Sample records for comparing electronic alerts

  1. Electronic Immunization Alerts and Spillover Effects on Other Preventive Care.

    PubMed

    Kim, Julia M; Rivera, Maria; Persing, Nichole; Bundy, David G; Psoter, Kevin J; Ghazarian, Sharon R; Miller, Marlene R; Solomon, Barry S

    2017-08-01

    The impact of electronic health record (EHR) immunization clinical alert systems on the delivery of other preventive services remains unknown. We assessed for spillover effects of an EHR immunization alert on delivery of 6 other preventive services, in children 18 to 30 months of age needing immunizations. We conducted a secondary data analysis, with additional primary data collection, of a randomized, historically controlled trial to improve immunization rates with EHR alerts, in an urban, primary care clinic. No significant differences were found in screening for anemia, lead, development, nutrition, and injury prevention counseling in children prompting EHR immunization alerts (n = 129), compared with controls (n = 135). Significant increases in oral health screening in patients prompting EHR alerts (odds ratio = 4.8, 95% CI = 1.8-13.0) were likely due to practice changes over time. An EHR clinical alert system targeting immunizations did not have a spillover effect on the delivery of other preventive services.

  2. Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up?

    PubMed Central

    Dalal, Anuj K; Sahni, V Anik; Lacson, Ronilda; Khorasani, Ramin

    2016-01-01

    Objective To assess whether integrating critical result management software—Alert Notification of Critical Results (ANCR)—with an electronic health record (EHR)-based results management application impacts closed-loop communication and follow-up of nonurgent, clinically significant radiology results by primary care providers (PCPs). Materials and Methods This institutional review board-approved study was conducted at a large academic medical center. Postintervention, PCPs could acknowledge nonurgent, clinically significant ANCR-generated alerts (“alerts”) within ANCR or the EHR. Primary outcome was the proportion of alerts acknowledged via EHR over a 24-month postintervention. Chart abstractions for a random sample of alerts 12 months preintervention and 24 months postintervention were reviewed, and the follow-up rate of actionable alerts (eg, performing follow-up imaging, administering antibiotics) was estimated. Pre- and postintervention rates were compared using the Fisher exact test. Postintervention follow-up rate was compared for EHR-acknowledged alerts vs ANCR. Results Five thousand nine hundred and thirty-one alerts were acknowledged by 171 PCPs, with 100% acknowledgement (consistent with expected ANCR functionality). PCPs acknowledged 16% (688 of 4428) of postintervention alerts in the EHR, with the remaining in ANCR. Follow-up was documented for 85 of 90 (94%; 95% CI, 88%-98%) preintervention and 79 of 84 (94%; 95% CI, 87%-97%) postintervention alerts (P > .99). Postintervention, 11 of 14 (79%; 95% CI, 52%-92%) alerts were acknowledged via EHR and 68 of 70 (97%; 95% CI, 90%-99%) in ANCR had follow-up (P = .03). Conclusions Integrating ANCR and EHR provides an additional workflow for acknowledging nonurgent, clinically significant results without significant change in rates of closed-loop communication or follow-up of alerts. PMID:26335982

  3. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  4. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.

    PubMed

    Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2017-01-01

    Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N  = 148) and 51% ( N  = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N  = 5) and median 2 min ( N  = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  5. Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up?

    PubMed

    O'Connor, Stacy D; Dalal, Anuj K; Sahni, V Anik; Lacson, Ronilda; Khorasani, Ramin

    2016-03-01

    To assess whether integrating critical result management software--Alert Notification of Critical Results (ANCR)--with an electronic health record (EHR)-based results management application impacts closed-loop communication and follow-up of nonurgent, clinically significant radiology results by primary care providers (PCPs). This institutional review board-approved study was conducted at a large academic medical center. Postintervention, PCPs could acknowledge nonurgent, clinically significant ANCR-generated alerts ("alerts") within ANCR or the EHR. Primary outcome was the proportion of alerts acknowledged via EHR over a 24-month postintervention. Chart abstractions for a random sample of alerts 12 months preintervention and 24 months postintervention were reviewed, and the follow-up rate of actionable alerts (eg, performing follow-up imaging, administering antibiotics) was estimated. Pre- and postintervention rates were compared using the Fisher exact test. Postintervention follow-up rate was compared for EHR-acknowledged alerts vs ANCR. Five thousand nine hundred and thirty-one alerts were acknowledged by 171 PCPs, with 100% acknowledgement (consistent with expected ANCR functionality). PCPs acknowledged 16% (688 of 4428) of postintervention alerts in the EHR, with the remaining in ANCR. Follow-up was documented for 85 of 90 (94%; 95% CI, 88%-98%) preintervention and 79 of 84 (94%; 95% CI, 87%-97%) postintervention alerts (P > .99). Postintervention, 11 of 14 (79%; 95% CI, 52%-92%) alerts were acknowledged via EHR and 68 of 70 (97%; 95% CI, 90%-99%) in ANCR had follow-up (P = .03). Integrating ANCR and EHR provides an additional workflow for acknowledging nonurgent, clinically significant results without significant change in rates of closed-loop communication or follow-up of alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Improving Recognition of Pediatric Severe Sepsis in the Emergency Department: Contributions of a Vital Sign-Based Electronic Alert and Bedside Clinician Identification.

    PubMed

    Balamuth, Fran; Alpern, Elizabeth R; Abbadessa, Mary Kate; Hayes, Katie; Schast, Aileen; Lavelle, Jane; Fitzgerald, Julie C; Weiss, Scott L; Zorc, Joseph J

    2017-12-01

    Recognition of pediatric sepsis is a key clinical challenge. We evaluate the performance of a sepsis recognition process including an electronic sepsis alert and bedside assessment in a pediatric emergency department (ED). This was a cohort study with quality improvement intervention in a pediatric ED. Exposure was a positive electronic sepsis alert, defined as elevated pulse rate or hypotension, concern for infection, and at least one of the following: abnormal capillary refill, abnormal mental status, or high-risk condition. A positive electronic sepsis alert prompted team assessment or huddle to determine need for sepsis protocol. Clinicians could initiate team assessment or huddle according to clinical concern without positive electronic sepsis alert. Severe sepsis outcome defined as activation of the sepsis protocol in the ED or development of severe sepsis requiring ICU admission within 24 hours. There were 182,509 ED visits during the study period, with 86,037 before electronic sepsis alert implementation and 96,472 afterward, and 1,112 (1.2%) positive electronic sepsis alerts. Overall, 326 patients (0.3%) were treated for severe sepsis within 24 hours. Test characteristics of the electronic sepsis alert alone to detect severe sepsis were sensitivity 86.2% (95% confidence interval [CI] 82.0% to 89.5%), specificity 99.1% (95% CI 99.0% to 99.2%), positive predictive value 25.4% (95% CI 22.8% to 28.0%), and negative predictive value 100% (95% CI 99.9% to 100%). Inclusion of the clinician screen identified 43 additional electronic sepsis alert-negative children, with severe sepsis sensitivity 99.4% (95% CI 97.8% to 99.8%) and specificity 99.1% (95% CI 99.1% to 99.2%). Electronic sepsis alert implementation increased ED sepsis detection from 83% to 96%. Electronic sepsis alert for severe sepsis demonstrated good sensitivity and high specificity. Addition of clinician identification of electronic sepsis alert-negative patients further improved sensitivity. Implementation of the electronic sepsis alert was associated with improved recognition of severe sepsis. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  7. Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors

    PubMed Central

    Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W

    2011-01-01

    Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158

  8. Diagnostic accuracy of a screening electronic alert tool for severe sepsis and septic shock in the emergency department.

    PubMed

    Alsolamy, Sami; Al Salamah, Majid; Al Thagafi, Majed; Al-Dorzi, Hasan M; Marini, Abdellatif M; Aljerian, Nawfal; Al-Enezi, Farhan; Al-Hunaidi, Fatimah; Mahmoud, Ahmed M; Alamry, Ahmed; Arabi, Yaseen M

    2014-12-05

    Early recognition of severe sepsis and septic shock is challenging. The aim of this study was to determine the diagnostic accuracy of an electronic alert system in detecting severe sepsis or septic shock among emergency department (ED) patients. An electronic sepsis alert system was developed as a part of a quality-improvement project for severe sepsis and septic shock. The system screened all adult ED patients for a combination of systemic inflammatory response syndrome and organ dysfunction criteria (hypotension, hypoxemia or lactic acidosis). This study included all patients older than 14 years who presented to the ED of a tertiary care academic medical center from Oct. 1, 2012 to Jan. 31, 2013. As a comparator, emergency medicine physicians or the critical care physician identified the patients with severe sepsis or septic shock. In the ED, vital signs were manually entered into the hospital electronic heath record every hour in the critical care area and every two hours in other areas. We also calculated the time from the alert to the intensive care unit (ICU) referral. Of the 49,838 patients who presented to the ED, 222 (0.4%) were identified to have severe sepsis or septic shock. The electronic sepsis alert had a sensitivity of 93.18% (95% CI, 88.78% - 96.00%), specificity of 98.44 (95% CI, 98.33% - 98.55%), positive predictive value of 20.98% (95% CI, 18.50% - 23.70%) and negative predictive value of 99.97% (95% CI, 99.95% - 99.98%) for severe sepsis and septic shock. The alert preceded ICU referral by a median of 4.02 hours (Q1 - Q3: 1.25-8.55). Our study shows that electronic sepsis alert tool has high sensitivity and specificity in recognizing severe sepsis and septic shock, which may improve early recognition and management.

  9. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  10. High-priority and low-priority drug-drug interactions in different international electronic health record systems: A comparative study.

    PubMed

    Cornu, Pieter; Phansalkar, Shobha; Seger, Diane L; Cho, Insook; Pontefract, Sarah; Robertson, Alexandra; Bates, David W; Slight, Sarah P

    2018-03-01

    To investigate whether alert warnings for high-priority and low-priority drug-drug interactions (DDIs) were present in five international electronic health record (EHR) systems, to compare and contrast the severity level assigned to them, and to establish the proportion of alerts that were overridden. We conducted a comparative, retrospective, multinational study using a convenience sample of 5 EHRs from the U.S., U.K., Republic of Korea and Belgium. Of the 15 previously defined, high-priority, class-based DDIs, alert warnings were found to exist for 11 in both the Korean and UK systems, 9 in the Belgian system, and all 15 in the two US systems. The specific combinations that were included in these class-based DDIs varied considerably in number, type and level of severity amongst systems. Alerts were only active for 8.4% (52/619) and 52.4% (111/212) of the specific drug-drug combinations contained in the Belgian and UK systems, respectively. Hard stops (not possible to override) existed in the US and UK systems only. The override rates for high-priority alerts requiring provider action ranged from 56.7% to 83.3%. Of the 33 previously defined low-priority DDIs, active alerts existed only in the US systems, for three class-based DDIs. The majority were non-interruptive. Alert warnings existed for most of the high-priority DDIs in the different EHRs but overriding them was easy in most of the systems. In addition to validating the high- and low-priority DDIs, this study reported a lack of standardization in DDI levels across different international knowledge bases. Copyright © 2017. Published by Elsevier B.V.

  11. Evaluation of medication alerts in electronic health records for compliance with human factors principles

    PubMed Central

    Phansalkar, Shobha; Zachariah, Marianne; Seidling, Hanna M; Mendes, Chantal; Volk, Lynn; Bates, David W

    2014-01-01

    Introduction Increasing the adoption of electronic health records (EHRs) with integrated clinical decision support (CDS) is a key initiative of the current US healthcare administration. High over-ride rates of CDS alerts strongly limit these potential benefits. As a result, EHR designers aspire to improve alert design to achieve better acceptance rates. In this study, we evaluated drug–drug interaction (DDI) alerts generated in EHRs and compared them for compliance with human factors principles. Methods We utilized a previously validated questionnaire, the I-MeDeSA, to assess compliance with nine human factors principles of DDI alerts generated in 14 EHRs. Two reviewers independently assigned scores evaluating the human factors characteristics of each EHR. Rankings were assigned based on these scores and recommendations for appropriate alert design were derived. Results The 14 EHRs evaluated in this study received scores ranging from 8 to 18.33, with a maximum possible score of 26. Cohen's κ (κ=0.86) reflected excellent agreement among reviewers. The six vendor products tied for second and third place rankings, while the top system and bottom five systems were home-grown products. The most common weaknesses included the absence of characteristics such as alert prioritization, clear and concise alert messages indicating interacting drugs, actions for clinical management, and a statement indicating the consequences of over-riding the alert. Conclusions We provided detailed analyses of the human factors principles which were assessed and described our recommendations for effective alert design. Future studies should assess whether adherence to these recommendations can improve alert acceptance. PMID:24780721

  12. Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients

    PubMed Central

    Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.

    2008-01-01

    Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982

  13. A randomized trial of automated electronic alerts demonstrating improved reimbursable anesthesia time documentation.

    PubMed

    Freundlich, Robert E; Barnet, Caryn S; Mathis, Michael R; Shanks, Amy M; Tremper, Kevin K; Kheterpal, Sachin

    2013-03-01

    To investigate whether alerting providers to errors results in improved documentation of reimbursable anesthesia care. Prospective randomized controlled trial. Operating room (OR) of a university hospital. Anesthesia cases were evaluated to determine whether they met the definition for appropriate anesthesia start time over 4 separate, 45-day calendar cycles: the pre-study period, study period, immediate post-study period, and 3-year follow-up period. During the study period, providers were randomly assigned to either a control or an alert group. Providers in the alert cohort received an automated alphanumeric page if the anesthesia start time occurred concurrently with the patient entering the OR, or more than 30 minutes before entering the OR. Three years after the intervention period, overall compliance was analyzed to assess learned behavior. Baseline compliance was 33% ± 5%. During the intervention period, providers in the alert group showed 87% ± 6% compliance compared with 41% ± 7% compliance in the control group (P < 0.001). Long-term follow-up after cessation of the alerts showed 85% ± 4% compliance. Automated electronic reminders for time-based billing charges are effective and result in improved ongoing reimbursement. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department

    PubMed Central

    Balamuth, Fran; Alpern, Elizabeth R.; Grundmeier, Robert W.; Chilutti, Marianne; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-01-01

    Objectives To compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). Methods This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Results Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159, and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% CI = 72.1% to 73.4%) and specificity 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity 92.1% (95% CI = 91.7% to 92.4%), and specificity 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment vs. algorithmic alert were 40.3% vs. 2.5% and 99.88 % vs. 99.96%, respectively. Conclusions The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. PMID:26474032

  15. Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department.

    PubMed

    Balamuth, Fran; Alpern, Elizabeth R; Grundmeier, Robert W; Chilutti, Marianne; Weiss, Scott L; Fitzgerald, Julie C; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing

    2015-11-01

    The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively. The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. © 2015 by the Society for Academic Emergency Medicine.

  16. Impact of real-time electronic alerting of acute kidney injury on therapeutic intervention and progression of RIFLE class.

    PubMed

    Colpaert, Kirsten; Hoste, Eric A; Steurbaut, Kristof; Benoit, Dominique; Van Hoecke, Sofie; De Turck, Filip; Decruyenaere, Johan

    2012-04-01

    To evaluate whether a real-time electronic alert system or "AKI sniffer," which is based on the RIFLE classification criteria (Risk, Injury and Failure), would have an impact on therapeutic interventions and acute kidney injury progression. Prospective intervention study. Surgical and medical intensive care unit in a tertiary care hospital. A total of 951 patients having in total 1,079 admission episodes were admitted during the study period (prealert control group: 227, alert group: 616, and postalert control group: 236). Three study phases were compared: A 1.5-month prealert control phase in which physicians were blinded for the acute kidney injury sniffer and a 3-month intervention phase with real-time alerting of worsening RIFLE class through the Digital Enhanced Cordless Technology telephone system followed by a second 1.5-month postalert control phase. A total of 2593 acute kidney injury alerts were recorded with a balanced distribution over all study phases. Most acute kidney injury alerts were RIFLE class risk (59.8%) followed by RIFLE class injury (34.1%) and failure (6.1%). A higher percentage of patients in the alert group received therapeutic intervention within 60 mins after the acute kidney injury alert (28.7% in alert group vs. 7.9% and 10.4% in the pre- and postalert control groups, respectively, p μ .001). In the alert group, more patients received fluid therapy (23.0% vs. 4.9% and 9.2%, p μ .01), diuretics (4.2% vs. 2.6% and 0.8%, p μ .001), or vasopressors (3.9% vs. 1.1% and 0.8%, p μ .001). Furthermore, these patients had a shorter time to intervention (p μ .001). A higher proportion of patients in the alert group showed return to a baseline kidney function within 8 hrs after an acute kidney injury alert "from normal to risk" compared with patients in the control group (p = .048). The real-time alerting of every worsening RIFLE class by the acute kidney injury sniffer increased the number and timeliness of early therapeutic interventions. The borderline significant improvement of short-term renal outcome in the RIFLE class risk patients needs to be confirmed in a large multicenter trial.

  17. Acute Kidney Injury in the Era of the AKI E-Alert

    PubMed Central

    Holmes, Jennifer; Rainer, Timothy; Geen, John; Roberts, Gethin; May, Kate; Wilson, Nick; Williams, John D.

    2016-01-01

    Background and objectives Our aim was to use a national electronic AKI alert to define the incidence and outcome of all episodes of community– and hospital–acquired adult AKI. Design, setting, participants, & measurements A prospective national cohort study was undertaken in a population of 3.06 million. Data were collected between March of 2015 and August of 2015. All patients with adult (≥18 years of age) AKI were identified to define the incidence and outcome of all episodes of community- and hospital-acquired AKI in adults. Mortality and renal outcomes were assessed at 90 days. Results There was a total of 31,601 alerts representing 17,689 incident episodes, giving an incidence of AKI of 577 per 100,000 population. Community-acquired AKI accounted for 49.3% of all incident episodes, and 42% occurred in the context of preexisting CKD (Chronic Kidney Disease Epidemiology Collaboration eGFR); 90-day mortality rate was 25.6%, and 23.7% of episodes progressed to a higher AKI stage than the stage associated with the alert. AKI electronic alert stage and peak AKI stage were associated with mortality, and mortality was significantly higher for hospital-acquired AKI compared with alerts generated in a community setting. Among patients who survived to 90 days after the AKI electronic alert, those who were not hospitalized had a lower rate of renal recovery and a greater likelihood of developing an eGFR<60 ml/min per 1.73 m2 for the first time, which may be indicative of development of de novo CKD. Conclusions The reported incidence of AKI is far greater than the previously reported incidence in studies reliant on clinical identification of adult AKI or hospital coding data. Although an electronic alert system is Information Technology driven and therefore, lacks intelligence and clinical context, these data can be used to identify deficiencies in care, guide the development of appropriate intervention strategies, and provide a baseline against which the effectiveness of these interventions may be measured. PMID:27793961

  18. Using electronic health record alerts to provide public health situational awareness to clinicians.

    PubMed

    Lurio, Joseph; Morrison, Frances P; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations.

  19. Using electronic health record alerts to provide public health situational awareness to clinicians

    PubMed Central

    Lurio, Joseph; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations. PMID:20190067

  20. The Nature and Variability of Automated Practice Alerts Derived from Electronic Health Records in a U.S. Nationwide Critical Care Research Network.

    PubMed

    Benthin, Cody; Pannu, Sonal; Khan, Akram; Gong, Michelle

    2016-10-01

    The nature, variability, and extent of early warning clinical practice alerts derived from automated query of electronic health records (e-alerts) currently used in acute care settings for clinical care or research is unknown. To describe e-alerts in current use in acute care settings at medical centers participating in a nationwide critical care research network. We surveyed investigators at 38 institutions involved in the National Institutes of Health-funded Clinical Trials Network for the Prevention and Early Treatment of Acute Lung Injury (PETAL) for quantitative and qualitative analysis. Thirty sites completed the survey (79% response rate). All sites used electronic health record systems. Epic Systems was used at 56% of sites; the others used alternate commercially available vendors or homegrown systems. Respondents at 57% of sites represented in this survey used e-alerts. All but 1 of these 17 sites used an e-alert for early detection of sepsis-related syndromes, and 35% used an e-alert for pneumonia. E-alerts were triggered by abnormal laboratory values (37%), vital signs (37%), or radiology reports (15%) and were used about equally for clinical decision support and research. Only 59% of sites with e-alerts have evaluated them either for accuracy or for validity. A majority of the research network sites participating in this survey use e-alerts for early notification of potential threats to hospitalized patients; however, there was significant variability in the nature of e-alerts between institutions. Use of one common electronic health record vendor at more than half of the participating sites suggests that it may be possible to standardize e-alerts across multiple sites in research networks, particularly among sites using the same medical record platform.

  1. Effect of an obesity best practice alert on physician documentation and referral practices.

    PubMed

    Fitzpatrick, Stephanie L; Dickins, Kirsten; Avery, Elizabeth; Ventrelle, Jennifer; Shultz, Aaron; Kishen, Ekta; Rothschild, Steven

    2017-12-01

    The Centers for Medicare & Medicaid Services Electronic Health Record Meaningful Use Incentive Program requires physicians to document body mass index (BMI) and a follow-up treatment plan for adult patients with BMI ≥ 25. To examine the effect of a best practice alert on physician documentation of obesity-related care and referrals to weight management treatment, in a cluster-randomized design, 14 primary care clinics at an academic medical center were randomized to best practice alert intervention (n = 7) or comparator (n = 7). The alert was triggered when both height and weight were entered and BMI was ≥30. Both intervention and comparator clinics could document meaningful use by selecting a nutrition education handout within the alert. Intervention clinics could also select a referral option from the list of clinic and community-based weight management programs embedded in the alert. Main outcomes were proportion of eligible patients with (1) obesity-related documentation and (2) referral. There were 26,471 total primary care encounters with 12,981 unique adult patients with BMI ≥ 30 during the 6-month study period. Documentation doubled (17 to 33%) with implementation of the alert. However, intervention clinics were not significantly more likely to refer patients to weight management than comparator clinics (2.8 vs. 1.3%, p = 0.07). Although the alert was associated with increased physician meaningful use compliance, it was not an effective strategy for improving patient access to weight management services. Further research is needed to understand system-level characteristics that influence obesity management in primary care.

  2. Comparison of Overridden Medication-related Clinical Decision Support in the Intensive Care Unit between a Commercial System and a Legacy System.

    PubMed

    Wong, Adrian; Wright, Adam; Seger, Diane L; Amato, Mary G; Fiskio, Julie M; Bates, David

    2017-08-23

    Electronic health records (EHRs) with clinical decision support (CDS) have shown to be effective at improving patient safety. Despite this, alerts delivered as part of CDS are overridden frequently, which is of concern in the critical care population as this group may have an increased risk of harm. Our organization recently transitioned from an internally-developed EHR to a commercial system. Data comparing various EHR systems, especially after transitions between EHRs, are needed to identify areas for improvement. To compare the two systems and identify areas for potential improvement with the new commercial system at a single institution. Overridden medication-related CDS alerts were included from October to December of the systems' respective years (legacy, 2011; commercial, 2015), restricted to three intensive care units. The two systems were compared with regards to CDS presentation and override rates for four types of CDS: drug-allergy, drug-drug interaction (DDI), geriatric and renal alerts. A post hoc analysis to evaluate for adverse drug events (ADEs) potentially resulting from overridden alerts was performed for 'contraindicated' DDIs via chart review. There was a significant increase in provider exposure to alerts and alert overrides in the commercial system (commercial: n=5,535; legacy: n=1,030). Rates of overrides were higher for the allergy and DDI alerts (p<0.001) in the commercial system. Geriatric and renal alerts were significantly different in incidence and presentation between the two systems. No ADEs were identified in an analysis of 43 overridden contraindicated DDI alerts. The vendor system had much higher rates of both alerts and overrides, although we did not find evidence of harm in a review of DDIs which were overridden. We propose recommendations for improving our current system which may be helpful to other similar institutions; improving both alert presentation and the underlying knowledge base appear important.

  3. Potential drug related problems detected by electronic expert support system in patients with multi-dose drug dispensing.

    PubMed

    Tora, Hammar; Bo, Hovstadius; Bodil, Lidström; Göran, Petersson; Birgit, Eiermann

    2014-10-01

    Background Drug related problems (DRPs) are frequent and cause suffering for patients and substantial costs for society. Multi-dose drug dispensing (MDDD) is a service by which patients receive their medication packed in bags with one unit for each dose occasion. The clinical decision support system (CDSS) electronic expert support (EES) analyses patients' prescriptions in the Swedish national e-prescription repository and provides alerts if potential DRPs are detected, i.e. drug-drug interactions, duplicate therapy, drug-disease contraindications, high dose, gender warnings, geriatric, and paediatric alerts. Objective To analyse potential DRPs in patients with MDDD, detected by means of EES. Setting A register study of all electronically stored prescriptions for patients with MDDD in Sweden (n = 180,059) March 5-June 5, 2013. Method Drug use and potential DRPs detected in the study population during the 3 month study period by EES were analysed. The potential DRPs were analysed in relation to patients' age, gender, number of drugs, and type of medication. Main outcome measure Prevalence of potential DRPs measured as EES alerts. Results The study population was on average 75.8 years of age (± 17.5, range 1-110) and had 10.0 different medications (± 4.7, range 1-53). EES alerted for potential DRPs in 76 % of the population with a mean of 2.2 alerts per patient (± 2.4, range 0-27). The older patients received a lower number of alerts compared to younger patients despite having a higher number of drugs. The most frequent alert categories were drug-drug interactions (37 % of all alerts), duplicate therapy (30 %), and geriatric warnings for high dose or inappropriate drugs (23 %). Psycholeptics, psychoanaleptics, antithrombotic agents, anti-epileptics, renin-angiotensin system agents, and analgesics represented 71 % of all drugs involved in alerts. Conclusions EES detected potential DRPs in the majority of patients with MDDD. The number of potential DRPs was associated with the number of drugs, age, gender, and type of medication. A CDSS such as EES might be a useful tool for physicians and pharmacists to assist in the important task of monitoring patients with MDDD for potential DRPs.

  4. Development of an "Alert Framework" Based on the Practices in the Medical Front.

    PubMed

    Sakata, Takuya; Araki, Kenji; Yamazaki, Tomoyoshi; Kawano, Koichi; Maeda, Minoru; Kushima, Muneo; Araki, Sanae

    2018-05-09

    At the University of Miyazaki Hospital (UMH), we have accumulated and semantically structured a vast amount of medical information since the activation of the electronic health record system approximately 10 years ago. With this medical information, we have decided to develop an alert system for aiding in medical treatment. The purpose of this investigation is to not only to integrate an alert framework into the electronic heath record system, but also to formulate a modeling method of this knowledge. A trial alert framework was developed for the staff in various occupational categories at the UMH. Based on findings of subsequent interviews, a more detailed and upgraded alert framework was constructed, resulting in the final model. Based on our current findings, an alert framework was developed with four major items. Based on the analysis of the medical practices from the trial model, it has been concluded that there are four major risk patterns that trigger the alert. Furthermore, the current alert framework contains detailed definitions which are easily substituted into the database, leading to easy implementation of the electronic health records.

  5. Association of a Best-Practice Alert and Prenatal Administration With Tetanus Toxoid, Reduced Diphtheria Toxoid, and Acellular Pertussis Vaccination Rates.

    PubMed

    Morgan, Jamie L; Baggari, Sangameshwar R; Chung, Wendy; Ritch, Julia; McIntire, Donald D; Sheffield, Jeanne S

    2015-08-01

    To evaluate how implementation of a best-practice alert, a reminder of clinical guidelines within the electronic medical record, in combination with the recommended change in immunization timing from postpartum to antepartum, affected tetanus toxoid, reduced diphtheria toxoid and acellular pertussis (Tdap) rates, and to examine the association of vaccination with local pertussis attack rates. A Tdap best-practice alert was introduced into the electronic prenatal charting system in June 2013. The best-practice alert was designed to appear starting at 32 weeks of gestation and to reappear at every subsequent encounter until vaccine acceptance was recorded or delivery occurred. The overall acceptance rate was then compared with postpartum vaccination rates at our institution from the previous year. Records of pertussis cases in children younger than 2 years of age diagnosed since 2012 in Dallas County were also reviewed to correlate local trends with vaccination efforts. Of the 10,201 women offered Tdap during prenatal care, 9,879 (96.8%) ultimately accepted. This is compared with a 48% (5,064 of 10,600) Tdap postpartum immunization rate in the year prior, before introduction of the best-practice alert. The incidence of pertussis among neonates born to mothers who received prenatal care at Parkland Hospital showed a nonsignificant decline from 13 cases per 10,000 deliveries (19 of 14,834, 95% confidence interval [CI] 7-19) between January 2012 and May 2013 to seven per 10,000 deliveries during the study period (eight of 11,788, 95% CI 2-11, P=.174). The use of a best-practice alert, in concert with the recommended change in timing of maternal vaccination from postpartum to antepartum, was associated with an increase in the Tdap immunization rate to 97%. II.

  6. Feedback mechanisms including real-time electronic alerts to achieve near 100% timely prophylactic antibiotic administration in surgical cases.

    PubMed

    Nair, Bala G; Newman, Shu-Fang; Peterson, Gene N; Wu, Wei-Ying; Schwid, Howard A

    2010-11-01

    Administration of prophylactic antibiotics during surgery is generally performed by the anesthesia providers. Timely antibiotic administration within the optimal time window before incision is critical for prevention of surgical site infections. However, this often becomes a difficult task for the anesthesia team during the busy part of a case when the patient is being anesthetized. Starting with the implementation of an anesthesia information management system (AIMS), we designed and implemented several feedback mechanisms to improve compliance of proper antibiotic delivery and documentation. This included generating e-mail feedback of missed documentation, distributing monthly summary reports, and generating real-time electronic alerts with a decision support system. In 20,974 surgical cases for the period, June 2008 to January 2010, the interventions of AIMS install, e-mail feedback, summary reports, and real-time alerts changed antibiotic compliance by -1.5%, 2.3%, 4.9%, and 9.3%, respectively, when compared with the baseline value of 90.0% ± 2.9% when paper anesthesia records were used. Highest antibiotic compliance was achieved when using real-time alerts. With real-time alerts, monthly compliance was >99% for every month between June 2009 and January 2010. Installation of AIMS itself did not improve antibiotic compliance over that achieved with paper anesthesia records. However, real-time guidance and reminders through electronic messages generated by a computerized decision support system (Smart Anesthesia Messenger, or SAM) significantly improved compliance. With such a system a consistent compliance of >99% was achieved.

  7. Provider management strategies of abnormal test result alerts: a cognitive task analysis.

    PubMed

    Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.

  8. Identification of Patients Expected to Benefit from Electronic Alerts for Acute Kidney Injury.

    PubMed

    Biswas, Aditya; Parikh, Chirag R; Feldman, Harold I; Garg, Amit X; Latham, Stephen; Lin, Haiqun; Palevsky, Paul M; Ugwuowo, Ugochukwu; Wilson, F Perry

    2018-06-07

    Electronic alerts for heterogenous conditions such as AKI may not provide benefit for all eligible patients and can lead to alert fatigue, suggesting that personalized alert targeting may be useful. Uplift-based alert targeting may be superior to purely prognostic-targeting of interventions because uplift models assess marginal treatment effect rather than likelihood of outcome. This is a secondary analysis of a clinical trial of 2278 adult patients with AKI randomized to an automated, electronic alert system versus usual care. We used three uplift algorithms and one purely prognostic algorithm, trained in 70% of the data, and evaluated the effect of targeting alerts to patients with higher scores in the held-out 30% of the data. The performance of the targeting strategy was assessed as the interaction between the model prediction of likelihood to benefit from alerts and randomization status. The outcome of interest was maximum relative change in creatinine from the time of randomization to 3 days after randomization. The three uplift score algorithms all gave rise to a significant interaction term, suggesting that a strategy of targeting individuals with higher uplift scores would lead to a beneficial effect of AKI alerting, in contrast to the null effect seen in the overall study. The prognostic model did not successfully stratify patients with regards to benefit of the intervention. Among individuals in the high uplift group, alerting was associated with a median reduction in change in creatinine of -5.3% ( P =0.03). In the low uplift group, alerting was associated with a median increase in change in creatinine of +5.3% ( P =0.005). Older individuals, women, and those with a lower randomization creatinine were more likely to receive high uplift scores, suggesting that alerts may benefit those with more slowly developing AKI. Uplift modeling, which accounts for treatment effect, can successfully target electronic alerts for AKI to those most likely to benefit, whereas purely prognostic targeting cannot. Copyright © 2018 by the American Society of Nephrology.

  9. Provider management strategies of abnormal test result alerts: a cognitive task analysis

    PubMed Central

    Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805

  10. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    PubMed

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  11. Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard.

    PubMed

    Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D

    2015-03-01

    To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Use of a novel electronic maternal surveillance system to generate automated alerts on the labor and delivery unit.

    PubMed

    Klumpner, Thomas T; Kountanis, Joanna A; Langen, Elizabeth S; Smith, Roger D; Tremper, Kevin K

    2018-06-26

    Maternal early warning systems reduce maternal morbidity. We developed an electronic maternal surveillance system capable of visually summarizing the labor and delivery census and identifying changes in clinical status. Automatic page alerts to clinical providers, using an algorithm developed at our institution, were incorporated in an effort to improve early detection of maternal morbidity. We report the frequency of pages generated by the system. To our knowledge, this is the first time such a system has been used in peripartum care. Alert criteria were developed after review of maternal early warning systems, including the Maternal Early Warning Criteria (MEWC). Careful consideration was given to the frequency of pages generated by the surveillance system. MEWC notification criteria were liberalized and a paging algorithm was created that triggered paging alerts to first responders (nurses) and then managing services due to the assumption that paging all clinicians for each vital sign triggering MEWC would generate an inordinate number of pages. For preliminary analysis, to determine the effect of our automated paging algorithm on alerting frequency, the paging frequency of this system was compared to the frequency of vital signs meeting the Maternal Early Warning Criteria (MEWC). This retrospective analysis was limited to a sample of 34 patient rooms uniquely capable of storing every vital sign reported by the bedside monitor. Over a 91-day period, from April 1 to July 1, 2017, surveillance was conducted from 64 monitored beds, and the obstetrics service received one automated page every 2.3 h. The most common triggers for alerts were for hypertension and tachycardia. For the subset of 34 patient rooms uniquely capable of real-time recording, one vital sign met the MEWC every 9.6 to 10.3 min. Anecdotally, the system was well-received. This novel electronic maternal surveillance system is designed to reduce cognitive bias and improve timely clinical recognition of maternal deterioration. The automated paging algorithm developed for this software dramatically reduces paging frequency compared to paging for isolated vital sign abnormalities alone. Long-term, prospective studies will be required to determine its impact on patient outcomes.

