, especially when subjected to repetitive motion. Tenocytes receive mechanical stimuli from the load-bearing matrix as tension, compression, and shear stress during tendon gliding. Overloading a tendon by high strain, shear, or repetitive motion can cause matrix damage. Injury may induce cytokine expression, matrix metalloproteinase (MMP) expression and activation resulting in loss of biomechanical properties. These changes may result in tendinosis or tendinopathy. Alternatively, an immediate effector molecule may exist that acts in a signal-dampening pathway. Adenosine 5'-triphosphate (ATP) is a candidate signal blocker of mechanical stimuli. ATP suppresses load-inducible inflammatory genes in human tendon cells in vitro. ATP and other extracellular nucleotide signaling are regulated efficiently by two distinct mechanisms: purinoceptors via specific receptor-ligand binding and ecto-nucleotidases via the hydrolysis of specific nucleotide substrates. ATP is released from tendon cells by mechanical loading or by uridine 5'-triphosphate (UTP) stimulation. We hypothesized that mechanical loading might stimulate ecto-ATPase activity. Human tendon cells of surface epitenon (TSC) and internal compartment (TIF) were cyclically stretched (1 Hz, 0.035 strain, 2 h) with or without ATP. Aliquots of the supernatant fluids were collected at various time points, and ATP concentration (ATP) was determined by a luciferin-luciferase bioluminescence assay. Total RNA was isolated from TSC and TIF (three patients) and mRNA expression for ecto-nucleotidase was analyzed by RT-PCR. Human tendon cells secreted ATP in vitro (0.5-1 nM). Exogenous ATP was hydrolyzed within minutes. Mechanical load stimulated ATPase activity. ATP was hydrolyzed in mechanically loaded cultures at a significantly greater rate compared to no load controls. Tenocytes (TSC and TIF) expressed ecto-nucleotidase mRNA (ENTPD3 and ENPP1, ENPP2). These data suggest that motion may release ATP from tendon cells in vivo, where ecto-ATPase may also be activated to hydrolyze ATP quickly. Ecto-ATPase may act as a co-modulator in ATP load-signal modulation by regulating the half-life of extracellular purine nucleotides. The extracellular ATP/ATPase system may be important for tendon homeostasis by protecting tendon cells from responding to excessive load signals and activating injurious pathways. Copyright 2005 Wiley-Liss, Inc

  13. Science Highlights from the Spitzer Survey of Stellar Structure in Galaxies (S4G) & Public Release of S4G Data

    NASA Astrophysics Data System (ADS)

    Sheth, Kartik

    2013-01-01

    The Spitzer Survey of Stellar Structure in Galaxies (S4G) is the largest and the most homogenous survey of the distribution of mass and stellar structure in over 2,300 nearby galaxies. With an integration time of four minutes per pixel at 3.6 and 4.5 microns, the S4G maps are extremely deep, tracing the stellar surface densities of < 1 solar mass per square parsec! S4G is the ultimate survey of the endoskeleton of nearby galaxies from dwarfs to ellipticals and affords an incredible treasury of data which we can address a host of outstanding questions in galaxy evolution. At this special session we will present details on the public release of this survey which will include science ready images, masks for the foreground and background stars, globally integrated properties and radial profiles of all galaxies. In addition we will release the results from a GALFIT decomposition of 200 galaxies which will be supplemented with the remainder of the survey within six months. The data are being released through the NASA/IPAC Infrared Science Archive (IRSA). I will present an overview of the survey, the data we are releasing, introduce the speakers and present science highlights from the team.

  14. Short-term effects of beta-amyloid25-35 peptide aggregates on transmitter release in neuromuscular synapses.

    PubMed

    Garcia, Neus; Santafé, Manel M; Tomàs, Marta; Lanuza, Maria A; Tomàs, Josep

    2008-03-01

    The beta-amyloid (AB) peptide25-35 contains the functional domain of the AB precursor protein that is both required for neurotrophic effects in normal neural tissues and is involved in the neurotoxic effects in Alzheimer disease. We demonstrated the presence of the amyloid precursor protein/AB peptide in intramuscular axons, presynaptic motor nerve terminals, terminal and myelinating Schwann cells, and the postsynaptic and subsarcolemmal region in the Levator auris longus muscle of adult rats by immunocytochemistry. Using intracellular recording, we investigated possible short-term functional effects of the AB fragment (0.1-10 micromol/L) on acetylcholine release in adult and newborn motor end plates. We found no change in evoked, spontaneous transmitter release or resting membrane potential of the muscle cells. A previous block of the presynaptic muscarinic receptor subtypes and a previous block or stimulation of protein kinase C revealed no masked effect of the peptide on the regulation of transmitter release. The aggregated form of AB peptide25-35, however, interfered acutely with acetylcholine release (quantal content reduction) when synaptic activity was maintained by electric stimulation. The possible relevance of this inhibition of neurotransmission by AB peptide25-35 to the pathogenesis of Alzheimer remains to be determined.

  15. Variations in backward masking with different masking stimuli: II. The effects of spatially quantised masks in the light of local contour interaction, interchannel inhibition, perceptual retouch, and substitution theories.

    PubMed

    Bachmann, Talis; Luiga, Iiris; Põder, Endel

    2005-01-01

    In part I we showed that with spatially non-overlapping targets and masks both local metacontrast-like interactions and attentional processes are involved in backward masking. In this second part we extend the strategy of varying the contents of masks to pattern masking where targets and masks overlap in space, in order to compare different masking theories. Images of human faces were backward-masked by three types of spatially quantised masks (the same faces as targets, faces different from targets, and Gaussian noise with power spectra typical for faces). Configural characteristics, rather than the spectral content of the mask, predicted the extent of masking at relatively long stimulus onset asynchronies (SOAs). This poses difficulties for the theory of transient-on-sustained inhibition as the principal mechanism of masking and also for local contour interaction being a decisive factor in pattern masking. The scale of quantisation had no effect on the masking capacity of noise masks and a strong effect on the capacity of different-face masks. Also, the decrease of configural masking with an increase in the coarseness of the quantisation of the mask highlights ambiguities inherent in the re-entrance-based substitution theory of masking. Different masking theories cannot solve the problems of masking separately. They should be combined in order to create a complex, yet comprehensible mode of interaction for the different mechanisms involved in visual backward masking.

  16. The Release of Nanosilver from Consumer Products Used in the Home

    PubMed Central

    Benn, Troy; Cavanagh, Bridget; Hristovski, Kiril; Posner, Jonathan D.; Westerhoff, Paul

    2016-01-01

    Nanosilver has become one of the most widely used nanomaterials in consumer products because of its antimicrobial properties. Public concern over the potential adverse effects of nanosilver's environmental release has prompted discussion of federal regulation. In this paper, we assess several classes of consumer products for their silver content and potential to release nanosilver into water, air, or soil. Silver was quantified in a shirt, a medical mask and cloth, toothpaste, shampoo, detergent, a towel, a toy teddy bear, and two humidifiers. Silver concentrations ranged from 1.4 to 270,000 μg Ag g product−1. Products were washed in 500 mL of tap water to assess the potential release of silver into aqueous environmental matrices (wastewater, surface water, saliva, etc.). Silver was released in quantities up to 45 μg Ag g product−1, and size fractions were both larger and smaller than 100 nm. Scanning electron microscopy confirmed the presence of nanoparticle silver in most products as well as in the wash water samples. Four products were subjected to a toxicity characterization leaching procedure to assess the release of silver in a landfill. The medical cloth released an amount of silver comparable to the toxicity characterization limit. This paper presents methodologies that can be used to quantify and characterize silver and other nanomaterials in consumer products. The quantities of silver in consumer products can in turn be used to estimate real-world human and environmental exposure levels. PMID:21284285

  17. VizieR Online Data Catalog: Full spectroscopic data release of the SPT-GMOS (Bayliss+, 2016)

    NASA Astrophysics Data System (ADS)

    Bayliss, M. B.; Ruel, J.; Stubbs, C. W.; Allen, S. W.; Applegate, D. E.; Ashby, M. L. N.; Bautz, M.; Benson, B. A.; Bleem, L. E.; Bocquet, S.; Brodwin, M.; Capasso, R.; Carlstrom, J. E.; Chang, C. L.; Chiu, I.; Cho, H.-M.; Clocchiatti, A.; Crawford, T. M.; Crites, A. T.; de Haan, T.; Desai, S.; Dietrich, J. P.; Dobbs, M. A.; Doucouliagos, A. N.; Foley, R. J.; Forman, W. R.; Garmire, G. P.; George, E. M.; Gladders, M. D.; Gonzalez, A. H.; Gupta, N.; Halverson, N. W.; Hlavacek-Larrondo, J.; Hoekstra, H.; Holder, G. P.; Holzapfel, W. L.; Hou, Z.; Hrubes, J. D.; Huang, N.; Jones, C.; Keisler, R.; Knox, L.; Lee, A. T.; Leitch, E. M.; von der Linden, A.; Luong-van, D.; Mantz, A.; Marrone, D. P.; McDonald, M.; McMahon, J. J.; Meyer, S. S.; Mocanu, L. M.; Mohr, J. J.; Murray, S. S.; Padin, S.; Pryke, C.; Rapetti, D.; Reichardt, C. L.; Rest, A.; Ruhl, J. E.; Saliwanchik, B. R.; Saro, A.; Sayre, J. T.; Schaffer, K. K.; Schrabback, T.; Shirokoff, E.; Song, J.; Spieler, H. G.; Stalder, B.; Stanford, S. A.; Staniszewski, Z.; Stark, A. A.; Story, K. T.; Vanderlinde, K.; Vieira, J. D.; Vikhlinin, A.; Williamson, R.; Zenteno, A.

    2016-11-01

    The data presented in this paper follow the same observational design described by Ruel et al. (2014ApJ...792...45R). The final Gemini-S observing allocation for SPT-GMOS concluded at the end of the 2015B semester. Over the course of the entire survey we observed 121 individual spectroscopic masks targeting 62 SPT-SZ galaxy clusters (see table 1). All final data products from SPT-GMOS are publicly released via the Harvard Dataverse Network (http://dataverse.harvard.edu/dataverse/SPT_Clusters). The galaxy clusters observed in the SPT-GMOS are all drawn from the SPT-SZ survey, completed in 2011 November. The full SPT-SZ survey covered approximately 2500deg2 of the southern sky at 95, 150, and 220GHz with an angular resolution of ~1'. (4 data files).

  18. Contralateral suppression of transient otoacoustic emissions and sentence recognition in noise in young adults.

    PubMed

    Stuart, Andrew; Butler, Alyson K

    2012-10-01

    One purported role of the medial olivocochlear (MOC) efferent system is to reduce the effects of masking noise. MOC system functioning can be evaluated noninvasively in humans through contralateral suppression of otoacoustic emissions. It has been suggested that the strength of the MOC efferent activity should be positively associated with listening performance in noise. The objective of the study was to further explore this notion by examining contralateral suppression of transient evoked otoacoustic emissions (TEOAEs) and sentence recognition in two noises with normal hearing young adults. A repeated measures multivariate quasi-experimental design was employed. Thirty-two normal hearing young adult females participated. Reception thresholds for sentences (RTSs) were determined monaurally and binaurally in quiet and in competing continuous and interrupted noises. Both noises had an identical power spectrum and differed only in their temporal continuity. "Release from masking" was computed by subtracting RTS signal-to-noise ratios in interrupted from continuous noise. TEOAEs were evoked with 80 dB peSPL click stimuli. To examine contralateral suppression, TEOAEs were evaluated with 60 dB peSPL click stimuli with and without a contralateral 65 dB SPL white noise suppressor. A binaural advantage was observed for RTSs in quiet and noise (p < .0001) while there was no difference between ears (p >.05). In noise, performance was superior in the interrupted noise (i.e., RTSs were lower vs. continuous noise; p < .0001). There were no statistically significant differences in TEOAE levels between ears (p >.05). There was also no significant difference in the amount of suppression between ears (p = .41). There were no significant correlations or predictive linear relations between the amount of TEOAE suppression and any indices of sentence recognition in noise (i.e., RTS signal-to-noise ratios and release from masking; p > .05). The findings are not consistent with the notion that increased medial olivocochlear efferent feedback, as assessed via contralateral suppression of TEOAEs, is associated with improved speech perception in continuous and interrupted noise. American Academy of Audiology.

  19. Joint Service Aircrew Mask (JSAM) - Tactical Aircraft (TA) A/P22P-14A Respirator Assembly (V)5: Speech Intelligibility Performance with Double Hearing Protection, HGU-84/P Flight Helmet

    DTIC Science & Technology

    2017-04-06

    Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed below...Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication 6 DISTRIBUTION STATEMENT A: Approved for public release

  20. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  1. Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.

    PubMed

    Wood, Fiona E; Morley, Colin J; Dawson, Jennifer A; Kamlin, C Omar F; Owen, Louise S; Donath, Susan; Davis, Peter G

    2008-05-01

    Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience. (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks. Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention. A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%). Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.

  2. Retention of pediatric bag-mask ventilation efficacy skill by inexperienced medical student resuscitators using standard bag-mask ventilation masks, pocket masks, and blob masks.

    PubMed

    Kitagawa, Kory H; Nakamura, Nina M; Yamamoto, Loren

    2006-03-01

    To measure the ventilation efficacy with three single-sized mask types on infant and child manikin models. Medical students were recruited as study subjects inasmuch as they are inexperienced resuscitators. They were taught proper bag-mask ventilation (BMV) according to the American Heart Association guidelines on an infant and a child manikin. Subjects completed a BMV attempt successfully using the adult standard mask (to simulate the uncertainty of mask selection), pocket mask, and blob mask. Each attempt consisted of 5 ventilations assessed by chest rise of the manikin. Study subjects were asked which mask was easiest to use. Four to six weeks later, subjects repeated the procedure with no instructions (to simulate an emergency BMV encounter without immediate pre-encounter teaching). Forty-six volunteer subjects were studied. During the first attempt, subjects preferred the standard and blob masks over the pocket mask. For the second attempt, the blob mask was preferred over the standard mask, and few liked the pocket mask. Using the standard, blob, and pocket masks on the child manikin, 39, 42, and 20 subjects, respectively, were able to achieve adequate ventilation. Using the standard, blob, and pocket masks on the infant manikin, 45, 45, and 11 subjects, respectively, were able to achieve adequate ventilation. Both the standard and blob masks are more effective than the pocket mask at achieving adequate ventilation on infant and child manikins in this group of inexperienced medical student resuscitators, who most often preferred the blob mask.

  3. Rates of initial acceptance of PAP masks and outcomes of mask switching.

    PubMed

    Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula

    2016-05-01

    Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

  4. Testing the efficacy of homemade masks: would they protect in an influenza pandemic?

    PubMed

    Davies, Anna; Thompson, Katy-Anne; Giri, Karthika; Kafatos, George; Walker, Jimmy; Bennett, Allan

    2013-08-01

    This study examined homemade masks as an alternative to commercial face masks. Several household materials were evaluated for the capacity to block bacterial and viral aerosols. Twenty-one healthy volunteers made their own face masks from cotton t-shirts; the masks were then tested for fit. The number of microorganisms isolated from coughs of healthy volunteers wearing their homemade mask, a surgical mask, or no mask was compared using several air-sampling techniques. The median-fit factor of the homemade masks was one-half that of the surgical masks. Both masks significantly reduced the number of microorganisms expelled by volunteers, although the surgical mask was 3 times more effective in blocking transmission than the homemade mask. Our findings suggest that a homemade mask should only be considered as a last resort to prevent droplet transmission from infected individuals, but it would be better than no protection.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, Aaron P.; Carlson, Charles T.; Weaver, William T.

    A mask alignment system for providing precise and repeatable alignment between ion implantation masks and workpieces. The system includes a mask frame having a plurality of ion implantation masks loosely connected thereto. The mask frame is provided with a plurality of frame alignment cavities, and each mask is provided with a plurality of mask alignment cavities. The system further includes a platen for holding workpieces. The platen may be provided with a plurality of mask alignment pins and frame alignment pins configured to engage the mask alignment cavities and frame alignment cavities, respectively. The mask frame can be lowered ontomore » the platen, with the frame alignment cavities moving into registration with the frame alignment pins to provide rough alignment between the masks and workpieces. The mask alignment cavities are then moved into registration with the mask alignment pins, thereby shifting each individual mask into precise alignment with a respective workpiece.« less

  6. Influence of Polymer Type on the Physical Properties and Release Profile of Papaverine Hydrochloride From Hard Gelatin Capsules.

    PubMed

    Polski, Andrzej; Iwaniak, Karol; Kasperek, Regina; Modrzewska, Joanna; Sobótka-Polska, Karolina; Sławińska, Karolina; Poleszak, Ewa

    2015-01-01

    The capsule is one of the most important solid dosage forms in the pharmaceutical industry. It is easier and faster to produce than a tablet, because it requires fewer excipients. Generally, capsules are easy to swallow and mask any unpleasant taste of the substances used while their release profiles can be easily modified. Papaverine hydrochloride was used as a model substance to show different release profiles using different excipients. The main aim of the study was to analyze the impact of using different polymers on the release profile of papaverine hydrochloride from hard gelatin capsules. Six series of hard gelatin capsules containing papaverine hydrochloride as a model drug and different excipients were made. Then, the angle of repose, flow rate, mass flow rate and volume flow rate of the powders used for capsule production were analyzed. The uniform weight and disintegration time of the capsules were studied. The dissolution study was performed in a basket apparatus, while the amount of papaverine hydrochloride released was determined spectrophotometrically at 251 nm. Only one formula of powder had satisfactory flow properties, while all formulas had good Hausner ratios. The best properties were from powder containing polyvinylpyrrolidone 10k. The disintegration time of capsules varied from 1:30 min to 2:00 min. As required by Polish Pharmacopoeia X, 80% of the active substance in all cases was released within 15 minutes. The capsules with polyvinylpyrrolidone 10k were characterized by the longest release. On the other hand, capsules containing microcrystalline cellulose had the fastest release profile. Using 10% of different polymers, without changing the other excipients, had a significant impact on the physical properties of the powders and papaverine hydrochloride release profile. The two most preferred capsule formulations contained either polyvinylpyrrolidone 10k or microcrystalline cellulose.

  7. Fabricating PFPE Membranes for Capillary Electrophoresis

    NASA Technical Reports Server (NTRS)

    Lee, Michael C.; Willis, Peter A.; Greer, Frank; Rolland, Jason

    2009-01-01

    A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist).

  8. Development of the concept of spatial-temporal mask for testing effects of discharge from well-drilling activities on biological communities.

    PubMed

    Pulgati, Fernando H; Ayup-Zouain, Ricardo N; Landau, Luiz; Fachel, Jandyra M G

    2010-08-01

    This paper describes the use of Bayesian spatial models to develop the concept of a spatial-temporal mask for the purpose of identifying regions in which before and after drilling effects are most clearly defined and from which the consequences of exposure of macrofauna and meiofauna to the release of drilling discharges can be evaluated over time. To determine the effects of drilling fluids and drill-cuttings on the marine benthic community, it is essential to know not only where discharged materials ended up within the possible impact area, but also the chemical concentrations to which biota were exposed during and after drilling. Barium and light hydrocarbons were used as chemical tracers for water-based and non-aqueous-based fluids in a shallow water site in the Campos Basin, off the coast of Brazil. Since the site showed evidence of exposure to waste material from earlier drilling, the analysis needed to take into account the background concentrations of these compounds. Using the Bayesian models, concentrations at unsampled sites were predicted and regions altered and previously contaminated were identified.

  9. Occurrence and stability of masked fumonisins in corn silage samples.

    PubMed

    Latorre, Alicia; Dagnac, Thierry; Lorenzo, Bruno Fernández; Llompart, María

    2015-12-15

    Corn plants contaminated with Fusarium verticilloides were harvested at two dates and ensiled in laboratory silos. The stability of Fumonisins B1 and B2 (FB1, FB2) was studied and the effects of inoculant use (Lactobacillus buchneri) and of the ensiling time were assessed. The occurrence of masked fumonisins was also investigated. After the extraction of the free forms (FB1, FB2), the residue was subjected to an alkaline hydrolysis resulting in the release of derivates subsequently detected by LC-HESI-MS/MS. The ensiling time has shown to be a significant factor for the evolution of free FB1 and FB2 at the 2nd harvest date. Moreover, the use of inoculant had a significant effect on the stability of hidden and total FB1 at the two harvest dates. Samples previously ensiled and exposed to aerobic conditions for 7days have shown higher fumonisin levels than those not exposed to air. Our results showed that 65% and 39% of the total FB1 and FB2 contents in silage were due to hidden fumonisins. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers

    PubMed Central

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-01-01

    Objective The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. Setting 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. Participants 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Intervention Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Main outcome measure Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. Results The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. Conclusions This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. PMID:25903751

  11. THE SPITZER SURVEY OF STELLAR STRUCTURE IN GALAXIES (S{sup 4}G): MULTI-COMPONENT DECOMPOSITION STRATEGIES AND DATA RELEASE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salo, Heikki; Laurikainen, Eija; Laine, Jarkko

    The Spitzer Survey of Stellar Structure in Galaxies (S{sup 4}G) is a deep 3.6 and 4.5 μm imaging survey of 2352 nearby (<40 Mpc) galaxies. We describe the S{sup 4}G data analysis pipeline 4, which is dedicated to two-dimensional structural surface brightness decompositions of 3.6 μm images, using GALFIT3.0. Besides automatic 1-component Sérsic fits, and 2-component Sérsic bulge + exponential disk fits, we present human-supervised multi-component decompositions, which include, when judged appropriate, a central point source, bulge, disk, and bar components. Comparison of the fitted parameters indicates that multi-component models are needed to obtain reliable estimates for the bulge Sérsicmore » index and bulge-to-total light ratio (B/T), confirming earlier results. Here, we describe the preparations of input data done for decompositions, give examples of our decomposition strategy, and describe the data products released via IRSA and via our web page (www.oulu.fi/astronomy/S4G-PIPELINE4/MAIN). These products include all the input data and decomposition files in electronic form, making it easy to extend the decompositions to suit specific science purposes. We also provide our IDL-based visualization tools (GALFIDL) developed for displaying/running GALFIT-decompositions, as well as our mask editing procedure (MASK-EDIT) used in data preparation. A detailed analysis of the bulge, disk, and bar parameters derived from multi-component decompositions will be published separately.« less

  12. A closer look at four-dot masking of a foveated target

    PubMed Central

    Wilson, Hugh R.

    2016-01-01

    Four-dot masking with a common onset mask was recently demonstrated in a fully attended and foveated target (Filmer, Mattingley & Dux, 2015). Here, we replicate and extend this finding by directly comparing a four-dot mask with an annulus mask while probing masking as a function of mask duration, and target-mask separation. Our results suggest that while an annulus mask operates via spatially local contour interactions, a four-dot mask operates through spatially global mechanisms. We also measure how the visual system’s representation of an oriented bar is impacted by a four-dot mask, and find that masking here does not degrade the precision of perceived targets, but instead appears to be driven exclusively by rendering the target completely invisible. PMID:27280073

  13. Force-dependent static dead space of face masks used with holding chambers.

    PubMed

    Shah, Samir A; Berlinski, Ariel B; Rubin, Bruce K

    2006-02-01

    Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.

  14. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    PubMed

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  15. Evaluation of the impact of the 2012 Rhode Island health care worker influenza vaccination regulations: implementation process and vaccination coverage.

    PubMed

    Kim, Hanna; Lindley, Megan C; Dube, Donna; Kalayil, Elizabeth J; Paiva, Kristi A; Raymond, Patricia

    2015-01-01

    In October 2012, the Rhode Island Department of Health (HEALTH) amended its health care worker (HCW) vaccination regulations to require all HCWs to receive annual influenza vaccination or wear a surgical mask during direct patient contact when influenza is widespread. Unvaccinated HCWs failing to wear a mask are subject to a fine and disciplinary action. To describe the implementation of the 2012 Rhode Island HCW influenza vaccination regulations and examine their impact on vaccination coverage. Two data sources were used: (1) a survey of all health care facilities subject to the HCW regulations and (2) HCW influenza vaccination coverage data reported to HEALTH by health care facilities. Descriptive statistics and paired t tests were performed using SAS Release 9.2. For the 2012-2013 influenza season, 271 inpatient and outpatient health care facilities in Rhode Island were subject to the HCW regulations. Increase in HCW influenza vaccination coverage. Of the 271 facilities, 117 facilities completed the survey (43.2%) and 160 facilities reported vaccination data to HEALTH (59.0%). Between the 2011-2012 and 2012-2013 influenza seasons, the proportion of facilities having a masking policy, as required by the revised regulations, increased from 9.4% to 94.0% (P < .001). However, the proportion of facilities implementing Advisory Committee on Immunization Practices-recommended strategies to promote HCW influenza vaccination did not increase. The majority of facilities perceived benefits to collecting HCW influenza vaccination data, including strengthening infection prevention efforts (83.2%) and improving patient and coworker safety (75.2%). Concurrent with the new regulations, influenza vaccination coverage among employee HCWs in Rhode Island increased from 69.7% in the 2011-2012 influenza season to 87.2% in the 2012-2013 season. Rhode Island's experience demonstrates that statewide HCW influenza vaccination requirements incorporating mask wearing and moderate penalties for noncompliance can be effective in improving influenza vaccination coverage among HCWs.

  16. Evaluation of the Impact of the 2012 Rhode Island Health Care Worker Influenza Vaccination Regulations: Implementation Process and Vaccination Coverage

    PubMed Central

    Kim, Hanna; Lindley, Megan C.; Dube, Donna; Kalayil, Elizabeth J.; Paiva, Kristi A.; Raymond, Patricia

    2015-01-01

    Context In October 2012, the Rhode Island Department of Health (HEALTH) amended its health care worker (HCW) vaccination regulations to require all HCWs to receive annual influenza vaccination or wear a surgical mask during direct patient contact when influenza is widespread. Unvaccinated HCWs failing to wear a mask are subject to a fine and disciplinary action. Objective To describe the implementation of the 2012 Rhode Island HCW influenza vaccination regulations and examine their impact on vaccination coverage. Design Two data sources were used: (1) a survey of all health care facilities subject to the HCW regulations and (2) HCW influenza vaccination coverage data reported to HEALTH by health care facilities. Descriptive statistics and paired t tests were performed using SAS Release 9.2. Setting and participants For the 2012-2013 influenza season, 271 inpatient and outpatient health care facilities in Rhode Island were subject to the HCW regulations. Main Outcome Measure Increase in HCW influenza vaccination coverage. Results Of the 271 facilities, 117 facilities completed the survey (43.2%) and 160 facilities reported vaccination data to HEALTH (59.0%). Between the 2011-2012 and 2012-2013 influenza seasons, the proportion of facilities having a masking policy, as required by the revised regulations, increased from 9.4% to 94.0% (P< .001). However, the proportion of facilities implementing Advisory Committee on Immunization Practices–recommended strategies to promote HCW influenza vaccination did not increase. The majority of facilities perceived benefits to collecting HCW influenza vaccination data, including strengthening infection prevention efforts (83.2%) and improving patient and coworker safety (75.2%). Concurrent with the new regulations, influenza vaccination coverage among employee HCWs in Rhode Island increased from 69.7% in the 2011-2012 influenza season to 87.2% in the 2012-2013 season. Conclusion Rhode Island's experience demonstrates that statewide HCW influenza vaccination requirements incorporating mask wearing and moderate penalties for noncompliance can be effective in improving influenza vaccination coverage among HCWs. PMID:25105280

  17. Quality assessment and improvement of the EUMETSAT Meteosat Surface Albedo Climate Data Record

    NASA Astrophysics Data System (ADS)

    Lattanzio, A.; Fell, F.; Bennartz, R.; Trigo, I. F.; Schulz, J.

    2015-10-01

    Surface albedo has been identified as an important parameter for understanding and quantifying the Earth's radiation budget. EUMETSAT generated the Meteosat Surface Albedo (MSA) Climate Data Record (CDR) currently comprising up to 24 years (1982-2006) of continuous surface albedo coverage for large areas of the Earth. This CDR has been created within the Sustained, Coordinated Processing of Environmental Satellite Data for Climate Monitoring (SCOPE-CM) framework. The long-term consistency of the MSA CDR is high and meets the Global Climate Observing System (GCOS) stability requirements for desert reference sites. The limitation in quality due to non-removed clouds by the embedded cloud screening procedure is the most relevant weakness in the retrieval process. A twofold strategy is applied to efficiently improve the cloud detection and removal. The first step consists of the application of a robust and reliable cloud mask, taking advantage of the information contained in the measurements of the infrared and visible bands. Due to the limited information available from old radiometers, some clouds can still remain undetected. A second step relies on a post-processing analysis of the albedo seasonal variation together with the usage of a background albedo map in order to detect and screen out such outliers. The usage of a reliable cloud mask has a double effect. It enhances the number of high-quality retrievals for tropical forest areas sensed under low view angles and removes the most frequently unrealistic retrievals on similar surfaces sensed under high view angles. As expected, the usage of a cloud mask has a negligible impact on desert areas where clear conditions dominate. The exploitation of the albedo seasonal variation for cloud removal has good potentialities but it needs to be carefully addressed. Nevertheless it is shown that the inclusion of cloud masking and removal strategy is a key point for the generation of the next MSA CDR release.

  18. Orientation tuning of contrast masking caused by motion streaks.

    PubMed

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  19. Effect of SPM-based cleaning POR on EUV mask performance

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Lee, Han-shin; Yoon, Jinsang; Shimomura, Takeya; Friz, Alex; Montgomery, Cecilia; Ma, Andy; Goodwin, Frank; Kang, Daehyuk; Chung, Paul; Shin, Inkyun; Cho, H.

    2011-11-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. The fact that a pellicle is not used to protect the mask surface in EUV lithography suggests that EUV masks may have to undergo more cleaning cycles during their lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality and patterning performance during 30 cycles of Samsung's EUV mask SPM-based cleaning and 20 cycles of SEMATECH ADT exposure. We have observed that the quality and patterning performance of EUV masks does not significantly change during these processes except mask pattern CD change. To resolve this issue, we have developed an acid-free cleaning POR and substantially improved EUV mask film loss compared to the SPM-based cleaning POR.

  20. Photoinitiator-free 3D scaffolds fabricated by excimer laser photocuring.

    PubMed

    Farkas, Balázs; Dante, Silvia; Brandi, Fernando

    2017-01-20

    Photoinitiator-free fabrication of poly(ethylene glycol) diacrylate (PEGDA) scaffolds is achieved using a novel three-dimensional (3D) printing method called mask projected excimer laser stereolithography (MPExSL). The spatial resolution of photoinitiator-free curing is suitable for 3D layer-by-layer fabrication with a single layer thickness well controllable at tens to hundreds of microns using 248 nm wavelength for the irradiation. The photoinitiator-free scaffolds are superior compared to their counterparts fabricated by using photoinitiator molecules, showing a higher level of biocompatibility. A release of toxic chemicals from the photoinitiator containing scaffolds is proven by cell proliferation tests. In contrast, no toxic release is found from the photoinitiator-free scaffolds, resulting in the very same level of cell proliferation as the control sample. The demonstration of photoinitiator-free PEGDA scaffolds enables the fabrication of 3D scaffolds with the highest level of biocompatibility for both in vitro and in vivo applications.

  1. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.

    PubMed

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-04-22

    The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Clay Mask Workshop

    ERIC Educational Resources Information Center

    Gamble, David L.

    2012-01-01

    Masks can represent so many things, such as emotions (happy, sad, fearful) and power. The familiar "comedy and tragedy" masks, derived from ancient Greek theater, are just one example from mask history. Death masks from the ancient Egyptians influenced the ancient Romans into creating similar masks for their departed. Masks can represent many…

  3. Extension of optical lithography by mask-litho integration with computational lithography

    NASA Astrophysics Data System (ADS)

    Takigawa, T.; Gronlund, K.; Wiley, J.

    2010-05-01

    Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.

  4. venice: Mask utility

    NASA Astrophysics Data System (ADS)

    Coupon, Jean

    2018-02-01

    venice reads a mask file (DS9 or fits type) and a catalogue of objects (ascii or fits type) to create a pixelized mask, find objects inside/outside a mask, or generate a random catalogue of objects inside/outside a mask. The program reads the mask file and checks if a point, giving its coordinates, is inside or outside the mask, i.e. inside or outside at least one polygon of the mask.

  5. Metacontrast masking is processed before grapheme-color synesthesia.

    PubMed

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  6. Pattern masking: the importance of remote spatial frequencies and their phase alignment.

    PubMed

    Huang, Pi-Chun; Maehara, Goro; May, Keith A; Hess, Robert F

    2012-02-16

    To assess the effects of spatial frequency and phase alignment of mask components in pattern masking, target threshold vs. mask contrast (TvC) functions for a sine-wave grating (S) target were measured for five types of mask: a sine-wave grating (S), a square-wave grating (Q), a missing fundamental square-wave grating (M), harmonic complexes consisting of phase-scrambled harmonics of a square wave (Qp), and harmonic complexes consisting of phase-scrambled harmonics of a missing fundamental square wave (Mp). Target and masks had the same fundamental frequency (0.46 cpd) and the target was added in phase with the fundamental frequency component of the mask. Under monocular viewing conditions, the strength of masking depends on phase relationships among mask spatial frequencies far removed from that of the target, at least 3 times the target frequency, only when there are common target and mask spatial frequencies. Under dichoptic viewing conditions, S and Q masks produced similar masking to each other and the phase-scrambled masks (Qp and Mp) produced less masking. The results suggest that pattern masking is spatial frequency broadband in nature and sensitive to the phase alignments of spatial components.

  7. Optimal mask characterization by Surrogate Wafer Print (SWaP) method

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hoellein, Ingo; Peters, Jan Hendrick; Ackmann, Paul; Connolly, Brid; West, Craig

    2008-10-01

    Traditionally, definition of mask specifications is done completely by the mask user, while characterization of the mask relative to the specifications is done completely by the mask maker. As the challenges of low-k1 imaging continue to grow in scope of designs and in absolute complexity, the inevitable partnership between wafer lithographers and mask makers has strengthened as well. This is reflected in the jointly owned mask facilities and device manufacturers' continued maintenance of fully captive mask shops which foster the closer mask-litho relationships. However, while some device manufacturers have leveraged this to optimize mask specifications before the mask is built and, therefore, improve mask yield and cost, the opportunity for post-fabrication partnering on mask characterization is more apparent and compelling. The Advanced Mask Technology Center (AMTC) has been investigating the concept of assessing how a mask images, rather than the mask's physical attributes, as a technically superior and lower-cost method to characterize a mask. The idea of printing a mask under its intended imaging conditions, then characterizing the imaged wafer as a surrogate for traditional mask inspections and measurements represents the ultimate method to characterize a mask's performance, which is most meaningful to the user. Surrogate wafer print (SWaP) is already done as part of leading-edge wafer fab mask qualification to validate defect and dimensional performance. In the past, the prospect of executing this concept has generally been summarily discarded as technically untenable and logistically intractable. The AMTC published a paper at BACUS 2007 successfully demonstrating the performance of SWaP for the characterization of defects as an alternative to traditional mask inspection [1]. It showed that this concept is not only feasible, but, in some cases, desirable. This paper expands on last year's work at AMTC to assess the full implementation of SWaP as an enhancement to mask characterization quality including defectivity, dimensional control, pattern fidelity, and in-plane distortion. We present a thorough analysis of both the technical and logistical challenges coupled with an objective view of the advantages and disadvantages from both the technical and financial perspectives. The analysis and model used by the AMTC will serve to provoke other mask shops to prepare their own analyses then consider this new paradigm for mask characterization and qualification.

