ERIC Educational Resources Information Center
Putten, Jim Vander; Nolen, Amanda L.
2010-01-01
This study compared qualitative research results obtained by manual constant comparative analysis with results obtained by computer software analysis of the same data. An investigated about issues of trustworthiness and accuracy ensued. Results indicated that the inductive constant comparative data analysis generated 51 codes and two coding levels…
A novel comparator featured with input data characteristic
NASA Astrophysics Data System (ADS)
Jiang, Xiaobo; Ye, Desheng; Xu, Xiangmin; Zheng, Shuai
2016-03-01
Two types of low-power asynchronous comparators featured with input data statistical characteristic are proposed in this article. The asynchronous ripple comparator stops comparing at the first unequal bit but delivers the result to the least significant bit. The pre-stop asynchronous comparator can completely stop comparing and obtain results immediately. The proposed and contrastive comparators were implemented in SMIC 0.18 μm process with different bit widths. Simulation shows that the proposed pre-stop asynchronous comparator features the lowest power consumption, shortest average propagation delay and highest area efficiency among the comparators. Data path of low-density parity check decoder using the proposed pre-stop asynchronous comparators are most power efficient compared with other data paths with synthesised, clock gating and bitwise competition logic comparators.
McHale, Michael R.; McChesney, Dennis
2007-01-01
In 2003, a study was conducted to evaluate the accuracy and precision of 10 laboratories that analyze water-quality samples for phosphorus concentrations in the Catskill Mountain region of New York State. Many environmental studies in this region rely on data from these different laboratories for water-quality analyses, and the data may be used in watershed modeling and management decisions. Therefore, it is important to determine whether the data reported by these laboratories are of comparable accuracy and precision. Each laboratory was sent 12 samples for triplicate analysis for total phosphorus, total dissolved phosphorus, and soluble reactive phosphorus. Eight of these laboratories reported results that met comparability criteria for all samples; the remaining two laboratories met comparability criteria for only about half of the analyses. Neither the analytical method used nor the sample concentration ranges appeared to affect the comparability of results. The laboratories whose results were comparable gave consistently comparable results throughout the concentration range analyzed, and the differences among methods did not diminish comparability. All laboratories had high data precision as indicated by sample triplicate results. In addition, the laboratories consistently reported total phosphorus values greater than total dissolved phosphorus values, and total dissolved phosphorus values greater than soluble reactive phosphorus values, as would be expected. The results of this study emphasize the importance of regular laboratory participation in sample-exchange programs.
Question analysis for Indonesian comparative question
NASA Astrophysics Data System (ADS)
Saelan, A.; Purwarianti, A.; Widyantoro, D. H.
2017-01-01
Information seeking is one of human needs today. Comparing things using search engine surely take more times than search only one thing. In this paper, we analyzed comparative questions for comparative question answering system. Comparative question is a question that comparing two or more entities. We grouped comparative questions into 5 types: selection between mentioned entities, selection between unmentioned entities, selection between any entity, comparison, and yes or no question. Then we extracted 4 types of information from comparative questions: entity, aspect, comparison, and constraint. We built classifiers for classification task and information extraction task. Features used for classification task are bag of words, whether for information extraction, we used lexical, 2 previous and following words lexical, and previous label as features. We tried 2 scenarios: classification first and extraction first. For classification first, we used classification result as a feature for extraction. Otherwise, for extraction first, we used extraction result as features for classification. We found that the result would be better if we do extraction first before classification. For the extraction task, classification using SMO gave the best result (88.78%), while for classification, it is better to use naïve bayes (82.35%).
Deploying and sharing U-Compare workflows as web services
2013-01-01
Background U-Compare is a text mining platform that allows the construction, evaluation and comparison of text mining workflows. U-Compare contains a large library of components that are tuned to the biomedical domain. Users can rapidly develop biomedical text mining workflows by mixing and matching U-Compare’s components. Workflows developed using U-Compare can be exported and sent to other users who, in turn, can import and re-use them. However, the resulting workflows are standalone applications, i.e., software tools that run and are accessible only via a local machine, and that can only be run with the U-Compare platform. Results We address the above issues by extending U-Compare to convert standalone workflows into web services automatically, via a two-click process. The resulting web services can be registered on a central server and made publicly available. Alternatively, users can make web services available on their own servers, after installing the web application framework, which is part of the extension to U-Compare. We have performed a user-oriented evaluation of the proposed extension, by asking users who have tested the enhanced functionality of U-Compare to complete questionnaires that assess its functionality, reliability, usability, efficiency and maintainability. The results obtained reveal that the new functionality is well received by users. Conclusions The web services produced by U-Compare are built on top of open standards, i.e., REST and SOAP protocols, and therefore, they are decoupled from the underlying platform. Exported workflows can be integrated with any application that supports these open standards. We demonstrate how the newly extended U-Compare enhances the cross-platform interoperability of workflows, by seamlessly importing a number of text mining workflow web services exported from U-Compare into Taverna, i.e., a generic scientific workflow construction platform. PMID:23419017
Comparison to What End? Maximizing the Potential of Comparative Education Research
ERIC Educational Resources Information Center
Fairbrother, Gregory P.
2005-01-01
This article attends to comparative education scholars' calls for more dialogue on the contribution of theory to comparative education research. It first presents the results of a review of a small sample of articles from comparative education related journals that elicited the purposes of their comparative research strategies in terms of…
Code of Federal Regulations, 2012 CFR
2012-10-01
... assignment for authorizations issued as a result of a comparative renewal proceeding. 22.943 Section 22.943... authorizations issued as a result of a comparative renewal proceeding. Except as otherwise provided in this... of a comparative renewal proceeding until the system has provided service to subscribers for at least...
Code of Federal Regulations, 2014 CFR
2014-10-01
... assignment for authorizations issued as a result of a comparative renewal proceeding. 22.943 Section 22.943... authorizations issued as a result of a comparative renewal proceeding. Except as otherwise provided in this... of a comparative renewal proceeding until the system has provided service to subscribers for at least...
Code of Federal Regulations, 2013 CFR
2013-10-01
... assignment for authorizations issued as a result of a comparative renewal proceeding. 22.943 Section 22.943... authorizations issued as a result of a comparative renewal proceeding. Except as otherwise provided in this... of a comparative renewal proceeding until the system has provided service to subscribers for at least...
Code of Federal Regulations, 2010 CFR
2010-10-01
... assignment for authorizations issued as a result of a comparative renewal proceeding. 22.943 Section 22.943... authorizations issued as a result of a comparative renewal proceeding. Except as otherwise provided in this... of a comparative renewal proceeding until the system has provided service to subscribers for at least...
Code of Federal Regulations, 2011 CFR
2011-10-01
... assignment for authorizations issued as a result of a comparative renewal proceeding. 22.943 Section 22.943... authorizations issued as a result of a comparative renewal proceeding. Except as otherwise provided in this... of a comparative renewal proceeding until the system has provided service to subscribers for at least...
Bartneck, Christoph; Duenser, Andreas; Moltchanova, Elena; Zawieska, Karolina
2015-01-01
Computer and internet based questionnaires have become a standard tool in Human-Computer Interaction research and other related fields, such as psychology and sociology. Amazon’s Mechanical Turk (AMT) service is a new method of recruiting participants and conducting certain types of experiments. This study compares whether participants recruited through AMT give different responses than participants recruited through an online forum or recruited directly on a university campus. Moreover, we compare whether a study conducted within AMT results in different responses compared to a study for which participants are recruited through AMT but which is conducted using an external online questionnaire service. The results of this study show that there is a statistical difference between results obtained from participants recruited through AMT compared to the results from the participant recruited on campus or through online forums. We do, however, argue that this difference is so small that it has no practical consequence. There was no significant difference between running the study within AMT compared to running it with an online questionnaire service. There was no significant difference between results obtained directly from within AMT compared to results obtained in the campus and online forum condition. This may suggest that AMT is a viable and economical option for recruiting participants and for conducting studies as setting up and running a study with AMT generally requires less effort and time compared to other frequently used methods. We discuss our findings as well as limitations of using AMT for empirical studies. PMID:25876027
Bartneck, Christoph; Duenser, Andreas; Moltchanova, Elena; Zawieska, Karolina
2015-01-01
Computer and internet based questionnaires have become a standard tool in Human-Computer Interaction research and other related fields, such as psychology and sociology. Amazon's Mechanical Turk (AMT) service is a new method of recruiting participants and conducting certain types of experiments. This study compares whether participants recruited through AMT give different responses than participants recruited through an online forum or recruited directly on a university campus. Moreover, we compare whether a study conducted within AMT results in different responses compared to a study for which participants are recruited through AMT but which is conducted using an external online questionnaire service. The results of this study show that there is a statistical difference between results obtained from participants recruited through AMT compared to the results from the participant recruited on campus or through online forums. We do, however, argue that this difference is so small that it has no practical consequence. There was no significant difference between running the study within AMT compared to running it with an online questionnaire service. There was no significant difference between results obtained directly from within AMT compared to results obtained in the campus and online forum condition. This may suggest that AMT is a viable and economical option for recruiting participants and for conducting studies as setting up and running a study with AMT generally requires less effort and time compared to other frequently used methods. We discuss our findings as well as limitations of using AMT for empirical studies.
Callan, Richard S; Cooper, Jeril R; Young, Nancy B; Mollica, Anthony G; Furness, Alan R; Looney, Stephen W
2015-06-01
The problems associated with intra- and interexaminer reliability when assessing preclinical performance continue to hinder dental educators' ability to provide accurate and meaningful feedback to students. Many studies have been conducted to evaluate the validity of utilizing various technologies to assist educators in achieving that goal. The purpose of this study was to compare two different versions of E4D Compare software to determine if either could be expected to deliver consistent and reliable comparative results, independent of the individual utilizing the technology. Five faculty members obtained E4D digital images of students' attempts (sample model) at ideal gold crown preparations for tooth #30 performed on typodont teeth. These images were compared to an ideal (master model) preparation utilizing two versions of E4D Compare software. The percent correlations between and within these faculty members were recorded and averaged. The intraclass correlation coefficient was used to measure both inter- and intrarater agreement among the examiners. The study found that using the older version of E4D Compare did not result in acceptable intra- or interrater agreement among the examiners. However, the newer version of E4D Compare, when combined with the Nevo scanner, resulted in a remarkable degree of agreement both between and within the examiners. These results suggest that consistent and reliable results can be expected when utilizing this technology under the protocol described in this study.
Results of the 1979 NACUBO Comparative Performance Study and Investment Questionnaire.
ERIC Educational Resources Information Center
Dresner, Bruce M.
Results of the 1979 Comparative Performance Study of the National Association of College and Business Officers are presented. The study is designed to aid administrators in evaluating the performance of their investment pools. The report covers comparative performance information and related investment performance statistics and other endowment…
NASA Astrophysics Data System (ADS)
Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł
2018-01-01
The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.
Deploying and sharing U-Compare workflows as web services.
Kontonatsios, Georgios; Korkontzelos, Ioannis; Kolluru, Balakrishna; Thompson, Paul; Ananiadou, Sophia
2013-02-18
U-Compare is a text mining platform that allows the construction, evaluation and comparison of text mining workflows. U-Compare contains a large library of components that are tuned to the biomedical domain. Users can rapidly develop biomedical text mining workflows by mixing and matching U-Compare's components. Workflows developed using U-Compare can be exported and sent to other users who, in turn, can import and re-use them. However, the resulting workflows are standalone applications, i.e., software tools that run and are accessible only via a local machine, and that can only be run with the U-Compare platform. We address the above issues by extending U-Compare to convert standalone workflows into web services automatically, via a two-click process. The resulting web services can be registered on a central server and made publicly available. Alternatively, users can make web services available on their own servers, after installing the web application framework, which is part of the extension to U-Compare. We have performed a user-oriented evaluation of the proposed extension, by asking users who have tested the enhanced functionality of U-Compare to complete questionnaires that assess its functionality, reliability, usability, efficiency and maintainability. The results obtained reveal that the new functionality is well received by users. The web services produced by U-Compare are built on top of open standards, i.e., REST and SOAP protocols, and therefore, they are decoupled from the underlying platform. Exported workflows can be integrated with any application that supports these open standards. We demonstrate how the newly extended U-Compare enhances the cross-platform interoperability of workflows, by seamlessly importing a number of text mining workflow web services exported from U-Compare into Taverna, i.e., a generic scientific workflow construction platform.
COMPARE : a method for analyzing investment alternatives in industrial wood and bark energy systems
Peter J. Ince
1983-01-01
COMPARE is a FORTRAN computer program resulting from a study to develop methods for comparative economic analysis of alternatives in industrial wood and bark energy systems. COMPARE provides complete guidelines for economic analysis of wood and bark energy systems. As such, COMPARE can be useful to those who have only basic familiarity with investment analysis of wood...
Henk, Henry J; Li, Xiaoyan; Becker, Laura K; Xu, Hairong; Gong, Qi; Deeter, Robert G; Barron, Richard L
2015-01-01
To examine the impact of research design on results in two published comparative effectiveness studies. Guidelines for comparative effectiveness research have recommended incorporating disease process in study design. Based on the recommendations, we develop a checklist of considerations and apply the checklist in review of two published studies on comparative effectiveness of colony-stimulating factors. Both studies used similar administrative claims data, but different methods, which resulted in directionally different estimates. Major design differences between the two studies include: whether the timing of intervention in disease process was identified and whether study cohort and outcome assessment period were defined based on this temporal relationship. Disease process and timing of intervention should be incorporated into the design of comparative effectiveness studies.
NASA Astrophysics Data System (ADS)
Salleh, S. A.; Rahman, A. S. A. Abd; Othman, A. N.; Mohd, W. M. N. Wan
2018-02-01
As different approach produces different results, it is crucial to determine the methods that are accurate in order to perform analysis towards the event. This research aim is to compare the Rank Reciprocal (MCDM) and Artificial Neural Network (ANN) analysis techniques in determining susceptible zones of landslide hazard. The study is based on data obtained from various sources such as local authority; Dewan Bandaraya Kuala Lumpur (DBKL), Jabatan Kerja Raya (JKR) and other agencies. The data were analysed and processed using Arc GIS. The results were compared by quantifying the risk ranking and area differential. It was also compared with the zonation map classified by DBKL. The results suggested that ANN method gives better accuracy compared to MCDM with 18.18% higher accuracy assessment of the MCDM approach. This indicated that ANN provides more reliable results and it is probably due to its ability to learn from the environment thus portraying realistic and accurate result.
A Comparable Worth Cyclone Is Swirling toward Your Schools.
ERIC Educational Resources Information Center
Zakariya, Sally Banks
1985-01-01
Describes the concept of comparable worth, discusses opposing views concerning whether inequities in pay are results of discrimination, considers efforts to determine the comparability of jobs, including teaching, notes the possible impact of implementing comparable worth legislation, and cites developments in state legislation and local school…
Wheat productivity estimates using LANDSAT data
NASA Technical Reports Server (NTRS)
Nalepka, R. F.; Colwell, J. E. (Principal Investigator); Rice, D. P.; Bresnahan, P. A.
1977-01-01
The author has identified the following significant results. Large area LANDSAT yield estimates were generated. These results were compared with estimates computed using a meteorological yield model (CCEA). Both of these estimates were compared with Kansas Crop and Livestock Reporting Service (KCLRS) estimates of yield, in an attempt to assess the relative and absolute accuracy of the LANDSAT and CCEA estimates. Results were inconclusive. A large area direct wheat prediction procedure was implemented. Initial results have produced a wheat production estimate comparable with the KCLRS estimate.
NASA Technical Reports Server (NTRS)
Mei, Chuh; Pates, Carl S., III
1994-01-01
A coupled boundary element (BEM)-finite element (FEM) approach is presented to accurately model structure-acoustic interaction systems. The boundary element method is first applied to interior, two and three-dimensional acoustic domains with complex geometry configurations. Boundary element results are very accurate when compared with limited exact solutions. Structure-interaction problems are then analyzed with the coupled FEM-BEM method, where the finite element method models the structure and the boundary element method models the interior acoustic domain. The coupled analysis is compared with exact and experimental results for a simplistic model. Composite panels are analyzed and compared with isotropic results. The coupled method is then extended for random excitation. Random excitation results are compared with uncoupled results for isotropic and composite panels.
Euler, André; Obmann, Markus M; Szucs-Farkas, Zsolt; Mileto, Achille; Zaehringer, Caroline; Falkowski, Anna L; Winkel, David J; Marin, Daniele; Stieltjes, Bram; Krauss, Bernhard; Schindera, Sebastian T
2018-02-19
To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNR liv ) and the portal vein (CNR pv ). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p < 0.001). Composed images yielded higher CNR liv over single-energy images (23.4 vs. 20.9; p < 0.001), whereas CNR pv was significantly lower (3.5 vs. 5.2; p < 0.001). Monoenergetic images overcame this inferiority in CNR pv and achieved similar results compared to single-energy images (5.1 vs. 5.2; p > 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOM liv was highest for SF-CI. FOM pv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p < 0.022). The combined use of split-filter dual-energy CT images provides comparable objective and subjective image quality at lower radiation dose compared to single-energy CT with ATVS. • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.
Preliminary analysis of one year long space climate simulation
NASA Astrophysics Data System (ADS)
Facsko, G.; Honkonen, I. J.; Juusola, L.; Viljanen, A.; Vanhamäki, H.; Janhunen, P.; Palmroth, M.; Milan, S. E.
2013-12-01
One full year (155 Cluster orbits, from January 29, 2002 to February 2, 2003) is simulated using the Grand Unified Magnetosphere Ionosphere Coupling simulation (GUMICS) in the European Cluster Assimilation Technology project (ECLAT). This enables us to study the performance of a global magnetospheric model in an unprecedented scale both in terms of the amount of available observations and the length of the timeseries that can be compared. The solar wind for the simulated period, obtained from OMNIWeb, is used as input to GUMICS. We present an overview of various comparisons of GUMICS results to observations for the simulated year. Results along the Cluster reference spacecraft orbit to are compared to Cluster measurements. The Cross Polar Cap Potential (CPCP) results are compared to SuperDARN measurements. The IMAGE electrojet indicators (IU, IL) calculated from the ionospheric currents of GUMICS are compared to observations. Finally, Geomagnetically Induced Currents (GIC) calculated from GUMICS results along the Finnish mineral gas pipeline at Mätsälä are also compared to measurements.
2018-03-01
Results are compared to a previous study using a similar design of experiments but different simulation software. The baseline scenario for exploring the...behaviors are mimicked in this research, enabling Solem’s MANA results to be compared to our LITMUS’ results. By design , the principal difference...missions when using the second order NOLH, and compares favorably with the over six million in the full factorial design . 3. Advantages of Cluster
Validation of Interannual Differences of AIRS Monthly Mean Parameters
NASA Technical Reports Server (NTRS)
Susskind, Joel; Iredell, Lena; Keita, Fricky; Molnar, Gyula
2005-01-01
Monthly mean fields of select geophysical parameters derived from analysis of AIRS/AMSU data, and their interannual differences, are shown and compared with analogous fields derived from other sources. All AIRS fields are derived using the AIRS Science Team Version 4 algorithm. Monthly mean results are shown for January 2004, as are interannual differences between January 2004 and January 2003. AIRS temperature and water vapor profile fields are compared with monthly mean collocated ECMWF 3 hour forecast and monthly mean TOVS Pathfinder Path A data. AIRS Tropospheric and Stratospheric coarse climate indicators are compared with analogous MSU products derived by Spencer and christy and found in the TOVS Pathfinder Path A data set. Total ozone is compared with results produced by TOMS. OLR is compared with OLR derived using CERES data and found in the TOVS Pathfinder Path A data set. AIRS results agree well in all cases, especially in the interannual difference sense.
Yan, Xiaoyu; Lowe, Philip J.; Fink, Martin; Berghout, Alexander; Balser, Sigrid; Krzyzanski, Wojciech
2012-01-01
The aim of this study was to develop an integrated pharmacokinetic and pharmacodynamic (PK/PD) model and assess the comparability between epoetin alfa HEXAL/Binocrit (HX575) and a comparator epoetin alfa by a model-based approach. PK/PD data—including serum drug concentrations, reticulocyte counts, red blood cells, and hemoglobin levels—were obtained from 2 clinical studies. In sum, 149 healthy men received multiple intravenous or subcutaneous doses of HX575 (100 IU/kg) and the comparator 3 times a week for 4 weeks. A population model based on pharmacodynamics-mediated drug disposition and cell maturation processes was used to characterize the PK/PD data for the 2 drugs. Simulations showed that due to target amount changes, total clearance may increase up to 2.4-fold as compared with the baseline. Further simulations suggested that once-weekly and thrice-weekly subcutaneous dosing regimens would result in similar efficacy. The findings from the model-based analysis were consistent with previous results using the standard noncompartmental approach demonstrating PK/PD comparability between HX575 and comparator. However, due to complexity of the PK/PD model, control of random effects was not straightforward. Whereas population PK/PD model-based analyses are suited for studying complex biological systems, such models have their limitations (statistical), and their comparability results should be interpreted carefully. PMID:22162538
ERIC Educational Resources Information Center
Ault, Hugh J.; Glendon, Mary Ann
1976-01-01
Discusses the rationale for teaching comparative law and describes techniques and results of experiments with two kinds of courses at Boston College Law School: (1) Comparative Legal Analysis, a perspective course, and (2) integration of comparative law as another dimension into courses in a particular subject matter area. (JT)
NASA Astrophysics Data System (ADS)
Fanjul-Vélez, Félix; de la Torre-Hernández, José María; Ortega-Quijano, Noé; Zueco-Gil, José Javier; Arce-Diego, José Luis
2009-07-01
In this work, we present clinical images of IVUS and OCT in the evaluation of pharmacological stent endothelization. These preliminary imaging results are analyzed and compared in order to determine the ability of these technologies to visualize relevant intravascular features of interest in interventional cardiology. The results enable to compare the performance of both techniques and to evaluate their potential for clinical purposes.
Peterson, Laurel M; Helweg-Larsen, Marie; Volpp, Kevin G; Kimmel, Stephen E
2012-01-01
Risk biases such as comparative optimism (thinking one is better off than similar others) and risk inaccuracy (misestimating one's risk compared to one's calculated risk) for health outcomes are common. Little research has investigated racial or socioeconomic differences in these risk biases. Results from a survey of individuals with poorly controlled hypertension (N=813) indicated that participants showed (1) comparative optimism for heart attack risk by underestimating their heart attack risk compared to similar others, and (2) risk inaccuracy by overestimating their heart attack risk compared to their calculated heart attack risk. More highly educated participants were more comparatively optimistic because they rated their personal risk as lower; education was not related to risk inaccuracy. Neither race nor the federal poverty level was related to risk biases. Worry partially mediated the relationship between education and personal risk. Results are discussed as they relate to the existing literature on risk perception.
Mori, V; Oliveira, M A; Vargas, M H M; da Cunha, A A; de Souza, R G; Pitrez, P M; Moriya, H T
2017-06-01
Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n = 8) and in a murine model of asthma (OVA) (n = 10). Then, we compared the results obtained by two different methods, using a commercial equipment (flexiVent-flexiWare 7.X; SCIREQ, Montreal, Canada) (FXV) and a wavetube method equipment (Sly et al 2003 J. Appl. Physiol. 94 1460-6) (WVT). We believe that the results from different methods may not be comparable. First, we compared the results performing a two-way analysis of variance (ANOVA) for the resistance, elastance and tissue damping. We found statistically significant differences in all CPM parameters, except for resistance, when comparing Control and OVA groups. When comparing devices, we found statistically significant differences in resistance, while differences in elastance were not observed. For tissue damping, the results from WVT were observed to be higher than those from FXV. Finally, when comparing the relative variation between the CPM parameters of the Control and OVA groups in both devices, no significant differences were observed for all parameters. We then conclude that this assessment can compensate the effect of using different cannulas. Furthermore, tissue damping differences between groups can be compensated, since bronchoconstrictors were not used. Therefore, we believe that relative variations in the results between groups can be a comparing parameter when using different equipment without bronchoconstrictor administration.
2015-01-01
Background Though cluster analysis has become a routine analytic task for bioinformatics research, it is still arduous for researchers to assess the quality of a clustering result. To select the best clustering method and its parameters for a dataset, researchers have to run multiple clustering algorithms and compare them. However, such a comparison task with multiple clustering results is cognitively demanding and laborious. Results In this paper, we present XCluSim, a visual analytics tool that enables users to interactively compare multiple clustering results based on the Visual Information Seeking Mantra. We build a taxonomy for categorizing existing techniques of clustering results visualization in terms of the Gestalt principles of grouping. Using the taxonomy, we choose the most appropriate interactive visualizations for presenting individual clustering results from different types of clustering algorithms. The efficacy of XCluSim is shown through case studies with a bioinformatician. Conclusions Compared to other relevant tools, XCluSim enables users to compare multiple clustering results in a more scalable manner. Moreover, XCluSim supports diverse clustering algorithms and dedicated visualizations and interactions for different types of clustering results, allowing more effective exploration of details on demand. Through case studies with a bioinformatics researcher, we received positive feedback on the functionalities of XCluSim, including its ability to help identify stably clustered items across multiple clustering results. PMID:26328893
Maruthingal, Sunith; Mohan, Dennis; Maroli, Ramesh Kumar; Alahmari, Ali; Alqahtani, Ahmed; Alsadoon, Mohammed
2015-01-01
Background: To compare 4% articaine and 2% lidocaine local anesthetics in achieving pulpal anesthesia of the lower first permanent molar teeth objectively, and to assess and compare lip and lingual mucosa numbness subjectively. Materials and Methods: All subjects received 1.7 ml of any one anesthetic in the mucobuccal fold adjacent to mandibular first molar teeth; the same individuals received the second infiltration at least 1 week after the first. Later, comparisons for pulpal anesthesia, lip and lingual mucosa numbness between these two anesthetics solutions were made. Results: Articaine showed significant results with P = 0.006 in achieving pulpal anesthesia objectively, when compared with lidocaine. Articaine also showed very high significant results subjectively with P = 0.0006 in achieving lip numbness, when compared with lidocaine. But the results in achieving lingual mucosa numbness with articaine subjectively was not significant with P = 0.01, when compared with lidocaine. Conclusion: Endodontic and operative treatments are one of the most common oral non-surgical procedures done under local anesthesia. The diversity of anesthetic substances currently available on the market requires dental professionals to assess the drug both by its pharmacokinetic and also by its clinical characteristics during dental treatments. Our study used 4% articaine, which is available in the market, for comparison with 2% lidocaine. Further studies are required to use an equal concentration of solutions to achieve more accurate results. PMID:26759799
Albert, R E
1983-01-01
Mammalian cell mutagenesis, transformation and skin tumorigenesis assays show similar results in comparing the potencies of diesel, coke oven, roofing tar and cigarette smoke particulates. These assay results are reasonably consistent with the comparative carcinogenic potencies of coke oven and roofing tar emissions as determined by epidemiological studies. The bacterial mutagenesis assay tends to show disproportionately high potencies, particularly with diesel particulates. Results to date encourage the approach to the assessment for carcinogenic risks from diesel emissions based on the use of epidemiological data on cancer induced by coke oven emissions, roofing tar particulates and cigarette smoke with the comparative potencies of these materials determined by in vivo and in vitro bioassays. PMID:6186481
ERIC Educational Resources Information Center
Hughes, John; Zhou, Chengfu; Petscher, Yaacov
2015-01-01
This report describes the results of a REL Southeast study comparing student success in online credit recovery and general courses taken online compared to traditional face-to-face courses. Credit recovery occurs when a student fails a course and then retakes the same course to earn high school credit. This research question was motivated by the…
Fenton, Susan H; Benigni, Mary Sue
2014-01-01
The transition from ICD-9-CM to ICD-10-CM/PCS is expected to result in longitudinal data discontinuities, as occurred with cause-of-death in 1999. The General Equivalence Maps (GEMs), while useful for suggesting potential maps do not provide guidance regarding the frequency of any matches. Longitudinal data comparisons can only be reliable if they use comparability ratios or factors which have been calculated using records coded in both classification systems. This study utilized 3,969 de-identified dually coded records to examine raw comparability ratios, as well as the comparability ratios between the Joint Commission Core Measures. The raw comparability factor results range from 16.216 for Nicotine dependence, unspecified, uncomplicated to 118.009 for Chronic obstructive pulmonary disease, unspecified. The Joint Commission Core Measure comparability factor results range from 27.15 for Acute Respiratory Failure to 130.16 for Acute Myocardial Infarction. These results indicate significant differences in comparability between ICD-9-CM and ICD-10-CM code assignment, including when the codes are used for external reporting such as the Joint Commission Core Measures. To prevent errors in decision-making and reporting, all stakeholders relying on longitudinal data for measure reporting and other purposes should investigate the impact of the conversion on their data.
NASA Astrophysics Data System (ADS)
Tátrai, Erika; Ranganathan, Sudarshan; Ferencz, Mária; Debuc, Delia Cabrera; Somfai, Gábor Márk
2011-05-01
Purpose: To compare thickness measurements between Fourier-domain optical coherence tomography (FD-OCT) and time-domain OCT images analyzed with a custom-built OCT retinal image analysis software (OCTRIMA). Methods: Macular mapping (MM) by StratusOCT and MM5 and MM6 scanning protocols by an RTVue-100 FD-OCT device are performed on 11 subjects with no retinal pathology. Retinal thickness (RT) and the thickness of the ganglion cell complex (GCC) obtained with the MM6 protocol are compared for each early treatment diabetic retinopathy study (ETDRS)-like region with corresponding results obtained with OCTRIMA. RT results are compared by analysis of variance with Dunnett post hoc test, while GCC results are compared by paired t-test. Results: A high correlation is obtained for the RT between OCTRIMA and MM5 and MM6 protocols. In all regions, the StratusOCT provide the lowest RT values (mean difference 43 +/- 8 μm compared to OCTRIMA, and 42 +/- 14 μm compared to RTVue MM6). All RTVue GCC measurements were significantly thicker (mean difference between 6 and 12 μm) than the GCC measurements of OCTRIMA. Conclusion: High correspondence of RT measurements is obtained not only for RT but also for the segmentation of intraretinal layers between FD-OCT and StratusOCT-derived OCTRIMA analysis. However, a correction factor is required to compensate for OCT-specific differences to make measurements more comparable to any available OCT device.
Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.
Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J
2018-05-01
To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Spatial attention does improve temporal discrimination.
Chica, Ana B; Christie, John
2009-02-01
It has recently been stated that exogenous attention impairs temporal-resolution tasks (Hein, Rolke, & Ulrich, 2006; Rolke, Dinkelbach, Hein, & Ulrich, 2008; Yeshurun, 2004; Yeshurun & Levy, 2003). In comparisons of performance on spatially cued trials versus neutral cued trials, the results have suggested that spatial attention decreases temporal resolution. However, when performance on cued and uncued trials has been compared in order to equate for cue salience, typically speed-accuracy trade-offs (SATs) have been observed, making the interpretation of the results difficult. In the present experiments, we aimed at studying the effect of spatial attention in temporal resolution while using a procedure to control for SATs. We controlled reaction times (RTs) by constraining the time to respond, so that response decisions would be made within comparable time windows. The results revealed that when RT was controlled, performance was impaired for cued trials as compared with neutral trials, replicating previous findings. However, when cued and uncued trials were compared, performance was actually improved for cued trials as compared with uncued trials. These results suggest that SAT effects may have played an important role in the previous studies, because when they were controlled and measured, the results reversed, revealing that exogenous attention does improve performance on temporal-resolution tasks.
ERIC Educational Resources Information Center
Poncy, Brian C.; Skinner, Christopher H.; Jaspers, Kathryn E.
2007-01-01
An adapted alternating treatments design was used to evaluate and compare the effects of two procedures designed to enhance math fact accuracy and fluency in an elementary student with low cognitive functioning. Results showed that although the cover, copy, compare (CCC) and the taped problems (TP) procedures both increased the student's math fact…
3D CFD Quantification of the Performance of a Multi-Megawatt Wind Turbine
NASA Astrophysics Data System (ADS)
Laursen, J.; Enevoldsen, P.; Hjort, S.
2007-07-01
This paper presents the results of 3D CFD rotor computations of a Siemens SWT-2.3-93 variable speed wind turbine with 45m blades. In the paper CFD is applied to a rotor at stationary wind conditions without wind shear, using the commercial multi-purpose CFD-solvers ANSYS CFX 10.0 and 11.0. When comparing modelled mechanical effects with findings from other models and measurements, good agreement is obtained. Similarly the computed force distributions compare very well, whereas some discrepancies are found when comparing with an in-house BEM model. By applying the reduced axial velocity method the local angle of attack has been derived from the CFD solutions, and from this knowledge and the computed force distributions, local airfoil profile coefficients have been computed and compared to BEM airfoil coefficients. Finally, the transition model of Langtry and Menter is tested on the rotor, and the results are compared with the results from the fully turbulent setup.
Crawford, Cindy; Boyd, Courtney; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Yang, EunMee; Zhang, Weimin; Buckenmaier, Chester; Buckenmaier, Pamela; Cambron, Jerrilyn; Deery, Christopher; Schwartz, Jan; Werner, Ruth; Whitridge, Pete
2016-01-01
Abstract Purpose Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life outcomes across all pain populations. Methods Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Results Sixty high quality and seven low quality studies were included in the review. Results demonstrate massage therapy effectively treats pain compared to sham [standardized mean difference (SMD) = −.44], no treatment (SMD = −1.14), and active (SMD = −0.26) comparators. Compared to active comparators, massage therapy was also beneficial for treating anxiety (SMD = −0.57) and health-related quality of life (SMD = 0.14). Conclusion Based on the evidence, massage therapy, compared to no treatment, should be strongly recommended as a pain management option. Massage therapy is weakly recommended for reducing pain, compared to other sham or active comparators, and improving mood and health-related quality of life, compared to other active comparators. Massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option are discussed. PMID:27165971
Causal cognition in human and nonhuman animals: a comparative, critical review.
Penn, Derek C; Povinelli, Daniel J
2007-01-01
In this article, we review some of the most provocative experimental results to have emerged from comparative labs in the past few years, starting with research focusing on contingency learning and finishing with experiments exploring nonhuman animals' understanding of causal-logical relations. Although the theoretical explanation for these results is often inchoate, a clear pattern nevertheless emerges. The comparative evidence does not fit comfortably into either the traditional associationist or inferential alternatives that have dominated comparative debate for many decades now. Indeed, the similarities and differences between human and nonhuman causal cognition seem to be much more multifarious than these dichotomous alternatives allow.
Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA
NASA Astrophysics Data System (ADS)
Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.
2018-03-01
Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.
Results of the 1978 NACUBO Comparative Performance Study and Investment Questionnaire.
ERIC Educational Resources Information Center
Dresner, Bruce M.
Information from the 1978 Comparative Performance Study and investment questionnaire conducted by the National Association of College and University Business Officers is presented. One hundred forty-four institutions provided information about 164 investment pools. The Comparative Performance Study provides participating institutions with…
Knowles, Jacky M; Garrett, Greg S; Gorstein, Jonathan; Kupka, Roland; Situma, Ruth; Yadav, Kapil; Yusufali, Rizwan; Pandav, Chandrakant; Aaron, Grant J
2017-01-01
Background: Household coverage with iodized salt was assessed in 10 countries that implemented Universal Salt Iodization (USI). Objective: The objective of this paper was to summarize household coverage data for iodized salt, including the relation between coverage and residence type and socioeconomic status (SES). Methods: A review was conducted of results from cross-sectional multistage household cluster surveys with the use of stratified probability proportional to size design in Bangladesh, Ethiopia, Ghana, India, Indonesia, Niger, the Philippines, Senegal, Tanzania, and Uganda. Salt iodine content was assessed with quantitative methods in all cases. The primary indicator of coverage was percentage of households that used adequately iodized salt, with an additional indicator for salt with some added iodine. Indicators of risk were SES and residence type. We used 95% CIs to determine significant differences in coverage. Results: National household coverage of adequately iodized salt varied from 6.2% in Niger to 97.0% in Uganda. For salt with some added iodine, coverage varied from 52.4% in the Philippines to 99.5% in Uganda. Coverage with adequately iodized salt was significantly higher in urban than in rural households in Bangladesh (68.9% compared with 44.3%, respectively), India (86.4% compared with 69.8%, respectively), Indonesia (59.3% compared with 51.4%, respectively), the Philippines (31.5% compared with 20.2%, respectively), Senegal (53.3% compared with 19.0%, respectively), and Tanzania (89.2% compared with 57.6%, respectively). In 7 of 8 countries with data, household coverage of adequately iodized salt was significantly higher in high- than in low-SES households in Bangladesh (58.8% compared with 39.7%, respectively), Ghana (36.2% compared with 21.5%, respectively), India (80.6% compared with 70.5%, respectively), Indonesia (59.9% compared with 45.6%, respectively), the Philippines (39.4% compared with 17.3%, respectively), Senegal (50.7% compared with 27.6%, respectively) and Tanzania (80.9% compared with 51.3%, respectively). Conclusions: Uganda has achieved USI. In other countries, access to iodized salt is inequitable. Quality control and regulatory enforcement of salt iodization remain challenging. Notable progress toward USI has been made in Ethiopia and India. Assessing progress toward USI only through household salt does not account for potentially iodized salt consumed through processed foods. PMID:28404840
Knowles, Jacky M; Garrett, Greg S; Gorstein, Jonathan; Kupka, Roland; Situma, Ruth; Yadav, Kapil; Yusufali, Rizwan; Pandav, Chandrakant; Aaron, Grant J
2017-05-01
Background: Household coverage with iodized salt was assessed in 10 countries that implemented Universal Salt Iodization (USI). Objective: The objective of this paper was to summarize household coverage data for iodized salt, including the relation between coverage and residence type and socioeconomic status (SES). Methods: A review was conducted of results from cross-sectional multistage household cluster surveys with the use of stratified probability proportional to size design in Bangladesh, Ethiopia, Ghana, India, Indonesia, Niger, the Philippines, Senegal, Tanzania, and Uganda. Salt iodine content was assessed with quantitative methods in all cases. The primary indicator of coverage was percentage of households that used adequately iodized salt, with an additional indicator for salt with some added iodine. Indicators of risk were SES and residence type. We used 95% CIs to determine significant differences in coverage. Results: National household coverage of adequately iodized salt varied from 6.2% in Niger to 97.0% in Uganda. For salt with some added iodine, coverage varied from 52.4% in the Philippines to 99.5% in Uganda. Coverage with adequately iodized salt was significantly higher in urban than in rural households in Bangladesh (68.9% compared with 44.3%, respectively), India (86.4% compared with 69.8%, respectively), Indonesia (59.3% compared with 51.4%, respectively), the Philippines (31.5% compared with 20.2%, respectively), Senegal (53.3% compared with 19.0%, respectively), and Tanzania (89.2% compared with 57.6%, respectively). In 7 of 8 countries with data, household coverage of adequately iodized salt was significantly higher in high- than in low-SES households in Bangladesh (58.8% compared with 39.7%, respectively), Ghana (36.2% compared with 21.5%, respectively), India (80.6% compared with 70.5%, respectively), Indonesia (59.9% compared with 45.6%, respectively), the Philippines (39.4% compared with 17.3%, respectively), Senegal (50.7% compared with 27.6%, respectively) and Tanzania (80.9% compared with 51.3%, respectively). Conclusions: Uganda has achieved USI. In other countries, access to iodized salt is inequitable. Quality control and regulatory enforcement of salt iodization remain challenging. Notable progress toward USI has been made in Ethiopia and India. Assessing progress toward USI only through household salt does not account for potentially iodized salt consumed through processed foods.
Effect of a road safety training program on drivers' comparative optimism.
Perrissol, Stéphane; Smeding, Annique; Laumond, Francis; Le Floch, Valérie
2011-01-01
Reducing comparative optimism regarding risk perceptions in traffic accidents has been proven to be particularly difficult (Delhomme, 2000). This is unfortunate because comparative optimism is assumed to impede preventive action. The present study tested whether a road safety training course could reduce drivers' comparative optimism in high control situations. Results show that the training course efficiently reduced comparative optimism in high control, but not in low control situations. Mechanisms underlying this finding and implications for the design of road safety training courses are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.
Evaluating Equating Accuracy and Assumptions for Groups that Differ in Performance
ERIC Educational Resources Information Center
Powers, Sonya; Kolen, Michael J.
2014-01-01
Accurate equating results are essential when comparing examinee scores across exam forms. Previous research indicates that equating results may not be accurate when group differences are large. This study compared the equating results of frequency estimation, chained equipercentile, item response theory (IRT) true-score, and IRT observed-score…
IRT Equating of the MCAT. MCAT Monograph.
ERIC Educational Resources Information Center
Hendrickson, Amy B.; Kolen, Michael J.
This study compared various equating models and procedures for a sample of data from the Medical College Admission Test(MCAT), considering how item response theory (IRT) equating results compare with classical equipercentile results and how the results based on use of various IRT models, observed score versus true score, direct versus linked…
Thermal Conductivities of Some Polymers and Composites
2018-02-01
volume fraction of glass and fabric style. The experimental results are compared to modeled results for Kt in composites. 15. SUBJECT TERMS...entities in a polymer above TG increases, so Cp will increase at TG. For Kt to remain constant, there would have to be a comparable decrease in α due to...scanning calorimetry (DSC) method, and have error bars as large as the claimed effect. Their Kt values for their carbon fiber samples are comparable to
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
47 CFR 90.165 - Procedures for mutually exclusive applications.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., the Commission may use competitive bidding, random selection, or comparative hearings, depending on... exclusive applications in a renewal filing group are designated for comparative consideration in a hearing... applications in the filing group for comparative consideration in a hearing. In this event, the result of the...
Real-time segmentation of burst suppression patterns in critical care EEG monitoring
Westover, M. Brandon; Shafi, Mouhsin M.; Ching, ShiNung; Chemali, Jessica J.; Purdon, Patrick L.; Cash, Sydney S.; Brown, Emery N.
2014-01-01
Objective Develop a real-time algorithm to automatically discriminate suppressions from non-suppressions (bursts) in electroencephalograms of critically ill adult patients. Methods A real-time method for segmenting adult ICU EEG data into bursts and suppressions is presented based on thresholding local voltage variance. Results are validated against manual segmentations by two experienced human electroencephalographers. We compare inter-rater agreement between manual EEG segmentations by experts with inter-rater agreement between human vs automatic segmentations, and investigate the robustness of segmentation quality to variations in algorithm parameter settings. We further compare the results of using these segmentations as input for calculating the burst suppression probability (BSP), a continuous measure of depth-of-suppression. Results Automated segmentation was comparable to manual segmentation, i.e. algorithm-vs-human agreement was comparable to human-vs-human agreement, as judged by comparing raw EEG segmentations or the derived BSP signals. Results were robust to modest variations in algorithm parameter settings. Conclusions Our automated method satisfactorily segments burst suppression data across a wide range adult ICU EEG patterns. Performance is comparable to or exceeds that of manual segmentation by human electroencephalographers. Significance Automated segmentation of burst suppression EEG patterns is an essential component of quantitative brain activity monitoring in critically ill and anesthetized adults. The segmentations produced by our algorithm provide a basis for accurate tracking of suppression depth. PMID:23891828
Lindbaek, Morten; Høiby, Ernst Arne; Lermark, Gro; Steinsholt, Inger Marie; Hjortdahl, Per
2004-12-01
To compare an antigen detection test (GAS antigen test) with the results from combinations of two various bacteriological test media in general practice patients with sore throat. Furthermore to assess the diagnostic properties of the chosen GAS antigen test and to compare semi-quantitative results of this test with the bacterial load found in the throat culture. Two Norwegian general practices in Stokke and Kongsberg communities. 306 patients with sore throat lasting less than 7 days; 244 were adults, 62 were children under 10 years old, mean age 23.9 years (SD 15.0), 40% were men. Results from GAS antigen test, and distribution of bacteriological findings in throat cultures, compared with the results of our GAS antigen test; semi-quantitative results of the GAS antigen test compared with the bacterial load by culture. In the primary culture 110 patients harboured group A streptococci (GAS) infection, while the second culture identified another 17, giving a total of 127 patients. Some 33 patients harboured large-colony groups C and G. The GAS antigen test used had a sensitivity of 97% and specificity of 95% regarding GAS when compared with the two cultures. We found a significant correlation between the bacterial loads by culture and the semi-quantitative results of the GAS antigen test. By using a second, different set of bacteriological media, we identified an additional 17 patients with GAS infections. This raises the question of validity of frequently used reference standards in studies related to streptococcal infections. Compared with the combined results of the two throat cultures, the GAS antigen test used showed high sensitivity and specificity. Semi-quantitative evaluations of the rapid immunological test may also be of clinical value.
Stewart, Elizabeth A; Lytle, Barbara L; Thomas, Laine; Wegienka, Ganesa R; Jacoby, Vanessa; Diamond, Michael P; Nicholson, Wanda K; Anchan, Raymond M; Venable, Sateria; Wallace, Kedra; Marsh, Erica E; Maxwell, George L; Borah, Bijan J; Catherino, William H; Myers, Evan R
2018-05-08
To design and establish a uterine fibroid (UF) registry based in the United States (US) to provide comparative effectiveness data regarding UF treatment. We report here the design and initial recruitment for the Comparing Options for Management: Patient-centered Results for Uterine Fibroids (COMPARE-UF) registry (Clinicaltrials.gov, NCT02260752), funded by the Agency for Healthcare Research and Quality (AHRQ) in collaboration with the-Patient-Centered Outcomes Research Institute (PCORI). COMPARE-UF is designed to help answer critical questions about treatment options for women with symptomatic UF. Women undergoing a procedure for UF (hysterectomy, myomectomy [abdominal, hysteroscopic, vaginal and laparoscopic/robotic], endometrial ablation, radiofrequency fibroid ablation, uterine artery embolization, magnetic resonance guided focused ultrasound or progestin-releasing intrauterine device insertion) at one of the COMPARE-UF sites are invited to participate in a prospective registry with three years follow-up for post-procedural outcomes. Enrolled participants provide annual follow-up through an online portal or through traditional phone contact. A central data abstraction center provides information obtained from imaging, operative or procedural notes and pathology reports. Women with uterine fibroids and other stakeholders are a key part of the COMPARE-UF registry and participate at all points from study design to dissemination of results. We built a network of nine clinical sites across the US with expertise in the care of women with UF to capture geographic, racial, ethnic and procedural diversity. Of the initial 2031 women enrolled in COMPARE-UF, 42% are self-identified as Black or African-American and 40% are age 40 years or younger with 16% of participants under age 35. Women undergoing myomectomy comprise the largest treatment group at 46% of all procedures with laparoscopic or robotic myomectomy comprising the largest subset of myomectomies at 19% of all procedures. Hysterectomy is the second most common treatment within the registry at 38%. In response to priorities identified by our patient stakeholders, the initial aims within COMPARE-UF will address how different procedures used to treat UF compare in terms of long-lasting symptom relief, potential for recurrence, medical complications, improvement in quality of life and sexual function, age at menopause, and fertility and pregnancy outcomes. COMPARE-UF will generate evidence on the comparative effectiveness of different procedural options for UF, in order to help patients and their caregivers make informed decisions that best meet an individual patient's short- and long-term preferences. Building upon this infrastructure, the COMPARE-UF team of investigators and stakeholders, including patients, collaborate to identify future priorities for expanding the registry, such assessing the efficacy of medical therapies for UF. COMPARE-UF results will be disseminated directly to patients, providers, and other stakeholders using traditional academic pathways, as well as innovative methods, including a variety of social media platforms. Given demographic differences among women undergoing different UF treatments, assessing comparative effectiveness for this disease through clinical trials will remain difficult. Therefore, this registry provides optimized evidence to help patients and their providers better understand the pros and cons of different treatment options so that they can make more informed decisions. Copyright © 2018. Published by Elsevier Inc.
Investigation of the flight mechanics simulation of a hovering helicopter
NASA Technical Reports Server (NTRS)
Chaimovich, M.; Rosen, A.; Rand, O.; Mansur, M. H.; Tischler, M. B.
1992-01-01
The flight mechanics simulation of a hovering helicopter is investigated by comparing the results of two different numerical models with flight test data for a hovering AH-64 Apache. The two models are the U.S. Army BEMAP and the Technion model. These nonlinear models are linearized by applying a numerical linearization procedure. The results of the linear models are compared with identification results in terms of eigenvalues, stability and control derivatives, and frequency responses. Detailed time histories of the responses of the complete nonlinear models, as a result of various pilots' inputs, are compared with flight test results. In addition the sensitivity of the models to various effects are also investigated. The results are discussed and problematic aspects of the simulation are identified.
12 CFR 630.20 - Contents of the annual report to investors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...
12 CFR 630.20 - Contents of the annual report to investors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...
12 CFR 630.20 - Contents of the annual report to investors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...
12 CFR 630.20 - Contents of the annual report to investors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...
12 CFR 630.20 - Contents of the annual report to investors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...
Evaluation of Database Coverage: A Comparison of Two Methodologies.
ERIC Educational Resources Information Center
Tenopir, Carol
1982-01-01
Describes experiment which compared two techniques used for evaluating and comparing database coverage of a subject area, e.g., "bibliography" and "subject profile." Differences in time, cost, and results achieved are compared by applying techniques to field of volcanology using two databases, Geological Reference File and GeoArchive. Twenty…
Results of the 1980 NACUBO Comparative Performance Study and Investment Questionnaire.
ERIC Educational Resources Information Center
Dresner, Bruce M.
The purpose of the annual National Association of College and University Business Officers' (NACUBO) Comparative Performance Study is to aid administrators in evaluating the performance of their investment pools. The 1980 study contains two parts: (1) comparative performance information and related investment performance statistics; and (2) other…
Comparative tests of bench equipment for fuel control system testing of gas-turbine engine
NASA Astrophysics Data System (ADS)
Shendaleva, E. V.
2018-04-01
The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.
A comparative study between shielded and open coplanar waveguide discontinuities
NASA Technical Reports Server (NTRS)
Dib, Nihad I.; Harokopus, W. P., Jr.; Ponchak, G. E.; Katehi, L. P. B.
1993-01-01
A comparative study between open and shielded coplanar waveguide (CPW) discontinuities is presented. The space domain integral equation method is used to characterize several discontinuities such as the open-end CPW and CPW series stubs. Two different geometries of CPW series stubs (straight and bent stubs) are compared with respect to resonant frequency and radiation loss. In addition, the encountered radiation loss due to different CPW shunt stubs is evaluated experimentally. The notion of forced radiation simulation is presented, and the results of such a simulation are compared to the actual radiation loss obtained rigorously. It is shown that such a simulation cannot give reliable results concerning radiation loss from printed circuits.
Comparing digital data processing techniques for surface mine and reclamation monitoring
NASA Technical Reports Server (NTRS)
Witt, R. G.; Bly, B. G.; Campbell, W. J.; Bloemer, H. H. L.; Brumfield, J. O.
1982-01-01
The results of three techniques used for processing Landsat digital data are compared for their utility in delineating areas of surface mining and subsequent reclamation. An unsupervised clustering algorithm (ISOCLS), a maximum-likelihood classifier (CLASFY), and a hybrid approach utilizing canonical analysis (ISOCLS/KLTRANS/ISOCLS) were compared by means of a detailed accuracy assessment with aerial photography at NASA's Goddard Space Flight Center. Results show that the hybrid approach was superior to the traditional techniques in distinguishing strip mined and reclaimed areas.
Glaucoma diagnosis by mapping macula with Fourier domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Tan, Ou; Lu, Ake; Chopra, Vik; Varma, Rohit; Hiroshi, Ishikawa; Schuman, Joel; Huang, David
2008-03-01
A new image segmentation method was developed to detect macular retinal sub-layers boundary on newly-developed Fourier-Domain Optical Coherence Tomography (FD-OCT) with macular grid scan pattern. The segmentation results were used to create thickness map of macular ganglion cell complex (GCC), which contains the ganglion cell dendrites, cell bodies and axons. Overall average and several pattern analysis parameters were defined on the GCC thickness map and compared for the diagnosis of glaucoma. Intraclass correlation (ICC) is used to compare the reproducibility of the parameters. Area under receiving operative characteristic curve (AROC) was calculated to compare the diagnostic power. The result is also compared to the output of clinical time-domain OCT (TD-OCT). We found that GCC based parameters had good repeatability and comparable diagnostic power with circumpapillary nerve fiber layer (cpNFL) thickness. Parameters based on pattern analysis can increase the diagnostic power of GCC macular mapping.
Beard, Brian B; Kainz, Wolfgang
2004-10-13
We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head.
Beard, Brian B; Kainz, Wolfgang
2004-01-01
We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head. PMID:15482601
Douglas, Steven; Dixon, Barnali; Griffin, Dale W.
2018-01-01
With continued population growth and increasing use of fresh groundwater resources, protection of this valuable resource is critical. A cost effective means to assess risk of groundwater contamination potential will provide a useful tool to protect these resources. Integrating geospatial methods offers a means to quantify the risk of contaminant potential in cost effective and spatially explicit ways. This research was designed to compare the ability of intrinsic (DRASTIC) and specific (Attenuation Factor; AF) vulnerability models to indicate groundwater vulnerability areas by comparing model results to the presence of pesticides from groundwater sample datasets. A logistic regression was used to assess the relationship between the environmental variables and the presence or absence of pesticides within regions of varying vulnerability. According to the DRASTIC model, more than 20% of the study area is very highly vulnerable. Approximately 30% is very highly vulnerable according to the AF model. When groundwater concentrations of individual pesticides were compared to model predictions, the results were mixed. Model predictability improved when concentrations of the group of similar pesticides were compared to model results. Compared to the DRASTIC model, the AF model more accurately predicts the distribution of the number of contaminated wells within each vulnerability class.
Comparative transcriptomics of early dipteran development
2013-01-01
Background Modern sequencing technologies have massively increased the amount of data available for comparative genomics. Whole-transcriptome shotgun sequencing (RNA-seq) provides a powerful basis for comparative studies. In particular, this approach holds great promise for emerging model species in fields such as evolutionary developmental biology (evo-devo). Results We have sequenced early embryonic transcriptomes of two non-drosophilid dipteran species: the moth midge Clogmia albipunctata, and the scuttle fly Megaselia abdita. Our analysis includes a third, published, transcriptome for the hoverfly Episyrphus balteatus. These emerging models for comparative developmental studies close an important phylogenetic gap between Drosophila melanogaster and other insect model systems. In this paper, we provide a comparative analysis of early embryonic transcriptomes across species, and use our data for a phylogenomic re-evaluation of dipteran phylogenetic relationships. Conclusions We show how comparative transcriptomics can be used to create useful resources for evo-devo, and to investigate phylogenetic relationships. Our results demonstrate that de novo assembly of short (Illumina) reads yields high-quality, high-coverage transcriptomic data sets. We use these data to investigate deep dipteran phylogenetic relationships. Our results, based on a concatenation of 160 orthologous genes, provide support for the traditional view of Clogmia being the sister group of Brachycera (Megaselia, Episyrphus, Drosophila), rather than that of Culicomorpha (which includes mosquitoes and blackflies). PMID:23432914
Moreira, Sílvia A; Fernandes, Pedro A R; Duarte, Ricardo; Santos, Diana I; Fidalgo, Liliana G; Santos, Mauro D; Queirós, Rui P; Delgadillo, Ivonne; Saraiva, Jorge A
2015-11-01
Hyperbaric storage (HS), storage under pressure at 25°C and 30°C, of a ready-to-eat (RTE) soup was studied and compared with refrigeration. Soup was stored at different time (4 and 8 h), temperature (4°C, 25°C, and 30°C), and pressure (0.1, 100, and 150 MPa) conditions, to compare microbial loads and physicochemical parameters. HS resulted in similar (microbial growth inhibition) to better (microbial inactivation) results compared to refrigeration, leading to equal and lower microbial loads, respectively, at the end of storage. Lower/higher pressure (100 vs. 150 MPa) and shorter/longer storage times (4 vs. 8 h) resulted in more pronounced microbial growth inhibition/microbial inactivation. Aerobic mesophiles showed less susceptibility to HS, compared to Enterobacteriaceae and yeast and molds. HS maintained generally the physicochemical parameters at values similar to refrigeration. Thus, HS with no need for temperature control throughout storage and so basically energetically costless, is a potential alternative to refrigeration.
Chiereghin, Angela; Pavia, Claudia; Gabrielli, Liliana; Piccirilli, Giulia; Squarzoni, Diego; Turello, Gabriele; Gibertoni, Dino; Simonazzi, Giuliana; Capretti, Maria Grazia; Lanari, Marcello; Lazzarotto, Tiziana
2017-10-01
Clinical evaluation of the Elecsys ® CMV IgM, IgG, IgG Avidity and COBAS AmpliPrep/COBAS TaqMan CMV (COBAS CMV) assays (Roche Diagnostics AG) in the diagnosis and prognosis of congenital CMV infection was performed. In this study, 150 preselected clinical samples (50 primary infection sera, 50 amniotic fluid [AF] and 50 newborn urine) were processed using Roche serological/molecular CMV-specific tests. Results were compared with those obtained by routine assays (comparator assays). The Elecsys ® CMV IgM and IgG assays showed a perfect agreement (100%) with the comparator assays. Using the combination of the Elecsys ® CMV IgM and IgG Avidity assays results, a primary infection was identified in 100% of cases. Inappropriate avidity CMV IgG values in two samples with very low IgG values (<6 AU/mL) were observed. COBAS CMV assay showed an agreement equal to 98% and 100% with comparator assays by processing AF and urine samples, respectively. Among AF with quantitative results, Lin's concordance correlation was 0.933 and comparator-COBAS CMV assays gave CMV-DNA loads differing by <0.5 log 10 DNA. Finally, higher CMV-DNA levels in AF samples were associated with a symptomatic outcome (p=0.003). The Roche CMV-specific assays compared well with the comparator assays, thus providing to be suitable for clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.
PRP for Degenerative Cartilage Disease: A Systematic Review of Clinical Studies
Laver, Lior; Marom, Niv; Dnyanesh, Lad; Mei-Dan, Omer; Espregueira-Mendes, João; Gobbi, Alberto
2016-01-01
Objective: To explore the utilization of platelet-rich plasma (PRP) for degenerative cartilage processes and evaluate whether there is sufficient evidence to better define its potential effects. Design: Systematic literature reviews were conducted in PubMed/MEDLINE and Cochrane electronic databases till May 2015, using the keywords “platelet-rich plasma OR PRP OR autologous conditioned plasma OR ACP AND cartilage OR chondrocyte OR chondrogenesis OR osteoarthritis (OA) OR arthritis.” Results: The final result yielded 29 articles. Twenty-six studies examined PRP administration for knee OA and 3 involved PRP administration for hip OA. The results included 9 prospective randomized controlled trials (RCTs) (8 knee and 1 hip), 4 prospective comparative studies, 14 case series, and 2 retrospective comparative studies. Hyaluronic acid (HA) was used as a control in 11 studies (7 RCTs, 2 prospective comparative studies, and 2 retrospective cohort). Overall, all RCTs reported on improved symptoms compared to baseline scores. Only 2 RCTs—one for knee and one for hip—did not report significant superiority of PRP compared to the control group (HA). Nine out of 11 HA controlled studies showed significant better results in the PRP groups. A trend toward better results for PRP injections in patients with early knee OA and young age was observed; however, lack of uniformity was evident in terms of indications, inclusion criteria, and pathology definitions in the different studies. Conclusion: Current clinical evidence supports the benefit in PRP treatment for knee and hip OA, proven to temporarily relieve pain and improve function of the involved joint with superior results compared with several alternative treatments. Further research to establish the optimal preparation protocol and characteristics of PRP injections for OA is needed. PMID:28317389
Fano, Valeria; D'Ovidio, Mariangela; del Zio, Katiuscia; Renzi, Davide; Tariciotti, Daniela; Agabiti, Nera; Argenti, Lucia; Cattaruzza, Maria Sofia; Fortino, Antonio
2012-01-01
To analyse the results of the regional comparative evaluation of the outcome "thirty days mortality after admission for reacutized Chronic obstructive pulmonary disease (COPD)" before and after a reabstract study. Reabstract study of clinical records included in the regional comparative evaluation. 232 clinical records retrieved from Grassi Hospital archives (years 2006-2007) and reviewed by two physicians and one nurse specifically trained. Models performed before and after reabstract study for comparative evaluation of the outcome were compared. Blind coding of diagnosis and interventions/procedures was completed according to a standard grid consistent with regional guidelines for Hospital Discharge Record coding. Other information was registered, if present on discharge record: smoking habit, number of reacutizations occurred within previous year, use of oxigen and/or other therapies, pneumological visit at discharge. The majority (94%) of reviewed cases were confirmed as being cases of COPD. A total of 168 cases (72%) have been identified as reacutized COPD coherent with enrolment criteria of regional program, 49 (21%) have been identified as COPD and only 15 cases (6%) resulted not affected by COPD. Results of the regional comparative model were substantially unchanged for Grassi hospital (RR =23 vs RR =24). Accurateness of clinical documentation resulted inadequate especially regarding information at discharge (50% missing information on smoking habit, 83% on previous year reacutizations, 22% on follow-up organization after discharge). This study contributes to the debate on the role of administrative data on the comparative evaluation of health outcomes. Other relevant issues are to promote the collaboration among different health professionals working in the same hospital, and to increase the awareness of the importance of the quality of health and administrative data.
