Low-cost compact thermal imaging sensors for body temperature measurement
NASA Astrophysics Data System (ADS)
Han, Myung-Soo; Han, Seok Man; Kim, Hyo Jin; Shin, Jae Chul; Ahn, Mi Sook; Kim, Hyung Won; Han, Yong Hee
2013-06-01
This paper presents a 32x32 microbolometer thermal imaging sensor for human body temperature measurement. Waferlevel vacuum packaging technology allows us to get a low cost and compact imaging sensor chip. The microbolometer uses V-W-O film as sensing material and ROIC has been designed 0.35-um CMOS process in UMC. A thermal image of a human face and a hand using f/1 lens convinces that it has a potential of human body temperature for commercial use.
Liu, I-Chen; Chen, Pin-Chuan; Chau, Lai-Kwan; Chang, Guo-En
2018-01-08
We propose and develop an intensity-detection-based refractive-index (RI) sensor for low-cost, rapid RI sensing. The sensor is composed of a polymer bent ridge waveguide (BRWG) structure on a low-cost glass substrate and is integrated with a microfluidic channel. Different-RI solutions flowing through the BRWG sensing region induce output optical power variations caused by optical bend losses, enabling simple and real-time RI detection. Additionally, the sensors are fabricated using rapid and cost-effective vacuum-less processes, attaining the low cost and high throughput required for mass production. A good RI solution of 5.31 10 -4 × RIU -1 is achieved from the RI experiments. This study demonstrates mass-producible and compact RI sensors for rapid and sensitive chemical analysis and biomedical sensing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Yufei, E-mail: mayufei@hit.edu.cn; Post-doctoral Mobile Station of Power Engineering and Engineering Thermophysics, Harbin Institute of Technology, Harbin 150001; He, Ying
An ultra compact all-fiber quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor using quartz tuning fork (QTF) with a low resonance frequency of 30.72 kHz was demonstrated. Such a sensor architecture has the advantages of easier optical alignment, lower insertion loss, lower cost, and more compact compared with a conventional QEPAS sensor using discrete optical components for laser delivery and coupling to the QTF. A fiber beam splitter and three QTFs were employed to perform multi-point detection and demonstrated the potential of spatially resolved measurements.
Air Sensor Toolbox for Citizen Scientists
EPA’s Air Sensor Toolbox provides information and guidance on new low-cost compact technologies for measuring air quality. It provides information to help citizens more effectively and accurately collect air quality data in their community.
Air Sensor Toolbox: Resources and Funding
EPA’s Air Sensor Toolbox provides information and guidance on new low-cost compact technologies for measuring air quality. It provides information to help citizens more effectively and accurately collect air quality data in their community.
Camera-based micro interferometer for distance sensing
NASA Astrophysics Data System (ADS)
Will, Matthias; Schädel, Martin; Ortlepp, Thomas
2017-12-01
Interference of light provides a high precision, non-contact and fast method for measurement method for distances. Therefore this technology dominates in high precision systems. However, in the field of compact sensors capacitive, resistive or inductive methods dominates. The reason is, that the interferometric system has to be precise adjusted and needs a high mechanical stability. As a result, we have usual high-priced complex systems not suitable in the field of compact sensors. To overcome these we developed a new concept for a very small interferometric sensing setup. We combine a miniaturized laser unit, a low cost pixel detector and machine vision routines to realize a demonstrator for a Michelson type micro interferometer. We demonstrate a low cost sensor smaller 1cm3 including all electronics and demonstrate distance sensing up to 30 cm and resolution in nm range.
A low cost PSD-based monocular motion capture system
NASA Astrophysics Data System (ADS)
Ryu, Young Kee; Oh, Choonsuk
2007-10-01
This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system is compact, low-cost, and only requires a one-time calibration at the factory. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The PSD sensor is placed in the focal plane of a wide-angle lens. The micro-controller calculates the 3D position of the markers using only the measured intensity and the 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system has the advantages of the compact size, the low cost, the easy installation, and the high frame rates to be suitable for high speed motion tracking in games.
Rabani, Amir
2016-01-01
The market for process instruments generally requires low cost devices that are robust, small in size, portable, and usable in-plant. Ultrasonic torsional guided wave sensors have received much attention by researchers for measurement of viscosity and/or density of fluids in recent years. The supporting electronic systems for these sensors providing many different settings of sine-wave signals are bulky and expensive. In contrast, a system based on bursts of square waves instead of sine waves would have a considerable advantage in that respect and could be built using simple integrated circuits at a cost that is orders of magnitude lower than for a windowed sine wave device. This paper explores the possibility of using square wave bursts as the driving signal source for the ultrasonic torsional guided wave viscosity sensor. A simple design of a compact and fully automatic analogue square wave front-end for the sensor is also proposed. The successful operation of the system is demonstrated by using the sensor for measuring the viscosity in a representative fluid. This work provides the basis for design and manufacture of low cost compact standalone ultrasonic guided wave sensors and enlightens the possibility of using coded excitation techniques utilising square wave sequences in such applications. PMID:27754324
Rabani, Amir
2016-10-12
The market for process instruments generally requires low cost devices that are robust, small in size, portable, and usable in-plant. Ultrasonic torsional guided wave sensors have received much attention by researchers for measurement of viscosity and/or density of fluids in recent years. The supporting electronic systems for these sensors providing many different settings of sine-wave signals are bulky and expensive. In contrast, a system based on bursts of square waves instead of sine waves would have a considerable advantage in that respect and could be built using simple integrated circuits at a cost that is orders of magnitude lower than for a windowed sine wave device. This paper explores the possibility of using square wave bursts as the driving signal source for the ultrasonic torsional guided wave viscosity sensor. A simple design of a compact and fully automatic analogue square wave front-end for the sensor is also proposed. The successful operation of the system is demonstrated by using the sensor for measuring the viscosity in a representative fluid. This work provides the basis for design and manufacture of low cost compact standalone ultrasonic guided wave sensors and enlightens the possibility of using coded excitation techniques utilising square wave sequences in such applications.
Construction and Characterization of a Compact, Portable, Low-Cost Colorimeter for the Chemistry Lab
ERIC Educational Resources Information Center
Clippard, Carrie M.; Hughes, William; Chohan, Balwant S.; Sykes, Danny G.
2016-01-01
A low-cost and portable colorimeter was constructed featuring a low-voltage programmable color light sensor-to-frequency converter, a CMOS 8-bit microcontroller, and an LCD display. The instrument has successfully facilitated the introduction and application of spectroscopy to groups of middle school, high school, and undergraduate students. A…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Philip
The research objective of this project is to design and demonstrate a low-cost, compact, easy-to-deploy, maintenance-free sensor node technology, and a network of such sensors, which enable the monitoring of multiphysical parameters and can transform today’s ordinary buildings into smart buildings with environmental awareness. We develop the sensor node and network via engineering and integration of existing technologies, including high-efficiency mechanical energy harvesting, and ultralow-power integrated circuits (ICs) for sensing and wireless communication. Through integration and innovative power management via specifically designed low-power control circuits for wireless sensing applications, and tailoring energy-harvesting components to indoor applications, the target products willmore » have smaller volume, higher efficiency, and much lower cost (in both manufacturing and maintenance) than the baseline technology. Our development and commercialization objective is to create prototypes for our target products under the CWRU-Intwine collaboration.« less
Compact, diode-pumped, solid-state lasers for next generation defence and security sensors
NASA Astrophysics Data System (ADS)
Silver, M.; Lee, S. T.; Borthwick, A.; McRae, I.; Jackson, D.; Alexander, W.
2015-06-01
Low-cost semiconductor laser diode pump sources have made a dramatic impact in sectors such as advanced manufacturing. They are now disrupting other sectors, such as defence and security (D&S), where Thales UK is a manufacturer of sensor systems for application on land, sea, air and man portable. In this talk, we will first give an overview of the market trends and challenges in the D&S sector. Then we will illustrate how low cost pump diodes are enabling new directions in D&S sensors, by describing two diode pumped, solid- state laser products currently under development at Thales UK. The first is a new generation of Laser Target Designators (LTD) that are used to identify targets for the secure guiding of munitions. Current systems are bulky, expensive and require large battery packs to operate. The advent of low cost diode technology, merged with our novel solid-state laser design, has created a designator that will be the smallest, lowest cost, STANAG compatible laser designator on the market. The LTD delivers greater that 50mJ per pulse up to 20Hz, and has compact dimensions of 125×70×55mm. Secondly, we describe an ultra-compact, eye-safe, solid-state laser rangefinder (LRF) with reduced size, weight and power consumption compared to existing products. The LRF measures 100×55×34mm, weighs 200g, and can range to greater than 10km with a single laser shot and at a reprate of 1Hz. This also leverages off advances in laser pump diodes, but also utilises low cost, high reliability, packaging technology commonly found in the telecoms sector. As is common in the D&S sector, the products are designed to work in extreme environments, such as wide temperature range (-40 to +71°C) and high levels of shock and vibration. These disruptive products enable next- generation laser sensors such as rangefinders, target designators and active illuminated imagers.
Antolín, Diego; Calvo, Belén; Martínez, Pedro A.
2017-01-01
This paper presents a low-cost high-efficiency solar energy harvesting system to power outdoor wireless sensor nodes. It is based on a Voltage Open Circuit (VOC) algorithm that estimates the open-circuit voltage by means of a multilayer perceptron neural network model trained using local experimental characterization data, which are acquired through a novel low cost characterization system incorporated into the deployed node. Both units—characterization and modelling—are controlled by the same low-cost microcontroller, providing a complete solution which can be understood as a virtual pilot cell, with identical characteristics to those of the specific small solar cell installed on the sensor node, that besides allows an easy adaptation to changes in the actual environmental conditions, panel aging, etc. Experimental comparison to a classical pilot panel based VOC algorithm show better efficiency under the same tested conditions. PMID:28777330
Antolín, Diego; Medrano, Nicolás; Calvo, Belén; Martínez, Pedro A
2017-08-04
This paper presents a low-cost high-efficiency solar energy harvesting system to power outdoor wireless sensor nodes. It is based on a Voltage Open Circuit (VOC) algorithm that estimates the open-circuit voltage by means of a multilayer perceptron neural network model trained using local experimental characterization data, which are acquired through a novel low cost characterization system incorporated into the deployed node. Both units-characterization and modelling-are controlled by the same low-cost microcontroller, providing a complete solution which can be understood as a virtual pilot cell, with identical characteristics to those of the specific small solar cell installed on the sensor node, that besides allows an easy adaptation to changes in the actual environmental conditions, panel aging, etc. Experimental comparison to a classical pilot panel based VOC algorithm show better efficiency under the same tested conditions.
Revolutionize Situational Awareness in Emergencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hehlen, Markus Peter
This report describes an integrated system that provides real-time actionable information to first responders. LANL will integrate three technologies to form an advanced predictive real-time sensor network including compact chemical and wind sensor sin low cost rugged package for outdoor installation; flexible robust communication architecture linking sensors in near-real time to globally accessible servers; and the QUIC code which predicts contamination transport and dispersal in urban environments in near real time.
Lensless transport-of-intensity phase microscopy and tomography with a color LED matrix
NASA Astrophysics Data System (ADS)
Zuo, Chao; Sun, Jiasong; Zhang, Jialin; Hu, Yan; Chen, Qian
2015-07-01
We demonstrate lens-less quantitative phase microscopy and diffraction tomography based on a compact on-chip platform, using only a CMOS image sensor and a programmable color LED array. Based on multi-wavelength transport-of- intensity phase retrieval and multi-angle illumination diffraction tomography, this platform offers high quality, depth resolved images with a lateral resolution of ˜3.7μm and an axial resolution of ˜5μm, over wide large imaging FOV of 24mm2. The resolution and FOV can be further improved by using a larger image sensors with small pixels straightforwardly. This compact, low-cost, robust, portable platform with a decent imaging performance may offer a cost-effective tool for telemedicine needs, or for reducing health care costs for point-of-care diagnostics in resource-limited environments.
Microphotonic devices for compact planar lightwave circuits and sensor systems
NASA Astrophysics Data System (ADS)
Cardenas Gonzalez, Jaime
2005-07-01
Higher levels of integration in planar lightwave circuits and sensor systems can reduce fabrication costs and broaden viable applications for optical network and sensor systems. For example, increased integration and functionality can lead to sensor systems that are compact enough for easy transport, rugged enough for field applications, and sensitive enough even for laboratory applications. On the other hand, more functional and compact planar lightwave circuits can make optical networks components less expensive for the metro and access markets in urban areas and allow penetration of fiber to the home. Thus, there is an important area of opportunity for increased integration to provide low cost, compact solutions in both network components and sensor systems. In this dissertation, a novel splitting structure for microcantilever deflection detection is introduced. The splitting structure is designed so that its splitting ratio is dependent on the vertical position of the microcantilever. With this structure, microcantilevers sensitized to detect different analytes or biological agents can be integrated into an array on a single chip. Additionally, the integration of a depolarizer into the optoelectronic integrated circuit in an interferometric fiber optic gyroscope is presented as a means for cost reduction. The savings come in avoiding labor intensive fiber pigtailing steps by permitting batch fabrication of these components. In particular, this dissertation focuses on the design of the waveguides and polarization rotator, and the impact of imperfect components on the performance of the depolarizer. In the area of planar lightwave circuits, this dissertation presents the development of a fabrication process for single air interface bends (SAIBs). SAIBs can increase integration by reducing the area necessary to make a waveguide bend. Fabrication and measurement of a 45° SAIB with a bend efficiency of 93.4% for TM polarization and 92.7% for TE polarization are presented.
2D scanning Rotman lens structure for smart collision avoidance sensors
NASA Astrophysics Data System (ADS)
Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek
2004-03-01
Although electronically scanned antenna arrays can provide effective mm-wave search radar sensors, their high cost and complexity are leading to the consideration of alternative beam-forming arrangements. Rotman lenses offer a compact, rugged, reliable, alternative solution. This paper considers the design of a microstrip based Rotman lens for high-resolution, frequency-controlled scanning applications. Its implementation in microstrip is attractive because this technology is low-cost, conformal, and lightweight. A sensor designed for operation at 77 GHz is presented and an ~80° azimuthal scan over a 30 GHz bandwidth is demonstrated.
NASA Astrophysics Data System (ADS)
Deng, Shijie; Doherty, William; McAuliffe, Michael AP; Salaj-Kosla, Urszula; Lewis, Liam; Huyet, Guillaume
2016-06-01
A low-cost and portable optical chemical sensor based ammonia sensing system that is capable of detecting dissolved ammonia up to 5 ppm is presented. In the system, an optical chemical sensor is designed and fabricated for sensing dissolved ammonia concentrations. The sensor uses eosin as the fluorescence dye which is immobilized on the glass substrate by a gas-permeable protection layer. A compact module is developed to hold the optical components, and a battery powered micro-controller system is designed to read out and process the data measured. The system operates without the requirement of laboratory instruments that makes it cost effective and highly portable. Moreover, the calculated results in the system can be transmitted to a PC wirelessly, which allows the remote and real-time monitoring of dissolved ammonia.
Color sensor and neural processor on one chip
NASA Astrophysics Data System (ADS)
Fiesler, Emile; Campbell, Shannon R.; Kempem, Lother; Duong, Tuan A.
1998-10-01
Low-cost, compact, and robust color sensor that can operate in real-time under various environmental conditions can benefit many applications, including quality control, chemical sensing, food production, medical diagnostics, energy conservation, monitoring of hazardous waste, and recycling. Unfortunately, existing color sensor are either bulky and expensive or do not provide the required speed and accuracy. In this publication we describe the design of an accurate real-time color classification sensor, together with preprocessing and a subsequent neural network processor integrated on a single complementary metal oxide semiconductor (CMOS) integrated circuit. This one-chip sensor and information processor will be low in cost, robust, and mass-producible using standard commercial CMOS processes. The performance of the chip and the feasibility of its manufacturing is proven through computer simulations based on CMOS hardware parameters. Comparisons with competing methodologies show a significantly higher performance for our device.
Miniature Wide-Angle Lens for Small-Pixel Electronic Camera
NASA Technical Reports Server (NTRS)
Mouroulils, Pantazis; Blazejewski, Edward
2009-01-01
A proposed wideangle lens is shown that would be especially well suited for an electronic camera in which the focal plane is occupied by an image sensor that has small pixels. The design of the lens is intended to satisfy requirements for compactness, high image quality, and reasonably low cost, while addressing issues peculiar to the operation of small-pixel image sensors. Hence, this design is expected to enable the development of a new generation of compact, high-performance electronic cameras. The lens example shown has a 60 degree field of view and a relative aperture (f-number) of 3.2. The main issues affecting the design are also shown.
Asymmetric structured microfiber-based temperature sensor
NASA Astrophysics Data System (ADS)
Xian, Pei; Feng, Guoying; Dai, Shenyu; Zhou, Shouhuan
2017-04-01
A temperature sensor formed by a cascaded sphere and an abrupt taper, together in a standard single-mode fiber, was developed. The dip of the measured spectrum signal shifted obviously when the surrounding temperature changed. Measurement sensitivity to 18.36 pm/°C was shown with the surrounding temperature ranging from 35°C to 395°C. Due to its compact size and all-fiber configuration, the proposed sensor has the advantages of simplicity and low-cost fabrication, thus the device would find potential applications in sensing fields.
Latest developments for low-power infrared laser-based trace gas sensors for sensor networks
NASA Astrophysics Data System (ADS)
So, Stephen; Thomazy, David; Wang, Wen; Marchat, Oscar; Wysocki, Gerard
2011-09-01
Academic and industrial researchers require ultra-low power, compact laser based trace-gas sensor systems for the most demanding environmental and space-borne applications. Here the latest results from research projects addressing these applications will be discussed: 1) an ultra-compact CO2 sensor based on a continuous wave quantum cascade laser, 2) an ultra-sensitive Faraday rotation spectrometer for O2 detection, 3) a fully ruggedized compact and low-power laser spectrometer, and 4) a novel non-paraxial nonthin multipass cell. Preliminary tests and projection for performance of future sensors based on this technology is presented.
Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C
2012-01-01
Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.
NASA Astrophysics Data System (ADS)
Azhar, M.; Mandon, J.; Neerincx, A. H.; Liu, Z.; Mink, J.; Merkus, P. J. F. M.; Cristescu, S. M.; Harren, F. J. M.
2017-11-01
A compact, cost-effective sensor is developed for detection of hydrogen cyanide (HCN) in exhaled breath within seconds. For this, an off-axis integrated cavity output spectroscopy setup is combined with a widely tunable compact near-infrared laser (tunability 1527-1564 nm). For HCN a detection sensitivity has been obtained of 8 ppbv in nitrogen (within 1 s), equal to a noise equivalent absorption sensitivity of 1.9 × 10-9 cm-1 Hz-1/2. With this sensor we demonstrated the presence of HCN in exhaled breath; its detection could be a good indicator for bacterial lung infection. Due to its compact, cost-effective and user-friendly design, this laser-based sensor has the potential to be implemented in future clinical applications.
Compact Embedded Wireless Sensor-Based Monitoring of Concrete Curing.
Cabezas, Joaquín; Sánchez-Rodríguez, Trinidad; Gómez-Galán, Juan Antonio; Cifuentes, Héctor; González Carvajal, Ramón
2018-03-15
This work presents the design, construction and testing of a new embedded sensor system for monitoring concrete curing. A specific mote has been implemented to withstand the aggressive environment without affecting the measured variables. The system also includes a real-time monitoring application operating from a remote computer placed in a central location. The testing was done in two phases: the first in the laboratory, to validate the functional requirements of the developed devices; and the second on civil works to evaluate the functional features of the devices, such as range, robustness and flexibility. The devices were successfully implemented resulting in a low cost, highly reliable, compact and non-destructive solution.
Compact Embedded Wireless Sensor-Based Monitoring of Concrete Curing
Cabezas, Joaquín; Sánchez-Rodríguez, Trinidad; González Carvajal, Ramón
2018-01-01
This work presents the design, construction and testing of a new embedded sensor system for monitoring concrete curing. A specific mote has been implemented to withstand the aggressive environment without affecting the measured variables. The system also includes a real-time monitoring application operating from a remote computer placed in a central location. The testing was done in two phases: the first in the laboratory, to validate the functional requirements of the developed devices; and the second on civil works to evaluate the functional features of the devices, such as range, robustness and flexibility. The devices were successfully implemented resulting in a low cost, highly reliable, compact and non-destructive solution. PMID:29543765
Fletcher, Richard Ribon; Dobson, Kelly; Goodwin, Matthew S; Eydgahi, Hoda; Wilder-Smith, Oliver; Fernholz, David; Kuboyama, Yuta; Hedman, Elliott Bruce; Poh, Ming-Zher; Picard, Rosalind W
2010-03-01
Widespread use of affective sensing in healthcare applications has been limited due to several practical factors, such as lack of comfortable wearable sensors, lack of wireless standards, and lack of low-power affordable hardware. In this paper, we present a new low-cost, low-power wireless sensor platform implemented using the IEEE 802.15.4 wireless standard, and describe the design of compact wearable sensors for long-term measurement of electrodermal activity, temperature, motor activity, and photoplethysmography. We also illustrate the use of this new technology for continuous long-term monitoring of autonomic nervous system and motion data from active infants, children, and adults. We describe several new applications enabled by this system, discuss two specific wearable designs for the wrist and foot, and present sample data.
Rugged, Low Cost, Environmental Sensors for a Turbulent World
NASA Astrophysics Data System (ADS)
Schulz, B.; Sandell, C. T.; Wickert, A. D.
2017-12-01
Ongoing scientific research and resource management require a diverse range of high-quality and low-cost sensors to maximize the number and type of measurements that can be obtained. To accomplish this, we have developed a series of diversified sensors for common environmental applications. The TP-DownHole is an ultra-compact temperature and pressure sensor designed for use in CMT (Continuous Multi-channel Tubing) multi-level wells. Its 1 mm water depth resolution, 30 cm altitude resolution, and rugged design make it ideal for both water level measurements and monitoring barometric pressure and associated temperature changes. The TP-DownHole sensor has also been incorporated into a self-contained, fully independent data recorder for extreme and remote environments. This device (the TP-Solo) is based around the TP-DownHole design, but has self-contained power and data storage and is designed to collect data independently for up to 6 months (logging at once an hour), creating a specialized tool for extreme environment data collection. To gather spectral information, we have also developed a very low cost photodiode-based Lux sensor to measure spectral irradiance; while this does not measure the entire solar radiation spectrum, simple modeling to rescale the remainder of the solar spectrum makes this a cost-effective alternative to a thermopile pyranometer. Lastly, we have developed an instrumentation amplifier which is designed to interface a wide range of sensitive instruments to common data logging systems, such as thermopile pyranometers, thermocouples, and many other analog output sensors. These three instruments are the first in a diverse family aimed to give researchers a set of powerful and low-cost tools for environmental instrumentation.
Bastos, Ana R; Vicente, Carlos M S; Oliveira-Silva, Rui; Silva, Nuno J O; Tacão, Marta; Costa, João P da; Lima, Mário; André, Paulo S; Ferreira, Rute A S
2018-03-12
The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10 -4 RIU) and limit of detection (LOD = 2 × 10 -4 ) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells.
Fiber sensors for molecular detection
NASA Astrophysics Data System (ADS)
Gu, Claire; Yang, Xuan; Zhang, Jin; Newhouse, Rebecca; Cao, Liangcai
2010-11-01
The demand on sensors for detecting chemical and biological agents is greater than ever before, including medical, environmental, food safety, military, and security applications. At present, most detection or sensing techniques tend to be either non-molecular specific, bulky, expensive, relatively inaccurate, or unable to provide real time data. Clearly, alternative sensing technologies are urgently needed. Recently, we have been working to develop a compact fiber optic surface enhanced Raman scattering (SERS) sensor system that integrates various novel ideas to achieve compactness, high sensitivity and consistency, molecular specificity, and automatic preliminary identification capabilities. The unique sensor architecture is expected to bring SERS sensors to practical applications due to a combination of 1) novel SERS substrates that provide the high sensitivity and consistency, molecular specificity, and applicability to a wide range of compounds; 2) a unique hollow core optical fiber probe with double SERS substrate structure that provides the compactness, reliability, low cost, and ease of sampling; and 3) an innovative matched spectral filter set that provides automatic preliminary molecule identification. In this paper, we will review the principle of operation and some of the important milestones of fiber SERS sensor development with emphasis on our recent work to integrate photonic crystal fiber SERS probes with a portable Raman spectrometer and to demonstrate a matched spectral filter for molecule identification.
Air Sensor Toolbox provides information to citizen scientists, researchers and developers interested in learning more about new lower-cost compact air sensor technologies and tools for measuring air quality.
The Photoluminescence of a Fluorescent Lamp: Didactic Experiments on the Exponential Decay
ERIC Educational Resources Information Center
Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano
2017-01-01
The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras,…
High-Temperature Piezoelectric Sensing
Jiang, Xiaoning; Kim, Kyungrim; Zhang, Shujun; Johnson, Joseph; Salazar, Giovanni
2014-01-01
Piezoelectric sensing is of increasing interest for high-temperature applications in aerospace, automotive, power plants and material processing due to its low cost, compact sensor size and simple signal conditioning, in comparison with other high-temperature sensing techniques. This paper presented an overview of high-temperature piezoelectric sensing techniques. Firstly, different types of high-temperature piezoelectric single crystals, electrode materials, and their pros and cons are discussed. Secondly, recent work on high-temperature piezoelectric sensors including accelerometer, surface acoustic wave sensor, ultrasound transducer, acoustic emission sensor, gas sensor, and pressure sensor for temperatures up to 1,250 °C were reviewed. Finally, discussions of existing challenges and future work for high-temperature piezoelectric sensing are presented. PMID:24361928
NASA Astrophysics Data System (ADS)
Adams, J. D.; Rogers, B.; Whitten, R.
2005-05-01
The remarkable sensitivity, compactness, low cost, low power-consumption, scalability, and versatility of microcantilever sensors make this technology among the most promising solutions for detection of chemical and biological agents, as well as explosives. The University of Nevada, Reno, and Nevada Nanotech Systems, Inc (NNTS) are currently developing a microcantilever-based detection system that will measure trace concentrations of explosives, toxic chemicals, and biological agents in air. A baseline sensor unit design that includes the sensor array, electronics, power supply and air handling has been created and preliminary demonstrations of the microcantilever platform have been conducted. The envisioned device would measure about two cubic inches, run on a small watch battery and cost a few hundred dollars. The device could be operated by untrained law enforcement personnel. Microcantilever-based devices could be used to "sniff out" illegal and/or hazardous chemical and biological agents in high traffic public areas, or be packaged as a compact, low-power system used to monitor cargo in shipping containers. Among the best detectors for such applications at present is the dog, an animal which is expensive, requires significant training and can only be made to work for limited time periods. The public is already accustomed to explosives and metal detection systems in airports and other public venues, making the integration of the proposed device into such security protocols straightforward.
NASA Astrophysics Data System (ADS)
Holasek, Rick; Nakanishi, Keith; Ziph-Schatzberg, Leah; Santman, Jeff; Woodman, Patrick; Zacaroli, Richard; Wiggins, Richard
2017-04-01
Hyperspectral imaging (HSI) has been used for over two decades in laboratory research, academic, environmental and defense applications. In more recent time, HSI has started to be adopted for commercial applications in machine vision, conservation, resource exploration, and precision agriculture, to name just a few of the economically viable uses for the technology. Corning Incorporated (Corning) has been developing and manufacturing HSI sensors, sensor systems, and sensor optical engines, as well as HSI sensor components such as gratings and slits for over a decade and a half. This depth of experience and technological breadth has allowed Corning to design and develop unique HSI spectrometers with an unprecedented combination of high performance, low cost and low Size, Weight, and Power (SWaP). These sensors and sensor systems are offered with wavelength coverage ranges from the visible to the Long Wave Infrared (LWIR). The extremely low SWaP of Corning's HSI sensors and sensor systems enables their deployment using limited payload platforms such as small unmanned aerial vehicles (UAVs). This paper discusses use of the Corning patented monolithic design Offner spectrometer, the microHSI™, to build a highly compact 400-1000 nm HSI sensor in combination with a small Inertial Navigation System (INS) and micro-computer to make a complete turn-key airborne remote sensing payload. This Selectable Hyperspectral Airborne Remote sensing Kit (SHARK) has industry leading SWaP (1.5 lbs) at a disruptively low price due, in large part, to Corning's ability to manufacture the monolithic spectrometer out of polymers (i.e. plastic) and therefore reduce manufacturing costs considerably. The other factor in lowering costs is Corning's well established in house manufacturing capability in optical components and sensors that further enable cost-effective fabrication. The competitive SWaP and low cost of the microHSI™ sensor is approaching, and in some cases less than the price point of Multi Spectral Imaging (MSI) sensors. Specific designs of the Corning microHSI™ SHARK visNIR turn-key system are presented along with salient performance characteristics. Initial focus market areas include precision agriculture and historic and recent microHSI™ SHARK prototype test results are presented.
Compact autonomous navigation system (CANS)
NASA Astrophysics Data System (ADS)
Hao, Y. C.; Ying, L.; Xiong, K.; Cheng, H. Y.; Qiao, G. D.
2017-11-01
Autonomous navigation of Satellite and constellation has series of benefits, such as to reduce operation cost and ground station workload, to avoid the event of crises of war and natural disaster, to increase spacecraft autonomy, and so on. Autonomous navigation satellite is independent of ground station support. Many systems are developed for autonomous navigation of satellite in the past 20 years. Along them American MANS (Microcosm Autonomous Navigation System) [1] of Microcosm Inc. and ERADS [2] [3] (Earth Reference Attitude Determination System) of Honeywell Inc. are well known. The systems anticipate a series of good features of autonomous navigation and aim low cost, integrated structure, low power consumption and compact layout. The ERADS is an integrated small 3-axis attitude sensor system with low cost and small volume. It has the Earth center measurement accuracy higher than the common IR sensor because the detected ultraviolet radiation zone of the atmosphere has a brightness gradient larger than that of the IR zone. But the ERADS is still a complex system because it has to eliminate many problems such as making of the sapphire sphere lens, birefringence effect of sapphire, high precision image transfer optical fiber flattener, ultraviolet intensifier noise, and so on. The marginal sphere FOV of the sphere lens of the ERADS is used to star imaging that may be bring some disadvantages., i.e. , the image energy and attitude measurements accuracy may be reduced due to the tilt image acceptance end of the fiber flattener in the FOV. Besides Japan, Germany and Russia developed visible earth sensor for GEO [4] [5]. Do we have a way to develop a cheaper/easier and more accurate autonomous navigation system that can be used to all LEO spacecraft, especially, to LEO small and micro satellites? To return this problem we provide a new type of the system—CANS (Compact Autonomous Navigation System) [6].
NASA Astrophysics Data System (ADS)
Lee, Graham C. B.; Van Hoe, Bram; Yan, Zhijun; Maskery, Oliver; Sugden, Kate; Webb, David; Van Steenberge, Geert
2012-03-01
We present a compact, portable and low cost generic interrogation strain sensor system using a fibre Bragg grating configured in transmission mode with a vertical-cavity surface-emitting laser (VCSEL) light source and a GaAs photodetector embedded in a polymer skin. The photocurrent value is read and stored by a microcontroller. In addition, the photocurrent data is sent via Bluetooth to a computer or tablet device that can present the live data in a real time graph. With a matched grating and VCSEL, the system is able to automatically scan and lock the VCSEL to the most sensitive edge of the grating. Commercially available VCSEL and photodetector chips are thinned down to 20 μm and integrated in an ultra-thin flexible optical foil using several thin film deposition steps. A dedicated micro mirror plug is fabricated to couple the driving optoelectronics to the fibre sensors. The resulting optoelectronic package can be embedded in a thin, planar sensing sheet and the host material for this sheet is a flexible and stretchable polymer. The result is a fully embedded fibre sensing system - a photonic skin. Further investigations are currently being carried out to determine the stability and robustness of the embedded optoelectronic components.
Liquid refractive index sensing independent of opacity using an optofluidic diffraction sensor.
Xu, Zhida; Han, Kevin; Khan, Ibrahim; Wang, Xinhao; Liu, G Logan
2014-10-15
We have implemented a multifunctional optofluidic sensor that can monitor changes in the refractive index and pressure of biofluid simultaneously and can detect free-solution molecular interaction in situ. In this Letter, we demonstrate two major improvements of this sensor proven by both simulation and experiments. One improvement is the broader measurement range of refractive index by making the diffraction grating with high-index polymer. The other improvement is the separation of refractive index sensing from opacity sensing by using the relative power ratio of diffraction orders. This simple, compact and low-cost multifunctional optofluidic sensor has the potential to be used for in situ biofluid monitoring.
Sensor fusion to enable next generation low cost Night Vision systems
NASA Astrophysics Data System (ADS)
Schweiger, R.; Franz, S.; Löhlein, O.; Ritter, W.; Källhammer, J.-E.; Franks, J.; Krekels, T.
2010-04-01
The next generation of automotive Night Vision Enhancement systems offers automatic pedestrian recognition with a performance beyond current Night Vision systems at a lower cost. This will allow high market penetration, covering the luxury as well as compact car segments. Improved performance can be achieved by fusing a Far Infrared (FIR) sensor with a Near Infrared (NIR) sensor. However, fusing with today's FIR systems will be too costly to get a high market penetration. The main cost drivers of the FIR system are its resolution and its sensitivity. Sensor cost is largely determined by sensor die size. Fewer and smaller pixels will reduce die size but also resolution and sensitivity. Sensitivity limits are mainly determined by inclement weather performance. Sensitivity requirements should be matched to the possibilities of low cost FIR optics, especially implications of molding of highly complex optical surfaces. As a FIR sensor specified for fusion can have lower resolution as well as lower sensitivity, fusing FIR and NIR can solve performance and cost problems. To allow compensation of FIR-sensor degradation on the pedestrian detection capabilities, a fusion approach called MultiSensorBoosting is presented that produces a classifier holding highly discriminative sub-pixel features from both sensors at once. The algorithm is applied on data with different resolution and on data obtained from cameras with varying optics to incorporate various sensor sensitivities. As it is not feasible to record representative data with all different sensor configurations, transformation routines on existing high resolution data recorded with high sensitivity cameras are investigated in order to determine the effects of lower resolution and lower sensitivity to the overall detection performance. This paper also gives an overview of the first results showing that a reduction of FIR sensor resolution can be compensated using fusion techniques and a reduction of sensitivity can be compensated.
Compact and cost-effective multi-channel optical spectrometer for fine FBG sensing in IoT technology
NASA Astrophysics Data System (ADS)
Konishi, Tsuyoshi; Yamasaki, Yu
2018-02-01
Optical fiber sensor networks have attracted much attention in IoT technology and a fiber Bragg grating is one of key sensor devices there because of their advantages in a high affinity for optical fiber networks, compactness, immunity to electromagnetic interference and so on. Nevertheless, its sensitivity is not always satisfactory so as to be usable together with widespread cost-effective multi-channel spectrometers. In this paper, we introduce a new cost-effective approach for a portable multi-channel spectrometer with high spectral resolution and demonstrates some preliminary experimental results for fine FBG sensing.
Oliveira-Silva, Rui; Silva, Nuno J. O.; André, Paulo S.; Ferreira, Rute A. S.
2018-01-01
The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10−4 RIU) and limit of detection (LOD = 2 × 10−4) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells. PMID:29534514
Yebo, Nebiyu A; Lommens, Petra; Hens, Zeger; Baets, Roel
2010-05-24
Optical structures fabricated on silicon-on-insulator technology provide a convenient platform for the implementation of highly compact, versatile and low cost devices. In this work, we demonstrate the promise of this technology for integrated low power and low cost optical gas sensing. A room temperature ethanol vapor sensor is demonstrated using a ZnO nanoparticle film as a coating on an SOI micro-ring resonator of 5 microm in radius. The local coating on the ring resonators is prepared from colloidal suspensions of ZnO nanoparticles of around 3 nm diameter. The porous nature of the coating provides a large surface area for gas adsorption. The ZnO refractive index change upon vapor adsorption shifts the microring resonance through evanescent field interaction. Ethanol vapor concentrations down to 100 ppm are detected with this sensing configuration and a detection limit below 25 ppm is estimated.
Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei; Tittel, Frank K.; Li, Chunguang
2016-02-25
Two compact TDLAS sensor systems based on different structural optical cores were developed. The two optical cores combine two recent developments, gallium antimonide (GaSb)-based ICL and a compact multipass gas cell (MPGC) with the goal to create compact TDLAS based sensors for the mid-IR gas detection with high detection sensitivity and low power consumption. The sensors achieved minimum detection limits of ~5 ppbv and ~8 ppbv, respectively, for CH 4 and C 2H 6 concentration measurements with a 3.7-W power consumption.
Long, Ruiqi; McShane, Mike
2012-09-01
Implantable luminescent sensors are being developed for on-demand monitoring of blood glucose levels. For these sensors to be deployed in vivo, a matched external hardware system is needed. In this paper, we designed a compact, low-cost optical system with highly efficient photon delivery and collection using advanced optical modeling software. Compared to interrogation with a fiber bundle, the new system was predicted to improve interrogation efficiency by a factor of 200 for native sensors; an improvement of 37 times was predicted for sensors implanted at a depth of 1 mm in a skin-simulating phantom. A physical prototype was tested using silicone-based skin phantoms developed specifically to mimic the scattering and absorbing properties of human skin. The experimental evaluations revealed that the prototype device performed in agreement with expectations from simulation results, resulting in an overall improvement of over 2000 times. This efficient system enables use of a low-cost commercial spectrometer for recording sensor emission, which was not possible using only fiber optic delivery and collection, and will be used as a tool for in vivo studies with animal models or human subjects.
Thermal Weapon Sight (TWS) AN/PAS-13 diffractive optics designed for producibility
NASA Technical Reports Server (NTRS)
Anderson, J. Steven; Chen, Chungte W.; Spande, Robert A.
1993-01-01
The Thermal Weapon Sight (TWS) program is a manportable 3-5 micrometer forward-looking-infrared (FLIR) rifle sight. The manportable nature requires that the optics modules be lightweight, low cost and compact while maximizing performance. These objectives were met with diffractive optics. TWS promises to be the first FLIR sensor to incorporate kinoform surfaces in full scale production.
Sánchez, Antonio; Blanc, Sara; Yuste, Pedro; Perles, Angel; Serrano, Juan José
2012-01-01
This paper is focused on the description of the physical layer of a new acoustic modem called ITACA. The modem architecture includes as a major novelty an ultra-low power asynchronous wake-up system implementation for underwater acoustic transmission that is based on a low-cost off-the-shelf RFID peripheral integrated circuit. This feature enables a reduced power dissipation of 10 μW in stand-by mode and registers very low power values during reception and transmission. The modem also incorporates clear channel assessment (CCA) to support CSMA-based medium access control (MAC) layer protocols. The design is part of a compact platform for a long-life short/medium range underwater wireless sensor network. PMID:22969324
Sánchez, Antonio; Blanc, Sara; Yuste, Pedro; Perles, Angel; Serrano, Juan José
2012-01-01
This paper is focused on the description of the physical layer of a new acoustic modem called ITACA. The modem architecture includes as a major novelty an ultra-low power asynchronous wake-up system implementation for underwater acoustic transmission that is based on a low-cost off-the-shelf RFID peripheral integrated circuit. This feature enables a reduced power dissipation of 10 μW in stand-by mode and registers very low power values during reception and transmission. The modem also incorporates clear channel assessment (CCA) to support CSMA-based medium access control (MAC) layer protocols. The design is part of a compact platform for a long-life short/medium range underwater wireless sensor network.
Ah Lee, Seung; Ou, Xiaoze; Lee, J Eugene; Yang, Changhuei
2013-06-01
We demonstrate a silo-filter (SF) complementary metal-oxide semiconductor (CMOS) image sensor for a chip-scale fluorescence microscope. The extruded pixel design with metal walls between neighboring pixels guides fluorescence emission through the thick absorptive filter to the photodiode of a pixel. Our prototype device achieves 13 μm resolution over a wide field of view (4.8 mm × 4.4 mm). We demonstrate bright-field and fluorescence longitudinal imaging of living cells in a compact, low-cost configuration.
Compact and low-cost fiber optic thermometer
NASA Astrophysics Data System (ADS)
Sun, Mei H.
1997-06-01
Commercial fiberoptic thermometers have been available for a number of years. The early products were unreliable and high in price. However, the continuing effort in the development of new sensing techniques along with the breakthroughs made in many areas of optoelectronics in recent years have made the production of cost competitive and reliable systems feasible. A fluorescence decay time based system has been demonstrated to successfully meet both cost and performance requirements for various medical applications. A very critical element to the success of this low cost and compact fiberoptic thermometer is the fluorescent sensor material. The very high quantum efficiency, the operating wavelengths, and the temperature sensitivity helped significantly in simplifying the design requirements for the optics and the electronics. The one to eight channel unit contains one to eight modules of a simple optical assembly: an LED light source, a small lens, and a filter are housed in an injection molded plastic container. Both the electronics and the optics reside on a small printed circuit board of approximately 6 inches by 3 inches. This system can be packaged as a stand alone unit or embedded in original manufacturer equipment.
A Compact and Low Cost Electronic Nose for Aroma Detection
Macías, Miguel Macías; Agudo, J. Enrique; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo
2013-01-01
This article explains the development of a prototype of a portable and a very low-cost electronic nose based on an mbed microcontroller. Mbeds are a series of ARM microcontroller development boards designed for fast, flexible and rapid prototyping. The electronic nose is comprised of an mbed, an LCD display, two small pumps, two electro-valves and a sensor chamber with four TGS Figaro gas sensors. The performance of the electronic nose has been tested by measuring the ethanol content of wine synthetic matrices and special attention has been paid to the reproducibility and repeatability of the measurements taken on different days. Results show that the electronic nose with a neural network classifier is able to discriminate wine samples with 10, 12 and 14% V/V alcohol content with a classification error of less than 1%. PMID:23698265
The use of colorimetric sensor arrays to discriminate between pathogenic bacteria.
Lonsdale, Claire L; Taba, Brian; Queralto, Nuria; Lukaszewski, Roman A; Martino, Raymond A; Rhodes, Paul A; Lim, Sung H
2013-01-01
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention's list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in solid media culture in an Advisory Committee on Dangerous Pathogen Containment Level 3 laboratory. At inoculum concentrations as low as 8 colony-forming units per plate, 4 different bacterial species were identified with 100% accuracy using logistic regression to classify the kinetic profile of sensor responses to culture headspace gas. The sensor array was able to further discriminate between different strains of the same species, including 5 strains of Yersinia pestis and Bacillus anthracis. These preliminary results suggest that disposable colorimetric sensor arrays can be an effective, low-cost tool to identify pathogenic bacteria.
The Use of Colorimetric Sensor Arrays to Discriminate between Pathogenic Bacteria
Lonsdale, Claire L.; Taba, Brian; Queralto, Nuria; Lukaszewski, Roman A.; Martino, Raymond A.; Rhodes, Paul A.; Lim, Sung H.
2013-01-01
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention’s list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in solid media culture in an Advisory Committee on Dangerous Pathogen Containment Level 3 laboratory. At inoculum concentrations as low as 8 colony-forming units per plate, 4 different bacterial species were identified with 100% accuracy using logistic regression to classify the kinetic profile of sensor responses to culture headspace gas. The sensor array was able to further discriminate between different strains of the same species, including 5 strains of Yersinia pestis and Bacillus anthracis. These preliminary results suggest that disposable colorimetric sensor arrays can be an effective, low-cost tool to identify pathogenic bacteria. PMID:23671629
An Investigation of New Snow Water Equivalence Sensing Modalities
NASA Astrophysics Data System (ADS)
Frolik, J.; Skalka, C.; Wemple, B.
2008-12-01
It is well known that snowpack is highly variable and influenced by a range of factors, including topography and vegetation cover. As such, single point measurements may be viewed as being inadequate to characterize snowpack in a given area. Thus motivated by the desire for distributed sensing, this work presents results of a proof-of-concept investigation for new, low-cost, snow water equivalence (SWE) sensors based on the attenuation of microwave and gamma radiation. First, our work considers the attenuation of microwave signals at 2.4 GHz and 5 GHz due to an accumulating snowpack. These frequencies coincide with those used for common wireless networks and thus our proposed sensor can leverage existing hardware designs which are low-cost and power efficient. Second, we present attenuation data for radiation energy occurring between 500 keV and 1 MeV. These results were obtained utilizing a radiation detector based on Cadmium Zinc Telluride (CZT) technology. The proposed sensor will leverage recent investments such CZT based designs for homeland security applications. We contend that sensors based on these modalities will be low-cost and low-energy and thus readily integrated with wireless sensor network hardware for distributed monitoring. In addition, these sensors will be compact and thus can be placed in locations not feasible for current SWE sensor designs (e.g., snow pillows) or in locations too dangerous for snow course measurements (e.g., areas prone to avalanche). Since neither sensing methods requires contact with the snowpack, these modalities are also immune to snow bridging effects which plague existing designs. We also present preliminary findings of work conducted in a mountainous forested setting in northern New England which examines the influence of forest vegetation on snowpack.
Microtube strip heat exchanger
NASA Astrophysics Data System (ADS)
Doty, F. D.
1992-07-01
The purpose of this contract has been to explore the limits of miniaturization of heat exchangers with the goals of (1) improving the theoretical understanding of laminar heat exchangers, (2) evaluating various manufacturing difficulties, and (3) identifying major applications for the technology. A low-cost, ultra-compact heat exchanger could have an enormous impact on industry in the areas of cryocoolers and energy conversion. Compact cryocoolers based on the reverse Brayton cycle (RBC) would become practical with the availability of compact heat exchangers. Many experts believe that hardware advances in personal computer technology will rapidly slow down in four to six years unless lowcost, portable cryocoolers suitable for the desktop supercomputer can be developed. Compact refrigeration systems would permit dramatic advances in high-performance computer work stations with 'conventional' microprocessors operating at 150 K, and especially with low-cost cryocoolers below 77 K. NASA has also expressed strong interest in our MTS exchanger for space-based RBC cryocoolers for sensor cooling. We have demonstrated feasibility of higher specific conductance by a factor of five than any other work in high-temperature gas-to-gas exchangers. These laminar-flow, microtube exchangers exhibit extremely low pressure drop compared to alternative compact designs under similar conditions because of their much shorter flow length and larger total flow area for lower flow velocities. The design appears to be amenable to mass production techniques, but considerable process development remains. The reduction in materials usage and the improved heat exchanger performance promise to be of enormous significance in advanced engine designs and in cryogenics.
Cellular telephone-based radiation sensor and wide-area detection network
Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA
2006-12-12
A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.
Edaq530: A Transparent, Open-End and Open-Source Measurement Solution in Natural Science Education
ERIC Educational Resources Information Center
Kopasz, Katalin; Makra, Peter; Gingl, Zoltan
2011-01-01
We present Edaq530, a low-cost, compact and easy-to-use digital measurement solution consisting of a thumb-sized USB-to-sensor interface and measurement software. The solution is fully open-source, our aim being to provide a viable alternative to professional solutions. Our main focus in designing Edaq530 has been versatility and transparency. In…
Combating Terrorism: 2005 TSWG Review
2005-01-01
will have a greater capacity and will be more compact than existing kits. Advanced Hybrid Chemical Detection System Existing sensor systems to...detect chemical agents are either very expensive or provide limited sensitivity and response. Avir, LLC designed and built a hybrid detection system for... hybrid system at an equally low cost. The system has undergone live-agent testing and environmental testing. Extended field-testing in select buildings
The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor
NASA Technical Reports Server (NTRS)
Chan, Eugene
2015-01-01
The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.
Environmental monitors in the Midcourse Space Experiments (MSX)
NASA Technical Reports Server (NTRS)
Uy, O. M.
1993-01-01
The Midcourse Space Experiment (MSX) is an SDIO sponsored space based sensor experiment with a full complement of optical sensors. Because of the possible deleterious effect of both molecular and particulate contamination on these sensors, a suite of environmental monitoring instruments are also being flown with the spacecraft. These instruments are the Total Pressure Sensor based on the cold-cathode gauge, a quadrupole mass spectrometer, a Bennett-type ion mass spectrometer, a cryogenic quartz crystal microbalance (QCM), four temperature-controlled QCM's, and a Xenon and Krypton Flash Lamp Experiment. These instruments have been fully space-qualified, are compact and low cost, and are possible candidate sensors for near-term planetary and atmospheric monitoring. The philosophy adopted during design and fabrication, calibration and ground testing, and modeling will be discussed .
Refractive index sensor based on lateral-offset of coreless silica interferometer
NASA Astrophysics Data System (ADS)
Baharin, Nur Faizzah; Azmi, Asrul Izam; Abdullah, Ahmad Sharmi; Mohd Noor, Muhammad Yusof
2018-02-01
A compact, cost-effective and high sensitivity fiber interferometer refractive index (RI) sensor based on symmetrical offset coreless silica fiber (CSF) configuration is proposed, optimized and demonstrated. The sensor is formed by splicing a section of CSF between two CSF sections in an offset manner. Thus, two distinct optical paths are created with large index difference, the first path through the connecting CSF sections and the second path is outside the CSF through the surrounding media. RI sensing is established from direct interaction of light with surrounding media, hence high sensitivity can be achieved with a relatively compact sensor length. In the experimental work, a 1.5 mm sensor demonstrates RI sensitivity of 750 nm/RIU for RI range between 1.33 and 1.345. With the main attributes of high sensitivity and compact size, the proposed sensor can be further developed for related applications including blood diagnosis, water quality control and food industries.
A compact multi-channel fluorescence sensor with ambient light suppression
NASA Astrophysics Data System (ADS)
Egly, Dominik; Geörg, Daniel; Rädle, Matthias; Beuermann, Thomas
2012-03-01
A multi-channel fluorescence sensor has been developed for process monitoring and fluorescence diagnostics. It comprises a fiber-optic set-up with an immersion probe and an intensity-modulated high power ultraviolet light-emitting diode as a light source for fluorescence excitation. By applying an electronic lock-in procedure, fluorescence signals are selectively detectable at ambient light levels of 1000 000 times higher intensity. The sensor was designed to be compact, low cost and easily adaptable to a wide field of application. The set-up was used to simultaneously monitor three important metabolic fluorophores: NAD(P)H, flavins and porphyrins during the cultivation of a baker's yeast. Moreover, the accumulation and degradation kinetics of protoporphyrin IX induced by 5-aminolevulinic acid on the skin could be recorded by the sensor. The detection limit for protoporphyrin IX was determined to be 4 × 10-11 mol L-1. The linear signal amplification of the sensor and time courses of fluorescence signals monitored during yeast fermentations were validated using a commercial CCD spectrometer. The robust and flexible set-up of the fiber-optic measurement system promises easy implementation of this non-invasive analytical tool to fluorescence monitoring and diagnostics in R&D and production.
A simple low cost latent fingerprint sensor based on deflectometry and WFT analysis
NASA Astrophysics Data System (ADS)
Dhanotia, Jitendra; Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi
2018-02-01
In criminal investigations, latent fingerprints are one of the most significant forms of evidence and most commonly used forensic investigation tool worldwide. The existing non-contact latent fingerprint detection systems are bulky, expensive and require environment which is shock and vibration resistant, thereby limiting their usability outside the laboratory. In this article, a compact, full field, low cost technique for profiling of fingerprints using deflectometry is proposed. Using inexpensive mobile phone screen based structured illumination, and windowed Fourier transform (WFT) based phase retrieval mechanism, the 2D and 3D phase plots reconstruct the profile information of the fingerprint. The phase information is also used to confirm a match between two fingerprints in real time. Since the proposed technique is non-interferometric, the measurements are least affected by environmental perturbations. Using the proposed technique, a portable sensor capable of field deployment has been realized.
A new compact and low cost Langmuir Probe and associated onboard data handling system for CubeSat
NASA Astrophysics Data System (ADS)
Muralikrishna, Polinaya; Domingos, Sinval; Paredes, Andres; Abrahão Dos Santos, Walter
2016-07-01
A new compact and low cost Langmuir Probe and associated onboard data handling system are being developed at Instituto Nacional de Pesquisas Espaciais for launching on board one of the future 2U CubeSat missions. The system is a simplified and compacted version of the Langmuir Probe payloads launched on board several Brazilian SONDA III rockets and also developed for the Brazilian scientific satellites SACI-1 and SACI-2. The onboard data handling system will have the dual functions of preprocessing the data collected by the Langmuir Probe and acting as the interface between the experiment and the on board computer. The Langmuir Probe sensor in the form of two rectangular stainless steel strips of total surface area of approximately 80cm2 will be deployed soon after the injection of the CubeSat into orbit. A sweep voltage varying linearly from 0V to 3.0V in about 1.5 seconds and then remaining fixed at 3.0V for 1 second will be applied to the LP sensor to obtain both the electron density and electron temperature. A high sensitivity preamplifier will be used to convert the sensor current expected to be in the range of a few nano amperes to a few micro amperes into a varying potential. In order to cover the large dynamic range of the expected sensor current the preamplifier output will be further amplified by a logarithmic amplifier before being sampled and sent to the data handling system. The data handling system is projected to handle 8 analog channels and 4 digital words of 8 bits each. The incoming data will be stored in a RAM and later sent to the on board computer using a serial RS422 communication protocol. The interface unit will process the telecommands received from the on board computer. The interface is also projected to do FFT analysis of the LP sensor data and send the averaged FFT spectral amplitudes in place of the original unprocessed data. The system details are presented here.
Castell, Nuria; Dauge, Franck R; Schneider, Philipp; Vogt, Matthias; Lerner, Uri; Fishbain, Barak; Broday, David; Bartonova, Alena
2017-02-01
The emergence of low-cost, user-friendly and very compact air pollution platforms enable observations at high spatial resolution in near-real-time and provide new opportunities to simultaneously enhance existing monitoring systems, as well as engage citizens in active environmental monitoring. This provides a whole new set of capabilities in the assessment of human exposure to air pollution. However, the data generated by these platforms are often of questionable quality. We have conducted an exhaustive evaluation of 24 identical units of a commercial low-cost sensor platform against CEN (European Standardization Organization) reference analyzers, evaluating their measurement capability over time and a range of environmental conditions. Our results show that their performance varies spatially and temporally, as it depends on the atmospheric composition and the meteorological conditions. Our results show that the performance varies from unit to unit, which makes it necessary to examine the data quality of each node before its use. In general, guidance is lacking on how to test such sensor nodes and ensure adequate performance prior to marketing these platforms. We have implemented and tested diverse metrics in order to assess if the sensor can be employed for applications that require high accuracy (i.e., to meet the Data Quality Objectives defined in air quality legislation, epidemiological studies) or lower accuracy (i.e., to represent the pollution level on a coarse scale, for purposes such as awareness raising). Data quality is a pertinent concern, especially in citizen science applications, where citizens are collecting and interpreting the data. In general, while low-cost platforms present low accuracy for regulatory or health purposes they can provide relative and aggregated information about the observed air quality. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Broadband image sensor array based on graphene-CMOS integration
NASA Astrophysics Data System (ADS)
Goossens, Stijn; Navickaite, Gabriele; Monasterio, Carles; Gupta, Shuchi; Piqueras, Juan José; Pérez, Raúl; Burwell, Gregory; Nikitskiy, Ivan; Lasanta, Tania; Galán, Teresa; Puma, Eric; Centeno, Alba; Pesquera, Amaia; Zurutuza, Amaia; Konstantatos, Gerasimos; Koppens, Frank
2017-06-01
Integrated circuits based on complementary metal-oxide-semiconductors (CMOS) are at the heart of the technological revolution of the past 40 years, enabling compact and low-cost microelectronic circuits and imaging systems. However, the diversification of this platform into applications other than microcircuits and visible-light cameras has been impeded by the difficulty to combine semiconductors other than silicon with CMOS. Here, we report the monolithic integration of a CMOS integrated circuit with graphene, operating as a high-mobility phototransistor. We demonstrate a high-resolution, broadband image sensor and operate it as a digital camera that is sensitive to ultraviolet, visible and infrared light (300-2,000 nm). The demonstrated graphene-CMOS integration is pivotal for incorporating 2D materials into the next-generation microelectronics, sensor arrays, low-power integrated photonics and CMOS imaging systems covering visible, infrared and terahertz frequencies.
Gil, Yeongjoon; Wu, Wanqing; Lee, Jungtae
2012-01-01
Background Human life can be further improved if diseases and disorders can be predicted before they become dangerous, by correctly recognizing signals from the human body, so in order to make disease detection more precise, various body-signals need to be measured simultaneously in a synchronized manner. Object This research aims at developing an integrated system for measuring four signals (EEG, ECG, respiration, and PPG) and simultaneously producing synchronous signals on a Wireless Body Sensor Network. Design We designed and implemented a platform for multiple bio-signals using Bluetooth communication. Results First, we developed a prototype board and verified the signals from the sensor platform using frequency responses and quantities. Next, we designed and implemented a lightweight, ultra-compact, low cost, low power-consumption Printed Circuit Board. Conclusion A synchronous multi-body sensor platform is expected to be very useful in telemedicine and emergency rescue scenarios. Furthermore, this system is expected to be able to analyze the mutual effects among body signals. PMID:23112605
Compact SAR and Small Satellite Solutions for Earth Observation
NASA Astrophysics Data System (ADS)
LaRosa, M.; L'Abbate, M.
2016-12-01
Requirements for near and short term mission applications (Observation and Reconnaissance, SIGINT, Early Warning, Meteorology,..) are increasingly calling for spacecraft operational responsiveness, flexible configuration, lower cost satellite constellations and flying formations, to improve both the temporal performance of observation systems (revisit, response time) and the remote sensing techniques (distributed sensors, arrays, cooperative sensors). In answer to these users' needs, leading actors in Space Systems for EO are involved in development of Small and Microsatellites solutions. Thales Alenia Space (TAS) has started the "COMPACT-SAR" project to develop a SAR satellite characterized by low cost and reduced mass while providing, at the same time, high image quality in terms of resolution, swath size, and radiometric performance. Compact SAR will embark a X-band SAR based on a deployable reflector antenna fed by an active phased array feed. This concept allows high performance, providing capability of electronic beam steering both in azimuth and elevation planes, improving operational performance over a purely mechanically steered SAR system. Instrument provides both STRIPMAP and SPOTLIGHT modes, and thanks to very high gain antenna, can also provide a real maritime surveillance mode based on a patented Low PRF radar mode. Further developments are in progress considering missions based on Microsatellites technology, which can provide effective solutions for different user needs, such as Operational responsiveness, low cost constellations, distributed observation concept, flying formations, and can be conceived for applications in the field of Observation, Atmosphere sensing, Intelligence, Surveillance, Reconnaissance (ISR), Signal Intelligence. To satisfy these requirements, flexibility of small platforms is a key driver and especially new miniaturization technologies able to optimize the performance. An overview new micros-satellite (based on NIMBUS platform) and mission concepts is provided, such as passive SAR for multi-static imaging and tandem, Medium swath/medium resolution dual pol MICROSAR for in L-C-X band multi-application for maritime surveillance and land monitoring, applications for Space Debris monitoring, precision farming, Atmosphere sensing.
NASA Astrophysics Data System (ADS)
Linares, Rodrigo; Vergara, German; Gutiérrez, Raúl; Fernández, Carlos; Villamayor, Víctor; Gómez, Luis; González-Camino, Maria; Baldasano, Arturo; Castro, G.; Arias, R.; Lapido, Y.; Rodríguez, J.; Romero, Pablo
2015-05-01
The combination of flexibility, productivity, precision and zero-defect manufacturing in future laser-based equipment are a major challenge that faces this enabling technology. New sensors for online monitoring and real-time control of laserbased processes are necessary for improving products quality and increasing manufacture yields. New approaches to fully automate processes towards zero-defect manufacturing demand smarter heads where lasers, optics, actuators, sensors and electronics will be integrated in a unique compact and affordable device. Many defects arising in laser-based manufacturing processes come from instabilities in the dynamics of the laser process. Temperature and heat dynamics are key parameters to be monitored. Low cost infrared imagers with high-speed of response will constitute the next generation of sensors to be implemented in future monitoring and control systems for laser-based processes, capable to provide simultaneous information about heat dynamics and spatial distribution. This work describes the result of using an innovative low-cost high-speed infrared imager based on the first quantum infrared imager monolithically integrated with Si-CMOS ROIC of the market. The sensor is able to provide low resolution images at frame rates up to 10 KHz in uncooled operation at the same cost as traditional infrared spot detectors. In order to demonstrate the capabilities of the new sensor technology, a low-cost camera was assembled on a standard production laser welding head, allowing to register melting pool images at frame rates of 10 kHz. In addition, a specific software was developed for defect detection and classification. Multiple laser welding processes were recorded with the aim to study the performance of the system and its application to the real-time monitoring of laser welding processes. During the experiments, different types of defects were produced and monitored. The classifier was fed with the experimental images obtained. Self-learning strategies were implemented with very promising results, demonstrating the feasibility of using low-cost high-speed infrared imagers in advancing towards a real-time / in-line zero-defect production systems.