  8. Clean induced feature CD shift of EUV mask

    NASA Astrophysics Data System (ADS)

    Nesládek, Pavel; Schedel, Thorsten; Bender, Markus

    2016-05-01

    EUV developed in the last decade to the most promising <7nm technology candidate. Defects are considered to be one of the most critical issues of the EUV mask. There are several contributors which make the EUV mask so different from the optical one. First one is the significantly more complicated mask stack consisting currently of 40 Mo/Si double layers, covered by Ru capping layer and TaN/TaO absorber/anti-reflective coating on top of the front face of the mask. Backside is in contrary to optical mask covered as well by conductive layer consisting of Cr or CrN. Second contributor is the fact that EUV mask is currently in contrary to optical mask not yet equipped with sealed pellicle, leading to much higher risk of mask contamination. Third reason is use of EUV mask in vacuum, possibly leading to deposition of vacuum contaminants on the EUV mask surface. Latter reason in combination with tight requirements on backside cleanliness lead to the request of frequent recleaning of the EUV mask, in order to sustain mask lifetime similar to that of optical mask. Mask cleaning process alters slightly the surface of any mask - binary COG mask, as well as phase shift mask of any type and naturally also of the EUV mask as well. In case of optical masks the changes are almost negligible, as the mask is exposed to max. 10-20 re-cleans within its life time. These modifications can be expressed in terms of different specified parameters, e.g. CD shift, phase/trans shift, change of the surface roughness etc. The CD shift, expressed as thinning (or exceptionally thickening) of the dark features on the mask is typically in order of magnitude 0.1nm per process run, which is completely acceptable for optical mask. Projected on the lifetime of EUV mask, assuming 100 clean process cycles, this will lead to CD change of about 10nm. For this reason the requirements for EUV mask cleaning are significantly tighter, << 0.1 nm per process run. This task will look even more challenging, when considering, that the tools for CD measurement at the EUV mask are identical as for optical mask. There is one aspect influencing the CD shift, which demands attention. The mask composition of the EUV mask is significantly different from the optical mask. More precisely there are 2 materials influencing the estimated CD in case of EUV mask, whereas there is one material only in case of optical masks, in first approximation. For optical masks, the CD changes can be attributed to modification of the absorber/ARC layer, as the quartz substrate can be hardly modified by the wet process. For EUV Masks chemical modification of the Ru capping layer - thinning, oxidization etc. are rather more probable and we need to take into account, how this effects can influence the CD measurement process. CD changes measured can be interpreted as either change in the feature size, or modification of the chemical nature of both absorber/ARC layer stack and the Ru capping layer. In our work we try to separate the effect of absorber and Ru/capping layer on the CD shift observed and propose independent way of estimation both parameters.

  9. Object Substitution Masking: When Does Mask Preview Work?

    ERIC Educational Resources Information Center

    Lim, Stephen Wee Hun; Chua, Fook K.

    2008-01-01

    When a target is enclosed by a 4-dot mask that persists after the target disappears, target identification is worse than it is when the mask terminates with the target. This masking effect is attributed to object substitution masking (OSM). Previewing the mask, however, attenuates OSM. This study investigated specific conditions under which mask…

  10. Comparison of face masks in the bag-mask ventilation of a manikin.

    PubMed

    Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S

    2006-02-01

    We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

  11. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  12. Evaluation of setup uncertainties for single-fraction SRS by comparing two different mask-creation methods

    NASA Astrophysics Data System (ADS)

    Baek, Jong Geun; Jang, Hyun Soo; Oh, Young Kee; Lee, Hyun Jeong; Kim, Eng Chan

    2015-07-01

    The purpose of this study was to evaluate the setup uncertainties for single-fraction stereotactic radiosurgery (SF-SRS) based on clinical data with two different mask-creation methods using pretreatment con-beam computed tomography imaging guidance. Dedicated frameless fixation Brain- LAB masks for 23 patients were created as a routine mask (R-mask) making method, as explained in the BrainLAB's user manual. Alternative masks (A-masks), which were created by modifying the cover range of the R-masks for the patient's head, were used for 23 patients. The systematic errors including these for each mask and stereotactic target localizer were analyzed, and the errors were calculated as the means ± standard deviations (SD) from the left-right (LR), superior-inferior (SI), anterior-posterior (AP), and yaw setup corrections. In addition, the frequencies of the threedimensional (3D) vector length were analyzed. The values of the mean setup corrections for the R-mask in all directions were < 0.7 mm and < 0.1°, whereas the magnitudes of the SDs were relatively large compared to the mean values. In contrast, the means and SDs of the A-mask were smaller than those for the R-mask with the exception of the SD in the AP direction. The means and SDs in the yaw rotational direction for the R-mask and the A-mask system were comparable. 3D vector shifts of larger magnitude occurred more frequently for the R-mask than the A-mask. The setup uncertainties for each mask with the stereotactic localizing system had an asymmetric offset towards the positive AP direction. The A-mask-creation method, which is capable of covering the top of the patient's head, is superior to that for the R-mask, so the use of the A-mask is encouraged for SF-SRS to reduce the setup uncertainties. Moreover, careful mask-making is required to prevent possible setup uncertainties.

  13. Pressure Ulcer Incidence in Patients Wearing Nasal-Oral Versus Full-Face Noninvasive Ventilation Masks.

    PubMed

    Schallom, Marilyn; Cracchiolo, Lisa; Falker, Antoinette; Foster, Jennifer; Hager, JoAnn; Morehouse, Tamara; Watts, Peggy; Weems, Linda; Kollef, Marin

    2015-07-01

    Device-related pressure ulcers from noninvasive ventilation masks alter skin integrity and cause patients discomfort. To examine the incidence, location, and stage of pressure ulcers and patients' comfort with a nasal-oral mask compared with a full-face mask. A before-after study of a convenience sample of patients with noninvasive ventilation orders in 5 intensive care units was conducted. Two groups of 100 patients each received either the nasal-oral mask or the full-face mask. Skin was assessed before the mask was applied and every 12 hours after that or upon mask removal. Comfort levels were assessed every 12 hours on a Likert scale of 1 to 5 (1, most comfortable). A pressure ulcer developed in 20% of patients in the nasal-oral mask group and 2% of patients in the full-face mask group (P < .001). Comfort scores were significantly lower (more comfortable) with the full-face mask (mean [SD], 1.9 [1.1]) than with the nasal-oral mask (mean [SD], 2.7 [1.2], P < .001). Neither mean hours worn nor percentage adherence differed significantly: 28.9 (SD, 27.2) hours and 92% for full-face mask and 25 (SD, 20.7) and 92% for nasal-oral mask. No patients who had a pressure ulcer develop with the nasal-oral mask had a pressure ulcer develop with the full-face mask. The full-face mask resulted in significantly fewer pressure ulcers and was more comfortable for patients. The full-face mask is a reasonable alternative to traditional nasal-oral masks for patients receiving noninvasive ventilation. ©2015 American Association of Critical-Care Nurses.

  14. Design Architecture of field-effect transistor with back gate electrode for biosensor application

    NASA Astrophysics Data System (ADS)

    Fathil, M. F. M.; Arshad, M. K. Md.; Hashim, U.; Ruslinda, A. R.; Gopinath, Subash C. B.; M. Nuzaihan M., N.; Ayub, R. M.; Adzhri, R.; Zaki, M.; Azman, A. H.

    2016-07-01

    This paper presents the preparation method of photolithography chrome mask design used in fabrication process of field-effect transistor with back gate biasing based biosensor. Initially, the chrome masks are designed by studying the process flow of the biosensor fabrication, followed by drawing of the actual chrome mask using the AutoCAD software. The overall width and length of the device is optimized at 16 mm and 16 mm, respectively. Fabrication processes of the biosensor required five chrome masks, which included source and drain formation mask, the back gate area formation mask, electrode formation mask, front gate area formation mask, and passivation area formation mask. The complete chrome masks design will be sent for chrome mask fabrication and for future use in biosensor fabrication.

  15. X-ray mask fabrication advancements at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-05-01

    The Microlithographic Mask Development Center (MMD) was established as the X-ray mask manufacturing facility at the IBM Microelectronics Division semiconductor fabricator in Essex Junction, Vermont. This center, in operation for over two years, produces high yielding, defect-free X-ray masks for competitive logic and memory products at 250nm groundrules and below. The MMD is a complete mask facility that manufactures silicon membrane mask blanks in the NIST format and finished masks with electroplated gold X-ray absorber. Mask patterning, with dimensions as small as 180 nm, is accomplished using IBM-built variable shaped spot e-beam systems. Masks are routinely inspected and repaired using state-of-the-art equipment: two KLA SEM Specs for defect inspection, a Leica LMS 2000 for image placement characterization, an Amray 2040c for image dimension characterization and a Micrion 8000 XMR for defect repair. This facility maintains a baseline mask process with daily production of 250nm, 32Mb SRAM line monitor masks for the continuous improvement of mask quality and processes. Development masks are produced for several semiconductor manufacturers including IBM, Motorola, Loral, and Sanders. Masks for 64Mb and 256Mb DRAM (IBM) and advanced logic/SRAM (IBM and Motorola) designs have also been delivered. This paper describes the MMD facility and its technical capabilities. Key manufacturing metrics such as mask turnaround time, parametric yield learning and defect reduction activities are highlighted. The challenges associated with improved mask quality, sub-180nm mask fabrication, and the transition to refractory metal absorber are discussed.

  16. Flavored Anesthetic Masks for Inhalational Induction in Children.

    PubMed

    Gupta, Aakriti; Mathew, Preethy Joseph; Bhardwaj, Neerja

    2017-10-01

    To evaluate the clinical efficacy of masking the odor of inhalational agents using fruit flavors on the anxiety behavior and compliance of children for inhalational induction. A prospective randomized double blind, placebo controlled study was conducted on 60 unpremedicated children in the age group of 4-12 y. Thirty children received anesthetic masks smeared with a flavor of child's choice while the other 30 children were induced using masks without flavor. Anxiety was assessed using modified Yale Pre-operative Anxiety Scale (mYPAS) in the pre-op room and during inhalational induction. Mask acceptance was graded by Induction Compliance Checklist (ICC). The cost-effectiveness of flavored anesthetic masks was compared to that of commercially available pre-scented masks. The baseline anxiety in the two groups was comparable. The number of children demonstrating high levels of anxiety at anesthetic induction was similar in flavored and non-flavored mask groups (p 0.45). The compliance to mask induction was also equally good (p 0.99). The authors found significant difference in the cost of flavored mask (INR 56.45 per mask) as compared to commercially available pre-scented masks (INR 660 per mask). The authors observed a placebo effect that reduced the pre-op anxiety in the control group which probably made the quality of induction equivalent with flavored and non-flavored masks. Therefore, using a flavored anesthetic mask is cost-effective than using a commercially available pre-scented mask.

  17. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    PubMed

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; P<.001). The intraoral mask resulted in greater received minute volume received compared with conventional cuffed face mask during ventilation with a 1-handed mask seal in a cadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  18. Using neuronal populations to study the mechanisms underlying spatial and feature attention

    PubMed Central

    Cohen, Marlene R.; Maunsell, John H.R.

    2012-01-01

    Summary Visual attention affects both perception and neuronal responses. Whether the same neuronal mechanisms mediate spatial attention, which improves perception of attended locations, and non-spatial forms of attention has been a subject of considerable debate. Spatial and feature attention have similar effects on individual neurons. Because visual cortex is retinotopically organized, however, spatial attention can co-modulate local neuronal populations, while feature attention generally requires more selective modulation. We compared the effects of feature and spatial attention on local and spatially separated populations by recording simultaneously from dozens of neurons in both hemispheres of V4. Feature and spatial attention affect the activity of local populations similarly, modulating both firing rates and correlations between pairs of nearby neurons. However, while spatial attention appears to act on local populations, feature attention is coordinated across hemispheres. Our results are consistent with a unified attentional mechanism that can modulate the responses of arbitrary subgroups of neurons. PMID:21689604

  19. Experimental demonstration of localized Brillouin gratings with low off-peak reflectivity established by perfect Golomb codes.

    PubMed

    Antman, Yair; Yaron, Lior; Langer, Tomi; Tur, Moshe; Levanon, Nadav; Zadok, Avi

    2013-11-15

    Dynamic Brillouin gratings (DBGs), inscribed by comodulating two writing pump waves with a perfect Golomb code, are demonstrated and characterized experimentally. Compared with pseudo-random bit sequence (PRBS) modulation of the pump waves, the Golomb code provides lower off-peak reflectivity due to the unique properties of its cyclic autocorrelation function. Golomb-coded DBGs allow the long variable delay of one-time probe waveforms with higher signal-to-noise ratios, and without averaging. As an example, the variable delay of return-to-zero, on-off keyed data at a 1 Gbit/s rate, by as much as 10 ns, is demonstrated successfully. The eye diagram of the reflected waveform remains open, whereas PRBS modulation of the pump waves results in a closed eye. The variable delay of data at 2.5 Gbit/s is reported as well, with a marginally open eye diagram. The experimental results are in good agreement with simulations.

  20. Robust transmission of rate coding in the inhibitory Purkinje cell to cerebellar nuclei pathway in awake mice

    PubMed Central

    Abbasi, Samira; Maran, Selva K.; Cao, Ying; Abbasi, Ataollah; Heck, Detlef H.

    2017-01-01

    Neural coding through inhibitory projection pathways remains poorly understood. We analyze the transmission properties of the Purkinje cell (PC) to cerebellar nucleus (CN) pathway in a modeling study using a data set recorded in awake mice containing respiratory rate modulation. We find that inhibitory transmission from tonically active PCs can transmit a behavioral rate code with high fidelity. We parameterized the required population code in PC activity and determined that 20% of PC inputs to a full compartmental CN neuron model need to be rate-comodulated for transmission of a rate code. Rate covariance in PC inputs also accounts for the high coefficient of variation in CN spike trains, while the balance between excitation and inhibition determines spike rate and local spike train variability. Overall, our modeling study can fully account for observed spike train properties of cerebellar output in awake mice, and strongly supports rate coding in the cerebellum. PMID:28617798

  1. Binaural sluggishness in the perception of tone sequences and speech in noise.

    PubMed

    Culling, J F; Colburn, H S

    2000-01-01

    The binaural system is well-known for its sluggish response to changes in the interaural parameters to which it is sensitive. Theories of binaural unmasking have suggested that detection of signals in noise is mediated by detection of differences in interaural correlation. If these theories are correct, improvements in the intelligibility of speech in favorable binaural conditions is most likely mediated by spectro-temporal variations in interaural correlation of the stimulus which mirror the spectro-temporal amplitude modulations of the speech. However, binaural sluggishness should limit the temporal resolution of the representation of speech recovered by this means. The present study tested this prediction in two ways. First, listeners' masked discrimination thresholds for ascending vs descending pure-tone arpeggios were measured as a function of rate of frequency change in the NoSo and NoSpi binaural configurations. Three-tone arpeggios were presented repeatedly and continuously for 1.6 s, masked by a 1.6-s burst of noise. In a two-interval task, listeners determined the interval in which the arpeggios were ascending. The results showed a binaural advantage of 12-14 dB for NoSpi at 3.3 arpeggios per s (arp/s), which reduced to 3-5 dB at 10.4 arp/s. This outcome confirmed that the discrimination of spectro-temporal patterns in noise is susceptible to the effects of binaural sluggishness. Second, listeners' masked speech-reception thresholds were measured in speech-shaped noise using speech which was 1, 1.5, and 2 times the original articulation rate. The articulation rate was increased using a phase-vocoder technique which increased all the modulation frequencies in the speech without altering its pitch. Speech-reception thresholds were, on average, 5.2 dB lower for the NoSpi than for the NoSo configuration, at the original articulation rate. This binaural masking release was reduced to 2.8 dB when the articulation rate was doubled, but the most notable effect was a 6-8 dB increase in thresholds with articulation rate for both configurations. These results suggest that higher modulation frequencies in masked signals cannot be temporally resolved by the binaural system, but that the useful modulation frequencies in speech are sufficiently low (<5 Hz) that they are invulnerable to the effects of binaural sluggishness, even at elevated articulation rates.

  2. A face versus non-face context influences amygdala responses to masked fearful eye whites.

    PubMed

    Kim, M Justin; Solomon, Kimberly M; Neta, Maital; Davis, F Caroline; Oler, Jonathan A; Mazzulla, Emily C; Whalen, Paul J

    2016-12-01

    The structure of the mask stimulus is crucial in backward masking studies and we recently demonstrated such an effect when masking faces. Specifically, we showed that activity of the amygdala is increased to fearful facial expressions masked with neutral faces and decreased to fearful expressions masked with a pattern mask-but critically both masked conditions discriminated fearful expressions from happy expressions. Given this finding, we sought to test whether masked fearful eye whites would produce a similar profile of amygdala response in a face vs non-face context. During functional magnetic resonance imaging scanning sessions, 30 participants viewed fearful or happy eye whites masked with either neutral faces or pattern images. Results indicated amygdala activity was increased to fearful vs happy eye whites in the face mask condition, but decreased to fearful vs happy eye whites in the pattern mask condition-effectively replicating and expanding our previous report. Our data support the idea that the amygdala is responsive to fearful eye whites, but that the nature of this activity observed in a backward masking design depends on the mask stimulus. © The Author (2016). Published by Oxford University Press.

  3. Masking with faces in central visual field under a variety of temporal schedules.

    PubMed

    Daar, Marwan; Wilson, Hugh R

    2015-11-01

    With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Wafer hot spot identification through advanced photomask characterization techniques: part 2

    NASA Astrophysics Data System (ADS)

    Choi, Yohan; Green, Michael; Cho, Young; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike

    2017-03-01

    Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for mask end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on sub-resolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. To overcome the limitation of 1D metrics, there are numerous on-going industry efforts to better define wafer-predictive metrics through both standard mask metrology and aerial CD methods. Even with these improvements, the industry continues to struggle to define useful correlative metrics that link the mask to final device performance. In part 1 of this work, we utilized advanced mask pattern characterization techniques to extract potential hot spots on the mask and link them, theoretically, to issues with final wafer performance. In this paper, part 2, we complete the work by verifying these techniques at wafer level. The test vehicle (TV) that was used for hot spot detection on the mask in part 1 will be used to expose wafers. The results will be used to verify the mask-level predictions. Finally, wafer performance with predicted and verified mask/wafer condition will be shown as the result of advanced mask characterization. The goal is to maximize mask end user yield through mask-wafer technology harmonization. This harmonization will provide the necessary feedback to determine optimum design, mask specifications, and mask-making conditions for optimal wafer process margin.

  5. Evaluation of a new pediatric positive airway pressure mask.

    PubMed

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged < 7 years was not available. This study evaluated apnea-hypopnea index (AHI) equivalence and acceptability of a new pediatric CPAP mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  6. Adaptation to different noninvasive ventilation masks in critically ill patients*

    PubMed Central

    da Silva, Renata Matos; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    OBJECTIVE: To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. METHODS: An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. RESULTS: We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. CONCLUSIONS: In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed. PMID:24068269

  7. Adaptation to different noninvasive ventilation masks in critically ill patients.

    PubMed

    Silva, Renata Matos da; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed.

  8. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and nasal pillow masks for the treatment of obstructive sleep apnea. J Clin Sleep Med 2016;12(9):1263–1268. PMID:27448430

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, Aaron P.; Carlson, Charles T.; Honan, Michael

    A plurality of masks is attached to the underside of a mask frame. This attachment is made such that each mask can independently move relative to the mask frame in three directions. This relative movement allows each mask to adjust its position to align with respective alignment pins disposed on a working surface. In one embodiment, each mask is attached to the mask frame using fasteners, where the fasteners have a shaft with a diameter smaller than the diameter of the mounting hole disposed on the mask. A bias element may be used to allow relative movement between the maskmore » and the mask frame in the vertical direction. Each mask may also have kinematic features to mate with the respective alignment pins on the working surface.« less

  10. Use of MODIS Satellite Data to Evaluate Juniperus spp. Pollen Phenology to Support a Pollen Dispersal Model, PREAM, to Support Public Health Allergy Alerts

    NASA Technical Reports Server (NTRS)

    Luvall, J. C.; Sprigg, W.; Levetin, E.; Huete, A.; Nickovic, S.; Pejanovic, G. A.; Vukovic, A.; VandeWater, P.; Budge, A.; Hudspeth, W.; hide

    2012-01-01

    Juniperus spp. pollen is a significant aeroallergen that can be transported 200-600 km from the source. Local observations of Juniperus spp. phenology may not be consistent with the timing and source of pollen collected by pollen sampling instruments. Methods: The Dust REgional Atmospheric Model (DREAM)is a verified model for atmospheric dust transport modeling using MODIS data products to identify source regions and quantities of dust. We successfully modified the DREAM model to incorporate pollen transport (PREAM) and used MODIS satellite images to develop Juniperus ashei pollen input source masks. The Pollen Release Potential Source Map, also referred to as a source mask in model applications, may use different satellite platforms and sensors and a variety of data sets other than the USGS GAP data we used to map J. ashei cover type. MODIS derived percent tree cover is obtained from MODIS Vegetation Continuous Fields (VCF) product (collection 3 and 4, MOD44B, 500 and 250 m grid resolution). We use updated 2010 values to calculate pollen concentration at source (J. ashei ). The original MODIS derived values are converted from native approx. 250 m to 990m (approx. 1 km) for the calculation of a mask to fit the model (PREAM) resolution. Results: The simulation period is chosen following the information that in the last 2 weeks of December 2010. The PREAM modeled near-surface concentrations (Nm-3) shows the transport patterns of J. ashei pollen over a 5 day period (Fig. 2). Typical scales of the simulated transport process are regional.

  11. Ebola Virus Glycoprotein Promotes Enhanced Viral Egress by Preventing Ebola VP40 From Associating With the Host Restriction Factor BST2/Tetherin.

    PubMed

    Gustin, Jean K; Bai, Ying; Moses, Ashlee V; Douglas, Janet L

    2015-10-01

    BST2/tetherin is an innate immune molecule with the unique ability to restrict the egress of human immunodeficiency virus (HIV) and other enveloped viruses, including Ebola virus (EBOV). Coincident with this discovery was the finding that the HIV Vpu protein down-regulates BST2 from the cell surface, thereby promoting viral release. Evidence suggests that the EBOV envelope glycoprotein (GP) also counteracts BST2, although the mechanism is unclear. We find that total levels of BST2 remain unchanged in the presence of GP, whereas surface BST2 is significantly reduced. GP is known to sterically mask surface receptors via its mucin domain. Our evaluation of mutant GP molecules indicate that masking of BST2 by GP is probably responsible for the apparent surface BST2 down-regulation; however, this masking does not explain the observed virus-like particle egress enhancement. We discovered that VP40 coimmunoprecipitates and colocalizes with BST2 in the absence but not in the presence of GP. These results suggest that GP may overcome the BST2 restriction by blocking an interaction between VP40 and BST2. Furthermore, we have observed that GP may enhance BST2 incorporation into virus-like particles. Understanding this novel EBOV immune evasion strategy will provide valuable insights into the pathogenicity of this deadly pathogen. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Masking Vegetable Bitterness to Improve Palatability Depends on Vegetable Type and Taste Phenotype

    PubMed Central

    2013-01-01

    Consumption of dark green vegetables falls short of recommendations, in part, because of unpleasant bitterness. A laboratory-based study of 37 adults was used to determine bitter and hedonic responses to vegetables (asparagus, Brussels sprouts, kale) with bitter masking agents (1.33 M sodium acetate, 10 and 32 mM sodium chloride, and 3.2 mM aspartame) and then characterized by taste phenotype and vegetable liking. In repeated-measures ANOVA, aspartame was most effective at suppressing bitterness and improving hedonic responses for all sampled vegetables. Among the sodium salts, 32 mM sodium chloride decreased bitterness for kale and sodium acetate reduced bitterness across all vegetables with a tendency to increase liking for Brussels sprouts, as release from mixture suppression increased perceived sweetness. Participants were nearly equally divided into three 6-n-propylthiouracil (PROP) phenotype groups. Those tasting the least PROP bitterness (non-tasters) reported least vegetable bitterness, and the additives produced little change in vegetable liking. Aspartame persisted as the most effective bitter blocker for the PROP tasters (medium, supertasters), improving vegetable liking for the medium tasters but too much sweetness for supertasters. The sodium salts showed some bitter blocking for PROP tasters, particularly sodium acetate, without significant gains in vegetable liking. Via a survey, adults characterized as low vegetable likers reported greater increase in vegetable liking with the maskers than did vegetable likers. These results suggest that bitter masking agents (mainly sweeteners) can suppress bitterness to increase acceptance if they are matched to perceived vegetable bitterness or to self-reported vegetable disliking. PMID:23682306

  13. Evaluation of a New Pediatric Positive Airway Pressure Mask

    PubMed Central

    Kushida, Clete A.; Halbower, Ann C.; Kryger, Meir H.; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J.; Mendoza, June

    2014-01-01

    Study Objectives: The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged < 7 years was not available. This study evaluated apnea-hypopnea index (AHI) equivalence and acceptability of a new pediatric CPAP mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Methods: Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. Results: AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. Conclusions: The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. Citation: Kushida CA, Halbower AC, Kryger MH, Pelayo R, Assalone V, Cardell CY, Huston S, Willes L, Wimms AJ, Mendoza J. Evaluation of a new pediatric positive airway pressure mask. J Clin Sleep Med 2014;10(9):979-984. PMID:25142768

  14. Coded mask telescopes for X-ray astronomy

    NASA Astrophysics Data System (ADS)

    Skinner, G. K.; Ponman, T. J.

    1987-04-01

    The principle of the coded mask techniques are discussed together with the methods of image reconstruction. The coded mask telescopes built at the University of Birmingham, including the SL 1501 coded mask X-ray telescope flown on the Skylark rocket and the Coded Mask Imaging Spectrometer (COMIS) projected for the Soviet space station Mir, are described. A diagram of a coded mask telescope and some designs for coded masks are included.

  15. Quantitative evaluation of manufacturability and performance for ILT produced mask shapes using a single-objective function

    NASA Astrophysics Data System (ADS)

    Choi, Heon; Wang, Wei-long; Kallingal, Chidam

    2015-03-01

    The continuous scaling of semiconductor devices is quickly outpacing the resolution improvements of lithographic exposure tools and processes. This one-sided progression has pushed optical lithography to its limits, resulting in the use of well-known techniques such as Sub-Resolution Assist Features (SRAF's), Source-Mask Optimization (SMO), and double-patterning, to name a few. These techniques, belonging to a larger category of Resolution Enhancement Techniques (RET), have extended the resolution capabilities of optical lithography at the cost of increasing mask complexity, and therefore cost. One such technique, called Inverse Lithography Technique (ILT), has attracted much attention for its ability to produce the best possible theoretical mask design. ILT treats the mask design process as an inverse problem, where the known transformation from mask to wafer is carried out backwards using a rigorous mathematical approach. One practical problem in the application of ILT is the resulting contour-like mask shapes that must be "Manhattanized" (composed of straight edges and 90-deg corners) in order to produce a manufacturable mask. This conversion process inherently degrades the mask quality as it is a departure from the "optimal mask" represented by the continuously curved shapes produced by ILT. However, simpler masks composed of longer straight edges reduce the mask cost as it lowers the shot count and saves mask writing time during mask fabrication, resulting in a conflict between manufacturability and performance for ILT produced masks1,2. In this study, various commonly used metrics will be combined into an objective function to produce a single number to quantitatively measure a particular ILT solution's ability to balance mask manufacturability and RET performance. Several metrics that relate to mask manufacturing costs (i.e. mask vertex count, ILT computation runtime) are appropriately weighted against metrics that represent RET capability (i.e. process-variation band, edge-placement-error) in order to reflect the desired practical balance. This well-defined scoring system allows direct comparison of several masks with varying degrees of complexities. Using this method, ILT masks produced with increasing mask constraints will be compared, and it will be demonstrated that using the smallest minimum width for mask shapes does not always produce the optimal solution.

  16. Contralateral Masking in Bilateral Cochlear Implant Patients: A Model of Medial Olivocochlear Function Loss

    PubMed Central

    Aronoff, Justin M.; Padilla, Monica; Fu, Qian-Jie; Landsberger, David M.

    2015-01-01

    Contralateral masking is the phenomenon where a masker presented to one ear affects the ability to detect a signal in the opposite ear. For normal hearing listeners, contralateral masking results in masking patterns that are both sharper and dramatically smaller in magnitude than ipsilateral masking. The goal of this study was to investigate whether medial olivocochlear (MOC) efferents are needed for the sharpness and relatively small magnitude of the contralateral masking function. To do this, bilateral cochlear implant patients were tested because, by directly stimulating the auditory nerve, cochlear implants circumvent the effects of the MOC efferents. The results indicated that, as with normal hearing listeners, the contralateral masking function was sharper than the ipsilateral masking function. However, although there was a reduction in the magnitude of the contralateral masking function compared to the ipsilateral masking function, it was relatively modest. This is in sharp contrast to the results of normal hearing listeners where the magnitude of the contralateral masking function is greatly reduced. These results suggest that MOC function may not play a large role in the sharpness of the contralateral masking function but may play a considerable role in the magnitude of the contralateral masking function. PMID:25798581

  17. Calibration of a Spatial-Temporal Discrimination Model from Forward, Simultaneous, and Backward Masking

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J.; Beard, B. L.; Stone, Leland (Technical Monitor)

    1997-01-01

    We have been developing a simplified spatial-temporal discrimination model similar to our simplified spatial model in that masking is assumed to be a function of the local visible contrast energy. The overall spatial-temporal sensitivity of the model is calibrated to predict the detectability of targets on a uniform background. To calibrate the spatial-temporal integration functions that define local visible contrast energy, spatial-temporal masking data are required. Observer thresholds were measured (2IFC) for the detection of a 12 msec target stimulus in the presence of a 700 msec mask. Targets were 1, 3 or 9 c/deg sine wave gratings. Masks were either one of these gratings or two of them combined. The target was presented in 17 temporal positions with respect to the mask, including positions before, during and after the mask. Peak masking was found near mask onset and offset for 1 and 3 c/deg targets, while masking effects were more nearly uniform during the mask for the 9 c/deg target. As in the purely spatial case, the simplified model can not predict all the details of masking as a function of masking component spatial frequencies, but overall the prediction errors are small.

  18. Anticipating and controlling mask costs within EDA physical design

    NASA Astrophysics Data System (ADS)

    Rieger, Michael L.; Mayhew, Jeffrey P.; Melvin, Lawrence S.; Lugg, Robert M.; Beale, Daniel F.

    2003-08-01

    For low k1 lithography, more aggressive OPC is being applied to critical layers, and the number of mask layers with OPC treatments is growing rapidly. The 130 nm, process node required, on average, 8 layers containing rules- or model-based OPC. The 90 nm node will have 16 OPC layers, of which 14 layers contain aggressive model-based OPC. This escalation of mask pattern complexity, coupled with the predominant use of vector-scan e-beam (VSB) mask writers contributes to the rising costs of advanced mask sets. Writing times for OPC layouts are several times longer than for traditional layouts, making mask exposure the single largest cost component for OPC masks. Lower mask yields, another key factor in higher mask costs, is also aggravated by OPC. Historical mask set costs are plotted below. The initial cost of a 90 nm-node mask set will exceed one million dollars. The relative impact of mask cost on chip depends on how many total wafers are printed with each mask set. For many foundry chips, where unit production is often well below 1000 wafers, mask costs are larger than wafer processing costs. Further increases in NRE may begin to discourage these suppliers' adoption to 90 nm and smaller nodes. In this paper we will outline several alternatives for reducing mask costs by strategically leveraging dimensional margins. Dimensional specifications for a particular masking layer usually are applied uniformly to all features on that layer. As a practical matter, accuracy requirements on different features in the design may vary widely. Take a polysilicon layer, for example: global tolerance specifications for that layer are driven by the transistor-gate requirements; but these parameters over-specify interconnect feature requirements. By identifying features where dimensional accuracy requirements can be reduced, additional margin can be leveraged to reduce OPC complexity. Mask writing time on VSB tools will drop in nearly direct proportion to reduce shot count. By inspecting masks with reference to feature-dependent margins, instead of uniform specifications, mask yield can be effectively increased further reducing delivered mask expense.

  19. Method for the fabrication of three-dimensional microstructures by deep X-ray lithography

    DOEpatents

    Sweatt, William C.; Christenson, Todd R.

    2005-04-05

    A method for the fabrication of three-dimensional microstructures by deep X-ray lithography (DXRL) comprises a masking process that uses a patterned mask with inclined mask holes and off-normal exposures with a DXRL beam aligned with the inclined mask holes. Microstructural features that are oriented in different directions can be obtained by using multiple off-normal exposures through additional mask holes having different orientations. Various methods can be used to block the non-aligned mask holes from the beam when using multiple exposures. A method for fabricating a precision 3D X-ray mask comprises forming an intermediate mask and a master mask on a common support membrane.

  20. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    PubMed

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  1. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    PubMed

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Effect of leaf digestion and artemisinin solubility for use in oral consumption of dried Artemisia annua leaves to treat malaria.