A 100g Mass Comparator with an Improved Readability and Measuring Environment
NASA Astrophysics Data System (ADS)
Ueki, Masaaki; Sun, Jian-Xin; Ueda, Kazunaga
In order to achieve higher accuracy of the mass standard in the mass range equal to or less than 100g, it is necessary for a mass comparator in the range to have a relative sensitivity of the order of 1×10-9. For this purpose, a 111g capacity fully-automatic mass comparator has been renovated so that its readability is improved from 1 to 0.1µg. The mass comparator is also installed in an air-tight chamber originally developed by the NMIJ, so that it can be kept in stable environment, especially in the air of constant density. With these renovations, standard deviation of the mass comparisons is reduced and uncertainty of the air buoyancy corrections is lessened. This paper reports the features of the improved 100g mass comparator, the empirical method to evaluate its performance and the obtained results. As a result, the standard deviations of the mass difference measurements have been greatly improved to 0.22µg in the average with the chamber closed, compared with 0.97µg with the one open. The linearity of the comparator has been also verified by the mass difference measurements of weights at the six masses of 10, 20, 30, 50, 70 and 100g, and it confirms that the non-linearity errors of the comparator are within 0.28µg, showing good measuring performance.
Maeda, Jared Lane K; Lee, Karen M; Horberg, Michael
2014-01-01
Because of rising health care costs, wide variations in quality, and increased patient complexity, the US health care system is undergoing rapid changes that include payment reform and movement toward integrated delivery systems. Well-established integrated delivery systems, such as Kaiser Permanente (KP), should work to identify the specific system-level factors that result in superior patient outcomes in response to policymakers' concerns. Comparative health systems research can provide insights into which particular aspects of the integrated delivery system result in improved care delivery. To provide a baseline understanding of comparative health systems research related to integrated delivery systems and KP. Systematic literature review. We conducted a literature search on PubMed and the KP Publications Library. Studies that compared KP as a system or organization with other health care systems or across KP facilities internally were included. The literature search identified 1605 articles, of which 65 met the study inclusion criteria and were examined by 3 reviewers. Most comparative health systems studies focused on intra-KP comparisons (n = 42). Fewer studies compared KP with other US (n = 15) or international (n = 12) health care systems. Several themes emerged from the literature as possible factors that may contribute to improved care delivery in integrated delivery systems. Of all studies published by or about KP, only a small proportion of articles (4%) was identified as being comparative health systems research. Additional empirical studies that compare the specific factors of the integrated delivery system model with other systems of care are needed to better understand the "system-level" factors that result in improved and/or diminished care delivery.
Postbuckling and Growth of Delaminations in Composite Plates Subjected to Axial Compression
NASA Technical Reports Server (NTRS)
Reeder, James R.; Chunchu, Prasad B.; Song, Kyongchan; Ambur, Damodar R.
2002-01-01
The postbuckling response and growth of circular delaminations in flat and curved plates are investigated as part of a study to identify the criticality of delamination locations through the laminate thickness. The experimental results from tests on delaminated plates are compared with finite element analysis results generated using shell models. The analytical prediction of delamination growth is obtained by assessing the strain energy release rate results from the finite element model and comparing them to a mixed-mode fracture toughness failure criterion. The analytical results for onset of delamination growth compare well with experimental results generated using a 3-dimensional displacement visualization system. The record of delamination progression measured in this study has resulted in a fully 3-dimensional test case with which progressive failure models can be validated.
ERIC Educational Resources Information Center
Glover, Robert H.; Mills, Michael R.
A research design, decision support system, and results of a comparative analysis of enrollment and financial strength (of private institutions granting masters and doctoral degrees) are presented. Cluster analysis, discriminant analysis, multiple regression, and an interactive decision support system are used to compare the enrollment and…
Comparative Historical Approaches in Religious Education Research--Methodological Perspectives
ERIC Educational Resources Information Center
Schröder, Bernd
2016-01-01
This article summarises the state of comparative historical research in the field of religious education. After describing a range of purposes to be fulfilled by comparative studies, it categorises a number of studies written in either English, French or German according to their methodological approach and subject focus. As a result, a…
Comparative dynamics in a health investment model.
Eisenring, C
1999-10-01
The method of comparative dynamics fully exploits the inter-temporal structure of optimal control models. I derive comparative dynamic results in a simplified demand for health model. The effect of a change in the depreciation rate on the optimal paths for health capital and investment in health is studied by use of a phase diagram.
ERIC Educational Resources Information Center
Biswas, Sheela
1990-01-01
Conducted retrospective case note study comparing various characteristics of self-poisoning between White (N=34) and Asian adolescents (N=38). Results showed "Culture Conflict" was implicated in slightly more Asian female self-poisonings as compared to males, Asian females used "non ingestants" significantly more than White…
Grading A-Level Double Subject Mathematicians and the Implications for Selection.
ERIC Educational Resources Information Center
Newbould, Charles A.
1981-01-01
Test data were used to compare the grading of two forms of double mathematics: pure and applied math, and regular and advanced math. Results confirm expectations that in the former system, the grading is comparable, and in the latter, it is not necessarily comparable. Implications for student admission are discussed. (MSE)
12 CFR 620.5 - Contents of the annual report to shareholders.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Selected financial data. Furnish in comparative columnar form for each of the last 5 fiscal years the... losses to provide for such risk. (2) Results of operations. (i) Describe, on a comparative basis, changes...) Describe, on a comparative basis, the major components of operating expense, indicating the reasons for...
12 CFR 620.5 - Contents of the annual report to shareholders.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Selected financial data. Furnish in comparative columnar form for each of the last 5 fiscal years the... losses to provide for such risk. (2) Results of operations. (i) Describe, on a comparative basis, changes...) Describe, on a comparative basis, the major components of operating expense, indicating the reasons for...
12 CFR 620.5 - Contents of the annual report to shareholders.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Selected financial data. Furnish in comparative columnar form for each of the last 5 fiscal years the... losses to provide for such risk. (2) Results of operations. (i) Describe, on a comparative basis, changes...) Describe, on a comparative basis, the major components of operating expense, indicating the reasons for...
Comparative study on direct burning of oil shale and coal
NASA Astrophysics Data System (ADS)
Hammad, Ahmad; Al Asfar, Jamil
2017-07-01
A comparative study of the direct burning processes of oil shale and coal in a circulating fluidized bed (CFB) was done in this study using ANSYS Fluent software to solve numerically the governing equations of continuity, momentum, energy and mass diffusion using finite volume method. The model was built based on an existing experimental combustion burner unit. The model was validated by comparing the theoretical results of oil shale with proved experimental results from the combustion unit. It was found that the temperature contours of the combustion process showed that the adiabatic flame temperature was 1080 K for oil shale compared with 2260 K for coal, while the obtained experimental results of temperatures at various locations of burner during the direct burning of oil shale showed that the maximum temperature reached 962 K for oil shale. These results were used in economic and environmental analysis which show that oil shale may be used as alternative fuel for coal in cement industry in Jordan.
Desai, Nandini J.; Gupta, B. D.; Patel, Pratik Narendrabhai
2014-01-01
Introduction: Obtaining images of slides viewed by a microscope can be invaluable for both diagnosis and teaching.They can be transferred among technologically-advanced hospitals for further consultation and evaluation. But a standard microscopic photography camera unit (MPCU)(MIPS-Microscopic Image projection System) is costly and not available in resource poor settings. The aim of our endeavour was to find a comparable and cheaper alternative method for photomicrography. Materials and Methods: We used a NIKON Coolpix S6150 camera (box type digital camera) with Olympus CH20i microscope and a fluorescent microscope for the purpose of this study. Results: We got comparable results for capturing images of light microscopy, but the results were not as satisfactory for fluorescent microscopy. Conclusion: A box type digital camera is a comparable, less expensive and convenient alternative to microscopic photography camera unit. PMID:25478350
Zabetakis, Kara M; Niño de Guzmán, Gabriela T; Torrents, Alba; Yarwood, Stephanie
2015-01-01
The microbiological impact of zero-valent iron used in the remediation of groundwater was investigated by exposing a trichloroethylene-degrading anaerobic microbial community to two types of iron nanoparticles. Changes in total bacterial and archaeal population numbers were analyzed using qPCR and were compared to results from a blank and negative control to assess for microbial toxicity. Additionally, the results were compared to those of samples exposed to silver nanoparticles and iron filings in an attempt to discern the source of toxicity. Statistical analysis revealed that the three different iron treatments were equally toxic to the total bacteria and archaea populations, as compared with the controls. Conversely, the silver nanoparticles had a limited statistical impact when compared to the controls and increased the microbial populations in some instances. Therefore, the findings suggest that zero-valent iron toxicity does not result from a unique nanoparticle-based effect.
A comparative study of electrochemical machining process parameters by using GA and Taguchi method
NASA Astrophysics Data System (ADS)
Soni, S. K.; Thomas, B.
2017-11-01
In electrochemical machining quality of machined surface strongly depend on the selection of optimal parameter settings. This work deals with the application of Taguchi method and genetic algorithm using MATLAB to maximize the metal removal rate and minimize the surface roughness and overcut. In this paper a comparative study is presented for drilling of LM6 AL/B4C composites by comparing the significant impact of numerous machining process parameters such as, electrolyte concentration (g/l),machining voltage (v),frequency (hz) on the response parameters (surface roughness, material removal rate and over cut). Taguchi L27 orthogonal array was chosen in Minitab 17 software, for the investigation of experimental results and also multiobjective optimization done by genetic algorithm is employed by using MATLAB. After obtaining optimized results from Taguchi method and genetic algorithm, a comparative results are presented.
Autograft versus Allograft for Cervical Spinal Fusion
Brodke, Darrel S.; Youssef, Jim A.; Meisel, Hans-Jörg; Dettori, Joseph R.; Park, Jong-Beom; Yoon, S. Tim; Wang, Jeffrey C.
2017-01-01
Study Design Systematic review. Objective To compare the effectiveness and safety between iliac crest bone graft (ICBG), non-ICBG autologous bone, and allograft in cervical spine fusion. To avoid problems at the donor site, various allograft materials have been used as a substitute for autograft. However, there are still questions as to the comparative effectiveness and safety of cadaver allograft compared with autologous ICBG. Methods A systematic search of multiple major medical reference databases was conducted to identify studies evaluating spinal fusion in patients with cervical degenerative disk disease using ICBG compared with non-ICBG autograft or allograft or non-ICBG autograft compared with allograft in the cervical spine. Radiographic fusion, patient-reported outcomes, and functional outcomes were the primary outcomes of interest. Adverse events were evaluated for safety. Results The search identified 13 comparative studies that met our inclusion criteria: 2 prospective cohort studies and 11 retrospective cohort studies. Twelve cohort studies compared allograft with ICBG autograft during anterior cervical fusion and demonstrated with a low evidence level of support that there are no differences in fusion percentages, pain scores, or functional results. There was insufficient evidence comparing patients receiving allograft with non-ICBG autograft for fusion, pain, revision, and functional and safety outcomes. No publications directly comparing non-ICBG autograft with ICBG were found. Conclusion Although the available literature suggests ICBG and allograft may have similar effectiveness in terms of fusion rates, pain scores, and functional outcomes following anterior cervical fusion, there are too many limitations in the available literature to draw any significant conclusions. No individual study provided greater than class III evidence, and when evaluating the overall body of literature, no conclusion had better than low evidence support. A prospective randomized trial with adequate sample size to compare fusion rates, efficacy measures, costs, and safety is warranted. PMID:28451511
Information Uncertainty to Compare Qualitative Reasoning Security Risk Assessment Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chavez, Gregory M; Key, Brian P; Zerkle, David K
2009-01-01
The security risk associated with malevolent acts such as those of terrorism are often void of the historical data required for a traditional PRA. Most information available to conduct security risk assessments for these malevolent acts is obtained from subject matter experts as subjective judgements. Qualitative reasoning approaches such as approximate reasoning and evidential reasoning are useful for modeling the predicted risk from information provided by subject matter experts. Absent from these approaches is a consistent means to compare the security risk assessment results. Associated with each predicted risk reasoning result is a quantifiable amount of information uncertainty which canmore » be measured and used to compare the results. This paper explores using entropy measures to quantify the information uncertainty associated with conflict and non-specificity in the predicted reasoning results. The measured quantities of conflict and non-specificity can ultimately be used to compare qualitative reasoning results which are important in triage studies and ultimately resource allocation. Straight forward extensions of previous entropy measures are presented here to quantify the non-specificity and conflict associated with security risk assessment results obtained from qualitative reasoning models.« less
Quantitative evaluation of the CEEM soil sampling intercomparison.
Wagner, G; Lischer, P; Theocharopoulos, S; Muntau, H; Desaules, A; Quevauviller, P
2001-01-08
The aim of the CEEM soil project was to compare and to test the soil sampling and sample preparation guidelines used in the member states of the European Union and Switzerland for investigations of background and large-scale contamination of soils, soil monitoring and environmental risk assessments. The results of the comparative evaluation of the sampling guidelines demonstrated that, in soil contamination studies carried out with different sampling strategies and methods, comparable results can hardly be expected. Therefore, a reference database (RDB) was established by the organisers, which acted as a basis for the quantitative comparison of the participants' results. The detected deviations were related to the methodological details of the individual strategies. The comparative evaluation concept consisted of three steps: The first step was a comparison of the participants' samples (which were both centrally and individually analysed) between each other, as well as with the reference data base (RDB) and some given soil quality standards on the level of concentrations present. The comparison was made using the example of the metals cadmium, copper, lead and zinc. As a second step, the absolute and relative deviations between the reference database and the participants' results (both centrally analysed under repeatability conditions) were calculated. The comparability of the samples with the RDB was categorised on four levels. Methods of exploratory statistical analysis were applied to estimate the differential method bias among the participants. The levels of error caused by sampling and sample preparation were compared with those caused by the analytical procedures. As a third step, the methodological profiles of the participants were compiled to concisely describe the different procedures used. They were related to the results to find out the main factors leading to their incomparability. The outcome of this evaluation process was a list of strategies and methods, which are problematic with respect to comparability, and should be standardised and/or specified in order to arrive at representative and comparable results in soil contamination studies throughout Europe. Pre-normative recommendations for harmonising European soil sampling guidelines and standard operating procedures have been outlined in Wagner G, Desules A, Muntau H, Theocharopoulos S. Comparative Evaluation of European Methods for Sampling and Sample Preparation of Soils for Inorganic Analysis (CEEM Soil). Final Report of the Contract SMT4-CT96-2085, Sci Total Environ 2001;264:181-186. Wagner G, Desaules A, Munatu H. Theocharopolous S, Quevauvaller Ph. Suggestions for harmonising sampling and sample pre-treatment procedures and improving quality assurance in pre-analytical steps of soil contamination studies. Paper 1.7 Sci Total Environ 2001b;264:103-118.
Kreaden, Usha S.; Gabbert, Jessica; Thomas, Raju
2014-01-01
Abstract Introduction: The primary aims of this study were to assess the learning curve effect of robot-assisted radical prostatectomy (RARP) in a large administrative database consisting of multiple U.S. hospitals and surgeons, and to compare the results of RARP with open radical prostatectomy (ORP) from the same settings. Materials and Methods: The patient population of study was from the Premier Perspective Database (Premier, Inc., Charlotte, NC) and consisted of 71,312 radical prostatectomies performed at more than 300 U.S. hospitals by up to 3739 surgeons by open or robotic techniques from 2004 to 2010. The key endpoints were surgery time, inpatient length of stay, and overall complications. We compared open versus robotic, results by year of procedures, results by case volume of specific surgeons, and results of open surgery in hospitals with and without a robotic system. Results: The mean surgery time was longer for RARP (4.4 hours, standard deviation [SD] 1.7) compared with ORP (3.4 hours, SD 1.5) in the same hospitals (p<0.0001). Inpatient stay was shorter for RARP (2.2 days, SD 1.9) compared with ORP (3.2 days, SD 2.7) in the same hospitals (p<0.0001). The overall complications were less for RARP (10.6%) compared with ORP (15.8%) in the same hospitals, as were transfusion rates. ORP results in hospitals without a robot were not better than ORP with a robot, and pretreatment co-morbidity profiles were similar in all cohorts. Trending of results by year of procedure showed no differences in the three cohorts, but trending of RARP results by surgeon experience showed improvements in surgery time, hospital stay, conversion rates, and complication rates. Conclusions: During the initial 7 years of RARP development, outcomes showed decreased hospital stay, complications, and transfusion rates. Learning curve trends for RARP were evident for these endpoints when grouped by surgeon experience, but not by year of surgery. PMID:24350787
Lenhard, Fabian; Ssegonja, Richard; Andersson, Erik; Feldman, Inna; Mataix-Cols, David; Serlachius, Eva
2017-01-01
Objectives To evaluate the cost-effectiveness of a therapist-guided internet-delivered cognitive behaviour therapy (ICBT) intervention for adolescents with obsessive–compulsive disorder (OCD) compared with untreated patients on a waitlist. Design Single-blinded randomised controlled trial. Setting A research clinic within the regular child and adolescent mental health service in Stockholm, Sweden. Participants Sixty-seven adolescents (12–17 years) with a Diagnostic and Statistical Manual of Mental Disorders Fifth Edition diagnosis of OCD. Interventions Either a 12-week, therapist-guided ICBT intervention or a wait list condition of equal duration. Primary outcome measures Cost data were collected at baseline and after treatment, including healthcare use, supportive resources, prescription drugs, prescription-free drugs, school absence and productivity loss, as well as the cost of ICBT. Health outcomes were defined as treatment responder rate and quality-adjusted life years gain. Bootstrapped mixed model analyses were conducted comparing incremental costs and health outcomes between the groups from the societal and healthcare perspectives. Results Compared with waitlist control, ICBT generated substantial societal cost savings averaging US$−144.98 (95% CI −159.79 to –130.16) per patient. The cost reductions were mainly driven by reduced healthcare use in the ICBT group. From the societal perspective, the probability of ICBT being cost saving compared with waitlist control was approximately 60%. From the healthcare perspective, the cost per additional responder to ICBT compared with waitlist control was approximately US$78. Conclusions The results suggest that therapist-guided ICBT is a cost-effective treatment and results in societal cost savings, compared with patients who do not receive evidence-based treatment. Since, at present, most patients with OCD do not have access to evidence-based treatments, the results have important implications for the increasingly strained national and healthcare budgets. Future studies should compare the cost-effectiveness of ICBT with regular face-to-face CBT. Trial registration number NCT02191631. PMID:28515196
2013-01-01
Objective To compare the long term impact on ovarian reserve between laparoscopic ovarian cystectomy with bipolar electrocoagulation and laparotomic cystectomy with suturing for ovarian endometrotic cyst. Patient and method(s) 121 patients with benign ovarian endometroitic cysts were randomised to either laparoscopic ovarian cystectomy using bipolar electrocoagulation (61 patients) or laparotomic ovarian cystectomy using sutures (60 patients). Serum follicle-stimulating hormone, Antimullerian hormon, Basal antral follicle Count, mean ovarian diameter, and ovarian stromal blood flow velocity were measured at 6, 12 and 18 months after surgery and compared in both groups. Result(s) A statistically significant increase of serum FSH was found in the laproscopic bipolar group at 6-, 12 and 18-month postoperativly compared to open laparotomy suture group. Also, a statistically significant decrease of the mean AMH value occurred in laproscopic bipolar group at 6-, 12 and 18-month follow- up compared to open laparotomy suture group. Basal antral follicle number, mean ovarian diameter and peak systolic velocity were significantly decreased during the 6-, 12,18 -month follow-up in laproscopic bipolar group compared to open laparotomy suture group. Conclusion(s) After laproscopic ovarian cystecomy for endometrioma all pareameter of ovarian reseve are significantly decreased on long term follow up as compared to open laprotomy. PMID:24180348
Smith, Gary D; Serafini, Paulo C; Fioravanti, Joyce; Yadid, Isaac; Coslovsky, Marcio; Hassun, Pericles; Alegretti, José Roberto; Motta, Eduardo L
2010-11-01
To compare cryopreservation of mature human oocytes with slow-rate freezing and vitrification and determine which is most efficient at establishing a pregnancy. Prospective randomized. Academically affiliated, private fertility center. Consenting patients with concerns about embryo cryopreservation and more than nine mature oocytes at retrieval were randomized to slow-rate freezing or vitrification of supernumerary (more than nine) oocytes. Oocytes were frozen or vitrified, and upon request oocytes were thawed or warmed, respectively. Oocyte survival, fertilization, embryo development, and clinical pregnancy. Patient use has resulted in 30 thaws and 48 warmings. Women's age at time of cryopreservation was similar. Oocyte survival was significantly higher following vitrification/warming (81%) compared with freezing/thawing (67%). Fertilization was more successful in oocytes vitrified/warmed compared with frozen/thawed. Fertilized oocytes from vitrification/warming had significantly better cleavage rates (84%) compared with freezing/thawing (71%) and resulted in embryos with significantly better morphology. Although similar numbers of embryos were transferred, embryos resulting from vitrified oocytes had significantly enhanced clinical (38%) pregnancy rates compared with embryos resulting from frozen oocyte (13%). Miscarriage and/or spontaneous abortion rates were similar. Our results suggest that vitrification/warming is currently the most efficient means of oocyte cryopreservation in relation to subsequent success in establishing pregnancy. Copyright © 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Comparing Institution Nitrogen Footprints: Metrics for ...
When multiple institutions with strong sustainability initiatives use a new environmental impact assessment tool, there is an impulse to compare. The first seven institutions to calculate their nitrogen footprints using the nitrogen footprint tool have worked collaboratively to improve calculation methods, share resources, and suggest methods for reducing their footprints. This paper compares the results of those seven results to reveal the common and unique drivers of institution nitrogen footprints. The footprints were compared by scope and sector, and the results were normalized by multiple factors (e.g., population, number of meals served). The comparisons found many consistencies across the footprints, including the large contribution of food. The comparisons identified metrics that could be used to track progress, such as an overall indicator for the nitrogen sustainability of food purchases. The results also found differences in system bounds of the calculations, which are important to standardize when comparing across institutions. The footprints were influenced by factors that are both within and outside of the institutions’ ability to control, such as size, location, population, and campus use. However, these comparisons also point to a pathway forward for standardizing nitrogen footprint tool calculations, identifying metrics that can be used to track progress, and determining a sustainable institution nitrogen footprint. This paper is being submitt
Chen-Ying Hung; Wei-Chen Chen; Po-Tsun Lai; Ching-Heng Lin; Chi-Chun Lee
2017-07-01
Electronic medical claims (EMCs) can be used to accurately predict the occurrence of a variety of diseases, which can contribute to precise medical interventions. While there is a growing interest in the application of machine learning (ML) techniques to address clinical problems, the use of deep-learning in healthcare have just gained attention recently. Deep learning, such as deep neural network (DNN), has achieved impressive results in the areas of speech recognition, computer vision, and natural language processing in recent years. However, deep learning is often difficult to comprehend due to the complexities in its framework. Furthermore, this method has not yet been demonstrated to achieve a better performance comparing to other conventional ML algorithms in disease prediction tasks using EMCs. In this study, we utilize a large population-based EMC database of around 800,000 patients to compare DNN with three other ML approaches for predicting 5-year stroke occurrence. The result shows that DNN and gradient boosting decision tree (GBDT) can result in similarly high prediction accuracies that are better compared to logistic regression (LR) and support vector machine (SVM) approaches. Meanwhile, DNN achieves optimal results by using lesser amounts of patient data when comparing to GBDT method.
Evans, Alistair R.; McHenry, Colin R.
2015-01-01
The reliability of finite element analysis (FEA) in biomechanical investigations depends upon understanding the influence of model assumptions. In producing finite element models, surface mesh resolution is influenced by the resolution of input geometry, and influences the resolution of the ensuing solid mesh used for numerical analysis. Despite a large number of studies incorporating sensitivity studies of the effects of solid mesh resolution there has not yet been any investigation into the effect of surface mesh resolution upon results in a comparative context. Here we use a dataset of crocodile crania to examine the effects of surface resolution on FEA results in a comparative context. Seven high-resolution surface meshes were each down-sampled to varying degrees while keeping the resulting number of solid elements constant. These models were then subjected to bite and shake load cases using finite element analysis. The results show that incremental decreases in surface resolution can result in fluctuations in strain magnitudes, but that it is possible to obtain stable results using lower resolution surface in a comparative FEA study. As surface mesh resolution links input geometry with the resulting solid mesh, the implication of these results is that low resolution input geometry and solid meshes may provide valid results in a comparative context. PMID:26056620
ERIC Educational Resources Information Center
Bartholomew, Scott R.; Nadelson, Louis S.; Goodridge, Wade H.; Reeve, Edward M.
2018-01-01
We investigated the use of adaptive comparative judgment to evaluate the middle school student learning, engagement, and experience with the design process in an open-ended problem assigned in a technology and engineering education course. Our results indicate that the adaptive comparative judgment tool effectively facilitated the grading of the…
A. Morani; D. Nowak; S. Hirabayashi; G. Guidolotti; M. Medori; V. Muzzini; S. Fares; G. Scarascia Mugnozza; C. Calfapietra
2014-01-01
Ozone flux estimates from the i-Tree model were compared with ozone flux measurements using the Eddy Covariance technique in a periurban Mediterranean forest near Rome (Castelporziano). For the first time i-Tree model outputs were compared with field measurements in relation to dry deposition estimates. Results showed generally a...
Creating Tic Suppression: Comparing the Effects of Verbal Instruction to Differential Reinforcement
ERIC Educational Resources Information Center
Woods, Douglas W.; Himle, Michael B.
2004-01-01
The purpose of this study was to compare two methods designed to produce tic reduction in 4 children with Tourette's syndrome. Specifically, a verbal instruction not to engage in tics was compared to a verbal instruction plus differential reinforcement of zero-rate behavior (DRO). Results showed that the DRO-enhanced procedure yielded greater…
Outcomes of Group Care for Youth: A Review of Comparative Studies
ERIC Educational Resources Information Center
Lee, Bethany R.; Bright, Charlotte L.; Svoboda, Deborah V.; Fakunmoju, Sunday; Barth, Richard P.
2011-01-01
Objective: The purpose of this study was to review empirical evidence of the effects of placement in group care compared to other interventions. Method: Two-group empirical studies were identified and effect sizes for all reported outcomes were calculated. Results: Nineteen two-group studies were found that compared group care with family foster…
Patterns of Injury Mortality among Athabascan Indians in Interior Alaska 1977-1987.
ERIC Educational Resources Information Center
Andon, Helen B.
1997-01-01
During 1977-87, almost half of all deaths in rural interior Alaska resulted from accidents, suicide, or homicide. These causes of death were significantly higher among Natives compared to non-Natives or to other Alaska Native populations, among males compared to females, and among adolescents and young adults compared to other age groups. Includes…
ERIC Educational Resources Information Center
Valentine, Jeffrey C.; McHugh, Cathleen M.
2007-01-01
Using meta-analysis, randomized experiments in education that either clearly did or clearly did not experience student attrition were examined for the baseline comparability of groups. Results from 35 studies suggested that after attrition, the observed measures of baseline comparability of groups did not differ more than would be expected given…
Horiuchi, Satoshi; Tsuda, Akira; Kobayashi, Hisanori; Fallon, Elizabeth A; Sakano, Yuji
2017-07-01
This study examined self-efficacy (confidence to exercise), pros (exercise's advantages), and cons (exercise's disadvantages) as variables associated across the transtheoretical model's six stages of change in 403 Japanese college students. A series of logistic regression analyses were conducted. Results showed that higher pros and lower cons were associated with being in contemplation compared to precontemplation. Lower cons were associated with being in preparation compared to contemplation. Higher self-efficacy was associated with being in action compared to preparation as well as being in maintenance compared to action. Lower cons were associated with being in termination compared to maintenance.
Conley, Colleen M; Derby, K Mark; Roberts-Gwinn, Michelle; Weber, Kimberly P; McLaughlin, T E
2004-01-01
This study compared the copy, cover, and compare method to a picture-word matching method for teaching sight word recognition. Participants were 5 kindergarten students with less than preprimer sight word vocabularies who were enrolled in a public school in the Pacific Northwest. A multielement design was used to evaluate the effects of the two interventions. Outcomes suggested that sight words taught using the copy, cover, and compare method resulted in better maintenance of word recognition when compared to the picture-matching intervention. Benefits to students and the practicality of employing the word-level teaching methods are discussed.
Method for revealing biases in precision mass measurements
NASA Astrophysics Data System (ADS)
Vabson, V.; Vendt, R.; Kübarsepp, T.; Noorma, M.
2013-02-01
A practical method for the quantification of systematic errors of large-scale automatic comparators is presented. This method is based on a comparison of the performance of two different comparators. First, the differences of 16 equal partial loads of 1 kg are measured with a high-resolution mass comparator featuring insignificant bias and 1 kg maximum load. At the second stage, a large-scale comparator is tested by using combined loads with known mass differences. Comparing the different results, the biases of any comparator can be easily revealed. These large-scale comparator biases are determined over a 16-month period, and for the 1 kg loads, a typical pattern of biases in the range of ±0.4 mg is observed. The temperature differences recorded inside the comparator concurrently with mass measurements are found to remain within a range of ±30 mK, which obviously has a minor effect on the detected biases. Seasonal variations imply that the biases likely arise mainly due to the functioning of the environmental control at the measurement location.
Meisel, Zachary F; Carr, Brendan G; Conway, Patrick H
2012-09-01
Federal legislation placed comparative effectiveness research and patient-centered outcomes research at the center of current and future national investments in health care research. The role of this research in emergency care has not been well described. This article proposes an agenda for researchers and health care providers to consider comparative effectiveness research and patient-centered outcomes research methods and results to improve the care for patients who seek, use, and require emergency care. This objective will be accomplished by (1) exploring the definitions, frameworks, and nomenclature for comparative effectiveness research and patient-centered outcomes research; (2) describing a conceptual model for comparative effectiveness research in emergency care; (3) identifying specific opportunities and examples of emergency care-related comparative effectiveness research; and (4) categorizing current and planned funding for comparative effectiveness research and patient-centered outcomes research that can include emergency care delivery. Copyright © 2012. Published by Mosby, Inc.
The Distinct Role of Comparative Risk Perceptions in a Breast Cancer Prevention Program
Dillard, Amanda J.; Ubel, Peter A.; Smith, Dylan M.; Zikmund-Fisher, Brian J.; Nair, Vijay; Derry, Holly A.; Zhang, Aijun; Pitsch, Rosemarie K.; Alford, Sharon Hensley; McClure, Jennifer B.; Fagerlin, Angela
2013-01-01
Background Comparative risk perceptions may rival other types of information in terms of effects on health behavior decisions. Purpose We examined associations between comparative risk perceptions, affect, and behavior while controlling for absolute risk perceptions and actual risk. Methods Women at an increased risk of breast cancer participated in a program to learn about tamoxifen which can reduce the risk of breast cancer. Women reported comparative risk perceptions of breast cancer and completed measures of anxiety, knowledge, and tamoxifen-related behavior intentions. Three months later, women reported their behavior. Results Comparative risk perceptions were positively correlated with anxiety, knowledge, intentions, and behavior three months later. After controlling for participants’ actual risk of breast cancer and absolute risk perceptions, comparative risk perceptions predicted anxiety and knowledge, but not intentions or behavior. Conclusions Comparative risk perceptions can affect patient outcomes like anxiety and knowledge independently of absolute risk perceptions and actual risk information. PMID:21698518
Petherick, Emily S; Pickett, Kate E; Cullum, Nicky A
2015-08-01
Primary care databases from the UK have been widely used to produce evidence on the epidemiology and health service usage of a wide range of conditions. To date there have been few evaluations of the comparability of estimates between different sources of these data. To estimate the comparability of two widely used primary care databases, the Health Improvement Network Database (THIN) and the General Practice Research Database (GPRD) using venous leg ulceration as an exemplar condition. Cross prospective cohort comparison. GPRD and the THIN databases using data from 1998 to 2006. A data set was extracted from both databases containing all cases of persons aged 20 years or greater with a database diagnosis of venous leg ulceration recorded in the databases for the period 1998-2006. Annual rates of incidence and prevalence of venous leg ulceration were calculated within each database and standardized to the European standard population and compared using standardized rate ratios. Comparable estimates of venous leg ulcer incidence from the GPRD and THIN databases could be obtained using data from 2000 to 2006 and of prevalence using data from 2001 to 2006. Recent data collected by these two databases are more likely to produce comparable results of the burden venous leg ulceration. These results require confirmation in other disease areas to enable researchers to have confidence in the comparability of findings from these two widely used primary care research resources. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Finding a Comparison Group: Is Online Crowdsourcing a Viable Option?
ERIC Educational Resources Information Center
Azzam, Tarek; Jacobson, Miriam R.
2013-01-01
This article explores the viability of online crowdsourcing for creating matched-comparison groups. This exploratory study compares survey results from a randomized control group to survey results from a matched-comparison group created from Amazon.com's MTurk crowdsourcing service to determine their comparability. Study findings indicate…
DOT National Transportation Integrated Search
2013-10-01
The paper compares the fatigue life of neat and modified PAV-aged binders and mastics and : determines the influence of dust on fatigue life using the Linear Amplitude Sweep (LAS) method. It : will also compare these results with results from the DER...
Real-time segmentation of burst suppression patterns in critical care EEG monitoring.
Brandon Westover, M; Shafi, Mouhsin M; Ching, Shinung; Chemali, Jessica J; Purdon, Patrick L; Cash, Sydney S; Brown, Emery N
2013-09-30
Develop a real-time algorithm to automatically discriminate suppressions from non-suppressions (bursts) in electroencephalograms of critically ill adult patients. A real-time method for segmenting adult ICU EEG data into bursts and suppressions is presented based on thresholding local voltage variance. Results are validated against manual segmentations by two experienced human electroencephalographers. We compare inter-rater agreement between manual EEG segmentations by experts with inter-rater agreement between human vs automatic segmentations, and investigate the robustness of segmentation quality to variations in algorithm parameter settings. We further compare the results of using these segmentations as input for calculating the burst suppression probability (BSP), a continuous measure of depth-of-suppression. Automated segmentation was comparable to manual segmentation, i.e. algorithm-vs-human agreement was comparable to human-vs-human agreement, as judged by comparing raw EEG segmentations or the derived BSP signals. Results were robust to modest variations in algorithm parameter settings. Our automated method satisfactorily segments burst suppression data across a wide range adult ICU EEG patterns. Performance is comparable to or exceeds that of manual segmentation by human electroencephalographers. Automated segmentation of burst suppression EEG patterns is an essential component of quantitative brain activity monitoring in critically ill and anesthetized adults. The segmentations produced by our algorithm provide a basis for accurate tracking of suppression depth. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Paik, Daehwa; Miyahara, Masaya; Matsuzawa, Akira
This paper analyzes a pseudo-differential dynamic comparator with a dynamic pre-amplifier. The transient gain of a dynamic pre-amplifier is derived and applied to equations of the thermal noise and the regeneration time of a comparator. This analysis enhances understanding of the roles of transistor's parameters in pre-amplifier's gain. Based on the calculated gain, two calibration methods are also analyzed. One is calibration of a load capacitance and the other is calibration of a bypass current. The analysis helps designers' estimation for the accuracy of calibration, dead-zone of a comparator with a calibration circuit, and the influence of PVT variation. The analyzed comparator uses 90-nm CMOS technology as an example and each estimation is compared with simulation results.
Comparative Analysis of River Flow Modelling by Using Supervised Learning Technique
NASA Astrophysics Data System (ADS)
Ismail, Shuhaida; Mohamad Pandiahi, Siraj; Shabri, Ani; Mustapha, Aida
2018-04-01
The goal of this research is to investigate the efficiency of three supervised learning algorithms for forecasting monthly river flow of the Indus River in Pakistan, spread over 550 square miles or 1800 square kilometres. The algorithms include the Least Square Support Vector Machine (LSSVM), Artificial Neural Network (ANN) and Wavelet Regression (WR). The forecasting models predict the monthly river flow obtained from the three models individually for river flow data and the accuracy of the all models were then compared against each other. The monthly river flow of the said river has been forecasted using these three models. The obtained results were compared and statistically analysed. Then, the results of this analytical comparison showed that LSSVM model is more precise in the monthly river flow forecasting. It was found that LSSVM has he higher r with the value of 0.934 compared to other models. This indicate that LSSVM is more accurate and efficient as compared to the ANN and WR model.
Validation of a Computational Fluid Dynamics (CFD) Code for Supersonic Axisymmetric Base Flow
NASA Technical Reports Server (NTRS)
Tucker, P. Kevin
1993-01-01
The ability to accurately and efficiently calculate the flow structure in the base region of bodies of revolution in supersonic flight is a significant step in CFD code validation for applications ranging from base heating for rockets to drag for protectives. The FDNS code is used to compute such a flow and the results are compared to benchmark quality experimental data. Flowfield calculations are presented for a cylindrical afterbody at M = 2.46 and angle of attack a = O. Grid independent solutions are compared to mean velocity profiles in the separated wake area and downstream of the reattachment point. Additionally, quantities such as turbulent kinetic energy and shear layer growth rates are compared to the data. Finally, the computed base pressures are compared to the measured values. An effort is made to elucidate the role of turbulence models in the flowfield predictions. The level of turbulent eddy viscosity, and its origin, are used to contrast the various turbulence models and compare the results to the experimental data.
Freitas, Paulo; Pereira, Sofia A; Santos, Mauro D; Alves, Susana P; Bessa, Rui J B; Delgadillo, Ivonne; Saraiva, Jorge A
2016-11-01
Hyperbaric storage at room temperature (without temperature control) of raw bovine meat was studied and compared to refrigeration. Samples were first stored for 12h at 50, 100 and 150MPa, and in a second set of experiments, for a longer period of 10days at 50MPa. For the 12h storage, refrigeration and 50MPa had a similar microbial growth inhibition effect and, at 100 and 150MPa an additional microbial inactivation effect was found. For the longer experiment (10days at 50MPa) results pointed for a shelf-life increase of raw beef compared to samples stored under refrigeration. For both tests (12h and 10days) samples preserved under pressure showed no detrimental effect on physicochemical parameters comparatively to the initial and refrigerated samples. These results indicate that hyperbaric storage at room temperature not only allows high energy savings, but additionally has potential to extend the shelf-life of a perishable food product compared to refrigeration. Copyright © 2016 Elsevier Ltd. All rights reserved.
Performance of MarSite Multi parameter Borehole Instrumentation
NASA Astrophysics Data System (ADS)
Guralp, Cansun; Tunc, Suleyman; Ozel, Oguz; Meral Ozel, Nurcan; Necmioglu, Ocal
2017-04-01
In this paper we present two year results obtained from the integrated multiparameter borehole system at Marsite. The very broad band (VBB) system have been operating since installation in November 2014; one year in a water filled borehole and one year in a dry Borehole. from January 2016. The real time data has been available to the community. The two Borehole environments are compared showing the superior performance of dry borehole environ- ment compared to water filled for a very broad band (VBB) seismometer. The practical considerations applied in both borehole installations are compared and the best borehole practical installation techniques are presented and discussed. The data is also compared with a surface 120 second broad band sensor and the seismic arrays with in MarSite region. The very long term performance, (one year data in a dry hole) of the VBB Borehole seismometer and the Dilatometer will be presented The high frequency performance of the VBB seismometer which extends to 150 Hz and the dilatometer are compared characterizing the results from the dilatometer.
A comparator-hypothesis account of biased contingency detection.
Vadillo, Miguel A; Barberia, Itxaso
2018-02-12
Our ability to detect statistical dependencies between different events in the environment is strongly biased by the number of coincidences between them. Even when there is no true covariation between a cue and an outcome, if the marginal probability of either of them is high, people tend to perceive some degree of statistical contingency between both events. The present paper explores the ability of the Comparator Hypothesis to explain the general pattern of results observed in this literature. Our simulations show that this model can account for the biasing effects of the marginal probabilities of cues and outcomes. Furthermore, the overall fit of the Comparator Hypothesis to a sample of experimental conditions from previous studies is comparable to that of the popular Rescorla-Wagner model. These results should encourage researchers to further explore and put to the test the predictions of the Comparator Hypothesis in the domain of biased contingency detection. Copyright © 2018 Elsevier B.V. All rights reserved.
Smartphone Assessment of Knee Flexion Compared to Radiographic Standards
Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.
2017-01-01
Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062
B-cell Ligand Processing Pathways Detected by Large-scale Comparative Analysis
Towfic, Fadi; Gupta, Shakti; Honavar, Vasant; Subramaniam, Shankar
2012-01-01
The initiation of B-cell ligand recognition is a critical step for the generation of an immune response against foreign bodies. We sought to identify the biochemical pathways involved in the B-cell ligand recognition cascade and sets of ligands that trigger similar immunological responses. We utilized several comparative approaches to analyze the gene coexpression networks generated from a set of microarray experiments spanning 33 different ligands. First, we compared the degree distributions of the generated networks. Second, we utilized a pairwise network alignment algorithm, BiNA, to align the networks based on the hubs in the networks. Third, we aligned the networks based on a set of KEGG pathways. We summarized our results by constructing a consensus hierarchy of pathways that are involved in B cell ligand recognition. The resulting pathways were further validated through literature for their common physiological responses. Collectively, the results based on our comparative analyses of degree distributions, alignment of hubs, and alignment based on KEGG pathways provide a basis for molecular characterization of the immune response states of B-cells and demonstrate the power of comparative approaches (e.g., gene coexpression network alignment algorithms) in elucidating biochemical pathways involved in complex signaling events in cells. PMID:22917187
Agapova, Maria; Devine, Emily B; Nguyen, Hiep; Wolf, Fredric M; Inoue, Lurdes Y T
2014-07-01
Assessing relative performance among competing interventions is an important part of comparative effectiveness research. Bayesian indirect comparisons add information to existing Cochrane reviews, such as which intervention is likely to perform best. However, heterogeneity variance priors may influence results and, potentially, clinical guidance. We highlight the features of Bayesian indirect comparisons using a case study of a Cochrane review update in asthma care. The probability that one self-management educational intervention outperforms others is estimated. Simulation studies investigate the effect of heterogeneity variance prior distributions. Results suggest a 55% probability that individual education is best, followed by combination (39%) and group (6%). The intervention with few trials was sensitive to prior distributions. Bayesian indirect comparisons updates of Cochrane reviews are valuable comparative effectiveness research tools.
A comparative study of Averrhoabilimbi extraction method
NASA Astrophysics Data System (ADS)
Zulhaimi, H. I.; Rosli, I. R.; Kasim, K. F.; Akmal, H. Muhammad; Nuradibah, M. A.; Sam, S. T.
2017-09-01
In recent year, bioactive compound in plant has become a limelight in the food and pharmaceutical market, leading to research interest to implement effective technologies for extracting bioactive substance. Therefore, this study is focusing on extraction of Averrhoabilimbi by different extraction technique namely, maceration and ultrasound-assisted extraction. Fewplant partsof Averrhoabilimbiweretaken as extraction samples which are fruits, leaves and twig. Different solvents such as methanol, ethanol and distilled water were utilized in the process. Fruit extractsresult in highest extraction yield compared to other plant parts. Ethanol and distilled water have significant role compared to methanol in all parts and both extraction technique. The result also shows that ultrasound-assisted extraction gave comparable result with maceration. Besides, the shorter period on extraction process gives useful in term of implementation to industries.
Krumme, Alexis A; Pawar, Ajinkya; Schneeweiss, Sebastian; Glynn, Robert J; Choudhry, Niteesh K; Kulldorff, Martin; Ortiz, Adrian Santiago; Avorn, Jerome; Gagne, Joshua J
2018-01-01
Since 2010, four oral anticoagulants have been approved for marketing in addition to warfarin for treatment of thromboembolic disease. Limited head-to-head data exist comparing these treatments, leaving patients and clinicians with little guidance for selecting a strategy that balances recurrence reduction with bleeding risk. In the dabigatran, apixaban, rivaroxban, edoxaban and warfarin comparative effectiveness research study, we compare all five currently available oral anticoagulant agents for the extended treatment of deep venous thrombosis and pulmonary embolism, as well as no extended treatment, and evaluate whether results differ in specific sub-populations. As our population includes Medicare novel anticoagulant users and large numbers of commercially insured and Medicaid patients, our results will likely be transportable to the majority of US patients experiencing a DVT or pulmonary embolism. NCT03271450.
How do IMGs compare with Canadian medical school graduates in a family practice residency program?
Andrew, Rodney F.
2010-01-01
ABSTRACT OBJECTIVE To compare international medical graduates (IMGs) with Canadian medical school graduates in a family practice residency program. DESIGN Analysis of the results of the in-training evaluation reports (ITERs) and the Certification in Family Medicine (CCFP) examination results for 2 cohorts of IMGs and Canadian-trained graduates between the years 2006 and 2008. SETTING St Paul’s Hospital (SPH) in Vancouver, BC, a training site of the University of British Columbia (UBC) Family Practice Residency Program. PARTICIPANTS In-training evaluation reports were examined for 12 first-year and 9 second-year Canadian-trained residents at the SPH site, and 12 first-year and 12 second-year IMG residents at the IMG site at SPH; CCFP examination results were reviewed for all UBC family practice residents who took the May 2008 examination and disclosed their results. MAIN OUTCOME MEASURES Pass or fail rates on the CCFP examination; proportions of evaluations in each group of residents given each of the following designations: exceeds expectations, meets expectations, or needs improvement. The May 2008 CCFP examination results were reviewed. RESULTS Compared with the second-year IMGs, the second-year SPH Canadian-trained residents had a greater proportion of exceeds expectations designations than the IMGs. For the first-year residents, both the SPH Canadian graduates and IMGs had similar results in all 3 categories. Combining the results of the 2 cohorts, the Canadian-trained residents had 310 (99%) ITERs that were designated as either exceeds expectations or meets expectations, and only 3 (1%) ITERs were in the needs improvement category. The IMG results were 362 (97.6%) ITERs in the exceeds expectations or meets expectations categories; 9 (2%) were in the needs improvement category. Statistically these are not significant differences. Seven of the 12 (58%) IMG candidates passed the CCFP examination compared with 59 of 62 (95%) of the UBC family practice residents. CONCLUSION The IMG residents compared favourably with their Canadian-trained colleagues when comparing ITERs but not in passing the CCFP examination. Further research is needed to elucidate these results. PMID:20841570
EDGAR: A software framework for the comparative analysis of prokaryotic genomes
Blom, Jochen; Albaum, Stefan P; Doppmeier, Daniel; Pühler, Alfred; Vorhölter, Frank-Jörg; Zakrzewski, Martha; Goesmann, Alexander
2009-01-01
Background The introduction of next generation sequencing approaches has caused a rapid increase in the number of completely sequenced genomes. As one result of this development, it is now feasible to analyze large groups of related genomes in a comparative approach. A main task in comparative genomics is the identification of orthologous genes in different genomes and the classification of genes as core genes or singletons. Results To support these studies EDGAR – "Efficient Database framework for comparative Genome Analyses using BLAST score Ratios" – was developed. EDGAR is designed to automatically perform genome comparisons in a high throughput approach. Comparative analyses for 582 genomes across 75 genus groups taken from the NCBI genomes database were conducted with the software and the results were integrated into an underlying database. To demonstrate a specific application case, we analyzed ten genomes of the bacterial genus Xanthomonas, for which phylogenetic studies were awkward due to divergent taxonomic systems. The resultant phylogeny EDGAR provided was consistent with outcomes from traditional approaches performed recently and moreover, it was possible to root each strain with unprecedented accuracy. Conclusion EDGAR provides novel analysis features and significantly simplifies the comparative analysis of related genomes. The software supports a quick survey of evolutionary relationships and simplifies the process of obtaining new biological insights into the differential gene content of kindred genomes. Visualization features, like synteny plots or Venn diagrams, are offered to the scientific community through a web-based and therefore platform independent user interface , where the precomputed data sets can be browsed. PMID:19457249
Case Studies Comparing System Advisor Model (SAM) Results to Real Performance Data: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blair, N.; Dobos, A.; Sather, N.
2012-06-01
NREL has completed a series of detailed case studies comparing the simulations of the System Advisor Model (SAM) and measured performance data or published performance expectations. These case studies compare PV measured performance data with simulated performance data using appropriate weather data. The measured data sets were primarily taken from NREL onsite PV systems and weather monitoring stations.
ERIC Educational Resources Information Center
Hooper, Jeff; Wigram, Tony; Carson, Derek; Lindsay, Bill
2011-01-01
Previous researchers who compared how people with, and without, an intellectual disability respond to music focused on musical aptitude, but not on arousal. This paper presents the background, methodology, and results of a study that selected fifteen different pieces of music, and compared the arousal response of adults with (n = 48), and without…
ERIC Educational Resources Information Center
Trotter, Kay Sudekum; Chandler, Cynthia K.; Goodwin-Bond, Deborah; Casey, Janie
2008-01-01
This study demonstrates the efficacy of Equine Assisted Counseling (EAC) by comparing EAC to classroom-based counseling. Students (n = 164) identified as being at high risk for academic and/or social failure participated in 12 weekly counseling sessions. Within-group paired sample t-test results comparing pre- and post-treatment scores for…
Soulié, M; Salomon, L
2015-11-01
Review of the comparative results of different treatment strategies (surgery, radiotherapy, ultrasound, surveillance) of prostate cancer, in which the main goal is the local control and the second target is the tolerance of the side effects of those treatments. Review of literature using Medline databases selected based on scientific relevance. Clinical keys centered on the oncological and functional outcomes of comparative series between different curative treatments. The numerous comparative series between surgery and other therapeutic modalities are essentially retrospective with significant methodological bias that is difficult to overcome in order to formulate the optimal thesis. However, there is a clear tendency toward surgery usually with young patients who have intermediate risk tumors without important comorbidity. In the absence of randomized comparative series with significant power, the oncological and functional results of the radical prostatectomy with or without adjuvant treatment seem at least the same, in a selected population of patients, compared with the combination of radiotherapy-hormonotherapy in terms of survival, without biochemical recurrence, disease-specific survival and overall survival, for the aggressive tumors necessitating curative local treatments. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Katle, E J; Hatlebakk, J G; Grimstad, T; Kvaløy, J T; Steinsvåg, S K
2017-03-01
The pathophysiology of chronic rhinosinusitis (CRS) is unclear. It has been discussed for decades whether gastro-oesophageal reflux (GOR) may be a contributing factor for some patients. The aim of the present study was to evaluate the level of GOR in an unselected group of patients with CRS using multichannel impedance-pH monitoring. Consecutive patients with CRS diagnosed using the EPOS2012 criteria, completed questionnaires on GOR symptoms and were offered 24-h multichannel intraluminal impedance (MII)-pH monitoring. The results were compared with a group of healthy controls. Forty-six patients completed MII-pH-monitoring and were compared with 45 control subjects, with comparable age and gender distributions. The median number of reflux episodes in the patients was 56.5 compared with 33 in controls, while, the numbers of proximal reflux episodes was 27.5 versus 3, respectively. Thirty nine patients had abnormal pH-impedance recordings compared with five controls. The CRS patients had significantly higher incidences of gastro-oesophageal reflux compared with asymptomatic controls. The results of this study suggest that GOR may be a causative or contributing factor of CRS.
Panev, T
1991-01-01
The present work has the purpose to make a comparative evaluation of the different types detector tubes--for analysis, long-term and passive for determination of NO2 and the results to be compared, with those received by the spectrophotometric method and the reagent of Zaltsman. Studies were performed in the hall of the garage for repair of diesel buses during one working shift. The results point out that the analysing tubes for NO2 give good results with the spectrophotometric method. The measured average-shift concentrations of NO2 by long-term and passive tubes are juxtaposed with the average-received values with the analytical tubes and with the analytical method.
Objective measurements to evaluate glottal space segmentation from laryngeal images.
Gutiérrez-Arriola, J M; Osma-Ruiz, V; Sáenz-Lechón, N; Godino-Llorente, J I; Fraile, R; Arias-Londoño, J D
2012-01-01
Objective evaluation of the results of medical image segmentation is a known problem. Applied to the task of automatically detecting the glottal area from laryngeal images, this paper proposes a new objective measurement to evaluate the quality of a segmentation algorithm by comparing with the results given by a human expert. The new figure of merit is called Area Index, and its effectiveness is compared with one of the most used figures of merit found in the literature: the Pratt Index. Results over 110 laryngeal images presented high correlations between both indexes, demonstrating that the proposed measure is comparable to the Pratt Index and it is a good indicator of the segmentation quality.
NASA Technical Reports Server (NTRS)
Iben, I., Jr.
1971-01-01
Survey of recently published studies on globular clusters, and comparison of stellar evolution and pulsation theory with reported observations. The theory of stellar evolution is shown to be capable of describing, in principle, the behavior of a star through all quasi-static stages. Yet, as might be expected, estimates of bulk properties obtained by comparing observations with results of pulsation and stellar atmosphere theory differ somewhat from estimates of these same properties obtained by comparing observations with results of evolution theory. A description is given of how such estimates are obtained, and suggestions are offered as to where the weak points in each theory may lie.
Nherera, Leo M; Woodmansey, Emma; Trueman, Paul; Gibbons, Garry W
2016-06-01
Chronic venous leg ulcers (VLUs) affect up to 1% of the adult population in the developed world and present a significant financial and resource burden to health care systems. Cadexomer iodine (CI) is an antimicrobial dressing indicated for use in chronic exuding wounds. The aim of this study was to estimate the cost utility of using CI + standard care (SC) - ie, high compression multicomponent bandaging including debridement - compared with SC alone in the management of chronic (>6 months' duration) VLUs from a payer's perspective. A Markov model was constructed to evaluate the cost and clinical benefits (healing and decreased infection rates) of the 2 treatment modalities over a 1-year period using data from 4 randomized, controlled clinical studies (RCTs) included in a recent Cochrane review and cost data from a recently published economic evaluation of VLUs. Costs were calculated using 2014 United States dollars; wound outcomes in- cluded complete healing in 212 patients reported in the Cochrane meta-analysis and quality-adjusted life years (QALYs), with utility values obtained from 200 patients with VLUs calculated using standard gamble. Treatment with CI over 1 year was $7,259 compared to $7,901 for SC. This resulted in a cost savings of $643/patient in favor of CI compared with SC. More patients treated with CI (61%) had their wounds healed compared to 54% treated with SC. Furthermore, patients treated with CI+SC experienced 6 additional ulcer-free weeks compared to persons treated with SC alone (ie, 25 ulcer- free weeks compared to 19 ulcer-free weeks, respectively). Overall, CI resulted in 0.03 more QALYs (ie, 0.86 QALYs compared to 0.83 for SC). The use of CI in addition to SC compared to SC alone over 52 weeks resulted in more wounds healed and more QALYs along with a decrease of overall costs The results of this study suggest CI is cost effective com- pared to SC alone in the management of patients with chronic VLUs. Prospective, controlled clinical studies are needed to elucidate the effect and cost effectiveness of CI on VLUs with and without signs of infection as compared to SC, other antiseptics, and more advanced topical treatment modalities.
Crawford, Cindy; Boyd, Courtney; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Yang, EunMee; Zhang, Weimin
2016-07-01
Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life outcomes across all pain populations. Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Sixty high quality and seven low quality studies were included in the review. Results demonstrate massage therapy effectively treats pain compared to sham [standardized mean difference (SMD) = -.44], no treatment (SMD = -1.14), and active (SMD = -0.26) comparators. Compared to active comparators, massage therapy was also beneficial for treating anxiety (SMD = -0.57) and health-related quality of life (SMD = 0.14). Based on the evidence, massage therapy, compared to no treatment, should be strongly recommended as a pain management option. Massage therapy is weakly recommended for reducing pain, compared to other sham or active comparators, and improving mood and health-related quality of life, compared to other active comparators. Massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option are discussed.
Structural outcomes in the Cleft Care UK study. Part 2: dento-facial outcomes
Al-Ghatam, R; Jones, T E M; Ireland, A J; Atack, N E; Chawla, O; Deacon, S; Albery, L; Cobb, A R M; Cadogan, J; Leary, S; Waylen, A; Wills, A K; Richard, B; Bella, H; Ness, A R; Sandy, J R
2015-01-01
Structured Abstract Objectives To compare facial appearance and dento-alveolar relationship outcomes from the CSAG (1998) and CCUK (2013) studies. Setting and sample population Five-year-olds born with non-syndromic unilateral cleft lip and palate. Those in the original CSAG were treated in a dispersed model of care with low-volume operators. Those in CCUK were treated in a more centralized, high-volume operator model. Materials and methods We compared facial appearance using frontal view photographs (252 CCUK, 239 CSAG) and dental relationships using study models (198 CCUK, 223 CSAG). Facial appearance was scored by a panel of six assessors using a standardized and validated outcome tool. Dento-alveolar relationships were scored by two assessors using the 5-Year-Olds’ Index. Ordinal regression was used to compare results between surveys. Results Excellent or good facial appearance was seen in 36.2% of CCUK compared with 31.9% in CSAG. In CCUK, 21.6% were rated as having poor or very poor facial appearance compared with 27.6% in CSAG. The percentage rated as having excellent or good dento-alveolar relationships was 53.0% in CCUK compared with 29.6% in CSAG. In CCUK, 19.2% were rated as having poor or very poor dento-alveolar relationships compared to 36.3% in CSAG. The odds ratios for improved outcome in CCUK compared to CSAG were 1.43 (95% CI 1.03, 1.97) for facial appearance and 2.29 (95% CI 1.47, 3.55) for dento-alveolar relationships. Conclusions Facial and dento-alveolar outcomes were better in CCUK children compared to those in CSAG. PMID:26567852
Morton, Reeva C; Gadke, Daniel L
2018-03-01
Cover, Copy, Compare (CCC) and Copy, Cover, Compare (MCCC) procedures are effective interventions for improving math fluency. However, there is a gap in literature exploring the use of these interventions for children with autism spectrum disorders (ASD). The purpose of the current study was to compare the use of CCC and MCCC for children with ASD using a multi-component single-case experimental design. The results showed no notable difference between the interventions. Implications and limitations, particularly surrounding experimental control, are discussed in detail.
Are STEM High School Students Entering the STEM Pipeline?
ERIC Educational Resources Information Center
Franco, M. Suzanne; Patel, Nimisha H.; Lindsey, Jill
2012-01-01
This study compared the career skills and interests for students in two STEM schools to national data. Students completed the KUDER skills assessment and career planning online tools. Results were compared across school, grade level, and sex. The results provided evidence that STEM high school students expressed career intents in predominately…
Effectiveness of an Online Graduate Preparation Program
ERIC Educational Resources Information Center
Brucato, Brittany; Neimeyer, Greg J.
2011-01-01
The present study reports the results of a controlled examination of the effectiveness of an online graduate preparation program, the Virtual Advisor. The effects of the Virtual Advisor were compared to a website preparation group and a wait-list control group. Results indicated that, compared to the control group, students who utilized the…
Annual health examination program, Ames Research Center
NASA Technical Reports Server (NTRS)
Hughes, L.; Ladou, J.
1975-01-01
A cost analysis of a low-volume multiphasic health testing program is presented. The results indicate that unit costs are similar to those of high-volume automated programs. The comparability in unit cost appears to result from the savings in personnel and space requirements of the smaller program as compared with the larger ones.
USDA-ARS?s Scientific Manuscript database
Copy number variations (CNV) are well known genomic variants, which often complicate structural and functional genomics studies. Here, we integrated the CNV region (CNVR) result detected from 1,682 Nellore cattle with the equivalent result derived from the Bovine HapMap samples. Through comparing CN...
ERIC Educational Resources Information Center
Marchis, Iuliana
2009-01-01
The results of the Romanian pupils on international tests PISA and TIMSS in Mathematics are below the average. These poor results have many explications. In this article we compare the Mathematics problems given on these international tests with those given on national tests in Romania.