Wireless structural monitoring for homeland security applications
NASA Astrophysics Data System (ADS)
Kiremidjian, Garo K.; Kiremidjian, Anne S.; Lynch, Jerome P.
2004-07-01
This paper addresses the development of a robust, low-cost, low power, and high performance autonomous wireless monitoring system for civil assets such as large facilities, new construction, bridges, dams, commercial buildings, etc. The role of the system is to identify the onset, development, location and severity of structural vulnerability and damage. The proposed system represents an enabling infrastructure for addressing structural vulnerabilities specifically associated with homeland security. The system concept is based on dense networks of "intelligent" wireless sensing units. The fundamental properties of a wireless sensing unit include: (a) interfaces to multiple sensors for measuring structural and environmental data (such as acceleration, displacements, pressure, strain, material degradation, temperature, gas agents, biological agents, humidity, corrosion, etc.); (b) processing of sensor data with embedded algorithms for assessing damage and environmental conditions; (c) peer-to-peer wireless communications for information exchange among units(thus enabling joint "intelligent" processing coordination) and storage of data and processed information in servers for information fusion; (d) ultra low power operation; (e) cost-effectiveness and compact size through the use of low-cost small-size off-the-shelf components. An integral component of the overall system concept is a decision support environment for interpretation and dissemination of information to various decision makers.
Open hardware, low cost, air quality stations for monitoring ozone in coastal area
NASA Astrophysics Data System (ADS)
Lima, Marco; Donzella, Davide; Pintus, Fabio; Fedi, Adriano; Ferrari, Daniele; Massabò, Marco
2014-05-01
Ozone concentrations in urban and coastal area are a great concern for citizens and, consequently regulator. In the last 20 years the Ozone concentration is almost doubled and it has attracted the public attention because of the well know harmful impacts on human health and biosphere in general. Official monitoring networks usually comprise high precision, high accuracy observation stations, usually managed by public administrations and environmental agency; unfortunately due to their high costs of installation and maintenance, the monitoring stations are relatively sparse. This kind of monitoring networks have been recognized to be unsuitable to effectively characterize the high variability of air quality, especially in areas where pollution sources are various and often not static. We present a prototype of a low cost station for air quality monitoring, specifically developed for complementing the official monitoring stations improving the representation of air quality spatial distribution. We focused on a semi-professional product that could guarantee the highest reliability at the lowest possible cost, supported by a consistent infrastructure for data management. We test two type of Ozone sensor electrochemical and metal oxide. This work is integrated in the ACRONET Paradigm ® project: an open-hardware platform strongly oriented on environmental monitoring. All software and hardware sources will be available on the web. Thus, a computer and a small amount of work tools will be sufficient to create new monitoring networks, with the only constraint to share all the data obtained. It will so possible to create a real "sensing community". The prototype is currently able to measure ozone level, temperature and relative humidity, but soon, with the upcoming changes, it will be able also to monitor dust, carbon monoxide and nitrogen dioxide, always through the use of commercial sensors. The sensors are grouped in a compact board that interfaces with a data-logger able to transmit data to a dedicated server through a GPRS module (no ad hoc radio infrastructure needed). Due to the GPRS low latency transmission the data are transmitted in near-real time. The prototype has an independent power supply. The sensors outputs are directly compared with the measurement of the official fixed monitoring stations. We present preliminary tests of a ozone level assessment obtained without laboratory calibration during a first field campaign in Savona (Italy); the preliminary verification and test show reasonable agreement between low cost sensors and fixed monitoring station ozone level trends (low cost sensors detect gas concentration at ppb level). The preliminary results are promising for complementing the fixed official monitoring networks with low-cost sensors.
NASA Astrophysics Data System (ADS)
Cheng, Junna; Zhou, Ciming; Fan, Dian; Ou, Yiwen
2017-04-01
We propose and demonstrate a miniature Fabry-Perot (F-P) interferometric sensor based on a hollow glass microsphere (HGM) for highly sensitive temperature measurement. The sensor head is fabricated by sticking a HGM on the end face of a single-mode fiber, and it consists of a short air F-P cavity between the front and the rear surfaces of the HGM. A sensor with 135.7280-μm cavity length was tested for temperature measurement from -5 °C to 50 °C. The obtained sensitivity reached up to 24.5 pm/°C and the variation rate of the HGM- F-P's cavity length was2.1 nm/°C. The advantages of compact size, easy fabrication and low cost make the sensor suitable for highly sensitive temperature sensing.
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media.
Ghaffari, Seyed Alireza; Caron, William-O; Loubier, Mathilde; Normandeau, Charles-O; Viens, Jeff; Lamhamedi, Mohammed S; Gosselin, Benoit; Messaddeq, Younes
2015-07-21
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3- in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications.
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media
Ghaffari, Seyed Alireza; Caron, William-O.; Loubier, Mathilde; Normandeau, Charles-O.; Viens, Jeff; Lamhamedi, Mohammed S.; Gosselin, Benoit; Messaddeq, Younes
2015-01-01
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3− in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications. PMID:26197322
Low-cost rapid miniature optical pressure sensors for blast wave measurements.
Wu, Nan; Wang, Wenhui; Tian, Ye; Zou, Xiaotian; Maffeo, Michael; Niezrecki, Christopher; Chen, Julie; Wang, Xingwei
2011-05-23
This paper presents an optical pressure sensor based on a Fabry-Perot (FP) interferometer formed by a 45° angle polished single mode fiber and an external silicon nitride diaphragm. The sensor is comprised of two V-shape grooves with different widths on a silicon chip, a silicon nitride diaphragm released on the surface of the wider V-groove, and a 45° angle polished single mode fiber. The sensor is especially suitable for blast wave measurements: its compact structure ensures a high spatial resolution; its thin diaphragm based design and the optical demodulation scheme allow a fast response to the rapid changing signals experienced during blast events. The sensor shows linearity with the correlation coefficient of 0.9999 as well as a hysteresis of less than 0.3%. The shock tube test demonstrated that the sensor has a rise time of less than 2 µs from 0 kPa to 140 kPa.
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils.
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-03-14
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring.
Photonic Low Cost Micro-Sensor for in-Line Wear Particle Detection in Flowing Lube Oils
Mabe, Jon; Zubia, Joseba; Gorritxategi, Eneko
2017-01-01
The presence of microscopic particles in suspension in industrial fluids is often an early warning of latent or imminent failures in the equipment or processes where they are being used. This manuscript describes work undertaken to integrate different photonic principles with a micro- mechanical fluidic structure and an embedded processor to develop a fully autonomous wear debris sensor for in-line monitoring of industrial fluids. Lens-less microscopy, stroboscopic illumination, a CMOS imager and embedded machine vision technologies have been merged to develop a sensor solution that is able to detect and quantify the number and size of micrometric particles suspended in a continuous flow of a fluid. A laboratory test-bench has been arranged for setting up the configuration of the optical components targeting a static oil sample and then a sensor prototype has been developed for migrating the measurement principles to real conditions in terms of operating pressure and flow rate of the oil. Imaging performance is quantified using micro calibrated samples, as well as by measuring real used lubricated oils. Sampling a large fluid volume with a decent 2D spatial resolution, this photonic micro sensor offers a powerful tool at very low cost and compacted size for in-line wear debris monitoring. PMID:28335436
An Application of UAV Attitude Estimation Using a Low-Cost Inertial Navigation System
NASA Technical Reports Server (NTRS)
Eure, Kenneth W.; Quach, Cuong Chi; Vazquez, Sixto L.; Hogge, Edward F.; Hill, Boyd L.
2013-01-01
Unmanned Aerial Vehicles (UAV) are playing an increasing role in aviation. Various methods exist for the computation of UAV attitude based on low cost microelectromechanical systems (MEMS) and Global Positioning System (GPS) receivers. There has been a recent increase in UAV autonomy as sensors are becoming more compact and onboard processing power has increased significantly. Correct UAV attitude estimation will play a critical role in navigation and separation assurance as UAVs share airspace with civil air traffic. This paper describes attitude estimation derived by post-processing data from a small low cost Inertial Navigation System (INS) recorded during the flight of a subscale commercial off the shelf (COTS) UAV. Two discrete time attitude estimation schemes are presented here in detail. The first is an adaptation of the Kalman Filter to accommodate nonlinear systems, the Extended Kalman Filter (EKF). The EKF returns quaternion estimates of the UAV attitude based on MEMS gyro, magnetometer, accelerometer, and pitot tube inputs. The second scheme is the complementary filter which is a simpler algorithm that splits the sensor frequency spectrum based on noise characteristics. The necessity to correct both filters for gravity measurement errors during turning maneuvers is demonstrated. It is shown that the proposed algorithms may be used to estimate UAV attitude. The effects of vibration on sensor measurements are discussed. Heuristic tuning comments pertaining to sensor filtering and gain selection to achieve acceptable performance during flight are given. Comparisons of attitude estimation performance are made between the EKF and the complementary filter.
NASA Astrophysics Data System (ADS)
Dutta, D.; Drewry, D.; Johnson, W. R.
2017-12-01
The surface temperature of plant canopies is an important indicator of the stomatal regulation of plant water use and the associated water flux from plants to atmosphere (evapotranspiration (ET)). Remotely sensed thermal observations using compact, low-cost, lightweight sensors from small unmanned aerial systems (sUAS) have the potential to provide surface temperature (ST) and ET estimates at unprecedented spatial and temporal resolutions, allowing us to characterize the intra-field diurnal variations in canopy ST and ET for a variety of vegetation systems. However, major challenges exist for obtaining accurate surface temperature estimates from low-cost uncooled microbolometer-type sensors. Here we describe the development of calibration methods using thermal chamber experiments, taking into account the ambient optics and sensor temperatures, and applying simple models of spatial non-uniformity correction to the sensor focal-plane-array. We present a framework that can be used to derive accurate surface temperatures using radiometric observations from low-cost sensors, and demonstrate this framework using a sUAS-mounted sensor across a diverse set of calibration and vegetation targets. Further, we demonstrate the use of the Surface Temperature Initiated Closure (STIC) model for computing spatially explicit, high spatial resolution ET estimates across several well-monitored agricultural systems, as driven by sUAS acquired surface temperatures. STIC provides a physically-based surface energy balance framework for the simultaneous retrieval of the surface and atmospheric vapor conductances and surface energy fluxes, by physically integrating radiometric surface temperature information into the Penman-Monteith equation. Results of our analysis over agricultural systems in Ames, IA and Davis, CA demonstrate the power of this approach for quantifying the intra-field spatial variability in the diurnal cycle of plant water use at sub-meter resolutions.
Low Power Wireless Smoke Alarm System in Home Fires
Luis, Juan Aponte; Galán, Juan Antonio Gómez; Espigado, Javier Alcina
2015-01-01
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects. PMID:26307994
Low Power Wireless Smoke Alarm System in Home Fires.
Aponte Luis, Juan; Gómez Galán, Juan Antonio; Alcina Espigado, Javier
2015-08-21
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.
Etching twin core fiber for the temperature-independent refractive index sensing
NASA Astrophysics Data System (ADS)
Zhang, Chuanbiao; Ning, Tigang; Li, Jing; Zheng, Jingjing; Gao, Xuekai; Lin, Heng; Pei, Li
2018-04-01
We proposed an ultra-compact chemically etched twin core fiber (TCF) based optic refractive index (RI) sensor, in which the etched fiber was fabricated by immersing in an aqueous solution of hydrofluoric acid (HF) to etch the cladding. Due to the multipath evolutions of light during the TCF, the mode induced interference pattern can be used for measurement. Numerical simulations were performed, demonstrating that only the cladding mode strongly interacts with the surrounding media, and the higher cladding modes will be more sensitive to external medium. In the experiment demonstration, the RI response characteristics of the sensor were investigated, which shows a relatively high RI sensitivity and a much low temperature cross-sensitivity with about 1.06 × 10-6 RIU °C-1. Due to low cost and easy fabrication, the sensor can be a suitable candidate in the biochemical field.
A dual modality optical fiber sensor
NASA Astrophysics Data System (ADS)
Herrera-Piad, Luis A.; Haus, Joseph W.; Jauregui-Vazquez, Daniel; Lopez-Dieguez, Yanelis; Estudillo-Ayala, Julian M.; Sierra-Hernandez, Juan M.; Hernandez-Garcia, Juan C.; Rojas-Laguna, Roberto
2018-02-01
We propose and demonstrate a fibre optic system based on bi-tapered silica fibre that can simultaneously measure strain and fibre curvature. Both modalities on the signal can be extracted with no measurable crosstalk between them. The experimental signal has a pure phase modulation when strain is applied to the tapered fibre optic section of the sensor and the signal shows only intensity modulation when an un-tapered fibre section is bent. High sensitivity is achieved from the experimental results for strain and bending losses and the estimation of measurement errors is 0.2 and 0.1%, respectively. This system offers low-cost, compactness and it can be adapted for structural health monitoring.
GEOScan: A GEOScience Facility From Space
NASA Astrophysics Data System (ADS)
Dyrud, L. P.; Fentzke, J. T.; Anderson, B. J.; Bishop, R. L.; Bust, G. S.; Cahoy, K.; Erlandson, R. E.; Fish, C. S.; Gunter, B. C.; Hall, F. G.; Hilker, T.; Lorentz, S. R.; Mazur, J. E.; Murphy, S. D.; Mustard, J. F.; O'Brien, P. P.; Slagowski, S.; Trenberth, K. E.; Wiscombe, W. J.
2012-12-01
GEOScan is a proposed globally networked orbiting facility that will provide revolutionary, massively dense global geosciences observations. Major scientific research projects are typically conducted using two approaches: community facilities, or investigator led focused missions. GEOScan is a new concept in space science, blending the PI mission and community facility models: it is PI-led, but it carries sensors that are the result of a grass-roots competition, and, uniquely, it preserves open slots for sensors which are purposely not yet decided. The goal is threefold: first, to select sensors that maximize science value for the greatest number of scientific disciplines, second, to target science questions that cannot be answered without simultaneous global space-based measurements, and third to reap the cost advantages of scale manufacturing for space instrumentation. The relatively small size, mass, and power requirements of the GEOScan sensor suite would make it an ideal hosted payload aboard a global constellation of communication satellites, such as Iridium NEXT's 66-satellite constellation or as hosted small-sat payload. Each GEOScan sensor suite consists of 6 instruments: a Radiometer to measure Earth's total outgoing radiation; a GPS Compact Total Electron Content Sensor to image Earth's plasma environment and gravity field; a MicroCam Multispectral Imager to provide the first uniform, instantaneous image of Earth and measure global cloud cover, vegetation, land use, and bright aurora; a Radiation Belt Mapping System (dosimeter) to measure energetic electron and proton distributions; a Compact Earth Observing Spectrometer to measure aerosol-atmospheric composition and vegetation; and MEMS Accelerometers to deduce non-conservative forces aiding gravity and neutral drag studies. These instruments, employed in a constellation, can provide major breakthroughs in Earth and Geospace science, as well as offering a low-cost technology demonstration for operational weather, climate, and land-imaging.
Strategic options towards an affordable high-performance infrared camera
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Dutta, Achyut K.; Lewis, Jay; Dhar, Nibir K.
2016-05-01
The promise of infrared (IR) imaging attaining low-cost akin to CMOS sensors success has been hampered by the inability to achieve cost advantages that are necessary for crossover from military and industrial applications into the consumer and mass-scale commercial realm despite well documented advantages. Banpil Photonics is developing affordable IR cameras by adopting new strategies to speed-up the decline of the IR camera cost curve. We present a new short-wave IR (SWIR) camera; 640x512 pixel InGaAs uncooled system that is high sensitivity low noise (<50e-), high dynamic range (100 dB), high-frame rates (> 500 frames per second (FPS)) at full resolution, and low power consumption (< 1 W) in a compact system. This camera paves the way towards mass market adoption by not only demonstrating high-performance IR imaging capability value add demanded by military and industrial application, but also illuminates a path towards justifiable price points essential for consumer facing application industries such as automotive, medical, and security imaging adoption. Among the strategic options presented include new sensor manufacturing technologies that scale favorably towards automation, multi-focal plane array compatible readout electronics, and dense or ultra-small pixel pitch devices.
NASA Astrophysics Data System (ADS)
Wierzbicki, Damian; Fryskowska, Anna; Kedzierski, Michal; Wojtkowska, Michalina; Delis, Paulina
2018-01-01
Unmanned aerial vehicles are suited to various photogrammetry and remote sensing missions. Such platforms are equipped with various optoelectronic sensors imaging in the visible and infrared spectral ranges and also thermal sensors. Nowadays, near-infrared (NIR) images acquired from low altitudes are often used for producing orthophoto maps for precision agriculture among other things. One major problem results from the application of low-cost custom and compact NIR cameras with wide-angle lenses introducing vignetting. In numerous cases, such cameras acquire low radiometric quality images depending on the lighting conditions. The paper presents a method of radiometric quality assessment of low-altitude NIR imagery data from a custom sensor. The method utilizes statistical analysis of NIR images. The data used for the analyses were acquired from various altitudes in various weather and lighting conditions. An objective NIR imagery quality index was determined as a result of the research. The results obtained using this index enabled the classification of images into three categories: good, medium, and low radiometric quality. The classification makes it possible to determine the a priori error of the acquired images and assess whether a rerun of the photogrammetric flight is necessary.
NASA Astrophysics Data System (ADS)
Lv, Ri-qing; Qian, Jun-kai; Zhao, Yong
2018-03-01
A simple, compact optical fiber magnetic field sensor is proposed and experimentally demonstrated in this paper. It is based on the magnetic-fluid-clad combined with singlemode-multimode-singlemode fiber structure and large core-offset splicing structure. It was protected by a section of capillary tube and was sealed by UV glue. A sensing property study of the combined optical fiber structure and the proposed sensor were carried out. The experimental results show that the sensitivity of the refractive index of the optical fiber sensing structure is up to 156.63 nm/RIU and the magnetic field sensitivity of the proposed sensor is up to -97.24 pm/Oe in the range from 72.4 Oe to 297.8 Oe. The proposed sensor has several other advantages, such as simple structure, small size, easy fabrication and low cost.
Noise Source Visualization Using a Digital Voice Recorder and Low-Cost Sensors
Cho, Yong Thung
2018-01-01
Accurate sound visualization of noise sources is required for optimal noise control. Typically, noise measurement systems require microphones, an analog-digital converter, cables, a data acquisition system, etc., which may not be affordable for potential users. Also, many such systems are not highly portable and may not be convenient for travel. Handheld personal electronic devices such as smartphones and digital voice recorders with relatively lower costs and higher performance have become widely available recently. Even though such devices are highly portable, directly implementing them for noise measurement may lead to erroneous results since such equipment was originally designed for voice recording. In this study, external microphones were connected to a digital voice recorder to conduct measurements and the input received was processed for noise visualization. In this way, a low cost, compact sound visualization system was designed and introduced to visualize two actual noise sources for verification with different characteristics: an enclosed loud speaker and a small air compressor. Reasonable accuracy of noise visualization for these two sources was shown over a relatively wide frequency range. This very affordable and compact sound visualization system can be used for many actual noise visualization applications in addition to educational purposes. PMID:29614038
Cellular telephone-based radiation detection instrument
Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA
2011-06-14
A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.
Cellular telephone-based wide-area radiation detection network
Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA
2009-06-09
A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.
NASA Astrophysics Data System (ADS)
Saruwatari, Shunsuke; Suzuki, Makoto; Morikawa, Hiroyuki
The paper shows a compact hard real-time operating system for wireless sensor nodes called PAVENET OS. PAVENET OS provides hybrid multithreading: preemptive multithreading and cooperative multithreading. Both of the multithreading are optimized for two kinds of tasks on wireless sensor networks, and those are real-time tasks and best-effort ones. PAVENET OS can efficiently perform hard real-time tasks that cannot be performed by TinyOS. The paper demonstrates the hybrid multithreading realizes compactness and low overheads, which are comparable to those of TinyOS, through quantitative evaluation. The evaluation results show PAVENET OS performs 100 Hz sensor sampling with 0.01% jitter while performing wireless communication tasks, whereas optimized TinyOS has 0.62% jitter. In addition, PAVENET OS has a small footprint and low overheads (minimum RAM size: 29 bytes, minimum ROM size: 490 bytes, minimum task switch time: 23 cycles).
Performance analysis of a compact and low-cost mapping-grade mobile laser scanning system
NASA Astrophysics Data System (ADS)
Julge, Kalev; Vajakas, Toivo; Ellmann, Artu
2017-10-01
The performance of a low-cost, self-contained, compact, and easy to deploy mapping-grade mobile laser scanning (MLS) system, which is composed of a light detection and ranging sensor Velodyne VLP-16 and a dual antenna global navigation satellite system/inertial navigation system SBG Systems Ellipse-D, is analyzed. The field tests were carried out in car-mounted and backpack modes for surveying road engineering structures (such as roads, parking lots, underpasses, and tunnels) and coastal erosion zones, respectively. The impact of applied calculation principles on trajectory postprocessing, direct georeferencing, and the theoretical accuracy of the system is analyzed. A calibration method, based on Bound Optimization BY Quadratic Approximation, for finding the boresight angles of an MLS system is proposed. The resulting MLS point clouds are compared with high-accuracy static terrestrial laser scanning data and survey-grade MLS data from a commercially manufactured MLS system. The vertical, horizontal, and relative accuracy are assessed-the root-mean-square error (RMSE) values were determined to be 8, 15, and 3 cm, respectively. Thus, the achieved mapping-grade accuracy demonstrates that this relatively compact and inexpensive self-assembled MLS can be successfully used for surveying the geometry and deformations of terrain, buildings, road, and other engineering structures.
Optical fiber curvature sensor based on MMF-SCF-MMF structure
NASA Astrophysics Data System (ADS)
Wang, Qi; Liu, Yu
2018-07-01
A sensitive curvature sensor based on MMF-SCF-MMF (MMF: multimode fiber; SCF: seven core fiber) structure is proposed. The multimode fiber (MMF) are used to improve the light coupling efficiency between the input singlemode fiber (SMF) and the seven-core fiber (SCF), and the seven-core fiber is used as the main element for curvature measurement. Experimental results show that the best curvature sensitivity reaches 41.46453 nm/m-1 in the range of 0.094 m-1-0.567 m-1. The temperature sensitivity is up to 59.02 pm/°C in the range of 20 °C-55 °C. The optical curvature sensors are widely used for buildings structure health monitoring and mechanical engineering due to the advantages of compact structure, anti-electromagnetic interference, and low cost.
Compact LWIR sensors using spatial interferometric technology (Conference Presentation)
NASA Astrophysics Data System (ADS)
Bingham, Adam L.; Lucey, Paul G.; Knobbe, Edward T.
2017-05-01
Recent developments in reducing the cost and mass of hyperspectral sensors have enabled more widespread use for short range compositional imaging applications. HSI in the long wave infrared (LWIR) is of interest because it is sensitive to spectral phenomena not accessible to other wavelengths, and because of its inherent thermal imaging capability. At Spectrum Photonics we have pursued compact LWIR hyperspectral sensors both using microbolometer arrays and compact cryogenic detector cameras. Our microbolometer-based systems are principally aimed at short standoff applications, currently weigh 10-15 lbs and feature sizes approximately 20x20x10 cm, with sensitivity in the 1-2 microflick range, and imaging times on the order of 30 seconds. Our systems that employ cryogenic arrays are aimed at medium standoff ranges such as nadir looking missions from UAVs. Recent work with cooled sensors has focused on Strained Layer Superlattice (SLS) technology, as these detector arrays are undergoing rapid improvements, and have some advantages compared to HgCdTe detectors in terms of calibration stability. These sensors include full on-board processing sensor stabilization so are somewhat larger than the microbolometer systems, but could be adapted to much more compact form factors. We will review our recent progress in both these application areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thurmond, Kyle; Loparo, Zachary; Partridge, Jr., William P.
Here, a sensor was developed for simultaneous measurements of carbon monoxide (CO) and carbon dioxide (CO 2) fluctuations in internal combustion engine exhaust gases. This sensor utilizes low-cost and compact light-emitting diodes (LEDs) that emit in the 3–5 µm wavelength range. An affordable, fast response sensor that can measure these gases has a broad application that can lead to more efficient, fuel-flexible engines and regulation of harmful emissions. Light emission from LEDs is spectrally broader and more spatially divergent when compared to that of lasers, which presented many design challenges. Optical design studies addressed some of the non-ideal characteristics ofmore » the LED emissions. Measurements of CO and CO 2 were conducted using their fundamental absorption bands centered at 4.7 µm and 4.3 µm, respectively, while a 3.6 µm reference LED was used to account for scattering losses (due to soot, window deposits, etc.) common to the three measurement LEDs. Instrument validation and calibration was performed using a laboratory flow cell and bottled-gas mixtures. The sensor was able to detect CO 2 and CO concentration changes as small as 30 ppm and 400 ppm, respectively. Because of the many control and monitor species with infra-red absorption features, which can be measured using the strategy described, this work demonstrates proof of concept for a wider range of fast (250 Hz) and low-cost sensors for gas measurement and process monitoring.« less
Microstrip Patch Sensor for Salinity Determination.
Lee, Kibae; Hassan, Arshad; Lee, Chong Hyun; Bae, Jinho
2017-12-18
In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS), and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under -20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of -35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF) tunable sensors for salinity determination.
NASA Technical Reports Server (NTRS)
2008-01-01
Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.
Biosensors and bioelectronics on smartphone for portable biochemical detection.
Zhang, Diming; Liu, Qingjun
2016-01-15
Smartphone has been widely integrated with sensors, such as test strips, sensor chips, and hand-held detectors, for biochemical detections due to its portability and ubiquitous availability. Utilizing built-in function modules, smartphone is often employed as controller, analyzer, and displayer for rapid, real-time, and point-of-care monitoring, which can significantly simplify design and reduce cost of the detecting systems. This paper presents a review of biosensors and bioelectronics on smartphone for portable biochemical detections. The biosensors and bioelectronics based on smartphone can mainly be classified into biosensors using optics, surface plasmon resonance, electrochemistry, and near-field communication. The developments of these biosensors and bioelectronics on smartphone are reviewed along with typical biochemical detecting cases. Sensor strategies, detector attachments, and coupling methods are highlighted to show designs of the compact, lightweight, and low-cost sensor systems. The performances and advantages of these designs are introduced with their applications in healthcare diagnosis, environment monitoring, and food evaluation. With advances in micro-manufacture, sensor technology, and miniaturized electronics, biosensor and bioelectronic devices on smartphone can be used to perform biochemical detections as common and convenient as electronic tag readout in foreseeable future. Copyright © 2015 Elsevier B.V. All rights reserved.
Micro-differential scanning calorimeter for liquid biological samples
Wang, Shuyu; Yu, Shifeng; Siedler, Michael S.; ...
2016-10-20
Here, we developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. Our design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. Furthermore, we demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturizedmore » sample consumption.« less
Thurmond, Kyle; Loparo, Zachary; Partridge, Jr., William P.; ...
2016-04-18
Here, a sensor was developed for simultaneous measurements of carbon monoxide (CO) and carbon dioxide (CO 2) fluctuations in internal combustion engine exhaust gases. This sensor utilizes low-cost and compact light-emitting diodes (LEDs) that emit in the 3–5 µm wavelength range. An affordable, fast response sensor that can measure these gases has a broad application that can lead to more efficient, fuel-flexible engines and regulation of harmful emissions. Light emission from LEDs is spectrally broader and more spatially divergent when compared to that of lasers, which presented many design challenges. Optical design studies addressed some of the non-ideal characteristics ofmore » the LED emissions. Measurements of CO and CO 2 were conducted using their fundamental absorption bands centered at 4.7 µm and 4.3 µm, respectively, while a 3.6 µm reference LED was used to account for scattering losses (due to soot, window deposits, etc.) common to the three measurement LEDs. Instrument validation and calibration was performed using a laboratory flow cell and bottled-gas mixtures. The sensor was able to detect CO 2 and CO concentration changes as small as 30 ppm and 400 ppm, respectively. Because of the many control and monitor species with infra-red absorption features, which can be measured using the strategy described, this work demonstrates proof of concept for a wider range of fast (250 Hz) and low-cost sensors for gas measurement and process monitoring.« less
Tritium power source for long-lived sensors
NASA Astrophysics Data System (ADS)
Litz, M. S.; Katsis, D. C.; Russo, J. A.; Carroll, J. J.
2014-06-01
A tritium-based indirect converting photovoltaic (PV) power source has been designed and prototyped as a long-lived (~15 years) power source for sensor networks. Tritium is a biologically benign beta emitter and low-cost isotope acquired from commercial vendors for this purpose. The power source combines tritium encapsulated with a radioluminescent phosphor coupled to a commercial PV cell. The tritium, phosphor, and PV components are packaged inside a BA5590-style military-model enclosure. The package has been approved by the nuclear regulatory commission (NRC) for use by DOD. The power source is designed to produce 100μW electrical power for an unattended radiation sensor (scintillator and avalanche photodiode) that can detect a 20 μCi source of 137Cs at three meters. This beta emitting indirect photon conversion design is presented as step towards the development of practical, logistically acceptable, lowcost long-lived compact power sources for unattended sensor applications in battlefield awareness and environmental detection.
An Instantaneous Low-Cost Point-of-Care Anemia Detection Device
Punter-Villagrasa, Jaime; Cid, Joan; Páez-Avilés, Cristina; Rodríguez-Villarreal, Ivón; Juanola-Feliu, Esteve; Colomer-Farrarons, Jordi; Miribel-Català, Pere Ll.
2015-01-01
We present a small, compact and portable device for point-of-care instantaneous early detection of anemia. The method used is based on direct hematocrit measurement from whole blood samples by means of impedance analysis. This device consists of a custom electronic instrumentation and a plug-and-play disposable sensor. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low consumption device making it completely mobile with a long battery life. Another approach could be powering the system based on other solutions like indoor solar cells, or applying energy-harvesting solutions in order to remove the batteries. The sensing system is based on a disposable low-cost label-free three gold electrode commercial sensor for 50 μL blood samples. The device capability for anemia detection has been validated through 24 blood samples, obtained from four hospitalized patients at Hospital Clínic. As a result, the response, effectiveness and robustness of the portable point-of-care device to detect anemia has been proved with an accuracy error of 2.83% and a mean coefficient of variation of 2.57% without any particular case above 5%. PMID:25690552
NASA Astrophysics Data System (ADS)
Yamashita, Y.; Shinohara, M.; Yamada, T.; Shiobara, H.
2017-12-01
It is important to understand coupling between plates in a subduction zone for studies of earthquake generation. Recently low frequency tremor and very low frequency earthquake (VLFE) were discovered in plate boundary near a trench. These events (slow earthquakes) in shallow plate boundary should be related to slow slip on a plate boundary. For observation of slow earthquakes, Broad Band Ocean Bottom Seismometer (BBOBS) is useful, however a number of BBOBSs are limited due to cost. On the other hand, a number of Long-term OBSs (LT-OBSs) with recording period of one year are available. However, the LT-OBS has seismometer with a natural period of 1 second. Therefore frequency band of observation is slightly narrow for slow earthquakes. Therefore we developed a compact long-term broad-band OBS by replacement of the seismic sensor of the LT-OBSs to broadband seismometer.We adopted seismic sensor with natural period of 20 seconds (Trillium Compact Broadband Seismometer, Nanometrics). Because tilt of OBS on seafloor can not be controlled due to free-fall, leveling system for seismic sensor is necessary. The broadband seismic senor has cylinder shape with diameter of 90 mm and height of 100 mm, and the developed levelling system can mount the seismic sensor with no modification of shape. The levelling system has diameter of 160 mm and height of 110 mm, which is the same size as existing levelling system of the LT-OBS. The levelling system has two horizontal axes and each axis is driven by motor. Leveling can be performed up to 20 degrees by using micro-processor (Arduino). Resolution of levelling is less than one degree. The system immediately starts leveling by the power-on of controller. After levelling, the the seismic senor is powered and the controller records angles of levelling to SD RAM. Then the controller is shut down to consume no power. Compact long-term broadband ocean bottom seismometer is useful for observation of slow earthquakes on seafloor. In addition, seafloor observations of teleseismic events and deep earthquakes to estimate seismic structure of deep regions and observations of submarine volcanoes are expected.
Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations.
N Genikomsakis, Konstantinos; Galatoulas, Nikolaos-Fivos; I Dallas, Panagiotis; Candanedo Ibarra, Luis Miguel; Margaritis, Dimitris; S Ioakimidis, Christos
2018-04-01
Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (PM), in particular fine particles with a diameter of 2.5 μm or less (PM2.5). Specifically, this paper presents the on-field testing of the proposed low-cost APMS implementation using roadside measurements from a mobile laboratory equipped with a calibrated instrument as the basis of comparison and showcases its accuracy on characterizing the PM2.5 concentrations on 1 min resolution in an on-road trial. Moreover, it demonstrates the intended application of collecting fine-grained spatio-temporal PM2.5 profiles by mounting the developed APMS on an electric bike as a case study in the city of Mons, Belgium.
Development and On-Field Testing of Low-Cost Portable System for Monitoring PM2.5 Concentrations
Galatoulas, Nikolaos-Fivos; I. Dallas, Panagiotis; Candanedo Ibarra, Luis Miguel; Margaritis, Dimitris; S. Ioakimidis, Christos
2018-01-01
Recent developments in the field of low-cost sensors enable the design and implementation of compact, inexpensive and portable sensing units for air pollution monitoring with fine-detailed spatial and temporal resolution, in order to support applications of wider interest in the area of intelligent transportation systems (ITS). In this context, the present work advances the concept of developing a low-cost portable air pollution monitoring system (APMS) for measuring the concentrations of particulate matter (PM), in particular fine particles with a diameter of 2.5 μm or less (PM2.5). Specifically, this paper presents the on-field testing of the proposed low-cost APMS implementation using roadside measurements from a mobile laboratory equipped with a calibrated instrument as the basis of comparison and showcases its accuracy on characterizing the PM2.5 concentrations on 1 min resolution in an on-road trial. Moreover, it demonstrates the intended application of collecting fine-grained spatio-temporal PM2.5 profiles by mounting the developed APMS on an electric bike as a case study in the city of Mons, Belgium. PMID:29614770
Raytheon's next generation compact inline cryocooler architecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer, B. R.; Bellis, L.; Ellis, M. J.
2014-01-29
Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These advanced cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Today, sensors face a multitude of cryocooler integration challenges such as exported disturbance, efficiency, scalability, maturity, and cost. As a result, cryocooler selection is application dependent, oftentimes requiring extensive trade studies to determinemore » the most suitable architecture. To optimally meet the needs of next generation passive IR sensors, the Compact Inline Raytheon Stirling 1-Stage (CI-RS1), Compact Inline Raytheon Single Stage Pulse Tube (CI-RP1) and Compact Inline Raytheon Hybrid Stirling/Pulse Tube 2-Stage (CI-RSP2) cryocoolers are being developed to satisfy this suite of requirements. This lightweight, compact, efficient, low vibration cryocooler combines proven 1-stage (RS1 or RP1) and 2-stage (RSP2) cold-head architectures with an inventive set of warm-end mechanisms into a single cooler module, allowing the moving mechanisms for the compressor and the Stirling displacer to be consolidated onto a common axis and in a common working volume. The CI cryocooler is a significant departure from the current Stirling cryocoolers in which the compressor mechanisms are remote from the Stirling displacer mechanism. Placing all of the mechanisms in a single volume and on a single axis provides benefits in terms of package size (30% reduction), mass (30% reduction), thermodynamic efficiency (>20% improvement) and exported vibration performance (≤25 mN peak in all three orthogonal axes at frequencies from 1 to 500 Hz). The main benefit of axial symmetry is that proven balancing techniques and hardware can be utilized to null all motion along the common axis. Low vibration translates to better sensor performance resulting in simpler, more direct mechanical mounting configurations, eliminating the need for convoluted, expensive, massive, long lead damping hardware.« less
Raytheon's next generation compact inline cryocooler architecture
NASA Astrophysics Data System (ADS)
Schaefer, B. R.; Bellis, L.; Ellis, M. J.; Conrad, T.
2014-01-01
Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These advanced cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Today, sensors face a multitude of cryocooler integration challenges such as exported disturbance, efficiency, scalability, maturity, and cost. As a result, cryocooler selection is application dependent, oftentimes requiring extensive trade studies to determine the most suitable architecture. To optimally meet the needs of next generation passive IR sensors, the Compact Inline Raytheon Stirling 1-Stage (CI-RS1), Compact Inline Raytheon Single Stage Pulse Tube (CI-RP1) and Compact Inline Raytheon Hybrid Stirling/Pulse Tube 2-Stage (CI-RSP2) cryocoolers are being developed to satisfy this suite of requirements. This lightweight, compact, efficient, low vibration cryocooler combines proven 1-stage (RS1 or RP1) and 2-stage (RSP2) cold-head architectures with an inventive set of warm-end mechanisms into a single cooler module, allowing the moving mechanisms for the compressor and the Stirling displacer to be consolidated onto a common axis and in a common working volume. The CI cryocooler is a significant departure from the current Stirling cryocoolers in which the compressor mechanisms are remote from the Stirling displacer mechanism. Placing all of the mechanisms in a single volume and on a single axis provides benefits in terms of package size (30% reduction), mass (30% reduction), thermodynamic efficiency (>20% improvement) and exported vibration performance (≤25 mN peak in all three orthogonal axes at frequencies from 1 to 500 Hz). The main benefit of axial symmetry is that proven balancing techniques and hardware can be utilized to null all motion along the common axis. Low vibration translates to better sensor performance resulting in simpler, more direct mechanical mounting configurations, eliminating the need for convoluted, expensive, massive, long lead damping hardware.
Power Electronics Packaging Reliability | Transportation Research | NREL
interface materials, are a key enabling technology for compact, lightweight, low-cost, and reliable power , reliability, and cost. High-temperature bonded interface materials are an important facilitating technology for compact, lightweight, low-cost, reliable power electronics packaging that fully utilizes the
Low loss hollow-core waveguide on a silicon substrate
NASA Astrophysics Data System (ADS)
Yang, Weijian; Ferrara, James; Grutter, Karen; Yeh, Anthony; Chase, Chris; Yue, Yang; Willner, Alan E.; Wu, Ming C.; Chang-Hasnain, Connie J.
2012-07-01
Optical-fiber-based, hollow-core waveguides (HCWs) have opened up many new applications in laser surgery, gas sensors, and non-linear optics. Chip-scale HCWs are desirable because they are compact, light-weight and can be integrated with other devices into systems-on-a-chip. However, their progress has been hindered by the lack of a low loss waveguide architecture. Here, a completely new waveguiding concept is demonstrated using two planar, parallel, silicon-on-insulator wafers with high-contrast subwavelength gratings to reflect light in-between. We report a record low optical loss of 0.37 dB/cm for a 9-μm waveguide, mode-matched to a single mode fiber. Two-dimensional light confinement is experimentally realized without sidewalls in the HCWs, which is promising for ultrafast sensing response with nearly instantaneous flow of gases or fluids. This unique waveguide geometry establishes an entirely new scheme for low-cost chip-scale sensor arrays and lab-on-a-chip applications.
Nanostructure Engineered Chemical Sensors for Hazardous Gas and Vapor Detection
NASA Technical Reports Server (NTRS)
Li, Jing; Lu, Yijiang
2005-01-01
A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxides nanowires or nanobelts, on a pair of interdigitated electrodes (IDE) processed with a silicon based microfabrication and micromachining technique. The IDE fingers were fabricated using thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to hazardous gases and vapors, such as acetone, benzene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing in our sensor platform can be understood by electron modulation between the nanostructure engineered device and gas molecules. As a result of the electron modulation, the conductance of nanodevice will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost.
Roughness sensor based on a compact optoelectronic emitter-receiver modules
NASA Astrophysics Data System (ADS)
Will, Matthias; Brodersen, Olaf; Steinke, Arndt
2012-04-01
In construction and manufacturing the surface roughness and their control plays a major role. The mechanical test probes are used in many applications, because the advantage of the higher resolution of optical systems often plays no role. But in all cases the measurement systems were uses outside of fabrication processes due to the complex and expensive equipment. To overcome these we developed a roughness sensor suitable for an automated control of machined surfaces. The sensor is able to handle high throughput and parallel systems is due to the low cost available. Our solution is compact stand-alone sensors that can be simple integrated in existing systems like machine tools or transport systems. The sensor is based on a diode laser, focusing optics and a special silicon photo diode array in a stable housing. The single-mode VCSEL at 670 nm emission wavelength is focused on the surface of the sample at distance of 5mm. The light was reflected from the test surface and detected with an 8-channel photodiode array. The position of the main reflex allows an optimization of the sensor distance to the surface. During the movement of the sample with a known velocity roughness depended signals over time were recorded at 8 cannels. This allows a detection of the angular distribution of the scattered light in combination of position dependent refection. It was shown here that we be able to achieve resolution below the spot diameter (30μm FWHM). We verify the sensor capabilities for real world applications on drilled samples with typical roughness variations in micro meter range.
Miniaturized spectrometer for stand-off chemical detection
NASA Astrophysics Data System (ADS)
Henning, Patrick F.; Chadha, Suneet; Damren, Richard; Rowe, Rebecca C.; Stevenson, Chuck; Curtiss, Lawrence E.; DiGiuseppe, Thomas G.
2002-02-01
Advanced autonomous detection of both chemical warfare agents and toxic industrial chemicals has long been of major military concern and is becoming an increasingly realistic need. Foster-Miller has successfully designed and demonstrated a high spectral throughput monolithic wedge spectrometer capable of providing early, stand-off detection of chemical threats. Recent breakthrough innovations in IR source technologies, high D* multispectral array detectors, and IR waveguide materials has allowed for the development of a robust, miniature, monolithic infrared spectrometer. Foster-Miller recently demonstrated a high resolution spectrometer operating in the 8 to 12 micron region for chemical agent detection. Results will be presented demonstrating the feasibility of adapting the wedge spectrometer to operate as an upward looking ground sensor for stand-off chemical detection. Our miniaturized spectrometer forms the basis for deploying low cost, lightweight sensors which may be used for reconnaissance missions or delivered to remote locations for unattended operation. The ability of perform passive stand-off infrared chemical agent and chemical emissions detection with a low cost, compact device that can operate autonomously in remote environments has broad applications in both the military and commercial marketplace.
The application of Fresnel zone plate based projection in optofluidic microscopy.
Wu, Jigang; Cui, Xiquan; Lee, Lap Man; Yang, Changhuei
2008-09-29
Optofluidic microscopy (OFM) is a novel technique for low-cost, high-resolution on-chip microscopy imaging. In this paper we report the use of the Fresnel zone plate (FZP) based projection in OFM as a cost-effective and compact means for projecting the transmission through an OFM's aperture array onto a sensor grid. We demonstrate this approach by employing a FZP (diameter = 255 microm, focal length = 800 microm) that has been patterned onto a glass slide to project the transmission from an array of apertures (diameter = 1 microm, separation = 10 microm) onto a CMOS sensor. We are able to resolve the contributions from 44 apertures on the sensor under the illumination from a HeNe laser (wavelength = 633 nm). The imaging quality of the FZP determines the effective field-of-view (related to the number of resolvable transmissions from apertures) but not the image resolution of such an OFM system--a key distinction from conventional microscope systems. We demonstrate the capability of the integrated system by flowing the protist Euglena gracilis across the aperture array microfluidically and performing OFM imaging of the samples.
Uncertainty in air quality observations using low-cost sensors
NASA Astrophysics Data System (ADS)
Castell, Nuria; Dauge, Franck R.; Dongol, Rozina; Vogt, Matthias; Schneider, Philipp
2016-04-01
Air pollution poses a threat to human health, and the WHO has classified air pollution as the world's largest single environmental health risk. In Europe, the majority of the population lives in areas where air quality levels frequently exceed WHO's ambient air quality guidelines. The emergence of low-cost, user-friendly and very compact air pollution platforms allowing observations at high spatial resolution in near real-time, provides us with new opportunities to simultaneously enhance existing monitoring systems as well as enable citizens to engage in more active environmental monitoring (citizen science). However the data sets generated by low-cost sensors show often questionable data quality. For many sensors, neither their error characteristics nor how their measurement capability holds up over time or through a range of environmental conditions, have been evaluated. We have conducted an exhaustive evaluation of the commercial low-cost platform AQMesh (measuring NO, NO2, CO, O3, PM10 and PM2.5) in laboratory and in real-world conditions in the city of Oslo (Norway). Co-locations in field of 24 platforms were conducted over a 6 month period (April to September 2015) allowing to characterize the temporal variability in the performance. Additionally, the field performance included the characterization on different monitoring urban monitoring sites characteristic of both traffic and background conditions. All the evaluations have been conducted against CEN reference method analyzers maintained according to the Norwegian National Reference Laboratory quality system. The results show clearly that a good performance in laboratory does not imply similar performance in real-world outdoor conditions. Moreover, laboratory calibration is not suitable for subsequent measurements in urban environments. In order to reduce the errors, sensors require on-site field calibration. Even after such field calibration, the platforms show a significant variability in the performance due to changes in the environmental conditions. Currently there is a lack of testing to ensure adequate sensor performance prior to marketing such instruments. Even when manufacturers provide detailed specification sheets, there is little guarantee that the specifications can actually be met in real-world conditions. Data quality is a pertinent concern, especially when citizens are collecting and interpreting the data by themselves. Poor or unknown data quality can lead to incorrect or inappropriate decisions. We present the experiences gained within the EU project CITI-SENSE, where low-cost sensors are one of the tools employed to empower citizens in air quality issues.
Thurmond, Kyle; Loparo, Zachary; Partridge, William; Vasu, Subith S
2016-06-01
A sensor was developed for simultaneous measurements of carbon monoxide (CO) and carbon dioxide (CO2) fluctuations in internal combustion engine exhaust gases. This sensor utilizes low-cost and compact light-emitting diodes (LEDs) that emit in the 3-5 µm wavelength range. An affordable, fast response sensor that can measure these gases has a broad application that can lead to more efficient, fuel-flexible engines and regulation of harmful emissions. Light emission from LEDs is spectrally broader and more spatially divergent when compared to that of lasers, which presented many design challenges. Optical design studies addressed some of the non-ideal characteristics of the LED emissions. Measurements of CO and CO2 were conducted using their fundamental absorption bands centered at 4.7 µm and 4.3 µm, respectively, while a 3.6 µm reference LED was used to account for scattering losses (due to soot, window deposits, etc.) common to the three measurement LEDs. Instrument validation and calibration was performed using a laboratory flow cell and bottled-gas mixtures. The sensor was able to detect CO2 and CO concentration changes as small as 30 ppm and 400 ppm, respectively. Because of the many control and monitor species with infra-red absorption features, which can be measured using the strategy described, this work demonstrates proof of concept for a wider range of fast (250 Hz) and low-cost sensors for gas measurement and process monitoring. © The Author(s) 2016.
Citizen Science Air Monitoring in the Ironbound Community ...
The Environmental Protection Agency’s (EPA) mission is to protect human health and the environment. To move toward achieving this goal, EPA is facilitating identification of potential environmental concerns, particularly in vulnerable communities. This includes actively supporting citizen science projects and providing communities with the information and assistance they need to conduct their own air pollution monitoring efforts. The Air Sensor Toolbox for Citizen Scientists1 was developed as a resource to meet stakeholder needs. Examples of materials developed for the Toolbox and ultimately pilot tested in the Ironbound Community in Newark, New Jersey are reported here. The Air Sensor Toolbox for Citizen Scientists is designed as an online resource that provides information and guidance on new, low-cost compact technologies used for measuring air quality. The Toolbox features resources developed by EPA researchers that can be used by citizens to effectively collect, analyze, interpret, and communicate air quality data. The resources include information about sampling methods, how to calibrate and validate monitors, options for measuring air quality, data interpretation guidelines, and low-cost sensor performance information. This Regional Applied Research Effort (RARE) project provided an opportunity for the Office of Research and Development (ORD) to work collaboratively with EPA Region 2 to provide the Ironbound Community with a “Toolbox” specific for c
A New Black Carbon Sensor for Dense Air Quality Monitoring Networks
Caubel, Julien J.; Cados, Troy E.; Kirchstetter, Thomas W.
2018-01-01
Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)—a major component of particulate matter pollution associated with adverse human health risks—is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD’s sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval). PMID:29494528
A New Black Carbon Sensor for Dense Air Quality Monitoring Networks.
Caubel, Julien J; Cados, Troy E; Kirchstetter, Thomas W
2018-03-01
Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)-a major component of particulate matter pollution associated with adverse human health risks-is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD's sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval).
Wireless Zigbee strain gage sensor system for structural health monitoring
NASA Astrophysics Data System (ADS)
Ide, Hiroshi; Abdi, Frank; Miraj, Rashid; Dang, Chau; Takahashi, Tatsuya; Sauer, Bruce
2009-05-01
A compact cell phone size radio frequency (ZigBee) wireless strain measurement sensor system to measure the structural strain deformation was developed. The developed system provides an accurate strain measurement data stream to the Internet for further Diagnostic and Prognostic (DPS) correlation. Existing methods of structural measurement by strain sensors (gauges) do not completely satisfy problems posed by continuous structural health monitoring. The need for efficient health monitoring methods with real-time requirements to bidirectional data flow from sensors and to a commanding device is becoming critical for keeping our daily life safety. The use of full-field strain measurement techniques could reduce costly experimental programs through better understanding of material behavior. Wireless sensor-network technology is a monitoring method that is estimated to grow rapidly providing potential for cost savings over traditional wired sensors. The many of currently available wireless monitoring methods have: the proactive and constant data rate character of the data streams rather than traditional reactive, event-driven data delivery; mostly static node placement on structures with limited number of nodes. Alpha STAR Electronics' wireless sensor network system, ASWN, addresses some of these deficiencies, making the system easier to operate. The ASWN strain measurement system utilizes off-the-shelf sensors, namely strain gauges, with an analog-to-digital converter/amplifier and ZigBee radio chips to keep cost lower. Strain data is captured by the sensor, converted to digital form and delivered to the ZigBee radio chip, which in turn broadcasts the information using wireless protocols to a Personal Data Assistant (PDA) or Laptop/Desktop computers. From here, data is forwarded to remote computers for higher-level analysis and feedback using traditional cellular and satellite communication or the Ethernet infrastructure. This system offers a compact size, lower cost, and temperature insensitivity for critical structural applications, which require immediate monitoring and feedback.
NASA Astrophysics Data System (ADS)
Ben Mohammadi, L.; Kullmann, F.; Holzki, M.; Sigloch, S.; Klotzbuecher, T.; Spiesen, J.; Tommingas, T.; Weismann, P.; Kimber, G.
2010-04-01
The chemical and physical condition of oils in marine engines must be monitored to ensure optimum performance of the engine and to avoid damage by degraded oil not adequately lubricating the engine. Routine monitoring requires expensive laboratory testing and highly skilled analysts. This work describes the adaptation and implementation of a mid infrared (MIR) sensor module for continued oil condition monitoring in two-stroke and four-stroke diesel engines. The developed sensor module will help to reduce costs in oil analysis by eliminating the need to collect and send samples to a laboratory for analysis. The online MIR-Sensor module measures the contamination of oil with water, soot, as well as the degradation indicated by the TBN (Total Base Number) value. For the analysis of water, TBN, and soot in marine engine oils, four spectral regions of interest have been identified. The optical absorption in these bands correlating with the contaminations is measured simultaneously by using a four-field thermopile detector, combined with appropriate bandpass filters. Recording of the MIR-absorption was performed in a transmission mode using a flow-through cell with appropriate path length. Since in this case no spectrometer is required, the sensor including the light source, the flowthrough- cell, and the detector can be realised at low cost and in a very compact manner. The optical configuration of the sensor with minimal component number and signal intensity optimisation at the four-field detector was implemented by using non-sequential ray tracing simulation. The used calibration model was robust enough to predict accurately the value for soot, water, and TBN concentration for two-stroke and four-stroke engine oils. The sensor device is designed for direct installation on the host engine or machine and, therefore, becoming an integral part of the lubrication system. It can also be used as a portable stand-alone system for machine fluid analysis in the field.
A simple and low-cost biofilm quantification method using LED and CMOS image sensor.
Kwak, Yeon Hwa; Lee, Junhee; Lee, Junghoon; Kwak, Soo Hwan; Oh, Sangwoo; Paek, Se-Hwan; Ha, Un-Hwan; Seo, Sungkyu
2014-12-01
A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive. Biofilms originating from various bacterial strains, including Pseudomonas aeruginosa (P. aeruginosa), were tested to demonstrate the efficacy of this new biofilm detection approach. The results were compared with the results obtained from a commercial spectrophotometer. To utilize a cost-effective light source (i.e., an LED) for biofilm detection, the illumination conditions were optimized. For accurate and reproducible biofilm detection, a simple, custom-coded image processing algorithm was developed and applied to a five-megapixel CMOS image sensor, which is a cost-effective detector. The concentration of biofilms formed by P. aeruginosa was detected and quantified by varying the indole concentration, and the results were compared with the results obtained from a commercial spectrophotometer. The correlation value of the results from those two systems was 0.981 (N = 9, P < 0.01) and the coefficients of variation (CVs) were approximately threefold lower at the CMOS image-sensor platform. Copyright © 2014 Elsevier B.V. All rights reserved.
Adaptive Inner-Loop Rover Control
NASA Technical Reports Server (NTRS)
Kulkarni, Nilesh; Ippolito, Corey; Krishnakumar, Kalmanje; Al-Ali, Khalid M.
2006-01-01
Adaptive control technology is developed for the inner-loop speed and steering control of the MAX Rover. MAX, a CMU developed rover, is a compact low-cost 4-wheel drive, 4-wheel steer (double Ackerman), high-clearance agile durable chassis, outfitted with sensors and electronics that make it ideally suited for supporting research relevant to intelligent teleoperation and as a low-cost autonomous robotic test bed and appliance. The design consists of a feedback linearization based controller with a proportional - integral (PI) feedback that is augmented by an online adaptive neural network. The adaptation law has guaranteed stability properties for safe operation. The control design is retrofit in nature so that it fits inside the outer-loop path planning algorithms. Successful hardware implementation of the controller is illustrated for several scenarios consisting of actuator failures and modeling errors in the nominal design.
A smart microelectromechanical sensor and switch triggered by gas
NASA Astrophysics Data System (ADS)
Bouchaala, Adam; Jaber, Nizar; Shekhah, Osama; Chernikova, Valeriya; Eddaoudi, Mohamed; Younis, Mohammad I.
2016-07-01
There is an increasing interest to realize smarter sensors and actuators that can deliver a multitude of sophisticated functionalities while being compact in size and of low cost. We report here combining both sensing and actuation on the same device based on a single microstructure. Specifically, we demonstrate a smart resonant gas (mass) sensor, which in addition to being capable of quantifying the amount of absorbed gas, can be autonomously triggered as an electrical switch upon exceeding a preset threshold of absorbed gas. Toward this, an electrostatically actuated polymer microbeam is fabricated and is then functionalized with a metal-organic framework, namely, HKUST-1. The microbeam is demonstrated to absorb vapors up to a certain threshold, after which is shown to collapse through the dynamic pull-in instability. Upon pull-in, the microstructure can be made to act as an electrical switch to achieve desirable actions, such as alarming.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Xiangzhi, E-mail: xiangzhi.yu@rochester.edu; Gillmer, Steven R.; Woody, Shane C.
2016-06-15
A compact, fiber-coupled, six degree-of-freedom measurement system which enables fast, accurate calibration, and error mapping of precision linear stages is presented. The novel design has the advantages of simplicity, compactness, and relatively low cost. This proposed sensor can simultaneously measure displacement, two straightness errors, and changes in pitch, yaw, and roll using a single optical beam traveling between the measurement system and a small target. The optical configuration of the system and the working principle for all degrees-of-freedom are presented along with the influence and compensation of crosstalk motions in roll and straightness measurements. Several comparison experiments are conducted tomore » investigate the feasibility and performance of the proposed system in each degree-of-freedom independently. Comparison experiments to a commercial interferometer demonstrate error standard deviations of 0.33 μm in straightness, 0.14 μrad in pitch, 0.44 μradin yaw, and 45.8 μrad in roll.« less
Fiber Bragg grating strain sensors to monitor and study active volcanoes
NASA Astrophysics Data System (ADS)
Sorrentino, Fiodor; Beverini, Nicolò; Carbone, Daniele; Carelli, Giorgio; Francesconi, Francesco; Gambino, Salvo; Giacomelli, Umberto; Grassi, Renzo; Maccioni, Enrico; Morganti, Mauro
2016-04-01
Stress and strain changes are among the best indicators of impending volcanic activity. In volcano geodesy, borehole volumetric strain-meters are mostly utilized. However, they are not easy to install and involve high implementation costs. Advancements in opto-electronics have allowed the development of low-cost sensors, reliable, rugged and compact, thus particularly suitable for field application. In the framework of the EC FP7 MED-SUV project, we have developed strain sensors based on the fiber Bragg grating (FBG) technology. In comparison with previous implementation of the FBG technology to study rock deformations, we have designed a system that is expected to offer a significantly higher resolution and accuracy in static measurements and a smooth dynamic response up to 100 Hz, implying the possibility to observe seismic waves. The system performances are tailored to suit the requirements of volcano monitoring, with special attention to power consumption and to the trade-off between performance and cost. Preliminary field campaigns were carried out on Mt. Etna (Italy) using a prototypal single-axis FBG strain sensor, to check the system performances in out-of-the-lab conditions and in the harsh volcanic environment (lack of mains electricity for power, strong diurnal temperature changes, strong wind, erosive ash, snow and ice during the winter time). We also designed and built a FBG strain sensor featuring a multi-axial configuration which was tested and calibrated in the laboratory. This instrument is suitable for borehole installation and will be tested on Etna soon.
A multi-core fiber based interferometer for high temperature sensing
NASA Astrophysics Data System (ADS)
Zhou, Song; Huang, Bo; Shu, Xuewen
2017-04-01
In this paper, we have verified and implemented a Mach-Zehnder interferometer based on seven-core fiber for high temperature sensing application. This proposed structure is based on a multi-mode-multi-core-multi-mode fiber structure sandwiched by a single mode fiber. Between the single-mode and multi-core fiber, a 3 mm long multi-mode fiber is formed for lead-in and lead-out light. The basic operation principle of this device is the use of multi-core modes, single-mode and multi-mode interference coupling is also utilized. Experimental results indicate that this interferometer sensor is capable of accurate measurements of temperatures up to 800 °C, and the temperature sensitivity of the proposed sensor is as high as 170.2 pm/°C, which is much higher than the current existing MZI based temperature sensors (109 pm/°C). This type of sensor is promising for practical high temperature applications due to its advantages including high sensitivity, simple fabrication process, low cost and compactness.
Liao, Yu-Yang; Chen, Yung-Tsan; Chen, Chien-Chun; Huang, Jian-Jang
2018-04-03
The sensitivity of traditional diffraction grating sensors is limited by the spatial resolution of the measurement setup. Thus, a large space is required to improve sensor performance. Here, we demonstrate a compact hexagonal photonic crystal (PhC) optical sensor with high sensitivity. PhCs are able to diffract optical beams to various angles in azimuthal space. The critical wavelength that satisfies the phase matching or becomes evanescent was used to benchmark the refractive index of a target analyte applied on a PhC sensor. Using a glucose solution as an example, our sensor demonstrated very high sensitivity and a low limit of detection. This shows that the diffraction mechanism of hexagonal photonic crystals can be used for sensors when compact size is a concern.
NASA Astrophysics Data System (ADS)
Kraker, E.; Lamprecht, B.; Haase, A.; Jakopic, G.; Abel, T.; Konrad, C.; Köstler, S.; Tscherner, M.; Stadlober, B.; Mayr, T.
2010-08-01
A compact, integrated photoluminescence based oxygen sensor, utilizing an organic light emitting device (OLED) as the light source and an organic photodiode (OPD) as the detection unit, is described. The detection system of the sensor array consists of an array of circular screen-printed fluorescent sensor spots surrounded by organic photodiodes as integrated fluorescence detectors. The OPD originates from the well-known Tang photodiode, consisting of a stacked layer of copper phthalocyanine (CuPc, p-type material) and perylene tetracarboxylic bisbenzimidazole (PTCBi, n-type material). An additional layer of tris-8-hydroxyquinolinatoaluminium (Alq3, n-type material) was inserted between the PTCBi layer and cathode. An ORMOCERR layer was used as encapsulation layer. For excitation an organic light emitting diode is used. The sensor spot and the detector are processed on the same flexible substrate. This approach not only simplifies the detection system by minimizing the numbers of required optical components - no optical filters have to be used for separating the excitation light and the luminescent emission-, but also has a large potential for low-cost sensor applications. The feasibility of the concept is demonstrated by an integrated oxygen sensor, indicating good performance. Sensor schemes for other chemical parameters are proposed.