    PubMed

    Desrosiers, Matthew R; Weathers, Pamela J

    2016-08-22

    Artemisia annua L. produces the antimalarial sesquiterpene lactone, artemisinin (AN), and was traditionally used by the Chinese to treat fever, which was often caused by malaria. To measure effects of plant-based and dietary components on release of artemisinin and flavonoids from A. annua dried leaves (DLA) after simulated digestion. Simulated digestion was performed on DLA in four types of capsules, or in conjunction with protein, and protein-based foods: dry milk, casein, bovine serum albumin, peanuts, peanut butter, Plumpy'nut(®), and A. annua essential oils. Artemisinin and total flavonoids were measured in the liquid phase of the intestinal stage of digestion. After simulated digestion, peanuts and Plumpy'nut(®) lowered AN and flavonoids, respectively, recovered from the liquid digestate fraction. None of the compositions of the tested capsules altered AN or flavonoid release. Surprisingly, bovine serum albumin (BSA) increased both AN and flavonoids recovered from liquid simulated digestate fractions while casein had no effect. AN delivered as DLA was about 4 times more soluble in digestates than AN delivered as pure drug. Addition of a volume of essential oil equivalent to that found in a high essential oil producing A. annua cultivar also significantly increased AN solubility in simulated digestates. These results indicate encapsulating DLA may provide a way to mask the taste of A. annua without altering bioavailability. Similarly, many peanut-based products can be used to mask the flavor with appropriate dosing. Finally, the essential oil fraction of A. annua contributes to the increased AN solubility in DLA after simulated digestion. Our results suggest that use of DLA in the treatment of malaria and other artemisinin-susceptible diseases should be further tested in animals and humans. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. MODIS Data from the GES DISC DAAC: Moderate-Resolution Imaging Spectroradiometer (MODIS)

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Goddard Earth Sciences (GES) Distributed Active Archive Center (DAAC) is responsible for the distribution of the Level 1 data, and the higher levels of all Ocean and Atmosphere products (Land products are distributed through the Land Processes (LP) DAAC DAAC, and the Snow and Ice products are distributed though the National Snow and Ice Data Center (NSIDC) DAAC). Ocean products include sea surface temperature (SST), concentrations of chlorophyll, pigment and coccolithophores, fluorescence, absorptions, and primary productivity. Atmosphere products include aerosols, atmospheric water vapor, clouds and cloud masks, and atmospheric profiles from 20 layers. While most MODIS data products are archived in the Hierarchical Data Format-Earth Observing System (HDF-EOS 2.7) format, the ocean binned products and primary productivity products (Level 4) are in the native HDF4 format. MODIS Level 1 and 2 data are of the Swath type and are packaged in files representing five minutes of Files for Level 3 and 4 are global products at daily, weekly, monthly or yearly resolutions. Apart from the ocean binned and Level 4 products, these are in Grid type, and the maps are in the Cylindrical Equidistant projection with rectangular grid. Terra viewing (scenes of approximately 2000 by 2330 km). MODIS data have several levels of maturity. Most products are released with a provisional level of maturity and only announced as validated after rigorous testing by the MODIS Science Teams. MODIS/Terra Level 1, and all MODIS/Terra 11 micron SST products are announced as validated. At the time of this publication, the MODIS Data Support Team (MDST) is working with the Ocean Science Team toward announcing the validated status of the remainder of MODIS/Terra Ocean products. MODIS/Aqua Level 1 and cloud mask products are released with provisional maturity.

  4. Indinavir-loaded pH-sensitive microparticles for taste masking: toward extemporaneous pediatric anti-HIV/AIDS liquid formulations with improved patient compliance.

    PubMed

    Chiappetta, Diego A; Carcaboso, Angel M; Bregni, Carlos; Rubio, Modesto; Bramuglia, Guillermo; Sosnik, Alejandro

    2009-01-01

    The aim of this work was to develop indinavir pediatric anti-HIV/AIDS formulations enabling convenient dose adjustment, ease of oral administration, and improved organoleptic properties by means of the generation of drug-loaded microparticles made of a polymer that is insoluble under intake conditions and dissolves fast in the stomach in order to completely release the active agent. Indinavir-loaded microparticles made of a pH-dependent polymeric excipient soluble at pH < 5, Eudragit E100, were prepared using a double emulsion solvent diffusion technique and the in vitro release profiles characterized. Finally, taste masking properties were evaluated in blind randomized sensory experiments by ten healthy human volunteers. The use of a w/o/o emulsion system resulted in indinavir loads around 90%. Thermal analysis of the microparticles by differential scanning calorimetry revealed that indinavir appeared mainly dispersed at the molecular level. Concentrations of residual organic solvents as determined by gas chromatography were below the upper limits specified by the European Pharmacopeia for pharmaceutical oral formulations. Then, the behavior of drug-containing microparticles in aqueous media at different pH values was assessed. While they selectively dissolved in gastric-like medium, in tap water (intake conditions), the matrix remained almost unchanged and efficiently prevented drug dissolution. Finally, sensoring taste tests performed by volunteers indicated that systems with indinavir loads approximately 15% displayed acceptable taste. This work explored the production of indinavir-containing microparticles based on a common pharmaceutical excipient as a means for the improvement of medicines of drugs involved in the treatment of HIV/AIDS. For systems containing about 15% drug, taste studies confirmed the acceptability of the formulation. In pediatric regimes, this composition would require an acceptable amount of formulation (0.7-1.5 g).

  5. Effects of temporal integration on the shape of visual backward masking functions.

    PubMed

    Francis, Gregory; Cho, Yang Seok

    2008-10-01

    Many studies of cognition and perception use a visual mask to explore the dynamics of information processing of a target. Especially important in these applications is the time between the target and mask stimuli. A plot of some measure of target visibility against stimulus onset asynchrony is called a masking function, which can sometimes be monotonic increasing but other times is U-shaped. Theories of backward masking have long hypothesized that temporal integration of the target and mask influences properties of masking but have not connected the influence of integration with the shape of the masking function. With two experiments that vary the spatial properties of the target and mask, the authors provide evidence that temporal integration of the stimuli plays a critical role in determining the shape of the masking function. The resulting data both challenge current theories of backward masking and indicate what changes to the theories are needed to account for the new data. The authors further discuss the implication of the findings for uses of backward masking to explore other aspects of cognition.

  6. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    NASA Astrophysics Data System (ADS)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  7. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    PubMed

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  8. Development of movable mask system to cope with high beam current

    NASA Astrophysics Data System (ADS)

    Suetsugu, Y.; Shibata, K.; Sanami, T.; Kageyama, T.; Takeuchi, Y.

    2003-07-01

    The KEK B factory (KEKB), a high current electron-positron collider, has a movable mask (or collimator) system to reduce the background noise in the BELLE detector coming from spent particles. The early movable masks, however, had severe problems of heating, arcing, and vacuum leaks over the stored beam current of several hundred mA. The cause is intense trapped higher order modes (HOMs) excited at the mask head, where the cross section of the beam chamber changed drastically. The mask head, made of copper-tungsten alloy or pure copper, was frequently damaged by hitting of the high energy beam at the same time. Since the problems of the mask were revealed, several kinds of improved masks have been designed employing rf technologies in dealing with the HOM and installed to the ring step by step. Much progress has come from adopting a trapped-mode free structure, where the mask was a bent chamber itself. Recently the further improved mask with a reduced HOM design or HOM dampers was developed to suppress the heating of vacuum components near the mask due to the HOM traveling from the mask. To avoid damage to the mask head, on the other hand, a titanium mask head was tried. The latest masks are working as expected now at the stored beam current of 1.5 A. Presented are the problems and experiences on the movable mask system for the KEKB, which are characteristic of and common in a high intensity accelerator.

  9. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses.

    PubMed

    Zhou, S Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W; Suchmann, Donna B; Ijaz, M Khalid

    2018-03-01

    Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus ( S . aureus ), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S . aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM 2.5 ). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S . aureus ) were not significantly different. The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM 2.5 ) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM 2.5 and pathogens such as influenza and rhinoviruses.

  10. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses

    PubMed Central

    Zhou, S. Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W.; Suchmann, Donna B.

    2018-01-01

    Background Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. Methods The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus (S. aureus), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. Results The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S. aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM2.5). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S. aureus) were not significantly different. Conclusions The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM2.5) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM2.5 and pathogens such as influenza and rhinoviruses. PMID:29707364

  11. Film loss-free cleaning chemicals for EUV mask lifetime elongation developed through combinatorial chemical screening

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Kim, Jinsu; Lowe, Jeff; Dattilo, Davide; Koh, Soowan; Choi, Jun Yeol; Dietze, Uwe; Shoki, Tsutomu; Kim, Byung Gook; Jeon, Chan-Uk

    2015-10-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. SPM (Sulfuric acid peroxide mixture) which has been extensively used for acid cleaning of photomask and wafer has serious drawback for EUV mask cleaning. It shows severe film loss of tantalum-based absorber layers and limited removal efficiency of EUV-generated carbon contaminants on EUV mask surface. Here, we introduce such novel cleaning chemicals developed for EUV mask as almost film loss free for various layers of the mask and superior carbon removal performance. Combinatorial chemical screening methods allowed us to screen several hundred combinations of various chemistries and additives under several different process conditions of temperature and time, eventually leading to development of the best chemistry selections for EUV mask cleaning. Recently, there have been many activities for the development of EUV pellicle, driven by ASML and core EUV scanner customer companies. It is still important to obtain film-loss free cleaning chemicals because cleaning cycle of EUV mask should be much faster than that of optic mask mainly due to EUV pellicle lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality changes and film losses during 50 cleaning cycles using new chemicals as well as particle and carbon contaminant removal characteristics. We have observed that the performance of new chemicals developed is superior to current SPM or relevant cleaning chemicals for EUV mask cleaning and EUV mask lifetime elongation.

  12. Fabless company mask technology approach: fabless but not fab-careless

    NASA Astrophysics Data System (ADS)

    Hisamura, Toshiyuki; Wu, Xin

    2009-10-01

    There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer holds true. There is a need to be flexible enough on unrepairable defect at early stage but also a need for efficient risk management system on mask defect waivers. Mask defects are often waived in low design criticality area in favor of scrapping the mask and delaying the mask and wafer schedule. Xilinx's involvement in mask manufacturing has contributed significantly to our success in past many nodes and will continue.

  13. Overlay improvement by exposure map based mask registration optimization

    NASA Astrophysics Data System (ADS)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.

  14. Method for protecting chip corners in wet chemical etching of wafers

    DOEpatents

    Hui, Wing C.

    1994-01-01

    The present invention is a corner protection mask design that protects chip corners from undercutting during anisotropic etching of wafers. The corner protection masks abut the chip corner point and extend laterally from segments along one or both corner sides of the corner point, forming lateral extensions. The protection mask then extends from the lateral extensions, parallel to the direction of the corner side of the chip and parallel to scribe lines, thus conserving wafer space. Unmasked bomb regions strategically formed in the protection mask facilitate the break-up of the protection mask during etching. Corner protection masks are useful for chip patterns with deep grooves and either large or small chip mask areas. Auxiliary protection masks form nested concentric frames that etch from the center outward are useful for small chip mask patterns. The protection masks also form self-aligning chip mask areas. The present invention is advantageous for etching wafers with thin film windows, microfine and micromechanical structures, and for forming chip structures more elaborate than presently possible.

  15. Method for protecting chip corners in wet chemical etching of wafers

    DOEpatents

    Hui, W.C.

    1994-02-15

    The present invention is a corner protection mask design that protects chip corners from undercutting during anisotropic etching of wafers. The corner protection masks abut the chip corner point and extend laterally from segments along one or both corner sides of the corner point, forming lateral extensions. The protection mask then extends from the lateral extensions, parallel to the direction of the corner side of the chip and parallel to scribe lines, thus conserving wafer space. Unmasked bomb regions strategically formed in the protection mask facilitate the break-up of the protection mask during etching. Corner protection masks are useful for chip patterns with deep grooves and either large or small chip mask areas. Auxiliary protection masks form nested concentric frames that etch from the center outward are useful for small chip mask patterns. The protection masks also form self-aligning chip mask areas. The present invention is advantageous for etching wafers with thin film windows, microfine and micromechanical structures, and for forming chip structures more elaborate than presently possible. 63 figures.

  16. A graphene-based biosensing platform based on the release of DNA probes and rolling circle amplification.

    PubMed

    Liu, Meng; Song, Jinping; Shuang, Shaomin; Dong, Chuan; Brennan, John D; Li, Yingfu

    2014-06-24

    We report a versatile biosensing platform capable of achieving ultrasensitive detection of both small-molecule and macromolecular targets. The system features three components: reduced graphene oxide for its ability to adsorb single-stranded DNA molecules nonspecifically, DNA aptamers for their ability to bind reduced graphene oxide but undergo target-induced conformational changes that facilitate their release from the reduced graphene oxide surface, and rolling circle amplification (RCA) for its ability to amplify a primer-template recognition event into repetitive sequence units that can be easily detected. The key to the design is the tagging of a short primer to an aptamer sequence, which results in a small DNA probe that allows for both effective probe adsorption onto the reduced graphene oxide surface to mask the primer domain in the absence of the target, as well as efficient probe release in the presence of the target to make the primer available for template binding and RCA. We also made an observation that the circular template, which on its own does not cause a detectable level of probe release from the reduced graphene oxide, augments target-induced probe release. The synergistic release of DNA probes is interpreted to be a contributing factor for the high detection sensitivity. The broad utility of the platform is illustrated though engineering three different sensors that are capable of achieving ultrasensitive detection of a protein target, a DNA sequence and a small-molecule analyte. We envision that the approach described herein will find useful applications in the biological, medical, and environmental fields.

  17. The Dark Energy Survey First Data Release

    NASA Astrophysics Data System (ADS)

    Carrasco Kind, Matias

    2018-01-01

    In this talk I will announce and highlight the main components of the first public data release (DR1) coming from the Dark Energy Survey (DES).In January 2016, the DES survey made available, in a simple unofficial release to the astronomical community, the first set of products. This data was taken and studied during the DES Science Verification period consisting on roughly 250 sq. degrees and 25 million objects at a mean depth of i=23.7 that led to over 80 publications from DES scientist.The DR1 release is the first official release from the main survey and it consists on the observations taken during the first 3 seasons from August 2013 to February 2016 (about 100 nights each season) of the survey which cover the entire DES footprint. All of the Single Epoch Images and the Year 3 Coadded images distributed in 10223 tiles are available for download in this release. The catalogs provide astrometry, photometry and basic classification for near 400M objects in roughly 5000 sq. degrees on the southern hemisphere with a approximate mean depth of i=23.3. Complementary footprint, masking and depth information is also available. All of the software used during the generation of these products are open sourced and have been made available through the Github DES Organization. Images, data and other sub products have been possible through the international and collaborative effort of all 25 institutions involved in DES and are available for exploration and download through the interfaces provided by a partnership between NCSA, NOAO and LIneA.

  18. Object Substitution Masking Induced by Illusory Masks: Evidence for Higher Object-Level Locus of Interference

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Osaka, Naoyuki

    2009-01-01

    A briefly presented target can be rendered invisible by a lingering sparse mask that does not even touch it. This form of visual backward masking, called object substitution masking, is thought to occur at the object level of processing. However, it remains unclear whether object-level interference alone produces substitution masking because…

  19. Gestalt grouping and common onset masking.

    PubMed

    Kahan, Todd A; Mathis, Katherine M

    2002-11-01

    A four-dot mask that surrounds and is presented simultaneously with a briefly presented target will reduce a person's ability to identity that target if the mask persists beyond target offset and attention is divided (Enns & Di Lollo, 1997, 2000). This masking effect, referred to as common onset masking, reflects reentrant processing in the visual system and can best be explained with a theory of object substitution (Di Lollo, Enns, & Rensink, 2000). In the present experiments, we investigated whether Gestalt grouping variables would influence the strength of common onset masking. The results indicated that (1) masking was impervious to grouping by form, similarity of color, position, luminance polarity, and common region and (2) masking increased with the number of elements in the masking display.

  20. A computational investigation of feedforward and feedback processing in metacontrast backward masking

    PubMed Central

    Silverstein, David N.

    2015-01-01

    In human perception studies, visual backward masking has been used to understand the temporal dynamics of subliminal vs. conscious perception. When a brief target stimulus is followed by a masking stimulus after a short interval of <100 ms, performance on the target is impaired when the target and mask are in close spatial proximity. While the psychophysical properties of backward masking have been studied extensively, there is still debate on the underlying cortical dynamics. One prevailing theory suggests that the impairment of target performance due to the mask is the result of lateral inhibition between the target and mask in feedforward processing. Another prevailing theory suggests that this impairment is due to the interruption of feedback processing of the target by the mask. This computational study demonstrates that both aspects of these theories may be correct. Using a biophysical model of V1 and V2, visual processing was modeled as interacting neocortical attractors, which must propagate up the visual stream. If an activating target attractor in V1 is quiesced enough with lateral inhibition from a mask, or not reinforced by recurrent feedback, it is more likely to burn out before becoming fully active and progressing through V2 and beyond. Results are presented which simulate metacontrast backward masking with an increasing stimulus interval and with the presence and absence of feedback activity. This showed that recurrent feedback diminishes backward masking effects and can make conscious perception more likely. One model configuration presented a metacontrast noise mask in the same hypercolumns as the target, and produced type-A masking. A second model configuration presented a target line with two parallel adjacent masking lines, and produced type-B masking. Future work should examine how the model extends to more complex spatial mask configurations. PMID:25759672

  1. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    PubMed

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, P<0.01). The snap-fit mask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. What's behind the mask? A look at blood flow changes with prolonged facial pressure and expression using laser Doppler imaging.

    PubMed

    Van-Buendia, Lan B; Allely, Rebekah R; Lassiter, Ronald; Weinand, Christian; Jordan, Marion H; Jeng, James C

    2010-01-01

    Clinically, the initial blanching in burn scar seen on transparent plastic face mask application seems to diminish with time and movement requiring mask alteration. To date, studies quantifying perfusion with prolonged mask use do not exist. This study used laser Doppler imaging (LDI) to assess perfusion through the transparent face mask and movement in subjects with and without burn over time. Five subjects fitted with transparent face masks were scanned with the LDI on four occasions. The four subjects without burn were scanned in the following manner: 1) no mask, 2) mask on while at rest, 3) mask on with alternating intervals of sustained facial expression and rest, and 4) after mask removal. Images were acquired every 3 minutes throughout the 85-minute study period. The subject with burn underwent a shortened scanning protocol to increase comfort. Each face was divided into five regions of interest for analysis. Compared with baseline, mask application decreased perfusion significantly in all subjects (P < .0001). Perfusion did not change during the rest period. There were no significant differences with changing facial expression in any of the regions of interest. On mask removal, all regions of the face demonstrated a hyperemic effect with the chin (P = .05) and each cheek (P < .0001) reaching statistical significance. Perfusion levels did not return to baseline in the chin and cheeks after 30 minutes of mask removal. Perfusions remain constantly low while wearing the face mask, despite changing facial expressions. Changing facial expressions with the mask on did not alter perfusion. Hyperemic response occurs on removal of the mask. This study exposed methodology and statistical issues worth considering when conducting future research with the face, pressure therapy, and with LDI technology.

  3. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    PubMed Central

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477

  4. The effect of foveal and parafoveal masks on the eye movements of older and younger readers.

    PubMed

    Rayner, Keith; Yang, Jinmian; Schuett, Susanne; Slattery, Timothy J

    2014-06-01

    In the present study, we examined foveal and parafoveal processing in older compared with younger readers by using gaze-contingent paradigms with 4 conditions. Older and younger readers read sentences in which the text was either a) presented normally, b) the foveal word was masked as soon as it was fixated, c) all of the words to the left of the fixated word were masked, or d) all of the words to the right of the fixated word were masked. Although older and younger readers both found reading when the fixated word was masked quite difficult, the foveal mask increased sentence reading time more than 3-fold (3.4) for the older readers (in comparison with the control condition in which the sentence was presented normally) compared with the younger readers who took 1.3 times longer to read sentences in the foveal mask condition (in comparison with the control condition). The left and right parafoveal masks did not disrupt reading as severely as the foveal mask, though the right mask was more disruptive than the left mask. Also, there was some indication that the younger readers found the right mask condition relatively more disruptive than the left mask condition. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  5. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and... reduce the respiratory protective qualities of the gas mask. (c) Half-mask facepieces shall not interfere...

  6. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and... reduce the respiratory protective qualities of the gas mask. (c) Half-mask facepieces shall not interfere...

  7. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and... reduce the respiratory protective qualities of the gas mask. (c) Half-mask facepieces shall not interfere...

  8. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and... reduce the respiratory protective qualities of the gas mask. (c) Half-mask facepieces shall not interfere...

  9. 42 CFR 84.118 - Half-mask facepieces, full facepieces, and mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.118 Half-mask facepieces, full facepieces, and... reduce the respiratory protective qualities of the gas mask. (c) Half-mask facepieces shall not interfere...

  10. Individual differences in metacontrast masking regarding sensitivity and response bias.

    PubMed

    Albrecht, Thorsten; Mattler, Uwe

    2012-09-01

    In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Face mask use and control of respiratory virus transmission in households.

    PubMed

    MacIntyre, C Raina; Cauchemez, Simon; Dwyer, Dominic E; Seale, Holly; Cheung, Pamela; Browne, Gary; Fasher, Michael; Wood, James; Gao, Zhanhai; Booy, Robert; Ferguson, Neil

    2009-02-01

    Many countries are stockpiling face masks for use as a nonpharmaceutical intervention to control virus transmission during an influenza pandemic. We conducted a prospective cluster-randomized trial comparing surgical masks, non-fit-tested P2 masks, and no masks in prevention of influenza-like illness (ILI) in households. Mask use adherence was self-reported. During the 2006 and 2007 winter seasons, 286 exposed adults from 143 households who had been exposed to a child with clinical respiratory illness were recruited. We found that adherence to mask use significantly reduced the risk for ILI-associated infection, but <50% of participants wore masks most of the time. We concluded that household use of face masks is associated with low adherence and is ineffective for controlling seasonal respiratory disease. However, during a severe pandemic when use of face masks might be greater, pandemic transmission in households could be reduced.

  12. Masking of Figure-Ground Texture and Single Targets by Surround Inhibition: A Computational Spiking Model

    PubMed Central

    Supèr, Hans; Romeo, August

    2012-01-01

    A visual stimulus can be made invisible, i.e. masked, by the presentation of a second stimulus. In the sensory cortex, neural responses to a masked stimulus are suppressed, yet how this suppression comes about is still debated. Inhibitory models explain masking by asserting that the mask exerts an inhibitory influence on the responses of a neuron evoked by the target. However, other models argue that the masking interferes with recurrent or reentrant processing. Using computer modeling, we show that surround inhibition evoked by ON and OFF responses to the mask suppresses the responses to a briefly presented stimulus in forward and backward masking paradigms. Our model results resemble several previously described psychophysical and neurophysiological findings in perceptual masking experiments and are in line with earlier theoretical descriptions of masking. We suggest that precise spatiotemporal influence of surround inhibition is relevant for visual detection. PMID:22393370

  13. EUVL mask dual pods to be used for mask shipping and handling in exposure tools

    NASA Astrophysics Data System (ADS)

    Gomei, Yoshio; Ota, Kazuya; Lystad, John; Halbmair, Dave; He, Long

    2007-03-01

    The concept of Extreme Ultra-Violet Lithography (EUVL) mask dual pods is proposed for use in both mask shipping and handling in exposure tools. The inner pod was specially designed to protect masks from particle contamination during shipping from mask houses to wafer factories. It can be installed in a load-lock chamber of exposure tools and evacuated while holding the mask inside. The inner pod upper cover is removed just before the mask is installed to a mask stage. Prototypes were manufactured and tested for shipping and for vacuum cycling. We counted particle adders through these actions with a detectable level of 54 nm and up. The adder count was close to zero, or we can say that the obtained result is within the noise level of our present evaluation environment. This indicates that the present concept is highly feasible for EUVL mask shipping and handling in exposure tools.

  14. Rotating Modulation Imager for the Orphan Source Search Problem

    DTIC Science & Technology

    2008-01-01

    black mask. If the photon hits an open element it is transmitted and the function M(x) = 1. If the photon hits a closed mask element it is not...photon enters the top mask pair in the third slit, but passes through the second slit on the bottom mask. With a single black mask this is physically...modulation efficiency changes as a function of mask thickness for both tungsten and lead masks. The black line shows how the field of view changes with

  15. The spatial unmasking of speech: evidence for within-channel processing of interaural time delay.

    PubMed

    Edmonds, Barrie A; Culling, John F

    2005-05-01

    Across-frequency processing by common interaural time delay (ITD) in spatial unmasking was investigated by measuring speech reception thresholds (SRTs) for high- and low-frequency bands of target speech presented against concurrent speech or a noise masker. Experiment 1 indicated that presenting one of these target bands with an ITD of +500 micros and the other with zero ITD (like the masker) provided some release from masking, but full binaural advantage was only measured when both target bands were given an ITD of + 500 micros. Experiment 2 showed that full binaural advantage could also be achieved when the high- and low-frequency bands were presented with ITDs of equal but opposite magnitude (+/- 500 micros). In experiment 3, the masker was also split into high- and low-frequency bands with ITDs of equal but opposite magnitude (+/-500 micros). The ITD of the low-frequency target band matched that of the high-frequency masking band and vice versa. SRTs indicated that, as long as the target and masker differed in ITD within each frequency band, full binaural advantage could be achieved. These results suggest that the mechanism underlying spatial unmasking exploits differences in ITD independently within each frequency channel.

  16. 3D Printed "Starmix" Drug Loaded Dosage Forms for Paediatric Applications.

    PubMed

    Scoutaris, Nicolaos; Ross, Steven A; Douroumis, Dennis

    2018-01-16

    Three- dimensional (3D) printing has received significant attention as a manufacturing process for pharmaceutical dosage forms. In this study, we used Fusion Deposition Modelling (FDM) in order to print "candy - like" formulations by imitating Starmix® sweets to prepare paediatric medicines with enhanced palatability. Hot melt extrusion processing (HME) was coupled with FDM to prepare extruded filaments of indomethacin (IND), hypromellose acetate succinate (HPMCAS) and polyethylene glycol (PEG) formulations and subsequently feed them in the 3D printer. The shapes of the Starmix® objects were printed in the form of a heart, ring, bottle, ring, bear and lion. Differential scanning calorimetry (DSC), X-ray powder diffraction (XRPD), Fourier Transform Infra-red Spectroscopy (FT-IR) and confocal Raman analysis were used to assess the drug - excipient interactions and the content uniformity. Physicochemical analysis showed the presence of molecularly dispersed IND in the printed tablets. In vivo taste masking evaluation demonstrated excellent masking of the drug bitterness. The printed forms were evaluated for drug dissolution and showed immediate IND release independently of the printed shape, within 60 min. 3D printing was used successfully to process drug loaded filaments for the development of paediatric printed tablets in the form of Starmix® designs.

  17. Spectral and temporal changes to speech produced in the presence of energetic and informational maskers.

    PubMed

    Cooke, Martin; Lu, Youyi

    2010-10-01

    Talkers change the way they speak in noisy conditions. For energetic maskers, speech production changes are relatively well-understood, but less is known about how informational maskers such as competing speech affect speech production. The current study examines the effect of energetic and informational maskers on speech production by talkers speaking alone or in pairs. Talkers produced speech in quiet and in backgrounds of speech-shaped noise, speech-modulated noise, and competing speech. Relative to quiet, speech output level and fundamental frequency increased and spectral tilt flattened in proportion to the energetic masking capacity of the background. In response to modulated backgrounds, talkers were able to reduce substantially the degree of temporal overlap with the noise, with greater reduction for the competing speech background. Reduction in foreground-background overlap can be expected to lead to a release from both energetic and informational masking for listeners. Passive changes in speech rate, mean pause length or pause distribution cannot explain the overlap reduction, which appears instead to result from a purposeful process of listening while speaking. Talkers appear to monitor the background and exploit upcoming pauses, a strategy which is particularly effective for backgrounds containing intelligible speech.

  18. Assessing the extent and impact of the masking effect of disproportionality analyses on two spontaneous reporting systems databases.

    PubMed

    Maignen, Francois; Hauben, Manfred; Hung, Eric; Van Holle, Lionel; Dogne, Jean-Michel

    2014-02-01

    Masking is a statistical issue by which signals are hidden by the presence of other medicines in the database. In the absence algorithm, the impact of the masking effect has not been fully investigated. Our study is aimed at assessing the extent and the impact of the masking effect on two large spontaneous reporting databases. Cross sectional study using a set of terms of importance for public health in two spontaneous reporting databases. The analyses were performed on EudraVigilance (EV) and the Pfizer spontaneous reporting database (PfDB). Using the masking ratio, we have identified and removed the products inducing the highest masking effect. Studying a total of almost 50 000 drug-event combinations masking had an impact on approximately 60% of drug-event combinations were masked by another product with a masking ratio >1 in EV and 84% in PfDB. The prevalence of important masking was quite rare (0.003% of the DECs) and mainly affected events rarely reported in EV. The products involved in the highest masking effects are products known to induce the reaction. The removal of the masking effect of the highest masking product has revealed 974 signals of disproportionate reporting in EV including true signals. The study shows that the original ranking provided by the quantitative methods included in our study is marginally affected by the removal of the masking product. Our study suggests that significant masking is rare in large spontaneous databases and mostly affects events rarely reported in EV. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Analysis of the ability of catcher's masks to attenuate head accelerations on impact with a baseball.

    PubMed

    Shain, Kellen S; Madigan, Michael L; Rowson, Steven; Bisplinghoff, Jill; Duma, Stefan M

    2010-11-01

    The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. Research laboratory. None. Catcher's masks and impact velocity. The linear and angular head accelerations of the Hybrid III headform. Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.

  20. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.

    PubMed

    Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S

    2010-03-01

    To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.

  1. Asymmetry in Object Substitution Masking Occurs Relative to the Direction of Spatial Attention Shift

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Osaka, Naoyuki

    2010-01-01

    A sparse mask that persists beyond the duration of a target can reduce its visibility, a phenomenon called "object substitution masking". Y. Jiang and M. M. Chun (2001a) found an asymmetric pattern of substitution masking such that a mask on the peripheral side of the target caused stronger substitution masking than on the central side.…

  2. "The Mask Who Wasn't There": Visual Masking Effect with the Perceptual Absence of the Mask

    ERIC Educational Resources Information Center

    Rey, Amandine Eve; Riou, Benoit; Muller, Dominique; Dabic, Stéphanie; Versace, Rémy

    2015-01-01

    Does a visual mask need to be perceptually present to disrupt processing? In the present research, we proposed to explore the link between perceptual and memory mechanisms by demonstrating that a typical sensory phenomenon (visual masking) can be replicated at a memory level. Experiment 1 highlighted an interference effect of a visual mask on the…

  3. Mask etcher data strategy for 45nm and beyond

    NASA Astrophysics Data System (ADS)

    Lewington, Richard; Ibrahim, Ibrahim M.; Panayil, Sheeba; Kumar, Ajay; Yamartino, John

    2006-05-01

    Mask Etching for the 45nm technology node and beyond requires a system-level data and diagnostics strategy. This necessity stems from the need to control the performance of the mask etcher to increasingly stringent and diverse requirements of the mask production environment. Increasing mask costs and the capability to acquire and consolidate a wealth of data within the mask etch platform are primary motivators towards harnessing data mines for feedback into the mask etching optimization. There are offline and real-time possibilities and scenarios. Here, we discuss the data architecture, acquisition, and strategies of the Applied Materials Tetra II TM Mask Etch System.

  4. The efficacy of three different mask styles on a PAP titration night.

    PubMed

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Professional and Home-Made Face Masks Reduce Exposure to Respiratory Infections among the General Population

    PubMed Central

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-01-01

    Background Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. Methodology We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. Principal Findings All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Conclusions/Significance Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission. PMID:18612429

  6. Professional and home-made face masks reduce exposure to respiratory infections among the general population.

    PubMed

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-07-09

    Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission.

  7. Simulation-based MDP verification for leading-edge masks

    NASA Astrophysics Data System (ADS)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification acceptable.

  8. The Pan-STARRS1 Surveys

    NASA Astrophysics Data System (ADS)

    Chambers, Kenneth; Pan-STARRS Team

    2018-01-01

    The Pan-STARRS1 Surveys are complete and the first data release, DR1, is available from the Mikulski Archive for Space Telescopes (MAST) at the Space Telescope Science Institute. The data include a database of measured attributes of 3 billion objects, stacked images, and metadata of the 3pi Steradian Survey. The DR1 contains all stationary objects with mean and stack photometry registered on the GAIA astrometric frame. DR2 is in preparation and will be released this winter with all the individual epoch images and time domain photometry and forced photometry on the individual epoch images. The characteristics of the Pan-STARRS1 Surveys will be presented, including image quality, depth, cadence, and coverage. Measured attributes include PSF model magnitudes, aperture magnitudes, Kron Magnitudes, radial moments, Petrosian magnitudes, DeVaucoulers, Exponential, and Sersic magnitudes for extended objects. Images include total intensity, variance, and masks.An overview of the Pan-STARRS1 Surveys and data releases will be presented together with a brief description of the data collected since the end of the PS1 Science Consortium surveys, and the plans for the upcoming survey with PS1 and PS2 begining in February 2018.

  9. A conceptual approach to the masking effect of measures of disproportionality.

    PubMed

    Maignen, Francois; Hauben, Manfred; Hung, Eric; Holle, Lionel Van; Dogne, Jean-Michel

    2014-02-01

    Masking is a statistical issue by which true signals of disproportionate reporting are hidden by the presence of other products in the database. Masking is currently not perfectly understood. There is no algorithm to identify the potential masking drugs to remove them for subsequent analyses of disproportionality. The primary objective of our study is to develop a mathematical framework for assessing the extent and impact of the masking effect of measures of disproportionality. We have developed a masking ratio that quantifies the masking effect of a given product. We have conducted a simulation study to validate our algorithm. The masking ratio is a measure of the strength of the masking effect whether the analysis is performed at the report or event level, and the manner in which reports are allocated to cells in the contingency table significantly impact the masking mechanisms. The reports containing both the product of interest and the masking product need to be handled appropriately. The proposed algorithm can use simplified masking provided that underlying assumptions (in particular the size of the database) are verified. For any event, the strongest masking effect is associated with the drug with the highest number of records (reports excluding the product of interest). Our study provides significant insights with practical implications for real-world pharmacovigilance that are supported by both real and simulated data. The public health impact of masking is still unknown. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Alternating phase-shifted mask for logic gate levels, design, and mask manufacturing

    NASA Astrophysics Data System (ADS)

    Liebmann, Lars W.; Graur, Ioana C.; Leipold, William C.; Oberschmidt, James M.; O'Grady, David S.; Regaill, Denis

    1999-07-01

    While the benefits of alternating phase shifted masks in improving lithographic process windows at increased resolution are well known throughout the lithography community, broad implementation of this potentially powerful technique has been slow due to the inherent complexity of the layout design and mask manufacturing process. This paper will review a project undertaken at IBM's Semiconductor Research and Development Center and Mask Manufacturing and Development facility to understand the technical and logistical issues associated with the application of alternating phase shifted mask technology to the gate level of a full microprocessor chip. The work presented here depicts an important milestone toward integration of alternating phase shifted masks into the manufacturing process by demonstrating an automated design solution and yielding a functional alternating phase shifted mask. The design conversion of the microprocessor gate level to a conjugate twin shifter alternating phase shift layout was accomplished with IBM's internal design system that automatically scaled the design, added required phase regions, and resolved phase conflicts. The subsequent fabrication of a nearly defect free phase shifted mask, as verified by SEM based die to die inspection, highlights the maturity of the alternating phase shifted mask manufacturing process in IBM's internal mask facility. Well defined and recognized challenges in mask inspection and repair remain and the layout of alternating phase shifted masks present a design and data preparation overhead, but the data presented here demonstrate the feasibility of designing and building manufacturing quality alternating phase shifted masks for the gate level of a microprocessor.