ERIC Educational Resources Information Center
Wise, Dena; Sneed, Christopher; Velandia, Margarita; Berry, Ann; Rhea, Alice; Fairhurst, Ann
2013-01-01
The Local Table project compared results from parallel surveys of consumers and restaurateurs regarding local food purchasing and use. Results were also compared with producers' perception of, capacity for and participation in direct marketing through local venues, on-farm outlets, and restaurants. The surveys found consumers' and restaurateurs'…
Reed-Muller Codes in Error Correction in Wireless Adhoc Networks
2004-03-01
resulting spectrum is the spectrum of the windowed signal. Therefore, the window width is an important pa- rameter that affects the BER performanceof ... compare the results, the same random message was used. The seed value in msg.m was changed only for comparing the PAPR values of the system with
Examining Marketing Journals' Publication Process and Reviewer Practices
ERIC Educational Resources Information Center
Seiler, Vicky L.; Reisenwitz, Timothy H.; Schibrowsky, John A.
2011-01-01
This study examines reviewer practices at 11 marketing journals. The results for the top three journals are compared to eight comparable journals that are typically considered to be non-top-tier journals. The results suggest that the reviewers and the review processes at the top journals differ significantly from those of the non-top-tier…
How beneficial is vaping cannabis to respiratory health compared to smoking?
Tashkin, Donald P
2015-11-01
While vaping cannabis reduces respiratory exposure to toxic particulates in cannabis smoke, the resultant reduction in clinically evident harms to lung health is probably smaller than that likely to result from substituting e-cigarettes for smoked tobacco due to the comparatively greater harms of tobacco than cannabis smoking to lung health.
Validation and Verification of Composite Pressure Vessel Design
NASA Technical Reports Server (NTRS)
Kreger, Stephen T.; Ortyl, Nicholas; Grant, Joseph; Taylor, F. Tad
2006-01-01
Ten composite pressure vessels were instrumented with fiber Bragg grating sensors and pressure tested Through burst. This paper and presentation will discuss the testing methodology, the test results, compare the testing results to the analytical model, and also compare the fiber Bragg grating sensor data with data obtained against that obtained from foil strain gages.
Allen, Y.C.; Wilson, C.A.; Roberts, H.H.; Supan, J.
2005-01-01
Sidescan sonar holds great promise as a tool to quantitatively depict the distribution and extent of benthic habitats in Louisiana's turbid estuaries. In this study, we describe an effective protocol for acoustic sampling in this environment. We also compared three methods of classification in detail: mean-based thresholding, supervised, and unsupervised techniques to classify sidescan imagery into categories of mud and shell. Classification results were compared to ground truth results using quadrat and dredge sampling. Supervised classification gave the best overall result (kappa = 75%) when compared to quadrat results. Classification accuracy was less robust when compared to all dredge samples (kappa = 21-56%), but increased greatly (90-100%) when only dredge samples taken from acoustically homogeneous areas were considered. Sidescan sonar when combined with ground truth sampling at an appropriate scale can be effectively used to establish an accurate substrate base map for both research applications and shellfish management. The sidescan imagery presented here also provides, for the first time, a detailed presentation of oyster habitat patchiness and scale in a productive oyster growing area.
Summary of recent NASA propeller research
NASA Technical Reports Server (NTRS)
Mikkelson, D. C.; Mitchell, G. A.; Bober, L. J.
1984-01-01
Advanced high-speed propellers offer large performance improvements for aircraft that cruise in the Mach 0.7 to 0.8 speed regime. At these speeds, studies indicate that there is a 15 to near 40 percent block fuel savings and associated operating cost benefits for advanced turboprops compared to equivalent technology turbofan powered aircraft. Recent wind tunnel results for five eight to ten blade advanced models are compared with analytical predictions. Test results show that blade sweep was important in achieving net efficiencies near 80 percent at Mach 0.8 and reducing nearfield cruise noise by about 6 dB. Lifting line and lifting surface aerodynamic analysis codes are under development and some results are compared with propeller force and probe data. Also, analytical predictions are compared with some initial laser velocimeter measurements of the flow field velocities of an eightbladed 45 swept propeller. Experimental aeroelastic results indicate that cascade effects and blade sweep strongly affect propeller aeroelastic characteristics. Comparisons of propeller near-field noise data with linear acoustic theory indicate that the theory adequately predicts near-field noise for subsonic tip speeds but overpredicts the noise for supersonic tip speeds.
Summary of recent NASA propeller research
NASA Technical Reports Server (NTRS)
Mikkelson, D. C.; Mitchell, G. A.; Bober, L. J.
1985-01-01
Advanced high speed propellers offer large performance improvements for aircraft that cruise in the Mach 0.7 to 0.8 speed regime. At these speeds, studies indicate that there is a 15 to near 40 percent block fuel savings and associated operating cost benefits for advanced turboprops compared to equivalent technology turbofan powered aircraft. Recent wind tunnel results for five eight to ten blade advanced models are compared with analytical predictions. Test results show that blade sweep was important in achieving net efficiencies near 80 percent at Mach 0.8 and reducing nearfield cruise noise about 6 dB. Lifting line and lifting surface aerodynamic analysis codes are under development and some results are compared with propeller force and probe data. Also, analytical predictions are compared with some initial laser velocimeter measurements of the flow field velocities of an eight bladed 45 swept propeller. Experimental aeroelastic results indicate that cascade effects and blade sweep strongly affect propeller aeroelastic characteristics. Comparisons of propeller nearfield noise data with linear acoustic theory indicate that the theory adequately predicts nearfield noise for subsonic tip speeds, but overpredicts the noise for supersonic tip speeds.
Environmental implications of wireless technologies: news delivery and business meetings.
Toffel, Michael W; Horvath, Arpad
2004-06-01
Wireless information technologies are providing new ways to communicate, and are one of several information and communication technologies touted as an opportunity to reduce society's overall environmental impacts. However, rigorous system-wide environmental impact comparisons of these technologies to the traditional applications they may replace have only recently been initiated, and the results have been mixed. In this paper, the environmental effects of two applications of wireless technologies are compared to those of conventional technologies for which they can substitute. First, reading newspaper content on a personal digital assistant (PDA) is compared to the traditional way of reading a newspaper. Second, wireless teleconferencing is compared to business travel. The results show that for both comparisons wireless technologies create lower environmental impacts. Compared to reading a newspaper, receiving the news on a PDA wirelessly results in the release of 32-140 times less CO2, several orders of magnitude less NOx and SOx, and the use of 26-67 times less water. Wireless teleconferencing results in 1-3 orders of magnitude lower CO2, NOx, and SO2 emissions than business travel.
Intrathecal opioids versus epidural local anesthetics for labor analgesia: a meta-analysis.
Bucklin, Brenda A; Chestnut, David H; Hawkins, Joy L
2002-01-01
Some anesthesiologists contend that intrathecal opioid administration has advantages over conventional epidural techniques during labor. Randomized clinical trials comparing analgesia and obstetric outcome using single-injection intrathecal opioids versus epidural local anesthetics suggest that intrathecal opioids provide comparable analgesia with few serious side effects. This meta-analysis compared the analgesic efficacy, side effects, and obstetric outcome of single-injection intrathecal opioid techniques versus epidural local anesthetics in laboring women. Relevant clinical studies were identified using electronic and manual searches of the literature covering the period from 1989 to 2000. Searches used the following descriptors: intrathecal analgesia, spinal opioids, epidural analgesia, epidural local anesthetics, and analgesia for labor. Data were extracted from 7 randomized clinical trials comparing analgesic measures, incidence of motor block, pruritus, nausea, hypotension, mode of delivery, and/or Apgar scores. Combined test results indicated comparable analgesic efficacy 15 to 20 minutes after injection with single-injection intrathecal opioid administration. Intrathecal opioid injections were associated with a greater incidence of pruritus (odds ratio, 14.01; 99% confidence interval, 6.9 to 28.3), but there was no difference in the incidence of nausea or in the method of delivery. Published studies suggest that intrathecal opioids provide comparable early labor analgesia when compared with epidural local anesthetics. Intrathecal opioid administration results in a greater incidence of pruritus. The choice of technique does not appear to affect the method of delivery.
Teaching Business Simulation Games: Comparing Achievements Frontal Teaching vs. eLearning
NASA Astrophysics Data System (ADS)
Bregman, David; Keinan, Gila; Korman, Arik; Raanan, Yossi
This paper addresses the issue of comparing results achieved by students taught the same course but in two drastically different - a regular, frontal method and an eLearning method. The subject taught required intensive communications among the students, thus making the eLearning students, a priori, less likely to do well in it. The research, comparing the achievements of students in a business simulation game over three semesters, shows that the use of eLearning method did not result in any differences in performance, grades or cooperation, thus strengthening the case for using eLearning in this type of course.
Duinslaeger, L A; Verbeken, G; Vanhalle, S; Vanderkelen, A
1997-01-01
Donor site treatment is a crucial issue in the treatment of extensive burns. In this single-blind, randomized study treatment of donor sites with a polyurethane dressing, Op-Site (Smith & Nephew, York, U.K.) is compared to treatment with allogeneic cultured keratinocyte sheets. Results show a mean healing time of 6.7 days with use of cultured keratinocyte sheets compared to mean healing time of 13.6 days with Op-Site treatment. Also, improvement in the comfort of patients as the result of less exudate formation and pain attenuation was noted.
NASA Astrophysics Data System (ADS)
Ahmed, Asif; Ferdous, Imam Ul.; Saha, Sumon
2017-06-01
In the present study, three-dimensional numerical simulation of two shell-and-tube heat exchangers (STHXs) with conventional segmental baffles (STHXsSB) and continuous helical baffle (STHXsHB) is carried out and a comparative study is performed based on the simulation results. Both of the STHXs contain 37 tubes inside a 500 mm long and 200 mm diameter shell and mass flow rate of shell-side fluid is varied from 0.5 kg/s to 2 kg/s. At first, physical and mathematical models are developed and numerically simulated using finite element method (FEM). For the validation of the computational model, shell-side average nusselt number (Nus) is calculated from the simulation results and compared with the available experimental results. The comparative study shows that STHXsHB has 72-127% higher heat transfer coefficient per unit pressure drop compared to the conventional STHXsSB for the same shell-side mass flow rate. Moreover, STHXsHB has 59-63% lower shell-side pressure drop than STHXsSB.
NASA Astrophysics Data System (ADS)
Jang, Yujin; Huh, Jinbum; Lee, Namhun; Lee, Seungsoo; Park, Youngmin
2018-04-01
The RANS equations are widely used to analyze complex flows over aircraft. The equations require a turbulence model for turbulent flow analyses. A suitable turbulence must be selected for accurate predictions of aircraft aerodynamic characteristics. In this study, numerical analyses of three-dimensional aircraft are performed to compare the results of various turbulence models for the prediction of aircraft aerodynamic characteristics. A 3-D RANS solver, MSAPv, is used for the aerodynamic analysis. The four turbulence models compared are the Sparlart-Allmaras (SA) model, Coakley's q-ω model, Huang and Coakley's k-ɛ model, and Menter's k-ω SST model. Four aircrafts are considered: an ARA-M100, DLR-F6 wing-body, DLR-F6 wing-body-nacelle-pylon from the second drag prediction workshop, and a high wing aircraft with nacelles. The CFD results are compared with experimental data and other published computational results. The details of separation patterns, shock positions, and Cp distributions are discussed to find the characteristics of the turbulence models.
du Plessis, Lissinda H; Govender, Katya; Denti, Paolo; Wiesner, Lubbe
2015-11-01
The oral absorption of compounds with low aqueous solubility, such as lumefantrine, is typically limited by the dissolution rate in the gastro-intestinal tract, resulting in erratic absorption and highly variable bioavailability. In previous studies we reported on the ability of Pheroid vesicles to improve the bioavailability of poorly soluble drugs. In the present study a Pro-Pheroid formulation, a modification of the previous formulation, was applied to improve the solubility of lumefantrine after oral administration and compared to lumefantrine in DMSO:water (1:9 v/v) solution (reference solution). A bioavailability study of lumefantrine was conducted in a mouse model in fed and fasted states. When using the reference solution, the bioavailability of the lumefantrine heavily depended on food intake, resulting in a 2.7 times higher bioavailability in the fed state when compared to the fasted state. It also showed large between-subject variability. When formulated using Pro-Pheroid, the bioavailability of lumefantrine was 3.5 times higher as compared to lumefantrine in the reference solution and fasting state. Pro-Pheroid also dramatically reduced the effects of food intake and the between-subject variability for bioavailability observed with the reference. In vivo antimalarial efficacy was also evaluated with lumefantrine formulated using Pro-Pheroid technology compared to the reference solution. The results indicated that lumefantrine in Pro-Pheroid formulation exhibited improved antimalarial activity in vitro by 46.8%, when compared to the reference. The results of the Peters' 4-day suppressive test indicated no significant difference in the efficacy or mean survival time of the mice in the Pro-Pheroid formulation and reference test groups when compared to the positive control, chloroquine. These findings suggest that using the Pro-Pheroid formulation improves the bioavailability of lumefantrine, eliminates the food effect associated with lumefantrine as well as significantly reduces the between subject variability in bioavailability when compared to the reference solution. Copyright © 2015 Elsevier B.V. All rights reserved.
Modal analysis and acoustic transmission through offset-core honeycomb sandwich panels
NASA Astrophysics Data System (ADS)
Mathias, Adam Dustin
The work presented in this thesis is motivated by an earlier research that showed that double, offset-core honeycomb sandwich panels increased thermal resistance and, hence, decreased heat transfer through the panels. This result lead to the hypothesis that these panels could be used for acoustic insulation. Using commercial finite element modeling software, COMSOL Multiphysics, the acoustical properties, specifically the transmission loss across a variety of offset-core honeycomb sandwich panels, is studied for the case of a plane acoustic wave impacting the panel at normal incidence. The transmission loss results are compared with those of single-core honeycomb panels with the same cell sizes. The fundamental frequencies of the panels are also computed in an attempt to better understand the vibrational modes of these particular sandwich-structured panels. To ensure that the finite element analysis software is adequate for the task at hand, two relevant benchmark problems are solved and compared with theory. Results from these benchmark results compared well to those obtained from theory. Transmission loss results from the offset-core honeycomb sandwich panels show increased transmission loss, especially for large cell honeycombs when compared to single-core honeycomb panels.
Green, Douglas H.; Wurzinger, Brian
2012-01-01
Purpose/Background: Both forefoot strike shod (FFS) and barefoot (BF) running styles result in different mechanics when compared to rearfoot strike (RFS) shod running. Additionally, running mechanics of FFS and BF running are similar to one another. Comparing the mechanical changes occurring in each of these patterns is necessary to understand potential benefits and risks of these running styles. The authors hypothesized that FFS and BF conditions would result in increased sagittal plane joint angles at initial contact and that FFS and BF conditions would demonstrate a shift in sagittal plane joint power from the knee to the ankle when compared to the RFS condition. Finally, total lower extremity power absorption will be least in BF and greatest in the RFS shod condition. Methods: The study included 10 male and 10 female RFS runners who completed 3‐dimensional running analysis in 3 conditions: shod with RFS, shod with FFS, and BF. Variables were the angles of plantarflexion, knee flexion, and hip flexion at initial contact and peak sagittal plane joint power at the hip, knee, and ankle during stance phase. Results: Running with a FFS pattern and BF resulted in significantly greater plantarflexion and significantly less negative knee power (absorption) when compared to shod RFS condition. FFS condition runners landed in the most plantarflexion and demonstrated the most peak ankle power absorption and lowest knee power absorption between the 3 conditions. BF and FFS conditions demonstrated decreased total lower extremity power absorption compared to the shod RFS condition but did not differ from one another. Conclusions: BF and FFS running result in reduced total lower extremity power, hip power and knee power and a shift of power absorption from the knee to the ankle. Clinical Relevance: Alterations associated with BF running patterns are present in a FFS pattern when wearing shoes. Additionally, both patterns result in increased demand at the foot and ankle as compared to the knee. PMID:23091785
The results of nucleic acid testing in remunerated and non-remunerated blood donors in Lithuania
Kalibatas, Vytenis; Kalibatienė, Lina
2014-01-01
Background In Lithuania, governmentally covered remuneration for whole blood donations prevails. Donors may choose to accept or reject the remuneration. The purpose of this study was to compare the rate of nucleic acid testing (NAT) discriminatory-positive markers for human immunodeficiency virus-1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) in seronegative, first-time and repeat, remunerated and non-remunerated donations at the National Blood Centre in Lithuania during the period from 2005 to 2010. Materials and methods All seronegative whole blood and blood component donations were individually analysed by NAT for HIV-1, HBV and HCV. Only discriminatory-positive NAT were classified. The prevalence of discriminatory-positive NAT per 100,000 donations in the donor groups and the odds ratios comparing the remunerated and non-remunerated donations were determined. Results Significant differences were observed for HBV NAT results: 47.42 and 26.29 per 100,000 remunerated first-time and repeat donations, respectively, compared to 10.6 and 3.58 per 100,000 non-remunerated first-time and repeat, seronegative donations, respectively. The differences were also significant for HCV NAT results: 47.42 and 51.99 for remunerated first-time and repeat donations, respectively, compared to 2.12 and 0 per 100,000 non-remunerated first-time and repeat, seronegative donations, respectively. No seronegative, discriminatory-positive NAT HIV case was found. The odds of discriminatory HBV and HCV NAT positive results were statistically significantly higher for both first-time and repeat remunerated donations compared to first-time and repeat non-remunerated donations. Discussion First-time and repeat remunerated seronegative donations were associated with a statistically significantly higher prevalence and odds for discriminatory-positive HBV and HCV NAT results compared to first-time and repeat non-remunerated donations at the National Blood Centre in Lithuania. PMID:24120587
NASA Astrophysics Data System (ADS)
Heinz, Jana; Enghag, Margareta; Stuchlikova, Iva; Cakmakci, Gultekin; Peleg, Ran; Baram-Tsabari, Ayelet
2017-09-01
This empirical study investigates factors that influence the implementation of science inquiry in the education systems of Turkey, Israel, Sweden and the Czech Republic. Data was collected by means of recordings of science experts' discussions as part of an EU-funded project called Science-Teacher Education Advanced Methods (2009-2012). Results of the qualitative analysis reveal that the following general indicators provide insight into the extent of implementation of inquiry-based science education (IBSE): (1) curriculum (2) assessment (3) policy and (4) teacher professionalization systems. In a second step comparative analyses of the four countries' education systems were conducted with regard to these indicators. To compare these factors we refer to both the framework of neo-institutional theories that explore the emergence of isomorphic educational models and to results from comparative studies emphasizing the influence of the countries' individual structure and cultural practices on modifying global pressure to convergence. Results show that in each of the countries these indicators influence the implementation of science inquiry to varying degrees. Moreover, as a result of the comparative analyses further country specific factors important for implementing science inquiry were found: (5) the need to improve existing teaching methods, (6) predominant teaching patterns, (7) infrastructure that enables changes in education and (8) education system's general goals that correlate with reforms.
Urner, Martin; Twerenbold, Claudia; Kern, Sabine; Brügger, Urs; Spahn, Donat R.; Beck-Schimmer, Beatrice; Ganter, Michael T.
2017-01-01
BACKGROUND: Pharmacologic pre- and postconditioning with sevoflurane compared with total IV anesthesia in patients undergoing liver surgery reduced complication rates as shown in 2 recent randomized controlled trials. However, the potential health economic consequences of these different anesthesia regimens have not yet been assessed. METHODS: An expostcost analysis of these 2 trials in 129 patients treated between 2006 and 2010 was performed. We analyzed direct medical costs for in-hospital stay and compared pharmacologic pre- and postconditioning with sevoflurane (intervention) with total IV anesthesia (control) from the perspective of a Swiss university hospital. Year 2015 costs, converted to US dollars, were derived from hospital cost accounting data and compared with a multivariable regression analysis adjusting for relevant covariables. Costs with negative prefix indicate savings and costs with positive prefix represent higher spending in our analysis. RESULTS: Treatment-related costs per patient showed a nonsignificant change by −12,697 US dollars (95% confidence interval [CI], 10,956 to −36,352; P = .29) with preconditioning and by −6139 US dollars (95% CI, 6723 to −19,000; P = .35) with postconditioning compared with the control group. Results were robust in our sensitivity analysis. For both procedures (control and intervention) together, major complications led to a significant increase in costs by 86,018 US dollars (95% CI, 13,839-158,198; P = .02) per patient compared with patients with no major complications. CONCLUSIONS: In this cost analysis, reduced in-hospital costs by pharmacologic conditioning with sevoflurane in patients undergoing liver surgery are suggested. This possible difference in costs compared with total IV anesthesia is the result of reduced complication rates with pharmacologic conditioning, because major complications have significant cost implications. PMID:28067701
Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria
2018-04-25
The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.
Boyd, Courtney; Crawford, Cindy; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Zhang, Weimin; Buckenmaier, Chester; Buckenmaier, Pamela; Cambron, Jerrilyn; Deery, Christopher; Schwartz, Jan; Werner, Ruth; Whitridge, Pete
2016-01-01
Abstract Purpose Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life in cancer populations. Methods Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using the SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Results Twelve high quality and four low quality studies were subsequently included in the review. Results demonstrate massage therapy is effective for treating pain compared to no treatment [standardized mean difference (SMD) = −.20] and active (SMD = −0.55) comparators. Compared to active comparators, massage therapy was also found to be beneficial for treating fatigue (SMD = −1.06) and anxiety (SMD = −1.24). Conclusion Based on the evidence, weak recommendations are suggested for massage therapy, compared to an active comparator, for the treatment of pain, fatigue, and anxiety. No recommendations were suggested for massage therapy compared to no treatment or sham control based on the available literature to date. This review addresses massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option for cancer pain populations. PMID:27165967
Effects of nandrolone decanoate compared with placebo or testosterone on HIV-associated wasting.
Gold, J; Batterham, M J; Rekers, H; Harms, M K; Geurts, T B P; Helmyr, P M E; Silva de Mendonça, J; Falleiros Carvalho, L H; Panos, G; Pinchera, A; Aiuti, F; Lee, C; Horban, A; Gatell, J; Phanuphak, P; Prasithsirikul, W; Gazzard, B; Bloch, M; Danner, S A
2006-04-01
Objectives Current research is unclear about the most effective pharmacological agents for managing the loss of weight and fat-free mass common in HIV/AIDS. The aim of this study was to compare nandrolone decanoate with placebo and testosterone. Methods The study was a multicentre randomized double-blind placebo-controlled trial. Three hundred and three adult HIV-positive male patients with a weight loss of 5-15% in the last 12 months, or a body mass index of 17-19 kg/m(2), or a body cell mass/height ratio lower than 13.5 kg/m, were randomly assigned to receive nandrolone decanoate (150 mg), testosterone (250 mg) or placebo intramuscularly every 2 weeks for 12 weeks. Fat-free mass, weight, immune markers and perception of treatment were the main outcome measures. Results Treatment with nandrolone resulted in significantly greater increases in fat-free mass [mean increase 1.34 kg; 95% confidence interval (CI) 0.60; 2.08 kg] and in weight (mean increase 1.48 kg; 95% CI 0.82; 2.14 kg) compared with placebo. The mean increase in weight with nandrolone of 1.00 kg (95% CI 0.27; 1.74 kg) when compared with testosterone was significant, although the difference in fat free mass did not reach significance (mean increase 0.69 kg; 95% CI-0.13; 1.51 kg). Patient perception of benefit was significantly greater in the nandrolone group when compared with both the placebo and the testosterone groups. Conclusions Treatment with nandrolone decanoate increased body weight when compared with placebo and testosterone. Nandrolone decanoate treatment resulted in greater increases in fat-free mass than placebo and demonstrated a trend for a significant increase when compared with testosterone.
Kamalski, Digna M A; Vincent, Robert; Wegner, Inge; Bittermann, Arnold J N; Grolman, Wilko
2014-12-01
Comparing hearing results in patients with otosclerosis treated with laser-assisted stapedotomy using the 2-μm thulium laser or the CO2 laser. Prospective nonrandomized clinical study. In a tertiary referral center in France (Jean Causse Ear Clinic, Béziers), 208 primary stapedotomies were performed in 204 patients between March 2008 and November 2009. Sufficient follow-up data were available for 194 procedures. The fenestration in the footplate was made with the thulium laser in 98 procedures and with a flexible CO2 laser in 96 procedures. Preoperative and postoperative audiometric results were compared. Side effects, such as vertigo and tinnitus, were scored. Patients treated with the CO2 laser had better hearing outcome compared with those treated with the thulium laser at both 3 and 12 months of follow-up. At 3 months, the success of the surgery, defined as closure of the air-bone gap to within 10 dB, was 90.0% in the thulium group compared with 96.8% in the CO2 group. Bone conduction shift showed an overall deterioration of 1.6 dB (standard deviation, 6.9 dB) in the thulium group compared with an improvement of 1.3 dB (standard deviation, 4 dB) in the CO2 group. In the thulium group, there were four patients with sensorineural hearing loss (4.4%) and three with tinnitus (3.1%) compared with none in the CO2 group. Stapedotomy surgery performed with a fiber-delivered thulium laser resulted in a higher chance of inner ear damage measured by bone conduction shift compared with the use of a fiber-delivered CO2 laser. We advise not to use the thulium laser for stapedotomy.
Krueger, Samantha; Simioni, Julia; Griffith, Lauren E; Hutton, Eileen K
2018-01-01
This study sought to compare obstetrical outcomes for women with a cephalic presentation at birth resulting from successful external cephalic version (ECV) compared to those resulting from spontaneous cephalic version (SCV). Secondary analysis was performed on Early External Cephalic Version Trial data. A total of 931 study participants had breech presentations between 34 and 36 weeks' gestation and cephalic presentations at birth. The incidence of intrapartum interventions was compared between patients with successful ECV (557) and those with SCV (374). A generalized linear mixed model was used to determine ORs for our primary outcomes. Parity, maternal BMI, previous CS, and enrolment centre were controlled for in the analysis. No differences were found after ECV compared with SCV in the incidence of CS (96 of 557 and 76 of 374, respectively; adjusted OR [aOR] 0.89; 95% CI 0.63-1.26), instrumental birth (68 of 557 and 29 of 373, respectively; aOR 1.55; 95% CI 0.96-2.50), or normal vaginal birth (393 of 557 and 268 of 373, respectively; aOR 0.92; 95% CI 0.68-1.24). Multiparous women with successful ECV were half as likely to require a CS compared with those with SCV and no ECV (28 of 313 and 42 of 258, respectively; aOR 0.45; 95% CI 0.26-0.80). This is the first study to compare birth outcomes of breech pregnancies that convert to cephalic presentation by means of SCV with birth outcomes of breech pregnancies that have ECV. Women with a cephalic-presenting fetus at birth as a result of successful ECV are not at greater risk of obstetrical interventions at birth when compared with women with fetuses who spontaneously turn to a cephalic presentation in the third trimester. Copyright © 2018. Published by Elsevier Inc.
Ceol, M; Forino, M; Gambaro, G; Sauer, U; Schleicher, E D; D'Angelo, A; Anglani, F
2001-01-01
Gene expression can be examined with different techniques including ribonuclease protection assay (RPA), in situ hybridisation (ISH), and quantitative reverse transcription-polymerase chain reaction (RT/PCR). These methods differ considerably in their sensitivity and precision in detecting and quantifying low abundance mRNA. Although there is evidence that RT/PCR can be performed in a quantitative manner, the quantitative capacity of this method is generally underestimated. To demonstrate that the comparative kinetic RT/PCR strategy-which uses a housekeeping gene as internal standard-is a quantitative method to detect significant differences in mRNA levels between different samples, the inhibitory effect of heparin on phorbol 12-myristate 13-acetate (PMA)-induced-TGF-beta1 mRNA expression was evaluated by RT/PCR and RPA, the standard method of mRNA quantification, and the results were compared. The reproducibility of RT/PCR amplification was calculated by comparing the quantity of G3PDH and TGF-beta1 PCR products, generated during the exponential phases, estimated from two different RT/PCR (G3PDH, r = 0.968, P = 0.0000; TGF-beta1, r = 0.966, P = 0.0000). The quantitative capacity of comparative kinetic RT/PCR was demonstrated by comparing the results obtained from RPA and RT/PCR using linear regression analysis. Starting from the same RNA extraction, but using only 1% of the RNA for the RT/PCR compared to RPA, significant correlation was observed (r = 0.984, P = 0.0004). Moreover the morphometric analysis of ISH signal was applied for the semi-quantitative evaluation of the expression and localisation of TGF-beta1 mRNA in the entire cell population. Our results demonstrate the close similarity of the RT/PCR and RPA methods in giving quantitative information on mRNA expression and indicate the possibility to adopt the comparative kinetic RT/PCR as reliable quantitative method of mRNA analysis. Copyright 2001 Wiley-Liss, Inc.
Comparative Pessimism or Optimism: Depressed Mood, Risk-Taking, Social Utility and Desirability.
Milhabet, Isabelle; Le Barbenchon, Emmanuelle; Cambon, Laurent; Molina, Guylaine
2015-03-05
Comparative optimism can be defined as a self-serving, asymmetric judgment of the future. It is often thought to be beneficial and socially accepted, whereas comparative pessimism is correlated with depression and socially rejected. Our goal was to examine the social acceptance of comparative optimism and the social rejection of comparative pessimism in two dimensions of social judgment, social desirability and social utility, considering the attributions of dysphoria and risk-taking potential (studies 2 and 3) on outlooks on the future. In three experiments, the participants assessed either one (study 1) or several (studies 2 and 3) fictional targets in two dimensions, social utility and social desirability. Targets exhibiting comparatively optimistic or pessimistic outlooks on the future were presented as non-depressed, depressed, or neither (control condition) (study 1); non-depressed or depressed (study 2); and non-depressed or in control condition (study 3). Two significant results were obtained: (1) social rejection of comparative pessimism in the social desirability dimension, which can be explained by its depressive feature; and (2) comparative optimism was socially accepted on the social utility dimension, which can be explained by the perception that comparatively optimistic individuals are potential risk-takers.
CloVR-Comparative: automated, cloud-enabled comparative microbial genome sequence analysis pipeline.
Agrawal, Sonia; Arze, Cesar; Adkins, Ricky S; Crabtree, Jonathan; Riley, David; Vangala, Mahesh; Galens, Kevin; Fraser, Claire M; Tettelin, Hervé; White, Owen; Angiuoli, Samuel V; Mahurkar, Anup; Fricke, W Florian
2017-04-27
The benefit of increasing genomic sequence data to the scientific community depends on easy-to-use, scalable bioinformatics support. CloVR-Comparative combines commonly used bioinformatics tools into an intuitive, automated, and cloud-enabled analysis pipeline for comparative microbial genomics. CloVR-Comparative runs on annotated complete or draft genome sequences that are uploaded by the user or selected via a taxonomic tree-based user interface and downloaded from NCBI. CloVR-Comparative runs reference-free multiple whole-genome alignments to determine unique, shared and core coding sequences (CDSs) and single nucleotide polymorphisms (SNPs). Output includes short summary reports and detailed text-based results files, graphical visualizations (phylogenetic trees, circular figures), and a database file linked to the Sybil comparative genome browser. Data up- and download, pipeline configuration and monitoring, and access to Sybil are managed through CloVR-Comparative web interface. CloVR-Comparative and Sybil are distributed as part of the CloVR virtual appliance, which runs on local computers or the Amazon EC2 cloud. Representative datasets (e.g. 40 draft and complete Escherichia coli genomes) are processed in <36 h on a local desktop or at a cost of <$20 on EC2. CloVR-Comparative allows anybody with Internet access to run comparative genomics projects, while eliminating the need for on-site computational resources and expertise.
Oh, Chang Hyun; Shim, Yu Shik; Park, Hyeong-chun; Park, Chong Oon; Lee, Myoung Seok
2013-01-01
Objective There are few published studies which have documented psychopathological abnormalities in patients with of adolescent idiopathic scoliosis (AIS) The aim of this study was to evaluate the psychopathological influence of AIS in Korean 19-year-old males. Methods The authors compared the Korean military multiphasic personal inventory (KMPI) military profiles of 105 AIS cases (more than 10 degrees of Cobb's angle without surgical treatment) with the KMPI profiles of 108 normal controls. The AIS group was split depending on Cobb's angle to further evaluate this relation by the severity of AIS. Results A significantly decreased result on the faking-good response scale and an significantly increased result on the faking-bad response were observed in the AIS group compared to the control (p<0.012). The neurosis scale results, including anxiety, depression and somatization symptoms, were significantly increased in the AIS group compared to the control (p<0.010). The severity level of personality disorder and schizophrenia were also significantly increased in the AIS group (p<0.010). Differences in KMPI scale scores were not related to the severity of AIS. Conclusion Young males with AIS tend to have abnormal results on the multiphasic personal inventory test compared to normal volunteers, suggesting that AIS may be related to psychopathology in the young male group in Korea. Although these psychopathology in AIS were differently observed compared to normal controls, but not interfered with military life. Clinicians are recommended to pay attention the psychopathological traits of patients with AIS. PMID:23440382
Horst, K; Garving, C; Thometzki, T; Lichte, P; Knobe, M; Dienstknecht, T; Hofman, M; Pape, H-C
2017-04-01
The aim of this study was to address the inconsistency regarding the operative treatment of Rockwood type III acromioclavicular joint separation. We compared results after single- and double TightRope ® reduction with results after acromioclavicular transfixation via K-wires only and additional ligament augmentation in acute acromioclavicular (AC) joint separations graded Rockwood type III, and hypothesized that the TightRope ® technique leads to better clinical and radiological results. We conducted a retrospective clinical cohort study and included 42 consecutive patients (mean age 43 years [24-66]) diagnosed and operatively treated between 2004 and 2012 (mean follow-up was 54.6 months [15-118]). Specific shoulder scores as well as scores reflecting the patients' overall mental and physical health status were used. Radiological evaluation was also performed. The SF12 test revealed comparability between all subgroups. Specific shoulder tests and a visual analogue scale demonstrated comparable results. Radiographic measurements showed a significant reduction in the AC distance and CC distance after surgery in all subgroups. The early complication rate was 9.5% for all patients, while late complications occurred in 14.3% of all cases. Compared to the established methods, the operative TightRope ® procedures represent a safe alternative in Rockwood III injuries. All investigated techniques predominantly led to good and excellent clinical results in acute Rockwood type III AC joint instabilities. Avoidance of material removal and shorter hospital stays appear to speak in favour for the TightRope ® technique. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Stepniewski, W. Z.; Shinn, R. A.
1983-01-01
A detailed comparative insight into design and operational philosophies of Soviet vs. Western helicopters is provided. This is accomplished by examining conceptual approaches, productibility and maintainability, and weight trends/prediction methodology. Extensive use of Soviet methodology (Tishchenko) to various weight classes of helicopters is compared to the results of using Western based methodology.
Material Models for the Human Torso Finite Element Model
2018-04-04
material characterizations drawn from current literature. Biofidelity of the ARL torso was determined by comparing peak force, force-displacement, peak...Flesh simulation. The soft tissue mesh in the upper neck was highly distorted at 21.2 ms (right) compared to the original mesh (left...a realistic response with results comparable to physical experiments to support future efforts to evaluate BABT. 2. Methods 2.1 Review of
ERIC Educational Resources Information Center
Kim, Tae-Young
2010-01-01
This paper investigates Korean high school students' English learning motivation and attitudes. In this regard, the results of a 2002 study were compared with those of a 2006 study. Questionnaire data were obtained from a total of 1,037 high school students in a major city in South Korea, and the data were compared with those on the students'…
ERIC Educational Resources Information Center
Miranda, Monica Carolina; Sinnes, Elaine Girao; Pompeia, Sabine; Bueno, Orlando Francisco Amodeo
2008-01-01
Objective: The present study investigated the performance of Brazilian children in the Continuous Performance Test, CPT-II, and compared results to those of the norms obtained in the United States. Method: The U.S. norms were compared to those of a Brazilian sample composed of 6- to 11-year-olds separated into 4 age-groups (half boys) that…
Comparing the Development of Transversal Skills between Virtual and Physical Exchanges
ERIC Educational Resources Information Center
Van der Velden, Bart; Millner, Sophie; Van der Heijden, Casper
2016-01-01
This paper aims to compare the impact on the development of transversal skills, such as self-esteem, of virtual and physical exchanges. This is done by comparing the Europe on the Edge programme to the results of the Erasmus Impact Study. In doing so it fills the need that has been expressed in the telecollaboration field to study the impact of…
ERIC Educational Resources Information Center
Puhan, Gautam; Boughton, Keith A.; Kim, Sooyeon
2005-01-01
The study evaluated the comparability of two versions of a teacher certification test: a paper-and-pencil test (PPT) and computer-based test (CBT). Standardized mean difference (SMD) and differential item functioning (DIF) analyses were used as measures of comparability at the test and item levels, respectively. Results indicated that effect sizes…
Comparing Supply-Side Specifications in Models of Global Agriculture and the Food System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Sherman; van Meijl, Hans; Willenbockel, Dirk
This paper compares the theoretical specification of production and technical change across the partial equilibrium (PE) and computable general equilibrium (CGE) models of the global agricultural and food system included in the AgMIP model comparison study. The two modeling approaches have different theoretical underpinnings concerning the scope of economic activity they capture and how they represent technology and the behavior of supply and demand in markets. This paper focuses on their different specifications of technology and supply behavior, comparing their theoretical and empirical treatments. While the models differ widely in their specifications of technology, both within and between the PEmore » and CGE classes of models, we find that the theoretical responsiveness of supply to changes in prices can be similar, depending on parameter choices that define the behavior of supply functions over the domain of applicability defined by the common scenarios used in the AgMIP comparisons. In particular, we compare the theoretical specification of supply in CGE models with neoclassical production functions and PE models that focus on land and crop yields in agriculture. In practice, however, comparability of results given parameter choices is an empirical question, and the models differ in their sensitivity to variations in specification. To illustrate the issues, sensitivity analysis is done with one global CGE model, MAGNET, to indicate how the results vary with different specification of technical change, and how they compare with the results from PE models.« less
Breast volume assessment: comparing five different techniques.
Bulstrode, N; Bellamy, E; Shrotria, S
2001-04-01
Breast volume assessment is not routinely performed pre-operatively because as yet there is no accepted technique. There have been a variety of methods published, but this is the first study to compare these techniques. We compared volume measurements obtained from mammograms (previously compared to mastectomy specimens) with estimates of volume obtained from four other techniques: thermoplastic moulding, magnetic resonance imaging, Archimedes principle and anatomical measurements. We also assessed the acceptability of each method to the patient. Measurements were performed on 10 women, which produced results for 20 breasts. We were able to calculate regression lines between volume measurements obtained from mammography to the other four methods: (1) magnetic resonance imaging (MRI), 379+(0.75 MRI) [r=0.48], (2) Thermoplastic moulding, 132+(1.46 Thermoplastic moulding) [r=0.82], (3) Anatomical measurements, 168+(1.55 Anatomical measurements) [r=0.83]. (4) Archimedes principle, 359+(0.6 Archimedes principle) [r=0.61] all units in cc. The regression curves for the different techniques are variable and it is difficult to reliably compare results. A standard method of volume measurement should be used when comparing volumes before and after intervention or between individual patients, and it is unreliable to compare volume measurements using different methods. Calculating the breast volume from mammography has previously been compared to mastectomy samples and shown to be reasonably accurate. However we feel thermoplastic moulding shows promise and should be further investigated as it gives not only a volume assessment but a three-dimensional impression of the breast shape, which may be valuable in assessing cosmesis following breast-conserving-surgery.
Empirical evidence of the importance of comparative studies of diagnostic test accuracy.
Takwoingi, Yemisi; Leeflang, Mariska M G; Deeks, Jonathan J
2013-04-02
Systematic reviews that "compare" the accuracy of 2 or more tests often include different sets of studies for each test. To investigate the availability of direct comparative studies of test accuracy and to assess whether summary estimates of accuracy differ between meta-analyses of noncomparative and comparative studies. Systematic reviews in any language from the Database of Abstracts of Reviews of Effects and the Cochrane Database of Systematic Reviews from 1994 to October 2012. 1 of 2 assessors selected reviews that evaluated at least 2 tests and identified meta-analyses that included both noncomparative studies and comparative studies. 1 of 3 assessors extracted data about review and study characteristics and test performance. 248 reviews compared test accuracy; of the 6915 studies, 2113 (31%) were comparative. Thirty-six reviews (with 52 meta-analyses) had adequate studies to compare results of noncomparative and comparative studies by using a hierarchical summary receiver-operating characteristic meta-regression model for each test comparison. In 10 meta-analyses, noncomparative studies ranked tests in the opposite order of comparative studies. A total of 25 meta-analyses showed more than a 2-fold discrepancy in the relative diagnostic odds ratio between noncomparative and comparative studies. Differences in accuracy estimates between noncomparative and comparative studies were greater than expected by chance (P < 0.001). A paucity of comparative studies limited exploration of direction in bias. Evidence derived from noncomparative studies often differs from that derived from comparative studies. Robustly designed studies in which all patients receive all tests or are randomly assigned to receive one or other of the tests should be more routinely undertaken and are preferred for evidence to guide test selection. National Institute for Health Research (United Kingdom).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stallmann, F.W.
1984-08-01
A statistical analysis of Charpy test results of the two-year Pressure Vessel Simulation metallurgical irradiation experiment was performed. Determination of transition temperature and upper shelf energy derived from computer fits compare well with eyeball fits. Uncertainties for all results can be obtained with computer fits. The results were compared with predictions in Regulatory Guide 1.99 and other irradiation damage models.
[Comparative research on the NIR and MIR micro-imaging of two similar plastic materials].
Wang, Dong; Ma, Zhi-Hong; Zhao, Liu; Pan, Li-Gang; Li, Xiao-Ting; Wang, Ji-Hua
2011-09-01
The NIR/MIR micro-imaging can supply not only the information of spectra, but also the information of spacial distribution of the sample, which is superior to the traditional NIR/MIR spectroscopy analysis. In the present paper, polyethylene and parafilm, with similar appearances, were regarded as the research objects, of which the NIR/MIR micro-imaging was collected. Chemical imaging (CI) and compare correlation imaging were carried out for the two materials respectively to discuss the imaging methods of the two materials. The result indicated that the differentiation of the CI values of the two materials in the NIR/MIR CI for material II was 0.004 8 and 0.254 8 respectively, while those in the NIR/MIR CI for material I were 0.002 6 and 0.326 5, respectively. Clear CI was acquired, and the two materials could be differentiated. The result of the compare correlation imagings indicated that the compare correlation imagings, in which the NIR/MIR spectra of the two materials were regarded as reference spectra respectively, can differentiate the two materials remarkably with clear imagings. In the compare correlation imagings of MIR micro-imaging, the difference of the correlation coefficients between the two materials' MIR spectra and the reference spectrum was more than 0.12, which showed a better imaging result; while a tiny difference of the correlation coefficients between the two materials' NIR spectra and the reference spectrum could be employed to show a clear imaging result for NIR compare correlation imaging so as to differentiate the two materials. This thesis, to some extent, can supply the reference to not only the rapid discrimination of the safety of the packaging material for agri-food, but also the imaging methods for NIR/MIR micro-imaging to differentiate the different materials.
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2017-10-01
The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.
Brigo, Francesco; Bragazzi, Nicola; Nardone, Raffaele; Trinka, Eugen
2016-11-01
The aim of this study was to conduct a meta-analysis of published studies to directly compare intravenous (IV) levetiracetam (LEV) with IV phenytoin (PHT) or IV valproate (VPA) as second-line treatment of status epilepticus (SE), to indirectly compare intravenous IV LEV with IV VPA using common reference-based indirect comparison meta-analysis, and to verify whether results of indirect comparisons are consistent with results of head-to-head randomized controlled trials (RCTs) directly comparing IV LEV with IV VPA. Random-effects Mantel-Haenszel meta-analyses to obtain odds ratios (ORs) for efficacy and safety of LEV versus VPA and LEV or VPA versus PHT were used. Adjusted indirect comparisons between LEV and VPA were used. Two RCTs comparing LEV with PHT (144 episodes of SE) and 3 RCTs comparing VPA with PHT (227 episodes of SE) were included. Direct comparisons showed no difference in clinical seizure cessation, neither between VPA and PHT (OR: 1.07; 95% CI: 0.57 to 2.03) nor between LEV and PHT (OR: 1.18; 95% CI: 0.50 to 2.79). Indirect comparisons showed no difference between LEV and VPA for clinical seizure cessation (OR: 1.16; 95% CI: 0.45 to 2.97). Results of indirect comparisons are consistent with results of a recent RCT directly comparing LEV with VPA. The absence of a statistically significant difference in direct and indirect comparisons is due to the lack of sufficient statistical power to detect a difference. Conducting a RCT that has not enough people to detect a clinically important difference or to estimate an effect with sufficient precision can be regarded a waste of time and resources and may raise several ethical concerns, especially in RCT on SE. Copyright © 2016 Elsevier Inc. All rights reserved.
Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A
2014-03-01
Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.
McCain, Stephanie L; Flatland, Bente; Schumacher, Juergen P; Clarke Iii, Elsburgh O; Fry, Michael M
2010-12-01
Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended. ©2010 American Society for Veterinary Clinical Pathology.
Depth optimal sorting networks resistant to k passive faults
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piotrow, M.
In this paper, we study the problem of constructing a sorting network that is tolerant to faults and whose running time (i.e. depth) is as small as possible. We consider the scenario of worst-case comparator faults and follow the model of passive comparator failure proposed by Yao and Yao, in which a faulty comparator outputs directly its inputs without comparison. Our main result is the first construction of an N-input, k-fault-tolerant sorting network that is of an asymptotically optimal depth {theta}(log N+k). That improves over the recent result of Leighton and Ma, whose network is of depth O(log N +more » k log log N/log k). Actually, we present a fault-tolerant correction network that can be added after any N-input sorting network to correct its output in the presence of at most k faulty comparators. Since the depth of the network is O(log N + k) and the constants hidden behind the {open_quotes}O{close_quotes} notation are not big, the construction can be of practical use. Developing the techniques necessary to show the main result, we construct a fault-tolerant network for the insertion problem. As a by-product, we get an N-input, O(log N)-depth INSERT-network that is tolerant to random faults, thereby answering a question posed by Ma in his PhD thesis. The results are based on a new notion of constant delay comparator networks, that is, networks in which each register is used (compared) only in a period of time of a constant length. Copies of such networks can be put one after another with only a constant increase in depth per copy.« less
[Comparative study of three series of neuro-cutaneous flaps used for coverage of leg defects].
Jecan, C R; Alecu, L; Costan, I S
2011-01-01
The purpose of the trial was to compare three groups of neurocutaneous flaps used to cover defects in the calf, in terms of preoperative characteristics and postoperative results. The main objective was to evaluate the effectiveness of surgical method by testing the hypothesis: neurocutaneous flaps can be applied with clinical results comparable to other surgical methods. The results were presented in the text, through graphic figures and tables. Statistical comparisons were performed according to the results obtained from three series of neurocutaneous flaps in terms of demographic characteristics and those describing postoperative results. The results obtained in the three types of flaps were compared with studies published by other authors, confirming the working hypothesis. The most important results are: the neurocutaneous sural flap is a distal pedicled flap with increased vascular resistance; age and co-morbidities may influence the degree of immediate complications but not the final success rate; the covered defect surface (p = 0.035) is higher for the sural and saphenous flap; the number of days of hospitalization is significantly lower than for microsurgical transfer flaps (p = 0.022). The frequency of complications and reintervention rates were similar (p = 0.022). The study concludes that the sural neurocutaneous flap can be used to cover defects of up to 200 cm2 in the calf with similar results to those of microsurgical transfer flaps.
Results of a simulator test comparing two display concepts for piloted flight-path-angle control
NASA Technical Reports Server (NTRS)
Kelley, W. W.
1978-01-01
Results of a simulator experiment which was conducted in order to compare pilot gamma-control performance using two display formats are reported. Pilots flew a variable flight path angle tracking task in the landing configuration. Pilot and airplane performance parameters were recorded and pilot comments noted for each case.
Laser-Beam-Alignment Controller
NASA Technical Reports Server (NTRS)
Krasowski, M. J.; Dickens, D. E.
1995-01-01
In laser-beam-alignment controller, images from video camera compared to reference patterns by fuzzy-logic pattern comparator. Results processed by fuzzy-logic microcontroller, which sends control signals to motor driver adjusting lens and pinhole in spatial filter.
NASA Astrophysics Data System (ADS)
Dube, B.; Lefebvre, S.; Perocheau, A.; Nakra, H. L.
1988-01-01
This paper describes the comparative results obtained from digital and hybrid simulation studies on a variable speed wind generator interconnected to the utility grid. The wind generator is a vertical-axis Darrieus type coupled to a synchronous machine by a gear-box; the synchronous machine is connected to the AC utility grid through a static frequency converter. Digital simulation results have been obtained using CSMP software; these results are compared with those obtained from a real-time hybrid simulator that in turn uses a part of the IREQ HVDC simulator. The agreement between hybrid and digital simulation results is generally good. The results demonstrate that the digital simulation reproduces the dynamic behavior of the system in a satisfactory manner and thus constitutes a valid tool for the design of the control systems of the wind generator.
Modeling of Nitrogen Oxides Emissions from CFB Combustion
NASA Astrophysics Data System (ADS)
Kallio, S.; Keinonen, M.
In this work, a simplified description of combustion and nitrogen oxides chemistry was implemented in a 1.5D model framework with the aim to compare the results with ones earlier obtained with a detailed reaction scheme. The simplified chemistry was written using 12 chemical components. Heterogeneous chemistry is given by the same models as in the earlier work but the homogeneous and catalytic reactions have been altered. The models have been taken from the literature. The paper describes the numerical model with emphasis on the chemistry submodels. A simulation of combustion of bituminous coal in the Chalmers 12 MW boiler is conducted and the results are compared with the results obtained earlier with the detailed chemistry description. The results are also compared with measured O2, CO, NO and N2O profiles. The simplified reaction scheme produces equally good results as earlier obtained with the more elaborate chemistry description.
Phonation offset in tracheoesophageal speech.
Searl, Jeff; Ousley, Teri
2004-01-01
Tracheoesophageal (TE) speakers often have difficulty producing the voiced-voiceless distinction. Phonation offset (POff) as a TE speaker transitions from a vowel to a stop consonant may be altered, possibly contributing to listener misperceptions. The purposes of this study were to: (1) compare the duration of POff in TE versus laryngeal speakers, and (2) compare POff between TE productions that were accurately versus inaccurately perceived. Phonation offset and offset duration as a proportion of the stop gap (%POff) were greater for the TE versus the laryngeal samples. There was no difference in POff or %POff when comparing accurately to inaccurately perceived TE samples. Tracheoesophageal speakers may have less ability to halt neoglottal vibration compared to laryngeal speakers' ability to stop glottal vibration. Comparable POff for accurately and inaccurately perceived TE samples suggests that POff may not be a particularly salient acoustic feature to the voicing distinction, at least for stop consonants. (1) As a result of this activity, participants will be able to describe what phonation offset is relative to the voicing distinction. (2) As a result of this activity, participants will be able to describe phonation offset in tracheoesophageal speakers relative to laryngeal speakers. (3) As a result of this activity, participants will be able to describe whether phonation offset in tracheoesophageal speech has perceptual saliency for listeners.
Experimental characterization of the AFIT neutron facility. Master's thesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lessard, O.J.
1993-09-01
AFIT's Neutron Facility was characterized for room-return neutrons using a (252)Cf source and a Bonner sphere spectrometer with three experimental models, the shadow shield, the Eisenhauer, Schwartz, and Johnson (ESJ), and the polynomial models. The free-field fluences at one meter from the ESJ and polynomial models were compared to the equivalent value from the accepted experimental shadow shield model to determine the suitability of the models in the AFIT facility. The polynomial model behaved erratically, as expected, while the ESJ model compared to within 4.8% of the shadow shield model results for the four Bonner sphere calibration. The ratio ofmore » total fluence to free-field fluence at one meter for the ESJ model was then compared to the equivalent ratio obtained by a Monte Cario Neutron-Photon transport code (MCNP), an accepted computational model. The ESJ model compared to within 6.2% of the MCNP results. AFIT's fluence ratios were compared to equivalent ratios reported by three other neutron facilities which verified that AFIT's results fit previously published trends based on room volumes. The ESJ model appeared adequate for health physics applications and was chosen was chosen for calibration of the AFIT facility. Neutron Detector, Bonner Sphere, Neutron Dosimetry, Room Characterization.« less
Karimian, Farid; Zarei-Ghanavati, Siamak; A, Baradaran-Rafii; Jadidi, Khosrow; Lotfi-Kian, Alireza
2011-06-01
To evaluate the microbiological characteristics of eyelid margin flora in chronic blepharitis in mustard gas-exposed individuals and compare the results with those in age- and sex-matched unexposed people. In this comparative case series, 289 patients with ocular manifestations of mustard gas exposure (case) were evaluated for signs of chronic blepharitis. Additionally, microbiological evaluation of eyelid margins was conducted in these patients and compared with results of 100 unexposed patients with chronic blepharitis (control). One-hundred fifty (52.0%) of 289 mustard gas casualties had signs of chronic blepharitis. Microbiological evaluation revealed higher isolation rates of Staphylococcus epidermidis (78%) and Staphylococcus aureus (57%) in the case in comparison to control group (P < 0.01). Moreover, S. aureus isolated from the cases exhibited greater resistance to common antibiotics compared with control group. Fungi were isolated more frequent in the case compared with controls (30% vs. 4%, P < 0.01), with Cladosporium and Candida species being most common in the case group. Exposure to mustard gas seems to alter the microbiological flora of the eyelid margin. Staphylococcus spp., including antibiotic-resistant strains, and fungi were more frequently isolated in these patients. The relationship between microbial culture results and the severity of ocular surface manifestations in mustard gas-injured cases warrant further investigation.
Relatively certain! Comparative thinking reduces uncertainty.
Mussweiler, Thomas; Posten, Ann-Christin
2012-02-01
Comparison is one of the most ubiquitous and versatile mechanisms in human information processing. Previous research demonstrates that one consequence of comparative thinking is increased judgmental efficiency: comparison allows for quicker judgments without a loss in accuracy. We hypothesised that a second potential consequence of comparative thinking is reduced judgmental uncertainty. We examined this possibility in three experiments using three different domains of judgment and three different measures of uncertainty. Results consistently demonstrate that procedurally priming participants to rely more heavily on comparative thinking during judgment induces them to feel more certain about their judgment. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agrawal, Ashish; Barth, Michael; Madan, Himanshu
2014-08-04
Compressively strained InSb (s-InSb) and Ge (s-Ge) quantum well heterostructures are experimentally studied, with emphasis on understanding and comparing hole transport in these two-dimensional confined heterostructures. Magnetotransport measurements and bandstructure calculations indicate 2.5× lower effective mass for s-InSb compared to s-Ge quantum well at 1.9 × 10{sup 12} cm{sup –2}. Advantage of strain-induced m* reduction is negated by higher phonon scattering, degrading hole transport at room temperature in s-InSb quantum well compared to s-Ge heterostructure. Consequently, effective injection velocity is superior in s-Ge compared to s-InSb. These results suggest s-Ge quantum well heterostructure is more favorable and promising p-channel candidate compared to s-InSbmore » for future technology node.« less
[Attitudes towards psychotherapy in South Korea and Germany : A cross-cultural comparative study].
Schulz, W; Shin, M A; Schmid-Ott, G
2018-01-01
Due to the relatively recent introduction of psychotherapy in South Korea and against the background of collectivist and Confucian values, it has been suggested that South Koreans harbor more negative attitudes towards psychotherapy compared to Germans and that the social acceptance of psychotherapy is lower. We compared the attitudes of 99 women from South Korea with 98 German women using the questionnaire on attitudes towards psychotherapeutic treatment (FEP). For the study of the South Korean women we translated the questionnaire into the Korean language. The results of the psychometric analysis suggest that the Korean version of the FEP is of acceptable quality. South Korean women reported a significantly more negative attitude towards psychotherapy compared to German women. Furthermore, South Korean women anticipated a more skeptical social attitude towards psychotherapy compared to Germans. The presented results suggest the relevance of cultural imprinting in psychotherapy. They are discussed with respect to culture-specific self-concepts, concepts of disease and healing expectations and the increase of individualistic values in the Korean society.
Jang, Seung I; Lillehoj, Hyun S; Lee, Sung-Hyen; Lee, Kyung Woo; Lillehoj, Erik P; Hong, Yeong Ho; An, Dong-Jun; Jeoung, D Hye-Young; Chun, Ji-Eun
2013-09-01
Necrotic enteritis is an enteric disease of poultry resulting from infection by Clostridium perfringens with coinfection by Eimeria spp. constituting a major risk factor for disease pathogenesis. This study compared three commercial broiler chicken lines using an experimental model of necrotic enteritis. Day-old male Cobb, Ross, and Hubbard broilers were orally infected with viable C. perfringens and E. maxima and fed a high-protein diet to promote the development of experimental disease. Body weight loss, intestinal lesions, and serum antibody levels against alpha-toxin and necrotic enteritis B-like (NetB) toxin were measured as parameters of disease susceptibility and host immune response. Cobb chickens exhibited increased body weight loss compared with Ross and Hubbard breeds and greater gut lesion severity compared with Ross chickens. NetB antibody levels were greater in Cobb chickens compared with the Ross or Hubbard groups. These results suggest that Cobb chickens may be more susceptible to necrotic enteritis in the field compared with the Ross and Hubbard lines.
La Barbera, Luigi; Galbusera, Fabio; Wilke, Hans-Joachim; Villa, Tomaso
2016-09-01
To discuss whether the available standard methods for preclinical evaluation of posterior spine stabilization devices can represent basic everyday life activities and how to compare the results obtained with different procedures. A comparative finite element study compared ASTM F1717 and ISO 12189 standards to validated instrumented L2-L4 segments undergoing standing, upper body flexion and extension. The internal loads on the spinal rod and the maximum stress on the implant are analysed. ISO recommended anterior support stiffness and force allow for reproducing bending moments measured in vivo on an instrumented physiological segment during upper body flexion. Despite the significance of ASTM model from an engineering point of view, the overly conservative vertebrectomy model represents an unrealistic worst case scenario. A method is proposed to determine the load to apply on assemblies with different anterior support stiffnesses to guarantee a comparable bending moment and reproduce specific everyday life activities. The study increases our awareness on the use of the current standards to achieve meaningful results easy to compare and interpret.
Harmonic Scalpel Versus Electrocautery in Axillary Dissection in Carcinoma Breast.
Nawaz, Allah; Waqar, Sadaf; Khan, Ahsan; Mansoor, Rashid; Butt, Usman Ismat; Ayyaz, Mahmood
2015-12-01
To compare the results between harmonics scalpel and electrocautery use in axillary dissection for carcinoma breast. Randomized controlled trial. Department of Surgery, Services Hospital, Lahore, from December 2013 to June 2014. Eighty patients fulfilling the inclusion criteria were selected and equally divided in two groups. Axillary dissection for carcinoma breast was performed by using the harmonic scalpel in one group and by using electrocautery in the other group. Total mean axillary drain output and frequency of axillary numbness were noted in both groups and compared. All the patients were females with mean age of 53.52 ± 9.8. Mean axillary drain output in harmonic scalpel group was 167.75 ± 43.90 as compared to 310.00 ± 60.09 in electrocautery group while only 12.5% of patients were positive for axillary numbness in harmonic scalpel group as compared to 100% of patients who were positive for electrocautery group. Use of harmonic scalpel in axillary dissection resulted in decreased total mean axillary drain output and lowered frequency of axillary numbness when compared to utilizing electrocautery.
Nutritional Differences between Two Orangutan Habitats: Implications for Population Density.
Vogel, Erin R; Harrison, Mark E; Zulfa, Astri; Bransford, Timothy D; Alavi, Shauhin E; Husson, Simon; Morrogh-Bernard, Helen; Santiano; Firtsman, Twentinolosa; Utami-Atmoko, Sri Suci; van Noordwijk, Maria A; Farida, Wartika Rosa
2015-01-01
Bottom-up regulatory factors have been proposed to exert a strong influence on mammalian population density. Studies relating habitat quality to population density have typically made comparisons among distant species or communities without considering variation in food quality among localities. We compared dietary nutritional quality of two Bornean orangutan populations with differing population densities in peatland habitats, Tuanan and Sabangau, separated by 63 km. We hypothesized that because Tuanan is alluvial, the plant species included in the orangutan diet would be of higher nutritional quality compared to Sabangau, resulting in higher daily caloric intake in Tuanan. We also predicted that forest productivity would be greater in Tuanan compared to Sabangau. In support of these hypotheses, the overall quality of the diet and the quality of matched dietary items were higher in Tuanan, resulting in higher daily caloric intake compared to Sabangau. These differences in dietary nutritional quality may provide insights into why orangutan population density is almost two times greater in Tuanan compared to Sabangau, in agreement with a potentially important influence of diet quality on primate population density.