  13. Reduction in alert fatigue in an assisted electronic prescribing system, through the Lean Six Sigma methodology.

    PubMed

    Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis

    2017-01-01

    To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  14. Applications for detection of acute kidney injury using electronic medical records and clinical information systems: workgroup statements from the 15(th) ADQI Consensus Conference.

    PubMed

    James, Matthew T; Hobson, Charles E; Darmon, Michael; Mohan, Sumit; Hudson, Darren; Goldstein, Stuart L; Ronco, Claudio; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Electronic medical records and clinical information systems are increasingly used in hospitals and can be leveraged to improve recognition and care for acute kidney injury. This Acute Dialysis Quality Initiative (ADQI) workgroup was convened to develop consensus around principles for the design of automated AKI detection systems to produce real-time AKI alerts using electronic systems. AKI alerts were recognized by the workgroup as an opportunity to prompt earlier clinical evaluation, further testing and ultimately intervention, rather than as a diagnostic label. Workgroup members agreed with designing AKI alert systems to align with the existing KDIGO classification system, but recommended future work to further refine the appropriateness of AKI alerts and to link these alerts to actionable recommendations for AKI care. The consensus statements developed in this review can be used as a roadmap for development of future electronic applications for automated detection and reporting of AKI.

  15. Real-time Automated Sampling of Electronic Medical Records Predicts Hospital Mortality

    PubMed Central

    Khurana, Hargobind S.; Groves, Robert H.; Simons, Michael P.; Martin, Mary; Stoffer, Brenda; Kou, Sherri; Gerkin, Richard; Reiman, Eric; Parthasarathy, Sairam

    2016-01-01

    Background Real-time automated continuous sampling of electronic medical record data may expeditiously identify patients at risk for death and enable prompt life-saving interventions. We hypothesized that a real-time electronic medical record-based alert could identify hospitalized patients at risk for mortality. Methods An automated alert was developed and implemented to continuously sample electronic medical record data and trigger when at least two of four systemic inflammatory response syndrome criteria plus at least one of 14 acute organ dysfunction parameters was detected. The SIRS/OD alert was applied real-time to 312,214 patients in 24 hospitals and analyzed in two phases: training and validation datasets. Results In the training phase, 29,317 (18.8%) triggered the alert and 5.2% of such patients died whereas only 0.2% without the alert died (unadjusted odds ratio 30.1; 95% confidence interval [95%CI] 26.1, 34.5; P<0.0001). In the validation phase, the sensitivity, specificity, area under curve (AUC), positive and negative likelihood ratios for predicting mortality were 0.86, 0.82, 0.84, 4.9, and 0.16, respectively. Multivariate Cox-proportional hazard regression model revealed greater hospital mortality when the alert was triggered (adjusted Hazards Ratio 4.0; 95%CI 3.3, 4.9; P<0.0001). Triggering the alert was associated with additional hospitalization days (+3.0 days) and ventilator days (+1.6 days; P<0.0001). Conclusion An automated alert system that continuously samples electronic medical record-data can be implemented, has excellent test characteristics, and can assist in the real-time identification of hospitalized patients at risk for death. PMID:27019043

  16. Conditional Outlier Detection for Clinical Alerting

    PubMed Central

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F.

    2010-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates. PMID:21346986

  17. Conditional outlier detection for clinical alerting.

    PubMed

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F

    2010-11-13

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates.

  18. High incidence of venous thromboembolism despite electronic alerts for thromboprophylaxis in hospitalised cancer patients.

    PubMed

    Lecumberri, Ramón; Marqués, Margarita; Panizo, Elena; Alfonso, Ana; García-Mouriz, Alberto; Gil-Bazo, Ignacio; Hermida, José; Schulman, Sam; Páramo, José A

    2013-07-01

    Many cancer patients are at high risk of venous thromboembolism (VTE) during hospitalisation; nevertheless, thromboprophylaxis is frequently underused. Electronic alerts (e-alerts) have been associated with improvement in thromboprophylaxis use and a reduction of the incidence of VTE, both during hospitalisation and after discharge, particularly in the medical setting. However, there are no data regarding the benefit of this tool in cancer patients. Our aim was to evaluate the impact of a computer-alert system for VTE prevention in patients with cancer, particularly in those admitted to the Oncology/Haematology ward, comparing the results with the rest of inpatients at a university teaching hospital. The study included 32,167 adult patients hospitalised during the first semesters of years 2006 to 2010, 9,265 (28.8%) with an active malignancy. Appropriate prophylaxis in medical patients, significantly increased over time (from 40% in 2006 to 57% in 2010) and was maintained over 80% in surgical patients. However, while e-alerts were associated with a reduction of the incidence of VTE during hospitalisation in patients without cancer (odds ratio [OR] 0.31; 95% confidence interval [CI], 0.15-0.64), the impact was modest in cancer patients (OR 0.89; 95% CI, 0.42-1.86) and no benefit was observed in patients admitted to the Oncology/Haematology Departments (OR 1.11; 95% CI, 0.45-2.73). Interestingly, 60% of VTE episodes in cancer patients during recent years developed despite appropriate prophylaxis. Contrary to the impact on hospitalised patients without cancer, implementation of e-alerts for VTE risk did not prevent VTE effectively among those with malignancies.

  19. Prescription errors before and after introduction of electronic medication alert system in a pediatric emergency department.

    PubMed

    Sethuraman, Usha; Kannikeswaran, Nirupama; Murray, Kyle P; Zidan, Marwan A; Chamberlain, James M

    2015-06-01

    Prescription errors occur frequently in pediatric emergency departments (PEDs).The effect of computerized physician order entry (CPOE) with electronic medication alert system (EMAS) on these is unknown. The objective was to compare prescription errors rates before and after introduction of CPOE with EMAS in a PED. The hypothesis was that CPOE with EMAS would significantly reduce the rate and severity of prescription errors in the PED. A prospective comparison of a sample of outpatient, medication prescriptions 5 months before and after CPOE with EMAS implementation (7,268 before and 7,292 after) was performed. Error types and rates, alert types and significance, and physician response were noted. Medication errors were deemed significant if there was a potential to cause life-threatening injury, failure of therapy, or an adverse drug effect. There was a significant reduction in the errors per 100 prescriptions (10.4 before vs. 7.3 after; absolute risk reduction = 3.1, 95% confidence interval [CI] = 2.2 to 4.0). Drug dosing error rates decreased from 8 to 5.4 per 100 (absolute risk reduction = 2.6, 95% CI = 1.8 to 3.4). Alerts were generated for 29.6% of prescriptions, with 45% involving drug dose range checking. The sensitivity of CPOE with EMAS in identifying errors in prescriptions was 45.1% (95% CI = 40.8% to 49.6%), and the specificity was 57% (95% CI = 55.6% to 58.5%). Prescribers modified 20% of the dosing alerts, resulting in the error not reaching the patient. Conversely, 11% of true dosing alerts for medication errors were overridden by the prescribers: 88 (11.3%) resulted in medication errors, and 684 (88.6%) were false-positive alerts. A CPOE with EMAS was associated with a decrease in overall prescription errors in our PED. Further system refinements are required to reduce the high false-positive alert rates. © 2015 by the Society for Academic Emergency Medicine.

  20. Increased appropriateness of customized alert acknowledgement reasons for overridden medication alerts in a computerized provider order entry system.

    PubMed

    Dekarske, Brian M; Zimmerman, Christopher R; Chang, Robert; Grant, Paul J; Chaffee, Bruce W

    2015-12-01

    Computerized provider order entry systems commonly contain alerting mechanisms for patient allergies, incorrect doses, or drug-drug interactions when ordering medications. Providers have the option to override (bypass) these alerts and continue with the order unchanged. This study examines the effect of customizing medication alert override options on the appropriateness of override selection related to patient allergies, drug dosing, and drug-drug interactions when ordering medications in an electronic medical record. In this prospective, randomized crossover study, providers were randomized into cohorts that required a reason for overriding a medication alert from a customized or non-customized list of override reasons and/or by free-text entry. The primary outcome was to compare override responses that appropriately correlate with the alert type between the customized and non-customized configurations. The appropriateness of a subset of free-text responses that represented an affirmative and active acknowledgement of the alert without further explanation was classified as "indeterminate." Results were analyzed in three different ways by classifying indeterminate answers as either appropriate, inappropriate, or excluded entirely. Secondary outcomes included the appropriateness of override reasons when comparing cohorts and individual providers, reason selection based on order within the override list, and the determination of the frequency of free-text use, nonsensical responses, and multiple selection responses. Twenty-two clinicians were randomized into 2 cohorts and a total of 1829 alerts with a required response were generated during the study period. The customized configuration had a higher rate of appropriateness when compared to the non-customized configuration regardless of how indeterminate responses were classified (p<0.001). When comparing cohorts, appropriateness was significantly higher in the customized configuration regardless of the classification of indeterminate responses (p<0.001) with one exception: when indeterminate responses were considered inappropriate for the cohort of providers that were first exposed to the non-customized list (p=0.103). Free-text use was higher in the customized configuration overall (p<0.001), and there was no difference in nonsensical response between configurations (p=0.39). There is a benefit realized by using a customized list for medication override reasons. Poor application design or configuration can negatively affect provider behavior when responding to important medication alerts. Copyright © 2015. Published by Elsevier Ireland Ltd.

  1. Final Report Program Plan for Search and Rescue Electronics Alerting and Locating System

    DOT National Transportation Integrated Search

    1974-02-01

    This study investigates the requirements that exist for electronic devices for alerting and locating distress incidents and presents a plan for acquiring an adequate capability. Data are provided that bound the problem. Possible alternatives are exam...

  2. 75 FR 19559 - Public Safety and Homeland Security Bureau Seeks Informal Comment Regarding Revisions to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-15

    ..., cell phones and electronic highway signs. CAP will also allow an alert initiator to send alerts... CAP-formatted alerts delivered via any new delivery systems, whether wireline, internet, satellite, or...

  3. Limiting ventilator-induced lung injury through individual electronic medical record surveillance.

    PubMed

    Herasevich, Vitaly; Tsapenko, Mykola; Kojicic, Marija; Ahmed, Adil; Kashyap, Rachul; Venkata, Chakradhar; Shahjehan, Khurram; Thakur, Sweta J; Pickering, Brian W; Zhang, Jiajie; Hubmayr, Rolf D; Gajic, Ognjen

    2011-01-01

    To improve the safety of ventilator care and decrease the risk of ventilator-induced lung injury, we designed and tested an electronic algorithm that incorporates patient characteristics and ventilator settings, allowing near-real-time notification of bedside providers about potentially injurious ventilator settings. Electronic medical records of consecutive patients who received invasive ventilation were screened in three Mayo Clinic Rochester intensive care units. The computer system alerted bedside providers via the text paging notification about potentially injurious ventilator settings. Alert criteria included a Pao2/Fio2 ratio of <300 mm Hg, free text search for the words "edema" or "bilateral + infiltrates" on the chest radiograph report, a tidal volume of >8 mL/kg predicted body weight (based on patient gender and height), a plateau pressure of >30 cm H2O, and a peak airway pressure of >35 cm H2O. Respiratory therapists answered a brief online satisfaction survey. Ventilator-induced lung injury risk was compared before and after the introduction of ventilator-induced lung injury alert. The prevalence of acute lung injury was 42% (n = 490) among 1,159 patients receiving >24 hrs of invasive ventilation. The system sent 111 alerts for 80 patients, with a positive predictive value of 59%. The exposure to potentially injurious ventilation decreased after the intervention from 40.6 ± 74.6 hrs to 26.9 ± 77.3 hrs (p = .004). Electronic medical record surveillance of mechanically ventilated patients accurately detects potentially injurious ventilator settings and is able to influence bedside practice at moderate costs. Its implementation is associated with decreased patient exposure to potentially injurious mechanical ventilation settings.

  4. PleurAlert: an augmented chest drainage system with electronic sensing, automated alerts and internet connectivity.

    PubMed

    Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T

    2012-01-01

    We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.

  5. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  6. To act or not to act: responses to electronic health record prompts by family medicine clinicians.

    PubMed

    Zazove, Philip; McKee, Michael; Schleicher, Lauren; Green, Lee; Kileny, Paul; Rapai, Mary; Mulhem, Elie

    2017-03-01

    A major focus of health care today is a strong emphasis on improving the health and quality of care for entire patient populations. One common approach utilizes electronic clinical alerts to prompt clinicians when certain interventions are due for individual patients being seen. However, these alerts have not been consistently effective, particularly for less visible (though important) conditions such as hearing loss (HL) screening. We conducted hour-long cognitive task analysis interviews to explore how family medicine clinicians view, perceive, and use electronic clinical alerts, and to utilize this information to design a more effective alert using HL identification and referral as a model diagnosis. Four key direct barriers were identified that impeded alert use: poor standardization and formatting, time pressures in primary care, clinic workflow variations, and mental models of the condition being prompted (in this case, HL). One indirect barrier was identified: electronic health record and institution/government regulations. We identified that clinicians' mental model of the condition being prompted was probably the major barrier, though this was often expressed as time pressure. We discuss solutions to each of the 5 identified barriers, such as addressing physicians' mental models, by focusing on physicians' expertise rather than knowledge to improve their comfort when caring for patients with the conditions being prompted. To unleash the potential of electronic clinical alerts, electronic health record and health care institutions need to address some key barriers. We outline these barriers and propose solutions. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Personalized and automated remote monitoring of atrial fibrillation.

    PubMed

    Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita

    2016-03-01

    Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  8. Core drug-drug interaction alerts for inclusion in pediatric electronic health records with computerized prescriber order entry.

    PubMed

    Harper, Marvin B; Longhurst, Christopher A; McGuire, Troy L; Tarrago, Rod; Desai, Bimal R; Patterson, Al

    2014-03-01

    The study aims to develop a core set of pediatric drug-drug interaction (DDI) pairs for which electronic alerts should be presented to prescribers during the ordering process. A clinical decision support working group composed of Children's Hospital Association (CHA) members was developed. CHA Pharmacists and Chief Medical Information Officers participated. Consensus was reached on a core set of 19 DDI pairs that should be presented to pediatric prescribers during the order process. We have provided a core list of 19 high value drug pairs for electronic drug-drug interaction alerts to be recommended for inclusion as high value alerts in prescriber order entry software used with a pediatric patient population. We believe this list represents the most important pediatric drug interactions for practical implementation within computerized prescriber order entry systems.

  9. Digital frequency-offset detector

    NASA Technical Reports Server (NTRS)

    Bogart, R. W.; Juengst, M. J.

    1977-01-01

    Simple, low-cost device with designer-selectable tolerances provides accurate frequency comparison with minimal circuitry and ease of adjustment. Warning alerts if frequencies being compared fall outside selected tolerance. Device can be applied to any electronic system where accurate timing or frequency control is important.

  10. Electronic Health Record Alert-Related Workload as a Predictor of Burnout in Primary Care Providers.

    PubMed

    Gregory, Megan E; Russo, Elise; Singh, Hardeep

    2017-07-05

    Electronic health records (EHRs) have been shown to increase physician workload. One EHR feature that contributes to increased workload is asynchronous alerts (also known as inbox notifications) related to test results, referral responses, medication refill requests, and messages from physicians and other health care professionals. This alert-related workload results in negative cognitive outcomes, but its effect on affective outcomes, such as burnout, has been understudied. To examine EHR alert-related workload (both objective and subjective) as a predictor of burnout in primary care providers (PCPs), in order to ultimately inform interventions aimed at reducing burnout due to alert workload. A cross-sectional questionnaire and focus group of 16 PCPs at a large medical center in the southern United States. Subjective, but not objective, alert workload was related to two of the three dimensions of burnout, including physical fatigue (p = 0.02) and cognitive weariness (p = 0.04), when controlling for organizational tenure. To reduce alert workload and subsequent burnout, participants indicated a desire to have protected time for alert management, fewer unnecessary alerts, and improvements to the EHR system. Burnout associated with alert workload may be in part due to subjective differences at an individual level, and not solely a function of the objective work environment. This suggests the need for both individual and organizational-level interventions to improve alert workload and subsequent burnout. Additional research should confirm these findings in larger, more representative samples.

  11. Improving documentation of a beta-blocker quality measure through an anesthesia information management system and real-time notification of documentation errors.

    PubMed

    Nair, Bala G; Peterson, Gene N; Newman, Shu-Fang; Wu, Wei-Ying; Kolios-Morris, Vickie; Schwid, Howard A

    2012-06-01

    Continuation of perioperative beta-blockers for surgical patients who are receiving beta-blockers prior to arrival for surgery is an important quality measure (SCIP-Card-2). For this measure to be considered successful, name, date, and time of the perioperative beta-blocker must be documented. Alternately, if the beta-blocker is not given, the medical reason for not administering must be documented. Before the study was conducted, the institution lacked a highly reliable process to document the date and time of self-administration of beta-blockers prior to hospital admission. Because of this, compliance with the beta-blocker quality measure was poor (-65%). To improve this measure, the anesthesia care team was made responsible for documenting perioperative beta-blockade. Clear documentation guidelines were outlined, and an electronic Anesthesia Information Management System (AIMS) was configured to facilitate complete documentation of the beta-blocker quality measure. In addition, real-time electronic alerts were generated using Smart Anesthesia Messenger (SAM), an internally developed decision-support system, to notify users concerning incomplete beta-blocker documentation. Weekly compliance for perioperative beta-blocker documentation before the study was 65.8 +/- 16.6%, which served as the baseline value. When the anesthesia care team started documenting perioperative beta-blocker in AIMS, compliance was 60.5 +/- 8.6% (p = .677 as compared with baseline). Electronic alerts with SAM improved documentation compliance to 94.6 +/- 3.5% (p < .001 as compared with baseline). To achieve high compliance for the beta-blocker measure, it is essential to (1) clearly assign a medical team to perform beta-blocker documentation and (2) enhance features in the electronic medical systems to alert the user concerning incomplete documentation.

  12. Geo-targeted Weather Alerts Coming to Millions of Mobile Devices

    NASA Astrophysics Data System (ADS)

    Gerber, M.

    2011-12-01

    The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.

  13. INITIATE: An Intelligent Adaptive Alert Environment.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza

    2015-01-01

    Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.

  14. Best practices: an electronic drug alert program to improve safety in an accountable care environment.

    PubMed

    Griesbach, Sara; Lustig, Adam; Malsin, Luanne; Carley, Blake; Westrich, Kimberly D; Dubois, Robert W

    2015-04-01

    The accountable care organization (ACO), one of the most promising and talked about new models of care, focuses on improving communication and care transitions by tying potential shared savings to specific clinical and financial benchmarks. An important factor in meeting these benchmarks is an ACO's ability to manage medications in an environment where medical and pharmacy care has been integrated. The program described in this article highlights the critical components of Marshfield Clinic's Drug Safety Alert Program (DSAP), which focuses on prioritizing and communicating safety issues related to medications with the goal of reducing potential adverse drug events. Once the medication safety concern is identified, it is reviewed to evaluate whether an alert warrants sending prescribers a communication that identifies individual patients or a general communication to all physicians describing the safety concern. Instead of basing its decisions regarding clinician notification about drug alerts on subjective criteria, the Marshfield Clinic's DSAP uses an internally developed scoring system. The scoring system includes criteria developed from previous drug alerts, such as level of evidence, size of population affected, severity of adverse event identified or targeted, litigation risk, available alternatives, and potential for duration of medication use. Each of the 6 criteria is assigned a weight and is scored based upon the content and severity of the alert received.  In its first 12 months, the program targeted 6 medication safety concerns involving the following medications: topiramate, glyburide, simvastatin, citalopram, pioglitazone, and lovastatin. Baseline and follow-up prescribing data were gathered on the targeted medications. Follow-up review of prescribing data demonstrated that the DSAP provided quality up-to-date safety information that led to changes in drug therapy and to decreases in potential adverse drug events. In aggregate, nearly 10,000 total potential adverse drug events were identified with baseline data from the DSAP initiatives, and nearly 8,000 were resolved by changes in prescribing.  Implications and additional thoughts from The Working Group on Optimizing Medication Therapy in Value-Based Healthcare were provided for the following categories: leveraging electronic health records, importance of data collection and reassessment, preventing alert fatigue utilizing various techniques, relevance to ACO quality measurement, and limitations of a retrospective system. While health information technologies have been recognized as a cornerstone for an ACO's success, additional research is needed on comparing these types of technological innovations. Future research should focus on reviewing comparable scoring criteria and alert systems utilized in a variety of ACOs. In addition, an examination of different data mining procedures used within different electronic health record platforms would prove useful to ACOs looking to improve the care of not only the subpopulations with specific metrics associated with them, but their patient population as a whole. The authors also highlight the need for additional research on health information exchanges, including the cost and resource requirements needed to successfully participate in these types of networks.

  15. Impact of e-alert for detection of acute kidney injury on processes of care and outcomes: protocol for a systematic review and meta-analysis.

    PubMed

    Lachance, Philippe; Villeneuve, Pierre-Marc; Wilson, Francis P; Selby, Nicholas M; Featherstone, Robin; Rewa, Oleksa; Bagshaw, Sean M

    2016-05-05

    Acute kidney injury (AKI) is a common complication in hospitalised patients. It imposes significant risk for major morbidity and mortality. Moreover, patients suffering an episode of AKI consume considerable health resources. Recently, a number of studies have evaluated the implementation of automated electronic alerts (e-alerts) configured from electronic medical records (EMR) and clinical information systems (CIS) to warn healthcare providers of early or impending AKI in hospitalised patients. The impact of e-alerts on care processes, patient outcomes and health resource use, however, remains uncertain. We will perform a systematic review to describe and appraise e-alerts for AKI, and evaluate their impact on processes of care, clinical outcomes and health services use. In consultation with a research librarian, a search strategy will be developed and electronic databases (ie, MEDLINE, EMBASE, CINAHL, Cochrane Library and Inspec via Engineering Village) searched. Selected grey literature sources will also be searched. Search themes will focus on e-alerts and AKI. Citation screening, selection, quality assessment and data abstraction will be performed in duplicate. The primary analysis will be narrative; however, where feasible, pooled analysis will be performed. Each e-alert will be described according to trigger, type of alert, target recipient and degree of intrusiveness. Pooled effect estimates will be described, where applicable. Our systematic review will synthesise the literature on the value of e-alerts to detect AKI, and their impact on processes, patient-centred outcomes and resource use, and also identify key knowledge gaps and barriers to implementation. This is a fundamental step in a broader research programme aimed to understand the ideal structure of e-alerts, target population and methods for implementation, to derive benefit. Research ethics approval is not required for this review. CRD42016033033. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Notification of abnormal lab test results in an electronic medical record: do any safety concerns remain?

    PubMed Central

    Singh, Hardeep; Thomas, Eric J.; Sittig, Dean F.; Wilson, Lindsey; Espadas, Donna; Khan, Myrna M.; Petersen, Laura A.

    2010-01-01

    Background: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. Methods: We studied four alerts: hemoglobin A1c (HbA1c) ≥15%, positive hepatitis C antibody (HCV), prostate specific antigen (PSA) ≥15 ng/mL, and thyroid stimulating hormone (TSH) ≥ 15 mIU/L. An alert tracking system determined whether the alert was acknowledged (i.e. provider clicked on and opened the message) within two weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (e.g. patient contact, treatment etc.). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. Results: Between May 2008 and December 2008, 78,158 tests (HbA1c, HCV, TSH and PSA) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%) and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs. 10.1%; p =.13). Two-hundred two alerts (17.4% of 1163) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (OR: 7.35; 95% CI: 4.16-12.97) whereas alerts related to redundant tests were less likely to lack timely follow-up (OR: 0.24; 95% CI: 0.07-0.84). Conclusions: Safety concerns related to timely patient follow-up remain despite automated notification of non-life threatening abnormal laboratory results in the outpatient setting. PMID:20193832

  17. Development and Implementation of Sepsis Alert Systems.

    PubMed

    Harrison, Andrew M; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2016-06-01

    Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload, and alert fatigue, due to suboptimal alert performance. Outside the ICU, barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Current evidence does not support routine use of sepsis alert systems in clinical practice. Continuous improvement in the afferent and efferent aspects will help translate theoretic advantages into measurable patient benefit. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Development and implementation of sepsis alert systems

    PubMed Central

    Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly

    2016-01-01

    Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639

  19. Impact of e-alert systems on the care of patients with acute kidney injury.

    PubMed

    Breighner, Crystal M; Kashani, Kianoush B

    2017-09-01

    With the recent advancement in electronic health record systems and meaningful use of information technology incentive programs (i.e., the American Recovery and Reinvestment Act, the Health Information Technology for Economic and Clinical Health Act, and the Centers for Medicare & Medicaid Services), interest in clinical decision support systems has risen. These systems have been used to examine a variety of different syndromes with variable reported effects. In recent years, electronic alerts (e-alerts) have been implemented at various institutions to decrease the morbidity associated with acute kidney injury (AKI). AKI is common, accounting for 1 in 7 hospital admissions, and is associated with increased length of hospital stay and mortality. AKI is often underrecognized, causing delayed intervention. The use of e-alerts may result in earlier recognition and intervention, as well as decreased morbidity and mortality. This must be balanced with the possibility of increased resource utilization that e-alerts may cause. Before widespread implementation, the ethical and legal consequences of not following e-alert recommendations must be established, and the optimal algorithm for AKI e-alert detection must be determined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. The impact of the heparin-induced thrombocytopenia (HIT) computerized alert on provider behaviors and patient outcomes.

    PubMed

    Austrian, Jonathan S; Adelman, Jason S; Reissman, Stan H; Cohen, Hillel W; Billett, Henny H

    2011-01-01

    The aim of this study was to measure the effect of an electronic heparin-induced thrombocytopenia (HIT) alert on provider ordering behaviors and on patient outcomes. A pop-up alert was created for providers when an individual's platelet values had decreased by 50% or to <100,000/mm(3) in the setting of recent heparin exposure. The authors retrospectively compared inpatients admitted between January 24, 2008 and August 24, 2008 to a control group admitted 1 year prior to the HIT alert. The primary outcome was a change in HIT antibody testing. Secondary outcomes included an assessment of incidence of HIT antibody positivity, percentage of patients started on a direct thrombin inhibitor (DTI), length of stay and overall mortality. There were 1006 and 1081 patients in the control and intervention groups, respectively. There was a 33% relative increase in HIT antibody test orders (p=0.01), and 33% more of these tests were ordered the first day after the criteria were met when a pop-up alert was given (p=0.03). Heparin was discontinued in 25% more patients in the alerted group (p=0.01), and more direct thrombin inhibitors were ordered for them (p=0.03). The number who tested HIT antibody-positive did not differ, however, between the two groups (p=0.99). The length of stay and mortality were similar in both groups. The HIT alert significantly impacted provider behaviors. However, the alert did not result in more cases of HIT being detected or an improvement in overall mortality. Our findings do not support implementation of a computerized HIT alert.

  2. A trial of a real-time alert for clinical deterioration in patients hospitalized on general medical wards.

    PubMed

    Bailey, Thomas C; Chen, Yixin; Mao, Yi; Lu, Chenyang; Hackmann, Gregory; Micek, Scott T; Heard, Kevin M; Faulkner, Kelly M; Kollef, Marin H

    2013-05-01

    With limited numbers of intensive care unit (ICU) beds available, increasing patient acuity is expected to contribute to episodes of inpatient deterioration on general wards. To prospectively validate a predictive algorithm for clinical deterioration in general-medical ward patients, and to conduct a trial of real-time alerts based on this algorithm. Randomized, controlled crossover study. Academic center with patients hospitalized on 8 general wards between July 2007 and December 2011. Real-time alerts were generated by an algorithm designed to predict the need for ICU transfer using electronically available data. The alerts were sent by text page to the nurse manager on intervention wards. Intensive care unit transfer, hospital mortality, and hospital length of stay. Patients meeting the alert threshold were at nearly 5.3-fold greater risk of ICU transfer (95% confidence interval [CI]: 4.6-6.0) than those not satisfying the alert threshold (358 of 2353 [15.2%] vs 512 of 17678 [2.9%]). Patients with alerts were at 8.9-fold greater risk of death (95% CI: 7.4-10.7) than those without alerts (244 of 2353 [10.4%] vs 206 of 17678 [1.2%]). Among patients identified by the early warning system, there were no differences in the proportion of patients who were transferred to the ICU or who died in the intervention group as compared with the control group. Real-time alerts were highly specific for clinical deterioration resulting in ICU transfer and death, and were associated with longer hospital length of stay. However, an intervention notifying a nurse of the risk did not result in improvement in these outcomes. Copyright © 2013 Society of Hospital Medicine.

  3. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    PubMed

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  4. Visual Alert System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.

  5. Warfarin monitoring in nursing homes assessed by case histories. Do recommendations and electronic alerts affect judgements?

    PubMed

    Teruel, Reyes Serrano; Thue, Geir; Fylkesnes, Svein Ivar; Sandberg, Sverre; Kristoffersen, Ann Helen

    2017-09-01

    Older adults treated with warfarin are prone to complications, and high-quality monitoring is essential. The aim of this case history based study was to assess the quality of warfarin monitoring in a routine situation, and in a situation with an antibiotic-warfarin interaction, before and after receiving an electronic alert. In April 2014, a national web-based survey with two case histories was distributed among Norwegian nursing home physicians and general practitioners working part-time in nursing homes. Case A represented a patient on stable warfarin treatment, but with a substantial INR increase within the therapeutic interval. Case B represented a more challenging patient with trimethoprim sulfamethoxazole (TMS) treatment due to pyelonephritis. In both cases, the physicians were asked to state the next warfarin dose and the INR recall interval. In case B, the physicians could change their suggestions after receiving an electronic alert on the TMS-warfarin interaction. Three hundred and ninety eight physicians in 292 nursing homes responded. Suggested INR recall intervals and warfarin doses varied substantially in both cases. In case A, 61% gave acceptable answers according to published recommendations, while only 9% did so for case B. Regarding the TMS-warfarin interaction in case history B, the electronic alert increased the percentage of respondents correctly suggesting a dose reduction from 29% to 53%. Having an INR instrument in the nursing home was associated with shortened INR recall times. Practical advice on handling of warfarin treatment and drug interactions is needed. Electronic alerts as presented in electronic medical records seem insufficient to change practice. Availability of INR instruments may be important regarding recall time.

  6. The impact of a multifaceted intervention including sepsis electronic alert system and sepsis response team on the outcomes of patients with sepsis and septic shock.

    PubMed

    Arabi, Yaseen M; Al-Dorzi, Hasan M; Alamry, Ahmed; Hijazi, Ra'ed; Alsolamy, Sami; Al Salamah, Majid; Tamim, Hani M; Al-Qahtani, Saad; Al-Dawood, Abdulaziz; Marini, Abdellatif M; Al Ehnidi, Fatimah H; Mundekkadan, Shihab; Matroud, Amal; Mohamed, Mohamed S; Taher, Saadi

    2017-12-01

    Compliance with the clinical practice guidelines of sepsis management has been low. The objective of our study was to describe the results of implementing a multifaceted intervention including an electronic alert (e-alert) with a sepsis response team (SRT) on the outcome of patients with sepsis and septic shock presenting to the emergency department. This was a pre-post two-phased implementation study that consisted of a pre-intervention phase (January 01, 2011-September 24, 2012), intervention phase I (multifaceted intervention including e-alert, from September 25, 2012-March 03, 2013) and intervention phase II when SRT was added (March 04, 2013-October 30, 2013) in a 900-bed tertiary-care academic hospital. We recorded baseline characteristics and processes of care in adult patients presenting with sepsis or septic shock. The primary outcome measures were hospital mortality. Secondary outcomes were the need for mechanical ventilation and length of stay in the intensive unit and in the hospital. After implementing the multifaceted intervention including e-alert and SRT, cases were identified with less severe clinical and laboratory abnormalities and the processes of care improved. When adjusted to propensity score, the interventions were associated with reduction in hospital mortality [for intervention phase II compared to pre-intervention: adjusted odds ratio (aOR) 0.71, 95% CI 0.58-0.85, p = 0.003], reduction in the need for mechanical ventilation (aOR 0.45, 95% CI 0.37-0.55, p < 0.0001) and reduction in ICU LOS and hospital LOS for all patients as well as ICU LOS for survivors. Implementing a multifaceted intervention including sepsis e-alert with SRT was associated with earlier identification of sepsis, increase in compliance with sepsis resuscitation bundle and reduction in the need for mechanical ventilation and reduction in hospital mortality and LOS.

  7. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  8. Effectiveness of a real-time clinical decision support system for computerized physician order entry of plasma orders.

    PubMed

    Yazer, Mark H; Triulzi, Darrell J; Reddy, Vivek; Waters, Jonathan H

    2013-12-01

    We investigated the effect of implementing adaptive plasma ordering criteria in the computerized physician order entry (CPOE) system, with alerts that were automatically generated if the recipient's antecedent international normalized ratio (INR) did not meet the institutional criteria. In a regional health care system consisting of 11 hospitals using a common CPOE, data on the number of plasma orders and alerts that were generated were collected over a 4-month period before prescribers were required to select an indication for plasma. When adaptive ordering was implemented prescribers had to choose from prepopulated indications for plasma: INR of 1.6 or greater with bleeding, INR of 1.6 or greater before an invasive procedure, therapeutic exchange, massive transfusion, and other. Regardless of the antecedent INR the alert did not trigger if massive transfusion or plasmapheresis was selected. Information on prescribers and recipients was collected during this 5-month period. In the 4-month period before the adaptive alerts were implemented, 42.9% of the plasma orders generated an alert; in the 5-month period thereafter the alert rate was significantly lower at 27.9% (p < 0.0001). The percentage of heeded alerts increased during the adaptive alert period (24.3% vs. 17.1%, respectively, p = 0.004). A significant percentage (45%) of other plasma orders were for periprocedure or bleeding patients whose antecedent INR was less than 1.6. There were significant differences in prescriber specialties among those who ordered plasma using the other indication compared to all plasma orders. Electronic interventions improve compliance with plasma guidelines but as implemented are not sufficient to completely curtail non-evidence-based ordering. © 2013 American Association of Blood Banks.