A graphene-based Fabry-Pérot spectrometer in mid-infrared region
Wang, Xiaosai; Chen, Chen; Pan, Liang; Wang, Jicheng
2016-01-01
Mid-infrared spectroscopy is of great importance in many areas and its integration with thin-film technology can economically enrich the functionalities of many existing devices. In this paper we propose a graphene-based ultra-compact spectrometer (several micrometers in size) that is compatible with complementary metal-oxide-semiconductor (CMOS) processing. The proposed structure uses a monolayer graphene as a mid-infrared surface waveguide, whose optical response is spatially modulated using electric fields to form a Fabry-Pérot cavity. By varying the voltage acting on the cavity, we can control the transmitted wavelength of the spectrometer at room temperature. This design has potential applications in the graphene-silicon-based optoelectronic devices as it offers new possibilities for developing new ultra-compact spectrometers and low-cost hyperspectral imaging sensors in mid-infrared region. PMID:27573080
Confocal epifluorescence sensor with an arc-shaped aperture for slide-based PCR quantification.
Weng, Jui-Hong; Chen, Lin-Chi
2018-02-15
The increasing needs of point-of-care diagnostics, quarantine of epidemic pathogens, and prevention of terrorism's bio-attacks have promised the future of portable real-time quantitative polymerase chain reaction (qPCR) sensors. This work aims at developing a highly sensitive and low-cost light emitting diode (LED)-based epifluorescence sensor module for qPCR sensor development and relevant bioassay applications. Inspired by the light stop design and dark-field detection of microscopes, this paper first reports a compact confocal LED epifluorescence sensor using a light stop with an arc-shaped aperture for enhancing the flexibility of quick DNA and PCR detection. The sensor features the advantages of the dichroic mirror-free and confocal (shared-focus) characteristics, which benefits size reduction and minimal optics used. It also allows extension to integrate with in situ real-time PCR thermal cycling since the sample slide is placed apart from the epi-sensing module. The epifluorescence sensor can detect as low as sub-ng/μL standard DNA and 10 1 copies of Salmonella typhimurium InvA gene sequences (cloned in E. coli and after 30-cycle PCR) with SYBR ® Green I from non-purified culture samples, having highly sensitive and specific signal responses comparable with that of a commercial qPCR instrument. Copyright © 2017 Elsevier B.V. All rights reserved.
A Wireless Sensor System for Real-Time Monitoring and Fault Detection of Motor Arrays
Medina-García, Jonathan; Sánchez-Rodríguez, Trinidad; Galán, Juan Antonio Gómez; Delgado, Aránzazu; Gómez-Bravo, Fernando; Jiménez, Raúl
2017-01-01
This paper presents a wireless fault detection system for industrial motors that combines vibration, motor current and temperature analysis, thus improving the detection of mechanical faults. The design also considers the time of detection and further possible actions, which are also important for the early detection of possible malfunctions, and thus for avoiding irreversible damage to the motor. The remote motor condition monitoring is implemented through a wireless sensor network (WSN) based on the IEEE 802.15.4 standard. The deployed network uses the beacon-enabled mode to synchronize several sensor nodes with the coordinator node, and the guaranteed time slot mechanism provides data monitoring with a predetermined latency. A graphic user interface offers remote access to motor conditions and real-time monitoring of several parameters. The developed wireless sensor node exhibits very low power consumption since it has been optimized both in terms of hardware and software. The result is a low cost, highly reliable and compact design, achieving a high degree of autonomy of more than two years with just one 3.3 V/2600 mAh battery. Laboratory and field tests confirm the feasibility of the wireless system. PMID:28245623
A Wireless Sensor System for Real-Time Monitoring and Fault Detection of Motor Arrays.
Medina-García, Jonathan; Sánchez-Rodríguez, Trinidad; Galán, Juan Antonio Gómez; Delgado, Aránzazu; Gómez-Bravo, Fernando; Jiménez, Raúl
2017-02-25
This paper presents a wireless fault detection system for industrial motors that combines vibration, motor current and temperature analysis, thus improving the detection of mechanical faults. The design also considers the time of detection and further possible actions, which are also important for the early detection of possible malfunctions, and thus for avoiding irreversible damage to the motor. The remote motor condition monitoring is implemented through a wireless sensor network (WSN) based on the IEEE 802.15.4 standard. The deployed network uses the beacon-enabled mode to synchronize several sensor nodes with the coordinator node, and the guaranteed time slot mechanism provides data monitoring with a predetermined latency. A graphic user interface offers remote access to motor conditions and real-time monitoring of several parameters. The developed wireless sensor node exhibits very low power consumption since it has been optimized both in terms of hardware and software. The result is a low cost, highly reliable and compact design, achieving a high degree of autonomy of more than two years with just one 3.3 V/2600 mAh battery. Laboratory and field tests confirm the feasibility of the wireless system.
Photoacoustic sensor for medical diagnostics
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann
2004-03-01
The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.
NASA Astrophysics Data System (ADS)
Sahatiya, Parikshit; Badhulika, Sushmee
2017-03-01
This paper reports a new type of electronic, recoverable skin-like pressure and strain sensor, produced on a flexible, biodegradable pencil-eraser substrate and fabricated using a solvent-free, low-cost and energy efficient process. Multi-walled carbon nanotube (MWCNT) film, the strain sensing element, was patterned on pencil eraser with a rolling pin and a pre-compaction mechanical press. This induces high interfacial bonding between the MWCNTs and the eraser substrate, which enables the sensor to achieve recoverability under ambient conditions. The eraser serves as a substrate for strain sensing, as well as acting as a dielectric for capacitive pressure sensing, thereby eliminating the dielectric deposition step, which is crucial in capacitive-based pressure sensors. The strain sensing transduction mechanism is attributed to the tunneling effect, caused by the elastic behavior of the MWCNTs and the strong mechanical interlock between MWCNTs and the eraser substrate, which restricts slippage of MWCNTs on the eraser thereby minimizing hysteresis. The gauge factor of the strain sensor was calculated to be 2.4, which is comparable to and even better than most of the strain and pressure sensors fabricated with more complex designs and architectures. The sensitivity of the capacitive pressure sensor was found to be 0.135 MPa-1.To demonstrate the applicability of the sensor as artificial electronic skin, the sensor was assembled on various parts of the human body and corresponding movements and touch sensation were monitored. The entire fabrication process is scalable and can be integrated into large areas to map spatial pressure distributions. This low-cost, easily scalable MWCNT pin-rolled eraser-based pressure and strain sensor has huge potential in applications such as artificial e-skin in flexible electronics and medical diagnostics, in particular in surgery as it provides high spatial resolution without a complex nanostructure architecture.
Sahatiya, Parikshit; Badhulika, Sushmee
2017-03-03
This paper reports a new type of electronic, recoverable skin-like pressure and strain sensor, produced on a flexible, biodegradable pencil-eraser substrate and fabricated using a solvent-free, low-cost and energy efficient process. Multi-walled carbon nanotube (MWCNT) film, the strain sensing element, was patterned on pencil eraser with a rolling pin and a pre-compaction mechanical press. This induces high interfacial bonding between the MWCNTs and the eraser substrate, which enables the sensor to achieve recoverability under ambient conditions. The eraser serves as a substrate for strain sensing, as well as acting as a dielectric for capacitive pressure sensing, thereby eliminating the dielectric deposition step, which is crucial in capacitive-based pressure sensors. The strain sensing transduction mechanism is attributed to the tunneling effect, caused by the elastic behavior of the MWCNTs and the strong mechanical interlock between MWCNTs and the eraser substrate, which restricts slippage of MWCNTs on the eraser thereby minimizing hysteresis. The gauge factor of the strain sensor was calculated to be 2.4, which is comparable to and even better than most of the strain and pressure sensors fabricated with more complex designs and architectures. The sensitivity of the capacitive pressure sensor was found to be 0.135 MPa -1 .To demonstrate the applicability of the sensor as artificial electronic skin, the sensor was assembled on various parts of the human body and corresponding movements and touch sensation were monitored. The entire fabrication process is scalable and can be integrated into large areas to map spatial pressure distributions. This low-cost, easily scalable MWCNT pin-rolled eraser-based pressure and strain sensor has huge potential in applications such as artificial e-skin in flexible electronics and medical diagnostics, in particular in surgery as it provides high spatial resolution without a complex nanostructure architecture.
SPR based immunosensor for detection of Legionella pneumophila in water samples
NASA Astrophysics Data System (ADS)
Enrico, De Lorenzis; Manera, Maria G.; Montagna, Giovanni; Cimaglia, Fabio; Chiesa, Maurizio; Poltronieri, Palmiro; Santino, Angelo; Rella, Roberto
2013-05-01
Detection of legionellae by water sampling is an important factor in epidemiological investigations of Legionnaires' disease and its prevention. To avoid labor-intensive problems with conventional methods, an alternative, highly sensitive and simple method is proposed for detecting L. pneumophila in aqueous samples. A compact Surface Plasmon Resonance (SPR) instrumentation prototype, provided with proper microfluidics tools, is built. The developed immunosensor is capable of dynamically following the binding between antigens and the corresponding antibody molecules immobilized on the SPR sensor surface. A proper immobilization strategy is used in this work that makes use of an important efficient step aimed at the orientation of antibodies onto the sensor surface. The feasibility of the integration of SPR-based biosensing setups with microfluidic technologies, resulting in a low-cost and portable biosensor is demonstrated.
Optofluidic Approaches for Enhanced Microsensor Performances
Testa, Genni; Persichetti, Gianluca; Bernini, Romeo
2015-01-01
Optofluidics is a relatively young research field able to create a tight synergy between optics and micro/nano-fluidics. The high level of integration between fluidic and optical elements achievable by means of optofluidic approaches makes it possible to realize an innovative class of sensors, which have been demonstrated to have an improved sensitivity, adaptability and compactness. Many developments in this field have been made in the last years thanks to the availability of a new class of low cost materials and new technologies. This review describes the Italian state of art on optofluidic devices for sensing applications and offers a perspective for further future advances. We introduce the optofluidic concept and describe the advantages of merging photonic and fluidic elements, focusing on sensor developments for both environmental and biomedical monitoring. PMID:25558989
Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis.
Herrera-Piad, Luis A; Haus, Joseph W; Jauregui-Vazquez, Daniel; Sierra-Hernandez, Juan M; Estudillo-Ayala, Julian M; Lopez-Dieguez, Yanelis; Rojas-Laguna, Roberto
2017-10-20
A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.
Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis
Herrera-Piad, Luis A.; Jauregui-Vazquez, Daniel; Sierra-Hernandez, Juan M.; Lopez-Dieguez, Yanelis
2017-01-01
A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material. PMID:29053570
AIRQino, a low-cost air quality mobile platform
NASA Astrophysics Data System (ADS)
Zaldei, Alessandro; Vagnoli, Carolina; Di Lonardo, Sara; Gioli, Beniamino; Gualtieri, Giovanni; Toscano, Piero; Martelli, Francesca; Matese, Alessandro
2015-04-01
Recent air quality regulations (Directive 2008/50/EC) enforce the transition from point-based monitoring networks to new tools that must be capable of mapping and forecasting air quality on the totality of land area, and therefore the totality of citizens. This implies new technologies such as models and additional indicative measurements, are needed in addition to accurate fixed air quality monitoring stations, that until now have been taken as reference by local administrators for the enforcement of various mitigation strategies. However, due to their sporadic spatial distribution, they cannot describe the highly resolved spatial pollutant variations within cities. Integrating additional indicative measurements may provide adequate information on the spatial distribution of the ambient air quality, also allowing for a reduction of the required minimum number of fixed sampling points, whose high cost and complex maintenance still remain a crucial concern for local administrators. New low-cost and small size sensors are becoming available, that could be employed in air quality monitoring including mobile applications. However, accurate assessment of their accuracy and performance both in controlled and real monitoring conditions is crucially needed. Quantifying sensor response is a significant challenge due to the sensitivity to ambient temperature and humidity and the cross-sensitivity to others pollutant species. This study reports the development of an Arduino compatible electronic board (AIRQino) which integrates a series of low-cost metal oxide and NDIR sensors for air quality monitoring, with sensors to measure air temperature, relative humidity, noise, solar radiation and vertical acceleration. A comparative assessment was made for CO2, CO, NO2, CH4, O3, VOCs concentrations, temperature and relative humidity. A controlled climatic chamber study (-80°C / +80°C) was performed to verify temperature and humidity interference using reference gas cylinders and high quality reference sensors. The AIRQino was installed on mobile vectors such as bikes, buses and trams in the cities of Firenze and Siracusa (Italy), that send data real-time to a Web portal. By integrating a microprocessor unit it is capable of directly updating calibration coefficients to provide corrected sensor output as digital string through RS232 serial port. Results from the lab tests and the 'real world' mobile applications are presented and discussed, to assess to what extent this sensor technology might be useful for the development of portable, compact, wireless and cost-effective system for air quality monitoring in urban areas at high spatio-temporal resolution.
Hybrid MEFPI/FBG sensor for simultaneous measurement of strain and magnetic field
NASA Astrophysics Data System (ADS)
Chen, Mao-qing; Zhao, Yong; Lv, Ri-qing; Xia, Feng
2017-12-01
A hybrid fiber-optic sensor consisting of a micro extrinsic Fabry-Perot Interferometer (MEFPI) and an etched fiber Bragg grating (FBG) is proposed, which can measure strain and magnetic field simultaneously. The etched FBG is sealed in a capillary with ferrofluids to detect the surrounding magnetic field. FBG with small diameter will be more sensitive to magnetic field is confirmed by simulation results. The MEFPI sensor that is prepared through welding a short section of hollow-core fiber (HCF) with single-mode fiber (SMF) is effective for strain detection. The experiment shows that strain and magnetic field can be successfully simultaneously detected based on hybrid MEFPI/FBG sensor. The sensitivities of the strain and magnetic field intensity are measured to be up to 1.41 pm/με and 5.11 pm/mT respectively. There is a negligible effect on each other, hence simultaneously measuring strain and magnetic field is feasible. It is anticipated that such easy preparation, compact and low-cost fiber-optic sensors for simultaneous measurement of strain and magnetic field could find important applications in practice.
Compact high-speed scanning lidar system
NASA Astrophysics Data System (ADS)
Dickinson, Cameron; Hussein, Marwan; Tripp, Jeff; Nimelman, Manny; Koujelev, Alexander
2012-06-01
The compact High Speed Scanning Lidar (HSSL) was designed to meet the requirements for a rover GN&C sensor. The eye-safe HSSL's fast scanning speed, low volume and low power, make it the ideal choice for a variety of real-time and non-real-time applications including: 3D Mapping; Vehicle guidance and Navigation; Obstacle Detection; Orbiter Rendezvous; Spacecraft Landing / Hazard Avoidance. The HSSL comprises two main hardware units: Sensor Head and Control Unit. In a rover application, the Sensor Head mounts on the top of the rover while the Control Unit can be mounted on the rover deck or within its avionics bay. An Operator Computer is used to command the lidar and immediately display the acquired scan data. The innovative lidar design concept was a result of an extensive trade study conducted during the initial phase of an exploration rover program. The lidar utilizes an innovative scanner coupled with a compact fiber laser and high-speed timing electronics. Compared to existing compact lidar systems, distinguishing features of the HSSL include its high accuracy, high resolution, high refresh rate and large field of view. Other benefits of this design include the capability to quickly configure scan settings to fit various operational modes.
NASA Astrophysics Data System (ADS)
Barone, F.; Giordano, G.
2017-09-01
In this paper we describe the characteristics and performances of a monolithic sensor designed for low frequency motion measurement of spacecrafts and satellites, whose mechanics is based on the UNISA Folded Pendulum. The latter, developed for ground-based applications, exhibits unique features (compactness, lightness, scalability, low resonance frequency and high quality factor), consequence of the action of the gravitational force on its inertial mass. In this paper we introduce and discuss the general methodology used to extend the application of ground-based folded pendulums to space, also in total absence of gravity, still keeping all their peculiar features and characteristics.
Compact low-cost detection electronics for optical coherence imaging
Akcay, A. C.; Lee, K. S.; Furenlid, L. R.; Costa, M. A.; Rolland, J. P.
2015-01-01
A compact and low-cost detection electronics scheme for optical coherence imaging is demonstrated. The performance of the designed electronics is analyzed in comparison to a commercial lock-in amplifier of equal bandwidth. Images of a fresh-onion sample are presented for each detection configuration. PMID:26617422
Photonic crystal fiber Fabry-Perot interferometers with high-reflectance internal mirrors
NASA Astrophysics Data System (ADS)
Fan, Rong; Hou, Yuanbin; Sun, Wei
2015-06-01
We demonstrated an in-line micro fiber-optic Fabry-Perot interferometer with an air cavity which was created by multi-step fusion splicing a muti-mode photonic crystal fiber (MPCF) to a standard single mode fiber (SMF). The fringe visibility of the interference pattern was up to 20 dB by reshaping the air cavity. Experimental results showed that such a device could be used as a highly sensitive strain sensor with the sensitivity of 4.5 pm/μɛ. Moreover, it offered some other outstanding advantages, such as the extremely compact structure, easy fabrication, low cost, and high accuracy.
Mixed-mode VLSI optic flow sensors for in-flight control of a micro air vehicle
NASA Astrophysics Data System (ADS)
Barrows, Geoffrey L.; Neely, C.
2000-11-01
NRL is developing compact optic flow sensors for use in a variety of small-scale navigation and collision avoidance tasks. These sensors are being developed for use in micro air vehicles (MAVs), which are autonomous aircraft whose maximum dimension is on the order of 15 cm. To achieve desired weight specifications of 1 - 2 grams, mixed-signal VLSI circuitry is being used to develop compact focal plane sensors that directly compute optic flow. As an interim proof of principle, we have constructed a sensor comprising a focal plane sensor head with on-chip processing and a back-end PIC microcontroller. This interim sensors weighs approximately 25 grams and is able to measure optic flow with real-world and low-contrast textures. Variations of this sensor have been used to control the flight of a glider in real-time to avoid collisions with walls.
Nanostructured plasmonic interferometers for ultrasensitive label-free biosensing
NASA Astrophysics Data System (ADS)
Gao, Yongkang
Optical biosensors that utilize surface plasmon resonance (SPR) technique to analyze the biomolecular interactions have been extensively explored in the last two decades and have become the gold standard for label-free biosensing. These powerful sensing tools allow fast, highly-sensitive monitoring of the interaction between biomolecules in real time, without the need for laborious fluorescent labeling, and have found widely ranging applications from biomedical diagnostics and drug discovery, to environmental sensing and food safety monitoring. However, the prism-coupling SPR geometry is complex and bulky, and has severely limited the integration of this technique into low-cost portable biomedical devices for point-of-care diagnostics and personal healthcare applications. Also, the complex prism-coupling scheme prevents the use of high numerical aperture (NA) optics to increase the spatial resolution for multi-channel, high-throughput detection in SPR imaging mode. This dissertation is focused on the design and fabrication of a promising new class of nanopatterned interferometric SPR sensors that integrate the strengths of miniaturized nanoplasmonic architectures with sensitive optical interferometry techniques to achieve bold advances in SPR biosensing. The nanosensor chips developed provide superior sensing performance comparable to conventional SPR systems, but employing a far simpler collinear optical transmission geometry, which largely facilitates system integration, miniaturization, and low-cost production. Moreover, the fabricated nanostructure-based SPR sensors feature a very small sensor footprint, allowing massive multiplexing on a chip for high-throughput detection. The successful transformation of SPR technique from bulky prism-coupling setup into this low-cost compact plasmonic platform would have a far-reaching impact on point-of-care diagnostic tools and also lead to advances in high-throughput sensing applications in proteomics, immunology, drug discovery, and fundamental cell biology research.
Carbon Nanotube Based Chemical Sensors for Space and Terrestrial Applications
NASA Technical Reports Server (NTRS)
Li, Jing; Lu, Yijiang
2009-01-01
A nanosensor technology has been developed using nanostructures, such as single walled carbon nanotubes (SWNTs), on a pair of interdigitated electrodes (IDE) processed with a silicon-based microfabrication and micromachining technique. The IDE fingers were fabricated using photolithography and thin film metallization techniques. Both in-situ growth of nanostructure materials and casting of the nanostructure dispersions were used to make chemical sensing devices. These sensors have been exposed to nitrogen dioxide, acetone, benzene, nitrotoluene, chlorine, and ammonia in the concentration range of ppm to ppb at room temperature. The electronic molecular sensing of carbon nanotubes in our sensor platform can be understood by intra- and inter-tube electron modulation in terms of charge transfer mechanisms. As a result of the charge transfer, the conductance of p-type or hole-richer SWNTs in air will change. Due to the large surface area, low surface energy barrier and high thermal and mechanical stability, nanostructured chemical sensors potentially can offer higher sensitivity, lower power consumption and better robustness than the state-of-the-art systems, which make them more attractive for defense and space applications. Combined with MEMS technology, light weight and compact size sensors can be made in wafer scale with low cost. Additionally, a wireless capability of such a sensor chip can be used for networked mobile and fixed-site detection and warning systems for military bases, facilities and battlefield areas.
Low cost sensors for PM and related air pollutants in the US and India
Emerging air quality sensors have a variety of possible applications. If accurate and reliable, they have a number of benefits over conventional monitors. They are low-cost, lightweight, and have low power consumption. Because of their low cost, a dense array of sensors instal...
Low-cost thermo-electric infrared FPAs and their automotive applications
NASA Astrophysics Data System (ADS)
Hirota, Masaki; Ohta, Yoshimi; Fukuyama, Yasuhiro
2008-04-01
This paper describes three low-cost infrared focal plane arrays (FPAs) having a 1,536, 2,304, and 10,800 elements and experimental vehicle systems. They have a low-cost potential because each element consists of p-n polysilicon thermocouples, which allows the use of low-cost ultra-fine microfabrication technology commonly employed in the conventional semiconductor manufacturing processes. To increase the responsivity of FPA, we have developed a precisely patterned Au-black absorber that has high infrared absorptivity of more than 90%. The FPA having a 2,304 elements achieved high resposivity of 4,300 V/W. In order to reduce package cost, we developed a vacuum-sealed package integrated with a molded ZnS lens. The camera aiming the temperature measurement of a passenger cabin is compact and light weight devices that measures 45 x 45 x 30 mm and weighs 190 g. The camera achieves a noise equivalent temperature deviation (NETD) of less than 0.7°C from 0 to 40°C. In this paper, we also present a several experimental systems that use infrared cameras. One experimental system is a blind spot pedestrian warning system that employs four infrared cameras. It can detect the infrared radiation emitted from a human body and alerts the driver when a pedestrian is in a blind spot. The system can also prevent the vehicle from moving in the direction of the pedestrian. Another system uses a visible-light camera and infrared sensors to detect the presence of a pedestrian in a rear blind spot and alerts the driver. The third system is a new type of human-machine interface system that enables the driver to control the car's audio system without letting go of the steering wheel. Uncooled infrared cameras are still costly, which limits their automotive use to high-end luxury cars at present. To promote widespread use of IR imaging sensors on vehicles, we need to reduce their cost further.
End-user perspective of low-cost sensors for outdoor air pollution monitoring.
Rai, Aakash C; Kumar, Prashant; Pilla, Francesco; Skouloudis, Andreas N; Di Sabatino, Silvana; Ratti, Carlo; Yasar, Ansar; Rickerby, David
2017-12-31
Low-cost sensor technology can potentially revolutionise the area of air pollution monitoring by providing high-density spatiotemporal pollution data. Such data can be utilised for supplementing traditional pollution monitoring, improving exposure estimates, and raising community awareness about air pollution. However, data quality remains a major concern that hinders the widespread adoption of low-cost sensor technology. Unreliable data may mislead unsuspecting users and potentially lead to alarming consequences such as reporting acceptable air pollutant levels when they are above the limits deemed safe for human health. This article provides scientific guidance to the end-users for effectively deploying low-cost sensors for monitoring air pollution and people's exposure, while ensuring reasonable data quality. We review the performance characteristics of several low-cost particle and gas monitoring sensors and provide recommendations to end-users for making proper sensor selection by summarizing the capabilities and limitations of such sensors. The challenges, best practices, and future outlook for effectively deploying low-cost sensors, and maintaining data quality are also discussed. For data quality assurance, a two-stage sensor calibration process is recommended, which includes laboratory calibration under controlled conditions by the manufacturer supplemented with routine calibration checks performed by the end-user under final deployment conditions. For large sensor networks where routine calibration checks are impractical, statistical techniques for data quality assurance should be utilised. Further advancements and adoption of sophisticated mathematical and statistical techniques for sensor calibration, fault detection, and data quality assurance can indeed help to realise the promised benefits of a low-cost air pollution sensor network. Copyright © 2017 Elsevier B.V. All rights reserved.
Ultra-low power operation of self-heated, suspended carbon nanotube gas sensors
NASA Astrophysics Data System (ADS)
Chikkadi, Kiran; Muoth, Matthias; Maiwald, Verena; Roman, Cosmin; Hierold, Christofer
2013-11-01
We present a suspended carbon nanotube gas sensor that senses NO2 at ambient temperature and recovers from gas exposure at an extremely low power of 2.9 μW by exploiting the self-heating effect for accelerated gas desorption. The recovery time of 10 min is two orders of magnitude faster than non-heated recovery at ambient temperature. This overcomes an important bottleneck for the practical application of carbon nanotube gas sensors. Furthermore, the method is easy to implement in sensor systems and requires no additional components, paving the way for ultra-low power, compact, and highly sensitive gas sensors.
Fast and compact internal scanning CMOS-based hyperspectral camera: the Snapscan
NASA Astrophysics Data System (ADS)
Pichette, Julien; Charle, Wouter; Lambrechts, Andy
2017-02-01
Imec has developed a process for the monolithic integration of optical filters on top of CMOS image sensors, leading to compact, cost-efficient and faster hyperspectral cameras. Linescan cameras are typically used in remote sensing or for conveyor belt applications. Translation of the target is not always possible for large objects or in many medical applications. Therefore, we introduce a novel camera, the Snapscan (patent pending), exploiting internal movement of a linescan sensor enabling fast and convenient acquisition of high-resolution hyperspectral cubes (up to 2048x3652x150 in spectral range 475-925 nm). The Snapscan combines the spectral and spatial resolutions of a linescan system with the convenience of a snapshot camera.
NASA Astrophysics Data System (ADS)
Lee, Seung Yup; Na, Kyounghwan; Pakela, Julia M.; Scheiman, James M.; Yoon, Euisik; Mycek, Mary-Ann
2017-02-01
We present the design, development, and bench-top verification of an innovative compact clinical system including a miniaturized handheld optoelectronic sensor. The integrated sensor was microfabricated with die-level light-emitting diodes and photodiodes and fits into a 19G hollow needle (internal diameter: 0.75 mm) for optical sensing applications in solid tissues. Bench-top studies on tissue-simulating phantoms have verified system performance relative to a fiberoptic based tissue spectroscopy system. With dramatically reduced system size and cost, the technology affords spatially configurable designs for optoelectronic light sources and detectors, thereby enabling customized sensing configurations that would be impossible to achieve with needle-based fiber-optic probes.
Mertens, Jan E.J.; Roie, Martijn Van; Merckx, Jonas; Dekoninck, Wouter
2017-01-01
Abstract Digitization of specimen collections has become a key priority of many natural history museums. The camera systems built for this purpose are expensive, providing a barrier in institutes with limited funding, and therefore hampering progress. An assessment is made on whether a low cost compact camera with image stacking functionality can help expedite the digitization process in large museums or provide smaller institutes and amateur entomologists with the means to digitize their collections. Images of a professional setup were compared with the Olympus Stylus TG-4 Tough, a low-cost compact camera with internal focus stacking functions. Parameters considered include image quality, digitization speed, price, and ease-of-use. The compact camera’s image quality, although inferior to the professional setup, is exceptional considering its fourfold lower price point. Producing the image slices in the compact camera is a matter of seconds and when optimal image quality is less of a priority, the internal stacking function omits the need for dedicated stacking software altogether, further decreasing the cost and speeding up the process. In general, it is found that, aware of its limitations, this compact camera is capable of digitizing entomological collections with sufficient quality. As technology advances, more institutes and amateur entomologists will be able to easily and affordably catalogue their specimens. PMID:29134038
Optical connections on flexible substrates
NASA Astrophysics Data System (ADS)
Bosman, Erwin; Geerinck, Peter; Christiaens, Wim; Van Steenberge, Geert; Vanfleteren, Jan; Van Daele, Peter
2006-04-01
Optical interconnections integrated on a flexible substrate combine the advantages of optical data transmissions (high bandwidth, no electromagnetic disturbance and low power consumption) and those of flexible substrates (compact, ease of assembly...). Especially the flexible character of the substrates can significantly lower the assembly cost and leads to more compact modules. Especially in automotive-, avionic-, biomedical and sensing applications there is a great potential for these flexible optical interconnections because of the increasing data-rates, increasing use of optical sensors and requirement for smaller size and weight. The research concentrates on the integration of commercially available polymer optical layers (Truemode Backplane TM Polymer, Ormocer®) on a flexible Polyimide film, the fabrication of waveguides and out-of plane deflecting 45° mirrors, the characterization of the optical losses due to the bending of the substrate, and the fabrication of a proof-of-principal demonstrator. The resulting optical structures should be compatible with the standard fabrication of flexible printed circuit boards.
Silicon wafer temperature monitoring using all-fiber laser ultrasonics
NASA Astrophysics Data System (ADS)
Alcoz, Jorge J.; Duffer, Charles E.
1998-03-01
Laser-ultrasonics is a very attractive technique for in-line process control in the semiconductor industry as it is compatible with the clean room environment and offers the capability to inspect parts at high-temperature. We describe measurements of the velocity of laser-generated Lamb waves in silicon wafers as a function of temperature using fiber- optic laser delivery and all-fiber interferometric sensing. Fundamental anti-symmetric Lamb-wave modes were generated in 5 inches < 111 > silicon wafers using a Nd:YAG laser coupled to a large-core multimode fiber. Generation was also performed using an array of sources created with a diffraction grating. For detection a compact fiber-optic sensor was used which is well suited for industrial environments as it is compact, rugged, stable, and low-cost. The wafers were heated up to 1000 degrees C and the temperature correlated with ultrasonic velocity measurements.
Wu, Jing; Liu, Xianhu; Wang, Lili; Dong, Lijun; Pu, Qiaosheng
2012-01-21
An economical fluorescence detector was developed with an LED as the exciting source and a low-cost avalanche photodiode (APD) module as a photon sensor. The detector was arranged in an epifluorescence configuration using a microscope objective (20× or 40×) and a dichroic mirror. The low-cost APD was biased by a direct current (DC) high voltage power supply at 121 V, which is much lower than that normally used for a PMT. Both DC and square wave (SW) supplies were used to power the LED and different data treatment protocols, such as simple average for DC mode, software based lock-in amplification and time specific average for SW mode, were tested to maximize the signal-to-noise ratio. Using an LED at a DC mode with simple data averaging, a limit of detection of 0.2 nmol L(-1) for sodium fluorescein was attained, which is among the lowest ever achieved with an LED as an excitation source. The detector was successfully used in both capillary and chip electrophoresis. The most significant advantages of the detector are the compact size and low cost of its parts. The aim of the work is to prove that widely available, low-cost components for civilian use can be successfully used for miniaturized analytical devices.
Open Source Radiation Hardened by Design Technology
NASA Technical Reports Server (NTRS)
Shuler, Robert
2016-01-01
The proposed technology allows use of the latest microcircuit technology with lowest power and fastest speed, with minimal delay and engineering costs, through new Radiation Hardened by Design (RHBD) techniques that do not require extensive process characterization, technique evaluation and re-design at each Moore's Law generation. The separation of critical node groups is explicitly parameterized so it can be increased as microcircuit technologies shrink. The technology will be open access to radiation tolerant circuit vendors. INNOVATION: This technology would enhance computation intensive applications such as autonomy, robotics, advanced sensor and tracking processes, as well as low power applications such as wireless sensor networks. OUTCOME / RESULTS: 1) Simulation analysis indicates feasibility. 2)Compact voting latch 65 nanometer test chip designed and submitted for fabrication -7/2016. INFUSION FOR SPACE / EARTH: This technology may be used in any digital integrated circuit in which a high level of resistance to Single Event Upsets is desired, and has the greatest benefit outside low earth orbit where cosmic rays are numerous.
Martín, Angel; Padín, Jorge; Anquela, Ana Belén; Sánchez, Juán; Belda, Santiago
2009-01-01
Magnetic data consists of a sequence of collected points with spatial coordinates and magnetic information. The spatial location of these points needs to be as exact as possible in order to develop a precise interpretation of magnetic anomalies. GPS is a valuable tool for accomplishing this objective, especially if the RTK approach is used. In this paper the VRS (Virtual Reference Station) technique is introduced as a new approach for real-time positioning of magnetic sensors. The main advantages of the VRS approach are, firstly, that only a single GPS receiver is needed (no base station is necessary), reducing field work and equipment costs. Secondly, VRS can operate at distances separated 50–70 km from the reference stations without degrading accuracy. A compact integration of a GSM-19 magnetometer sensor with a geodetic GPS antenna is presented; this integration does not diminish the operational flexibility of the original magnetometer and can work with the VRS approach. The coupled devices were tested in marshlands around Gandia, a city located approximately 100 km South of Valencia (Spain), thought to be the site of a Roman cemetery. The results obtained show adequate geometry and high-precision positioning for the structures to be studied (a comparison with the original low precision GPS of the magnetometer is presented). Finally, the results of the magnetic survey are of great interest for archaeological purposes. PMID:22574055
Tisch, Ulrike; Haick, Hossam
2014-06-01
Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.
Range-Gated Metrology: An Ultra-Compact Sensor for Dimensional Stabilization
NASA Technical Reports Server (NTRS)
Lay, Oliver P.; Dubovitsky, Serge; Shaddock, Daniel A.; Ware, Brent; Woodruff, Christopher S.
2008-01-01
Point-to-point laser metrology systems can be used to stabilize large structures at the nanometer levels required for precision optical systems. Existing sensors are large and intrusive, however, with optical heads that consist of several optical elements and require multiple optical fiber connections. The use of point-to-point laser metrology has therefore been limited to applications where only a few gauges are needed and there is sufficient space to accommodate them. Range-Gated Metrology is a signal processing technique that preserves nanometer-level or better performance while enabling: (1) a greatly simplified optical head - a single fiber optic collimator - that can be made very compact, and (2) a single optical fiber connection that is readily multiplexed. This combination of features means that it will be straightforward and cost-effective to embed tens or hundreds of compact metrology gauges to stabilize a large structure. In this paper we describe the concept behind Range-Gated Metrology, demonstrate the performance in a laboratory environment, and give examples of how such a sensor system might be deployed.
Low-Cost GRIN-Lens-Based Nephelometric Turbidity Sensing in the Range of 0.1-1000 NTU.
Metzger, Michael; Konrad, Alexander; Blendinger, Felix; Modler, Andreas; Meixner, Alfred J; Bucher, Volker; Brecht, Marc
2018-04-06
Turbidity sensing is very common in the control of drinking water. Furthermore, turbidity measurements are applied in the chemical (e.g., process monitoring), pharmaceutical (e.g., drug discovery), and food industries (e.g., the filtration of wine and beer). The most common measurement technique is nephelometric turbidimetry. A nephelometer is a device for measuring the amount of scattered light of suspended particles in a liquid by using a light source and a light detector orientated in 90° to each other. Commercially available nephelometers cost usually-depending on the measurable range, reliability, and precision-thousands of euros. In contrast, our new developed GRIN-lens-based nephelometer, called GRINephy, combines low costs with excellent reproducibility and precision, even at very low turbidity levels, which is achieved by its ability to rotate the sample. Thereby, many cuvette positions can be measured, which results in a more precise average value for the turbidity calculated by an algorithm, which also eliminates errors caused by scratches and contaminations on the cuvettes. With our compact and cheap Arduino-based sensor, we are able to measure in the range of 0.1-1000 NTU and confirm the ISO 7027-1:2016 for low turbidity values.
NASA Astrophysics Data System (ADS)
de Goeij, B. T. G.; Otter, G. C. J.; van Wakeren, J. M. O.; Veefkind, J. P.; Vlemmix, T.; Ge, X.; Levelt, P. F.; Dirks, B. P. F.; Toet, P. M.; van der Wal, L. F.; Jansen, R.
2017-09-01
In recent years TNO has investigated and developed different innovative opto-mechanical designs to realize advanced spectrometers for space applications in a more compact and cost-effective manner. This offers multiple advantages: a compact instrument can be flown on a much smaller platform or as add-on on a larger platform; a low-cost instrument opens up the possibility to fly multiple instruments in a satellite constellation, improving both global coverage and temporal sampling (e.g. multiple overpasses per day to study diurnal processes); in this way a constellation of low-cost instruments may provide added value to the larger scientific and operational satellite missions (e.g. the Copernicus Sentinel missions); a small, lightweight spectrometer can easily be mounted on a small aircraft or high-altitude UAV (offering high spatial resolution).
Compact and high resolution virtual mouse using lens array and light sensor
NASA Astrophysics Data System (ADS)
Qin, Zong; Chang, Yu-Cheng; Su, Yu-Jie; Huang, Yi-Pai; Shieh, Han-Ping David
2016-06-01
Virtual mouse based on IR source, lens array and light sensor was designed and implemented. Optical architecture including lens amount, lens pitch, baseline length, sensor length, lens-sensor gap, focal length etc. was carefully designed to achieve low detective error, high resolution, and simultaneously, compact system volume. System volume is 3.1mm (thickness) × 4.5mm (length) × 2, which is much smaller than that of camera-based device. Relative detective error of 0.41mm and minimum resolution of 26ppi were verified in experiments, so that it can replace conventional touchpad/touchscreen. If system thickness is eased to 20mm, resolution higher than 200ppi can be achieved to replace real mouse.
A novel capacitive absolute positioning sensor based on time grating with nanometer resolution
NASA Astrophysics Data System (ADS)
Pu, Hongji; Liu, Hongzhong; Liu, Xiaokang; Peng, Kai; Yu, Zhicheng
2018-05-01
The present work proposes a novel capacitive absolute positioning sensor based on time grating. The sensor includes a fine incremental-displacement measurement component combined with a coarse absolute-position measurement component to obtain high-resolution absolute positioning measurements. A single row type sensor was proposed to achieve fine displacement measurement, which combines the two electrode rows of a previously proposed double-row type capacitive displacement sensor based on time grating into a single row. To achieve absolute positioning measurement, the coarse measurement component is designed as a single-row type displacement sensor employing a single spatial period over the entire measurement range. In addition, this component employs a rectangular induction electrode and four groups of orthogonal discrete excitation electrodes with half-sinusoidal envelope shapes, which were formed by alternately extending the rectangular electrodes of the fine measurement component. The fine and coarse measurement components are tightly integrated to form a compact absolute positioning sensor. A prototype sensor was manufactured using printed circuit board technology for testing and optimization of the design in conjunction with simulations. Experimental results show that the prototype sensor achieves a ±300 nm measurement accuracy with a 1 nm resolution over a displacement range of 200 mm when employing error compensation. The proposed sensor is an excellent alternative to presently available long-range absolute nanometrology sensors owing to its low cost, simple structure, and ease of manufacturing.
Sukič, Primož; Štumberger, Gorazd
2017-05-13
Clouds moving at a high speed in front of the Sun can cause step changes in the output power of photovoltaic (PV) power plants, which can lead to voltage fluctuations and stability problems in the connected electricity networks. These effects can be reduced effectively by proper short-term cloud passing forecasting and suitable PV power plant output power control. This paper proposes a low-cost Internet of Things (IoT)-based solution for intra-minute cloud passing forecasting. The hardware consists of a Raspberry PI Model B 3 with a WiFi connection and an OmniVision OV5647 sensor with a mounted wide-angle lens, a circular polarizing (CPL) filter and a natural density (ND) filter. The completely new algorithm for cloud passing forecasting uses the green and blue colors in the photo to determine the position of the Sun, to recognize the clouds, and to predict their movement. The image processing is performed in several stages, considering selectively only a small part of the photo relevant to the movement of the clouds in the vicinity of the Sun in the next minute. The proposed algorithm is compact, fast and suitable for implementation on low cost processors with low computation power. The speed of the cloud parts closest to the Sun is used to predict when the clouds will cover the Sun. WiFi communication is used to transmit this data to the PV power plant control system in order to decrease the output power slowly and smoothly.
Mobile phone based mini-spectrometer for rapid screening of skin cancer
NASA Astrophysics Data System (ADS)
Das, Anshuman; Swedish, Tristan; Wahi, Akshat; Moufarrej, Mira; Noland, Marie; Gurry, Thomas; Aranda-Michel, Edgar; Aksel, Deniz; Wagh, Sneha; Sadashivaiah, Vijay; Zhang, Xu; Raskar, Ramesh
2015-06-01
We demonstrate a highly sensitive mobile phone based spectrometer that has potential to detect cancerous skin lesions in a rapid, non-invasive manner. Earlier reports of low cost spectrometers utilize the camera of the mobile phone to image the field after moving through a diffraction grating. These approaches are inherently limited by the closed nature of mobile phone image sensors and built in optical elements. The system presented uses a novel integrated grating and sensor that is compact, accurate and calibrated. Resolutions of about 10 nm can be achieved. Additionally, UV and visible LED excitation sources are built into the device. Data collection and analysis is simplified using the wireless interfaces and logical control on the smart phone. Furthermore, by utilizing an external sensor, the mobile phone camera can be used in conjunction with spectral measurements. We are exploring ways to use this device to measure endogenous fluorescence of skin in order to distinguish cancerous from non-cancerous lesions with a mobile phone based dermatoscope.
A Low-Cost and Portable Dual-Channel Fiber Optic Surface Plasmon Resonance System.
Liu, Qiang; Liu, Yun; Chen, Shimeng; Wang, Fang; Peng, Wei
2017-12-04
A miniaturization and integration dual-channel fiber optic surface plasmon resonance (SPR) system was proposed and demonstrated in this paper. We used a yellow light-emitting diode (LED, peak wavelength 595 nm) and built-in web camera as a light source and detector, respectively. Except for the detection channel, one of the sensors was used as a reference channel to compensate nonspecific binding and physical absorption. We packaged the LED and surface plasmon resonance (SPR) sensors together, which are flexible enough to be applied to mobile devices as a compact and portable system. Experimental results show that the normalized intensity shift and refractive index (RI) of the sample have a good linear relationship in the RI range from 1.328 to 1.348. We used this sensor to monitor the reversible, specific interaction between lectin concanavalin A (Con A) and glycoprotein ribonuclease B (RNase B), which demonstrate its capabilities of specific identification and biochemical samples concentration detection. This sensor system has potential applications in various fields, such as medical diagnosis, public health, food safety, and environment monitoring.
Compact, low profile antennas for MSAT and mini-M and Std-M land mobile satellite communications
NASA Technical Reports Server (NTRS)
Strickland, P. C.
1995-01-01
CAL Corporation has developed a new class of low profile radiating elements for use in planar phased array antennas. These new elements have been used in the design of a low cost, compact, low profile antenna unit for MSAT and INMARSAT Mini-M land mobile satellite communications. The antenna unit which measures roughly 32 cm in diameter by 5 cm deep incorporates a compact LNA and diplexer unit as well as a complete, low cost, beam steering system. CAL has also developed a low profile antenna unit for INMARSAT-M land mobile satellite communications. A number of these units, which utilize a microstrip patch array design, were put into service in 1994.
A TinyOS-enabled MICA2-based wireless neural interface.
Farshchi, Shahin; Nuyujukian, Paul H; Pesterev, Aleksey; Mody, Istvan; Judy, Jack W
2006-07-01
Existing approaches used to develop compact low-power multichannel wireless neural recording systems range from creating custom-integrated circuits to assembling commercial-off-the-shelf (COTS) PC-based components. Custom-integrated-circuit designs yield extremely compact and low-power devices at the expense of high development and upgrade costs and turn-around times, while assembling COTS-PC-technology yields high performance at the expense of large system size and increased power consumption. To achieve a balance between implementing an ultra-compact custom-fabricated neural transceiver and assembling COTS-PC-technology, an overlay of a neural interface upon the TinyOS-based MICA2 platform is described. The system amplifies, digitally encodes, and transmits neural signals real-time at a rate of 9.6 kbps, while consuming less than 66 mW of power. The neural signals are received and forwarded to a client PC over a serial connection. This data rate can be divided for recording on up to 6 channels, with a resolution of 8 bits/sample. This work demonstrates the strengths and limitations of the TinyOS-based sensor technology as a foundation for chronic remote biological monitoring applications and, thus, provides an opportunity to create a system that can leverage from the frequent networking and communications advancements being made by the global TinyOS-development community.
SenseCube—a novel inexpensive wireless multisensor for physics lab experimentations
NASA Astrophysics Data System (ADS)
Mehta, Vedant; Lane, Charles D.
2018-07-01
SenseCube is a multisensor capable of measuring many different real-time events and changes in environment. Most conventional sensors used in introductory-physics labs use their own software and have wires that must be attached to a computer or an alternate device to analyze the data. This makes the standard sensors time consuming, tedious, and space-constricted. SenseCube was developed to overcome these limitations. This research was focused on developing a device that is all-encompassing, cost-effective, wireless, and compact, yet can perform the same tasks as the multiple standard sensors normally used in physics labs. It measures more than twenty distinct types of real-time events and transfers the data via Bluetooth. Both Windows and Mac software were developed so that the data from this device can be retrieved and/or saved on either platform. This paper describes the sensor itself, its development, its capabilities, and its cost comparison with standard sensors.
Development of a novel fiber-optic sensor to measure radon in the deep ocean
NASA Astrophysics Data System (ADS)
Monteiro, Catarina; Guimarães, Diana; Jorge, Pedro; Barbosa, Susana
2017-04-01
The radon concentration in the deep ocean has gained increasing interest in the last decades. The underwater monitoring of this natural radioactive gas can give important information about submarine groundwater discharges, groundwater migration and contamination. Radon concentration has also been studied as a possible indicator of earthquake events which can have devastating consequences when the epicenter is located at the sea. In contrast with radon monitoring studies in caves, mines, and underground soil, there is an utter lack of information about radon in deep-sea. These measurements are particularly difficult to attain due to the challenges that marine-like environments post to electronic sensing devices and their maintenance over time. Gamma rays emitted by radon's progeny can be easily detected when interacting with a scintillator material. Recently, optical fiber doped with scintillating material has emerged has an alternative for gamma ray detection. The lightweight, low transmission loss, immunity to electromagnetic interference and the cost effectiveness makes optical fiber a compelling solution for radiation detection when compared to conventional sensors. In this work a compact all-fiber optical sensor is developed for continuous gamma ray detection in the deep sea. This sensor is composed by a scintillating optical fiber coupled to a polymeric optical fiber that allows the detection of low levels of radiation.
Design of a compact low-power human-computer interaction equipment for hand motion
NASA Astrophysics Data System (ADS)
Wu, Xianwei; Jin, Wenguang
2017-01-01
Human-Computer Interaction (HCI) raises demand of convenience, endurance, responsiveness and naturalness. This paper describes a design of a compact wearable low-power HCI equipment applied to gesture recognition. System combines multi-mode sense signals: the vision sense signal and the motion sense signal, and the equipment is equipped with the depth camera and the motion sensor. The dimension (40 mm × 30 mm) and structure is compact and portable after tight integration. System is built on a module layered framework, which contributes to real-time collection (60 fps), process and transmission via synchronous confusion with asynchronous concurrent collection and wireless Blue 4.0 transmission. To minimize equipment's energy consumption, system makes use of low-power components, managing peripheral state dynamically, switching into idle mode intelligently, pulse-width modulation (PWM) of the NIR LEDs of the depth camera and algorithm optimization by the motion sensor. To test this equipment's function and performance, a gesture recognition algorithm is applied to system. As the result presents, general energy consumption could be as low as 0.5 W.
Chowdhury, Amor; Sarjaš, Andrej
2016-01-01
The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation. PMID:27649197
Chowdhury, Amor; Sarjaš, Andrej
2016-09-15
The presented paper describes accurate distance measurement for a field-sensed magnetic suspension system. The proximity measurement is based on a Hall effect sensor. The proximity sensor is installed directly on the lower surface of the electro-magnet, which means that it is very sensitive to external magnetic influences and disturbances. External disturbances interfere with the information signal and reduce the usability and reliability of the proximity measurements and, consequently, the whole application operation. A sensor fusion algorithm is deployed for the aforementioned reasons. The sensor fusion algorithm is based on the Unscented Kalman Filter, where a nonlinear dynamic model was derived with the Finite Element Modelling approach. The advantage of such modelling is a more accurate dynamic model parameter estimation, especially in the case when the real structure, materials and dimensions of the real-time application are known. The novelty of the paper is the design of a compact electro-magnetic actuator with a built-in low cost proximity sensor for accurate proximity measurement of the magnetic object. The paper successively presents a modelling procedure with the finite element method, design and parameter settings of a sensor fusion algorithm with Unscented Kalman Filter and, finally, the implementation procedure and results of real-time operation.
In-Line Fiber Optic Interferometric Sensors in Single-Mode Fibers
Zhu, Tao; Wu, Di; Liu, Min; Duan, De-Wen
2012-01-01
In-line fiber optic interferometers have attracted intensive attention for their potential sensing applications in refractive index, temperature, pressure and strain measurement, etc. Typical in-line fiber-optic interferometers are of two types: Fabry-Perot interferometers and core-cladding-mode interferometers. It's known that the in-line fiber optic interferometers based on single-mode fibers can exhibit compact structures, easy fabrication and low cost. In this paper, we review two kinds of typical in-line fiber optic interferometers formed in single-mode fibers fabricated with different post-processing techniques. Also, some recently reported specific technologies for fabricating such fiber optic interferometers are presented. PMID:23112608
Metal Oxide Nanostructures and Their Gas Sensing Properties: A Review
Sun, Yu-Feng; Liu, Shao-Bo; Meng, Fan-Li; Liu, Jin-Yun; Jin, Zhen; Kong, Ling-Tao; Liu, Jin-Huai
2012-01-01
Metal oxide gas sensors are predominant solid-state gas detecting devices for domestic, commercial and industrial applications, which have many advantages such as low cost, easy production, and compact size. However, the performance of such sensors is significantly influenced by the morphology and structure of sensing materials, resulting in a great obstacle for gas sensors based on bulk materials or dense films to achieve highly-sensitive properties. Lots of metal oxide nanostructures have been developed to improve the gas sensing properties such as sensitivity, selectivity, response speed, and so on. Here, we provide a brief overview of metal oxide nanostructures and their gas sensing properties from the aspects of particle size, morphology and doping. When the particle size of metal oxide is close to or less than double thickness of the space-charge layer, the sensitivity of the sensor will increase remarkably, which would be called “small size effect”, yet small size of metal oxide nanoparticles will be compactly sintered together during the film coating process which is disadvantage for gas diffusion in them. In view of those reasons, nanostructures with many kinds of shapes such as porous nanotubes, porous nanospheres and so on have been investigated, that not only possessed large surface area and relatively mass reactive sites, but also formed relatively loose film structures which is an advantage for gas diffusion. Besides, doping is also an effective method to decrease particle size and improve gas sensing properties. Therefore, the gas sensing properties of metal oxide nanostructures assembled by nanoparticles are reviewed in this article. The effect of doping is also summarized and finally the perspectives of metal oxide gas sensor are given. PMID:22736968
Metal oxide nanostructures and their gas sensing properties: a review.
Sun, Yu-Feng; Liu, Shao-Bo; Meng, Fan-Li; Liu, Jin-Yun; Jin, Zhen; Kong, Ling-Tao; Liu, Jin-Huai
2012-01-01
Metal oxide gas sensors are predominant solid-state gas detecting devices for domestic, commercial and industrial applications, which have many advantages such as low cost, easy production, and compact size. However, the performance of such sensors is significantly influenced by the morphology and structure of sensing materials, resulting in a great obstacle for gas sensors based on bulk materials or dense films to achieve highly-sensitive properties. Lots of metal oxide nanostructures have been developed to improve the gas sensing properties such as sensitivity, selectivity, response speed, and so on. Here, we provide a brief overview of metal oxide nanostructures and their gas sensing properties from the aspects of particle size, morphology and doping. When the particle size of metal oxide is close to or less than double thickness of the space-charge layer, the sensitivity of the sensor will increase remarkably, which would be called "small size effect", yet small size of metal oxide nanoparticles will be compactly sintered together during the film coating process which is disadvantage for gas diffusion in them. In view of those reasons, nanostructures with many kinds of shapes such as porous nanotubes, porous nanospheres and so on have been investigated, that not only possessed large surface area and relatively mass reactive sites, but also formed relatively loose film structures which is an advantage for gas diffusion. Besides, doping is also an effective method to decrease particle size and improve gas sensing properties. Therefore, the gas sensing properties of metal oxide nanostructures assembled by nanoparticles are reviewed in this article. The effect of doping is also summarized and finally the perspectives of metal oxide gas sensor are given.
A Silicon Disk with Sandwiched Piezoelectric Springs for Ultra-low Frequency Energy Harvesting
NASA Astrophysics Data System (ADS)
Lu, J.; Zhang, L.; Yamashita, T.; Takei, R.; Makimoto, N.; Kobayashi, T.
2015-12-01
Exploiting the sporadic availability of energy by energy harvesting devices is an attractive solution to power wireless sensor nodes and many other distributed modules for much longer operation duration and much lower maintenance cost after they are deployed. MEMS energy harvesting devices exhibit unique advantageous of super-compact size, mass productivity, and easy-integration with sensors, actuators and other integrated circuits. However, MEMS vibration energy harvesting devices are rather difficult to be used practically due to their poor response to most of the ambient vibrations at ultra-low frequency range. In this paper, a micromachined silicon disk with sandwiched piezoelectric springs was successfully developed with resonant frequency of 15.36∼42.42 Hz and quality factor of 39∼55 for energy harvesting. Footprint size of the device was 6 mm × 6 mm, which is less than half of the piezoelectric cantilevers, while the device can scavenge reasonably high power of 0.57 μW at the acceleration of 0.1 g. The evaluation results also suggested that the device was quite sensitive as a sensor for selective monitoring of vibrations at a certain frequency.
Miniature star tracker for small remote sensing satellites
NASA Astrophysics Data System (ADS)
Cassidy, Lawrence W.; Schlom, Leslie
1995-01-01
Designers of future remote sensing spacecraft, including platforms for Mission to Planet Earth and small satellites, will be driven to provide spacecraft designs that maximize data return and minimize hardware and operating costs. The attitude determination subsystems of these spacecraft must likewise provide maximum capability and versatility at an affordable price. Hughes Danbury Optical Systems (HDOS) has developed the Model HD-1003 Miniature Star Tracker which combines high accuracy, high reliability and growth margin for `all-stellar' capability in a compact, radiation tolerant design that meets these future spacecraft needs and whose cost is competitive with horizon sensors and digital fine sum sensors. Begun in 1991, our HD-1003 development program has now entered the hardware qualification phase. This paper acquaints spacecraft designers with the design and performance capabilities of the HD- 1003 tracker. We highlight the tracker's unique features which include: (1) Very small size (165 cu. in.). (2) Low weight (7 lbs). (3) Multi-star tracking (6 stars simultaneously). (4) Eighteen arc-sec (3-sigma) accuracy. (5) Growth margin for `all-stellar' attitude reference.
Geng, Xuhui; Shi, Meng; Ning, Haijing; Feng, Chunbo; Guan, Yafeng
2018-05-15
A compact and low-cost laser induced fluorescence (LIF) detector based on confocal structure for capillary flow systems was developed and applied for analysis of Her2 protein on single Hela cells. A low-power and low-cost 450 nm laser diode (LD) instead of a high quality laser was used as excitation light source. A compact optical design together with shortened optical path length improved the optical efficiency and detection sensitivity. A superior silicon based photodetector assembly was used for fluorescence detection instead of a photomultiplier (PMT). The limit of detection (LOD) for fluorescein sodium was 3 × 10 -12 M or 165 fluorescein molecules in detection volume measured on a homemade capillary electroosmotic driven (EOD)-LIF system, which was similar to commercial LIFs. Compared to commercial LIFs, the whole volume of our LIF was reduced to 1/2-1/3, and the cost was less than 1/3 of them. Copyright © 2018 Elsevier B.V. All rights reserved.
Development of a Low Cost, Compact, Spectrophotometric pH Sensor
NASA Astrophysics Data System (ADS)
Spaulding, R. S.; Darlington, R. C.; Beck, J. C.; DeGrandpre, M. D.
2016-02-01
Understanding the ecological impacts of oceanic CO2 uptake in the post-industrial world requires high spatial and temporal resolution measurements of inorganic carbon. Most researchers aim for measuring two of the four inorganic carbon parameters (partial pressure of CO2, total alkalinity, total dissolve inorganic carbon, and pH), in order to fully characterize the carbonate system. While this is desirable in many circumstances, in some cases it may be possible to fully characterize the system using pH and salinity, or even to use pH alone as a proxy to the health of calcifying marine organisms. The development of relatively inexpensive spectrophotometric pH sensors compatible with Lagrangian drifters would greatly improve the ability of researchers to characterize the changing oceanic carbonate system. We have designed and tested a novel, miniaturized, submersible, autonomous opto-fluidic device that can be manufactured at a relatively low cost. The flexible design can be deployed independent of or in tandem with GDP style drifters and will enable spectrophotometric pH technology on a host of drifting platforms and buoys. This device uses a dual wavelength light emitting diode (LED) light source, low volume mixer, and an optical flow-cell mounted to the electronic controller board. Laboratory testing shows that this device measures pH with similar accuracy and precision to other spectrophotometric methods such as the SAMI-pH.
Optical design of a compact near-infrared multispecies gas sensor
NASA Astrophysics Data System (ADS)
Larson, Joshua; Toor, Fatima
In this work we present the design of a compact and cost effective near infrared (NIR) gas sensor system that can detect nitrous oxide (NOx) , ammonia (NH3) , and methane (CH4) simultaneously. These three gases were chosen as they are environmental pollutants and their monitoring is especially important in agricultural states like Iowa. As a first step in our design process, we have developed a Matlab model based on Beer-Lambert's law to generate sample sensor data for each of the gases at different concentrations. The data measured from the sensor system will be as a function of time instead of wavelength, so we performed Fourier Transform analysis on the sensor data to convert it to voltage versus time. The simulated sensor data will enable to design software algorithms to separate the absorption signals for each of the three gases. As a second step, we have developed a lab-based sensor system comprising of three components: (i) a NIR lead sulfide (PbS) photodiode, (ii) an LED that emits 1900 nm to 2600 nm, and (iii) an optical cavity where the gases are introduced. We are designing the optical cavity using ray optics COMSOL finite element method simulator using the principles of a compact chaotic cavity that will allow the LED light to have a path length of greater than 100 m within the cavity, enabling high sensitivity gas detection. Our end goal is to have an autonomous drone mounted device that is simple and inexpensive to use. We plan to license this technology to agricultural equipment manufacturers.
2012-08-01
ACTIVE SAFETY TECHNOLOGY – ENVIRONMENTAL UNDERSTANDING AND NAVIGATION WITH USE OF LOW COST SENSORS David Simon Lockheed Martin MFC, Grand Prairie, TX...Understanding and Navigation with use of low cost sensors 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) David Simon ; Bernard
Perchoux, Julien; Quotb, Adam; Atashkhooei, Reza; Azcona, Francisco J.; Ramírez-Miquet, Evelio E.; Bernal, Olivier; Jha, Ajit; Luna-Arriaga, Antonio; Yanez, Carlos; Caum, Jesus; Bosch, Thierry; Royo, Santiago
2016-01-01
Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current biophotonics research and market trends. The present paper is a review of the work in progress at UPC-CD6 and LAAS-CNRS related to the application of OFI to different aspects of biosensing, both in vivo and ex vivo. This work is intended to present the variety of opportunities and potential applications related to OFI that are available in the field. The activities presented are divided into two main sensing strategies: The measurement of optical path changes and the monitoring of flows, which correspond to sensing strategies linked to the reconstruction of changes of amplitude from the interferometric signal, and to classical Doppler frequency measurements, respectively. For optical path change measurements, measurements of transient pulses, usual in biosensing, together with the measurement of large displacements applied to designing palliative care instrumentation for Parkinson disease are discussed. Regarding the Doppler-based approach, progress in flow-related signal processing and applications in real-time monitoring of non-steady flows, human blood flow monitoring and OFI pressure myograph sensing will be presented. In all cases, experimental setups are discussed and results presented, showing the versatility of the technique. The described applications show the wide capabilities in biosensing of the OFI sensor, showing it as an enabler of low-cost, all-optical, high accuracy biomedical applications. PMID:27187406
Perchoux, Julien; Quotb, Adam; Atashkhooei, Reza; Azcona, Francisco J; Ramírez-Miquet, Evelio E; Bernal, Olivier; Jha, Ajit; Luna-Arriaga, Antonio; Yanez, Carlos; Caum, Jesus; Bosch, Thierry; Royo, Santiago
2016-05-13
Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current biophotonics research and market trends. The present paper is a review of the work in progress at UPC-CD6 and LAAS-CNRS related to the application of OFI to different aspects of biosensing, both in vivo and ex vivo. This work is intended to present the variety of opportunities and potential applications related to OFI that are available in the field. The activities presented are divided into two main sensing strategies: The measurement of optical path changes and the monitoring of flows, which correspond to sensing strategies linked to the reconstruction of changes of amplitude from the interferometric signal, and to classical Doppler frequency measurements, respectively. For optical path change measurements, measurements of transient pulses, usual in biosensing, together with the measurement of large displacements applied to designing palliative care instrumentation for Parkinson disease are discussed. Regarding the Doppler-based approach, progress in flow-related signal processing and applications in real-time monitoring of non-steady flows, human blood flow monitoring and OFI pressure myograph sensing will be presented. In all cases, experimental setups are discussed and results presented, showing the versatility of the technique. The described applications show the wide capabilities in biosensing of the OFI sensor, showing it as an enabler of low-cost, all-optical, high accuracy biomedical applications.