Jain, Priyanka; Arora, Neha; Mehtani, Juhi; Pruthi, Vikas; Majumder, C B
2017-10-01
In the present investigation, toxic algal bloom, a copious and low-cost nutrient source was deployed for cultivating Chlorella pyrenoidosa. Various pre-treatment methods using combinations of acid/alkali and autoclave/microwave were tested for preparing hydrolysates and compared with minimal media (BG-11). Acid autoclave treatment resulted in maximum carbon, nitrogen and phosphorous content which substantially boosted the growth of the microalgal cells (4.36g/L) as compared to rest of the media. The microalga grown in this media also showed enhanced lipid content (43.2%) and lipid productivity (188mg/L/d) as compared to BG-11 (19.42mg/L/d). The biochemical composition showed 1.6-fold declines in protein while 1.27 folds in carbohydrate content as compared to BG-11. The fatty acid profile revealed the presence of C14-C22 with increased amount of monounsaturated fatty acids as compared to BG-11. The results obtained showed that algal bloom can be used as a potential nutrient source for microalgae. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nutritional Differences between Two Orangutan Habitats: Implications for Population Density
Vogel, Erin R.; Harrison, Mark E.; Zulfa, Astri; Bransford, Timothy D.; Alavi, Shauhin E.; Husson, Simon; Morrogh-Bernard, Helen; Santiano; Firtsman, Twentinolosa; Utami-Atmoko, Sri Suci; van Noordwijk, Maria A.; Farida, Wartika Rosa
2015-01-01
Bottom-up regulatory factors have been proposed to exert a strong influence on mammalian population density. Studies relating habitat quality to population density have typically made comparisons among distant species or communities without considering variation in food quality among localities. We compared dietary nutritional quality of two Bornean orangutan populations with differing population densities in peatland habitats, Tuanan and Sabangau, separated by 63 km. We hypothesized that because Tuanan is alluvial, the plant species included in the orangutan diet would be of higher nutritional quality compared to Sabangau, resulting in higher daily caloric intake in Tuanan. We also predicted that forest productivity would be greater in Tuanan compared to Sabangau. In support of these hypotheses, the overall quality of the diet and the quality of matched dietary items were higher in Tuanan, resulting in higher daily caloric intake compared to Sabangau. These differences in dietary nutritional quality may provide insights into why orangutan population density is almost two times greater in Tuanan compared to Sabangau, in agreement with a potentially important influence of diet quality on primate population density. PMID:26466370
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, M.E.
1997-12-05
This V and V Report includes analysis of two revisions of the DMS [data management system] System Requirements Specification (SRS) and the Preliminary System Design Document (PSDD); the source code for the DMS Communication Module (DMSCOM) messages; the source code for selected DMS Screens, and the code for the BWAS Simulator. BDM Federal analysts used a series of matrices to: compare the requirements in the System Requirements Specification (SRS) to the specifications found in the System Design Document (SDD), to ensure the design supports the business functions, compare the discreet parts of the SDD with each other, to ensure thatmore » the design is consistent and cohesive, compare the source code of the DMS Communication Module with the specifications, to ensure that the resultant messages will support the design, compare the source code of selected screens to the specifications to ensure that resultant system screens will support the design, compare the source code of the BWAS simulator with the requirements to interface with DMS messages and data transfers relating to the BWAS operations.« less
ERIC Educational Resources Information Center
Ginsburg, Golda S.; Becker, Kimberly D.; Drazdowski, Tess K.; Tein, Jenn-Yun
2012-01-01
Background: The effectiveness of cognitive-behavioral treatment (CBT) in inner city schools, when delivered by novice CBT clinicians, and compared to usual care (UC), is unknown. Objective: This pilot study addressed this issue by comparing a modular CBT for anxiety disorders to UC in a sample of 32 volunteer youth (mean age 10.28 years, 63%…
Computer Aided Deflection Measurement of an Aircraft Wing.
1987-09-01
force the wing to oscillate at a given frequency and compare the output characteristics to the inputs. This second method allows for more extensive tests...34 ’ .:. ... :.: ..-. ’ . .... ? .? ’ * .". . . ".. . % .. " . ,-..,...-.. . " compare the resulting output oscillations to the input forces. This would...the wing’s performance when new and provide a measuring point against which future tests can be compared after the aircraft has been in service. While
Ng, Leo; Rosalie, Simon M; Sherry, Dorianne; Loh, Wei Bing; Sjurseth, Andreas M; Iyengar, Shrikant; Wild, Catherine Y
2018-03-01
Research has revealed that field hockey drag flickers have greater odds of hip and lumbar injuries compared to non-drag flickers (DF). This study aimed to compare the biomechanics of a field hockey hit and a specialised field hockey drag flick. Eighteen male and seven female specialised hockey DF performed a hit and a drag flick in a motion analysis laboratory with an 18-camera three-dimensional motion analysis system and a calibrated multichannel force platform to examine differences in lower limb and lumbar kinematics and kinetics. Results revealed that drag flicks were performed with more of a forward lunge on the left lower limb resulting in significantly greater left ankle dorsiflexion, knee, hip and lumbar flexion (Ps<0.001) compared to a hit. Drag flicks were also performed with significantly greater lateral flexion (P < 0.002) and rotation of the lumbar spine (P < 0.006) compared to a hit. Differences in kinematics lead to greater shear, compression and tensile forces in multiple left lower limb and lumbar joints in the drag flick compared to the hit (P < 0.05). The biomechanical differences in drag flicks compared to a hit may have ramifications with respect to injury in field hockey drag flickers.
Prevalence and Risk Factors for Hypertension in Hemophilia
von Drygalski, Annette; Kolaitis, Nicholas A; Bettencourt, Ricki; Bergstrom, Jaclyn; Kruse-Jarres, R; Quon, Doris VK; Wassel, Christina; Li, Ming C; Waalen, Jill; Elias, Darlene J; Mosnier, Laurent O; Allison, Matthew
2013-01-01
Hypertension is a major risk factor for intracranial hemorrhage. We therefore investigated the prevalence, treatment and control of hypertension in adult patients with hemophilia (PWH). PWH ≥18 years (n=458) from 3 geographically different cohorts in the United States were evaluated retrospectively for hypertension and risk factors. Results were compared to the nationally representative sample provided by the contemporary National Health and Nutrition Examination Survey (NHANES). PWH had a significantly higher prevalence of hypertension compared to NHANES. Overall, the prevalence of hypertension was 49.1% in PWH compared to 31.7 % in NHANES. At ages 18–44, 45–64, 65–74, and ≥ 75 the prevalence of hypertension for PWH was 31.8%, 72.6%, 89.7%, and 100.0% compared to 12.5%, 41.2%, 64.1%, and 71.7% in NHANES, respectively. Of treated hypertensive PWH, only 27.1% were controlled, compared to 47.7% in NHANES (all p-values <0.05). Age, body mass index, diabetes and renal function were independently associated with hypertension. Among patients with moderate or severe hemophilia there was a trend (~ 1.5-fold) for higher odds of having hypertension compared to patients with mild hemophilia. Based on these results, new care models for adult PWH and further studies for the etiology of hypertension in hemophilia are recommended. PMID:23630949
Laser stapedotomy: a comparative study of prostheses and seals.
Perkins, R; Curto, F S
1992-12-01
During the past 13 years, a number of prostheses of differing design and tissue seals have been used in laser stapedotomy for otosclerosis. This study compares the results of three different configurations of prostheses and tissue seals in a series of 53 patients. In 19, a platinum wire Teflon piston was placed in the laser stapedotomy fenestra and crimped on the long process of the incus; autologous venous blood was infiltrated into the oval window niche as a sealing mechanism. In 8 patients, a stainless steel bucket-handle-type prosthesis was used with a blood tissue seal. In 26 patients, a segment of autogenous vein was clad onto the bucket-handle-type prosthesis and placed into the laser fenestra. Two tissue seals (blood and vein) were also compared. The results were compared with regard to several audiometric parameters. It would appear that the bucket handle/vein configuration improves air-bone gap closure in the low- and mid-frequency speech range and also shows an advantage for air-bone gap closure to 10 dB or less compared to the other configurations in this study. Mean postoperative gaps were significantly less for vein compared to the blood tissue seal. Physiologic and surgical implications are discussed, and the vein-clad technique is illustrated.
Dosimetry for a uterine cervix cancer treatment
NASA Astrophysics Data System (ADS)
Rodríguez-Ponce, Miguel; Rodríguez-Villafuerte, Mercedes; Sánchez-Castro, Ricardo
2003-09-01
The dose distribution around the 3M 137Cs brachytherapy source as well as the same source inside the Amersham ASN 8231 applicator was measured using thermoluminescent dosimeters and radiochromic films. Some of the results were compared with those obtained from a Monte Carlo simulation and a good agreement was observed. The teletherapy dose distribution was measured using a pin-point ionization chamber. In addition, the experimental measurements and the Monte Carlo results were used to estimate the dose received in the rectum and bladder of an hypothetical patient treated with brachytherapy and compared with the dose distribution obtained from the Hospital's brachytherapy planning system. A 20 % dose reduction to the rectum and bladder was observed in both Monte Carlo and experimental measurements, compared with the results of the planning system, which results in a better dose control to these structures.
Single electron impact ionization of the methane molecule
NASA Astrophysics Data System (ADS)
Bouamoud, Mammar; Sahlaoui, Mohammed; Benmansour, Nour El Houda; Atomic and Molecular Collisions Team
2014-10-01
Triply differential cross sections (TDCS) results of electron-impact ionization of the inner 2a1 molecular orbital of CH4 are presented in the framework of the Second Born Approximation and compared with the experimental data performed in coplanar asymmetric geometry. The cross sections are averaged on the random orientations of the molecular target for accurate comparison with experiments and are compared also with the theoretical calculations of the Three Coulomb wave (3CW) model. Our results are in good agreement with experiments and 3CW results in the binary peak. In contrast the Second Born Approximation yields a significant higher values compared to the 3CW results for the recoil peak and seems to describe suitably the recoil region where higher order effects can occur with the participation of the recoiling ion in the collision process.
Parametric and experimental analysis using a power flow approach
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1990-01-01
A structural power flow approach for the analysis of structure-borne transmission of vibrations is used to analyze the influence of structural parameters on transmitted power. The parametric analysis is also performed using the Statistical Energy Analysis approach and the results are compared with those obtained using the power flow approach. The advantages of structural power flow analysis are demonstrated by comparing the type of results that are obtained by the two analytical methods. Also, to demonstrate that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental study of structural power flow is presented. This experimental study presents results for an L shaped beam for which an available solution was already obtained. Various methods to measure vibrational power flow are compared to study their advantages and disadvantages.
Bhandari, Mohit; Tornetta, Paul; Ellis, Thomas; Audige, Laurent; Sprague, Sheila; Kuo, Jonathann C; Swiontkowski, Marc F
2004-01-01
There have been a number of non-randomized studies comparing arthroplasty with internal fixation in patients with femoral neck fractures. However, there remains considerable debate about whether the results of non-randomized studies are consistent with the results of randomized, controlled trials. Given the economic burden of hip fractures, it remains essential to identify therapies to improve outcomes; however, whether data from non-randomized studies of an intervention should be used to guide patient care remains unclear. We aimed to determine whether the pooled results of mortality and revision surgery among non-randomized studies were similar to those of randomized trials in studies comparing arthroplasty with internal fixation in patients with femoral neck fractures. We conducted a Medline search from 1969 to June 2002, identifying both randomized and non-randomized studies comparing internal fixation with arthroplasty in patients with femoral neck fractures. Additional strategies to identify relevant articles included Cochrane database, SCISEARCH, textbooks, annual meeting programs, and content experts. We abstracted information on mortality and revision rates in each study and compared the pooled results between non-randomized and randomized studies. In addition, we explored potential reasons for dissimilar results between the two study designs. We identified 140 citations that addressed the general topic of comparison of arthroplasty and internal fixation for hip fracture. Of these, 27 studies met the eligibility criteria, 13 of which were non-randomized studies and 14 of which were randomized trials. Mortality data was available in all 13 non-randomized studies ( n=3108 patients) and in 12 randomized studies ( n=1767 patients). Non-randomized studies overestimated the risk of mortality by 40% when compared with the results of randomized trials (relative risk 1.44 vs 1.04, respectively). Information on revision risk was available in 9 non-randomized studies ( n=2764 patients) and all 14 randomized studies ( n=1901 patients). Both estimates from non-randomized and randomized studies revealed a significant reduction in the risk of revision surgery with arthroplasty compared with internal fixation (relative risk 0.38 vs 0.23, respectively). The reduction in the risk of revision surgery with arthroplasty compared with internal fixation was 62% for non-randomized studies and 77% for randomized trials. Thus, non-randomized studies underestimated the relative benefit of arthroplasty by 19.5%. Non-randomized studies with point estimates of relative risk similar to the pooled estimate for randomized trials all controlled for patient age, gender, and fracture displacement in their comparisons of mortality. We were unable to identify reasons for differences in the revision rate results between the study designs. Similar to other reports in medical subspecialties, non-randomized studies provided results dissimilar to randomized trials of arthroplasty vs internal fixation for mortality and revision rates in patients with femoral neck fractures. Investigators should be aware of these discrepancies when evaluating the merits of alternative surgical interventions, especially when both randomized trials and non-randomized comparative studies are available.
Pappas, Evangelos
2007-01-01
The incidence of injury in combat sports has not been adequately reported although it is important to identify the nature and frequency of injuries prior to the implementation of prevention programs. This study compared injury rates treated in Hospital Emergency Departments between different combat sports of boxing, wrestling, and martial arts. A secondary objective described anatomic region and diagnosis of these injuries. Data were obtained on all boxing, wrestling, and martial arts-related injuries that were in the National Electronic Injury Surveillance System database and resulted in Emergency Department visits between 2002 and 2005. Pearson's chi-square statistics were calculated to compare injury rates for each activity accounting for complex sample design. Martial arts had lower injury rates compared to boxing and wrestling for all diagnoses (p<0.001). Boxing had lower injury rates compared to wrestling for strains/sprains and dislocations. Boxing and wrestling had similar injury rates for concussions. Injury prevention efforts should consider the distribution of injuries and concentrate on preventing strains/sprains in wrestling, concussions in boxing and wrestling, and fractures for all three activities. The findings of the present study do not provide evidence that combat sports have alarmingly high rates of injuries resulting in emergency department visits. Key pointsMartial arts have lower emergency department injury rates compared to boxing and wrestling.Wrestling has higher strains/sprains and dislocation injury rates compared to boxing.Combat sports do not appear to have higher injury rates compared to non-combat sports.
Morbidity and chronic pain following different techniques of caesarean section: A comparative study.
Belci, D; Di Renzo, G C; Stark, M; Đurić, J; Zoričić, D; Belci, M; Peteh, L L
2015-01-01
Research examining long-term outcomes after childbirth performed with different techniques of caesarean section have been limited and do not provide information on morbidity and neuropathic pain. The study compares two groups of patients submitted to the 'Traditional' method using Pfannenstiel incision and patients submitted to the 'Misgav Ladach' method ≥ 5 years after the operation. We find better long-term postoperative results in the patients that were treated with the Misgav Ladach method compared with the Traditional method. The results were statistically better regarding the intensity of pain, presence of neuropathic and chronic pain and the level of satisfaction about cosmetic appearance of the scar.
Enea, Violeta; Dafinoiu, Ion; Bogdan, Georgiana; Matei, Carmen
2017-07-01
Most of the studies concerning nonsuicidal self-injury behaviors of persons deprived of liberty were on female participants. This cross-sectional comparative study compared the levels of death anxiety, pain catastrophizing, dissociative experiences, and state-trait anger among male inmates with nonsuicidal self-injury behaviors and noninjuring controls. The results indicated high levels of death anxiety, dissociation, and pain catastrophizing in both groups of participants and the absence of significant differences between the groups. The implications of the results suggest the need of taking into consideration these variables in the behavior management plans used with inmates who engage in self-injurious behavior.
Nonlinear disturbance observer based sliding mode control of a cable-driven rehabilitation robot.
Niu, Jie; Yang, Qianqian; Chen, Guangtao; Song, Rong
2017-07-01
This paper introduces a cable-driven robot for upper-limb rehabilitation. Kinematic and dynamic of this rehabilitation robot is analyzed. A sliding mode controller combined with a nonlinear disturbance observer is proposed to control this robot in the presence of disturbances. Simulation is carried out to prove the effectiveness of the proposed control scheme, and the results of the proposed controller is compared with a PID controller and a traditional sliding mode controller. Results show that the proposed controller can effectively improve the tracking performance as compared with the other two controllers and cause lower chattering as compared with a traditional sliding mode controller.
Biases in comparative analyses of extinction risk: mind the gap.
González-Suárez, Manuela; Lucas, Pablo M; Revilla, Eloy
2012-11-01
1. Comparative analyses are used to address the key question of what makes a species more prone to extinction by exploring the links between vulnerability and intrinsic species' traits and/or extrinsic factors. This approach requires comprehensive species data but information is rarely available for all species of interest. As a result comparative analyses often rely on subsets of relatively few species that are assumed to be representative samples of the overall studied group. 2. Our study challenges this assumption and quantifies the taxonomic, spatial, and data type biases associated with the quantity of data available for 5415 mammalian species using the freely available life-history database PanTHERIA. 3. Moreover, we explore how existing biases influence results of comparative analyses of extinction risk by using subsets of data that attempt to correct for detected biases. In particular, we focus on links between four species' traits commonly linked to vulnerability (distribution range area, adult body mass, population density and gestation length) and conduct univariate and multivariate analyses to understand how biases affect model predictions. 4. Our results show important biases in data availability with c.22% of mammals completely lacking data. Missing data, which appear to be not missing at random, occur frequently in all traits (14-99% of cases missing). Data availability is explained by intrinsic traits, with larger mammals occupying bigger range areas being the best studied. Importantly, we find that existing biases affect the results of comparative analyses by overestimating the risk of extinction and changing which traits are identified as important predictors. 5. Our results raise concerns over our ability to draw general conclusions regarding what makes a species more prone to extinction. Missing data represent a prevalent problem in comparative analyses, and unfortunately, because data are not missing at random, conventional approaches to fill data gaps, are not valid or present important challenges. These results show the importance of making appropriate inferences from comparative analyses by focusing on the subset of species for which data are available. Ultimately, addressing the data bias problem requires greater investment in data collection and dissemination, as well as the development of methodological approaches to effectively correct existing biases. © 2012 The Authors. Journal of Animal Ecology © 2012 British Ecological Society.
Outcomes and cost comparisons after introducing a robotics program for endometrial cancer surgery.
Lau, Susie; Vaknin, Zvi; Ramana-Kumar, Agnihotram V; Halliday, Darron; Franco, Eduardo L; Gotlieb, Walter H
2012-04-01
To evaluate the effect of introducing a robotic program on cost and patient outcome. This was a prospective evaluation of clinical outcome and cost after introducing a robotics program for the treatment of endometrial cancer and a retrospective comparison to the entire historical cohort. Consecutive patients with endometrial cancer who underwent robotic surgery (n=143) were compared with all consecutive patients who underwent surgery (n=160) before robotics. The rate of minimally invasive surgery increased from 17% performed by laparoscopy to 98% performed by robotics in 2 years. The patient characteristics were comparable in both eras, except for a higher body mass index in the robotics era (median 29.8 compared with 27.6; P<.005). Patients undergoing robotics had longer operating times (233 compared with 206 minutes), but fewer adverse events (13% compared with 42%; P<.001), lower estimated median blood loss (50 compared with 200 mL; P<.001), and shorter median hospital stay (1 compared with 5 days; P<.001). The overall hospital costs were significantly lower for robotics compared with the historical group (Can$7,644 compared with Can$10,368 [Canadian dollars]; P<.001) even when acquisition and maintenance cost were included (Can$8,370 compared with Can$10,368; P=.001). Within 2 years after surgery, the short-term recurrence rate appeared lower in the robotics group compared with the historic cohort (11 recurrences compared with 19 recurrences; P<.001). Introduction of robotics for endometrial cancer surgery increased the proportion of patients benefitting from minimally invasive surgery, improved short-term outcomes, and resulted in lower hospital costs. II.
A framework for understanding cancer comparative effectiveness research data needs
Carpenter, William R; Meyer, Anne-Marie; Abernethy, Amy P.; Stürmer, Til; Kosorok, Michael R.
2012-01-01
Objective Randomized controlled trials remain the gold standard for evaluating cancer intervention efficacy. Randomized trials are not always feasible, practical, or timely, and often don’t adequately reflect patient heterogeneity and real-world clinical practice. Comparative effectiveness research can leverage secondary data to help fill knowledge gaps randomized trials leave unaddressed; however, comparative effectiveness research also faces shortcomings. The goal of this project was to develop a new model and inform an evolving framework articulating cancer comparative effectiveness research data needs. Study Design and Setting We examined prevalent models and conducted semi-structured discussions with 76 clinicians and comparative effectiveness research researchers affiliated with the Agency for Healthcare Research and Quality’s cancer comparative effectiveness research programs. Results A new model was iteratively developed, and presents cancer comparative effectiveness research and important measures in a patient-centered, longitudinal chronic care model better-reflecting contemporary cancer care in the context of the cancer care continuum, rather than a single-episode, acute-care perspective. Conclusion Immediately relevant for federally-funded comparative effectiveness research programs, the model informs an evolving framework articulating cancer comparative effectiveness research data needs, including evolutionary enhancements to registries and epidemiologic research data systems. We discuss elements of contemporary clinical practice, methodology improvements, and related needs affecting comparative effectiveness research’s ability to yield findings clinicians, policymakers, and stakeholders can confidently act on. PMID:23017633
Siegrist, Michael; Orlow, Pascale; Keller, Carmen
2008-01-01
To evaluate various formats for the communication of prenatal test results. In study 1 (N=400), female students completed a questionnaire assessing risk perception, affect, and perceived usefulness of prenatal test results. A randomized, 2 (risk level; low, high) x 4 (format; ratio with numerator 1, ratio with denominator 1000, Paling Perspective Scale, pictograms) design was used. Study 2 (N=200) employed a 2 (risk level; low, high) x 2 (format; Paling Perspective Scale, risk comparisons in numerical format) design. In study 1, the Paling Perspective Scale resulted in a higher level of perceived risk across different risk levels compared with the other formats. Furthermore, participants in the low-risk group perceived the test results as less risky compared with participants in the high-risk group (P < 0.001) when the Paling Perspective Scale was used. No significant differences between low and high risks were observed for the other 3 formats. In study 2, the Paling Perspective Scale evoked higher levels of perceived risks relative to the numerical presentation of risk comparisons. For both formats, we found that participants confronted with a high risk perceived test results as more risky compared with participants confronted with a low risk. The Paling Perspective Scale resulted in a higher level of perceived risk compared with the other formats. This effect must be taken into account when choosing a graphical or numerical format for risk communication.
Bacterial Cr(VI) reduction concurrently improves sunflower (Helianthus Annuus L.) growth.
Faisal, Muhammad; Hasnain, Shahida
2005-07-01
Four Cr(VI)-reducing bacterial strains (Ochrobactrum intermedium, CrT-2, CrT-3 and CrT-4) previously isolated from chromium-contaminated sites were inoculated on to seeds of sunflower (Helianthus annuus var SF-187), which were germinated and grown along with non-inoculated controls with chromate salts (300 microg CrCl3 or K2CrO4 ml(-1)). Severe reduction (20%) in seed germination was observed in Cr(VI) stress. Plant height decreased (36%) with Cr(VI) when compared with chromium-free control, while O. intermedium inoculation resulted a 20% increment in this parameter as compared to non-inoculated chromium-free control. CrT-3 inoculation resulted a 69% increment in auxin content as compared to non-inoculated control. O. intermedium caused 30% decrease in chromium uptake in sunflower plant roots under Cr(VI) stress as compared to chromium-free control plants.
Analysis of a Chevron Beam Thermal Actuator
NASA Astrophysics Data System (ADS)
Joshi, Amey Sanjay; Mohammed, Hussain; Kulkarni, S. M., Dr.
2018-02-01
Thermal MEMS (Micro-Electro-Mechanical Systems) actuators and sensors have a wide range of applications. The chevron type thermal actuators comparatively show superior performance over other existing electrostatic and thermal actuators. This paper describes the design and analysis of chevron type thermal actuator. Here standard design of Chevron type thermal actuator is considered which comprises of proof mass at center and array of six beams of a uniform cross section of 3 3 microns and an initial angle of 5°. The thermal actuator was designed and analyzed using analytical and finite element method and the results were compared. The model was also analyzed for initial angles of 2.5° and 7.5°, and the results were compared with FEA model. The cross section of the beam was varied and the finite element analysis of all three models was compared to suggest the best suitable thermal actuator structure.
Barrel maturation, oak alternatives and micro-oxygenation: influence on red wine aging and quality.
Oberholster, A; Elmendorf, B L; Lerno, L A; King, E S; Heymann, H; Brenneman, C E; Boulton, R B
2015-04-15
The impact of micro-oxygenation (MOX) in conjunction with a variety of oak alternatives on phenolic composition and red wine aging was investigated and compared with traditional barrel aging. Although several studies concluded that MOX give similar results to barrel aging, few have compared them directly and none directly compared MOX with and without wood alternatives and barrel aging. Results confirmed that MOX had a positive effect on colour density, even after 5 months of bottle aging. This is supported by an increase in polymeric phenol and pigment content not only with aging but in the MOX compared to barrel matured wine treatments. Descriptive analysis showed that MOX in combination with wood alternatives such as oak chips and staves could mimic short term (six months) barrel aging in new American and French oak barrels in regards to sensory characteristics. Published by Elsevier Ltd.
Altruism revisited: a comparison of medical, law and business students' altruistic attitudes.
Coulter, Ian D; Wilkes, Michael; Der-Martirosian, Claudia
2007-04-01
Although the concept of altruism in medicine has a long tradition in Western thought, little empirical research has been carried out recently in this area. This study compares the altruistic attitudes of medical, legal and business students. We used a cross-sectional survey to compare the altruistic attitudes of 3 types of contemporary 'professional' students, those in medicine, law and business. The results suggest that medical students report more altruistic attitudes than legal students, but not than business students. Overall, female students reported stronger attitudes consistent with altruism compared with males; African-American and Hispanic students reported more altruistic attitudes compared with White students. Our results suggest that the recent trend in recruiting more women and under-represented minority group members into medicine may have a positive impact on altruism in the profession, if we can assume that attitudes correlate with behaviours.
[Laservaporization of the prostate: current status of the greenlight and diode laser].
Rieken, M; Bachmann, A; Gratzke, C
2013-03-01
In the last decade laser vaporization of the prostate has emerged as a safe and effective alternative to transurethral resection of the prostate (TURP). This was facilitated in particular by the introduction of photoselective vaporization of the prostate (PVP) with a 532 nm 80 W KTP laser in 2002. Prospective randomized trials comparing PVP and TURP with a maximum follow-up of 3 years mostly demonstrated comparable functional results. Cohort studies showed a safe application of PVP in patients under oral anticoagulation and with large prostates. Systems from various manufacturers with different maximum power output and wavelengths are now available for diode laser vaporization of the prostate. Prospective randomized trials comparing diode lasers and TURP are not yet available. In cohort studies and comparative studies PVP diode lasers are characterized by excellent hemostatic properties but functional results vary greatly with some studies reporting high reoperation rates.
Evaluating the Changing Financial Burdens for Graduating Pharmacists
Ulbrich, Timothy R.
2017-01-01
Objective. To compare new practitioners in 2009 and 2014 by modeling net income from available salary, expenditure, and student loan data. Methods. A Monte Carlo simulation with probabilistic sensitivity analysis was conducted to model net income for graduating pharmacists in 2009 and 2014. Mean and standard deviations were recorded for each model parameter. Student t-tests were used to compare the mean differences between 2009 and 2014 cohorts. Results. Pharmacist salary and disposable income were higher on average in 2014 compared with 2009. Consumer expenditures were higher in 2014, offsetting the higher salary resulting in a 2014 discretionary income that was less than in 2009 [95% CI: -$2,336, -$1,587]. Net income decreased from 2009 to 2014 for all pharmacy school types. Conclusion. Regardless of loan payment strategy, net incomes for pharmacists graduating from public and private institutions were less in 2014 compared with 2009. PMID:29109563
Evaluating the Changing Financial Burdens for Graduating Pharmacists.
Mattingly, T Joseph; Ulbrich, Timothy R
2017-09-01
Objective. To compare new practitioners in 2009 and 2014 by modeling net income from available salary, expenditure, and student loan data. Methods. A Monte Carlo simulation with probabilistic sensitivity analysis was conducted to model net income for graduating pharmacists in 2009 and 2014. Mean and standard deviations were recorded for each model parameter. Student t -tests were used to compare the mean differences between 2009 and 2014 cohorts. Results. Pharmacist salary and disposable income were higher on average in 2014 compared with 2009. Consumer expenditures were higher in 2014, offsetting the higher salary resulting in a 2014 discretionary income that was less than in 2009 [95% CI: -$2,336, -$1,587]. Net income decreased from 2009 to 2014 for all pharmacy school types. Conclusion. Regardless of loan payment strategy, net incomes for pharmacists graduating from public and private institutions were less in 2014 compared with 2009.
Experimental rotordynamic coefficient results for honeycomb seals
NASA Technical Reports Server (NTRS)
Elrod, David A.; Childs, Dara W.
1988-01-01
Test results (leakage and rotordynamic coefficients) are presented for seven honeycomb-stator smooth-rotor seals. Tests were carried out with air at rotor speeds up to 16,000 cpm and supply pressures up to 8.2 bars. Test results for the seven seals are compared, and the most stable configuration is identified based on the whirl frequency ratio. Results from tests of a smooth-rotor/smooth-stator seal, a teeth-on-stator labyrinth seal, and the most stable honeycomb seal are compared.
Andriolo, Luca; Merli, Giulia; Tobar, Carlos; Altamura, Sante Alessandro; Kon, Elizaveta; Filardo, Giuseppe
2018-02-06
The aim of this study was to document the available evidence on the use of regenerative techniques for the treatment of femoral head osteonecrosis (or avascular necrosis of femoral head, AVN) and to understand their benefit compared to core decompression (CD) alone in avoiding failure and the need for total hip replacement (THR). The search was conducted on three medical electronic databases according to PRISMA guidelines. The studies reporting number and timing of failures were included in a meta-analysis calculating cumulative survivorship with a Kaplan-Mayer curve. Moreover, the results on failures in treatment groups reported in RCT were compared with those documented in control groups, in order to understand the benefit of biological therapies compared to CD for the treatment of AVN. Forty-eight studies were included in this systematic review, reporting results of different types of regenerative techniques: mesenchymal stem cell implantation in the osteonecrotic area, intra-arterial infiltration with mesenchymal stem cells, implantation of bioactive molecules, or platelet-rich plasma. Overall, reported results were good, with a cumulative survivorship of 80% after ten year follow-up, and better results when regenerative treatments were combined to CD compared to CD alone (89.9% vs 70.6%, p < 0.0001). Regenerative therapies offer good clinical results for the treatment of AVN. The combination of CD with regenerative techniques provides a significant improvement in terms of survivorship over time compared with CD alone. Further studies are needed to identify the best procedure and the most suitable patients to benefit from regenerative treatments for AVN.
Stiles, Mitchell F; Campbell, Leanne R; Jin, Tao; Graff, Donald W; Fant, Reginald V; Henningfield, Jack E
2018-05-03
We previously reported that following a short-term product use period, use of non-menthol Vuse Solo electronic cigarettes (ECs) resulted in product effect-related subjective responses and nicotine uptake between those of combustible cigarettes (high-abuse liability comparator) and nicotine gum (low-abuse liability comparator); the results were generally closer to those of nicotine gum. Using a similar design to the previous study, we evaluated the abuse liability of three menthol-flavored Vuse Solo ECs with the same nicotine contents (14, 29, and 36 mg) in a group of EC-naïve, menthol cigarette smokers, relative to comparator products. Six-hour nicotine uptake and ratings of subjective effects were used to determine abuse liability and pharmacokinetics. Use of menthol Vuse Solo resulted in significantly lower responses to subjective measurements (product liking, intent to use product again, and liking of positive product effects), higher urge to smoke responses, and a lower peak (C max ) and overall extent (AUC 0-360 ) of nicotine uptake compared to smoking the usual brand menthol cigarette. When compared with use of nicotine gum, subjective responses to use of menthol Vuse ECs were in the same direction as those resulting from smoking cigarettes but were more similar to nicotine gum use in magnitude than they were to cigarettes. These findings are concordant with our previous results and provide evidence that menthol Vuse Solo ECs have abuse liability that is lower than menthol cigarettes and potentially greater than that of nicotine gum. ClinicalTrials.gov identifier: NCT02664012.
Molaee, Neda; Abtahi, Hamid; Ghannadzadeh, Mohammad Javad; Karimi, Masoude; Ghaznavi-Rad, Ehsanollah
2015-01-01
Polymerase chain reaction (PCR) is preferred to other methods for detecting Escherichia coli (E. coli) in water in terms of speed, accuracy and efficiency. False positive result is considered as the major disadvantages of PCR. For this reason, reverse transcriptase-polymerase chain reaction (RT-PCR) can be used to solve this problem. The aim of present study was to determine the efficiency of RT-PCR for rapid detection of viable Escherichia coli in drinking water samples and enhance its sensitivity through application of different filter membranes. Specific primers were designed for 16S rRNA and elongation Factor II genes. Different concentrations of bacteria were passed through FHLP and HAWP filters. Then, RT-PCR was performed using 16srRNA and EF -Tu primers. Contamination of 10 wells was determined by RT-PCR in Arak city. To evaluate RT-PCR efficiency, the results were compared with most probable number (MPN) method. RT-PCR is able to detect bacteria in different concentrations. Application of EF II primers reduced false positive results compared to 16S rRNA primers. The FHLP hydrophobic filters have higher ability to absorb bacteria compared with HAWB hydrophilic filters. So the use of hydrophobic filters will increase the sensitivity of RT-PCR. RT-PCR shows a higher sensitivity compared to conventional water contamination detection method. Unlike PCR, RT-PCR does not lead to false positive results. The use of EF-Tu primers can reduce the incidence of false positive results. Furthermore, hydrophobic filters have a higher ability to absorb bacteria compared to hydrophilic filters.
Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.
2014-01-01
Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643
Williams, D S Blaise; Green, Douglas H; Wurzinger, Brian
2012-10-01
Both forefoot strike shod (FFS) and barefoot (BF) running styles result in different mechanics when compared to rearfoot strike (RFS) shod running. Additionally, running mechanics of FFS and BF running are similar to one another. Comparing the mechanical changes occurring in each of these patterns is necessary to understand potential benefits and risks of these running styles. The authors hypothesized that FFS and BF conditions would result in increased sagittal plane joint angles at initial contact and that FFS and BF conditions would demonstrate a shift in sagittal plane joint power from the knee to the ankle when compared to the RFS condition. Finally, total lower extremity power absorption will be least in BF and greatest in the RFS shod condition. The study included 10 male and 10 female RFS runners who completed 3-dimensional running analysis in 3 conditions: shod with RFS, shod with FFS, and BF. Variables were the angles of plantarflexion, knee flexion, and hip flexion at initial contact and peak sagittal plane joint power at the hip, knee, and ankle during stance phase. Running with a FFS pattern and BF resulted in significantly greater plantarflexion and significantly less negative knee power (absorption) when compared to shod RFS condition. FFS condition runners landed in the most plantarflexion and demonstrated the most peak ankle power absorption and lowest knee power absorption between the 3 conditions. BF and FFS conditions demonstrated decreased total lower extremity power absorption compared to the shod RFS condition but did not differ from one another. BF and FFS running result in reduced total lower extremity power, hip power and knee power and a shift of power absorption from the knee to the ankle. Alterations associated with BF running patterns are present in a FFS pattern when wearing shoes. Additionally, both patterns result in increased demand at the foot and ankle as compared to the knee.
Pelzer, Alexandre E; Heinzelbecker, Julia; Weiß, Christel; Frühbauer, Dominik; Weidner, Anja M; Kirchner, Matthias; Stroebel, Philipp; Schoenberg, Stephan O; Dinter, Dietmar J
2013-05-01
To compare the results of RTE with four different modalities at 3.0 T using endorectal and body phased array coil in the detection of PC. Between May 2009 and July 2010, 50 patients with biopsy proven PC scheduled for radical prostatectomy (RP) were examined. All patients underwent RTE of the prostate and 3.0 T endorectal MRI. The investigators were unaware of the clinical data and of each others results. RTE detected PC in 46 (92%) and MRI in 42 (84%) of the patients. Depending on the analysis sensitivity was 44.1-58.9% for RTE and 36.7-43.1% for MRI. Specificity was 83.0-74.8% for RTE and 85.9-79.8% for MRI. Sensitivity was significantly higher for RTE (16-sectors: p=0.0348; 8-sectors: p=0.0002) and showed better results in the dorsal (RTE: 51.9%; MRT: 37.7%) and apical to middle (RTE: 66.7%-80.0%; MRI: 41.7%-60.0%) parts of the prostate. MRI showed better results in the base (MRI: 19.4%; RTE: 14.9%) and transitional zone (TZ) (MRI: 34.7%; RTE: 29.6%). Concerning capsular involvement the results were comparable with sensitivity and specificity of RTE being 79.2% and 80.0% compared to 80.8% and 70.0% of MRI. Concerning sensitivity RTE showed advantages in apical and middle parts whereas MRI may provide advantages in the glands' base and TZ. Both RTE and MRI have limitations particularly in basal and ventral parts. Most of the undetected tumours were of low tumour volume and Gleason Score. Considering capsular involvement both techniques showed comparable results. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Comparability of river suspended-sediment sampling and laboratory analysis methods
Groten, Joel T.; Johnson, Gregory D.
2018-03-06
Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.
Gordon, N. C.; Wareham, D. W.
2009-01-01
CHROMagar Acinetobacter was used to screen stool and perineal swabs for enteric carriage of multidrug-resistant Acinetobacter baumannii in samples from critically ill patients. Results were compared with a molecular assay resulting in sensitivity and specificity of culture compared to PCR of 91.7% and 89.6%, respectively. PMID:19439546
Sport fishing: a comparison of three indirect methods for estimating benefits.
Darrell L. Hueth; Elizabeth J. Strong; Roger D. Fight
1988-01-01
Three market-based methods for estimating values of sport fishing were compared by using a common data base. The three approaches were the travel-cost method, the hedonic travel-cost method, and the household-production method. A theoretical comparison of the resulting values showed that the results were not fully comparable in several ways. The comparison of empirical...
Investigating the use of small-diameter softwood as guardrail posts: static test results
David E. Kretschmann; Ron Faller; Jason Hascall; John Reid; Dean Sicking; John Rohde; Dick Shilts; Tim Nelson
2007-01-01
Round guardrail posts may provide an important value added option for small-diameter thinnings. Such posts require minimum processing and have been shown to have higher strength compared to the equivalent rectangular volume. The resulting value-added product may bring a higher return compared to lumber. The obstacles to immediate utilization of ponderosa pine and...
ERIC Educational Resources Information Center
Mady, Callie
2014-01-01
This paper presents the results of a study that compared the French as a second official achievement of three groups of students: (1) Canadian-born English speaking (CBE), (2) Canadian-born multilingual (CBM), and (3) immigrant multilinguals (IMM) as determined by multiskills test results. ANOVAs and subsequent post hoc tests revealed that the…
Comparing Two Examination Results Using Means of Sample Means and Control Charts
ERIC Educational Resources Information Center
Alabi-Labaika, A. Bisi; Ahani, E.
2015-01-01
Some examination candidates submit their scripts first, sometimes, for recognition as being brilliant, and some do for not knowing what to write. However, some equally submit last because they want to dot i's and cross t's. The objective of this research is to compare the results of both the earliest and latest submissions with the aim of finding…
ERIC Educational Resources Information Center
Sepp, Anu; Ruokonen, Inkeri; Ruismäki, Heikki
2015-01-01
This article reveals the results of a comparative study of Estonian and Finnish general music education. The aim was to find out what music teaching practices and approaches/methods were mostly used, what music education perspectives supported those practices. The data were collected using questionnaires and the results of 107 Estonian and 50…
ERIC Educational Resources Information Center
Tsai, Tsung-Lung; Li, Hui-Chuan
2017-01-01
Over the past few decades, researchers, policy makers, educators and the general public, who have an interest in mathematics education in different countries, pay a great deal of attention to the results from international comparative studies. Of great interest to the international studies is the results of Eastern students consistently achieving…
Comparison of vacuum and gravity sap flows from paired sugar maple trees
H. Clay Smith; Carter B. Gibbs
1970-01-01
Paired sugar maple trees with single tapholes were used to compare sap yields from vacuum-pumping with sap yields from gravity flow. Results indicated that vacuum yields were approximately twice as great as gravity flows. These results support previous findings from studies in which vacuum and gravity were compared with two tapholes on the same tree.
[The kidney transplantation from the ABO-incompatible donors].
Goriaĭnov, V A; Kaabak, M M; Babenko, N N; Shishlo, L A; Morozova, M M; Ragimov, A A; Dashkova, N G; Salimov, É L
2012-01-01
The experience of 28 allotransplantations of ABO-incompatible kidneys was compared with the treatment results of 38 ABO-compatible renal transplantations. The transplanted kidney function, morphological changes of the transplanted kidney and the comparative analysis of actuary survival in both groups showed no significant difference. The results of the study prove the validity of the kidney transplantation from the ABO-incompatible donors.
Siegle, Cristhina Bonilha Huster; Dos Santos Cardoso de Sá, Cristina
2018-02-01
Exposure to HIV during pregnancy is a risks to development. Exposed child should have assessed its development since birth. Alberta Infant Motor Scale is a tool which assess gross motor skills, with easy application and low cost. Up to now, this scale had not proven its validity for the population exposed to HIV. It's necessary to compare its with a gold standard tool, Bayley scale, which assess gross and fine motor skills, has a high cost and longer application time required. Studies compare results of Alberta with Bayley's total motor score (gross + fine). However, it's also necessary to compare Alberta's result with only Bayley's gross motor result, because it's what both evaluate in common. to verify the concurrent validity of AIMS in infants exposed to HIV; to verify the correlation of AIMS and BSITD III for this population and to compare if these coefficients differ in the central age groups and extremities of the AIMS. 82 infants exposed to HIV evaluated in 1st, 2nd, 3rd, 4th, 8th, 12th, 15th, 16th, 17th and 18th months, with Alberta Infant Motor Scale and Bayley Scale (motor subscale). For analysis of concurrent validity, results of raw scores of the scales were compared with the correlation analysis. First analysis: Alberta's score with Bayley's total (gross + fine) motor score. Second analysis: Alberta's score with Bayley's gross motor score. In the first correlation analysis, results were: r = 0.62 in 1 st month, r = 0.64 in 2nd month, r = 0.08 in 3rd month, r = 0.45 in 4th month; r = 0.62 in 8th month, r = 0.60 in the 12th month. In the second correlation analysis, results were: r = 0.69 in 1 st month; r = 0.58 in 2nd month; r = 0.25 in 3rd month; r = 0.45 in the 4th month; r = 0.77 in 8th month; r = 0.73 in 12th month. Analyzes of the 15th, 16th, 17th and 18th months couldn't be performed because at these ages all the children had already reached the maximum score in the AIMS. Results were significant and indicate correlation between scales. Found results agree with other studies that found high correlations between the scales in premature and risk groups. However, these studies compare results of gross motor skills assessments with gross and fine motor skills assessments. Our results show that correlation only between the gross motor skills have higher coefficient values, and we believe this is the best way to compare the scales, with what both assessed in common. Alberta scale has correlation with Bayley scale in assessing of children exposed to HIV, and can be a substitute to Bayley in assessing of these children. Results are stronger when comparing only what both scales assess in common. Copyright © 2018 Elsevier Inc. All rights reserved.
Perceptions of Leadership: Comparing Canadian and Irish Physiotherapists' Views
McGowan, Emer; Martin, Gillian
2016-01-01
Purpose: To contribute to the growing body of research on leadership in physiotherapy by comparing leadership-related perceptions of physiotherapists in Ireland and in Canada. Methods: This article compares the results of a survey of Canadian physiotherapists with those of the same survey administered to Irish physiotherapists. The results of both studies have previously been reported and are used here to allow a cultural comparison of the perceptions of physiotherapists. The present study used two-portion Z-tests to compare the percentage of physiotherapists in Ireland who self-declared as a leader with the percentage of physiotherapists in Canada who did so. Results: Physiotherapists in both Ireland and Canada most often rated communication and professionalism as extremely important characteristics. Physiotherapists in Canada were more likely than those in Ireland to perceive themselves as leaders (Z=2.67, p < 0.05; 95% CI: 1.33, 9.87). Factors associated with self-declaration as a leader differed between the two countries. Conclusion: Physiotherapists in Canada and Ireland showed both similarities and differences in their perceptions of leadership characteristics. Results from this study may aid the development of future leadership training programmes specifically targeted at physiotherapists. PMID:27909357
IFCPT S-Duct Grid-Adapted FUN3D Computations for the Third Propulsion Aerodynamics Works
NASA Technical Reports Server (NTRS)
Davis, Zach S.; Park, M. A.
2017-01-01
Contributions of the unstructured Reynolds-averaged Navier-Stokes code, FUN3D, to the 3rd AIAA Propulsion Aerodynamics Workshop are described for the diffusing IFCPT S-Duct. Using workshop-supplied grids, results for the baseline S-Duct, baseline S-Duct with Aerodynamic Interface Plane (AIP) rake hardware, and baseline S-Duct with flow control devices are compared with experimental data and results computed with output-based, off-body grid adaptation in FUN3D. Due to the absence of influential geometry components, total pressure recovery is overpredicted on the baseline S-Duct and S-Duct with flow control vanes when compared to experimental values. An estimate for the exact value of total pressure recovery is derived for these cases given an infinitely refined mesh. When results from output-based mesh adaptation are compared with those computed on workshop-supplied grids, a considerable improvement in predicting total pressure recovery is observed. By including more representative geometry, output-based mesh adaptation compares very favorably with experimental data in terms of predicting the total pressure recovery cost-function; whereas, results computed using the workshop-supplied grids are underpredicted.
NASA Technical Reports Server (NTRS)
Bartels, Robert E.
2012-01-01
This paper presents the implementation of gust modeling capability in the CFD code FUN3D. The gust capability is verified by computing the response of an airfoil to a sharp edged gust. This result is compared with the theoretical result. The present simulations will be compared with other CFD gust simulations. This paper also serves as a users manual for FUN3D gust analyses using a variety of gust profiles. Finally, the development of an Auto-Regressive Moving-Average (ARMA) reduced order gust model using a gust with a Gaussian profile in the FUN3D code is presented. ARMA simulated results of a sequence of one-minus-cosine gusts is shown to compare well with the same gust profile computed with FUN3D. Proper Orthogonal Decomposition (POD) is combined with the ARMA modeling technique to predict the time varying pressure coefficient increment distribution due to a novel gust profile. The aeroelastic response of a pitch/plunge airfoil to a gust environment is computed with a reduced order model, and compared with a direct simulation of the system in the FUN3D code. The two results are found to agree very well.
NASA Astrophysics Data System (ADS)
Bialas, James; Oommen, Thomas; Rebbapragada, Umaa; Levin, Eugene
2016-07-01
Object-based approaches in the segmentation and classification of remotely sensed images yield more promising results compared to pixel-based approaches. However, the development of an object-based approach presents challenges in terms of algorithm selection and parameter tuning. Subjective methods are often used, but yield less than optimal results. Objective methods are warranted, especially for rapid deployment in time-sensitive applications, such as earthquake damage assessment. Herein, we used a systematic approach in evaluating object-based image segmentation and machine learning algorithms for the classification of earthquake damage in remotely sensed imagery. We tested a variety of algorithms and parameters on post-event aerial imagery for the 2011 earthquake in Christchurch, New Zealand. Results were compared against manually selected test cases representing different classes. In doing so, we can evaluate the effectiveness of the segmentation and classification of different classes and compare different levels of multistep image segmentations. Our classifier is compared against recent pixel-based and object-based classification studies for postevent imagery of earthquake damage. Our results show an improvement against both pixel-based and object-based methods for classifying earthquake damage in high resolution, post-event imagery.
An Assessment of Incentive Versus Survey Length Trade-offs in a Web Survey of Radiologists
Niederhauser, Blake D; Kallmes, David; Beebe, Timothy J
2013-01-01
Background It is generally understood that shorter Web surveys and use of incentives result in higher response rates in Web surveys directed to health care providers. Less is known about potential respondent preference for reduced burden as compared to increased reward. Objective To help elicit preference for minimized burden compared to reward for completion of a survey, we observed physician preferences for shorter Web surveys compared to incentives as well as incentive preference (small guaranteed incentive compared to larger lottery incentive) accompanying an electronic request to complete a survey. Methods This was an observational study that accompanied a large Web survey study of radiology staff, fellows, and residents at select academic medical centers in the United States. With the request to complete the survey, potential respondents were offered three options: (1) a 10-minute Web survey with the chance to win an iPad, (2) a 10-minute Web survey with a guaranteed nominal incentive ($5 amazon.com gift card), or (3) a shorter (5-7 minute) Web survey with no incentive. A total of 254 individuals responded to the Web survey request. Results Overwhelmingly, individuals chose a longer survey accompanied by an incentive compared to a shorter survey with no incentive (85% compared to 15%, P<.001). Of those opting for an incentive, a small, but not significant majority chose the chance to win an iPad over a guaranteed $5 gift card (56% compared to 44%). Conclusions When given the choice, radiologists preferred a reward (either guaranteed or based on a lottery) to a less burdensome survey, indicating that researchers should focus more attention at increasing perceived benefits of completing a Web survey compared to decreasing perceived burden. PMID:23514869
Wilson, Michele R; Bergman, Annika; Chevrou-Severac, Helene; Selby, Ross; Smyth, Michael; Kerrigan, Matthew C
2018-03-01
To examine the clinical and economic impact of vedolizumab compared with infliximab, adalimumab, and golimumab in the treatment of moderately to severely active ulcerative colitis (UC) in the United Kingdom (UK). A decision analytic model in Microsoft Excel was used to compare vedolizumab with other biologic treatments (infliximab, adalimumab, and golimumab) for the treatment of biologic-naïve patients with UC in the UK. Efficacy data were obtained from a network meta-analysis using placebo as the common comparator. Other inputs (e.g., unit costs, adverse-event disutilities, probability of surgery, mortality) were obtained from published literature. Costs were presented in 2012/2013 British pounds. Outcomes included quality-adjusted life-years (QALYs). Costs and outcomes were discounted by 3.5% per year. Incremental cost-effectiveness ratios were presented for vedolizumab compared with other biologics. Univariate and multivariate probabilistic sensitivity analyses were conducted to assess model robustness to parameter uncertainty. The model predicted that anti-tumour necrosis factor-naïve patients on vedolizumab would accrue more QALY than patients on other biologics. The incremental results suggest that vedolizumab is a cost-effective treatment compared with adalimumab (incremental cost-effectiveness ratio of £22,735/QALY) and dominant compared with infliximab and golimumab. Sensitivity analyses suggest that results are most sensitive to treatment response and transition probabilities. However, vedolizumab is cost-effective irrespective of variation in any of the input parameters. Our model predicted that treatment with vedolizumab improves QALY, increases time in remission and response, and is a cost-effective treatment option compared with all other biologics for biologic-naïve patients with moderately to severely active UC.
Briens, Mickaël; Mercier, Yves; Rouffineau, Friedrich; Vacchina, Veronique; Geraert, Pierre-André
2013-08-01
Two experiments were conducted on broiler chickens to compare the effect of a new organic Se source, 2-hydroxy-4-methylselenobutanoic acid (HMSeBA; SO), with two practical Se additives, sodium selenite (SS) and Se yeast (SY). The relative bioavailability of the different Se sources was compared on muscle (pectoralis major) total Se, selenomethionine (SeMet) and selenocysteine (SeCys) concentrations and apparent digestibility of total Se (ADSe). In the first experiment, from day (d) 0 to d21, Se sources were tested at different supplied levels and compared with an unsupplemented diet (NC). No significant effects were observed on growth performance during the experimental period. However, the different Se sources and levels improved muscle Se concentration compared with the NC, with a significant source effect in the following order: SS < SY < SO (P<0·05). Seleno-amino acids speciation results for NC, SY and SO at 0·3 mg Se/kg feed indicated that muscle Se was only present as SeMet or SeCys, showing a full conversion of Se by the bird. The second experiment (d0-d24) compared SS, SY or SO at 0·3 mg Se/kg feed. The ADSe measurements carried out between d20 and d23 were 24, 46 and 49% for SS, SY and SO, respectively, with significant differences between the organic and mineral Se sources (P<0·05). These results confirmed the higher bioavailability of organic Se sources compared with the mineral source and demonstrated a significantly better efficiency of HMSeBA compared with SY for muscle Se enrichment.
All-optical analog comparator.
Li, Pu; Yi, Xiaogang; Liu, Xianglian; Zhao, Dongliang; Zhao, Yongpeng; Wang, Yuncai
2016-08-23
An analog comparator is one of the core units in all-optical analog-to-digital conversion (AO-ADC) systems, which digitizes different amplitude levels into two levels of logical '1' or '0' by comparing with a defined decision threshold. Although various outstanding photonic ADC approaches have been reported, almost all of them necessitate an electrical comparator to carry out this binarization. The use of an electrical comparator is in contradiction to the aim of developing all-optical devices. In this work, we propose a new concept of an all-optical analog comparator and numerically demonstrate an implementation based on a quarter-wavelength-shifted distributed feedback laser diode (QWS DFB-LD) with multiple quantum well (MQW) structures. Our results show that the all-optical comparator is very well suited for true AO-ADCs, enabling the whole digital conversion from an analog optical signal (continuous-time signal or discrete pulse signal) to a binary representation totally in the optical domain. In particular, this all-optical analog comparator possesses a low threshold power (several mW), high extinction ratio (up to 40 dB), fast operation rate (of the order of tens of Gb/s) and a step-like transfer function.
Li, Pu; Yi, Xiaogang; Liu, Xianglian; Zhao, Dongliang; Zhao, Yongpeng; Wang, Yuncai
2016-01-01
An analog comparator is one of the core units in all-optical analog-to-digital conversion (AO-ADC) systems, which digitizes different amplitude levels into two levels of logical ‘1’ or ‘0’ by comparing with a defined decision threshold. Although various outstanding photonic ADC approaches have been reported, almost all of them necessitate an electrical comparator to carry out this binarization. The use of an electrical comparator is in contradiction to the aim of developing all-optical devices. In this work, we propose a new concept of an all-optical analog comparator and numerically demonstrate an implementation based on a quarter-wavelength-shifted distributed feedback laser diode (QWS DFB-LD) with multiple quantum well (MQW) structures. Our results show that the all-optical comparator is very well suited for true AO-ADCs, enabling the whole digital conversion from an analog optical signal (continuous-time signal or discrete pulse signal) to a binary representation totally in the optical domain. In particular, this all-optical analog comparator possesses a low threshold power (several mW), high extinction ratio (up to 40 dB), fast operation rate (of the order of tens of Gb/s) and a step-like transfer function. PMID:27550874
CompareSVM: supervised, Support Vector Machine (SVM) inference of gene regularity networks.
Gillani, Zeeshan; Akash, Muhammad Sajid Hamid; Rahaman, M D Matiur; Chen, Ming
2014-11-30
Predication of gene regularity network (GRN) from expression data is a challenging task. There are many methods that have been developed to address this challenge ranging from supervised to unsupervised methods. Most promising methods are based on support vector machine (SVM). There is a need for comprehensive analysis on prediction accuracy of supervised method SVM using different kernels on different biological experimental conditions and network size. We developed a tool (CompareSVM) based on SVM to compare different kernel methods for inference of GRN. Using CompareSVM, we investigated and evaluated different SVM kernel methods on simulated datasets of microarray of different sizes in detail. The results obtained from CompareSVM showed that accuracy of inference method depends upon the nature of experimental condition and size of the network. For network with nodes (<200) and average (over all sizes of networks), SVM Gaussian kernel outperform on knockout, knockdown, and multifactorial datasets compared to all the other inference methods. For network with large number of nodes (~500), choice of inference method depend upon nature of experimental condition. CompareSVM is available at http://bis.zju.edu.cn/CompareSVM/ .
NASA Astrophysics Data System (ADS)
Li, Pu; Yi, Xiaogang; Liu, Xianglian; Zhao, Dongliang; Zhao, Yongpeng; Wang, Yuncai
2016-08-01
An analog comparator is one of the core units in all-optical analog-to-digital conversion (AO-ADC) systems, which digitizes different amplitude levels into two levels of logical ‘1’ or ‘0’ by comparing with a defined decision threshold. Although various outstanding photonic ADC approaches have been reported, almost all of them necessitate an electrical comparator to carry out this binarization. The use of an electrical comparator is in contradiction to the aim of developing all-optical devices. In this work, we propose a new concept of an all-optical analog comparator and numerically demonstrate an implementation based on a quarter-wavelength-shifted distributed feedback laser diode (QWS DFB-LD) with multiple quantum well (MQW) structures. Our results show that the all-optical comparator is very well suited for true AO-ADCs, enabling the whole digital conversion from an analog optical signal (continuous-time signal or discrete pulse signal) to a binary representation totally in the optical domain. In particular, this all-optical analog comparator possesses a low threshold power (several mW), high extinction ratio (up to 40 dB), fast operation rate (of the order of tens of Gb/s) and a step-like transfer function.
Gao, Liang; Yang, Lu; Qian, Shengqiang; Tang, Zhuang; Qin, Feng; Wei, Qiang; Han, Ping; Yuan, Jiuhong
2016-01-01
Cryosurgery (CS) has been used on patients with clinically localized PCa for more than 10 years. However, clinical studies evaluating its effectiveness and safety have reported conflicting results. This systematic assessment was performed to obtain comprehensive evidence regarding the potential benefits and safety of CS compared with those of radiotherapy (RT) and radical prostatectomy (RP), respectively. All controlled trials comparing CS with RT or RP and single-arm studies reporting results of CS therapy were identified through comprehensive searches of PubMed, the Cochrane Library and Embase. Ten publications from seven trials, with totally 1252 patients, were included in the meta-analysis, which revealed no significant differences in comparisons of CS vs RT and CS vs RP for overall survival and disease specific survival. However, a significantly lower disease-free survival could be observed for CS than RP. Moreover, a systematic review of literature focusing on comparative data of databases and materials of single-arm trials revealed satisfactory survival results in both primary and salvage CS. Our results showed that cryosurgery would be a relatively effective method for clinically localized prostate cancer with survival results comparable to radiotherapy and radical prostatectomy. However, the large percentage of complications caused by cryosurgery should be carefully monitored. PMID:27271239
Hosseinpour-Feizi, Hojjat; Soleimanpour, Jafar; Sales, Jafar Ganjpour; Arzroumchilar, Ali
2011-01-01
Purpose The aim of this study was to investigate the interobserver agreement of the Lenke and King classifications for adolescent idiopathic scoliosis, and to compare the results of surgery performed based on classification of the scoliosis according to each of these classification systems. Methods The study was conducted in Shohada Hospital in Tabriz, Iran, between 2009 and 2010. First, a reliability assessment was undertaken to assess interobserver agreement of the Lenke and King classifications for adolescent idiopathic scoliosis. Second, postoperative efficacy and safety of surgery performed based on the Lenke and King classifications were compared. Kappa coefficients of agreement were calculated to assess the agreement. Outcomes were compared using bivariate tests and repeated measures analysis of variance. Results A low to moderate interobserver agreement was observed for the King classification; the Lenke classification yielded mostly high agreement coefficients. The outcome of surgery was not found to be substantially different between the two systems. Conclusion Based on the results, the Lenke classification method seems advantageous. This takes into consideration the Lenke classification’s priority in providing details of curvatures in different anatomical surfaces to explain precise intensity of scoliosis, that it has higher interobserver agreement scores, and also that it leads to noninferior postoperative results compared with the King classification method. PMID:22267934
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koh, J. H.; Robertson, A.; Jonkman, J.