  11. Marquardt's Phi mask: pitfalls of relying on fashion models and the golden ratio to describe a beautiful face.

    PubMed

    Holland, E

    2008-03-01

    Stephen Marquardt has derived a mask from the golden ratio that he claims represents the "ideal" facial archetype. Many have found his mask convincing, including cosmetic surgeons. However, Marquardt's mask is associated with numerous problems. The method used to examine goodness of fit with the proportions in the mask is faulty. The mask is ill-suited for non-European populations, especially sub-Saharan Africans and East Asians. The mask also appears to approximate the face shape of masculinized European women. Given that the general public strongly and overwhelmingly prefers above average facial femininity in women, white women seeking aesthetic facial surgery would be ill-advised to aim toward a better fit with Marquardt's mask. This article aims to show the proper way of assessing goodness of fit with Marquardt's mask, to address the shape of the mask as it pertains to masculinity-femininity, and to discuss the broader issue of an objective assessment of facial attractiveness. Generalized Procrustes analysis is used to show how goodness of fit with Marquardt's mask can be assessed. Thin-plate spline analysis is used to illustrate visually how sample faces, including northwestern European averages, differ from Marquardt's mask. Marquardt's mask best describes the facial proportions of masculinized white women as seen in fashion models. Marquardt's mask does not appear to describe "ideal" face shape even for white women because its proportions are inconsistent with the optimal preferences of most people, especially with regard to femininity.

  12. Reinforced Masks for Ion Plating of Solar Cells

    NASA Technical Reports Server (NTRS)

    Conley, W. R.; Swick, E. G.; Volkers, J. C.

    1987-01-01

    Proposed mask for ion plating of surface electrodes on silicon solar cells reinforced to hold shape better during handling. Fabrication process for improved mask similar to conventional mask. Additional cuts and bends made in wide diametral strip to form bridges between pairs of mask fingers facing each other across this strip. Bridges high enough not to act as masks so entire strip area plated.

  13. Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients

    PubMed Central

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425

  14. The difficult business model for mask equipment makers and mask infrastructure development support from consortia and governments

    NASA Astrophysics Data System (ADS)

    Hector, Scott

    2005-11-01

    The extension of optical projection lithography through immersion to patterning features with half pitch <=65 nm is placing greater demands on the mask. Strong resolution enhancement techniques (RETs), such as embedded and alternating phase shift masks and complex model-based optical proximity correction, are required to compensate for diffraction and limited depth of focus (DOF). To fabricate these masks, many new or upgraded tools are required to write patterns, measure feature sizes and placement, inspect for defects, review defect printability and repair defects on these masks. Beyond the significant technical challenges, suppliers of mask fabrication equipment face the challenge of being profitable in the small market for mask equipment while encountering significant R&D expenses to bring new generations of mask fabrication equipment to market. The total available market for patterned masks is estimated to be $2.5B to $2.9B per year. The patterned mask market is about 20% of the market size for lithography equipment and materials. The total available market for mask-making equipment is estimated to be about $800M per year. The largest R&D affordability issue arises for the makers of equipment for fabricating masks where total available sales are typically less than ten units per year. SEMATECH has used discounted cash flow models to predict the affordable R&D while maintaining industry accepted internal rates of return. The results have been compared to estimates of the total R&D cost to bring a new generation of mask equipment to market for various types of tools. The analysis revealed that affordability of the required R&D is a significant problem for many suppliers of mask-making equipment. Consortia such as SEMATECH and Selete have played an important role in cost sharing selected mask equipment and material development projects. Governments in the United States, in Europe and in Japan have also helped equipment suppliers with support for R&D. This paper summarizes the challenging business model for mask equipment suppliers and highlight government support for mask equipment and materials development.

  15. Barriers to mask wearing for influenza-like illnesses among urban Hispanic households.

    PubMed

    Ferng, Yu-hui; Wong-McLoughlin, Jennifer; Barrett, Angela; Currie, Leanne; Larson, Elaine

    2011-01-01

    To identify barriers to mask wearing and to examine the factors associated with the willingness to wear masks among households. We used data sources from a study assessing the impact of 3 nonpharmaceutical interventions on the rates of influenza: exit interviews; home visits with a subset of the mask group; and a focus group. Risk perception score, univariate analysis, and logistic regression were conducted to identify the characteristics and predictors of mask use. Thematic barriers to mask wearing were identified from qualitative data obtained at home visits and focus group. Respondents from the mask group, when compared with the nonmask group, demonstrated higher risk perception scores concerning influenza (maximum score: 60, means: 37.6 and 30.2, p<.001) and increased perception of effectiveness of mask wearing (maximum score: 10, means: 7.8 and 7.3, p=.043). There was no significant association between demographic, attitudinal, or knowledge variables and adherence to wearing masks. Thematic barriers were identified such as social acceptability of mask use, comfort and fit, and perception of the risk/need for masks. Face masks may not be an effective intervention for seasonal or pandemic influenza unless the risk perception of influenza is high. Dissemination of culturally appropriate mask use information by health authorities and providers must be emphasized when educating the public. © 2010 Wiley Periodicals, Inc.

  16. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    PubMed Central

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; p<0.001). With oronasal masks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  17. Performance and stability of mask process correction for EBM-7000

    NASA Astrophysics Data System (ADS)

    Saito, Yasuko; Chen, George; Wang, Jen-Shiang; Bai, Shufeng; Howell, Rafael; Li, Jiangwei; Tao, Jun; VanDenBroeke, Doug; Wiley, Jim; Takigawa, Tadahiro; Ohnishi, Takayuki; Kamikubo, Takashi; Hara, Shigehiro; Anze, Hirohito; Hattori, Yoshiaki; Tamamushi, Shuichi

    2010-05-01

    In order to support complex optical masks today and EUV masks in the near future, it is critical to correct mask patterning errors with a magnitude of up to 20nm over a range of 2000nm at mask scale caused by short range mask process proximity effects. A new mask process correction technology, MPC+, has been developed to achieve the target requirements for the next generation node. In this paper, the accuracy and throughput performance of MPC+ technology is evaluated using the most advanced mask writing tool, the EBM-70001), and high quality mask metrology . The accuracy of MPC+ is achieved by using a new comprehensive mask model. The results of through-pitch and through-linewidth linearity curves and error statistics for multiple pattern layouts (including both 1D and 2D patterns) are demonstrated and show post-correction accuracy of 2.34nm 3σ for through-pitch/through-linewidth linearity. Implementing faster mask model simulation and more efficient correction recipes; full mask area (100cm2) processing run time is less than 7 hours for 32nm half-pitch technology node. From these results, it can be concluded that MPC+ with its higher precision and speed is a practical technology for the 32nm node and future technology generations, including EUV, when used with advance mask writing processes like the EBM-7000.

  18. How color, regularity, and good Gestalt determine backward masking.

    PubMed

    Sayim, Bilge; Manassi, Mauro; Herzog, Michael

    2014-06-18

    The strength of visual backward masking depends on the stimulus onset asynchrony (SOA) between target and mask. Recently, it was shown that the conjoint spatial layout of target and mask is as crucial as SOA. Particularly, masking strength depends on whether target and mask group with each other. The same is true in crowding where the global spatial layout of the flankers and target-flanker grouping determine crowding strength. Here, we presented a vernier target followed by different flanker configurations at varying SOAs. Similar to crowding, masking of a red vernier target was strongly reduced for arrays of 10 green compared with 10 red flanking lines. Unlike crowding, single green lines flanking the red vernier showed strong masking. Irregularly arranged flanking lines yielded stronger masking than did regularly arranged lines, again similar to crowding. While cuboid flankers reduced crowding compared with single lines, this was not the case in masking. We propose that, first, masking is reduced when the flankers are part of a larger spatial structure. Second, spatial factors counteract color differences between the target and the flankers. Third, complex Gestalts, such as cuboids, seem to need longer processing times to show ungrouping effects as observed in crowding. Strong parallels between masking and crowding suggest similar underlying mechanism; however, temporal factors in masking additionally modulate performance, acting as an additional grouping cue. © 2014 ARVO.

  19. System for generating two-dimensional masks from a three-dimensional model using topological analysis

    DOEpatents

    Schiek, Richard [Albuquerque, NM

    2006-06-20

    A method of generating two-dimensional masks from a three-dimensional model comprises providing a three-dimensional model representing a micro-electro-mechanical structure for manufacture and a description of process mask requirements, reducing the three-dimensional model to a topological description of unique cross sections, and selecting candidate masks from the unique cross sections and the cross section topology. The method further can comprise reconciling the candidate masks based on the process mask requirements description to produce two-dimensional process masks.

  20. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

    PubMed

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-07-01

    Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Accredited laboratory in a university hospital. Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H(2)O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx

  1. Mask aligner for ultrahigh vacuum with capacitive distance control

    NASA Astrophysics Data System (ADS)

    Bhaskar, Priyamvada; Mathioudakis, Simon; Olschewski, Tim; Muckel, Florian; Bindel, Jan Raphael; Pratzer, Marco; Liebmann, Marcus; Morgenstern, Markus

    2018-04-01

    We present a mask aligner driven by three piezomotors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed at a μm distance from the sample surface, while keeping it parallel to the surface, without touching the sample by the mask a priori. Samples and masks can be exchanged in-situ and the mask can additionally be displaced parallel to the surface. We demonstrate an edge sharpness of the deposited structures below 100 nm, which is likely limited by the diffusion of the deposited Au on Si(111).

  2. "Slit Mask Design for the Giant Magellan Telescope Multi-object Astronomical and Cosmological Spectrograph"

    NASA Astrophysics Data System (ADS)

    Williams, Darius; Marshall, Jennifer L.; Schmidt, Luke M.; Prochaska, Travis; DePoy, Darren L.

    2018-01-01

    The Giant Magellan Telescope Multi-object Astronomical and Cosmological Spectrograph (GMACS) is currently in development for the Giant Magellan Telescope (GMT). GMACS will employ slit masks with a usable diameter of approximately 0.450 m for the purpose of multi-slit spectroscopy. Of significant importance are the design constraints and parameters of the multi-object slit masks themselves as well as the means for mapping astronomical targets to physical mask locations. Analytical methods are utilized to quantify deformation effects on a potential slit mask due to thermal expansion and vignetting of target light cones. Finite element analysis (FEA) is utilized to simulate mask flexure in changing gravity vectors. The alpha version of the mask creation program for GMACS, GMACS Mask Simulator (GMS), a derivative of the OSMOS Mask Simulator (OMS), is introduced.

  3. Respiratory Source Control Using Surgical Masks With Nanofiber Media

    PubMed Central

    Skaria, Shaji D.; Smaldone, Gerald C.

    2014-01-01

    Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728

  4. Respiratory source control using surgical masks with nanofiber media.

    PubMed

    Skaria, Shaji D; Smaldone, Gerald C

    2014-07-01

    Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Active membrane masks for improved overlay performance in proximity lithography

    NASA Astrophysics Data System (ADS)

    Huston, Dryver R.; Plumpton, James; Esser, Brian; Sullivan, Gerald A.

    2004-07-01

    Membrane masks are thin (2 micron x 35 mm x 35 mm) structures that carry the master exposure patterns in proximity (X-ray) lithography. With the continuous drive to the printing of ever-finer features in microelectronics, the reduction of mask-wafer overlay positioning errors by passive rigid body positioning and passive stress control in the mask becomes impractical due to nano and sub-micron scale elastic deformations in the membrane mask. This paper describes the design, mechanics and performance of a system for actively stretching a membrane mask in-plane to control overlay distortion. The method uses thermoelectric heating/cooling elements placed on the mask perimeter. The thermoelectric elements cause controlled thermoelastic deformations in the supporting wafer, which in turn corrects distortions in the membrane mask. Silicon carbide masks are the focus of this study, but the method is believed to be applicable to other mask materials, such as diamond. Experimental and numerical results will be presented, as well as a discussion of the design issues and related design decisions.

  6. Mask automation: need a revolution in mask makers and equipment industry

    NASA Astrophysics Data System (ADS)

    Moon, Seong-yong; Yu, Sang-yong; Noh, Young-hwa; Son, Ki-jung; Lee, Hyun-Joo; Cho, Han-Ku

    2013-09-01

    As improving device integration for the next generation, high performance and cost down are also required accordingly in semiconductor business. Recently, significant efforts have been given on putting EUV technology into fabrication in order to improve device integration. At the same time, 450mm wafer manufacturing environment has been considered seriously in many ways in order to boost up the productivity. Accordingly, 9-inch mask has been discussed in mask fabrication business recently to support 450mm wafer manufacturing environment successfully. Although introducing 9-inch mask can be crucial for mask industry, multi-beam technology is also expected as another influential turning point to overcome currently the most critical issue in mask industry, electron beam writing time. No matter whether 9-inch mask or multi-beam technology will be employed or not, mask quality and productivity will be the key factors to survive from the device competition. In this paper, the level of facility automation in mask industry is diagnosed and analyzed and the automation guideline is suggested for the next generation.

  7. Evaluation of CS (o-chlorobenzylidene malononitrile) concentrations during U.S. Army mask confidence training.

    PubMed

    Hout, Joseph J; Kluchinsky, Timothy; LaPuma, Peter T; White, Duvel W

    2011-10-01

    All soldiers in the U.S. Army are required to complete mask confidence training with o-chlorobenzylidene malononitrile (CS). To instill confidence in the protective capability of the military protective mask, CS is thermally dispersed in a room where soldiers wearing military protective masks are required to conduct various physical exercises, break the seal of their mask, speak, and remove their mask. Soldiers immediately feel the irritating effects of CS when the seal of the mask is broken, which reinforces the mask's ability to shield the soldier from airborne chemical hazards. In the study described in this article, the authors examined the CS concentration inside a mask confidence chamber operated in accordance with U.S. Army training guidelines. The daily average CS concentrations ranged from 2.33-3.29 mg/m3 and exceeded the threshold limit value ceiling, the recommended exposure limit ceiling, and the concentration deemed immediately dangerous to life and health. The minimum and maximum CS concentration used during mask confidence training should be evaluated.

  8. Modeling of thermomechanical changes of extreme-ultraviolet mask and their dependence on absorber variation

    NASA Astrophysics Data System (ADS)

    Ban, Chung-Hyun; Park, Eun-Sang; Park, Jae-Hun; Oh, Hye-Keun

    2018-06-01

    Thermal and structural deformation of extreme-ultraviolet lithography (EUVL) masks during the exposure process may become important issues as these masks are subject to rigorous image placement and flatness requirements. The reflective masks used for EUVL absorb energy during exposure, and the temperature of the masks rises as a result. This can cause thermomechanical deformation that can reduce the pattern quality. The use of very thick low-thermal-expansion substrate materials (LTEMs) may reduce energy absorption, but they do not completely eliminate mask deformation. Therefore, it is necessary to predict and optimize the effects of energy transferred from the extreme-ultraviolet (EUV) light source and the resultant patterns of structured EUV masks with complex multilayers. Our study shows that heat accumulates in the masks as exposure progresses. It has been found that a higher absorber ratio (pattern density) applied to the patterning of EUV masks exacerbates the problem, especially in masks with more complex patterns.

  9. Impact of input mask signals on delay-based photonic reservoir computing with semiconductor lasers.

    PubMed

    Kuriki, Yoma; Nakayama, Joma; Takano, Kosuke; Uchida, Atsushi

    2018-03-05

    We experimentally investigate delay-based photonic reservoir computing using semiconductor lasers with optical feedback and injection. We apply different types of temporal mask signals, such as digital, chaos, and colored-noise mask signals, as the weights between the input signal and the virtual nodes in the reservoir. We evaluate the performance of reservoir computing by using a time-series prediction task for the different mask signals. The chaos mask signal shows superior performance than that of the digital mask signals. However, similar prediction errors can be achieved for the chaos and colored-noise mask signals. Mask signals with larger amplitudes result in better performance for all mask signals in the range of the amplitude accessible in our experiment. The performance of reservoir computing is strongly dependent on the cut-off frequency of the colored-noise mask signals, which is related to the resonance of the relaxation oscillation frequency of the laser used as the reservoir.

  10. Increased dead space in face mask continuous positive airway pressure in neonates.

    PubMed

    Hishikawa, Kenji; Fujinaga, Hideshi; Ito, Yushi

    2017-01-01

    Continuous positive airway pressure (CPAP) by face mask is commonly performed in newborn resuscitation. We evaluated the effect of face mask CPAP on system dead space. Face mask CPAP increases dead space. A CPAP model study. We estimated the volume of the inner space of the mask. We devised a face mask CPAP model, in which the outlet of the mask was covered with plastic; and three modified face mask CPAP models, in which holes were drilled near to the cushion of the covered face mask to alter the air exit. We passed a continuous flow of 21% oxygen through each model and we controlled the inner pressure to 5 cmH 2 O by adjusting the flow-relief valve. To evaluate the ventilation in the inner space of each model, we measured the oxygen concentration rise time, that is, the time needed for the oxygen concentration of each model to reach 35% after the oxygen concentration of the continuous flow was raised from 21% to 40%. The volume of inner space of the face mask was 38.3 ml. Oxygen concentration rise time in the face mask CPAP model was significantly longer at various continuous flow rates and points of the inner space of the face mask compared with that of the modified face mask CPAP model. Our study indicates that face mask CPAP leads to an increase in dead space and a decrease in ventilation efficiency under certain circumstances. Pediatr Pulmonol. 2017;52:107-111. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Effects of hard mask etch on final topography of advanced phase shift masks

    NASA Astrophysics Data System (ADS)

    Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin

    2017-07-01

    Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.

  12. Optimizing defect inspection strategy through the use of design-aware database control layers

    NASA Astrophysics Data System (ADS)

    Stoler, Dvori; Ruch, Wayne; Ma, Weimin; Chakravarty, Swapnajit; Liu, Steven; Morgan, Ray; Valadez, John; Moore, Bill; Burns, John

    2007-10-01

    Resolution limitations in the mask making process can cause differences between the features that appear in a database and those printed to a reticle. These differences may result from intentional or unintentional features in the database exceeding the resolution limit of the mask making process such as small gaps or lines in the data, line end shortening on small sub-resolution assist features etc creating challenges to both mask writing and mask inspection. Areas with high variance from design to mask, often referred to as high MEEF areas (mask error enhancement factor), become highly problematic and can directly impact mask and device yield, mask manufacturing cycle time and ultimately mask costs. Specific to mask inspection it may be desirable to inspect certain non-critical or non-relevant features at reduced sensitivity so as not to detect real, but less significant process defects. In contrast there may also be times where increased sensitivity is required for critical mask features or areas. Until recently, this process was extremely manual, creating added time and cost to the mask inspection cycle. Shifting to more intelligent and automated inspection flows is the key focus of this paper. A novel approach to importing design data directly into the mask inspection to include both MDP generated MRC errors files and LRC generated MEEF files. The results of recently developed inspection and review capability based upon controlling defect inspection using design aware data base control layers on a pixel basis are discussed. Typical mask shop applications and implementations will be shown.

  13. Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

    PubMed Central

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-01-01

    Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H2O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx Citation: Teo M; Amis T; Lee S; Falland K; Lambert S; Wheatley J. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome. SLEEP 2011;34(7):951-955. PMID:21731145

  14. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    PubMed

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  15. Computerized Dead-Space Volume Measurement of Face Masks Applied to Simulated Faces.

    PubMed

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Marzuk, Chatib; Daitzchman, Marcelo; Newhouse, Michael T

    2015-09-01

    The dead-space volume (VD) of face masks for metered-dose inhaler treatments is particularly important in infants and young children with asthma, who have relatively low tidal volumes. Data about VD have been traditionally obtained from water displacement measurements, in which masks are held against a flat surface. Because, in real life, masks are placed against the face, VD is likely to differ considerably between masks depending upon their contour and fit. The aim of this study was to develop an accurate and reliable way to measure VD electronically and to apply this technique by comparing the electronic VD of commonly available face masks. Average digital faces were obtained from 3-dimensional images of 270 infants and children. Commonly used face masks (small and medium) from various manufacturers (Monaghan Medical, Pari Respiratory Equipment, Philips Respironics, and InspiRx) were scanned and digitized by means of computed tomography. Each mask was electronically applied to its respective digital face, and the VD enclosed (mL) was computerized and precisely measured. VD varied between 22.6 mL (SootherMask, InspiRx) and 43.1 mL (Vortex, Pari) for small masks and between 41.7 mL (SootherMask) and 71.5 mL (AeroChamber, Monaghan Medical) for medium masks. These values were significantly lower and less variable than measurements obtained by water displacement. Computerized techniques provide an innovative and relatively simple way of accurately measuring the VD of face masks applied to digital faces. As determined by computerized measurement using average-size virtual faces, the InspiRx masks had a significantly smaller VD for both small and medium masks compared with the other masks. This is of considerable importance with respect to aerosol dose and delivery time, particularly in young children. (ClinicalTrials.gov registration NCT01274299.). Copyright © 2015 by Daedalus Enterprises.

  16. Extraction and utilization of the repeating patterns for CP writing in mask making

    NASA Astrophysics Data System (ADS)

    Shoji, Masahiro; Inoue, Tadao; Yamabe, Masaki

    2010-05-01

    In May 2006, the Mask Design, Drawing, and Inspection Technology Research Department (Mask D2I) at the Association of Super-Advanced Electronics Technologies (ASET) launched a 4-year program for reducing mask manufacturing cost and TAT by concurrent optimization of Mask Data Preparation (MDP), mask writing, and mask inspection [1]. Figure 1 shows an outline of the project at Mask D2I at ASET. As one of the tasks being pursued at the Mask Design Data Technology Research Laboratory we have evaluated the effect of reducing the writing shot counts by utilizing the repeating patterns, and that showed positive impact on mask making by using CP writing. During the past four years, we have developed a software to extract repeating patterns from fractured OPCed mask data and have evaluated the efficiency of reducing the writing shot counts using the repeating patterns with this software. In this evaluation, we have used many actual device production data obtained from the member companies of Mask D2I. To the extraction software, we added new functions for extracting common repeating patterns from a set of multiple masks, and studied how this step affects the ratio of reducing the shot counts in comparison to the case of utilization of the repeating patterns for single mask. We have also developed a software that uses the result of extracting repeating patterns and prepares writing-data for the MCC/CP writing system which has been developed at the Mask Writing Equipment Technology Research Laboratory. With this software, we have examined how EB proximity effect on CP writing affects in reducing the shot count where CP shots with large CD errors have to be divided into VSB shots. In this paper we will report on making common CP mask from a set of multiple actual device data by using these software, and will also report on the results of CP writing and calculation of writing-TAT by MCC/CP writing system.

  17. Visual Masking During Pursuit Eye Movements

    ERIC Educational Resources Information Center

    White, Charles W.

    1976-01-01

    Visual masking occurs when one stimulus interferes with the perception of another stimulus. Investigates which matters more for visual masking--that the target and masking stimuli are flashed on the same part of the retina, or, that the target and mask appear in the same place. (Author/RK)

  18. Conceptual Masking: How One Picture Captures Attention from Another Picture.

    ERIC Educational Resources Information Center

    Loftus, Geoffrey R.; And Others

    1988-01-01

    Five experiments studied operations of conceptual masking--the reduction of conceptual memory performance for an initial stimulus when it is followed by a masking picture process. The subjects were 337 undergraduates at the University of Washington (Seattle). Conceptual masking is distinguished from perceptual masking. (TJH)

  19. Are Masking-Based Models of Risk Useful?

    PubMed

    Gisiner, Robert C

    2016-01-01

    As our understanding of directly observable effects from anthropogenic sound exposure has improved, concern about "unobservable" effects such as stress and masking have received greater attention. Equal energy models of masking such as power spectrum models have the appeal of simplicity, but do they offer biologically realistic assessments of the risk of masking? Data relevant to masking such as critical ratios, critical bandwidths, temporal resolution, and directional resolution along with what is known about general mammalian antimasking mechanisms all argue for a much more complicated view of masking when making decisions about the risk of masking inherent in a given anthropogenic sound exposure scenario.

  20. An alternative method of fabricating sub-micron resolution masks using excimer laser ablation

    NASA Astrophysics Data System (ADS)

    Hayden, C. J.; Eijkel, J. C. T.; Dalton, C.

    2004-06-01

    In the work presented here, an excimer laser micromachining system has been used successfully to fabricate high-resolution projection and contact masks. The contact masks were subsequently used to produce chrome-gold circular ac electro-osmotic pump (cACEOP) microelectrode arrays on glass substrates, using a conventional contact photolithography process. The contact masks were produced rapidly (~15 min each) and were found to be accurate to sub-micron resolution, demonstrating an alternative route for mask fabrication. Laser machined masks were also used in a laser-projection system, demonstrating that such fabrication techniques are also suited to projection lithography. The work addresses a need for quick reproduction of high-resolution contact masks, given their rapid degradation when compared to non-contact masks.

  1. Mask process correction (MPC) modeling and its application to EUV mask for electron beam mask writer EBM-7000

    NASA Astrophysics Data System (ADS)

    Kamikubo, Takashi; Ohnishi, Takayuki; Hara, Shigehiro; Anze, Hirohito; Hattori, Yoshiaki; Tamamushi, Shuichi; Bai, Shufeng; Wang, Jen-Shiang; Howell, Rafael; Chen, George; Li, Jiangwei; Tao, Jun; Wiley, Jim; Kurosawa, Terunobu; Saito, Yasuko; Takigawa, Tadahiro

    2010-09-01

    In electron beam writing on EUV mask, it has been reported that CD linearity does not show simple signatures as observed with conventional COG (Cr on Glass) masks because they are caused by scattered electrons form EUV mask itself which comprises stacked heavy metals and thick multi-layers. To resolve this issue, Mask Process Correction (MPC) will be ideally applicable. Every pattern is reshaped in MPC. Therefore, the number of shots would not increase and writing time will be kept within reasonable range. In this paper, MPC is extended to modeling for correction of CD linearity errors on EUV mask. And its effectiveness is verified with simulations and experiments through actual writing test.

  2. Does technology acceleration equate to mask cost acceleration?

    NASA Astrophysics Data System (ADS)

    Trybula, Walter J.; Grenon, Brian J.

    2003-06-01

    The technology acceleration of the ITRS Roadmap has many implications on both the semiconductor sup-plier community and the manufacturers. INTERNATIONAL SEMATECH has revaluated the projected cost of advanced technology masks. Building on the methodology developed in 1996 for mask costs, this work provided a critical review of mask yields and factors relating to the manufacture of photolithography masks. The impact of the yields provided insight into the learning curve for leading edge mask manufac-turing. The projected mask set cost was surprising, and the ability to provide first and second year cost estimates provided additional information on technology introduction. From this information, the impact of technology acceleration can be added to the projected yields to evaluate the impact on mask costs.

  3. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture extreme ultraviolet scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking. OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs that are more tolerant to mask errors.

  4. Fast synthesis of topographic mask effects based on rigorous solutions

    NASA Astrophysics Data System (ADS)

    Yan, Qiliang; Deng, Zhijie; Shiely, James

    2007-10-01

    Topographic mask effects can no longer be ignored at technology nodes of 45 nm, 32 nm and beyond. As feature sizes become comparable to the mask topographic dimensions and the exposure wavelength, the popular thin mask model breaks down, because the mask transmission no longer follows the layout. A reliable mask transmission function has to be derived from Maxwell equations. Unfortunately, rigorous solutions of Maxwell equations are only manageable for limited field sizes, but impractical for full-chip optical proximity corrections (OPC) due to the prohibitive runtime. Approximation algorithms are in demand to achieve a balance between acceptable computation time and tolerable errors. In this paper, a fast algorithm is proposed and demonstrated to model topographic mask effects for OPC applications. The ProGen Topographic Mask (POTOMAC) model synthesizes the mask transmission functions out of small-sized Maxwell solutions from a finite-difference-in-time-domain (FDTD) engine, an industry leading rigorous simulator of topographic mask effect from SOLID-E. The integral framework presents a seamless solution to the end user. Preliminary results indicate the overhead introduced by POTOMAC is contained within the same order of magnitude in comparison to the thin mask approach.

  5. Oronasal mask may compromise the efficacy of continuous positive airway pressure on OSA treatment: is there evidence for avoiding the oronasal route?

    PubMed

    Andrade, Rafaela Garcia Santos; Madeiro, Fernanda; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2016-11-01

    Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.

  6. Brightness masking is modulated by disparity structure.

    PubMed

    Pelekanos, Vassilis; Ban, Hiroshi; Welchman, Andrew E

    2015-05-01

    The luminance contrast at the borders of a surface strongly influences surface's apparent brightness, as demonstrated by a number of classic visual illusions. Such phenomena are compatible with a propagation mechanism believed to spread contrast information from borders to the interior. This process is disrupted by masking, where the perceived brightness of a target is reduced by the brief presentation of a mask (Paradiso & Nakayama, 1991), but the exact visual stage that this happens remains unclear. In the present study, we examined whether brightness masking occurs at a monocular-, or a binocular-level of the visual hierarchy. We used backward masking, whereby a briefly presented target stimulus is disrupted by a mask coming soon afterwards, to show that brightness masking is affected by binocular stages of the visual processing. We manipulated the 3-D configurations (slant direction) of the target and mask and measured the differential disruption that masking causes on brightness estimation. We found that the masking effect was weaker when stimuli had a different slant. We suggest that brightness masking is partly mediated by mid-level neuronal mechanisms, at a stage where binocular disparity edge structure has been extracted. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Effectiveness of surgical masks against influenza bioaerosols.

    PubMed

    Makison Booth, C; Clayton, M; Crook, B; Gawn, J M

    2013-05-01

    Most surgical masks are not certified for use as respiratory protective devices (RPDs). In the event of an influenza pandemic, logistical and practical implications such as storage and fit testing will restrict the use of RPDs to certain high-risk procedures that are likely to generate large amounts of infectious bioaerosols. Studies have shown that in such circumstances increased numbers of surgical masks are worn, but the protection afforded to the wearer by a surgical mask against infectious aerosols is not well understood. To develop and apply a method for assessing the protection afforded by surgical masks against a bioaerosol challenge. A dummy test head attached to a breathing simulator was used to test the performance of surgical masks against a viral challenge. Several designs of surgical masks commonly used in the UK healthcare sector were evaluated by measuring levels of inert particles and live aerosolised influenza virus in the air, from in front of and behind each mask. Live influenza virus was measurable from the air behind all surgical masks tested. The data indicate that a surgical mask will reduce exposure to aerosolised infectious influenza virus; reductions ranged from 1.1- to 55-fold (average 6-fold), depending on the design of the mask. We describe a workable method to evaluate the protective efficacy of surgical masks and RPDs against a relevant aerosolised biological challenge. The results demonstrated limitations of surgical masks in this context, although they are to some extent protective. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  8. Economic consequences of high throughput maskless lithography

    NASA Astrophysics Data System (ADS)

    Hartley, John G.; Govindaraju, Lakshmi

    2005-11-01

    Many people in the semiconductor industry bemoan the high costs of masks and view mask cost as one of the significant barriers to bringing new chip designs to market. All that is needed is a viable maskless technology and the problem will go away. Numerous sites around the world are working on maskless lithography but inevitably, the question asked is "Wouldn't a one wafer per hour maskless tool make a really good mask writer?" Of course, the answer is yes, the hesitation you hear in the answer isn't based on technology concerns, it's financial. The industry needs maskless lithography because mask costs are too high. Mask costs are too high because mask pattern generators (PG's) are slow and expensive. If mask PG's become much faster, mask costs go down, the maskless market goes away and the PG supplier is faced with an even smaller tool demand from the mask shops. Technical success becomes financial suicide - or does it? In this paper we will present the results of a model that examines some of the consequences of introducing high throughput maskless pattern generation. Specific features in the model include tool throughput for masks and wafers, market segmentation by node for masks and wafers and mask cost as an entry barrier to new chip designs. How does the availability of low cost masks and maskless tools affect the industries tool makeup and what is the ultimate potential market for high throughput maskless pattern generators?

  9. Scatterometry on pelliclized masks: an option for wafer fabs

    NASA Astrophysics Data System (ADS)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  10. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    PubMed

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full-head mask.

  11. Ternary cyclodextrin polyurethanes containing phosphate groups: Synthesis and complexation of ciprofloxacin.

    PubMed

    Moreira, Mirna Pereira; Andrade, George Ricardo Santana; de Araujo, Marcia Valeria Gaspar; Kubota, Tatiana; Gimenez, Iara F

    2016-10-20

    Synthesis of ternary polyurethanes (PUs) from hexamethylenediisocyanate, β-cyclodextrin and β-glycerophosphate (acid and calcium salt) was studies varying synthesis parameters such as monomer proportion, heating method (reflux and microwave), and catalyst amount. Favorable conditions were provided by microwave irradiation and use of β-glycerophosphoric acid although the results suggest that it is possible to obtain ternary PUs with the calcium salt. FTIR data indicated the existence of secondary urea linkages. After characterization of ternary PUs by FTIR spectroscopy, XRD and thermal analysis, as well as evidences that the cyclodextrin cavities remained active toward inclusion of guest molecules, the possibility of inclusion of the antibiotic ciprofloxacin was evaluated. Absence of ciprofloxacin melting peak in DSC curves indicated that it is molecularly dispersed within the polymer, possibly included in the cyclodextrin. In vitro release experiments suggested additional non-inclusion interactions, showing also that the use of dialysis membranes may mask the actual release profile. Copyright © 2016. Published by Elsevier Ltd.

  12. Rethinking smallpox.

    PubMed

    Weiss, Martin M; Weiss, Peter D; Mathisen, Glenn; Guze, Phyllis

    2004-12-01

    The potential consequences of a competently executed smallpox attack have not been adequately considered by policy makers. The possibility of release of an aerosolized and/or bioengineered virus must be anticipated and planned for. The transmission and infectivity of variola virus are examined. Arguments for and against pre-event vaccination are offered. The likely morbidity and mortality that would ensue from implementation of a mass pre-event vaccination program, within reasonable boundaries, are known. The extent of contagion that could result from an aerosolized release of virus is unknown and may have been underestimated. Pre-event vaccination of first responders is urged, and voluntary vaccination programs should be offered to the public. Two defenses against a vaccine-resistant, engineered variola virus are proposed for consideration. Methisazone, an overlooked drug, is reported to be effective for prophylaxis only. The extent of reduction in the incidence of smallpox with use of this agent is uncertain. It is useless for treatment of clinical smallpox. N-100 respirators (face masks) worn by uninfected members of the public may prevent transmission of the virus.