  9. Impact of electronic-alerting of acute kidney injury: workgroup statements from the 15(th) ADQI Consensus Conference.

    PubMed

    Hoste, Eric A J; Kashani, Kianoush; Gibney, Noel; Wilson, F Perry; Ronco, Claudio; Goldstein, Stuart L; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Among hospitalized patients, acute kidney injury is common and associated with significant morbidity and risk for mortality. The use of electronic health records (EHR) for prediction and detection of this important clinical syndrome has grown in the past decade. The steering committee of the 15(th) Acute Dialysis Quality Initiative (ADQI) conference dedicated a workgroup with the task of identifying elements that may impact the course of events following Acute Kidney Injury (AKI) e-alert. Following an extensive, non-systematic literature search, we used a modified Delphi process to reach consensus regarding several aspects of the utilization of AKI e-alerts. Topics discussed in this workgroup included progress in evidence base practices, the characteristics of an optimal e-alert, the measures of efficacy and effectiveness, and finally what responses would be considered best practices following AKI e-alerts. Authors concluded that the current evidence for e-alert system efficacy, although growing, remains insufficient. Technology and human-related factors were found to be crucial elements of any future investigation or implementation of such tools. The group also concluded that implementation of such systems should not be done without a vigorous plan to evaluate the efficacy and effectiveness of e-alerts. Efficacy and effectiveness of e-alerts should be measured by context-specific process and patient outcomes. Finally, the group made several suggestions regarding the clinical decision support that should be considered following successful e-alert implementation. This paper reflects the findings of a non-systematic review and expert opinion. We recommend implementation of the findings of this workgroup report for use of AKI e-alerts.

  10. Validation of Test Performance and Clinical Time Zero for an Electronic Health Record Embedded Severe Sepsis Alert

    PubMed Central

    Downing, N. Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa

    2016-01-01

    Summary Bachground Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. Objective To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. Methods The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Results Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. Conclusion We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems. PMID:27437061

  11. Validation of Test Performance and Clinical Time Zero for an Electronic Health Record Embedded Severe Sepsis Alert.

    PubMed

    Rolnick, Joshua; Downing, N Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa

    2016-01-01

    Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems.

  12. Evening electronic device use: The effects on alertness, sleep and next-day physical performance in athletes.

    PubMed

    Jones, Maddison J; Peeling, Peter; Dawson, Brian; Halson, Shona; Miller, Joanna; Dunican, Ian; Clarke, Michael; Goodman, Carmel; Eastwood, Peter

    2018-01-01

    The aim of the present study was to investigate the influence of different types of tasks performed with or without an electronic device (tablet) on pre-sleep alertness, subsequent sleep quality and next-day athletic performance. Eight highly trained netball players attended a sleep laboratory for pre-sleep testing, polysomnographic sleep monitoring and next-day physical performance testing on 5 separate occasions (1 familiarisation and 4 experimental sessions). For 2 h prior to bedtime, athletes completed cognitively stimulating tasks (puzzles) or passive tasks (reading) with or without a tablet. Sleepiness tended to be greater after reading compared to completing puzzles without a tablet (d = 0.80), but not with a tablet. Melatonin concentration increased more so after reading compared to completing puzzles on a tablet (P = 0.02). There were no significant differences in sleep quality or quantity or next-day athletic performance between any of the conditions. These data suggest that using a tablet for 2 h prior to sleep does not negatively affect subsequent sleep or next-day performance in athletes.

  13. Subjective assessment of usefulness and appropriate presentation mode of alerts and reminders in the outpatient setting.

    PubMed Central

    Krall, M. A.; Sittig, D. F.

    2001-01-01

    There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use". PMID:11825206

  14. Subjective assessment of usefulness and appropriate presentation mode of alerts and reminders in the outpatient setting.

    PubMed

    Krall, M A; Sittig, D F

    2001-01-01

    There is very little known about the limits of alerting in the setting of the outpatient Electronic Medical Record (EMR). We are interested in how users value and prefer such alerts. One hundred Kaiser Permanente primary care clinicians were sent a four-page questionnaire. It contained questions related to the usability and usefulness of different approaches to presenting reminder and alert information. The survey also contained questions about the desirability of six categories of alerts. Forty-three of 100 questionnaires were returned. Users generally preferred an active, more intrusive interaction model for "alerts" and a passive, less intrusive model for order messages and other types of reminders and notifications. Drug related alerts were more highly rated than health maintenance or disease state reminders. Users indicated that more alerts would make the system "more useful" but "less easy to use".

  15. Audit of radiology communication systems for critical, urgent, and unexpected significant findings.

    PubMed

    Duncan, K A; Drinkwater, K J; Dugar, N; Howlett, D C

    2016-03-01

    To determine the compliance of UK radiology departments and trusts/healthcare organisations with National Patient Safety Agency and Royal College of Radiologist's published guidance on the communication of critical, urgent, and unexpected significant radiological findings. A questionnaire was sent to all UK radiology department audit leads asking for details of their current departmental policy regarding the issuing of alerts; use of automated electronic alert systems; methods of notification of clinicians of critical, urgent, and unexpected significant radiological findings; monitoring of results receipt; and examples of the more common types of serious pathologies for which alerts were issued. One hundred and fifty-four of 229 departments (67%) responded. Eighty-eight percent indicated that they had a policy in place for the communication of critical, urgent, and unexpected significant radiological findings. Only 34% had an automated electronic alert system in place and only 17% had a facility for service-wide electronic tracking of radiology reports. In only 11 departments with an electronic acknowledgement system was someone regularly monitoring the read rate. There is wide variation in practice across the UK with regard to the communication and monitoring of reports with many departments/trusts not fully compliant with published UK guidance. Despite the widespread use of electronic systems, only a minority of departments/trusts have and use electronic tracking to ensure reports have been read and acted upon. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Automated inhaled nitric oxide alerts for adult extracorporeal membrane oxygenation patient identification.

    PubMed

    Belenkiy, Slava M; Batchinsky, Andriy I; Park, Timothy S; Luellen, David E; Serio-Melvin, Maria L; Cancio, Leopoldo C; Pamplin, Jeremy C; Chung, Kevin K; Salinas, Josè; Cannon, Jeremy W

    2014-09-01

    Recently, automated alerts have been used to identify patients with respiratory failure based on set criteria, which can be gleaned from the electronic medical record (EMR). Such an approach may also be useful for identifying patients with severe adult respiratory distress syndrome (ARDS) who may benefit from extracorporeal membrane oxygenation (ECMO). Inhaled nitric oxide (iNO) is a common rescue therapy for severe ARDS which can be easily tracked in the EMR, and some patients started on iNO may have indications for initiating ECMO. This case series summarizes our experience with using automated electronic alerts for ECMO team activation focused particularly on an alert triggered by the initiation of iNO. After a brief trial evaluation, our Smart Alert system generated an automated page and e-mail alert to ECMO team members whenever a nonzero value for iNO appeared in the respiratory care section of our EMR. If iNO was initiated for severe respiratory failure, a detailed evaluation by the ECMO team determined if ECMO was indicated. For those patients managed with ECMO, we tabulated baseline characteristics, indication for ECMO, and outcomes. From September 2012 to July 2013, 45 iNO alerts were generated on 42 unique patients. Six patients (14%) met criteria for ECMO. Of these, four were identified exclusively by the iNO alert. At the time of the alert, the median PaO₂-to-FIO₂ ratio was 64 mm Hg (range, 55-107 mm Hg), the median age-adjusted oxygenation index was 73 (range, 51-96), and the median Murray score was 3.4 (range, 3-3.75), indicating severe respiratory failure. Median time from iNO alert to ECMO initiation was 81 hours (range, -2-292 hours). Survival to hospital discharge was 83% in those managed with ECMO. Automated alerts may be useful for identifying patients with severe ARDS who may be ECMO candidates. Diagnostic test, level V.

  17. Using the diffusion of innovations theory to assess socio-technical factors in planning the implementation of an electronic health record alert across multiple primary care clinics.

    PubMed

    Lin, Ching-Pin; Guirguis-Blake, Janelle; Keppel, Gina A; Dobie, Sharon; Osborn, Justin; Cole, Allison M; Baldwin, Laura-Mae

    2016-04-15

    Adverse drug events (ADEs) are a leading cause of death in the United States. Patients with stage 3 and 4 chronic kidney disease (CKD) are at particular risk because many medications are cleared by the kidneys. Alerts in the electronic health record (EHR) about drug appropriateness and dosing at the time of prescription have been shown to reduce ADEs for patients with stage 3 and 4 CKD in inpatient settings, but more research is needed about the implementation and effectiveness of such alerts in outpatient settings.  To explore factors that might inform the implementation of an electronic drug-disease alert for patients with CKD in primary care clinics, using Rogers' diffusion of innovations theory as an analytic framework. Interviews were conducted with key informants in four diverse clinics using various EHR systems. Interviews were audio recorded and transcribed. results Although all clinics had a current method for calculating glomerular filtration rate (GFR), clinics were heterogeneous with regard to current electronic decision support practices, quality improvement resources, and organizational culture and structure. Understanding variation in organizational culture and infrastructure across primary care clinics is important in planning implementation of an intervention to reduce ADEs among patients with CKD.

  18. Incidence of potential drug interactions in a transplant centre setting and relevance of electronic alerts for clinical practice support.

    PubMed

    Polidori, Piera; Di Giorgio, Concetta; Provenzani, Alessio

    2012-01-01

    Adverse drug events may occur as a result of drug-drug interactions (DDIs). Information technology (IT) systems can be an important decision-making tool for healthcare workers to identify DDIs. The aim of the study is to analyse drug prescriptions in our main hospital units, in order to measure the incidence and severity of potential DDIs. The utility of clinical decision-support systems (CDSSs) and computerised physician order entry (CPOE) in term of alerts adherence was also assessed. DDIs were assessed using a Micromedex® healthcare series database. The system, adopted by the hospital, generates alerts for prescriptions with negative interactions and thanks to an 'acknowledgement function' it is possible to verify physician adherence to alerts. This function, although used previously, became mandatory from September 2010. Physician adherence to alerts and mean monthly incidence of potential DDIs in analysed units, before and after the mandatory 'acknowledgement function', were calculated. The intensive care unit (ICU) registered the greatest incidence of potential DDIs (49.0%), followed by the abdominal surgery unit and dialysis (43.4 and 42.0%, respectively). The cardiothoracic surgery unit (41.6%), step-down unit (38.3%) and post-anaesthesia care unit (30.0%) were comparable. The operating theatre and endoscopy registered the fewest potential DDIs (28.2 and 22.7%, respectively). Adherence to alerts after the 'acknowledgement function' increased by 25.0% in the ICU, 54.0% in the cardiothoracic surgery unit, 52.5% in the abdominal surgery unit, 58.0% in the stepdown unit, 67.0% in dialysis, 51.0% in endoscopy and 48.0% in the post-anaesthesia care unit. In the operating theatre, adherence to alerts decreased from 34.0 to 30.0%. The incidence of potential DDIs after mandatory use of the 'acknowledgement function' decreased slightly in endoscopy (-2.9%), the abdominal surgery unit (-2.7%), dialysis (-1.9%) and the step-down unit (-1.4%). Improving DDI alerts will improved patient safety by more appropriately alerting clinicians.

  19. Optimizing drug-dose alerts using commercial software throughout an integrated health care system.

    PubMed

    Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C

    2017-11-01

    All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Development and preliminary evidence for the validity of an instrument assessing implementation of human-factors principles in medication-related decision-support systems—I-MeDeSA

    PubMed Central

    Zachariah, Marianne; Seidling, Hanna M; Neri, Pamela M; Cresswell, Kathrin M; Duke, Jon; Bloomrosen, Meryl; Volk, Lynn A; Bates, David W

    2011-01-01

    Background Medication-related decision support can reduce the frequency of preventable adverse drug events. However, the design of current medication alerts often results in alert fatigue and high over-ride rates, thus reducing any potential benefits. Methods The authors previously reviewed human-factors principles for relevance to medication-related decision support alerts. In this study, instrument items were developed for assessing the appropriate implementation of these human-factors principles in drug–drug interaction (DDI) alerts. User feedback regarding nine electronic medical records was considered during the development process. Content validity, construct validity through correlation analysis, and inter-rater reliability were assessed. Results The final version of the instrument included 26 items associated with nine human-factors principles. Content validation on three systems resulted in the addition of one principle (Corrective Actions) to the instrument and the elimination of eight items. Additionally, the wording of eight items was altered. Correlation analysis suggests a direct relationship between system age and performance of DDI alerts (p=0.0016). Inter-rater reliability indicated substantial agreement between raters (κ=0.764). Conclusion The authors developed and gathered preliminary evidence for the validity of an instrument that measures the appropriate use of human-factors principles in the design and display of DDI alerts. Designers of DDI alerts may use the instrument to improve usability and increase user acceptance of medication alerts, and organizations selecting an electronic medical record may find the instrument helpful in meeting their clinicians' usability needs. PMID:21946241

  1. Using the World Wide Web for GIDEP Problem Data Processing at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    McPherson, John W.; Haraway, Sandra W.; Whirley, J. Don

    1999-01-01

    Since April 1997, Marshall Space Flight Center has been using electronic transfer and the web to support our processing of the Government-Industry Data Exchange Program (GIDEP) and NASA ALERT information. Specific aspects include: (1) Extraction of ASCII text information from GIDEP for loading into Word documents for e-mail to ALERT actionees; (2) Downloading of GIDEP form image formats in Adobe Acrobat (.pdf) for internal storage display on the MSFC ALERT web page; (3) Linkage of stored GRDEP problem forms with summary information for access from the MSFC ALERT Distribution Summary Chart or from an html table of released MSFC ALERTs (4) Archival of historic ALERTs for reference by GIDEP ID, MSFC ID, or MSFC release date; (5) On-line tracking of ALERT response status using a Microsoft Access database and the web (6) On-line response to ALERTs from MSFC actionees through interactive web forms. The technique, benefits, effort, coordination, and lessons learned for each aspect are covered herein.

  2. Impact of an emergency department electronic sepsis surveillance system on patient mortality and length of stay.

    PubMed

    Austrian, Jonathan S; Jamin, Catherine T; Doty, Glenn R; Blecker, Saul

    2018-05-01

    The purpose of this study was to determine whether an electronic health record-based sepsis alert system could improve quality of care and clinical outcomes for patients with sepsis. We performed a patient-level interrupted time series study of emergency department patients with severe sepsis or septic shock between January 2013 and April 2015. The intervention, introduced in February 2014, was a system of interruptive sepsis alerts triggered by abnormal vital signs or laboratory results. Primary outcomes were length of stay (LOS) and in-hospital mortality; other outcomes included time to first lactate and blood cultures prior to antibiotics. We also assessed sensitivity, positive predictive value (PPV), and clinician response to the alerts. Mean LOS for patients with sepsis decreased from 10.1 to 8.6 days (P < .001) following alert introduction. In adjusted time series analysis, the intervention was associated with a decreased LOS of 16% (95% CI, 5%-25%; P = .007, with significance of α = 0.006) and no change thereafter (0%; 95% CI, -2%, 2%). The sepsis alert system had no effect on mortality or other clinical or process measures. The intervention had a sensitivity of 80.4% and a PPV of 14.6%. Alerting based on simple laboratory and vital sign criteria was insufficient to improve sepsis outcomes. Alert fatigue due to the low PPV is likely the primary contributor to these results. A more sophisticated algorithm for sepsis identification is needed to improve outcomes.

  3. Role of data aggregation in biosurveillance detection strategies with applications from ESSENCE.

    PubMed

    Burkom, Howard S; Elbert, Y; Feldman, A; Lin, J

    2004-09-24

    Syndromic surveillance systems are used to monitor daily electronic data streams for anomalous counts of features of varying specificity. The monitored quantities might be counts of clinical diagnoses, sales of over-the-counter influenza remedies, school absenteeism among a given age group, and so forth. Basic data-aggregation decisions for these systems include determining which records to count and how to group them in space and time. This paper discusses the application of spatial and temporal data-aggregation strategies for multiple data streams to alerting algorithms appropriate to the surveillance region and public health threat of interest. Such a strategy was applied and evaluated for a complex, authentic, multisource, multiregion environment, including >2 years of data records from a system-evaluation exercise for the Defense Advanced Research Project Agency (DARPA). Multivariate and multiple univariate statistical process control methods were adapted and applied to the DARPA data collection. Comparative parametric analyses based on temporal aggregation were used to optimize the performance of these algorithms for timely detection of a set of outbreaks identified in the data by a team of epidemiologists. The sensitivity and timeliness of the most promising detection methods were tested at empirically calculated thresholds corresponding to multiple practical false-alert rates. Even at the strictest false-alert rate, all but one of the outbreaks were detected by the best method, and the best methods achieved a 1-day median time before alert over the set of test outbreaks. These results indicate that a biosurveillance system can provide a substantial alerting-timeliness advantage over traditional public health monitoring for certain outbreaks. Comparative analyses of individual algorithm results indicate further achievable improvement in sensitivity and specificity.

  4. Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation

    PubMed Central

    Norris, Patrick R.; Dawant, Benoit M.

    2002-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.

  5. Reducing warfarin medication interactions: an interrupted time series evaluation.

    PubMed

    Feldstein, Adrianne C; Smith, David H; Perrin, Nancy; Yang, Xiuhai; Simon, Steven R; Krall, Michael; Sittig, Dean F; Ditmer, Diane; Platt, Richard; Soumerai, Stephen B

    2006-05-08

    Computerized decision support reduces medication errors in inpatients, but limited evidence supports its effectiveness in reducing the coprescribing of interacting medications, especially in the outpatient setting. The usefulness of academic detailing to enhance the effectiveness of medication interaction alerts also is uncertain. This study used an interrupted time series design. In a health maintenance organization with an electronic medical record, we evaluated the effectiveness of electronic medical record alerts and group academic detailing to reduce the coprescribing of warfarin and interacting medications. Participants were 239 primary care providers at 15 primary care clinics and 9910 patients taking warfarin. All 15 clinics received electronic medical record alerts for the coprescription of warfarin and 5 interacting medications: acetaminophen, nonsteroidal anti-inflammatory medications, fluconazole, metronidazole, and sulfamethoxazole. Seven clinics were randomly assigned to receive group academic detailing. The primary outcome, the interacting prescription rate (ie, the number of coprescriptions of warfarin-interacting medications per 10 000 warfarin users per month), was analyzed with segmented regression models, controlling for preintervention trends. At baseline, nearly a third of patients had an interacting prescription. Coinciding with the alerts, there was an immediate and continued reduction in the warfarin-interacting medication prescription rate (from 3294.0 to 2804.2), resulting in a 14.9% relative reduction (95% confidence interval, -19.5 to -10.2) at 12 months. Group academic detailing did not enhance alert effectiveness. This study, using a strong and quasi-experimental design in ambulatory care, found that medication interaction alerts modestly reduced the frequency of coprescribing of interacting medications. Additional efforts will be required to further reduce rates of inappropriate prescribing of warfarin with interacting drugs.

  6. Diagnostic accuracy and effectiveness of automated electronic sepsis alert systems: A systematic review.

    PubMed

    Makam, Anil N; Nguyen, Oanh K; Auerbach, Andrew D

    2015-06-01

    Although timely treatment of sepsis improves outcomes, delays in administering evidence-based therapies are common. To determine whether automated real-time electronic sepsis alerts can: (1) accurately identify sepsis and (2) improve process measures and outcomes. We systematically searched MEDLINE, Embase, The Cochrane Library, and Cumulative Index to Nursing and Allied Health Literature from database inception through June 27, 2014. Included studies that empirically evaluated 1 or both of the prespecified objectives. Two independent reviewers extracted data and assessed the risk of bias. Diagnostic accuracy of sepsis identification was measured by sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratio (LR). Effectiveness was assessed by changes in sepsis care process measures and outcomes. Of 1293 citations, 8 studies met inclusion criteria, 5 for the identification of sepsis (n = 35,423) and 5 for the effectiveness of sepsis alerts (n = 6894). Though definition of sepsis alert thresholds varied, most included systemic inflammatory response syndrome criteria ± evidence of shock. Diagnostic accuracy varied greatly, with PPV ranging from 20.5% to 53.8%, NPV 76.5% to 99.7%, LR+ 1.2 to 145.8, and LR- 0.06 to 0.86. There was modest evidence for improvement in process measures (ie, antibiotic escalation), but only among patients in non-critical care settings; there were no corresponding improvements in mortality or length of stay. Minimal data were reported on potential harms due to false positive alerts. Automated sepsis alerts derived from electronic health data may improve care processes but tend to have poor PPV and do not improve mortality or length of stay. © 2015 Society of Hospital Medicine.

  7. Diagnostic Accuracy and Effectiveness of Automated Electronic Sepsis Alert Systems: A Systematic Review

    PubMed Central

    Makam, Anil N.; Nguyen, Oanh K.; Auerbach, Andrew D.

    2015-01-01

    Background Although timely treatment of sepsis improves outcomes, delays in administering evidence-based therapies are common. Purpose To determine whether automated real-time electronic sepsis alerts can: 1) accurately identify sepsis, and 2) improve process measures and outcomes. Data Sources We systematically searched MEDLINE, Embase, The Cochrane Library, and CINAHL from database inception through June 27, 2014. Study Selection Included studies that empirically evaluated one or both of the prespecified objectives. Data Extraction Two independent reviewers extracted data and assessed the risk of bias. Diagnostic accuracy of sepsis identification was measured by sensitivity, specificity, positive (PPV) and negative predictive values (NPV) and likelihood ratios (LR). Effectiveness was assessed by changes in sepsis care process measures and outcomes. Data Synthesis Of 1,293 citations, 8 studies met inclusion criteria, 5 for the identification of sepsis (n=35,423) and 5 for the effectiveness of sepsis alerts (n=6,894). Though definition of sepsis alert thresholds varied, most included systemic inflammatory response syndrome criteria ± evidence of shock. Diagnostic accuracy varied greatly, with PPV ranging from 20.5-53.8%, NPV 76.5-99.7%; LR+ 1.2-145.8; and LR- 0.06-0.86. There was modest evidence for improvement in process measures (i.e., antibiotic escalation), but only among patients in non-critical care settings; there were no corresponding improvements in mortality or length of stay. Minimal data were reported on potential harms due to false positive alerts. Conclusions Automated sepsis alerts derived from electronic health data may improve care processes but tend to have poor positive predictive value and do not improve mortality or length of stay. PMID:25758641

  8. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation

    PubMed Central

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-01-01

    Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841

  9. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation.

    PubMed

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-10-01

    To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Evening use of light-emitting eReaders negatively affects sleep, circadian timing, and next-morning alertness

    PubMed Central

    Chang, Anne-Marie; Aeschbach, Daniel; Duffy, Jeanne F.; Czeisler, Charles A.

    2015-01-01

    In the past 50 y, there has been a decline in average sleep duration and quality, with adverse consequences on general health. A representative survey of 1,508 American adults recently revealed that 90% of Americans used some type of electronics at least a few nights per week within 1 h before bedtime. Mounting evidence from countries around the world shows the negative impact of such technology use on sleep. This negative impact on sleep may be due to the short-wavelength–enriched light emitted by these electronic devices, given that artificial-light exposure has been shown experimentally to produce alerting effects, suppress melatonin, and phase-shift the biological clock. A few reports have shown that these devices suppress melatonin levels, but little is known about the effects on circadian phase or the following sleep episode, exposing a substantial gap in our knowledge of how this increasingly popular technology affects sleep. Here we compare the biological effects of reading an electronic book on a light-emitting device (LE-eBook) with reading a printed book in the hours before bedtime. Participants reading an LE-eBook took longer to fall asleep and had reduced evening sleepiness, reduced melatonin secretion, later timing of their circadian clock, and reduced next-morning alertness than when reading a printed book. These results demonstrate that evening exposure to an LE-eBook phase-delays the circadian clock, acutely suppresses melatonin, and has important implications for understanding the impact of such technologies on sleep, performance, health, and safety. PMID:25535358

  11. Evening use of light-emitting eReaders negatively affects sleep, circadian timing, and next-morning alertness.

    PubMed

    Chang, Anne-Marie; Aeschbach, Daniel; Duffy, Jeanne F; Czeisler, Charles A

    2015-01-27

    In the past 50 y, there has been a decline in average sleep duration and quality, with adverse consequences on general health. A representative survey of 1,508 American adults recently revealed that 90% of Americans used some type of electronics at least a few nights per week within 1 h before bedtime. Mounting evidence from countries around the world shows the negative impact of such technology use on sleep. This negative impact on sleep may be due to the short-wavelength-enriched light emitted by these electronic devices, given that artificial-light exposure has been shown experimentally to produce alerting effects, suppress melatonin, and phase-shift the biological clock. A few reports have shown that these devices suppress melatonin levels, but little is known about the effects on circadian phase or the following sleep episode, exposing a substantial gap in our knowledge of how this increasingly popular technology affects sleep. Here we compare the biological effects of reading an electronic book on a light-emitting device (LE-eBook) with reading a printed book in the hours before bedtime. Participants reading an LE-eBook took longer to fall asleep and had reduced evening sleepiness, reduced melatonin secretion, later timing of their circadian clock, and reduced next-morning alertness than when reading a printed book. These results demonstrate that evening exposure to an LE-eBook phase-delays the circadian clock, acutely suppresses melatonin, and has important implications for understanding the impact of such technologies on sleep, performance, health, and safety.

  12. Outlier Detection for Patient Monitoring and Alerting

    PubMed Central

    Hauskrecht, Milos; Batal, Iyad; Valko, Michal; Visweswaran, Shyam; Cooper, Gregory F.; Clermont, Gilles

    2012-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management decisions using past patient cases stored in electronic health records (EHRs). Our hypothesis is that a patient-management decision that is unusual with respect to past patient care may be due to an error and that it is worthwhile to generate an alert if such a decision is encountered. We evaluate this hypothesis using data obtained from EHRs of 4,486 post-cardiac surgical patients and a subset of 222 alerts generated from the data. We base the evaluation on the opinions of a panel of experts. The results of the study support our hypothesis that the outlier-based alerting can lead to promising true alert rates. We observed true alert rates that ranged from 25% to 66% for a variety of patient-management actions, with 66% corresponding to the strongest outliers. PMID:22944172

  13. Alerts in electronic medical records to promote a colorectal cancer screening programme: a cluster randomised controlled trial in primary care.

    PubMed

    Guiriguet, Carolina; Muñoz-Ortiz, Laura; Burón, Andrea; Rivero, Irene; Grau, Jaume; Vela-Vallespín, Carmen; Vilarrubí, Mercedes; Torres, Miquel; Hernández, Cristina; Méndez-Boo, Leonardo; Toràn, Pere; Caballeria, Llorenç; Macià, Francesc; Castells, Antoni

    2016-07-01

    Participation rates in colorectal cancer screening are below recommended European targets. To evaluate the effectiveness of an alert in primary care electronic medical records (EMRs) to increase individuals' participation in an organised, population-based colorectal cancer screening programme when compared with usual care. Cluster randomised controlled trial in primary care centres of Barcelona, Spain. Participants were males and females aged 50-69 years, who were invited to the first round of a screening programme based on the faecal immunochemical test (FIT) (n = 41 042), and their primary care professional. The randomisation unit was the physician cluster (n = 130) and patients were blinded to the study group. The control group followed usual care as per the colorectal cancer screening programme. In the intervention group, as well as usual care, an alert to health professionals (cluster level) to promote screening was introduced in the individual's primary care EMR for 1 year. The main outcome was colorectal cancer screening participation at individual participant level. In total, 67 physicians and 21 619 patients (intervention group) and 63 physicians and 19 423 patients (control group) were randomised. In the intention-to-treat analysis screening participation was 44.1% and 42.2% respectively (odds ratio 1.08, 95% confidence interval [CI] = 0.97 to 1.20, P = 0.146). However, in the per-protocol analysis screening uptake in the intervention group showed a statistically significant increase, after adjusting for potential confounders (OR, 1.11; 95% CI = 1.02 to 1.22; P = 0.018). The use of an alert in an individual's primary care EMR is associated with a statistically significant increased uptake of an organised, FIT-based colorectal cancer screening programme in patients attending primary care centres. © British Journal of General Practice 2016.

  14. Contributors to Frequent Telehealth Alerts Including False Alerts for Patients with Heart Failure: A Mixed Methods Exploration

    PubMed Central

    Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.

    2013-01-01

    Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576

  15. Effects of a computerized feedback intervention on safety performance by junior doctors: results from a randomized mixed method study

    PubMed Central

    2013-01-01

    Background The behaviour of doctors and their responses to warnings can inform the effective design of Clinical Decision Support Systems. We used data from a University hospital electronic prescribing and laboratory reporting system with hierarchical warnings and alerts to explore junior doctors’ behaviour. The objective of this trial was to establish whether a Junior Doctor Dashboard providing feedback on prescription warning information and laboratory alerting acceptance rates was effective in changing junior doctors’ behaviour. Methods A mixed methods approach was employed which included a parallel group randomised controlled trial, and individual and focus group interviews. Junior doctors below the specialty trainee level 3 grade were recruited and randomised to two groups. Every doctor (N = 42) in the intervention group was e-mailed a link to a personal dashboard every week for 4 months. Nineteen participated in interviews. The 44 control doctors did not receive any automated feedback. The outcome measures were the difference in responses to prescribing warnings (of two severities) and laboratory alerting (of two severities) between the months before and the months during the intervention, analysed as the difference in performance between the intervention and the control groups. Results No significant differences were observed in the rates of generating prescription warnings, or in the acceptance of laboratory alarms. However, responses to laboratory alerts differed between the pre-intervention and intervention periods. For the doctors of Foundation Year 1 grade, this improvement was significantly (p = 0.002) greater in the group with access to the dashboard (53.6% ignored pre-intervention compared to 29.2% post intervention) than in the control group (47.9% ignored pre-intervention compared to 47.0% post intervention). Qualitative interview data indicated that while junior doctors were positive about the electronic prescribing functions, they were discriminating in the way they responded to other alerts and warnings given that from their perspective these were not always immediately clinically relevant or within the scope of their responsibility. Conclusions We have only been able to provide weak evidence that a clinical dashboard providing individualized feedback data has the potential to improve safety behaviour and only in one of several domains. The construction of metrics used in clinical dashboards must take account of actual work processes. Trial registration ISRCTN: ISRCTN72253051 PMID:23734871

  16. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254

  17. Closing the loop in ICU decision support: physiologic event detection, alerts, and documentation.

    PubMed Central

    Norris, P. R.; Dawant, B. M.

    2001-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility. PMID:11825238

  18. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    PubMed

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  19. Computerized Dose Range Checking Using Hard and Soft Stop Alerts Reduces Prescribing Errors in a Pediatric Intensive Care Unit.

    PubMed

    Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda

    2017-09-01

    An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.

  20. Electronic Alerts, Comparative Practitioner Metrics, and Education Improves Thromboprophylaxis and Reduces Thrombosis.

    PubMed

    Woller, Scott C; Stevens, Scott M; Evans, R Scott; Wray, Daniel G; Christensen, John C; Aston, Valerie T; Wayne, Matthew H; Lloyd, James F; Wilson, Emily L; Elliott, C Gregory

    2016-10-01

    Venous thromboembolism chemoprophylaxis remains underutilized in hospitalized medical patients at high risk for venous thromboembolism. We assessed the effect of a health care quality-improvement initiative comprised of a targeted electronic alert, comparative practitioner metrics, and practitioner-specific continuing medical education on the rate of appropriate venous thromboembolism chemoprophylaxis provided to medical inpatients at high risk for venous thromboembolism. We performed a multicenter prospective observational cohort study in an urban Utah hospital system. All medical patients admitted to 1 of 2 participating hospitals from April 1, 2010 to December 31, 2012 were eligible. Patients were members of the "control" (April 1, 2010 to December 31, 2010), "intervention" (January 1, 2011 to December 31, 2011), or "subsequent year" (January 1, 2012 to December 31, 2012) group. The primary outcome was the rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism. Secondary outcomes included rates of symptomatic venous thromboembolism, major bleeding, all-cause mortality, heparin-induced thrombocytopenia, physician satisfaction, and alert fatigue. The rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism increased (66.1% control period vs 81.0% intervention period vs 88.1% subsequent year; P <.001 for each comparison). A significant reduction of 90-day symptomatic venous thromboembolism accompanied the quality initiative (9.3% control period, 9.7% intervention period, 6.7% subsequent year; P = .009); 30-day venous thromboembolism rates also significantly decreased. A multifaceted intervention was associated with increased appropriate venous thromboembolism chemoprophylaxis among medical inpatients at high risk for venous thromboembolism and reduced symptomatic venous thromboembolism. The effect of the intervention was sustained. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Real time alert system: a disease management system leveraging health information exchange.

    PubMed

    Anand, Vibha; Sheley, Meena E; Xu, Shawn; Downs, Stephen M

    2012-01-01

    Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA's performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Our results show that RTA was successfully able to deliver "just in time" patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient's asthma related emergency room admission so further follow up can happen in near real time.