Need to modify simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions. the SWAY system in both turbine operating and nonoperating conditions. Mixed results were observed when comparing the simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions. without the new tower-load capability to examine its influence on the response characteristics of the system. This is important in situations when the turbine is parked in survival conditions. The simulation results were then compared to measured data from the SWAY system in bothmore » turbine operating and nonoperating conditions. Mixed results were observed when comparing the simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions.« less
Marinov, V; Draganov, K; Gaydarski, R; Katev, N N
2013-01-01
There is a large variety of proposed conservative, invasive, endoscopic and surgical methods for treatment of chronic pancreatitis and its complications. This study presents a comparative analysis of the results from each group of patients subjected to drainage, resection, denervation and other operative techniques for a total of 91 patients with chronic pancreatitis and its complications. Drainage and resection operative techniques yield comparable results in terms of postoperative pain control 93.1% and 100%, perioperative mortality--3.17% and 5.8%, perioperative morbidity--7.9% and 11.7%, respectively. There is a significant increase in the instances of diabetes in the resection group. Right-side semilunar ganglionectomy is a good method for pain control as an accompanying procedure in the course of another main operative technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fasso, A.; Ferrari, A.; Ferrari, A.
In 1974, Nelson, Kase and Svensson published an experimental investigation on muon shielding around SLAC high-energy electron accelerators [1]. They measured muon fluence and absorbed dose induced by 14 and 18 GeV electron beams hitting a copper/water beamdump and attenuated in a thick steel shielding. In their paper, they compared the results with the theoretical models available at that time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results are then compared between the codes, andmore » with the SLAC data.« less
Design and Analysis of Cognitive Interviews for Comparative Multinational Testing
Fitzgerald, Rory; Padilla, José-Luis; Willson, Stephanie; Widdop, Sally; Caspar, Rachel; Dimov, Martin; Gray, Michelle; Nunes, Cátia; Prüfer, Peter; Schöbi, Nicole; Schoua-Glusberg, Alisú
2011-01-01
This article summarizes the work of the Comparative Cognitive Testing Workgroup, an international coalition of survey methodologists interested in developing an evidence-based methodology for examining the comparability of survey questions within cross-cultural or multinational contexts. To meet this objective, it was necessary to ensure that the cognitive interviewing (CI) method itself did not introduce method bias. Therefore, the workgroup first identified specific characteristics inherent in CI methodology that could undermine the comparability of CI evidence. The group then developed and implemented a protocol addressing those issues. In total, 135 cognitive interviews were conducted by participating countries. Through the process, the group identified various interpretive patterns resulting from sociocultural and language-related differences among countries as well as other patterns of error that would impede comparability of survey data. PMID:29081719
Detailed characteristics of drop-laden mixing layers: LES predictions compared to DNS
NASA Technical Reports Server (NTRS)
Okong'o, N.; Leboissetier, A.; Bellan, J.
2004-01-01
Results have been compared from Direct Numerical Simulation (DNS) and Large Eddy Simulation (LES) of a temporal mixing layer laden with evaporating drops, to assess the ability of LES to reproduce detailed characteristics of DNS.
Finite element modelling of FRC beams containing PVA and Basalt fibres: A comparative study
NASA Astrophysics Data System (ADS)
Ayub, Tehmina; Khan, Sadaqat Ullah
2017-09-01
The endeavour of current study is to compare the flexural behaviour and three dimensional (3D) finite element analysis (FEA) and the results of FEM are compared with the experimental results of 07 HPFRC beams. Out of seven (07), 01 beam of plain concrete without fibres was cast as a control beam. Three (03) beams containing 1, 2 and 3% volume of PVA fibres were prepared by using HPFRC mixes while, the remaining other three (03) beams were prepared using HPFRC mixes containing 1, 2 and 3% volume of Basalt fibres. In order to ensure flexural failure, three-point bending load was applied at the mid span of all beams. The maximum flexural load and corresponding deflection and strains at the mid span attained prior to the failure were obtained as flexural test results. The FEM results were obtained by simulating all beams in ATENA 3D program and verified through flexural test results. Both of the results of FEM and Experiment showed good agreement with each other.
Feasibility of quasi-random band model in evaluating atmospheric radiance
NASA Technical Reports Server (NTRS)
Tiwari, S. N.; Mirakhur, N.
1980-01-01
The use of the quasi-random band model in evaluating upwelling atmospheric radiation is investigated. The spectral transmittance and total band adsorptance are evaluated for selected molecular bands by using the line by line model, quasi-random band model, exponential sum fit method, and empirical correlations, and these are compared with the available experimental results. The atmospheric transmittance and upwelling radiance were calculated by using the line by line and quasi random band models and were compared with the results of an existing program called LOWTRAN. The results obtained by the exponential sum fit and empirical relations were not in good agreement with experimental results and their use cannot be justified for atmospheric studies. The line by line model was found to be the best model for atmospheric applications, but it is not practical because of high computational costs. The results of the quasi random band model compare well with the line by line and experimental results. The use of the quasi random band model is recommended for evaluation of the atmospheric radiation.
Humphries, Ailsa; Chen, Zhe; Neumann, Ewald
2017-01-01
Previous studies have shown that stimulus repetition can lead to reliable behavioral improvements. Although this repetition priming (RP) effect has been reported in a number of paradigms using a variety of stimuli including words, objects, and faces, only a few studies have investigated mathematical cognition involving arithmetic computation, and no prior research has directly compared RP effects in a linguistic task with an arithmetic task. In two experiments, we used a within-subjects design to investigate and compare the magnitude of RP, and the effects of changing the color or the response hand for repeated, otherwise identical, stimuli in a word and an arithmetic categorization task. The results show that the magnitude of RP was comparable between the two tasks and that changing the color or the response hand had a negligible effect on priming in either task. These results extended previous findings in mathematical cognition. They also indicate that priming does not vary with stimulus domain. The implications of the results were discussed with reference to both facilitation of component processes and episodic memory retrieval of stimulus-response binding.
Comparative analysis of tumor spheroid generation techniques for differential in vitro drug toxicity
Raghavan, Shreya; Rowley, Katelyn R.; Mehta, Geeta
2016-01-01
Multicellular tumor spheroids are powerful in vitro models to perform preclinical chemosensitivity assays. We compare different methodologies to generate tumor spheroids in terms of resultant spheroid morphology, cellular arrangement and chemosensitivity. We used two cancer cell lines (MCF7 and OVCAR8) to generate spheroids using i) hanging drop array plates; ii) liquid overlay on ultra-low attachment plates; iii) liquid overlay on ultra-low attachment plates with rotating mixing (nutator plates). Analysis of spheroid morphometry indicated that cellular compaction was increased in spheroids generated on nutator and hanging drop array plates. Collagen staining also indicated higher compaction and remodeling in tumor spheroids on nutator and hanging drop arrays compared to conventional liquid overlay. Consequently, spheroids generated on nutator or hanging drop plates had increased chemoresistance to cisplatin treatment (20-60% viability) compared to spheroids on ultra low attachment plates (10-20% viability). Lastly, we used a mathematical model to demonstrate minimal changes in oxygen and cisplatin diffusion within experimentally generated spheroids. Our results demonstrate that in vitro methods of tumor spheroid generation result in varied cellular arrangement and chemosensitivity. PMID:26918944
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Comparative Microbial Modules Resource: Generation and Visualization of Multi-species Biclusters
Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard
2011-01-01
The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures – results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. PMID:22144874
Comparative microbial modules resource: generation and visualization of multi-species biclusters.
Kacmarczyk, Thadeous; Waltman, Peter; Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard
2011-12-01
The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures - results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. © 2011 Kacmarczyk et al.
Fatigue Life Analysis of Tapered Hybrid Composite Flexbeams
NASA Technical Reports Server (NTRS)
Murri, Gretchen B.; Schaff, Jeffery R.; Dobyns, Alan L.
2002-01-01
Nonlinear-tapered flexbeam laminates from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. The two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) obtained from the above codes using the virtual crack closure technique (VCCT) at a resin crack location in the flexbeams are presented for both hybrid material types. These results compare well with each other and suggest that the initial delamination growth from the resin crack toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves and compared with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared reasonably well with the test results.
Hansen, Clint; Venture, Gentiane; Rezzoug, Nasser; Gorce, Philippe; Isableu, Brice
2014-05-07
Over the last decades a variety of research has been conducted with the goal to improve the Body Segment Inertial Parameters (BSIP) estimations but to our knowledge a real validation has never been completely successful, because no ground truth is available. The aim of this paper is to propose a validation method for a BSIP identification method (IM) and to confirm the results by comparing them with recalculated contact forces using inverse dynamics to those obtained by a force plate. Furthermore, the results are compared with the recently proposed estimation method by Dumas et al. (2007). Additionally, the results are cross validated with a high velocity overarm throwing movement. Throughout conditions higher correlations, smaller metrics and smaller RMSE can be found for the proposed BSIP estimation (IM) which shows its advantage compared to recently proposed methods as of Dumas et al. (2007). The purpose of the paper is to validate an already proposed method and to show that this method can be of significant advantage compared to conventional methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
O'Donoghue, Amie C; Williams, Pamela A; Sullivan, Helen W; Boudewyns, Vanessa; Squire, Claudia; Willoughby, Jessica Fitts
2014-11-01
Although pharmaceutical companies cannot make comparative claims in direct-to-consumer (DTC) ads for prescription drugs without substantial evidence, the U.S. Food and Drug Administration permits some comparisons based on labeled attributes of the drug, such as dosing. Researchers have examined comparative advertising for packaged goods; however, scant research has examined comparative DTC advertising. We conducted two studies to determine if comparative claims in DTC ads influence consumers' perceptions and recall of drug information. In Experiment 1, participants with osteoarthritis (n=1934) viewed a fictitious print or video DTC ad that had no comparative claim or made an efficacy comparison to a named or unnamed competitor. Participants who viewed print (but not video) ads with named competitors had greater efficacy and lower risk perceptions than participants who viewed unnamed competitor and noncomparative ads. In Experiment 2, participants with high cholesterol or high body mass index (n=5317) viewed a fictitious print or video DTC ad that had no comparative claim or made a comparison to a named or unnamed competitor. We varied the type of comparison (of indication, dosing, or mechanism of action) and whether the comparison was accompanied by a visual depiction. Participants who viewed print and video ads with named competitors had greater efficacy perceptions than participants who viewed unnamed competitor and noncomparative ads. Unlike Experiment 1, named competitors in print ads resulted in higher risk perceptions than unnamed competitors. In video ads, participants who saw an indication comparison had greater benefit recall than participants who saw dosing or mechanism of action comparisons. In addition, visual depictions of the comparison decreased risk recall for video ads. Overall, the results suggest that comparative claims in DTC ads could mislead consumers about a drug's efficacy and risk; therefore, caution should be used when presenting comparative claims in DTC ads. Published by Elsevier Ltd.
Ivanova, Juliana; Gluhcheva, Yordanka; Dimova, Donika; Pavlova, Ekaterina; Arpadjan, Sonja
2016-01-01
In this study, we present a comparative assessment of the effects of two polyether ionophorous antibiotics (monensin and salinomycin) on the concentrations of lead (Pb), cooper (Cu), zinc (Zn) and iron (Fe) in the kidneys, spleen, liver and brain of Pb-intoxicated animals. Our data demonstrated that the intoxication of ICR male mice with Pb salt resulted in a significant accumulation of Pb in all studied organs of the mice compared to the untreated control animals. The biodistribution of the toxic metal was in the order kidneys>spleen>liver>brain. The treatment of the Pb-intoxicated animals with tetraethylammonium salts of monensic and salinomycinic acids significantly decreased the concentration of the toxic metal ion compared to the toxic control. The effect varied in the interval 38% (for kidneys) to 52% (for brain) compared to the toxic control group (Pb). The tetraethylammonium salt of salinomycinic acid was more effective in reducing the Pb concentration in the brain of the Pb-treated mice compared to monensin. Pb-intoxication did not affect significantly the Zn endogenous concentration compared to the normal values. The treatment of ICR male mice with Pb-salt decreased the Cu concentration in the spleen and increased the Cu concentration in the liver compared to the untreated control animals. The detoxification of the Pb-intoxicated mice with tetraethylammonium salts of salinomycinic and monensic acids restored the Cu concentration in the spleen, but did not affect the Cu levels in the liver. The Pb-intoxication of the ICR mice resulted in a significant decrease of the Fe-concentration in the spleen and liver compared to the untreated control animals. The administration of the tetraethylammonium salts of salinomycinic and monensic acids to the Pb-treated animals restored the levels of Fe in both organs. Copyright © 2015 Elsevier GmbH. All rights reserved.
Salameh, Habeeb; Hanayneh, Muhannad Al; Masadeh, Maen; Naseemuddin, Mohammed; Matin, Tasnia; Erwin, Angelika; Singal, Ashwani K
2016-09-28
Background and Aims: Patatin-like phospholipase domain protein 3 ( PNPLA3 ) polymorphisms ( rs738409 C>G) are associated with non-alcoholic fatty liver disease (NAFLD). We performed a systematic review and meta-analysis to examine the association of PNPLA3 polymorphisms with the spectrum and severity of this disease. Methods: Studies evaluating the association between the PNPLA3 polymorphism spectrum (fatty liver, steatohepatitis, cirrhosis, and hepatocellular carcinoma) and NAFLD were included. Pooled data are reported as odds ratios (ORs) with 95% confidence intervals. Results: Of 393 potentially relevant studies, 35 on NAFLD were included in the analysis. Compared to healthy controls, the pooled ORs for rs738409 CG and GG compared to CC among patients with non-alcoholic fatty liver (NAFL) were 1.46 (1.16-1.85) and 2.76 (2.30-3.13), and were 1.75 (1.24-2.46) and 4.44 (2.92-6.76) among patients with non-alcoholic steatohepatitis respectively. The respective ORs for CG and GG compared to the CC genotype were 2.35 (0.90-6.13) and 5.05 (1.47-17.29) when comparing non-alcoholic hepatocellular carcinoma to NAFL patients. Among the NAFLD patients, the ORs for G allele frequency when comparing steatosis grade 2-3 to grade 0-1 NAFL, when comparing the NAFLD activity score of ≥ 4 to score ≤ 3, when comparing NASH to NAFLD, when comparing the presence of lobular inflammation to absence, and when comparing the presence of hepatocyte ballooning to absence were 2.33 (1.43-3.80), 1.80 (1.36-2.37), 1.66 (1.42-1.94), 1.58 (1.19-2.10), and 2.63 (1.87-3.69) respectively. Subgroup analysis based on ethnicity showed similar results. Conclusions: PNPLA3 polymorphisms have strong association with the risk for and severity of NAFLDs. PNPLA3 polymorphism plays an evolving role in diagnosis and treatment decisions in patients with NAFLD.
Zwijnenberg, Nicolien C; Bloemendal, Evelien; Damman, Olga C; de Jong, Judith D; Delnoij, Diana MJ; Rademakers, Jany JD
2016-01-01
Background The Internet is increasingly being used to provide patients with information about the quality of care of different health care providers. Although online comparative health care information is widely available internationally, and patients have been shown to be interested in this information, its effect on patients’ decision making is still limited. Objective This study aimed to explore patients’ preferences regarding information presentation and their values concerning tailored comparative health care information. Meeting patients’ information presentation needs might increase the perceived relevance and use of the information. Methods A total of 38 people participated in 4 focus groups. Comparative health care information about hip and knee replacement surgery was used as a case example. One part of the interview focused on patients’ information presentation preferences, whereas the other part focused on patients’ values of tailored information (ie, showing reviews of patients with comparable demographics). The qualitative data were transcribed verbatim and analyzed using the constant comparative method. Results The following themes were deduced from the transcripts: number of health care providers to be presented, order in which providers are presented, relevancy of tailoring patient reviews, and concerns about tailoring. Participants’ preferences differed concerning how many and in which order health care providers must be presented. Most participants had no interest in patient reviews that were shown for specific subgroups based on age, gender, or ethnicity. Concerns of tailoring were related to the representativeness of results and the complexity of information. A need for information about the medical specialist when choosing a hospital was stressed by several participants. Conclusions The preferences for how comparative health care information should be presented differ between people. “Information on demand” and information about the medical specialist might be promising ways to increase the relevancy and use of online comparative health care information. Future research should focus on how different groups of people use comparative health care information for different health care choices in real life. PMID:27895006
Escamilla, Rafael F; Fleisig, Glenn S; Groeschner, Dave; Akizuki, Ken
2017-12-01
In professional baseball pitchers, pitching biomechanics have not been examined for the slider, and the only known study for the curveball and changeup examined limited kinetics. Moreover, no known studies have investigated pitching biomechanics between strikes and balls. Purpose/Hypothesis: The purpose was to compare pitching biomechanics in professional baseball pitchers among the fastball, slider, curveball, and changeup and between balls and strikes. It was hypothesized that pitching kinematics and kinetics would be similar among the slider, fastball, and curveball; shoulder and elbow forces and torques would be significantly lower in the changeup; and pitching biomechanics would be similar between balls and strikes. Controlled laboratory study. Among 18 professional baseball pitchers, 38 reflective markers were positioned on the body and each player threw 32 to 40 maximum effort pitches-consisting of the fastball, curveball, slider, and changeup pitch types-from a regulation mound to a catcher. The markers were tracked by 18 high-speed 180-Hz cameras, and data were processed and run through a computer program to calculate 25 kinematic parameters, 7 kinetic parameters, and 4 temporal parameters for each pitch type and for both strikes and balls. A 2-way repeated-measures analysis of variance ( P < .01) was used to assess pitching biomechanical differences among pitch type and pitch result (balls vs strikes). During arm cocking, elbow varus torque was 8% to 9% greater in the fastball and slider compared with the changeup, shoulder horizontal adduction torque was 17% to 20% greater in the slider and curveball compared with the changeup, and shoulder anterior force was 13% greater in the curveball compared with the changeup. During arm deceleration, elbow flexor torque was 9% to 14% greater in the fastball compared with the curveball and changeup, and elbow and shoulder proximal forces were 10% to 14% greater in the fastball, slider, and curveball compared with the changeup. At ball release, forward trunk tilt was 16% to 19% greater in the fastball and curveball compared with the changeup, contralateral trunk tilt was 26% to 41% greater in the curveball compared with the slider and changeup, knee flexion was 18% greater in the changeup compared with the fastball, and the knee extended 7° more from lead foot contact to ball release in the fastball compared with the changeup. During arm cocking, pelvis angular velocity was 7% to 8% greater in the fastball compared with the curveball and changeup, and upper trunk angular velocity was 5% greater in the fastball compared with the changeup. During arm acceleration, shoulder internal rotation angular velocity was 6% to 7% greater in the fastball, slider, and curveball compared with the changeup, and ball velocity at ball release was 11% to 18% greater in the fastball compared with the slider, changeup, and curveball and 6% greater in the slider compared with the curveball. For all the kinematic, kinetic, and temporal parameters, analysis showed no significant differences between balls and strikes and no significant interactions between pitch type and pitch result. Nearly all kinetic differences among pitch types occurred between the changeup and the remaining 3 pitch types. Shoulder and elbow forces and torques and injury risk were greater among the fastball, slider, and curveball compared with the changeup but were similar among the fastball, slider, and curveball. Body segment and joint positions were similar among all pitch types at lead foot contact and at maximum shoulder external rotation; however, at ball release, throwing a fastball and curveball resulted in greater knee extension and more forward and contralateral trunk tilt compared with throwing a changeup and slider. Movement speeds for the pelvis, upper trunk, and shoulder were greatest in the fastball and least in the changeup and were generally similar among the fastball, slider, and curveball. The timing of when pelvis, upper trunk, elbow, and shoulder velocities occurred among the fastball, slider, curveball, and changeup was similar, and no kinematic or kinetic differences were noted between throwing balls and strikes. The results from the current study will help clinicians understand differences in pitching biomechanics in professional baseball pitchers among the fastball, slider, curveball, and changeup; the study provides limited insight into shoulder and elbow injury risk associated with different types of pitches.
Ellart, J; François, C; Calibre, C; Guerreschi, P; Duquennoy-Martinot, V
2016-10-01
Breast asymmetry is defined by a difference in breast shape and/or volume. The goal of this study was to assess the stability of the surgical results and to highlight predictive factors for deterioration in results. This retrospective and monocentric study included all patients presenting constitutional isolated asymmetry, Poland's syndrome, asymmetric tuberous breast or pectus excavatum treated between 1980 and 2015. The statistical analysis included 144 patients and contained two parts. The first analysis compared patients with or without breast implant. Results were significant only for symmetry of shape, with better outcomes without breast implant (P=0.0170). The second analysis compared the subgroups of patients with breast asymmetry, according to the etiology. Patients with tuberous breasts and constitutional isolated asymmetry have been compared. We found a significant difference only regarding the long-term results (P=0.0091). Patients with tuberous breasts had deteriorating in results over time. Patients with Poland's syndrome, compared to patients with constitutional isolated asymmetry, had significantly less good results for symmetry of volume, of shape, of areola, and for early results (P<0.025). Concerning patients with pectus excavatum, the early and long-term results and the stability were good for most patients. Better results have been obtained with similar surgical procedures on both sides. Predictive factors for instability of results were the use of unilateral breast implant, weight variations, pregnancies and breast-feeding, the use of hormonal treatments, ageing and tuberous malformation. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Caballero, Julio; Fernández, Michael; Coll, Deysma
2010-12-01
Three-dimensional quantitative structure-activity relationship studies were carried out on a series of 28 organosulphur compounds as 15-lipoxygenase inhibitors using comparative molecular field analysis and comparative molecular similarity indices analysis. Quantitative information on structure-activity relationships is provided for further rational development and direction of selective synthesis. All models were carried out over a training set including 22 compounds. The best comparative molecular field analysis model only included steric field and had a good Q² = 0.789. Comparative molecular similarity indices analysis overcame the comparative molecular field analysis results: the best comparative molecular similarity indices analysis model also only included steric field and had a Q² = 0.894. In addition, this model predicted adequately the compounds contained in the test set. Furthermore, plots of steric comparative molecular similarity indices analysis field allowed conclusions to be drawn for the choice of suitable inhibitors. In this sense, our model should prove useful in future 15-lipoxygenase inhibitor design studies. © 2010 John Wiley & Sons A/S.
Factors that Affect Suicide Attempts of Adolescents in Multicultural Families in Korea.
Park, Subin; Lee, Yeeun
2016-11-28
We examined the factors that affect suicide attempts adolescents multicultural families in South Korea. The participants were 727 adolescents whose mothers and/or fathers were born outside of South Korea (376 males and 351 females). Among them, 41 (weighted prevalence 6.2%) had attempted suicide during the last 12 months. Female gender, residence in large cities (compared with in rural areas), living with relatives/alone/with friends/in a dormitory or living in a facility (compared with living with family), high and low socio-economic status (compared with a middle level), high and low academic performance (compared with a middle level), severe perceived stress (compared with non-severe stress), conflicts with a teacher (compared with conflicts with parent), and foreign-father/-parent families (compared with foreign-mother family) were associated with increased odds of suicide attempt. The results indicate that greater awareness of the possibility of suicidal behavior is prudent for adolescents in multicultural families with certain risk factors, such as being from a foreign-parents family, living separately from the family, and having conflicts with a teacher.
NASA Astrophysics Data System (ADS)
Rahmanian, M.; Fathi, R.; Shojaei, F.
2017-11-01
The single-charge transfer process in collision of protons with helium atoms in their ground states is investigated. The model utilizes the second-order three-body Born distorted-wave approximation (BDW-3B) with correct Coulomb boundary conditions to calculate the differential and total cross sections at intermediate and high energies. The role of the passive electrons and electron-electron correlations are studied by comparing our results and the BDW-4B calculations with the complete perturbation potential. The present results are also compared with other theories, and the Thomas scattering mechanism is investigated. The obtained results are also compared with the recent experimental measurements. For the prior differential cross sections, the comparisons show better agreement with the experiments at smaller scattering angles. The agreement between the total cross sections and the BDW-4B results as well as the experimental data is good at higher impact energies.
Bayesian parameter estimation for chiral effective field theory
NASA Astrophysics Data System (ADS)
Wesolowski, Sarah; Furnstahl, Richard; Phillips, Daniel; Klco, Natalie
2016-09-01
The low-energy constants (LECs) of a chiral effective field theory (EFT) interaction in the two-body sector are fit to observable data using a Bayesian parameter estimation framework. By using Bayesian prior probability distributions (pdfs), we quantify relevant physical expectations such as LEC naturalness and include them in the parameter estimation procedure. The final result is a posterior pdf for the LECs, which can be used to propagate uncertainty resulting from the fit to data to the final observable predictions. The posterior pdf also allows an empirical test of operator redundancy and other features of the potential. We compare results of our framework with other fitting procedures, interpreting the underlying assumptions in Bayesian probabilistic language. We also compare results from fitting all partial waves of the interaction simultaneously to cross section data compared to fitting to extracted phase shifts, appropriately accounting for correlations in the data. Supported in part by the NSF and DOE.
Hyun Kim; Sun-Young Yoo; Ji Sung Kim; Zihuan Wang; Woon Hee Lee; Kyo-In Koo; Jong-Mo Seo; Dong-Il Cho
2017-07-01
Inhibition of polydimethylsiloxane (PDMS) polymerization could be observed when spin-coated over vinyl substrates. The degree of polymerization, partially curing or fully curing, depended on the PDMS thickness coated over the vinyl substrate. This characteristic was exploited to achieve simple and fast PDMS patterning method using a vinyl adhesive layer patterned through a cutting plotter. The proposed patterning method showed results resembling PDMS etching. Therefore, patterning PDMS over PDMS, glass, silicon, and gold substrates were tested to compare the results with conventional etching methods. Vinyl stencils with widths ranging from 200μm to 1500μm were used for the procedure. To evaluate the accuracy of the cutting plotter, stencil designed on the AutoCAD software and the actual stencil widths were compared. Furthermore, this method's accuracy was also evaluated by comparing the widths of the actual stencils and etched PDMS results.
Heating of solid targets with laser pulses
NASA Technical Reports Server (NTRS)
Bechtel, J. H.
1975-01-01
Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.
Influence of stearic acid on postprandial lipemia and hemostatic function.
Sanders, Thomas A B; Berry, Sarah E E
2005-12-01
It has been suggested that fats rich in stearic acid may result in exaggerated postprandial lipemia and have adverse effects on hemostatic function. The effects of test meals containing different saturated and monounsaturated FA were compared in healthy subjects in a series of studies to investigate this hypothesis. Stearic acid, when present as cocoa butter, resulted in similar postprandial lipemia and factor VII activation compared with a meal containing high-oleic sunflower oil. Stearic acid when presented as shea butter or as randomized stearate-rich TAG resulted in decreased postprandial lipemia and decreased postprandial activation of factor VII. Stearic acid-rich test meals did not result in impaired fibrinolytic activity compared with either a low-fat meal or a meal high in oleate. The difference in responses between the different stearic acid-rich fats appears to be due to varying solid fat contents of the fats at 37 degrees C.
Hot fire test results of subscale tubular combustion chambers
NASA Technical Reports Server (NTRS)
Kazaroff, John M.; Jankovsky, Robert S.; Pavli, Albert J.
1992-01-01
Advanced, subscale, tubular combustion chambers were built and test fired with hydrogen-oxygen propellants to assess the increase in fatigue life that can be obtained with this type of construction. Two chambers were tested: one ran for 637 cycles without failing, compared to a predicted life of 200 cycles for a comparable smooth-wall milled-channel liner configuration. The other chamber failed at 256 cycles, compared to a predicted life of 118 cycles for a comparable smooth-wall milled-channel liner configuration. Posttest metallographic analysis determined that the strain-relieving design (structural compliance) of the tubular configuration was the cause of this increase in life.
Ukai, Tomohiko; Shikata, Satoru; Nakayama, Takeo; Takemura, Yousuke C
2017-07-01
We compared the results of prospective and retrospective cohort studies in the field of digestive surgery to clarify whether the results of prospective cohort studies were more similar to those of randomized controlled trials (RCTs). We conducted a secondary analysis of the results to compare the results of RCTs with those of cohort studies in meta-analyses of 18 digestive surgical topics. The data from the prospective and retrospective cohort studies were combined. The summary estimates of each design were compared with those of RCTs. We used the Z score to investigate discrepancies. Twenty-nine outcomes of 11 topics were investigated in 289 cohort studies (prospective, n = 69; retrospective, n = 220). These were compared with the outcomes of 123 RCTs. In comparison to retrospective studies, the summary estimates of the prospective cohort studies were more similar to those of the RCTs [19/29 (prospective) vs. 10/29 (retrospective), P = 0.035). Five of the 29 outcomes of prospective studies and 6 of 29 outcomes of retrospective studies (P = 0.99) showed significant discrepancies in comparison to RCTs. In the digestive surgical field, the results of prospective cohort studies tended to be more similar to those of RCTs than retrospective studies; however, there were no significant discrepancies between the two types of cohort study.
Ryodi, Essi; Metso, Saara; Huhtala, Heini; Välimäki, Matti; Auvinen, Anssi; Jaatinen, Pia
2018-06-08
BACKGROUND Hyperthyroid patients remain at an increased risk of cardiovascular diseases (CVDs) after restoring euthyroidism. The impact of the different treatment modalities of hyperthyroidism on future CVD risk remains unclear. The aim of this paper is to assess cardiovascular morbidity and mortality in hyperthyroidism before and after the treatment, and to compare the effects of two different treatment modalities, radioactive iodine (RAI) and thyroid surgery. METHODS A comparative cohort study was conducted among 6,148 hyperthyroid patients treated either with RAI or thyroidectomy, and 18,432 age- and gender-matched controls. Firstly, hospitalizations due to CVDs prior to the treatment were analyzed. Secondly, the hazard ratios (HR) for any new hospitalization and mortality due to CVDs after the treatment were estimated among all the hyperthyroid patients compared to the age- and gender-matched controls and also in the RAI-treated patients compared to the thyroidectomy-treated patients. The results were adjusted for prevalent CVDs at the time of treatment. RESULTS Before the treatment of hyperthyroidism, hospitalizations due to all CVDs were more common in the hyperthyroid patients compared to the controls (OR 1.61, 95% CI 1.49-1.73). During the post-treatment follow-up, hospitalizations due to CVDs remained more frequent among the patients (HR 1.15, 95% CI 1.09-1.21), but there was no difference in CVD mortality (HR 0.93, 95% CI 0.84-1.03). Compared to the patients treated with thyroidectomy, the RAI-treated patients had a higher risk of hospitalization due to all CVDs (HR 1.17), and atrial fibrillation (HR 1.28), as well as a higher CVD mortality (HR 2.56). Yet, treatment with RAI resulting in hypothyroidism was not associated with increased CVD morbidity compared with thyroidectomy. CONCLUSIONS Hyperthyroidism increases the risk of CVD-related hospitalization, and the risk is sustained for up to two decades after treatment with RAI or surgery. Hyperthyroid patients treated with RAI remain at a higher CVD risk compared to patients treated with thyroidectomy. Hypothyroidism during the follow-up, however, predicts better cardiovascular outcome.
Cai, Xiaoling; Yang, Wenjia; Gao, Xueying; Zhou, Lingli; Han, Xueyao; Ji, Linong
2016-01-01
Aim The aim of this study is to compare the effects of hypoglycemic treatments in groups of patients categorized according to the mean baseline body mass indexes (BMIs). Methods Studies were identified by a literature search and all the studies were double blind, placebo-controlled randomized trials in type 2 diabetes patients; study length of ≥12 weeks with the efficacy evaluated by changes in HbA1c from baseline in groups. The electronic search was first conducted in January 2015 and repeated in June 2015. Results 227 studies were included. Treatment with sulfonylureas was compared with placebo in overweight patients and resulted in a significantly greater change in the HbA1c levels (weighted mean difference (WMD), −1.39%) compared to obese patients (WMD, −0.77%)(p<0.05). Treatment with metformin in overweight patients resulted in a comparable change in the HbA1c levels (WMD, −0.99%) compared to obese patients (WMD, −1.06%)(p>0.05). Treatment with alpha glucosidase inhibitors in normal weight patients was associated with a HbA1c change (WMD, −0.94%) that was comparable that in overweight (WMD, −0.72%) and obese patients (WMD, −0.56%)(p>0.05). Treatment with thiazolidinediones in normal weight patients was associated with a HbA1c change (WMD, −1.04%) that was comparable with that in overweight (WMD, −1.02%) and obese patients (WMD, −0.88%)(p>0.05). Treatment with DPP-4 inhibitors in normal weight patients was associated with a HbA1c change (WMD, −0.93%) that was comparable with that in overweight (WMD, −0.66%) and obese patients (WMD, −0.61%)(p>0.05). In total, of the seven hypoglycemic agents, regression analysis indicated that the mean baseline BMI was not associated with the mean HbA1c changes from baseline. Conclusion In each kind of hypoglycemic therapy in type 2 diabetes, the baseline BMI was not associated with the efficacy of HbA1c changes from baseline. PMID:27935975
Comparative Study Of Four Models Of Turbulence
NASA Technical Reports Server (NTRS)
Menter, Florian R.
1996-01-01
Report presents comparative study of four popular eddy-viscosity models of turbulence. Computations reported for three different adverse pressure-gradient flowfields. Detailed comparison of numerical results and experimental data given. Following models tested: Baldwin-Lomax, Johnson-King, Baldwin-Barth, and Wilcox.
Motor fuels : issues related to reformulated gasoline, oxygenated fuels, and biofuels
DOT National Transportation Integrated Search
1996-06-01
This report by the General Accounting Office summarizes (1) the results of : federal and other studies on the cost-effectiveness of using reformulated : gasoline compared to other measures to control automotive emissions and compare : the price estim...
Lenhard, Fabian; Ssegonja, Richard; Andersson, Erik; Feldman, Inna; Rück, Christian; Mataix-Cols, David; Serlachius, Eva
2017-05-17
To evaluate the cost-effectiveness of a therapist-guided internet-delivered cognitive behaviour therapy (ICBT) intervention for adolescents with obsessive-compulsive disorder (OCD) compared with untreated patients on a waitlist. Single-blinded randomised controlled trial. A research clinic within the regular child and adolescent mental health service in Stockholm, Sweden. Sixty-seven adolescents (12-17 years) with a Diagnostic and Statistical Manual of Mental Disorders Fifth Edition diagnosis of OCD. Either a 12-week, therapist-guided ICBT intervention or a wait list condition of equal duration. Cost data were collected at baseline and after treatment, including healthcare use, supportive resources, prescription drugs, prescription-free drugs, school absence and productivity loss, as well as the cost of ICBT. Health outcomes were defined as treatment responder rate and quality-adjusted life years gain. Bootstrapped mixed model analyses were conducted comparing incremental costs and health outcomes between the groups from the societal and healthcare perspectives. Compared with waitlist control, ICBT generated substantial societal cost savings averaging US$-144.98 (95% CI -159.79 to -130.16) per patient. The cost reductions were mainly driven by reduced healthcare use in the ICBT group. From the societal perspective, the probability of ICBT being cost saving compared with waitlist control was approximately 60%. From the healthcare perspective, the cost per additional responder to ICBT compared with waitlist control was approximately US$78. The results suggest that therapist-guided ICBT is a cost-effective treatment and results in societal cost savings, compared with patients who do not receive evidence-based treatment. Since, at present, most patients with OCD do not have access to evidence-based treatments, the results have important implications for the increasingly strained national and healthcare budgets. Future studies should compare the cost-effectiveness of ICBT with regular face-to-face CBT. NCT02191631. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
PAH effects on meio- and microbial benthic communities strongly depend on bioavailability.
Lindgren, J Fredrik; Hassellöv, Ida-Maja; Dahllöf, Ingela
2014-01-01
The effects of anthropogenic pollutants in dissimilar habitats can vary depending on differences in bioavailability. The factors determining bioavailability are not yet fully understood. This study was performed to evaluate whether analysis of total PAH concentrations in sediments is a satisfactory measurement to indicate environmental effects or if bioavailability is needed to be taken into account. We have here performed a 60-day experiment, where nominal PAH concentrations of 1,300 μg/kg sediment were added to three different marine sediments. Meiofaunal and microbial communities were analyzed for alterations in community response at 30 and 60 days. Results showed that bioavailability of PAHs varied between the three different sediments. Nonetheless, the petroleum addition gave rise to significant negative effects on all three sediments at both time points. The two direct measurements of toxicity on the microbial community, potential nitrification and denitrification, displayed a lower effect of the PAH addition in the muddy sediment at both time points, compared to the other two sediment types. No effects were seen in the analysis of meiofaunal community structure. Measurements of PAH bioavailability in the three sediment types concurred with the results from the microbial community, revealing a lower bioavailability in the muddy sediment compared to the other two sediment types, 34% compared to sandy and 18% compared to organic at day 0. At day 60 it was 61% lower compared to sandy and 20% lower compared to organic. The negative effects of the PAH addition on the microbial nitrogen cycle were in six out of eight cases best correlated to the amount of alkylated bioavailable PAH in the sediments, and thus microbial nitrogen cycle is a possible good indicator for assessing PAH-induced stress. The results presented here have implications for risk analysis studies of petroleum-contaminated marine sediments; consequently, sediment characteristics and its effects on bioavailability are important to include. In addition, these results add to the understanding that bioavailability measurements of PAHs are a more correct assessment compared to measurements of total PAH concentrations, and need to be included when estimating effects of PAHs in marine benthic communities. Copyright © 2013 Elsevier B.V. All rights reserved.
Prospects for the Comparative Study of International Migration using quasi-longitudinal micro-data
Liu, Mao-Mei; Creighton, Mathew J.; Riosmena, Fernando; Baizán Mun͂oz, Pau
2017-01-01
BACKGROUND Longitudinal micro-level data about international migration behavior are notoriously difficult to collect, but data collection efforts have become more frequent in recent years. Comparative research of the patterns and processes of international migration, however, remains quite rare, especially that which compares across regions. OBJECTIVE We highlight the promises and difficulties of comparative international migration research, by offering a detailed comparison of two prominent data collection efforts. METHODS We systematically review existing sources of longitudinal and quasi-longitudinal individual-level and household-level data of international migration. We then compare two widely-used data sources: the Mexican Migration Project (MMP) and the Migration between Africa and Europe project (MAFE). RESULTS Data collection efforts are increasingly diverse, yet public accessibility of data remains limited. Also, comparability of data collected across settings can be complicated. In our MMP-MAFE analysis, we show some ways in which comparability can be achieved. CONCLUSIONS A primary roadblock to international comparative research is that, with some exceptions, the public accessibility of data remains low. Even when data is public and surveys are modeled after one another, comparability is not easy due to necessary trade-offs in adapting surveys to local settings and to developments in the field. CONTRIBUTION We demonstrate that, despite great strides in collecting quasi-longitudinal data of international migration, data accessibility still hinders the study of migration. With regards to comparability, our article provides important lessons for future data collection and analysis efforts that could improve comparability and thus advance understanding of the complex dynamics of international migration. PMID:29276429
Alhans, Ruby; Singh, Anukriti; Singhal, Chaitali; Narang, Jagriti; Wadhwa, Shikha; Mathur, Ashish
2018-09-01
In the present work, a comparative study was performed between single-walled carbon nanotubes and multi-walled carbon nanotubes coated gold printed circuit board electrodes for glucose detection. Various characterization techniques were demonstrated in order to compare the modified electrodes viz. cyclic voltammetry, electrochemical impedance spectroscopy and chrono-amperometry. Results revealed that single-walled carbon nanotubes outperformed multi-walled carbon nanotubes and proved to be a better sensing interface for glucose detection. The single-walled carbon nanotubes coated gold printed circuit board electrodes showed a wide linear sensing range (1 mM to 100 mM) with detection limit of 0.1 mM with response time of 5 s while multi-walled carbon nanotubes coated printed circuit board gold electrodes showed linear sensing range (1 mM to 100 mM) with detection limit of 0.1 mM with response time of 5 s. This work provided low cost sensors with enhanced sensitivity, fast response time and reliable results for glucose detection which increased the affordability of such tests in remote areas. In addition, the comparative results confirmed that single-walled carbon nanotubes modified electrodes can be exploited for better amplification signal as compared to multi-walled carbon nanotubes. Copyright © 2018. Published by Elsevier B.V.
Lorenzen, Emma; Follmann, Frank; Secher, Jan O; Goericke-Pesch, Sandra; Hansen, Mette S; Zakariassen, Hannah; Olsen, Anja W; Andersen, Peter; Jungersen, Gregers; Agerholm, Jørgen S
2017-06-01
Advanced animal models, such as minipigs, are needed for the development of a globally requested human Chlamydia vaccine. Previous studies have shown that vaginal inoculation of sexually mature Göttingen minipigs with Chlamydia trachomatis resulted in an infection lasting only 3-5 days. The aim of this study was to evaluate the effect of targeting the upper porcine genital tract by transcervical and transabdominal intrauterine inoculation, compared to previously performed vaginal inoculation. Furthermore, we investigated the effect of the hormonal cycle, estrus vs. diestrus, on the establishment of a C. trachomatis infection in the minipig. Targeting the upper genital tract (transcervical inoculation) resulted in a longer lasting infection (at least 7 days) compared to vaginal inoculation (3-5 days). When comparing intrauterine inoculation during estrus and diestrus, inoculation during diestrus resulted in a longer lasting infection (at least 10 days) compared to estrus (3-5 days). Furthermore, we found a significant C. trachomatis specific IFN-γ response in pigs inoculated during estrus correlating with the accelerated clearance of infection in these pigs. These findings suggest that for implementation of an optimal model of C. trachomatis in minipigs, inoculation should bypass the cervix and preferable be performed during diestrus. Copyright © 2017 The Author(s). Published by Elsevier Masson SAS.. All rights reserved.
[Abnormal cervicovaginal cytology in women with rheumatoid arthritis].
Mercado, Ulises
2010-02-01
Patients with rheumatoid arthritis (RA) are at increased risk of infections and cancer. A link between RA and abnormal cervicovaginal cytology has rarely been reported. The aim of this study was to review cervicovaginal cytology results in women with RA and compare them with a control population. Sexual behavior also was investigated. Cervicovaginal cytology results of 95 women with RA were compared to those of a control population of 1,719 women attending at the same hospital and followed until June 2009. Records of RA patients were reviewed to obtain clinical data, particularly sexual behavior. Of 95 RA patients, 13/95 had an abnormal cervicovaginal cytology result, compared with 120/1,719 controls. Twelve/13 had squamous intraepithelial lesions (SIL), compared with 27/120 controls. There was no significant difference in sexual partners between women with RA and controls. Women with RA without abnormal cervicovaginal cytology had less sexual partners than those with RA and abnormal cytology. Two women with RA and abnormal cervicovaginal cytology had a history of condylomata and herpes genital. Three/13 women with RA developed abnormal cervicovaginal cytology after 12 to 36 months initiating their illness. None from them had ever received immunosuppressants. Women with RA have an increased prevalence of abnormal cervical cytology, compared with a control population. It may be related to chronic inflammatory disease and sexual behavior.
Visual Representations of Texture
1988-12-15
mm I I I In o,. ITY CkASISIFICATION OF THIS G , - - -REPORT DOCUMENTATION PAGE la. REPORT SECURITY CLASSIFICATION b . RESTRICTIVE MARKINGS ,ij...experiments investigating the interaction of size and contrast in texture segregation,( b ) compared our experimental results with the calculated outputs of a M...investigating the interaction of size and contrast in texture segregation, ( b ) compared our experimental results with the calculated outputs of a 2D
Comparison of iSTAT and EPOC Blood Analyzers
2017-10-25
requires accurate blood analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared... analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared gold standard laboratory...temperatures for either device can result in spurious results, particularly for blood gases. 2.0 BACKGROUND Blood analysis is a critical aspect of
Modeling of ESD events from polymeric surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfeifer, Kent Bryant
2014-03-01
Transient electrostatic discharge (ESD) events are studied to assemble a predictive model of discharge from polymer surfaces. An analog circuit simulation is produced and its response is compared to various literature sources to explore its capabilities and limitations. Results suggest that polymer ESD events can be predicted to within an order of magnitude. These results compare well to empirical findings from other sources having similar reproducibility.
The sensitivity of ecosystem service models to choices of input data and spatial resolution
Kenneth J. Bagstad; Erika Cohen; Zachary H. Ancona; Steven. G. McNulty; Ge Sun
2018-01-01
Although ecosystem service (ES) modeling has progressed rapidly in the last 10â15 years, comparative studies on data and model selection effects have become more common only recently. Such studies have drawn mixed conclusions about whether different data and model choices yield divergent results. In this study, we compared the results of different models to address...
2010-09-01
is delineated in upper third in 2006 image. .............................................................................. 23 Figure 19. NDVI ...values are compared for SPOT imagery from 29 May 2006 and 24 August 2006. Fire areas with reduced NDVI from Malpais fire are clearly seen on both sides...results comparing vegetation type and normalized difference vegetation index ( NDVI ), and (4) presents initial results from the groundwater flow field
Walmsley, Christopher W; McCurry, Matthew R; Clausen, Phillip D; McHenry, Colin R
2013-01-01
Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be 'reasonable' are often assumed to have little influence on the results and their interpretation. HERE WE REPORT AN EXTENSIVE SENSITIVITY ANALYSIS WHERE HIGH RESOLUTION FINITE ELEMENT (FE) MODELS OF MANDIBLES FROM SEVEN SPECIES OF CROCODILE WERE ANALYSED UNDER LOADS TYPICAL FOR COMPARATIVE ANALYSIS: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results.
Chung, Kyu Sung; Ha, Jeong Ku; Yeom, Cheol Hyun; Ra, Ho Jong; Jang, Ho Su; Choi, Seung Hyuk; Kim, Jin Goo
2015-10-01
To compare the clinical and radiologic results of partial meniscectomy with those of refixation in patients with medial meniscus posterior root tears (MMPRTs) at a minimum 5-year follow-up. Between 2005 and 2009, patients with MMPRTs who had been followed up for at least 5 years after a partial meniscectomy (group M, n = 20) or pullout repair (group R, n = 37) were recruited. The mean follow-up duration was 67.5 months in group M and 72.0 months in group R. Clinical assessments, including the Lysholm score and International Knee Documentation Committee (IKDC) Subjective Knee Form score, and radiographic assessments, including the Kellgren-Lawrence (K-L) grade and medial joint space width, were evaluated preoperatively and at final follow-up. We compared the preoperative results with the final results in each group, and we compared the final results of groups M and R. Five-year survival rates were also evaluated. The mean Lysholm score (P = .039) and IKDC score (P = .037) improved significantly. However, the width of the medial joint space (P < .001) and K-L grade (P < .001) worsened significantly in both groups. When we compared the final results, group R had significantly better Lysholm scores (P = .002) and IKDC scores (P < .001) than group M. Group R showed less K-L grade progression (P = .005) and less medial joint space narrowing (P < .001) than group M. The rate of conversion to total knee arthroplasty was 35% in group M, whereas there was no conversion to total knee arthroplasty in group R. The 5-year survival rates in groups M and R were 75% and 100%, respectively (P < .001). For MMPRTs, refixation was more effective than partial meniscectomy in terms of the clinical and radiologic outcomes and survival for at least 5 years' follow-up. Refixation slowed the progression of arthritic changes compared with partial meniscectomy, although it did not prevent the progression of arthrosis completely. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
McCurry, Matthew R.; Clausen, Phillip D.; McHenry, Colin R.
2013-01-01
Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be ‘reasonable’ are often assumed to have little influence on the results and their interpretation. Here we report an extensive sensitivity analysis where high resolution finite element (FE) models of mandibles from seven species of crocodile were analysed under loads typical for comparative analysis: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results. PMID:24255817
Marquass, Bastian; Schulz, Ronny; Hepp, Pierre; Zscharnack, Matthias; Aigner, Thomas; Schmidt, Stefanie; Stein, Frank; Richter, Robert; Osterhoff, Georg; Aust, Gabriele; Josten, Christoph; Bader, Augustinus
2011-07-01
The use of predifferentiated mesenchymal stem cells (MSC) leads to better histological results compared with undifferentiated MSC in sheep. This raises the need for a longer term follow-up study and comparison with a clinically established method. We hypothesized that chondrogenic in vitro predifferentiation of autologous MSC embedded in a collagen I hydrogel leads to better structural repair of a chronic osteochondral defect in an ovine stifle joint after 1 year. We further hypothesized that resulting histological results would be comparable with those of chondrocyte-seeded matrix-associated autologous chondrocyte transplantation (MACT). Controlled laboratory study. Predifferentiation period of ovine MSC within collagen gel in vitro was defined by assessment of several cellular and molecular biological parameters. For the animal study, 2 osteochondral lesions (7-mm diameter) were created at the medial femoral condyles of the hind legs in 9 sheep. Implantation of MSC gels was performed 6 weeks after defect creation. Thirty-six defects were divided into 4 treatment groups: (1) chondrogenically predifferentiated MSC gels (pre-MSC gels), (2) undifferentiated MSC gels (un-MSC gels), (3) MACT gels, and (4) untreated controls (UC). Histological, immunohistochemical, and radiological evaluations followed after 12 months. After 12 months in vivo, pre-MSC gels showed significantly better histological outcome compared with un-MSC gels and UC. Compared with MACT gels, the overall scores were higher for O'Driscoll and International Cartilage Repair Society (ICRS). The repair tissue of the pre-MSC group showed immunohistochemical detection of interzonal collagen type II staining. Radiological evaluation supported superior bonding of pre-MSC gels to perilesional native cartilage. Compared with previous work by our group, no degradation of the repair tissue between 6 and 12 months in vivo, particularly in pre-MSC gels, was observed. Repair of chronic osteochondral defects with collagen hydrogels composed of chondrogenically predifferentiated MSC shows no signs of degradation after 1 year in vivo. In addition, pre-MSC gels lead to partially superior histological results compared with articular chondrocytes. The results suggest an encouraging method for future treatment of focal osteochondral defects without donor site morbidity by harvesting articular chondrocytes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucas, Robert G.; Mendon, Vrushali V.; Goel, Supriya
2012-06-01
The 2009 and 2012 International Energy Conservation Codes (IECC) require a substantial improvement in energy efficiency compared to the 2006 IECC. This report averages the energy use savings for a typical new residential dwelling unit based on the 2009 and 2012 IECC compared to the 2006 IECC. Results are reported by the eight climate zones in the IECC and for the national average.
ERIC Educational Resources Information Center
Ward, Jacqueline M.
2011-01-01
Traditional education (TE) largely uses a standardized (SbE) approach while alternatives (nTE) tend to more of a competency (CbE), or student-centered approach. This comparative analysis examines essential aspects of such pedagogies in determining the effectiveness of schooling systems in meeting the Whole Child Initiative (Souza, 1999; Carter et…
Lin, Michael F.; Deoras, Ameya N.; Rasmussen, Matthew D.; Kellis, Manolis
2008-01-01
Comparative genomics of multiple related species is a powerful methodology for the discovery of functional genomic elements, and its power should increase with the number of species compared. Here, we use 12 Drosophila genomes to study the power of comparative genomics metrics to distinguish between protein-coding and non-coding regions. First, we study the relative power of different comparative metrics and their relationship to single-species metrics. We find that even relatively simple multi-species metrics robustly outperform advanced single-species metrics, especially for shorter exons (≤240 nt), which are common in animal genomes. Moreover, the two capture largely independent features of protein-coding genes, with different sensitivity/specificity trade-offs, such that their combinations lead to even greater discriminatory power. In addition, we study how discovery power scales with the number and phylogenetic distance of the genomes compared. We find that species at a broad range of distances are comparably effective informants for pairwise comparative gene identification, but that these are surpassed by multi-species comparisons at similar evolutionary divergence. In particular, while pairwise discovery power plateaued at larger distances and never outperformed the most advanced single-species metrics, multi-species comparisons continued to benefit even from the most distant species with no apparent saturation. Last, we find that genes in functional categories typically considered fast-evolving can nonetheless be recovered at very high rates using comparative methods. Our results have implications for comparative genomics analyses in any species, including the human. PMID:18421375
Reconstruction of a composite comparative map composed of ten legume genomes.
Lee, Chaeyoung; Yu, Dongwoon; Choi, Hong-Kyu; Kim, Ryan W
2017-01-01
The Fabaceae (legume family) is the third largest and the second of agricultural importance among flowering plant groups. In this study, we report the reconstruction of a composite comparative map composed of ten legume genomes, including seven species from the galegoid clade ( Medicago truncatula , Medicago sativa , Lens culinaris, Pisum sativum , Lotus japonicus , Cicer arietinum , Vicia faba ) and three species from the phaseoloid clade ( Vigna radiata , Phaseolus vulgaris , Glycine max ). To accomplish this comparison, a total of 209 cross-species gene-derived markers were employed. The comparative analysis resulted in a single extensive genetic/genomic network composed of 93 chromosomes or linkage groups, from which 110 synteny blocks and other evolutionary events (e.g., 13 inversions) were identified. This comparative map also allowed us to deduce several large scale evolutionary events, such as chromosome fusion/fission, with which might explain differences in chromosome numbers among compared species or between the two clades. As a result, useful properties of cross-species genic markers were re-verified as an efficient tool for cross-species translation of genomic information, and similar approaches, combined with a high throughput bioinformatic marker design program, should be effective for applying the knowledge of trait-associated genes to other important crop species for breeding purposes. Here, we provide a basic comparative framework for the ten legume species, and expect to be usefully applied towards the crop improvement in legume breeding.
An evaluation of the SD Bioline HIV/syphilis duo test.
Holden, Jeffrey; Goheen, Joshua; Jett-Goheen, Mary; Barnes, Mathilda; Hsieh, Yu-Hsiang; Gaydos, Charlotte A
2018-01-01
Many health agencies now recommend routine HIV and syphilis testing for pregnant women and most-at-risk populations such as men who have sex with men. With the increased availability of highly sensitive, low cost rapid point-of-care tests, the ability to meet those recommendations has increased, granting wider access to quick and accurate diagnoses. Using blood specimens collected from a Baltimore City Health Department (BCHD) sexually transmitted infection clinic, we evaluated the SD Bioline HIV/Syphilis Duo, a rapid test that simultaneously detects antibodies to HIV and syphilis and has the potential to further benefit clinics and patients by reducing costs, testing complexity, and patient wait times. SD DUO HIV sensitivity and specificity, when compared to BCHD results, were 91.7 and 99.5%, respectively. SD DUO syphilis sensitivity and specificity, when compared to rapid plasma reagin, were 85.7 and 96.8%, respectively, and 69.7 and 99.7%, respectively, when compared to Treponema pallidum particle agglutination (TPPA). SD DUO syphilis sensitivity and specificity, when compared to a traditional screening algorithm, improved to 92.3 and 100%, respectively, and improved to 72.9 and 99.7%, respectively, when compared to a reverse screening algorithm. The HIV component of the SD DUO performed moderately well. However, results for the SD DUO syphilis component, when compared to TPPA, support the need for further testing and assessment.
Hoekman, Berend; Breitling, Rainer; Suits, Frank; Bischoff, Rainer; Horvatovich, Peter
2012-01-01
Data processing forms an integral part of biomarker discovery and contributes significantly to the ultimate result. To compare and evaluate various publicly available open source label-free data processing workflows, we developed msCompare, a modular framework that allows the arbitrary combination of different feature detection/quantification and alignment/matching algorithms in conjunction with a novel scoring method to evaluate their overall performance. We used msCompare to assess the performance of workflows built from modules of publicly available data processing packages such as SuperHirn, OpenMS, and MZmine and our in-house developed modules on peptide-spiked urine and trypsin-digested cerebrospinal fluid (CSF) samples. We found that the quality of results varied greatly among workflows, and interestingly, heterogeneous combinations of algorithms often performed better than the homogenous workflows. Our scoring method showed that the union of feature matrices of different workflows outperformed the original homogenous workflows in some cases. msCompare is open source software (https://trac.nbic.nl/mscompare), and we provide a web-based data processing service for our framework by integration into the Galaxy server of the Netherlands Bioinformatics Center (http://galaxy.nbic.nl/galaxy) to allow scientists to determine which combination of modules provides the most accurate processing for their particular LC-MS data sets. PMID:22318370
Comparative evaluation of power factor impovement techniques for squirrel cage induction motors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spee, R.; Wallace, A.K.
1992-04-01
This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less
Enea, Violeta; Dafinoiu, Ion; Bogdan, Georgiana; Matei, Carmen
2015-01-01
Most of the studies concerning nonsuicidal self-injury behaviors of persons deprived of liberty were on female participants. This cross-sectional comparative study compared the levels of death anxiety, pain catastrophizing, dissociative experiences, and state-trait anger among male inmates with nonsuicidal self-injury behaviors and noninjuring controls. The results indicated high levels of death anxiety, dissociation, and pain catastrophizing in both groups of participants and the absence of significant differences between the groups. The implications of the results suggest the need of taking into consideration these variables in the behavior management plans used with inmates who engage in self-injurious behavior. PMID:26186948
First-principles calculations of Ti and O NMR chemical shift tensors in ferroelectric perovskites
NASA Astrophysics Data System (ADS)
Pechkis, Daniel; Walter, Eric; Krakauer, Henry
2011-03-01
Complementary chemical shift calculations were carried out with embedded clusters, using quantum chemistry methods, and with periodic boundary conditions, using the GIPAW approach within the Quantum Espresso package. Compared to oxygen chemical shifts, δ̂ (O), cluster calculations for δ̂ (Ti) were found to be more sensitive to size effects, termination, and choice of gaussian-type atomic basis set, while GIPAW results were found to be more sensitive to the pseudopotential construction. The two approaches complemented each other in optimizing these factors. We show that the two approaches yield comparable chemical shifts for suitably converged simulations, and results are compared with available experimental measurements. Supported by ONR.
Comparing Interrater reliability between eye examination and eye self-examination 1
de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio
2017-01-01
Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269
Arias, R P; Unruh-Snyder, L J; Scholljegerdes, E J; Baird, A N; Johnson, K D; Buckmaster, D; Lemenager, R P; Lake, S L
2012-10-01
Two experiments were conducted to evaluate the effects of feeding corn modified wet distillers grain plus solubles (MWDGS) co-ensiled with direct-cut forage (DC) to beef steers, on feedlot performance and total tract digestibility. In Exp. 1, sixty-four crossbred Angus steers (n = 64; 329 ± 43 kg) were blocked by BW and randomly assigned to 1 of 4 dietary treatments: 1) corn-silage and soybean meal (CON), 2) DC co-ensiled with MWDGS (CO-EN), 3) haylage mixed with MWDGS at feeding (H+WDG), and 4) haylage mixed with dry distillers grains plus solubles at feeding (H+DDG). Steers were harvested when they reached an endpoint of 1.1 cm of 12th-rib back fat. In Exp. 2, four ruminally cannulated beef steers (initial BW = 556 ± 31 kg) were used in a 4 × 4 Latin square to evaluate digestibility of diets used in Exp. 1. Experimental periods were 14 d in length with 10 d for diet adaptation and 4 d for sample collection. Three linear orthogonal contrasts were used to compare effects of 1) CON vs. diets containing distillers grains (DGD), 2) CO-EN vs. diets where distillers grains were mixed at feeding (MIX), and 3) H+WDG vs. H+DDG. In Exp. 1, DMI was less (P < 0.001) for steers fed CON compared with those fed DGD and greatest (P < 0.001) for steers fed CO-EN compared with MIX. Corn-silage- and soybean-meal-fed steers had more days on feed than those fed DGD (P = 0.001). Body weight gain (P = 0.02) was greater for CO-EN compared with MIX. Fat thickness at the 12th and 13th ribs was greater (P = 0.03) for DGD steers compared with CON steers. Hot carcass weight was greater (P = 0.03) for steers fed CO-EN compared with those fed MIX. Steers fed CON resulted in greater marbling scores (P = 0.01) compared DGD-fed steers. Longissimus muscle area was greater (P = 0.01) for CON-fed steers compared with all other treatments. In Exp. 2, no differences (P > 0.10) in DM, OM, or N intakes were observed. Apparent total tract DM (P = 0.01) and N (P = 0.02) digestibility were greatest in steers fed CON compared with all others. Steers fed DGD had less (P = 0.02) rumen NH(3) concentrations compared with CON. The CON diet resulted in greater molar concentrations of VFA (P = 0.03) and decreased acetate to propionate ratio (P = 0.03) compared with all DGD. These data suggest that feeding MWDGS co-ensiled with direct-cut forage results in reduced diet digestibility but equal or greater feedlot performance and similar carcass and characteristics when compared with a corn diet supplemented with soybean meal and diets where MWDGS and DDGS were added at the mixer.