Compact, Low-Noise Magnetic Sensor with Fluxgate (DC) and Induction (AC) Modes of Operation
2009-07-01
induction sensor and the fluxgate magnetometer . ......................................... 2 Figure 3.1 - Impulse response of a 4” long coil (#6...Block diagram of the Year 2, Task 2 fluxgate magnetometer . ................................... 6 Figure 3.3 - FIS-prototype magnetic-field...and demonstrated an innovative dual-mode, fluxgate -induction sensor (FIS) that combines a fluxgate magnetometer and an electromagnetic (EM) induction
Efficient Sensor Integration on Platforms (NeXOS)
NASA Astrophysics Data System (ADS)
Memè, S.; Delory, E.; Del Rio, J.; Jirka, S.; Toma, D. M.; Martinez, E.; Frommhold, L.; Barrera, C.; Pearlman, J.
2016-12-01
In-situ ocean observing platforms provide power and information transmission capability to sensors. Ocean observing platforms can be mobile, such as ships, autonomous underwater vehicles, drifters and profilers, or fixed, such as buoys, moorings and cabled observatories. The process of integrating sensors on platforms can imply substantial engineering time and resources. Constraints range from stringent mechanical constraints to proprietary communication and control firmware. In NeXOS, the implementation of a PUCK plug and play capability is being done with applications to multiple sensors and platforms. This is complemented with a sensor web enablement that addresses the flow of information from sensor to user. Open standards are being tested in order to assess their costs and benefits in existing and future observing systems. Part of the testing implied open-source coding and hardware prototyping of specific control devices in particular for closed commercial platforms where firmware upgrading is not straightforward or possible without prior agreements or service fees. Some platform manufacturers such as European companies ALSEAMAR[1] and NKE Instruments [2] are currently upgrading their control and communication firmware as part of their activities in NeXOS. The sensor development companies Sensorlab[3] SMID[4] and TRIOS [5]upgraded their firmware with this plug and play functionality. Other industrial players in Europe and the US have been sent NeXOS sensors emulators to test the new protocol on their platforms. We are currently demonstrating that with little effort, it is also possible to have such middleware implemented on very low-cost compact computers such as the open Raspberry Pi[6], and have a full end-to-end interoperable communication path from sensor to user with sensor plug and play capability. The result is an increase in sensor integration cost-efficiency and the demonstration will be used to highlight the benefit to users and ocean observatory operators. [1] http://www.alseamar-alcen.com [2] http://www.nke-instrumentation.com [3] http://sensorlab.es [4] http://www.smidtechnology.it/ [5] http://www.trios.de/en/products/ [6] Raspberry Pi is a trademark of the Raspberry Pi Foundation
Low-Cost Air Quality Monitoring Tools: From Research to Practice (A Workshop Summary)
Griswold, William G.; RS, Abhijit; Johnston, Jill E.; Herting, Megan M.; Thorson, Jacob; Collier-Oxandale, Ashley; Hannigan, Michael
2017-01-01
In May 2017, a two-day workshop was held in Los Angeles (California, U.S.A.) to gather practitioners who work with low-cost sensors used to make air quality measurements. The community of practice included individuals from academia, industry, non-profit groups, community-based organizations, and regulatory agencies. The group gathered to share knowledge developed from a variety of pilot projects in hopes of advancing the collective knowledge about how best to use low-cost air quality sensors. Panel discussion topics included: (1) best practices for deployment and calibration of low-cost sensor systems, (2) data standardization efforts and database design, (3) advances in sensor calibration, data management, and data analysis and visualization, and (4) lessons learned from research/community partnerships to encourage purposeful use of sensors and create change/action. Panel discussions summarized knowledge advances and project successes while also highlighting the questions, unresolved issues, and technological limitations that still remain within the low-cost air quality sensor arena. PMID:29143775
Smithard, Joel; Rajic, Nik; van der Velden, Stephen; Norman, Patrick; Rosalie, Cedric; Galea, Steve; Mei, Hanfei; Lin, Bin; Giurgiutiu, Victor
2017-07-20
A key longstanding objective of the Structural Health Monitoring (SHM) research community is to enable the embedment of SHM systems in high value assets like aircraft to provide on-demand damage detection and evaluation. As against traditional non-destructive inspection hardware, embedded SHM systems must be compact, lightweight, low-power and sufficiently robust to survive exposure to severe in-flight operating conditions. Typical Commercial-Off-The-Shelf (COTS) systems can be bulky, costly and are often inflexible in their configuration and/or scalability, which militates against in-service deployment. Advances in electronics have resulted in ever smaller, cheaper and more reliable components that facilitate the development of compact and robust embedded SHM systems, including for Acousto-Ultrasonics (AU), a guided plate-wave inspection modality that has attracted strong interest due mainly to its capacity to furnish wide-area diagnostic coverage with a relatively low sensor density. This article provides a detailed description of the development, testing and demonstration of a new AU interrogation system called the Acousto Ultrasonic Structural health monitoring Array Module⁺ (AUSAM⁺). This system provides independent actuation and sensing on four Piezoelectric Wafer Active Sensor (PWAS) elements with further sensing on four Positive Intrinsic Negative (PIN) photodiodes for intensity-based interrogation of Fiber Bragg Gratings (FBG). The paper details the development of a novel piezoelectric excitation amplifier, which, in conjunction with flexible acquisition-system architecture, seamlessly provides electromechanical impedance spectroscopy for PWAS diagnostics over the full instrument bandwidth of 50 KHz-5 MHz. The AUSAM⁺ functionality is accessed via a simple hardware object providing a myriad of custom software interfaces that can be adapted to suit the specific requirements of each individual application.
Smithard, Joel; Rajic, Nik; Norman, Patrick; Rosalie, Cedric; Galea, Steve; Mei, Hanfei; Lin, Bin; Giurgiutiu, Victor
2017-01-01
A key longstanding objective of the Structural Health Monitoring (SHM) research community is to enable the embedment of SHM systems in high value assets like aircraft to provide on-demand damage detection and evaluation. As against traditional non-destructive inspection hardware, embedded SHM systems must be compact, lightweight, low-power and sufficiently robust to survive exposure to severe in-flight operating conditions. Typical Commercial-Off-The-Shelf (COTS) systems can be bulky, costly and are often inflexible in their configuration and/or scalability, which militates against in-service deployment. Advances in electronics have resulted in ever smaller, cheaper and more reliable components that facilitate the development of compact and robust embedded SHM systems, including for Acousto-Ultrasonics (AU), a guided plate-wave inspection modality that has attracted strong interest due mainly to its capacity to furnish wide-area diagnostic coverage with a relatively low sensor density. This article provides a detailed description of the development, testing and demonstration of a new AU interrogation system called the Acousto Ultrasonic Structural health monitoring Array Module+ (AUSAM+). This system provides independent actuation and sensing on four Piezoelectric Wafer Active Sensor (PWAS) elements with further sensing on four Positive Intrinsic Negative (PIN) photodiodes for intensity-based interrogation of Fiber Bragg Gratings (FBG). The paper details the development of a novel piezoelectric excitation amplifier, which, in conjunction with flexible acquisition-system architecture, seamlessly provides electromechanical impedance spectroscopy for PWAS diagnostics over the full instrument bandwidth of 50 KHz–5 MHz. The AUSAM+ functionality is accessed via a simple hardware object providing a myriad of custom software interfaces that can be adapted to suit the specific requirements of each individual application. PMID:28773193
Ultra-sensitive all-fibre photothermal spectroscopy with large dynamic range
Jin, Wei; Cao, Yingchun; Yang, Fan; Ho, Hoi Lut
2015-01-01
Photothermal interferometry is an ultra-sensitive spectroscopic means for trace chemical detection in gas- and liquid-phase materials. Previous photothermal interferometry systems used free-space optics and have limitations in efficiency of light–matter interaction, size and optical alignment, and integration into photonic circuits. Here we exploit photothermal-induced phase change in a gas-filled hollow-core photonic bandgap fibre, and demonstrate an all-fibre acetylene gas sensor with a noise equivalent concentration of 2 p.p.b. (2.3 × 10−9 cm−1 in absorption coefficient) and an unprecedented dynamic range of nearly six orders of magnitude. The realization of photothermal interferometry with low-cost near infrared semiconductor lasers and fibre-based technology allows a class of optical sensors with compact size, ultra sensitivity and selectivity, applicability to harsh environment, and capability for remote and multiplexed multi-point detection and distributed sensing. PMID:25866015
A Refractive Index Sensor Based on the Resonant Coupling to Cladding Modes in a Fiber Loop
Reyes, Mauricio; Monzón-Hernández, David; Martínez-Ríos, Alejandro; Silvestre, Enrique; Díez, Antonio; Cruz, José Luis; Andrés, Miguel V.
2013-01-01
We report an easy-to-build, compact, and low-cost optical fiber refractive index sensor. It consists of a single fiber loop whose transmission spectra exhibit a series of notches produced by the resonant coupling between the fundamental mode and the cladding modes in a uniformly bent fiber. The wavelength of the notches, distributed in a wavelength span from 1,400 to 1,700 nm, can be tuned by adjusting the diameter of the fiber loop and are sensitive to refractive index changes of the external medium. Sensitivities of 170 and 800 nm per refractive index unit for water solutions and for the refractive index interval 1.40–1.442, respectively, are demonstrated. We estimate a long range resolution of 3 × 10−4 and a short range resolution of 2 × 10−5 for water solutions. PMID:23979478
Low-cost, compact, and robust gas abundance sensor package
NASA Astrophysics Data System (ADS)
Tran, Dat; Nehmetallah, George; Gorius, Nicolas; Ferguson, Frank T.; Esper, Jaime; Johnson, Natasha M.; Aslam, Shahid; Nixon, Conor
2018-05-01
Gas Abundance Sensor Package (GASP) is a stand-alone scientific instrument that has the capability to measure the concentration of target gases based on a non-dispersive infrared sensor system along with atmospheric reference parameters. The main objective of this work is to develop a GASP system which takes advantage of available technologies and off-the-shelf components to provide a cost-effective solution for localized sampling of gas concentrations. GASP will enable scientists to study the atmosphere and will identify the conditions of the target's planetary local environment. Moreover, due to a recent trend of miniaturization of electronic components and thermopiles detectors, a small size and robust instrument with a reduction in power consumption is developed in this work. This allows GASP to be easily integrated into a variety of small space vehicles such as CubeSats or small satellite system, especially the Micro-Reentry Capsule (MIRCA) prototype vehicle. This prototype is one of the most advanced concepts of small satellites that has the capability to survive the rapid dive into the atmosphere of a planet. In this paper, a fully-operational instrument system will be developed and tested in the laboratory environment as well as flight preparation for a field test of the instrument suite will be described.
Development of low-cost high-performance multispectral camera system at Banpil
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.
2014-05-01
Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.
CAIRSENSE Study: Real-world evaluation of low cost sensors in Denver, Colorado
Low-cost air pollution sensors are a rapidly developing field in air monitoring. In recent years, numerous sensors have been developed that can provide real-time concentration data for different air pollutants at costs accessible to individuals and non-regulatory groups. Addition...
Electric-field sensors for bullet detection systems
NASA Astrophysics Data System (ADS)
Vinci, Stephen; Hull, David; Ghionea, Simon; Ludwig, William; Deligeorges, Socrates; Gudmundsson, Thorkell; Noras, Maciej
2014-06-01
Research and experimental trials have shown that electric-field (E-field) sensors are effective at detecting charged projectiles. E-field sensors can likely complement traditional acoustic sensors, and help provide a more robust and effective solution for bullet detection and tracking. By far, the acoustic sensor is the most prevalent technology in use today for hostile fire defeat systems due to compact size and low cost, yet they come with a number of challenges that include multipath, reverberant environments, false positives and low signal-to-noise. Studies have shown that these systems can benefit from additional sensor modalities such as E-field sensors. However, E-field sensors are a newer technology that is relatively untested beyond basic experimental trials; this technology has not been deployed in any fielded systems. The U.S. Army Research Laboratory (ARL) has conducted live-fire experiments at Aberdeen Proving Grounds (APG) to collect data from E-field sensors. Three types of E-field sensors were included in these experiments: (a) an electric potential gradiometer manufactured by Quasar Federal Systems (QFS), (b) electric charge induction, or "D-dot" sensors designed and built by the Army Research Lab (ARL), and (c) a varactor based E-field sensor prototype designed by University of North Carolina-Charlotte (UNCC). Sensors were placed in strategic locations near the bullet trajectories, and their data were recorded. We analyzed the performance of each E-field sensor type in regard to small-arms bullet detection capability. The most recent experiment in October 2013 allowed demonstration of improved versions of the varactor and D-dot sensor types. Results of new real-time analysis hardware employing detection algorithms were also tested. The algorithms were used to process the raw data streams to determine when bullet detections occurred. Performance among the sensor types and algorithm effectiveness were compared to estimates from acoustics signatures and known ground truth. Results, techniques and configurations that might work best for a given sensor platform are discussed.
Zhao, Xihong; Tsao, Yu-Chia; Lee, Fu-Jung; Tsai, Woo-Hu; Wang, Ching-Ho; Chuang, Tsung-Liang; Wu, Mu-Shiang; Lin, Chii-Wann
2016-07-01
A side-polished fiber optic surface plasmon resonance (SPR) sensor was fabricated to expose the core surface and then deposited with a 40 nm thin gold film for the near surface sensing of effective refractive index changes with surface concentration or thickness of captured avian influenza virus subtype H6. The detection surface of the SPR optical fiber sensor was prepared through the plasma modification method for binding a self-assembled monolayer of isopropanol chemically on the gold surface of the optical fiber. Subsequently, N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide/N-hydroxysuccinimide was activated to enable EB2-B3 monoclonal antibodies to capture A/chicken/Taiwan/2838V/00 (H6N1) through a flow injection system. The detection limit of the fabricated optical fiber sensor for A/chicken/Taiwan/2838V/00 was 5.14 × 10(5) EID50/0.1 mL, and the response time was 10 min on average. Moreover, the fiber optic sensor has the advantages of a compact size and low cost, thus rendering it suitable for online and remote sensing. The results indicated that the optical fiber sensor can be used for epidemiological surveillance and diagnosing of avian influenza subtype H6 rapidly. Copyright © 2016 Elsevier B.V. All rights reserved.
Cao, Yuan; Ye, Wenbin; Han, Qingbang; Pan, Xiaofang
2018-01-01
Authentication is a crucial security service for the wireless sensor networks (WSNs) in versatile domains. The deployment of WSN devices in the untrusted open environment and the resource-constrained nature make the on-chip authentication an open challenge. The strong physical unclonable function (PUF) came in handy as light-weight authentication security primitive. In this paper, we present the first ring oscillator (RO) based strong physical unclonable function (PUF) with high resilience to both the electromagnetic (EM) side-channel attack and the support vector machine (SVM) modelling attack. By employing an RO based PUF architecture with the current starved inverter as the delay cell, the oscillation power is significantly reduced to minimize the emitted EM signal, leading to greatly enhanced immunity to the EM side-channel analysis attack. In addition, featuring superior reconfigurability due to the conspicuously simplified circuitries, the proposed implementation is capable of withstanding the SVM modelling attack by generating and comparing a large number of RO frequency pairs. The reported experimental results validate the prototype of a 9-stage RO PUF fabricated using standard 65 nm complementary-metal-oxide-semiconductor (CMOS) process. Operating at the supply voltage of 1.2 V and the frequency of 100 KHz, the fabricated RO PUF occupies a compact silicon area of 250 μm2 and consumes a power as low as 5.16 μW per challenge-response pair (CRP). Furthermore, the uniqueness and the worst-case reliability are measured to be 50.17% and 98.30% for the working temperature range of −40∼120 ∘C and the supply voltage variation of ±2%, respectively. Thus, the proposed PUF is applicable for the low power, low cost and secure WSN communications. PMID:29360790
Cao, Yuan; Zhao, Xiaojin; Ye, Wenbin; Han, Qingbang; Pan, Xiaofang
2018-01-23
Authentication is a crucial security service for the wireless sensor networks (WSNs) in versatile domains. The deployment of WSN devices in the untrusted open environment and the resource-constrained nature make the on-chip authentication an open challenge. The strong physical unclonable function (PUF) came in handy as light-weight authentication security primitive. In this paper, we present the first ring oscillator (RO) based strong physical unclonable function (PUF) with high resilience to both the electromagnetic (EM) side-channel attack and the support vector machine (SVM) modelling attack. By employing an RO based PUF architecture with the current starved inverter as the delay cell, the oscillation power is significantly reduced to minimize the emitted EM signal, leading to greatly enhanced immunity to the EM side-channel analysis attack. In addition, featuring superior reconfigurability due to the conspicuously simplified circuitries, the proposed implementation is capable of withstanding the SVM modelling attack by generating and comparing a large number of RO frequency pairs. The reported experimental results validate the prototype of a 9-stage RO PUF fabricated using standard 65 nm complementary-metal-oxide-semiconductor (CMOS) process. Operating at the supply voltage of 1.2 V and the frequency of 100 KHz, the fabricated RO PUF occupies a compact silicon area of 250 μ m 2 and consumes a power as low as 5.16 μ W per challenge-response pair (CRP). Furthermore, the uniqueness and the worst-case reliability are measured to be 50.17% and 98.30% for the working temperature range of -40∼120 ∘ C and the supply voltage variation of ±2%, respectively. Thus, the proposed PUF is applicable for the low power, low cost and secure WSN communications.
NASA Astrophysics Data System (ADS)
Bratcher, Tim; Kroutil, Robert; Lanouette, André; Lewis, Paul E.; Miller, David; Shen, Sylvia; Thomas, Mark
2013-05-01
The development concept paper for the MSIC system was first introduced in August 2012 by these authors. This paper describes the final assembly, testing, and commercial availability of the Mapping System Interface Card (MSIC). The 2.3kg MSIC is a self-contained, compact variable configuration, low cost real-time precision metadata annotator with embedded INS/GPS designed specifically for use in small aircraft. The MSIC was specifically designed to convert commercial-off-the-shelf (COTS) digital cameras and imaging/non-imaging spectrometers with Camera Link standard data streams into mapping systems for airborne emergency response and scientific remote sensing applications. COTS digital cameras and imaging/non-imaging spectrometers covering the ultraviolet through long-wave infrared wavelengths are important tools now readily available and affordable for use by emergency responders and scientists. The MSIC will significantly enhance the capability of emergency responders and scientists by providing a direct transformation of these important COTS sensor tools into low-cost real-time aerial mapping systems.
NASA Astrophysics Data System (ADS)
Shahiduzzaman, Md.; Furumoto, Yoshikazu; Yamamoto, Kohei; Yonezawa, Kyosuke; Azuma, Yosuke; Kitamura, Michinori; Matsuzaki, Hiroyuki; Karakawa, Makoto; Kuwabara, Takayuki; Takahashi, Kohshin; Taima, Tetsuya
2018-03-01
The fabrication of high-efficiency solution-processable perovskite solar cells has been achieved using mesostructured films and compact titanium dioxide (TiO2) layers in a process that involves high temperatures and cost. Here, we present an efficient approach for fabricating chemical-bath-deposited, low-temperature, and low-cost amorphous compact TiO x -based planar heterojunction perovskite solar cells by one-step and two-step coatings of the perovskite layer. We also investigate the effect of the number of perovskite coating steps on the compact TiO x layer. The grazing incidence wide-angle X-ray scattering technique is used to clarify the relationship between morphology, crystallinity, and photovoltaic properties of the resulting devices. Analysis of the films revealed that one-step spin-coating of perovskite exhibited an enhancement of film quality and crystallization that correlates to photovoltaic performance 1.5 times higher than that of a two-step-coated device. Our findings show that the resulting morphology, crystallinity, and device performances are strongly dependent on the number of coating steps of the perovskite thin layer on the compact TiO x layer. This result is useful knowledge for the low-cost production of planar perovskite solar cells.
Fiber-Optic Temperature Sensor Using a Thin-Film Fabry-Perot Interferometer
NASA Technical Reports Server (NTRS)
Beheim, Glenn
1997-01-01
A fiber-optic temperature sensor was developed that is rugged, compact, stable, and can be inexpensively fabricated. This thin-film interferometric temperature sensor was shown to be capable of providing a +/- 2 C accuracy over the range of -55 to 275 C, throughout a 5000 hr operating life. A temperature-sensitive thin-film Fabry-Perot interferometer can be deposited directly onto the end of a multimode optical fiber. This batch-fabricatable sensor can be manufactured at a much lower cost than can a presently available sensor, which requires the mechanical attachment of a Fabry-Perot interferometer to a fiber. The principal disadvantage of the thin-film sensor is its inherent instability, due to the low processing temperatures that must be used to prevent degradation of the optical fiber's buffer coating. The design of the stable thin-film temperature sensor considered the potential sources of both short and long term drifts. The temperature- sensitive Fabry-Perot interferometer was a silicon film with a thickness of approx. 2 microns. A laser-annealing process was developed which crystallized the silicon film without damaging the optical fiber. The silicon film was encapsulated with a thin layer of Si3N4 over coated with aluminum. Crystallization of the silicon and its encapsulation with a highly stable, impermeable thin-film structure were essential steps in producing a sensor with the required long-term stability.
Tritium-powered radiation sensor network
NASA Astrophysics Data System (ADS)
Litz, Marc S.; Russo, Johnny A.; Katsis, Dimos
2016-05-01
Isotope power supplies offer long-lived (100 years using 63Ni), low-power energy sources, enabling sensors or communications nodes for the lifetime of infrastructure. A tritium beta-source (12.5-year half-life) encapsulated in a phosphor-lined vial couples directly to a photovoltaic (PV) to generate a trickle current into an electrical load. An inexpensive design is described using commercial-of-the-shelf (COTS) components that generate 100 μWe for nextgeneration compact electronics/sensors. A matched radiation sensor has been built for long-duration missions utilizing microprocessor-controlled sleep modes, low-power electronic components, and a passive interrupt driven environmental wake-up. The low-power early-warning radiation detector network and isotope power source enables no-maintenance mission lifetimes.
NASA Astrophysics Data System (ADS)
Mendoza, Edgar; Prohaska, John; Kempen, Connie; Esterkin, Yan; Sun, Sunjian; Krishnaswamy, Sridhar
2010-09-01
This paper describes preliminary results obtained under a Navy SBIR contract by Redondo Optics Inc. (ROI), in collaboration with Northwestern University towards the development and demonstration of a next generation, stand-alone and fully integrated, dynamically reconfigurable, adaptive fiber optic acoustic emission sensor (FAESense™) system for the in-situ unattended detection and localization of shock events, impact damage, cracks, voids, and delaminations in new and aging critical infrastructures found in ships, submarines, aircraft, and in next generation weapon systems. ROI's FAESense™ system is based on the integration of proven state-of-the-art technologies: 1) distributed array of in-line fiber Bragg gratings (FBGs) sensors sensitive to strain, vibration, and acoustic emissions, 2) adaptive spectral demodulation of FBG sensor dynamic signals using two-wave mixing interferometry on photorefractive semiconductors, and 3) integration of all the sensor system passive and active optoelectronic components within a 0.5-cm x 1-cm photonic integrated circuit microchip. The adaptive TWM demodulation methodology allows the measurement of dynamic high frequnency acoustic emission events, while compensating for passive quasi-static strain and temperature drifts. It features a compact, low power, environmentally robust 1-inch x 1-inch x 4-inch small form factor (SFF) package with no moving parts. The FAESense™ interrogation system is microprocessor-controlled using high data rate signal processing electronics for the FBG sensors calibration, temperature compensation and the detection and analysis of acoustic emission signals. Its miniaturized package, low power operation, state-of-the-art data communications, and low cost makes it a very attractive solution for a large number of applications in naval and maritime industries, aerospace, civil structures, the oil and chemical industry, and for homeland security applications.
Application of ion-sensitive sensors in water quality monitoring.
Winkler, S; Rieger, L; Saracevic, E; Pressl, A; Gruber, G
2004-01-01
Within the last years a trend towards in-situ monitoring can be observed, i.e. most new sensors for water quality monitoring are designed for direct installation in the medium, compact in size and use measurement principles which minimise maintenance demand. Ion-sensitive sensors (Ion-Sensitive-Electrode--ISE) are based on a well known measurement principle and recently some manufacturers have released probe types which are specially adapted for application in water quality monitoring. The function principle of ISE-sensors, their advantages, limitations and the different methods for sensor calibration are described. Experiences with ISE-sensors from applications in sewer networks, at different sampling points within wastewater treatment plants and for surface water monitoring are reported. An estimation of investment and operation costs in comparison to other sensor types is given.
Lu, Qiang; Liu, Guanghui; Xiao, Chuanli; Hu, Chuanzhen; Zhang, Shiwu; Xu, Ronald X.; Chu, Kaiqin; Xu, Qianming
2018-01-01
In this paper we report the development of a cost-effective, modular, open source, and fully automated slide-scanning microscope, composed entirely of easily available off-the-shelf parts, and capable of bright field and fluorescence modes. The automated X-Y stage is composed of two low-cost micrometer stages coupled to stepper motors operated in open-loop mode. The microscope is composed of a low-cost CMOS sensor and low-cost board lenses placed in a 4f configuration. The system has approximately 1 micron resolution, limited by the f/# of available board lenses. The microscope is compact, measuring just 25×25×30 cm, and has an absolute positioning accuracy of ±1 μm in the X and Y directions. A Z-stage enables autofocusing and imaging over large fields of view even on non-planar samples, and custom software enables automatic determination of sample boundaries and image mosaicking. We demonstrate the utility of our device through imaging of fluorescent- and transmission-dye stained blood and fecal smears containing human and animal parasites, as well as several prepared tissue samples. These results demonstrate image quality comparable to high-end commercial microscopes at a cost of less than US$400 for a bright-field system, with an extra US$100 needed for the fluorescence module. PMID:29543835
Glucose sensor realized with photonic crystal fiber-based Sagnac interferometer
NASA Astrophysics Data System (ADS)
An, Guowen; Li, Shuguang; An, Yinghong; Wang, Haiyang; Zhang, Xuenan
2017-12-01
A compact glucose sensor is proposed by using a short length of photonic crystal fiber inserted in a Sagnac loop interferometer. Spectrum shift in response to the RI of glucose solution with a high average sensitivity of 22 130 nm/RIU is achieved, equivalent to 0.76 mg/dL of glucose in water, which is lower than 70 mg/dL for efficient detection of hypoglycemia episodes. And the simplicity of the fiber structure makes the sensor production very cost effective. We aimed to provide a potential effective method for glucose detection in patients with hypoglycemia.
Low cost sensors: Field evaluations and multi-sensor approaches for emissions factors
The development, and application of low cost sensors to measure both particulate and gas-phase air pollutants is poised to explode over the next several years. The need for the sensors is driven by poor air quality experienced in inhabited regions throughout the world, in both de...
Development of a Low-Cost Attitude Sensor for Agricultural Vehicles
USDA-ARS?s Scientific Manuscript database
The objective of this research was to develop a low-cost attitude sensor for agricultural vehicles. The attitude sensor was composed of three vibratory gyroscopes and two inclinometers. A sensor fusion algorithm was developed to estimate tilt angles (roll and pitch) by least-squares method. In the a...
Wang, Tiantian; Kim, Sanghyo; An, Jeong Ho
2017-02-01
Loop-mediated isothermal amplification (LAMP) is considered as one of the alternatives to the conventional PCR and it is an inexpensive portable diagnostic system with minimal power consumption. The present work describes the application of LAMP in real-time photon detection and quantitative analysis of nucleic acids integrated with a disposable complementary-metal-oxide semiconductor (CMOS) image sensor. This novel system works as an amplification-coupled detection platform, relying on a CMOS image sensor, with the aid of a computerized circuitry controller for the temperature and light sources. The CMOS image sensor captures the light which is passing through the sensor surface and converts into digital units using an analog-to-digital converter (ADC). This new system monitors the real-time photon variation, caused by the color changes during amplification. Escherichia coli O157 was used as a proof-of-concept target for quantitative analysis, and compared with the results for Staphylococcus aureus and Salmonella enterica to confirm the efficiency of the system. The system detected various DNA concentrations of E. coli O157 in a short time (45min), with a detection limit of 10fg/μL. The low-cost, simple, and compact design, with low power consumption, represents a significant advance in the development of a portable, sensitive, user-friendly, real-time, and quantitative analytic tools for point-of-care diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Photoionization sensors for non-invasive medical diagnostics
NASA Astrophysics Data System (ADS)
Mustafaev, Aleksandr; Rastvorova, Iuliia; Khobnya, Kristina; Podenko, Sofia
2016-09-01
The analysis of biomarkers can help to identify the significant number of diseases: lung cancer, tuberculosis, diabetes, high levels of stress, psychosomatic disorders etc. To implement continuous monitoring of the state of human health, compact VUV photoionization detector with current-voltage measurement is designed by Saint-Petersburg Mining University Plasma Research Group. This sensor is based on the patented method of stabilization of electric parameters - CES (Collisional Electron Spectroscopy). During the operation at atmospheric pressure VUV photoionization sensor measures the energy of electrons, produced in the ionization with the resonance photons, whose wavelength situated in the vacuum ultraviolet (VUV). A special software was developed to obtain the second-order derivative of the I-U characteristics, taken by the VUV sensor, to construct the energy spectra of the characteristic electrons. VUV photoionization detector has an unique set of parameters: small size (10*10*1 mm), low cost, wide range of recognizable molecules, as well as accuracy, sufficient for using this instrument for the medical purposes. This device can be used for non-invasive medical diagnostics without compromising the quality of life, for control of environment and human life. Work supported by Foundation for Assistance to Small Innovative Enterprises in Science and Technology.
Ce doped NiO nanoparticles as selective NO2 gas sensor
NASA Astrophysics Data System (ADS)
Gawali, Swati R.; Patil, Vithoba L.; Deonikar, Virendrakumar G.; Patil, Santosh S.; Patil, Deepak R.; Patil, Pramod S.; Pant, Jayashree
2018-03-01
Metal oxide gas sensors are promising portable gas detection devices because of their advantages such as low cost, easy production and compact size. The performance of such sensors is strongly dependent on material properties such as morphology, structure and doping. In the present study, we report the effect of cerium (Ce) doping on nickel oxide (NiO) nano-structured thin film sensors towards various gases. Bare NiO and Ce doped NiO nanoparticles (Ce:NiO) were synthesized by sol-gel method. To understand the effect of Ce doping in nickel oxide, various molar percentages of Ce with respect to nickel were incorporated. The structure, phase, morphology and band-gap energy of as-synthesized nanoparticles were studied by XRD, SEM, EDAX and UV-vis spectroscopy. Thin film gas sensors of all the samples were prepared and subjected to various gases such as LPG, NH3, CH3COCH3 and NO2. A systematic and comparative study reveals an enhanced gas sensing performance of Ce:NiO sensors towards NO2 gas. The maximum sensitivity for NO2 gas is around 0.719% per ppm at moderate operating temperature of 150 °C for 0.5% Ce:NiO thin film gas sensor. The enhanced gas sensing performance for Ce:NiO is attributed to the distortion of crystal lattice caused by doping of Ce into NiO.
Design of sensor node platform for wireless biomedical sensor networks.
Xijun, Chen; -H Meng, Max; Hongliang, Ren
2005-01-01
Design of low-cost, miniature, lightweight, ultra low-power, flexible sensor platform capable of customization and seamless integration into a wireless biomedical sensor network(WBSN) for health monitoring applications presents one of the most challenging tasks. In this paper, we propose a WBSN node platform featuring an ultra low-power microcontroller, an IEEE 802.15.4 compatible transceiver, and a flexible expansion connector. The proposed solution promises a cost-effective, flexible platform that allows easy customization, energy-efficient computation and communication. The development of a common platform for multiple physical sensors will increase reuse and alleviate costs of transition to a new generation of sensors. As a case study, we present an implementation of an ECG (Electrocardiogram) sensor.
Safe Detection System for Hydrogen Leaks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lieberman, Robert A.; Beshay, Manal
2012-02-29
Hydrogen is an "environmentally friendly" fuel for future transportation and other applications, since it produces only pure ("distilled") water when it is consumed. Thus, hydrogen-powered vehicles are beginning to proliferate, with the total number of such vehicles expected to rise to nearly 100,000 within the next few years. However, hydrogen is also an odorless, colorless, highly flammable gas. Because of this, there is an important need for hydrogen safety monitors that can warn of hazardous conditions in vehicles, storage facilities, and hydrogen production plants. To address this need, IOS has developed a unique intrinsically safe optical hydrogen sensing technology, andmore » has embodied it in detector systems specifically developed for safety applications. The challenge of using light to detect a colorless substance was met by creating chemically-sensitized optical materials whose color changes in the presence of hydrogen. This reversible reaction provides a sensitive, reliable, way of detecting hydrogen and measuring its concentration using light from low-cost LEDs. Hydrogen sensors based on this material were developed in three completely different optical formats: point sensors ("optrodes"), integrated optic sensors ("optical chips"), and optical fibers ("distributed sensors") whose entire length responds to hydrogen. After comparing performance, cost, time-to-market, and relative market need for these sensor types, the project focused on designing a compact optrode-based single-point hydrogen safety monitor. The project ended with the fabrication of fifteen prototype units, and the selection of two specific markets: fuel cell enclosure monitoring, and refueling/storage safety. Final testing and development of control software for these markets await future support.« less
Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.
2014-01-01
Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0–10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation. PMID:25126153
NASA Astrophysics Data System (ADS)
Williams, George M.
2017-03-01
Newly emerging accident-reducing, driver-assistance, and autonomous-navigation technology for automobiles is based on real-time three-dimensional mapping and object detection, tracking, and classification using lidar sensors. Yet, the lack of lidar sensors suitable for meeting application requirements appreciably limits practical widespread use of lidar in trucking, public livery, consumer cars, and fleet automobiles. To address this need, a system-engineering perspective to eyesafe lidar-system design for high-level advanced driver-assistance sensor systems and a design trade study including 1.5-μm spot-scanned, line-scanned, and flash-lidar systems are presented. A cost-effective lidar instrument design is then proposed based on high-repetition-rate diode-pumped solid-state lasers and high-gain, low-excess-noise InGaAs avalanche photodiode receivers and focal plane arrays. Using probabilistic receiver-operating-characteristic analysis, derived from measured component performance, a compact lidar system is proposed that is capable of 220 m ranging with 5-cm accuracy, which can be readily scaled to a 360-deg field of regard.
Castillo, Encarnación; López-Ramos, Juan A.; Morales, Diego P.
2018-01-01
Security is a critical challenge for the effective expansion of all new emerging applications in the Internet of Things paradigm. Therefore, it is necessary to define and implement different mechanisms for guaranteeing security and privacy of data interchanged within the multiple wireless sensor networks being part of the Internet of Things. However, in this context, low power and low area are required, limiting the resources available for security and thus hindering the implementation of adequate security protocols. Group keys can save resources and communications bandwidth, but should be combined with public key cryptography to be really secure. In this paper, a compact and unified co-processor for enabling Elliptic Curve Cryptography along to Advanced Encryption Standard with low area requirements and Group-Key support is presented. The designed co-processor allows securing wireless sensor networks with independence of the communications protocols used. With an area occupancy of only 2101 LUTs over Spartan 6 devices from Xilinx, it requires 15% less area while achieving near 490% better performance when compared to cryptoprocessors with similar features in the literature. PMID:29337921
Parrilla, Luis; Castillo, Encarnación; López-Ramos, Juan A; Álvarez-Bermejo, José A; García, Antonio; Morales, Diego P
2018-01-16
Security is a critical challenge for the effective expansion of all new emerging applications in the Internet of Things paradigm. Therefore, it is necessary to define and implement different mechanisms for guaranteeing security and privacy of data interchanged within the multiple wireless sensor networks being part of the Internet of Things. However, in this context, low power and low area are required, limiting the resources available for security and thus hindering the implementation of adequate security protocols. Group keys can save resources and communications bandwidth, but should be combined with public key cryptography to be really secure. In this paper, a compact and unified co-processor for enabling Elliptic Curve Cryptography along to Advanced Encryption Standard with low area requirements and Group-Key support is presented. The designed co-processor allows securing wireless sensor networks with independence of the communications protocols used. With an area occupancy of only 2101 LUTs over Spartan 6 devices from Xilinx, it requires 15% less area while achieving near 490% better performance when compared to cryptoprocessors with similar features in the literature.
Development and Implementation of Low-Cost Mobile Sensor Platforms Within a Wireless Sensor Network
2010-09-01
WIRELESS SENSOR NETWORK by Michael Jay Tozzi September 2010 Thesis Advisor: Rachel Goshorn Second Reader: Duane Davis Approved for...Platforms Within a Wireless Sensor Network 6. AUTHOR(S) Tozzi, Michael Jay 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval...IMPLEMENTATION OF LOW-COST MOBILE SENSOR PLATFORMS WITHIN A WIRELESS SENSOR NETWORK Michael Jay Tozzi Lieutenant, United States Navy B.S., United
A microcomputer-based daily living activity recording system.
Matsuoka, Shingo; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Thayer, Julian F; Caldwell, W Morton
2003-01-01
A new daily living activity recording system has been developed for monitoring health conditions and living patterns, such as respiration, posture, activity/rest ratios and general activity level. The system employs a piezoelectric sensor, a dual axis accelerometer, two low-power active filters, a low-power 8-bit single chip microcomputer and a 128 MB compact flash memory. The piezoelectric sensor, whose electrical polarization voltage is produced by mechanical strain, detects body movements. Its high-frequency output components reflect body movements produced by walking and running activities, while the low frequency components are mainly respiratory. The dual axis accelerometer detects, from body X and Y tilt angles, whether the patient is standing, sitting or lying down (prone, supine, left side or right side). The detected respiratory, behavior and posture signals are stored by the compact flash memory. After recording, these data are downloaded to a desktop computer and analyzed.
Extended Logic Intelligent Processing System for a Sensor Fusion Processor Hardware
NASA Technical Reports Server (NTRS)
Stoica, Adrian; Thomas, Tyson; Li, Wei-Te; Daud, Taher; Fabunmi, James
2000-01-01
The paper presents the hardware implementation and initial tests from a low-power, highspeed reconfigurable sensor fusion processor. The Extended Logic Intelligent Processing System (ELIPS) is described, which combines rule-based systems, fuzzy logic, and neural networks to achieve parallel fusion of sensor signals in compact low power VLSI. The development of the ELIPS concept is being done to demonstrate the interceptor functionality which particularly underlines the high speed and low power requirements. The hardware programmability allows the processor to reconfigure into different machines, taking the most efficient hardware implementation during each phase of information processing. Processing speeds of microseconds have been demonstrated using our test hardware.
Feasibility of fatigue crack detection and tracking with a multi-sensor in-situ monitoring system
NASA Astrophysics Data System (ADS)
Zhao, Xiaoliang; Qi, Kevin; Qian, Tao; Mei, Gang
2014-02-01
Fatigue crack is a common problem for steel bridges. A cost effective and reliable method for detecting and verifying growth of a crack is desired. In this work, feasibilities of fatigue crack monitoring with acoustic emission sensors and strain gauges were studied on an A36 steel compact-tension coupon under cyclic tensile loading. By examining the ultrasonic signal time-of-arrival and frequency spectrum, acoustic emissions from a crack growth can be distinguished from other structural borne noises such as those from the interaction of loading bolts with the bolt holes on the plate. Strain sensor and clip gauge sensor data were also correlated well with the growth of the crack.
Measuring NO, NO2, CO2 and O3 with low-cost sensors
NASA Astrophysics Data System (ADS)
Müller, Michael; Graf, Peter; Hüglin, Christoph
2017-04-01
Inexpensive sensors measuring ambient gas concentrations can be integrated in sensor units forming dense sensor networks. The utilized sensors have to be sufficiently accurate as the value of such networks directly depends on the information they provide. Thus, thorough testing of sensors before bringing them into service and the application of effective strategies for performance monitoring and adjustments during service are key elements for operating the low-cost sensors that are currently available on the market. We integrated several types of low-cost sensors into sensor units (Alphasense NO2 B4/B42F/B43F, Alphasense NO B4, SensAir CO2 LP8, Aeroqual O3 SM50), run them in the field next to instruments of air quality monitoring stations and performed tests in the laboratory. The poster summarizes our findings regarding the achieved sensor accuracy, methods to improve sensor performance as well as strategies to monitor the current state of the sensor (drifts, sensitivity) within a sensor network.
Low-cost human motion capture system for postural analysis onboard ships
NASA Astrophysics Data System (ADS)
Nocerino, Erica; Ackermann, Sebastiano; Del Pizzo, Silvio; Menna, Fabio; Troisi, Salvatore
2011-07-01
The study of human equilibrium, also known as postural stability, concerns different research sectors (medicine, kinesiology, biomechanics, robotics, sport) and is usually performed employing motion analysis techniques for recording human movements and posture. A wide range of techniques and methodologies has been developed, but the choice of instrumentations and sensors depends on the requirement of the specific application. Postural stability is a topic of great interest for the maritime community, since ship motions can make demanding and difficult the maintenance of the upright stance with hazardous consequences for the safety of people onboard. The need of capturing the motion of an individual standing on a ship during its daily service does not permit to employ optical systems commonly used for human motion analysis. These sensors are not designed for operating in disadvantageous environmental conditions (water, wetness, saltiness) and with not optimal lighting. The solution proposed in this study consists in a motion acquisition system that could be easily usable onboard ships. It makes use of two different methodologies: (I) motion capture with videogrammetry and (II) motion measurement with Inertial Measurement Unit (IMU). The developed image-based motion capture system, made up of three low-cost, light and compact video cameras, was validated against a commercial optical system and then used for testing the reliability of the inertial sensors. In this paper, the whole process of planning, designing, calibrating, and assessing the accuracy of the motion capture system is reported and discussed. Results from the laboratory tests and preliminary campaigns in the field are presented.
CAIRSENSE Study: Real-world evaluation of low cost sensors ...
Low-cost air pollution sensors are a rapidly developing field in air monitoring. In recent years, numerous sensors have been developed that can provide real-time concentration data for different air pollutants at costs accessible to individuals and non-regulatory groups. Additionally, these sensors have the potential to improve the spatial resolution of monitoring networks and provide a better understanding of neighborhood- and local-scale air quality and sources. However, many new sensors have not been evaluated to determine their long-term performance and capabilities. In this study, nine different low-cost sensor models, including O3, NO2 and particle sensors, were deployed in Denver, CO from September 2015 to February 2016. Three sensors of each type were deployed to evaluate instrument precision and consistency over the time period. Sensors were co-located with reference monitors at the Denver NCore site in order to evaluate sensor accuracy and precision. Denver was chosen as the location for this study to evaluate sensor performance in dry, high altitude, and low winter temperatures. Sensors were evaluated for data completeness, performance over time, and comparison with regulatory monitors. This presentation will also address challenges and approaches to data logging and processing. Preliminary analysis revealed that most sensors had high data completeness when data loggers were operational (e.g., the Aeroqual O3 sensor ranged from 94-100%), and exhibited
Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.
Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid
2017-03-01
This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.
Miniature and low cost fiber Bragg grating interrogator for structural monitoring in nano-satellites
NASA Astrophysics Data System (ADS)
Toet, P. M.; Hagen, R. A. J.; Hakkesteegt, H. C.; Lugtenburg, J.; Maniscalco, M. P.
2017-11-01
In this paper we present a newly developed Fiber Optic measurement system, consisting of Fiber Bragg Grating (FBG) sensors and an FBG interrogator. The development of the measuring system is part of the PiezoElectric Assisted Smart Satellite Structure (PEASSS) project, which was initiated at the beginning of 2013 and is financed by the Seventh Framework Program (FP7) of the European Commission. Within the PEASSS project, a Nano-Satellite is being designed and manufactured to be equipped with new technology that will help keep Europe on the cutting edge of space research, potentially reducing the cost and development time for more accurate future sensor platforms including synthetic aperture optics, moving target detection and identification, and compact radars. After on ground testing the satellite is planned to be launched at the end of 2015. Within the satellite, different technologies will be demonstrated on orbit to show their capabilities for different in-space applications. For our application the FBG interrogator monitors the structural and thermal behaviour of a so called "smart panel". These panels will enable fine angle control and thermal and vibration compensation in order to improve all types of future Earth observations, such as environmental and planetary mapping, border and regional imaging. The Fiber Optic (FO) system in PEASSS includes four FBG strain sensors and two FBG temperature sensors. The 3 channel interrogator has to have a small footprint (110x50x40mm), is low cost, low in mass and has a low power consumption. In order to meet all these requirements, an interrogator has been designed based on a tunable Vertical-Cavity Surface-Emitting Laser (VCSEL) enabling a wavelength sweep of around 7 nm. To guarantee the absolute and relative performance, two reference methods are included internally in the interrogator. First, stabilized reference FBG sensors are used to obtain absolute wavelength calibrations. This method is used for the temperature sensors in the system, which will be measured with an accuracy of +/-1°C. Second, the strain sensors will be used to monitor deformation of piezo actuators (bimorph plates) in a way that temperature compensation is not required. Using FBGs on top and on the bottom of the plates, relative wavelength differences are measured. In order to have a high accuracy, inside the interrogator a fiber interferometer is used to track the wavelength change. Using this reference technology we are able to measure the (relative) wavelength difference between two FBGs well below 0.1pm.
Acoustic Transmitters for Underwater Neutrino Telescopes
Ardid, Miguel; Martínez-Mora, Juan A.; Bou-Cabo, Manuel; Larosa, Giuseppina; Adrián-Martínez, Silvia; Llorens, Carlos D.
2012-01-01
In this paper acoustic transmitters that were developed for use in underwater neutrino telescopes are presented. Firstly, an acoustic transceiver has been developed as part of the acoustic positioning system of neutrino telescopes. These infrastructures are not completely rigid and require a positioning system in order to monitor the position of the optical sensors which move due to sea currents. To guarantee a reliable and versatile system, the transceiver has the requirements of reduced cost, low power consumption, high pressure withstanding (up to 500 bars), high intensity for emission, low intrinsic noise, arbitrary signals for emission and the capacity of acquiring and processing received signals. Secondly, a compact acoustic transmitter array has been developed for the calibration of acoustic neutrino detection systems. The array is able to mimic the signature of ultra-high-energy neutrino interaction in emission directivity and signal shape. The technique of parametric acoustic sources has been used to achieve the proposed aim. The developed compact array has practical features such as easy manageability and operation. The prototype designs and the results of different tests are described. The techniques applied for these two acoustic systems are so powerful and versatile that may be of interest in other marine applications using acoustic transmitters. PMID:22666022
Abraham, Jose K; Sullivan, Shawn; Ranganathan, Sridhar
2011-01-01
Sleep has profound effects on the physical and mental well-being of an individual. The National Institutes of Health (NIH) Sleep Disorder Research Plan gives particular emphasis to non-invasive sleep monitoring methods. Older adults experience sleep fragmentation due to sleep disorders. Unobtrusive non-contact monitoring can be the only realistic solution for long term home-based sleep monitoring. The demand for a low-cost and non-invasive sleep monitoring system for in-home use is more than before due to an increasingly stressful life style. Cost and complexity of current sensor elements hinder the development of low-cost sleep monitoring devices for in-home use. This paper presents the design, development and implementation of a low-cost and disposable pressure sensor mat that could be useful for in-home sleep and movement monitoring applications. The sensor mat design is based on a compressible foam sandwiched between two orthogonal arrays of cPaper capacitance sensors. A low-cost conducting paper has been developed for use as the capacitance sensor electrode. Typical mat design uses a 3 mm thick foam with 5 mm row/column grid array shows that it has a measurement resolution of 0.1 PSI pressure. The resolution can be controlled by both modifying properties of the conducting paper and the foam. Since this pressure mat design is based on low-cost paper, the sensor electrodes are disposable or semi-durable and hence it is ideal for the use in point-of-care physiological monitoring, pervasive healthcare and consumer electronic devices.
Reconfigurable intelligent sensors for health monitoring: a case study of pulse oximeter sensor.
Jovanov, E; Milenkovic, A; Basham, S; Clark, D; Kelley, D
2004-01-01
Design of low-cost, miniature, lightweight, ultra low-power, intelligent sensors capable of customization and seamless integration into a body area network for health monitoring applications presents one of the most challenging tasks for system designers. To answer this challenge we propose a reconfigurable intelligent sensor platform featuring a low-power microcontroller, a low-power programmable logic device, a communication interface, and a signal conditioning circuit. The proposed solution promises a cost-effective, flexible platform that allows easy customization, run-time reconfiguration, and energy-efficient computation and communication. The development of a common platform for multiple physical sensors and a repository of both software procedures and soft intellectual property cores for hardware acceleration will increase reuse and alleviate costs of transition to a new generation of sensors. As a case study, we present an implementation of a reconfigurable pulse oximeter sensor.
Multi-Parameter Aerosol Scattering Sensor
NASA Technical Reports Server (NTRS)
Greenberg, Paul S.; Fischer, David G.
2011-01-01
This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration
Low-cost embedded systems for democratizing ocean sensor technology in the coastal zone
NASA Astrophysics Data System (ADS)
Glazer, B. T.; Lio, H. I.
2017-12-01
Environmental sciences suffer from undersampling. Enabling sustained and unattended data collection in the coastal zone typically involves expensive instrumentation and infrastructure deployed as cabled observatories or moorings with little flexibility in deployment location following initial installation. High costs of commercially-available or custom instruments have limited the number of sensor sites that can be targeted by academic researchers, and have also limited engagement with the public. We have developed a novel, low-cost, open-source sensor and software platform to enable wireless data transfer of biogeochemical sensors in the coastal zone. The platform is centered upon widely available, low-cost, single board computers and microcontrollers. We have used a blend of on-hand research-grade sensors and low-cost open-source electronics that can be assembled by tech-savvy non-engineers. Robust, open-source code that remains customizable for specific miniNode configurations can match a specific site's measurement needs, depending on the scientific research priorities. We have demonstrated prototype capabilities and versatility through lab testing and field deployments of multiple sensor nodes with multiple sensor inputs, all of which are streaming near-real-time data from Kaneohe Bay over wireless RF links to a shore-based base station.
Advances in air pollution sensor technology have enabled the development of small and low cost systems to measure outdoor air pollution. The deployment of a large number of sensors across a small geographic area would have potential benefits to supplement traditional monitoring n...
Japanese Ubiquotous Network Project: Ubila
NASA Astrophysics Data System (ADS)
Ohashi, Masayoshi
Recently, the advent of sophisticated technologies has stimulated ambient paradigms that may include high-performance CPU, compact real-time operating systems, a variety of devices/sensors, low power and high-speed radio communications, and in particular, third generation mobile phones. In addition, due to the spread of broadband ccess networks, various ubiquitous terminals and sensors can be connected closely.
Ammonia Optical Sensing by Microring Resonators
Passaro, Vittorio M. N.; Dell'Olio, Francesco; De Leonardis, Francesco
2007-01-01
A very compact (device area around 40 μm2) optical ammonia sensor based on a microring resonator is presented in this work. Silicon-on-insulator technology is used in sensor design and a dye doped polymer is adopted as sensing material. The sensor exhibits a very good linearity and a minimum detectable refractive index shift of sensing material as low as 8×10-5, with a detection limit around 4 ‰. PMID:28903258
Simulation analysis of a microcomputer-based, low-cost Omega navigation system
NASA Technical Reports Server (NTRS)
Lilley, R. W.; Salter, R. J., Jr.
1976-01-01
The current status of research on a proposed micro-computer-based, low-cost Omega Navigation System (ONS) is described. The design approach emphasizes minimum hardware, maximum software, and the use of a low-cost, commercially-available microcomputer. Currently under investigation is the implementation of a low-cost navigation processor and its interface with an omega sensor to complete the hardware-based ONS. Sensor processor functions are simulated to determine how many of the sensor processor functions can be handled by innovative software. An input data base of live Omega ground and flight test data was created. The Omega sensor and microcomputer interface modules used to collect the data are functionally described. Automatic synchronization to the Omega transmission pattern is described as an example of the algorithms developed using this data base.
Benson, K.; Estrada, T.; Taufer, M.; Lawrence, J.; Cochran, E.
2011-01-01
The Quake-Catcher Network (QCN) uses low-cost sensors connected to volunteer computers across the world to monitor seismic events. The location and density of these sensors' placement can impact the accuracy of the event detection. Because testing different special arrangements of new sensors could disrupt the currently active project, this would best be accomplished in a simulated environment. This paper presents an accurate and efficient framework for simulating the low cost QCN sensors and identifying their most effective locations and densities. Results presented show how our simulations are reliable tools to study diverse scenarios under different geographical and infrastructural constraints. ?? 2011 IEEE.
Sun, Li; Westerdahl, Dane; Ning, Zhi
2017-08-19
Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO₂) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO₂ electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO₂ as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO₂ analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air.
Hyperspectral Microwave Atmospheric Sounder (HyMas) - New Capability in the CoSMIR-CoSSIR Scanhead
NASA Technical Reports Server (NTRS)
Hilliard, L. M.; Racette, P. E.; Blackwell, W.; Galbraith, C.; Thompson, E.
2015-01-01
Lincoln Laboratory and NASA's Goddard Space Flight Center have teamed to re-use an existing instrument platform, the CoSMIRCoSSIR system for atmospheric sounding, to develop a new capability in hyperspectral filtering, data collection, and display. The volume of the scanhead accomodated an intermediate frequency processor(IFP), that provides the filtering and digitization of the raw data and the interoperable remote component (IRC) adapted to CoSMIR, CoSSIR, and HyMAS that stores and archives the data with time tagged calibration and navigation data.The first element of the work is the demonstration of a hyperspectral microwave receiver subsystem that was recently shown using a comprehensive simulation study to yield performance that substantially exceeds current state-of-the-art. Hyperspectral microwave sounders with 100 channels offer temperature and humidity sounding improvements similar to those obtained when infrared sensors became hyperspectral, but with the relative insensitivity to clouds that characterizes microwave sensors. Hyperspectral microwave operation is achieved using independent RF antennareceiver arrays that sample the same areavolume of the Earths surfaceatmosphere at slightly different frequencies and therefore synthesize a set of dense, finely spaced vertical weighting functions. The second, enabling element of the proposal is the development of a compact 52-channel Intermediate Frequency processor module. A principal challenge in the development of a hyperspectral microwave system is the size of the IF filter bank required for channelization. Large bandwidths are simultaneously processed, thus complicating the use of digital back-ends with associated high complexities, costs, and power requirements. Our approach involves passive filters implemented using low-temperature co-fired ceramic (LTCC) technology to achieve an ultra-compact module that can be easily integrated with existing RF front-end technology. This IF processor is universally applicable to other microwave sensing missions requiring compact IF spectrometry.The data include 52 operational channels with low IF module volume (100cm3) and mass (300g) and linearity better than 0.3 over a 330K dynamic range.
NASA Astrophysics Data System (ADS)
Antolín-Urbaneja, J. C.; Eguizabal, I.; Briz, N.; Dominguez, A.; Estensoro, P.; Secchi, A.; Varriale, A.; Di Giovanni, S.; D'Auria, S.
2013-05-01
Several techniques for detecting chemical drug precursors have been developed in the last decade. Most of them are able to identify molecules at very low concentration under lab conditions. Other commercial devices are able to detect a fixed number and type of target substances based on a single detection technique providing an absence of flexibility with respect to target compounds. The construction of compact and easy to use detection systems providing screening for a large number of compounds being able to discriminate them with low false alarm rate and high probability of detection is still an open concern. Under CUSTOM project, funded by the European Commission within the FP7, a stand-alone portable sensing device based on multiple techniques is being developed. One of these techniques is based on the LED induced fluorescence polarization to detect Ephedrine and Benzyl Methyl Keton (BMK) as a first approach. This technique is highly selective with respect to the target compounds due to the generation of properly engineered fluorescent proteins which are able to bind the target analytes, as it happens in an "immune-type reaction". This paper deals with the advances in the design, construction and validation of the LED induced fluorescence sensor to detect BMK analytes. This sensor includes an analysis module based on high performance LED and PMT detector, a fluidic system to dose suitable quantities of reagents and some printed circuit boards, all of them fixed in a small structure (167mm × 193mm × 228mm) with the capability of working as a stand-alone application.
Tongrod, Nattapong; Lokavee, Shongpun; Watthanawisuth, Natthapol; Tuantranont, Adisorn; Kerdcharoen, Teerakiat
2013-03-01
Current trends in Human-Computer Interface (HCI) have brought on a wave of new consumer devices that can track the motion of our hands. These devices have enabled more natural interfaces with computer applications. Data gloves are commonly used as input devices, equipped with sensors that detect the movements of hands and communication unit that interfaces those movements with a computer. Unfortunately, the high cost of sensor technology inevitably puts some burden to most general users. In this research, we have proposed a low-cost data glove concept based on printed polymeric sensor to make pressure and bending sensors fabricated by a consumer ink-jet printer. These sensors were realized using a conductive polymer (poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) [PEDOT:PSS]) thin film printed on glossy photo paper. Performance of these sensors can be enhanced by addition of dimethyl sulfoxide (DMSO) into the aqueous dispersion of PEDOT:PSS. The concept of surface resistance was successfully adopted for the design and fabrication of sensors. To demonstrate the printed sensors, we constructed a data glove using such sensors and developed software for real time hand tracking. Wireless networks based on low-cost Zigbee technology were used to transfer data from the glove to a computer. To our knowledge, this is the first report on low cost data glove based on paper pressure sensors. This low cost implementation of both sensors and communication network as proposed in this paper should pave the way toward a widespread implementation of data glove for real-time hand tracking applications.
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in...
Measuring PM and related air pollutants using low-cost sensors
Emerging air quality sensors may play a key role in better characterizing levels of air pollution in a variety of settings There are a wide range of low-cost (< $500 US) sensors on the market, but few have been characterized. If accurate, this new generation of inexpensive sens...
A compact lightweight Earth horizon sensor using an uncooled infrared bolometer
NASA Astrophysics Data System (ADS)
Marchese, Linda E.; Thomas, Paul; Pope, Timothy D.; Asselin, Daniel; Jerominek, Hubert
2007-06-01
A compact, lightweight Earth horizon sensor has been designed based on uncooled infrared microbolometer array technology developed at INO. The design has been optimized for use on small satellites in Low Earth Orbits. The sensor may be used either as an attitude sensor or as an atmospheric limb detector. Various configurations may be implemented for both spinning and 3-axis stabilized satellites. The core of the sensor is the microbolometer focal plane array equipped with 256 x 1 VO x thermistor pixels with a pitch of 52 μm. The optics consists of a single Zinc Selenide lens with a focal length of 39.7 mm. The system's F-number is 3.8 and the detector limited Noise Equivalent Temperature Difference is estimated to be 0.75 K at 300 K for the 14 - 16 μm wavelength range. A single-sensor configuration will have a mass of less than 300g, a volume of 125 cm 3 and a power consumption of 600 mW, making it well-suited for small satellite missions.