  2. Using Heuristic Evaluation to Improve Sepsis Alert Usability.

    PubMed

    Pertiwi, Ariani Arista Putri; Fraczkowski, Dan; Stogis, Sheryl L; Lopez, Karen Dunn

    2018-06-01

    Sepsis, life-threatening organ dysfunction in response to infection, is an alarmingly common and aggressive illness in US hospitals, especially for intensive care patients. Preventing sepsis deaths rests on the clinicians' ability to promptly recognize and treat sepsis. To aid early recognition, many organizations have employed clinician-facing electronic sepsis alert systems. However, the effectiveness of the alert relies on heavily on the visual interface, textual information, and overall usability. This article reports a usability inspection of a sepsis alert system. The authors found violations in 12 of the 14 usability principles and promote use of this method in practice to systematically identify usability problems. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Impact of an electronic alert notification system embedded in radiologists' workflow on closed-loop communication of critical results: a time series analysis.

    PubMed

    Lacson, Ronilda; O'Connor, Stacy D; Sahni, V Anik; Roy, Christopher; Dalal, Anuj; Desai, Sonali; Khorasani, Ramin

    2016-07-01

    Optimal critical test result communication is a Joint Commission national patient safety goal and requires documentation of closed-loop communication among care providers in the medical record. Electronic alert notification systems can facilitate an auditable process for creating alerts for transmission and acknowledgement of critical test results. We evaluated the impact of a patient safety initiative with an alert notification system on reducing critical results lacking documented communication, and assessed potential overuse of the alerting system for communicating results. We implemented an alert notification system-Alert Notification of Critical Results (ANCR)-in January 2010. We reviewed radiology reports finalised in 2009-2014 which lacked documented communication between the radiologist and another care provider, and assessed the impact of ANCR on the proportion of such reports with critical findings, using trend analysis over 10 semiannual time periods. To evaluate potential overuse of ANCR, we assessed the proportion of reports with non-critical results among provider-communicated reports. The proportion of reports with critical results among reports without documented communication decreased significantly over 4 years (2009-2014) from 0.19 to 0.05 (p<0.0001, Cochran-Armitage trend test). The proportion of provider-communicated reports with non-critical results remained unchanged over time before and after ANCR implementation (0.20 to 0.15, p=0.45, Cochran-Armitage trend test). A patient safety initiative with an alert notification system reduced the proportion of critical results among reports lacking documented communication between care providers. We observed no change in documented communication of non-critical results, suggesting the system did not promote overuse. Future studies are needed to evaluate whether such systems prevent subsequent patient harm. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System

    PubMed Central

    Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.

    2010-01-01

    Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845

  5. Experimental evaluation of candidate graphical microburst alert displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig R.; Hansman, R. John

    1992-01-01

    A piloted flight simulator experiment was conducted to evaluate issues related to the display of microburst alerts on electronic cockpit instrumentation. Issues addressed include display clarity, usefulness of multilevel microburst intensity information, and whether information from multiple sensors should be presented separately or 'fused' into combined alerts. Nine active airline pilots of 'glass cockpit' aircraft participated in the study. Microburst alerts presented on a moving map display were found to be visually clear and useful to pilots. Also, multilevel intensity information coded by colors or patterns was found to be important for decision making purposes. Pilot opinion was mixed on whether to 'fuse' data from multiple sensors, and some resulting design tradeoffs were identified. The positional information included in the graphical alert presentation was found useful by the pilots for planning lateral missed approach maneuvers, but may result in deviations which could interfere with normal airport operations. A number of flight crew training issues were also identified.

  6. Real Time Alert System: A Disease Management System Leveraging Health Information Exchange

    PubMed Central

    Anand, Vibha; Sheley, Meena E.; Xu, Shawn; Downs, Stephen M.

    2012-01-01

    Background Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Methods: Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA’s performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Results: Our results show that RTA was successfully able to deliver “just in time” patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. Conclusions: We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient’s asthma related emergency room admission so further follow up can happen in near real time. PMID:23569648

  7. Practitioners’ Views on Computerized Drug–Drug Interaction Alerts in the VA System

    PubMed Central

    Ko, Yu; Abarca, Jacob; Malone, Daniel C.; Dare, Donna C.; Geraets, Doug; Houranieh, Antoun; Jones, William N.; Nichol, W. Paul; Schepers, Gregory P.; Wilhardt, Michelle

    2007-01-01

    Objectives To assess Veterans Affairs (VA) prescribers’ and pharmacists’ opinions about computer-generated drug–drug interaction (DDI) alerts and obtain suggestions for improving DDI alerts. Design A mail survey of 725 prescribers and 142 pharmacists from seven VA medical centers across the United States. Measurements A questionnaire asked respondents about their sources of drug and DDI information, satisfaction with the combined inpatient and outpatient computerized prescriber order entry (CPOE) system, attitude toward DDI alerts, and suggestions for improving DDI alerts. Results The overall response rate was 40% (prescribers: 36%; pharmacists: 59%). Both prescribers and pharmacists indicated that the CPOE system had a neutral to positive impact on their jobs. DDI alerts were not viewed as a waste of time and the majority (61%) of prescribers felt that DDI alerts had increased their potential to prescribe safely. However, only 30% of prescribers felt DDI alerts provided them with what they needed most of the time. Both prescribers and pharmacists agreed that DDI alerts should be accompanied by management alternatives (73% and 82%, respectively) and more detailed information (65% and 89%, respectively). When asked about suggestions for improving DDI alerts, prescribers most preferred including management options whereas pharmacists most preferred making it more difficult to override lethal interactions. Prescribers and pharmacists reported primarily relying on electronic references for general drug information (62% and 55%, respectively) and DDI information (51% and 79%, respectively). Conclusion Respondents reported neutral to positive views regarding the effect of CPOE on their jobs. Their opinions suggest DDI alerts are useful but still require additional work to increase their clinical utility. PMID:17068346

  8. Comparative Analysis of ACAS-Xu and DAIDALUS Detect-and-Avoid Systems

    NASA Technical Reports Server (NTRS)

    Davies, Jason T.; Wu, Minghong G.

    2018-01-01

    The Detect and Avoid (DAA) capability of a recent version (Run 3) of the Airborne Collision Avoidance System-Xu (ACAS-Xu) is measured against that of the Detect and AvoID Alerting Logic for Unmanned Systems (DAIDALUS), a reference algorithm for the Phase 1 Minimum Operational Performance Standards (MOPS) for DAA. This comparative analysis of the two systems' alerting and horizontal guidance outcomes is conducted through the lens of the Detect and Avoid mission using flight data of scripted encounters from a recent flight test. Results indicate comparable timelines and outcomes between ACAS-Xu's Remain Well Clear alert and guidance and DAIDALUS's corrective alert and guidance, although ACAS-Xu's guidance appears to be more conservative. ACAS-Xu's Collision Avoidance alert and guidance occurs later than DAIDALUS's warning alert and guidance, and overlaps with DAIDALUS's timeline of maneuver to remain Well Clear. Interesting discrepancies between ACAS-Xu's directive guidance and DAIDALUS's "Regain Well Clear" guidance occur in some scenarios.

  9. Alerts in electronic medical records to promote a colorectal cancer screening programme: a cluster randomised controlled trial in primary care

    PubMed Central

    Guiriguet, Carolina; Muñoz-Ortiz, Laura; Burón, Andrea; Rivero, Irene; Grau, Jaume; Vela-Vallespín, Carmen; Vilarrubí, Mercedes; Torres, Miquel; Hernández, Cristina; Méndez-Boo, Leonardo; Toràn, Pere; Caballeria, Llorenç; Macià, Francesc; Castells, Antoni

    2016-01-01

    Background Participation rates in colorectal cancer screening are below recommended European targets. Aim To evaluate the effectiveness of an alert in primary care electronic medical records (EMRs) to increase individuals’ participation in an organised, population-based colorectal cancer screening programme when compared with usual care. Design and setting Cluster randomised controlled trial in primary care centres of Barcelona, Spain. Method Participants were males and females aged 50–69 years, who were invited to the first round of a screening programme based on the faecal immunochemical test (FIT) (n = 41 042), and their primary care professional. The randomisation unit was the physician cluster (n = 130) and patients were blinded to the study group. The control group followed usual care as per the colorectal cancer screening programme. In the intervention group, as well as usual care, an alert to health professionals (cluster level) to promote screening was introduced in the individual’s primary care EMR for 1 year. The main outcome was colorectal cancer screening participation at individual participant level. Results In total, 67 physicians and 21 619 patients (intervention group) and 63 physicians and 19 423 patients (control group) were randomised. In the intention-to-treat analysis screening participation was 44.1% and 42.2% respectively (odds ratio 1.08, 95% confidence interval [CI] = 0.97 to 1.20, P = 0.146). However, in the per-protocol analysis screening uptake in the intervention group showed a statistically significant increase, after adjusting for potential confounders (OR, 1.11; 95% CI = 1.02 to 1.22; P = 0.018). Conclusion The use of an alert in an individual’s primary care EMR is associated with a statistically significant increased uptake of an organised, FIT-based colorectal cancer screening programme in patients attending primary care centres. PMID:27266861

  10. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    NASA Astrophysics Data System (ADS)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  11. Evaluation of prescriber responses to pharmacogenomics clinical decision support for thiopurine S-methyltransferase testing.

    PubMed

    Ubanyionwu, Samuel; Formea, Christine M; Anderson, Benjamin; Wix, Kelly; Dierkhising, Ross; Caraballo, Pedro J

    2018-02-15

    Results of a study of prescribers' responses to a pharmacogenomics-based clinical decision support (CDS) alert designed to prompt thiopurine S -methyltransferase (TPMT) status testing are reported. A single-center, retrospective, chart review-based study was conducted to evaluate prescriber compliance with a pretest CDS alert that warned of potential thiopurine drug toxicity resulting from deficient TPMT activity due to TPMT gene polymorphism. The CDS alert was triggered when prescribers ordered thiopurine drugs for patients whose records did not indicate TPMT status or when historical thiopurine use was documented in the electronic health record. The alert pop-up also provided a link to online educational resources to guide thiopurine dosing calculations. During the 9-month study period, 500 CDS alerts were generated: in 101 cases (20%), TPMT phenotyping or TPMT genotyping was ordered; in 399 cases (80%), testing was not ordered. Multivariable regression analysis indicated that documentation of historical thiopurine use was the only independent predictor of test ordering. Among the 99 patients tested subsequent to CDS alerts, 70 (71%) had normal TPMT activity, 29 (29%) had intermediate activity, and none had deficient activity. The online resources provided thiopurine dosing recommendations applicable to 24 patients, but only 3 were prescribed guideline-supported doses after CDS alerts. The pretest CDS rule resulted in a large proportion of neglected alerts due to poor alerting accuracy and consequent alert fatigue. Prescriber usage of online thiopurine dosing resources was low. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  12. Collaborative knowledge acquisition for the design of context-aware alert systems.

    PubMed

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L; Bernstam, Elmer Victor

    2012-01-01

    To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Five internal medicine residents reviewed 18 anemia alerts, while 'talking aloud'. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules.

  13. Maintained effectiveness of an electronic alert system to prevent venous thromboembolism among hospitalized patients.

    PubMed

    Lecumberri, Ramón; Marqués, Margarita; Díaz-Navarlaz, María Teresa; Panizo, Elena; Toledo, Jon; García-Mouriz, Alberto; Páramo, José A

    2008-10-01

    Despite current guidelines, venous thromboembolism (VTE) prophylaxis is underused. Computerized programs to encourage physicians to apply thromboprophylaxis have been shown to be effective in selected populations. Our aim was to analyze the impact of the implementation of a computer-alert system for VTE risk in all hospitalized patients of a teaching hospital. A computer program linked to the clinical record database was developed to assess all hospitalized patients' VTE risk daily. The physician responsible for patients at high risk was alerted, but remained free to order or withhold prophylaxis. Over 19,000 hospitalized, medical and surgical, adult patients between January to June 2005 (pre-intervention phase), January to June 2006 and January to June 2007 (post-intervention phase), were included. During the first semesters of 2006 and 2007, an electronic alert was sent to 32.8% and 32.2% of all hospitalized patients, respectively. Appropriate prophylaxis among alerted patients was ordered in 89.7% (2006) and 88.5% (2007) of surgical patients, and in 49.2% (2006) and 64.4% (2007) of medical patients. A sustained reduction of VTE during hospitalization was achieved, Odds ratio (OR): 0.53, 95% confidence interval (CI) (0.25-1.10) and OR: 0.51, 95%CI (0.24-1.05) during the first semesters of 2006 and 2007 respectively, the impact being significant (p < 0.05) among medical patients in 2007, OR: 0.36, 95%CI (0.12-0.98). The implementation of a computer-alert program helps physicians to assess each patient's thrombotic risk, leading to a better use of thromboprophylaxis, and a reduction in the incidence of VTE among hospitalized patients. For the first time, an intervention aimed to improve VTE prophylaxis shows maintained effectiveness over time.

  14. Development and use of active clinical decision support for preemptive pharmacogenomics

    PubMed Central

    Bell, Gillian C; Crews, Kristine R; Wilkinson, Mark R; Haidar, Cyrine E; Hicks, J Kevin; Baker, Donald K; Kornegay, Nancy M; Yang, Wenjian; Cross, Shane J; Howard, Scott C; Freimuth, Robert R; Evans, William E; Broeckel, Ulrich; Relling, Mary V; Hoffman, James M

    2014-01-01

    Background Active clinical decision support (CDS) delivered through an electronic health record (EHR) facilitates gene-based drug prescribing and other applications of genomics to patient care. Objective We describe the development, implementation, and evaluation of active CDS for multiple pharmacogenetic test results reported preemptively. Materials and methods Clinical pharmacogenetic test results accompanied by clinical interpretations are placed into the patient's EHR, typically before a relevant drug is prescribed. Problem list entries created for high-risk phenotypes provide an unambiguous trigger for delivery of post-test alerts to clinicians when high-risk drugs are prescribed. In addition, pre-test alerts are issued if a very-high risk medication is prescribed (eg, a thiopurine), prior to the appropriate pharmacogenetic test result being entered into the EHR. Our CDS can be readily modified to incorporate new genes or high-risk drugs as they emerge. Results Through November 2012, 35 customized pharmacogenetic rules have been implemented, including rules for TPMT with azathioprine, thioguanine, and mercaptopurine, and for CYP2D6 with codeine, tramadol, amitriptyline, fluoxetine, and paroxetine. Between May 2011 and November 2012, the pre-test alerts were electronically issued 1106 times (76 for thiopurines and 1030 for drugs metabolized by CYP2D6), and the post-test alerts were issued 1552 times (1521 for TPMT and 31 for CYP2D6). Analysis of alert outcomes revealed that the interruptive CDS appropriately guided prescribing in 95% of patients for whom they were issued. Conclusions Our experience illustrates the feasibility of developing computational systems that provide clinicians with actionable alerts for gene-based drug prescribing at the point of care. PMID:23978487

  15. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    PubMed

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes must be continually analyzed and restructured to yield the intended full benefits of BCMA technology. © 2011 SAGE Publications.

  16. Do Family Physicians Retrieve Synopses of Clinical Research Previously Read as Email Alerts?

    PubMed Central

    Pluye, Pierre; Johnson-Lafleur, Janique; Granikov, Vera; Shulha, Michael; Bartlett, Gillian; Marlow, Bernard

    2011-01-01

    Background A synopsis of new clinical research highlights important aspects of one study in a brief structured format. When delivered as email alerts, synopses enable clinicians to become aware of new developments relevant for practice. Once read, a synopsis can become a known item of clinical information. In time-pressured situations, remembering a known item may facilitate information retrieval by the clinician. However, exactly how synopses first delivered as email alerts influence retrieval at some later time is not known. Objectives We examined searches for clinical information in which a synopsis previously read as an email alert was retrieved (defined as a dyad). Our study objectives were to (1) examine whether family physicians retrieved synopses they previously read as email alerts and then to (2) explore whether family physicians purposefully retrieved these synopses. Methods We conducted a mixed-methods study in which a qualitative multiple case study explored the retrieval of email alerts within a prospective longitudinal cohort of practicing family physicians. Reading of research-based synopses was tracked in two contexts: (1) push, meaning to read on email and (2) pull, meaning to read after retrieval from one electronic knowledge resource. Dyads, defined as synopses first read as email alerts and subsequently retrieved in a search of a knowledge resource, were prospectively identified. Participants were interviewed about all of their dyads. Outcomes were the total number of dyads and their type. Results Over a period of 341 days, 194 unique synopses delivered to 41 participants resulted in 4937 synopsis readings. In all, 1205 synopses were retrieved over an average of 320 days. Of the 1205 retrieved synopses, 21 (1.7%) were dyads made by 17 family physicians. Of the 1205 retrieved synopses, 6 (0.5%) were known item type dyads. However, dyads also occurred serendipitously. Conclusion In the single knowledge resource we studied, email alerts containing research-based synopses were rarely retrieved. Our findings help us to better understand the effect of push on pull and to improve the integration of research-based information within electronic resources for clinicians. PMID:22130465

  17. Do family physicians retrieve synopses of clinical research previously read as email alerts?

    PubMed

    Grad, Roland; Pluye, Pierre; Johnson-Lafleur, Janique; Granikov, Vera; Shulha, Michael; Bartlett, Gillian; Marlow, Bernard

    2011-11-30

    A synopsis of new clinical research highlights important aspects of one study in a brief structured format. When delivered as email alerts, synopses enable clinicians to become aware of new developments relevant for practice. Once read, a synopsis can become a known item of clinical information. In time-pressured situations, remembering a known item may facilitate information retrieval by the clinician. However, exactly how synopses first delivered as email alerts influence retrieval at some later time is not known. We examined searches for clinical information in which a synopsis previously read as an email alert was retrieved (defined as a dyad). Our study objectives were to (1) examine whether family physicians retrieved synopses they previously read as email alerts and then to (2) explore whether family physicians purposefully retrieved these synopses. We conducted a mixed-methods study in which a qualitative multiple case study explored the retrieval of email alerts within a prospective longitudinal cohort of practicing family physicians. Reading of research-based synopses was tracked in two contexts: (1) push, meaning to read on email and (2) pull, meaning to read after retrieval from one electronic knowledge resource. Dyads, defined as synopses first read as email alerts and subsequently retrieved in a search of a knowledge resource, were prospectively identified. Participants were interviewed about all of their dyads. Outcomes were the total number of dyads and their type. Over a period of 341 days, 194 unique synopses delivered to 41 participants resulted in 4937 synopsis readings. In all, 1205 synopses were retrieved over an average of 320 days. Of the 1205 retrieved synopses, 21 (1.7%) were dyads made by 17 family physicians. Of the 1205 retrieved synopses, 6 (0.5%) were known item type dyads. However, dyads also occurred serendipitously. In the single knowledge resource we studied, email alerts containing research-based synopses were rarely retrieved. Our findings help us to better understand the effect of push on pull and to improve the integration of research-based information within electronic resources for clinicians.

  18. How Regrouping Alerts in Computerized Physician Order Entry Layout Influences Physicians' Prescription Behavior: Results of a Crossover Randomized Trial.

    PubMed

    Wipfli, Rolf; Ehrler, Frederic; Bediang, Georges; Bétrancourt, Mireille; Lovis, Christian

    2016-06-02

    As demonstrated in several publications, low positive predictive value alerts in computerized physician order entry (CPOE) induce fatigue and may interrupt physicians unnecessarily during prescription of medication. Although it is difficult to increase the consideration of medical alerts by physician through an improvement of their predictive value, another approach consists to act on the way they are presented. The interruption management model inspired us to propose an alternative alert display strategy of regrouping the alerts in the screen layout, as a possible solution for reducing the interruption in physicians' workflow. In this study, we compared 2 CPOE designs based on a particular alert presentation strategy: one design involved regrouping the alerts in a single place on the screen, and in the other, the alerts were located next to the triggering information. Our objective was to evaluate experimentally whether the new design led to fewer interruptions in workflow and if it affected alert handling. The 2 CPOE designs were compared in a controlled crossover randomized trial. All interactions with the system and eye movements were stored for quantitative analysis. The study involved a group of 22 users consisting of physicians and medical students who solved medical scenarios containing prescription tasks. Scenario completion time was shorter when the alerts were regrouped (mean 117.29 seconds, SD 36.68) than when disseminated on the screen (mean 145.58 seconds, SD 75.07; P=.045). Eye tracking revealed that physicians fixated longer on alerts in the classic design (mean 119.71 seconds, SD 76.77) than in the centralized alert design (mean 70.58 seconds, SD 33.53; P=.001). Visual switches between prescription and alert areas, indicating interruption, were reduced with centralized alerts (mean 41.29, SD 21.26) compared with the classic design (mean 57.81, SD 35.97; P=.04). Prescription behavior (ie, prescription changes after alerting), however, did not change significantly between the 2 strategies of display. The After-Scenario Questionnaire (ASQ) that was filled out after each scenario showed that overall satisfaction was significantly rated lower when alerts were regrouped (mean 4.37, SD 1.23) than when displayed next to the triggering information (mean 5.32, SD 0.94; P=.02). Centralization of alerts in a table might be a way to motivate physicians to manage alerts more actively, in a meaningful way, rather than just being interrupted by them. Our study could not provide clear recommendations yet, but provides objective data through a cognitive psychological approach. Future tests should work on standardized scenarios that would enable to not only measure physicians' behavior (visual fixations and handling of alerts) but also validate those actions using clinical criteria.

  19. Method and apparatus for extraction of low-frequency artifacts from brain waves for alertness detection

    DOEpatents

    Clapp, Ned E.; Hively, Lee M.

    1997-01-01

    Methods and apparatus automatically detect alertness in humans by monitoring and analyzing brain wave signals. Steps include: acquiring the brain wave (EEG or MEG) data from the subject, digitizing the data, separating artifact data from raw data, and comparing trends in f-data to alertness indicators, providing notification of inadequate alertness.

  20. Automated quality checks on repeat prescribing.

    PubMed Central

    Rogers, Jeremy E; Wroe, Christopher J; Roberts, Angus; Swallow, Angela; Stables, David; Cantrill, Judith A; Rector, Alan L

    2003-01-01

    BACKGROUND: Good clinical practice in primary care includes periodic review of repeat prescriptions. Markers of prescriptions that may need review have been described, but manually checking all repeat prescriptions against the markers would be impractical. AIM: To investigate the feasibility of computerising the application of repeat prescribing quality checks to electronic patient records in United Kingdom (UK) primary care. DESIGN OF STUDY: Software performance test against benchmark manual analysis of cross-sectional convenience sample of prescribing documentation. SETTING: Three general practices in Greater Manchester, in the north west of England, during a 4-month period in 2001. METHOD: A machine-readable drug information resource, based on the British National Formulary (BNF) as the 'gold standard' for valid drug indications, was installed in three practices. Software raised alerts for each repeat prescribed item where the electronic patient record contained no valid indication for the medication. Alerts raised by the software in two practices were analysed manually. Clinical reaction to the software was assessed by semi-structured interviews in three practices. RESULTS: There was no valid indication in the electronic medical records for 14.8% of repeat prescribed items. Sixty-two per cent of all alerts generated were incorrect. Forty-three per cent of all incorrect alerts were as a result of errors in the drug information resource, 44% to locally idiosyncratic clinical coding, 8% to the use of the BNF without adaptation as a gold standard, and 5% to the inability of the system to infer diagnoses that, although unrecorded, would be 'obvious' to a clinical reading the record. The interviewed clinicians supported the goals of the software. CONCLUSION: Using electronic records for secondary decision support purposes will benefit from (and may require) both more consistent electronic clinical data collection across multiple sites, and reconciling clinicians' willingness to infer unstated but 'obvious' diagnoses with the machine's inability to do the same. PMID:14702902

  1. Simultaneous transcranial magnetic stimulation and single neuron recording in alert non-human primates

    PubMed Central

    Mueller, Jerel K.; Grigsby, Erinn M.; Prevosto, Vincent; Petraglia, Frank W.; Rao, Hrishikesh; Deng, Zhi-De; Peterchev, Angel V.; Sommer, Marc A.; Egner, Tobias; Platt, Michael L.; Grill, Warren M.

    2014-01-01

    Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report novel methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally perturbed by stimulation artifact in intact, awake monkeys (Macaca mulatta). We recorded action potentials within ~1 ms after 0.4 ms TMS pulses and observed changes in activity that differed significantly for active stimulation as compared to sham stimulation. The methodology is compatible with standard equipment in primate laboratories, allowing for easy implementation. Application of these new tools will facilitate the refinement of next generation TMS devices, experiments, and treatment protocols. PMID:24974797

  2. An MFC-Based Online Monitoring and Alert System for Activated Sludge Process

    PubMed Central

    Xu, Gui-Hua; Wang, Yun-Kun; Sheng, Guo-Ping; Mu, Yang; Yu, Han-Qing

    2014-01-01

    In this study, based on a simple, compact and submersible microbial fuel cell (MFC), a novel online monitoring and alert system with self-diagnosis function was established for the activated sludge (AS) process. Such a submersible MFC utilized organic substrates and oxygen in the AS reactor as the electron donor and acceptor respectively, and could provide an evaluation on the status of the AS reactor and thus give a reliable early warning of potential risks. In order to evaluate the reliability and sensitivity of this online monitoring and alert system, a series of tests were conducted to examine the response of this system to various shocks imposed on the AS reactor. The results indicate that this online monitoring and alert system was highly sensitive to the performance variations of the AS reactor. The stability, sensitivity and repeatability of this online system provide feasibility of being incorporated into current control systems of wastewater treatment plants to real-time monitor, diagnose, alert and control the AS process. PMID:25345502

  3. Wireless clinical alerts and patient outcomes in the surgical intensive care unit.

    PubMed

    Major, Kevin; Shabot, M Michael; Cunneen, Scott

    2002-12-01

    Errors in medicine have gained public interest since the Institute of Medicine published its 1999 report on this subject. Although errors of commission are frequently cited, errors of omission can be equally serious. A computerized surgical intensive care unit (SICU) information system when coupled to an event-driven alerting engine has the potential to reduce errors of omission for critical intensive care unit events. Automated alerts and patient outcomes were prospectively collected for all patients admitted to a tertiary-care SICU for a 2-year period. During the study period 3,973 patients were admitted to the SICU and received 13,608 days of care. A total of 15,066 alert pages were sent including alerts for physiologic condition (6,163), laboratory data (4,951), blood gas (3,774), drug allergy (130), and toxic drug levels (48). Admission Simplified Acute Physiology Score and Acute Physiology and Chronic Health Evaluation II score, SICU lengths of stay, and overall mortality rates were significantly higher in patients who triggered the alerting system. Patients triggering the alert paging system were 49.4 times more likely to die in the SICU compared with patients who did not generate an alert. Even after transfer to floor care the patients who triggered the alerting system were 5.7 times more likely to die in the hospital. An alert page identifies patients who will stay in the SICU longer and have a significantly higher chance of death compared with patients who do not trigger the alerting system.

  4. Electronic search and rescue aids

    NASA Technical Reports Server (NTRS)

    Trudell, B. J.

    1980-01-01

    There are two elements to the basic electronic search and rescue problem: a means for immediately alerting potential rescuers and an effective method to guide the rescue forces to the scene of the emergency. An Emergency Locator Transmitter (ELT) used by aircraft or an Emergency Position Indicating Radio Beacon (EPIRB) used by maritime vessels has the capability of providing for both an immediate alert and a homing signal to assist rescue forces in locating the site of the distress. This paper describes the development of ELT/EPIRB systems. Emphasis is placed on the SARSAT project, the COSPAS/SARSAT project, and an experimental 406 MHz ELT/EPIRB system.

  5. Method and apparatus for extraction of low-frequency artifacts from brain waves for alertness detection

    DOEpatents

    Clapp, N.E.; Hively, L.M.

    1997-05-06

    Methods and apparatus automatically detect alertness in humans by monitoring and analyzing brain wave signals. Steps include: acquiring the brain wave (EEG or MEG) data from the subject, digitizing the data, separating artifact data from raw data, and comparing trends in f-data to alertness indicators, providing notification of inadequate alertness. 4 figs.

  6. Impact of Homeland Security Alert level on calls to a law enforcement peer support hotline.

    PubMed

    Omer, Saad B; Barnett, Daniel J; Castellano, Cherie; Wierzba, Rachel K; Hiremath, Girish S; Balicer, Ran D; Everly, George S

    2007-01-01

    The Homeland Security Advisory System (HSAS) was established by the Department of Homeland Security to communicate the risk of a terrorist event. In order to explore the potential psychological impacts of HSAS we analyzed the effects of terror alerts on the law enforcement community. We used data from the New Jersey Cop 2 Cop crisis intervention hotline. Incidence Rate Ratios--interpreted as average relative increases in the daily number of calls to the Cop 2 Cop hotline during an increased alert period--were computed from Poisson models. The hotline received a total of 4,145 initial calls during the study period. The mean daily number of calls was higher during alert level elevation compared to prior 7 days (7.68 vs. 8.00). In the Poisson regression analysis, the Incidence Rate Ratios of number of calls received during elevated alert levels compared to the reference period of seven days preceding each change in alert were close to 1, with confidence intervals crossing 1 (i.e. not statistically significant) for all lag periods evaluated. This investigation, in the context of New Jersey law enforcement personnel, does not support the concern that elevating the alert status places undue stress upon alert recipients.

  7. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.« less

  8. Collaborative knowledge acquisition for the design of context-aware alert systems

    PubMed Central

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L

    2012-01-01

    Objective To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Materials and Methods Five internal medicine residents reviewed 18 anemia alerts, while ‘talking aloud’. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. Results The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). Discussion It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Conclusion Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules. PMID:22744961

  9. Comparison of warfarin therapy clinical outcomes following implementation of an automated mobile phone-based critical laboratory value text alert system.

    PubMed

    Lin, Shu-Wen; Kang, Wen-Yi; Lin, Dong-Tsamn; Lee, James; Wu, Fe-Lin; Chen, Chuen-Liang; Tseng, Yufeng J

    2014-01-01

    Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time was detected for junior physicians. Implementation of an automated PHS-based text alert system did not adversely impact clinical or safety outcomes of patients on warfarin therapy. Approximately 80% immediate recognition of text alerts was achieved. The potential benefits of an automated PHS alert for senior physicians were demonstrated.

  10. Reducing duplicate testing: a comparison of two clinical decision support tools.

    PubMed

    Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert

    2015-05-01

    Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.

  11. Advantages and Disadvantages of Educational Email Alerts for Family Physicians: Viewpoint

    PubMed Central

    Badran, Hani; Grad, Roland

    2015-01-01

    Background Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. Objective The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians’ knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants’ suggestions to improve email alert services for CME. Methods We conducted a qualitative descriptive study using the “Knowledge, Attitude, Behavior” model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. Results All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. Conclusions The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts. PMID:25803184

  12. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    PubMed

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; p<0.001). The total financial saving of test withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Advantages and disadvantages of educational email alerts for family physicians: viewpoint.

    PubMed

    Badran, Hani; Pluye, Pierre; Grad, Roland

    2015-02-27

    Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians' knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants' suggestions to improve email alert services for CME. We conducted a qualitative descriptive study using the "Knowledge, Attitude, Behavior" model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts.

  14. A framework for evaluating the appropriateness of clinical decision support alerts and responses

    PubMed Central

    Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F

    2011-01-01

    Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334

  15. Clinical decision support alert malfunctions: analysis and empirically derived taxonomy.

    PubMed

    Wright, Adam; Ai, Angela; Ash, Joan; Wiesen, Jane F; Hickman, Thu-Trang T; Aaron, Skye; McEvoy, Dustin; Borkowsky, Shane; Dissanayake, Pavithra I; Embi, Peter; Galanter, William; Harper, Jeremy; Kassakian, Steve Z; Ramoni, Rachel; Schreiber, Richard; Sirajuddin, Anwar; Bates, David W; Sittig, Dean F

    2018-05-01

    To develop an empirically derived taxonomy of clinical decision support (CDS) alert malfunctions. We identified CDS alert malfunctions using a mix of qualitative and quantitative methods: (1) site visits with interviews of chief medical informatics officers, CDS developers, clinical leaders, and CDS end users; (2) surveys of chief medical informatics officers; (3) analysis of CDS firing rates; and (4) analysis of CDS overrides. We used a multi-round, manual, iterative card sort to develop a multi-axial, empirically derived taxonomy of CDS malfunctions. We analyzed 68 CDS alert malfunction cases from 14 sites across the United States with diverse electronic health record systems. Four primary axes emerged: the cause of the malfunction, its mode of discovery, when it began, and how it affected rule firing. Build errors, conceptualization errors, and the introduction of new concepts or terms were the most frequent causes. User reports were the predominant mode of discovery. Many malfunctions within our database caused rules to fire for patients for whom they should not have (false positives), but the reverse (false negatives) was also common. Across organizations and electronic health record systems, similar malfunction patterns recurred. Challenges included updates to code sets and values, software issues at the time of system upgrades, difficulties with migration of CDS content between computing environments, and the challenge of correctly conceptualizing and building CDS. CDS alert malfunctions are frequent. The empirically derived taxonomy formalizes the common recurring issues that cause these malfunctions, helping CDS developers anticipate and prevent CDS malfunctions before they occur or detect and resolve them expediently.

  16. Development of a SNOMED CT based national medication decision support system.

    PubMed

    Greibe, Kell

    2013-01-01

    Physicians often lack the time to familiarize themselves with the details of particular allergies or other drug restrictions. Clinical Decision Support (CDS), based on a structured terminology as SNOMED CT (SCT), can help physicians get an overview, by automatically alerting allergy, interactions and other important information. The centralized CDS platform based on SCT, controls Allergy, Interactions, Risk Situation Drugs and Max Dose restrictions by the help of databases developed for these specific purposes. The CDS will respond to automatic web service requests from the hospital or GP electronic medication system (EMS) during prescription, and return alerts and information. The CDS also contains a Physicians Preference Database where the physicians individually can set which kind of alerts they want to see. The result is clinically useful information physicians can use as a base for a more effective and safer treatment, without developing alert fatigue.