Grachev, I D; Apkarian, A V
2000-12-01
We recently presented results in an in vivo study of human brain chemistry in 'physiologic' anxiety, i.e., the anxiety of normal everyday life. Normal subjects with high anxiety demonstrated increased concentration of chemicals in orbital frontal cortex (OFC) as compared to lower anxiety. In a separate study of aging we demonstrated a decrease of total chemical concentration in OFC of middle-aged subjects, as compared with younger age. This brain region also showed gender dependence; men demonstrating decreased chemical concentration compared to women. We hypothesized that these sex- and age-dependent differences in OFC chemistry changes are a result of anxiety effects on this brain region. In the present study we examined these sex- and age-differential regional brain chemistry changes (as identified by localized in vivo proton magnetic resonance spectroscopy [1H-MRS]) in relation to the state-trait-anxiety (as measured by the State-Trait Anxiety Inventory) in 35 healthy subjects. The concentrations for all nine chemicals of 1H-MRS spectra were measured relative to creatine across multiple brain regions, including OFC in the left hemisphere. Analysis of variance showed anxiety-specific effects on chemical concentration changes in OFC, which were different for both sexes and age groups. Male subjects showed larger effect of anxiety on OFC chemistry as compared to females when the same sex high-anxiety subjects were compared to lower anxiety. Similarly, middle-aged subjects showed larger effect of anxiety on OFC chemistry as compared to younger age when the same age subjects with high anxiety were compared to lower anxiety. Largest effect of anxiety on OFC chemistry was due to changes of N-Acetyl aspartate. The results indicate that the state-trait anxiety has sex- and age-differential patterns on OFC chemistry in healthy humans, providing new information about the neurobiological roots of anxiety.
Gasior, Pawel; Cheng, Yanping; Valencia, Andres F; McGregor, Jenn; Conditt, Gerard B; Kaluza, Grzegorz L; Granada, Juan F
2017-05-01
A polymer-free peripheral paclitaxel-eluting stent (PES, Zilver PTX, Cook, IN) has shown to improve vessel patency after superficial femoral angioplasty. A new-generation fluoropolymer-based PES (FP-PES; Eluvia, Boston Scientific, MA) displaying more controlled and sustained paclitaxel delivery promise to improve the clinical outcomes of first-generation PES. We sought to compare the biological effect of paclitaxel delivered by 2 different stent-coating technologies (fluoropolymer-based versus polymer-free) on neointimal proliferation and healing response in the familial hypercholesterolemic swine model of femoral restenosis. The biological efficacy of clinically available FP-PES (n=12) and PES (n=12) was compared against a bare metal stent control (n=12; Innova, Boston Scientific, MA) after implantation in the femoral arteries of 18 familial hypercholesterolemic swine. Longitudinal quantitative vascular angiography and optical coherence tomography were performed at baseline and at 30 and 90 days. Histological evaluation was performed at 90 days. Ninety-day quantitative vascular angiography results showed a lower percent diameter stenosis for FP-PES (38.78% [31.27-47.66]) compared with PES (54.16% [42.60-61.97]) and bare metal stent (74.52% [47.23-100.00]; P <0.001). Ninety-day optical coherence tomography results demonstrated significantly lower neointimal area in FP-PES (8.01 mm 2 [7.65-9.21]) compared with PES (10.95 mm 2 [9.64-12.46]) and bare metal stent (13.83 mm 2 [11.53-17.03]; P <0.001). Histological evaluation showed larger lumen areas and evidence of higher biological activity (smooth muscle cell loss and fibrin deposition) in the FP-PES compared with PES and bare metal stent. In the familial hypercholesterolemic swine model of femoral restenosis, the implantation of an FP-PES resulted in lower levels of neointimal proliferation and sustained biological effect ≤90 days compared with a polymer-free stent-based approach. © 2017 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Jeremy P.; Murphy, James D.; Hanlon, Alexandra L.
2014-03-15
Purpose: Concerns have been raised about the potential for worse treatment outcomes because of dosimetric inaccuracies related to tumor motion and increased toxicity caused by the spread of low-dose radiation to normal tissues in patients with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). We therefore performed a population-based comparative effectiveness analysis of IMRT, conventional 3-dimensional conformal radiation therapy (3D-CRT), and 2-dimensional radiation therapy (2D-RT) in stage III NSCLC. Methods and Materials: We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare database to identify a cohort of patients diagnosed with stage III NSCLC frommore » 2002 to 2009 treated with IMRT, 3D-CRT, or 2D-RT. Using Cox regression and propensity score matching, we compared survival and toxicities of these treatments. Results: The proportion of patients treated with IMRT increased from 2% in 2002 to 25% in 2009, and the use of 2D-RT decreased from 32% to 3%. In univariate analysis, IMRT was associated with improved overall survival (OS) (hazard ratio [HR] 0.90, P=.02) and cancer-specific survival (CSS) (HR 0.89, P=.02). After controlling for confounders, IMRT was associated with similar OS (HR 0.94, P=.23) and CSS (HR 0.94, P=.28) compared with 3D-CRT. Both techniques had superior OS compared with 2D-RT. IMRT was associated with similar toxicity risks on multivariate analysis compared with 3D-CRT. Propensity score matched model results were similar to those from adjusted models. Conclusions: In this population-based analysis, IMRT for stage III NSCLC was associated with similar OS and CSS and maintained similar toxicity risks compared with 3D-CRT.« less
López, Vladimir; Villar, Margarita; Queirós, João; Vicente, Joaquín; Mateos-Hernández, Lourdes; Díez-Delgado, Iratxe; Contreras, Marinela; Alves, Paulo C.; Alberdi, Pilar; Gortázar, Christian; de la Fuente, José
2016-01-01
Mycobacteria of the Mycobacterium tuberculosis complex (MTBC) greatly impact human and animal health worldwide. The mycobacterial life cycle is complex, and the mechanisms resulting in pathogen infection and survival in host cells are not fully understood. Eurasian wild boar (Sus scrofa) are natural reservoir hosts for MTBC and a model for mycobacterial infection and tuberculosis (TB). In the wild boar TB model, mycobacterial infection affects the expression of innate and adaptive immune response genes in mandibular lymph nodes and oropharyngeal tonsils, and biomarkers have been proposed as correlates with resistance to natural infection. However, the mechanisms used by mycobacteria to manipulate host immune response are not fully characterized. Our hypothesis is that the immune system proteins under-represented in infected animals, when compared to uninfected controls, are used by mycobacteria to guarantee pathogen infection and transmission. To address this hypothesis, a comparative proteomics approach was used to compare host response between uninfected (TB-) and M. bovis-infected young (TB+) and adult animals with different infection status [TB lesions localized in the head (TB+) or affecting multiple organs (TB++)]. The results identified host immune system proteins that play an important role in host response to mycobacteria. Calcium binding protein A9, Heme peroxidase, Lactotransferrin, Cathelicidin and Peptidoglycan-recognition protein were under-represented in TB+ animals when compared to uninfected TB- controls, but protein levels were higher as infection progressed in TB++ animals when compared to TB- and/or TB+ adult wild boar. MHCI was the only protein over-represented in TB+ adult wild boar when compared to uninfected TB- controls. The results reported here suggest that M. bovis manipulates host immune response by reducing the production of immune system proteins. However, as infection progresses, wild boar immune response recovers to limit pathogen multiplication and promote survival, facilitating pathogen transmission. PMID:27027307
Jankar, Ajit S; Kale, Yogesh; Kangane, Suresh; Ambekar, Anand; Sinha, Manish; Chaware, Sachin
2014-02-01
Ceramic veneer fracture has occurred mainly at the incisal edge of the veneer because of greater stress. This study compares and evaluates the fracture resistance ceramic veneers with three different incisal preparations. 15 human permanent maxillary central incisor extracted were selected which were divided into three groups of 5 each having a different Incial design Preparation. Group 1: No Incisal reduction with facio- incisal bevel, Group 2 : 1 mm incisal reduction with butt joint, Group 3 : 1 mm incisal reduction with 1 mm height of Palatal chamfer. It was found that Group III had greater fracture resistance as compared to Group I and Group II. Group I had least fracture resistance as compared to Group II and III. Group II had greater fracture resistance as compared to Group I but less than Group III. Ceramic veneer with 1mm incisal reduction with 1mm height of palatal chamfer showed highest fracture resistance as compared to 1mm incisal reduction with butt joint and no incisal reduction with facial-incisal bevel, in order to achieve better esthetic and functional results. The palatal chamfer margin results in preservation of some peripheral enamel layer, which eliminates the micro leakage at the palatal margin-restoration interface and also effectively counteracting shear stress. This design provides a definite seat for cementation. How to cite the article: Jankar AS, Kale Y, Kangane S, Ambekar A, Sinha M, Chaware S. Comparative evaluation of fracture resistance of Ceramic Veneer with three different incisal design preparations - An In-vitro Study. J Int Oral Health 2014;6(1):48-54.
A matching framework to improve causal inference in interrupted time-series analysis.
Linden, Ariel
2018-04-01
Interrupted time-series analysis (ITSA) is a popular evaluation methodology in which a single treatment unit's outcome is studied over time and the intervention is expected to "interrupt" the level and/or trend of the outcome, subsequent to its introduction. When ITSA is implemented without a comparison group, the internal validity may be quite poor. Therefore, adding a comparable control group to serve as the counterfactual is always preferred. This paper introduces a novel matching framework, ITSAMATCH, to create a comparable control group by matching directly on covariates and then use these matches in the outcomes model. We evaluate the effect of California's Proposition 99 (passed in 1988) for reducing cigarette sales, by comparing California to other states not exposed to smoking reduction initiatives. We compare ITSAMATCH results to 2 commonly used matching approaches, synthetic controls (SYNTH), and regression adjustment; SYNTH reweights nontreated units to make them comparable to the treated unit, and regression adjusts covariates directly. Methods are compared by assessing covariate balance and treatment effects. Both ITSAMATCH and SYNTH achieved covariate balance and estimated similar treatment effects. The regression model found no treatment effect and produced inconsistent covariate adjustment. While the matching framework achieved results comparable to SYNTH, it has the advantage of being technically less complicated, while producing statistical estimates that are straightforward to interpret. Conversely, regression adjustment may "adjust away" a treatment effect. Given its advantages, ITSAMATCH should be considered as a primary approach for evaluating treatment effects in multiple-group time-series analysis. © 2017 John Wiley & Sons, Ltd.
Kauf, Teresa L; Prabhu, Vimalanand S; Medic, Goran; Borse, Rebekah H; Miller, Benjamin; Gaultney, Jennifer; Sen, Shuvayu S; Basu, Anirban
2017-04-28
A challenge in the empiric treatment of complicated urinary tract infection (cUTI) is identifying the initial appropriate antibiotic therapy (IAAT), which is associated with reduced length of stay and mortality compared with initial inappropriate antibiotic therapy (IIAT). We evaluated the cost-effectiveness of ceftolozane/tazobactam compared with piperacillin/tazobactam (one of the standard of care antibiotics), for the treatment of hospitalized patients with cUTI. A decision-analytic Monte Carlo simulation model was developed to compare the costs and effectiveness of empiric treatment with either ceftolozane/tazobactam or piperacillin/tazobactam in hospitalized adult patients with cUTI infected with Gram-negative pathogens in the US. The model applies the baseline prevalence of resistance as reported by national in-vitro surveillance data. In a cohort of 1000 patients, treatment with ceftolozane/tazobactam resulted in higher total costs compared with piperacillin/tazobactam ($36,413 /patient vs. $36,028/patient, respectively), greater quality-adjusted life years (QALYs) (9.19/patient vs. 9.13/patient, respectively) and an incremental cost-effectiveness ratio (ICER) of $6128/QALY. Ceftolozane/tazobactam remained cost-effective at a willingness to pay of $100,000 per QALY compared to piperacillin/tazobactam over a range of input parameter values during one-way and probabilistic sensitivity analysis. Model results show that ceftolozane/tazobactam is likely to be cost-effective compared with piperacillin/tazobactam for the empiric treatment of hospitalized cUTI patients in the United States.
Performance and energy systems contributions during upper-body sprint interval exercise
Franchini, Emerson; Takito, Monica Yuri; Dal’Molin Kiss, Maria Augusta Peduti
2016-01-01
The main purpose of this study was to investigate the performance and energy systems contribution during four upper-body Wingate tests interspersed by 3-min intervals. Fourteen well-trained male adult Judo athletes voluntarily took part in the present study. These athletes were from state to national level, were in their competitive period, but not engaged in any weight loss procedure. Energy systems contributions were estimated using oxygen uptake and blood lactate measurements. The main results indicated that there was higher glycolytic contribution compared to oxidative (P<0.001) during bout 1, but lower glycolytic contribution was observed compared to the phosphagen system (adenosine triphosphate-creatine phosphate, ATP-PCr) contribution during bout 3 (P<0.001), lower glycolytic contribution compared to oxidative and ATP-PCr (P<0.001 for both comparisons) contributions during bout 4 and lower oxidative compared to ATP-PCr during bout 4 (P=0.040). For the energy system contribution across Wingate bouts, the ATP-PCr contribution during bout 1 was lower than that observed during bout 4 (P=0.005), and the glycolytic system presented higher percentage contribution in the first bout compared to the third and fourth bouts (P<0.001 for both comparisons), and higher percentage participation in the second compared to the fourth bout (P<0.001). These results suggest that absolute oxidative and ATP-PCr participations were kept constant across Wingate tests, but there was an increase in relative participation of ATP-PCr in bout 4 compared to bout 1, probably due to the partial phosphocreatine resynthesis during intervals and to the decreased glycolytic activity. PMID:28119874
High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.
Miller, Christopher P; Ghorbanhoseini, Mohammad; Ehrlichman, Lauren K; Walley, Kempland C; Ghaheri, Azadeh; Kwon, John Y
2017-06-01
Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest. Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing. The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002). There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs. Level III, comparative study.
Pappas, Evangelos
2007-01-01
The incidence of injury in combat sports has not been adequately reported although it is important to identify the nature and frequency of injuries prior to the implementation of prevention programs. This study compared injury rates treated in Hospital Emergency Departments between different combat sports of boxing, wrestling, and martial arts. A secondary objective described anatomic region and diagnosis of these injuries. Data were obtained on all boxing, wrestling, and martial arts-related injuries that were in the National Electronic Injury Surveillance System database and resulted in Emergency Department visits between 2002 and 2005. Pearson’s chi-square statistics were calculated to compare injury rates for each activity accounting for complex sample design. Martial arts had lower injury rates compared to boxing and wrestling for all diagnoses (p<0.001). Boxing had lower injury rates compared to wrestling for strains/sprains and dislocations. Boxing and wrestling had similar injury rates for concussions. Injury prevention efforts should consider the distribution of injuries and concentrate on preventing strains/sprains in wrestling, concussions in boxing and wrestling, and fractures for all three activities. The findings of the present study do not provide evidence that combat sports have alarmingly high rates of injuries resulting in emergency department visits. Key points Martial arts have lower emergency department injury rates compared to boxing and wrestling. Wrestling has higher strains/sprains and dislocation injury rates compared to boxing. Combat sports do not appear to have higher injury rates compared to non-combat sports. PMID:24198705
Longitudinal comparison study of pressure relief (C-Flex) vs. CPAP in OSA patients.
Dolan, Diana C; Okonkwo, Renata; Gfullner, Florian; Hansbrough, J Randall; Strobel, Richard J; Rosenthal, Leon
2009-03-01
Continuous positive airway pressure (CPAP) devices with the option of flexible pressure delivery (e.g., C-Flex) are thought to provide an improved degree of comfort and result in better therapeutic adherence while maintaining standard CPAP efficacy. The purpose of this study was to compare adherence and subjective measures of comfort between C-Flex and CPAP treatment. The study was an international, multisite, single-blinded study with participants randomized to either C-Flex or CPAP. Participants completed subjective measures of sleepiness and comfort at baseline, and at 30-, 90-, and 180-day follow-ups. Additionally, compliance data were downloaded from the device at each follow-up. Repeated measures analysis of variance was used to assess the effects of treatment. There were 138 men and 46 women (average age of 48 +/- 9.2, average Epworth Sleepiness Scale score of 14.9 +/- 3.6, and average diagnostic apnea/hypopnea index (AHI) of 51.9 +/- 27.7). C-Flex and CPAP groups were comparable on baseline measures, achieved comparable AHI on titration, and had comparable PAP pressure requirements. C-Flex users had comparable average hours of use per night and total nights of use across the study, but had a trend (p < .07) toward achieving greater total hours of utilization. While both groups had comparable decreases in sleepiness, C-Flex users reported on visual analog scales greater comfort (64.3 vs. 57.4; p = .01). The results of this study demonstrated that C-Flex has comparable resolution of respiratory indices and adherence. Furthermore, C-Flex users reported greater mask comfort.
NASA Astrophysics Data System (ADS)
Federico, S.; Avolio, E.; Bellecci, C.; Colacino, M.; Walko, R. L.
2006-03-01
This paper reports preliminary results for a Limited area model Ensemble Prediction System (LEPS), based on RAMS (Regional Atmospheric Modelling System), for eight case studies of moderate-intense precipitation over Calabria, the southernmost tip of the Italian peninsula. LEPS aims to transfer the benefits of a probabilistic forecast from global to regional scales in countries where local orographic forcing is a key factor to force convection. To accomplish this task and to limit computational time in an operational implementation of LEPS, we perform a cluster analysis of ECMWF-EPS runs. Starting from the 51 members that form the ECMWF-EPS we generate five clusters. For each cluster a representative member is selected and used to provide initial and dynamic boundary conditions to RAMS, whose integrations generate LEPS. RAMS runs have 12-km horizontal resolution. To analyze the impact of enhanced horizontal resolution on quantitative precipitation forecasts, LEPS forecasts are compared to a full Brute Force (BF) ensemble. This ensemble is based on RAMS, has 36 km horizontal resolution and is generated by 51 members, nested in each ECMWF-EPS member. LEPS and BF results are compared subjectively and by objective scores. Subjective analysis is based on precipitation and probability maps of case studies whereas objective analysis is made by deterministic and probabilistic scores. Scores and maps are calculated by comparing ensemble precipitation forecasts against reports from the Calabria regional raingauge network. Results show that LEPS provided better rainfall predictions than BF for all case studies selected. This strongly suggests the importance of the enhanced horizontal resolution, compared to ensemble population, for Calabria for these cases. To further explore the impact of local physiographic features on QPF (Quantitative Precipitation Forecasting), LEPS results are also compared with a 6-km horizontal resolution deterministic forecast. Due to local and mesoscale forcing, the high resolution forecast (Hi-Res) has better performance compared to the ensemble mean for rainfall thresholds larger than 10mm but it tends to overestimate precipitation for lower amounts. This yields larger false alarms that have a detrimental effect on objective scores for lower thresholds. To exploit the advantages of a probabilistic forecast compared to a deterministic one, the relation between the ECMWF-EPS 700 hPa geopotential height spread and LEPS performance is analyzed. Results are promising even if additional studies are required.
Stabile, Sueli Aparecida Batista; Evangelista, Dilson Henrique Ramos; Talamonte, Valdely Helena; Lippi, Umberto Gazi; Lopes, Reginaldo Guedes Coelho
2012-01-01
To compare two oncotic cervical cytology techniques, the conventional and the liquid-based cytology, in low risk patients for uterine cervical cancer. Comparative prospective study with 100 patients who came to their annual gynecological exam, and were submitted simultaneously to both techniques. We used the McNemar test, with a significance level of p < 0.05 to compare the results obtained related to adequacy of the smear quality, descriptive diagnosis prevalence, guided biopsy confirmation and histology. Adequacy of the smear was similar for both methods. The quality with squamocolumnar junction in 93% of conventional cytology and in 84% of the liquid-based cytology had statistical significance. As for the diagnosis of atypical cells they were detected in 3% of conventional cytology and in 10% of liquid-based cytology (p = 0.06). Atypical squamous cells of undetermined significance were the most prevalent abnormality. The liquid-based cytology performance was better when compared with colposcopy (guided biopsy), presenting sensitivity of 66.7% and specificity of 100%. There was no cytological and histological concordance for the conventional cytology. Liquid-based cytology had a better performance to diagnose atypical cells and the cytohistological concordance was higher than in the conventional cytology.
Qanungo, Anchal; Aras, Meena Ajay; Chitre, Vidya; Coutinho, Ivy; Rajagopal, Praveen; Mysore, Ashwin
2016-01-01
Purpose: The aim of this in vivo study was to compare the single-step border molding technique using injectable heavy viscosity addition silicone with sectional border molding technique using low fusing impression compound by evaluating the retention of heat cure trial denture bases. Materials and Methods: Ten completely edentulous patients in need of prostheses were included in this study. Two border molding techniques, single-step (Group 1) and sectional (Group 2), were compared for retention. Both border molding techniques were performed in each patient. In both techniques, definitive wash impression was made with light viscosity addition silicone. The final results were analyzed using paired t-test to determine whether significant differences existed between the groups. Results: The t-value (3.031) infers that there was a significant difference between Group 1 and Group 2 (P = 0.014). The retention obtained in Group 2 (mean = 9.05 kgf) was significantly higher than that of Group 1 (mean = 8.26 kgf). Conclusion: Sectional border molding technique proved to be more retentive as compared to single-step border molding although clinically the retention appeared comparable. PMID:27746597
CoCoNUT: an efficient system for the comparison and analysis of genomes
2008-01-01
Background Comparative genomics is the analysis and comparison of genomes from different species. This area of research is driven by the large number of sequenced genomes and heavily relies on efficient algorithms and software to perform pairwise and multiple genome comparisons. Results Most of the software tools available are tailored for one specific task. In contrast, we have developed a novel system CoCoNUT (Computational Comparative geNomics Utility Toolkit) that allows solving several different tasks in a unified framework: (1) finding regions of high similarity among multiple genomic sequences and aligning them, (2) comparing two draft or multi-chromosomal genomes, (3) locating large segmental duplications in large genomic sequences, and (4) mapping cDNA/EST to genomic sequences. Conclusion CoCoNUT is competitive with other software tools w.r.t. the quality of the results. The use of state of the art algorithms and data structures allows CoCoNUT to solve comparative genomics tasks more efficiently than previous tools. With the improved user interface (including an interactive visualization component), CoCoNUT provides a unified, versatile, and easy-to-use software tool for large scale studies in comparative genomics. PMID:19014477
Price and utilisation differences for statins between four countries.
Thai, Loc Phuoc; Vitry, Agnes Isabelle; Moss, John Robert
2018-02-01
Australia, England, France and New Zealand use different policies to regulate their medicines market, which can impact on utilisation and price. To compare the prices and utilisation of statins in Australia, England, France and New Zealand from 2011 to 2013. Utilisation of statins in the four countries was compared using Defined Daily Doses (DDD) per 1000 inhabitants per year. Pairwise Laspeyres and Paasche index comparisons were conducted comparing the price and utilisation of statins. The results showed that the price of statins in New Zealand was the cheapest. The price of statins in Australia was most expensive in 2011 and 2012 but France was more expensive in 2013. There were large differences between the Laspeyres index and Paasche index when comparing the price and utilisation of England with Australia and France. The policies that regulate the New Zealand and England medicines markets were more effective in reducing the price of expensive statins. The relative utilisation of cheaper statins was greatest in England and had a large effect on the differences between the two index results. The pricing policies in Australia have been only partly effective in reducing the price of statins compared to other countries.
NASA Technical Reports Server (NTRS)
Hicks, Yolanda R.; Tacina, M.
2013-01-01
Combustion performance of a Fischer-Tropsch (FT) jet fuel manufactured by Sasol was compared to JP-8 and a 50-50 blend of the two fuels, using the NASA/Woodward 9 point Lean Direct Injector (LDI) in its baseline configuration. The baseline LDI configuration uses 60deg axial air-swirlers, whose vanes generate clockwise swirl, in the streamwise sense. For all cases, the fuel-air equivalence ratio was 0.455, and the combustor inlet pressure and pressure drop were 10-bar and 4 percent. The three inlet temperatures used were 828, 728, and 617 K. The objectives of this experiment were to visually compare JP-8 flames with FT flames for gross features. Specifically, we sought to ascertain in a simple way visible luminosity, sooting, and primary flame length of the FT compared to a standard JP grade fuel. We used color video imaging and high-speed imaging to achieve these goals. The flame color provided a way to qualitatively compare soot formation. The length of the luminous signal measured using the high speed camera allowed an assessment of primary flame length. It was determined that the shortest flames resulted from the FT fuel.
Are batterers different from other criminals? An fMRI study
Verdejo-Román, Juan; Contreras-Rodríguez, Oren; Carmona-Perera, Martina; Pérez-García, Miguel; Hidalgo-Ruzzante, Natalia
2016-01-01
Abstract Intimate partner violence (IPV) is a complex and global phenomenon that requires a multi-perspective analysis. Nevertheless, the number of neuroscientific studies conducted on this issue is scarce as compared with studies of other types of violence, and no neuroimaging studies comparing batterers to other criminals have been conducted. Thus, the main aim of this study was to compare the brain functioning of batterers to that of other criminals when they are exposed to IPV or general violence pictures. An fMRI study was conducted in 21 batterers and 20 other criminals while they observed IPV images (IPVI), general violence images (GVI) and neutral images (NI). Results demonstrated that batterers, compared with other criminals, exhibited a higher activation in the anterior and posterior cingulate cortex and in the middle prefrontal cortex and a decreased activation in the superior prefrontal cortex to IPVI compared to NI. The paired t-test comparison between IPVI and GVI for each group showed engagement of the medial prefrontal cortex, the posterior cingulate and the left angular cortices to IPVI in the batterer group only. These results could have important implications for a better understanding of the IPV phenomenon. PMID:26884544
Smartphone assessment of knee flexion compared to radiographic standards.
Dietz, Matthew J; Sprando, Daniel; Hanselman, Andrew E; Regier, Michael D; Frye, Benjamin M
2017-03-01
Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparative immunoexpression of ICAM-1, TGF-β1 and ki-67 in periapical and residual cysts
Armada, Luciana; dos Santos, Teresa-Cristina; Pires, Fabio-Ramoa
2017-01-01
Background This study compared the immunohistochemical expression of ki-67, transforming growth factor beta 1 (TGF-β1) and intercellular adhesion molecule-1 (ICAM-1) in inflammatory periapical cysts and residual cysts. Material and Methods The study sample was composed by 25 periapical cysts and 25 residual cysts and immunohistochemical reactions were carried out using antibodies directed against ICAM-1, TGF-β1 and ki-67. Clinical, radiological, gross, histological and immunohistochemical data were tabulated for descriptive and comparative analysis using the SPSS software and differences were considered statistically significant when p<0.05%. Results There were no differences between the expression of ICAM-1 (p=0.239) and TGF-β1 (p=0.258) when comparing both groups. Ki-67 labeling index was higher in residual cysts compared to periapical cysts (p=0.017). Conclusions Results from the present study suggest that some specific inflammatory stimuli on residual cysts would modulate their mechanisms of etiopathogenesis, growing and repair. Key words:Periapical cyst, radicular cyst, residual cyst, transforming growth factor beta 1 (TGF-β1), intercellular adhesion molecule 1 (ICAM-1), ki-67. PMID:27918735
Kayataş, Semra; Özkaya, Enis; Api, Murat; Çıkman, Seyhan; Gürbüz, Ayşen; Eser, Ahmet
2017-01-01
Objective: The aim of the present study was to compare female sexual function between women who underwent conventional abdominal or laparoscopic hysterectomy. Materials and Methods: Seventy-seven women who were scheduled to undergo hysterectomy without oophorectomy for benign gynecologic conditions were included in the study. The women were assigned to laparoscopic or open abdominal hysterectomy according to the surgeons preference. Women with endometriosis and symptomatic prolapsus were excluded. Female sexual function scores were obtained before and six months after the operation from each participant by using validated questionnaires. Results: Pre- and postoperative scores of three different quationnaires were found as comparable in the group that underwent laparoscopic hysterectomy (p>0.05). Scores were also found as comparable in the group that underwent laparotomic hysterectomy (p>0.05). Pre- and postoperative values were compared between the two groups and revealed similar results with regard to all three scores (p>0.05). Conclusion: Our data showed comparable pre- and the postoperative scores for the two different hysterectomy techniques. The two groups were also found to have similar pre- and postoperative score values. PMID:28913149
Robotic assisted gastrectomy compared with open resection: a case-matched study.
Caruso, Riccardo; Vicente, Emilio; Quijano, Yolanda; Ielpo, Benedetto; Duran, Hipolito; Diaz, Eduardo; Fabra, Isabel; Ferri, Valentina
2018-05-04
In recent years, increasingly sophisticated tools have allowed for more complex robotic surgery. Robotic gastrectomy, however, is adopted in only a few selected centers. The goals of this study were to examine the adoption of robotic gastrectomy and to compare outcomes between open and robotic gastric resections. This is a case-matched analysis of patients who underwent robotic and open gastric resection performed at Sanchinarro University Hospital, Madrid from November 2011 to February 2017. Patient data were obtained retrospectively. Clinicopathologic characteristics and perioperative and postoperative outcomes were recorded and analyzed. Two groups of demographically similar patients were analyzed: the robotic group (n = 20) and the open surgery group (n = 19). The patient characteristics of the two groups have been compared. Robotic resection resulted in less blood loss, shorter postoperative hospital stay, and a longer operating time. The two groups had similar complication rates. Pathological data were similar for both procedures. Robotic gastrectomy for locally advanced gastric carcinoma is safe, and long-term outcomes are comparable to those patients who underwent open resection. Robotic gastrectomy resulted in a shorter hospital stay, less blood loss and morbidity comparable with the outcomes of open gastrectomy.
Griffin, Darren K; Robertson, Lindsay B; Tempest, Helen G; Vignal, Alain; Fillon, Valérie; Crooijmans, Richard PMA; Groenen, Martien AM; Deryusheva, Svetlana; Gaginskaya, Elena; Carré, Wilfrid; Waddington, David; Talbot, Richard; Völker, Martin; Masabanda, Julio S; Burt, Dave W
2008-01-01
Background Comparative genomics is a powerful means of establishing inter-specific relationships between gene function/location and allows insight into genomic rearrangements, conservation and evolutionary phylogeny. The availability of the complete sequence of the chicken genome has initiated the development of detailed genomic information in other birds including turkey, an agriculturally important species where mapping has hitherto focused on linkage with limited physical information. No molecular study has yet examined conservation of avian microchromosomes, nor differences in copy number variants (CNVs) between birds. Results We present a detailed comparative cytogenetic map between chicken and turkey based on reciprocal chromosome painting and mapping of 338 chicken BACs to turkey metaphases. Two inter-chromosomal changes (both involving centromeres) and three pericentric inversions have been identified between chicken and turkey; and array CGH identified 16 inter-specific CNVs. Conclusion This is the first study to combine the modalities of zoo-FISH and array CGH between different avian species. The first insight into the conservation of microchromosomes, the first comparative cytogenetic map of any bird and the first appraisal of CNVs between birds is provided. Results suggest that avian genomes have remained relatively stable during evolution compared to mammalian equivalents. PMID:18410676
Zhang, Ray; Isakow, Warren; Kollef, Marin H; Scott, Mitchell G
2017-09-01
Due to accuracy concerns, the Food and Drug Administration issued guidances to manufacturers that resulted in Center for Medicare and Medicaid Services stating that the use of meters in critically ill patients is "off-label" and constitutes "high complexity" testing. This is causing significant workflow problems in ICUs nationally. We wished to determine whether real-world accuracy of modern glucose meters is worse in ICU patients compared with non-ICU inpatients. We reviewed glucose results over the preceding 3 years, comparing results from paired glucose meter and central laboratory tests performed within 60 minutes of each other in ICU versus non-ICU settings. Seven ICU and 30 non-ICU wards at a 1,300-bed academic hospital in the United States. A total of 14,763 general medicine/surgery inpatients and 20,970 ICU inpatients. None. Compared meter results with near simultaneously performed laboratory results from the same patient by applying the 2016 U.S. Food and Drug Administration accuracy criteria, determining mean absolute relative difference and examining where paired results fell within the Parkes consensus error grid zones. A higher percentage of glucose meter results from ICUs than from non-ICUs passed 2016 Food and Drug Administration accuracy criteria (p < 10) when comparing meter results with laboratory results. At 1 minute, no meter result from ICUs posed dangerous or significant risk by error grid analysis, whereas at 10 minutes, less than 0.1% of ICU meter results did, which was not statistically different from non-ICU results. Real-world accuracy of modern glucose meters is at least as accurate in the ICU setting as in the non-ICU setting at our institution.
Fischer, Michael A; Avorn, Jerry
2012-10-01
Comparative effectiveness research evaluates the relative effectiveness, safety, and value of competing treatment options in clinically realistic settings. Such evaluations can be methodologically complex and difficult to interpret. There will be a growing need for critical evaluation of comparative effectiveness studies to assess the adequacy of their design and to put new information into a broader context. Equally important, this knowledge will have to be communicated to clinicians in a way that will actually change practice. We identify three challenges to effective dissemination of comparative effectiveness research findings: the difficulty of interpreting comparative effectiveness research data, the need for trusted sources of information, and the challenge of turning research results into clinical action. We suggest that academic detailing-direct outreach education that gives clinicians an accurate and unbiased synthesis of the best evidence for practice in a given clinical area-can translate comparative effectiveness research findings into actions that improve health care decision making and patient outcomes.
Cutting-edge technology for public health workforce training in comparative effectiveness research.
Salinas-Miranda, Abraham A; Nash, Michelle C; Salemi, Jason L; Mbah, Alfred K; Salihu, Hamisu M
2013-06-01
A critical mass of public health practitioners with expertise in analytic techniques and best practices in comparative effectiveness research is needed to fuel informed decisions and improve the quality of health care. The purpose of this case study is to describe the development and formative evaluation of a technology-enhanced comparative effectiveness research learning curriculum and to assess its potential utility to improve core comparative effectiveness research competencies among the public health workforce. Selected public health experts formed a multidisciplinary research collaborative and participated in the development and evaluation of a blended 15-week comprehensive e-comparative effectiveness research training program, which incorporated an array of health informatics technologies. Results indicate that research-based organizations can use a systematic, flexible, and rapid means of instructing their workforce using technology-enhanced authoring tools, learning management systems, survey research software, online communities of practice, and mobile communication for effective and creative comparative effectiveness research training of the public health workforce.
TwiMed: Twitter and PubMed Comparable Corpus of Drugs, Diseases, Symptoms, and Their Relations
Miyao, Yusuke; Collier, Nigel
2017-01-01
Background Work on pharmacovigilance systems using texts from PubMed and Twitter typically target at different elements and use different annotation guidelines resulting in a scenario where there is no comparable set of documents from both Twitter and PubMed annotated in the same manner. Objective This study aimed to provide a comparable corpus of texts from PubMed and Twitter that can be used to study drug reports from these two sources of information, allowing researchers in the area of pharmacovigilance using natural language processing (NLP) to perform experiments to better understand the similarities and differences between drug reports in Twitter and PubMed. Methods We produced a corpus comprising 1000 tweets and 1000 PubMed sentences selected using the same strategy and annotated at entity level by the same experts (pharmacists) using the same set of guidelines. Results The resulting corpus, annotated by two pharmacists, comprises semantically correct annotations for a set of drugs, diseases, and symptoms. This corpus contains the annotations for 3144 entities, 2749 relations, and 5003 attributes. Conclusions We present a corpus that is unique in its characteristics as this is the first corpus for pharmacovigilance curated from Twitter messages and PubMed sentences using the same data selection and annotation strategies. We believe this corpus will be of particular interest for researchers willing to compare results from pharmacovigilance systems (eg, classifiers and named entity recognition systems) when using data from Twitter and from PubMed. We hope that given the comprehensive set of drug names and the annotated entities and relations, this corpus becomes a standard resource to compare results from different pharmacovigilance studies in the area of NLP. PMID:28468748
Jeuken, Ralph M; Schotanus, Martijn G M; Kort, Nanne P; Deenik, Axel; Jong, Bob; Hendrickx, Roel P M
2016-07-01
Hallux valgus is one of the most common foot deformities. This long-term follow-up study compared the results of 2 widely used operative treatments for hallux valgus: the scarf and chevron osteotomy. Conventional weight bearing anteroposterior (AP) radiographs of the foot were made for evaluating the intermetatarsal angle and hallux valgus angle. For clinical evaluation, the American Orthopaedic Foot & Ankle Society (AOFAS) rating system for the hallux metatarsophalangeal-interphalangeal scale was used together with physical examination of the foot. These data were compared with the results from the original study. The Short Form 36 questionnaire, the Manchester-Oxford Foot Questionnaire (MOXFQ), and a general questionnaire including a visual analog scale (VAS) pain score were used for subjective evaluation. The primary outcome measures were the radiologic recurrence of hallux valgus and reoperation rate of the same toe. Secondary outcome measures were the results from the radiographs and subjective and clinical evaluation. The response rate was 76% at the follow-up of 14 years; in the chevron group, 37 feet were included compared with 36 feet in the scarf group. Twenty-eight feet in the chevron group and 27 in the scarf group developed recurrence of hallux valgus (P = .483). One patient in the scarf group had a reoperation of the same toe compared with none in the chevron group (P = .314). Current VAS pain scores and results from the SF-36, MOXFQ, and AOFAS did not significantly differ between groups. Both techniques showed similar results after 2 years of follow-up. At 14 years of follow-up, neither technique was superior in preventing recurrence. Level II, randomized controlled trial. © The Author(s) 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Bree, L.; Marra, M.; Rombout, P.J.
1992-10-01
Rats and guinea pigs were exposed to 0.8 mg ozone (O3)/m3 (approximately 0.4 ppm) for 12 hr during the daytime, 12 hr during the nighttime, or continuously to investigate circadian variation in O3-induced pulmonary toxicity during single and repeated O3 exposures. Biomarkers in bronchoalveolar lavage (BAL) fluid and lung tissues were measured as indicators of biochemical and inflammatory responses. Nighttime O3 exposure of rats resulted in larger increases of protein, albumin, and inflammatory cells in BAL fluid compared to those after daytime O3 exposure and this daytime-nighttime difference was statistically significant (p < 0.05). Single daytime or nighttime O3 exposuremore » of guinea pigs resulted in comparable increases of BAL fluid proteins and inflammatory cells without a daytime-nighttime difference. Nighttime and continuous O3 exposure of rats for 3 days resulted in comparable increases in lung antioxidant enzyme activities, both of which differed statistically from effects from daytime O3 exposures (p < 0.05). Continuous O3 exposure of guinea pigs for 3 days caused, in general, statistically larger increases in lung tissue parameters compared to nighttime O3 exposures (p < 0.05). These results suggest that the extent of O3-induced acute pulmonary biochemical and inflammatory responses is directly related to the level of physical and respiratory activity. For rats, effects from continuous O3 exposure appear to be controlled by the nighttime, physically active period. In guinea pigs, the comparable responses following daytime or nighttime O3 exposure seem in accordance with their random behavioral daily activity pattern. This study supports the view that physical activity-related increases in inhaled dose significantly enhance the pulmonary O3 responses.« less
Lehmann, Y; Ayerle, G; Beutner, K; Karge, K; Behrens, J; Landenberger, M
2016-06-01
This is about some results of a study called "Appraisal of the educational programmes and qualifications of health professions: a European Comparison" (in short: GesinE). It was carried out in the years 2009-2013, commissioned by the BMBF and supported by the BIBB. It is focussed on Germany, France, Great Britain, the Netherlands and Austria. The objectives have been (i) an inventory and comparative international synoptic presentation of education programmes of 16 health professions, (ii) a comparative international qualification analysis for the professions of radiographer, physiotherapist and nurse and (iii) the exposure of key aspects of the health-care and education systems in the compared countries. This is a comparative multi-sectional study for which a mixed methods approach with qualitative and quantitative elements was used. According to the results of this study it is necessary that current qualification paths and competence profiles of the health professions are developed continuously in Germany. In this process the German education and the secondary education sector should not be underrated. At the same time the results suggest that there are advantages in some aspects in the academic education (which is the norm for most of the analysed professions in the surveyed countries) compared to the existing education programmes in the secondary sector. This in particular applies to the competence for finding and transferring scientific knowledge into practice and for implementing reflected processes for decision making. The results improve the basis of the current debate in Germany about the development and reorganisation of the profiles of health professions and their qualification in a European context. © Georg Thieme Verlag KG Stuttgart · New York.
UNS S31603 Stainless Steel Tungsten Inert Gas Welds Made with Microparticle and Nanoparticle Oxides
Tseng, Kuang-Hung; Lin, Po-Yu
2014-01-01
The purpose of this study was to investigate the difference between tungsten inert gas (TIG) welding of austenitic stainless steel assisted by microparticle oxides and that assisted by nanoparticle oxides. SiO2 and Al2O3 were used to investigate the effects of the thermal stability and the particle size of the activated compounds on the surface appearance, geometric shape, angular distortion, delta ferrite content and Vickers hardness of the UNS S31603 stainless steel TIG weld. The results show that the use of SiO2 leads to a satisfactory surface appearance compared to that of the TIG weld made with Al2O3. The surface appearance of the TIG weld made with nanoparticle oxide has less flux slag compared with the one made with microparticle oxide of the same type. Compared with microparticle SiO2, the TIG welding with nanoparticle SiO2 has the potential benefits of high joint penetration and less angular distortion in the resulting weldment. The TIG welding with nanoparticle Al2O3 does not result in a significant increase in the penetration or reduction of distortion. The TIG welding with microparticle or nanoparticle SiO2 uses a heat source with higher power density, resulting in a higher ferrite content and hardness of the stainless steel weld metal. In contrast, microparticle or nanoparticle Al2O3 results in no significant difference in metallurgical properties compared to that of the C-TIG weld metal. Compared with oxide particle size, the thermal stability of the oxide plays a significant role in enhancing the joint penetration capability of the weld, for the UNS S31603 stainless steel TIG welds made with activated oxides. PMID:28788704
UNS S31603 Stainless Steel Tungsten Inert Gas Welds Made with Microparticle and Nanoparticle Oxides.
Tseng, Kuang-Hung; Lin, Po-Yu
2014-06-20
The purpose of this study was to investigate the difference between tungsten inert gas (TIG) welding of austenitic stainless steel assisted by microparticle oxides and that assisted by nanoparticle oxides. SiO₂ and Al₂O₃ were used to investigate the effects of the thermal stability and the particle size of the activated compounds on the surface appearance, geometric shape, angular distortion, delta ferrite content and Vickers hardness of the UNS S31603 stainless steel TIG weld. The results show that the use of SiO₂ leads to a satisfactory surface appearance compared to that of the TIG weld made with Al₂O₃. The surface appearance of the TIG weld made with nanoparticle oxide has less flux slag compared with the one made with microparticle oxide of the same type. Compared with microparticle SiO₂, the TIG welding with nanoparticle SiO₂ has the potential benefits of high joint penetration and less angular distortion in the resulting weldment. The TIG welding with nanoparticle Al₂O₃ does not result in a significant increase in the penetration or reduction of distortion. The TIG welding with microparticle or nanoparticle SiO₂ uses a heat source with higher power density, resulting in a higher ferrite content and hardness of the stainless steel weld metal. In contrast, microparticle or nanoparticle Al₂O₃ results in no significant difference in metallurgical properties compared to that of the C-TIG weld metal. Compared with oxide particle size, the thermal stability of the oxide plays a significant role in enhancing the joint penetration capability of the weld, for the UNS S31603 stainless steel TIG welds made with activated oxides.
VVER-440 and VVER-1000 reactor dosimetry benchmark - BUGLE-96 versus ALPAN VII.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duo, J. I.
2011-07-01
Document available in abstract form only, full text of document follows: Analytical results of the vodo-vodyanoi energetichesky reactor-(VVER-) 440 and VVER-1000 reactor dosimetry benchmarks developed from engineering mockups at the Nuclear Research Inst. Rez LR-0 reactor are discussed. These benchmarks provide accurate determination of radiation field parameters in the vicinity and over the thickness of the reactor pressure vessel. Measurements are compared to calculated results with two sets of tools: TORT discrete ordinates code and BUGLE-96 cross-section library versus the newly Westinghouse-developed RAPTOR-M3G and ALPAN VII.0. The parallel code RAPTOR-M3G enables detailed neutron distributions in energy and space in reducedmore » computational time. ALPAN VII.0 cross-section library is based on ENDF/B-VII.0 and is designed for reactor dosimetry applications. It uses a unique broad group structure to enhance resolution in thermal-neutron-energy range compared to other analogous libraries. The comparison of fast neutron (E > 0.5 MeV) results shows good agreement (within 10%) between BUGLE-96 and ALPAN VII.O libraries. Furthermore, the results compare well with analogous results of participants of the REDOS program (2005). Finally, the analytical results for fast neutrons agree within 15% with the measurements, for most locations in all three mockups. In general, however, the analytical results underestimate the attenuation through the reactor pressure vessel thickness compared to the measurements. (authors)« less
Validation of numerical models for flow simulation in labyrinth seals
NASA Astrophysics Data System (ADS)
Frączek, D.; Wróblewski, W.
2016-10-01
CFD results were compared with the results of experiments for the flow through the labyrinth seal. RANS turbulence models (k-epsilon, k-omega, SST and SST-SAS) were selected for the study. Steady and transient results were analyzed. ANSYS CFX was used for numerical computation. The analysis included flow through sealing section with the honeycomb land. Leakage flows and velocity profiles in the seal were compared. In addition to the comparison of computational models, the divergence of modeling and experimental results has been determined. Tips for modeling these problems were formulated.
Comparative study of performance of neutral axis tracking based damage detection
NASA Astrophysics Data System (ADS)
Soman, R.; Malinowski, P.; Ostachowicz, W.
2015-07-01
This paper presents a comparative study of a novel SHM technique for damage isolation. The performance of the Neutral Axis (NA) tracking based damage detection strategy is compared to other popularly used vibration based damage detection methods viz. ECOMAC, Mode Shape Curvature Method and Strain Flexibility Index Method. The sensitivity of the novel method is compared under changing ambient temperature conditions and in the presence of measurement noise. Finite Element Analysis (FEA) of the DTU 10 MW Wind Turbine was conducted to compare the local damage identification capability of each method and the results are presented. Under the conditions examined, the proposed method was found to be robust to ambient condition changes and measurement noise. The damage identification in some is either at par with the methods mentioned in the literature or better under the investigated damage scenarios.
Hip joint center localisation: A biomechanical application to hip arthroplasty population
Bouffard, Vicky; Begon, Mickael; Champagne, Annick; Farhadnia, Payam; Vendittoli, Pascal-André; Lavigne, Martin; Prince, François
2012-01-01
AIM: To determine hip joint center (HJC) location on hip arthroplasty population comparing predictive and functional approaches with radiographic measurements. METHODS: The distance between the HJC and the mid-pelvis was calculated and compared between the three approaches. The localisation error between the predictive and functional approach was compared using the radiographic measurements as the reference. The operated leg was compared to the non-operated leg. RESULTS: A significant difference was found for the distance between the HJC and the mid-pelvis when comparing the predictive and functional method. The functional method leads to fewer errors. A statistical difference was found for the localization error between the predictive and functional method. The functional method is twice more precise. CONCLUSION: Although being more individualized, the functional method improves HJC localization and should be used in three-dimensional gait analysis. PMID:22919569
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Masood; Malik, Rabia, E-mail: rabiamalik.qau@gmail.com; Munir, Asif
In this article, the mixed convective heat transfer to Sisko fluid over a radially stretching surface in the presence of convective boundary conditions is investigated. The viscous dissipation and thermal radiation effects are also taken into account. The suitable transformations are applied to convert the governing partial differential equations into a set of nonlinear coupled ordinary differential equations. The analytical solution of the governing problem is obtained by using the homotopy analysis method (HAM). Additionally, these analytical results are compared with the numerical results obtained by the shooting technique. The obtained results for the velocity and temperature are analyzed graphicallymore » for several physical parameters for the assisting and opposing flows. It is found that the effect of buoyancy parameter is more prominent in case of the assisting flow as compared to the opposing flow. Further, in tabular form the numerical values are given for the local skin friction coefficient and local Nusselt number. A remarkable agreement is noticed by comparing the present results with the results reported in the literature as a special case.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, T.F.; Thorne, P.G.; Myers, K.F.
Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less
ERIC Educational Resources Information Center
Miranda, Regina; Scott, Michelle; Hicks, Roger; Wilcox, Holly C.; Munfakh, Jimmie Lou Harris; Shaffer, David
2008-01-01
The study compares psychiatric diagnoses and future suicide attempt outcomes of multiple attempters (MAs), single attempters (SAs) and ideators. The results conclude that MAs strongly predict later suicide attempts and diagnosis than SAs and ideators.
Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Dugdale, Evan M; Hansen, Derek; Cote, Mark P; Bradley, James P; Romeo, Anthony A; Arciero, Robert A; Beitzel, Knut
2012-08-01
Clinical application of platelet-rich plasma (PRP) in the realm of orthopaedic sports medicine has yielded variable results. Differences in separation methods and variability of the individual may contribute to these variable results. To compare the effects of different PRP separation methods on human bone, muscle, and tendon cells in an in vitro model. Controlled laboratory study. Blood collected from 8 participants (mean ± SD age 31.6 ± 10.9 years) was used to obtain PRP preparations. Three different PRP separation methods were used: a single-spin process yielding a lower platelet concentration (PRP(LP)), a single-spin process yielding high platelet and white blood cell concentrations (PRP(HP)), and a double-spin that produces a higher platelet concentration and lower white blood cell concentration (PRP(DS)). Human bone, muscle, and tendon cells obtained from discarded tissue samples during shoulder surgery were placed into culture and treated with the 3 PRP preparations, control media (2% fetal bovine serum [FBS] and 10% FBS), and native blood. Radioactive thymidine assays were obtained to examine cell proliferation, and testing with enzyme-linked immunosorbent assay was used to determine growth factor concentrations. Addition of PRP(LP) to osteocytes, myocytes, and tenocytes significantly increased cell proliferation (P ≤ .05) compared with the controls. Adding PRP(DS) to osteoblasts and tenocytes increased cell proliferation significantly (P ≤ .05), but no significance was shown for its addition to myocytes. The addition of PRP(HP) significantly increased cell proliferation compared with the controls only when added to tenocytes (P ≤ .05). Osteoblasts: Proliferation was significantly increased by addition of PRP(LP) compared with all controls (2% FBS, 10% FBS, native blood) (P ≤ .05). Addition of PRP(DS) led to significantly increased proliferation compared with all controls, native blood, and PRP(HP) (P ≤ .05). Proliferation was significantly less when PRP(HP) was added compared with PRP(DS) (P ≤ .05). Myocytes: Proliferation was significantly increased by addition of PRP(LP) compared with native blood (P ≤ .05). Adding PRP(HP) or PRP(DS) to myocytes showed no significant increase in proliferation compared with the controls or the other separations. Tenocytes: Proliferation was significantly increased by addition of PRP(LP) compared with all controls (2% FBS, 10% FBS, native blood) (P ≤ .05). Addition of PRP(DS) showed a significant increase compared with the controls and native blood. For tenocytes, there was a significant increase (P ≤ .05) seen when PRP(HP) was added compared with the controls and native blood but not compared with the other separations. The primary findings of this study suggest the application of different PRP separations may result in a potential beneficial effect on the clinically relevant target cells in vitro. However, it is unclear which platelet concentration or PRP preparation may be optimal for the treatment of various cell types. In addition, a "more is better" theory for the use of higher platelet concentrations cannot be supported. This study was not intended to prove efficacy but to provide a platform for future research to be built upon. The utilization of different PRP separations may result in a potentially beneficial effect on the clinically relevant target cells in vitro, but it is unclear which platelet concentration or PRP preparation may be optimal for the treatment of various cell types.
Clinical pathology results from cranes with experimental West Nile Virus infection
Olsen, Glenn H.
2011-01-01
Sandhill cranes (Grus canadensis) were vaccinated for and then challenged with West Nile virus. Resulting titers demonstrated protection in the vaccinated-challenged cranes as compared to the unvaccinated-challenged cranes. Clinical pathology results showed challenged cranes, whether vaccinated or not, had a decrease in their hematocrits and an elevation of 2.5-fold in their white blood cell counts as compared to unchallenged control sandhill cranes. No differences were apparent in the differential counts of heterophils and lymphocytes.
Quality factor analysis for aberrated laser beam
NASA Astrophysics Data System (ADS)
Ghafary, B.; Alavynejad, M.; Kashani, F. D.
2006-12-01
The quality factor of laser beams has attracted considerable attention and some different approaches have been reported to treat the problem. In this paper we analyze quality factor of laser beam and compare the effect of different aberrations on beam quality by expanding pure phase term of wavefront in terms of Zernike polynomials. Also we analyze experimentally the change of beam quality for different Astigmatism aberrations, and compare theoretical results with experimentally results. The experimental and theoretical results are in good agreement.
Proof test of the computer program BUCKY for plasticity problems
NASA Technical Reports Server (NTRS)
Smith, James P.
1994-01-01
A theoretical equation describing the elastic-plastic deformation of a cantilever beam subject to a constant pressure is developed. The theoretical result is compared numerically to the computer program BUCKY for the case of an elastic-perfectly plastic specimen. It is shown that the theoretical and numerical results compare favorably in the plastic range. Comparisons are made to another research code to further validate the BUCKY results. This paper serves as a quality test for the computer program BUCKY developed at NASA Johnson Space Center.
Region-based multi-step optic disk and cup segmentation from color fundus image
NASA Astrophysics Data System (ADS)
Xiao, Di; Lock, Jane; Manresa, Javier Moreno; Vignarajan, Janardhan; Tay-Kearney, Mei-Ling; Kanagasingam, Yogesan
2013-02-01
Retinal optic cup-disk-ratio (CDR) is a one of important indicators of glaucomatous neuropathy. In this paper, we propose a novel multi-step 4-quadrant thresholding method for optic disk segmentation and a multi-step temporal-nasal segmenting method for optic cup segmentation based on blood vessel inpainted HSL lightness images and green images. The performance of the proposed methods was evaluated on a group of color fundus images and compared with the manual outlining results from two experts. Dice scores of detected disk and cup regions between the auto and manual results were computed and compared. Vertical CDRs were also compared among the three results. The preliminary experiment has demonstrated the robustness of the method for automatic optic disk and cup segmentation and its potential value for clinical application.
Cory, Theodore J; Winchester, Lee C; Robbins, Brian L; Fletcher, Courtney V
2015-01-01
Background: Determination of cell-associated antiretroviral drug concentrations is necessary for research into reservoirs of HIV. Variation exists in cell-associated drug concentrations among research groups. One cause for this may be washing cells during processing. We explored spinning cells through oil to minimize this variability. Methods & results: Raltegravir, atazanavir, darunavir, efavirenz, lopinavir and ritonavir concentrations were assessed in CEM.ss T cells washed with HBSS and oil-spun cells. Oil-spun cells had significantly higher concentrations for all drugs compared with samples washed with HBSS. Conclusion: The decline in cell-associated drug concentrations with saline washes compared with a single spin through oil shows the utility of a spin through oil. Oil centrifugation results in high cell-associated drug concentrations, and can be done in a fast, efficient manner. PMID:26168252
GoPros™ as an underwater photogrammetry tool for citizen science
David, Peter A.; Dupont, Sally F.; Mathewson, Ciaran P.; O’Neill, Samuel J.; Powell, Nicholas N.; Williamson, Jane E.
2016-01-01
Citizen science can increase the scope of research in the marine environment; however, it suffers from necessitating specialized training and simplified methodologies that reduce research output. This paper presents a simplified, novel survey methodology for citizen scientists, which combines GoPro imagery and structure from motion to construct an ortho-corrected 3D model of habitats for analysis. Results using a coral reef habitat were compared to surveys conducted with traditional snorkelling methods for benthic cover, holothurian counts, and coral health. Results were comparable between the two methods, and structure from motion allows the results to be analysed off-site for any chosen visual analysis. The GoPro method outlined in this study is thus an effective tool for citizen science in the marine environment, especially for comparing changes in coral cover or volume over time. PMID:27168973
GoPros™ as an underwater photogrammetry tool for citizen science.
Raoult, Vincent; David, Peter A; Dupont, Sally F; Mathewson, Ciaran P; O'Neill, Samuel J; Powell, Nicholas N; Williamson, Jane E
2016-01-01
Citizen science can increase the scope of research in the marine environment; however, it suffers from necessitating specialized training and simplified methodologies that reduce research output. This paper presents a simplified, novel survey methodology for citizen scientists, which combines GoPro imagery and structure from motion to construct an ortho-corrected 3D model of habitats for analysis. Results using a coral reef habitat were compared to surveys conducted with traditional snorkelling methods for benthic cover, holothurian counts, and coral health. Results were comparable between the two methods, and structure from motion allows the results to be analysed off-site for any chosen visual analysis. The GoPro method outlined in this study is thus an effective tool for citizen science in the marine environment, especially for comparing changes in coral cover or volume over time.
NASA Astrophysics Data System (ADS)
Ravi Babu, S.; Sambasiva Rao, G.
2018-04-01
The main objective of this study is to investigate the stability and dielectric breakdown strength of alumina-transformer oil nanofluids as stability issue is the major concern when it is used for practical applications. UV-Vis spectrophotometer and Oil tester were used to measure absorbance and breakdown voltage of nanofluids respectively. As per the experimental results, correlations were developed using regression analysis. Experimental results were compared with the predicted values of BDVE and absorbance and presented. The maximum errors obtained by comparing the experimental and predicted results for BDVE and absorbance are -2.913% and 4.89% respectively. It is also observed that there is a decrement in both BDVE and absorbance for nanofluids of aged 1 day compared to fresh ones. This decrement is due to the sedimentation of nanoparticles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauer, Mark A.; Poirier, David R.; Erdmann, Robert G.
2014-09-01
This report covers the modeling of seven directionally solidified samples, five under normal gravitational conditions and two in microgravity. A model is presented to predict macrosegregation during the melting phases of samples solidified under microgravitational conditions. The results of this model are compared against two samples processed in microgravity and good agreement is found. A second model is presented that captures thermosolutal convection during directional solidification. Results for this model are compared across several experiments and quantitative comparisons are made between the model and the experimentally obtained radial macrosegregation profiles with good agreement being found. Changes in cross section weremore » present in some samples and micrographs of these are qualitatively compared with the results of the simulations. It is found that macrosegregation patterns can be affected by changing the mold material.« less
NASA Technical Reports Server (NTRS)
Lee, S. S.; Sengupta, S.; Nwadike, E. V.; Sinha, S. K.
1980-01-01
The rigid lid model was developed to predict three dimensional temperature and velocity distributions in lakes. This model was verified at various sites (Lake Belews, Biscayne Bay, etc.) and th verification at Lake Keowee was the last of these series of verification runs. The verification at Lake Keowee included the following: (1) selecting the domain of interest, grid systems, and comparing the preliminary results with archival data; (2) obtaining actual ground truth and infrared scanner data both for summer and winter; and (3) using the model to predict the measured data for the above periods and comparing the predicted results with the actual data. The model results compared well with measured data. Thus, the model can be used as an effective predictive tool for future sites.
Schaefer, Alexander; Brach, Jennifer S.; Perera, Subashan; Sejdić, Ervin
2013-01-01
Background The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f) = 1/fβ. The scaling exponent β is thus often interpreted as a “biomarker” of relative health and decline. New Method This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. Results The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Comparison with Existing Methods: Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. Conclusions The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. PMID:24200509
A Study of Comparative Advantage and Intra-Industry Trade in the Pharmaceutical Industry of Iran
Yusefzadeh, Hassan; Rezapour, Aziz; Lotfi, Farhad; Azar, Farbod Ebadifard; Nabilo, Bahram; Gorji, Hassan Abolghasem; Hadian, Mohammad; Shahidisadeghi, Niusha; Karami, Atiyeh
2015-01-01
Background: Drug costs in Iran accounts for about 30% of the total health care expenditure. Moreover, pharmaceutical business lies among the world’s greatest businesses. The aim of this study was to analyze Iran’s comparative advantage and intra-industry trade in pharmaceuticals so that suitable policies can be developed and implemented in order to boost Iran’s trade in this field. Methods: To identify Iran’s comparative advantage in pharmaceuticals, trade specialization, export propensity, import penetration and Balassa and Vollrath indexes were calculated and the results were compared with other pharmaceutical exporting countries. The extent and growth of Iran’s intra-industry trade in pharmaceuticals were measured and evaluated using the Grubel-Lloyd and Menon-Dixon indexes. The required data was obtained from Iran’s Customs Administration, Iran’s pharmaceutical Statistics, World Bank and International Trade Center. Results: The results showed that among pharmaceutical exporting countries, Iran has a high level of comparative disadvantage in pharmaceutical products because it holds a small share in world’s total pharmaceutical exports. Also, the low extent of bilateral intra-industry trade between Iran and its trading partners in pharmaceuticals shows the trading model of Iran’s pharmaceutical industry is mostly inter-industry trade rather than intra-industry trade. In addition, the growth of Iran’s intra-industry trade in pharmaceuticals is due to its shares of imports from pharmaceutical exporting countries to Iran and exports from Iran to its neighboring countries. Conclusions: The results of the analysis can play a valuable role in helping pharmaceutical companies and policy makers to boost pharmaceutical trade. PMID:26153184
Patel, Sandeep; Kubavat, Ajay; Ruparelia, Brijesh; Agarwal, Arvind; Panda, Anup
2012-01-01
The aim of periodontal surgery is complete regeneration. The present study was designed to evaluate and compare clinically soft tissue changes in form of probing pocket depth, gingival shrinkage, attachment level and hard tissue changes in form of horizontal and vertical bone level using resorbable membranes. Twelve subjects with bilateral class 2 furcation defects were selected. After initial phase one treatment, open debridement was performed in control site while freezedried dura mater allograft was used in experimental site. Soft and hard tissue parameters were registered intrasurgically. Nine months reentry ensured better understanding and evaluation of the final outcome of the study. Guided tissue regeneration is a predictable treatment modality for class 2 furcation defect. There was statistically significant reduction in pocket depth as compared to control (p < 0.01). There is statistically significant increase in periodontal attachment level within control and experimental sites showed better results (p < 0.01). For hard tissue parameter, significant defect fill resulted in experimental group, while in control group, less significant defect fill was found in horizontal direction and nonsignificant defect fill was found in vertical direction. The results showed statistically significant improvement in soft and hard tissue parameters and less gingival shrinkage in experimental sites compared to control site. The use of FDDMA in furcation defects helps us to achieve predictable results. This cross-linked collagen membrane has better handling properties and ease of procurement as well as economic viability making it a logical material to be used in regenerative surgeries.
Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial
Halldorsdottir, Solveig; Warchal-Windham, Mary Ellen; Wallace, Jane F.; Pardo, Scott; Parkes, Joan Lee; Simmons, David A.
2013-01-01
Background This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. Methods Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject was tested with fresh (natural) blood; the other samples were glycolyzed to lower blood glucose to <70 mg/dl. Meter results were compared with results from plasma from the same sample tested on a Yellow Springs Instruments (YSI) 2300 STAT Plus™ glucose analyzer. Blood glucose monitoring system accuracy was compared using mean absolute relative difference (MARD; from laboratory reference method results) and other analyses. Separate analyses on fresh (natural) samples only were conducted to determine potential effects of glycolysis on MARD values of systems utilizing glucose-oxidase-based test strip chemistry. Results Across the tested glucose range, the EZ had the lowest MARD of 4.7%; the ACAP, FFL, OTU2, and TT had MARD values of 6.3%, 18.3%, 23.4%, and 26.2%, respectively. For samples with glucose concentrations <70 mg/dl, the EZ had the lowest MARD (0.65%), compared with the ACAP (2.5%), FFL (18.3%), OTU2 (22.4%), and TT (33.2%) systems. Conclusions The EZ had the lowest MARD across the tested glucose ranges when compared with four other BGMSs when all samples were analyzed as well as when natural samples only were analyzed. PMID:24124957
Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G
2014-01-01
Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.
Emery, Paul; Vencovský, Jiří; Sylwestrzak, Anna; Leszczyński, Piotr; Porawska, Wieslawa; Baranauskaite, Asta; Tseluyko, Vira; Zhdan, Vyacheslav M.; Stasiuk, Barbara; Milasiene, Roma; Barrera Rodriguez, Aaron Alejandro; Cheong, Soo Yeon; Ghil, Jeehoon
2017-01-01
Abstract Objective To compare the 52-week efficacy and safety of SB4 [an etanercept biosimilar] with reference etanercept (ETN) in patients with active RA. Methods In a phase 3, randomized, double-blind, multicentre study, patients with moderate to severe RA despite MTX treatment were randomized to receive 50 mg/week of s.c. SB4 or ETN up to week 52. Efficacy assessments included ACR response rates, 28-joint DAS, Simplified and Clinical Disease Activity Indices and changes in the modified total Sharp score (mTSS). Safety and immunogenicity were also evaluated. Results A total of 596 patients were randomized to receive either SB4 (n = 299) or ETN (n = 297) and 505 (84.7%) patients completed 52 weeks of the study. At week 52, the ACR20 response rates in the per-protocol set were comparable between SB4 (80.8%) and ETN (81.5%). All efficacy results were comparable between the two groups and they were maintained up to week 52. Radiographic progression was also comparable and the change from baseline in the mTSS was 0.45 for SB4 and 0.74 for ETN. The safety profile of SB4 was similar to that of ETN and the incidence of anti-drug antibody development up to week 52 was 1.0 and 13.2% in the SB4 and ETN groups, respectively. Conclusion Efficacy including radiographic progression was comparable between SB4 and ETN up to week 52. SB4 was well tolerated and had a similar safety profile to that of ETN. Trial registration number ClinicalTrials.gov NCT01895309, EudraCT 2012-005026-30 PMID:28968793
Kane, John M; Kishimoto, Taishiro; Correll, Christoph U
2013-08-01
As psychopathology and social functioning can worsen with repeated psychotic episodes in schizophrenia, relapse prevention is critical. Because high nonadherence rates limit the efficacy of pharmacotherapy, the use of long-acting injectable (LAI) antipsychotics is considered an important treatment option. To date, many studies comparing LAIs and oral antipsychotics have been conducted; however, the results are mixed, and careful interpretation of the data is required. Selective review of existing literature regarding LAIs. We especially focused the discussion on the impact of the design of studies with different approaches comparing LAIs and oral antipsychotics in preventing relapse. The results were diverse and were influenced by the design used, that is, randomized controlled trials (RCTs) showed LAIs and oral antipsychotics to have similar effects, whereas mirror-image and some large cohort studies showed LAIs to be superior to oral antipsychotics. Divergent results from studies using different methodologies create a dilemma for comparative effectiveness research, and LAI studies may serve as an example of a situation in which a conventional RCT is not the gold standard. Traditional RCTs generally increase adherence compared with clinical practice and, therefore, might not be well suited to detect differences between LAIs and oral medications, because any increase in adherence affects patients on oral medications more than those on LAIs and thus leads to an underestimation of any potential difference in effectiveness. A possible solution would be the implementation of a true effectiveness trial in which post-randomization involvement would be kept to a minimum to better reflect routine practice. Copyright © 2013 Elsevier Inc. All rights reserved.
Mahaffey, Kenneth W.; Stevens, Susanna R.; White, Harvey D.; Nessel, Christopher C.; Goodman, Shaun G.; Piccini, Jonathan P.; Patel, Manesh R.; Becker, Richard C.; Halperin, Jonathan L.; Hacke, Werner; Singer, Daniel E.; Hankey, Graeme J.; Califf, Robert M.; Fox, Keith A.A.; Breithardt, Günter
2014-01-01
Aims We investigated the prevalence of prior myocardial infarction (MI) and incidence of ischaemic cardiovascular (CV) events among atrial fibrillation (AF) patients. Methods and results In ROCKET AF, 14 264 patients with nonvalvular AF were randomized to rivaroxaban or warfarin. The key efficacy outcome for these analyses was CV death, MI, and unstable angina (UA). This pre-specified analysis was performed on patients while on treatment. Rates are per 100 patient-years. Overall, 2468 (17%) patients had prior MI at enrollment. Compared with patients without prior MI, these patients were more likely to be male (75 vs. 57%), on aspirin at baseline (47 vs. 34%), have prior congestive heart failure (78 vs. 59%), diabetes (47 vs. 39%), hypertension (94 vs. 90%), higher mean CHADS2 score (3.64 vs. 3.43), and fewer prior strokes or transient ischaemic attacks (46 vs. 54%). CV death, MI, or UA rates tended to be lower in patients assigned rivaroxaban compared with warfarin [2.70 vs. 3.15; hazard ratio (HR) 0.86, 95% confidence interval (CI) 0.73–1.00; P = 0.0509]. CV death, MI, or UA rates were higher in those with prior MI compared with no prior MI (6.68 vs. 2.19; HR 3.04, 95% CI 2.59–3.56) with consistent results for CV death, MI, or UA for rivaroxaban compared with warfarin in prior MI compared with no prior MI (P interaction = 0.10). Conclusion Prior MI was common and associated with substantial risk for subsequent cardiac events. Patients with prior MI assigned rivaroxaban compared with warfarin had a non-significant 14% reduction of ischaemic cardiac events. PMID:24132190
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhan, G., E-mail: gkuhan@nhs.net; Antoniou, G. A.; Nikam, M.
Purpose. To carry out a systematic review of randomized trials comparing surgery vs. endovascular therapy for occluded fistulas and grafts. Methods. All randomized trials which compared surgery and endovascular therapy for occluded fistulas and grafts were retrieved from 1990 onwards. The following search terms were used: 'haemodialysis,' 'thrombosis,' 'arteriovenous fistula,' 'arteriovenous shunt,' 'end stage renal failure' on Medline and PubMed. The results of the pooled data were analysed by a fixed-effect model. Results. There were no randomized trials comparing surgery vs. endovascular therapy for native fistulas and vein grafts. Six randomized studies reporting on 573 occluded grafts were identified. Technicalmore » success, need for access line and primary patency at 30 days were similar between the two groups (odds ratio [OR] 1.40, 95 % confidence interval [CI] 0.91-2.14; OR 0.77, 95 % CI 0.44-1.34; and OR 1.15, 95 % CI 0.79-1.68, respectively). There was no significant difference in morbidity at 30 days between groups (OR 1.12, 95 % CI 0.67-1.86). There were no statistical difference between the two groups for 1 year primary patency (OR 2.08, 95 % CI 0.97-4.45). Primary assisted patency at 1 year was better with surgery (OR 3.03, 95 % CI 1.12-8.18) in a single study. Conclusion. Comparable results to surgery have been achieved with endovascular techniques for occluded prosthetic grafts for dialysis access. Long-term data comparing the two groups were lacking. Further trials designed to encompass variation in methods are warranted in order to obtain the best available evidence particularly for native fistulas.« less
Novak-Weekley, S M; Marlowe, E M; Poulter, M; Dwyer, D; Speers, D; Rawlinson, W; Baleriola, C; Robinson, C C
2012-05-01
The Xpert Flu Assay cartridge is a next-generation nucleic acid amplification system that provides multiplexed PCR detection of the influenza A, influenza A 2009 H1N1, and influenza B viruses in approximately 70 min with minimal hands-on time. Six laboratories participated in a clinical trial comparing the results of the new Cepheid Xpert Flu Assay to those of culture or real-time PCR with archived and prospectively collected nasal aspirate-wash (NA-W) specimens and nasopharyngeal (NP) swabs from children and adults. Discrepant results were resolved by DNA sequence analysis. After discrepant-result analysis, the sensitivities of the Xpert Flu Assay for prospective NA-W specimens containing the influenza A, influenza A 2009 H1N1, and influenza B viruses compared to those of culture were 90.0%, 100%, and 100%, respectively, while the sensitivities of the assay for prospective NP swabs compared to those of culture were 100%, 100%, and 100%, respectively. The sensitivities of the Xpert Flu Assay for archived NA-W specimens compared to those of Gen-Probe ProFlu+ PCR for the influenza A, influenza A 2009 H1N1, and influenza B viruses were 99.4%, 98.4%, and 100%, respectively, while the sensitivities of the Xpert Flu Assay for archived NP swabs compared to those of ProFlu+ were 98.1%, 100%, and 93.8%, respectively. The sensitivities of the Xpert Flu Assay with archived NP specimens compared to those of culture for the three targets were 97.5%, 100%, and 93.8%, respectively. We conclude that the Cepheid Xpert Flu Assay is an accurate and rapid method that is suitable for on-demand testing for influenza viral infection.
2010-01-01
Background Prevalence of asthma and allergies in top athletes is high. However, most previous studies did not include a general population comparison group. We aimed to compare the prevalence of asthma, allergies and medical treatment in different groups of German top athletes to the general population. Methods Prior to the 2008 Summer Olympic Games, 291 German candidates for participation (65%) completed a questionnaire on respiratory and allergic symptoms. Results were compared to those of a general population study in Germany (n = 2425, response 68%). Furthermore, associations between types of sports and the self-reported outcomes were calculated. All models were adjusted for age, sex, level of education and smoking. Results Athletes reported significantly more doctors' diagnosed asthma (17% vs. 7%), more current use of asthma medication (10% vs. 4%) and allergic rhinitis (25% vs. 17%) compared to the general population. After adjustment, top athletes only had an increased Odds Ratio for doctor's diagnosed asthma (OR: 1.6; 95% CI 1.1-2.5). Compared to the general population, athletes in endurance sports had an increased OR for doctor's diagnosed asthma (2.4; 1.5-3.8) and current use of asthma medication (1.8; 1.0-3.4). In this group, current wheeze was increased when use of asthma medication was taken into account (1.8; 1.1-2.8). For other groups of athletes, no significantly increased ORs were observed. Conclusions Compared to the general population, an increased risk of asthma diagnosis and treatment was shown for athletes involved in endurance sports. This might be due to a better medical surveillance and treatment of these athletes. PMID:21118543
Muraki, Masato; Gose, Kyuya; Hanada, Soichiro; Sawaguchi, Hirochiyo; Tohda, Yuji
2017-11-01
Two main types of devices are used to facilitate the administration of inhaled corticosteroid (ICS) and long-acting β-agonist (LABA) in combination, dry powder inhalers (DPIs) and pressurized metered-dose inhalers (pMDIs). There are few reports comparing the effects of the two devices, and it is unknown which should be recommended for asthma patients with given sets of characteristics. In the current study, the beneficial effects and side effects associated with DPIs and pMDIs were compared, and the question of which device should be recommended for asthma patients was investigated. A prospective, randomized, crossover, comparative study in adult outpatients with asthma was conducted using salmeterol/fluticasone propionate combination (SFC) 50 μg/250 μg, one inhalation of Adoair ® 250 Diskus ® twice daily or two inhalations of Adoair ® 125 Aerosol twice daily, for 8 weeks. Questionnaires, exhaled nitric oxide (FeNO) tests and pulmonary function tests were administered after the use of each device for 8 weeks, and the results derived from each device were compared. Sixty-eight subjects were included in the final analysis. There were no significant differences between quality-of-life scores, FeNO, spirometry test results and forced oscillation results. With regard to patient preferences, 57.4% preferred the Adoair ® Aerosol and 35.3% preferred the Adoair ® Diskus ® , as determined via the comparative evaluation questionnaire. Although DPI prescription accounts for the predominant market share of combined ICS/LABA in Japan, patients preferred a pMDI device to a DPI device. Compared to DPIs, pMDIs may be the preferential choice for patients with asthma.
Kordasiewicz, Bartłomiej; Małachowski, Konrad; Kicinski, Maciej; Chaberek, Sławomir; Pomianowski, Stanisław
2017-05-01
The aim of this study was to compare early clinical results after open and arthroscopic Latarjet stabilisation in anterior shoulder instability. Our hypothesis was the results of arthroscopic stabilisation were comparable with the results of open procedure. The clinical results of the patients after primary Latarjet procedure were analysed. Patients operated on between 2006 and 2011 using an open technique composed the OPEN group and patients operated on arthroscopically between 2011 and 2013 composed the ARTHRO group; 48 out of 55 shoulders (87%) in OPEN and 62 out of 64 shoulders (97%) in ARTHRO were available to follow-up. The average age at surgery was 28 years in OPEN and 26 years in ARTHRO. The mean follow-up was 54.2 months in OPEN and 23.4 months in ARTHRO. Intra-operative data were analysed regarding time of surgery, concomitant lesions and complications. Patient results were assessed with Walch-Duplay, Rowe, VAS scores and subjective self-evaluation of satisfaction and shoulder function. Computed tomography scan evaluation was used to assess the graft healing. Average time of surgery was significantly shorter in ARTHRO than OPEN: respectively 110 and 120 minutes. The number of intra-operative complications was six (12.5%) in OPEN and five (8.1%) in ARTHRO. The results were comparable in both groups, with no significant difference between OPEN and ARTHRO group: satisfaction rate - 96.8% and 91.9%, shoulder function - 92.2% and 90%, Walch-Duplay score - 83.9 and 76.7 respecively. A significant difference was reported in Rowe score: 87.8 in OPEN and 78.9 in ARTHRO. Another significant difference was found in the presence of "subjective apprehension"-a term referring to the subjective perception of instability with no signs of instability at clinical examination - 28.7% in OPEN and 50% in ARTHRO. Range of motion in both groups were comparable, however patients in OPEN had significantly lower loss of external rotation in adduction to the side comparing to the contralateral shoulder: 7° versus 14° in ARTHRO. Recurrence was reported in three cases in each group: 6.2% in OPEN and 4.8% in ARTHRO. A revision surgery was performed in four patients (9.3%) in OPEN and six (9.7%) in ARTHRO. Radiographic evaluation showed a significantly lower rate (5%) of graft healing problems (fracture, non-union and osteolysis) after arthroscopic stabilisation, however a partial osteolysis of the proximal part of the bone block was significantly more frequent (53.5%). The arthroscopic Latarjet stabilisation showed satisfactory and comparable results to open procedure. We recommend further investigation and development of arthroscopic technique. III.
Biomechanics of Two External Fixator Devices Used in Rat Femoral Fractures.
Osagie-Clouard, Liza; Kaufmann, Joshua; Blunn, Gordon; Coathup, Melanie; Pendegrass, Catherine; Meeson, Richard; Briggs, Timothy; Moazen, Mehran
2018-05-04
The use of external fixators allows for the direct investigation of newly formed interfragmentary bone, and the radiographic evaluation of the fracture. We validated the results of a finite element model with the in vitro stiffness' of two widely used external fixator devices used for in vivo analysis of fracture healing in rat femoral fractures with differing construction (Ti alloy ExFix1 and PEEK ExFix2). Rat femoral fracture fixation was modelled using two external fixators. For both constructs an osteotomy of 2.75 mm was used, and offset maintained at 5 mm. Tufnol, served as standardized substitutes for rat femora. Constructs were loaded under axial compression and torsion. Overall axial and torsional stiffness were compared between the in vitro models and FE results. FE models were also used to compare the fracture movement and overall pattern of von Mises stress across the external fixators. In vitro axial stiffness of ExFix1 was 29.26 N/mm ± 3.83 compared to ExFix2 6.31 N/mm ± 0.67 (p* < 0.05). Torsional stiffness of ExFix1 was 47.5 Nmm/° ± 2.71 compared to ExFix2 at 19.1 Nmm/° ± 1.18 (p* < 0.05). FE results predicted similar comparative ratios between the ExFix1 and 2 as the in vitro studies. FE results predicted considerably larger interfragmentary motion in the ExFix2 comparing to ExFix1. We demonstrated significant differences in the stiffness' of the two external fixators as one would expect from such variable designs; yet, importantly we validated the utility of an FE model for the analysis and prediction of changes in fracture mechanics dependent on fixator choice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Mc Hugh, Sheena; Marsden, Paul; Brennan, Carmel; Murphy, Katie; Croarkin, Celine; Moran, Joe; Harkins, Velma; Perry, Ivan J
2011-12-28
The aim of the present study was to assess the performance of three primary care-led initiatives providing structured care to patients with Type 2 diabetes in Ireland, a country with minimal incentives to promote the quality of care. Data, from three primary care initiatives, were available for 3010 adult patients with Type 2 diabetes. Results were benchmarked against the national guidelines for the management of Type 2 diabetes in the community and results from the National Diabetes Audit (NDA) for England (2008/2009) and the Scottish Diabetes Survey (2009). The recording of clinical processes of care was similar to results in the UK however the recording of lifestyle factors was markedly lower. Recording of HbA1c, blood pressure and lipids exceeded 85%. Recording of retinopathy screening (71%) was also comparable to England (77%) and Scotland (90%). Only 63% of patients had smoking status recorded compared to 99% in Scotland while 70% had BMI recorded compared to 89% in England. A similar proportion of patients in this initiative and the UK achieved clinical targets. Thirty-five percent of patients achieved a target HbA1c of < 6.5% (< 48 mmol/mol) compared to 25% in England. Applying the NICE target for blood pressure (≤ 140/80 mmHg), 54% of patients reached this target comparable to 60% in England. Slightly less patients were categorised as obese (> 30 kg/m²) in Ireland (50%, n = 1060) compared to Scotland (54%). This study has demonstrated what can be achieved by proactive and interested health professionals in the absence of national infrastructure to support high quality diabetes care. The quality of primary care-led diabetes management in the three initiatives studied appears broadly consistent with results from the UK with the exception of recording lifestyle factors. The challenge facing health systems is to establish quality assurance a responsibility for all health care professionals rather than the subject of special interest for a few.
Dual-echo ASL based assessment of motor networks: a feasibility study
NASA Astrophysics Data System (ADS)
Storti, Silvia Francesca; Boscolo Galazzo, Ilaria; Pizzini, Francesca B.; Menegaz, Gloria
2018-04-01
Objective. Dual-echo arterial spin labeling (DE-ASL) technique has been recently proposed for the simultaneous acquisition of ASL and blood-oxygenation-level-dependent (BOLD)-functional magnetic resonance imaging (fMRI) data. The assessment of this technique in detecting functional connectivity at rest or during motor and motor imagery tasks is still unexplored both per-se and in comparison with conventional methods. The purpose is to quantify the sensitivity of the DE-ASL sequence with respect to the conventional fMRI sequence (cvBOLD) in detecting brain activations, and to assess and compare the relevance of node features in decoding the network structure. Approach. Thirteen volunteers were scanned acquiring a pseudo-continuous DE-ASL sequence from which the concomitant BOLD (ccBOLD) simultaneously to the ASL can be extracted. The approach consists of two steps: (i) model-based analyses for assessing brain activations at individual and group levels, followed by statistical analysis for comparing the activation elicited by the three sequences under two conditions (motor and motor imagery), respectively; (ii) brain connectivity graph-theoretical analysis for assessing and comparing the network models properties. Main results. Our results suggest that cvBOLD and ccBOLD have comparable sensitivity in detecting the regions involved in the active task, whereas ASL offers a higher degree of co-localization with smaller activation volumes. The connectivity results and the comparative analysis of node features across sequences revealed that there are no strong changes between rest and tasks and that the differences between the sequences are limited to few connections. Significance. Considering the comparable sensitivity of the ccBOLD and cvBOLD sequences in detecting activated brain regions, the results demonstrate that DE-ASL can be successfully applied in functional studies allowing to obtain both ASL and BOLD information within a single sequence. Further, DE-ASL is a powerful technique for research and clinical applications allowing to perform quantitative comparisons as well as to characterize functional connectivity.
System and method of designing models in a feedback loop
Gosink, Luke C.; Pulsipher, Trenton C.; Sego, Landon H.
2017-02-14
A method and system for designing models is disclosed. The method includes selecting a plurality of models for modeling a common event of interest. The method further includes aggregating the results of the models and analyzing each model compared to the aggregate result to obtain comparative information. The method also includes providing the information back to the plurality of models to design more accurate models through a feedback loop.
NASA Astrophysics Data System (ADS)
Engelbrecht, J. A. A.
2018-04-01
Theoretical models used for the determination of the refractive index of InXGa1-XAs are reviewed and compared. Attention is drawn to some problems experienced with some of the models. Models also extended to the mid-infrared region of the electromagnetic spectrum. Theoretical results in the mid-infrared region are then compared to previously published experimental results.
ERIC Educational Resources Information Center
Aydin, Ayhan; Erdagf, Coskun; Tas, Nuray
2011-01-01
In this study it is aimed to describe and evaluate comparatively the reading literacy exam results, the finance of education and schools, and socio-cultural status of parents in Turkey and the top-five OECD countries, Finland, Korea, Canada, Australia, New Zealand respectively, in the light reports and publications by OECD regarding PISA 2003 and…
Advanced Technology for Ultra-Low Power System-on-Chip (SoC)
2017-06-01
design at IDS=1mA/μm compared with that in experimental 14nm-node FinFET. The redistributed electric field along the channel length direction can... design can result in more uniform electron density and electron velocity distributions compared to a homojunction device. This uniform electron... design at IDS=1mA/μm compared with that in experimental 14nm-node FinFET. 14 Approved for public release, distribution is unlimited. 0 5 10 15 20
2017-07-01
panels of MIBI multiplexed in situ detection reagents, and compare the quantitative data to the conventional clinically derived “one at a time” and...Measure standard curves for each analyte against western blots using cell lines and tumor samples. Compare quantitation dynamic ranges to...GSTM1, CD68, BAG1, ER, PGR, BCL2, SCUBE2, ACTB, GAPDH, RPLPO, GUS, TFRC) IIa. Compare hybridization results for mass tagged probe designs from both
Comparative study of oxihydrogen injection in turbocharged compression ignition engines
NASA Astrophysics Data System (ADS)
Barna, L.; Lelea, D.
2018-01-01
This document proposes for analysis, comparative study of the turbocharged, compression-ignition engine, equipped with EGR valve, operation in case the injection in intake manifold thereof a maximum flow rate of 1l/min oxyhydrogen resulted of water electrolysis, at two different injection pressures, namely 100 Pa and 3000 Pa, from the point of view of flue gas opacity. We found a substantial reduction of flue gas opacity in both cases compared to conventional diesel operation, but in different proportions.
Dosimetry and microdosimetry using COTS ICs: A comparative study
NASA Technical Reports Server (NTRS)
Scheick, L.; Swift, G.; Guertin, S.; Roth, D.; McNulty, P.; Nguyen, D.
2002-01-01
A new method using an array of MOS transistors formeasuring dose absorbed from ionizing radiation is compared to previous dosimetric methods., The accuracy and precision of dosimetry based on COTS SRAMs, DRAMs, and WPROMs are compared and contrasted. Applications of these devices in various space missions will be discussed. TID results are presented for this summary and microdosimetricresults will be added to the full paper. Finally, an analysis of the optimal condition for a digital dosimeter will be presented.
Anonymity communication VPN and Tor: a comparative study
NASA Astrophysics Data System (ADS)
Ramadhani, E.
2018-03-01
VPN and Tor is a technology based on anonymity communication. These two technologies have their advantage and disadvantage. The objective of this paper is to find the difference between VPN and Tor technologies by comparing their security of communication on the public network based on the CIA triad concept. The comparative study in this paper is based on the survey method. At last, the result of this paper is a recommendation on when to use a VPN and Tor to secure communication
Wu, G; Li, J
1999-01-01
Identifying and accessing reliable, relevant consumer health information rapidly on the Internet may challenge the health sciences librarian and layperson alike. In this study, seven search engines are compared using representative consumer health topics for their content relevancy, system features, and attributes. The paper discusses evaluation criteria; systematically compares relevant results; analyzes performance in terms of the strengths and weaknesses of the search engines; and illustrates effective search engine selection, search formulation, and strategies. PMID:10550031
Quantified Uncertainties in Comparative Life Cycle Assessment: What Can Be Concluded?
2018-01-01
Interpretation of comparative Life Cycle Assessment (LCA) results can be challenging in the presence of uncertainty. To aid in interpreting such results under the goal of any comparative LCA, we aim to provide guidance to practitioners by gaining insights into uncertainty-statistics methods (USMs). We review five USMs—discernibility analysis, impact category relevance, overlap area of probability distributions, null hypothesis significance testing (NHST), and modified NHST–and provide a common notation, terminology, and calculation platform. We further cross-compare all USMs by applying them to a case study on electric cars. USMs belong to a confirmatory or an exploratory statistics’ branch, each serving different purposes to practitioners. Results highlight that common uncertainties and the magnitude of differences per impact are key in offering reliable insights. Common uncertainties are particularly important as disregarding them can lead to incorrect recommendations. On the basis of these considerations, we recommend the modified NHST as a confirmatory USM. We also recommend discernibility analysis as an exploratory USM along with recommendations for its improvement, as it disregards the magnitude of the differences. While further research is necessary to support our conclusions, the results and supporting material provided can help LCA practitioners in delivering a more robust basis for decision-making. PMID:29406730
NASA Astrophysics Data System (ADS)
Kubota, Y.; Nagatsuma, T.; Den, M.; Nakamizo, A.; Matsumoto, H.; Tanaka, T.
2017-12-01
We are developing a numerical simulator for future space weather forecast using magnetosphere-ionosphere coupling global MHD simulation called REPPU (REProduce Plasma Universe) code. We investigate the validity of the MHD simulation result as compared with observation. In this study we simulate some events including both quiet and disturbed geomagnetic conditions using OMNIWeb solar wind data. The simulation results are compared with magnetic field observations from Michibiki satellite, which is on the quasi-zenith orbit (QZO). In quiet geomagnetic condition, magnetic field variations at QZO obtained from simulation results have good consistency as compared correspondence with those from Michibiki observation. In disturbed geomagnetic condition in which the Dst < -20 nT, however, V component of magnetic field variations from simulation results tend to deviate from observations especially at the night side. We consider that this deviation during disturbed geomagnetic condition might be due to tail and/or ring current enhancement which is already suggested by many other MHD simulation studies as compared with the magnetic field observation at geosynchronous orbit. In this presentation, we will discuss the cause of this discrepancy in more detail with studying the relationship between the magnetic field deviation and some parameters such as Dst and solar wind.
Chang, Angela T; Palmer, Kerry R; McNaught, Jessie; Thomas, Peter J
2010-08-01
This study investigated the effect of flow rates and spirometer type on chest wall motion in healthy individuals. Twenty-one healthy volunteers completed breathing trials to either two times tidal volume (2xV(T)) or inspiratory capacity (IC) at high, low, or natural flow rates, using a volume- or flow-oriented spirometer. The proportions of rib cage movement to tidal volume (%RC/V(T)), chest wall diameters, and perceived level of exertion (RPE) were compared. Low and natural flow rates resulted in significantly lower %RC/V(T) compared to high flow rate trials (p=0.001) at 2xV(T). Low flow trials also resulted in significantly less chest wall motion in the upper anteroposterior direction than high and natural flow rates (p<0.001). At IC, significantly greater movement occurred in the abdominal lateral direction during low flow compared to high and natural flow trials (both p<0.003). RPE was lower for the low flow trials compared to high flow trials at IC and 2xV(T) (p<0.01). In healthy individuals, inspiratory flow (not device type) during incentive spirometry determines the resultant breathing pattern. High flow rates result in greater chest wall motion than low flow rates.
Chason, Juddson; Sausville, Justin; Kramer, Andrew C
2009-08-01
Some urologists choose not to offer penile prostheses because of concern over malpractice liability. The aim of this study was to assess whether urologists performing penile prosthesis surgery are placed at a greater malpractice risk. Percentage of malpractice suits from prosthesis surgery and other urological procedures that result in payment, average resulting payout from these cases, and category of legal issue that ultimately resulted in payout. A database from the Physician Insurers Association of America, an association of malpractice insurance companies covering physicians in North America, was analyzed to quantitatively compare penile implant surgery to other urological procedures in medicolegal terms. Compared to other common urological procedures, penile implant is comparable and on the lower end of the spectrum in terms of both the percentage of malpractice suits that result in payment and the amount ultimately paid in indemnity from those cases. Additionally, issues of informed consent play the largest role in indemnities for all urological procedures, whereas surgical technique is the most important issue for prosthesis surgery. Urologists who are adequately trained in prosthetic surgery should not avoid penile implant procedures for fear of malpractice suits. A focus on communication and informed consent can greatly reduce malpractice risk for urological procedures.
Metrics for comparing dynamic earthquake rupture simulations
Barall, Michael; Harris, Ruth A.
2014-01-01
Earthquakes are complex events that involve a myriad of interactions among multiple geologic features and processes. One of the tools that is available to assist with their study is computer simulation, particularly dynamic rupture simulation. A dynamic rupture simulation is a numerical model of the physical processes that occur during an earthquake. Starting with the fault geometry, friction constitutive law, initial stress conditions, and assumptions about the condition and response of the near‐fault rocks, a dynamic earthquake rupture simulation calculates the evolution of fault slip and stress over time as part of the elastodynamic numerical solution (Ⓔ see the simulation description in the electronic supplement to this article). The complexity of the computations in a dynamic rupture simulation make it challenging to verify that the computer code is operating as intended, because there are no exact analytic solutions against which these codes’ results can be directly compared. One approach for checking if dynamic rupture computer codes are working satisfactorily is to compare each code’s results with the results of other dynamic rupture codes running the same earthquake simulation benchmark. To perform such a comparison consistently, it is necessary to have quantitative metrics. In this paper, we present a new method for quantitatively comparing the results of dynamic earthquake rupture computer simulation codes.
Social inclusion of the people with mental health issues: Compare international results.
Santos, Jussara Carvalho Dos; Barros, Sônia; Huxley, Peter John
2018-06-01
Social inclusion of people with mental health issues is an aim of the World Health Organisation. Many countries have adopted that objective, including Brazil and the United Kingdom and both have focused treatment in the community. The aim of this article is to compare international results using the same inclusion instrument. The samples in this study were 225 people with mental health issues in community services in São Paulo, Brazil. Their results are compared to findings from 168 people with similar mental health issues in Hong Kong, China, and from the United Kingdom - a nationally representative sample of 212 people without mental health issues. The instrument used to measure a social inclusion called Social and Communities Opportunities Profile (SCOPE) has been validated for use in the United Kingdom, China and Brazil. The results are that people with mental health issues have worse social inclusion when compared to general population. Between the people with mental health issues, the sample of São Paulo has the lowest social inclusion index but, in relation to access to the Brazilian revised mental health services, that sample has a similarly high inclusion rating to the general population of the United Kingdom. Findings are important to understand mental health in the community context, as well as their adversities and potentialities.
Naguib, Ibrahim A; Abdelrahman, Maha M; El Ghobashy, Mohamed R; Ali, Nesma A
2016-01-01
Two accurate, sensitive, and selective stability-indicating methods are developed and validated for simultaneous quantitative determination of agomelatine (AGM) and its forced degradation products (Deg I and Deg II), whether in pure forms or in pharmaceutical formulations. Partial least-squares regression (PLSR) and spectral residual augmented classical least-squares (SRACLS) are two chemometric models that are being subjected to a comparative study through handling UV spectral data in range (215-350 nm). For proper analysis, a three-factor, four-level experimental design was established, resulting in a training set consisting of 16 mixtures containing different ratios of interfering species. An independent test set consisting of eight mixtures was used to validate the prediction ability of the suggested models. The results presented indicate the ability of mentioned multivariate calibration models to analyze AGM, Deg I, and Deg II with high selectivity and accuracy. The analysis results of the pharmaceutical formulations were statistically compared to the reference HPLC method, with no significant differences observed regarding accuracy and precision. The SRACLS model gives comparable results to the PLSR model; however, it keeps the qualitative spectral information of the classical least-squares algorithm for analyzed components.
Hosseinpour-Feizi, Hojjat; Soleimanpour, Jafar; Sales, Jafar Ganjpour; Arzroumchilar, Ali
2011-01-01
The aim of this study was to investigate the interobserver agreement of the Lenke and King classifications for adolescent idiopathic scoliosis, and to compare the results of surgery performed based on classification of the scoliosis according to each of these classification systems. The study was conducted in Shohada Hospital in Tabriz, Iran, between 2009 and 2010. First, a reliability assessment was undertaken to assess interobserver agreement of the Lenke and King classifications for adolescent idiopathic scoliosis. Second, postoperative efficacy and safety of surgery performed based on the Lenke and King classifications were compared. Kappa coefficients of agreement were calculated to assess the agreement. Outcomes were compared using bivariate tests and repeated measures analysis of variance. A low to moderate interobserver agreement was observed for the King classification; the Lenke classification yielded mostly high agreement coefficients. The outcome of surgery was not found to be substantially different between the two systems. Based on the results, the Lenke classification method seems advantageous. This takes into consideration the Lenke classification's priority in providing details of curvatures in different anatomical surfaces to explain precise intensity of scoliosis, that it has higher interobserver agreement scores, and also that it leads to noninferior postoperative results compared with the King classification method.
Surgical therapy of canine nasal tumors: A retrospective study (1982-1986)
Laing, Elizabeth J.; Binnington, Allen G.
1988-01-01
The results of surgical therapy in 15 dogs with histologically confirmed nasal tumors were analyzed retrospectively and compared to previous reports. Median survival time for all dogs was seven months. When adjusted for nontumor-related deaths, median survival increased to nine months. These values are two to three times longer than previous reports. To determine possible prognostic indicators, tumor stage, location, and histological type were compared to survival time. Dogs with unilateral nasal tumors had a median survival of 11 months, as compared to three months for dogs with bilateral tumors (p = 0.005). Tumor stage and histological type were not significant factors in comparing survival times. PMID:17423139
49 CFR 555.6 - Basis for application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... achieved either by design changes or termination of production of nonconforming vehicles; and (v) The total... failure to meet the standard, expressed as comparative performance levels; and (iv) Reasons why the... standard, expressed as comparative performance levels; (iv) The results of any tests conducted on the...
49 CFR 555.6 - Basis for application.
Code of Federal Regulations, 2013 CFR
2013-10-01
... achieved either by design changes or termination of production of nonconforming vehicles; and (v) The total... failure to meet the standard, expressed as comparative performance levels; and (iv) Reasons why the... standard, expressed as comparative performance levels; (iv) The results of any tests conducted on the...
49 CFR 555.6 - Basis for application.
Code of Federal Regulations, 2012 CFR
2012-10-01
... achieved either by design changes or termination of production of nonconforming vehicles; and (v) The total... failure to meet the standard, expressed as comparative performance levels; and (iv) Reasons why the... standard, expressed as comparative performance levels; (iv) The results of any tests conducted on the...
49 CFR 555.6 - Basis for application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... achieved either by design changes or termination of production of nonconforming vehicles; and (v) The total... failure to meet the standard, expressed as comparative performance levels; and (iv) Reasons why the... standard, expressed as comparative performance levels; (iv) The results of any tests conducted on the...
COMPARATIVE STUDY OF AIR CLASSIFIERS
This report describes the results of field tests of seven different air classifier systems. The systems are compared in regard to (a) their capacity to handle refuse and separate it into a heavy fraction and a light fuel fraction, (b) their ability to concentrate lights in the li...
49 CFR 555.6 - Basis for application.
Code of Federal Regulations, 2014 CFR
2014-10-01
... achieved either by design changes or termination of production of nonconforming vehicles; and (v) The total... failure to meet the standard, expressed as comparative performance levels; and (iv) Reasons why the... standard, expressed as comparative performance levels; (iv) The results of any tests conducted on the...
Biofilm formation by strains of Leuconostoc citreum and L. mesenteroides
USDA-ARS?s Scientific Manuscript database
Aims: To compare for the first time biofilm formation among strains of Leuconostoc citreum and L. mesenteroides that produce varying types of extracellular glucans. Methods and Results: Twelve strains of Leuconostoc sp. that produce extracellular glucans were compared for their capacity to produ...
Comparing State SAT Scores: Problems, Biases, and Corrections.
ERIC Educational Resources Information Center
Gohmann, Stephen F.
1988-01-01
One method to correct for selection bias in comparing Scholastic Aptitude Test (SAT) scores among states is presented, which is a modification of J. J. Heckman's Selection Bias Correction (1976, 1979). Empirical results suggest that sample selection bias is present in SAT score regressions. (SLD)
A Comparative Analysis for Wilderness User Fee Policy.
ERIC Educational Resources Information Center
Leuschner, William A.; And Others
1987-01-01
Two similar wilderness areas, one of which charges user fees, were sampled in order to compare user characteristics, trip characteristics, and travel cost demand functions. The purpose was to examine the effect fees had on user behavior and choices of area. Results are presented. (MT)
Classification of high dimensional multispectral image data
NASA Technical Reports Server (NTRS)
Hoffbeck, Joseph P.; Landgrebe, David A.
1993-01-01
A method for classifying high dimensional remote sensing data is described. The technique uses a radiometric adjustment to allow a human operator to identify and label training pixels by visually comparing the remotely sensed spectra to laboratory reflectance spectra. Training pixels for material without obvious spectral features are identified by traditional means. Features which are effective for discriminating between the classes are then derived from the original radiance data and used to classify the scene. This technique is applied to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data taken over Cuprite, Nevada in 1992, and the results are compared to an existing geologic map. This technique performed well even with noisy data and the fact that some of the materials in the scene lack absorption features. No adjustment for the atmosphere or other scene variables was made to the data classified. While the experimental results compare favorably with an existing geologic map, the primary purpose of this research was to demonstrate the classification method, as compared to the geology of the Cuprite scene.
Disseminating Comparative Effectiveness Research Through Community-based Experiential Learning.
Hansen, Richard A; Williamson, Margaret; Stevenson, Lynn; Davis, Brandy R; Evans, R Lee
2017-02-25
Objectives. To launch and evaluate a comparative effectiveness research education and dissemination program as part of an introductory pharmacy practice experience (IPPE). Methods. First- through third-year PharmD students received training on comparative effectiveness research and disseminated printed educational materials to patients in the community who they were monitoring longitudinally (n=314). Students completed an assessment and initial visit documentation form at the first visit, and a follow-up assessment and documentation form at a subsequent visit. Results. Twenty-three diabetes patients, 29 acid-reflux patients, 30 osteoarthritis patients, and 50 hypertension patients received materials. Aside from the patient asking questions, which was the most common outcome (n=44), the program resulted in 38 additional actions, which included stopping, starting, or changing treatments or health behaviors, or having additional follow-up or diagnostic testing. Small but positive improvements in patient understanding, confidence, and self-efficacy were observed. Conclusions. Dissemination of comparative effectiveness research materials in an IPPE program demonstrated a positive trend in markers of informed decision-making.
Benchmarking comparison and validation of MCNP photon interaction data
NASA Astrophysics Data System (ADS)
Colling, Bethany; Kodeli, I.; Lilley, S.; Packer, L. W.
2017-09-01
The objective of the research was to test available photoatomic data libraries for fusion relevant applications, comparing against experimental and computational neutronics benchmarks. Photon flux and heating was compared using the photon interaction data libraries (mcplib 04p, 05t, 84p and 12p). Suitable benchmark experiments (iron and water) were selected from the SINBAD database and analysed to compare experimental values with MCNP calculations using mcplib 04p, 84p and 12p. In both the computational and experimental comparisons, the majority of results with the 04p, 84p and 12p photon data libraries were within 1σ of the mean MCNP statistical uncertainty. Larger differences were observed when comparing computational results with the 05t test photon library. The Doppler broadening sampling bug in MCNP-5 is shown to be corrected for fusion relevant problems through use of the 84p photon data library. The recommended libraries for fusion neutronics are 84p (or 04p) with MCNP6 and 84p if using MCNP-5.
Psychosis in autism: comparison of the features of both conditions in a dually affected cohort†
Larson, Felicity V.; Wagner, Adam P.; Jones, Peter B.; Tantam, Digby; Lai, Meng-Chuan; Baron-Cohen, Simon; Holland, Anthony J.
2017-01-01
Background There is limited information on the presentation and characteristics of psychotic illness experienced by people with autism spectrum disorder (ASD). Aims To describe autistic and psychotic phenomenology in a group of individuals with comorbid ASD and psychosis (ASD–P) and compare this group with populations affected by either, alone. Method We studied 116 individuals with ASD–P. We compared features of their ASD with people with ASD and no comorbid psychosis (ASD–NP), and clinical characteristics of psychosis in ASD–P with people with psychosis only. Results Individuals with ASD–P had more diagnoses of atypical psychosis and fewer of schizophrenia compared with individuals with psychosis only. People with ASD–P had fewer stereotyped interests/behaviours compared with those with ASD–NP. Conclusions Our data show there may be a specific subtype of ASD linked to comorbid psychosis. The results support findings that psychosis in people with ASD is often atypical, particularly regarding affective disturbance. PMID:27979819
Sleep and EEG Spectra in Rats Recorded via Telemetry during Surgical Recovery
Tang, Xiangdong; Yang, Linghui; Sanford, Larry D.
2007-01-01
Study Objective: To determine sleep and EEG spectra in rats during surgical recovery. Design: Sleep, activity, and EEG spectral power were examined in rats via telemetry on days 1, 2, 3, 7, 14, and 15 after implantation surgery. Results: NREM sleep and total sleep were increased on days 1 and 2 compared to later days. REM sleep was decreased on days 2 and 3 compared to days 14 and 15, and activity was decreased on days 1 and 2 compared to later days. EEG power (0.5–5 Hz for NREM and wakefulness, and 5.5–10 Hz for REM and wakefulness) was increased on days 1–3 compared to days 7, 14, and 15. Conclusion: The results are discussed in terms of their implications for post-surgery stabilization of sleep and potential relevance for sleep after injury. Citation: Tang X; Yang L; Sanford LD. Sleep and EEG spectra in rats recorded via telemetry during surgical recovery. SLEEP 2007;30(8):1057-1061. PMID:17702276
NASA Astrophysics Data System (ADS)
Vrakatseli, V. E.; Amanatides, E.; Mataras, D.
2016-03-01
TiOx and TiOx-like thin films were deposited on PEEK (Polyether ether ketone) substrates by low-temperature RF reactive magnetron sputtering and the sol-gel method. The resulting films were compared in terms of their properties and photoinduced hydrophilicity. Both techniques resulted in uniform films with good adhesion that can be switched to superhydrophilic after exposure to UVA radiation for similar time periods. In addition, the sputtered films can also be activated and switched to superhydrophilic by natural sunlight due to the higher absorption in the visible spectrum compared to the sol-gel films. On the other hand, the as deposited sol-films remain relatively hydrophilic for a longer time in dark compared to the sputtered film due to the differences in the morphology and the porosity of the two materials. Thus, depending on the application, either method can be used in order to achieve the desirable TiOx properties.
Comparative optimism about healthy eating.
Sproesser, Gudrun; Klusmann, Verena; Schupp, Harald T; Renner, Britta
2015-07-01
The present study investigated people's perception of their own as compared to their peers' healthy eating and related these perceptions to actual healthy eating, BMI, and subsequent healthy eating behavior. Data were collected within the framework of the longitudinal cohort study Konstanz Life Study (T1: N = 770; T2: N = 510). Our results demonstrated an optimistic bias on the group level. Specifically, people rated their own eating behavior as healthier on average than that of their average peers. This comparative optimism occurred even when actual healthy eating was unfavorable and BMI was high. However, it increased with actual healthy eating behavior. Importantly, optimistic perceptions were positively related to the intention to eat healthily and healthy eating six months later. Hence, the results suggest that an optimistic comparative view of one's own healthy eating is grounded in reality and boosts rather than deters subsequent health behavior. This implies that there might not be a need to reduce optimistic perceptions of healthy eating behavior. Copyright © 2015 Elsevier Ltd. All rights reserved.
Patwardhan, Vrushali; Bhalla, Preena; Rawat, Deepti; Garg, Vijay Kumar; Sardana, Kabir; Sethi, Sumit
2017-01-01
To compare laboratory tests that can simultaneously detect and type herpes simplex virus (HSV) directly from the genital ulcer specimens in clinically suspected cases of genital herpes. A study was conducted over 10 months and 44 adult male and female patients clinically suspected with genital herpes were recruited. Genital ulcer swab specimens were subjected to glycoprotein-G gene-based conventional polymerase chain reaction (PCR) and commercially available direct fluorescent antibody (DFA) test and the results were compared. PCR for HSV was positive in 82% (36/44) cases. DFA was positive in 68.2% (30/44) cases. There was 100% agreement between HSV types detected by DFA and PCR. The strength of agreement between the results was better in primary genital herpes than recurrent cases. PCR was found to be better in the detection of HSV in recurrent genital herpes patients. It is a better modality, especially when genital herpes clinically presents with ulcerative or crusted lesions, and is also a cheaper alternative as compared to DFA.
Korobko, Igor V; Lomonosov, Konstantin M
2016-11-01
Prostaglandins and their analogues are beneficial as topical agents in vitiligo treatment, yet neither of the previous study addressed their comparative efficiency with conventional topical agents used in vitiligo treatment. In this pilot (24 patients) left-right comparative study we addressed efficiency of prostaglandin F2α analogue latanoprost versus tacrolimus when combined with narrow-band ultraviolet B and microneedling in repigmentation of nonsegmental vitiligo lesions. Our results confirm potency of prostaglandins, in particular, that of latanoprost, in inducing repigmentation, with the efficiency being at least comparable to that of tacrolimus, while contribution of microneedling remains unclear. In summary, results of our study provide further evidences for justified use of prostaglandins, in particular, latanoprost, in vitiligo treatment. In turn, this warrants future studies on the topic aiming to conclusively introduce prostaglandin-based formulations as conventional agents for vitiligo management. © 2016 Wiley Periodicals, Inc.
Brewer, Judson A.; Sinha, Rajita; Chen, Justin A.; Michalsen, Ravenna N.; Babuscio, Theresa A.; Nich, Charla; Grier, Aleesha; Bergquist, Keri L.; Reis, Deidre L.; Potenza, Marc N.; Carroll, Kathleen M.; Rounsaville, Bruce J.
2011-01-01
Background Stress is important in substance use disorders (SUDs). Mindfulness training (MT) has shown promise for stress-related maladies. No studies have compared MT to empirically-validated treatments for SUDs. Goals to assess MT compared to cognitive behavioral therapy (CBT) in substance use and treatment acceptability, and specificity of MT compared to CBT in targeting stress reactivity. Methods 36 individuals with alcohol and/or cocaine use disorders were randomly assigned to receive group MT or CBT in an outpatient setting. Drug use was assessed weekly. After treatment, responses to personalized stress provocation were measured. Results Fourteen individuals completed treatment. There were no differences in treatment satisfaction, or drug use between groups. The laboratory paradigm suggested reduced psychological and physiological indices of stress during provocation in MT compared to CBT. Conclusions This pilot study provides evidence of the feasibility of MT in treating SUDs and suggests that MT may be efficacious in targeting stress. PMID:19904666
Suppaphol, Sorasak; Worathanarat, Patarawan; Kawinwongkovit, Viroj; Pittayawutwinit, Preecha
2012-04-01
To compare the operative outcome of carpal tunnel release between limited open carpal tunnel release using direct vision and tunneling technique (group A) with standard open carpal tunnel release (group B). Twenty-eight patients were enrolled in the present study. A single blind randomized control trial study was conducted to compare the postoperative results between group A and B. The study parameters were Levine's symptom severity and functional score, grip and pinch strength, and average two-point discrimination. The postoperative results between two groups were comparable with no statistical significance. Only grip strength at three months follow up was significantly greater in group A than in group B. The limited open carpal tunnel release in the present study is effective comparable to the standard open carpal tunnel release. The others advantage of this technique are better cosmesis and improvement in grip strength at the three months postoperative period.
Some Biochemical and Hematological Parameters among Petrol Station Attendants: A Comparative Study
Abou-ElWafa, Hala Samir; Albadry, Ahmed A.; Bazeed, Fagr B.
2015-01-01
Objective. To describe selected biochemical and hematological parameters (blood picture, liver enzymes, and kidney functions) in petrol station attendants in Mansoura city. Methods. This is a comparative cross-sectional study. The exposed group included 102 petrol station attendants. They were compared to a matched group of healthy 102 male service and office workers at the Faculty of Medicine, Mansoura University. The results of blood picture, liver enzymes, and kidney functions were compared between both groups. Results. Mean Red Blood Cells (RBCs) count, hemoglobin level, and Hematocrit (HCT) level were significantly lower in petrol station attendants than the comparison group. All other blood picture parameters showed nonsignificant difference between both groups. Liver enzymes, renal functions, serum albumin, and total protein showed statistically nonsignificant difference between both groups except for alanine aminotransferase (ALT) which was significantly higher in petrol station attendants. Conclusions. Some laboratory parameters among petrol station attendants showed changes that could be attributed to workplace exposure and should be given attention at preemployment and periodic medical examination. PMID:26634207
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ojanen, M.; Hahtela, O. M.; Heinonen, M.
MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one ofmore » the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.« less
Comparability of outcome frameworks in medical education: Implications for framework development.
Hautz, Stefanie C; Hautz, Wolf E; Feufel, Markus A; Spies, Claudia D
2015-01-01
Given the increasing mobility of medical students and practitioners, there is a growing need for harmonization of medical education and qualifications. Although several initiatives have sought to compare national outcome frameworks, this task has proven a challenge. Drawing on an analysis of existing outcome frameworks, we identify factors that hinder comparability and suggest ways of facilitating comparability during framework development and revisions. We searched MedLine, EmBase and the Internet for outcome frameworks in medical education published by national or governmental organizations. We analyzed these frameworks for differences and similarities that influence comparability. Of 1816 search results, 13 outcome frameworks met our inclusion criteria. These frameworks differ in five core features: history and origins, formal structure, medical education system, target audience and key terms. Many frameworks reference other frameworks without acknowledging these differences. Importantly, the level of detail of the outcomes specified differs both within and between frameworks. The differences identified explain some of the challenges involved in comparing outcome frameworks and medical qualifications. We propose a two-level model distinguishing between "core" competencies and culture-specific "secondary" competencies. This approach could strike a balance between local specifics and cross-national comparability of outcome frameworks and medical education.
Crystallization and textural porosity of synthetic clay minerals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carrado, K. A.; Csencsits, R.; Thiyagarajan, P.
2002-12-01
The crystallization of synthetic layered magnesium silicate hectorite clays from both silica sol and organosilane sources is compared. For the silica sol-derived clays, a templating method is employed wherein organic or polymeric molecules are included during clay crystallization that are then removed from the composites via calcination. The mechanism of silane-derived hectorite formation is followed by XRD, TGA, 29Si MAS NMR, and small angle X-ray scattering (SAXS), and results are compared to those obtained for the sol-derived hectorite. The mechanism appears to be similar but the rate is approximately doubled when the silane is used rather than silica sol. Analyticalmore » transmission electron microscopy (TEM) is exploited to glean structural morphology information towards resolving the nature of the resulting pore network structures. Results are compared with nitrogen adsorption-desorption isotherm behavior; dominant hysteresis loops are present in the type IV isotherms. Pore size distributions based on both the adsorption and desorption isotherms are compared. Small angle neutron scattering (SANS) experiments reveal that the average particle size increases as synthetic laponite < sol-derived hectorite < silane-derived hectorite < natural hectorite. Contrast matching SANS studies in aqueous and organic solvents are carried out to extract information about pore accessibility.« less
Telerehabilitation in poststroke anomia.
Agostini, Michela; Garzon, Martina; Benavides-Varela, Silvia; De Pellegrin, Serena; Bencini, Giulia; Rossi, Giulia; Rosadoni, Sara; Mancuso, Mauro; Turolla, Andrea; Meneghello, Francesca; Tonin, Paolo
2014-01-01
Anomia, a word-finding difficulty, is a frequent consequence of poststroke linguistic disturbance, associated with fluent and nonfluent aphasia that needs long-term specific and intensive speech rehabilitation. The present study explored the feasibility of telerehabilitation as compared to a conventional face-to-face treatment of naming, in patients with poststroke anomia. Five aphasic chronic patients participated in this study characterized by: strictly controlled crossover design; well-balanced lists of words in picture-naming tasks where progressive phonological cues were provided; same kind of the treatment in the two ways of administration. ANOVA was used to compare naming accuracy in the two types of treatment, at three time points: baseline, after treatment, and followup. The results revealed no main effect of treatment type (P = 0.844) indicating that face-to-face and tele-treatment yielded comparable results. Moreover, there was a significant main effect of time (P = 0.0004) due to a better performance immediately after treatment and in the followup when comparing them to baseline. These preliminary results show the feasibility of teletreatment applied to lexical deficits in chronic stroke patients, extending previous work on telerehabilitation and opening new vistas for future studies on teletreatment of language functions.
Coherence bandwidth loss in transionospheric radio propagation
NASA Technical Reports Server (NTRS)
Rino, C. L.; Gonzalez, V. H.; Hessing, A. R.
1980-01-01
In this report a theoretical model is developed that predicts the single-point, two-frequency coherence function for transionospheric radio waves. The theoretical model is compared to measured complex frequency correlation coefficients using data from the seven equispaced, phase-coherent UHF signals transmitted by the Wideband satellite. The theory and data are in excellent agreement. The theory is critically dependent upon the power-law index, and the frequency coherence data clearly favor the comparatively small spectral indices that have been consistently measured from the wideband satellite phase data. A model for estimating the pulse delay jitter induced by the coherence bandwidth loss is also developed and compared with the actual delay jitter observed on synthesized pulses obtained from the Wideband UFH comb. The results are in good agreement with the theory. The results presented in this report, which are based on an asymptotic theory, are compared with the more commonly used quadratic theory. The model developed and validated in this report can be used to predict the effects of coherence bandwidth loss in disturbed nuclear environments. Simple formulas for the resultant pulse delay jitter are derived that can be used in predictive codes.
NASA Astrophysics Data System (ADS)
Sivakumar, A.; Alagumurthi, N.; Senthilvelan, T.
2016-07-01
The microchannels are device used to remove high heat fluxes from smaller area. In this experimental research work the heat transfer performance of nanofluids of Al2O3/water and CuO/water were compared. The important character of such fluids is the enhanced thermal conductivity, in comparison with base fluid without considerable alteration in physical and chemical properties. The effect of forced convective heat transfer coefficient was calculated using serpentine shaped microchannel heat exchanger. Furthermore we calculated the forced convective heat transfer coefficient of the nanofluids using theoretical correlations in order to compare the results with the experimental data. The heat transfer coefficient for different particle concentration and temperature were analysed using forced convection heat transfer using nanofluids. The findings indicate considerable enhancement in convective heat transfer coefficient of the nanofluids as compared to the basefluid. The results also shows that CuO/water nanofluid has increased heat transfer coefficient compared with Al2O3/water and base fluids. Moreover the experimental results indicate there is increased forced convective heat transfer coefficient with the increase in nano particle concentration.
Graefe, H; Wollenberg, B; Brocks, C
2008-09-01
In this work cyanoacrylate-based skin adhesives used in Germany for skin closure in head and neck surgery are compared with respect to ease of application, cost-effectiveness and cosmetic results. We compared 25 wounds sealed with a skin adhesive with 25 suture-sealed wounds. Bonding of surgical wounds with glue had a high level of acceptance in all patients. The tedious, time-consuming and sometimes painful postoperative removal of many sutures in patients is omitted. Patients can shower soon afterwards without additional protection as the adhesive provides a waterproof barrier. Problems of wound healing can immediately be detected through the transparent skin adhesive. Cosmetic long-term results of skin closure by adhesives are comparable to suture-sealed wounds. The adhesives available on the market differ mainly in the form of the applicator, the viscosity on application, as well as the strength after hardening. The application is easy to implement and significantly faster than conventional suturing. Apart from the cost savings of materials compared to the use of skin sutures and investment of Steri-Strips, expensive anesthesia and surgical time can also be saved.
Cadieux, Nathalie; Marchand, Alain
2014-01-01
Although several studies are concerned by the phenomenon of psychological distress at work, few studies have looked at the prevalence of psychological distress among professional workers in the regulated occupations and compare this prevalence with other occupations. This study propose to define regulated occupations by laying out the theoretical boundaries that apply to the practice of these occupations and try to understand how regulated occupations contributed to the experience of psychological distress in the Canadian workforce over time. Multilevel logistical regression analyses on longitudinal data were performed to compare the odds of experiencing psychological distress over time among professional workers in regulated occupations (n=276) and among other professional workers, classified into 6 categories (n=6731), over a 12-year period. The results show that proportion of distress in the workforce decreases for all occupations between Cycle 1 and Cycle 7 of the NPHS, but this decrease is not linear over time. The results show also that regulated occupations present a lower probability of psychological distress only when compared with white-collar workers. These results suggest that occupation contributes little toward understanding the prevalence of psychological distress in the Canadian workforce. Further research needs are also discussed.
Cystic fibrosis epithelial cells are primed for apoptosis as a result of increased Fas (CD95).
Chen, Qiwei; Pandi, Sudha Priya Soundara; Kerrigan, Lauren; McElvaney, Noel G; Greene, Catherine M; Elborn, J Stuart; Taggart, Clifford C; Weldon, Sinéad
2018-02-24
Previous work suggests that apoptosis is dysfunctional in cystic fibrosis (CF) airways with conflicting results. We evaluated the relationship between dysfunctional cystic fibrosis transmembrane conductance regulator (CFTR) and apoptosis in CF airway epithelial cells. Apoptosis and associated caspase activity were analysed in non-CF and CF tracheal and bronchial epithelial cell lines. Basal levels of apoptosis and activity of caspase-3 and caspase-8 were significantly increased in CF epithelial cells compared to controls, suggesting involvement of extrinsic apoptosis signalling, which is mediated by the activation of death receptors, such as Fas (CD95). Increased levels of Fas were observed in CF epithelial cells and bronchial brushings from CF patients compared to non-CF controls. Neutralisation of Fas significantly inhibited caspase-3 activity in CF epithelial cells compared to untreated cells. In addition, activation of Fas significantly increased caspase-3 activity and apoptosis in CF epithelial cells compared to control cells. Overall, these results suggest that CF airway epithelial cells are more sensitive to apoptosis via increased levels of Fas and subsequent activation of the Fas death receptor pathway, which may be associated with dysfunctional CFTR. Copyright © 2018 European Cystic Fibrosis Society. All rights reserved.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do
2018-01-01
Introduction Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser. PMID:29619098
Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do
2018-04-01
Introduction Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser.