  13. Comparison of Cloud and Aerosol Detection between CERES Edition 3 Cloud Mask and CALIPSO Version 2 Data Products

    NASA Astrophysics Data System (ADS)

    Trepte, Qing; Minnis, Patrick; Sun-Mack, Sunny; Trepte, Charles

    Clouds and aerosol play important roles in the global climate system. Accurately detecting their presence, altitude, and properties using satellite radiance measurements is a crucial first step in determining their influence on surface and top-of-atmosphere radiative fluxes. This paper presents a comparison analysis of a new version of the Clouds and Earth's Radiant Energy System (CERES) Edition 3 cloud detection algorithms using Aqua MODIS data with the recently released Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) Version 2 Vertical Feature Mask (VFM). Improvements in CERES Edition 3 cloud mask include dust detection, thin cirrus tests, enhanced low cloud detection at night, and a smoother transition from mid-latitude to polar regions. For the CALIPSO Version 2 data set, changes to the lidar calibration can result in significant improvements to its identification of optically thick aerosol layers. The Aqua and CALIPSO satellites, part of the A-train satellite constellation, provide a unique opportunity for validating passive sensor cloud and aerosol detection using an active sensor. In this paper, individual comparison cases will be discussed for different types of clouds and aerosols over various surfaces, for daytime and nighttime conditions, and for regions ranging from the tropics to the poles. Examples will include an assessment of the CERES detection algorithm for optically thin cirrus, marine stratus, and polar night clouds as well as its ability to characterize Saharan dust plumes off the African coast. With the CALIPSO lidar's unique ability to probe the vertical structure of clouds and aerosol layers, it provides an excellent validation data set for cloud detection algorithms, especially for polar nighttime clouds.

  14. Facial and ocular deposition of nebulized budesonide: effects of face mask design.

    PubMed

    Harris, Keith W; Smaldone, Gerald C

    2008-02-01

    In vivo case reports and in vitro studies have indicated that aerosol therapy using face masks can result in drug deposition on the face and in the eyes, and that face mask design may affect drug delivery. To test different mask/nebulizer combinations for budesonide, a nebulized steroid used to treat pediatric patients with asthma. Using high-performance liquid chromatography, drug delivery (inhaled mass), facial, and ocular deposition of budesonide aerosols were studied in vitro using a ventilated face facsimile (tidal volume, 50 mL; rate, 25 breaths/min, duty cycle 0.4), a tight-fitting test mask, a standard commercial mask, and a prototype mask designed to optimize delivery by reducing particle inertia. Nebulizer insertion into the mask (front loaded vs bottom loaded) was also tested. Particle size was measured by cascade impaction. Pari LC Plus (PARI Respiratory Equipment; Midlothian, VA) and MistyNeb (Allegiance; McGaw Park, IL) nebulizers were tested. Inhaled mass for tight-fitting and prototype masks was similar (13.2 +/- 1.85% vs 14.4 +/- 0.67% [percentage of nebulizer charge], p = 0.58) and significantly greater than for the commercial mask (3.03 +/- 0.26%, p = 0.005). Mask insertion of nebulizer was a key factor (inhaled mass: front loaded vs bottom loaded, 8.23 +/- 0.18% vs 3.03 +/- 0.26%; p = 0.005). Ocular deposition varied by an order of magnitude and was a strong function of mask design (4.77 +/- 0.24% vs 0.35 +/- 0.05%, p = 0.002, tight fitting vs prototype). Particle sizes (7.3 to 9 microm) were larger than previously reported for budesonide. For pediatric breathing patterns, mask design is a key factor defining budesonide delivery to the lungs, face, and eyes. Front-loaded nebulizer mask combinations are more efficient than bottom-loaded systems.

  15. A New MRI Masking Technique Based on Multi-Atlas Brain Segmentation in Controls and Schizophrenia: A Rapid and Viable Alternative to Manual Masking.

    PubMed

    Del Re, Elisabetta C; Gao, Yi; Eckbo, Ryan; Petryshen, Tracey L; Blokland, Gabriëlla A M; Seidman, Larry J; Konishi, Jun; Goldstein, Jill M; McCarley, Robert W; Shenton, Martha E; Bouix, Sylvain

    2016-01-01

    Brain masking of MRI images separates brain from surrounding tissue and its accuracy is important for further imaging analyses. We implemented a new brain masking technique based on multi-atlas brain segmentation (MABS) and compared MABS to masks generated using FreeSurfer (FS; version 5.3), Brain Extraction Tool (BET), and Brainwash, using manually defined masks (MM) as the gold standard. We further determined the effect of different masking techniques on cortical and subcortical volumes generated by FreeSurfer. Images were acquired on a 3-Tesla MR Echospeed system General Electric scanner on five control and five schizophrenia subjects matched on age, sex, and IQ. Automated masks were generated from MABS, FS, BET, and Brainwash, and compared to MM using these metrics: a) volume difference from MM; b) Dice coefficients; and c) intraclass correlation coefficients. Mean volume difference between MM and MABS masks was significantly less than the difference between MM and FS or BET masks. Dice coefficient between MM and MABS was significantly higher than Dice coefficients between MM and FS, BET, or Brainwash. For subcortical and left cortical regions, MABS volumes were closer to MM volumes than were BET or FS volumes. For right cortical regions, MABS volumes were closer to MM volumes than were BET volumes. Brain masks generated using FreeSurfer, BET, and Brainwash are rapidly obtained, but are less accurate than manually defined masks. Masks generated using MABS, in contrast, resemble more closely the gold standard of manual masking, thereby offering a rapid and viable alternative. Copyright © 2015 by the American Society of Neuroimaging.

  16. Nanoimprint wafer and mask tool progress and status for high volume semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Matsuoka, Yoichi; Seki, Junichi; Nakayama, Takahiro; Nakagawa, Kazuki; Azuma, Hisanobu; Yamamoto, Kiyohito; Sato, Chiaki; Sakai, Fumio; Takabayashi, Yukio; Aghili, Ali; Mizuno, Makoto; Choi, Jin; Jones, Chris E.

    2016-10-01

    Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash* Imprint Lithography (J-FIL*) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are many criteria that determine whether a particular technology is ready for wafer manufacturing. Defectivity and mask life play a significant role relative to meeting the cost of ownership (CoO) requirements in the production of semiconductor devices. Hard particles on a wafer or mask create the possibility of inducing a permanent defect on the mask that can impact device yield and mask life. By using material methods to reduce particle shedding and by introducing an air curtain system, the lifetime of both the master mask and the replica mask can be extended. In this work, we report results that demonstrate a path towards achieving mask lifetimes of better than 1000 wafers. On the mask side, a new replication tool, the FPA-1100 NR2 is introduced. Mask replication is required for nanoimprint lithography (NIL), and criteria that are crucial to the success of a replication platform include both particle control, resolution and image placement accuracy. In this paper we discuss the progress made in both feature resolution and in meeting the image placement specification for replica masks.

  17. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    NASA Astrophysics Data System (ADS)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  18. Mask strategy at International SEMATECH

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2002-08-01

    International SEMATECH (ISMT) is a consortium consisting of 13 leading semiconductor manufacturers from around the globe. Its objective is to develop the infrastructure necessary for its member companies to realize the International Technology Roadmap for Semiconductors (ITRS) through efficiencies of shared development resources and knowledge. The largest area of effort is lithography, recognized as a crucial enabler for microelectronics technology progress. Within the Lithography Division, most of the efforts center on mask-related issues. The development strategy at International SEMATCH will be presented and the interlock of lithography projects clarified. Because of the limited size of the mask production equipment market, the business case is weak for aggressive investment commensurate with the pace of the International Technology Roadmap for Semiconductors. With masks becoming the overwhelming component of lithography cost, new ways of reducing or eliminating mask costs are being explored. Will mask technology survive without a strong business case? Will the mask industry limit the growth of the semiconductor industry? Are advanced masks worth their escalating cost? An analysis of mask cost from the perspective of mask value imparted to the user is presented with examples and generic formulas for the reader to apply independently. A key part to the success for both International SEMATECH and the industry globally will be partnerships on both the local level between mask-maker and mask-user, and the macro level where global collaborations will be necessary to resolve technology development cost challenges.

  19. 2013 mask industry survey

    NASA Astrophysics Data System (ADS)

    Malloy, Matt

    2013-09-01

    A comprehensive survey was sent to merchant and captive mask shops to gather information about the mask industry as an objective assessment of its overall condition. 2013 marks the 12th consecutive year for this process. Historical topics including general mask profile, mask processing, data and write time, yield and yield loss, delivery times, maintenance, and returns were included and new topics were added. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. While each year's survey includes minor updates based on feedback from past years and the need to collect additional data on key topics, the bulk of the survey and reporting structure have remained relatively constant. A series of improvements is being phased in beginning in 2013 to add value to a wider audience, while at the same time retaining the historical content required for trend analyses of the traditional metrics. Additions in 2013 include topics such as top challenges, future concerns, and additional details in key aspects of mask masking, such as the number of masks per mask set per ground rule, minimum mask resolution shipped, and yield by ground rule. These expansions beyond the historical topics are aimed at identifying common issues, gaps, and needs. They will also provide a better understanding of real-life mask requirements and capabilities for comparison to the International Technology Roadmap for Semiconductors (ITRS).

  20. Mask pattern generator employing EPL technology

    NASA Astrophysics Data System (ADS)

    Yoshioka, Nobuyuki; Yamabe, Masaki; Wakamiya, Wataru; Endo, Nobuhiro

    2003-08-01

    Mask cost is one of crucial issues in device fabrication, especially in SoC (System on a Chip) with small-volume production. The cost mainly depends on productivity of mask manufacturing tools such as mask writers and defect inspection tools. EPL (Electron Projection Lithography) has been developing as a high-throughput electron beam exposure technology that will succeed optical lithography. The application of EPL technology to mask writing will result in high productivity and contribute to decrease the mask cost. The concept of a mask pattern generator employing EPL technology is proposed in this paper. It is very similar to EPL technology used for pattern printing on a wafer. The mask patterns on the glass substrate are exposed by projecting the basic circuit patterns formed on the mother EPL mask. One example of the mother EPL mask is a stencil type made with 200-mm Si wafer. The basic circuit patterns are IP patterns and logical primitive patterns such as cell libraries (AND, OR, Inverter, Flip-Flop and etc.) to express the SoC device patterns. Since the SoC patterns are exposed with its collective units such as IP and logical primitive patterns by using this method, the high throughput will be expected comparing with conventional mask E-beam writers. In this paper, the mask pattern generator with the EPL technology is proposed. The concept, its advantages and issues to be solved are discussed.

  1. Shadows alter facial expressions of Noh masks.

    PubMed

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety)", which highly appreciates subtle emotional expressions in the darkness.

  2. The Meaning behind the Mask. [Lesson Plan].

    ERIC Educational Resources Information Center

    National Endowment for the Humanities (NFAH), Washington, DC.

    In this lesson plan, students explore the cultural significance of masks. After exploring the world of African masks and storytelling, they create masks that tell stories of their own. In these six lessons, students first recall contexts in which masks are worn in the United States, and then discuss their use in stories. Students then investigate…

  3. Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking

    ERIC Educational Resources Information Center

    Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.

    2011-01-01

    In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…

  4. Masks: The Artist in Me

    ERIC Educational Resources Information Center

    Skophammer, Karen

    2009-01-01

    Whether masks are made from cardboard, papier-mache, metal, wood, leather, fabric, clay or any combination of these materials, they bring out the artist in people. Young children like to wear masks when they play to pretend they were another person or animal. Masks let them fantasize and be creative. The author's students made masks representing…

  5. 46 CFR 197.322 - Surface-supplied helmets and masks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Surface-supplied helmets and masks. 197.322 Section 197... helmets and masks. (a) Each surface-supplied helmet or mask must have— (1) A nonreturn valve at the attachment point between helmet or mask and umbilical that closes readily and positively; (2) An exhaust...

  6. 37 CFR 211.3 - Mask work fees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  7. 37 CFR 211.3 - Mask work fees.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  8. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    PubMed

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  9. EUVL mask patterning with blanks from commercial suppliers

    NASA Astrophysics Data System (ADS)

    Yan, Pei-Yang; Zhang, Guojing; Nagpal, Rajesh; Shu, Emily Y.; Li, Chaoyang; Qu, Ping; Chen, Frederick T.

    2004-12-01

    Extreme Ultraviolet Lithography (EUVL) reflective mask blank development includes low thermal expansion material fabrication, mask substrate finishing, reflective multi-layer (ML) and capping layer deposition, buffer (optional)/absorber stack deposition, EUV specific metrology, and ML defect inspection. In the past, we have obtained blanks deposited with various layer stacks from several vendors. Some of them are not commercial suppliers. As a result, the blank and patterned mask qualities are difficult to maintain and improve. In this paper we will present the evaluation results of the EUVL mask pattering processes with the complete EUVL mask blanks supplied by the commercial blank supplier. The EUVL mask blanks used in this study consist of either quartz or ULE substrates which is a type of low thermal expansion material (LTEM), 40 pairs of molybdenum/silicon (Mo/Si) ML layer, thin ruthenium (Ru) capping layer, tantalum boron nitride (TaBN) absorber, and chrome (Cr) backside coating. No buffer layer is used. Our study includes the EUVL mask blank characterization, patterned EUVL mask characterization, and the final patterned EUVL mask flatness evaluation.

  10. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    PubMed

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  11. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial.

    PubMed

    Neuzeret, Pierre-Charles; Morin, Laurent

    2017-11-01

    Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  12. Emergent Access to the Airway and Chest in American Football Players.

    PubMed

    Swartz, Erik E; Mihalik, Jason P; Decoster, Laura C; Al-Darraji, Sossan; Bric, Justin

    2015-07-01

    American football has the highest rate of fatalities and catastrophic injuries of any US sport. The equipment designed to protect athletes from these catastrophic events challenges the ability of medical personnel to obtain neutral spine alignment and immobilization during airway and chest access for emergency life-support delivery. To compare motion, time, and difficulty during removal of American football helmets, face masks, and shoulder pads. Quasi-experimental, crossover study. Controlled laboratory. We recruited 40 athletic trainers (21 men, 19 women; age = 33.7 ± 11.2 years, height = 173.1 ± 9.2 cm, mass = 80.7 ± 17.1 kg, experience = 10.6 ± 10.4 years). Paired participants conducted 16 trials in random order for each of 4 helmet, face-mask, and shoulder-pad combinations. An 8-camera, 3-dimensional motion-capture system was used to record head motion in live models wearing properly fitted helmets and shoulder pads. Time and perceived difficulty (modified Borg CR-10). Helmet removal resulted in greater motion than face-mask removal, respectively, in the sagittal (14.88°, 95% confidence interval [CI] = 13.72°, 16.04° versus 7.04°, 95% CI = 6.20°, 7.88°; F(1,19) = 187.27, P < .001), frontal (7.00°, 95% CI = 6.47°, 7.53° versus 4.73°, 95% CI = 4.20°, 5.27°; F1,19 = 65.34, P < .001), and transverse (7.00°, 95% CI = 6.49°, 7.50° versus 4.49°, 95% CI = 4.07°, 4.90°; F(1,19) = 68.36, P < .001) planes. Face-mask removal from Riddell 360 helmets took longer (31.22 seconds, 95% CI = 27.52, 34.91 seconds) than from Schutt ION 4D helmets (20.45 seconds, 95% CI = 18.77, 22.12 seconds) or complete ION 4D helmet removal (26.40 seconds, 95% CI = 23.46, 29.35 seconds). Athletic trainers required less time to remove the Riddell Power with RipKord (21.96 seconds, 95% CI = 20.61°, 23.31° seconds) than traditional shoulder pads (29.22 seconds, 95% CI = 27.27, 31.17 seconds; t(19) = 9.80, P < .001). Protective equipment worn by American football players must eventually be removed for imaging and medical treatment. Our results fill a gap in the evidence to support current recommendations for prehospital emergent management in patients wearing protective football equipment. Helmet face masks and shoulder pads with quick-release designs allow for clinically acceptable removal times without inducing additional motion or difficulty.

  13. Central masking with bilateral cochlear implants

    PubMed Central

    Lin, Payton; Lu, Thomas; Zeng, Fan-Gang

    2013-01-01

    Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system. PMID:23363113

  14. Rescue therapy by switching to total face mask after failure of face mask-delivered noninvasive ventilation in do-not-intubate patients in acute respiratory failure.

    PubMed

    Lemyze, Malcolm; Mallat, Jihad; Nigeon, Olivier; Barrailler, Stéphanie; Pepy, Florent; Gasan, Gaëlle; Vangrunderbeeck, Nicolas; Grosset, Philippe; Tronchon, Laurent; Thevenin, Didier

    2013-02-01

    To evaluate the impact of switching to total face mask in cases where face mask-delivered noninvasive mechanical ventilation has already failed in do-not-intubate patients in acute respiratory failure. Prospective observational study in an ICU and a respiratory stepdown unit over a 12-month study period. Switching to total face mask, which covers the entire face, when noninvasive mechanical ventilation using facial mask (oronasal mask) failed to reverse acute respiratory failure. Seventy-four patients with a do-not-intubate order and treated by noninvasive mechanical ventilation for acute respiratory failure. Failure of face mask-delivered noninvasive mechanical ventilation was associated with a three-fold increase in in-hospital mortality (36% vs. 10.5%; p = 0.009). Nevertheless, 23 out of 36 patients (64%) in whom face mask-delivered noninvasive mechanical ventilation failed to reverse acute respiratory failure and, therefore, switched to total face mask survived hospital discharge. Reasons for switching from facial mask to total face mask included refractory hypercapnic acute respiratory failure (n = 24, 66.7%), painful skin breakdown or facial mask intolerance (n = 11, 30%), and refractory hypoxemia (n = 1, 2.7%). In the 24 patients switched from facial mask to total face mask because of refractory hypercapnia, encephalopathy score (3 [3-4] vs. 2 [2-3]; p < 0.0001), PaCO2 (87 ± 25 mm Hg vs. 70 ± 17 mm Hg; p < 0.0001), and pH (7.24 ± 0.1 vs. 7.32 ± 0.09; p < 0.0001) significantly improved after 2 hrs of total face mask-delivered noninvasive ventilation. Patients switched early to total face mask (in the first 12 hrs) developed less pressure sores (n = 5, 24% vs. n = 13, 87%; p = 0.0002), despite greater length of noninvasive mechanical ventilation within the first 48 hrs (44 hrs vs. 34 hrs; p = 0.05) and less protective dressings (n = 2, 9.5% vs. n = 8, 53.3%; p = 0.007). The optimal cutoff value for face mask-delivered noninvasive mechanical ventilation duration in predicting facial pressure sores was 11 hrs (area under the receiver operating characteristic curve, 0.86 ± 0.04; 95% confidence interval 0.76-0.93; p < 0.0001; sensitivity, 84%; specificity, 71%). In patients in hypercapnic acute respiratory failure, for whom escalation to intubation is deemed inappropriate, switching to total face mask can be proposed as a last resort therapy when face mask-delivered noninvasive mechanical ventilation has already failed to reverse acute respiratory failure. This strategy is particularly adapted to provide prolonged periods of continuous noninvasive mechanical ventilation while preventing facial pressure sores.

  15. PMJ panel discussion overview on mask complexities, cost, and cycle time in 32-nm system LSI generation: conflict or concurrent?

    NASA Astrophysics Data System (ADS)

    Hosono, Kunihiro; Kato, Kokoro

    2008-10-01

    This is a report on a panel discussion organized in Photomask Japan 2008, where the challenges about "Mask Complexities, Cost, and Cycle Time in 32-nm System LSI Generation" were addressed to have a look over the possible solutions from the standpoints of chipmaker, commercial mask shop, DA tool vendor and equipments makers. The wrap-up is as follows: Mask complexities justify the mask cost, while the acceptable increase rate of 32nm-mask cost significantly differs between mask suppliers or users side. The efficiency progress by new tools or DFM has driven their cycle-time reductions. Mask complexities and cost will be crucial issues prior to cycle time, and there seems to be linear correlation between them. Controlling complexity and cycle time requires developing a mix of advanced technologies, and especially for cost reduction, shot prices in writers and processing rates in inspection tools have been improved remarkably by tool makers. In addition, activities of consortium in Japan (Mask D2I) are expected to enhance the total optimization of mask design, writing and inspection. The cycle-time reduction potentially drives the lowering of mask cost, and, on the other, the pattern complexities and tighter mask specifications get in the way to 32nm generation as well as the nano-economics and market challenges. There are still many difficult problems in mask manufacturing now, and we are sure to go ahead to overcome a 32nm hurdle with the advances of technologies and collaborations by not only technologies but also finance.

  16. Proton-Mediated Block of Ca2+ Channels during Multivesicular Release Regulates Short-Term Plasticity at an Auditory Hair Cell Synapse

    PubMed Central

    Cho, Soyoun

    2014-01-01

    Synaptic vesicles release both neurotransmitter and protons during exocytosis, which may result in a transient acidification of the synaptic cleft that can block Ca2+ channels located close to the sites of exocytosis. Evidence for this effect has been reported for retinal ribbon-type synapses, but not for hair cell ribbon synapses. Here, we report evidence for proton release from bullfrog auditory hair cells when they are held at more physiological, in vivo–like holding potentials (Vh = −60 mV) that facilitate multivesicular release. During paired recordings of hair cells and afferent fibers, L-type voltage-gated Ca2+ currents showed a transient block, which was highly correlated with the EPSC amplitude (or the amount of glutamate release). This effect was masked at Vh = −90 mV due to the presence of a T-type Ca2+ current and blocked by strong pH buffering with HEPES or TABS. Increasing vesicular pH with internal methylamine in hair cells also abolished the transient block. High concentrations of intracellular Ca2+ buffer (10 mm BAPTA) greatly reduced exocytosis and abolished the transient block of the Ca2+ current. We estimate that this transient block is due to the rapid multivesicular release of ∼600–1300 H+ ions per synaptic ribbon. Finally, during a train of depolarizing pulses, paired pulse plasticity was significantly changed by using 40 mm HEPES in addition to bicarbonate buffer. We propose that this transient block of Ca2+ current leads to more efficient exocytosis per Ca2+ ion influx and it may contribute to spike adaptation at the auditory nerve. PMID:25429130

  17. Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.

    PubMed

    Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana

    2016-01-01

    The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.

  18. UNMASKING MASKED HYPERTENSION: PREVALENCE, CLINICAL IMPLICATIONS, DIAGNOSIS, CORRELATES, AND FUTURE DIRECTIONS

    PubMed Central

    Peacock, James; Diaz, Keith M.; Viera, Anthony J.; Schwartz, Joseph E.; Shimbo, Daichi

    2014-01-01

    ‘Masked hypertension’ is defined as having non-elevated clinic blood pressure (BP) with elevated out-of-clinic average BP, typically determined by ambulatory BP monitoring. Approximately 15–30% of adults with non-elevated clinic BP have masked hypertension. Masked hypertension is associated with increased risks of cardiovascular morbidity and mortality compared to sustained normotension (non-elevated clinic and ambulatory BP), which is similar to or approaching the risk associated with sustained hypertension (elevated clinic and ambulatory BP). The confluence of increased cardiovascular risk and a failure to be diagnosed by the conventional approach of clinic BP measurement makes masked hypertension a significant public health concern. However, many important questions remain. First, the definition of masked hypertension varies across studies. Further, the best approach in the clinical setting to exclude masked hypertension also remains unknown. It is unclear whether home BP monitoring is an adequate substitute for ambulatory BP monitoring in identifying masked hypertension. Few studies have examined the mechanistic pathways that may explain masked hypertension. Finally, scarce data are available on the best approach to treating individuals with masked hypertension. Herein, we review the current literature on masked hypertension including definition, prevalence, clinical implications, special patient populations, correlates, issues related to diagnosis, treatment, and areas for future research. PMID:24573133

  19. Removable pellicle for lithographic mask protection and handling

    DOEpatents

    Klebanoff, Leonard E.; Rader, Daniel J.; Hector, Scott D.; Nguyen, Khanh B.; Stulen, Richard H.

    2002-01-01

    A removable pellicle for a lithographic mask that provides active and robust particle protection, and which utilizes a traditional pellicle and two deployments of thermophoretic protection to keep particles off the mask. The removable pellicle is removably attached via a retaining structure to the mask substrate by magnetic attraction with either contacting or non-contacting magnetic capture mechanisms. The pellicle retaining structural is composed of an anchor piece secured to the mask substrate and a frame member containing a pellicle. The anchor piece and the frame member are in removable contact or non-contact by the magnetic capture or latching mechanism. In one embodiment, the frame member is retained in a floating (non-contact) relation to the anchor piece by magnetic levitation. The frame member and the anchor piece are provided with thermophoretic fins which are interdigitated to prevent particles from reaching the patterned area of the mask. Also, the anchor piece and mask are maintained at a higher temperature than the frame member and pellicle which also prevents particles from reaching the patterned mask area by thermophoresis. The pellicle can be positioned over the mask to provide particle protection during mask handling, inspection, and pumpdown, but which can be removed manually or robotically for lithographic use of the mask.

  20. Clinical comparison of positional accuracy and stability between dedicated versus conventional masks for immobilization in cranial stereotactic radiotherapy using 6-degree-of-freedom image guidance system-integrated platform.

    PubMed

    Ohtakara, Kazuhiro; Hayashi, Shinya; Tanaka, Hidekazu; Hoshi, Hiroaki; Kitahara, Masashi; Matsuyama, Katsuya; Okada, Hitoshi

    2012-02-01

    To compare the positioning accuracy and stability of two distinct noninvasive immobilization devices, a dedicated (D-) and conventional (C-) mask, and to evaluate the applicability of a 6-degrees-of-freedom (6D) correction, especially to the C-mask, based on our initial experience with cranial stereotactic radiotherapy (SRT) using ExacTrac (ET)/Robotics integrated into the Novalis Tx platform. The D- and C-masks were the BrainLAB frameless mask system and a general thermoplastic mask used for conventional radiotherapy such as whole brain irradiation, respectively. A total of 148 fractions in 71 patients and 125 fractions in 20 patients were analyzed for the D- and C-masks, respectively. For the C-mask, 3D correction was applied to the initial 10 patients, and thereafter, 6D correction was adopted. The 6D residual errors (REs) in the initial setup, after correction (pre-treatment), and during post-treatment were measured and compared. The D-mask provided no significant benefit for initial setup. The post-treatment median 3D vector displacements (interquatile range) were 0.38 mm (0.22, 0.60) and 0.74 mm (0.49, 1.04) for the D- and C-masks, respectively (p<0.001). The post-treatment maximal translational REs were within 1 mm and 2 mm for the D- and C-masks, respectively, and notably within 1.5 mm for the C-mask with 6D correction. The pre-treatment 3D vector displacements were significantly correlated with those for post-treatment in both masks. The D-mask confers positional stability acceptable for SRT. For the C-mask, 6D correction is also recommended, and an additional setup margin of 0.5 mm to that for the D-mask would be sufficient. The tolerance levels for the pre-treatment REs should similarly be set as small as possible for both systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. EUVL masks: paving the path for commercialization

    NASA Astrophysics Data System (ADS)

    Mangat, Pawitter J. S.; Hector, Scott D.

    2001-09-01

    Optical projection lithography has been the principal vehicle of semiconductor manufacturing for more than 20 years and is marching aggressively to satisfy the needs of semiconductor manufacturers for 100nm devices. However, the complexity of optical lithography continues to increase as wavelength reduction continues to 157nm. Extreme Ultraviolet Lithography (EUVL), with wavelength from 13-14 nm, is evolving as a leading next generation lithography option for semiconductor industry to stay on the path laid by Moore's Law. Masks are a critical part of the success of any technology and are considered to be high risk both for optical lithography and NGL technologies for sub-100nm lithography. Two key areas of EUV mask fabrication are reflective multilayer deposition and absorber patterning. In the case of reflective multilayers, delivering defect free multilayers for mask blanks is the biggest challenge. Defect mitigation is being explored as a possible option to smooth the multilayer defects in addition to optimization of the deposition process to reduce defect density. The mask patterning process needs focus on the defect-free absorber stack patterning process, mask cleaning, inspection and repair. In addition, there is considerable effort to understand by simulations, the defect printability, thermal and mechanical distortions, and non-telecentric illumination, to mention a few. To protect the finished mask from defects added during use, a removable pellicle strategy combined with thermophoretic protection during exposure is being developed. Recent migration to square form factor using low thermal expansion material (LTEM) is advantageous as historical developments in optical masks can be applied to EUV mask patterning. This paper addresses recent developments in the EUV mask patterning and highlights critical manufacturing process controls needed to fabricate defect-free full field masks with CD and image placement specifications for sub-70nm node lithography. No technology can be implemented without establishing the commercial infrastructure. The rising cost seems to be a major issue affecting the technology development. With respect to mask fabrication for commercial availability, a virtual mask shop analysis is presented that indicates that the process cost for EUVL masks are comparable to the high end optical mask with a reasonable yield. However, the cost for setting up a new mask facility is considerably high.

  2. The third data release of the Kilo-Degree Survey and associated data products

    NASA Astrophysics Data System (ADS)

    de Jong, Jelte T. A.; Verdois Kleijn, Gijs A.; Erben, Thomas; Hildebrandt, Hendrik; Kuijken, Konrad; Sikkema, Gert; Brescia, Massimo; Bilicki, Maciej; Napolitano, Nicola R.; Amaro, Valeria; Begeman, Kor G.; Boxhoorn, Danny R.; Buddelmeijer, Hugo; Cavuoti, Stefano; Getman, Fedor; Grado, Aniello; Helmich, Ewout; Huang, Zhuoyi; Irisarri, Nancy; La Barbera, Francesco; Longo, Giuseppe; McFarland, John P.; Nakajima, Reiko; Paolillo, Maurizio; Puddu, Emanuella; Radovich, Mario; Rifatto, Agatino; Tortora, Crescenzo; Valentijn, Edwin A.; Vellucci, Civita; Vriend, Willem-Jan; Amon, Alexandra; Blake, Chris; Choi, Ami; Conti, Ian Fenech; Gwyn, Stephen D. J.; Herbonnet, Ricardo; Heymans, Catherine; Hoekstra, Henk; Klaes, Dominik; Merten, Julian; Miller, Lance; Schneider, Peter; Viola, Massimo

    2017-08-01

    Context. The Kilo-Degree Survey (KiDS) is an ongoing optical wide-field imaging survey with the OmegaCAM camera at the VLT Survey Telescope. It aims to image 1500 square degrees in four filters (ugri). The core science driver is mapping the large-scale matter distribution in the Universe, using weak lensing shear and photometric redshift measurements. Further science cases include galaxy evolution, Milky Way structure, detection of high-redshift clusters, and finding rare sources such as strong lenses and quasars. Aims: Here we present the third public data release and several associated data products, adding further area, homogenized photometric calibration, photometric redshifts and weak lensing shear measurements to the first two releases. Methods: A dedicated pipeline embedded in the Astro-WISE information system is used for the production of the main release. Modifications with respect to earlier releases are described in detail. Photometric redshifts have been derived using both Bayesian template fitting, and machine-learning techniques. For the weak lensing measurements, optimized procedures based on the THELI data reduction and lensfit shear measurement packages are used. Results: In this third data release an additional 292 new survey tiles (≈300 deg2) stacked ugri images are made available, accompanied by weight maps, masks, and source lists. The multi-band catalogue, including homogenized photometry and photometric redshifts, covers the combined DR1, DR2 and DR3 footprint of 440 survey tiles (44 deg2). Limiting magnitudes are typically 24.3, 25.1, 24.9, 23.8 (5σ in a 2'' aperture) in ugri, respectively, and the typical r-band PSF size is less than 0.7''. The photometric homogenization scheme ensures accurate colours and an absolute calibration stable to ≈2% for gri and ≈3% in u. Separately released for the combined area of all KiDS releases to date are a weak lensing shear catalogue and photometric redshifts based on two different machine-learning techniques.

  3. Set Size and Mask Duration Do Not Interact in Object-Substitution Masking

    ERIC Educational Resources Information Center

    Argyropoulos, Ioannis; Gellatly, Angus; Pilling, Michael; Carter, Wakefield

    2013-01-01

    Object-substitution masking (OSM) occurs when a mask, such as four dots that surround a brief target item, onsets simultaneously with the target and offsets a short time after the target, rather than simultaneously with it. OSM is a reduction in accuracy of reporting the target with the temporally trailing mask, compared with the simultaneously…

  4. 21 CFR 868.5560 - Gas mask head strap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  5. Development of EUV mask handling technology at MIRAI-Selete

    NASA Astrophysics Data System (ADS)

    Ota, Kazuya; Amemiya, Mitsuaki; Taguchi, Takao; Kamono, Takashi; Kubo, Hiroyoshi; Takikawa, Tadahiko; Usui, Yoichi; Suga, Osamu

    2007-03-01

    We, MIRAI-Selete, started a new EUV mask program in April, 2006. Development of EUV mask handling technology is one of the key areas of the program. We plan to develop mask handling technology and to evaluate EUV mask carriers using Lasertec M3350, a particle inspection tool with the defect sensitivity less than 50nm PSL, and Mask Protection Engineering Tool (named "MPE Tool"). M3350 is a newly developed tool based on a conventional M1350 for EUV blanks inspection. Since our M3350 has a blank flipping mechanism in it, we can inspect the front and the back surface of the blank automatically. We plan to use the M3350 for evaluating particle adders during mask shipping, storage and handling. MPE Tool is a special tool exclusively developed for demonstration of pellicleless mask handling. It can handle a mask within a protective enclosure, which Canon and Nikon have been jointly proposing1, and also, can be modified to handle other type of carrier as the need arises.

  6. Dead space variability of face masks for valved holding chambers.

    PubMed

    Amirav, Israel; Newhouse, Michael T

    2008-03-01

    Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV and thus different performance. To compare both physical dead space and functional dead space of different face masks under various applied pressures. The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV). There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility. Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs.

  7. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture (NA) extreme ultraviolet (EUV) scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated, and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking (MRC). OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs which are more tolerant to mask errors.

  8. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    PubMed

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  9. Masks in Imaging Flow Cytometry

    PubMed Central

    Dominical, Venina; Samsel, Leigh; McCoy, J. Philip

    2016-01-01

    Data analysis in imaging flow cytometry incorporates elements of flow cytometry together with other aspects of morphological analysis of images. A crucial early step in this analysis is the creation of a mask to distinguish the portion of the image upon which further examination of specified features can be performed. Default masks are provided by the manufacturer of the imaging flow cytometer but additional custom masks can be created by the individual user for specific applications. Flawed or inaccurate masks can have a substantial negative impact on the overall analysis of a sample, thus great care must be taken to ensure the accuracy of masks. Here we discuss various types of masks and cite examples of their use. Furthermore we provide our insight for how to approach selecting and assessing the optimal mask for a specific analysis. PMID:27461256

  10. DUV mask writer for BEOL 90-nm technology layers

    NASA Astrophysics Data System (ADS)

    Hong, Dongsung; Krishnan, Prakash; Coburn, Dianna; Jeewakhan, Nazneen; Xie, Shengqi; Broussard, Joshua; Ferguson, Bradley; Green, Kent G.; Buck, Peter; Jackson, Curt A.; Martinez, Larry

    2003-12-01

    Mask CD resolution and uniformity requirements for back end of line (BEOL) layers for the 90nm Technology Node push the capability of I-line mask writers; yet, do not require the capability offered by more expensive 50KeV ebeam mask writers. This suite of mask layers seems to be a perfect match for the capabilities of the DUV mask writing tools, which offer a lower cost option to the 50KeV platforms. This paper will evaluate both the mask and wafer results from all three platforms of mask writers (50KeV VSB,ETEC Alta 4300TM DUV laser and ETEC Alta 3500TM I-line laser) for a Cypress 90nm node Metal 1 layer, and demonstrate the benefits of the DUV platform with no change to OPC for this layer.