  17. Diversion Alert: 1-Year Evaluation Across Northern New England, 2013–2014

    PubMed Central

    Desrosiers, Clare

    2016-01-01

    This report describes Diversion Alert, a unique online tool aimed at reducing misuse and diversion of prescription drugs, and reports the results of a 1-year evaluation of Diversion Alert’s impact in Maine. We used a quasi-experimental research design to compare survey data in Maine with those of neighboring states (New Hampshire and Vermont, 2013 and 2014). Compared with their counterparts in New Hampshire and Vermont who did not use Diversion Alert, prescribers and pharmacists in Maine who used Diversion Alert increased their communication with patients and other providers involved in their patients’ care, became aware of patients arrested for prescription drugs possession or diversion, used best practices associated with prevention or detection of addiction and diversion more frequently, and attributed positive changes in their prescribing practices to Diversion Alert. In combination with other state and federal programs, Diversion Alert may be an effective tool to help prevent the misuse of opioid medications. PMID:27880633

  18. Rule base system for identification of patients with specific critical care syndromes: The "sniffer" for acute lung injury.

    PubMed

    Herasevich, V; Yilmaz, M; Khan, H; Chute, C G; Gajic, O

    2007-10-11

    Early detection of specific critical care syndromes, such as sepsis or acute lung injury (ALI)is essential for timely implementation of evidence based therapies. Using a near-real time copy of the electronic medical records ("ICU data mart") we developed and validated custom electronic alert (ALI"sniffer") in a cohort of 485 critically ill medical patients. Compared with the gold standard of prospective screening, ALI "sniffer" demonstrated good sensitivity, 93% (95% CI 90 to 95) and specificity, 90% (95% CI 87 to 92). It is not known if the bedside implementation of ALI "sniffer" will improve the adherence to evidence-based therapies and outcome of patients with ALI.

  19. Sensory Overload and Technology in Critical Care.

    PubMed

    Wung, Shu-Fen; Malone, Daniel C; Szalacha, Laura

    2018-06-01

    In this focus group study, we identified issues associated with sensory overload from medical technology alarms/alerts for intensive care unit nurses. Participants indicated that alarms from cardiopulmonary monitors, ventilators, and intravenous pumps contributed the most to sensory overload and, yet, these alarms were also deemed the most helpful. Alerts/alarms from electronic health records and medication dispensing systems were rated low in contributing to sensory overload, as well as being the least helpful. Specific device/technology barriers, related to device alerts/alarms, are detailed. Future user-centered and integrated improvements in alarm systems associated with medical devices in the intensive care unit are needed. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates.

    PubMed

    McDonald, C P; Rogers, A; Cox, M; Smith, R; Roy, A; Robbins, S; Hartley, S; Barbara, J A J; Rothenberg, S; Stutzman, L; Widders, G

    2002-10-01

    Bacterial transmission remains the major component of morbidity and mortality associated with transfusion-transmitted infections. Platelet concentrates are the most common cause of bacterial transmission. The BacT/ALERT 3D automated blood culture system has the potential to screen platelet concentrates for the presence of bacteria. Evaluation of this system was performed by spiking day 2 apheresis platelet units with individual bacterial isolates at final concentrations of 10 and 100 colony-forming units (cfu) mL-1. Fifteen organisms were used which had been cited in platelet transmission and monitoring studies. BacT/ALERT times to detection were compared with thioglycollate broth cultures, and the performance of five types of BacT/ALERT culture bottles was evaluated. Sampling was performed immediately after the inoculation of the units, and 10 replicates were performed per organism concentration for each of the five types of BacT/ALERT bottles. The mean times for the detection of these 15 organisms by BacT/ALERT, with the exception of Propionibacterium acnes, ranged from 9.1 to 48.1 h (all 10 replicates were positive). In comparison, the time range found using thioglycollate was 12.0-32.3 h (all 10 replicates were positive). P. acnes' BacT/ALERT mean detection times ranged from 89.0 to 177.6 h compared with 75.6-86.4 h for the thioglycollate broth. BacT/ALERT, with the exception of P. acnes, which has dubious clinical significance, gave equivalent or shorter detection times when compared with the thioglycollate broth system. The BacT/ALERT system detected a range of organisms at levels of 10 and 100 cfu mL-1. This study validates the BacT/ALERT microbial detection system for screening platelets. Currently, the system is the only practically viable option available for routinely screening platelet concentrates to prevent bacterial transmission.

  1. Library information services.

    NASA Astrophysics Data System (ADS)

    Michold, U.; Cummins, M.; Watson, J. M.; Holmquist, J.; Shobbrook, R.

    Contents: library catalogs and holdings; indexing and abstract services; preprint services; electronic journals and newsletters; alerting services; commercial databases; informal networking; use of a thesaurus for on-line searching. An extensive list of access pointers for library catalogs and services, electronic newsletters, and publishers and bookshops is enclosed.

  2. Effects of in-vehicle monitoring on the driving behavior of teenagers.

    PubMed

    Farmer, Charles M; Kirley, Bevan B; McCartt, Anne T

    2010-02-01

    The objective was to determine if teenage driving behavior improves when a monitoring and feedback device is installed in the teen's vehicle. Vehicles of 85 teenage drivers were fit with a device that detected all instances of sudden braking/acceleration, speeding, and nonuse of seat belts. Drivers were assigned randomly to one of four research groups, differing in whether or not an alert sounded in the vehicle and whether or not parents were given access to websites containing notification records. Time trends in event rates per mile traveled were compared using Poisson regression. Seat belt use improved when violations were reported to the parent websites, and improved even more when in-vehicle alerts were activated. Consistent reductions in speeding were achieved only when teenagers received alerts about their speeding behavior, believed their speeding behavior would not be reported to parents if corrected, and when parents were being notified of such behavior by report cards. Electronic monitoring of teenage drivers can reduce the incidence of risky behavior, especially seat belt nonuse. More complicated behavior is more difficult to change, however. Parent participation is key to successful behavioral modification, but it is yet to be determined how best to encourage such participation. Copyright 2010 Elsevier Ltd. All rights reserved.

  3. Remote monitoring of Xpert® MTB/RIF testing in Mozambique: results of programmatic implementation of GxAlert.

    PubMed

    Cowan, J; Michel, C; Manhiça, I; Mutaquiha, C; Monivo, C; Saize, D; Beste, J; Creswell, J; Codlin, A J; Gloyd, S

    2016-03-01

    Electronic diagnostic tests, such as the Xpert® MTB/RIF assay, are being implemented in low- and middle-income countries (LMICs). However, timely information from these tests available via remote monitoring is underutilized. The failure to transmit real-time, actionable data to key individuals such as clinicians, patients, and national monitoring and evaluation teams may negatively impact patient care. To describe recently developed applications that allow for real-time, remote monitoring of Xpert results, and initial implementation of one of these products in central Mozambique. In partnership with the Mozambican National Tuberculosis Program, we compared three different remote monitoring tools for Xpert and selected one, GxAlert, to pilot and evaluate at five public health centers in Mozambique. GxAlert software was successfully installed on all five Xpert computers, and test results are now uploaded daily via a USB internet modem to a secure online database. A password-protected web-based interface allows real-time analysis of test results, and 1200 positive tests for tuberculosis generated 8000 SMS result notifications to key individuals. Remote monitoring of diagnostic platforms is feasible in LMICs. While promising, this effort needs to address issues around patient data ownership, confidentiality, interoperability, unique patient identifiers, and data security.

  4. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    PubMed Central

    Alagiakrishnan, Kannayiram; Wilson, Patricia; Sadowski, Cheryl A; Rolfson, Darryl; Ballermann, Mark; Ausford, Allen; Vermeer, Karla; Mohindra, Kunal; Romney, Jacques; Hayward, Robert S

    2016-01-01

    Background Elderly people (aged 65 years or more) are at increased risk of polypharmacy (five or more medications), inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS) within an electronic medical record (EMR) could improve medication safety. Methods Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR). The “Seniors Medication Alert and Review Technologies” (SMART) intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages) and active (order-entry alerts) prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed. Results Analysis of subjective data revealed that most clinicians agreed that CDS appeared at appropriate times during patient care. Although managing alerts incurred a modest time burden, most also agreed that workflow was not disrupted. Prevalent concerns related to clinician accountability and potential liability. Approximately 36% of eligible encounters triggered at least one SMART alert, with GFR alert, and most frequent medication warnings were with hypnotics and anticholinergics. Approximately 25% of alerts were overridden and ~15% elicited an evidence check. Conclusion While most SMART alerts validated clinician choices, they were received as valuable reminders for evidence-informed care and education. Data from this study may aid other attempts to implement Beers’ Criteria in ambulatory care EMRs. PMID:26869776

  5. What Do Context Aware Electronic Alerts from Virtual Learning Environments Tell Us about User Time & Location?

    ERIC Educational Resources Information Center

    Crane, Laura; Benachour, Phillip

    2013-01-01

    The paper describes the analysis of user location and time stamp information automatically logged when students receive and interact with electronic updates from the University's virtual learning environment. The electronic updates are sent to students' mobile devices using RSS feeds. The mobile reception of such information can be received in…

  6. Design and Evaluation of an Electronic Override Mechanism for Medication Alerts to Facilitate Communication Between Prescribers and Pharmacists.

    PubMed

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Saleem, Jason J; Weiner, Michael; Spina, Jeffrey R; Daggy, Joanne K; Zillich, Alan J

    2015-07-01

    Computerized medication alerts can often be bypassed by entering an override rationale, but prescribers' override reasons are frequently ambiguous to pharmacists who review orders. To develop and evaluate a new override mechanism for adverse reaction and drug-drug interaction alerts. We hypothesized that the new mechanism would improve usability for prescribers and increase the clinical appropriateness of override reasons. A counterbalanced, crossover study was conducted with 20 prescribers in a simulated prescribing environment. We modified the override mechanism timing, navigation, and text entry. Instead of free-text entry, the new mechanism presented prescribers with a predefined set of override reasons. We assessed usability (learnability, perceived efficiency, and usability errors) and used a priori criteria to evaluate the clinical appropriateness of override reasons entered. Prescribers rated the new mechanism as more efficient (Wilcoxon signed-rank test, P = 0.032). When first using the new design, 5 prescribers had difficulty finding the new mechanism, and 3 interpreted the navigation to mean that the alert could not be overridden. The number of appropriate override reasons significantly increased with the new mechanism compared with the original mechanism (median change of 3.0; interquartile range = 3.0; P < 0.0001). When prescribers were given a menu-based choice for override reasons, clinical appropriateness of these reasons significantly improved. Further enhancements are necessary, but this study is an important first step toward a more standardized menu of override choices. Findings may be used to improve communication through e-prescribing systems between prescribers and pharmacists. © The Author(s) 2015.

  7. Evaluation of a Novel System to Enhance Clinicians' Recognition of Preadmission Adverse Drug Reactions.

    PubMed

    Smith, Joshua C; Chen, Qingxia; Denny, Joshua C; Roden, Dan M; Johnson, Kevin B; Miller, Randolph A

    2018-04-01

     Often unrecognized by providers, adverse drug reactions (ADRs) diminish patients' quality of life, cause preventable admissions and emergency department visits, and increase health care costs.  This article evaluates whether an automated system, the Adverse Drug Effect Recognizer (ADER), could assist clinicians in detecting and addressing inpatients' ongoing preadmission ADRs.  ADER uses natural language processing to extract patients' medications, findings, and past diagnoses from admission notes. It compares excerpted information to a database of known medication adverse effects and promptly warns clinicians about potential ongoing ADRs and potential confounders via alerts placed in patients' electronic health records (EHRs). A 3-month intervention trial evaluated ADER's impact on antihypertensive medication ordering behaviors. At the time of patient admission, ADER warned providers on the Internal Medicine wards of Vanderbilt University Hospital about potential ongoing preadmission antihypertensive medication ADRs. A retrospective control group, comprised similar physicians from a period prior to the intervention, received no alerts. The evaluation compared ordering behaviors for each group to determine if preadmission medications changed during hospitalization or at discharge. The study also analyzed intervention group participants' survey responses and user comments.  ADER identified potential preadmission ADRs for 30% of both groups. Compared with controls, intervention providers more often withheld or discontinued suspected ADR-causing medications during the inpatient stay ( p  < 0.001). Intervention providers who responded to alert-related surveys held or discontinued suspected ADR-causing medications more often at discharge ( p  < 0.001).  Results indicate that ADER helped physicians recognize ADRs and reduced ordering of suspected ADR-causing medications. In hospitals using EHRs, ADER-like systems could improve clinicians' recognition and elimination of ongoing ADRs. Schattauer GmbH Stuttgart.

  8. Optimizing the real-time ground level enhancement alert system based on neutron monitor measurements: Introducing GLE Alert Plus

    NASA Astrophysics Data System (ADS)

    Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.

    2014-11-01

    Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.

  9. A prospective study of the feasibility and acceptability of a Web-based, electronic patient-reported outcome system in assessing patient recovery after major gynecologic cancer surgery.

    PubMed

    Andikyan, Vaagn; Rezk, Youssef; Einstein, M Heather; Gualtiere, Gina; Leitao, Mario M; Sonoda, Yukio; Abu-Rustum, Nadeem R; Barakat, Richard R; Basch, Ethan M; Chi, Dennis S

    2012-11-01

    The purposes of this study are to evaluate the feasibility of capturing patient-reported outcomes (PROs) electronically and to identify the most common distressing symptoms in women recovering from major gynecologic cancer surgery. This was a prospective, single-arm pilot study. Eligible participants included those scheduled for a laparotomy for presumed or known gynecologic malignancy. Patients completed a Web-based "STAR" (Symptom Tracking and Reporting for Patients) questionnaire once preoperatively and weekly during the 6-week postoperative period. The questionnaire consisted of the patient adaptation of the NCI CTCAE 3.0 and EORTC QLQ-C30 3.0. When a patient submitted a response that was concerning, an automated email alert was sent to the clinician. The patient's assessment of STAR's usefulness was measured via an exit survey. Forty-nine patients completed the study. The procedures included the following: hysterectomy±staging (67%), resection of tumor (22%), salpingo-oophorectomy (6%), and other (4%). Most patients (82%) completed at least 4 sessions in STAR. The CTC generated 43 alerts. These alerts resulted in 25 telephone contacts with patients, 2 ER referrals, one new appointment, and one pharmaceutical prescription. The 3 most common patient-reported symptoms generating an alert were as follows: poor performance status (19%), nausea (18%), and fatigue (17%). Most patients found STAR useful (80%) and would recommend it to others (85%). Application of a Web-based, electronic STAR system is feasible in the postoperative period, highly accepted by patients, and warrants further study. Poor performance status, nausea, and fatigue were the most common distressing patient-reported symptoms. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Technologic Distractions (Part 1): Summary of Approaches to Manage Alert Quantity With Intent to Reduce Alert Fatigue and Suggestions for Alert Fatigue Metrics.

    PubMed

    Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D

    2017-09-01

    To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.

  11. Health information technology to guide pediatric obesity management.

    PubMed

    McDonald, Julia; Goldman, Roberta E; O'Brien, Ashley; Ayash, Christine; Mitchell, Kathy; Marshall, Richard; Simon, Steven R; Taveras, Elsie M

    2011-06-01

    The purpose of this study was to examine pediatricians' familiarity with expert committee recommendations on the management of childhood obesity and their use of health information technology for obesity-related care. The authors interviewed 35 pediatricians from 17 primary care practices using an electronic health record; immersion crystallization facilitated analysis of the qualitative data. Nearly all pediatricians were unfamiliar with expert recommendations; however, all participants reported using growth charts and providing nutrition and physical activity counseling. Most participants wanted easy access to educational materials they could print for patients. The majority of participants were in favor of an electronic alert to identify obese patients, remind clinicians of current guidelines, and facilitate ordering, believing it would help standardize care. Concerns included "alert fatigue," distraction, and disruption of workflow. Suggestions for future electronic functions included tailored educational materials and physical activity resources customized by patient address.

  12. Unrestricted evening use of light-emitting tablet computers delays self-selected bedtime and disrupts circadian timing and alertness.

    PubMed

    Chinoy, Evan D; Duffy, Jeanne F; Czeisler, Charles A

    2018-05-01

    Consumer electronic devices play an important role in modern society. Technological advancements continually improve their utility and portability, making possible the near-constant use of electronic devices during waking hours. For most people, this includes the evening hours close to bedtime. Evening exposure to light-emitting (LE) devices can adversely affect circadian timing, sleep, and alertness, even when participants maintain a fixed 8-hour sleep episode in darkness and the duration of evening LE-device exposure is limited. Here, we tested the effects of evening LE-device use when participants were allowed to self-select their bedtimes, with wake times fixed as on work/school days. Nine healthy adults (3 women, 25.7 ± 3.0 years) participated in a randomized and counterbalanced study comparing five consecutive evenings of unrestricted LE-tablet computer use versus evenings reading from printed materials. On evenings when using LE-tablets, participants' self-selected bedtimes were on average half an hour later (22:03 ± 00:48 vs. 21:32 ± 00:27 h; P = 0.030), and they showed suppressed melatonin levels (54.17 ± 18.00 vs. 9.75 ± 22.75%; P < 0.001), delayed timing of melatonin secretion onset (20:23 ± 01:06 vs. 19:35 ± 00:59 h; P < 0.001), and later sleep onset (22:25 ± 00:54 vs. 21:54 ± 00:25 h; P = 0.041). When using LE-tablets, participants rated themselves as less sleepy in the evenings (P = 0.030) and less alert in the first hour after awakening on the following mornings (P < 0.001). These findings demonstrate that evening use of LE-tablets can induce delays in self-selected bedtimes, suppress melatonin secretion, and impair next-morning alertness, which may impact the health, performance, and safety of users. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  13. E-Learning. Trends and Issues Alert.

    ERIC Educational Resources Information Center

    Imel, Susan

    Electronic learning, also known as e-learning, is generally defined as instruction and learning experiences that are delivered via electronic technology such as the Internet, audiotape and videotape, satellite broadcast, interactive television, and CD-ROM. Web-based learning, computer-based learning, and virtual classrooms are some of the…

  14. Prescription order risk factors for pediatric dosing alerts.

    PubMed

    Stultz, J S; Porter, K; Nahata, M C

    2015-02-01

    To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.

    PubMed

    Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A

    2017-11-01

    Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.

  16. Evaluation of Nursing Documentation Completion of Stroke Patients in the Emergency Department: A Pre-Post Analysis Using Flowsheet Templates and Clinical Decision Support.

    PubMed

    Richardson, Karen J; Sengstack, Patricia; Doucette, Jeffrey N; Hammond, William E; Schertz, Matthew; Thompson, Julie; Johnson, Constance

    2016-02-01

    The primary aim of this performance improvement project was to determine whether the electronic health record implementation of stroke-specific nursing documentation flowsheet templates and clinical decision support alerts improved the nursing documentation of eligible stroke patients in seven stroke-certified emergency departments. Two system enhancements were introduced into the electronic record in an effort to improve nursing documentation: disease-specific documentation flowsheets and clinical decision support alerts. Using a pre-post design, project measures included six stroke management goals as defined by the National Institute of Neurological Disorders and Stroke and three clinical decision support measures based on entry of orders used to trigger documentation reminders for nursing: (1) the National Institutes of Health's Stroke Scale, (2) neurological checks, and (3) dysphagia screening. Data were reviewed 6 months prior (n = 2293) and 6 months following the intervention (n = 2588). Fisher exact test was used for statistical analysis. Statistical significance was found for documentation of five of the six stroke management goals, although effect sizes were small. Customizing flowsheets to meet the needs of nursing workflow showed improvement in the completion of documentation. The effects of the decision support alerts on the completeness of nursing documentation were not statistically significant (likely due to lack of order entry). For example, an order for the National Institutes of Health Stroke Scale was entered only 10.7% of the time, which meant no alert would fire for nursing in the postintervention group. Future work should focus on decision support alerts that trigger reminders for clinicians to place relevant orders for this population.

  17. Integration of physical abuse clinical decision support into the electronic health record at a Tertiary Care Children's Hospital.

    PubMed

    Suresh, Srinivasan; Saladino, Richard A; Fromkin, Janet; Heineman, Emily; McGinn, Tom; Richichi, Rudolph; Berger, Rachel P

    2018-04-12

    To evaluate the effect of a previously validated electronic health record-based child abuse trigger system on physician compliance with clinical guidelines for evaluation of physical abuse. A randomized controlled trial (RCT) with comparison to a preintervention group was performed. RCT-experimental subjects' providers received alerts with a direct link to a physical abuse-specific order set. RCT-control subjects' providers had no alerts, but could manually search for the order set. Preintervention subjects' providers had neither alerts nor access to the order set. Compliance with clinical guidelines was calculated. Ninety-nine preintervention subjects and 130 RCT subjects (73 RCT-experimental and 57 RCT-control) met criteria to undergo a physical abuse evaluation. Full compliance with clinical guidelines was 84% pre-intervention, 86% in RCT-control group, and 89% in RCT-experimental group. The physical abuse order set was used 43 times during the 7-month RCT. When the abuse order set was used, full compliance was 100%. The proportion of cases in which there was partial compliance decreased from 10% to 3% once the order set became available (P = .04). Male gender, having >10 years of experience and completion of a pediatric emergency medicine fellowship were associated with increased compliance. A child abuse clinical decision support system comprised of a trigger system, alerts and a physical abuse order set was quickly accepted into clinical practice. Use of the physical abuse order set always resulted in full compliance with clinical guidelines. Given the high baseline compliance at our site, evaluation of this alert system in hospitals with lower baseline compliance rates will be more valuable in assessing the efficacy in adherence to clinical guidelines for the evaluation of suspected child abuse.

  18. Using the Electronic Medical Record to Refer Women Taking Category D or X Medications for Teratogen and Contraceptive Counseling

    PubMed Central

    Mody, Sheila K.; Wu, Jennifer; Ornelas, Marla; Kernahan, Colleen; Salas, Elizabeth; Kao, Kelly; Felix, Robert; Chambers, Christina

    2015-01-01

    Background Women taking teratogens may not receive teratogen and contraceptive counseling. The objective of this study is to explore the feasibility of an electronic medical record (EMR) alert and referral system to improve teratogen and contraceptive counseling. Methods We conducted a descriptive study in an academic outpatient setting to evaluate the feasibility of an EMR alert and referral system. Reproductive age women taking category D or X medications seen in family medicine clinics were referred by means of an EMR alert for teratogen and contraceptive counseling. A subset of these women consented to follow-up surveys assessing contraceptive usage before counseling, intended contraceptive method after counseling and satisfaction with the counseling. Participants were contacted at 1 and 3 months to assess contraceptive usage. Results A total of 354 women were prescribed category D or X medications by clinicians who received the EMR alert, 170 women were referred, 59 women received counseling, and 33 participants enrolled in the study. One participant did not use any contraception. Among the 32 participants using contraception, 12 (37.5%) used oral contraceptives, 11 (34.4%) used condoms, 3 (9.4%) used withdrawal, 3 (9.4%) used intrauterine devices, 2 (6.3%) used contraceptive rings, and 1 (3.1%) used the diaphragm. After counseling, one-third of participants were considering more effective contraception. Almost all participants strongly agreed or agreed that the counseling was helpful. Conclusion Creating an EMR alert and referral system for women prescribed category X or D medications is feasible. Counseling on teratogen exposure and contraception may improve the acceptability of more effective contraception. PMID:26100297

  19. Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

    PubMed

    Nutman, A; Fisher Even-Tsur, S; Shapiro, G; Braun, T; Schwartz, D; Carmeli, Y

    2016-09-01

    Rapid identification of the causative pathogen in patients with bacteremia allows adjustment of antibiotic therapy and improves patient outcomes. We compared in vitro and real-life time to detection (TTD) of two blood culture media, BacT/Alert FA (FA) and BacT/Alert FA Plus (FA Plus), for the nine most common species of bacterial pathogens recovered from blood samples. Experimental data from simulated cultures was compared with microbiology records of TTD for both culture media with growth of the species of interest in clinical blood cultures. In the experimental conditions, median TTD was 3.8 hours (23.9 %) shorter using FA Plus media. The magnitude of reduction differed between species. Similarly, in real life data, FA Plus had shorter TTD than FA media; however, the difference between culture media was smaller, and median TTD was only 1 hour (8.5 %) less. We found shorter TTD with BacT/Alert FA Plus culture media, both experimentally and in real-life conditions and unrelated to antibiotic neutralization, highlighting the importance of appropriate blood culture media selection.

  20. The Low-Level Wind Shear Alert System (LLWSAS)

    DTIC Science & Technology

    1980-05-01

    ALERT SYSTEM (LLWSAS). (May R.. a.-ol - 8..’P" Imng Organization Report No, 9, Perfo~ring Or~ni-otlon Ro-r. -andAddress 10. Work Unit No. (TRAIS) Federal...rather than electronic approach. The 2-minute average adheres to recommended International Civil Aviation Organization (ICAO) standards (referernce 14...speed of 140 knots. **Cold front. 80 ’ # 90 0 STRONG CASES: COFF , 1975 80 9STRONG CASES: UNPU1BLISHED 70 60 A STRONG CASES: COFF , et al., 1978 50 \\ 50 -0

  1. Auditory decision aiding in supervisory control of multiple unmanned aerial vehicles.

    PubMed

    Donmez, Birsen; Cummings, M L; Graham, Hudson D

    2009-10-01

    This article is an investigation of the effectiveness of sonifications, which are continuous auditory alerts mapped to the state of a monitored task, in supporting unmanned aerial vehicle (UAV) supervisory control. UAV supervisory control requires monitoring a UAV across multiple tasks (e.g., course maintenance) via a predominantly visual display, which currently is supported with discrete auditory alerts. Sonification has been shown to enhance monitoring performance in domains such as anesthesiology by allowing an operator to immediately determine an entity's (e.g., patient) current and projected states, and is a promising alternative to discrete alerts in UAV control. However, minimal research compares sonification to discrete alerts, and no research assesses the effectiveness of sonification for monitoring multiple entities (e.g., multiple UAVs). The authors conducted an experiment with 39 military personnel, using a simulated setup. Participants controlled single and multiple UAVs and received sonifications or discrete alerts based on UAV course deviations and late target arrivals. Regardless of the number of UAVs supervised, the course deviation sonification resulted in reactions to course deviations that were 1.9 s faster, a 19% enhancement, compared with discrete alerts. However, course deviation sonifications interfered with the effectiveness of discrete late arrival alerts in general and with operator responses to late arrivals when supervising multiple vehicles. Sonifications can outperform discrete alerts when designed to aid operators to predict future states of monitored tasks. However, sonifications may mask other auditory alerts and interfere with other monitoring tasks that require divided attention. This research has implications for supervisory control display design.

  2. Targeting Alertness to Improve Cognition in Older Adults: A Preliminary Report of Benefits in Executive Function and Skill Acquisition

    PubMed Central

    Van Vleet, Thomas M.; DeGutis, Joseph M.; Merzenich, Michael M.; Simpson, Gregory V.; Zomet, Ativ; Dabit, Sawsan

    2016-01-01

    Efficient self-regulation of alertness declines with age exacerbating normal declines in performance across multiple cognitive domains, including learning and skill acquisition. Previous cognitive intervention studies have shown that it is possible to enhance alertness in patients with acquired brain injury and marked attention impairments, and that this benefit generalizes to improvements in more global cognitive functions. In the current preliminary studies, we sought to test whether this approach, that targets both tonic (over a period of minutes) and phasic (moment-to-moment) alertness, can improve key executive functioning declines in older adults, and enhance the rate of skill acquisition. The results of both experiments 1 and 2 demonstrate that, compared to active control training, alertness training significantly enhanced performance in several validated executive function measures. In experiment 2, alertness training significantly improved skill acquisition compared to active control training in a well-characterized speed of processing task, with the largest benefits shown in the most challenging speed of processing blocks. The results of the current study suggest that targeting intrinsic alertness in cognitive training provides a novel approach to improve executive functions in older adults and may be a useful adjunct treatment to enhance benefits gained in other clinically validated treatments. PMID:27372902

  3. A Retrospective Study on Patient Characteristics and Telehealth Alerts Indicative of Key Medical Events for Heart Failure Patients at a Home Health Agency

    PubMed Central

    Bowles, Kathryn; Hanlon, Alexandra; Topaz, Maxim; Chittams, Jesse

    2013-01-01

    Abstract Objective: To explore association of patient characteristics and telehealth alert data with all-cause key medical events (KMEs) of emergency department (ED) visits and hospitalizations as well as cardiac-related KMEs of ED visits, hospitalizations, and medication changes. Materials and Methods: A 6-month retrospective study was conducted of electronic patient records of heart failure (HF) patients using telehealth services at a Massachusetts home health agency. Data collected included patient demographic, psychosocial, disease severity factors and telehealth vital signs alerts. Association between patient characteristics and KMEs was analyzed by Generalized Estimating Equations. Results: The sample comprised 168 patients with a mean age of 83 years, 56% females, and 96% white. Ninety-nine cardiac-related KMEs and 87 all-cause KMEs were recorded for the subjects. Odds of a cardiac-related KME increased by 161% with the presence of valvular co-morbidity (p=0.001) and 106% with increased number of telehealth alerts (adjusted p<0.0001). Odds of an all-cause KME increased by 124% (p=0.02), 127% (p=0.01), and 70% (adjusted p<0.0001) with the presence of cancer co-morbidity, anxiety, and increased number of telehealth alerts, respectively. Overall, only 3% of all telehealth alerts were associated with KMEs. Conclusions: The very low proportion of telehealth vital sign alerts associated with KMEs indicates that telehealth alerts alone cannot inform the need for intervention within the larger context of HF care delivery in the homecare setting. Patient-relevant data such as psychosocial and symptom status, involvement with HF self-management, and presence of co-morbidities could further inform the need for interventions for HF patients in the homecare setting. PMID:23808888

  4. Implementation of a closed-loop reporting system for critical values and clinical communication in compliance with goals of the joint commission.

    PubMed

    Parl, Fritz F; O'Leary, Mandy F; Kaiser, Allen B; Paulett, John M; Statnikova, Kristina; Shultz, Edward K

    2010-03-01

    Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals. A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design. The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min. We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The Joint Commission's goals.

  5. Exploring the heavy air pollution in Beijing in the fourth quarter of 2015: assessment of environmental benefits for red alerts

    NASA Astrophysics Data System (ADS)

    Nie, Teng; Nie, Lei; Zhou, Zhen; Wang, Zhanshan; Xue, Yifeng; Gao, Jiajia; Wu, Xiaoqing; Fan, Shoubin; Cheng, Linglong

    2018-06-01

    In recent years, Beijing has experienced severe air pollution which has caused widespread public concern. Compared to the same period in 2014, the first three quarters of 2015 exhibited significantly improved air quality. However, the air quality sharply declined in the fourth quarter of 2015, especially in November and December. During that time, Beijing issued the first red alert for severe air pollution in history. In total, 2 red alerts, 3 orange alerts, 3 yellow alerts, and 3 blue alerts were issued based on the adoption of relatively temporary emergency control measures to mitigate air pollution. This study explored the reasons for these variations in air quality and assessed the effectiveness of emergency alerts in addressing severe air pollution. A synthetic analysis of emission variations and meteorological conditions was performed to better understand these extreme air pollution episodes in the fourth quarter of 2015. The results showed that compared to those in the same period in 2014, the daily average emissions of air pollutants decreased in the fourth quarter of 2015. However, the emission levels of primary pollutants were still relatively high, which was the main intrinsic cause of haze episodes, and unfavorable meteorological conditions represented important external factors. Emergency control measures for heavy air pollution were implemented during this red alert period, decreasing the emissions of primary air pollutants by approximately 36% and the PM2.5 concentration by 11%‒21%.

  6. 26 CFR 1.401(a)-21 - Rules relating to the use of an electronic medium to provide applicable notices and to make...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... electronic system must be designed to alert the recipient, at the time an applicable notice is provided, to... electronic delivery of an applicable notice on a prospective basis at any time and explains the procedures... recipient has the effective ability to access. (3) Free paper copy of applicable notice. At the time the...

  7. 26 CFR 1.401(a)-21 - Rules relating to the use of an electronic medium to provide applicable notices and to make...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... electronic system must be designed to alert the recipient, at the time an applicable notice is provided, to... electronic delivery of an applicable notice on a prospective basis at any time and explains the procedures... recipient has the effective ability to access. (3) Free paper copy of applicable notice. At the time the...

  8. 26 CFR 1.401(a)-21 - Rules relating to the use of an electronic medium to provide applicable notices and to make...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... electronic system must be designed to alert the recipient, at the time an applicable notice is provided, to... electronic delivery of an applicable notice on a prospective basis at any time and explains the procedures... recipient has the effective ability to access. (3) Free paper copy of applicable notice. At the time the...

  9. 26 CFR 1.401(a)-21 - Rules relating to the use of an electronic medium to provide applicable notices and to make...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... electronic system must be designed to alert the recipient, at the time an applicable notice is provided, to... electronic delivery of an applicable notice on a prospective basis at any time and explains the procedures... recipient has the effective ability to access. (3) Free paper copy of applicable notice. At the time the...

  10. Centile-based early warning scores derived from statistical distributions of vital signs.

    PubMed

    Tarassenko, Lionel; Clifton, David A; Pinsky, Michael R; Hravnak, Marilyn T; Woods, John R; Watkinson, Peter J

    2011-08-01

    To develop an early warning score (EWS) system based on the statistical properties of the vital signs in at-risk hospitalised patients. A large dataset comprising 64,622 h of vital-sign data, acquired from 863 acutely ill in-hospital patients using bedside monitors, was used to investigate the statistical properties of the four main vital signs. Normalised histograms and cumulative distribution functions were plotted for each of the four variables. A centile-based alerting system was modelled using the aggregated database. The means and standard deviations of our population's vital signs are very similar to those published in previous studies. When compared with EWS systems based on a future outcome, the cut-off values in our system are most different for respiratory rate and systolic blood pressure. With four-hourly observations in a 12-h shift, about 1 in 8 at-risk patients would trigger our alerting system during the shift. A centile-based EWS system will identify patients with abnormal vital signs regardless of their eventual outcome and might therefore be more likely to generate an alert when presented with patients with redeemable morbidity or avoidable mortality. We are about to start a stepped-wedge clinical trial gradually introducing an electronic version of our EWS system on the trauma wards in a teaching hospital. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients

    PubMed Central

    Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C

    2014-01-01

    Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386

  12. Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation

    NASA Technical Reports Server (NTRS)

    Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James

    2015-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.