Compact discs as versatile cost-effective substrates for releasable nanopatterned aluminium films
NASA Astrophysics Data System (ADS)
Barrios, Carlos Angulo; Canalejas-Tejero, Víctor
2015-02-01
We demonstrate that standard polycarbonate compact disk surfaces can provide unique adhesion to Al films that is both strong enough to permit Al film nanopatterning and weak enough to allow easy nanopatterned Al film detachment using Scotch tape. Transferred Al nanohole arrays on Scotch tape exhibit excellent optical and plasmonic performance.We demonstrate that standard polycarbonate compact disk surfaces can provide unique adhesion to Al films that is both strong enough to permit Al film nanopatterning and weak enough to allow easy nanopatterned Al film detachment using Scotch tape. Transferred Al nanohole arrays on Scotch tape exhibit excellent optical and plasmonic performance. Electronic supplementary information (ESI) available: 1. Optical simulations (Fig. SI.1); 2. Optical coupling via an Al NHA on the Scotch tape (Fig. SI.2); 3. Electrostatics-based opto-mechanical cantilever (Fig. SI.3). Video 1. Transfer of the Al film nanostructured with a nanohole array from a polycarbonate CD surface onto a Scotch tape; Video 2. Opto-mechanical electrostatics-based sensor: electrical attraction. Video 3. Opto-mechanical electrostatics-based sensor: electrical repulsion. See DOI: 10.1039/c4nr06271j
A LEO Satellite Navigation Algorithm Based on GPS and Magnetometer Data
NASA Technical Reports Server (NTRS)
Deutschmann, Julie; Bar-Itzhack, Itzhack; Harman, Rick; Bauer, Frank H. (Technical Monitor)
2000-01-01
The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes.
Cennamo, Nunzio; D'Agostino, Girolamo; Donà, Alice; Dacarro, Giacomo; Pallavicini, Piersandro; Pesavento, Maria; Zeni, Luigi
2013-01-01
In this paper a refractive index sensor based on localized surface plasmon resonance (LSPR) in a Plastic Optical Fiber (POF), is presented and experimentally tested. LSPR is achieved exploiting five-branched gold nanostars (GNS) obtained using Triton X-100 in a seed-growth synthesis. They have the uncommon feature of three localized surface plasmon resonances. The strongest LSPRs fall in two ranges, one in the 600–900 nm range (LSPR 2) and the other one in the 1,100–1,600 nm range (LSPR 3), both sensible to refractive index changes. Anyway, due to the extremely strong attenuation (>102 dB/m) of the employed POF in the 1,100–1,600 nm range, only LSPR 2 will be exploited for refractive index change measurements, useful for bio-chemical sensing applications, as a proof of principle of the possibility of realizing a compact, low cost and easy-to-use GNS based device. PMID:24172284
Cennamo, Nunzio; D'Agostino, Girolamo; Donà, Alice; Dacarro, Giacomo; Pallavicini, Piersandro; Pesavento, Maria; Zeni, Luigi
2013-10-29
In this paper a refractive index sensor based on localized surface plasmon resonance (LSPR) in a Plastic Optical Fiber (POF), is presented and experimentally tested. LSPR is achieved exploiting five-branched gold nanostars (GNS) obtained using Triton X-100 in a seed-growth synthesis. They have the uncommon feature of three localized surface plasmon resonances. The strongest LSPRs fall in two ranges, one in the 600-900 nm range (LSPR 2) and the other one in the 1,100-1,600 nm range (LSPR 3), both sensible to refractive index changes. Anyway, due to the extremely strong attenuation (>10(2) dB/m) of the employed POF in the 1,100-1,600 nm range, only LSPR 2 will be exploited for refractive index change measurements, useful for bio-chemical sensing applications, as a proof of principle of the possibility of realizing a compact, low cost and easy-to-use GNS based device.
NASA Astrophysics Data System (ADS)
Mustafaev, Alexander; Rastvorova, Iuliia; Arslanova, Fatima
2017-10-01
It is generally recognized that careful implementation of ecological monitoring should be provided at hazardous production facilities continuously to protect the surrounding environment as well as health and safety of employees. However, the existing devices may not be able to control the environmental situation uninterruptedly due to their technical characteristics or measurement methods. Developed by The Mining University Plasma Research Group ultra-compact photoionization analyzer is proposed as innovative equipment which creates the basis for a new measuring approach. The general operating principle is based on the patented method of stabilization of electric parameters - CES (Collisional Electron Spectroscopy). During the operation at the atmospheric pressure, the vacuum ultraviolet (VUV) photoionization sensor measures the energy of electrons produced by means of ionization with the resonance photons whose wavelength is situated in the VUV. A special software tool was developed to obtain the second-order derivative of the I-U characteristics, taken by the VUV sensor, to construct the characteristic electrons energy spectra. The portable analyzer with a unique set of parameters such as small size (10*10*1 mm), low cost, a wide range of recognizable molecules, great measurement accuracy at the atmospheric pressure can be effectively used both for rapid testing of air pollution load and the study of noxious factors that influence oil and gas industry employees. Dr. Sci., Ph.D, Principal Scientist, Professor.
Design and experiment of spectrometer based on scanning micro-grating integrating with angle sensor
NASA Astrophysics Data System (ADS)
Biao, Luo; Wen, Zhi-yu
2014-01-01
A compact, low cost, high speed, non-destructive testing NIR (near infrared) spectrometer optical system based on MOEMS grating device is developed. The MOEMS grating works as the prismatic element and wavelength scanning element in our optical system. The MOEMS grating enables the design of compact grating spectrometers capable of acquiring full spectra using a single detector element. This MOEMS grating is driven by electromagnetic force and integrated with angle sensor which used to monitored deflection angle while the grating working. Comparing with the traditional spectral system, there is a new structure with a single detector and worked at high frequency. With the characteristics of MOEMS grating, the structure of the spectrometer system is proposed. After calculating the parameters of the optical path, ZEMAX optical software is used to simulate the system. According the ZEMAX output file of the 3D model, the prototype is designed by SolidWorks rapidly, fabricated. Designed for a wavelength range between 800 nm and 1500 nm, the spectrometer optical system features a spectral resolution of 16 nm with the volume of 97 mm × 81.7 mm × 81 mm. For the purpose of reduce modulated effect of sinusoidal rotation, spectral intensity of the different wavelength should be compensated by software method in the further. The system satisfies the demand of NIR micro-spectrometer with a single detector.
Low-cost compact MEMS scanning ladar system for robotic applications
NASA Astrophysics Data System (ADS)
Moss, Robert; Yuan, Ping; Bai, Xiaogang; Quesada, Emilio; Sudharsanan, Rengarajan; Stann, Barry L.; Dammann, John F.; Giza, Mark M.; Lawler, William B.
2012-06-01
Future robots and autonomous vehicles require compact low-cost Laser Detection and Ranging (LADAR) systems for autonomous navigation. Army Research Laboratory (ARL) had recently demonstrated a brass-board short-range eye-safe MEMS scanning LADAR system for robotic applications. Boeing Spectrolab is doing a tech-transfer (CRADA) of this system and has built a compact MEMS scanning LADAR system with additional improvements in receiver sensitivity, laser system, and data processing system. Improved system sensitivity, low-cost, miniaturization, and low power consumption are the main goals for the commercialization of this LADAR system. The receiver sensitivity has been improved by 2x using large-area InGaAs PIN detectors with low-noise amplifiers. The FPGA code has been updated to extend the range to 50 meters and detect up to 3 targets per pixel. Range accuracy has been improved through the implementation of an optical T-Zero input line. A compact commercially available erbium fiber laser operating at 1550 nm wavelength is used as a transmitter, thus reducing the size of the LADAR system considerably from the ARL brassboard system. The computer interface has been consolidated to allow image data and configuration data (configuration settings and system status) to pass through a single Ethernet port. In this presentation we will discuss the system architecture and future improvements to receiver sensitivity using avalanche photodiodes.
A miniature disposable radio (MiDR) for unattended ground sensor systems (UGSS) and munitions
NASA Astrophysics Data System (ADS)
Wells, Jeffrey S.; Wurth, Timothy J.
2004-09-01
Unattended and tactical sensors are used by the U.S. Army"s Future Combat Systems (FCS) and Objective Force Warrior (OFW) to detect and identify enemy targets on the battlefield. The radios being developed as part of the Networked Sensors for the Objective Force (NSOF) are too costly and too large to deploy in missions requiring throw-away hardware. A low-cost miniature radio is required to satisfy the communication needs for unmanned sensor and munitions systems that are deployed in a disposable manner. A low cost miniature disposable communications suite is leveraged using the commercial off-the-shelf market and employing a miniature universal frequency conversion architecture. Employing the technology of universal frequency architecture in a commercially available communication unit delivers a robust disposable transceiver that can operate at virtually any frequency. A low-cost RF communication radio has applicability in the commercial, homeland defense, military, and other government markets. Specific uses include perimeter monitoring, infrastructure defense, unattended ground sensors, tactical sensors, and border patrol. This paper describes a low-cost radio architecture to meet the requirements of throw-away radios that can be easily modified or tuned to virtually any operating frequency required for the specific mission.
A Programmable Plug & Play Sensor Interface for WSN Applications
Vera, Sergio D.; Bayo, Alberto; Medrano, Nicolás; Calvo, Belén; Celma, Santiago
2011-01-01
Cost reduction in wireless sensor networks (WSN) becomes a priority when extending their application to fields where a great number of sensors is needed, such as habitat monitoring, precision agriculture or diffuse greenhouse emission measurement. In these cases, the use of smart sensors is expensive, consequently requiring the use of low-cost sensors. The solution to convert such generic low-cost sensors into intelligent ones leads to the implementation of a versatile system with enhanced processing and storage capabilities to attain a plug and play electronic interface able to adapt to all the sensors used. This paper focuses on this issue and presents a low-voltage plug & play reprogrammable interface capable of adapting to different sensor types and achieving an optimum reading performance for every sensor. The proposed interface, which includes both electronic and software elements so that it can be easily integrated in WSN nodes, is described and experimental test results to validate its performance are given. PMID:22164118
Community Air Sensor Network CAIRSENSE Project: Lower ...
Presentation slides on the CAIRSENSE project, Atlanta field study testing low cost air sensors against FEM instruments. To be presented at the Air and Waste Management Association conference. Presentation slides on the CAIRSENSE project, Atlanta field study testing low cost air sensors against FEM instruments. To be presented at the Air and Waste Management Association conference.
Sun, Li; Westerdahl, Dane; Ning, Zhi
2017-01-01
Emerging low-cost gas sensor technologies have received increasing attention in recent years for air quality measurements due to their small size and convenient deployment. However, in the diverse applications these sensors face many technological challenges, including sensor drift over long-term deployment that cannot be easily addressed using mathematical correction algorithms or machine learning methods. This study aims to develop a novel approach to auto-correct the drift of commonly used electrochemical nitrogen dioxide (NO2) sensor with comprehensive evaluation of its application. The impact of environmental factors on the NO2 electrochemical sensor in low-ppb concentration level measurement was evaluated in laboratory and the temperature and relative humidity correction algorithm was evaluated. An automated zeroing protocol was developed and assessed using a chemical absorbent to remove NO2 as a means to perform zero correction in varying ambient conditions. The sensor system was operated in three different environments in which data were compared to a reference NO2 analyzer. The results showed that the zero-calibration protocol effectively corrected the observed drift of the sensor output. This technique offers the ability to enhance the performance of low-cost sensor based systems and these findings suggest extension of the approach to improve data quality from sensors measuring other gaseous pollutants in urban air. PMID:28825633
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-01-01
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique. PMID:27517931
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.
Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José
2016-08-10
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.
Calibration of low-cost gas sensors for an urban air quality monitoring network
NASA Astrophysics Data System (ADS)
Scott, A.; Kelley, C.; He, C.; Ghugare, P.; Lehman, A.; Benish, S.; Stratton, P.; Dickerson, R. R.; Zuidema, C.; Azdoud, Y.; Ren, X.
2017-12-01
In a warming world, environmental pollution may be exacerbated by anthropogenic activities, such as climate change and the urban heat island effect, as well as natural phenomena such as heat waves. However, monitoring air pollution at federal reference standards (approximately 1 part per billion or ppb for ambient ozone) is cost-prohibitive in heterogeneous urban areas as many expensive devices are required to fully capture a region's geo-spatial variability. Innovation in low-cost sensors provide a potential solution, yet technical challenges remain to overcome possible imprecision in the data. We present the calibrations of ozone and nitrous dioxide from a low-cost air quality monitoring device designed for the Baltimore Open Air Project. The sensors used in this study are commercially available thin film electrochemical sensors from SPEC Sensor, which are amperometric, meaning they generate current proportional to volumetric fraction of gas. The results of sensor calibrations in the laboratory and field are presented.
Lave, Matthew; Stein, Joshua; Smith, Ryan
2016-07-28
To address the lack of knowledge of local solar variability, we have developed and deployed a low-cost solar variability datalogger (SVD). While most currently used solar irradiance sensors are expensive pyranometers with high accuracy (relevant for annual energy estimates), low-cost sensors display similar precision (relevant for solar variability) as high-cost pyranometers, even if they are not as accurate. In this work, we present evaluation of various low-cost irradiance sensor types, describe the SVD, and present validation and comparison of the SVD collected data. In conclusion, the low cost and ease of use of the SVD will enable a greater understandingmore » of local solar variability, which will reduce developer and utility uncertainty about the impact of solar photovoltaic (PV) installations and thus will encourage greater penetrations of solar energy.« less
An embeddable optical strain gauge based on a buckled beam.
Du, Yang; Chen, Yizheng; Zhu, Chen; Zhuang, Yiyang; Huang, Jie
2017-11-01
We report, for the first time, a low cost, compact, and novel mechanically designed extrinsic Fabry-Perot interferometer (EFPI)-based optical fiber sensor with a strain amplification mechanism for strain measurement. The fundamental design principle includes a buckled beam with a coated gold layer, mounted on two grips. A Fabry-Perot cavity is produced between the buckled beam and the endface of a single mode fiber (SMF). A ceramic ferrule is applied for supporting and orienting the SMF. The principal sensor elements are packaged and protected by two designed metal shells. The midpoint of the buckled beam will experience a deflection vertically when the beam is subjected to a horizontally/axially compressive displacement. It has been found that the vertical deflection of the beam at midpoint can be 6-17 times larger than the horizontal/axial displacement, which forms the basis of a strain amplification mechanism. The user-configurable buckling beam geometry-based strain amplification mechanism enables the strain sensor to achieve a wide range of strain measurement sensitivities. The designed EFPI was used to monitor shrinkage of a square brick of mortar. The strain was measured during the drying/curing stage. We envision that it could be a good strain sensor to be embedded in civil materials/structures under a harsh environment for a prolonged period of time.
An embeddable optical strain gauge based on a buckled beam
NASA Astrophysics Data System (ADS)
Du, Yang; Chen, Yizheng; Zhu, Chen; Zhuang, Yiyang; Huang, Jie
2017-11-01
We report, for the first time, a low cost, compact, and novel mechanically designed extrinsic Fabry-Perot interferometer (EFPI)-based optical fiber sensor with a strain amplification mechanism for strain measurement. The fundamental design principle includes a buckled beam with a coated gold layer, mounted on two grips. A Fabry-Perot cavity is produced between the buckled beam and the endface of a single mode fiber (SMF). A ceramic ferrule is applied for supporting and orienting the SMF. The principal sensor elements are packaged and protected by two designed metal shells. The midpoint of the buckled beam will experience a deflection vertically when the beam is subjected to a horizontally/axially compressive displacement. It has been found that the vertical deflection of the beam at midpoint can be 6-17 times larger than the horizontal/axial displacement, which forms the basis of a strain amplification mechanism. The user-configurable buckling beam geometry-based strain amplification mechanism enables the strain sensor to achieve a wide range of strain measurement sensitivities. The designed EFPI was used to monitor shrinkage of a square brick of mortar. The strain was measured during the drying/curing stage. We envision that it could be a good strain sensor to be embedded in civil materials/structures under a harsh environment for a prolonged period of time.
Shaw, P E; Burn, P L
2017-11-15
The detection of explosives continues to be a pressing global challenge with many potential technologies being pursued by the scientific research community. Luminescence-based detection of explosive vapours with an organic semiconductor has attracted much interest because of its potential for detectors that have high sensitivity, compact form factor, simple operation and low-cost. Despite the abundance of literature on novel sensor materials systems there are relatively few mechanistic studies targeted towards vapour-based sensing. In this Perspective, we will review the progress that has been made in understanding the processes that control the real-time luminescence quenching of thin films by analyte vapours. These are the non-radiative quenching process by which the sensor exciton decays, the analyte-sensor intermolecular binding interaction, and the diffusion process for the analyte vapours in the film. We comment on the contributions of each of these processes towards the sensing response and, in particular, the relative roles of analyte diffusion and exciton diffusion. While the latter has been historically judged to be one of, if not the primary, causes for the high sensitivity of many conjugated polymers to nitrated vapours, recent evidence suggests that long exciton diffusion lengths are unnecessary. The implications of these results on the development of sensor materials for real-time detection are discussed.
Compact intra-cavity frequency doubled line beam green laser by a laser diode array pumped
NASA Astrophysics Data System (ADS)
Yan, Boxia; Qi, Yan; Wang, Yanwei
2016-10-01
Compact, high power, and low-cost green laser light sources are needed in projection-related applications such as digital cinema, rear-projection television, simulators, and command and control stations. We report a LD array directly pumped intracavity SHG Nd:YVO4/PPMgLN laser without lens or waveguide in this letter. A compact 3.12 W green laser was demonstrated by intra-cavity frequency doubled using a PPMgLN bulk crystal by a 19-emitter LD array pumped(single bar), the conversion efficiency from input LD array was 9.2%. A line-beam output suitable for laser projectors was generated, which has the potential to be scalable to small volumes and low costs for laser projection displays.
Compact orthogonal NMR field sensor
Gerald, II, Rex E.; Rathke, Jerome W [Homer Glen, IL
2009-02-03
A Compact Orthogonal Field Sensor for emitting two orthogonal electro-magnetic fields in a common space. More particularly, a replacement inductor for existing NMR (Nuclear Magnetic Resonance) sensors to allow for NMR imaging. The Compact Orthogonal Field Sensor has a conductive coil and a central conductor electrically connected in series. The central conductor is at least partially surrounded by the coil. The coil and central conductor are electrically or electro-magnetically connected to a device having a means for producing or inducing a current through the coil and central conductor. The Compact Orthogonal Field Sensor can be used in NMR imaging applications to determine the position and the associated NMR spectrum of a sample within the electro-magnetic field of the central conductor.
Hybrid wavefront sensor for the fast detection of wavefront disturbances.
Dong, Shihao; Haist, Tobias; Osten, Wolfgang
2012-09-01
Strongly aberrated wavefronts lead to inaccuracies and nonlinearities in holography-based modal wavefront sensing (HMWS). In this contribution, a low-resolution Shack-Hartmann sensor (LRSHS) is incorporated into HMWS via a compact holographic design to extend the dynamic range of HMWS. A static binary-phase computer-generated hologram is employed to generate the desired patterns for Shack-Hartmann sensing and HMWS. The low-order aberration modes dominating the wavefront error are first sensed with the LRSHS and corrected by the wavefront modulator. The system then switches to HMWS to obtain better sensor sensitivity and accuracy. Simulated as well as experimental results are shown for validating the proposed method.
An UGS radar with micro-Doppler capabilities for wide area persistent surveillance
NASA Astrophysics Data System (ADS)
Tahmoush, Dave; Silvious, Jerry; Clark, John
2010-04-01
Detecting humans and distinguishing them from natural fauna is an important issue in security applications to reduce false alarm rates. In particular, it is important to detect and classify people who are walking in remote locations and transmit back detections over extended periods at a low cost and with minimal maintenance. The ability to discriminate men versus animals and vehicles at long range would give a distinct sensor advantage. The reduction in false positive detections due to animals would increase the usefulness of detections, while dismount identification could reduce friendly-fire. We developed and demonstrate a compact radar technology that is scalable to a variety of ultra-lightweight and low-power platforms for wide area persistent surveillance as an unattended, unmanned, and man-portable ground sensor. The radar uses micro-Doppler processing to characterize the tracks of moving targets and to then eliminate unimportant detections due to animals or civilian activity. This paper presents the system and data on humans, vehicles, and animals at multiple angles and directions of motion, demonstrates the signal processing approach that makes the targets visually recognizable, and verifies that the UGS radar has enough micro-Doppler capability to distinguish between humans, vehicles, and animals.
Monolithic integrated optic fiber Bragg grating sensor interrogator
NASA Astrophysics Data System (ADS)
Mendoza, Edgar A.; Esterkin, Yan; Kempen, Cornelia; Sun, Songjian
2010-04-01
Fiber Bragg gratings (FBGs) are a mature sensing technology that has gained rapid acceptance in civil, aerospace, chemical and petrochemical, medicine, aviation and automotive industries. Fiber Bragg grating sensors can be use for a variety of measurements including strain, stress, vibration, acoustics, acceleration, pressure, temperature, moisture, and corrosion distributed at multiple locations within the structure using a single fiber element. The most prominent advantages of FBGs are: small size and light weight, multiple FBG transducers on a single fiber, and immunity to radio frequency interference. A major disadvantage of FBG technology is that conventional state-of-the-art fiber Bragg grating interrogation systems are typically bulky, heavy, and costly bench top instruments that are assembled from off-the-shelf fiber optic and optical components integrated with a signal electronics board into an instrument console. Based on the need for a compact FBG interrogation system, this paper describes recent progress towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-TransceiverTM) system based on multi-channel monolithic integrated optic sensor microchip technology. The integrated optic microchip technology enables the monolithic integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogators systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm small form factor (SFF) package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation.
Note: Compact and light displacement sensor for a precision measurement system in large motion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sang Heon, E-mail: shlee@andong.ac.kr
We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, amore » simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.« less
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide.
Duvall, Rachelle M; Long, Russell W; Beaver, Melinda R; Kronmiller, Keith G; Wheeler, Michael L; Szykman, James J
2016-10-13
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O₃) and nitrogen dioxide (NO₂). The performance evaluation showed that the CairClip O₃/NO₂ sensor provided a consistent measurement response to that of reference monitors (r² = 0.79 in Houston; r² = 0.72 in Denver) whereas the CairClip NO₂ sensor measurements showed no agreement to reference measurements. The CairClip O₃/NO₂ sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists.
NASA Astrophysics Data System (ADS)
Joshi, V.; Manivannan, N.; Jarry, Z.; Carmichael, J.; Vahtel, M.; Zamora, G.; Calder, C.; Simon, J.; Burge, M.; Soliz, P.
2018-02-01
Diabetic peripheral neuropathy (DPN) accounts for around 73,000 lower-limb amputations annually in the US on patients with diabetes. Early detection of DPN is critical. Current clinical methods for diagnosing DPN are subjective and effective only at later stages. Until recently, thermal cameras used for medical imaging have been expensive and hence prohibitive to be installed in primary care setting. The objective of this study is to compare results from a low-cost thermal camera with a high-end thermal camera used in screening for DPN. Thermal imaging has demonstrated changes in microvascular function that correlates with nerve function affected by DPN. The limitations for using low-cost cameras for DPN imaging are: less resolution (active pixels), frame rate, thermal sensitivity etc. We integrated two FLIR Lepton (80x60 active pixels, 50° HFOV, thermal sensitivity < 50mK) as one unit. Right and left cameras record the videos of right and left foot respectively. A compactible embedded system (raspberry pi3 model Bv1.2) is used to configure the sensors, capture and stream the video via ethernet. The resulting video has 160x120 active pixels (8 frames/second). We compared the temperature measurement of feet obtained using low-cost camera against the gold standard highend FLIR SC305. Twelve subjects (aged 35-76) were recruited. Difference in the temperature measurements between cameras was calculated for each subject and the results show that the difference between the temperature measurements of two cameras (mean difference=0.4, p-value=0.2) is not statistically significant. We conclude that the low-cost thermal camera system shows potential for use in detecting early-signs of DPN in under-served and rural clinics.
Ammonia Optical Sensing by Microring Resonators.
Passaro, Vittorio M N; Dell'Olio, Francesco; De Leonardis, Francesco
2007-11-15
A very compact (device area around 40 μm²) optical ammonia sensor based on amicroring resonator is presented in this work. Silicon-on-insulator technology is used insensor design and a dye doped polymer is adopted as sensing material. The sensor exhibitsa very good linearity and a minimum detectable refractive index shift of sensing materialas low as 8x10 -5 , with a detection limit around 4 ‰.
2009-11-04
A Nanosensor Device for Cellphone Intergration and Chemical Sensing Network. iPhone with sensor chip, data aquisition board and sampling jet.(Note 4-4-2012:High Sensitive, Low Power and Compact Nano Sensors for Trache Chemical Detection' is the winner of the Government Invention of the Year Award 2012 (winning inventors Jing Li and Myya Meyyappan, NASA/ARC, and Yijiang Lu, University of California Santa Cruz. )
The photoluminescence of a fluorescent lamp: didactic experiments on the exponential decay
NASA Astrophysics Data System (ADS)
Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano
2017-01-01
The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras, can be employed to the same aim. The experiments do not require that luminescent phosphors are hazardously extracted from the compact fluorescent lamp, that also contains mercury. We obtain lifetime measurements for specific fluorescent elements of the bulb coating, in good agreement with the known values. We also address the physical mechanisms on which fluorescence lamps are based in a simplified way, suitable for undergraduate students; and we discuss in detail the physics of the lamp switch-off by analysing the time dependent spectrum, measured through a commercial fiber-optic spectrometer. Since the experiment is not hazardous in any way, requires a simple setup up with instruments which are commonly found in educational labs, and focuses on the typical features of the exponential decay, it is suitable for being performed in the undergraduate laboratory.
Bishara, Waheb; Sikora, Uzair; Mudanyali, Onur; Su, Ting-Wei; Yaglidere, Oguzhan; Luckhart, Shirley; Ozcan, Aydogan
2011-04-07
We report a portable lensless on-chip microscope that can achieve <1 µm resolution over a wide field-of-view of ∼ 24 mm(2) without the use of any mechanical scanning. This compact on-chip microscope weighs ∼ 95 g and is based on partially coherent digital in-line holography. Multiple fiber-optic waveguides are butt-coupled to light emitting diodes, which are controlled by a low-cost micro-controller to sequentially illuminate the sample. The resulting lensfree holograms are then captured by a digital sensor-array and are rapidly processed using a pixel super-resolution algorithm to generate much higher resolution holographic images (both phase and amplitude) of the objects. This wide-field and high-resolution on-chip microscope, being compact and light-weight, would be important for global health problems such as diagnosis of infectious diseases in remote locations. Toward this end, we validate the performance of this field-portable microscope by imaging human malaria parasites (Plasmodium falciparum) in thin blood smears. Our results constitute the first-time that a lensfree on-chip microscope has successfully imaged malaria parasites.
NASA Astrophysics Data System (ADS)
Gambhir, Monika; Gupta, Shilpi; John, Priya; Mahakud, Ramakanta; Kumar, Jitendra; Prakash, Om
2018-03-01
We present development of a compact and label-free sensor based on the surface modification of copper vapor laser fabricated long period fiber gratings for detection of airborne Aspergillus niger (A. niger) fungal spores. Surface of sensors were functionalized with monoclonal glucose oxidases IgG1 for target-specific covalent binding. In process of functionalization and binding of 103 cfu/ml of pathogenic A. niger fungal spores, notable shorter wave transition in resonance wavelength from 1562.93 nm to 1555.97 nm, and significant reduction in peak loss from 61.72 dB to 57.48 dB were recorded. The implementation was cost effective and yielded instantaneous results.
Low-cost photonic sensors for carbon dioxide exchange rate measurement
NASA Astrophysics Data System (ADS)
Bieda, Marcin S.; Sobotka, Piotr; Lesiak, Piotr; Woliński, Tomasz R.
2017-10-01
Carbon dioxide (CO2) measurement has an important role in atmosphere monitoring. Usually, two types of measurements are carried out. The first one is based on gas concentration measurement while the second involves gas exchange rate measurement between earth surface and atmosphere [1]. There are several methods which allow gas concentration measurement. However, most of them require expensive instrumentation or large devices (i.e. gas chambers). In order to precisely measure either CO2 concentration or CO2 exchange rate, preferably a sensors network should be used. These sensors must have small dimensions, low power consumption, and they should be cost-effective. Therefore, this creates a great demand for a robust low-power and low-cost CO2 sensor [2,3]. As a solution, we propose a photonic sensor that can measure CO2 concentration and also can be used to measure gas exchange by using the Eddy covariance method [1].
ARBRES: Light-Weight CW/FM SAR Sensors for Small UAVs
Aguasca, Albert; Acevo-Herrera, Rene; Broquetas, Antoni; Mallorqui, Jordi J.; Fabregas, Xavier
2013-01-01
This paper describes a pair of compact CW/FM airborne SAR systems for small UAV-based operation (wingspan of 3.5 m) for low-cost testing of innovative SAR concepts. Two different SAR instruments, using the C and X bands, have been developed in the context of the ARBRES project, each of them achieving a payload weight below 5 Kg and a volume of 13.5 dm3 (sensor and controller). Every system has a dual receiving channel which allows operation in interferometric or polarimetric modes. Planar printed array antennas are used in both sensors for easy system integration and better isolation between transmitter and receiver subsystems. First experimental tests on board a 3.2 m wingspan commercial radio-controlled aircraft are presented. The SAR images of a field close to an urban area have been focused using a back-projection algorithm. Using the dual channel capability, a single pass interferogram and Digital Elevation Model (DEM) has been obtained which agrees with the scene topography. A simple Motion Compensation (MoCo) module, based on the information from an Inertial+GPS unit, has been included to compensate platform motion errors with respect to the nominal straight trajectory. PMID:23467032
ERIC Educational Resources Information Center
Hudson, Barclay M.
Descriptions of models for policy analysis in future studies are presented. Separate sections of the paper focus on the need for appropriate technologies of social science in future studies, a description of "compact policy assessment" (CPA), and a comparison of two CPA methods, Compass and Delphi. Compact policy assessment refers to any low-cost,…
Palma, A J; Ortigosa, J M; Lapresta-Fernández, A; Fernández-Ramos, M D; Carvajal, M A; Capitán-Vallvey, L F
2008-10-01
This report describes the electronics of a portable, low-cost, light-emitting diode (LED)-based photometer dedicated to one-shot optochemical sensors. Optical detection is made through a monolithic photodiode with an on-chip single-supply transimpedance amplifier that reduces some drawbacks such as leakage currents, interferences, and parasitic capacitances. The main instrument characteristics are its high light source stability and thermal correction. The former is obtained by means of the optical feedback from the LED polarization circuit, implementing a pseudo-two light beam scheme from a unique light source with a built-in beam splitter. The feedback loop has also been used to adjust the LED power in several ranges. Moreover, the low-thermal coefficient achieved (-90 ppm/degrees C) is compensated by thermal monitoring and calibration function compensation in the digital processing. The hand-held instrument directly gives the absorbance ratio used as the analytical parameter and the analyte concentration after programming the calibration function in the microcontroller. The application of this photometer for the determination of potassium and nitrate, using one-shot sensors with ionophore-based chemistries is also demonstrated, with a simple analytical methodology that shortens the analysis time, eliminating some calibrating solutions (HCl, NaOH, and buffer). Therefore, this compact instrument is suitable for real-time analyte determination and operation in the field.
Development of a Low cost Ultra tiny Line Laser Range Sensor
2016-12-01
Development of a Low-cost Ultra-tiny Line Laser Range Sensor Xiangyu Chen∗, Moju Zhao∗, Lingzhu Xiang†, Fumihito Sugai∗, Hiroaki Yaguchi∗, Kei Okada...and Masayuki Inaba∗ Abstract— To enable robotic sensing for tasks with require- ments on weight, size, and cost, we develop an ultra-tiny line laser ...view customizable using different laser lenses. The optimal measurement range of the sensor is 0.05[m] ∼ 2[m]. Higher sampling rates can be achieved
Recent advances of mid-infrared compact, field deployable sensors: principles and applications
NASA Astrophysics Data System (ADS)
Tittel, Frank; Gluszek, Aleksander; Hudzikowski, Arkadiusz; Dong, Lei; Li, Chunguang; Patimisco, Pietro; Sampaolo, Angelo; Spagnolo, Vincenzo; Wojtas, Jacek
2016-04-01
The recent development of compact interband cascade lasers(ICLs) and quantum cascade lasers (QCLs) based trace gas sensors will permit the targeting of strong fundamental rotational-vibrational transitions in the mid-infrared which are one to two orders of magnitude more intense than transitions in the overtone and combination bands in the near-infrared. This has led to the design and fabrication of mid-infrared compact, field deployable sensors for use in the petrochemical industry, environmental monitoring and atmospheric chemistry. Specifically, the spectroscopic detection and monitoring of four molecular species, methane (CH4) [1], ethane (C2H6), formaldehyde (H2CO) [2] and hydrogen sulphide (H2S) [3] will be described. CH4, C2H6 and H2CO can be detected using two detection techniques: mid-infrared tunable laser absorption spectroscopy (TDLAS) using a compact multi-pass gas cell and quartz enhanced photoacoustic spectroscopy (QEPAS). Both techniques utilize state-of-the-art mid-IR, continuous wave (CW), distributed feedback (DFB) ICLs and QCLs. TDLAS was performed with an ultra-compact 54.6m effective optical path length innovative spherical multipass gas cell capable of 435 passes between two concave mirrors separated by 12.5 cm. QEPAS used a small robust absorption detection module (ADM) which consists of a quartz tuning fork (QTF), two optical windows, gas inlet/outlet ports and a low noise frequency pre-amplifier. Wavelength modulation and second harmonic detection were employed for spectral data processing. TDLAS and QEPAS can achieve minimum detectable absorption losses in the range from 10-8 to 10-11cm-1/Hz1/2. Several recent examples of real world applications of field deployable gas sensors will be described. For example, an ICL based TDLAS sensor system is capable of detecting CH4 and C2H6 concentration levels of 1 ppb in a 1 sec. sampling time, using an ultra-compact, robust sensor architecture. H2S detection was realized with a THz QEPAS sensor system using a custom quartz tuning fork (QTF) with a new geometry and a QCL emitting at 2.913 THz [4]. Furthermore, two new approaches aimed to achieve enhanced detection sensitivities with QEPAS based sensing can be realized. The first method will make use of a compact optical power buildup cavity, which achieves significantly lower minimum detectable trace gas concentration levels of < 10 pptv. The second approach will use custom fabricated QTFs capable of improved detection sensitivity. Acknowledgements F.K. Tittel acknowledges support by the National Science Foundation (NSF) ERC MIRTHE award, the Robert Welch Foundation (Grant C-0586) and DOE ARPA-E Monitor Proram. L. Dong acknowledges support by NSF-China (Grant #s. 61275213, 61108030), J. Wojtas acknowledges support by The National Centre for Research and Development, Poland (project ID: 179616). References [1] L. Dong, C. Li, N. P. Sanchez, A. K. Gluszek, R. Griffin and F. K. Tittel;" Compact CH4 sensor system based on a continuous-wave, low power consumption, room temperature interband cascade laser", Appl. Phys Lett. 108, 011106 (2016). [2] L. Dong, Y. Yu, C. Li, S. So, and F.K. Tittel, "Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass cell" Optics Express; 23, 19821-19830 (2015). [3] V. Spagnolo, P. Patimisco, R. Pennetta, A. Sampaolo, G. Scamarcio, M. Vitiello, and F.K. Tittel, "THz Quartz-enhanced photoacoustic sensor for H2S trace gas detection", Opt. Exp. 23, 7574-7582 (2015). [4] A. Sampaolo, P. Patimisco, L. Dong , A. Geras, S, G. Scamarcio' T. Starecki, F.K Tittel, V. Spagnolo; "Quartz-Enhanced Photoacoustic Spectroscopy exploiting tuning fork overtone modes", Appl. Phys Lett. 107, 231102 (2015).
Jerrett, Michael; Donaire-Gonzalez, David; Popoola, Olalekan; Jones, Roderic; Cohen, Ronald C; Almanza, Estela; de Nazelle, Audrey; Mead, Iq; Carrasco-Turigas, Glòria; Cole-Hunter, Tom; Triguero-Mas, Margarita; Seto, Edmund; Nieuwenhuijsen, Mark
2017-10-01
Low cost, personal air pollution sensors may reduce exposure measurement errors in epidemiological investigations and contribute to citizen science initiatives. Here we assess the validity of a low cost personal air pollution sensor. Study participants were drawn from two ongoing epidemiological projects in Barcelona, Spain. Participants repeatedly wore the pollution sensor - which measured carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO 2 ). We also compared personal sensor measurements to those from more expensive instruments. Our personal sensors had moderate to high correlations with government monitors with averaging times of 1-h and 30-min epochs (r ~ 0.38-0.8) for NO and CO, but had low to moderate correlations with NO 2 (~0.04-0.67). Correlations between the personal sensors and more expensive research instruments were higher than with the government monitors. The sensors were able to detect high and low air pollution levels in agreement with expectations (e.g., high levels on or near busy roadways and lower levels in background residential areas and parks). Our findings suggest that the low cost, personal sensors have potential to reduce exposure measurement error in epidemiological studies and provide valid data for citizen science studies. Copyright © 2017 Elsevier Inc. All rights reserved.
Kupssinskü, Lucas S.; T. Guimarães, Tainá; Koste, Emilie C.; da Silva, Juarez M.; de Souza, Laís V.; Oliverio, William F. M.; Jardim, Rogélio S.; Koch, Ismael É.; de Souza, Jonas G.; Mauad, Frederico F.
2018-01-01
Water quality monitoring through remote sensing with UAVs is best conducted using multispectral sensors; however, these sensors are expensive. We aimed to predict multispectral bands from a low-cost sensor (R, G, B bands) using artificial neural networks (ANN). We studied a lake located on the campus of Unisinos University, Brazil, using a low-cost sensor mounted on a UAV. Simultaneously, we collected water samples during the UAV flight to determine total suspended solids (TSS) and dissolved organic matter (DOM). We correlated the three bands predicted with TSS and DOM. The results show that the ANN validation process predicted the three bands of the multispectral sensor using the three bands of the low-cost sensor with a low average error of 19%. The correlations with TSS and DOM resulted in R2 values of greater than 0.60, consistent with literature values. PMID:29315219
A CMOS Humidity Sensor for Passive RFID Sensing Applications
Deng, Fangming; He, Yigang; Zhang, Chaolong; Feng, Wei
2014-01-01
This paper presents a low-cost low-power CMOS humidity sensor for passive RFID sensing applications. The humidity sensing element is implemented in standard CMOS technology without any further post-processing, which results in low fabrication costs. The interface of this humidity sensor employs a PLL-based architecture transferring sensor signal processing from the voltage domain to the frequency domain. Therefore this architecture allows the use of a fully digital circuit, which can operate on ultra-low supply voltage and thus achieves low-power consumption. The proposed humidity sensor has been fabricated in the TSMC 0.18 μm CMOS process. The measurements show this humidity sensor exhibits excellent linearity and stability within the relative humidity range. The sensor interface circuit consumes only 1.05 μW at 0.5 V supply voltage and reduces it at least by an order of magnitude compared to previous designs. PMID:24841250
A CMOS humidity sensor for passive RFID sensing applications.
Deng, Fangming; He, Yigang; Zhang, Chaolong; Feng, Wei
2014-05-16
This paper presents a low-cost low-power CMOS humidity sensor for passive RFID sensing applications. The humidity sensing element is implemented in standard CMOS technology without any further post-processing, which results in low fabrication costs. The interface of this humidity sensor employs a PLL-based architecture transferring sensor signal processing from the voltage domain to the frequency domain. Therefore this architecture allows the use of a fully digital circuit, which can operate on ultra-low supply voltage and thus achieves low-power consumption. The proposed humidity sensor has been fabricated in the TSMC 0.18 μm CMOS process. The measurements show this humidity sensor exhibits excellent linearity and stability within the relative humidity range. The sensor interface circuit consumes only 1.05 µW at 0.5 V supply voltage and reduces it at least by an order of magnitude compared to previous designs.
Low-cost failure sensor design and development for water pipeline distribution systems.
Khan, K; Widdop, P D; Day, A J; Wood, A S; Mounce, S R; Machell, J
2002-01-01
This paper describes the design and development of a new sensor which is low cost to manufacture and install and is reliable in operation with sufficient accuracy, resolution and repeatability for use in newly developed systems for pipeline monitoring and leakage detection. To provide an appropriate signal, the concept of a "failure" sensor is introduced, in which the output is not necessarily proportional to the input, but is unmistakably affected when an unusual event occurs. The design of this failure sensor is based on the water opacity which can be indicative of an unusual event in a water distribution network. The laboratory work and field trials necessary to design and prove out this type of failure sensor are described here. It is concluded that a low-cost failure sensor of this type has good potential for use in a comprehensive water monitoring and management system based on Artificial Neural Networks (ANN).
NASA Astrophysics Data System (ADS)
Chetty, S.; Field, L. A.
2014-12-01
SWIMS III, is a low cost, autonomous sensor data gathering platform developed specifically for extreme/harsh cold environments. Arctic ocean's continuing decrease of summer-time ice is related to rapidly diminishing multi-year ice due to the effects of climate change. Ice911 Research aims to develop environmentally inert materials that when deployed will increase the albedo, enabling the formation and/preservation of multi-year ice. SWIMS III's sophisticated autonomous sensors are designed to measure the albedo, weather, water temperature and other environmental parameters. This platform uses low cost, high accuracy/precision sensors, extreme environment command and data handling computer system using satellite and terrestrial wireless solution. The system also incorporates tilt sensors and sonar based ice thickness sensors. The system is light weight and can be deployed by hand by a single person. This presentation covers the technical, and design challenges in developing and deploying these platforms.
NASA Astrophysics Data System (ADS)
Ginzburg, D.; Knafo, Y.; Manor, A.; Seif, R.; Ghelman, M.; Ellenbogen, M.; Pushkarsky, V.; Ifergan, Y.; Semyonov, N.; Wengrowicz, U.; Mazor, T.; Kadmon, Y.; Cohen, Y.; Osovizky, A.
2015-06-01
There is a need to develop new personal radiation detector (PRD) technologies that can be mass produced. On August 2013, DARPA released a request for information (RFI) seeking innovative radiation detection technologies. In addition, on December 2013, a Broad Agency Announcement (BAA) for the SIGMA program was released. The RFI requirements focused on a sensor that should possess three main properties: low cost, high compactness and radioisotope identification capabilities. The identification performances should facilitate the detection of a hidden threat, ranging from special nuclear materials (SNM) to commonly used radiological sources. Subsequently, the BAA presented the specific requirements at an instrument level and provided a comparison between the current market status (state-of-the-art) and the SIGMA program objectives. This work presents an optional alternative for both the detection technology (sensor with communication output and without user interface) for DARPA's initial RFI and for the PRD required by the SIGMA program. A broad discussion is dedicated to the method proposed to fulfill the program objectives and to the selected alternative that is based on the PDS-GO design and technology. The PDS-GO is the first commercially available PRD that is based on a scintillation crystal optically coupled with a silicon photomultiplier (SiPM), a solid-state light sensor. This work presents the current performance of the instrument and possible future upgrades based on recent technological improvements in the SiPM design. The approach of utilizing the SiPM with a commonly available CsI(Tl) crystal is the key for achieving the program objectives. This approach provides the appropriate performance, low cost, mass production and small dimensions; however, it requires a creative approach to overcome the obstacles of the solid-state detector dark current (noise) and gain stabilization over a wide temperature range. Based on the presented results, we presume that the proposed approach of SiPM, with pixel size of 35 μm, coupled to a scintillation material (for gamma and neutron detection) ensures the availability and low cost of the key components. Furthermore, automated manufacturing process enables mass production, thereby fulfilling the SIGMA program requirements, both as a sensor (assimilated with mobile device) and as a full detection device.
Design and build a compact Raman sensor for identification of chemical composition
NASA Astrophysics Data System (ADS)
Garcia, Christopher S.; Abedin, M. Nurul; Ismail, Syed; Sharma, Shiv K.; Misra, Anupam K.; Sandford, Stephen P.; Elsayed-Ali, Hani
2008-04-01
A compact remote Raman sensor system was developed at NASA Langley Research Center. This sensor is an improvement over the previously reported system, which consisted of a 532 nm pulsed laser, a 4-inch telescope, a spectrograph, and an intensified CCD camera. One of the attractive features of the previous system was its portability, thereby making it suitable for applications such as planetary surface explorations, homeland security and defense applications where a compact portable instrument is important. The new system was made more compact by replacing bulky components with smaller and lighter components. The new compact system uses a smaller spectrograph measuring 9 x 4 x 4 in. and a smaller intensified CCD camera measuring 5 in. long and 2 in. in diameter. The previous system was used to obtain the Raman spectra of several materials that are important to defense and security applications. Furthermore, the new compact Raman sensor system is used to obtain the Raman spectra of a diverse set of materials to demonstrate the sensor system's potential use in the identification of unknown materials.
Design and Build a Compact Raman Sensor for Identification of Chemical Composition
NASA Technical Reports Server (NTRS)
Garcia, Christopher S.; Abedin, M. Nurul; Ismail, Syed; Sharma, Shiv K.; Misra, Anupam K.; Sandford, Stephen P.; Elsayed-Ali, Hani
2008-01-01
A compact remote Raman sensor system was developed at NASA Langley Research Center. This sensor is an improvement over the previously reported system, which consisted of a 532 nm pulsed laser, a 4-inch telescope, a spectrograph, and an intensified charge-coupled devices (CCD) camera. One of the attractive features of the previous system was its portability, thereby making it suitable for applications such as planetary surface explorations, homeland security and defense applications where a compact portable instrument is important. The new system was made more compact by replacing bulky components with smaller and lighter components. The new compact system uses a smaller spectrograph measuring 9 x 4 x 4 in. and a smaller intensified CCD camera measuring 5 in. long and 2 in. in diameter. The previous system was used to obtain the Raman spectra of several materials that are important to defense and security applications. Furthermore, the new compact Raman sensor system is used to obtain the Raman spectra of a diverse set of materials to demonstrate the sensor system's potential use in the identification of unknown materials.
Commercial Motion Sensor Based Low-Cost and Convenient Interactive Treadmill.
Kim, Jonghyun; Gravunder, Andrew; Park, Hyung-Soon
2015-09-17
Interactive treadmills were developed to improve the simulation of overground walking when compared to conventional treadmills. However, currently available interactive treadmills are expensive and inconvenient, which limits their use. We propose a low-cost and convenient version of the interactive treadmill that does not require expensive equipment and a complicated setup. As a substitute for high-cost sensors, such as motion capture systems, a low-cost motion sensor was used to recognize the subject's intention for speed changing. Moreover, the sensor enables the subject to make a convenient and safe stop using gesture recognition. For further cost reduction, the novel interactive treadmill was based on an inexpensive treadmill platform and a novel high-level speed control scheme was applied to maximize performance for simulating overground walking. Pilot tests with ten healthy subjects were conducted and results demonstrated that the proposed treadmill achieves similar performance to a typical, costly, interactive treadmill that contains a motion capture system and an instrumented treadmill, while providing a convenient and safe method for stopping.
Design and Field Test of a WSN Platform Prototype for Long-Term Environmental Monitoring
Lazarescu, Mihai T.
2015-01-01
Long-term wildfire monitoring using distributed in situ temperature sensors is an accurate, yet demanding environmental monitoring application, which requires long-life, low-maintenance, low-cost sensors and a simple, fast, error-proof deployment procedure. We present in this paper the most important design considerations and optimizations of all elements of a low-cost WSN platform prototype for long-term, low-maintenance pervasive wildfire monitoring, its preparation for a nearly three-month field test, the analysis of the causes of failure during the test and the lessons learned for platform improvement. The main components of the total cost of the platform (nodes, deployment and maintenance) are carefully analyzed and optimized for this application. The gateways are designed to operate with resources that are generally used for sensor nodes, while the requirements and cost of the sensor nodes are significantly lower. We define and test in simulation and in the field experiment a simple, but effective communication protocol for this application. It helps to lower the cost of the nodes and field deployment procedure, while extending the theoretical lifetime of the sensor nodes to over 16 years on a single 1 Ah lithium battery. PMID:25912349
NASA Astrophysics Data System (ADS)
Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.
2016-12-01
In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.
Low Cost Sensor Calibration Options
Low-cost sensors ($1 D0-500) represent a unique class of air monitoring devices that may provide for more ubiquitous pollutant monitoring. They vary widely in design and measure pollutants, ranging from ozone, particulate matter, to volatile organic compounds. Many of these senso...
Cheadle, Lucy; Deanes, Lauren; Sadighi, Kira; Gordon Casey, Joanna; Collier-Oxandale, Ashley; Hannigan, Michael
2017-09-10
Recent advances in air pollution sensors have led to a new wave of low-cost measurement systems that can be deployed in dense networks to capture small-scale spatio-temporal variations in ozone, a pollutant known to cause negative human health impacts. This study deployed a network of seven low-cost ozone metal oxide sensor systems (UPods) in both an open space and an urban location in Boulder, Colorado during June and July of 2015, to quantify ozone variations on spatial scales ranging from 12 m between UPods to 6.7 km between open space and urban measurement sites with a measurement uncertainty of ~5 ppb. The results showed spatial variability of ozone at both deployment sites, with the largest differences between UPod measurements occurring during the afternoons. The peak median hourly difference between UPods was 6 ppb at 1:00 p.m. at the open space site, and 11 ppb at 4:00 p.m. at the urban site. Overall, the urban ozone measurements were higher than in the open space measurements. This study evaluates the effectiveness of using low-cost sensors to capture microscale spatial and temporal variation of ozone; additionally, it highlights the importance of field calibrations and measurement uncertainty quantification when deploying low-cost sensors.
Low-cost and high-resolution interrogation scheme for LPG-based temperature sensor
NASA Astrophysics Data System (ADS)
Venkata Reddy, M.; Srimannarayana, K.; Venkatappa Rao, T.; Vengal Rao, P.
2015-09-01
A low-cost and high-resolution interrogation scheme for a long-period fiber grating (LPG) temperature sensor with adjustable temperature range has been designed, developed and tested. In general LPGs are widely used as optical sensors and can be used as optical edge filters to interrogate the wavelength encoded signal from sensors such as fiber Bragg grating (FBG) by converting it into intensity modulated signal. But the interrogation of LPG sensors using FBG is a bit novel and it is to be studied experimentally. The sensor works based on measurement of shift in attenuation band of LPG corresponding to the applied temperature. The wavelength shift of LPG attenuation band is monitored using an optical spectrum analyser (OSA). Further the bulk and expensive OSA is replaced with a low-cost interrogation system that employ an FBG, photodiode and a transimpedance amplifier (TIA). The designed interrogation scheme makes the system low-cost, fast in response, and also enhances its resolution up to 0.1°C. The measurable temperature range using the proposed scheme is limited to 120 °C. However this range can be shifted within 15-450 °C by means of adjusting the Bragg wavelength of FBG.
Low power sensor network for wireless condition monitoring
NASA Astrophysics Data System (ADS)
Richter, Ch.; Frankenstein, B.; Schubert, L.; Weihnacht, B.; Friedmann, H.; Ebert, C.
2009-03-01
For comprehensive fatigue tests and surveillance of large scale structures, a vibration monitoring system working in the Hz and sub Hz frequency range was realized and tested. The system is based on a wireless sensor network and focuses especially on the realization of a low power measurement, signal processing and communication. Regarding the development, we met the challenge of synchronizing the wireless connected sensor nodes with sufficient accuracy. The sensor nodes ware realized by compact, sensor near signal processing structures containing components for analog preprocessing of acoustic signals, their digitization, algorithms for data reduction and network communication. The core component is a digital micro controller which performs the basic algorithms necessary for the data acquisition synchronization and the filtering. As a first application, the system was installed in a rotor blade of a wind power turbine in order to monitor the Eigen modes over a longer period of time. Currently the sensor nodes are battery powered.
A Novel Instrument and Methodology for the In-Situ Measurement of the Stress in Thin Films
NASA Technical Reports Server (NTRS)
Broadway, David M.; Omokanwaye, Mayowa O.; Ramsey, Brian D.
2014-01-01
We introduce a novel methodology for the in-situ measurement of mechanical stress during thin film growth utilizing a highly sensitive non-contact variation of the classic spherometer. By exploiting the known spherical deformation of the substrate the value of the stress induced curvature is inferred by measurement of only one point on the substrate's surface-the sagittal. From the known curvature the stress can be calculated using the well-known Stoney equation. Based on this methodology, a stress sensor has been designed which is simple, highly sensitive, compact, and low cost. As a result of its compact nature, the sensor can be mounted in any orientation to accommodate a given deposition geometry without the need for extensive modification to an already existing deposition system. The technique employs the use of a double side polished substrate that offers good specular reflectivity and is isotropic in its mechanical properties, such as <111> oriented crystalline silicon or amorphous soda lime glass, for example. The measurement of the displacement of the uncoated side during deposition is performed with a high resolution (i.e. 5nm), commercially available, inexpensive, fiber optic sensor which can be used in both high vacuum and high temperature environments (i.e. 10(exp-7) Torr and 480oC, respectively). A key attribute of this instrument lies in its potential to achieve sensitivity that rivals other measurement techniques such as the micro cantilever method but, due to the comparatively larger substrate area, offers a more robust and practical alternative for subsequent measurement of additional characteristics of the film that can might be correlated to film stress. We present measurement results of nickel films deposited by magnetron sputtering which show good qualitative agreement to the know behavior of polycrystalline films previously reported by Hoffman.
Active Self-Testing Noise Measurement Sensors for Large-Scale Environmental Sensor Networks
Domínguez, Federico; Cuong, Nguyen The; Reinoso, Felipe; Touhafi, Abdellah; Steenhaut, Kris
2013-01-01
Large-scale noise pollution sensor networks consist of hundreds of spatially distributed microphones that measure environmental noise. These networks provide historical and real-time environmental data to citizens and decision makers and are therefore a key technology to steer environmental policy. However, the high cost of certified environmental microphone sensors render large-scale environmental networks prohibitively expensive. Several environmental network projects have started using off-the-shelf low-cost microphone sensors to reduce their costs, but these sensors have higher failure rates and produce lower quality data. To offset this disadvantage, we developed a low-cost noise sensor that actively checks its condition and indirectly the integrity of the data it produces. The main design concept is to embed a 13 mm speaker in the noise sensor casing and, by regularly scheduling a frequency sweep, estimate the evolution of the microphone's frequency response over time. This paper presents our noise sensor's hardware and software design together with the results of a test deployment in a large-scale environmental network in Belgium. Our middle-range-value sensor (around €50) effectively detected all experienced malfunctions, in laboratory tests and outdoor deployments, with a few false positives. Future improvements could further lower the cost of our sensor below €10. PMID:24351634
Fabrication of Low Cost Surface Acoustic Wave Sensors Using Direct Printing by Aerosol Inkjet
Morales-Rodriguez, Marissa E.; Joshi, Pooran C.; Humphries, James R.; ...
2018-04-09
Advancements in additive manufacturing techniques, printed electronics, and nanomaterials have made it possible for the cost-effective fabrication of sensors and systems. Low-cost sensors for continuous and real time monitoring of physical and chemical parameters will directly impact the energy-efficiency, safety, and manufacturing challenges of diverse technology sectors. In this paper, we present the design, printing, and characterization of a two-port surface acoustic wave (SAW) integrated on LiNbO 3 substrate. The aerosol jet printer was used for direct-writing of interdigitated transducers for SAW devices with center frequency in the range of 40-87 MHz. In conclusion, the linear response of a temperaturemore » sensor based on the SAW design shows promise for direct-writing of environmental sensors on low-temperature substrates.« less
Fabrication of Low Cost Surface Acoustic Wave Sensors Using Direct Printing by Aerosol Inkjet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morales-Rodriguez, Marissa E.; Joshi, Pooran C.; Humphries, James R.
Advancements in additive manufacturing techniques, printed electronics, and nanomaterials have made it possible for the cost-effective fabrication of sensors and systems. Low-cost sensors for continuous and real time monitoring of physical and chemical parameters will directly impact the energy-efficiency, safety, and manufacturing challenges of diverse technology sectors. In this paper, we present the design, printing, and characterization of a two-port surface acoustic wave (SAW) integrated on LiNbO 3 substrate. The aerosol jet printer was used for direct-writing of interdigitated transducers for SAW devices with center frequency in the range of 40-87 MHz. In conclusion, the linear response of a temperaturemore » sensor based on the SAW design shows promise for direct-writing of environmental sensors on low-temperature substrates.« less
Potential of Sub-GHz Wireless for Future IoT Wearables and Design of Compact 915 MHz Antenna
Di Serio, Adolfo; Barton, John; Rodencal, Matthew; Dunlop, Gary; O’Flynn, Brendan
2017-01-01
Internet of Things (IoT) technology is rapidly emerging in medical applications as it offers the possibility of lower-cost personalized healthcare monitoring. At the present time, the 2.45 GHz band is in widespread use for these applications but in this paper, the authors investigate the potential of the 915 MHz ISM band in implementing future, wearable IoT devices. The target sensor is a wrist-worn wireless heart rate and arterial oxygen saturation (SpO2) monitor with the goal of providing efficient wireless functionality and long battery lifetime using a commercial Sub-GHz low-power radio transceiver. A detailed analysis of current consumption for various wireless protocols is also presented and analyzed. A novel 915 MHz antenna design of compact size is reported that has good resilience to detuning by the human body. The antenna also incorporates a matching network to meet the challenging bandwidth requirements and is fabricated using standard, low-cost FR-4 material. Full-Wave EM simulations are presented for the antenna placed in both free-space and on-body cases. A prototype antenna is demonstrated and has dimensions of 44 mm × 28 mm × 1.6 mm. The measured results at 915 MHz show a 10 dB return loss bandwidth of 55 MHz, a peak realized gain of −2.37 dBi in free-space and −6.1 dBi on-body. The paper concludes by highlighting the potential benefits of 915 MHz operation for future IoT devices. PMID:29271941
Potential of Sub-GHz Wireless for Future IoT Wearables and Design of Compact 915 MHz Antenna.
Di Serio, Adolfo; Buckley, John; Barton, John; Newberry, Robert; Rodencal, Matthew; Dunlop, Gary; O'Flynn, Brendan
2017-12-22
Internet of Things (IoT) technology is rapidly emerging in medical applications as it offers the possibility of lower-cost personalized healthcare monitoring. At the present time, the 2.45 GHz band is in widespread use for these applications but in this paper, the authors investigate the potential of the 915 MHz ISM band in implementing future, wearable IoT devices. The target sensor is a wrist-worn wireless heart rate and arterial oxygen saturation (SpO2) monitor with the goal of providing efficient wireless functionality and long battery lifetime using a commercial Sub-GHz low-power radio transceiver. A detailed analysis of current consumption for various wireless protocols is also presented and analyzed. A novel 915 MHz antenna design of compact size is reported that has good resilience to detuning by the human body. The antenna also incorporates a matching network to meet the challenging bandwidth requirements and is fabricated using standard, low-cost FR-4 material. Full-Wave EM simulations are presented for the antenna placed in both free-space and on-body cases. A prototype antenna is demonstrated and has dimensions of 44 mm × 28 mm × 1.6 mm. The measured results at 915 MHz show a 10 dB return loss bandwidth of 55 MHz, a peak realized gain of - 2.37 dBi in free-space and - 6.1 dBi on-body. The paper concludes by highlighting the potential benefits of 915 MHz operation for future IoT devices.
Performance comparison of single and dual-excitation-wavelength resonance-Raman explosives detectors
NASA Astrophysics Data System (ADS)
Yellampalle, Balakishore; Martin, Robert; Witt, Kenneth; McCormick, William; Wu, Hai-Shan; Sluch, Mikhail; Ice, Robert; Lemoff, Brian
2017-05-01
Deep-ultraviolet Raman spectroscopy is a very useful approach for standoff detection of explosive traces. Using two simultaneous excitation wavelengths improves the specificity and sensitivity to standoff explosive detection. The High Technology Foundation developed a highly compact prototype of resonance Raman explosives detector. In this work, we discuss the relative performance of a dual-excitation sensor compared to a single-excitation sensor. We present trade space analysis comparing three representative Raman systems with similar size, weight, and power. The analysis takes into account, cost, spectral resolution, detection/identification time and the overall system benefit.
Mudanyali, Onur; Tseng, Derek; Oh, Chulwoo; Isikman, Serhan O; Sencan, Ikbal; Bishara, Waheb; Oztoprak, Cetin; Seo, Sungkyu; Khademhosseini, Bahar; Ozcan, Aydogan
2010-06-07
Despite the rapid progress in optical imaging, most of the advanced microscopy modalities still require complex and costly set-ups that unfortunately limit their use beyond well equipped laboratories. In the meantime, microscopy in resource-limited settings has requirements significantly different from those encountered in advanced laboratories, and such imaging devices should be cost-effective, compact, light-weight and appropriately accurate and simple to be usable by minimally trained personnel. Furthermore, these portable microscopes should ideally be digitally integrated as part of a telemedicine network that connects various mobile health-care providers to a central laboratory or hospital. Toward this end, here we demonstrate a lensless on-chip microscope weighing approximately 46 grams with dimensions smaller than 4.2 cm x 4.2 cm x 5.8 cm that achieves sub-cellular resolution over a large field of view of approximately 24 mm(2). This compact and light-weight microscope is based on digital in-line holography and does not need any lenses, bulky optical/mechanical components or coherent sources such as lasers. Instead, it utilizes a simple light-emitting-diode (LED) and a compact opto-electronic sensor-array to record lensless holograms of the objects, which then permits rapid digital reconstruction of regular transmission or differential interference contrast (DIC) images of the objects. Because this lensless incoherent holographic microscope has orders-of-magnitude improved light collection efficiency and is very robust to mechanical misalignments it may offer a cost-effective tool especially for telemedicine applications involving various global health problems in resource limited settings.