  11. [Patients' reaction to pharmacists wearing a mask during their consultations].

    PubMed

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  12. Comparison of the upper airway dynamics of oronasal and nasal masks with positive airway pressure treatment using cine magnetic resonance imaging.

    PubMed

    Ebben, Matthew R; Milrad, Sara; Dyke, Jonathan P; Phillips, C Douglas; Krieger, Ana C

    2016-03-01

    It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep-disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine magnetic resonance imaging (cMRI). Ten subjects (eight men, two women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10, and 15 cm of H2O, while in the supine position along the sagittal plane. The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p = 0.016. No differences were found in the retroglossal region between mask styles. Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region.

  13. Comparison of the Upper Airway Dynamics of Oronasal and Nasal Masks with Positive Airway Pressure Treatment using cine Magnetic Resonance Imaging

    PubMed Central

    Ebben, Matthew R.; Milrad, Sara; Dyke, Jonathan P.; Phillips, C. Douglas; Krieger, Ana C.

    2016-01-01

    Purpose It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine Magnetic Resonance Imaging (cMRI). Methods 10-Subjects (8-men, 2-women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10 and 15 cm of H2O, while in the supine position along the sagittal plane. Results The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p=0.016. No differences were found in the retroglossal region between mask styles. Conclusions Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region. PMID:25924934

  14. Shadows Alter Facial Expressions of Noh Masks

    PubMed Central

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748

  15. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    NASA Astrophysics Data System (ADS)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  16. Effect of Masked Regions on Weak-lensing Statistics

    NASA Astrophysics Data System (ADS)

    Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi

    2013-09-01

    Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation. We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple χ2 analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg2 survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting χ2/n dof = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard ΛCDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.

  17. Study of shape evaluation for mask and silicon using large field of view

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka

    2010-09-01

    We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of pattern. •Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the form of the same location of Design, Mask, and Silicon in such a viewpoint. And we report it about algorithm of the image composition in Large Field.

  18. The impact of reverberant self-masking and overlap-masking effects on speech intelligibility by cochlear implant listeners (L).

    PubMed

    Kokkinakis, Kostas; Loizou, Philipos C

    2011-09-01

    The purpose of this study is to determine the relative impact of reverberant self-masking and overlap-masking effects on speech intelligibility by cochlear implant listeners. Sentences were presented in two conditions wherein reverberant consonant segments were replaced with clean consonants, and in another condition wherein reverberant vowel segments were replaced with clean vowels. The underlying assumption is that self-masking effects would dominate in the first condition, whereas overlap-masking effects would dominate in the second condition. Results indicated that the degradation of speech intelligibility in reverberant conditions is caused primarily by self-masking effects that give rise to flattened formant transitions. © 2011 Acoustical Society of America

  19. An investigation into the efficiency of disposable face masks.

    PubMed Central

    Rogers, K B

    1980-01-01

    Disposable face masks used in hospitals have been assessed for the protection afforded the patient and the wearer by challenges of simulated natural conditions of stress. Operating theatre masks made of synthetic materials allow the wearer to breathe through the masks, and these have been shown to protect the patient well but the wearer slightly less. Cheaper paper masks are worn for ward duties, and of these only the Promask protected in area in front of the wearer: air does not pass through this mask, expired air is prevented from passing forward, and the wearer breathes unfiltered air. All the other paper masks tested allowed many bacteria-laden particles to pass through them. PMID:7440756

  20. Wafer hot spot identification through advanced photomask characterization techniques

    NASA Astrophysics Data System (ADS)

    Choi, Yohan; Green, Michael; McMurran, Jeff; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike

    2016-10-01

    As device manufacturers progress through advanced technology nodes, limitations in standard 1-dimensional (1D) mask Critical Dimension (CD) metrics are becoming apparent. Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that the classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on subresolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. These items are not quantifiable with the 1D metrology techniques of today. Likewise, the mask maker needs advanced characterization methods in order to optimize the mask process to meet the wafer lithographer's needs. These advanced characterization metrics are what is needed to harmonize mask and wafer processes for enhanced wafer hot spot analysis. In this paper, we study advanced mask pattern characterization techniques and their correlation with modeled wafer performance.

  1. Tinnitus retraining therapy: mixing point and total masking are equally effective.

    PubMed

    Tyler, Richard S; Noble, William; Coelho, Claudia Barros; Ji, Haihong

    2012-01-01

    Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. Forty-eight tinnitus patients were randomly assigned to one of three groups: counseling, counseling plus bilateral noise generators set to completely mask the tinnitus, or counseling plus bilateral noise generators with a focus on the mixing point (partial masking just below total masking). A picture-based counseling protocol was used to assist in providing similar counseling among all three groups. The Tinnitus Handicap Questionnaire was administered before and after about 12 months of treatment. After 12 months, in the counseling group, three of 18 patients benefited significantly, in the mixing-point group, six of 19 patients benefited, and in the total masking group, four of 11 patients benefited from the treatment. The average decrease in the questionnaire was 16.7% for the counseling group, 31.6% for the retraining group, and 36.4% for the total masking group. No significant average differences among groups were observed. One premise of retraining therapy is incorrect; a focus on mixing-point masking is not required for habituation.

  2. Metacontrast masking and attention do not interact.

    PubMed

    Agaoglu, Sevda; Breitmeyer, Bruno; Ogmen, Haluk

    2016-07-01

    Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.

  3. Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask

    PubMed Central

    Shekar, Ashim; Balakrishna, Ramdas; Sudarshan, H.; Veena, G. C.; Bhuvaneshwari, S.

    2017-01-01

    The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery. PMID:29349045

  4. Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask.

    PubMed

    Jannu, Anubhav; Shekar, Ashim; Balakrishna, Ramdas; Sudarshan, H; Veena, G C; Bhuvaneshwari, S

    2017-12-01

    The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

  5. Preserved subliminal processing and impaired conscious access in schizophrenia

    PubMed Central

    Del Cul, Antoine; Dehaene, Stanislas; Leboyer, Marion

    2006-01-01

    Background Studies of visual backward masking have frequently revealed an elevated masking threshold in schizophrenia. This finding has frequently been interpreted as indicating a low-level visual deficit. However, more recent models suggest that masking may also involve late and higher-level integrative processes, while leaving intact early “bottom-up” visual processing. Objectives We tested the hypothesis that the backward masking deficit in schizophrenia corresponds to a deficit in the late stages of conscious perception, whereas the subliminal processing of masked stimuli is fully preserved. Method 28 patients with schizophrenia and 28 normal controls performed two backward-masking experiments. We used Arabic digits as stimuli and varied quasi-continuously the interval with a subsequent mask, thus allowing us to progressively “unmask” the stimuli. We finely quantified their degree of visibility using both objective and subjective measures to evaluate the threshold duration for access to consciousness. We also studied the priming effect caused by the variably masked numbers on a comparison task performed on a subsequently presented and highly visible target number. Results The threshold delay between digit and mask necessary for the conscious perception of the masked stimulus was longer in patients compared to control subjects. This higher consciousness threshold in patients was confirmed by an objective and a subjective measure, and both measures were highly correlated for patients as well as for controls. However, subliminal priming of masked numbers was effective and identical in patients compared to controls. Conclusions Access to conscious report of masked stimuli is impaired in schizophrenia, while fast bottom-up processing of the same stimuli, as assessed by subliminal priming, is preserved. These findings suggest a high-level origin of the masking deficit in schizophrenia, although they leave open for further research its exact relation to previously identified bottom-up visual processing abnormalities. PMID:17146006

  6. Lithographic qualification of high-transmission mask blank for 10nm node and beyond

    NASA Astrophysics Data System (ADS)

    Xu, Yongan; Faure, Tom; Viswanathan, Ramya; Lobb, Granger; Wistrom, Richard; Burns, Sean; Hu, Lin; Graur, Ioana; Bleiman, Ben; Fischer, Dan; Mignot, Yann; Sakamoto, Yoshifumi; Toda, Yusuke; Bolton, John; Bailey, Todd; Felix, Nelson; Arnold, John; Colburn, Matthew

    2016-04-01

    In this paper, we discuss the lithographic qualification of high transmission (High T) mask for Via and contact hole applications in 10nm node and beyond. First, the simulated MEEF and depth of focus (DoF) data are compared between the 6% and High T attnPSM masks with the transmission of High T mask blank varying from 12% to 20%. The 12% High T blank shows significantly better MEEF and larger DoF than those of 6% attnPSM mask blank, which are consistent with our wafer data. However, the simulations show no obvious advantage in MEEF and DoF when the blank transmittance is larger than 12%. From our wafer data, it has been seen that the common process window from High T mask is 40nm bigger than that from the 6% attnPSM mask. In the elongated bar structure with smaller aspect ratio, 1.26, the 12% High T mask shows significantly less develop CD pull back in the major direction. Compared to the High T mask, the optimized new illumination condition for 6% attnPSM shows limited improvement in MEEF and the DoF through pitch. In addition, by using the High T mask blank, we have also investigated the SRAF printing, side lobe printing and the resist profile through cross sections, and no patterning risk has been found for manufacturing. As part of this work new 12% High T mask blank materials and processes were developed, and a brief overview of key mask technology development results have been shared. Overall, it is concluded that the High T mask, 12% transmission, provides the most robust and extendable lithographic solution for 10nm node and beyond.

  7. Manufacturability study of masks created by inverse lithography technology (ILT)

    NASA Astrophysics Data System (ADS)

    Martin, Patrick M.; Progler, C. J.; Xiao, G.; Gray, R.; Pang, L.; Liu, Y.

    2005-11-01

    As photolithography is pushed to fabricate deep-sub wavelength devices for 90nm, 65nm and smaller technology nodes using available exposure tools (i.e., 248nm, 193nm steppers), photomask capability is becoming extremely critical. For example, PSM masks require more complicated processing; aggressive OPC makes the writing time longer and sometimes unpredictable; and, high MEEF imposes much more stringent demands on mask quality. Therefore, in order for any new lithography technology to be adopted into production, mask manufacturability must be studied thoroughly and carefully. In this paper we will present the mask manufacturability study on mask patterns created using Inverse Lithography Technology (ILT). Unlike conventional OPC methodologies, ILT uses a unique outcome-based technology to mathematically determine the mask features that produce the desired on-wafer results. ILT solves the most critical litho challenges of the deep sub-wavelength era. Potential benefits include: higher yield; expanded litho process windows; superb pattern fidelity at 90, 65 & 45-nm nodes; and reduced time-to-silicon - all without changing the existing lithography infrastructure and design-to-silicon flow. In this study a number of cell structures were selected and used as test patterns. "Luminized patterns" were generated for binary mask and attenuated phase-shift mask. Both conventional OPC patterns and "luminized patterns" were put on a test reticle side by side, and they all have a number of variations in term of correction aggressivity level and mask complexity. Mask manufacturability, including data fracturing, writing time, mask inspection, and metrology were studied. The results demonstrate that, by optimizing the inspection recipe, masks created using ILT technology can be made and qualified using current processes with a reasonable turn-around time.

  8. Whether Visual Information Loss of Expression by Community Pharmacist Masks to Effect a Change in Feeling of Trust among Help-seeker?

    PubMed

    Kishimoto, Keiko; Hasaka, Akiko; Yamaura, Katsunori; Fukushima, Noriko

    2016-01-01

    Pharmacy is required to shift toward human service such as hearing the complaints of health. But the study about help-seeking behavior to pharmacist is not really investigated. We hypothesized that a decrease in expression visibility, due to pharmacists' typical masks, may negatively impact help-seeker' trust in pharmacist. The sample included 100 drugstore customers aged ≥18 years. Participants were stratified by gender and randomly assigned to two groups: evaluation of clear-masked and normal-masked pharmacists. After viewing a video with either male or female pharmacists wearing either clear or normal masks, participants completed a questionnaire. The primary outcome was trust in pharmacist measured by the Trust Scale and the secondary outcome was impression of the pharmacist measured by nineteen pairs of adjectives. There were no differences by gender on trust scores. Results revealed that both male and female pharmacists who wore clear masks were rated as more trustworthy than normal-masked pharmacists (p<0.001, d=0.903, and p=0.001, d=0.716, respectively). Sixteen of nineteen adjectives reported for pharmacists wearing normal masks indicated greater negative intention than those with clear masks (d=0.431-1.469). In most cases, among pharmacists wearing clear masks, results showed positive correlations between trust and each impression adjective (r=0.279-0.710). Our findings indicate that pharmacists wearing normal masks, which partially hide facial expressions, may decrease customer's trust in pharmacist. Further, normal masks were associated with negative impression. To avoid the inhibition of help-seek behavior, we recommend that pharmacists wear a clear mask and increase non-verbal communication.

  9. The total face mask is more comfortable than the oronasal mask in noninvasive ventilation but is not associated with improved outcome.

    PubMed

    Chacur, Fernando Hauaji; Vilella Felipe, Luis Marcelo; Fernandes, Cintia Gonçalves; Lazzarini, Luiz Claudio Oliveira

    2011-01-01

    Noninvasive positive-pressure ventilation (NPPV) is commonly used to improve ventilation and oxygenation and avoid endotracheal intubation and mechanical ventilation. Although clinically indicated, most patients fail to use NPPV due to mask intolerance. A total face mask was designed to increase compliance, but whether this translates into better outcome (improvement in clinical and blood gas parameters and less intubation) is unknown. We compared the evolution of the clinical parameters, blood gases, levels of ventilatory support and rate of endotracheal intubation using the total face mask or the traditional oronasal mask during NPPV. A total of 60 patients were randomized to use either mask during NPPV. The clinical and laboratory parameters, as well as the level of ventilatory support were recorded at different intervals in both groups for up to 6 h. In addition, the tolerance for each mask and the need for endotracheal intubation were compared. Patients tolerated the total face mask significantly better (p = 0.0010) and used NPPV for a longer time (p = 0.0017) when compared with the oronasal mask. Just 1 patient switched to the total face mask because of intolerance. Although better tolerated, the rate of endotracheal intubation was similar in both groups (p = 0.4376), as was the clinical and laboratory evolution. The total face mask was more comfortable, allowing the patients to tolerate NPPV longer; however, these accomplishments did not translate into a better outcome. Due to its comfort, the total face mask should be available, at least as an option, in units where NPPVs are routinely applied. Copyright © 2011 S. Karger AG, Basel.

  10. Delivery of helium–oxygen mixture during spontaneous breathing: evaluation of three high-concentration face masks.

    PubMed

    Roche-Campo, Ferran; Vignaux, Laurence; Galia, Fabrice; Lyazidi, Aissam; Vargas, Frédéric; Texereau, Joëlle; Apiou-Sbirlea, Gabriela; Jolliet, Philippe; Brochard, Laurent

    2011-11-01

    To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He–O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He–O2 flow rates (7, 10, 12, and 15 L min(−1)). A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. He–O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.

  11. Effectiveness of face masks used to protect Beijing residents against particulate air pollution.

    PubMed

    Cherrie, John W; Apsley, Andrew; Cowie, Hilary; Steinle, Susanne; Mueller, William; Lin, Chun; Horwell, Claire J; Sleeuwenhoek, Anne; Loh, Miranda

    2018-06-01

    Many residents in Beijing use disposable face masks in an attempt to protect their health from high particulate matter (PM) concentrations. Retail masks may be certified to local or international standards, but their real-life performance may not confer the exposure reduction potential that is marketed. This study aimed to evaluate the effectiveness of a range of face masks that are commercially available in China. Nine masks claiming protection against fine PM (PM 2.5 ) were purchased from consumer outlets in Beijing. The masks' filtration efficiency was tested by drawing airborne diesel exhaust through a section of the material and measuring the PM 2.5 and black carbon (BC) concentrations upstream and downstream of the filtering medium. Four masks were selected for testing on volunteers. Volunteers were exposed to diesel exhaust inside an experimental chamber while performing sedentary tasks and active tasks. BC concentrations were continuously monitored inside and outside the mask. The mean per cent penetration for each mask material ranged from 0.26% to 29%, depending on the flow rate and mask material. In the volunteer tests, the average total inward leakage (TIL) of BC ranged from 3% to 68% in the sedentary tests and from 7% to 66% in the active tests. Only one mask type tested showed an average TIL of less than 10%, under both test conditions. Many commercially available face masks may not provide adequate protection, primarily due to poor facial fit. Our results indicate that further attention should be given to mask design and providing evidence-based guidance to consumers. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Inexpensive Masks for Film Deposition

    NASA Technical Reports Server (NTRS)

    Conley, W. R.

    1986-01-01

    Sputtered sprayed lines less than 2 millimeters wide made by superimposing masks with partially overlapping openings. Slits first cut in masks by stamping or other economical process. Masks superimposed so slits define new openings narrower than original slits.

  13. Dual-sided coded-aperture imager

    DOEpatents

    Ziock, Klaus-Peter [Clinton, TN

    2009-09-22

    In a vehicle, a single detector plane simultaneously measures radiation coming through two coded-aperture masks, one on either side of the detector. To determine which side of the vehicle a source is, the two shadow masks are inverses of each other, i.e., one is a mask and the other is the anti-mask. All of the data that is collected is processed through two versions of an image reconstruction algorithm. One treats the data as if it were obtained through the mask, the other as though the data is obtained through the anti-mask.

  14. Theta Oscillations During Active Sleep Synchronize The Developing Rubro-Hippocampal Sensorimotor Network

    PubMed Central

    Rio-Bermudez, Carlos Del; Kim, Jangjin; Sokoloff, Greta; Blumberg, Mark S.

    2017-01-01

    Summary Neuronal oscillations comprise a fundamental mechanism by which distant neural structures establish and express functional connectivity. Long-range functional connectivity between the hippocampus and other forebrain structures is enabled by theta oscillations. Here we show for the first time that the infant rat red nucleus (RN)—a brainstem sensorimotor structure— exhibits theta (4-7 Hz) oscillations restricted primarily to periods of active (REM) sleep. At postnatal day (P) 8, theta is expressed as brief bursts immediately following myoclonic twitches; by P12, theta oscillations are expressed continuously across bouts of active sleep. Simultaneous recordings from the hippocampus and RN at P12 show that theta oscillations in both structures are coherent, co-modulated, and mutually interactive during active sleep. Critically, at P12, inactivation of the medial septum eliminates theta in both structures. The developmental emergence of theta-dependent functional coupling between the hippocampus and RN parallels that between the hippocampus and prefrontal cortex. Accordingly, disruptions in the early expression of theta could underlie the cognitive and sensorimotor deficits associated with neurodevelopmental disorders such as autism and schizophrenia. PMID:28479324

  15. A prospective evaluation of open face masks for head and neck radiation therapy.

    PubMed

    Wiant, David; Squire, Sarah; Liu, Han; Maurer, Jacqueline; Lane Hayes, T; Sintay, Benjamin

    Head and neck (HN) radiation therapy patients are typically immobilized with closed thermoplastic masks that cover the face and may cause discomfort. In this work, we examine the use of open masks for HN radiation therapy. Fifty HN patients were prospectively randomized into 2 groups (25 closed masks, 25 open masks). The open-mask group was monitored with surface imaging to evaluate intrafraction motion. Both groups underwent daily volumetric imaging. All daily images were rigidly registered to their respective planning images to evaluate spinal canal and mandible position as a check for interfraction posture change. Posture changes were determined by the amount the spinal canal and mandible contours from the planning images had to be expanded to cover the structures on each daily image set. The vector length (VL) of the intrafraction linear translations, spine, and mandible positions for each open-mask patient were checked for correlation with fraction number using the Pearson r value. All patients were given a weekly survey ranking anxiety and claustrophobia from 0 to 10 (0 = no issue, 10 = extreme issue). The mean VL for all open-mask patients was 0.9 ± 0.5 mm (1 standard deviation). Only 1 patient showed significant correlation between VL and fraction number. The mean contour expansions to cover the spine and mandible were 1.5 ± 0.9 mm and 1.8 ± 1.3 mm for the closed-mask group, and 1.6 ± 0.8 mm and 1.8 ± 1.1 mm for the open-mask group. Both groups showed similar behavior relative to fraction number. The mean anxiety and claustrophobia scores were 1.63 and 1.44 for the closed-mask group, and 0.81 and 0.63 for the open-mask group. The groups were not significantly different. Open masks provide comparable immobilization and posture preservation to closed masks for HN radiation therapy. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  16. A novel anti-influenza copper oxide containing respiratory face mask.

    PubMed

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10)TCID(50)), while 4.67+/-1.35 log(10)TCID(50) were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10)TCID(50) and from the control masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.

  17. Modeling OPC complexity for design for manufacturability

    NASA Astrophysics Data System (ADS)

    Gupta, Puneet; Kahng, Andrew B.; Muddu, Swamy; Nakagawa, Sam; Park, Chul-Hong

    2005-11-01

    Increasing design complexity in sub-90nm designs results in increased mask complexity and cost. Resolution enhancement techniques (RET) such as assist feature addition, phase shifting (attenuated PSM) and aggressive optical proximity correction (OPC) help in preserving feature fidelity in silicon but increase mask complexity and cost. Data volume increase with rise in mask complexity is becoming prohibitive for manufacturing. Mask cost is determined by mask write time and mask inspection time, which are directly related to the complexity of features printed on the mask. Aggressive RET increase complexity by adding assist features and by modifying existing features. Passing design intent to OPC has been identified as a solution for reducing mask complexity and cost in several recent works. The goal of design-aware OPC is to relax OPC tolerances of layout features to minimize mask cost, without sacrificing parametric yield. To convey optimal OPC tolerances for manufacturing, design optimization should drive OPC tolerance optimization using models of mask cost for devices and wires. Design optimization should be aware of impact of OPC correction levels on mask cost and performance of the design. This work introduces mask cost characterization (MCC) that quantifies OPC complexity, measured in terms of fracture count of the mask, for different OPC tolerances. MCC with different OPC tolerances is a critical step in linking design and manufacturing. In this paper, we present a MCC methodology that provides models of fracture count of standard cells and wire patterns for use in design optimization. MCC cannot be performed by designers as they do not have access to foundry OPC recipes and RET tools. To build a fracture count model, we perform OPC and fracturing on a limited set of standard cells and wire configurations with all tolerance combinations. Separately, we identify the characteristics of the layout that impact fracture count. Based on the fracture count (FC) data from OPC and mask data preparation runs, we build models of FC as function of OPC tolerances and layout parameters.

  18. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness.

    PubMed

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-12-30

    Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. 6 major hospitals in 2 districts of Beijing, China. Cluster randomised controlled trial. 245 index cases with ILI. Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. ACTRN12613000852752; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness

    PubMed Central

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-01-01

    Rationale Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Objective Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. Setting 6 major hospitals in 2 districts of Beijing, China. Design Cluster randomised controlled trial. Participants 245 index cases with ILI. Intervention Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Main outcome measure Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. Results In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. Conclusions The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. Trial registration number ACTRN12613000852752; Results. PMID:28039289

  20. Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects

    PubMed Central

    Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana

    2015-01-01

    Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495

  1. A survey of practice patterns in the use of laryngeal mask by pediatric anesthesiologists.

    PubMed

    Patel, Anuradha; Clark, Scott R; Schiffmiller, Moshe; Schoenberg, Catherine; Tewfik, George

    2015-11-01

    Laryngeal mask is frequently the airway device of choice in routine general anesthesia for many procedures in children. Several studies have described the use of laryngeal masks in unconventional situations. This survey was undertaken to assess how laryngeal masks are being used by pediatric anesthesiologists. The 40-question electronic survey using SurveyMonkey™ was sent to 2740 members of the Society for Pediatric Anesthesia (SPA). This survey assessed the age, work environment, types of practice, and training levels, as well as clinical situations in which the practitioners use laryngeal masks across different pediatric age groups. Seven hundred and forty-three (27.1%) responses were obtained. The use of laryngeal mask increased as the patient age increased in nearly every queried situation. The practitioners routinely utilize laryngeal masks in a variety of challenging scenarios, such as in patients with a recent upper respiratory infection, in the difficult airway, remote locations, and long-duration surgeries. A small percentage of pediatric anesthesiologists use laryngeal masks in laparoscopic surgery and prone position procedures. Pediatric anesthesiologists are using laryngeal masks in both routine and challenging/unconventional situations. Although many of the uses for laryngeal masks are not explicitly stated in the manufacturer guidelines, literature and current practice support the use of laryngeal masks in several of these scenarios. © 2015 John Wiley & Sons Ltd.

  2. Interactions between concentric form-from-structure and face perception revealed by visual masking but not adaptation

    PubMed Central

    Feczko, Eric; Shulman, Gordon L.; Petersen, Steven E.; Pruett, John R.

    2014-01-01

    Findings from diverse subfields of vision research suggest a potential link between high-level aspects of face perception and concentric form-from-structure perception. To explore this relationship, typical adults performed two adaptation experiments and two masking experiments to test whether concentric, but not nonconcentric, Glass patterns (a type of form-from-structure stimulus) utilize a processing mechanism shared by face perception. For the adaptation experiments, subjects were presented with an adaptor for 5 or 20 s, prior to discriminating a target. In the masking experiments, subjects saw a mask, then a target, and then a second mask. Measures of discriminability and bias were derived and repeated measures analysis of variance tested for pattern-specific masking and adaptation effects. Results from Experiment 1 show no Glass pattern-specific effect of adaptation to faces; results from Experiment 2 show concentric Glass pattern masking, but not adaptation, may impair upright/inverted face discrimination; results from Experiment 3 show concentric and radial Glass pattern masking impaired subsequent upright/inverted face discrimination more than translational Glass pattern masking; and results from Experiment 4 show concentric and radial Glass pattern masking impaired subsequent face gender discrimination more than translational Glass pattern masking. Taken together, these findings demonstrate interactions between concentric form-from-structure and face processing, suggesting a possible common processing pathway. PMID:24563526

  3. Masking reduces orientation selectivity in rat visual cortex

    PubMed Central

    Alwis, Dasuni S.; Richards, Katrina L.

    2016-01-01

    In visual masking the perception of a target stimulus is impaired by a preceding (forward) or succeeding (backward) mask stimulus. The illusion is of interest because it allows uncoupling of the physical stimulus, its neuronal representation, and its perception. To understand the neuronal correlates of masking, we examined how masks affected the neuronal responses to oriented target stimuli in the primary visual cortex (V1) of anesthetized rats (n = 37). Target stimuli were circular gratings with 12 orientations; mask stimuli were plaids created as a binarized sum of all possible target orientations. Spatially, masks were presented either overlapping or surrounding the target. Temporally, targets and masks were presented for 33 ms, but the stimulus onset asynchrony (SOA) of their relative appearance was varied. For the first time, we examine how spatially overlapping and center-surround masking affect orientation discriminability (rather than visibility) in V1. Regardless of the spatial or temporal arrangement of stimuli, the greatest reductions in firing rate and orientation selectivity occurred for the shortest SOAs. Interestingly, analyses conducted separately for transient and sustained target response components showed that changes in orientation selectivity do not always coincide with changes in firing rate. Given the near-instantaneous reductions observed in orientation selectivity even when target and mask do not spatially overlap, we suggest that monotonic visual masking is explained by a combination of neural integration and lateral inhibition. PMID:27535373

  4. A further test of the linearity of temporal summation in forward masking.

    PubMed

    Plack, Christopher J; Carcagno, Samuele; Oxenham, Andrew J

    2007-10-01

    An experiment tested the hypothesis that the masking effects of two nonoverlapping forward maskers are summed linearly over time. First, the levels of individual noise maskers required to mask a brief 4-kHz signal presented at 10-, 20-, 30-, or 40-dB sensation level (SL) were found. The hypothesis predicts that a combination of the first masker presented at the level required to mask the 10-dB SL signal and the second masker presented at the level required to mask the 20-dB SL signal, should produce the same amount of masking as the converse situation (i.e., the first masker presented at the level required to mask the 20-dB SL signal and the second masker presented at the level required to mask the 10-dB SL signal), and similarly for the 30- and 40-dB SL signals. The results were consistent with the predictions.

  5. History and future of mask making

    NASA Astrophysics Data System (ADS)

    Levy, Ken L.

    1996-12-01

    The history of the mask industry has three main periods, which I call the Classical Period, the Dark Ages, and the Renaissance, by analogy with those periods in the history of Western Europe. During the Classical Period, people developed 1X masks and the technology to make them. In the Dark Ages, people exploited the equipment developed during the Classical Period to make 5X reduction reticle, ending the nobility of mask making. In today's Renaissance of mask making, a proliferation of mask types is requiring a rebirth of innovation and creativity. The Renaissance resembles the Classical Period: masks are once again strategic, and technological capability is once again the driver. Meanwhile, the mask industry is carrying forward the productivity and efficiency gains it achieved during the Dark Ages. We must create a new business and economic model to support these changes in the characteristics of the marketplace.

  6. Mechanically and electrically robust metal-mask design for organic CMOS circuits

    NASA Astrophysics Data System (ADS)

    Shintani, Michihiro; Qin, Zhaoxing; Kuribara, Kazunori; Ogasahara, Yasuhiro; Hiromoto, Masayuki; Sato, Takashi

    2018-04-01

    The design of metal masks for fabricating organic CMOS circuits requires the consideration of not only the electrical property of the circuits, but also the mechanical strength of the masks. In this paper, we propose a new design flow for metal masks that realizes coanalysis of the mechanical and electrical properties and enables design exploration considering the trade-off between the two properties. As a case study, we apply a “stitching technique” to the mask design of a ring oscillator and explore the best design. With this technique, mask patterns are divided into separate parts using multiple mask layers to improve the mechanical strength at the cost of high resistance of the vias. By a numerical experiment, the design trade-off of the stitching technique is quantitatively analyzed, and it is demonstrated that the proposed flow is useful for the exploration of the designs of metal masks.

  7. Design criteria for small coded aperture masks in gamma-ray astronomy

    NASA Technical Reports Server (NTRS)

    Sembay, S.; Gehrels, Neil

    1990-01-01

    Most theoretical work on coded aperture masks in X-ray and low-energy gamma-ray astronomy has concentrated on masks with large numbers of elements. For gamma-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyze by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. A particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns is developed. The results of such a computer analysis for masks up to dimension 5 x 5 unit cell are presented and it is concluded that there is a great deal of flexibility in the choice of mask pattern for each dimension.

  8. The technical consideration of multi-beam mask writer for production

    NASA Astrophysics Data System (ADS)

    Lee, Sang Hee; Ahn, Byung-Sup; Choi, Jin; Shin, In Kyun; Tamamushi, Shuichi; Jeon, Chan-Uk

    2016-10-01

    Multi-beam mask writer is under development to solve the throughput and patterning resolution problems in VSB mask writer. Theoretically, the writing time is appropriate for future design node and the resolution is improved with multi-beam mask writer. Many previous studies show the feasible results of resolution, CD control and registration. Although such technical results of development tool seem to be enough for mass production, there are still many unexpected problems for real mass production. In this report, the technical challenges of multi-beam mask writer are discussed in terms of production and application. The problems and issues are defined based on the performance of current development tool compared with the requirements of mask quality. Using the simulation and experiment, we analyze the specific characteristics of electron beam in multi-beam mask writer scheme. Consequently, we suggest necessary specifications for mass production with multi-beam mask writer in the future.

  9. Aerial image metrology for OPC modeling and mask qualification

    NASA Astrophysics Data System (ADS)

    Chen, Ao; Foong, Yee Mei; Thaler, Thomas; Buttgereit, Ute; Chung, Angeline; Burbine, Andrew; Sturtevant, John; Clifford, Chris; Adam, Kostas; De Bisschop, Peter

    2017-06-01

    As nodes become smaller and smaller, the OPC applied to enable these nodes becomes more and more sophisticated. This trend peaks today in curve-linear OPC approaches that are currently starting to appear on the roadmap. With this sophistication of OPC, the mask pattern complexity increases. CD-SEM based mask qualification strategies as they are used today are starting to struggle to provide a precise forecast of the printing behavior of a mask on wafer. An aerial image CD measurement performed on ZEISS Wafer-Level CD system (WLCD) is a complementary approach to mask CD-SEMs to judge the lithographical performance of the mask and its critical production features. The advantage of the aerial image is that it includes all optical effects of the mask such as OPC, SRAF, 3D mask effects, once the image is taken under scanner equivalent illumination conditions. Additionally, it reduces the feature complexity and analyzes the printing relevant CD.

  10. Time-Frequency Masking for Speech Separation and Its Potential for Hearing Aid Design

    PubMed Central

    Wang, DeLiang

    2008-01-01

    A new approach to the separation of speech from speech-in-noise mixtures is the use of time-frequency (T-F) masking. Originated in the field of computational auditory scene analysis, T-F masking performs separation in the time-frequency domain. This article introduces the T-F masking concept and reviews T-F masking algorithms that separate target speech from either monaural or binaural mixtures, as well as microphone-array recordings. The review emphasizes techniques that are promising for hearing aid design. This article also surveys recent studies that evaluate the perceptual effects of T-F masking techniques, particularly their effectiveness in improving human speech recognition in noise. An assessment is made of the potential benefits of T-F masking methods for the hearing impaired in light of the processing constraints of hearing aids. Finally, several issues pertinent to T-F masking are discussed. PMID:18974204

  11. The Effect of Conventional and Transparent Surgical Masks on Speech Understanding in Individuals with and without Hearing Loss.