  13. Implementation of a simple electronic transfusion alert system decreases inappropriate ordering of packed red blood cells and plasma in a multi-hospital health care system.

    PubMed

    Smith, Matthew; Triulzi, Darrell J; Yazer, Mark H; Rollins-Raval, Marian A; Waters, Jonathan H; Raval, Jay S

    2014-12-01

    Prescriber adherence to institutional blood component ordering guidelines can be low. The goal of this study was to decrease red blood cell (RBC) and plasma orders that did not meet institutional transfusion guidelines by using data within the laboratory information system to trigger alerts in the computerized order entry (CPOE) system at the time of order entry. At 10 hospitals within a regional health care system, discernment rules were created for RBC and plasma orders utilizing transfusion triggers of hemoglobin <8 gm/dl and INR >1.6, respectively, with subsequent alert generation that appears within the CPOE system when a prescriber attempts to order RBCs or plasma on a patient whose antecedent laboratory values do not suggest that a transfusion is indicated. Orders and subsequent alerts were tracked for RBCs and plasma over evaluation periods of 15 and 10 months, respectively, along with the hospital credentials of the ordering health care providers (physician or nurse). Alerts triggered which were heeded remained steady and averaged 11.3% for RBCs and 19.6% for plasma over the evaluation periods. Overall, nurses and physicians canceled statistically identical percentages of alerted RBC (10.9% vs. 11.5%; p = 0.78) and plasma (21.3% vs. 18.7%; p = 0.22) orders. Implementing a simple evidence-based transfusion alert system at the time of order entry decreased non-evidence based transfusion orders by both nurse and physician providers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Redesign of Library Workflows: Experimental Models for Electronic Resource Description.

    ERIC Educational Resources Information Center

    Calhoun, Karen

    This paper explores the potential for and progress of a gradual transition from a highly centralized model for cataloging to an iterative, collaborative, and broadly distributed model for electronic resource description. The purpose is to alert library managers to some experiments underway and to help them conceptualize new methods for defining,…

  15. A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.

    PubMed

    Page, N; Baysari, M T; Westbrook, J I

    2017-09-01

    To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Warning Alert HITL Experiment Results

    NASA Technical Reports Server (NTRS)

    Monk, Kevin J.; Ferm, Lisa; Roberts, Zach

    2018-01-01

    Minimum Operational Performance Standards (MOPS) are being developed to support the integration of Unmanned Aircraft Systems (UAS) in the National Airspace (NAS). Input from subject matter experts and multiple research studies have informed display requirements for Detect-and-Avoid (DAA) systems aimed at supporting timely and appropriate pilot responses to collision hazards. Phase 1 DAA MOPS alerting is designed to inform pilots if an avoidance maneuver is necessary; the two highest alert levels - caution and warning - indicate how soon pilot action is required and whether there is adequate time to coordinate with the air traffic controller (ATC). Additional empirical support is needed to clarify the extent to which warning-level alerting impacts DAA task performance. The present study explores the differential effects of the auditory and visual cues provided by the DAA Warning alert, and performance implications compared to caution-only alerting are discussed.

  17. The Impact of Alerting Designs on Air Traffic Controller's Eye Movement Patterns and Situation Awareness.

    PubMed

    Kearney, Peter; Li, Wen-Chin; Yu, Chung-San; Braithwaite, Graham

    2018-06-26

    This research investigated controller' situation awareness by comparing COOPANS's acoustic alerts with newly designed semantic alerts. The results demonstrate that ATCOs' visual scan patterns had significant differences between acoustic and semantic designs. ATCOs established different eye movement patterns on fixations number, fixation duration and saccade velocity. Effective decision support systems require human-centred design with effective stimuli to direct ATCO's attention to critical events. It is necessary to provide ATCOs with specific alerting information to reflect the nature of of the critical situation in order to minimize the side-effects of startle and inattentional deafness. Consequently, the design of a semantic alert can significantly reduce ATCOs' response time, therefore providing valuable extra time in a time-limited situation to formulate and execute resolution strategies in critical air safety events. The findings of this research indicate that the context-specified design of semantic alerts could improve ATCO's situational awareness and significantly reduce response time in the event of Short Term Conflict Alert activation which alerts to two aircraft having less than the required lateral or vertical separation.

  18. Decreased functional connectivity and structural deficit in alertness network with right-sided temporal lobe epilepsy.

    PubMed

    Gao, Yujun; Zheng, Jinou; Li, Yaping; Guo, Danni; Wang, Mingli; Cui, Xiangxiang; Ye, Wei

    2018-04-01

    Patients with temporal lobe epilepsy (TLE) often suffer from alertness alterations. However, specific regions connected with alertness remain controversial, and whether these regions have structural impairment is also elusive. This study aimed to investigate the characteristics and neural mechanisms underlying the functions and structures of alertness network in patients with right-sided temporal lobe epilepsy (rTLE) by performing the attentional network test (ANT), resting-state functional magnetic resonance imaging (R-SfMRI), and diffusion tensor imaging (DTI).A total of 47 patients with rTLE and 34 healthy controls underwent ANT, R-SfMRI, and DTI scan. The seed-based functional connectivity (FC) method and deterministic tractography were used to analyze the data.Patients with rTLE had longer reaction times in the no-cue and double-cue conditions. However, no differences were noted in the alertness effect between the 2 groups. The patient group had lower FC compared with the control group in the right inferior parietal lobe (IPL), amygdala, and insula. Structural deficits were found in the right parahippocampal gyrus, superior temporal pole, insula, and amygdala in the patient group compared with the control group. Also significantly negative correlations were observed between abnormal fractional anisotropy (between the right insula and the superior temporal pole) and illness duration in the patients with rTLE.The findings of this study suggested abnormal intrinsic and phasic alertness, decreased FC, and structural deficits within the alerting network in the rTLE. This study provided new insights into the mechanisms of alertness alterations in rTLE.

  19. Diurnal Spectral Sensitivity of the Acute Alerting Effects of Light

    PubMed Central

    Rahman, Shadab A.; Flynn-Evans, Erin E.; Aeschbach, Daniel; Brainard, George C.; Czeisler, Charles A.; Lockley, Steven W.

    2014-01-01

    Study Objectives: Previous studies have demonstrated short-wavelength sensitivity for the acute alerting response to nocturnal light exposure. We assessed daytime spectral sensitivity in alertness, performance, and waking electroencephalogram (EEG). Design: Between-subjects (n = 8 per group). Setting: Inpatient intensive physiologic monitoring unit. Participants: Sixteen healthy young adults (mean age ± standard deviation = 23.8 ± 2.7 y). Interventions: Equal photon density exposure (2.8 × 1013 photons/cm2/s) to monochromatic 460 nm (blue) or 555 nm (green) light for 6.5 h centered in the middle of the 16-h episode of wakefulness during the biological day. Results were compared retrospectively to 16 individuals who were administered the same light exposure during the night. Measurements and Results: Daytime and nighttime 460-nm light exposure significantly improved auditory reaction time (P < 0.01 and P < 0.05, respectively) and reduced attentional lapses (P < 0.05), and improved EEG correlates of alertness compared to 555-nm exposure. Whereas subjective sleepiness ratings did not differ between the two spectral conditions during the daytime (P > 0.05), 460-nm light exposure at night significantly reduced subjective sleepiness compared to 555-nm light exposure at night (P < 0.05). Moreover, nighttime 460-nm exposure improved alertness to near-daytime levels. Conclusions: The alerting effects of short-wavelength 460-nm light are mediated by counteracting both the circadian drive for sleepiness and homeostatic sleep pressure at night, but only via reducing the effects of homeostatic sleep pressure during the day. Citation: Rahman SA; Flynn-Evans EE; Aeschbach D; Brainard GC; Czeisler CA; Lockley SW. Diurnal spectral sensitivity of the acute alerting effects of light. SLEEP 2014;37(2):271-281. PMID:24501435

  20. Predicting Sepsis Risk Using the "Sniffer" Algorithm in the Electronic Medical Record.

    PubMed

    Olenick, Evelyn M; Zimbro, Kathie S; DʼLima, Gabrielle M; Ver Schneider, Patricia; Jones, Danielle

    The Sepsis "Sniffer" Algorithm (SSA) has merit as a digital sepsis alert but should be considered an adjunct to versus an alternative for the Nurse Screening Tool (NST), given lower specificity and positive predictive value. The SSA reduced the risk of incorrectly categorizing patients at low risk for sepsis, detected sepsis high risk in half the time, and reduced redundant NST screens by 70% and manual screening hours by 64% to 72%. Preserving nurse hours expended on manual sepsis alerts may translate into time directed toward other patient priorities.

  1. An Obstacle Alerting System for Agricultural Application

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe

    2003-01-01

    Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.

  2. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes

    PubMed Central

    Los, Evan A.; Ramsey, Katrina L.; Guttmann-Bauman, Ines; Ahmann, Andrew J.

    2016-01-01

    Background: We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Methods: Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Results: Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog’s ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). Conclusions: This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin. PMID:27573791

  3. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes.

    PubMed

    Los, Evan A; Ramsey, Katrina L; Guttmann-Bauman, Ines; Ahmann, Andrew J

    2017-05-01

    We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog's ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin.

  4. Insider Alert 1.0 Beta Version

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, Robert

    2004-02-01

    Insider Alert 1.0 Beta Version supports interactive selection and graphical display of data generated by the Sandia Cognitive Framework, which simulates the examination of security data by experts of various specialties. Insider Alert also encompasses the configuration and data files input to the Cognitive Framework for this application. Insider Alert 1.0 Beta Version is a computer program for analyzing data indicative of possible espionage or improper handling of data by employees at Sandia National Laboratories (or other facilities with comparable policies and procedures for managing sensitive information) It prioritizes and displays information for review by security analysts.

  5. Electronic alerts and clinician turnover: the influence of user acceptance.

    PubMed

    Hysong, Sylvia J; Spitzmuller, Christiane; Espadas, Donna; Sittig, Dean F; Singh, Hardeep

    2014-11-01

    Use of certain components of electronic health records (EHRs), such as EHR-based alerting systems (EASs), might reduce provider satisfaction, a strong precursor to turnover. We examined the impact of factors likely to influence providers' acceptance of an alerting system, designed to facilitate electronic communication in outpatient settings, on provider satisfaction, intentions to quit, and turnover. We conducted a cross-sectional Web-based survey of EAS-related practices from a nationwide sample of primary care providers (PCPs) practicing at Department of Veterans Affairs (VA) medical facilities. Of 5001 invited VA PCPs, 2590 completed the survey. We relied on Venkatesh's Unified Theory of Acceptance and Use of Technology to create survey measures of 4 factors likely to impact user acceptance of EAS: supportive norms, monitoring/ feedback, training, and providers' perceptions of the value (PPOV) of EASs to provider effectiveness. Facility-level PCP turnover was measured via the VA's Service Support Center Human Resources Cube. Hypotheses were tested using structural equation modeling. After accounting for intercorrelations among predictors, monitoring/feedback regarding EASs significantly predicted intention to quit (b = 0.30, P < .01), and PPOV of EASs predicted both overall provider satisfaction (b = 0.58, P < .01) and facility-level provider turnover levels (b = -0.19, P < .05), all without relying on any intervening mechanisms. Design, implementation, and use of EASs might impact provider satisfaction and retention. Institutions should consider strategies to help providers perceive greater value in these clinical tools.

  6. Pilot evaluation of a method to assess prescribers' information processing of medication alerts.

    PubMed

    Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J

    2017-02-01

    Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the revised versus original alert display (p=0.006). With the revised display, more prescribers accurately reported that three warnings were shown (p=0.002). The methodological protocol was feasible for evaluating the alert display and yielded important findings on prescribers' information processing. Study methods supplement traditional usability evaluation methods and may be useful for evaluating information processing of other healthcare technologies. Published by Elsevier Inc.

  7. Optimizing the response to surveillance alerts in automated surveillance systems.

    PubMed

    Izadi, Masoumeh; Buckeridge, David L

    2011-02-28

    Although much research effort has been directed toward refining algorithms for disease outbreak alerting, considerably less attention has been given to the response to alerts generated from statistical detection algorithms. Given the inherent inaccuracy in alerting, it is imperative to develop methods that help public health personnel identify optimal policies in response to alerts. This study evaluates the application of dynamic decision making models to the problem of responding to outbreak detection methods, using anthrax surveillance as an example. Adaptive optimization through approximate dynamic programming is used to generate a policy for decision making following outbreak detection. We investigate the degree to which the model can tolerate noise theoretically, in order to keep near optimal behavior. We also evaluate the policy from our model empirically and compare it with current approaches in routine public health practice for investigating alerts. Timeliness of outbreak confirmation and total costs associated with the decisions made are used as performance measures. Using our approach, on average, 80 per cent of outbreaks were confirmed prior to the fifth day of post-attack with considerably less cost compared to response strategies currently in use. Experimental results are also provided to illustrate the robustness of the adaptive optimization approach and to show the realization of the derived error bounds in practice. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Real-Time Mapping alert system; user's manual

    USGS Publications Warehouse

    Torres, L.A.

    1996-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water- related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field monitoring sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. These alert values can help keep water- resource specialists informed of current hydrologic conditions. The current alert status at monitoring sites is of critical importance during floods, hurricanes, and other extreme hydrologic events where quick analysis of the situation is needed. This manual provides instructions for using the Real-Time Mapping software, a series of computer programs developed by the U.S. Geological Survey for quick analysis of hydrologic conditions, and guides users through a basic interactive session. The software provides interactive graphics display and query of real-time information in a map-based, menu-driven environment.

  9. Improved management of acute kidney injury in primary care using e-alerts and an educational outreach programme.

    PubMed

    Tollitt, James; Flanagan, Emma; McCorkindale, Sheila; Glynn-Atkins, Sam; Emmett, Lauren; Darby, Denise; Ritchie, James; Bennett, Brandon; Sinha, Smeeta; Poulikakos, Dimitrios

    2018-04-28

    Acute kidney injury (AKI) detected in primary care is associated with increased morbidity and mortality. AKI electronic alerts (e-alerts) and educational programmes have recently been implemented but their contribution to improve AKI care is unknown. This project aimed to improve response to AKI detected in primary care and used a factorial design to evaluate the impact of the UK National Health Service (NHS) AKI e-alert and AKI educational outreach sessions on time to response to primary care AKI stages 2 and 3 between April and August 2016. A total of 46 primary care practices were randomized into four groups. A 2 × 2 factorial design exposed each group to different combinations of two interventions. The primary outcome was 'time to repeat test' or hospitalization following AKI e-alert for stages 2 and 3. Yates algorithm was used to evaluate the impact of each intervention. Time to response and mortality pre- and post-intervention were analysed using Mann-Whitney U test and chi-square test respectively. The factorial design included two interventions: an AKI educational outreach programme and the NHS AKI e-alerts. 1807 (0.8%) primary care blood tests demonstrated AKI 1-3 (78.3% stage 1, 14.8% stage 2, 6.9% stage 3). There were 391 stage 2 and 3 events from 251 patients. E-alerts demonstrated a reduction in mean response time (-29 hours). Educational outreach had a smaller effect (-3 hours). Median response time to AKI 2 and 3 pre- and post-interventions was 27 hours versus 16 hours respectively (P = 0.037). Stage 2 and 3 event-related 30-day all-cause mortality decreased following the interventions (15.6% versus 3.9% P = 0.036). AKI e-alerts in primary care hasten response to AKI 2 and 3 and reduce all-cause mortality. Educational outreach sessions further improve response time.

  10. Stimulated reporting: the impact of US food and drug administration-issued alerts on the adverse event reporting system (FAERS).

    PubMed

    Hoffman, Keith B; Demakas, Andrea R; Dimbil, Mo; Tatonetti, Nicholas P; Erdman, Colin B

    2014-11-01

    The US Food and Drug Administration (FDA) uses the Adverse Event Reporting System (FAERS) to support post-marketing safety surveillance programs. Currently, almost one million case reports are submitted to FAERS each year, making it a vast repository of drug safety information. Sometimes cited as a limitation of FAERS, however, is the assumption that "stimulated reporting" of adverse events (AEs) occurs in response to warnings, alerts, and label changes that are issued by the FDA. To determine the extent of "stimulated reporting" in the modern-day FAERS database. One hundred drugs approved by the FDA between 2001 and 2010 were included in this analysis. FDA alerts were obtained by a comprehensive search of the FDA's MedWatch and main websites. Publicly available FAERS data were used to assess the "primary suspect" AE reporting pattern for up to four quarters before, and after, the issuance of an FDA alert. A few drugs did demonstrate "stimulated reporting" trends. A majority of the drugs, however, showed little evidence for significant reporting changes associated with the issuance of alerts. When we compared the percentage changes in reporting after an FDA alert with those after a sham "control alert", the overall reporting trends appeared to be quite similar. Of 100 drugs analyzed for short-term reporting trends, 21 real alerts and 25 sham alerts demonstrated an increase (greater than or equal to 1 %) in reporting. The long-term analysis of 91 drugs showed that 24 real alerts and 28 sham alerts demonstrated a greater than or equal to 1 % increase. Our results suggest that most of modern day FAERS reporting is not significantly affected by the issuance of FDA alerts.

  11. Influencing Anesthesia Provider Behavior Using Anesthesia Information Management System Data for Near Real-Time Alerts and Post Hoc Reports.

    PubMed

    Epstein, Richard H; Dexter, Franklin; Patel, Neil

    2015-09-01

    In this review article, we address issues related to using data from anesthesia information management systems (AIMS) to deliver near real-time alerts via AIMS workstation popups and/or alphanumeric pagers and post hoc reports via e-mail. We focus on reports and alerts for influencing the behavior of anesthesia providers (i.e., anesthesiologists, anesthesia residents, and nurse anesthetists). Multiple studies have shown that anesthesia clinical decision support (CDS) improves adherence to protocols and increases financial performance through facilitation of billing, regulatory, and compliance documentation; however, improved clinical outcomes have not been demonstrated. We inform developers and users of feedback systems about the multitude of concerns to consider during development and implementation of CDS to increase its effectiveness and to mitigate its potentially disruptive aspects. We discuss the timing and modalities used to deliver messages, implications of outlier-only versus individualized feedback, the need to consider possible unintended consequences of such feedback, regulations, sustainability, and portability among systems. We discuss statistical issues related to the appropriate evaluation of CDS efficacy. We provide a systematic review of the published literature (indexed in PubMed) of anesthesia CDS and offer 2 case studies of CDS interventions using AIMS data from our own institution illustrating the salient points. Because of the considerable expense and complexity of maintaining near real-time CDS systems, as compared with providing individual reports via e-mail after the fact, we suggest that if the same goal can be accomplished via delayed reporting versus immediate feedback, the former approach is preferable. Nevertheless, some processes require near real-time alerts to produce the desired improvement. Post hoc e-mail reporting from enterprise-wide electronic health record systems is straightforward and can be accomplished using system-independent pathways (e.g., via built-in e-mail support provided by the relational database management system). However, for some of these enterprise-wide systems, near real-time data access, necessary for CDS that generates concurrent alerts, has been challenging to implement.

  12. Semiautomated System for Nonurgent, Clinically Significant Pathology Results.

    PubMed

    O'Connor, Stacy D; Khorasani, Ramin; Pochebit, Stephen M; Lacson, Ronilda; Andriole, Katherine P; Dalal, Anuj K

    2018-04-01

     Failure of timely test result follow-up has consequences including delayed diagnosis and treatment, added costs, and potential patient harm. Closed-loop communication is key to ensure clinically significant test results (CSTRs) are acknowledged and acted upon appropriately. A previous implementation of the Alert Notification of Critical Results (ANCR) system to facilitate closed-loop communication of imaging CSTRs yielded improved communication of critical radiology results and enhanced adherence to institutional CSTR policies.  This article extends the ANCR application to pathology and evaluates its impact on closed-loop communication of new malignancies, a common and important type of pathology CSTR.  This Institutional Review Board-approved study was performed at a 150-bed community, academically affiliated hospital. ANCR was adapted for pathology CSTRs. Natural language processing was used on 30,774 pathology reports 13 months pre- and 13 months postintervention, identifying 5,595 reports with malignancies. Electronic health records were reviewed for documented acknowledgment for a random sample of reports. Percent of reports with documented acknowledgment within 15 days assessed institutional policy adherence. Time to acknowledgment was compared pre- versus postintervention and postintervention with and without ANCR alerts. Pathologists were surveyed regarding ANCR use and satisfaction.  Acknowledgment within 15 days was documented for 98 of 107 (91.6%) pre- and 89 of 103 (86.4%) postintervention reports ( p  = 0.2294). Median time to acknowledgment was 7 days (interquartile range [IQR], 3, 11) preintervention and 6 days (IQR, 2, 10) postintervention ( p  = 0.5083). Postintervention, median time to acknowledgment was 2 days (IQR, 1, 6) for reports with ANCR alerts versus 6 days (IQR, 2.75, 9) for reports without alerts ( p  = 0.0351). ANCR alerts were sent on 15 of 103 (15%) postintervention reports. All pathologists reported that the ANCR system positively impacted their workflow; 75% (three-fourths) felt that the ANCR system improved efficiency of communicating CSTRs.  ANCR expansion to facilitate closed-loop communication of pathology CSTRs was favorably perceived and associated with significant improved time to documented acknowledgment for new malignancies. The rate of adherence to institutional policy did not improve. Schattauer.

  13. Implementing an overdose education and naloxone distribution program in a health system.

    PubMed

    Devries, Jennifer; Rafie, Sally; Polston, Gregory

    To design and implement a health system-wide program increasing provision of take-home naloxone in patients at risk for opioid overdose, with the downstream aim of reducing fatalities. The program includes health care professional education and guidelines, development, and dissemination of patient education materials, electronic health record changes to promote naloxone prescriptions, and availability of naloxone in pharmacies. Academic health system, San Diego, California. University of California, San Diego Health (UCSDH), offers both inpatient and outpatient primary care and specialty services with 563 beds spanning 2 hospitals and 6 pharmacies. UCSDH is part of the University of California health system, and it serves as the county's safety net hospital. In January 2016, a multisite academic health system initiated a system-wide overdose education and naloxone distribution program to prevent opioid overdose and opioid overdose-related deaths. An interdisciplinary, interdepartmental team came together to develop and implement the program. To strengthen institutional support, naloxone prescribing guidelines were developed and approved for the health system. Education on naloxone for physicians, pharmacists, and nurses was provided through departmental trainings, bulletins, and e-mail notifications. Alerts in the electronic health record and preset naloxone orders facilitated co-prescribing of naloxone with opioid prescriptions. Electronic health record reports captured naloxone prescriptions ordered. Summary reports on the electronic health record measured naloxone reminder alerts and response rates. Since the start of the program, the health system has trained 252 physicians, pharmacists, and nurses in overdose education and take-home naloxone. There has been an increase in the number of prescriptions for naloxone from a baseline of 4.5 per month to an average of 46 per month during the 3 months following full implementation of the program including implementation of electronic health record alerts. Initiating and implementing an overdose education and naloxone distribution program is feasible in an academic health system. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Alert Workplace From Healthcare Workers' Perspective: Behavioral and Environmental Strategies to Improve Vigilance and Alertness in Healthcare Settings.

    PubMed

    Sagah Zadeh, Rana; Shepley, Mardelle; Sadatsafavi, Hessam; Owora, Arthur Hamie; Krieger, Ana C

    2018-04-01

    This study aims to identify the behavioral and environmental strategies that healthcare workers view as helpful for managing sleepiness, improving alertness, and therefore optimizing workplace safety. Reduced alertness is a common issue in healthcare work environments and is associated with impaired cognitive performance and decision-making ability as well as increased errors and injuries. We surveyed 136 healthcare professionals at a primary care clinic, an acute care hospital, and a mental health clinic. Nonstructured, semistructured, and structured questionnaires were used to elicit relevant information which was analyzed using qualitative content analysis and logistic regression models, respectively. In order by frequency of endorsement: dietary intervention; physical mobility; cognitive, sensory, or social stimulation; personal lifestyle strategies; and rest/nap opportunities were reported as behavioral strategies used to address workplace alertness. Compared to other environmental features, daylight and thermal comfort were perceived to be more important to addressing workplace alertness ( p < .05). By optimizing the physical environment and organizational policies and providing education programs, we have an opportunity to support healthcare professionals in managing sleepiness and maintaining alertness at work. In addition, such system level interventions may reduce unhealthy choices such as frequent caffeine intake to keep alert. The development of multidisciplinary evidence-based guidelines is needed to address sleepiness and alertness to improve workplace safety in healthcare facilities.

  15. Human Factors Evaluation of Conflict Detection Tool for Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.

    2013-01-01

    A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.

  16. A graphical workstation based part-task flight simulator for preliminary rapid evaluation of advanced displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Kuchar, James; Hahn, Edward; Pritchett, A.; Hansman, R. John

    1994-01-01

    Advances in avionics and display technology are significantly changing the cockpit environment in current transport aircraft. The MIT Aeronautical Systems Lab (ASL) developed a part-task flight simulator specifically to study the effects of these new technologies on flight crew situational awareness and performance. The simulator is based on a commercially-available graphics workstation, and can be rapidly reconfigured to meet the varying demands of experimental studies. The simulator was successfully used to evaluate graphical microbursts alerting displays, electronic instrument approach plates, terrain awareness and alerting displays, and ATC routing amendment delivery through digital datalinks.

  17. Real-Time Mapping alert system; characteristics and capabilities

    USGS Publications Warehouse

    Torres, L.A.; Lambert, S.C.; Liebermann, T.D.

    1995-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water-related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field sampling sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. The current alert status at monitoring sites within a state or region is of critical importance during floods, hurricanes, and other extreme hydrologic events. This report describes the characteristics and capabilities of a series of computer programs for real-time mapping of hydrologic data. The software provides interactive graphics display and query of hydrologic information from the network in a real-time, map-based, menu-driven environment.

  18. Employing clinical decision support to attain our strategic goal: the safe care of the surgical patient.

    PubMed

    Magid, Steven K; Pancoast, Paul E; Fields, Theodore; Bradley, Diane G; Williams, Robert B

    2007-01-01

    Clinical decision support can be employed to increase patient safety and improve workflow efficiencies for physicians and other healthcare providers. Physician input into the design and deployment of clinical decision support systems can increase the utility of the alerts and reduce the likelihood of "alert fatigue." The Hospital for Special Surgery is a 146-bed orthopedic facility that performs approximately 18,000 surgeries a year Efficient work processes are a necessity. The facility began implementing a new electronic health record system in June 2005 and plan to go live in summer 2007. This article reports on some of the clinical decision support rules and alerts being incorporated into the facility's system in the following categories--high-risk, high-frequency scenarios, rules that provide efficiencies and value from the presciber perspective, and rules that relate to patient safety.

  19. The Hub Population Health System: distributed ad hoc queries and alerts

    PubMed Central

    Anane, Sheila; Taverna, John; Amirfar, Sam; Stubbs-Dame, Remle; Singer, Jesse

    2011-01-01

    The Hub Population Health System enables the creation and distribution of queries for aggregate count information, clinical decision support alerts at the point-of-care for patients who meet specified conditions, and secure messages sent directly to provider electronic health record (EHR) inboxes. Using a metronidazole medication recall, the New York City Department of Health was able to determine the number of affected patients and message providers, and distribute an alert to participating practices. As of September 2011, the system is live in 400 practices and within a year will have over 532 practices with 2500 providers, representing over 2.5 million New Yorkers. The Hub can help public health experts to evaluate population health and quality improvement activities throughout the ambulatory care network. Multiple EHR vendors are building these features in partnership with the department's regional extension center in anticipation of new meaningful use requirements. PMID:22071531

  20. Electronic prescribing system design priorities for antimicrobial stewardship: a cross-sectional survey of 142 UK infection specialists.

    PubMed

    Hand, Kieran S; Cumming, Debbie; Hopkins, Susan; Ewings, Sean; Fox, Andy; Theminimulle, Sandya; Porter, Robert J; Parker, Natalie; Munns, Joanne; Sheikh, Adel; Keyser, Taryn; Puleston, Richard

    2017-04-01

    The implementation of electronic prescribing and medication administration (EPMA) systems is a priority for hospitals and a potential component of antimicrobial stewardship (AMS). To identify software features within EPMA systems that could potentially facilitate AMS and to survey practising UK infection specialist healthcare professionals in order to assign priority to these software features. A questionnaire was developed using nominal group technique and transmitted via email links through professional networks. The questionnaire collected demographic data, information on priority areas and anticipated impact of EPMA. Responses from different respondent groups were compared using the Mann-Whitney U -test. Responses were received from 164 individuals (142 analysable). Respondents were predominantly specialist infection pharmacists (48%) or medical microbiologists (37%). Of the pharmacists, 59% had experience of EPMA in their hospitals compared with 35% of microbiologists. Pharmacists assigned higher priority to indication prompt ( P  <   0.001), allergy checker ( P  =   0.003), treatment protocols ( P  =   0.003), drug-indication mismatch alerts ( P  =   0.031) and prolonged course alerts ( P  =   0.041) and lower priority to a dose checker for adults ( P  =   0.02) and an interaction checker ( P  <   0.05) than microbiologists. A 'soft stop' functionality was rated essential or high priority by 89% of respondents. Potential EPMA software features were expected to have the greatest impact on stewardship, treatment efficacy and patient safety outcomes with lowest impact on Clostridium difficile infection, antimicrobial resistance and drug expenditure. The survey demonstrates key differences in health professionals' opinions of potential healthcare benefits of EPMA, but a consensus of anticipated positive impact on patient safety and AMS. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Performance of Two Resin-Containing Blood Culture Media in Detection of Bloodstream Infections and in Direct Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS) Broth Assays for Isolate Identification: Clinical Comparison of the BacT/Alert Plus and Bactec Plus Systems

    PubMed Central

    Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Spanu, Teresa

    2014-01-01

    We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization–time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. PMID:25031441

  2. The Acute Effects of Intermittent Light Exposure in the Evening on Alertness and Subsequent Sleep Architecture.

    PubMed

    Yang, Minqi; Ma, Ning; Zhu, Yingying; Su, Ying-Chu; Chen, Qingwei; Hsiao, Fan-Chi; Ji, Yanran; Yang, Chien-Ming; Zhou, Guofu

    2018-03-15

    Exposure to bright light is typically intermittent in our daily life. However, the acute effects of intermittent light on alertness and sleep have seldom been explored. To investigate this issue, we employed within-subject design and compared the effects of three light conditions: intermittent bright light (30-min pulse of blue-enriched bright light (~1000 lux, ~6000 K) alternating with 30-min dim normal light (~5 lux, ~3600 K) three times); continuous bright light; and continuous dim light on subjective and objective alertness and subsequent sleep structure. Each light exposure was conducted during the three hours before bedtime. Fifteen healthy volunteers (20 ± 3.4 years; seven males) were scheduled to stay in the sleep laboratory for four separated nights (one for adaptation and the others for the light exposures) with a period of at least one week between nights. The results showed that when compared with dim light, both intermittent light and continuous bright light significantly increased subjective alertness and decreased sleep efficiency (SE) and total sleep time (TST). Intermittent light significantly increased objective alertness than dim light did during the second half of the light-exposure period. Our results suggested that intermittent light was as effective as continuous bright light in their acute effects in enhancing subjective and objective alertness and in negatively impacting subsequent sleep.

  3. A randomised, clinical trial comparing the effectiveness of hospital and community-based reminder systems for increasing uptake of influenza and pneumococcal vaccine in hospitalised patients aged 65 years and over.

    PubMed

    MacIntyre, C R; Kainer, M A; Brown, G V

    2003-01-01

    Hospitalisation represents an opportunity to identify unimmunised people at risk for the complications of influenza and pneumococcal disease. We conducted a randomised controlled trial of two strategies to increase uptake of influenza and pneumococcal vaccines in eligible, hospitalised subjects aged 65 years or more, admitted between May and September 1998 to a Melbourne hospital. Unvaccinated participants were allocated randomly to alert systems for hospital staff or community general practitioners (GPs). Follow-up occurred at 1 and 3 months. The baseline vaccination rates were 70% for influenza (426/606) and 41% (248/606) for pneumococcal disease. For unvaccinated subjects, the hospital alert resulted in 67% uptake compared to 55% following a GP alert for pneumococcal vaccine; and 63% in hospital compared to 53% following a GP alert for influenza vaccine. Although there was a trend toward a higher uptake in hospital, neither of these differences was statistically significant. The majority (75%) of vaccinations following a GP alert occurred within 1 month of discharge. Despite hospital and community-based reminder systems, there are still significant missed opportunities for vaccination. We did not demonstrate significant differences between hospital and GP reminder systems, but there was a trend towards higher uptake with opportunistic vaccination in hospital. Copyright 2003 S. Karger AG, Basel

  4. A novel active heads-up display for driver assistance.

    PubMed

    Doshi, Anup; Cheng, Shinko Yuanhsien; Trivedi, Mohan Manubhai

    2009-02-01

    In this paper, we introduce a novel laser-based wide-area heads-up windshield display which is capable of actively interfacing with a human as part of a driver assistance system. The dynamic active display (DAD) is a unique prototype interface that presents safety-critical visual icons to the driver in a manner that minimizes the deviation of his or her gaze direction without adding to unnecessary visual clutter. As part of an automotive safety system, the DAD presents alerts in the field of view of the driver only if necessary, which is based upon the state and pose of the driver, vehicle, and environment. This paper examines the effectiveness of DAD through a comprehensive comparative experimental evaluation of a speed compliance driver assistance system, which is implemented on a vehicular test bed. Three different types of display protocols for assisting a driver to comply with speed limits are tested on actual roadways, and these are compared with a conventional dashboard display. Given the inclination, drivers who are given an overspeed warning alert reduced the time required to slow down to the speed limit by 38% (p < 0.01) as compared with the drivers not given the alert. Additionally, certain alerts decreased distraction levels by reducing the time spent looking away from the road by 63% (p < 0.01). Ultimately, these alerts demonstrate the utility and promise of the DAD system.