Cooperative Mission Concepts Using Biomorphic Explorers
NASA Technical Reports Server (NTRS)
Thakoor, S.; Miralles, C.; Martin, T.; Kahn, R.; Zurek, R.
2000-01-01
Inspired by the immense variety of naturally curious explorers (insects, animals, and birds), their wellintegrated biological sensor-processor suites, efficiently packaged in compact but highly dexterous forms, and their complex, intriguing, cooperative behavior, this paper focuses on "Biomorphic Explorers", their defination/classification, their designs, and presents planetary exploration scenarios based on the designs. Judicious blend of bio-inspired concepts and recent advances in micro-air vehicles, microsensors, microinstruments, MEMS, and microprocessors clearly suggests that the time of small, dedicated, low cost explorers that capture some of the key features of biological systems has arrived. Just as even small insects like ants, termites, honey bees etc working cooperatively in colonies can achieve big tasks, the biomorphic explorers hold the potential for obtaining science in-accessible by current large singular exploration platforms.
Compact and low-cost THz QTDS system.
Probst, Thorsten; Rehn, Arno; Koch, Martin
2015-08-24
We present a terahertz quasi time domain spectroscopy (QTDS) system setup which is improved regarding cost and compactness. The diode laser is mounted directly onto the optical delay line, making the optical setup more compact. The system is operated using a Raspberry Pi and an additional sound card. This combination replaces the desktop/laptop computer, the lock-in-amplifier, the stage controller and the signal generator. We examined not only a commercially available stepper motor driven delay line, but also the repurposed internal mechanics from a DVD drive. We characterize the performance of the new system concept.
A low cost thermal infrared hyperspectral imager for small satellites
NASA Astrophysics Data System (ADS)
Crites, S. T.; Lucey, P. G.; Wright, R.; Garbeil, H.; Horton, K. A.
2011-06-01
The traditional model for space-based earth observations involves long mission times, high cost, and long development time. Because of the significant time and monetary investment required, riskier instrument development missions or those with very specific scientific goals are unlikely to successfully obtain funding. However, a niche for earth observations exploiting new technologies in focused, short lifetime missions is opening with the growth of the small satellite market and launch opportunities for these satellites. These low-cost, short-lived missions provide an experimental platform for testing new sensor technologies that may transition to larger, more long-lived platforms. The low costs and short lifetimes also increase acceptable risk to sensors, enabling large decreases in cost using commercial off the shelf (COTS) parts and allowing early-career scientists and engineers to gain experience with these projects. We are building a low-cost long-wave infrared spectral sensor, funded by the NASA Experimental Project to Stimulate Competitive Research program (EPSCOR), to demonstrate the ways in which a university's scientific and instrument development programs can fit into this niche. The sensor is a low-mass, power efficient thermal hyperspectral imager with electronics contained in a pressure vessel to enable the use of COTS electronics, and will be compatible with small satellite platforms. The sensor, called Thermal Hyperspectral Imager (THI), is based on a Sagnac interferometer and uses an uncooled 320x256 microbolometer array. The sensor will collect calibrated radiance data at long-wave infrared (LWIR, 8-14 microns) wavelengths in 230-meter pixels with 20 wavenumber spectral resolution from a 400-km orbit.
The fusion of satellite and UAV data: simulation of high spatial resolution band
NASA Astrophysics Data System (ADS)
Jenerowicz, Agnieszka; Siok, Katarzyna; Woroszkiewicz, Malgorzata; Orych, Agata
2017-10-01
Remote sensing techniques used in the precision agriculture and farming that apply imagery data obtained with sensors mounted on UAV platforms became more popular in the last few years due to the availability of low- cost UAV platforms and low- cost sensors. Data obtained from low altitudes with low- cost sensors can be characterised by high spatial and radiometric resolution but quite low spectral resolution, therefore the application of imagery data obtained with such technology is quite limited and can be used only for the basic land cover classification. To enrich the spectral resolution of imagery data acquired with low- cost sensors from low altitudes, the authors proposed the fusion of RGB data obtained with UAV platform with multispectral satellite imagery. The fusion is based on the pansharpening process, that aims to integrate the spatial details of the high-resolution panchromatic image with the spectral information of lower resolution multispectral or hyperspectral imagery to obtain multispectral or hyperspectral images with high spatial resolution. The key of pansharpening is to properly estimate the missing spatial details of multispectral images while preserving their spectral properties. In the research, the authors presented the fusion of RGB images (with high spatial resolution) obtained with sensors mounted on low- cost UAV platforms and multispectral satellite imagery with satellite sensors, i.e. Landsat 8 OLI. To perform the fusion of UAV data with satellite imagery, the simulation of the panchromatic bands from RGB data based on the spectral channels linear combination, was conducted. Next, for simulated bands and multispectral satellite images, the Gram-Schmidt pansharpening method was applied. As a result of the fusion, the authors obtained several multispectral images with very high spatial resolution and then analysed the spatial and spectral accuracies of processed images.
Carbon Nanotube-Based Chemiresistive Sensors
Tang, Ruixian; Shi, Yongji; Hou, Zhongyu; Wei, Liangming
2017-01-01
The development of simple and low-cost chemical sensors is critically important for improving human life. Many types of chemical sensors have been developed. Among them, the chemiresistive sensors receive particular attention because of their simple structure, the ease of high precise measurement and the low cost. This review mainly focuses on carbon nanotube (CNT)-based chemiresistive sensors. We first describe the properties of CNTs and the structure of CNT chemiresistive sensors. Next, the sensing mechanism and the performance parameters of the sensors are discussed. Then, we detail the status of the CNT chemiresistive sensors for detection of different analytes. Lastly, we put forward the remaining challenges for CNT chemiresistive sensors and outlook the possible opportunity for CNT chemiresistive sensors in the future. PMID:28420195
Carbon Nanotube-Based Chemiresistive Sensors.
Tang, Ruixian; Shi, Yongji; Hou, Zhongyu; Wei, Liangming
2017-04-18
The development of simple and low-cost chemical sensors is critically important for improving human life. Many types of chemical sensors have been developed. Among them, the chemiresistive sensors receive particular attention because of their simple structure, the ease of high precise measurement and the low cost. This review mainly focuses on carbon nanotube (CNT)-based chemiresistive sensors. We first describe the properties of CNTs and the structure of CNT chemiresistive sensors. Next, the sensing mechanism and the performance parameters of the sensors are discussed. Then, we detail the status of the CNT chemiresistive sensors for detection of different analytes. Lastly, we put forward the remaining challenges for CNT chemiresistive sensors and outlook the possible opportunity for CNT chemiresistive sensors in the future.
NEET Micro-Pocket Fission Detector. Final Project report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unruh, T.; Rempe, Joy; McGregor, Douglas
2014-09-01
A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Alternative Energies and Atomic Energy Commission, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), is funded by the Nuclear Energy Enabling Technologies (NEET) program to develop and test Micro-Pocket Fission Detectors (MPFDs), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package. When deployed, these sensors will significantly advance flux detection capabilities for irradiation tests in US Material Test Reactors (MTRs). Ultimately, evaluations may lead to a more compact, more accurate, andmore » longer lifetime flux sensor for critical mock-ups, and high performance reactors, allowing several Department of Energy Office of Nuclear Energy (DOE-NE) programs to obtain higher accuracy/higher resolution data from irradiation tests of candidate new fuels and materials. Specifically, deployment of MPFDs will address several challenges faced in irradiations performed at MTRs: Current fission chamber technologies do not offer the ability to measure fast flux, thermal flux and temperature within a single compact probe; MPFDs offer this option. MPFD construction is very different than current fission chamber construction; the use of high temperature materials allow MPFDs to be specifically tailored to survive harsh conditions encountered in-core of high performance MTRs. The higher accuracy, high fidelity data available from the compact MPFD will significantly enhance efforts to validate new high-fidelity reactor physics codes and new multi-scale, multi-physics codes. MPFDs can be built with variable sensitivities to survive the lifetime of an experiment or fuel assembly in some MTRs, allowing for more efficient and cost effective power monitoring. The small size of the MPFDs allows multiple sensors to be deployed, offering the potential to accurately measure the flux and temperature profiles in the reactor. This report summarizes the status at the end of year two of this three year project. As documented in this report, all planned accomplishments for developing this unique new, compact, multipurpose sensor have been completed.« less
Developments toward a Low-Cost Approach for Long-Term, Unattended Vapor Intrusion Monitoring
Tolley, William K.
2014-01-01
There are over 450,000 sites contaminated by chemicals in the US. This large number of contaminated sites and the speed of subsurface migration of chemicals pose considerable risk to nearby residences and commercial buildings. The high costs for monitoring around these site stem from the labor involved in placing and replacing the passive sorbent vapor samplers and the resultant laboratory analysis. This monitoring produces sparse data sets that do not track temporal changes well. To substantially reduce costs and better track exposures, less costly, unattended systems for monitoring soil gases and vapor intrusion into homes and businesses are desirable to aid in the remediation of contaminated sites. This paper describes progress toward the development of an inexpensive system specifically for monitoring vapor intrusion; the system can operate repeatedly without user intervention with low detection limits (1 × 10−9, or 1 part-per-billion). Targeted analytes include chlorinated hydrocarbons (dichloroethylene, trichloroethane, trichloroethylene, and perchloroethylene) and benzene. The system consists of a trap-and-purge preconcentrator for vapor collection in conjunction with a compact gas chromatography instrument to separate individual compounds. Chemical detection is accomplished with an array of chemicapacitors and a metal-oxide semiconductor combustibles sensor. Both the preconcentrator and the chromatography column are resistively heated. All components are compatible with ambient air, which serves as the carrier gas for the gas chromatography and detectors. PMID:24903107
Low-Cost Nested-MIMO Array for Large-Scale Wireless Sensor Applications.
Zhang, Duo; Wu, Wen; Fang, Dagang; Wang, Wenqin; Cui, Can
2017-05-12
In modern communication and radar applications, large-scale sensor arrays have increasingly been used to improve the performance of a system. However, the hardware cost and circuit power consumption scale linearly with the number of sensors, which makes the whole system expensive and power-hungry. This paper presents a low-cost nested multiple-input multiple-output (MIMO) array, which is capable of providing O ( 2 N 2 ) degrees of freedom (DOF) with O ( N ) physical sensors. The sensor locations of the proposed array have closed-form expressions. Thus, the aperture size and number of DOF can be predicted as a function of the total number of sensors. Additionally, with the help of time-sequence-phase-weighting (TSPW) technology, only one receiver channel is required for sampling the signals received by all of the sensors, which is conducive to reducing the hardware cost and power consumption. Numerical simulation results demonstrate the effectiveness and superiority of the proposed array.
Low-Cost Nested-MIMO Array for Large-Scale Wireless Sensor Applications
Zhang, Duo; Wu, Wen; Fang, Dagang; Wang, Wenqin; Cui, Can
2017-01-01
In modern communication and radar applications, large-scale sensor arrays have increasingly been used to improve the performance of a system. However, the hardware cost and circuit power consumption scale linearly with the number of sensors, which makes the whole system expensive and power-hungry. This paper presents a low-cost nested multiple-input multiple-output (MIMO) array, which is capable of providing O(2N2) degrees of freedom (DOF) with O(N) physical sensors. The sensor locations of the proposed array have closed-form expressions. Thus, the aperture size and number of DOF can be predicted as a function of the total number of sensors. Additionally, with the help of time-sequence-phase-weighting (TSPW) technology, only one receiver channel is required for sampling the signals received by all of the sensors, which is conducive to reducing the hardware cost and power consumption. Numerical simulation results demonstrate the effectiveness and superiority of the proposed array. PMID:28498329
Yan, Dan; Yang, Yong; Hong, Yingping; Liang, Ting; Yao, Zong; Chen, Xiaoyong; Xiong, Jijun
2018-02-10
Low-cost wireless temperature measurement has significant value in the food industry, logistics, agriculture, portable medical equipment, intelligent wireless health monitoring, and many areas in everyday life. A wireless passive temperature sensor based on PCB (Printed Circuit Board) materials is reported in this paper. The advantages of the sensor include simple mechanical structure, convenient processing, low-cost, and easiness in integration. The temperature-sensitive structure of the sensor is a dielectric-loaded resonant cavity, consisting of the PCB substrate. The sensitive structure also integrates a patch antenna for the transmission of temperature signals. The temperature sensing mechanism of the sensor is the dielectric constant of the PCB substrate changes with temperature, which causes the resonant frequency variation of the resonator. Then the temperature can be measured by detecting the changes in the sensor's working frequency. The PCB-based wireless passive temperature sensor prototype is prepared through theoretical design, parameter analysis, software simulation, and experimental testing. The high- and low-temperature sensing performance of the sensor is tested, respectively. The resonant frequency decreases from 2.434 GHz to 2.379 GHz as the temperature increases from -40 °C to 125 °C. The fitting curve proves that the experimental data have good linearity. Three repetitive tests proved that the sensor possess well repeatability. The average sensitivity is 347.45 KHz / ℃ from repetitive measurements conducted three times. This study demonstrates the feasibility of the PCB-based wireless passive sensor, which provides a low-cost temperature sensing solution for everyday life, modern agriculture, thriving intelligent health devices, and so on, and also enriches PCB product lines and applications.
Compact surface plasmon resonance biosensor utilizing an injection-molded prism
NASA Astrophysics Data System (ADS)
Chen, How-Foo; Chen, Chih-Han; Chang, Yun-Hsiang; Chuang, Hsin-Yuan
2016-05-01
Targeting at a low cost and accessible diagnostic device in clinical practice, a compact surface plasmon resonance (SPR) biosensor with a large dynamic range in high sensitivity is designed to satisfy commercial needs in food safety, environmental bio-pollution monitoring, and fast clinical diagnosis. The core component integrates an optical coupler, a sample-loading plate, and angle-tuning reflectors is injection-molded as a free-from prism made of plastic optics. This design makes a matching-oil-free operation during operation. The disposability of this low-cost component ensures testing or diagnosis without cross contamination in bio-samples.
Testing low cost OEM CO2 sensors for outdoor ecological studies
NASA Astrophysics Data System (ADS)
Macintyre, C. M.; Risk, D. A.
2011-12-01
IR (Infrared) gas sensors are used extensively in CO2 research but price and power requirement often limits low-cost distributed sensing. In the past three years, sensors have been introduced to the industrial market at prices as low as $100 US for air-handling and automotive application. These inexpensive sensors are small in size, and have low power demand making them potentially ideal for low-cost distributed deployments. However, the sensors are only tested and calibrated for indoor use and for industrial standards and may not show their true potential for outdoor ecological studies. This poster summarizes the results of a sensor inter-comparison test, to document functionality, response time, electrical noise, precision, and accuracy, under varying moistures and temperatures broadly representative of a wide range of outdoor settings. The three selected sensors were placed in a closed loop system with a valving system using a LiCor Li-7000 as reference, controlled by a CR1000 datalogger that controlled CO2 and moisture concentrations content within the cell on the basis of LiCor readings. To achieve different temperatures, the tests were repeated at room temperature, inside a freezer (-18°C) and incubator (40°C). The tests involved repeatedly stepping the sensors from 2000 ppm CO2 to 400 ppm CO2 in 200 ppm or 400 ppm increments, at various moisture contents, and under the various temperature regimes. Vaisala 222 and 343 sensors were also part of the test group as comparators, as both are used widely in ecological research. The OEM sensors displayed good linearity, fast response time, and results comparable to Vaisala probes. In most cases the sensors performed beyond our expectations with notably less electrical noise than the Vaisala sensors and excellent power thriftiness. Some sensors showed better response to extreme moisture and temperature conditions. Provided that suitable protective embodiments were built around them, and that they are deployed in an environment suiting their tolerance limits, most of the tested sensors would be suitable as low-cost alternatives to sensors currently being sold for outdoor ecological studies.
A Novel Low-Cost, Large Curvature Bend Sensor Based on a Bowden-Cable
Jeong, Useok; Cho, Kyu-Jin
2016-01-01
Bend sensors have been developed based on conductive ink, optical fiber, and electronic textiles. Each type has advantages and disadvantages in terms of performance, ease of use, and cost. This study proposes a new and low-cost bend sensor that can measure a wide range of accumulated bend angles with large curvatures. This bend sensor utilizes a Bowden-cable, which consists of a coil sheath and an inner wire. Displacement changes of the Bowden-cable’s inner wire, when the shape of the sheath changes, have been considered to be a position error in previous studies. However, this study takes advantage of this position error to detect the bend angle of the sheath. The bend angle of the sensor can be calculated from the displacement measurement of the sensing wire using a Hall-effect sensor or a potentiometer. Simulations and experiments have shown that the accumulated bend angle of the sensor is linearly related to the sensor signal, with an R-square value up to 0.9969 and a root mean square error of 2% of the full sensing range. The proposed sensor is not affected by a bend curvature of up to 80.0 m−1, unlike previous bend sensors. The proposed sensor is expected to be useful for various applications, including motion capture devices, wearable robots, surgical devices, or generally any device that requires an affordable and low-cost bend sensor. PMID:27347959
Low-cost scalable quartz crystal microbalance array for environmental sensing
NASA Astrophysics Data System (ADS)
Muckley, Eric S.; Anazagasty, Cristain; Jacobs, Christopher B.; Hianik, Tibor; Ivanov, Ilia N.
2016-09-01
Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution ( 1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide
Duvall, Rachelle M.; Long, Russell W.; Beaver, Melinda R.; Kronmiller, Keith G.; Wheeler, Michael L.; Szykman, James J.
2016-01-01
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O3) and nitrogen dioxide (NO2). The performance evaluation showed that the CairClip O3/NO2 sensor provided a consistent measurement response to that of reference monitors (r2 = 0.79 in Houston; r2 = 0.72 in Denver) whereas the CairClip NO2 sensor measurements showed no agreement to reference measurements. The CairClip O3/NO2 sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists. PMID:27754370
Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements
NASA Technical Reports Server (NTRS)
Garrett, Henry B.; Buelher, Martin G.; Brinza, D.; Patel, J. U.
2005-01-01
An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.
Low Cost Environmental Sensors for Spaceflight: NMP Space Environmental Monitor (SEM) Requirements
NASA Technical Reports Server (NTRS)
Garrett, Henry B.; Buehler, Martin G.; Brinza, D.; Patel, J. U.
2005-01-01
An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.
Deng, Ming; Huang, Can; Liu, Danhui; Jin, Wei; Zhu, Tao
2015-08-10
An ultra-compact optical fiber magnetic field sensor based on a microstructured optical fiber (MOF) modal interference and ferrofluid (FF) has been proposed and experimentally demonstrated. The magnetic field sensor was fabricated by splicing a tapered germanium-doped index guided MOF with six big holes injected with FF to two conventional single-mode fibers. The transmission spectra of the proposed sensor under different magnetic field intensities have been measured and theoretically analyzed. Due to an efficient interaction between the magnetic nanoparticles in FF and the excited cladding mode, the magnetic field sensitivity reaches up to117.9pm/mT with a linear range from 0mT to 30mT. Moreover, the fabrication process of the proposed sensor is simple, easy and cost-effective. Therefore, it will be a promising candidate for military, aviation industry, and biomedical applications, especially, for the applications where the space is limited.
Development of CMOS Active Pixel Image Sensors for Low Cost Commercial Applications
NASA Technical Reports Server (NTRS)
Fossum, E.; Gee, R.; Kemeny, S.; Kim, Q.; Mendis, S.; Nakamura, J.; Nixon, R.; Ortiz, M.; Pain, B.; Zhou, Z.;
1994-01-01
This paper describes ongoing research and development of CMOS active pixel image sensors for low cost commercial applications. A number of sensor designs have been fabricated and tested in both p-well and n-well technologies. Major elements in the development of the sensor include on-chip analog signal processing circuits for the reduction of fixed pattern noise, on-chip timing and control circuits and on-chip analog-to-digital conversion (ADC). Recent results and continuing efforts in these areas will be presented.
Shir, Daniel; Ballard, Zachary S.; Ozcan, Aydogan
2016-01-01
Mechanical flexibility and the advent of scalable, low-cost, and high-throughput fabrication techniques have enabled numerous potential applications for plasmonic sensors. Sensitive and sophisticated biochemical measurements can now be performed through the use of flexible plasmonic sensors integrated into existing medical and industrial devices or sample collection units. More robust sensing schemes and practical techniques must be further investigated to fully realize the potentials of flexible plasmonics as a framework for designing low-cost, embedded and integrated sensors for medical, environmental, and industrial applications. PMID:27547023
Development of a Bioaerosol single particle detector (BIO IN) for the Fast Ice Nucleus CHamber FINCH
NASA Astrophysics Data System (ADS)
Bundke, U.; Reimann, B.; Nillius, B.; Jaenicke, R.; Bingemer, H.
2010-02-01
In this work we present the setup and first tests of our new BIO IN detector. This detector was constructed to classify atmospheric ice nuclei (IN) for their biological content. It is designed to be coupled to the Fast Ice Nucleus CHamber FINCH. If one particle acts as an ice nucleus, it will be at least partly covered with ice at the end of the development section of the FINCH chamber. The device combines an auto-fluorescence detector and a circular depolarization detector for simultaneous detection of biological material and discrimination between water droplets, ice crystals and non activated large aerosol particles. The excitation of biological material with UV light and analysis of auto-fluorescence is a common principle used for flow cytometry, fluorescence microscopy, spectroscopy and imaging. The detection of auto-fluorescence of airborne single particles demands some more experimental effort. However, expensive commercial sensors are available for special purposes, e.g. size distribution measurements. But these sensors will not fit the specifications needed for the FINCH IN counter (e.g. high sample flow of up 10 LPM). The newly developed -low cost- BIO IN sensor uses a single high-power UV LED for the electronic excitation instead of much more expensive UV lasers. Other key advantages of the new sensor are the low weight, compact size, and the little effect on the aerosol sample, which allows it to be coupled with other instruments for further analysis. The instrument will be flown on one of the first missions of the new German research aircraft "HALO" (High Altitude and LOng range).
Low Cost Sensors-Current Capabilities and Gaps
1. Present the findings from the a recent technology review of gas and particulate phase sensors 2. Focus on the lower-cost sensors 3. Discuss current capabilities, estimated range of measurement, selectivity, deployment platforms, response time, and expected range of acceptabl...
Wireless spread-spectrum telesensor chip with synchronous digital architecture
Smith, Stephen F.; Turner, Gary W.; Wintenberg, Alan L.; Emery, Michael Steven
2005-03-08
A fully integrated wireless spread-spectrum sensor incorporating all elements of an "intelligent" sensor on a single circuit chip is capable of telemetering data to a receiver. Synchronous control of all elements of the chip provides low-cost, low-noise, and highly robust data transmission, in turn enabling the use of low-cost monolithic receivers.
Low cost fiber optic sensing of sugar solution
NASA Astrophysics Data System (ADS)
Muthuraju, M. E.; Patlolla, Anurag Reddy; Vadakkapattu Canthadai, Badrinath; Pachava, Vengalrao
2015-03-01
The demand for highly sensitive and reliable sensors to assess the refractive index of liquid get many applications in chemical and biomedical areas. Indeed, the physical parameters such as concentration, pressure and density, etc., can be found using the refractive index of liquid. In contrast to the conventional refractometer for measurement, optical fiber sensor has several advantages like remote sensing, small in size, low cost, immune to EMI etc., In this paper we have discussed determination of refractive index of sugar solution using optical fiber. An intensity modulated low cost plastic fiber optic refractive index sensor has been designed for the study. The sensor is based on principle of change in angle of reflected light caused by refractive index change of the medium surrounding the fiber. The experimental results obtained for the sugar solution of different refractive indices prove that the fiber optic sensor is cable of measuring the refractive indices as well as the concentrations.
WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics
NASA Technical Reports Server (NTRS)
Stekalov, Dmitry; Maleki, Lute; Matsko, Andrey; Savchenkov, Anatoliy; Iltchenko, Vladimir
2007-01-01
Theoretical and experimental investigations have demonstrated the feasibility of compact white-light sensor optics consisting of unitary combinations of (1) low-profile whispering-gallery-mode (WGM) resonators and (2) tapered rod optical waveguides. These sensors are highly wavelength-dispersive and are expected to be especially useful in biochemical applications for measuring absorption spectra of liquids. These sensor optics exploit the properties of a special class of non-diffracting light beams that are denoted Bessel beams because their amplitudes are proportional to Bessel functions of the radii from their central axes. High-order Bessel beams can have large values of angular momentum. In a sensor optic of this type, a low-profile WGM resonator that supports modes having large angular momenta is used to generate high-order Bessel beams. As used here, "low-profile" signifies that the WGM resonator is an integral part of the rod optical waveguide but has a radius slightly different from that of the adjacent part(s).
In Situ Multi-Species (O2, N2, Fuel, Other) Fiber Optic Sensor for Fuel Tank Ullage
NASA Technical Reports Server (NTRS)
Nguyen, Quang-Viet
2007-01-01
A rugged and compact fiber optic sensor system for in situ real-time measurement of nitrogen (N2), oxygen (O2), hydrocarbon (HC) fuel vapors, and other gases has been developed over the past several years at Glenn Research Center. The intrinsically-safe, solid-state fiber optic sensor system provides a 1% precision measurement (by volume) of multiple gases in a 5-sec time window. The sensor has no consumable parts to wear out and requires less than 25 W of electrical power to operate. The sensor head is rugged and compact and is ideal for use in harsh environments such as inside an aircraft fuel tank, or as a feedback sensor in the vent-box of an on-board inert gas generation system (OBIGGS). Multiple sensor heads can be monitored with a single optical detection unit for a cost-effective multi-point sensor system. The present sensor technology is unique in its ability to measure N2 concentration directly, and in its ability to differentiate different types of HC fuels. The present sensor system provides value-added aircraft safety information by simultaneously and directly measuring the nitrogen-oxygen-fuel triplet, which provides the following advantages: (1) information regarding the extent of inerting by N2, (2) information regarding the chemical equivalence ratio, (3) information regarding the composition of the aircraft fuel, and (4) by providing a self-consistent calibration by utilizing a singular sensor for all species. Using the extra information made available by this sensor permits the ignitability of a fuel-oxidizer mixture to be more accurately characterized, which may permit a reduction in the amount of inerting required on a real-time basis, and yet still maintain a fire-safe fuel tank. This translates to an increase in fuel tank fire-safety through a better understanding of the physics of fuel ignition, and at the same time, a reduction in compressed bleed air usage and concomitant aircraft operational costs over the long-run. The present fiber optic sensor can also be used as a false-alarm-free engine/hidden/cargo space fire detector (by measuring increased CO2 and CO, and decreased O2), a multi-point in situ measurement and certification system for halogenated-compound fire protection systems, and for the testing and certification of other aircraft safety sensor systems. The technology (LEW-17826-1) developed in the present sensor system is patent pending.
Investigation of Low Cost Sensor-Based Leak Detection System for Fence Line Applications
With recent technological advances, low-cost time-resolved sensors may become effective tools to support time-integrated passive sampling strategies by helping to decipher origin of emissions in real-time. As part of the Petroleum Refinery Risk and Technology Review, New Source ...
Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators
NASA Technical Reports Server (NTRS)
Simons, Rainee N (Inventor); Miranda, Felix Antonio (Inventor)
2007-01-01
A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.
Comparative study of disinfectants for use in low-cost gravity driven household water purifiers.
Patil, Rajshree A; Kausley, Shankar B; Balkunde, Pradeep L; Malhotra, Chetan P
2013-09-01
Point-of-use (POU) gravity-driven household water purifiers have been proven to be a simple, low-cost and effective intervention for reducing the impact of waterborne diseases in developing countries. The goal of this study was to compare commonly used water disinfectants for their feasibility of adoption in low-cost POU water purifiers. The potency of each candidate disinfectant was evaluated by conducting a batch disinfection study for estimating the concentration of disinfectant needed to inactivate a given concentration of the bacterial strain Escherichia coli ATCC 11229. Based on the concentration of disinfectant required, the size, weight and cost of a model purifier employing that disinfectant were estimated. Model purifiers based on different disinfectants were compared and disinfectants which resulted in the most safe, compact and inexpensive purifiers were identified. Purifiers based on bromine, tincture iodine, calcium hypochlorite and sodium dichloroisocyanurate were found to be most efficient, cost effective and compact with replacement parts costing US$3.60-6.00 for every 3,000 L of water purified and are thus expected to present the most attractive value proposition to end users.
Force Sensing Resistor (FSR): a brief overview and the low-cost sensor for active compliance control
NASA Astrophysics Data System (ADS)
Sadun, A. S.; Jalani, J.; Sukor, J. A.
2016-07-01
Force Sensing Resistors (FSR) sensors are devices that allow measuring static and dynamic forces applied to a contact surface. Their range of responses is basically depending on the variation of its electric resistance. In general, Flexiforce and Interlink are two common types of FSR sensors that are available, cheap and easily found in the market. Studies have shown that the FSR sensors are usually applied for robotic grippers and for biomechanical fields. This paper provides a brief overview of the application of the FSR sensors. Subsequently, two different set of experiments are carried out to test the effectiveness of the Flexiforce and Interlink sensors. First, the hardness detector system (Case Study A) and second, the force-position control system (Case Study B). The hardware used for the experiment was developed from low-cost materials. The results revealed that both FSR sensors are sufficient and reliable to provide a good sensing modality particularly for measuring force. Apart from the low-cost sensors, essentially, the FSR sensors are very useful devices that able to provide a good active compliance control, particularly for the grasping robotic hand.
Yan, Dan; Yang, Yong; Hong, Yingping; Liang, Ting; Yao, Zong; Chen, Xiaoyong; Xiong, Jijun
2018-01-01
Low-cost wireless temperature measurement has significant value in the food industry, logistics, agriculture, portable medical equipment, intelligent wireless health monitoring, and many areas in everyday life. A wireless passive temperature sensor based on PCB (Printed Circuit Board) materials is reported in this paper. The advantages of the sensor include simple mechanical structure, convenient processing, low-cost, and easiness in integration. The temperature-sensitive structure of the sensor is a dielectric-loaded resonant cavity, consisting of the PCB substrate. The sensitive structure also integrates a patch antenna for the transmission of temperature signals. The temperature sensing mechanism of the sensor is the dielectric constant of the PCB substrate changes with temperature, which causes the resonant frequency variation of the resonator. Then the temperature can be measured by detecting the changes in the sensor’s working frequency. The PCB-based wireless passive temperature sensor prototype is prepared through theoretical design, parameter analysis, software simulation, and experimental testing. The high- and low-temperature sensing performance of the sensor is tested, respectively. The resonant frequency decreases from 2.434 GHz to 2.379 GHz as the temperature increases from −40 °C to 125 °C. The fitting curve proves that the experimental data have good linearity. Three repetitive tests proved that the sensor possess well repeatability. The average sensitivity is 347.45 KHz/°C℃ from repetitive measurements conducted three times. This study demonstrates the feasibility of the PCB-based wireless passive sensor, which provides a low-cost temperature sensing solution for everyday life, modern agriculture, thriving intelligent health devices, and so on, and also enriches PCB product lines and applications. PMID:29439393
Non-perturbing voltage measurement in a coaxial cable with slab-coupled optical sensors.
Stan, Nikola; Seng, Frederick; Shumway, LeGrand; King, Rex; Schultz, Stephen
2017-08-20
Voltage in a coaxial cable is measured by an electric-field optical fiber sensor exploiting the proportionality of voltage and electric field in a fixed structure. The sensor is inserted in a hole drilled through the dielectric of the RG-218 coaxial cable and sealed with epoxy to displace all air and prevent the adverse effects of charge buildup during high-voltage measurements. It is shown that the presence of the sensor in the coaxial cable does not significantly increase electrical reflections in the cable. A slab-coupled optical fiber sensor (SCOS) is used for its compact size and dielectric make. The dynamic range of 50 dB is shown experimentally with detection of signals as low as 1 V and up to 157 kV. A low corner of 0.3 Hz is demonstrated and the SCOS is shown to be able to measure 90 ns rise time.
Investigation of a Low Cost Sensor-Based Leak Detection System for Fence Line Applications
With recent technological advances, low-cost time-resolved sensors may become effective tools to support time-integrated passive sampling strategies by helping to decipher origin of emissions in real-time. As part of the Petroleum Refinery Risk and Technology Review, New Source P...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlos H. Rentel
2007-03-31
The objective of this project was to create a low-cost, robust anticipatory wireless sensor network (A-WSN) to ensure the security and reliability of the United States energy infrastructure. This document highlights Eaton Corporation's plan to bring these technologies to market.
Spatial and Temporal Trends of Air Pollutants in the South Coast Basin Using Low Cost Sensors
The emergence of small, portable, low-cost air sensors has encouraged a shift from traditional monitoring approaches for air quality. The U.S. Environmental Protection Agency (U.S. EPA), in collaboration with the South Coast Air Quality Management District’s (SCAQMD) Air Quality ...
LOW COST ORGANIC GAS SENSORS ON PLASTIC FOR DISTRIBUTED ENVIRONMENTAL MONITORING
This project focused on the development of low-cost arrayed organic sensors for environmental monitoring applications. All of the major goals of the original project have been achieved in the 3-year period of this grant.
In Year 1 of the project, we successfully deve...
Wilkes, Thomas C; McGonigle, Andrew J S; Pering, Tom D; Taggart, Angus J; White, Benjamin S; Bryant, Robert G; Willmott, Jon R
2016-10-06
Here, we report, for what we believe to be the first time, on the modification of a low cost sensor, designed for the smartphone camera market, to develop an ultraviolet (UV) camera system. This was achieved via adaptation of Raspberry Pi cameras, which are based on back-illuminated complementary metal-oxide semiconductor (CMOS) sensors, and we demonstrated the utility of these devices for applications at wavelengths as low as 310 nm, by remotely sensing power station smokestack emissions in this spectral region. Given the very low cost of these units, ≈ USD 25, they are suitable for widespread proliferation in a variety of UV imaging applications, e.g., in atmospheric science, volcanology, forensics and surface smoothness measurements.
Wong, Kevin S K; Jian, Yifan; Cua, Michelle; Bonora, Stefano; Zawadzki, Robert J; Sarunic, Marinko V
2015-02-01
Wavefront sensorless adaptive optics optical coherence tomography (WSAO-OCT) is a novel imaging technique for in vivo high-resolution depth-resolved imaging that mitigates some of the challenges encountered with the use of sensor-based adaptive optics designs. This technique replaces the Hartmann Shack wavefront sensor used to measure aberrations with a depth-resolved image-driven optimization algorithm, with the metric based on the OCT volumes acquired in real-time. The custom-built ultrahigh-speed GPU processing platform and fast modal optimization algorithm presented in this paper was essential in enabling real-time, in vivo imaging of human retinas with wavefront sensorless AO correction. WSAO-OCT is especially advantageous for developing a clinical high-resolution retinal imaging system as it enables the use of a compact, low-cost and robust lens-based adaptive optics design. In this report, we describe our WSAO-OCT system for imaging the human photoreceptor mosaic in vivo. We validated our system performance by imaging the retina at several eccentricities, and demonstrated the improvement in photoreceptor visibility with WSAO compensation.
Phase II, Compact AMS System for Biological Tracer Detection Final Report CRADA No. TSV-1533-96
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, T. A.; Hamm, R. W.
2017-11-01
The objective of this collaboration between LLNL and AccSys Technology, Inc. of Pleasanton, California was to build and demonstrate a low cost, compact tritium (3H) Accelerator Mass Spectrometer (AMS) system matched to the requirements of biomedical research.
Fan, Bingfei; Li, Qingguo; Wang, Chao; Liu, Tao
2017-01-01
Magnetic and inertial sensors have been widely used to estimate the orientation of human segments due to their low cost, compact size and light weight. However, the accuracy of the estimated orientation is easily affected by external factors, especially when the sensor is used in an environment with magnetic disturbances. In this paper, we propose an adaptive method to improve the accuracy of orientation estimations in the presence of magnetic disturbances. The method is based on existing gradient descent algorithms, and it is performed prior to sensor fusion algorithms. The proposed method includes stationary state detection and magnetic disturbance severity determination. The stationary state detection makes this method immune to magnetic disturbances in stationary state, while the magnetic disturbance severity determination helps to determine the credibility of magnetometer data under dynamic conditions, so as to mitigate the negative effect of the magnetic disturbances. The proposed method was validated through experiments performed on a customized three-axis instrumented gimbal with known orientations. The error of the proposed method and the original gradient descent algorithms were calculated and compared. Experimental results demonstrate that in stationary state, the proposed method is completely immune to magnetic disturbances, and in dynamic conditions, the error caused by magnetic disturbance is reduced by 51.2% compared with original MIMU gradient descent algorithm. PMID:28534858
Open Loop Structure Low Cost Integrated Differential Inductive Micro Magnetic Volumetric Bio-Sensors
NASA Astrophysics Data System (ADS)
Khodadadi, Mohammad; Chang, Long; Litvinov, Dimitri
This investigation proposes a study, model, simulate and experiment innovative very low cost Magnetic induction biosensor for point of care diagnostics. The biosensor consists of 2 ``semi-loops'' in a micro fluidic channel, one as a sensor and one as a reference, the design takes advantage of microfabrication processes to produce more precise structures to improve sensitivity. Besides the attractively low cost, this biosensor has many advantages. Since the detector is basically a shaped wire, it is inherently robust and reliable. Typical errors in fabricating the wires will not affect its performance and it is sensing volumetric, unlike GMR-based sensors used in biosensor systems that boast single particle detection. Due to small dimensions the sensors do not need to be calibrated. This sensor also has a large range of detection since its sensitivity is proportional to the excitation frequency. Being able to sense Magnetic nano particles in the volume is an advantage in term of trapping MNPs and sensitivity and functionality. Basically, this new brilliant design, fill the gap between the fabricated sensors and hand wounded sensors.
Novel Low-Cost Sensor for Human Bite Force Measurement
Fastier-Wooller, Jarred; Phan, Hoang-Phuong; Dinh, Toan; Nguyen, Tuan-Khoa; Cameron, Andrew; Öchsner, Andreas; Dao, Dzung Viet
2016-01-01
This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement. PMID:27509496
High-grade, compact spectrometers for Earth observation from SmallSats
NASA Astrophysics Data System (ADS)
van der Wal, L. F.; de Goeij, B. T. G.; Jansen, R.; Oosterling, J. A. J.; Snijders, B.
2016-10-01
The market for nano- and microsatellites is developing rapidly. There is a strong focus on 2D imaging of the Earth's surface, with limited possibilities to obtain spectral information. More demanding applications, such as monitoring trace gases, aerosols or water quality still require advanced imaging instruments, which are large, heavy and expensive. In recent years TNO has investigated and developed different innovative designs to realize advanced spectrometers for space applications in a more compact and cost-effective manner. This offers multiple advantages: a compact instrument can be flown on a much smaller platform (nano- or microsatellite); a low-cost instrument opens up the possibility to fly multiple instruments in a satellite constellation, improving both global coverage and temporal sampling (e.g. to study diurnal processes); a constellation of low-cost instruments may provide added value to the larger scientific and operational satellite missions (e.g. the Copernicus Sentinel missions); and a small, lightweight spectrometer can also be mounted easily on a high-altitude UAV (offering high spatial resolution). Last but not least, a low-cost instrument may allow to break through the `cost spiral': lower cost will allow to take more risk and thus progress more quickly. This may lead to a much faster development cycle than customary for current Earth Observation instruments. To explore the potential of a constellation of low-cost instruments a consortium of Dutch partners was formed, which currently consists of Airbus Defence and Space Netherlands, ISISpace, S and T and TNO. In this paper we will illustrate this new design approach by using the most advanced design of a hyperspectral imaging spectrometer (named `Spectrolite') as an example. We will discuss the different design and manufacturing techniques that were used to realize this compact and low-cost design. Laboratory tests as well as the first preliminary results of airborne measurements with the Spectrolite breadboard will be presented and discussed. The design of Spectrolite offers the flexibility to tune its performance (spectral range, spectral resolution) to a specific application. Thus, based on the same basic system design, Spectrolite offers a range of applications to different clients. To illustrate this, we will present a mission concept to monitor NO2 concentrations over urban areas at high spatial resolution, based on a constellation of small satellites.
Community Air Sensor Network (CAIRSENSE) Project: Lower Cost, Continuous Ambient Monitoring Methods
Advances in air pollution sensor technology have enabled the development of small and low cost systems to measure outdoor air pollution. The deployment of numerous sensors across a small geographic area would have potential benefits to supplement existing monitoring networks and ...
Technology for low-cost PIR security sensors
NASA Astrophysics Data System (ADS)
Liddiard, Kevin C.
2008-03-01
Current passive infrared (PIR) security sensors employing pyroelectric detectors are simple, cheap and reliable, but have several deficiencies. These sensors, developed two decades ago, are essentially short-range moving-target hotspot detectors. They cannot detect slow temperature changes, and thus are unable to respond to radiation stimuli indicating potential danger such as overheating electrical appliances and developing fires. They have a poor optical resolution and limited ability to recognize detected targets. Modern uncooled thermal infrared technology has vastly superior performance but as yet is too costly to challenge the PIR security sensor market. In this paper microbolometer technology will be discussed which can provide enhanced performance at acceptable cost. In addition to security sensing the technology has numerous applications in the military, industrial and domestic markets where target range is short and low cost is paramount.
Ambient and laboratory evaluation of a low-cost particulate matter sensor.
Kelly, K E; Whitaker, J; Petty, A; Widmer, C; Dybwad, A; Sleeth, D; Martin, R; Butterfield, A
2017-02-01
Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200-850 μg/m 3 ). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM 2.5 concentrations exceed 40 μg/m 3 . These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an appropriate correction factor for the target environmental conditions if the user wants to compare the results to FEM/FRMs. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hyperspectral Microwave Atmospheric Sounder (HyMAS) - New Capability in the CoSMIR-CoSSIR Scanhead
NASA Technical Reports Server (NTRS)
Hilliard, Lawrence; Racette, Paul; Blackwell, William; Galbraith, Christopher; Thompson, Erik
2015-01-01
Lincoln Laboratory and NASA's Goddard Space Flight Center have teamed to re-use an existing instrument platform, the CoSMIR/CoSSIR system for atmospheric sounding, to develop a new capability in hyperspectral filtering, data collection, and display. The volume of the scanhead accomodated an intermediate frequency processor(IFP), that provides the filtering and digitization of the raw data and the interoperable remote component (IRC) adapted to CoSMIR, CoSSIR, and HyMAS that stores and archives the data with time tagged calibration and navigation data. The first element of the work is the demonstration of a hyperspectral microwave receiver subsystem that was recently shown using a comprehensive simulation study to yield performance that substantially exceeds current state-of-the-art. Hyperspectral microwave sounders with approximately 100 channels offer temperature and humidity sounding improvements similar to those obtained when infrared sensors became hyperspectral, but with the relative insensitivity to clouds that characterizes microwave sensors. Hyperspectral microwave operation is achieved using independent RF antenna/receiver arrays that sample the same area/volume of the Earth's surface/atmosphere at slightly different frequencies and therefore synthesize a set of dense, finely spaced vertical weighting functions. The second, enabling element of the proposal is the development of a compact 52-channel Intermediate Frequency processor module. A principal challenge in the development of a hyperspectral microwave system is the size of the IF filter bank required for channelization. Large bandwidths are simultaneously processed, thus complicating the use of digital back-ends with associated high complexities, costs, and power requirements. Our approach involves passive filters implemented using low-temperature co-fired ceramic (LTCC) technology to achieve an ultra-compact module that can be easily integrated with existing radio frequency front-end technology. This IF processor is universally applicable to other microwave sensing missions requiring compact IF spectrometry. The data include 52 operational channels with low IF module volume (less than 100 cubic centimeters) and mass (less than 300 grams) and linearity better than 0.3 percent over a 330,000 dynamic range.
An ultrasensitive and low-cost graphene sensor based on layer-by-layer nano self-assembly
NASA Astrophysics Data System (ADS)
Zhang, Bo; Cui, Tianhong
2011-02-01
The flexible cancer sensor based on layer-by-layer self-assembled graphene reported in this letter demonstrates features including ultrahigh sensitivity and low cost due to graphene material properties in nature, self-assembly technique, and polyethylene terephthalate substrate. According to the conductance change of self-assembled graphene, the label free and labeled graphene sensors are capable of detecting very low concentrations of prostate specific antigen down to 4 fg/ml (0.11 fM) and 0.4 pg/ml (11 fM), respectively, which are three orders of magnitude lower than carbon nanotube sensors under the same conditions of design, manufacture, and measurement.
Compact water depth sensor with LPFG using the photoelastic effect and heat-shrinkable tube
NASA Astrophysics Data System (ADS)
Takama, Shinya; Kudomi, Takamasa; Ohashi, Masaharu; Miyoshi, Yuji
2011-12-01
We propose a compact water depth sensor with a long period fiber grating (LPFG) using a heat-shrinkable tube. The pressure property of the LPFG is investigated experimentally to confirm the feasibility of the water depth sensor. Moreover, the water depth in the 2m long water-filled pipe is successfully estimated by the proposed water sensors.
A Leo Satellite Navigation Algorithm Based on GPS and Magnetometer Data
NASA Technical Reports Server (NTRS)
Deutschmann, Julie; Harman, Rick; Bar-Itzhack, Itzhack
2001-01-01
The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately, a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes. This work presents the development of a technique to eliminate numerical differentiation of the GPS phase measurements and also compares the use of one versus two GPS satellites.
Compact Full-Field Ion Detector System for SmallSats Beyond LEO
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.; Clark, Pamela E.; McNeil, Roger R.
2014-01-01
NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop a Compact Full-Field Ion Detector System (CFIDS). The CFIDS is designed to be an extremely compact, low cost instrument, capable of being flown on a wide variety of deep space platforms, to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments.
NASA Astrophysics Data System (ADS)
Kim, Jinsol; Shusterman, Alexis A.; Lieschke, Kaitlyn J.; Newman, Catherine; Cohen, Ronald C.
2018-04-01
The newest generation of air quality sensors is small, low cost, and easy to deploy. These sensors are an attractive option for developing dense observation networks in support of regulatory activities and scientific research. They are also of interest for use by individuals to characterize their home environment and for citizen science. However, these sensors are difficult to interpret. Although some have an approximately linear response to the target analyte, that response may vary with time, temperature, and/or humidity, and the cross-sensitivity to non-target analytes can be large enough to be confounding. Standard approaches to calibration that are sufficient to account for these variations require a quantity of equipment and labor that negates the attractiveness of the sensors' low cost. Here we describe a novel calibration strategy for a set of sensors, including CO, NO, NO2, and O3, that makes use of (1) multiple co-located sensors, (2) a priori knowledge about the chemistry of NO, NO2, and O3, (3) an estimate of mean emission factors for CO, and (4) the global background of CO. The strategy requires one or more well calibrated anchor points within the network domain, but it does not require direct calibration of any of the individual low-cost sensors. The procedure nonetheless accounts for temperature and drift, in both the sensitivity and zero offset. We demonstrate this calibration on a subset of the sensors comprising BEACO2N, a distributed network of approximately 50 sensor nodes
, each measuring CO2, CO, NO, NO2, O3 and particulate matter at 10 s time resolution and approximately 2 km spacing within the San Francisco Bay Area.
Harnessing the potential of the Kinect sensor for psychiatric rehabilitation for stroke survivors.
Zhang, Melvyn W B; Ho, Roger C M
2016-03-04
Dominques et al. in their recent article described how low-cost sensors, such as Microsoft Kinect could be utilized for the measurement of various anthropometric measures. With the recent advances in sensors and sensor based technology, along with the rapid advancement in E-health, Microsoft Kinect has been increasingly recognized by researchers and bioengineers to be a low-cost sensor that could help in the collation of various measurements and various data. A recent systematic review done by Da Gama et al. (2015) have looked into the potential of Kinect in terms of motor rehabilitation. The systematic review highlighted the tremendous potential of the sensors and has clearly stated that there is a need for further studies evaluating its potential for rehabilitation. Zhang et al. (2015) in their recent article have advocated several reasons as to why biosensors are pertinent for stroke rehabilitation. Of note, recent studies done by the World Health Organization have highlighted that stroke is a growing epidemic. Aside to the utilization of smartphone based sensors for stroke rehabilitation, as proposed by Zhang et al. (2015), researchers have also investigated the use of other low cost alternatives, such as Kinect, to facilitate the rehabilitation of stroke survivors. Whilst it may seemed like that has been quite extensive evaluation of the Kinect sensor for stroke rehabilitation, one core area that bio-engineers and researchers have not looked into is that of the psychiatric and mental health issues that might at times arise following a stroke. It is thus the aim of this letter to address how such a sensor could be tapped upon for psychiatric rehabilitation amongst stroke survivors. To this end, the authors have thus conceptualized a game that could help in the cognitive remediation for stroke survivors using low cost Kinect sensors.
Chemicapacitive microsensors for detection of explosives and TICs
NASA Astrophysics Data System (ADS)
Patel, Sanjay V.; Hobson, Stephen T.; Cemalovic, Sabina; Mlsna, Todd E.
2005-10-01
Seacoast Science develops chemical sensors that use polymer-coated micromachined capacitors to measure the dielectric permittivity of an array of selectively absorbing materials. We present recent results demonstrating the sensor technology's capability to detect components in explosives and toxic industrial chemicals. These target chemicals are detected with functionalized polymers or network materials, chosen for their ability to adsorb chemicals. When exposed to vapors or gases, the permittivity of these sorbent materials changes depending on the strength of the vapor-sorbent interaction. Sensor arrays made of ten microcapacitors on a single chip have been previously shown to detect vapors of organic compounds (chemical warfare agents, industrial solvents, fuels) and inorganic gases (SO2, CO2, NO2). Two silicon microcapacitor structures were used, one with parallel electrode plates and the other with interdigitated "finger-like" electrodes. The parallel-plates were approximately 300 μm wide and separated by 750 nm. The interdigitated electrodes were approximately 400 μm long and were elevated above the substrate to provide faster vapor access. Eight to sixteen of these capacitors are fabricated on chips that are 5 x 2 mm and are packaged in less than 50 cm3 with supporting electronics and batteries, all weighing less than 500 grams. The capacitors can be individually coated with different materials creating a small electronic nose that produces different selectivity patterns in response to different chemicals. The resulting system's compact size, low-power consumption and low manufacturing costs make the technology ideal for integration into various systems for numerous applications.
Manufacturing Demonstration Facility: Roll-to-Roll Processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Datskos, Panos G; Joshi, Pooran C; List III, Frederick Alyious
This Manufacturing Demonstration Facility (MDF)e roll-to-roll processing effort described in this report provided an excellent opportunity to investigate a number of advanced manufacturing approaches to achieve a path for low cost devices and sensors. Critical to this effort is the ability to deposit thin films at low temperatures using nanomaterials derived from nanofermentation. The overarching goal of this project was to develop roll-to-roll manufacturing processes of thin film deposition on low-cost flexible substrates for electronics and sensor applications. This project utilized ORNL s unique Pulse Thermal Processing (PTP) technologies coupled with non-vacuum low temperature deposition techniques, ORNL s clean roommore » facility, slot dye coating, drop casting, spin coating, screen printing and several other equipment including a Dimatix ink jet printer and a large-scale Kyocera ink jet printer. The roll-to-roll processing project had three main tasks: 1) develop and demonstrate zinc-Zn based opto-electronic sensors using low cost nanoparticulate structures manufactured in a related MDF Project using nanofermentation techniques, 2) evaluate the use of silver based conductive inks developed by project partner NovaCentrix for electronic device fabrication, and 3) demonstrate a suite of low cost printed sensors developed using non-vacuum deposition techniques which involved the integration of metal and semiconductor layers to establish a diverse sensor platform technology.« less
Investigation of a low-cost magneto-inductive magnetometer for space science applications
NASA Astrophysics Data System (ADS)
Regoli, Leonardo H.; Moldwin, Mark B.; Pellioni, Matthew; Bronner, Bret; Hite, Kelsey; Sheinker, Arie; Ponder, Brandon M.
2018-03-01
A new sensor for measuring low-amplitude magnetic fields that is ideal for small spacecraft is presented. The novel measurement principle enables the fabrication of a low-cost sensor with low power consumption and with measuring capabilities that are comparable to recent developments for CubeSat applications. The current magnetometer, a software-modified version of a commercial sensor, is capable of detecting fields with amplitudes as low as 8.7 nT at 40 Hz and 2.7 nT at 1 Hz, with a noise floor of 4 pT/
Martinaitis, Arnas; Daunoraviciene, Kristina
2018-05-18
Long sitting causes many health problems for people. Healthy sitting monitoring systems, like real-time pressure distribution measuring, is in high demand and many methods of posture recognition were developed. Such systems are usually expensive and hardly available for the regular user. The aim of study is to develop low cost but sensitive enough pressure sensors and posture monitoring system. New self-made pressure sensors have been developed and tested, and prototype of pressure distribution measuring system was designed. Sensors measured at average noise amplitude of a = 56 mV (1.12%), average variation in sequential measurements of the same sensor s = 17 mV (0.34%). Signal variability between sensors averaged at 100 mV (2.0%). Weight to signal dependency graph was measured and hysteresis calculated. Results suggested the use of total sixteen sensors for posture monitoring system with accuracy of < 1.5% after relaxation and repeatability of around 2%. Results demonstrate that hand-made sensor sensitivity and repeatability are acceptable for posture monitoring, and it is possible to build low cost pressure distribution measurement system with graphical visualization without expensive equipment or complicated software.
Strategy Guideline: Compact Air Distribution Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burdick, A.
2013-06-01
This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward themore » exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.« less
ULTRA-LOW POWER CO2 SENSOR FOR INTELLIGENT BUILDING CONTROL - PHASE I
The proposed EPA SBIR Phase I program will create a novel ultra-low power and low-cost microfabricated CO2 sensor. The initial developments of sensor technology will serve the very large Demand Controlled Ventilation market that has been identified by KWJ and its...
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform.
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-15
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional "chilled-mirror" hygrometers. Moreover, this DPS outperforms conventional "chilled-mirror" hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
NASA Astrophysics Data System (ADS)
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
Compact SPAD-Based Pixel Architectures for Time-Resolved Image Sensors
Perenzoni, Matteo; Pancheri, Lucio; Stoppa, David
2016-01-01
This paper reviews the state of the art of single-photon avalanche diode (SPAD) image sensors for time-resolved imaging. The focus of the paper is on pixel architectures featuring small pixel size (<25 μm) and high fill factor (>20%) as a key enabling technology for the successful implementation of high spatial resolution SPAD-based image sensors. A summary of the main CMOS SPAD implementations, their characteristics and integration challenges, is provided from the perspective of targeting large pixel arrays, where one of the key drivers is the spatial uniformity. The main analog techniques aimed at time-gated photon counting and photon timestamping suitable for compact and low-power pixels are critically discussed. The main features of these solutions are the adoption of analog counting techniques and time-to-analog conversion, in NMOS-only pixels. Reliable quantum-limited single-photon counting, self-referenced analog-to-digital conversion, time gating down to 0.75 ns and timestamping with 368 ps jitter are achieved. PMID:27223284
High-resolution compact shear stress sensor for direct measurement of skin friction in fluid flow
NASA Astrophysics Data System (ADS)
Xu, Muchen; Kim, Chang-Jin ``Cj''
2015-11-01
The high-resolution measurement of skin friction in complex flows has long been of great interest but also a challenge in fluid mechanics. Compared with indirect measurement methods (e.g., laser Doppler velocimetry), direct measurement methods (e.g., floating element) do not involve any analogy and assumption but tend to suffer from instrumentation challenges, such as low sensing resolution or misalignments. Recently, silicon micromachined floating plates showed good resolution and perfect alignment but were too small for general purposes and too fragile to attach other surface samples repeatedly. In this work, we report a skin friction sensor consisting of a monolithic floating plate and a high-resolution optical encoder to measure its displacement. The key for the high resolution is in the suspension beams, which are very narrow (e.g., 0.25 mm) to sense small frictions along the flow direction but thick (e.g., 5 mm) to be robust along all other directions. This compact, low profile, and complete sensor is easy to use and allows repeated attachment and detachment of surface samples. The sheer-stress sensor has been tested in water tunnel and towing tank at different flow conditions, showing high sensing resolution for skin friction measurement. Supported by National Science Foundation (NSF) (No. 1336966) and Defense Advanced Research Projects Agency (DARPA) (No. HR0011-15-2-0021).
Piezoelectric assisted smart satellite structure (PEASSS): an innovative low cost nano-satellite
NASA Astrophysics Data System (ADS)
Rockberger, D.; Abramovich, H.
2014-03-01
The present manuscript is aimed at describing the PEASSS - PiezoElectric Assisted Smart Satellite Structure project, which was initiated at the beginning of 2013 and financed by the Seventh Framework Program (FP7) of the European Commission. The aims of the project were to develop, manufacture, test and qualify "smart structures" which combine composite panels, piezoelectric materials, and next generation sensors, for autonomously improved pointing accuracy and power generation in space. The smart panels will enable fine angle control, and thermal and vibration compensation, improving all types of future Earth observations, such as environmental and planetary mapping, border and regional imaging. This new technology will help keep Europe on the cutting edge of space research, potentially improving the cost and development time for more accurate future sensor platforms including synthetic aperture optics, moving target detection and identification, and compact radars. The system components include new nano-satellite electronics, a piezo power generation system based on the pyroelectric effect, a piezo actuated smart structure, and a fiber-optic sensor and interrogator system. The present paper will deal only with two of the components, namely the piezo power generation system and the piezo actuated smart structure The designs are going to be prototyped into breadboard models for functional development and testing. Following completion of operational breadboards, components will evolve to flight-test ready hardware and related software, ready to be integrated into a working satellite. Once the nanosattelite is assembled, on ground tests will be performed. Finally, the satellite will be launched and tested in space at the end of 2015.
Experimental study of low-cost fiber optic distributed temperature sensor system performance
NASA Astrophysics Data System (ADS)
Dashkov, Michael V.; Zharkov, Alexander D.
2016-03-01
The distributed control of temperature is an actual task for various application such as oil & gas fields, high-voltage power lines, fire alarm systems etc. The most perspective are optical fiber distributed temperature sensors (DTS). They have advantages on accuracy, resolution and range, but have a high cost. Nevertheless, for some application the accuracy of measurement and localization aren't so important as cost. The results of an experimental study of low-cost Raman based DTS based on standard OTDR are represented.
Self-calibration for lensless color microscopy.
Flasseur, Olivier; Fournier, Corinne; Verrier, Nicolas; Denis, Loïc; Jolivet, Frédéric; Cazier, Anthony; Lépine, Thierry
2017-05-01
Lensless color microscopy (also called in-line digital color holography) is a recent quantitative 3D imaging method used in several areas including biomedical imaging and microfluidics. By targeting cost-effective and compact designs, the wavelength of the low-end sources used is known only imprecisely, in particular because of their dependence on temperature and power supply voltage. This imprecision is the source of biases during the reconstruction step. An additional source of error is the crosstalk phenomenon, i.e., the mixture in color sensors of signals originating from different color channels. We propose to use a parametric inverse problem approach to achieve self-calibration of a digital color holographic setup. This process provides an estimation of the central wavelengths and crosstalk. We show that taking the crosstalk phenomenon into account in the reconstruction step improves its accuracy.
Duan, Lingyan; D'hooge, Dagmar R; Spoerk, Martin; Cornillie, Pieter; Cardon, Ludwig
2018-05-29
Highly sensitive conductive polymer composites (CPCs) are designed, employing a facile and low-cost extrusion manufacturing process for both low and high strain sensing in the field of e.g. structural health/damage monitoring and human body movement tracking. Focus is on the morphology control for extrusion processed carbon black (CB)-filled CPCs, utilizing binary and ternary composites based on thermoplastic polyurethane (TPU) and olefin block copolymer (OBC). The relevance of the correct CB amount, kinetic control through a variation of the compounding sequence, and thermodynamic control induced by annealing is highlighted, considering a wide range of experimental (e.g. static and dynamic resistance/SEM/rheological measurements) and theoretical analyses. High CB mass fractions (20 m%) are needed for OBC (or TPU)-CB binary composites but only lead to an intermediate sensitivity as their conductive network is fully-packed and therefore difficult to be truly destructed. Annealing is needed to enable a monotonic increase of the relative resistance with respect to strain. With ternary composites a much higher sensitivity with a clearer monotonic increase results provided that a low CB mass fraction (10-16 m%) is used and annealing is applied. In particular, with CB first dispersed in OBC and annealing a less compact, hence, brittle conductive network (10-12 m% CB) is obtained, allowing high performance sensing.