    PubMed

    Atcherson, Samuel R; Mendel, Lisa Lucks; Baltimore, Wesley J; Patro, Chhayakanta; Lee, Sungmin; Pousson, Monique; Spann, M Joshua

    2017-01-01

    It is generally well known that speech perception is often improved with integrated audiovisual input whether in quiet or in noise. In many health-care environments, however, conventional surgical masks block visual access to the mouth and obscure other potential facial cues. In addition, these environments can be noisy. Although these masks may not alter the acoustic properties, the presence of noise in addition to the lack of visual input can have a deleterious effect on speech understanding. A transparent ("see-through") surgical mask may help to overcome this issue. To compare the effect of noise and various visual input conditions on speech understanding for listeners with normal hearing (NH) and hearing impairment using different surgical masks. Participants were assigned to one of three groups based on hearing sensitivity in this quasi-experimental, cross-sectional study. A total of 31 adults participated in this study: one talker, ten listeners with NH, ten listeners with moderate sensorineural hearing loss, and ten listeners with severe-to-profound hearing loss. Selected lists from the Connected Speech Test were digitally recorded with and without surgical masks and then presented to the listeners at 65 dB HL in five conditions against a background of four-talker babble (+10 dB SNR): without a mask (auditory only), without a mask (auditory and visual), with a transparent mask (auditory only), with a transparent mask (auditory and visual), and with a paper mask (auditory only). A significant difference was found in the spectral analyses of the speech stimuli with and without the masks; however, no more than ∼2 dB root mean square. Listeners with NH performed consistently well across all conditions. Both groups of listeners with hearing impairment benefitted from visual input from the transparent mask. The magnitude of improvement in speech perception in noise was greatest for the severe-to-profound group. Findings confirm improved speech perception performance in noise for listeners with hearing impairment when visual input is provided using a transparent surgical mask. Most importantly, the use of the transparent mask did not negatively affect speech perception performance in noise. American Academy of Audiology

  12. Prediction and outcomes of impossible mask ventilation: a review of 50,000 anesthetics.

    PubMed

    Kheterpal, Sachin; Martin, Lizabeth; Shanks, Amy M; Tremper, Kevin K

    2009-04-01

    There are no existing data regarding risk factors for impossible mask ventilation and limited data regarding its incidence. The authors sought to determine the incidence, predictors, and outcomes associated with impossible mask ventilation. The authors performed an observational study over a 4-yr period. For each adult patient undergoing a general anesthetic, preoperative patient characteristics, detailed airway physical exam, and airway outcome data were collected. The primary outcome was impossible mask ventilation defined as the inability to exchange air during bag-mask ventilation attempts, despite multiple providers, airway adjuvants, or neuromuscular blockade. Secondary outcomes included the final, definitive airway management technique and direct laryngoscopy view. The incidence of impossible mask ventilation was calculated. Independent (P < 0.05) predictors of impossible mask ventilation were identified by performing a logistic regression full model fit. Over a 4-yr period from 2004 to 2008, 53,041 attempts at mask ventilation were recorded. A total of 77 cases of impossible mask ventilation (0.15%) were observed. Neck radiation changes, male sex, sleep apnea, Mallampati III or IV, and presence of beard were identified as independent predictors. The receiver-operating-characteristic area under the curve for this model was 0.80 +/- 0.03. Nineteen impossible mask ventilation patients (25%) also demonstrated difficult intubation, with 15 being intubated successfully. Twelve patients required an alternative intubation technique, including two surgical airways and two patients who were awakened and underwent successful fiberoptic intubation. Impossible mask ventilation is an infrequent airway event that is associated with difficult intubation. Neck radiation changes represent the most significant clinical predictor of impossible mask ventilation in the patient dataset.

  13. Cost-effective masks for deep x-ray lithography

    NASA Astrophysics Data System (ADS)

    Scheunemann, Heinz-Ulrich; Loechel, Bernd; Jian, Linke; Schondelmaier, Daniel; Desta, Yohannes M.; Goettert, Jost

    2003-04-01

    The production of X-ray masks is one of the key techniques for X-ray lithography and the LIGA process. Different ways for the fabrication of X-ray masks has been established. Very sophisticated, difficult and expensive procedures are required to produce high precision and high quality X-ray masks. In order to minimize the cost of an X-ray mask, the mask blank must be inexpensive and readily available. The steps involved in the fabrication process must also be minimal. In the past, thin membranes made of titanium, silicon carbide, silicon nitride (2-5μm) or thick beryllium substrates (500μm) have been used as mask blanks. Thin titanium and silicon compounds have very high transparency for X-rays; therefore, these materials are predestined for use as mask membrane material. However, the handling and fabrication of thin membranes is very difficult, thus expensive. Beryllium is highly transparent to X-rays, but the processing and use of beryllium is risky due to potential toxicity. During the past few years graphite based X-ray masks have been in use at various research centers, but the sidewall quality of the generated resist patterns is in the range of 200-300 nm Ra. We used polished graphite to improve the sidewall roughness, but polished graphite causes other problems in the fabrication of X-ray masks. This paper describes the advantages associated with the use of polished graphite as mask blank as well as the fabrication process for this low cost X-ray mask. Alternative membrane materials will also be discussed.

  14. Non-invasive ventilation: evaluation of CO2 washout by intentional leaking in three recent oronasal masks. A pilot study.

    PubMed

    Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J

    2015-05-01

    Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.

  15. Effects of immobilization mask material on surface dose

    PubMed Central

    Hadley, Scott W.; Kelly, Robin; Lam, Kwok

    2005-01-01

    This work investigates the increase in surface dose caused by thermoplastic masks used for patient positioning and immobilization. A thermoplastic mask is custom fit by stretching a heated mask over the patient at the time of treatment simulation. This mask is then used at treatment to increase the reproducibility of the patient position. The skin sparing effect of mega‐voltage X‐ray beams can be reduced when the patient's skin surface is under the mask material. The sheet of thermoplastic mask has holes to reduce this effect and is available from one manufacturer with two different sizes of holes, one larger than the other. This work investigates the increase in surface dose caused by the mask material and quantifies the difference between the two samples of masks available. The change in the dose buildup was measured using an Attix parallel plate chamber by measuring tissue maximum ratios (TMRs) using solid water. Measurements were made with and without the mask material on the surface of the solid water for 6‐MV and 15‐MV X‐ray beams. The effective thickness of equivalent water was estimated from the TMR curves, and the increase in surface dose was estimated. The buildup effect was measured to be equivalent to 2.2 mm to 0.6 mm for masks that have been stretched by different amounts. The surface dose was estimated to change from 16% and 12% for 6 MV and 15 MV, respectively, to 27% to 61% for 6 MV and 18% to 40% for 15 MV with the mask samples. PACS number: 87.53.Dq PMID:15770192

  16. Method for validating cloud mask obtained from satellite measurements using ground-based sky camera.

    PubMed

    Letu, Husi; Nagao, Takashi M; Nakajima, Takashi Y; Matsumae, Yoshiaki

    2014-11-01

    Error propagation in Earth's atmospheric, oceanic, and land surface parameters of the satellite products caused by misclassification of the cloud mask is a critical issue for improving the accuracy of satellite products. Thus, characterizing the accuracy of the cloud mask is important for investigating the influence of the cloud mask on satellite products. In this study, we proposed a method for validating multiwavelength satellite data derived cloud masks using ground-based sky camera (GSC) data. First, a cloud cover algorithm for GSC data has been developed using sky index and bright index. Then, Moderate Resolution Imaging Spectroradiometer (MODIS) satellite data derived cloud masks by two cloud-screening algorithms (i.e., MOD35 and CLAUDIA) were validated using the GSC cloud mask. The results indicate that MOD35 is likely to classify ambiguous pixels as "cloudy," whereas CLAUDIA is likely to classify them as "clear." Furthermore, the influence of error propagations caused by misclassification of the MOD35 and CLAUDIA cloud masks on MODIS derived reflectance, brightness temperature, and normalized difference vegetation index (NDVI) in clear and cloudy pixels was investigated using sky camera data. It shows that the influence of the error propagation by the MOD35 cloud mask on the MODIS derived monthly mean reflectance, brightness temperature, and NDVI for clear pixels is significantly smaller than for the CLAUDIA cloud mask; the influence of the error propagation by the CLAUDIA cloud mask on MODIS derived monthly mean cloud products for cloudy pixels is significantly smaller than that by the MOD35 cloud mask.

  17. Fast mask writers: technology options and considerations

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.; Groves, Timothy; Hughes, Greg

    2011-04-01

    The semiconductor industry is under constant pressure to reduce production costs even as the complexity of technology increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which have added to the complexity of making masks because of the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low-k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that funding on the order of 50M to 90M for non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development poses a high risk for an individual supplier. The structure of the mask fabrication marketplace separates the mask writer equipment customer (the mask supplier) from the final customer (wafer manufacturer) that will be most effected by the increase in mask cost that will result if a high speed mask writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed.

  18. EFFECT OF MASKED REGIONS ON WEAK-LENSING STATISTICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi, E-mail: masato.shirasaki@utap.phys.s.u-tokyo.ac.jp

    2013-09-10

    Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation.more » We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple {chi}{sup 2} analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg{sup 2} survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting {chi}{sup 2}/n{sub dof} = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard {Lambda}CDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.« less

  19. Mask manufacturing improvement through capability definition and bottleneck line management

    NASA Astrophysics Data System (ADS)

    Strott, Al

    1994-02-01

    In 1989, Intel's internal mask operation limited itself to research and development activities and re-inspection and pellicle application of externally manufactured masks. Recognizing the rising capital cost of mask manufacturing at the leading edge, Intel's Mask Operation management decided to offset some of these costs by manufacturing more masks internally. This was the beginning of the challenge they set to manufacture at least 50% of Intel's mask volume internally, at world class performance levels. The first step in responding to this challenge was the completion of a comprehensive operation capability analysis. A series of bottleneck improvements by focus teams resulted in an average cycle time improvement to less than five days on all product and less than two days on critical products.

  20. Joint optimization of source, mask, and pupil in optical lithography

    NASA Astrophysics Data System (ADS)

    Li, Jia; Lam, Edmund Y.

    2014-03-01

    Mask topography effects need to be taken into consideration for more advanced resolution enhancement techniques in optical lithography. However, rigorous 3D mask model achieves high accuracy at a large computational cost. This work develops a combined source, mask and pupil optimization (SMPO) approach by taking advantage of the fact that pupil phase manipulation is capable of partially compensating for mask topography effects. We first design the pupil wavefront function by incorporating primary and secondary spherical aberration through the coefficients of the Zernike polynomials, and achieve optimal source-mask pair under the condition of aberrated pupil. Evaluations against conventional source mask optimization (SMO) without incorporating pupil aberrations show that SMPO provides improved performance in terms of pattern fidelity and process window sizes.

  1. Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    PubMed

    Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M

    2017-01-01

    Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children. Copyright © 2017 by Daedalus Enterprises.

  2. TMS effects on subjective and objective measures of vision: stimulation intensity and pre- versus post-stimulus masking.

    PubMed

    de Graaf, Tom A; Cornelsen, Sonja; Jacobs, Christianne; Sack, Alexander T

    2011-12-01

    Transcranial magnetic stimulation (TMS) can be used to mask visual stimuli, disrupting visual task performance or preventing visual awareness. While TMS masking studies generally fix stimulation intensity, we hypothesized that varying the intensity of TMS pulses in a masking paradigm might inform several ongoing debates concerning TMS disruption of vision as measured subjectively versus objectively, and pre-stimulus (forward) versus post-stimulus (backward) TMS masking. We here show that both pre-stimulus TMS pulses and post-stimulus TMS pulses could strongly mask visual stimuli. We found no dissociations between TMS effects on the subjective and objective measures of vision for any masking window or intensity, ruling out the option that TMS intensity levels determine whether dissociations between subjective and objective vision are obtained. For the post-stimulus time window particularly, we suggest that these data provide new constraints for (e.g. recurrent) models of vision and visual awareness. Finally, our data are in line with the idea that pre-stimulus masking operates differently from conventional post-stimulus masking. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Computing Challenges in Coded Mask Imaging

    NASA Technical Reports Server (NTRS)

    Skinner, Gerald

    2009-01-01

    This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

  4. Different effects of the two types of spatial pre-cueing: what precisely is "attention" in Di Lollo's and Enns' substitution masking theory?

    PubMed

    Luiga, I; Bachmann, T

    2007-11-01

    Enns and Di Lollo [Psychological Science, 8 (2), 135-139, 1997] have introduced the object substitution theory of visual masking. Object substitution masking occurs when focusing attention on the target is delayed. However, Posner (Quarterly Journal of Experimental Psychology, 32, 3-25, 1980) has already shown that attention can be directed to a target at least in two ways: intentionally (endogenously) and automatically (exogenously). We conducted two experiments to explore the effects of endogenous and exogenous cues on substitution masking. The results showed that when attention was shifted to the target location automatically (using a local peripheral pre-cue), masking was attenuated. A decrease in target identification dependent on a delay of mask offset, typical to substitution masking, was not observed. However, strong substitution masking occurred when the target location was not pre-cued or when attention was directed to the target location intentionally (using a symbolic pre-cue displayed centrally). The hypothesis of two different mechanisms of attentional control in substitution masking was confirmed.

  5. The attentional blink is not affected by backward masking of T2, T2-mask SOA, or level of T2 impoverishment.

    PubMed

    Jannati, Ali; Spalek, Thomas M; Lagroix, Hayley E P; Di Lollo, Vincent

    2012-02-01

    Identification of the second of two targets (T2) is impaired when presented shortly after the first (T1). This attentional blink (AB) is thought to arise from a delay in T2 processing during which T2 is vulnerable to masking. Conventional studies have measured T2 accuracy which is constrained by the 100% ceiling. We avoided this problem by using a dynamic threshold-tracking procedure that is inherently free from ceiling constraints. In two experiments we examined how AB magnitude is affected by three masking-related factors: (a) presence/absence of T2 mask, (b) T2-mask stimulus onset asynchrony (SOA), and (c) level of T2 impoverishment (signal-to-noise ratio [SNR]). In Experiment 1, overall accuracy decreased with T2-mask SOA. The magnitude of the AB, however, was invariant with SOA and with mask presence/absence. Experiment 2 further showed that the AB was invariant with T2 SNR. The relationship among mask presence/absence, SOA, and T2 SNR and the AB is encompassed in a qualitative model.

  6. The automatic back-check mechanism of mask tooling database and automatic transmission of mask tooling data

    NASA Astrophysics Data System (ADS)

    Xu, Zhe; Peng, M. G.; Tu, Lin Hsin; Lee, Cedric; Lin, J. K.; Jan, Jian Feng; Yin, Alb; Wang, Pei

    2006-10-01

    Nowadays, most foundries have paid more and more attention in order to reduce the CD width. Although the lithography technologies have developed drastically, mask data accuracy is still a big challenge than before. Besides, mask (reticle) price also goes up drastically such that data accuracy needs more special treatments.We've developed a system called eFDMS to guarantee the mask data accuracy. EFDMS is developed to do the automatic back-check of mask tooling database and the data transmission of mask tooling. We integrate our own EFDMS systems to engage with the standard mask tooling system K2 so that the upriver and the downriver processes of the mask tooling main body K2 can perform smoothly and correctly with anticipation. The competition in IC marketplace is changing from high-tech process to lower-price gradually. How to control the reduction of the products' cost more plays a significant role in foundries. Before the violent competition's drawing nearer, we should prepare the cost task ahead of time.

  7. Efficient analysis of three dimensional EUV mask induced imaging artifacts using the waveguide decomposition method

    NASA Astrophysics Data System (ADS)

    Shao, Feng; Evanschitzky, Peter; Fühner, Tim; Erdmann, Andreas

    2009-10-01

    This paper employs the Waveguide decomposition method as an efficient rigorous electromagnetic field (EMF) solver to investigate three dimensional mask-induced imaging artifacts in EUV lithography. The major mask diffraction induced imaging artifacts are first identified by applying the Zernike analysis of the mask nearfield spectrum of 2D lines/spaces. Three dimensional mask features like 22nm semidense/dense contacts/posts, isolated elbows and line-ends are then investigated in terms of lithographic results. After that, the 3D mask-induced imaging artifacts such as feature orientation dependent best focus shift, process window asymmetries, and other aberration-like phenomena are explored for the studied mask features. The simulation results can help lithographers to understand the reasons of EUV-specific imaging artifacts and to devise illumination and feature dependent strategies for their compensation in the optical proximity correction (OPC) for EUV masks. At last, an efficient approach using the Zernike analysis together with the Waveguide decomposition technique is proposed to characterize the impact of mask properties for the future OPC process.

  8. Flight and abduction in witchcraft and UFO lore.

    PubMed

    Musgrave, J B; Houran, J

    2000-04-01

    The lore surrounding the mythical Witches' Sabbat and contemporary reports of UFO abductions share three main characteristics: the use of masks, the appearance of "Men in Black," and references to flight and abduction. We review these three commonalities with particular focus on the aspect of flight and abduction. We argue that narratives of the Witches' Sabbat and UFO abductions share the same basic structure, common symbolism, and serve the same psychological needs of providing a coherent explanation for anomalous (ambiguous) experiences while simultaneously giving the experient a sense of freedom, release, and escape from the self. This pattern of similarities suggests the possibility that UFO abductions are a modern version of tales of flight to the Sabbat.

  9. Pressure Sensitive Tape in the Manufacture of Reusable Solid Rocket Motors

    NASA Technical Reports Server (NTRS)

    Champneys, Jeff

    2007-01-01

    ATK Launch Systems Inc. manufactures the reusable solid rocket motor (RSRM) for NASA's Space Shuttle program. They are used in pairs to launch the Space Shuttle. Pressure sensitive tape (PST) is used throughout the RSRM manufacturing process. A few PST functions are: 1) Secure labels; 2) Provide security seals; and 3) Protect tooling and flight hardware during various inert and live operations. Some of the PSTs used are: Cloth, Paper, Reinforced Teflon, Double face, Masking, and Vinyl. Factors given consideration for determining the type of tape to be used are: 1) Ability to hold fast; 2) Ability to release easily; 3) Ability to endure abuse; 4) Strength; and 5) Absence of adhesive residue after removal.

  10. In collaboration with mask suppliers for change management enhancement

    NASA Astrophysics Data System (ADS)

    Deng, Erwin; Lee, Chun Der; Lee, Rachel

    2013-06-01

    For those wafer fabs that have no their own maskshops, the main target of mask quality department is to gain stable mask quality performance through effective supplier management, and therefore achieves competitive business results. After dealing with lots of mask data preparation (MDP) quality problems with suppliers, we have found that incomplete change management procedures are one of major sources that induce incorrect mask data for writing. This article will share our experience in how to enhance change management flows with mask suppliers together and will also show the utility after a series of flow improvement actions.

  11. MTO-like reference mask modeling for advanced inverse lithography technology patterns

    NASA Astrophysics Data System (ADS)

    Park, Jongju; Moon, Jongin; Son, Suein; Chung, Donghoon; Kim, Byung-Gook; Jeon, Chan-Uk; LoPresti, Patrick; Xue, Shan; Wang, Sonny; Broadbent, Bill; Kim, Soonho; Hur, Jiuk; Choo, Min

    2017-07-01

    Advanced Inverse Lithography Technology (ILT) can result in mask post-OPC databases with very small address units, all-angle figures, and very high vertex counts. This creates mask inspection issues for existing mask inspection database rendering. These issues include: large data volumes, low transfer rate, long data preparation times, slow inspection throughput, and marginal rendering accuracy leading to high false detections. This paper demonstrates the application of a new rendering method including a new OASIS-like mask inspection format, new high-speed rendering algorithms, and related hardware to meet the inspection challenges posed by Advanced ILT masks.

  12. Optical inspection of NGL masks

    NASA Astrophysics Data System (ADS)

    Pettibone, Donald W.; Stokowski, Stanley E.

    2004-12-01

    For the last five years KLA-Tencor and our joint venture partners have pursued a research program studying the ability of optical inspection tools to meet the inspection needs of possible NGL lithographies. The NGL technologies that we have studied include SCALPEL, PREVAIL, EUV lithography, and Step and Flash Imprint Lithography. We will discuss the sensitivity of the inspection tools and mask design factors that affect tool sensitivity. Most of the work has been directed towards EUV mask inspection and how to optimize the mask to facilitate inspection. Our partners have succeeded in making high contrast EUV masks ranging in contrast from 70% to 98%. Die to die and die to database inspection of EUV masks have been achieved with a sensitivity that is comparable to what can be achieved with conventional photomasks, approximately 80nm defect sensitivity. We have inspected SCALPEL masks successfully. We have found a limitation of optical inspection when applied to PREVAIL stencil masks. We have run inspections on SFIL masks in die to die, reflected light, in an effort to provide feedback to improve the masks. We have used a UV inspection system to inspect both unpatterned EUV substrates (no coatings) and blanks (with EUV multilayer coatings). These inspection results have proven useful in driving down the substrate and blank defect levels.

  13. Forward masking of frequency modulationa

    PubMed Central

    Byrne, Andrew J.; Wojtczak, Magdalena; Viemeister, Neal F.

    2012-01-01

    Forward masking of sinusoidal frequency modulation (FM) was measured with three types of maskers: FM, amplitude modulation (AM), and a masker created by combining the magnitude spectrum of an FM tone with random component phases. For the signal FM rates used (5, 20, and 40 Hz), an FM masker raised detection thresholds in terms of frequency deviation by a factor of about 5 relative to without a masker. The AM masker produced a much smaller effect, suggesting that FM-to-AM conversion did not contribute substantially to the FM forward masking. The modulation depth of an FM masker had a nonmonotonic effect, with maximal masking observed at an intermediate value within the range of possible depths, while the random-phase FM masker produced less masking, arguing against a spectrally-based explanation for FM forward masking. Broad FM-rate selectivity for forward masking was observed for both 4-kHz and 500-Hz carriers. Thresholds measured as a function of the masker-signal delay showed slow recovery from FM forward masking, with residual masking for delays up to 500 ms. The FM forward-masking effect resembles that observed for AM [Wojtczak and Viemeister (2005). J. Acoust. Soc. Am. 188, 3198–3210] and may reflect modulation-rate selective neural adaptation to FM. PMID:23145618

  14. Automated imprint mask cleaning for step-and-flash imprint lithography

    NASA Astrophysics Data System (ADS)

    Singh, Sherjang; Chen, Ssuwei; Selinidis, Kosta; Fletcher, Brian; McMackin, Ian; Thompson, Ecron; Resnick, Douglas J.; Dress, Peter; Dietze, Uwe

    2009-03-01

    Step-and-Flash Imprint Lithography (S-FIL) is a promising lithography strategy for semiconductor manufacturing at device nodes below 32nm. The S-FIL 1:1 pattern transfer technology utilizes a field-by-field ink jet dispense of a low viscosity liquid resist to fill the relief pattern of the device layer etched into the glass mask. Compared to other sub 40nm CD lithography methods, the resulting high resolution, high throughput through clustering, 3D patterning capability, low process complexity, and low cost of ownership (CoO) of S-FIL makes it a widely accepted technology for patterned media as well as a promising mainstream option for future CMOS applications. Preservation of mask cleanliness is essential to avoid risk of repeated printing of defects. The development of mask cleaning processes capable of removing particles adhered to the mask surface without damaging the mask is critical to meet high volume manufacturing requirements. In this paper we have presented various methods of residual (cross-linked) resist removal and final imprint mask cleaning demonstrated on the HamaTech MaskTrack automated mask cleaning system. Conventional and non-conventional (acid free) methods of particle removal have been compared and the effect of mask cleaning on pattern damage and CD integrity is also studied.

  15. Masked polycythaemia vera: presenting features, response to treatment and clinical outcomes.

    PubMed

    Alvarez-Larrán, Alberto; Angona, Anna; Ancochea, Agueda; García-Pallarols, Francesc; Fernández, Concepción; Longarón, Raquel; Bellosillo, Beatriz; Besses, Carlos

    2016-01-01

    Masked polycythaemia vera (PV) has been proposed as a new entity with poorer outcome than overt PV. In this study, the initial clinical and laboratory characteristics, response to treatment and outcome of masked and overt PV were compared using red cell mass and haemoglobin or haematocrit levels for the distinction between both entities. Sixty-eight of 151 PV patients (45%) were classified as masked PV according to World Health Organisation diagnostic criteria, whereas 16 (11%) were classified as masked PV using the British Committee for Standards in Haematology (BCSH). In comparison with overt PV, a higher platelet count and a lower JAK2V617F allele burden at diagnosis were observed in masked PV. Patients with masked PV needed lower phlebotomies and responded faster to hydroxcarbamide than those with overt PV. Complete haematological response was more frequently achieved in masked than in overt PV (79% vs. 58%, P = 0.001). There were no significant differences in the duration of haematological response, the rate of resistance or intolerance to hydroxycarbamide and the probability of molecular response according to type of PV (masked vs. overt). Overall survival, rate of thrombosis and major bleeding, and probability of transformation was superimposable among patients with masked and overt PV. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Rigorous diffraction analysis using geometrical theory of diffraction for future mask technology

    NASA Astrophysics Data System (ADS)

    Chua, Gek S.; Tay, Cho J.; Quan, Chenggen; Lin, Qunying

    2004-05-01

    Advanced lithographic techniques such as phase shift masks (PSM) and optical proximity correction (OPC) result in a more complex mask design and technology. In contrast to the binary masks, which have only transparent and nontransparent regions, phase shift masks also take into consideration transparent features with a different optical thickness and a modified phase of the transmitted light. PSM are well-known to show prominent diffraction effects, which cannot be described by the assumption of an infinitely thin mask (Kirchhoff approach) that is used in many commercial photolithography simulators. A correct prediction of sidelobe printability, process windows and linearity of OPC masks require the application of rigorous diffraction theory. The problem of aerial image intensity imbalance through focus with alternating Phase Shift Masks (altPSMs) is performed and compared between a time-domain finite-difference (TDFD) algorithm (TEMPEST) and Geometrical theory of diffraction (GTD). Using GTD, with the solution to the canonical problems, we obtained a relationship between the edge on the mask and the disturbance in image space. The main interest is to develop useful formulations that can be readily applied to solve rigorous diffraction for future mask technology. Analysis of rigorous diffraction effects for altPSMs using GTD approach will be discussed.

  17. Reticles, write time, and the need for speed

    NASA Astrophysics Data System (ADS)

    Ackmann, Paul W.; Litt, Lloyd C.; Ning, Guo Xiang

    2014-10-01

    Historical data indicates reticle write times are increasing node-to-node. The cost of mask sets is increasing driven by the tighter requirements and more levels. The regular introduction of new generations of mask patterning tools with improved performance is unable to fully compensate for the increased data and complexity required. Write time is a primary metric that drives mask fabrication speed. Design (Raw data) is only the first step in the process and many interactions between mask and wafer technology such as OPC used, OPC efficiency for writers, fracture engines, and actual field size used drive total write time. Yield, technology, and inspection rules drive the remaining raw cycle time. Yield can be even more critical for speed of delivery as it drives re-writes and wasted time. While intrinsic process yield is important, repair capability is the reason mask delivery is still able to deliver 100% good reticles to the fab. Advanced nodes utilizing several layers of multiple patterning may require mask writer tool dedication to meet image placement specifications. This will increase the effective mask cycle time for a layer mask set and drive the need for additional mask write capability in order to deliver masks at the rate required by the wafer fab production schedules.

  18. An open-architecture approach to defect analysis software for mask inspection systems

    NASA Astrophysics Data System (ADS)

    Pereira, Mark; Pai, Ravi R.; Reddy, Murali Mohan; Krishna, Ravi M.

    2009-04-01

    Industry data suggests that Mask Inspection represents the second biggest component of Mask Cost and Mask Turn Around Time (TAT). Ever decreasing defect size targets lead to more sensitive mask inspection across the chip, thus generating too many defects. Hence, more operator time is being spent in analyzing and disposition of defects. Also, the fact that multiple Mask Inspection Systems and Defect Analysis strategies would typically be in use in a Mask Shop or a Wafer Foundry further complicates the situation. In this scenario, there is a need for a versatile, user friendly and extensible Defect Analysis software that reduces operator analysis time and enables correct classification and disposition of mask defects by providing intuitive visual and analysis aids. We propose a new vendor-neutral defect analysis software, NxDAT, based on an open architecture. The open architecture of NxDAT makes it easily extensible to support defect analysis for mask inspection systems from different vendors. The capability to load results from mask inspection systems from different vendors either directly or through a common interface enables the functionality of establishing correlation between inspections carried out by mask inspection systems from different vendors. This capability of NxDAT enhances the effectiveness of defect analysis as it directly addresses the real-life scenario where multiple types of mask inspection systems from different vendors co-exist in mask shops or wafer foundries. The open architecture also potentially enables loading wafer inspection results as well as loading data from other related tools such as Review Tools, Repair Tools, CD-SEM tools etc, and correlating them with the corresponding mask inspection results. A unique concept of Plug-In interface to NxDAT further enhances the openness of the architecture of NxDAT by enabling end-users to add their own proprietary defect analysis and image processing algorithms. The plug-in interface makes it possible for the end-users to make use of their collected knowledge through the years of experience in mask inspection process by encapsulating the knowledge into software utilities and plugging them into NxDAT. The plug-in interface is designed with the intent of enabling the pro-active mask defect analysis teams to build competitive differentiation into their defect analysis process while protecting their knowledge internally within their company. By providing interface with all major standard layout and mask data formats, NxDAT enables correlation of defect data on reticles with design and mask databases, further extending the effectiveness of defect analysis for D2DB inspection. NxDAT also includes many other advanced features for easy and fast navigation, visual display of defects, defect selection, multi-tier classification, defect clustering and gridding, sophisticated CD and contact measurement analysis, repeatability analysis such as adder analysis, defect trend, capture rate etc.

  19. Gain control in the sonar of odontocetes.

    PubMed

    Ya Supin, Alexander; Nachtigall, Paul E

    2013-06-01

    The sonar of odontocetes processes echo-signals within a wide range of echo levels. The level of echoes varies widely by tens of decibels depending on the level of the emitted sonar pulse, the target strength, the distance to the target, and the sound absorption by the water media. The auditory system of odontocetes must be capable of effective perception, analysis, and discrimination of echo-signals within all this variability. The sonar of odontocetes has several mechanisms to compensate for the echo-level variation (gain control). To date, several mechanisms of the biosonar gain control have been revealed in odontocetes: (1) adjustment of emitted sonar pulse levels (the longer the distance to the target, the higher the level of the emitted pulse), (2) short-term variation of hearing sensitivity based on forward masking of the echo by the preceding self-heard emitted pulse and subsequent release from the masking, and (3) active long-term control of hearing sensitivity. Recent investigations with the use of the auditory evoked-potential technique have demonstrated that these mechanisms effectively minimize the variation of the response to the echo when either the emitted sonar pulse level, or the target distance, or both vary within a wide range. A short review of these data is presented herein.

  20. SDSS-III Baryon Oscillation Spectroscopic Survey data release 12: Galaxy target selection and large-scale structure catalogues

    DOE PAGES

    Reid, Beth; Ho, Shirley; Padmanabhan, Nikhil; ...

    2015-11-17

    The Baryon Oscillation Spectroscopic Survey (BOSS), part of the Sloan Digital Sky Survey (SDSS) III project, has provided the largest survey of galaxy redshifts available to date, in terms of both the number of galaxy redshifts measured by a single survey, and the effective cosmological volume covered. Key to analysing the clustering of these data to provide cosmological measurements is understanding the detailed properties of this sample. Potential issues include variations in the target catalogue caused by changes either in the targeting algorithm or properties of the data used, the pattern of spectroscopic observations, the spatial distribution of targets formore » which redshifts were not obtained, and variations in the target sky density due to observational systematics. We document here the target selection algorithms used to create the galaxy samples that comprise BOSS. We also present the algorithms used to create large-scale structure catalogues for the final Data Release (DR12) samples and the associated random catalogues that quantify the survey mask. The algorithms are an evolution of those used by the BOSS team to construct catalogues from earlier data, and have been designed to accurately quantify the galaxy sample. Furthermore, the code used, designated mksample, is released with this paper.« less

  1. Preparation of core-shell CaCO3 capsules via Pickering emulsion templates.

    PubMed

    Wang, Xiaoli; Zhou, Weizheng; Cao, Jian; Liu, Weichang; Zhu, Shiping

    2012-04-15

    Micron size and food grade pristine CaCO(3) particles were used to stabilize an oil in water Pickering emulsion. The particles also acted as nucleation sites for the subsequent crystallization of CaCO(3) with the addition of CaCl(2) and CO(2) gas as precursors. After the controllable crystallization process, a dense CaCO(3) shell with a few microns in thickness was formed. The CaCO(3) shell was proven to be calcite without the presence of crystallization modifiers. The crystallization speed and the shell integrity were controlled by manipulating the addition of CaCl(2) amount during the different crystallization stages; therefore, the homogeneous nucleation in the bulk was almost inhibited, and the heterogeneous nucleation at the oil-water interface on pristine CaCO(3) particles was the main contribution to the growth of the shell. The encapsulated limonene flavor in CaCO(3) capsules showed a prolonged release in neutral water at 85°C, while a burst release at pH 2 water as expected. The method is a simple and scalable process for creating inorganic core-shell capsules and can be used for producing food grade capsules for controlling the flavor release or masking undesirable taste in mouth. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.

    PubMed

    Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano

    2015-08-01

    To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Analysis method to determine and characterize the mask mean-to-target and uniformity specification

    NASA Astrophysics Data System (ADS)

    Lee, Sung-Woo; Leunissen, Leonardus H. A.; Van de Kerkhove, Jeroen; Philipsen, Vicky; Jonckheere, Rik; Lee, Suk-Joo; Woo, Sang-Gyun; Cho, Han-Ku; Moon, Joo-Tae

    2006-06-01

    The specification of the mask mean-to-target (MTT) and uniformity is related to functions as: mask error enhancement factor, dose sensitivity and critical dimension (CD) tolerances. The mask MTT shows a trade-off relationship with the uniformity. Simulations for the mask MTT and uniformity (M-U) are performed for LOGIC devices of 45 and 37 nm nodes according to mask type, illumination condition and illuminator polarization state. CD tolerances and after develop inspection (ADI) target CD's in the simulation are taken from the 2004 ITRS roadmap. The simulation results allow for much smaller tolerances in the uniformity and larger offsets in the MTT than the values as given in the ITRS table. Using the parameters in the ITRS table, the mask uniformity contributes to nearly 95% of total CDU budget for the 45 nm node, and is even larger than the CDU specification of the ITRS for the 37 nm node. We also compared the simulation requirements with the current mask making capabilities. The current mask manufacturing status of the mask uniformity is barely acceptable for the 45 nm node, but requires process improvements towards future nodes. In particular, for the 37 nm node, polarized illumination is necessary to meet the ITRS requirements. The current mask linearity deviates for pitches smaller than 300 nm, which is not acceptable even for the 45 nm node. More efforts on the proximity correction method are required to improve the linearity behavior.

  4. GPS Antenna Data Needed : GPS Adjacent Band Compatibility Workshop Volpe Center, Cambridge MA

    DOT National Transportation Integrated Search

    2014-09-18

    Topics. 1. Technical Objective: Receiver Antenna Mask and Electronics Data. 2. Definition of Receiver Antenna Mask. 3. Use of Receiver Antenna Mask. 4. Approaches to Generate the Antenna Mask. 5. Request for Receiver Antenna Data. 6. Next Steps.

  5. [Recognition of visual objects under forward masking. Effects of cathegorial similarity of test and masking stimuli].

    PubMed

    Gerasimenko, N Iu; Slavutskaia, A V; Kalinin, S A; Kulikov, M A; Mikhaĭlova, E S

    2013-01-01

    In 38 healthy subjects accuracy and response time were examined during recognition of two categories of images--animals andnonliving objects--under forward masking. We revealed new data that masking effects depended of categorical similarity of target and masking stimuli. The recognition accuracy was the lowest and the response time was the most slow, when the target and masking stimuli belongs to the same category, that was combined with high dispersion of response times. The revealed effects were more clear in the task of animal recognition in comparison with the recognition of nonliving objects. We supposed that the revealed effects connected with interference between cortical representations of the target and masking stimuli and discussed our results in context of cortical interference and negative priming.