  5. Comparative analytics of infusion pump data across multiple hospital systems.

    PubMed

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  6. Interventions for implementation of thromboprophylaxis in hospitalized patients at risk for venous thromboembolism.

    PubMed

    Kahn, Susan R; Morrison, David R; Diendéré, Gisèle; Piché, Alexandre; Filion, Kristian B; Klil-Drori, Adi J; Douketis, James D; Emed, Jessica; Roussin, André; Tagalakis, Vicky; Morris, Martin; Geerts, William

    2018-04-24

    Venous thromboembolism (VTE) is a leading cause of morbidity and mortality in hospitalized patients. While numerous randomized controlled trials (RCTs) have shown that the appropriate use of thromboprophylaxis in hospitalized patients at risk for VTE is safe, effective, and cost-effective, thromboprophylaxis remains underused or inappropriately used. Our previous review suggested that system-wide interventions, such as education, alerts, and multifaceted interventions were more effective at improving the prescribing of thromboprophylaxis than relying on individual providers' behaviors. However, 47 of the 55 included studies in our previous review were observational in design. Thus, an update to our systematic review, focused on the higher level of evidence of RCTs only, was warranted. To assess the effects of system-wide interventions designed to increase the implementation of thromboprophylaxis and decrease the incidence of VTE in hospitalized adult medical and surgical patients at risk for VTE, focusing on RCTs only. Our research librarian conducted a systematic literature search of MEDLINE Ovid, and subsequently translated it to CENTRAL, PubMed, Embase Ovid, BIOSIS Previews Ovid, CINAHL, Web of Science, the Database of Abstracts of Reviews of Effects (DARE; in the Cochrane Library), NHS Economic Evaluation Database (EED; in the Cochrane Library), LILACS, and clinicaltrials.gov from inception to 7 January 2017. We also screened reference lists of relevant review articles. We identified 12,920 potentially relevant records. We included all types of RCTs, with random or quasi-random methods of allocation of interventions, which either randomized individuals (e.g. parallel group, cross-over, or factorial design RCTs), or groups of individuals (cluster RCTs (CRTs)), which aimed to increase the use of prophylaxis or appropriate prophylaxis, or decrease the occurrence of VTE in hospitalized adult patients. We excluded observational studies, studies in which the intervention was simply distribution of published guidelines, and studies whose interventions were not clearly described. Studies could be in any language. We collected data on the following outcomes: the number of participants who received prophylaxis or appropriate prophylaxis (as defined by study authors), the occurrence of any VTE (symptomatic or asymptomatic), mortality, and safety outcomes, such as bleeding. We categorized the interventions into alerts (computer or human alerts), multifaceted interventions (combination of interventions that could include an alert component), educational interventions (e.g. grand rounds, courses), and preprinted orders (written predefined orders completed by the physician on paper or electronically). We meta-analyzed data across RCTs using a random-effects model. For CRTs, we pooled effect estimates (risk difference (RD) and risk ratio (RR), with 95% confidence interval (CI), adjusted for clustering, when possible. We pooled results if three or more trials were available for a particular intervention. We assessed the certainty of the evidence according to the GRADE approach. From the 12,920 records identified by our search, we included 13 RCTs (N = 35,997 participants) in our qualitative analysis and 11 RCTs (N = 33,207 participants) in our meta-analyses. Alerts were associated with an increase in the proportion of participants who received prophylaxis (RD 21%, 95% CI 15% to 27%; three studies; 5057 participants; I² = 75%; low-certainty evidence). The substantial statistical heterogeneity may be in part explained by patient types, type of hospital, and type of alert. Subgroup analyses were not feasible due to the small number of studies included in the meta-analysis.Multifaceted interventions were associated with a small increase in the proportion of participants who received prophylaxis (cluster-adjusted RD 4%, 95% CI 2% to 6%; five studies; 9198 participants; I² = 0%; moderate-certainty evidence). Multifaceted interventions with an alert component were found to be more effective than multifaceted interventions that did not include an alert, although there were not enough studies to conduct a pooled analysis. Alerts were associated with an increase in the proportion of participants who received appropriate prophylaxis (RD 16%, 95% CI 12% to 20%; three studies; 1820 participants; I² = 0; moderate-certainty evidence). Alerts were also associated with a reduction in the rate of symptomatic VTE at three months (RR 64%, 95% CI 47% to 86%; three studies; 5353 participants; I² = 15%; low-certainty evidence). Computer alerts were associated with a reduction in the rate of symptomatic VTE, although there were not enough studies to pool computer alerts and human alerts results separately. We reviewed RCTs that implemented a variety of system-wide strategies aimed at improving thromboprophylaxis in hospitalized patients. We found increased prescription of prophylaxis associated with alerts and multifaceted interventions, and increased prescription of appropriate prophylaxis associated with alerts. While multifaceted interventions were found to be less effective than alerts, a multifaceted intervention with an alert was more effective than one without an alert. Alerts, particularly computer alerts, were associated with a reduction in symptomatic VTE at three months, although there were not enough studies to pool computer alerts and human alerts results separately.Our analysis was underpowered to assess the effect on mortality and safety outcomes, such as bleeding.The incomplete reporting of relevant study design features did not allow complete assessment of the certainty of the evidence. However, the certainty of the evidence for improvement in outcomes was judged to be better than for our previous review (low- to moderate-certainty evidence, compared to very low-certainty evidence for most outcomes). The results of our updated review will help physicians, hospital administrators, and policy makers make practical decisions about adopting specific system-wide measures to improve prescription of thromboprophylaxis, and ultimately prevent VTE in hospitalized patients.

  7. Development, implementation and outcome analysis of semi-automated alerts for metformin dose adjustment in hospitalized patients with renal impairment.

    PubMed

    Niedrig, David; Krattinger, Regina; Jödicke, Annika; Gött, Carmen; Bucklar, Guido; Russmann, Stefan

    2016-10-01

    Overdosing of the oral antidiabetic metformin in impaired renal function is an important contributory cause to life-threatening lactic acidosis. The presented project aimed to quantify and prevent this avoidable medication error in clinical practice. We developed and implemented an algorithm into a hospital's clinical information system that prospectively identifies metformin prescriptions if the estimated glomerular filtration rate is below 60 mL/min. Resulting real-time electronic alerts are sent to clinical pharmacologists and pharmacists, who validate cases in electronic medical records and contact prescribing physicians with recommendations if necessary. The screening algorithm has been used in routine clinical practice for 3 years and generated 2145 automated alerts (about 2 per day). Validated expert recommendations regarding metformin therapy, i.e., dose reduction or stop, were issued for 381 patients (about 3 per week). Follow-up was available for 257 cases, and prescribers' compliance with recommendations was 79%. Furthermore, during 3 years, we identified eight local cases of lactic acidosis associated with metformin therapy in renal impairment that could not be prevented, e.g., because metformin overdosing had occurred before hospitalization. Automated sensitive screening followed by specific expert evaluation and personal recommendations can prevent metformin overdosing in renal impairment with high efficiency and efficacy. Repeated cases of metformin-associated lactic acidosis in renal impairment underline the clinical relevance of this medication error. Our locally developed and customized alert system is a successful proof of concept for a proactive clinical drug safety program that is now expanded to other clinically and economically relevant medication errors. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Terrain Display Alternatives Assessment of Information Density and Alerting Strategies

    DOT National Transportation Integrated Search

    1998-04-01

    Current technology makes it possible to display navigation and terrain information on electronic : screens in the cockpit. The conventions used for position and terrain information must be clearly : presented so pilots can maintain their positional a...

  9. The effects of spectral tuning of evening ambient light on melatonin suppression, alertness and sleep.

    PubMed

    Rahman, Shadab A; St Hilaire, Melissa A; Lockley, Steven W

    2017-08-01

    We compared the effects of bedroom-intensity light from a standard fluorescent and a blue- (i.e., short-wavelength) depleted LED source on melatonin suppression, alertness, and sleep. Sixteen healthy participants (8 females) completed a 4-day inpatient study. Participants were exposed to blue-depleted circadian-sensitive (C-LED) light and a standard fluorescent light (FL, 4100K) of equal illuminance (50lx) for 8h prior to a fixed bedtime on two separate days in a within-subject, randomized, cross-over design. Each light exposure day was preceded by a dim light (<3lx) control at the same time 24h earlier. Compared to the FL condition, control-adjusted melatonin suppression was significantly reduced. Although subjective sleepiness was not different between the two light conditions, auditory reaction times were significantly slower under C-LED conditions compared to FL 30min prior to bedtime. EEG-based correlates of alertness corroborated the reduced alertness under C-LED conditions as shown by significantly increased EEG spectral power in the delta-theta (0.5-8.0Hz) bands under C-LED as compared to FL exposure. There was no significant difference in total sleep time (TST), sleep efficiency (SE%), and slow-wave activity (SWA) between the two conditions. Unlike melatonin suppression and alertness, a significant order effect was observed on all three sleep variables, however. Individuals who received C-LED first and then FL had increased TST, SE% and SWA averaged across both nights compared to individuals who received FL first and then C-LED. These data show that the spectral characteristics of light can be fine-tuned to attenuate non-visual responses to light in humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Practical results from a mathematical analysis of guard patrols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Indusi, Joseph P.

    1978-12-01

    Using guard patrols as a primary detection mechanism is not generally viewed as a highly efficient detection method when compared to electronic means. Many factors such as visibility, alertness, and the space-time coincidence of guard and adversary presence all have an effect on the probability of detection. Mathematical analysis of the guard patrol detection problem is related to that of classical search theory originally developed for naval search operations. The results of this analysis tend to support the current practice of using guard forces to assess and respond to previously detected intrusions and not as the primary detection mechanism. 6more » refs.« less

  11. Intense illumination in the morning hours improved mood and alertness but not mental performance.

    PubMed

    Leichtfried, Veronika; Mair-Raggautz, Maria; Schaeffer, Viktoria; Hammerer-Lercher, Angelika; Mair, Gerald; Bartenbach, Christian; Canazei, Markus; Schobersberger, Wolfgang

    2015-01-01

    Cognitive performance and alertness are two determinants for work efficiency, varying throughout the day and depending on bright light. We conducted a prospective crossover study evaluating the impacts of exposure to an intense, early morning illumination on sustained attention, alertness, mood, and serum melatonin levels in 33 healthy individuals. Compared with a dim illumination, the intense illumination negatively impacted performance requiring sustained attention; however, it positively impacted subjective alertness and mood and had no impact on serum melatonin levels. These results suggest that brief exposure to bright light in the morning hours can improve subjective measures of mood and alertness, but can also have detrimental effects on mental performance as a result of visual distraction. Therefore, it is important that adequate lighting should correspond to both non-visual and visual demands. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Randomized Trial of a Health Coaching Intervention to Enhance Retention in Care: California Collaborative Treatment Group 594.

    PubMed

    Corado, Katya; Jain, Sonia; Morris, Sheldon; Dube, Michael P; Daar, Eric S; He, Feng; Aldous, Jeannette L; Sitapati, Amy; Haubrich, Richard; Milam, Joel; Karris, Maile Young

    2018-05-03

    Poor linkage, engagement and retention remain significant barriers in achieving HIV treatment goals in the US. HIV-infected persons entering or re-entering care across three Southern California academic HIV clinics, were randomized (1:1) to an Active, Linkage, Engagement, Retention and Treatment (ALERT) specialist for outreach and health coaching, or standard of care (SOC). The primary outcome of time to loss to follow up (LTFU) was compared using Cox proportional hazards regression modeling. No differences in the median time to LTFU (81.7 for ALERT versus 93.6 weeks for SOC; HR 1.27; p = 0.40), or time to ART initiation was observed (N = 116). Although, ALERT participants demonstrated worsening depressive symptomatology from baseline to week 48 compared to SOC (p = 0.02). The ALERT intervention did not improve engagement and retention in HIV care over SOC. Further studies are needed to determine how best to apply resources to improve retention and engagement.

  13. Sleep and Alertness in Medical Interns and Residents: An Observational Study on the Role of Extended Shifts.

    PubMed

    Basner, Mathias; Dinges, David F; Shea, Judy A; Small, Dylan S; Zhu, Jingsan; Norton, Laurie; Ecker, Adrian J; Novak, Cristina; Bellini, Lisa M; Volpp, Kevin G

    2017-04-01

    Fatigue from sleep loss is a risk to physician and patient safety, but objective data on physician sleep and alertness on different duty hour schedules is scarce. This study objectively quantified differences in sleep duration and alertness between medical interns working extended overnight shifts and residents not or rarely working extended overnight shifts. Sleep-wake activity of 137 interns and 87 PGY-2/3 residents on 2-week Internal Medicine and Oncology rotations was assessed with wrist-actigraphy. Alertness was assessed daily with a brief Psychomotor Vigilance Test (PVT) and the Karolinska Sleepiness Scale. Interns averaged 6.93 hours (95% confidence interval [CI] 6.84-7.03 hours) sleep per 24 hours across shifts, significantly less than residents not working overnight shifts (7.18 hours, 95% CI 7.06-7.30 hours, p = .007). Interns obtained on average 2.19 hours (95% CI 2.02-2.36 hours) sleep during on-call nights (17.5% obtained no sleep). Alertness was significantly lower on mornings after on-call nights compared to regular shifts (p < .001). Naps between 9 am and 6 pm on the first day post-call were frequent (90.8%) and averaged 2.84 hours (95% CI 2.69-3.00 hours), but interns still slept 1.66 hours less per 24 hours (95% CI 1.56-1.76 hours) compared to regular shift days (p < .001). Sleep inertia significantly affected alertness in the 60 minutes after waking on-call. Extended overnight shifts increase the likelihood of chronic sleep restriction in interns. Reduced levels of alertness after on-call nights need to be mitigated. A systematic comparison of sleep, alertness, and safety outcomes under current and past duty hour rules is encouraged. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  14. Sleep and Alertness in Medical Interns and Residents: An Observational Study on the Role of Extended Shifts

    PubMed Central

    Dinges, David F.; Shea, Judy A.; Small, Dylan S.; Zhu, Jingsan; Norton, Laurie; Ecker, Adrian J.; Novak, Cristina; Bellini, Lisa M.; Volpp, Kevin G.

    2017-01-01

    Abstract Study Objectives: Fatigue from sleep loss is a risk to physician and patient safety, but objective data on physician sleep and alertness on different duty hour schedules is scarce. This study objectively quantified differences in sleep duration and alertness between medical interns working extended overnight shifts and residents not or rarely working extended overnight shifts. Methods: Sleep–wake activity of 137 interns and 87 PGY-2/3 residents on 2-week Internal Medicine and Oncology rotations was assessed with wrist-actigraphy. Alertness was assessed daily with a brief Psychomotor Vigilance Test (PVT) and the Karolinska Sleepiness Scale. Results: Interns averaged 6.93 hours (95% confidence interval [CI] 6.84–7.03 hours) sleep per 24 hours across shifts, significantly less than residents not working overnight shifts (7.18 hours, 95% CI 7.06–7.30 hours, p = .007). Interns obtained on average 2.19 hours (95% CI 2.02–2.36 hours) sleep during on-call nights (17.5% obtained no sleep). Alertness was significantly lower on mornings after on-call nights compared to regular shifts (p < .001). Naps between 9 am and 6 pm on the first day post‐call were frequent (90.8%) and averaged 2.84 hours (95% CI 2.69–3.00 hours), but interns still slept 1.66 hours less per 24 hours (95% CI 1.56–1.76 hours) compared to regular shift days (p < .001). Sleep inertia significantly affected alertness in the 60 minutes after waking on-call. Conclusions: Extended overnight shifts increase the likelihood of chronic sleep restriction in interns. Reduced levels of alertness after on-call nights need to be mitigated. A systematic comparison of sleep, alertness, and safety outcomes under current and past duty hour rules is encouraged. PMID:28329124

  15. Improving the Health Forecasting Alert System for Cold Weather and Heat-Waves In England: A Proof-of-Concept Using Temperature-Mortality Relationships

    PubMed Central

    Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia

    2015-01-01

    Objectives In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office’s (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. Method The prototype health forecasting alert system introduces an “impact vs likelihood matrix” for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. Conclusions The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use. PMID:26431427

  16. Improving the Health Forecasting Alert System for Cold Weather and Heat-Waves In England: A Proof-of-Concept Using Temperature-Mortality Relationships.

    PubMed

    Masato, Giacomo; Bone, Angie; Charlton-Perez, Andrew; Cavany, Sean; Neal, Robert; Dankers, Rutger; Dacre, Helen; Carmichael, Katie; Murray, Virginia

    2015-01-01

    In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.

  17. Effects of an air pollution personal alert system on health service usage in a high-risk general population: a quasi-experimental study using linked data.

    PubMed

    Lyons, R A; Rodgers, S E; Thomas, S; Bailey, R; Brunt, H; Thayer, D; Bidmead, J; Evans, B A; Harold, P; Hooper, M; Snooks, H

    2016-05-23

    There is no evidence to date on whether an intervention alerting people to high levels of pollution is effective in reducing health service utilisation. We evaluated alert accuracy and the effect of a targeted personal air pollution alert system, airAware, on emergency hospital admissions, emergency department attendances, general practitioner contacts and prescribed medications. Quasi-experimental study describing accuracy of alerts compared with pollution triggers; and comparing relative changes in healthcare utilisation in the intervention group to those who did not sign-up. Participants were people diagnosed with asthma, chronic obstructive pulmonary disease (COPD) or coronary heart disease, resident in an industrial area of south Wales and registered patients at 1 of 4 general practices. Longitudinal anonymised record linked data were modelled for participants and non-participants, adjusting for differences between groups. During the 2-year intervention period alerts were correctly issued on 208 of 248 occasions; sensitivity was 83.9% (95% CI 78.8% to 87.9%) and specificity 99.5% (95% CI 99.3% to 99.6%). The intervention was associated with a 4-fold increase in admissions for respiratory conditions (incidence rate ratio (IRR) 3.97; 95% CI 1.59 to 9.93) and a near doubling of emergency department attendance (IRR=1.89; 95% CI 1.34 to 2.68). The intervention was associated with increased emergency admissions for respiratory conditions. While findings may be context specific, evidence from this evaluation questions the benefits of implementing near real-time personal pollution alert systems for high-risk individuals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. An Analysis of EMS and ED Detection of Stroke.

    PubMed

    Medoro, Ian; Cone, David C

    2017-01-01

    Studies have shown a reduction in time-to-CT and improved process measures when EMS personnel notify the ED of a "stroke alert" from the field. However, there are few data on the accuracy of these EMS stroke alerts. The goal of this study was to examine diagnostic test performance of EMS and ED stroke alerts and related process measures. The EMS and ED records of all stroke alerts in a large tertiary ED from August 2013-January 2014 were examined and data abstracted by one trained investigator, with data accuracy confirmed by a second investigator for 15% of cases. Stroke alerts called by EMS prior to ED arrival were compared to stroke alerts called by ED physicians and nurses (for walk-in patients, and patients transported by EMS without EMS stroke alerts). Means ± SD, medians, unpaired t-tests (for continuous data), and two-tailed Fisher's exact tests (for categorical data) were used. Of 260 consecutive stroke alerts, 129 were EMS stroke alerts, and 131 were ED stroke alerts (70 called by physicians, 61 by nurses). The mean NIH Stroke Scale was higher in the EMS group (8.1 ± 7.6 vs. 3.0 ± 5.0, p < 0.0001). The positive predictive value of EMS stroke alerts was 0.60 (78/129), alerts by ED nurses was 0.25 (15/61), and alerts by ED physicians was 0.31 (22/70). The PPV for EMS was better than for nurses or physicians (both p < 0.001), and more patients in the EMS group had final diagnoses of stroke (62/129 vs. 24/131, p < 0.001). The positive likelihood ratio was 1.53 for EMS personnel, 0.45 for physicians, and 0.77 for nurses. The mean time to order the CT (8.5 ± 7.1 min vs. 23.1 ± 18.2 min, p < 0.0001) and the mean ED length of stay (248 ± 116 min vs. 283 ± 128 min, p = 0.022) were shorter for the EMS stroke alert group. More EMS stroke alert patients received tPA (16/129 vs. 6/131, p = 0.027). EMS stroke alerts have better diagnostic test performance than stroke alerts by ED staff, likely due to higher NIH Stroke Scale scores (more obvious presentations) and are associated with better process measures. The fairly low PPV suggests room for improvement in prehospital stroke protocols.

  19. A graphical workstation based part-task flight simulator for preliminary rapid evaluation of advanced displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Kuchar, James; Hahn, Edward; Pritchett, Amy; Hansman, R. J.

    1992-01-01

    Advances in avionics and display technology are significantly changing the cockpit environment in current transport aircraft. The MIT Aeronautical Systems Lab (ASL) has developed a part-task flight simulator specifically to study the effects of these new technologies on flight crew situational awareness and performance. The simulator is based on a commercially-available graphics workstation, and can be rapidly reconfigured to meet the varying demands of experimental studies. The simulator has been successfully used to evaluate graphical microburst alerting displays, electronic instrument approach plates, terrain awareness and alerting displays, and ATC routing amendment delivery through digital datalinks.

  20. Improving the health forecasting alert system for cold weather and heat-waves in England: a case-study approach using temperature-mortality relationships

    NASA Astrophysics Data System (ADS)

    Masato, Giacomo; Cavany, Sean; Charlton-Perez, Andrew; Dacre, Helen; Bone, Angie; Carmicheal, Katie; Murray, Virginia; Danker, Rutger; Neal, Rob; Sarran, Christophe

    2015-04-01

    The health forecasting alert system for cold weather and heatwaves currently in use in the Cold Weather and Heatwave plans for England is based on 5 alert levels, with levels 2 and 3 dependent on a forecast or actual single temperature action trigger. Epidemiological evidence indicates that for both heat and cold, the impact on human health is gradual, with worsening impact for more extreme temperatures. The 60% risk of heat and cold forecasts used by the alerts is a rather crude probabilistic measure, which could be substantially improved thanks to the state-of-the-art forecast techniques. In this study a prototype of a new health forecasting alert system is developed, which is aligned to the approach used in the Met Office's (MO) National Severe Weather Warning Service (NSWWS). This is in order to improve information available to responders in the health and social care system by linking temperatures more directly to risks of mortality, and developing a system more coherent with other weather alerts. The prototype is compared to the current system in the Cold Weather and Heatwave plans via a case-study approach to verify its potential advantages and shortcomings. The prototype health forecasting alert system introduces an "impact vs likelihood matrix" for the health impacts of hot and cold temperatures which is similar to those used operationally for other weather hazards as part of the NSWWS. The impact axis of this matrix is based on existing epidemiological evidence, which shows an increasing relative risk of death at extremes of outdoor temperature beyond a threshold which can be identified epidemiologically. The likelihood axis is based on a probability measure associated with the temperature forecast. The new method is tested for two case studies (one during summer 2013, one during winter 2013), and compared to the performance of the current alert system. The prototype shows some clear improvements over the current alert system. It allows for a much greater degree of flexibility, provides more detailed regional information about the health risks associated with periods of extreme temperatures, and is more coherent with other weather alerts which may make it easier for front line responders to use. It will require validation and engagement with stakeholders before it can be considered for use.

  1. Investigating the contribution of short wavelengths in the alerting effect of bright light.

    PubMed

    Sasseville, Alexandre; Martin, Jeanne Sophie; Houle, Jérôme; Hébert, Marc

    2015-11-01

    Short-wavelengths can have an acute impact on alertness, which is allegedly due to their action on intrinsically photosensitive retinal ganglion cells. Classical photoreceptors cannot, however, be excluded at this point in time as contributors to the alerting effect of light. The objective of this study was to compare the alerting effect at night of a white LED light source while wearing blue-blockers or not, in order to establish the contribution of short-wavelengths. 20 participants stayed awake under dim light (< 5 lx) from 23:00 h to 04:00 h on two consecutive nights. On the second night, participants were randomly assigned to one light condition for 30 min starting at 3:00 h. Group A (5M/5F) was exposed to 500 μW/cm(2) of unfiltered LED light, while group B (4M/6F) was required to wear blue-blocking glasses, while exposed to 1500 μW/cm(2) from the same light device in order to achieve 500 μW/cm(2) at eye level (as measured behind the glasses). Subjective alertness, energy, mood and anxiety were assessed for both nights at 23:30 h, 01:30 h and 03:30 h using a visual analog scale (VAS). Subjective sleepiness was assessed with the Stanford Sleepiness Scale (SSS). Subjects also performed the Conners' Continuous Performance Test II (CPT-II) in order to assess objective alertness. Mixed model analysis was used to compare VAS, SSS and CPT-II parameters. No difference between group A and group B was observed for subjective alertness, energy, mood, anxiety and sleepiness, as well as CPT-II parameters. Subjective alertness (p < 0.001), energy (p < 0.001) and sleepiness (p < 0.05) were, however improved after light exposure on the second night independently of the light condition. The current study shows that when sleepiness is high, the alerting effect of light can still be triggered at night in the absence of short-wavelengths with a 30 minute light pulse of 500 μW/cm(2). This suggests that the underlying mechanism by which a brief polychromatic light exposure improves alertness is not solely due to short-wavelengths through intrinsically photosensitive retinal ganglion cells.

  2. Tactical Conflict Detection in Terminal Airspace

    NASA Technical Reports Server (NTRS)

    Tang, Huabin; Robinson, John E.; Denery, Dallas G.

    2010-01-01

    Air traffic systems have long relied on automated short-term conflict prediction algorithms to warn controllers of impending conflicts (losses of separation). The complexity of terminal airspace has proven difficult for such systems as it often leads to excessive false alerts. Thus, the legacy system, called Conflict Alert, which provides short-term alerts in both en-route and terminal airspace currently, is often inhibited or degraded in areas where frequent false alerts occur, even though the alerts are provided only when an aircraft is in dangerous proximity of other aircraft. This research investigates how a minimal level of flight intent information may be used to improve short-term conflict detection in terminal airspace such that it can be used by the controller to maintain legal aircraft separation. The flight intent information includes a site-specific nominal arrival route and inferred altitude clearances in addition to the flight plan that includes the RNAV (Area Navigation) departure route. A new tactical conflict detection algorithm is proposed, which uses a single analytic trajectory, determined by the flight intent and the current state information of the aircraft, and includes a complex set of current, dynamic separation standards for terminal airspace to define losses of separation. The new algorithm is compared with an algorithm that imitates a known en-route algorithm and another that imitates Conflict Alert by analysis of false-alert rate and alert lead time with recent real-world data of arrival and departure operations and a large set of operational error cases from Dallas/Fort Worth TRACON (Terminal Radar Approach Control). The new algorithm yielded a false-alert rate of two per hour and an average alert lead time of 38 seconds.

  3. Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

    PubMed

    Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Sanguinetti, Maurizio; Spanu, Teresa

    2014-10-01

    We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥ 16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤ 5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization-time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  4. Timely Follow-Up of Abnormal Diagnostic Imaging Test Results in an Outpatient Setting: Are Electronic Medical Records Achieving Their Potential?

    PubMed Central

    Singh, Hardeep; Thomas, Eric J.; Mani, Shrinidi; Sittig, Dean; Arora, Harvinder; Espadas, Donna; Khan, Myrna M.; Petersen, Laura A.

    2010-01-01

    Background Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic test results remains a challenge. We hypothesized that an EMR that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. Methods We studied critical imaging alert notifications in the outpatient setting of a tertiary care VA facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (i.e. provider opened the message for viewing) within two weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted providers to determine timely follow-up actions (e.g. ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by providers analyzed predictors for two outcomes; lack of acknowledgment and lack of timely follow-up. Results Of 123,638 studies (including X-rays, CT scans, ultrasounds, MRI and mammography), 1196 (0.97%) images generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when ordering providers were trainees (OR, 5.58;95%CI, 2.86-10.89) and when dual (more than one provider alerted) as opposed to single communication was used (OR, 2.02;95%CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs. 9.7%;p=0.2). Risk for lack of timely follow-up was higher with dual communication (OR,1.99;95%CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12;95%CI: 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. Conclusions Critical imaging results may not receive timely follow-up actions even when providers receive and read results in an advanced, integrated EMR system. A multidisciplinary approach is needed to improve patient safety in this area. PMID:19786677

  5. Antimicrobial Stewardship in a Community Hospital: Attacking the More Difficult Problems

    PubMed Central

    Philmon, Carla L.; Johnson, Gregory D.; Ward, William S.; Rivers, LaToya L.; Williamson, Sharon A.; Goodman, Edward L.

    2014-01-01

    Background: Antibiotic stewardship has been proposed as an important way to reduce or prevent antibiotic resistance. In 2001, a community hospital implemented an antimicrobial management program. It was successful in reducing antimicrobial utilization and expenditure. In 2011, with the implementation of a data-mining tool, the program was expanded and its focus transitioned from control of antimicrobial use to guiding judicious antimicrobial prescribing. Objective: To test the hypothesis that adding a data-mining tool to an existing antimicrobial stewardship program will further increase appropriate use of antimicrobials. Design: Interventional study with historical comparison. Methods: Rules and alerts were built into the data-mining tool to aid in identifying inappropriate antibiotic utilization. Decentralized pharmacists acted on alerts for intravenous (IV) to oral conversion, perioperative antibiotic duration, and restricted antimicrobials. An Infectious Diseases (ID) Pharmacist and ID Physician/Hospital Epidemiologist focused on all other identified alert types such as antibiotic de-escalation, bug-drug mismatch, and double coverage. Electronic chart notes and phone calls to physicians were utilized to make recommendations. Results: During 2012, 2,003 antimicrobial interventions were made with a 90% acceptance rate. Targeted broad-spectrum antimicrobial use decreased by 15% in 2012 compared to 2010, which represented cost savings of $1,621,730. There were no statistically significant changes in antimicrobial resistance, and no adverse patient outcomes were noted. Conclusions: The addition of a data-mining tool to an antimicrobial stewardship program can further decrease inappropriate use of antimicrobials, provide a greater reduction in overall antimicrobial use, and provide increased cost savings without negatively affecting patient outcomes. PMID:25477615

  6. Potholes on the Infobahn: Hazardous Conditions Ahead?

    ERIC Educational Resources Information Center

    Laughon, Sally; Hanson, William R.

    1996-01-01

    Alerts educators to potentially objectionable Internet materials. Electronic mail, newsgroups, file transfer protocol sites, Internet Relay Chat (IRC), Multiuser Dungeons (MUDs), and Multiuser Object Oriented (MOOs) are services whose user anonymity can embolden discussions regarding sex, prejudice, religious dogma, and gambling. Teachers may wish…

  7. Speech Auditory Alerts Promote Memory for Alerted Events in a Video-Simulated Self-Driving Car Ride.

    PubMed

    Nees, Michael A; Helbein, Benji; Porter, Anna

    2016-05-01

    Auditory displays could be essential to helping drivers maintain situation awareness in autonomous vehicles, but to date, few or no studies have examined the effectiveness of different types of auditory displays for this application scenario. Recent advances in the development of autonomous vehicles (i.e., self-driving cars) have suggested that widespread automation of driving may be tenable in the near future. Drivers may be required to monitor the status of automation programs and vehicle conditions as they engage in secondary leisure or work tasks (entertainment, communication, etc.) in autonomous vehicles. An experiment compared memory for alerted events-a component of Level 1 situation awareness-using speech alerts, auditory icons, and a visual control condition during a video-simulated self-driving car ride with a visual secondary task. The alerts gave information about the vehicle's operating status and the driving scenario. Speech alerts resulted in better memory for alerted events. Both auditory display types resulted in less perceived effort devoted toward the study tasks but also greater perceived annoyance with the alerts. Speech auditory displays promoted Level 1 situation awareness during a simulation of a ride in a self-driving vehicle under routine conditions, but annoyance remains a concern with auditory displays. Speech auditory displays showed promise as a means of increasing Level 1 situation awareness of routine scenarios during an autonomous vehicle ride with an unrelated secondary task. © 2016, Human Factors and Ergonomics Society.

  8. Supporting the patient's role in guideline compliance: a controlled study.

    PubMed

    Rosenberg, Stephen N; Shnaiden, Tatiana L; Wegh, Arnold A; Juster, Iver A

    2008-11-01

    Clinical messages alerting physicians to gaps in the care of specific patients have been shown to increase compliance with evidence-based guidelines. This study sought to measure any additional impact on compliance when alerting messages also were sent to patients. For alerts that were generated by computerized clinical rules applied to claims, compliance was determined by subsequent claims evidence (eg, that recommended tests were performed). Compliance was measured in the baseline year and the study year for 4 study group employers (combined membership >100,000) that chose to add patient messaging in the study year, and 28 similar control group employers (combined membership >700,000) that maintained physician messaging but did not add patient messaging. The impact of patient messaging was assessed by comparing changes in compliance from baseline to study year in the 2 groups. Multiple logistic regression was used to control for differences between the groups. Because a given member or physician could receive multiple alerts, generalized estimating equations with clustering by patient and physician were used. Controlling for differences in age, sex, and the severity and types of clinical alerts between the study and control groups, the addition of patient messaging increased compliance by 12.5% (P <.001). This increase was primarily because of improved responses to alerts regarding the need for screening, diagnostic, and monitoring tests. Supplementing clinical alerts to physicians with messages directly to their patients produced a statistically significant increase in compliance with the evidence-based guidelines underlying the alerts.

  9. The Alert Collector. Workplace Violence: Information Sources.

    ERIC Educational Resources Information Center

    Lewis, Janice S., Ed.; Stankus, Tony, Ed.

    1995-01-01

    Discusses workplace violence with a focus on disgruntled employees and library violence; reviews recent reports and recommended training. Highlights include workplace violence in general and violence in libraries. An annotated bibliography on workplace violence includes print indexes; electronic resources; journals and newsletters; and videotapes.…

  10. Weather-based prediction of Plasmodium falciparum malaria in epidemic-prone regions of Ethiopia II. Weather-based prediction systems perform comparably to early detection systems in identifying times for interventions.