Towards real-time assimilation of crowdsourced observations in hydrological modeling
NASA Astrophysics Data System (ADS)
Mazzoleni, Maurizio; Verlaan, Martin; Alfonso, Leonardo; Norbiato, Daniele; Monego, Martina; Ferri, Michele; Solomatine, Dimitri
2016-04-01
The continued technological advances have stimulated the spread of low-cost sensors that can be used by citizens to provide crowdsourced observations (CO) of different hydrological variables. An example of such low-cost sensors is a staff gauge connected to a QR code on which people can read the water level indication and send the measurement via a mobile phone application. The goal of this study is to assess the combined effect of the assimilation of CO coming from a distributed network of low-cost sensors, and the existing streamflow observations from physical sensors, on the performance of a semi-distributed hydrological model. The methodology is applied to the Bacchiglione catchment, North East of Italy, where an early warning system is used by the Alto Adriatico Water Authority to issue forecasted water level along the river network which cross important cities such as Vicenza and Padua. In this study, forecasted precipitation values are used as input in the hydrological model to estimate the simulated streamflow hydrograph used as boundary condition for the hydraulic model. Observed precipitation values are used to generate realistic synthetic streamflow values with various characteristics of arrival frequency and accuracy, to simulate CO coming at irregular time steps. These observations are assimilated into the semi-distributed model using a Kalman filter based method. The results of this study show that CO, asynchronous in time and with variable accuracy, can still improve flood prediction when integrated in hydrological models. When both physical and low-cost sensors are located at the same places, the assimilation of CO gives the same model improvement than the assimilation of physical observations only for high number of non-intermittent sensors. However, the integration of observations from low-cost sensors and single physical sensors can improve the flood prediction even when small a number of intermittent CO are available. This study is part of the FP7 European Project WeSenseIt Citizen Water Observatory (www.http://wesenseit.eu/).
Tanner, Timo; Antikainen, Osmo; Ehlers, Henrik; Yliruusi, Jouko
2017-06-30
With modern tableting machines large amounts of tablets are produced with high output. Consequently, methods to examine powder compression in a high-velocity setting are in demand. In the present study, a novel gravitation-based method was developed to examine powder compression. A steel bar is dropped on a punch to compress microcrystalline cellulose and starch samples inside the die. The distance of the bar is being read by a high-accuracy laser displacement sensor which provides a reliable distance-time plot for the bar movement. In-die height and density of the compact can be seen directly from this data, which can be examined further to obtain information on velocity, acceleration and energy distribution during compression. The energy consumed in compact formation could also be seen. Despite the high vertical compression speed, the method was proven to be cost-efficient, accurate and reproducible. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Brown, S. T.; Focardi, P.; Kitiyakara, A.; Maiwald, F.; Milligan, L.; Montes, O.; Padmanabhan, S.; Redick, R.; Russell, D.
2017-12-01
Passive microwave radiometer systems have been providing important Earth observations for over 30 years, including by not limited to surface wind vector, atmospheric and surface temperature, water vapor, clouds, precipitation, snow and sea ice. These data are critical for weather forecasting and the longevity of the record, along with careful calibration, has also enabled the extraction of climate records. But the future of these systems, conically scanning systems in particular, is uncertain. These sensors are have typically been developed at high cost and deployed on large spacecraft. A solution may lie in smaller, lower-cost but equally capable sensors manifested on free-flying small-satellites which can open the door to new possibilities and an avenue for sustainable passive microwave observation. Among the possibilities are deployment in constellations to shorten revisit time to improve weather forecasting or routine deployment of single sensors over time to ensure an unbroken long duration climate record. The Compact Ocean Wind Vector Radiometer (COWVR) mission, formally the US Air Force ORS-6 mission, will demonstrate a new generation conically scanning passive microwave radiometer on a small satellite. COWVR is an 18-34 GHz fully polarimetric radiometer with a 75cm aperture designed to provide measurements of ocean vector winds with an accuracy that meets or exceeds that provided by WindSat in all non-precipitating conditions, but using a simpler design which has both performance and cost advantages. This paper will give an overview of the COWVR instrument and mission and its performance estimated from pre-launch calibration data. While the COWVR mission is a focused technology demonstration mission, the sensor design is scalable to a much broader frequency range while retaining its low-cost advantage. We will describe extensions of the COWVR design that have been developed and the capabilities of such systems when deployed in a constellation scenario or climate monitoring scenario. We will also describe deployable reflector technologies being developed at JPL to enable large apertures (>2-meter) to stow inside an ESPA volume (<80cm) and be suitable for operation from 6-200 GHz. This removes any limitations on the spatial resolution of the sensor, even when launched as a ESPA secondary payload.
Wilkes, Thomas C.; McGonigle, Andrew J. S.; Pering, Tom D.; Taggart, Angus J.; White, Benjamin S.; Bryant, Robert G.; Willmott, Jon R.
2016-01-01
Here, we report, for what we believe to be the first time, on the modification of a low cost sensor, designed for the smartphone camera market, to develop an ultraviolet (UV) camera system. This was achieved via adaptation of Raspberry Pi cameras, which are based on back-illuminated complementary metal-oxide semiconductor (CMOS) sensors, and we demonstrated the utility of these devices for applications at wavelengths as low as 310 nm, by remotely sensing power station smokestack emissions in this spectral region. Given the very low cost of these units, ≈ USD 25, they are suitable for widespread proliferation in a variety of UV imaging applications, e.g., in atmospheric science, volcanology, forensics and surface smoothness measurements. PMID:27782054
NASA Astrophysics Data System (ADS)
Pikelnaya, O.; Polidori, A.; Wimmer, R.; Mellqvist, J.; Samuelsson, J.; Marianne, E.; Andersson, P.; Brohede, S.; Izos, O.
2017-12-01
Industrial facilities such as refineries and oil processing facilities can be sources of chemicals adversely affecting human health, for example aromatic hydrocarbons and formaldehyde. In an urban setting, such as the South Coast Air Basin (SCAB), exposure to harmful air pollutants (HAP's) for residents of communities neighboring such facilities is of serious concern. Traditionally, exposure assessments are performed by modeling a community exposure using emission inventories and data collected at fixed air monitoring sites. However, recent field measurements found that emission inventories may underestimate HAP emissions from refineries; and HAP measurements data from fixed sites is lacking spatial resolution; as a result, the impact of HAP emissions on communities is highly uncertain. The next generation air monitoring technologies can help address these challenges. For example, dense "low-cost" sensors allow continuous monitoring of concentrations of pollutants within communities with high temporal- and spatial- resolution, and optical remote sensing (ORS) technologies offer measurements of emission fluxes and real-time ground-concentration mapping of HAPs. South Coast Air Quality Management District (SCAQMD) is currently conducting a multi-year study using ORS methods and "low-cost" Volatile Organic Compounds (VOCs) sensors to monitor HAP emissions from selected industrial facilities in the SCAB and their ambient concentrations in neighboring communities. For this purpose, quarterly mobile ORS surveys are conducted to quantify facility-wide emissions for VOCs, aromatic hydrocarbons and HCHO, and to collect ground-concentration profiles of these pollutants inside neighboring communities. Additionally, "low-cost" sensor nodes for deployment in neighborhood(s) downwind of the facilities have been developed in order to obtain long-term, granular data on neighborhood VOC concentrations, During this presentation we will discuss initial results of quarterly ORS surveys and pilot "low-cost" sensor deployments. We will also outline benefits of using a combination of mobile ORS surveys and "low-cost" sensor networks for community exposure monitoring.
Compact Tactile Sensors for Robot Fingers
NASA Technical Reports Server (NTRS)
Martin, Toby B.; Lussy, David; Gaudiano, Frank; Hulse, Aaron; Diftler, Myron A.; Rodriguez, Dagoberto; Bielski, Paul; Butzer, Melisa
2004-01-01
Compact transducer arrays that measure spatial distributions of force or pressure have been demonstrated as prototypes of tactile sensors to be mounted on fingers and palms of dexterous robot hands. The pressure- or force-distribution feedback provided by these sensors is essential for the further development and implementation of robot-control capabilities for humanlike grasping and manipulation.
Salim, Shelly; Moh, Sangman; Choi, Dongmin; Chung, Ilyong
2014-08-11
A cognitive radio sensor network (CRSN) is a wireless sensor network whose sensor nodes are equipped with cognitive radio capability. Clustering is one of the most challenging issues in CRSNs, as all sensor nodes, including the cluster head, have to use the same frequency band in order to form a cluster. However, due to the nature of heterogeneous channels in cognitive radio, it is difficult for sensor nodes to find a cluster head. This paper proposes a novel energy-efficient and compact clustering scheme named clustering with temporary support nodes (CENTRE). CENTRE efficiently achieves a compact cluster formation by adopting two-phase cluster formation with fixed duration. By introducing a novel concept of temporary support nodes to improve the cluster formation, the proposed scheme enables sensor nodes in a network to find a cluster head efficiently. The performance study shows that not only is the clustering process efficient and compact but it also results in remarkable energy savings that prolong the overall network lifetime. In addition, the proposed scheme decreases both the clustering overhead and the average distance between cluster heads and their members.
Salim, Shelly; Moh, Sangman; Choi, Dongmin; Chung, Ilyong
2014-01-01
A cognitive radio sensor network (CRSN) is a wireless sensor network whose sensor nodes are equipped with cognitive radio capability. Clustering is one of the most challenging issues in CRSNs, as all sensor nodes, including the cluster head, have to use the same frequency band in order to form a cluster. However, due to the nature of heterogeneous channels in cognitive radio, it is difficult for sensor nodes to find a cluster head. This paper proposes a novel energy-efficient and compact clustering scheme named clustering with temporary support nodes (CENTRE). CENTRE efficiently achieves a compact cluster formation by adopting two-phase cluster formation with fixed duration. By introducing a novel concept of temporary support nodes to improve the cluster formation, the proposed scheme enables sensor nodes in a network to find a cluster head efficiently. The performance study shows that not only is the clustering process efficient and compact but it also results in remarkable energy savings that prolong the overall network lifetime. In addition, the proposed scheme decreases both the clustering overhead and the average distance between cluster heads and their members. PMID:25116905
Autonomous chemical and biological miniature wireless-sensor
NASA Astrophysics Data System (ADS)
Goldberg, Bar-Giora
2005-05-01
The presentation discusses a new concept and a paradigm shift in biological, chemical and explosive sensor system design and deployment. From large, heavy, centralized and expensive systems to distributed wireless sensor networks utilizing miniature platforms (nodes) that are lightweight, low cost and wirelessly connected. These new systems are possible due to the emergence and convergence of new innovative radio, imaging, networking and sensor technologies. Miniature integrated radio-sensor networks, is a technology whose time has come. These network systems are based on large numbers of distributed low cost and short-range wireless platforms that sense and process their environment and communicate data thru a network to a command center. The recent emergence of chemical and explosive sensor technology based on silicon nanostructures, coupled with the fast evolution of low-cost CMOS imagers, low power DSP engines and integrated radio chips, has created an opportunity to realize the vision of autonomous wireless networks. These threat detection networks will perform sophisticated analysis at the sensor node and convey alarm information up the command chain. Sensor networks of this type are expected to revolutionize the ability to detect and locate biological, chemical, or explosive threats. The ability to distribute large numbers of low-cost sensors over large areas enables these devices to be close to the targeted threats and therefore improve detection efficiencies and enable rapid counter responses. These sensor networks will be used for homeland security, shipping container monitoring, and other applications such as laboratory medical analysis, drug discovery, automotive, environmental and/or in-vivo monitoring. Avaak"s system concept is to image a chromatic biological, chemical and/or explosive sensor utilizing a digital imager, analyze the images and distribute alarm or image data wirelessly through the network. All the imaging, processing and communications would take place within the miniature, low cost distributed sensor platforms. This concept however presents a significant challenge due to a combination and convergence of required new technologies, as mentioned above. Passive biological and chemical sensors with very high sensitivity and which require no assaying are in development using a technique to optically and chemically encode silicon wafers with tailored nanostructures. The silicon wafer is patterned with nano-structures designed to change colors ad patterns when exposed to the target analytes (TICs, TIMs, VOC). A small video camera detects the color and pattern changes on the sensor. To determine if an alarm condition is present, an on board DSP processor, using specialized image processing algorithms and statistical analysis, determines if color gradient changes occurred on the sensor array. These sensors can detect several agents simultaneously. This system is currently under development by Avaak, with funding from DARPA through an SBIR grant.
Jiang, Joe-Air; Chuang, Cheng-Long; Lin, Tzu-Shiang; Chen, Chia-Pang; Hung, Chih-Hung; Wang, Jiing-Yi; Liu, Chang-Wang; Lai, Tzu-Yun
2010-01-01
In recent years, various received signal strength (RSS)-based localization estimation approaches for wireless sensor networks (WSNs) have been proposed. RSS-based localization is regarded as a low-cost solution for many location-aware applications in WSNs. In previous studies, the radiation patterns of all sensor nodes are assumed to be spherical, which is an oversimplification of the radio propagation model in practical applications. In this study, we present an RSS-based cooperative localization method that estimates unknown coordinates of sensor nodes in a network. Arrangement of two external low-cost omnidirectional dipole antennas is developed by using the distance-power gradient model. A modified robust regression is also proposed to determine the relative azimuth and distance between a sensor node and a fixed reference node. In addition, a cooperative localization scheme that incorporates estimations from multiple fixed reference nodes is presented to improve the accuracy of the localization. The proposed method is tested via computer-based analysis and field test. Experimental results demonstrate that the proposed low-cost method is a useful solution for localizing sensor nodes in unknown or changing environments.
Research on dual-parameter optical fiber sensor based on thin-core fiber and spherical structure
NASA Astrophysics Data System (ADS)
Tong, Zhengrong; Wang, Xue; Zhang, Weihua; Xue, Lifang
2018-04-01
A novel dual-parameter optical fiber sensor is proposed and experimentally demonstrated. The proposed sensor is based on a fiber in-line Mach-Zehnder interferometer, which is fabricated by sandwiching a section of thin-core fiber between two spherical structures made of single-mode fibers. The transmission spectrum exhibits the response of the interference between the core and the different cladding modes. Due to the different wavelength shifts of the two selected dips, the simultaneous measurement of temperature and the surrounding refractive index can be achieved. The measured temperature sensitivities are 0.067 nm/°C and 0.050 nm/°C, and the refractive index sensitivities are -119.9 nm/RIU and -69.71 nm/RIU, respectively. In addition, the compact size, simple fabrication and cost-effectiveness of the fiber sensor are also advantages.
Design and evaluation of an inexpensive radiation shield for monitoring surface air temperatures
Zachary A. Holden; Anna E. Klene; Robert F. Keefe; Gretchen G. Moisen
2013-01-01
Inexpensive temperature sensors are widely used in agricultural and forestry research. This paper describes a low-cost (~3 USD) radiation shield (radshield) designed for monitoring surface air temperatures in harsh outdoor environments. We compared the performance of the radshield paired with low-cost temperature sensors at three sites in western Montana to several...
Repurposing Radiosonde Sensors for UAV Integration
NASA Astrophysics Data System (ADS)
Clowney, F. A.
2015-12-01
Radiosondes provide accurate, high-resolution meteorological data for a variety of purposes but are inefficient for studying the atmospheric boundary layer. Tethered balloons can provide greater temporal resolution but are difficult to acquire, hard to manage and limited in vertical resolution. UAVs appear to offer a more cost-effective method for gathering low-level meteorological data in situ, with a strong possibility of adding atmospheric chemistry. This potential is enhanced by the availability of new generations of small sensors along with dramatic advances in low-cost UAVs, especially rotary-wing. InterMet is using its experience in radiosonde design and manufacturing to develop sensor packages for fixed and rotary-wing UAVs, with the goal of delivering high-quality data at low cost. The challenge is to adapt affordable, high-accuracy sensors to the different UAV flight modes. Equally important is learning from the research community what is required for this data to have useful scientific value. Specific topics to be covered include data sampling and output rates, sensor response times, calibration, sensor placement, data storage and transfer, power consumption, integration with flight management systems and wind calculations. Beta test results for the iMet-XQ and iMet-XF sensor packages will be presented if available.
Low-cost, compact, cooled photomultiplier assembly for use in magnetic fields up to 1400 Gauss
NASA Technical Reports Server (NTRS)
Patch, R. W.; Tashjian, R. A.; Jentner, T. A.
1975-01-01
Use of vortex tube for cooling and concentric shielding have produced smaller and more compact unit than was previously available. Future uses of device could include installation in gas chromatographs and mass spectrometers. Additional uses would include measurements and controls in magnetohydrodynamic power generators and fusion reactors.
A Multi-Resolution Approach for an Automated Fusion of Different Low-Cost 3D Sensors
Dupuis, Jan; Paulus, Stefan; Behmann, Jan; Plümer, Lutz; Kuhlmann, Heiner
2014-01-01
The 3D acquisition of object structures has become a common technique in many fields of work, e.g., industrial quality management, cultural heritage or crime scene documentation. The requirements on the measuring devices are versatile, because spacious scenes have to be imaged with a high level of detail for selected objects. Thus, the used measuring systems are expensive and require an experienced operator. With the rise of low-cost 3D imaging systems, their integration into the digital documentation process is possible. However, common low-cost sensors have the limitation of a trade-off between range and accuracy, providing either a low resolution of single objects or a limited imaging field. Therefore, the use of multiple sensors is desirable. We show the combined use of two low-cost sensors, the Microsoft Kinect and the David laserscanning system, to achieve low-resolved scans of the whole scene and a high level of detail for selected objects, respectively. Afterwards, the high-resolved David objects are automatically assigned to their corresponding Kinect object by the use of surface feature histograms and SVM-classification. The corresponding objects are fitted using an ICP-implementation to produce a multi-resolution map. The applicability is shown for a fictional crime scene and the reconstruction of a ballistic trajectory. PMID:24763255
A multi-resolution approach for an automated fusion of different low-cost 3D sensors.
Dupuis, Jan; Paulus, Stefan; Behmann, Jan; Plümer, Lutz; Kuhlmann, Heiner
2014-04-24
The 3D acquisition of object structures has become a common technique in many fields of work, e.g., industrial quality management, cultural heritage or crime scene documentation. The requirements on the measuring devices are versatile, because spacious scenes have to be imaged with a high level of detail for selected objects. Thus, the used measuring systems are expensive and require an experienced operator. With the rise of low-cost 3D imaging systems, their integration into the digital documentation process is possible. However, common low-cost sensors have the limitation of a trade-off between range and accuracy, providing either a low resolution of single objects or a limited imaging field. Therefore, the use of multiple sensors is desirable. We show the combined use of two low-cost sensors, the Microsoft Kinect and the David laserscanning system, to achieve low-resolved scans of the whole scene and a high level of detail for selected objects, respectively. Afterwards, the high-resolved David objects are automatically assigned to their corresponding Kinect object by the use of surface feature histograms and SVM-classification. The corresponding objects are fitted using an ICP-implementation to produce a multi-resolution map. The applicability is shown for a fictional crime scene and the reconstruction of a ballistic trajectory.
Adaptive optics with pupil tracking for high resolution retinal imaging
Sahin, Betul; Lamory, Barbara; Levecq, Xavier; Harms, Fabrice; Dainty, Chris
2012-01-01
Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics. PMID:22312577
Adaptive optics with pupil tracking for high resolution retinal imaging.
Sahin, Betul; Lamory, Barbara; Levecq, Xavier; Harms, Fabrice; Dainty, Chris
2012-02-01
Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics.
Low-cost interferometric TDM technology for dynamic sensing applications
NASA Astrophysics Data System (ADS)
Bush, Jeff; Cekorich, Allen
2004-12-01
A low-cost design approach for Time Division Multiplexed (TDM) fiber-optic interferometric interrogation of multi-channel sensor arrays is presented. This paper describes the evolutionary design process of the subject design. First, the requisite elements of interferometric interrogation are defined for a single channel sensor. The concept is then extended to multi-channel sensor interrogation implementing a TDM multiplex scheme where "traditional" design elements are utilized. The cost of the traditional TDM interrogator is investigated and concluded to be too high for entry into many markets. A new design approach is presented which significantly reduces the cost for TDM interrogation. This new approach, in accordance with the cost objectives, shows promise to bring this technology to within the threshold of commercial acceptance for a wide range of distributed fiber sensing applications.
NeXOS, developing and evaluating a new generation of insitu ocean observation systems.
NASA Astrophysics Data System (ADS)
Delory, Eric; del Rio, Joaquin; Golmen, Lars; Roar Hareide, Nils; Pearlman, Jay; Rolin, Jean-Francois; Waldmann, Christoph; Zielinski, Oliver
2017-04-01
Ocean biological, chemical or physical processes occur over widely varying scales in space and time: from micro- to kilometer scales, from less than seconds to centuries. While space systems supply important data and information, insitu data is necessary for comprehensive modeling and forecasting of ocean dynamics. Yet, collection of in-situ observation on these scales is inherently challenging and remains generally difficult and costly in time and resources. This paper address the innovations and significant developments for a new generation of insitu sensors in FP7 European Union project "Next generation, Cost- effective, Compact, Multifunctional Web Enabled Ocean Sensor Systems Empowering Marine, Maritime and Fisheries Management" or "NeXOS" for short. Optical and acoustics sensors are the focus of NeXOS but NeXOS moves beyond just sensors as systems that simultaneously address multiple objectives and applications are becoming increasingly important. Thus NeXOS takes a perspective of both sensors and sensor systems with significant advantages over existing observing capabilities via the implementation of innovations such as multiplatform integration, greater reliability through better antifouling management and greater sensor and data interoperability through use of OGC standards. This presentation will address the sensor system development and field-testing of the new NeXOS sensor systems. This is being done on multiple platforms including profiling floats, gliders, ships, buoys and subsea stations. The implementation of a data system based on SWE and PUCK furthers interoperability across measurements and platforms. This presentation will review the sensor system capabilities, the status of field tests and recommendations for long-term ocean monitoring.
Sun, Bing; Fang, Fang; Zhang, Zuxing; Xu, Jing; Zhang, Lin
2018-03-15
A high-sensitivity and low-temperature fiber-optic magnetic field sensor based on a tapered two-mode fiber (TTMF) sandwiched between two single-mode fibers has been proposed and demonstrated. The section of TTMF has a specifically designed transition region as an efficient tool to filter higher-order modes, where the uniform modal interferometer just involved with LP 01 and LP 11 modes is achieved. The transmission spectral characteristics and the magnetic response of the proposed sensors have been investigated. The experimental results show that a maximum sensitivity of 98.2 pm/Oe within a linear magnetic field intensity ranging from 0 to 140 Oe can be achieved. Significantly, the temperature cross-sensitivity problem can be resolved owing to the lower thermal expansion coefficient of the TTMF. Finally, with its low insertion loss, compactness, and ease of fabrication, the proposed sensor would find potential applications in the measurement of a magnetic field.
Sukič, Primož; Štumberger, Gorazd
2017-01-01
Clouds moving at a high speed in front of the Sun can cause step changes in the output power of photovoltaic (PV) power plants, which can lead to voltage fluctuations and stability problems in the connected electricity networks. These effects can be reduced effectively by proper short-term cloud passing forecasting and suitable PV power plant output power control. This paper proposes a low-cost Internet of Things (IoT)-based solution for intra-minute cloud passing forecasting. The hardware consists of a Raspberry PI Model B 3 with a WiFi connection and an OmniVision OV5647 sensor with a mounted wide-angle lens, a circular polarizing (CPL) filter and a natural density (ND) filter. The completely new algorithm for cloud passing forecasting uses the green and blue colors in the photo to determine the position of the Sun, to recognize the clouds, and to predict their movement. The image processing is performed in several stages, considering selectively only a small part of the photo relevant to the movement of the clouds in the vicinity of the Sun in the next minute. The proposed algorithm is compact, fast and suitable for implementation on low cost processors with low computation power. The speed of the cloud parts closest to the Sun is used to predict when the clouds will cover the Sun. WiFi communication is used to transmit this data to the PV power plant control system in order to decrease the output power slowly and smoothly. PMID:28505078
Thermal infrared reference sources fabricated from low-cost components and materials
NASA Astrophysics Data System (ADS)
Hovland, Harald; Skauli, Torbjørn
2018-04-01
Mass markets, including mobile phones and automotive sensors, drive rapid developments of imaging technologies toward high performance, low cost sensors, even for the thermal infrared. Good infrared calibration blackbody sources have remained relatively costly, however. Here we demonstrate how to make low-cost reference sources, making quantitative infrared radiometry more accessible to a wider community. Our approach uses ordinary construction materials combined with low cost microcontrollers, digital temperature sensors and foil heater elements from massmarket 3D printers. Blackbodies are constructed from a foil heater of some chosen size and shape, attached to the back of a similarly shaped aluminum plate coated with commercial black paint, which normally exhibits high emissivity. The emissivity can be readily checked by using a thermal imager to view the reflection of a hot object. A digital temperature sensor is attached to the back of the plate. Thermal isolation of the backside minimizes temperature gradients through the plate, ensuring correct readings of the front temperature. The isolation also serves to minimize convection gradients and keeps power consumption low, which is useful for battery powered operation in the field. We demonstrate surface blackbodies (200x200 mm2) with surface homogeneities as low as 0.1°C at 100°C. Homogeneous heating and low thermal mass provides for fast settling time and setup/pack-down time. The approach is scalable to larger sizes by tiling, enabling portable and foldable square-meter-size or larger devices.
Microcantilever sensor platform for UGV-based detection
NASA Astrophysics Data System (ADS)
Lawrence, Tyson T.; Halleck, A. E.; Schuler, Peter S.; Mahmud, K. K.; Hicks, David R.
2010-04-01
The increased use of Unmanned Ground Vehicles (UGVs) drives the need for new lightweight, low cost sensors. Microelectromechanical System (MEMS) based microcantilever sensors are a promising technology to meet this need, because they can be manufactured at low cost on a mass scale, and are easily integrated into a UGV platform for detection of explosives and other threat agents. While the technology is extremely sensitive, selectivity is a major challenge and the response modes are not well understood. This work summarizes advances in characterizing ultrasensitive microcantilever responses, sampling considerations, and sensor design and cantilever coating methodologies consistent with UGV point detector needs.
Cost Modeling for low-cost planetary missions
NASA Technical Reports Server (NTRS)
Kwan, Eric; Habib-Agahi, Hamid; Rosenberg, Leigh
2005-01-01
This presentation will provide an overview of the JPL parametric cost models used to estimate flight science spacecrafts and instruments. This material will emphasize the cost model approaches to estimate low-cost flight hardware, sensors, and instrumentation, and to perform cost-risk assessments. This presentation will also discuss JPL approaches to perform cost modeling and the methodologies and analyses used to capture low-cost vs. key cost drivers.
Diode laser-based air mass flux sensor for subsonic aeropropulsion inlets
NASA Astrophysics Data System (ADS)
Miller, Michael F.; Kessler, William J.; Allen, Mark G.
1996-08-01
An optical air mass flux sensor based on a compact, room-temperature diode laser in a fiber-coupled delivery system has been tested on a full-scale gas turbine engine. The sensor is based on simultaneous measurements of O 2 density and Doppler-shifted velocity along a line of sight across the inlet duct. Extensive tests spanning engine power levels from idle to full afterburner demonstrate accuracy and precision of the order of 1 2 of full scale in density, velocity, and mass flux. The precision-limited velocity at atmospheric pressure was as low as 40 cm s. Multiple data-reduction procedures are quantitatively compared to suggest optimal strategies for flight sensor packages.
Implementation of software-based sensor linearization algorithms on low-cost microcontrollers.
Erdem, Hamit
2010-10-01
Nonlinear sensors and microcontrollers are used in many embedded system designs. As the input-output characteristic of most sensors is nonlinear in nature, obtaining data from a nonlinear sensor by using an integer microcontroller has always been a design challenge. This paper discusses the implementation of six software-based sensor linearization algorithms for low-cost microcontrollers. The comparative study of the linearization algorithms is performed by using a nonlinear optical distance-measuring sensor. The performance of the algorithms is examined with respect to memory space usage, linearization accuracy and algorithm execution time. The implementation and comparison results can be used for selection of a linearization algorithm based on the sensor transfer function, expected linearization accuracy and microcontroller capacity. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The feasibility of using a compact, low-cost NIR spectrophotometer to predict moisture (MC) and total fat content of minced pork was demonstrated. Results were compared with those obtained using two research type instruments with high signal to noise ratio (S/N). The NIR measuring head of the compac...
Dong, Lei; Li, Chunguang; Sanchez, Nancy P.; ...
2016-01-05
A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that themore » measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei; Li, Chunguang; Sanchez, Nancy P.
A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that themore » measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.« less
Evaluating the performance of low cost chemical sensors for air pollution research.
Lewis, Alastair C; Lee, James D; Edwards, Peter M; Shaw, Marvin D; Evans, Mat J; Moller, Sarah J; Smith, Katie R; Buckley, Jack W; Ellis, Matthew; Gillot, Stefan R; White, Andrew
2016-07-18
Low cost pollution sensors have been widely publicized, in principle offering increased information on the distribution of air pollution and a democratization of air quality measurements to amateur users. We report a laboratory study of commonly-used electrochemical sensors and quantify a number of cross-interferences with other atmospheric chemicals, some of which become significant at typical suburban air pollution concentrations. We highlight that artefact signals from co-sampled pollutants such as CO2 can be greater than the electrochemical sensor signal generated by the measurand. We subsequently tested in ambient air, over a period of three weeks, twenty identical commercial sensor packages alongside standard measurements and report on the degree of agreement between references and sensors. We then explore potential experimental approaches to improve sensor performance, enhancing outputs from qualitative to quantitative, focusing on low cost VOC photoionization sensors. Careful signal handling, for example, was seen to improve limits of detection by one order of magnitude. The quantity, magnitude and complexity of analytical interferences that must be characterised to convert a signal into a quantitative observation, with known uncertainties, make standard individual parameter regression inappropriate. We show that one potential solution to this problem is the application of supervised machine learning approaches such as boosted regression trees and Gaussian processes emulation.
Characterization of a Low-Cost Multi-Parameter Sensor for Resource Applications: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron M; Sengupta, Manajit; Andreas, Afshin M
Low-cost multi-parameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electrical grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed Arable Lab's Mark multi-parameter sensor system. The unique suite of system sensors measures the down-welling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. This study describes the shortwave calibration, characteriza-tion, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.
A Compact Inductive Position Sensor Made by Inkjet Printing Technology on a Flexible Substrate
Jeranče, Nikola; Vasiljević, Dragana; Samardžić, Nataša; Stojanović, Goran
2012-01-01
This paper describes the design, simulation and fabrication of an inductive angular position sensor on a flexible substrate. The sensor is composed of meandering silver coils printed on a flexible substrate (Kapton film) using inkjet technology. The flexibility enables that after printing in the plane, the coils could be rolled and put inside each other. By changing the angular position of the internal coil (rotor) related to the external one (stator), the mutual inductance is changed and consequently the impedance. It is possible to determine the angular position from the measured real and imaginary part of the impedance, in our case in the frequency range from 1 MHz to 10 MHz. Experimental results were compared with simulation results obtained by in-house developed software tool, and very good agreement has been achieved. Thanks to the simple design and fabrication, smaller package space requirements and weight, the presented sensor represents a cost-effective alternative to the other sensors currently used in series production applications. PMID:22438710
Compact instrument for fluorescence image-guided surgery
NASA Astrophysics Data System (ADS)
Wang, Xinghua; Bhaumik, Srabani; Li, Qing; Staudinger, V. Paul; Yazdanfar, Siavash
2010-03-01
Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.
Redondo, Jonatan Pajares; González, Lisardo Prieto; Guzman, Javier García; Boada, Beatriz L; Díaz, Vicente
2018-02-06
Nowadays, the current vehicles are incorporating control systems in order to improve their stability and handling. These control systems need to know the vehicle dynamics through the variables (lateral acceleration, roll rate, roll angle, sideslip angle, etc.) that are obtained or estimated from sensors. For this goal, it is necessary to mount on vehicles not only low-cost sensors, but also low-cost embedded systems, which allow acquiring data from sensors and executing the developed algorithms to estimate and to control with novel higher speed computing. All these devices have to be integrated in an adequate architecture with enough performance in terms of accuracy, reliability and processing time. In this article, an architecture to carry out the estimation and control of vehicle dynamics has been developed. This architecture was designed considering the basic principles of IoT and integrates low-cost sensors and embedded hardware for orchestrating the experiments. A comparison of two different low-cost systems in terms of accuracy, acquisition time and reliability has been done. Both devices have been compared with the VBOX device from Racelogic, which has been used as the ground truth. The comparison has been made from tests carried out in a real vehicle. The lateral acceleration and roll rate have been analyzed in order to quantify the error of these devices.
Díaz, Vicente
2018-01-01
Nowadays, the current vehicles are incorporating control systems in order to improve their stability and handling. These control systems need to know the vehicle dynamics through the variables (lateral acceleration, roll rate, roll angle, sideslip angle, etc.) that are obtained or estimated from sensors. For this goal, it is necessary to mount on vehicles not only low-cost sensors, but also low-cost embedded systems, which allow acquiring data from sensors and executing the developed algorithms to estimate and to control with novel higher speed computing. All these devices have to be integrated in an adequate architecture with enough performance in terms of accuracy, reliability and processing time. In this article, an architecture to carry out the estimation and control of vehicle dynamics has been developed. This architecture was designed considering the basic principles of IoT and integrates low-cost sensors and embedded hardware for orchestrating the experiments. A comparison of two different low-cost systems in terms of accuracy, acquisition time and reliability has been done. Both devices have been compared with the VBOX device from Racelogic, which has been used as the ground truth. The comparison has been made from tests carried out in a real vehicle. The lateral acceleration and roll rate have been analyzed in order to quantify the error of these devices. PMID:29415507
Compact Full-Field Ion Detector System for CubeSat Science Beyond LEO
NASA Technical Reports Server (NTRS)
Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.; Clark, Pamela E.
2013-01-01
NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop a Compact Full-Field Ion Detector System (CFIDS). The CFIDS is designed to be an extremely compact, low cost instrument, capable of being flown on a wide variety of deep space platforms, to provide comprehensive (composition, velocity, and direction) in situ measurements of heavy ions in space plasma environments with higher fidelity, than previously available.
SpiderSpec: a low-cost compact colorimeter with IoT functionality
NASA Astrophysics Data System (ADS)
Mignani, Anna G.; Mencaglia, Andrea A.; Baldi, Massimo; Ciaccheri, Leonardo
2015-07-01
A miniaturized device for colorimetry is presented that utilizes a LED array for illumination and a compact spectrometer for detection. It can be battery-powered, operated locally as a stand-alone device, or connected via wi-fi to the internet. It has potentials to be remotely operated by means of a tablet or a smartphone. In practice, it consists of a low-cost hardware configuration that is adaptable via software to the user's most varied requests, as a spectroscopic platform appropriate for a variety of applications. The hardware and software modules can be designed with different performances, complexities and costs, with the aim of making the colorimeter a device for Internet-of-Things use. It will be suitable for a selected range of consumer applications, as well as for targeted industrial, environmental, and food applications.
Clustering approaches to improve the performance of low cost air pollution sensors.
Smith, Katie R; Edwards, Peter M; Evans, Mathew J; Lee, James D; Shaw, Marvin D; Squires, Freya; Wilde, Shona; Lewis, Alastair C
2017-08-24
Low cost air pollution sensors have substantial potential for atmospheric research and for the applied control of pollution in the urban environment, including more localized warnings to the public. The current generation of single-chemical gas sensors experience degrees of interference from other co-pollutants and have sensitivity to environmental factors such as temperature, wind speed and supply voltage. There are uncertainties introduced also because of sensor-to-sensor response variability, although this is less well reported. The sensitivity of Metal Oxide Sensors (MOS) to volatile organic compounds (VOCs) changed with relative humidity (RH) by up to a factor of five over the range of 19-90% RH and with an uncertainty in the correction of a factor of two at any given RH. The short-term (second to minute) stabilities of MOS and electrochemical CO sensor responses were reasonable. During more extended use, inter-sensor quantitative comparability was degraded due to unpredictable variability in individual sensor responses (to either measurand or interference or both) drifting over timescales of several hours to days. For timescales longer than a week identical sensors showed slow, often downwards, drifts in their responses which diverged across six CO sensors by up to 30% after two weeks. The measurement derived from the median sensor within clusters of 6, 8 and up to 21 sensors was evaluated against individual sensor performance and external reference values. The clustered approach maintained the cost competitiveness of a sensor device, but the median concentration from the ensemble of sensor signals largely eliminated the randomised hour-to-day response drift seen in individual sensors and excluded the effects of small numbers of poorly performing sensors that drifted significantly over longer time periods. The results demonstrate that for individual sensors to be optimally comparable to one another, and to reference instruments, they would likely require frequent calibration. The use of a cluster median value eliminates unpredictable medium term response changes, and other longer term outlier behaviours, extending the likely period needed between calibration and making a linear interpolation between calibrations more appropriate. Through the use of sensor clusters rather than individual sensors, existing low cost technologies could deliver significantly improved quality of observations.
Multifunctional Web Enabled Ocean Sensor Systems for the Monitoring of a Changing Ocean
NASA Astrophysics Data System (ADS)
Pearlman, Jay; Castro, Ayoze; Corrandino, Luigi; del Rio, Joaquin; Delory, Eric; Garello, Rene; Heuermann, Rudinger; Martinez, Enoc; Pearlman, Francoise; Rolin, Jean-Francois; Toma, Daniel; Waldmann, Christoph; Zielinski, Oliver
2016-04-01
As stated in the 2010 "Ostend Declaration", a major challenge in the coming years is the development of a truly integrated and sustainably funded European Ocean Observing System for supporting major policy initiatives such as the Integrated Maritime Policy and the Marine Strategy Framework Directive. This will be achieved with more long-term measurements of key parameters supported by a new generation of sensors whose costs and reliability will enable broad and consistent observations. Within the NeXOS project, a framework including new sensors capabilities and interface software has been put together that embraces the key technical aspects needed to improve the temporal and spatial coverage, resolution and quality of marine observations. The developments include new, low-cost, compact and integrated sensors with multiple functionalities that will allow for the measurements useful for a number of objectives, ranging from more precise monitoring and modeling of the marine environment to an improved assessment of fisheries. The project is entering its third year and will be demonstrating initial capabilities of optical and acoustic sensor prototypes that will become available for a number of platforms. For fisheries management, there is also a series of sensors that support an Ecosystem Approach to Fisheries (EAF). The greatest capabilities for comprehensive operations will occur when these sensors can be integrated into a multisensory capability on a single platform or multiply interconnected and coordinated platforms. Within NeXOS the full processing steps starting from the sensor signal all the way up to distributing collected environmental information will be encapsulated into standardized new state of the art Smart Sensor Interface and Web components to provide both improved integration and a flexible interface for scientists to control sensor operation. The use of the OGC SWE (Sensor Web Enablement) set of standards like OGC PUCK and SensorML at the instrument to platform integration phase will provide standard mechanisms for a truly plug'n'work connection. Through this, NeXOS Instruments will maintain within themselves specific information about how a platform (buoy controller, AUV controller, Observatory controller) has to configure and communicate with the instrument without the platform needing previous knowledge about the instrument. This mechanism is now being evaluated in real platforms like a Slocum Glider from Teledyne Web research, SeaExplorer Glider from Alseamar, Provor Float from NKE, and others including non commercial platforms like Obsea seafloor cabled observatory. The latest developments in the NeXOS sensors and the integration into an observation system will be discussed, addressing demonstration plans both for a variety of platforms and scientific objectives supporting marine management.
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A.
2016-01-01
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with “open” digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions. PMID:27089377
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms.
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A
2016-04-14
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with "open" digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions.
Development of a high-speed wavelength-agile CO2 local oscillator for heterodyne DIAL measurements
NASA Astrophysics Data System (ADS)
Senft, Daniel C.; Pierrottet, Diego F.
2002-06-01
A high repetition rate, wavelength agile CO2 laser has been developed at the Air Force Research Laboratory for use as a local oscillator in a heterodyne detection receiver. Fats wavelength selection is required for measurements of airborne chemical vapors using the differential absorption lidar (DIAL) technique. Acousto-optic modulator are used to tune between different wavelengths at high speeds without the need for moving mechanical parts. Other advantages obtained by the use of acousto-optic modulators are laser output power control per wavelength and rugged packaging for field applications. The local oscillator design is described, and the results from laboratory DIAL measurements are presented. The coherent remote optical sensor system is an internal research project being conducted by the Air Force Research Laboratory Directed Energy Directorate, Active Remote Sensing Branch. The objective of the project is to develop a new long-range standoff spectral sensor that takes advantage of the enhanced performance capabilities coherent detection can provide. Emphasis of the development is on a low cost, compact, and rugged active sensor exclusively designed for heterodyne detection using the differential absorption lidar technique. State of the art technologies in waveguide laser construction and acousto- optics make feasible the next generation of lasers capable of supporting coherent lidar system requirements. Issues addressed as part of the development include optoelectronic engineering of a low cost rugged system, and fast data throughput for real time chemical concentration measurements. All hardware used in this sensor are off-the- shelf items, so only minor hardware modifications were required for the system as it stands. This paper describes a high-speed heterodyne detection CO2 DIAL system that employs a wavelength agile, acousto-optically tuned local oscillator in the receiver. Sample experimental data collected in a controlled environment are presented as well. Chemical detection using 12 wavelengths at 200 pulses per second has been demonstrated. Initial progress on experiments to make a direct, simultaneous comparison of heterodyne and direct detection DIAL systems will also be described.
Performance of a fire detector based on a compact laser spectroscopic carbon monoxide sensor.
Hangauer, A; Chen, J; Strzoda, R; Fleischer, M; Amann, M-C
2014-06-02
In this paper we show the suitability of a miniaturized tunable diode laser spectroscopy (TDLS)-based carbon-monoxide (CO) sensor for fire detection applications. The sensor utilizes a vertical-cavity surface-emitting laser (VCSEL) and inherent calibration scheme with reference gas filled in the photodetector housing. The fire-detection experiments are carried out under realistic conditions as described in the European standard EN54. The CO generation of all class C fires (according to EN54) could be well resolved. The cross-sensitivity to other substances was found to be very low: the maximum CO false response from cigarette smoke, hairspray and general aerosols reaches a low value of a few μL/L and only if the substance is directly applied into the sensor gas inlet. Therefore this sensor overcomes the disadvantage of high false alarm rate given by smoke detectors and is also in small size which is suitable for household and industrial applications. Hence, the VCSEL-based TDLS sensor is shown to have sufficient performance for fire-detection. It has advantages such as capability for fail-safe operation and, low cross-sensitivities as compared to existing point fire detector technology which is presently limited by these factors.
NASA Astrophysics Data System (ADS)
Gunawardena, N.; Pardyjak, E. R.; Stoll, R.; Khadka, A.
2018-02-01
Over the last decade there has been a proliferation of low-cost sensor networks that enable highly distributed sensor deployments in environmental applications. The technology is easily accessible and rapidly advancing due to the use of open-source microcontrollers. While this trend is extremely exciting, and the technology provides unprecedented spatial coverage, these sensors and associated microcontroller systems have not been well evaluated in the literature. Given the large number of new deployments and proposed research efforts using these technologies, it is necessary to quantify the overall instrument and microcontroller performance for specific applications. In this paper, an Arduino-based weather station system is presented in detail. These low-cost energy-budget measurement stations, or LEMS, have now been deployed for continuous measurements as part of several different field campaigns, which are described herein. The LEMS are low-cost, flexible, and simple to maintain. In addition to presenting the technical details of the LEMS, its errors are quantified in laboratory and field settings. A simple artificial neural network-based radiation-error correction scheme is also presented. Finally, challenges and possible improvements to microcontroller-based atmospheric sensing systems are discussed.
Costa, Tiago; Cardoso, Filipe A; Germano, Jose; Freitas, Paulo P; Piedade, Moises S
2017-10-01
The development of giant magnetoresistive (GMR) sensors has demonstrated significant advantages in nanomedicine, particularly for ultrasensitive point-of-care diagnostics. To this end, the detection system is required to be compact, portable, and low power consuming at the same time that a maximum signal to noise ratio is maintained. This paper reports a CMOS front-end with integrated magnetoresistive sensors for biomolecular recognition detection applications. Based on the characterization of the GMR sensor's signal and noise, CMOS building blocks (i.e., current source, multiplexers, and preamplifier) were designed targeting a negligible noise when compared with the GMR sensor's noise and a low power consumption. The CMOS front-end was fabricated using AMS [Formula: see text] technology and the magnetoresistive sensors were post-fabricated on top of the CMOS chip with high yield ( [Formula: see text]). Due to its low circuit noise (16 [Formula: see text]) and overall equivalent magnetic noise ([Formula: see text]), the full system was able to detect 250 nm magnetic nanoparticles with a circuit imposed signal-to-noise ratio degradation of only -1.4 dB. Furthermore, the low power consumption (6.5 mW) and small dimensions ([Formula: see text] ) of the presented solution guarantees the portability of the detection system allowing its usage at the point-of-care.
Ceramic MEMS Designed for Wireless Pressure Monitoring in the Industrial Environment
Pavlin, Marko; Belavic, Darko; Novak, Franc
2012-01-01
This paper presents the design of a wireless pressure-monitoring system for harsh-environment applications. Two types of ceramic pressure sensors made with a low-temperature cofired ceramic (LTCC) were considered. The first type is a piezoresistive strain gauge pressure sensor. The second type is a capacitive pressure sensor, which is based on changes of the capacitance values between two electrodes: one electrode is fixed and the other is movable under an applied pressure. The design was primarily focused on low power consumption. Reliable operation in the presence of disturbances, like electromagnetic interference, parasitic capacitances, etc., proved to be contradictory constraints. A piezoresistive ceramic pressure sensor with a high bridge impedance was chosen for use in a wireless pressure-monitoring system and an acceptable solution using energy-harvesting techniques has been achieved. The described solution allows for the integration of a sensor element with an energy harvester that has a printed thick-film battery and complete electronics in a single substrate packaged inside a compact housing. PMID:22368471
Solid State pH Sensor Based on Light Emitting Diodes (LED) As Detector Platform
Lau, King Tong; Shepherd, R.; Diamond, Danny; Diamond, Dermot
2006-01-01
A low-power, high sensitivity, very low-cost light emitting diode (LED)-based device developed for low-cost sensor networks was modified with bromocresol green membrane to work as a solid-state pH sensor. In this approach, a reverse-biased LED functioning as a photodiode is coupled with a second LED configured in conventional emission mode. A simple timer circuit measures how long (in microsecond) it takes for the photocurrent generated on the detector LED to discharge its capacitance from logic 1 (+5 V) to logic 0 (+1.7 V). The entire instrument provides an inherently digital output of light intensity measurements for a few cents. A light dependent resistor (LDR) modified with similar sensor membrane was also used as a comparison method. Both the LED sensor and the LDR sensor responded to various pH buffer solutions in a similar way to obtain sigmoidal curves expected of the dye. The pKa value obtained for the sensors was found to agree with the literature value.
NASA Technical Reports Server (NTRS)
2015-01-01
Topics covered include: 3D Endoscope to Boost Safety, Cut Cost of Surgery; Audio App Brings a Better Night's Sleep Liquid Cooling Technology Increases Exercise Efficiency; Algae-Derived Dietary Ingredients Nourish Animals; Space Grant Research Launches Rehabilitation Chair; Vision Trainer Teaches Focusing Techniques at Home; Aircraft Geared Architecture Reduces Fuel Cost and Noise; Ubiquitous Supercritical Wing Design Cuts Billions in Fuel Costs; Flight Controller Software Protects Lightweight Flexible Aircraft; Cabin Pressure Monitors Notify Pilots to Save Lives; Ionospheric Mapping Software Ensures Accuracy of Pilots' GPS; Water Mapping Technology Rebuilds Lives in Arid Regions; Shock Absorbers Save Structures and Lives during Earthquakes; Software Facilitates Sharing of Water Quality Data Worldwide; Underwater Adhesives Retrofit Pipelines with Advanced Sensors; Laser Imaging Video Camera Sees through Fire, Fog, Smoke; 3D Lasers Increase Efficiency, Safety of Moving Machines; Air Revitalization System Enables Excursions to the Stratosphere; Magnetic Fluids Deliver Better Speaker Sound Quality; Bioreactor Yields Extracts for Skin Cream; Private Astronaut Training Prepares Commercial Crews of Tomorrow; Activity Monitors Help Users Get Optimum Sun Exposure; LEDs Illuminate Bulbs for Better Sleep, Wake Cycles; Charged Particles Kill Pathogens and Round Up Dust; Balance Devices Train Golfers for a Consistent Swing; Landsat Imagery Enables Global Studies of Surface Trends; Ruggedized Spectrometers Are Built for Tough Jobs; Gas Conversion Systems Reclaim Fuel for Industry; Remote Sensing Technologies Mitigate Drought; Satellite Data Inform Forecasts of Crop Growth; Probes Measure Gases for Environmental Research; Cloud Computing Technologies Facilitate Earth Research; Software Cuts Homebuilding Costs, Increases Energy Efficiency; Portable Planetariums Teach Science; Schedule Analysis Software Saves Time for Project Planners; Sound Modeling Simplifies Vehicle Noise Management; Custom 3D Printers Revolutionize Space Supply Chain; Improved Calibration Shows Images' True Colors; Micromachined Parts Advance Medicine, Astrophysics, and More; Metalworking Techniques Unlock a Unique Alloy; Low-Cost Sensors Deliver Nanometer-Accurate Measurements; Electrical Monitoring Devices Save on Time and Cost; Dry Lubricant Smooths the Way for Space Travel, Industry; and Compact Vapor Chamber Cools Critical Components.
Toward the Realization of a Compact Chemical Sensor Platform using Quantum Cascade Lasers
2015-09-01
bromide (KBr) beamsplitter and a mercury cadmium telluride ( MCT )-A (narrow band – 650 cm-1 cutoff) detector . Each spectrum was acquired at a resolution...focuses on increasing speed, sensitivity, and selectivity, while reducing size and cost. Although the current state-of-the-art vapor detector (Joint...Chemical Agent Detector (JCAD)) is lightweight, handheld, and easily attaches to a belt, it still provides added bulk to a soldier on foot patrol. Both
Combined reflection and transmission microscope for telemedicine applications in field settings.
Biener, Gabriel; Greenbaum, Alon; Isikman, Serhan O; Lee, Kelvin; Tseng, Derek; Ozcan, Aydogan
2011-08-21
We demonstrate a field-portable upright and inverted microscope that can image specimens in both reflection and transmission modes. This compact and cost-effective dual-mode microscope weighs only ∼135 grams (<4.8 ounces) and utilizes a simple light emitting diode (LED) to illuminate the sample of interest using a beam-splitter cube that is positioned above the object plane. This LED illumination is then partially reflected from the sample to be collected by two lenses, creating a reflection image of the specimen onto an opto-electronic sensor-array that is positioned above the beam-splitter cube. In addition to this, the illumination beam is also partially transmitted through the same specimen, which then casts lensfree in-line holograms of the same objects onto a second opto-electronic sensor-array that is positioned underneath the beam-splitter cube. By rapid digital reconstruction of the acquired lensfree holograms, transmission images (both phase and amplitude) of the same specimen are also created. We tested the performance of this field-portable microscope by imaging various micro-particles, blood smears as well as a histopathology slide corresponding to skin tissue. Being compact, light-weight and cost-effective, this combined reflection and transmission microscope might especially be useful for telemedicine applications in resource limited settings. This journal is © The Royal Society of Chemistry 2011
NASA Astrophysics Data System (ADS)
Pachava, Vengal Rao; Kamineni, Srimannarayana; Madhuvarasu, Sai Shankar; Putha, Kishore; Mamidi, Venkata Reddy
2015-12-01
A fiber Bragg grating (FBG) pressure sensor with high sensitivity and resolution has been designed and demonstrated. The sensor is configured by firmly fixing the FBG with a metal bellows structure. The sensor works by means of measuring the Bragg wavelength shift of the FBG with respect to pressure change. From the experimental results, the pressure sensitivity of the sensor is found to be 90.6 pm/psi, which is approximately 4000 times as that of a bare fiber Bragg grating. A very good linearity of 99.86% is observed between the Bragg wavelength of the FBG and applied pressure. The designed sensor shows good repeatability with a negligible hysteresis error of ± 0.29 psi. A low-cost interrogation system that includes a long period grating (LPG) and a photodiode (PD) accompanied with simple electronic circuitry is demonstrated for the FBG sensor, which enables the sensor to attain high resolution of up to 0.025 psi. Thermal-strain cross sensitivity of the FBG pressure sensor is compensated using a reference FBG temperature sensor. The designed sensor can be used for liquid level, specific gravity, and static/dynamic low pressure measurement applications.
The Compact Environmental Anomaly Sensor (CEASE) III
NASA Astrophysics Data System (ADS)
Roddy, P.; Hilmer, R. V.; Ballenthin, J.; Lindstrom, C. D.; Barton, D. A.; Ignazio, J. M.; Coombs, J. M.; Johnston, W. R.; Wheelock, A. T.; Quigley, S.
2016-12-01
The Air Force Research Laboratory's Energetic Charged Particle (ECP) sensor project is a comprehensive effort to measure the charged particle environment that causes satellite anomalies. The project includes the Compact Environmental Anomaly Sensor (CEASE) III, building on the flight heritage of prior CEASE designs. CEASE III consists of multiple sensor modules. High energy particles are observed using independent unique silicon detector stacks. In addition CEASE III includes an electrostatic analyzer (ESA) assembly which uses charge multiplication for particle detection. The sensors cover a wide range of proton and electron energies that contribute to satellite anomalies.
Portable equipment for determining ripeness in Hass avocado using a low cost color sensor
NASA Astrophysics Data System (ADS)
Toro, Jessica; Daza, Carolina; Vega, Fabio; Diaz, Leonardo; Torres, Cesar
2015-08-01
The avocado is a one climacteric fruit that not ripe on the tree because it produces a maturation inhibitor that passes the fruit through the pedicel, the ripening occurs naturally during storage or to be induced as required. In post-harvest ripening stage is basically determined by experience of the farmer or buyer. In this word us developed portable equipment for determining ripeness is hass avocado using a low cost sensor color sensor TC3200 and LCD for display result. The prototype read of RGB color frequencies of the sensor and estimates the stage of ripeness in fourth different stages in post-harvest ripening.
A Low Cost Sensor Controller for Health Monitoring
NASA Astrophysics Data System (ADS)
Birbas, M.; Petrellis, N.; Gioulekas, F.
2015-09-01
Aging population can benefit from health care systems that allow their health and daily life to be monitored by expert medical staff. Blood pressure, temperature measurements or more advanced tests like Electrocardiograms (ECG) can be ordered through such a healthcare system while urgent situations can be detected and alleviated on time. The results of these tests can be stored with security in a remote cloud or database. Such systems are often used to monitor non-life threatening patient health problems and their advantage in lowering the cost of the healthcare services is obvious. A low cost commercial medical sensor kit has been used in the present work, trying to improve the accuracy and stability of the sensor measurements, the power consumption, etc. This Sensor Controller communicates with a Gateway installed in the patient's residence and a tablet or smart phone used for giving instructions to the patient through a comprehensive user interface. A flexible communication protocol has been defined supporting any short or long term sensor sampling scenario. The experimental results show that it is possible to achieve low power consumption by applying apropriate sleep intervals to the Sensor Controller and by deactivating periodically some of its functionality.
NASA Technical Reports Server (NTRS)
Alonso, Jesus Delgado; Phillips, Straun; Chullen, Cinda; Mendoza, Edgar
2014-01-01
Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench-top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under conditions of water condensation. This paper presents the most recent progress in the development of this sensor technology. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the space suit, and this complexity may interfere with gas sensor readings. This paper presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in space suits. A study of the calibration stability of the sensors is also presented. For that purpose, a profile of temperature, pressure, humidity, and gas composition for the duration of an EVA has been defined, and the performance of sensors operated repeatedly under those conditions has been studied. Finally, this paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a PLSS.
Eddy-current non-inertial displacement sensing for underwater infrasound measurements.
Donskoy, Dimitri M; Cray, Benjamin A
2011-06-01
A non-inertial sensing approach for an Acoustic Vector Sensor (AVS), which utilizes eddy-current displacement sensors and operates well at Ultra-Low Frequencies (ULF), is described here. In the past, most ULF measurements (from mHertz to approximately 10 Hertz) have been conducted using heavy geophones or seismometers that must be installed on the seafloor; these sensors are not suitable for water column measurements. Currently, there are no readily available compact and affordable underwater AVS that operate within this frequency region. Test results have confirmed the validity of the proposed eddy-current AVS design and have demonstrated high acoustic sensitivity. © 2011 Acoustical Society of America
Air-Microfluidics: Creating Small, Low-cost, Portable Air Quality Sensors
Air-microfluidics shows great promise in dramatically reducing the size, cost, and power requirements of future air quality sensors without compromising their accuracy. Microfabrication provides a suite of relatively new tools for the development of micro electro mechanical syste...
NASA Technical Reports Server (NTRS)
2001-01-01
A Small Business Innovation Research (SBIR) sponsorship from NASA's Dryden Flight Research Center, assisted MetroLaser, of Irvine, California, in the development of a self-aligned laser vibrometer system. VibroMet, capable of measuring surface vibrations in a variety of industries, provides information on the structural integrity and acoustical characteristics of manufactured products. This low-cost, easy-to-use sensor performs vibration measurement from distances of up to three meters without the need for adjustment. The laser beam is simply pointed at the target and the system then uses a compact laser diode to illuminate the surface and to subsequently analyze the reflected light. The motion of the surface results in a Doppler shift that is measured with very high precision. VibroMet is considered one of the many behind-the-scenes tools that can be relied on to assure the quality, reliability and safety of everything from airplane panels to disk brakes
Short time interval comparisons of low cost sensor response and corresponding Federal Reference or Federal Equivalent Monitors at an NCOR site located in proximity to Atlanta, GeorgiaThis dataset is associated with the following publication:Jiao, W., G. Hagler, R. Williams, R. Sharpe, R. Brown, D. Garver, R. Judge, M. Caudill, J. Rickard, M. Davis, L. Weinstock, S. Zimmer-Dauphinee, and K. Buckley. Community Air Sensor Network (CAIRSENSE) project: Evaluation of low-cost sensor performance in a suburban environment in the southeastern United States. Atmospheric Measurement Techniques. Copernicus Publications, Katlenburg-Lindau, GERMANY, 9: 5282-5292, (2016).
Path to Market for Compact Modular Fusion Power Cores
NASA Astrophysics Data System (ADS)
Woodruff, Simon; Baerny, Jennifer K.; Mattor, Nathan; Stoulil, Don; Miller, Ronald; Marston, Theodore
2012-08-01
The benefits of an energy source whose reactants are plentiful and whose products are benign is hard to measure, but at no time in history has this energy source been more needed. Nuclear fusion continues to promise to be this energy source. However, the path to market for fusion systems is still regularly a matter for long-term (20 + year) plans. This white paper is intended to stimulate discussion of faster commercialization paths, distilling guidance from investors, utilities, and the wider energy research community (including from ARPA-E). There is great interest in a small modular fusion system that can be developed quickly and inexpensively. A simple model shows how compact modular fusion can produce a low cost development path by optimizing traditional systems that burn deuterium and tritium, operating not only at high magnetic field strength, but also by omitting some components that allow for the core to become more compact and easier to maintain. The dominant hurdles to the development of low cost, practical fusion systems are discussed, primarily in terms of the constraints placed on the cost of development stages in the private sector. The main finding presented here is that the bridge from DOE Office of Science to the energy market can come at the Proof of Principle development stage, providing the concept is sufficiently compact and inexpensive that its development allows for a normal technology commercialization path.
Nabovati, Ghazal; Ghafar-Zadeh, Ebrahim; Letourneau, Antoine; Sawan, Mohamad
2017-04-01
In this paper we present a CMOS capacitive sensor array as a compact and low-cost platform for high-throughput cell growth monitoring. The proposed biosensor, consists of an array of 8 × 8 CMOS fully differential charge-based capacitive measurement sensors. A DC-input Σ∆ modulator is used to convert the sensors' signals to digital values for reading out the biological/chemical data and further signal processing. To compensate the mismatch variations between the current mirror transistors, a calibration circuitry is proposed which removes the output voltage offset with less than 8.2% error. We validate the chip functionality using various organic solvents with different dielectric constants. Moreover, we show the response of the chip to different concentrations of Polystyrene beads that have the same electrical properties as the living cells. The experimental results show that the chip allows the detection of a wide range of Polystyrene beads concentrations from as low as 10 beads/ml to 100 k beads/ml. In addition, we present the experimental results from H1299 (human lung carcinoma) cell line where we show that the chip successfully allows the detection of cell attachment and growth over capacitive electrodes in a 30 h measurement time and the results are in consistency with the standard cell-based assays. The capability of proposed device for label-free and real-time detection of cell growth with very high sensitivity opens up the important opportunity for utilizing the device in rapid screening of living cells.