  6. Low-order aberration sensitivity of eighth-order coronagraph masks

    NASA Technical Reports Server (NTRS)

    Shaklan, Stuart B.; Green, Joseph J.

    2005-01-01

    In a recent paper, Kuchner, Crepp, and Ge describe new image-plane coronagraph mask designs that reject to eighth order the leakage of starlight caused by image motion at the mask, resulting in a substantial relaxation of image centroiding requirements compared to previous fourth-order and second-order masks. They also suggest that the new masks are effective at rejecting leakage caused by low-order aberrations (e.g., focus, coma, and astigmatism). In this paper, we derive the sensitivity of eighth-order masks to aberrations of any order and provide simulations of coronagraph behavior in the presence of optical aberrations.We find that the masks leak light as the fourth power of focus, astigmatism, coma, and trefoil. This has tremendous performance advantages for the Terrestrial Planet Finder Coronagraph.

  7. The influence of facial masking and sex on older adults' impressions of individuals with Parkinson's disease.

    PubMed

    Hemmesch, Amanda R; Tickle-Degnen, Linda; Zebrowitz, Leslie A

    2009-09-01

    Parkinson's disease (PD) involves facial masking, which may impair social interaction. Older adult observers who viewed segments of videotaped interviews of individuals with PD expressed less interest in relationships with women with higher masking and judged them as less supportive. Masking did not affect ratings of men in these domains, possibly because higher masking violates gender norms for expressivity in women but not in men. Observers formed less accurate ratings of the social supportiveness and social strain of women than men, and higher masking decreased accuracy for ratings of strain. Results suggest that some of the problems with social relationships in PD may be due to inaccurate impressions and reduced desire to interact with individuals with higher masking, especially women. (c) 2009 APA, all rights reserved.

  8. Improvement of neuronal differentiation by carbon monoxide: Role of pentose phosphate pathway.

    PubMed

    Almeida, Ana S; Soares, Nuno L; Sequeira, Catarina O; Pereira, Sofia A; Sonnewald, Ursula; Vieira, Helena L A

    2018-05-15

    Over the last decades, the silent-killer carbon monoxide (CO) has been shown to also be an endogenous cytoprotective molecule able to inhibit cell death and modulate mitochondrial metabolism. Neuronal metabolism is mostly oxidative and neurons also use glucose for maintaining their anti-oxidant status by generation of reduced glutathione (GSH) via the pentose-phosphate pathway (PPP). It is established that neuronal differentiation depends on reactive oxygen species (ROS) generation and signalling, however there is a lack of information about modulation of the PPP during adult neurogenesis. Thus, the main goal of this study was to unravel the role of CO on cell metabolism during neuronal differentiation, particularly by targeting PPP flux and GSH levels as anti-oxidant system. A human neuroblastoma SH-S5Y5 cell line was used, which differentiates into post-mitotic neurons by treatment with retinoic acid (RA), supplemented or not with CO-releasing molecule-A1 (CORM-A1). SH-SY5Y cell differentiation supplemented with CORM-A1 prompted an increase in neuronal yield production. It did, however, not alter glycolytic metabolism, but increased the PPP. In fact, CORM-A1 treatment stimulated (i) mRNA expression of 6-phosphogluconate dehydrogenase (PGDH) and transketolase (TKT), which are enzymes for oxidative and non-oxidative phases of the PPP, respectively and (ii) protein expression and activity of glucose 6-phosphate dehydrogenase (G6PD) the rate-limiting enzyme of the PPP. Likewise, whenever G6PD was knocked-down CO-induced improvement on neuronal differentiation was reverted, while pharmacological inhibition of GSH synthesis did not change CO's effect on the improvement of neuronal differentiation. Both results indicate the key role of PPP in CO-modulation of neuronal differentiation. Furthermore, at the end of SH-SY5Y neuronal differentiation process, CORM-A1 supplementation increased the ratio of reduced and oxidized glutathione (GSH/GSSG) without alteration of GSH metabolism. These data corroborate with PPP stimulation. In conclusion, CO improves neuronal differentiation of SH-S5Y5 cells by stimulating the PPP and modulating the GSH system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Forward Masking of the Speech-Evoked Auditory Brainstem Response.

    PubMed

    Hodge, Sarah E; Menezes, Denise C; Brown, Kevin D; Grose, John H

    2018-02-01

    The hypothesis tested was that forward masking of the speech-evoked auditory brainstem response (sABR) increases peak latency as an inverse function of masker-signal interval (Δt), and that the overall persistence of forward masking is age dependent. Older listeners exhibit deficits in forward masking. If forward-masked sABRs provide an objective measure of the susceptibility of speech sounds to prior stimulation, then this provides a novel approach to examining the age dependence of temporal processing. A /da/ stimulus forward masked by speech-shaped noise (Δt = 4-64 ms) was used to measure sABRs in 10 younger and nine older participants. Forward masking of subsegments of the /da/ stimulus (Δt = 16 ms) and click trains (Δt = 0-64 ms) was also measured. Forward-masked sABRs from young participants showed an increase in latency with decreasing Δt for the initial peak. Latency shifts for later peaks were smaller and more uniform. None of the peak latencies returned to baseline by Δt = 64 ms. Forward-masked /da/ subsegments showed peak latency shifts that did not depend simply on peak position, while forward-masked click trains showed latency shifts that were dependent on click position. The sABRs from older adults were less robust but confirmed the viability of the approach. Forward masking of the sABR provides an objective measure of the susceptibility of the auditory system to prior stimulation. Failure of recovery functions to return to baseline suggests an interaction between forward masking by the prior masker and temporal effects within the stimulus itself.

  10. Monte Carlo sensitivity analysis of EUV mask reflectivity and its impact on OPC accuracy

    NASA Astrophysics Data System (ADS)

    Chen, Yulu; Wood, Obert; Rankin, Jed; Gullikson, Eric; Meyer-Ilse, Julia; Sun, Lei; Qi, Zhengqing John; Goodwin, Francis; Kye, Jongwook

    2017-03-01

    Unlike optical masks which are transmissive optical elements, use of extreme ultraviolet (EUV) radiation requires a reflective mask structure - a multi-layer coating consisting of alternating layers of high-Z (wave impedance) and low-Z materials that provide enhanced reflectivity over a narrow wavelength band peaked at the Bragg wavelength.1 Absorber side wall angle, corner rounding,2 surface roughness,3 and defects4 affect mask performance, but even seemingly simple parameters like bulk reflectivity on mirror and absorber surfaces can have a profound influence on imaging. For instance, using inaccurate reflectivity values at small and large incident angles would diminish the benefits of source mask co-optimization (SMO) and result in larger than expected pattern shifts. The goal of our work is to calculate the variation in mask reflectivity due to various sources of inaccuracies using Monte Carlo simulations. Such calculation is necessary as small changes in the thickness and optical properties of the high-Z and low-Z materials can cause substantial variations in reflectivity. This is further complicated by undesirable intermixing between the two materials used to create the reflector.5 One of the key contributors to mask reflectivity fluctuation is identified to be the intermixing layer thickness. We also investigate the impacts on OPC when the wrong mask information is provided, and evaluate the deterioration of overlapping process window. For a hypothetical N7 via layer, the lack of accurate mask information costs 25% of the depth of focus at 5% exposure latitude. Our work would allow the determination of major contributors to mask reflectivity variation, drive experimental efforts of measuring such contributors, provide strategies to optimize mask reflectivity, and quantize the OPC errors due to imperfect mask modeling.

  11. Face Masks and Cough Etiquette Reduce the Cough Aerosol Concentration of Pseudomonas aeruginosa in People with Cystic Fibrosis.

    PubMed

    Wood, Michelle E; Stockwell, Rebecca E; Johnson, Graham R; Ramsay, Kay A; Sherrard, Laura J; Jabbour, Nassib; Ballard, Emma; O'Rourke, Peter; Kidd, Timothy J; Wainwright, Claire E; Knibbs, Luke D; Sly, Peter D; Morawska, Lidia; Bell, Scott C

    2018-02-01

    People with cystic fibrosis (CF) generate Pseudomonas aeruginosa in droplet nuclei during coughing. The use of surgical masks has been recommended in healthcare settings to minimize pathogen transmission between patients with CF. To determine if face masks and cough etiquette reduce viable P. aeruginosa aerosolized during coughing. Twenty-five adults with CF and chronic P. aeruginosa infection were recruited. Participants performed six talking and coughing maneuvers, with or without face masks (surgical and N95) and hand covering the mouth when coughing (cough etiquette) in an aerosol-sampling device. An Andersen Cascade Impactor was used to sample the aerosol at 2 meters from each participant. Quantitative sputum and aerosol bacterial cultures were performed, and participants rated the mask comfort levels during the cough maneuvers. During uncovered coughing (reference maneuver), 19 of 25 (76%) participants produced aerosols containing P. aeruginosa, with a positive correlation found between sputum P. aeruginosa concentration (measured as cfu/ml) and aerosol P. aeruginosa colony-forming units. There was a reduction in aerosol P. aeruginosa load during coughing with a surgical mask, coughing with an N95 mask, and cough etiquette compared with uncovered coughing (P < 0.001). A similar reduction in total colony-forming units was observed for both masks during coughing; yet, participants rated the surgical masks as more comfortable (P = 0.013). Cough etiquette provided approximately half the reduction of viable aerosols of the mask interventions during voluntary coughing. Talking was a low viable aerosol-producing activity. Face masks reduce cough-generated P. aeruginosa aerosols, with the surgical mask providing enhanced comfort. Cough etiquette was less effective at reducing viable aerosols.

  12. Masked Hypertension is Associated With Cognitive Decline in Geriatric Age-Geriatric MASked Hypertension and Cognition (G-MASH-cog) Study.

    PubMed

    Esme, Mert; Yavuz, Burcu Balam; Yavuz, Bunyamin; Asil, Serkan; Tuna Dogrul, Rana; Sumer, Fatih; Kilic, Mustafa Kemal; Kizilarslanoglu, Muhammet Cemal; Varan, Hacer Dogan; Sagir, Aykut; Balci, Cafer; Halil, Meltem; Cankurtaran, Mustafa

    2018-01-16

    Masked hypertension is described as high ambulatory blood pressure measurements (ABPM) where office blood pressure measurements are normal. Effect of hypertension on cognitive functions is well known. However, the effect of masked hypertension on cognitive functions is unclear. The aim of this study is to examine the relationship between masked hypertension and cognitive functions. One hundred-two normotensive patients admitted to the Geriatric Medicine outpatient clinic were included. Exclusion criteria were hypertension, dementia, major depression, and usage of antihypertensive medication. All patients underwent ABPM procedures and average daytime blood pressure, mean blood pressure at night and the 24-hour average blood pressure measurements were recorded. Comprehensive geriatric assessment tests and neuropsychological tests were administered. The diagnosis of masked hypertension was based on the definitions in the 2013 guideline of the European Society of Cardiology. Forty-four patients (43%) were diagnosed with masked hypertension. Patients with masked hypertension had significantly lower scores on Mini-Mental State Examination (MMSE) test, Quick Mild Cognitive Impairment Test (QMCI), and Categorical Fluency Test than the normotensive patients (p = .011; p = .046; and p = .004; respectively). Montreal Cognitive Assessment Scale test score was lower in masked hypertension, although this was not statistically significant. This study may indicate that geriatric patients with masked hypertension, compared to normotensive patients have decreased cognitive functions. Masked hypertension should be kept in mind while assessing older adults. When masked hypertension is detected, cognitive assessment is essential to diagnose possible cognitive dysfunction at early stage. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Culture, gender and health care stigma: Practitioners' response to facial masking experienced by people with Parkinson's disease.

    PubMed

    Tickle-Degnen, Linda; Zebrowitz, Leslie A; Ma, Hui-ing

    2011-07-01

    Facial masking in Parkinson's disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners' responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners' impressions of patient psychological attributes. Practitioners (N = 284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners' judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners' judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners' use of facial expressivity in clinical impression formation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. [Effect of oxygen tubing connection site on percutaneous oxygen partial pressure and percutaneous carbon dioxide partial pressure in patients with chronic obstructive pulmonary disease during noninvasive positive pressure ventilation].

    PubMed

    Mi, S; Zhang, L M

    2017-04-12

    Objective: We evaluated the effects of administering oxygen through nasal catheters inside the mask or through the mask on percutaneous oxygen partial pressure (PcO(2))and percutaneous carbon dioxide partial pressure (PcCO(2)) during noninvasive positive pressure ventilation (NPPV) to find a better way of administering oxygen, which could increase PcO(2) by increasing the inspired oxygen concentration. Methods: Ten healthy volunteers and 9 patients with chronic obstructive pulmonary disease complicated by type Ⅱ respiratory failure were included in this study. Oxygen was administered through a nasal catheter inside the mask or through the mask (oxygen flow was 3 and 5 L/min) during NPPV. PcO(2) and PcCO(2) were measured to evaluate the effects of administering oxygen through a nasal catheter inside the mask or through the mask, indirectly reflecting the effects of administering oxygen through nasal catheter inside the mask or through the mask on inspired oxygen concentration. Results: Compared to administering oxygen through the mask during NPPV, elevated PcO(2) was measured in administering oxygen through the nasal catheter inside the mask, and the differences were statistically significant ( P <0.05). At the same time, there was no significant change in PcCO(2) ( P >0.05). Conclusion: Administering oxygen through a nasal catheter inside the mask during NPPV increased PcO(2) by increasing the inspired oxygen concentration but did not increase PcCO(2). This method of administering oxygen could conserve oxygen and be suitable for family NPPV. Our results also provided theoretical basis for the development of new masks.

  15. Culture, Gender and Health Care Stigma: Practitioners’ Response to Facial Masking Experienced by People with Parkinson’s Disease

    PubMed Central

    Tickle-Degnen, Linda; Zebrowitz, Leslie A.; Ma, Hui-ing

    2011-01-01

    Facial masking in Parkinson’s disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners’ responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners’ impressions of patient psychological attributes. Practitioners (N=284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners’ judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners’ judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners’ use of facial expressivity in clinical impression formation. PMID:21664737

  16. Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak.

    PubMed

    Bakker, Jessie P; Neill, Alister M; Campbell, Angela J

    2012-09-01

    This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.

  17. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    PubMed

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  18. Randomized crossover trial of a pressure sensing visual feedback system to improve mask fitting in noninvasive ventilation.

    PubMed

    Brill, Anne-Kathrin; Moghal, Mohammad; Morrell, Mary J; Simonds, Anita K

    2017-10-01

    A good mask fit, avoiding air leaks and pressure effects on the skin are key elements for a successful noninvasive ventilation (NIV). However, delivering practical training for NIV is challenging, and it takes time to build experience and competency. This study investigated whether a pressure sensing system with real-time visual feedback improved mask fitting. During an NIV training session, 30 healthcare professionals (14 trained in mask fitting and 16 untrained) performed two mask fittings on the same healthy volunteer in a randomized order: one using standard mask-fitting procedures and one with additional visual feedback on mask pressure on the nasal bridge. Participants were required to achieve a mask fit with low mask pressure and minimal air leak (<10 L/min). Pressure exerted on the nasal bridge, perceived comfort of mask fit and staff- confidence were measured. Compared with standard mask fitting, a lower pressure was exerted on the nasal bridge using the feedback system (71.1 ± 17.6 mm Hg vs 63.2 ± 14.6 mm Hg, P < 0.001). Both untrained and trained healthcare professionals were able to reduce the pressure on the nasal bridge (74.5 ± 21.2 mm Hg vs 66.1 ± 17.4 mm Hg, P = 0.023 and 67 ± 12.1 mm Hg vs 60 ± 10.6 mm Hg, P = 0.002, respectively) using the feedback system and self-rated confidence increased in the untrained group. Real-time visual feedback using pressure sensing technology supported healthcare professionals during mask-fitting training, resulted in a lower pressure on the skin and better mask fit for the volunteer, with increased staff confidence. © 2017 Asian Pacific Society of Respirology.

  19. Multiple beam mask writers: an industry solution to the write time crisis

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.

    2010-09-01

    The semiconductor industry is under constant pressure to reduce production costs even as technology complexity increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which has added to the complexity of making masks through the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept mask write times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that $50M+ in non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development is a high risk for an individual supplier. The problem is compounded by a disconnect between the tool customer (the mask supplier) and the final mask customer that will bear the increased costs if a high speed writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed. Because SEMATECH's member companies strongly support a multiple beam technology for mask writers to reduce the write time and cost of 193 nm and EUV masks, SEMATECH plans to pursue an advanced mask writer program in 2011 and 2012. In 2010, efforts will focus on identifying a funding model to address the investment to develop such a technology.

  20. TNF-α modulates genome-wide redistribution of ΔNp63α/TAp73 and NF-κB cREL interactive binding on TP53 and AP-1 motifs to promote an oncogenic gene program in squamous cancer.

    PubMed

    Si, H; Lu, H; Yang, X; Mattox, A; Jang, M; Bian, Y; Sano, E; Viadiu, H; Yan, B; Yau, C; Ng, S; Lee, S K; Romano, R-A; Davis, S; Walker, R L; Xiao, W; Sun, H; Wei, L; Sinha, S; Benz, C C; Stuart, J M; Meltzer, P S; Van Waes, C; Chen, Z

    2016-11-03

    The Cancer Genome Atlas (TCGA) network study of 12 cancer types (PanCancer 12) revealed frequent mutation of TP53, and amplification and expression of related TP63 isoform ΔNp63 in squamous cancers. Further, aberrant expression of inflammatory genes and TP53/p63/p73 targets were detected in the PanCancer 12 project, reminiscent of gene programs comodulated by cREL/ΔNp63/TAp73 transcription factors we uncovered in head and neck squamous cell carcinomas (HNSCCs). However, how inflammatory gene signatures and cREL/p63/p73 targets are comodulated genome wide is unclear. Here, we examined how the inflammatory factor tumor necrosis factor-α (TNF-α) broadly modulates redistribution of cREL with ΔNp63α/TAp73 complexes and signatures genome wide in the HNSCC model UM-SCC46 using chromatin immunoprecipitation sequencing (ChIP-seq). TNF-α enhanced genome-wide co-occupancy of cREL with ΔNp63α on TP53/p63 sites, while unexpectedly promoting redistribution of TAp73 from TP53 to activator protein-1 (AP-1) sites. cREL, ΔNp63α and TAp73 binding and oligomerization on NF-κB-, TP53- or AP-1-specific sequences were independently validated by ChIP-qPCR (quantitative PCR), oligonucleotide-binding assays and analytical ultracentrifugation. Function of the binding activity was confirmed using TP53-, AP-1- and NF-κB-specific REs or p21, SERPINE1 and IL-6 promoter luciferase reporter activities. Concurrently, TNF-α regulated a broad gene network with cobinding activities for cREL, ΔNp63α and TAp73 observed upon array profiling and reverse transcription-PCR. Overlapping target gene signatures were observed in squamous cancer subsets and in inflamed skin of transgenic mice overexpressing ΔNp63α. Furthermore, multiple target genes identified in this study were linked to TP63 and TP73 activity and increased gene expression in large squamous cancer samples from PanCancer 12 TCGA by CircleMap. PARADIGM inferred pathway analysis revealed the network connection of TP63 and NF-κB complexes through an AP-1 hub, further supporting our findings. Thus, inflammatory cytokine TNF-α mediates genome-wide redistribution of the cREL/p63/p73, and AP-1 interactome, to diminish TAp73 tumor suppressor function and reciprocally activate NF-κB and AP-1 gene programs implicated in malignancy.

  1. Performance characteristics of constant-flow phase dilution oxygen mask designs for general aviation.

    DOT National Transportation Integrated Search

    1967-05-01

    The report describes evaluation of two prototype phase dilution rebreathing masks as compared to an open port rebreathing mask design. Human subjects wearing the prototype masks and engaged in three minute periods of rest and exercise were exposed to...

  2. Masking Strategies for Image Manifolds.

    PubMed

    Dadkhahi, Hamid; Duarte, Marco F

    2016-07-07

    We consider the problem of selecting an optimal mask for an image manifold, i.e., choosing a subset of the pixels of the image that preserves the manifold's geometric structure present in the original data. Such masking implements a form of compressive sensing through emerging imaging sensor platforms for which the power expense grows with the number of pixels acquired. Our goal is for the manifold learned from masked images to resemble its full image counterpart as closely as possible. More precisely, we show that one can indeed accurately learn an image manifold without having to consider a large majority of the image pixels. In doing so, we consider two masking methods that preserve the local and global geometric structure of the manifold, respectively. In each case, the process of finding the optimal masking pattern can be cast as a binary integer program, which is computationally expensive but can be approximated by a fast greedy algorithm. Numerical experiments show that the relevant manifold structure is preserved through the datadependent masking process, even for modest mask sizes.

  3. An interactive tool for gamut masking

    NASA Astrophysics Data System (ADS)

    Song, Ying; Lau, Cheryl; Süsstrunk, Sabine

    2014-02-01

    Artists often want to change the colors of an image to achieve a particular aesthetic goal. For example, they might limit colors to a warm or cool color scheme to create an image with a certain mood or feeling. Gamut masking is a technique that artists use to limit the set of colors they can paint with. They draw a mask over a color wheel and only use the hues within the mask. However, creating the color palette from the mask and applying the colors to the image requires skill. We propose an interactive tool for gamut masking that allows amateur artists to create an image with a desired mood or feeling. Our system extracts a 3D color gamut from the 2D user-drawn mask and maps the image to this gamut. The user can draw a different gamut mask or locally refine the image colors. Our voxel grid gamut representation allows us to represent gamuts of any shape, and our cluster-based image representation allows the user to change colors locally.

  4. High-sensitivity x-ray mask damage studies employing holographic gratings and phase-shifting interferometry

    NASA Astrophysics Data System (ADS)

    Hansen, Matthew E.; Cerrina, Franco

    1994-05-01

    A high-sensitivity holographic and interferometric metrology developed at the Center for X- ray Lithography (CXrL) has been employed to investigate in-plane distortions (IPD) produced in x-ray mask materials. This metrology has been applied to characterize damage to x-ray mask materials exposed to synchrotron radiation. X-ray mask damage and accelerated mask damage studies on silicon nitride and silicon carbide were conducted on the Aladdin ES-1 and ES-2 beamline exposure stations, respectively. Accumulated in-plane distortions due to x-ray irradiation were extracted from the incremental interferometric phase maps to yield IPD vs. dose curves for silicon nitride mask blanks. Silicon carbide mask blanks were subjected to accelerated mask damage in the high flux 2 mm X 2 mm beam of the ES-2 exposure station. An accelerated damage study of silicon carbide has shown no in-plane distortion for an accumulated dose of 800 kJ/cm2 with a measurement sensitivity of less than 5 nm.

  5. 2012 Mask Industry Survey

    NASA Astrophysics Data System (ADS)

    Malloy, Matt; Litt, Lloyd C.

    2012-11-01

    A survey supported by SEMATECH and administered by David Powell Consulting was sent to semiconductor industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. 2012 marks the 11th consecutive year for the mask industry survey. This year's survey and reporting structure are similar to those of the previous years with minor modifications based on feedback from past years and the need to collect additional data on key topics. Categories include general mask information, mask processing, data and write time, yield and yield loss, delivery times, and maintenance and returns. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. Results, initial observations, and key comparisons between the 2011 and 2012 survey responses are shown here, including multiple indications of a shift towards the manufacturing of higher end photomasks.

  6. Exploiting Small Leakages in Masks to Turn a Second-Order Attack into a First-Order Attack and Improved Rotating Substitution Box Masking with Linear Code Cosets.

    PubMed

    DeTrano, Alexander; Karimi, Naghmeh; Karri, Ramesh; Guo, Xiaofei; Carlet, Claude; Guilley, Sylvain

    2015-01-01

    Masking countermeasures, used to thwart side-channel attacks, have been shown to be vulnerable to mask-extraction attacks. State-of-the-art mask-extraction attacks on the Advanced Encryption Standard (AES) algorithm target S-Box recomputation schemes but have not been applied to scenarios where S-Boxes are precomputed offline. We propose an attack targeting precomputed S-Boxes stored in nonvolatile memory. Our attack targets AES implemented in software protected by a low entropy masking scheme and recovers the masks with 91% success rate. Recovering the secret key requires fewer power traces (in fact, by at least two orders of magnitude) compared to a classical second-order attack. Moreover, we show that this attack remains viable in a noisy environment or with a reduced number of leakage points. Eventually, we specify a method to enhance the countermeasure by selecting a suitable coset of the masks set.

  7. Exploiting Small Leakages in Masks to Turn a Second-Order Attack into a First-Order Attack and Improved Rotating Substitution Box Masking with Linear Code Cosets

    PubMed Central

    DeTrano, Alexander; Karimi, Naghmeh; Karri, Ramesh; Guo, Xiaofei; Carlet, Claude; Guilley, Sylvain

    2015-01-01

    Masking countermeasures, used to thwart side-channel attacks, have been shown to be vulnerable to mask-extraction attacks. State-of-the-art mask-extraction attacks on the Advanced Encryption Standard (AES) algorithm target S-Box recomputation schemes but have not been applied to scenarios where S-Boxes are precomputed offline. We propose an attack targeting precomputed S-Boxes stored in nonvolatile memory. Our attack targets AES implemented in software protected by a low entropy masking scheme and recovers the masks with 91% success rate. Recovering the secret key requires fewer power traces (in fact, by at least two orders of magnitude) compared to a classical second-order attack. Moreover, we show that this attack remains viable in a noisy environment or with a reduced number of leakage points. Eventually, we specify a method to enhance the countermeasure by selecting a suitable coset of the masks set. PMID:26491717

  8. Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

    NASA Technical Reports Server (NTRS)

    Robinson, E. L.; Fuller, C. A.

    1999-01-01

    Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

  9. Is masked priming modulated by memory load? A test of the automaticity of masked identity priming in lexical decision.

    PubMed

    Perea, Manuel; Marcet, Ana; Lozano, Mario; Gomez, Pablo

    2018-05-29

    One of the key assumptions of the masked priming lexical decision task (LDT) is that primes are processed without requiring attentional resources. Here, we tested this assumption by presenting a dual-task manipulation to increase memory load and measure the change in masked identity priming on the targets in the LDT. If masked priming does not require attentional resources, increased memory load should have no influence on the magnitude of the observed identity priming effects. We conducted two LDT experiments, using a within-subjects design, to investigate the effect of memory load (via a concurrent matching task Experiment 1 and a concurrent search task in Experiment 2) on masked identity priming. Results showed that the magnitude of masked identity priming on word targets was remarkably similar under high and low memory load. Thus, these experiments provide empirical evidence for the automaticity assumption of masked identity priming in the LDT.

  10. A Novel Anti-Influenza Copper Oxide Containing Respiratory Face Mask

    PubMed Central

    Borkow, Gadi; Zhou, Steve S.; Page, Tom; Gabbay, Jeffrey

    2010-01-01

    Background Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. Methodology/Principal Findings We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66±0.51 and 6.17±0.37 log10TCID50 of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (≤0.88 log10TCID50), while 4.67±1.35 log10TCID50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were ≤0.97±0.01 log10TCID50 and from the control masks 5.03±0.54 log10TCID50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Conclusions/Significance Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks. PMID:20592763

  11. Facile preparation of porous alumina through-hole masks for sputtering by two-layer anodization

    NASA Astrophysics Data System (ADS)

    Yanagishita, Takashi; Masuda, Hideki

    2016-08-01

    Highly ordered porous alumina through-hole masks were fabricated on a substrate by combining two-layer anodization with subsequent through-holing by selective etching. This process allowed the fabrication of porous alumina masks without an increase in pore size during the etching performed for through-holing. Additionally, the process contributed to improved operability in the setting of the masks on substrates because the second anodizing layer acts as a supporting layer for the handling of the mask. The fabrication of ordered Au nanodot arrays was demonstrated as an example application of the through-hole masks obtained by the present process.

  12. Accuracy and performance of 3D mask models in optical projection lithography

    NASA Astrophysics Data System (ADS)

    Agudelo, Viviana; Evanschitzky, Peter; Erdmann, Andreas; Fühner, Tim; Shao, Feng; Limmer, Steffen; Fey, Dietmar

    2011-04-01

    Different mask models have been compared: rigorous electromagnetic field (EMF) modeling, rigorous EMF modeling with decomposition techniques and the thin mask approach (Kirchhoff approach) to simulate optical diffraction from different mask patterns in projection systems for lithography. In addition, each rigorous model was tested for two different formulations for partially coherent imaging: The Hopkins assumption and rigorous simulation of mask diffraction orders for multiple illumination angles. The aim of this work is to closely approximate results of the rigorous EMF method by the thin mask model enhanced with pupil filtering techniques. The validity of this approach for different feature sizes, shapes and illumination conditions is investigated.

  13. Masks For Deposition Of Aspherical Optical Surfaces

    NASA Technical Reports Server (NTRS)

    Rogers, John R.; Martin, John D.

    1992-01-01

    Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

  14. Self-masking: Listening during vocalization. Normal hearing.

    PubMed

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  15. Reusable High Aspect Ratio 3-D Nickel Shadow Mask

    PubMed Central

    Shandhi, M.M.H.; Leber, M.; Hogan, A.; Warren, D.J.; Bhandari, R.; Negi, S.

    2017-01-01

    Shadow Mask technology has been used over the years for resistless patterning and to pattern on unconventional surfaces, fragile substrate and biomaterial. In this work, we are presenting a novel method to fabricate high aspect ratio (15:1) three-dimensional (3D) Nickel (Ni) shadow mask with vertical pattern length and width of 1.2 mm and 40 μm respectively. The Ni shadow mask is 1.5 mm tall and 100 μm wide at the base. The aspect ratio of the shadow mask is 15. Ni shadow mask is mechanically robust and hence easy to handle. It is also reusable and used to pattern the sidewalls of unconventional and complex 3D geometries such as microneedles or neural electrodes (such as the Utah array). The standard Utah array has 100 active sites at the tip of the shaft. Using the proposed high aspect ratio Ni shadow mask, the Utah array can accommodate 300 active sites, 200 of which will be along and around the shaft. The robust Ni shadow mask is fabricated using laser patterning and electroplating techniques. The use of Ni 3D shadow mask will lower the fabrication cost, complexity and time for patterning out-of-plane structures. PMID:29056835

  16. Face mask use by patients in primary care.

    PubMed

    Tischendorf, Jessica S; Temte, Jonathan L

    2012-02-01

    Face masks are recommended for patients with respiratory symptoms to reduce influenza transmission. Little knowledge exists regarding actual utilization and acceptance of face masks in primary care. Compare distribution of face masks to clinic and community trends in respiratory infection (RI) and influenza-like illness (ILI); estimate the annual need for face masks in primary care. Retrospective observational study of practice data from a 31-week period starting in October 2009. Family practice clinic in Madison, Wis. Patients with fever, cough, or other respiratory symptoms as evaluated by reception staff. Age, sex, and weekly counts of individuals receiving a face mask, as well as counts of RI and ILI patients based on ICD-9 coding from 27 statewide clinics. Face mask counts were 80% of RI counts for the clinic and reflected the demographics of the clinic population. Distribution was correlated to prevalence of RI (R = 0.783, P < 0.001) and ILI (R = 0.632, P < 0.001). Annually, 8% of clinic visits were for RI. The high percentage of face mask use among RI patients reflects the feasibility of this intervention to help control influenza transmission in a primary care setting. Using the present data, clinics can estimate the annual need for face masks.

  17. Mask industry assessment: 2008

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2008-10-01

    Microelectronics industry leaders routinely name the cost and cycle time of mask technology and mask supply as top critical issues. A survey was created with support from SEMATECH and administered by David Powell Consulting to gather information about the mask industry as an objective assessment of its overall condition. The survey is designed with the input of semiconductor company mask technologists, merchant mask suppliers, and industry equipment makers. This year's assessment is the seventh in the current series of annual reports. With ongoing industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments pertaining to critical path issues. This year's survey is basically the same as the 2005 through 2007 surveys. Questions are grouped into categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that create a detailed profile of both the business and technical status of the critical mask industry.

  18. Mask industry assessment trend analysis: 2010

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2010-05-01

    Microelectronics industry leaders consistently cite the cost and cycle time of mask technology and mask supply as top critical issues. A survey was designed with input from semiconductor company mask technologists and merchant mask suppliers and support from SEMATECH to gather information about the mask industry as an objective assessment of its overall condition. This year's assessment was the eighth in the current series of annual reports. Its data were presented in detail at BACUS, and the detailed trend analysis is presented at EMLC. With continued industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. Its results will be used to guide future investments on critical path issues. This year's survey is basically the same as the surveys in 2005 through 2009. Questions are grouped into six categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that creates a detailed profile of both the business and technical status of the critical mask industry.

  19. The 2002 to 2010 mask survey trend analysis

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Chan, David

    2011-03-01

    Microelectronics industry leaders consistently cite the cost and cycle time of mask technology and mask supply as top critical issues. A survey was designed with input from semiconductor company mask technologists and merchant mask suppliers and support from SEMATECH to gather information about the mask industry as an objective assessment of its overall condition. This year's assessment was the ninth in the current series of annual reports. Its data were presented in detail at BACUS, and the detailed trend analysis is presented at EMLC. With continued industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. Results will be used to guide future investments in critical path issues. This year's survey is basically the same as the 2005 through 2010 surveys. Questions are grouped into six categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category are multiple questions that ultimately create a detailed profile of both the business and technical status of the critical mask industry.

  20. Auditory processing efficiency deficits in children with developmental language impairments

    NASA Astrophysics Data System (ADS)

    Hartley, Douglas E. H.; Moore, David R.

    2002-12-01

    The ``temporal processing hypothesis'' suggests that individuals with specific language impairments (SLIs) and dyslexia have severe deficits in processing rapidly presented or brief sensory information, both within the auditory and visual domains. This hypothesis has been supported through evidence that language-impaired individuals have excess auditory backward masking. This paper presents an analysis of masking results from several studies in terms of a model of temporal resolution. Results from this modeling suggest that the masking results can be better explained by an ``auditory efficiency'' hypothesis. If impaired or immature listeners have a normal temporal window, but require a higher signal-to-noise level (poor processing efficiency), this hypothesis predicts the observed small deficits in the simultaneous masking task, and the much larger deficits in backward and forward masking tasks amongst those listeners. The difference in performance on these masking tasks is predictable from the compressive nonlinearity of the basilar membrane. The model also correctly predicts that backward masking (i) is more prone to training effects, (ii) has greater inter- and intrasubject variability, and (iii) increases less with masker level than do other masking tasks. These findings provide a new perspective on the mechanisms underlying communication disorders and auditory masking.

Top