[First-generation immigrant adolescents' physical and mental health and behaviors].
Noirhomme-Renard, F; Deccache, A
2007-08-01
The objectives of this article are to: a) review literature about physical, mental health and behaviors of first generation immigrant adolescents and its evolution; b) compare first and second generations immigrant adolescents'health. Studies usually compare first generation and others adolescents groups: 1) first generation adolescents shows better physical health and behaviors than second generation; 2) first generation adolescents shows variable results for mental health compared to second generation and host adolescents according to the studies; 3) a degradation of physical health and behaviors is observed with the time passed in the host country. These results show necessity of a precocious evaluation of first generation adolescents' needs for a good planification of health promotion and prevention actions to preserve their health advantage at arrival.
Boggia, B; Graziuso, G; Carbone, U
2011-01-01
Aim of the study is to evaluate the effect of specific information program on DPI use on the functional respiratory parameters in a group of 15 welders compared with 18 welders not included in the program and 18 workers of industrial sector. Spirometryc parameters were recorded and compared and the results pointed out a significant increase of FEV1 and FVC in the study group compared with welder out of the study while no difference were observed between study group and workers of industrial sector. Results shown that the correct use of DPI could reduce the effects of welding fumes on respiratory tract making these effects equal to the exposure to industrial dusts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, W.E.
1999-02-10
Evolutionary programs (EPs) and evolutionary pattern search algorithms (EPSAS) are two general classes of evolutionary methods for optimizing on continuous domains. The relative performance of these methods has been evaluated on standard global optimization test functions, and these results suggest that EPSAs more robustly converge to near-optimal solutions than EPs. In this paper we evaluate the relative performance of EPSAs and EPs on a real-world application: flexible ligand binding in the Autodock docking software. We compare the performance of these methods on a suite of docking test problems. Our results confirm that EPSAs and EPs have comparable performance, and theymore » suggest that EPSAs may be more robust on larger, more complex problems.« less
NASA Astrophysics Data System (ADS)
Sousa, Andre R.; Schneider, Carlos A.
2001-09-01
A touch probe is used on a 3-axis vertical machine center to check against a hole plate, calibrated on a coordinate measuring machine (CMM). By comparing the results obtained from the machine tool and CMM, the main machine tool error components are measured, attesting the machine accuracy. The error values can b used also t update the error compensation table at the CNC, enhancing the machine accuracy. The method is easy to us, has a lower cost than classical test techniques, and preliminary results have shown that its uncertainty is comparable to well established techniques. In this paper the method is compared with the laser interferometric system, regarding reliability, cost and time efficiency.
Dutch home-based pre-reading intervention with children at familial risk of dyslexia.
van Otterloo, Sandra G; van der Leij, Aryan
2009-12-01
Children (5 and 6 years old, n = 30) at familial risk of dyslexia received a home-based intervention that focused on phoneme awareness and letter knowledge in the year prior to formal reading instruction. The children were compared to a no-training at-risk control group (n = 27), which was selected a year earlier. After training, we found a small effect on a composite score of phoneme awareness (d = 0.29) and a large effect on receptive letter knowledge (d = 0.88). In first grade, however, this did not result in beneficial effects for the experimental group in word reading and spelling. Results are compared to three former intervention studies in The Netherlands and comparable studies from Denmark and Australia.
Superconductive ADC Project Fabrication Package. Final Design Review Package (Briefing Charts)
2010-09-07
Simulation Results Iin 1.45mV 2.5Ω 1pH 4pH 100fF 310uA 1fΩ Ic = 300uA Rn = 0.8Ω Cs = 0.32pF Ic = 300uA Rn = 0.8Ω Cs = 0.32pF Iin Vout Vout Ic = 500uA Rn...0.55Ω Cs = 0.32pF ONR Superconductive ADC CLIN/SLIN 0001AD September 2010, Brad Perranoski Pg. 17 Modulator Design Documentation Comparator Design...Comparator Design - Cadence Schematic & Simulation Comparator Testbench Simulation Results 1.45mV 2.5Ω 1pH 4pH 100fF 310uA 1fΩSine wave 100uApk Iin Ic
2011-01-01
Background The aim of the present study was to assess the performance of three primary care-led initiatives providing structured care to patients with Type 2 diabetes in Ireland, a country with minimal incentives to promote the quality of care. Methods Data, from three primary care initiatives, were available for 3010 adult patients with Type 2 diabetes. Results were benchmarked against the national guidelines for the management of Type 2 diabetes in the community and results from the National Diabetes Audit (NDA) for England (2008/2009) and the Scottish Diabetes Survey (2009). Results The recording of clinical processes of care was similar to results in the UK however the recording of lifestyle factors was markedly lower. Recording of HbA1c, blood pressure and lipids exceeded 85%. Recording of retinopathy screening (71%) was also comparable to England (77%) and Scotland (90%). Only 63% of patients had smoking status recorded compared to 99% in Scotland while 70% had BMI recorded compared to 89% in England. A similar proportion of patients in this initiative and the UK achieved clinical targets. Thirty-five percent of patients achieved a target HbA1c of < 6.5% (< 48 mmol/mol) compared to 25% in England. Applying the NICE target for blood pressure (≤ 140/80 mmHg), 54% of patients reached this target comparable to 60% in England. Slightly less patients were categorised as obese (> 30 kg/m2) in Ireland (50%, n = 1060) compared to Scotland (54%). Conclusions This study has demonstrated what can be achieved by proactive and interested health professionals in the absence of national infrastructure to support high quality diabetes care. The quality of primary care-led diabetes management in the three initiatives studied appears broadly consistent with results from the UK with the exception of recording lifestyle factors. The challenge facing health systems is to establish quality assurance a responsibility for all health care professionals rather than the subject of special interest for a few. PMID:22204759
Gion, M; Mione, R; Leon, A E; Lüftner, D; Molina, R; Possinger, K; Robertson, J F
2001-02-01
Recently, a fully automated method has become commercially available to measure the MUC-1-associated antigen CA27.29. The present investigation was performed in order to compare CA27.29 and CA15.3 in a wide series of patients affected with breast cancer. Overall, 603 cases with breast cancer and 194 healthy controls were investigated. Patients were enrolled in 4 institutions, while assays were performed in one laboratory. CA27.29 was measured by the ACS:180 BR assay (Bayer Diagnostics) and CA15.3 by the AxSYM (Abbott Laboratories). An excellent correlation was found between the results obtained by the two methods. The two markers showed comparable results in healthy controls, with higher levels in post-menopausal than in pre-menopausal subjects. The markers were significantly higher in primary breast cancer than in controls. The areas under the receiver operating characteristics (ROC) curves of the two tests were comparable, but CA27.29 showed better sensitivity in cases with low antigen concentrations (below the cut-off point). Accordingly, when comparing each test in different stage categories, significance levels of the differences were higher for CA27.29 than for CA15.3 for all T categories versus healthy controls, for pT1 versus pT2, for all N categories versus healthy controls and for node-negative versus N1-3 patients. From the results of the present study, that has been performed on samples taken at diagnosis and prior to any treatment from the widest series of patients with primary breast cancer reported so far, we can draw the following conclusions: CA27.29 provides comparable results to CA15.3; CA27.29 seems more sensitive than CA15.3 to limited variations of tumour extension; however, it cannot help clinicians in distinguishing stage I patients from stage II patients. However, from the point of view of clinical decision making, CA27.29 provides comparable results to CA15.3. CA27.29 is therefore suitable for routine use in the management of patients with breast cancer.
OTG-snpcaller: An Optimized Pipeline Based on TMAP and GATK for SNP Calling from Ion Torrent Data
Huang, Wenpan; Xi, Feng; Lin, Lin; Zhi, Qihuan; Zhang, Wenwei; Tang, Y. Tom; Geng, Chunyu; Lu, Zhiyuan; Xu, Xun
2014-01-01
Because the new Proton platform from Life Technologies produced markedly different data from those of the Illumina platform, the conventional Illumina data analysis pipeline could not be used directly. We developed an optimized SNP calling method using TMAP and GATK (OTG-snpcaller). This method combined our own optimized processes, Remove Duplicates According to AS Tag (RDAST) and Alignment Optimize Structure (AOS), together with TMAP and GATK, to call SNPs from Proton data. We sequenced four sets of exomes captured by Agilent SureSelect and NimbleGen SeqCap EZ Kit, using Life Technology’s Ion Proton sequencer. Then we applied OTG-snpcaller and compared our results with the results from Torrent Variants Caller. The results indicated that OTG-snpcaller can reduce both false positive and false negative rates. Moreover, we compared our results with Illumina results generated by GATK best practices, and we found that the results of these two platforms were comparable. The good performance in variant calling using GATK best practices can be primarily attributed to the high quality of the Illumina sequences. PMID:24824529
OTG-snpcaller: an optimized pipeline based on TMAP and GATK for SNP calling from ion torrent data.
Zhu, Pengyuan; He, Lingyu; Li, Yaqiao; Huang, Wenpan; Xi, Feng; Lin, Lin; Zhi, Qihuan; Zhang, Wenwei; Tang, Y Tom; Geng, Chunyu; Lu, Zhiyuan; Xu, Xun
2014-01-01
Because the new Proton platform from Life Technologies produced markedly different data from those of the Illumina platform, the conventional Illumina data analysis pipeline could not be used directly. We developed an optimized SNP calling method using TMAP and GATK (OTG-snpcaller). This method combined our own optimized processes, Remove Duplicates According to AS Tag (RDAST) and Alignment Optimize Structure (AOS), together with TMAP and GATK, to call SNPs from Proton data. We sequenced four sets of exomes captured by Agilent SureSelect and NimbleGen SeqCap EZ Kit, using Life Technology's Ion Proton sequencer. Then we applied OTG-snpcaller and compared our results with the results from Torrent Variants Caller. The results indicated that OTG-snpcaller can reduce both false positive and false negative rates. Moreover, we compared our results with Illumina results generated by GATK best practices, and we found that the results of these two platforms were comparable. The good performance in variant calling using GATK best practices can be primarily attributed to the high quality of the Illumina sequences.
Papageorgiou, Spyridon N; Kloukos, Dimitrios; Petridis, Haralampos; Pandis, Nikolaos
2015-10-01
To assess the hypothesis that there is excessive reporting of statistically significant studies published in prosthodontic and implantology journals, which could indicate selective publication. The last 30 issues of 9 journals in prosthodontics and implant dentistry were hand-searched for articles with statistical analyses. The percentages of significant and non-significant results were tabulated by parameter of interest. Univariable/multivariable logistic regression analyses were applied to identify possible predictors of reporting statistically significance findings. The results of this study were compared with similar studies in dentistry with random-effects meta-analyses. From the 2323 included studies 71% of them reported statistically significant results, with the significant results ranging from 47% to 86%. Multivariable modeling identified that geographical area and involvement of statistician were predictors of statistically significant results. Compared to interventional studies, the odds that in vitro and observational studies would report statistically significant results was increased by 1.20 times (OR: 2.20, 95% CI: 1.66-2.92) and 0.35 times (OR: 1.35, 95% CI: 1.05-1.73), respectively. The probability of statistically significant results from randomized controlled trials was significantly lower compared to various study designs (difference: 30%, 95% CI: 11-49%). Likewise the probability of statistically significant results in prosthodontics and implant dentistry was lower compared to other dental specialties, but this result did not reach statistical significant (P>0.05). The majority of studies identified in the fields of prosthodontics and implant dentistry presented statistically significant results. The same trend existed in publications of other specialties in dentistry. Copyright © 2015 Elsevier Ltd. All rights reserved.
A comparative study of aluminum and steel culverts : progress report no. 4.
DOT National Transportation Integrated Search
1971-01-01
The results of a comparative study of aluminum and steel culverts at six test sites throughout Virginia indicate that satisfactory durability can be expected of aluminum pipe under exposure to most of the soil and water conditions in the state. The p...
Education Policy Outlook: Denmark
ERIC Educational Resources Information Center
Pont, Beatriz; Figueroa, Diana Toledo; Albiser, Etienne; Yee, Hyo Jeong; Skalde, Annette; Zapata, Juliana; Fraccola, Sylvain
2014-01-01
This policy profile on education in Denmark is part of the new Education Policy Outlook series, which will present comparative analysis of education policies and reforms across OECD countries. Building on the substantial comparative and sectorial policy knowledge base available within the OECD, the series will result in a biennial publication…
Life-Cycle Assessment of Cookstove Fuels in India and China
A life cycle assessment (LCA) was conducted to compare the environmental footprint of current and possible fuels used for cooking within China and India. Current fuel mix profiles are compared to scenarios of projected differences in and/or cleaner cooking fuels. Results are repo...
Children's Comprehension of Comparative Forms
ERIC Educational Resources Information Center
Townsend, David J.
1974-01-01
Preschool children were tested on their comprehension of the comparatives, "taller,""shorter,""more," and "less" in five types of sentences. Results suggest that many children can understand two-dimensional comparisons, but perform poorly on second-clause subjects pronoun sentences because of uncertainty about the referent of the pronoun. (SDH)
Social Networks and Mourning: A Comparative Approach.
ERIC Educational Resources Information Center
Rubin, Nissan
1990-01-01
Suggests using social network theory to explain varieties of mourning behavior in different societies. Compares participation in funeral ceremonies of members of different social circles in American society and Israeli kibbutz. Concludes that results demonstrated validity of concepts deriving from social network analysis in study of bereavement,…
ERIC Educational Resources Information Center
Fahey, Thomas D.; And Others
1977-01-01
Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)
California Makes the Case for Pay Equity.
ERIC Educational Resources Information Center
Turner, Anne M.
2002-01-01
Discusses results of a California Library Association study that investigated library employees' salaries as compared to salaries of employees in comparable public jobs. Highlights include reasons for unfair library employee compensation; comparisons of support staff supervisor salaries and executive salaries; and how to use the data to improve…
Paracetamol suppositories: a comparative study.
Cullen, S; Kenny, D; Ward, O C; Sabra, K
1989-01-01
Paracetamol suppositories in two different bases were given to children who had fever after operations. Plasma concentrations and the effect on temperature were compared. There was a significant correlation between peak plasma concentrations and maximum drop in temperature. A lipophilic base produced better results than a hydrophilic base. PMID:2817936
COMPARATIVE ANALYSIS OF HEALTH RISK ASSESSMENTS FOR MUNICIPAL WASTE COMBUSTORS
Quantitative health risk assessments have been performed for a number of proposed municipal waste combustor (MWC) facilities over the past several years. his article presents the results of a comparative analysis of a total of 21 risk assessments, focusing on seven of the most co...
Eichler, Klaus; Urner, Martin; Twerenbold, Claudia; Kern, Sabine; Brügger, Urs; Spahn, Donat R; Beck-Schimmer, Beatrice; Ganter, Michael T
2017-03-01
Pharmacologic pre- and postconditioning with sevoflurane compared with total IV anesthesia in patients undergoing liver surgery reduced complication rates as shown in 2 recent randomized controlled trials. However, the potential health economic consequences of these different anesthesia regimens have not yet been assessed. An expostcost analysis of these 2 trials in 129 patients treated between 2006 and 2010 was performed. We analyzed direct medical costs for in-hospital stay and compared pharmacologic pre- and postconditioning with sevoflurane (intervention) with total IV anesthesia (control) from the perspective of a Swiss university hospital. Year 2015 costs, converted to US dollars, were derived from hospital cost accounting data and compared with a multivariable regression analysis adjusting for relevant covariables. Costs with negative prefix indicate savings and costs with positive prefix represent higher spending in our analysis. Treatment-related costs per patient showed a nonsignificant change by -12,697 US dollars (95% confidence interval [CI], 10,956 to -36,352; P = .29) with preconditioning and by -6139 US dollars (95% CI, 6723 to -19,000; P = .35) with postconditioning compared with the control group. Results were robust in our sensitivity analysis. For both procedures (control and intervention) together, major complications led to a significant increase in costs by 86,018 US dollars (95% CI, 13,839-158,198; P = .02) per patient compared with patients with no major complications. In this cost analysis, reduced in-hospital costs by pharmacologic conditioning with sevoflurane in patients undergoing liver surgery are suggested. This possible difference in costs compared with total IV anesthesia is the result of reduced complication rates with pharmacologic conditioning, because major complications have significant cost implications.
Mieczkowski, Tom
2011-03-20
This article examines the conjecture that hair analysis, performed to detect cocaine use or exposure, is biased against African Americans. It does so by comparing the outcomes of 33,928 hair and 105,792 urine samples collected from both African American and white subjects. In making this comparison the analysis seeks to determine if there is a departure in rates of positive and negative outcomes when comparing the results of hair analysis for cocaine to the results from urinalysis for cocaine by racial group. It treats urine as an unbiased test. It compares both the relative ratios of positive outcomes when comparing the two groups and it calculates the relative risk of outcomes for each group for having positive or negative outcomes. The findings show that the ratios of each racial group are effectively same for hair and urine assays, and they also show that the relative risk and risk estimates for positive and negative outcomes are the same for both racial groups. Considering all samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.28 and for urinalysis the risk estimate is 3.10 (Breslow-Day χ(2) .250, 1 df, p = 0.617) a non-significant difference in risk. For pre-employment samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.10 and for urinalysis the risk estimate is 2.90 (Breslow-Day χ(2) .281, df = 1, p = 0.595), also a non-significant difference in risk. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Comparative effect of Citrus sinensis and carbimazole on serum T4, T3 and TSH levels
Uduak, Okon Akpan; Ani, Elemi John; Etoh, Emmauel Columba Inyang; Macstephen, Adienbo Ologbagno
2014-01-01
Background: There are previous independent reports on the anti-thyroid property of Citrus sinensis. This isoflavones and phenolic acid-rich natural agent is widely consumed as dietary supplement, thus the need to investigate its comparative effect with a standard anti-thyroid drug on T4, T3 and thyroid stimulating hormone (TSH) levels. Objective: To compare the effect of Citrus sinensis and carbimazole (CARB) on blood levels of thyroid hormones (T4 and T3) and TSH. Materials and Methods: Male wistar albino rats weighing 100-150 g were employed in this research. The rats were randomly assigned to four groups of seven rats per group. Group I served as control and were administered distilled water while groups II-IV were administered with 1500 mg/kg of Citrus sinensis (fresh orange juice; FOJ), 0.1 μg/g of levothyroxine (LVT) and 0.01 mg/g of CARB, respectively, per oral once daily for 28 days. The animals were sacrificed under chloroform anaesthesia and blood sample collected by cardiac puncture and processed by standard method to obtain serum. TSH, T4 and T3 were assayed with the serum using ARIA II automated radioimmunoassay instrument. Results: The results showed that TSH level was significantly (P < 0.05) decreased in LVT treated group compared with the FOJ group. T4 was significantly (P < 0.05) decreased in the FOJ and CARB groups compared with the control and LVT groups. LVT significantly increased T4 when compared with FOJ group. T3 was significantly (P < 0.05) decreased in the CARB group compared with the control. Conclusion: These findings suggest that FOJ alters thyroid hormones metabolism to reduce their serum levels with a compensatory elevations of TSH level in a direction similar to CARB. PMID:25013255
Merlo, Gregory; Graves, Nicholas; Brain, David; Connelly, Luke B
2016-12-01
Clostridium difficile is the most common cause of hospital-acquired diarrhea in Australia. In 2013, a randomized controlled trial demonstrated the effectiveness of fecal microbiota transplantation (FMT) for the treatment of recurrent Clostridium difficile infection (CDI). The aim of this study is to evaluate the cost-effectiveness of fecal microbiota transplantation-via either nasoduodenal or colorectal delivery-compared with vancomycin for the treatment of recurrent CDI in Australia. A Markov model was developed to compare the cost-effectiveness of fecal microbiota transplantation compared with standard antibiotic therapy. A literature review of clinical evidence informed the structure of the model and the choice of parameter values. Clinical effectiveness was measured in terms of quality-adjusted life years. Uncertainty in the model was explored using probabilistic sensitivity analysis. Both nasoduodenal and colorectal FMT resulted in improved quality of life and reduced cost compared with vancomycin. The incremental effectiveness of either FMT delivery compared with vancomycin was 1.2 (95% CI: 0.1, 2.3) quality-adjusted life years, or 1.4 (95% CI: 0.4, 2.4) life years saved. Treatment with vancomycin resulted in an increased cost of AU$4094 (95% CI: AU$26, AU$8161) compared with nasoduodenal delivery of FMT and AU$4045 (95% CI: -AU$33, AU$8124) compared with colorectal delivery. The mean difference in cost between colorectal and nasoduodenal FMT was not significant. If FMT, rather than vancomycin, became standard care for recurrent CDI in Australia, the estimated national healthcare savings would be over AU$4000 per treated person, with a substantial increase in quality of life. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Wong, J B; Koff, R S
2000-11-07
Not all patients with histologically mild chronic hepatitis C progress to cirrhosis. To compare no antiviral treatment, periodic liver biopsy with subsequent antiviral treatment for moderate hepatitis or cirrhosis, and immediate antiviral therapy. Cost-effectiveness analysis. Clinical trial data and published studies. Hepatitis C virus-infected patients with histologically mild hepatitis. Lifetime. Societal. Immediate combination antiviral treatment or biopsy every 3 years plus combination antiviral therapy for moderate hepatitis or cirrhosis. Life expectancy, quality-adjusted life expectancy, and costs. Over 20 years, biopsy every 3 years with treatment of moderate hepatitis would avoid treatment in 50% of the cohort and would result in an 18% likelihood of cirrhosis compared with 16% for immediate treatment and 27% for no antiviral therapy. Immediate antiviral treatment should increase life expectancy by 1.0 quality-adjusted life-year compared with biopsy management. Over an average lifetime, biopsy management would lead to six liver biopsies costing $6200; immediate antiviral treatment would cost $5100 less than biopsy management because of savings related to biopsy and prevention of future hepatitis C-related morbidity. Immediate therapy was cost-effective compared with biopsy management and had a cost-effectiveness ratio of $7000 compared with no antiviral therapy. When age, sex, genotype, and estimates of histologic progression or compliance with follow-up are varied, immediate therapy should result in an increase of at least 0. 8 quality-adjusted life-year compared with biopsy management. For histologically mild chronic hepatitis C, initial combination treatment compared with periodic liver biopsy should reduce the future risk for cirrhosis, prolong life, and be cost-effective.
Mezgebe, Meron; Akhtar-Danesh, Gileh-Gol; Streiner, David L; Fayed, Nora; Rosenbaum, Peter L; Ronen, Gabriel M
2015-11-01
Our objective was to compare the quality of life (QoL) of children with epilepsy to that of typical children and children with cerebral palsy (CP). We measured self- and proxy-reported QoL of children with epilepsy and contrasted that with data for typical children (European KIDSCREEN project) and children with CP (SPARCLE study). Children ages 8-12 years with epilepsy were recruited from six Canadian sites. Same-aged children with CP and children in the general population aged 8-11 years came from several European countries. All participants completed the KIDSCREEN-52 questionnaire. Our results showed no clinically important differences (>0.5 SD) between self-reported QoL in 345 children with epilepsy compared with 489 children with CP or 5950 children in the general population. However, parents reported clinically important differences between the epilepsy and the other groups in five KIDSCREEN-52 domains. Compared with the CP group, parents of children with epilepsy reported better QoL in physical well-being (Cohen d=0.81), social support (d=0.80), and autonomy (d=0.72). Parents reported poorer QoL in the domains of mood and emotions compared with both contrast groups (d=-0.72 and d=-0.53), and in the domain of bullying compared with the CP group (d=-0.51). Families should find comfort in the results, which indicate that children with epilepsy do not perceive any important differences in QoL compared with their typical peers. The comparisons of parental reports detect their group-specific observations and worries that need to be addressed by the health-care providers and may require specifically designed assessment batteries followed by appropriate interventions. Copyright © 2015 Elsevier Inc. All rights reserved.
Boyd, Courtney; Crawford, Cindy; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Zhang, Weimin
2016-08-01
Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life in cancer populations. Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using the SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Twelve high quality and four low quality studies were subsequently included in the review. Results demonstrate massage therapy is effective for treating pain compared to no treatment [standardized mean difference (SMD) = -.20] and active (SMD = -0.55) comparators. Compared to active comparators, massage therapy was also found to be beneficial for treating fatigue (SMD = -1.06) and anxiety (SMD = -1.24). Based on the evidence, weak recommendations are suggested for massage therapy, compared to an active comparator, for the treatment of pain, fatigue, and anxiety. No recommendations were suggested for massage therapy compared to no treatment or sham control based on the available literature to date. This review addresses massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option for cancer pain populations. © 2016 American Academy of Pain Medicine.
Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery.
Petrovic, Stanislava; Bogavac-Stanojevic, Natasa; Lakic, Dragana; Peco-Antic, Amira; Vulicevic, Irena; Ivanisevic, Ivana; Kotur-Stevuljevic, Jelena; Jelic-Ivanovic, Zorana
2015-01-01
Acute kidney injury (AKI) is significant problem in children with congenital heart disease (CHD) who undergo cardiac surgery. The economic impact of a biomarker-based diagnostic strategy for AKI in pediatric populations undergoing CHD surgery is unknown. The aim of this study was to perform the cost effectiveness analysis of using serum cystatin C (sCysC), urine neutrophil gelatinase-associated lipocalin (uNGAL) and urine liver fatty acid-binding protein (uL-FABP) for the diagnosis of AKI in children after cardiac surgery compared with current diagnostic method (monitoring of serum creatinine (sCr) level). We developed a decision analytical model to estimate incremental cost-effectiveness of different biomarker-based diagnostic strategies compared to current diagnostic strategy. The Markov model was created to compare the lifetime cost associated with using of sCysC, uNGAL, uL-FABP with monitoring of sCr level for the diagnosis of AKI. The utility measurement included in the analysis was quality-adjusted life years (QALY). The results of the analysis are presented as the incremental cost-effectiveness ratio (ICER). Analysed biomarker-based diagnostic strategies for AKI were cost-effective compared to current diagnostic method. However, uNGAL and sCys C strategies yielded higher costs and lower effectiveness compared to uL-FABP strategy. uL-FABP added 1.43 QALY compared to current diagnostic method at an additional cost of $8521.87 per patient. Therefore, ICER for uL-FABP compared to sCr was $5959.35/QALY. Our results suggest that the use of uL-FABP would represent cost effective strategy for early diagnosis of AKI in children after cardiac surgery.
Contralateral Breast Dose After Whole-Breast Irradiation: An Analysis by Treatment Technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Terence M.; Moran, Jean M., E-mail: jmmoran@med.umich.edu; Hsu, Shu-Hui
2012-04-01
Purpose: To investigate the contralateral breast dose (CBD) across a continuum of breast-conservation therapy techniques. Methods and Materials: An anthropomorphic phantom was CT-simulated, and six treatment plans were generated: open tangents, tangents with an external wedge on the lateral beam, tangents with lateral and medial external wedges, a simple segment plan (three segments per tangent), a complex segmental intensity-modulated radiotherapy (IMRT) plan (five segments per tangent), and a beamlet IMRT plan (>100 segments). For all techniques, the breast on the phantom was irradiated to 5000 cGy. Contralateral breast dose was measured at a uniform depth at the center and eachmore » quadrant using thermoluminescent detectors. Results: Contralateral breast dose varied with position and was 50 {+-} 7.3 cGy in the inner half, 24 {+-} 4.1 cGy at the center, and 16 {+-} 2.2 cGy in the outer half for the open tangential plan. Compared with an average dose of 31 cGy across all points for the open field, the average doses were simple segment 32 cGy (range, 99-105% compared with open technique), complex segment 34 cGy (range, 103-117% compared with open technique), beamlet IMRT 34 cGy (range, 103-124% compared with open technique), lateral wedge only 46 cGy (range, 133-175% compared with open technique), and medial and lateral wedge 96 cGy (range, 282-370% compared with open technique). Conclusions: Single or dual wedge techniques resulted in the highest CBD increases compared with open tangents. To obtain the desired homogeneity to the treated breast while minimizing CBD, segmental and IMRT techniques should be encouraged over external physical compensators.« less
A comparative analysis of vaccine administration in urban and non-urban skilled nursing facilities.
Pu, Yuan; Dolar, Veronika; Gucwa, Azad L
2016-07-29
The U.S. population is aging at an unprecedented rate, resulting in an increased demand for skilled nursing facilities (SNFs) and long-term care. Residents of these facilities are at a high risk for pneumococcal disease or severe influenza-related illnesses and death. For these reasons, the Centers for Medicare and Medicaid Services use influenza and pneumococcal vaccination rates as a quality measure in the assessment of SNFs, as complications related to these infections increase morbidity and mortality rates. Disparities have been reported amongst vaccination with increased rates in urban areas as compared to their non-urban counterparts. Statistical analyses were performed to compare influenza and pneumococcal vaccination in urban and non-urban SNFs to determine variables that may influence vaccination status. Of the 15,639 nursing homes included in the study, 10,107 were in urban areas, while 5532 were considered non-urban. We found the percent of eligible and willing residents with up-to-date influenza and pneumococcal vaccinations increased with overall five-star ratings of SNFs. Somewhat paradoxically, although urban SNFs had higher mean overall five-star ratings, they showed lower rates of influenza and pneumococcal vaccination compared to non-urban SNFs. Ordinary least squares regression analysis comparing overall ratings, type of ownership, and geographic location by region yielded statistically significant results in which the overall rating, ownership-type and certificate-type favored urban SNFs (p < 0.001). This is the first systematic and comparative analysis to use the Nursing Home Compare database to assess vaccine administration of urban and non-urban SNFs. The findings of this study may be used to encourage the development of programs to improve vaccination rates and the quality of care in these facilities.
Jeyapalan, Vidhya; Krishnan, Chitra Shankar; Ramasubramanian, Hariharan; Sampathkumar, Jayakrishnakumar; Azhagarasan, N S; Krishnan, Madhusudan
2016-07-06
To comparatively evaluate the antimicrobial efficacy of freshly prepared electrolyzed oxidizing water (EOW) with that of 2.4% glutaraldehyde (GA) and 1% sodium hypochlorite (SH) on clinically derived poly vinyl siloxane (PVS) impressions. Four clinically derived PVS impressions each were obtained from 10 subjects. One impression from each subject was randomly kept as control (group I), without disinfection. The remaining three impressions were randomly disinfected by immersion in either 2.4% GA (group II), 1% SH (group III), or freshly prepared EOW (group IV). The samples were subjected to microbial culture individually on brain heart infusion (BHI) agar medium. The organisms isolated were confirmed by visual examination and gram staining. Mean colony forming units (CFU) were counted, log 10 reduction obtained and compared. Data were statistically analyzed using one-way ANOVA, followed by multiple comparisons using Tukey-HSD post hoc tests (p < 0.05). Streptococci, Staphylococci, Pseudomonas, Candida, Proteus, Klebsiella, and E. coli were isolated from all impressions including the controls, except those disinfected by EOW. All three disinfectants showed significant reduction in CFU and log 10 reduction values as compared to the controls. EOW showed significantly higher reduction in log 10 values compared to GA and SH, whereas GA and SH showed similar reductions. EOW, GA, and SH showed kill rates of 100%, 99.60%, and 99.82%, respectively. EOW showed significant antimicrobial efficacy as evidenced by reduction in log 10 values when used as an immersion disinfectant for PVS impressions when compared with the results obtained using GA and SH. These results need further investigation. EOW shows high antimicrobial efficacy when used as an immersion disinfectant as compared to GA and SH for clinically derived PVS impressions. © 2016 by the American College of Prosthodontists.
Holst, Gitte Juel; Paarup, Helene M; Baelum, Jesper
2012-08-01
To investigate psychosocial work environment and stress in Danish symphony orchestra musicians. This was a cross-sectional questionnaire survey of psychosocial work factors and stress symptoms among 441 musicians in six Danish symphony orchestras. The response rate was 78% (n = 342). The questions were from COPSOQ (Copenhagen Psychosocial Questionnaire). Mean values of 19 COPSOQ-scales were compared by gender and instrument group. The results for the musicians were compared with results for the general Danish work force (COPSOQ database). Female musicians reported higher work demands and higher stress symptoms than their male colleagues. Between instrument groups, 2nd violinists seemed to be of particular risk compared with the other instrumental groups in aspects of work pace, work organization, and content, whereas 1st violinists perceived higher emotional stress compared with 2nd violinists. The musicians' experience of increased work demands as well as deteriorated, work organization and job content, interpersonal relations and leadership, and work-individual interface was significantly associated with increasing stress symptoms. Compared to the general workforce independently of gender, Danish symphony orchestra musicians reported higher emotional demands, lower influence, lower social support, lower sense of community, and lower job satisfaction. However, the musicians reported a higher commitment to the workplace. The findings indicate a more demanding psychosocial work environment exposure among symphony orchestra musicians than among Danish workers in general. Critical results are the relatively high work demands, low influence, and low social support, females being of higher risk than males.
Wu, Peili; Zhou, Chu; Zhou, Yang; Ren, Xianlong; Chen, Xi; Zhao, Junshi; Deng, Xiaojun; Rou, Keming; Wu, Zunyou
2015-04-01
Face-to-face interview (FTFI) and polling booth survey (PBS) were applied to compare the high risk behavior among HIV-positive clients of female sex workers (CFSWs). This study was conducted in antiretroviral therapy (ART) out-patients centers in Hengyang city, where clients who had been informed on their HIV-positive status for 6 months or longer were recruited. FTFI was first used to tackle on 8 sensitive questions related to sexual behavior, followed by PBS to poke on the same questions. Results from FTFI and PBS were then compared. Compared with FIFI, results in the PBS showed higher proportion of participants who reported "having had history of sexually transmitted diseases before knowing that they were infected with HIV" (40.6% vs. 24.2%) but lower proportions on "frequency of having sex with regular sexual partner less than 4 times per month" and "using condoms consistently with regular sexual partners in past 6 months (44.4% vs. 63.0%)". There were no significant differences in the remaining 5 questions shown in the results from the two methods. HIV-positive CFSWs continued to practice unsafe sexual behaviors after knowing their HIV related status. Compared with FTFI, PBS seemed to have revealed higher proportion of unsafe sex behaviors, so as to generated more reliable data. While comparing with PBS, the traditional FTFI might have underestimated the risk behaviors among those HIV-positive CFSWs.
A Study of Comparative Advantage and Intra-Industry Trade in the Pharmaceutical Industry of Iran.
Yusefzadeh, Hassan; Rezapour, Aziz; Lotfi, Farhad; Ebadifard Azar, Farbod; Nabilo, Bahram; Abolghasem Gorji, Hassan; Hadian, Mohammad; Shahidisadeghi, Niusha; Karami, Atiyeh
2015-04-23
Drug costs in Iran accounts for about 30% of the total health care expenditure. Moreover, pharmaceutical business lies among the world's greatest businesses. The aim of this study was to analyze Iran's comparative advantage and intra-industry trade in pharmaceuticals so that suitable policies can be developed and implemented in order to boost Iran's trade in this field. To identify Iran's comparative advantage in pharmaceuticals, trade specialization, export propensity, import penetration and Balassa and Vollrath indexes were calculated and the results were compared with other pharmaceutical exporting countries. The extent and growth of Iran's intra-industry trade in pharmaceuticals were measured and evaluated using the Grubel-Lloyd and Menon-Dixon indexes. The required data was obtained from Iran's Customs Administration, Iran's pharmaceutical Statistics, World Bank and International Trade Center. The results showed that among pharmaceutical exporting countries, Iran has a high level of comparative disadvantage in pharmaceutical products because it holds a small share in world's total pharmaceutical exports. Also, the low extent of bilateral intra-industry trade between Iran and its trading partners in pharmaceuticals shows the trading model of Iran's pharmaceutical industry is mostly inter-industry trade rather than intra-industry trade. In addition, the growth of Iran's intra-industry trade in pharmaceuticals is due to its shares of imports from pharmaceutical exporting countries to Iran and exports from Iran to its neighboring countries. The results of the analysis can play a valuable role in helping pharmaceutical companies and policy makers to boost pharmaceutical trade.
Edwards, S J; Lind, T; Lundell, L
2006-09-01
No randomized controlled trial has compared all the licensed standard dose proton pump inhibitors in the healing of reflux oesophagitis. To compare the effectiveness of esomeprazole with licensed standard dose proton pump inhibitors for healing of reflux oesophagitis (i.e. lansoprazole 30 mg, omeprazole 20 mg, pantoprazole 40 mg and rabeprazole 20 mg). Systematic review of CENTRAL, BIOSIS, EMBASE and MEDLINE for randomized controlled trials in patients with reflux oesophagitis. Searching was completed in February 2005. Data on endoscopic healing rates at 4 and 8 weeks were extracted and re-analysed if not analysed by intention-to-treat. Meta-analysis was conducted using a fixed effects model. Of 133 papers identified in the literature search, six were of sufficient quality to be included in the analysis. No studies were identified comparing rabeprazole with esomeprazole. A meta-analysis of healing rates of esomeprazole 40 mg compared with standard dose proton pump inhibitors gave the following results: at 4 weeks [relative risk (RR) 0.92; 95% CI: 0.90, 0.94; P < 0.00001], and 8 weeks (RR 0.95; 95% CI: 0.94, 0.97; P < 0.00001). Publication bias did not have a significant impact on the results. The results were robust to changes in the inclusion/exclusion criteria and using a random effects model. Esomeprazole consistently demonstrates higher healing rates when compared with standard dose proton pump inhibitors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kang, S; Suh, T; Chung, J
Purpose: The purpose of this study is to evaluate the dosimetric and radiobiological impact of Acuros XB (AXB) and Anisotropic Analytic Algorithm (AAA) dose calculation algorithms on prostate stereotactic body radiation therapy plans with both conventional flattened (FF) and flattening-filter free (FFF) modes. Methods: For thirteen patients with prostate cancer, SBRT planning was performed using 10-MV photon beam with FF and FFF modes. The total dose prescribed to the PTV was 42.7 Gy in 7 fractions. All plans were initially calculated using AAA algorithm in Eclipse treatment planning system (11.0.34), and then were re-calculated using AXB with the same MUsmore » and MLC files. The four types of plans for different algorithms and beam energies were compared in terms of homogeneity and conformity. To evaluate the radiobiological impact, the tumor control probability (TCP) and normal tissue complication probability (NTCP) calculations were performed. Results: For PTV, both calculation algorithms and beam modes lead to comparable homogeneity and conformity. However, the averaged TCP values in AXB plans were always lower than in AAA plans with an average difference of 5.3% and 6.1% for 10-MV FFF and FF beam, respectively. In addition, the averaged NTCP values for organs at risk (OARs) were comparable. Conclusion: This study showed that prostate SBRT plan were comparable dosimetric results with different dose calculation algorithms as well as delivery beam modes. For biological results, even though NTCP values for both calculation algorithms and beam modes were similar, AXB plans produced slightly lower TCP compared to the AAA plans.« less
Sabale, Ugne; Ekman, Mattias; Granström, Ola; Bergenheim, Klas; McEwan, Phil
2015-02-01
The aim of this study was to assess the long-term cost-effectiveness of dapagliflozin (Forxiga(®)) added to metformin, compared with sulfonylurea (SU) added to metformin, in Nordic Type 2 diabetes mellitus (T2DM) patients inadequately controlled on metformin. Data from a 52-week clinical trial comparing dapagliflozin and SU in combination with metformin was used in a Cardiff simulation model to estimate long term diabetes-related complications in a cohort of T2DM patients. Costs and QALYs were calculated from a healthcare provider perspective and estimated over a patient's lifetime. Compared with metformin+SU, the cost per QALY gained with dapagliflozin+metformin was €7944 in Denmark, €5424 in Finland, €4769 in Norway, and €6093 in Sweden. Metformin+dapagliflozin was associated with QALY gains ranging from 0.236 in Norway to 0.278 in Sweden and incremental cost ranging from €1125 in Norway to €1962 in Denmark. Results were robust across both one-way and probabilistic sensitivity analyses. Results were driven by weight changes associated with each treatment. Results indicate that metformin+dapagliflozin is associated with gains in QALY compared with metformin+SU in Nordic T2DM patients inadequately controlled on metformin. Dapagliflozin treatment is a cost-effective treatment alternative for Type 2 diabetes in all four Nordic countries. Copyright © 2014 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.
Azoulay, Laurent; Suissa, Samy
2017-05-01
Recent randomized trials have compared the newer antidiabetic agents to treatments involving sulfonylureas, drugs associated with increased cardiovascular risks and mortality in some observational studies with conflicting results. We reviewed the methodology of these observational studies by searching MEDLINE from inception to December 2015 for all studies of the association between sulfonylureas and cardiovascular events or mortality. Each study was appraised with respect to the comparator, the outcome, and study design-related sources of bias. A meta-regression analysis was used to evaluate heterogeneity. A total of 19 studies were identified, of which six had no major design-related biases. Sulfonylureas were associated with an increased risk of cardiovascular events and mortality in five of these studies (relative risks 1.16-1.55). Overall, the 19 studies resulted in 36 relative risks as some studies assessed multiple outcomes or comparators. Of the 36 analyses, metformin was the comparator in 27 (75%) and death was the outcome in 24 (67%). The relative risk was higher by 13% when the comparator was metformin, by 20% when death was the outcome, and by 7% when the studies had design-related biases. The lowest predicted relative risk was for studies with no major bias, comparator other than metformin, and cardiovascular outcome (1.06 [95% CI 0.92-1.23]), whereas the highest was for studies with bias, metformin comparator, and mortality outcome (1.53 [95% CI 1.43-1.65]). In summary, sulfonylureas were associated with an increased risk of cardiovascular events and mortality in the majority of studies with no major design-related biases. Among studies with important biases, the association varied significantly with respect to the comparator, the outcome, and the type of bias. With the introduction of new antidiabetic drugs, the use of appropriate design and analytical tools will provide their more accurate cardiovascular safety assessment in the real-world setting. © 2017 by the American Diabetes Association.
Stidham, R W; Lee, T C H; Higgins, P D R; Deshpande, A R; Sussman, D A; Singal, A G; Elmunzer, B J; Saini, S D; Vijan, S; Waljee, A K
2014-04-01
Antibodies against tumour necrosis factor-alpha (anti-TNF) are effective therapies in the treatment of ulcerative colitis (UC), but their comparative efficacy is unknown. To perform a network meta-analysis comparing the efficacy of anti-TNF agents in UC. After screening 506 studies, reviewers extracted information on seven studies. Traditional meta-analysis (TMA) was used to compare each anti-TNF agent to placebo. Bayesian network meta-analysis (NMA) was performed to compare the effects of anti-TNF agents to placebo. In addition, sample sizes for comparative efficacy trials were calculated. Compared to placebo, TMA revealed that anti-TNF agents result in a higher likelihood of induction of remission and response (RR: 2.45, 95% CI: 1.72-3.47 and RR: 1.65, 95% CI: 1.37-1.99 respectively) as well as maintenance of remission and response (RR: 2.00, 95% CI: 1.52-2.62 and RR: 1.76, 95% CI: 1.46-2.14 respectively). Individually, infliximab, adalimumab and goliumumab resulted in a higher likelihood of induction and maintenance for both remission and response. NMA found nonsignificant trends in comparisons of the individual agents. The required sample sizes for direct head-to-head trials between infliximab and adalimumab for induction and maintenance are 174 and 204 subjects respectively. This study demonstrates that, compared to placebo, infliximab, adalimumab and golimumab are all effective for the induction and maintenance of remission in ulcerative colitis. However, network meta-analysis demonstrates that no single agent is clinically superior to the others and therefore, other factors such as cost, safety, route of administration and patient preference should dictate our choice of anti-TNF agents. A randomised comparative efficacy trial between infliximab and adalimumab in UC is of practical size and should be performed. © 2014 John Wiley & Sons Ltd.
Counterfactual Plausibility and Comparative Similarity.
Stanley, Matthew L; Stewart, Gregory W; Brigard, Felipe De
2017-05-01
Counterfactual thinking involves imagining hypothetical alternatives to reality. Philosopher David Lewis (1973, 1979) argued that people estimate the subjective plausibility that a counterfactual event might have occurred by comparing an imagined possible world in which the counterfactual statement is true against the current, actual world in which the counterfactual statement is false. Accordingly, counterfactuals considered to be true in possible worlds comparatively more similar to ours are judged as more plausible than counterfactuals deemed true in possible worlds comparatively less similar. Although Lewis did not originally develop his notion of comparative similarity to be investigated as a psychological construct, this study builds upon his idea to empirically investigate comparative similarity as a possible psychological strategy for evaluating the perceived plausibility of counterfactual events. More specifically, we evaluate judgments of comparative similarity between episodic memories and episodic counterfactual events as a factor influencing people's judgments of plausibility in counterfactual simulations, and we also compare it against other factors thought to influence judgments of counterfactual plausibility, such as ease of simulation and prior simulation. Our results suggest that the greater the perceived similarity between the original memory and the episodic counterfactual event, the greater the perceived plausibility that the counterfactual event might have occurred. While similarity between actual and counterfactual events, ease of imagining, and prior simulation of the counterfactual event were all significantly related to counterfactual plausibility, comparative similarity best captured the variance in ratings of counterfactual plausibility. Implications for existing theories on the determinants of counterfactual plausibility are discussed. Copyright © 2016 Cognitive Science Society, Inc.
NASA Astrophysics Data System (ADS)
Kim, Eng-Chan; Cho, Jae-Hwan; Kim, Min-Hye; Kim, Ki-Hong; Choi, Cheon-Woong; Seok, Jong-min; Na, Kil-Ju; Han, Man-Seok
2013-03-01
This study was conducted on 20 patients who had undergone pedicle screw fixation between March and December 2010 to quantitatively compare a conventional fat suppression technique, CHESS (chemical shift selection suppression), and a new technique, IDEAL (iterative decomposition of water and fat with echo asymmetry and least squares estimation). The general efficacy and usefulness of the IDEAL technique was also evaluated. Fat-suppressed transverse-relaxation-weighed images and longitudinal-relaxation-weighted images were obtained before and after contrast injection by using these two techniques with a 1.5T MR (magnetic resonance) scanner. The obtained images were analyzed for image distortion, susceptibility artifacts and homogenous fat removal in the target region. The results showed that the image distortion due to the susceptibility artifacts caused by implanted metal was lower in the images obtained using the IDEAL technique compared to those obtained using the CHESS technique. The results of a qualitative analysis also showed that compared to the CHESS technique, fewer susceptibility artifacts and more homogenous fat removal were found in the images obtained using the IDEAL technique in a comparative image evaluation of the axial plane images before and after contrast injection. In summary, compared to the CHESS technique, the IDEAL technique showed a lower occurrence of susceptibility artifacts caused by metal and lower image distortion. In addition, more homogenous fat removal was shown in the IDEAL technique.
Money well spent: a comparison of hospital operating margin for laparoscopic and open colectomies.
Koopmann, M C; Harms, B A; Heise, C P
2007-10-01
Cost analysis after laparoscopic colectomy has been examined, although reports evaluating the effects of laparoscopy on hospital operating margin are lacking. We compared several cost/revenue measures, including hospital operating margin, between open and laparoscopic colectomies at an academic center. Our cost-accounting database was queried for laparoscopic partial (LPC) and total colectomies (LTC), and open partial (OPC) and total colectomies (OTC) to analyze net revenue, total costs, and total hospital operating margin over a 4-year period. Laparoscopic and open colectomy cases were compared, with mean operating margin as the primary outcome. From July, 2002 through May, 2006, 842 patients were included for analysis with 138 undergoing laparoscopic colectomy. Net revenue was higher in the LTC group compared with open (US dollars 30,300 vs US dollars 26,800 [P = .02]), and lower in the LPC group (US dollars 15,300 vs US dollars 21,300 open [P < .0001]). Total costs were reduced in both the LPC and LTC groups compared with open [US dollars 11,700 vs US dollars 17,600 [P < .0001] and US dollars 18,000 vs US dollars 19,400 [P = .0019], respectively). LPC resulted in a similar HOM (US dollars 3,602) compared with OPC (US dollars 3,647; P = .35). LTC resulted in a higher HOM (US dollars 12,300) compared with OTC (US dollars 7,400; P = .02). LTC generates a significantly higher hospital operating margin than an OTC, although the margins are similar for LPC and OPC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mols, Floortje; Comprehensive Cancer Centre South; Korfage, Ida J.
Purpose: To obtain insight into the long-term (5- to 10-year) effects of prostate cancer and treatment on bowel, urinary, and sexual function, we performed a population-based study. Prostate-specific function was compared with an age-matched normative population without prostate cancer. Methods and Materials: Through the population-based Eindhoven Cancer Registry, we selected all men diagnosed with prostate cancer between 1994 and 1998 in the southern Netherlands. In total, 964 patients, alive in November 2004, received questionnaire; 780 (81%) responded. Results: Urinary problems were most common after a prostatectomy; bowel problems were most common after radiotherapy. Compared with an age-matched normative population bothmore » urinary and bowel functioning and bother were significantly worse among survivors. Urinary incontinence was reported by 23-48% of survivors compared with 4% of the normative population. Bowel leakage occurred in 5-14% of patients compared with 2% of norms. Erection problems occurred in 40-74% of patients compared with 18% of norms. Conclusions: These results form an important contribution to the limited information available on prostate-specific problems in the growing group of long-term prostate cancer survivors. Bowel, urinary, and sexual problems occur more often among long-term survivors compared with a reference group and cannot be explained merely by age. Because these problems persist for many years, urologists should provide patients with adequate information before treatment. After treatment, there should be an appropriate focus on these problems.« less
Mishra, Abhi; Kumar, Bhupesh; Dutta, Vikas; Arya, V K; Mishra, Anand Kumar
2016-06-01
To compare the effects of levosimendan with milrinone in cardiac surgical patients with pulmonary hypertension and left ventricular dysfunction. A prospective, randomized study. Tertiary care teaching hospital. The study included patients with valvular heart disease and pulmonary artery hypertension undergoing valve surgery. Forty patients were allocated randomly to receive either milrinone, 50 µg/kg bolus followed by infusion at a rate of 0.5 µg/kg/min (group 1), or levosimendan, 10 µg/kg bolus followed by infusion at a rate of 0.1 µg/kg/min (group 2) for 24 hours after surgery. Hemodynamic parameters were measured using a pulmonary artery catheter, and biventricular functions were assessed using echocardiography. Mean pulmonary artery pressures and the pulmonary vascular resistance index were comparable between the 2 groups at several time points in the intensive care unit. Biventricular function was comparable between both groups. Postcardiopulmonary bypass right ventricular systolic and diastolic functions decreased in both groups compared with baseline, whereas 6 hours postbypass left ventricular ejection fraction improved in patients with stenotic valvular lesions. Levosimendan use was associated with higher heart rate, increased cardiac index, decreased systemic vascular resistance index, and increased requirement of norepinephrine infusion compared with milrinone. The results of this study demonstrated that levosimendan was not clinically better than milrinone. Levosimendan therapy resulted in a greater increase in heart rate, decrease in systemic vascular resistance, and a greater need for norepinephrine than in patients who received milrinone. Copyright © 2016 Elsevier Inc. All rights reserved.
Change in food cravings, food preferences, and appetite during a low-carbohydrate and low-fat diet
Martin, C. K.; Rosenbaum, D.; Han, H.; Geiselman, P.; Wyatt, H.; Hill, J.; Brill, C.; Bailer, B.; Miller, B. V.; Stein, R.; Klein, S.; Foster, Gard D.
2011-01-01
The study objective was to evaluate the effect of prescribing a low-carbohydrate diet (LCD) and a low-fat diet (LFD) on food cravings, food preferences, and appetite. Obese adults were randomly assigned to a LCD (n=134) or a LFD (n=136) for two years. Cravings for specific types of foods (sweets, high-fats, fast-food fats, carbohydrates/starches); preferences for high-sugar, high-carbohydrate, and low-carbohydrate/high-protein foods; and appetite were measured during the trial and evaluated during this secondary analysis of trial data. Differences between the LCD and LFD on change in outcome variables were examined with mixed linear models. Compared to the LFD, the LCD had significantly larger decreases in cravings for carbohydrates/starches and preferences for high-carbohydrate and high-sugar foods. The LCD group reported being less bothered by hunger compared to the LFD group. Compared to the LCD group, the LFD group had significantly larger decreases in cravings for high-fat foods and preference for low-carbohydrate/high-protein foods. Men had larger decreases in appetite ratings compared to women. Prescription of diets that promoted restriction of specific types of foods resulted in decreased cravings and preferences for the foods that were targeted for restriction. The results also indicate that the LCD group was less bothered by hunger compared to the LFD group and that men had larger reductions in appetite compared to women. PMID:21494226
Analysis of stimulant drugs in the wastewater of five Nordic capitals.
Löve, Arndís Sue Ching; Baz-Lomba, Jose Antonio; Reid, Malcolm J; Kankaanpää, Aino; Gunnar, Teemu; Dam, Maria; Ólafsdóttir, Kristín; Thomas, Kevin V
2018-06-15
Wastewater-based epidemiology is an efficient way to assess illicit drug use, complementing currently used methods retrieved from different data sources. The aim of this study is to compare stimulant drug use in five Nordic capital cities that include for the first time wastewater samples from Torshavn in the Faroe Islands. Currently there are no published reports that compare stimulant drug use in these Nordic capitals. All wastewater samples were analyzed using solid phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry. The results were compared with data published by the European Monitoring Centre for Drugs and Drug Addiction based on illicit drugs in wastewater from over 50 European cities. Confirming previous reports, the results showed high amphetamine loads compared with other European countries. Very little apparent abuse of stimulant drugs was detected in Torshavn. Methamphetamine loads were the highest from Helsinki of the Nordic countries, indicating substantial fluctuations in the availability of the drug compared with previous studies. Methamphetamine loads from Oslo confirmed that the use continues to be high. Estimated cocaine use was found to be in the lower range compared with other cities in the southern and western part of Europe. Ecstasy and cocaine showed clear variations between weekdays and weekends, indicating recreational use. This study further demonstrates geographical trends in the stimulant drug market in five Nordic capitals, which enables a better comparison with other areas of the continent. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Henning, G; Henning, M; Engel, E
1989-01-01
Based on compared GDR-representative studies in 11 hospitals for gynaecology in the years 1976, 1981 and 1987 altogether 7.200 induced-terminations patients were asked about motivations and social factors of artificial abortion and used contraception. Results of interviews from 1.146 induced-termination patients younger then 20 years are given. Proceed from results propositions are leading away reduction the numbers of artificial abortions from young women.
Analysis of the Effectiveness of F-15E Risk Management during Peacetime Operations
2015-06-18
of aircraft or life . These results were compared with existing risk management programs in the form of unit worksheet assessments. This study found...Force risk management program across all fixed-wing aircraft. Rotary wing aircraft will have their own unique challenges . However, for all its...the loss of aircraft or life . These results were compared with existing risk management programs in the form of unit worksheet assessments. This
Approximate Evaluation of Reliability and Availability via Perturbation Analysis.
1986-12-01
generating the dxact answers to which the results of the approximation will be compared are discussed:." - 87 7" 2 04 2LOISTRIGUTIONIAVAILASILITYI OF...appropriately, constructing the Markov process that approximately governs interclass behavior from the result above (this is called the enlarged... compared to a numerical or analytical computation of the aame quantities. This work and its continuation represents our progress so far on Goal 3. 2.4I
Design and development aspects of flexure mechanism for high precision application
NASA Astrophysics Data System (ADS)
Sollapur, Shrishail B.; Patil, M. S.; Deshmukh, S. P.
2018-04-01
Planer XY Flexurel Mechanisms has various applications in precision motion mechanisms. A flexural mechanism generates relative motion between fixed support and motion stage using flexibility of material. This mechanism offers zero backlash, frictionless motion and high order repeatability. It is relatively compact in design as compared to rigid link mechanism. The merits of using flexure is complete mechanism can be from single monolith. Modelling of flexural mechanism to provide accurate scanning of comparatively larger range at a higher speed. Static Analysis of mechanism is carried out on FEA tool to determine static deflection of motion stage. Further Mechanism is actuated with the help of weight pan and weights. The resultant displacement is measured on Dial Gauge Indicator. Experimental set-up consists of Flexural mechanism, Dial Gauge, Weight Pan and Weights, Pulley, String, Small metal strip, Optical Bread Board etc. Further experimental Results and Analytical Results are compared and minimum deviation is found.
Marrero, Edrei Javier; Silva, Freddy Alejandro; Rosario, Inmaculada; Déniz, Soraya; Real, Fernando; Padilla, Daniel; Díaz, Esther Licia; Acosta-Hernández, Begoña
2017-10-01
Otitis caused by Malassezia pachydermatis is generally a common and recurrent disease in canine clinical pathology. The increased incidence of fungal resistant to antifungal in both humans and pets is a cause for concern and is associated with the indiscriminate use of antifungals. Finding the most effective disinfectants and antifungals has become essential. To evaluate the in vitro inhibitory activity of hydrogen peroxide on the growth of M. pachydermatis and compare its efficacy with commercial ear cleaners. The test for sensitivity to antimicrobials was carried out following the indications of the CLSI document M44-A2. The comparative results demonstrated that hydrogen peroxide 1.5% showed excellent results for growth inhibition of M. pachydermatis, followed by Epiotic ® and MalAcetic ® , the lowest result was for Otoclean ® . © 2017 Blackwell Verlag GmbH.
Blankers, M; Barendregt, M; Dekker, J J M
2016-01-01
In mental health care centres in the Netherlands outcome data are collected using a variety of outcome instruments. This may have implications for the comparability of outcome results between different centres. To discuss recent findings regarding the extent to which the eight instruments currently used in clinical practice report comparable results. Our study is based on a combination of literature review and empirical research. The results obtained with the eight instruments are not equivalent. Patients symptom reductions appear larger with some instruments than with others. The current practice of benchmarking in the Dutch mental health system would have greater validity if the number of different instruments would be reduced. State-of-the-art calibration studies are necessary to validate the comparability of the remaining instruments. Ideally, all mental health centres will soon use one instrument per care domain to measure treatment outcome.
Comparative Markedness and Induced Opacity*
Dinnsen, Daniel A.; Gierut, Judith A.; Farris-Trimble, Ashley W.
2011-01-01
Results are reported from a descriptive and experimental study that was intended to evaluate comparative markedness (McCarthy 2002, 2003) as an amendment to optimality theory. Two children (aged 4;3 and 4;11) with strikingly similar, delayed phonologies presented with two independent, interacting error patterns of special interest, i.e., Deaffrication ([tɪn] ‘chin’) and Consonant Harmony ([ɡɔɡ] ‘dog’) in a feeding interaction ([kik] ‘cheek’). Both children were enrolled in a counterbalanced treatment study employing a multiple base-line single-subject experimental design, which was intended to induce a grandfather effect in one case ([dɔɡ] ‘dog’ and [kik] ‘cheek’) and a counterfeeding interaction in the other ([ɡɔɡ] ‘dog’ and [tik] ‘cheek’). The results were largely supportive of comparative markedness, although some anomalies were observed. The clinical implications of these results are also explored. PMID:21666872
Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.
Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios
2017-01-01
To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.
LEDs as light source: examining quality of acquired images
NASA Astrophysics Data System (ADS)
Bachnak, Rafic; Funtanilla, Jeng; Hernandez, Jose
2004-05-01
Recent advances in technology have made light emitting diodes (LEDs) viable in a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. This paper presents the results of comparing images taken by a videoscope using two different light sources. One of the sources is the internal metal halide lamp and the other is a LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. The paper will present the results and discuss the usefulness and shortcomings of various comparison methods.
Survey of Experimental Results in High-Contrast Imaging for Future Exoplanet Missions
NASA Technical Reports Server (NTRS)
Lawson, P. R.; Belikov, R.; Cash, W.; Clampin, M.; Glassman, T.; Guyon, O.; Kasdin, N. J.; Kern, B. D.; Lyon, R.; Mawet, D.;
2013-01-01
We present and compare experimental results in high contrast imaging representing the state of the art in coronagraph and starshade technology. These experiments have been undertaken with the goal of demonstrating the capability of detecting Earth-like planets around nearby Sun-like stars. The contrast of an Earth seen in reflected light around a Sun-like star would be about 1.2 x 10(exp -10). Several of the current candidate technologies now yield raw contrasts of 1.0 x 10(exp -9) or better, and so should enable the detection of Earths, assuming a gain in sensitivity in post-processing of a factor of 10. We present results of coronagraph and starshade experiments conducted at visible and infrared wavelengths. Cross-sections of dark fields are directly compared as a function of field angle and bandwidth. The strength and differences of the techniques are compared.
NASA Astrophysics Data System (ADS)
Turba, Tomasz; Frącz, Paweł
2017-10-01
The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.