Surface acoustic wave devices for sensor applications
NASA Astrophysics Data System (ADS)
Bo, Liu; Xiao, Chen; Hualin, Cai; Mohammad, Mohammad Ali; Xiangguang, Tian; Luqi, Tao; Yi, Yang; Tianling, Ren
2016-02-01
Surface acoustic wave (SAW) devices have been widely used in different fields and will continue to be of great importance in the foreseeable future. These devices are compact, cost efficient, easy to fabricate, and have a high performance, among other advantages. SAW devices can work as filters, signal processing units, sensors and actuators. They can even work without batteries and operate under harsh environments. In this review, the operating principles of SAW sensors, including temperature sensors, pressure sensors, humidity sensors and biosensors, will be discussed. Several examples and related issues will be presented. Technological trends and future developments will also be discussed. Project supported by the National Natural Science Foundation of China (Nos. 60936002, 61025021, 61434001, 61574083), the State Key Development Program for Basic Research of China (No. 2015CB352100), the National Key Project of Science and Technology (No. 2011ZX02403-002) and the Special Fund for Agroscientific Research in the Public Interest of China (No. 201303107). M.A.M is additionally supported by the Postdoctoral Fellowship (PDF) program of the Natural Sciences and Engineering Research Council (NSERC) of Canada and the China Postdoctoral Science Foundation (CPSF).
Integration of Kinect and Low-Cost Gnss for Outdoor Navigation
NASA Astrophysics Data System (ADS)
Pagliaria, D.; Pinto, L.; Reguzzoni, M.; Rossi, L.
2016-06-01
Since its launch on the market, Microsoft Kinect sensor has represented a great revolution in the field of low cost navigation, especially for indoor robotic applications. In fact, this system is endowed with a depth camera, as well as a visual RGB camera, at a cost of about 200. The characteristics and the potentiality of the Kinect sensor have been widely studied for indoor applications. The second generation of this sensor has been announced to be capable of acquiring data even outdoors, under direct sunlight. The task of navigating passing from an indoor to an outdoor environment (and vice versa) is very demanding because the sensors that work properly in one environment are typically unsuitable in the other one. In this sense the Kinect could represent an interesting device allowing bridging the navigation solution between outdoor and indoor. In this work the accuracy and the field of application of the new generation of Kinect sensor have been tested outdoor, considering different lighting conditions and the reflective properties of the emitted ray on different materials. Moreover, an integrated system with a low cost GNSS receiver has been studied, with the aim of taking advantage of the GNSS positioning when the satellite visibility conditions are good enough. A kinematic test has been performed outdoor by using a Kinect sensor and a GNSS receiver and it is here presented.
Low-Cost Fiber Optic Pressure Sensor
Sheem, Sang K.
2004-05-18
The size and cost of fabricating fiber optic pressure sensors is reduced by fabricating the membrane of the sensor in a non-planar shape. The design of the sensors may be made in such a way that the non-planar membrane becomes a part of an air-tight cavity, so as to make the membrane resilient due to the air-cushion effect of the air-tight cavity. Such non-planar membranes are easier to make and attach.
Low-Cost Fiber Optic Pressure Sensor
Sheem, Sang K.
2003-07-22
The size and cost of fabricating fiber optic pressure sensors is reduced by fabricating the membrane of the sensor in a non-planar shape. The design of the sensors may be made in such a way that the non-planar membrane becomes a part of an air-tight cavity, so as to make the membrane resilient due to the air-cushion effect of the air-tight cavity. Such non-planar membranes are easier to make and attach.
Low Cost and Flexible UAV Deployment of Sensors
Sørensen, Lars Yndal; Jacobsen, Lars Toft; Hansen, John Paulin
2017-01-01
This paper presents a platform for airborne sensor applications using low-cost, open-source components carried by an easy-to-fly unmanned aircraft vehicle (UAV). The system, available in open-source , is designed for researchers, students and makers for a broad range of exploration and data-collection needs. The main contribution is the extensible architecture for modularized airborne sensor deployment and real-time data visualisation. Our open-source Android application provides data collection, flight path definition and map tools. Total cost of the system is below 800 dollars. The flexibility of the system is illustrated by mapping the location of Bluetooth beacons (iBeacons) on a ground field and by measuring water temperature in a lake. PMID:28098819
Low-Cost Oil Quality Sensor Based on Changes in Complex Permittivity
Pérez, Angel Torres; Hadfield, Mark
2011-01-01
Real time oil quality monitoring techniques help to protect important industry assets, minimize downtime and reduce maintenance costs. The measurement of a lubricant’s complex permittivity is an effective indicator of the oil degradation process and it can be useful in condition based maintenance (CBM) to select the most adequate oil replacement maintenance schedules. A discussion of the working principles of an oil quality sensor based on a marginal oscillator to monitor the losses of the dielectric at high frequencies (>1 MHz) is presented. An electronic design procedure is covered which results in a low cost, effective and ruggedized sensor implementation suitable for use in harsh environments. PMID:22346666
Low Cost and Flexible UAV Deployment of Sensors.
Sørensen, Lars Yndal; Jacobsen, Lars Toft; Hansen, John Paulin
2017-01-14
This paper presents a platform for airborne sensor applications using low-cost, open-source components carried by an easy-to-fly unmanned aircraft vehicle (UAV). The system, available in open-source , is designed for researchers, students and makers for a broad range of exploration and data-collection needs. The main contribution is the extensible architecture for modularized airborne sensor deployment and real-time data visualisation. Our open-source Android application provides data collection, flight path definition and map tools. Total cost of the system is below 800 dollars. The flexibility of the system is illustrated by mapping the location of Bluetooth beacons (iBeacons) on a ground field and by measuring water temperature in a lake.
A low-cost, ultra-fast and ultra-low noise preamplifier for silicon avalanche photodiodes
NASA Astrophysics Data System (ADS)
Gasmi, Khaled
2018-02-01
An ultra-fast and ultra-low noise preamplifier for amplifying the fast and weak electrical signals generated by silicon avalanche photodiodes has been designed and developed. It is characterized by its simplicity, compactness, reliability and low cost of construction. A very wide bandwidth of 300 MHz, a very good linearity from 1 kHz to 280 MHz, an ultra-low noise level at the input of only 1.7 nV Hz-1/2 and a very good stability are its key features. The compact size (70 mm × 90 mm) and light weight (45 g), as well as its excellent characteristics, make this preamplifier very competitive compared to any commercial preamplifier. The preamplifier, which is a main part of the detection system of a homemade laser remote sensing system, has been successfully tested. In addition, it is versatile and can be used in any optical detection system requiring high speed and very low noise electronics.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-01-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints. PMID:27417734
Resistive flex sensors: a survey
NASA Astrophysics Data System (ADS)
Saggio, Giovanni; Riillo, Francesco; Sbernini, Laura; Quitadamo, Lucia Rita
2016-01-01
Resistive flex sensors can be used to measure bending or flexing with relatively little effort and a relatively low budget. Their lightness, compactness, robustness, measurement effectiveness and low power consumption make these sensors useful for manifold applications in diverse fields. Here, we provide a comprehensive survey of resistive flex sensors, taking into account their working principles, manufacturing aspects, electrical characteristics and equivalent models, useful front-end conditioning circuitry, and physic-bio-chemical aspects. Particular effort is devoted to reporting on and analyzing several applications of resistive flex sensors, related to the measurement of body position and motion, and to the implementation of artificial devices. In relation to the human body, we consider the utilization of resistive flex sensors for the measurement of physical activity and for the development of interaction/interface devices driven by human gestures. Concerning artificial devices, we deal with applications related to the automotive field, robots, orthosis and prosthesis, musical instruments and measuring tools. The presented literature is collected from different sources, including bibliographic databases, company press releases, patents, master’s theses and PhD theses.
YSAR: a compact low-cost synthetic aperture radar
NASA Astrophysics Data System (ADS)
Thompson, Douglas G.; Arnold, David V.; Long, David G.; Miner, Gayle F.; Karlinsey, Thomas W.; Robertson, Adam E.
1997-09-01
The Brigham Young University Synthetic Aperture Radar (YSAR) is a compact, inexpensive SAR system which can be flown on a small aircraft. The system has exhibited a resolution of approximately 0.8 m by 0.8 m in test flights in calm conditions. YSAR has been used to collect data over archeological sites in Israel. Using a relatively low frequency (2.1 GHz), we hope to be able to identify walls or other archeological features to assist in excavation. A large data set of radar and photographic data have been collected over sites at Tel Safi, Qumran, Tel Micnah, and the Zippori National Forest in Israel. We show sample images from the archeological data. We are currently working on improved autofocus algorithms for this data and are developing a small, low-cost interferometric SAR system (YINSAR) for operation from a small aircraft.
Towards low cost photoacoustic Microscopy system for evaluation of skin health
NASA Astrophysics Data System (ADS)
Hariri, Ali; Fatima, Afreen; Mohammadian, Nafiseh; Bely, Nicholas; Nasiriavanaki, Mohammadreza
2016-09-01
Photoacoustic imaging (PAI) involves both optical and ultrasound imaging, owing to this combination the system is capable of generating high resolution images with good penetration depth. With the growing applications of PAI in neurology, vascular biology, dermatology, ophthalmology, tissue engineering, angiogenesis etc., there is a need to make the system more compact, cheap and effective. Therefore we designed an economical and compact version of PAI systems by replacing expensive and sophisticated lasers with a robust pulsed laser diode of 905 nm wavelength. In this study, we determine the feasibility of the Photoacoustic imaging with a very low excitation energy of 0.1uJ in Photoacoustic microscopy. We developed a low cost portable Photoacoustic Imaging including microscopy (both reflection) Phantom study was performed in this configuration and also ex-vivo image was obtained from mouse skin.
NASA Astrophysics Data System (ADS)
Thoreson, E. J.; Stievater, T. H.; Rabinovich, W. S.; Ferraro, M. S.; Papanicolaou, N. A.; Bass, R.; Boos, J. B.; Stepnowski, J. L.; McGill, R. A.
2008-10-01
Low cost passive detection of Chemical Warfare Agents (CWA) and being able to distinguish them from interferents is of great interest in the protection of human capital. If CWA sensors could be made cheaply enough, they could be deployed profusely throughout the environment intended for protection. NRL (Naval Research Labs) has demonstrated a small sensor with potentially very low unit cost and compatible with high volume production which has the ability to distinguish between H2O, DMMP, and Toluene. Additionally, they have measured concentrations as low as 17 ppb passively in a package the size of a quarter. Using the latest MEMS technology coupled with advanced chemical identification algorithms we propose a development path for a low cost, highly integrated chemical sensor capable of detecting CWA's, Explosives, VOC's (Volatile Organic Chemicals), and TIC's (Toxic Industrial Chemicals). ITT AES (Advanced Engineering & Sciences) has partnered with NRL (Naval Research Labs) to develop this ``microharp'' technology into a field deployable sensor that will be capable of remote communication with a central server.
A multi-channel tunable source for atomic sensors
NASA Astrophysics Data System (ADS)
Bigelow, Matthew S.; Roberts, Tony D.; McNeil, Shirley A.; Hawthorne, Todd; Battle, Phil
2015-09-01
We have designed and completed initial testing on a laser source suitable for atomic interferometry from compact, robust, integrated components. Our design is enabled by capitalizing on robust, well-commercialized, low-noise telecom components with high reliability and declining costs which will help to drive the widespread deployment of this system. The key innovation is the combination of current telecom-based fiber laser and modulator technology with periodicallypoled waveguide technology to produce tunable laser light at rubidium D1 and D2 wavelengths (and expandable to other alkalis) using second harmonic generation (SHG). Unlike direct-diode sources, this source is immune to feedback at the Rb line eliminating the need for bulky high-power isolators in the system. In addition, the source has GHz-level frequency agility and in our experiments was found to only be limited by the agility of our RF generator. As a proof-of principle, the source was scanned through the Doppler-broadened Rb D2 absorption line. With this technology, multiple channels can be independently tuned to produce the fields needed for addressing atomic states in atom interferometers and clocks. Thus, this technology could be useful in the development cold-atom inertial sensors and gyroscopes.
NASA Astrophysics Data System (ADS)
Mignani, Anna G.; Ciaccheri, Leonardo; Mencaglia, Andrea A.; Tuccio, Lorenza; Agati, Giovanni
2015-05-01
Nondestructive in situ determination of the antioxidant lycopene of fresh tomato fruits is of large interest for the growers, willing to optimize the harvest time for high quality products. For this, we developed a portable LED-based colorimeter which was able to measure reflectance spectra of whole tomatoes in the 400-750 nm range. The tomato skins from the same samples were then frozen in liquid nitrogen, extracted with an acetone/ethanol/hexane mixture and analyzed by means of a spectrophotometer for their lycopene content. Concentration of lycopene was varying between 70 and 550 mg/Kg fresh weight skin. Partial Least Square regression was used to correlate spectral data to the tomato lycopene content. The multivariate processing of the reflectance data showed that lycopene content could be nicely predicted with a coefficient of determination R2=0.945 and a root mean square error of cross-validation RMSECV=57 mg/Kg skin fresh weight. These results suggest that portable, low-cost and compact LED-based sensors appear to be promising instruments for the nondestructive assessment of tomato lycopene even in the field.
Simulation, fabrication and characterization of THz metamaterial absorbers.
Grant, James P; McCrindle, Iain J H; Cumming, David R S
2012-12-27
Metamaterials (MM), artificial materials engineered to have properties that may not be found in nature, have been widely explored since the first theoretical(1) and experimental demonstration(2) of their unique properties. MMs can provide a highly controllable electromagnetic response, and to date have been demonstrated in every technologically relevant spectral range including the optical(3), near IR(4), mid IR(5) , THz(6) , mm-wave(7) , microwave(8) and radio(9) bands. Applications include perfect lenses(10), sensors(11), telecommunications(12), invisibility cloaks(13) and filters(14,15). We have recently developed single band(16), dual band(17) and broadband(18) THz metamaterial absorber devices capable of greater than 80% absorption at the resonance peak. The concept of a MM absorber is especially important at THz frequencies where it is difficult to find strong frequency selective THz absorbers(19). In our MM absorber the THz radiation is absorbed in a thickness of ~ λ/20, overcoming the thickness limitation of traditional quarter wavelength absorbers. MM absorbers naturally lend themselves to THz detection applications, such as thermal sensors, and if integrated with suitable THz sources (e.g. QCLs), could lead to compact, highly sensitive, low cost, real time THz imaging systems.
ISFET Based Microsensors for Environmental Monitoring
Jimenez-Jorquera, Cecilia; Orozco, Jahir; Baldi, Antoni
2010-01-01
The use of microsensors for in-field monitoring of environmental parameters is gaining interest due to their advantages over conventional sensors. Among them microsensors based on semiconductor technology offer additional advantages such as small size, robustness, low output impedance and rapid response. Besides, the technology used allows integration of circuitry and multiple sensors in the same substrate and accordingly they can be implemented in compact probes for particular applications e.g., in situ monitoring and/or on-line measurements. In the field of microsensors for environmental applications, Ion Selective Field Effect Transistors (ISFETs) have a special interest. They are particularly helpful for measuring pH and other ions in small volumes and they can be integrated in compact flow cells for continuous measurements. In this paper the technologies used to fabricate ISFETs and a review of the role of ISFETs in the environmental field are presented. PMID:22315527
Intelligent Memory Module Overcomes Harsh Environments
NASA Technical Reports Server (NTRS)
2008-01-01
Solar cells, integrated circuits, and sensors are essential to manned and unmanned space flight and exploration, but such systems are highly susceptible to damage from radiation. Especially problematic, the Van Allen radiation belts encircle Earth in concentric radioactive tori at distances from about 6,300 to 38,000 km, though the inner radiation belt can dip as low as 700 km, posing a severe hazard to craft and humans leaving Earth s atmosphere. To avoid this radiation, the International Space Station and space shuttles orbit at altitudes between 275 and 460 km, below the belts range, and Apollo astronauts skirted the edge of the belts to minimize exposure, passing swiftly through thinner sections of the belts and thereby avoiding significant side effects. This radiation can, however, prove detrimental to improperly protected electronics on satellites that spend the majority of their service life in the harsh environment of the belts. Compact, high-performance electronics that can withstand extreme environmental and radiation stress are thus critical to future space missions. Increasing miniaturization of electronics addresses the need for lighter weight in launch payloads, as launch costs put weight at a premium. Likewise, improved memory technologies have reduced size, cost, mass, power demand, and system complexity, and improved high-bandwidth communication to meet the data volume needs of the next-generation high-resolution sensors. This very miniaturization, however, has exacerbated system susceptibility to radiation, as the charge of ions may meet or exceed that of circuitry, overwhelming the circuit and disrupting operation of a satellite. The Hubble Space Telescope, for example, must turn off its sensors when passing through intense radiation to maintain reliable operation. To address the need for improved data quality, additional capacity for raw and processed data, ever-increasing resolution, and radiation tolerance, NASA spurred the development of the Radiation Tolerant Intelligent Memory Stack (RTIMS).
Prototype of a low cost multiparameter probe
NASA Astrophysics Data System (ADS)
Koski, K.; Schwingle, R.; Pullin, M.
2010-12-01
Commercial multi-parameter probes provide accurate, high-resolution temporal data collection of a variety of water quality parameters, but their cost (>5,000) prohibits more than a few sampling locations. We present a design and prototype for a low cost (<250) probe. The cost of the probe is ~5% of commercially available probes, allowing for data collection from ~20 times more sampling points in a field location. The probe is constructed from a single-board microcontroller, a commercially available temperature sensor, a conductivity sensor, and a fabricated optical rhodamine sensor. Using a secure digital (SD) memory card, the probe can record over a month of data at a user specified interval. Construction, calibration, field deployment and data retrieval can be accomplished by a skilled undergraduate. Initial deployment will take place as part of a tracer test in the Valles Caldera National Preserve in northern New Mexico. Future work includes: addition of commercial ion selective electrodes (pH, bromide, nitrate, and others); construction of optically based sensors (chlorophyll, dissolved oxygen, and others); wireless networking between the sensors; and reduction of biofouling.
Khan, Niazul Islam; Maddaus, Alec G; Song, Edward
2018-01-15
Recently, inkjet-printing has gained increased popularity in applications such as flexible electronics and disposable sensors, as well as in wearable sensors because of its multifarious advantages. This work presents a novel, low-cost immobilization technique using inkjet-printing for the development of an aptamer-based biosensor for the detection of lysozyme, an important biomarker in various disease diagnosis. The strong affinity between the carbon nanotube (CNT) and the single-stranded DNA is exploited to immobilize the aptamers onto the working electrode by printing the ink containing the dispersion of CNT-aptamer complex. The inkjet-printing method enables aptamer density control, as well as high resolution patternability. Our developed sensor shows a detection limit of 90 ng/mL with high target selectivity against other proteins. The sensor also demonstrates a shelf-life for a reasonable period. This technology has potential for applications in developing low-cost point-of-care diagnostic testing kits for home healthcare.
Sensor emplacement testing at Poker Flat, Alaska
NASA Astrophysics Data System (ADS)
Reusch, A.; Beaudoin, B. C.; Anderson, K. E.; Azevedo, S.; Carothers, L.; Love, M.; Miller, P. E.; Parker, T.; Pfeifer, M.; Slad, G.; Thomas, D.; Aderhold, K.
2013-12-01
PASSCAL provides equipment and support for temporary seismic projects. Speed and efficiency of deployments are essential. A revised emplacement technique of putting broadband sensors directly into soil (aka direct burial) is being tested. The first phase (fall 2011 to spring 2013) comparing data quality and sensor stability between the direct burial and the traditional 1 m deep temporary PASSCAL-style vault in a wet and noisy site near San Antonio, NM is complete. Results suggest there is little or no difference in sensor performance in the relatively high-noise environment of this initial test. The second phase was started in November 2012 with the goal of making the same comparison, but at Poker Flat, Alaska, in a low-noise, high-signal, cold and wet environment, alongside a Transportable Array (TA) deployment to be used as a performance control. This location is in an accessible and secure area with very low site noise. In addition to benefiting future worldwide PASSCAL deployments, the Poker Flat experiment serves a secondary purpose of testing modifications necessary to successfully deploy and recover broadband stations in a cold environment with the limited logistics anticipated for remote Flexible Array (FA) and PASSCAL Program deployments in Alaska. Developing emplacement techniques that maintain high data quality and data return while minimizing logistics is critical to enable principle investigators to effectively and efficiently co-locate within the future TA Alaska footprint. Three Nanometrics sensors were installed in November 2012 in power-augered holes 76 cm in depth: a Trillium Compact Posthole (PH) and two Trillium 120PH units (one standard PH and one enhanced PHQ). The installations took less than 8 hours in -30°C conditions with 4 hours of usable daylight. The Compact PH and the 120PHQ are delivering data in realtime, while the 120PH is testing standalone power and data collection systems. Preliminary results compare favorably to each other as well as the nearby Trillium 240 in a traditional TA surface vault and a 120PH in a 5 m machine-drilled borehole. This summer, two Trillium 120PA sensors were installed at a depth of 54 cm in traditional PASSCAL-style vaults, adjacent to the Trillium Compact PH, Trillium 120PH and 120PHQ emplacements. Analysis of the data collected from these five sensors will include the use of probability density functions of power spectral density to examine temporal trends in noise, signal-to-noise ratios for local, regional, and teleseismic earthquakes, and coherence of both noise and earthquake signal recordings to compare the data quality of direct burial versus temporary PASSCAL-style vaults sensor emplacements.
Using Low Cost Environmental Sensors in Geoscience Education
NASA Astrophysics Data System (ADS)
Leeman, J.; Ammon, C. J.; Anandakrishnan, S.
2014-12-01
Advances in process technology have drastically reduced the cost of manufacturing almost every type of sensor and micro-controller, putting low-to-mid grade sensor technology in the reach of educators and hobbyists. We demonstrate how a low cost magnetometer and an Arduino micro-controller can be used in education. Students can easily connect the sensor to the Arduino and collect three-component magnetic field data. Experiments can easily be turned into long-term monitoring projects by connecting sensors to the internet and providing an Internet-of-Things interface to store and to display the data in near-real time. Low-cost sensors are generally much noisier than their research grade counterparts, but can still provide an opportunity for students to learn about fundamental concepts such as signal quality, sampling, averaging, and filtering and to gain hands-on, concrete experience with observations. Sensors can be placed at different locations and compared both qualitatively and quantitatively. For example, with an inexpensive magnetometer, students can examine diurnal magnetic field variations and look for magnetic storms. Magnetic field orientation can be calculated and compared to the predicted geomagnetic field orientation at a given location. Data can be stored in simple text files to facilitate analysis with any convenient package. We illustrate the idea using Python notebooks, allowing students to explore the data interactively and to learn the basic principles of programming and reproducible research. Using an Arduino encourages students to interact with open-source data collection hardware and to experiment with ways to quickly, cheaply, and effectively measure the environment. Analysis of these data can lead to a deeper understanding of both geoscience and data processing.
Ultra-compact MEMS FTIR spectrometer
NASA Astrophysics Data System (ADS)
Sabry, Yasser M.; Hassan, Khaled; Anwar, Momen; Alharon, Mohamed H.; Medhat, Mostafa; Adib, George A.; Dumont, Rich; Saadany, Bassam; Khalil, Diaa
2017-05-01
Portable and handheld spectrometers are being developed and commercialized in the late few years leveraging the rapidly-progressing technology and triggering new markets in the field of on-site spectroscopic analysis. Although handheld devices were commercialized for the near-infrared spectroscopy (NIRS), their size and cost stand as an obstacle against the deployment of the spectrometer as spectral sensing components needed for the smart phone industry and the IoT applications. In this work we report a chip-sized microelectromechanical system (MEMS)-based FTIR spectrometer. The core optical engine of the solution is built using a passive-alignment integration technique for a selfaligned MEMS chip; self-aligned microoptics and a single detector in a tiny package sized about 1 cm3. The MEMS chip is a monolithic, high-throughput scanning Michelson interferometer fabricated using deep reactive ion etching technology of silicon-on-insulator substrate. The micro-optical part is used for conditioning the input/output light to/from the MEMS and for further light direction to the detector. Thanks to the all-reflective design of the conditioning microoptics, the performance is free of chromatic aberration. Complemented by the excellent transmission properties of the silicon in the infrared region, the integrated solution allows very wide spectral range of operation. The reported sensor's spectral resolution is about 33 cm-1 and working in the range of 1270 nm to 2700 nm; upper limited by the extended InGaAs detector. The presented solution provides a low cost, low power, tiny size, wide wavelength range NIR spectral sensor that can be manufactured with extremely high volumes. All these features promise the compatibility of this technology with the forthcoming demand of smart portable and IoT devices.
IEEE-802.15.4-based low-power body sensor node with RF energy harvester.
Tran, Thang Viet; Chung, Wan-Young
2014-01-01
This paper proposes the design and implementation of a low-voltage and low-power body sensor node based on the IEEE 802.15.4 standard to collect electrocardiography (ECG) and photoplethysmography (PPG) signals. To achieve compact size, low supply voltage, and low power consumption, the proposed platform is integrated into a ZigBee mote, which contains a DC-DC booster, a PPG sensor interface module, and an ECG front-end circuit that has ultra-low current consumption. The input voltage of the proposed node is very low and has a wide range, from 0.65 V to 3.3 V. An RF energy harvester is also designed to charge the battery during the working mode or standby mode of the node. The power consumption of the proposed node reaches 14 mW in working mode to prolong the battery lifetime. The software is supported by the nesC language under the TinyOS environment, which enables the proposed node to be easily configured to function as an individual health monitoring node or a node in a wireless body sensor network (BSN). The proposed node is used to set up a wireless BSN that can simultaneously collect ECG and PPG signals and monitor the results on the personal computer.
NASA Astrophysics Data System (ADS)
Lee, El-Hang; Lee, S. G.; O, B. H.; Park, S. G.; Noh, H. S.; Kim, K. H.; Song, S. H.
2006-09-01
A collective overview and review is presented on the original work conducted on the theory, design, fabrication, and in-tegration of micro/nano-scale optical wires and photonic devices for applications in a newly-conceived photonic systems called "optical printed circuit board" (O-PCBs) and "VLSI photonic integrated circuits" (VLSI-PIC). These are aimed for compact, high-speed, multi-functional, intelligent, light-weight, low-energy and environmentally friendly, low-cost, and high-volume applications to complement or surpass the capabilities of electrical PCBs (E-PCBs) and/or VLSI electronic integrated circuit (VLSI-IC) systems. These consist of 2-dimensional or 3-dimensional planar arrays of micro/nano-optical wires and circuits to perform the functions of all-optical sensing, storing, transporting, processing, switching, routing and distributing optical signals on flat modular boards or substrates. The integrated optical devices include micro/nano-scale waveguides, lasers, detectors, switches, sensors, directional couplers, multi-mode interference devices, ring-resonators, photonic crystal devices, plasmonic devices, and quantum devices, made of polymer, silicon and other semiconductor materials. For VLSI photonic integration, photonic crystals and plasmonic structures have been used. Scientific and technological issues concerning the processes of miniaturization, interconnection and integration of these systems as applicable to board-to-board, chip-to-chip, and intra-chip integration, are discussed along with applications for future computers, telecommunications, and sensor-systems. Visions and challenges toward these goals are also discussed.
Hard and flexible optical printed circuit board
NASA Astrophysics Data System (ADS)
Lee, El-Hang; Lee, Hyun Sik; Lee, S. G.; O, B. H.; Park, S. G.; Kim, K. H.
2007-02-01
We report on the design and fabrication of hard and flexible optical printed circuit boards (O-PCBs). The objective is to realize generic and application-specific O-PCBs, either in hard form or flexible form, that are compact, light-weight, low-energy, high-speed, intelligent, and environmentally friendly, for low-cost and high-volume universal applications. The O-PCBs consist of 2-dimensional planar arrays of micro/nano-scale optical wires, circuits and devices that are interconnected and integrated to perform the functions of sensing, storing, transporting, processing, switching, routing and distributing optical signals on flat modular boards. For fabrication, the polymer and organic optical wires and waveguides are first fabricated on a board and are used to interconnect and integrate micro/nano-scale photonic devices. The micro/nano-optical functional devices include lasers, detectors, switches, sensors, directional couplers, multi-mode interference devices, ring-resonators, photonic crystal devices, plasmonic devices, and quantum devices. For flexible boards, the optical waveguide arrays are fabricated on flexible poly-ethylen terephthalate (PET) substrates by UV embossing. Electrical layer carrying VCSEL and PD array is laminated with the optical layer carrying waveguide arrays. Both hard and flexible electrical lines are replaced with high speed optical interconnection between chips over four waveguide channels up to 10Gbps on each. We discuss uses of hard or flexible O-PCBs for telecommunication systems, computer systems, transportation systems, space/avionic systems, and bio-sensor systems.
Low-Cost Linear Optical Sensors.
ERIC Educational Resources Information Center
Kinsey, Kenneth F.; Meisel, David D.
1994-01-01
Discusses the properties and application of three light-to-voltage optical sensors. The sensors have been used for sensing diffraction patterns, the inverse-square law, and as a fringe counter with an interferometer. (MVL)
Fiber optic medical pressure-sensing system employing intelligent self-calibration
NASA Astrophysics Data System (ADS)
He, Gang
1996-01-01
In this article, we describe a fiber-optic catheter-type pressure-sensing system that has been successfully introduced for medical diagnostic applications. We present overall sensors and optoelectronics designs, and highlight product development efforts that lead to a reliable and accurate disposable pressure-sensing system. In particular, the incorporation of an intelligent on-site self-calibration approach allows limited sensor reuses for reducing end-user costs and for system adaptation to wide sensor variabilities associated with low-cost manufacturing processes. We demonstrate that fiber-optic sensors can be cost-effectively produced to satisfy needs of certain medical market segments.
Carbon Nanotube Sensors for Gas and Vapor Detection in Space and Terrestrial Applications
NASA Technical Reports Server (NTRS)
Li, Jing
2005-01-01
Viewgraphs detailing the development of a nanostructure engineered, portable, low cost, low power consumption, room temperature operated chemical sensor for space and terrestrial applications is presented. The topics include: 1) Applications and Requirements; 2) Nanotechnology Advantages; 3) Current Studies on NanoChemical Sensors; and 4) Our Research Status and Results.
Handheld probe for portable high frame photoacoustic/ultrasound imaging system
NASA Astrophysics Data System (ADS)
Daoudi, K.; van den Berg, P. J.; Rabot, O.; Kohl, A.; Tisserand, S.; Brands, P.; Steenbergen, W.
2013-03-01
Photoacoustics is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophors. In current research, this technique uses large and costly photoacoustic systems with a low frame rate imaging. To open the door for widespread clinical use, a compact, cost effective and fast system is required. In this paper we report on the development of a small compact handset pulsed laser probe which will be connected to a portable ultrasound system for real-time photoacoustic imaging and ultrasound imaging. The probe integrates diode lasers driven by an electrical driver developed for very short high power pulses. It uses specifically developed highly efficient diode stacks with high frequency repetition rate up to 10 kHz, emitting at 800nm wavelength. The emitted beam is collimated and shaped with compact micro optics beam shaping system delivering a homogenized rectangular laser beam intensity distribution. The laser block is integrated with an ultrasound transducer in an ergonomically designed handset probe. This handset is a building block enabling for a low cost high frame rate photoacoustic and ultrasound imaging system. The probe was used with a modified ultrasound scanner and was tested by imaging a tissue mimicking phantom.
MiniDSS: a low-power and high-precision miniaturized digital sun sensor
NASA Astrophysics Data System (ADS)
de Boer, B. M.; Durkut, M.; Laan, E.; Hakkesteegt, H.; Theuwissen, A.; Xie, N.; Leijtens, J. L.; Urquijo, E.; Bruins, P.
2017-11-01
A high-precision and low-power miniaturized digital sun sensor has been developed at TNO. The single-chip sun sensor comprises an application specific integrated circuit (ASIC) on which an active pixel sensor (APS), read-out and processing circuitry as well as communication circuitry are combined. The design was optimized for low recurrent cost. The sensor is albedo insensitive and the prototype combines an accuracy in the order of 0.03° with a mass of just 72 g and a power consumption of only 65 mW.
High dynamic range pixel architecture for advanced diagnostic medical x-ray imaging applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izadi, Mohammad Hadi; Karim, Karim S.
2006-05-15
The most widely used architecture in large-area amorphous silicon (a-Si) flat panel imagers is a passive pixel sensor (PPS), which consists of a detector and a readout switch. While the PPS has the advantage of being compact and amenable toward high-resolution imaging, small PPS output signals are swamped by external column charge amplifier and data line thermal noise, which reduce the minimum readable sensor input signal. In contrast to PPS circuits, on-pixel amplifiers in a-Si technology reduce readout noise to levels that can meet even the stringent requirements for low noise digital x-ray fluoroscopy (<1000 noise electrons). However, larger voltagesmore » at the pixel input cause the output of the amplified pixel to become nonlinear thus reducing the dynamic range. We reported a hybrid amplified pixel architecture based on a combination of PPS and amplified pixel designs that, in addition to low noise performance, also resulted in large-signal linearity and consequently higher dynamic range [K. S. Karim et al., Proc. SPIE 5368, 657 (2004)]. The additional benefit in large-signal linearity, however, came at the cost of an additional pixel transistor. We present an amplified pixel design that achieves the goals of low noise performance and large-signal linearity without the need for an additional pixel transistor. Theoretical calculations and simulation results for noise indicate the applicability of the amplified a-Si pixel architecture for high dynamic range, medical x-ray imaging applications that require switching between low exposure, real-time fluoroscopy and high-exposure radiography.« less
Low cost attitude control system scanwheel development
NASA Astrophysics Data System (ADS)
Bialke, William; Selby, Vaughn
1991-03-01
In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of low cost scanning horizon sensor coupled to a low cost/low power consumption Reaction Wheel Assembly was initiated. This report addresses the details of the versatile design resulting from this effort. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.
Low cost attitude control system scanwheel development
NASA Technical Reports Server (NTRS)
Bialke, William; Selby, Vaughn
1991-01-01
In order to satisfy a growing demand for low cost attitude control systems for small spacecraft, development of low cost scanning horizon sensor coupled to a low cost/low power consumption Reaction Wheel Assembly was initiated. This report addresses the details of the versatile design resulting from this effort. Tradeoff analyses for each of the major components are included, as well as test data from an engineering prototype of the hardware.
Zeolite-based Impedimetric Gas Sensor Device in Low-cost Technology for Hydrocarbon Gas Detection
Reiß, Sebastian; Hagen, Gunter; Moos, Ralf
2008-01-01
Due to increasing environmental concerns the need for inexpensive selective gas sensors is increasing. This work deals with transferring a novel zeolite-based impedimetric hydrocarbon gas sensor principle, which has been originally manufactured in a costly combination of photolithography, thin-film processes, and thick-film processes to a low-cost technology comprising only thick-film processes and one electroplating step. The sensing effect is based on a thin chromium oxide layer between the interdigital electrodes and a Pt-loaded ZSM-5 zeolite film. When hydrocarbons are present in the sensor ambient, the electrical sensor impedance increases strongly and selectively. In the present work, the chromium oxide film is electroplated on Au screen-printed interdigital electrodes and then oxidized to Cr2O3. The electrode area is covered with the screen-printed zeolite. The sensor device is self-heated utilizing a planar platinum heater on the backside. The best sensor performance is obtained at a frequency of 3 Hz at around 350 °C. The good selectivity of the original sensor setup could be confirmed, but a strong cross-sensitivity to ammonia occurs, which might prohibit its original intention for use in automotive exhausts. PMID:27873966
Optical Fiber Thermometer Based on Fiber Bragg Gratings
NASA Astrophysics Data System (ADS)
Rosli, Ekbal Bin; Mohd. Noor, Uzer
2018-03-01
Fiber Bragg grating has generated much interest in use as sensors to measure strain, temperature, and other physical parameters. It also the most common component used to develop this sensor with the advantages of simple, intrinsic sensing elements, electrically passive operation, EMI immunity, high sensitivity, compact size and potentially low cost [6]. This paper reports the design of an optical fiber thermometer based on fiber Bragg gratings. The system was developed for detecting temperature and strain by monitoring the shift of Bragg wavelength. The shifting of Bragg wavelength is used to indicate the temperature and strain due to the change in the surrounding temperature and strain. When the temperature and strain reach the exact wavelength level of the system, the temperature and strain value will display on the Arduino liquid crystal display (LCD). The optical fiber will provide the broadband light source and after passing the FBG the Bragg wavelength into the optical spectrum analyzer (OSA). The system is based on FBG as a physical quantity sensor. The temperatures measured is taken from the water bath and that of the strain is provided by amount of slotted mass used. The outcome of this project is to characterize the Bragg wavelength shifting from the fiber Bragg grating output. As the conclusion, this project provides an efficient optical fiber thermometer in measuring temperature and strain in order to replace the use of conventional electrical instruments.
Low SWaP multispectral sensors using dichroic filter arrays
NASA Astrophysics Data System (ADS)
Dougherty, John; Varghese, Ron
2015-06-01
The benefits of multispectral imaging are well established in a variety of applications including remote sensing, authentication, satellite and aerial surveillance, machine vision, biomedical, and other scientific and industrial uses. However, many of the potential solutions require more compact, robust, and cost-effective cameras to realize these benefits. The next generation of multispectral sensors and cameras needs to deliver improvements in size, weight, power, portability, and spectral band customization to support widespread deployment for a variety of purpose-built aerial, unmanned, and scientific applications. A novel implementation uses micro-patterning of dichroic filters1 into Bayer and custom mosaics, enabling true real-time multispectral imaging with simultaneous multi-band image acquisition. Consistent with color image processing, individual spectral channels are de-mosaiced with each channel providing an image of the field of view. This approach can be implemented across a variety of wavelength ranges and on a variety of detector types including linear, area, silicon, and InGaAs. This dichroic filter array approach can also reduce payloads and increase range for unmanned systems, with the capability to support both handheld and autonomous systems. Recent examples and results of 4 band RGB + NIR dichroic filter arrays in multispectral cameras are discussed. Benefits and tradeoffs of multispectral sensors using dichroic filter arrays are compared with alternative approaches - including their passivity, spectral range, customization options, and scalable production.
Field-portable lensfree tomographic microscope†
Isikman, Serhan O.; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan
2011-01-01
We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (~20 mm3) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ~110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ~50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311
A Rapid Process for Fabricating Gas Sensors
Hsiao, Chun-Ching; Luo, Li-Siang
2014-01-01
Zinc oxide (ZnO) is a low-toxicity and environmentally-friendly material applied on devices, sensors or actuators for “green” usage. A porous ZnO film deposited by a rapid process of aerosol deposition (AD) was employed as the gas-sensitive material in a CO gas sensor to reduce both manufacturing cost and time, and to further extend the AD application for a large-scale production. The relative resistance change (ΔR/R) of the ZnO gas sensor was used for gas measurement. The fabricated ZnO gas sensors were measured with operating temperatures ranging from 110 °C to 180 °C, and CO concentrations ranging from 100 ppm to 1000 ppm. The sensitivity and the response time presented good performance at increasing operating temperatures and CO concentrations. AD was successfully for applied for making ZnO gas sensors with great potential for achieving high deposition rates at low deposition temperatures, large-scale production and low cost. PMID:25010696
NASA Astrophysics Data System (ADS)
Chetty, S.; Field, L. A.
2013-12-01
The Arctic ocean's continuing decrease of summer-time ice is related to rapidly diminishing multi-year ice due to the effects of climate change. Ice911 Research aims to develop environmentally respectful materials that when deployed will increase the albedo, enhancing the formation and/preservation of multi-year ice. Small scale deployments using various materials have been done in Canada, California's Sierra Nevada Mountains and a pond in Minnesota to test the albedo performance and environmental characteristics of these materials. SWIMS is a sophisticated autonomous sensor system being developed to measure the albedo, weather, water temperature and other environmental parameters. The system (SWIMS) employs low cost, high accuracy/precision sensors, high resolution cameras, and an extreme environment command and data handling computer system using satellite and terrestrial wireless communication. The entire system is solar powered with redundant battery backup on a floating buoy platform engineered for low temperature (-40C) and high wind conditions. The system also incorporates tilt sensors, sonar based ice thickness sensors and a weather station. To keep the costs low, each SWIMS unit measures incoming and reflected radiation from the four quadrants around the buoy. This allows data from four sets of sensors, cameras, weather station, water temperature probe to be collected and transmitted by a single on-board solar powered computer. This presentation covers the technical, logistical and cost challenges in designing, developing and deploying these stations in remote, extreme environments. Image captured by camera #3 of setting sun on the SWIMS station One of the images captured by SWIMS Camera #4
Hollow fibers for compact infrared gas sensors
NASA Astrophysics Data System (ADS)
Lambrecht, A.; Hartwig, S.; Herbst, J.; Wöllenstein, J.
2008-02-01
Hollow fibers can be used for compact infrared gas sensors. The guided light is absorbed by the gas introduced into the hollow core. High sensitivity and a very small sampling volume can be achieved depending on fiber parameters i.e. attenuation, flexibility, and gas exchange rates. Different types of infrared hollow fibers including photonic bandgap fibers were characterized using quantum cascade lasers and thermal radiation sources. Obtained data are compared with available product specifications. Measurements with a compact fiber based ethanol sensor are compared with a system simulation. First results on the detection of trace amounts of the explosive material TATP using hollow fibers and QCL will be shown.
NASA Astrophysics Data System (ADS)
Collier, A. M.; Hannigan, M.; Piedrahita, R.; Casey, J. G.; Johnston, J.; Chiang, S.
2016-12-01
The growing accessibility of low-cost air quality monitoring technologies has led to their increased usage among community-based organizations, particularly for the monitoring of pollutants dangerous to human health (e.g., hazardous air pollutants or HAPS). However, often these low-cost sensors are `off-the-shelf' and are being utilized in a manner that differs from their intended purpose - necessitating high quality calibrations. For example, VOC sensors intended for the detection of high levels of a particular compound in an industrial setting may instead be used for ambient monitoring of a group of VOCs. Academic/community partnerships can be an ideal way to improve this type of sensor quantification while providing a community with not only the opportunity to use these technologies with additional support around data quality, but also the opportunity for education around the abilities and applications of low-cost sensors. In the spring of 2016, our lab at the University of Colorado, Boulder partnered with communities in Los Angeles and Kern County to deploy low-cost air quality monitors for the purpose of quantifying methane and non-methane hydrocarbon signals in an effort to learn more about potential impacts from local sources (e.g., nearby highways and oil & gas development). The monitoring platform was developed in our lab and is capable of logging multiple gas phase species as well as some environmental parameters. The monitors include two different metal oxide VOC sensors - each with slightly different sensing capabilities. Calibration was achieved using a pre- and post-deployment field normalization to reference monitoring equipment maintained by the South Coast Air Quality Management District. Monitors were then deployed at locations throughout the community. We will present results on our efforts to quantify a total non-methane hydrocarbon signal, observations from the field data, and recommendations for academic/community partnerships formed around air quality monitoring.
Measuring PM and related air pollutants using low-cost ...
Emerging air quality sensors may play a key role in better characterizing levels of air pollution in a variety of settings There are a wide range of low-cost (< $500 US) sensors on the market, but few have been characterized. If accurate, this new generation of inexpensive sensors can potentially allow larger fleets of monitors to be deployed to better study the spatial and temporal variability of pollutants. The small size and light weight of these sensors also allows for the possibility of wearable or drone applications. Sensor networks will very likely play a key role in future estimates of human health impacts of pollutants, in particular particulate matter (PM), and will allow for the better characterization of pollutant sources and source regions.We will present measurements from an assortment of sensors, costing $20-$700, that have been used to measure air pollution in the US, India, and China with a focus on estimating PM concentrations. Their performance has been evaluated in these very different settings with low concentrations seen in the US (up to approximately 20 ug m-3) and much higher concentrations measured in India and China (up to approximately 300 ug m-3). Based on these studies the optimal concentration ranges of these sensors have been determined. Used in conjunction with data from a carbon dioxide sensor, emissions factors were estimated in some of the locations. In addition temperature and humidity sensors can be used to calculate c
Monitoring urban air quality using a high-density network of low-cost sensor nodes in Oslo, Norway.
NASA Astrophysics Data System (ADS)
Castell, Nuria; Schneider, Philipp; Vogt, Matthias; Dauge, Franck R.; Lahoz, William; Bartonova, Alena
2017-04-01
Urban air quality represents a major public health burden and is a long-standing concern to citizens. Air pollution is associated with a range of diseases, symptoms and conditions that impair health and quality of life. In Oslo, traffic, especially exhaust from heavy-duty and private diesel vehicles and dust resuspension from studded tyres, together with wood burning in winter, are the main sources of pollution. Norway, as part of the European Economic Area, is obliged to comply with the European air quality regulations and ensure clean air. Despite this, Oslo has exceeded both the NO2 and PM10 thresholds for health protection defined in the Directive 2008/50/EC. The air quality in the Oslo area is continuously monitored in 12 compliance monitoring stations. These stations provide reliable and accurate data but their density is too low to provide a detailed spatial distribution of air quality. The emergence of low-cost nodes enables observations at high spatial resolution, providing the opportunity to enhance existing monitoring systems. However, the data generated by these nodes is significantly less accurate and precise than the data provided by reference equipment. We have conducted an evaluation of low-cost nodes to monitor NO2 and PM10, comparing the data collected with low-cost nodes against CEN (European Standardization Organization) reference analysers. During January and March 2016, a network of 24 nodes was deployed in Oslo. During January, high NO2 levels were observed for several days in a row coinciding with the formation of a thermal inversion. During March, we observed an episode with high PM10 levels due to road dust resuspension. Our results show that there is a major technical challenge associated with current commercial low-cost sensors, regarding the sensor robustness and measurement repeatability. Despite this, low-cost sensor nodes are able to reproduce the NO2 and PM10 variability. The data from the sensors was employed to generate detailed NO2 and PM10 air quality maps using a data fusion technique. This way we were able to offer localized air quality information for the city of Oslo. The outlook for commercial low-cost sensors is promising, and our results show that currently some sensors are already capable of providing coarse information about air quality, indicating if the air quality is good, moderate or if the air is heavily polluted. This type of information could be suitable for applications that aim to raise awareness, or engage the community by monitoring local air quality, as such applications do not require the same accuracy as scientific or regulatory monitoring.
Matthews, R; Turner, P J; McDonald, N J; Ermolaev, K; Manus, T; Shelby, R A; Steindorf, M
2008-01-01
This paper describes a compact, lightweight and ultra-low power ambulatory wireless EEG system based upon QUASAR's innovative noninvasive bioelectric sensor technologies. The sensors operate through hair without skin preparation or conductive gels. Mechanical isolation built into the harness permits the recording of high quality EEG data during ambulation. Advanced algorithms developed for this system permit real time classification of workload during subject motion. Measurements made using the EEG system during ambulation are presented, including results for real time classification of subject workload.
Low-cost carbon thick-film strain sensors for implantable applications
NASA Astrophysics Data System (ADS)
Gutierrez, Christian A.; Meng, Ellis
2010-09-01
The suitability of low-cost carbon thick-film strain sensors embedded within a biomedical grade silicone rubber (Silastic® MDX4-4210) for implantable applications is investigated. These sensors address the need for robust cost-effective implantable strain sensing technology for the closed loop operation of function-restoring neural prosthetic systems. Design, fabrication and characterization of the sensors are discussed in the context of the application to strain/fullness measurements of the urinary bladder as part of the neuroprosthetic treatment of lower urinary tract dysfunction. The fabrication process, utilizing off-the-shelf screen-printing materials, is convenient and cost effective while achieving resolutions down to 75 µm. This method can also be extended to produce multilayer embedded devices by superposition of different screen-printable materials. Uniaxial loading performance, temperature dependence and long-term soak testing are used to validate suitability for implantation while proof-of-concept operation (up to 40% strain) is demonstrated on a bench-top latex balloon bladder model.
Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride
NASA Technical Reports Server (NTRS)
Pilgrim, Jeffrey; Gonzales, Paula
2012-01-01
Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.
Validation of Underwater Sensor Package Using Feature Based SLAM
Cain, Christopher; Leonessa, Alexander
2016-01-01
Robotic vehicles working in new, unexplored environments must be able to locate themselves in the environment while constructing a picture of the objects in the environment that could act as obstacles that would prevent the vehicles from completing their desired tasks. In enclosed environments, underwater range sensors based off of acoustics suffer performance issues due to reflections. Additionally, their relatively high cost make them less than ideal for usage on low cost vehicles designed to be used underwater. In this paper we propose a sensor package composed of a downward facing camera, which is used to perform feature tracking based visual odometry, and a custom vision-based two dimensional rangefinder that can be used on low cost underwater unmanned vehicles. In order to examine the performance of this sensor package in a SLAM framework, experimental tests are performed using an unmanned ground vehicle and two feature based SLAM algorithms, the extended Kalman filter based approach and the Rao-Blackwellized, particle filter based approach, to validate the sensor package. PMID:26999142
Low cost Earth attitude sensor
NASA Astrophysics Data System (ADS)
Liberati, Fabrizio; Perrotta, Giorgio; Verzegnassi, Fulvia
2017-11-01
A patent-pending, low-cost, moderate performance, Earth Attitude Sensor for LEO satellites is described in this paper. The paper deals with the system concepts, the technology adopted and the simulation results. The sensor comprises three or four narrow field of view mini telescopes pointed towards the Earth edge to detect and measure the variation of the off-nadir angle of the Earth-to-black sky transition using thermopile detectors suitably placed in the foci of the optical min telescopes. The system's innovation consists in the opto-mechanical configuration adopted that is sturdy and has no moving parts being , thus, inherently reliable. In addition, with a view to reducing production costs, the sensor does without hi-rel and is instead mainly based on COTS parts suitably chosen. Besides it is flexible and can be adapted to perform attitude measurement onboard spacecraft flying in orbits other than LEO with a minimum of modifications to the basic design. At present the sensor is under development by IMT and OptoService.
Atomic magnetometer for human magnetoencephalograpy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwindt, Peter; Johnson, Cort N.
2010-12-01
We have developed a high sensitivity (<5 fTesla/{radical}Hz), fiber-optically coupled magnetometer to detect magnetic fields produced by the human brain. This is the first demonstration of a noncryogenic sensor that could replace cryogenic superconducting quantum interference device (SQUID) magnetometers in magnetoencephalography (MEG) and is an important advance in realizing cost-effective MEG. Within the sensor, a rubidium vapor is optically pumped with 795 laser light while field-induced optical rotations are measured with 780 nm laser light. Both beams share a single optical axis to maximize simplicity and compactness. In collaboration with neuroscientists at The Mind Research Network in Albuquerque, NM, themore » evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer and a commercial SQUID-based MEG system with signals comparing favorably. Multi-sensor operation has been demonstrated with two AMs placed on opposite sides of the head. Straightforward miniaturization would enable high-density sensor arrays for whole-head magnetoencephalography.« less
Low-cost mobile air pollution monitoring in urban environments: a pilot study in Lubbock, Texas.
McKercher, Grant R; Vanos, Jennifer K
2018-06-01
The complex nature of air pollution in urban areas prevents traditional monitoring techniques from obtaining measurements representative of true human exposure. The current study assessed the capability of low-cost mobile monitors to acquire useful data in a city without a monitoring network in place (Lubbock, Texas) using a bicycle platform. The monitoring campaign resulted in 30 days of data along a 13.4 km fixed concentric route. Due to high sensitivities to airflow, the apparent wind velocity was accounted for throughout the route. The data were also normalized into percentiles in order to visualize spatial patterns. The highest estimated pollution levels were located near frequently busy intersections and roads; however, sensor issues resulted in lower confidence. Additional research is needed concerning the appropriate use of low-cost metal oxide sensors for citizen science applications, as measurements can be misleading if the user is unaware of sensors specifications. The simultaneous use of several low-cost mobile platforms, rather than a single platform, as well as the use of high-end cases, are recommended to create a more robust spatial analysis. The issues addressed from this research are important to understand for accurate and beneficial application of low-cost gaseous monitors for citizen science.
Sensor Suitcase: Portable System for Increasing Building Energy Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
PNNL's Sensor Suitcase does an energy assessment of small buildings, enabling building owners to see which low-cost, energy-saving modifications would give them the best payoff. Implementing the recommended changes typically means 10% energy cost savings per small building. No other product provides such easy-to-use, expert-guided capabilities, and at half the cost of a typical energy assessment.
NASA Astrophysics Data System (ADS)
Scholz, L. T.; Bierer, B.; Ortiz Perez, A.; Woellenstein, J.; Sachs, T.; Palzer, S.
2016-12-01
The determination of carbon dioxide (CO2) fluxes between ecosystems and the atmosphere is crucial for understanding ecological processes on regional and global scales. High quality data sets with full uncertainty estimates are needed to evaluate model simulations. However, current flux monitoring techniques are unsuitable to provide reliable data of a large area at both a detailed level and an appropriate resolution, at best in combination with a high sampling rate. Currently used sensing technologies, such as non-dispersive infrared (NDIR) gas analyzers, cannot be deployed in large numbers to provide high spatial resolution due to their costs and complex maintenance requirements. Here, we propose a novel CO2 measurement system, whose gas sensing unit is made up of low-cost, low-power consuming components only, such as an IR-LED and a photoacoustic detector. The sensor offers a resolution of < 50 ppm in the interesting concentration range up to 5000 ppm and an almost linear and fast sensor response of just a few seconds. Since the sensor can be applied in-situ without special precautions, it allows for environmental monitoring in a non-invasive way. Its low energy consumption enables long-term measurements. The low overall costs favor the manufacturing in large quantities. This allows the operation of multiple sensors at a reasonable price and thus provides concentration measurements at any desired spatial coverage and at high temporal resolution. With appropriate 3D configuration of the units, vertical and horizontal fluxes can be determined. By applying a closely meshed wireless sensor network, inhomogeneities as well as CO2 sources and sinks in the lower atmosphere can be monitored. In combination with sensors for temperature, pressure and humidity, our sensor paves the way towards the reliable and extensive monitoring of ecosystem-atmosphere exchange rates. The technique can also be easily adapted to other relevant greenhouse gases.
High-sensitivity explosives detection using dual-excitation-wavelength resonance-Raman detector
NASA Astrophysics Data System (ADS)
Yellampalle, Balakishore; McCormick, William B.; Wu, Hai-Shan; Sluch, Mikhail; Martin, Robert; Ice, Robert V.; Lemoff, Brian
2014-05-01
A key challenge for standoff explosive sensors is to distinguish explosives, with high confidence, from a myriad of unknown background materials that may have interfering spectral peaks. To meet this challenge a sensor needs to exhibit high specificity and high sensitivity in detection at low signal-to-noise ratio levels. We had proposed a Dual-Excitation- Wavelength Resonance-Raman Detector (DEWRRED) to address this need. In our previous work, we discussed various components designed at WVHTCF for a DEWRRED sensor. In this work, we show a completely assembled laboratory prototype of a DEWRRED sensor and utilize it to detect explosives from two standoff distances. The sensor system includes two novel, compact CW deep-Ultraviolet (DUV) lasers, a compact dual-band high throughput DUV spectrometer, and a highly-sensitive detection algorithm. We choose DUV excitation because Raman intensities from explosive traces are enhanced and fluorescence and solar background are not present. The DEWRRED technique exploits the excitation wavelength dependence of Raman signal strength, arising from complex interplay of resonant enhancement, self-absorption and laser penetration depth. We show measurements from >10 explosives/pre-cursor materials at different standoff distances. The sensor showed high sensitivity in explosive detection even when the signalto- noise ratio was close to one (~1.6). We measured receiver-operating-characteristics, which show a clear benefit in using the dual-excitation-wavelength technique as compared to a single-excitation-wavelength technique. Our measurements also show improved specificity using the amplitude variation information in the dual-excitation spectra.
Electronic Tongue for Quantitation of Contaminants in Water
NASA Technical Reports Server (NTRS)
Buehler, Marlin; Kuhlman, Gregory
2004-01-01
An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.
Community Air Sensor Network Project: Lower Cost, Continuous Ambient Monitoring Methods
This is an extended abstract that will be part of the peer-reviewed proceedings of the AWMA annual meeting in 2015. The extended abstract covers preliminary results from the CAIRSENSE project, which involves testing low cost sensors at an NCore site in Atlanta, GA.
Regulatory Considerations of Lower Cost Air Pollution Sensor Data Performance
Low-cost, portable air quality sensors could be the next generation of air monitoring, however, this nascent technology is not without risk. This article looks at how the U.S. Environmental Protection Agency (EPA) uses air monitoring data, the procedures followed to ensure and a...
Low-Power, Chip-Scale, Carbon Dioxide Gas Sensors for Spacesuit Monitoring
NASA Technical Reports Server (NTRS)
Rani, Asha; Shi, Chen; Thomson, Brian; Debnath, Ratan; Wen, Boamei; Motayed, Abhishek; Chullen, Cinda
2018-01-01
N5 Sensors, Inc. through a Small Business Technology Transfer (STTR) contract award has been developing ultra-small, low-power carbon dioxide (CO2) gas sensors, suited for monitoring CO2 levels inside NASA spacesuits. Due to the unique environmental conditions within the spacesuits, such as high humidity, large temperature swings, and operating pressure swings, measurement of key gases relevant to astronaut's safety and health such as(CO2), is quite challenging. Conventional non-dispersive infrared absorption based CO2 sensors present challenges inside the spacesuits due to size, weight, and power constraints, along with the ability to sense CO2 in a high humidity environment. Unique chip-scale, nanoengineered chemiresistive gas-sensing architecture has been developed for this application, which can be operated in a typical space-suite environmental conditions. Unique design combining the selective adsorption properties of the nanophotocatalytic clusters of metal-oxides and metals, provides selective detection of CO2 in high relative humidity conditions. All electronic design provides a compact and low-power solution, which can be implemented for multipoint detection of CO2 inside the spacesuits. This paper will describe the sensor architecture, development of new photocatalytic material for better sensor response, and advanced structure for better sensitivity and shorter response times.
Convert a low-cost sensor to a colorimeter using an improved regression method
NASA Astrophysics Data System (ADS)
Wu, Yifeng
2008-01-01
Closed loop color calibration is a process to maintain consistent color reproduction for color printers. To perform closed loop color calibration, a pre-designed color target should be printed, and automatically measured by a color measuring instrument. A low cost sensor has been embedded to the printer to perform the color measurement. A series of sensor calibration and color conversion methods have been developed. The purpose is to get accurate colorimetric measurement from the data measured by the low cost sensor. In order to get high accuracy colorimetric measurement, we need carefully calibrate the sensor, and minimize all possible errors during the color conversion. After comparing several classical color conversion methods, a regression based color conversion method has been selected. The regression is a powerful method to estimate the color conversion functions. But the main difficulty to use this method is to find an appropriate function to describe the relationship between the input and the output data. In this paper, we propose to use 1D pre-linearization tables to improve the linearity between the input sensor measuring data and the output colorimetric data. Using this method, we can increase the accuracy of the regression method, so as to improve the accuracy of the color conversion.
ERIC Educational Resources Information Center
McNeal, McKenzie, III.
2012-01-01
Current networking architectures and communication protocols used for Wireless Sensor Networks (WSNs) have been designed to be energy efficient, low latency, and long network lifetime. One major issue that must be addressed is the security in data communication. Due to the limited capabilities of low cost and small sized sensor nodes, designing…
2009-09-01
with the flexibility provided by a wireless sensor network , could provide such enhancements. The objective of this research was to explore the...feasibility of remote management and control of a low-power/low-cost wireless sensor network by implementing a point-to-point wireless network utilizing IEEE
NASA Astrophysics Data System (ADS)
Díaz, Camilo A. R.; Marques, Carlos A. F.; Domingues, M. Fátima F.; Ribeiro, Moisés. R. N.; Neto, Anselmo F.; Pontes, Maria J.; André, Paulo S.; Antunes, Paulo F. C.
2018-02-01
This paper presents a simple, compact, stable and inexpensive in-line solution based on catastrophic fuse effect micro-cavity interferometers for edge-filter strain interrogation of a fiber Bragg grating sensor. By using a commercial spliced machine and recycling damage fiber for the catastrophic fuse effect it is possible to construct a micro-cavity with high contrast of more than 20dB, and acceptable half free spectra range (FSR) around 13nm of interrogation range. The strain from 0 to 1440μStrain of the FBG sensor is measured with evidences of high repeatability and stability. Future work will investigate the use of the proposed method for applications requiring higher interrogation rates.
ERIC Educational Resources Information Center
Wolf, Walter A., Ed.
1976-01-01
Presents three brief articles that consider the recovery of silver from film, field trips as a supplement to science major general chemistry laboratory, and the construction of a low-cost colorimeter. (MLH)