    PubMed

    Teklehaimanot, Hailay D; Schwartz, Joel; Teklehaimanot, Awash; Lipsitch, Marc

    2004-11-19

    Timely and accurate information about the onset of malaria epidemics is essential for effective control activities in epidemic-prone regions. Early warning methods that provide earlier alerts (usually by the use of weather variables) may permit control measures to interrupt transmission earlier in the epidemic, perhaps at the expense of some level of accuracy. Expected case numbers were modeled using a Poisson regression with lagged weather factors in a 4th-degree polynomial distributed lag model. For each week, the numbers of malaria cases were predicted using coefficients obtained using all years except that for which the prediction was being made. The effectiveness of alerts generated by the prediction system was compared against that of alerts based on observed cases. The usefulness of the prediction system was evaluated in cold and hot districts. The system predicts the overall pattern of cases well, yet underestimates the height of the largest peaks. Relative to alerts triggered by observed cases, the alerts triggered by the predicted number of cases performed slightly worse, within 5% of the detection system. The prediction-based alerts were able to prevent 10-25% more cases at a given sensitivity in cold districts than in hot ones. The prediction of malaria cases using lagged weather performed well in identifying periods of increased malaria cases. Weather-derived predictions identified epidemics with reasonable accuracy and better timeliness than early detection systems; therefore, the prediction of malarial epidemics using weather is a plausible alternative to early detection systems.

  11. Light at Night and Measures of Alertness and Performance: Implications for Shift Workers.

    PubMed

    Figueiro, Mariana G; Sahin, Levent; Wood, Brittany; Plitnick, Barbara

    2016-01-01

    Rotating-shift workers, particularly those working at night, are likely to experience sleepiness, decreased productivity, and impaired safety while on the job. Light at night has been shown to have acute alerting effects, reduce sleepiness, and improve performance. However, light at night can also suppress melatonin and induce circadian disruption, both of which have been linked to increased health risks. Previous studies have shown that long-wavelength (red) light exposure increases objective and subjective measures of alertness at night, without suppressing nocturnal melatonin. This study investigated whether exposure to red light at night would not only increase measures of alertness but also improve performance. It was hypothesized that exposure to both red (630 nm) and white (2,568 K) lights would improve performance but that only white light would significantly affect melatonin levels. Seventeen individuals participated in a 3-week, within-subjects, nighttime laboratory study. Compared to remaining in dim light, participants had significantly faster reaction times in the GO/NOGO test after exposure to both red light and white light. Compared to dim light exposure, power in the alpha and alpha-theta regions was significantly decreased after exposure to red light. Melatonin levels were significantly suppressed by white light only. Results show that not only can red light improve measures of alertness, but it can also improve certain types of performance at night without affecting melatonin levels. These findings could have significant practical applications for nurses; red light could help nurses working rotating shifts maintain nighttime alertness, without suppressing melatonin or changing their circadian phase. © The Author(s) 2015.

  12. A Comparative Analysis of the Snort and Suricata Intrusion-Detection Systems

    DTIC Science & Technology

    2011-09-01

    Category: Test Rules Test #6: Simple LFI Attack 43 Snort True Positive: Snort generated an alert based on the ‘/etc/ passwd ’ string passed...through an HTTP command. Suricata True Positive: Suricata generated an alert based on the ‘/etc/ passwd ’ string passed through an HTTP command

  13. Some effects of 8- vs 10-hour work schedules on the test performance/alertness of air traffic control specialists.

    DOT National Transportation Integrated Search

    1995-12-01

    A 10-hour, 4-day rotating shift schedule worked by some Air Traffic Control Specialists (ATCSs) was compared to the more traditional 8-hour, 2-2-1 rapidly rotating schedule. Measures of performance and alertness were obtained from a group of 52 ATCSs...

  14. Phasic alertness cues modulate visual processing speed in healthy aging.

    PubMed

    Haupt, Marleen; Sorg, Christian; Napiórkowski, Natan; Finke, Kathrin

    2018-05-31

    Warning signals temporarily increase the rate of visual information in younger participants and thus optimize perception in critical situations. It is unclear whether such important preparatory processes are preserved in healthy aging. We parametrically assessed the effects of auditory alertness cues on visual processing speed and their time course using a whole report paradigm based on the computational Theory of Visual Attention. We replicated prior findings of significant alerting benefits in younger adults. In conditions with short cue-target onset asynchronies, this effect was baseline-dependent. As younger participants with high baseline speed did not show a profit, an inverted U-shaped function of phasic alerting and visual processing speed was implied. Older adults also showed a significant cue-induced benefit. Bayesian analyses indicated that the cueing benefit on visual processing speed was comparably strong across age groups. Our results indicate that in aging individuals, comparable to younger ones, perception is active and increased expectancy of the appearance of a relevant stimulus can increase the rate of visual information uptake. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Device Would Monitor Body Parameters Continuously

    NASA Technical Reports Server (NTRS)

    Cook, Joseph S., Jr.

    1995-01-01

    Proposed miniature electronic circuit continuously measures temperature of human subject. Once mounted on subject's skin with medical adhesive tape, electronic thermometer remains in thermal equilibrium with subject's body; thereafter, no need to wait until thermometer reaches body temperature before taking reading. Design provides for switches used to set alarm alerting medical attendants if subject's temperature exceeds critical level. For use on very young child, electronic thermometer sewed into shirt or other suitable garment; device held in contact with skin, and child could not swallow it. Replacement of sensor and computing algorithm changes temperature monitor to cardiorespiratory monitor.

  16. Biometric Border Security Evaluation Framework (Biometrique Cadre D’evaluation de la Securite des Frontieres)

    DTIC Science & Technology

    2011-10-01

    those least likely to change significantly over time: upper ridges of the eye sockets, areas around the cheekbones, sides of the mouth , nose shape, and...conduct self-process using their electronic passports. ACS processes roughly 22 million visitors annually in airport environments. The program was...the electronic passport. A successful match permits a traveler to clear through the customs control point, whereas an unsuccessful match alerts the

  17. Performance of the BacT Alert 3D System Versus Solid Media for Recovery and Drug Susceptibility Testing of Mycobacterium tuberculosis in a Tertiary Hospital in Korea.

    PubMed

    Kim, Seoung-Cheol; Jeon, Bo-Young; Kim, Jin-Sook; Choi, In Hwan; Kim, Jiro; Woo, Jeongim; Kim, Soojin; Lee, Hyeong Woo; Sezim, Monoldorova; Cho, Sang-Nae

    2016-10-01

    Tuberculosis (TB) is a major health problem, and accurate and rapid diagnosis of multidrug-resistant (MDR) and extended drug-resistant (XDR) TB is important for appropriate treatment. In this study, performances of solid and liquid culture methods were compared with respect to MDR- and XDR-TB isolate recovery and drug susceptibility testing. Sputum specimens from 304 patients were stained with Ziehl-Neelsen method. Mycobacterium tuberculosis (Mtb) isolates were tested for recovery on Löwenstein-Jensen (LJ) medium and the BacT Alert 3D system. For drug susceptibility testing of Mtb, isolates were evaluated on M-KIT plates and the BacT Alert 3D system. The recovery rates were 94.9% (206/217) and 98.2% (213/217) for LJ medium and the BacT Alert 3D system, respectively (kappa coefficient, 0.884). The rate of drug resistance was 13.4% for at least one or more drugs, 6.0% for MDR-TB and 2.3% for XDR-TB. M-KIT plate and BacT 3D Alert 3D system were comparable in drug susceptibility testing for isoniazid (97.7%; kappa coefficient, 0.905) and rifampin (98.6%; kappa coefficient, 0.907). Antibiotic resistance was observed using M-KIT plates for 24 of the total 29 Mtb isolates (82.8%). The liquid culture system showed greater reduction in the culture period, as compared with LJ medium; however, drug susceptibility testing using M-KIT plates was advantageous for simultaneous testing against multiple drug targets.

  18. Case-Based Multi-Sensor Intrusion Detection

    NASA Astrophysics Data System (ADS)

    Schwartz, Daniel G.; Long, Jidong

    2009-08-01

    Multi-sensor intrusion detection systems (IDSs) combine the alerts raised by individual IDSs and possibly other kinds of devices such as firewalls and antivirus software. A critical issue in building a multi-sensor IDS is alert-correlation, i.e., determining which alerts are caused by the same attack. This paper explores a novel approach to alert correlation using case-based reasoning (CBR). Each case in the CBR system's library contains a pattern of alerts raised by some known attack type, together with the identity of the attack. Then during run time, the alert streams gleaned from the sensors are compared with the patterns in the cases, and a match indicates that the attack described by that case has occurred. For this purpose the design of a fast and accurate matching algorithm is imperative. Two such algorithms were explored: (i) the well-known Hungarian algorithm, and (ii) an order-preserving matching of our own device. Tests were conducted using the DARPA Grand Challenge Problem attack simulator. These showed that the both matching algorithms are effective in detecting attacks; but the Hungarian algorithm is inefficient; whereas the order-preserving one is very efficient, in fact runs in linear time.

  19. Acute alerting effects of light: A systematic literature review.

    PubMed

    Souman, Jan L; Tinga, Angelica M; Te Pas, Susan F; van Ee, Raymond; Vlaskamp, Björn N S

    2018-01-30

    Periodic, well timed exposure to light is important for our health and wellbeing. Light, in particular in the blue part of the spectrum, is thought to affect alertness both indirectly, by modifying circadian rhythms, and directly, giving rise to acute effects. We performed a systematic review of empirical studies on direct, acute effects of light on alertness to evaluate the reliability of these effects. In total, we identified 68 studies in which either light intensity, spectral distribution, or both were manipulated, and evaluated the effects on behavioral measures of alertness, either subjectively or measured in reaction time performance tasks. The results show that increasing the intensity of polychromatic white light has been found to increase subjective ratings of alertness in a majority of studies, though a substantial proportion of studies failed to find significant effects, possibly due to small sample sizes or high baseline light intensities. The effect of the color temperature of white light on subjective alertness is less clear. Some studies found increased alertness with higher color temperatures, but other studies reported no detrimental effects of filtering out the short wavelengths from the spectrum. Similarly, studies that used monochromatic light exposure showed no systematic pattern for the effects of blue light compared to longer wavelengths. Far fewer studies investigated the effects of light intensity or spectrum on alertness as measured with reaction time tasks and of those, very few reported significant effects. In general, the small sample sizes used in studies on acute alerting effects of light make it difficult to draw definitive conclusions and better powered studies are needed, especially studies that allow for the construction of dose-response curves. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. AMON: Transition to real-time operations

    NASA Astrophysics Data System (ADS)

    Cowen, D. F.; Keivani, A.; Tešić, G.

    2016-04-01

    The Astrophysical Multimessenger Observatory Network (AMON) will link the world's leading high-energy neutrino, cosmic-ray, gamma-ray and gravitational wave observatories by performing real-time coincidence searches for multimessenger sources from observatories' subthreshold data streams. The resulting coincidences will be distributed to interested parties in the form of electronic alerts for real-time follow-up observation. We will present the science case, design elements, current and projected partner observatories, status of the AMON project, and an initial AMON-enabled analysis. The prototype of the AMON server has been online since August 2014 and processing archival data. Currently, we are deploying new high-uptime servers and will be ready to start issuing alerts as early as winter 2015/16.

  1. Earthquake Early Warning ShakeAlert System: Testing and certification platform

    USGS Publications Warehouse

    Cochran, Elizabeth S.; Kohler, Monica D.; Given, Douglas; Guiwits, Stephen; Andrews, Jennifer; Meier, Men-Andrin; Ahmad, Mohammad; Henson, Ivan; Hartog, Renate; Smith, Deborah

    2017-01-01

    Earthquake early warning systems provide warnings to end users of incoming moderate to strong ground shaking from earthquakes. An earthquake early warning system, ShakeAlert, is providing alerts to beta end users in the western United States, specifically California, Oregon, and Washington. An essential aspect of the earthquake early warning system is the development of a framework to test modifications to code to ensure functionality and assess performance. In 2016, a Testing and Certification Platform (TCP) was included in the development of the Production Prototype version of ShakeAlert. The purpose of the TCP is to evaluate the robustness of candidate code that is proposed for deployment on ShakeAlert Production Prototype servers. TCP consists of two main components: a real‐time in situ test that replicates the real‐time production system and an offline playback system to replay test suites. The real‐time tests of system performance assess code optimization and stability. The offline tests comprise a stress test of candidate code to assess if the code is production ready. The test suite includes over 120 events including local, regional, and teleseismic historic earthquakes, recentering and calibration events, and other anomalous and potentially problematic signals. Two assessments of alert performance are conducted. First, point‐source assessments are undertaken to compare magnitude, epicentral location, and origin time with the Advanced National Seismic System Comprehensive Catalog, as well as to evaluate alert latency. Second, we describe assessment of the quality of ground‐motion predictions at end‐user sites by comparing predicted shaking intensities to ShakeMaps for historic events and implement a threshold‐based approach that assesses how often end users initiate the appropriate action, based on their ground‐shaking threshold. TCP has been developed to be a convenient streamlined procedure for objectively testing algorithms, and it has been designed with flexibility to accommodate significant changes in development of new or modified system code. It is expected that the TCP will continue to evolve along with the ShakeAlert system, and the framework we describe here provides one example of how earthquake early warning systems can be evaluated.

  2. The Effects of Primary Light Sources on Worker Performance and Alertness

    NASA Technical Reports Server (NTRS)

    Wong, Lily; Caddick, Zachary; Kuriyagawa, Yukiyo; Flynn-Evans, Erin

    2017-01-01

    Traditional office buildings use a variety of primary light sources (e.g., LED/fluorescent lights). As interest in LEED certified office buildings increase and research has shown that enhanced lighting design improves human performance and alertness (Viola et al., 2008; Juslén & Tenner, 2005; Edwards & Torcellini, 2002), more office buildings are incorporating a daylighting design. We investigated the differences between employee performance and alertness in two different building types (daylight vs. artificial light). We hypothesized that employee performance and sleep duration would be improved in a building designed to increase exposure to natural daylight compared to traditional office settings.

  3. Voice Enabled Framework to Support Post-Surgical Discharge Monitoring

    PubMed Central

    Blansit, Kevin; Marmor, Rebecca; Zhao, Beiqun; Tien, Dan

    2017-01-01

    Unplanned surgical readmissions pose a challenging problem for the American healthcare system. We propose to combine consumer electronic voice recognition technology with the FHIR standard to create a post-surgical discharge monitoring app to identify and alert physicians to a patient’s deteriorating status. PMID:29854267

  4. Applying mathematical models to predict resident physician performance and alertness on traditional and novel work schedules.

    PubMed

    Klerman, Elizabeth B; Beckett, Scott A; Landrigan, Christopher P

    2016-09-13

    In 2011 the U.S. Accreditation Council for Graduate Medical Education began limiting first year resident physicians (interns) to shifts of ≤16 consecutive hours. Controversy persists regarding the effectiveness of this policy for reducing errors and accidents while promoting education and patient care. Using a mathematical model of the effects of circadian rhythms and length of time awake on objective performance and subjective alertness, we quantitatively compared predictions for traditional intern schedules to those that limit work to ≤ 16 consecutive hours. We simulated two traditional schedules and three novel schedules using the mathematical model. The traditional schedules had extended duration work shifts (≥24 h) with overnight work shifts every second shift (including every third night, Q3) or every third shift (including every fourth night, Q4) night; the novel schedules had two different cross-cover (XC) night team schedules (XC-V1 and XC-V2) and a Rapid Cycle Rotation (RCR) schedule. Predicted objective performance and subjective alertness for each work shift were computed for each individual's schedule within a team and then combined for the team as a whole. Our primary outcome was the amount of time within a work shift during which a team's model-predicted objective performance and subjective alertness were lower than that expected after 16 or 24 h of continuous wake in an otherwise rested individual. The model predicted fewer hours with poor performance and alertness, especially during night-time work hours, for all three novel schedules than for either the traditional Q3 or Q4 schedules. Three proposed schedules that eliminate extended shifts may improve performance and alertness compared with traditional Q3 or Q4 schedules. Predicted times of worse performance and alertness were at night, which is also a time when supervision of trainees is lower. Mathematical modeling provides a quantitative comparison approach with potential to aid residency programs in schedule analysis and redesign.

  5. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS

    PubMed Central

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930

  6. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS.

    PubMed

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.

  7. Hypoglycemic Accuracy and Improved Low Glucose Alerts of the Latest Dexcom G4 Platinum Continuous Glucose Monitoring System.

    PubMed

    Peyser, Thomas A; Nakamura, Katherine; Price, David; Bohnett, Lucas C; Hirsch, Irl B; Balo, Andrew

    2015-08-01

    Accuracy of continuous glucose monitoring (CGM) devices in hypoglycemia has been a widely reported shortcoming of this technology. We report the accuracy in hypoglycemia of a new version of the Dexcom (San Diego, CA) G4 Platinum CGM system (software 505) and present results regarding the optimum setting of CGM hypoglycemic alerts. CGM values were compared with YSI analyzer (YSI Life Sciences, Yellow Springs, OH) measurements every 15 min. We reviewed the accuracy of the CGM system in the hypoglycemic range using standard metrics. We analyzed the time required for the CGM system to detect biochemical hypoglycemia (70 mg/dL) compared with the YSI with alert settings at 70 mg/dL and 80 mg/dL. We also analyzed the time between the YSI value crossing 55 mg/dL, defined as the threshold for cognitive impairment due to hypoglycemia, and when the CGM system alerted for hypoglycemia. The mean absolute difference for a glucose level of less than 70 mg/dL was 6 mg/dL. Ninety-six percent of CGM values were within 20 mg/dL of the YSI values between 40 and 80 mg/dL. When the CGM hypoglycemic alert was set at 80 mg/dL, the device provided an alert for biochemical hypoglycemia within 10 min in 95% of instances and at least a 10-min advance warning before the cognitive impairment threshold in 91% of instances in the study. Use of an 80 mg/dL threshold setting for hypoglycemic alerts on the G4 Platinum (software 505) may provide patients with timely warning of hypoglycemia before the onset of cognitive impairment, enabling them to treat themselves for hypoglycemia with fast-acting carbohydrates and prevent neuroglycopenia associated with very low glucose levels.

  8. Analysis of clinical decision support system malfunctions: a case series and survey

    PubMed Central

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-01-01

    Objective To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. Materials and Methods We identified and investigated several CDSS malfunctions at Brigham and Women’s Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. Results We identified four CDSS malfunctions at Brigham and Women’s Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. Discussion CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. Conclusion CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. PMID:27026616

  9. Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention

    NASA Technical Reports Server (NTRS)

    Winder, Lee F.; Kuchar, James K.

    2000-01-01

    The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.

  10. The Schoolhouse Is Raining

    ERIC Educational Resources Information Center

    Yee, Roger

    1974-01-01

    Built into 26 new Chicago school designs are two features: physical plants offering educators latitude to remove nearly all internal partitions for open plan teaching or to return to a traditional "eggorate" format if need be; and a new fire control technology placing a building on electronic alert for immediate reaction to dangerous symptoms with…

  11. The Electronic Portfolio: Ethical Considerations

    ERIC Educational Resources Information Center

    McFadden, Joan R.; Saiki, Diana

    2005-01-01

    Computer technology has become important in Family and Consumer Science (FCS) because it offers improved communication with capabilities such as the Internet that allows for a "more productive workplace" (Jones, 2003, p. 38). Kittross and Gordon (2003) alerted users that as computer technology evolves, there is a need for colleges and universities…

  12. Electronic Current Awareness in the Corporate Environment.

    ERIC Educational Resources Information Center

    Sale, Elizabeth

    Technological developments such as groupware and World Wide Web technology have opened up new opportunities for the delivery of information directly to the end-user's desktop. These advances have meant that suppliers are now producing a new breed of current awareness services (CAS), termed alerting services, which automatically filter newswires…

  13. Looking Ahead: The Consequences of a Society with Less Cash/Less Checks

    ERIC Educational Resources Information Center

    MOSAIC, 1976

    1976-01-01

    This technological assessment, conducted by the Arthur D. Little organization, studied the technology of electronic funds transfer. Technology assessment analyzes the economic, social, environmental, and institutional consequences of the introduction or expansion of a technology into society and alerts decision makers to the possible future…

  14. The Final Barrier: Security Consideration in Restricted Access Reading Rooms.

    ERIC Educational Resources Information Center

    Strassberg, Richard

    1997-01-01

    Examines an effective response to library or archive theft and vandalism of valuable materials: the restricted access reading room. Discusses the need for an alert staff, user identification, restriction of carry-in items, electronic surveillance, record keeping, limits to quantities of collection materials, exiting procedure, photocopying, theft…

  15. Automation bias in electronic prescribing.

    PubMed

    Lyell, David; Magrabi, Farah; Raban, Magdalena Z; Pont, L G; Baysari, Melissa T; Day, Richard O; Coiera, Enrico

    2017-03-16

    Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB. One hundred and twenty students in the final two years of a medical degree prescribed medicines for nine clinical scenarios using a simulated e-prescribing system. Quality of CDS (correct, incorrect and no CDS) and task complexity (low, low + interruption and high) were varied between conditions. Omission errors (failure to detect prescribing errors) and commission errors (acceptance of false positive alerts) were measured. Compared to scenarios with no CDS, correct CDS reduced omission errors by 38.3% (p < .0001, n = 120), 46.6% (p < .0001, n = 70), and 39.2% (p < .0001, n = 120) for low, low + interrupt and high complexity scenarios respectively. Incorrect CDS increased omission errors by 33.3% (p < .0001, n = 120), 24.5% (p < .009, n = 82), and 26.7% (p < .0001, n = 120). Participants made commission errors, 65.8% (p < .0001, n = 120), 53.5% (p < .0001, n = 82), and 51.7% (p < .0001, n = 120). Task complexity and interruptions had no impact on AB. This study found evidence of AB omission and commission errors in e-prescribing. Verification of CDS alerts is key to avoiding AB errors. However, interventions focused on this have had limited success to date. Clinicians should remain vigilant to the risks of CDS failures and verify CDS.

  16. Near-real time forecasts of MeV protons based on sub-relativistic electrons: communicating the outputs to the end users

    NASA Astrophysics Data System (ADS)

    Sarlanis, Christos; Heber, Bernd; Labrenz, Johannes; Kühl, Patrick; Marquardt, Johannes; Dimitroulakos, John; Papaioannou, Athanasios; Posner, Arik

    2017-04-01

    Solar Energetic Particle (SEP) events are one of the most important elements of space weather. Given that the complexity of the underlying physical processes of the acceleration and propagation of SEP events is still a very active research area, the prognosis of SEP event occurrence and their corresponding characteristics remains challenging. In order to provide up to an hour warning time before these particles arrive at Earth, relativistic electron and below 50 MeV proton data from the Electron Proton Helium Instrument (EPHIN) on SOHO were used to implement the 'Relativistic Electron Alert System for Exploration (REleASE)'. The REleASE forecasting scheme was recently rewritten in the open access programming language PYTHON and will be made publicly available. As a next step, along with relativistic electrons (v > 0.9 c) provided by SOHO, near-relativistic (v <0.8 c) electron measurements from other instruments like the Electron Proton Alpha Monitor (EPAM) aboard the Advanced Composition Explorer (ACE) have been utilized. In this work, we demonstrate the real-time outputs derived by the end user from the REleASE using both SOHO/EPHIN and ACE/EPAM. We further, show a user friendly illustration of the outputs that make use of a "traffic light" to monitor the different warning stages: quiet, warning, alert offering a simple guidance to the end users. Finally, the capabilities offered by this new system, accessing both the pictorial and textural outputs REleASE are being presented. This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 637324.

  17. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system.

    PubMed

    Bode, Bruce; Gross, Kenneth; Rikalo, Nancy; Schwartz, Sherwyn; Wahl, Timothy; Page, Casey; Gross, Todd; Mastrototaro, John

    2004-04-01

    The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.

  18. Developing Software to “Track and Catch” Missed Follow-up of Abnormal Test Results in a Complex Sociotechnical Environment

    PubMed Central

    Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.

    2013-01-01

    Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789

  19. Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment.

    PubMed

    Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H

    2013-01-01

    Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.

  20. Effects of conflict alerting system reliability and task difficulty on pilots' conflict detection with cockpit display of traffic information.

    PubMed

    Xu, Xidong; Wickens, Christopher D; Rantanen, Esa M

    2007-01-15

    A total of 24 pilots viewed dynamic encounters between their own aircraft and an intruder aircraft on a 2-D cockpit display of traffic information (CDTI) and estimated the point and time of closest approach. A three-level alerting system provided a correct categorical estimate of the projected miss distance on 83% of the trials. The remaining 17% of alerts were equally divided between misses and false alarms, of large and small magnitude. Roughly half the pilots depended on automation to improve estimation of miss distance relative to the baseline pilots, who viewed identical trials without the aid of automated alerts. Moreover, they did so more on the more difficult traffic trials resulting in improved performance on the 83% correct automation trials without causing harm on the 17% automation-error trials, compared to the baseline group. The automated alerts appeared to lead pilots to inspect the raw data more closely. While assisting the accurate prediction of miss distance, the automation led to an underestimate of the time remaining until the point of closest approach. The results point to the benefits of even imperfect automation in the strategic alerts characteristic of the CDTI, at least as long as this reliability remains high (above 80%).

  1. Infant Responsiveness, Alertness, Hemoglobin and Growth in Rural Sidama, Ethiopia

    PubMed Central

    Aubuchon-Endsley, Nicki L.; Grant, Stephanie L.; Thomas, David G.; Kennedy, Tay S.; Berhanu, Getenesh; Stoecker, Barbara J.; Hubbs-Tait, Laura; Hambidge, K. Michael

    2011-01-01

    Several recent studies have supported relations between infant behavior (alertness and responsiveness) and nutrition (e.g. Dempsey 2008, Wachs et al 2005) in addition to investigating infant behavior within the context of changes in iron status over time (e.g. Black et al. 2004, Murray-Kolb & Beard 2009). Existing research is typically limited to investigation of the effects of a single vitamin or mineral and no studies have been found that examined the influence that early alertness and responsiveness have on growth in early infancy, despite the fact that relations between behavior and nutritional status may be bidirectional (Hulthén 2003). The current study used a sample of Ethiopian infants and investigated anthropometrics, hemoglobin, the frequency of alertness, and the frequency of responsiveness at 6 and 9 months of age. Six-month weight-for-age predicted 9-month frequency of alertness, while 6-month hemoglobin predicted 9-month frequency of responsiveness. Compared to responsive infants, non-responsive infants at 6 months remained more non-responsive at 9 months, though weight-for-age for both groups converged at 9 months. Results support relations between nutrition and behavior (alertness and responsiveness) and provide evidence of a potentially useful tool (the Laboratory Temperament Assessment Battery [Lab-TAB]) that was adapted to evaluate these relations in Ethiopia. PMID:22233352

  2. Geodetic Finite-Fault-based Earthquake Early Warning Performance for Great Earthquakes Worldwide

    NASA Astrophysics Data System (ADS)

    Ruhl, C. J.; Melgar, D.; Grapenthin, R.; Allen, R. M.

    2017-12-01

    GNSS-based earthquake early warning (EEW) algorithms estimate fault-finiteness and unsaturated moment magnitude for the largest, most damaging earthquakes. Because large events are infrequent, algorithms are not regularly exercised and insufficiently tested on few available datasets. The Geodetic Alarm System (G-larmS) is a GNSS-based finite-fault algorithm developed as part of the ShakeAlert EEW system in the western US. Performance evaluations using synthetic earthquakes offshore Cascadia showed that G-larmS satisfactorily recovers magnitude and fault length, providing useful alerts 30-40 s after origin time and timely warnings of ground motion for onshore urban areas. An end-to-end test of the ShakeAlert system demonstrated the need for GNSS data to accurately estimate ground motions in real-time. We replay real data from several subduction-zone earthquakes worldwide to demonstrate the value of GNSS-based EEW for the largest, most damaging events. We compare predicted ground acceleration (PGA) from first-alert-solutions with those recorded in major urban areas. In addition, where applicable, we compare observed tsunami heights to those predicted from the G-larmS solutions. We show that finite-fault inversion based on GNSS-data is essential to achieving the goals of EEW.

  3. iFall: an Android application for fall monitoring and response.

    PubMed

    Sposaro, Frank; Tyson, Gary

    2009-01-01

    Injuries due to falls are among the leading causes of hospitalization in elderly persons, often resulting in a rapid decline in quality of life or death. Rapid response can improve the patients outcome, but this is often lacking when the injured person lives alone and the nature of the injury complicates calling for help. This paper presents an alert system for fall detection using common commercially available electronic devices to both detect the fall and alert authorities. We use an Android-based smart phone with an integrated tri-axial accelerometer. Data from the accelerometer is evaluated with several threshold based algorithms and position data to determine a fall. The threshold is adaptive based on user provided parameters such as: height, weight, and level of activity. The algorithm adapts to unique movements that a phone experiences as opposed to similar systems which require users to mount accelerometers to their chest or trunk. If a fall is suspected a notification is raised requiring the user's response. If the user does not respond, the system alerts pre-specified social contacts with an informational message via SMS. If a contact responds the system commits an audible notification, automatically connects, and enables the speakerphone. If a social contact confirms a fall, an appropriate emergency service is alerted. Our system provides a realizable, cost effective solution to fall detection using a simple graphical interface while not overwhelming the user with uncomfortable sensors.

  4. The effects of alcohol mixed with energy drink (AMED) on subjective intoxication and alertness: results from a double-blind placebo-controlled clinical trial.

    PubMed

    van de Loo, Aurora J A E; van Andel, Nienke; van Gelder, Charlotte A G H; Janssen, Boris S G; Titulaer, Joep; Jansen, Jimmy; Verster, Joris C

    2016-05-01

    The purpose of this double blind placebo controlled study was to examine if specific effects on subjective intoxication and alertness-sleepiness ratings could be demonstrated after consuming alcohol mixed with energy drink (AMED) when compared to consuming alcohol only (AO). 56 healthy volunteers rated their subjective intoxication on a scale ranging from 0 (sober) to 10 (highly intoxicated) at baseline, breath alcohol concentration (BAC) of 0%, and at BAC 0.08%, 0.05%, and 0.02%. Alertness-sleepiness was assessed with the Karolinska sleepiness scale. Scores of the AMED and AO condition, at each BAC level, were compared. Subjective intoxication for AMED and AO did not differ significantly from each other at any BAC level, except for BAC 0.02%. A significant increase in sleepiness scores was found in the AO condition, whereas scores remained stable in the AMED condition. Sleepiness scores at BAC0.08% and 0.05% were significantly lower after AMED when compared to AO. However, the observed differences between AMED and AO were small and have no clinical relevance. Mixing alcohol with energy drink had no overall masking effect on subjective intoxication caused by alcohol, nor had a relevant effect on subjective alertness-sleepiness ratings. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Proactive authenticated notifications for health practitioners: two way human computer interaction through phone.

    PubMed

    Majeed, Raphael W; Stöhr, Mark R; Röhrig, Rainer

    2012-01-01

    Notifications and alerts play an important role in clinical daily routine. Rising prevalence of clinical decision support systems and electronic health records also result in increasing demands on notification systems. Failure adequately to communicate a critical value is a potential cause of adverse events. Critical laboratory values and changing vital data depend on timely notifications of medical staff. Vital monitors and medical devices rely on acoustic signals for alerting which are prone to "alert fatigue" and require medical staff to be present within audible range. Personal computers are unsuitable to display time critical notification messages, since the targeted medical staff are not always operating or watching the computer. On the other hand, mobile phones and smart devices enjoy increasing popularity. Previous notification systems sending text messages to mobile phones depend on asynchronous confirmations. By utilizing an automated telephony server, we provide a method to deliver notifications quickly and independently of the recipients' whereabouts while allowing immediate feedback and confirmations. Evaluation results suggest the feasibility of the proposed notification system for real-time notifications.

  6. Extended workdays: Effects of 8-hour and 12-hour rotating shift schedules on test performance, subjective alertness, sleep patterns, and psychological variables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosa, R.R.; Colligan, M.J.; Lewis, P.

    1986-06-01

    A newly instituted 3 to 4 day/12-hr rotating shift schedule was compared to the previous 5 to 7 day/8-hr schedule using standard laboratory-type measures of performance and alertness, and a questionnaire on sleep patterns and other personal habits. After seven months adaptation to the new schedule, a preliminary analysis indicates that there were some decrements in alertness, reductions in sleep, and disruptions of other personal activities during 12-hr workdays. Gastro-intestinal state improved during night shift, however, and increases in self-reported stress were reduced by the shortened workweek. These results are discussed in terms of trade-offs between longer workdays and shortermore » workweeks. It is emphasized that at this time no determination can be made of the extent of risk associated with these changes in alertness.« less

  7. Brewer spectrophotometer measurements in the Canadian Arctic

    NASA Technical Reports Server (NTRS)

    Kerr, J. B.; Evans, W. F. J.

    1988-01-01

    In the winters of 1987 and 1988 measurements were conducted with the Brewer Spectrophotometer at Alert (82.5 N) and Resolute (74.5 N). The measurements were conducted as part of our Canadian Program to search for an Arctic Ozone Hole (CANOZE). Ozone measurements were conducted in the months of December, January and February using the moon as a light source. The total ozone measurements will be compared with ozonesonde profiles, from ECC sondes, flown once per week from Alert and Resolute. A modified Brewer Spectrophotometer was used in a special study to search for chlorine dioxide at Alert in March 1987. Ground based observations at Saskatoon in February and at Alert in March 1987 failed to detect any measureable chlorine dioxide. Interference from another absorbing gas, which we speculate may be nitrous acid, prevented the measurements at the low levels of chlorine dioxide detected in the Southern Hemisphere by Solomon et al.

  8. Generator replacement is associated with an increased rate of ICD lead alerts.

    PubMed

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Automated critical test result notification system: architecture, design, and assessment of provider satisfaction.

    PubMed

    Lacson, Ronilda; O'Connor, Stacy D; Andriole, Katherine P; Prevedello, Luciano M; Khorasani, Ramin

    2014-11-01

    Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers' satisfaction with ANCR; and to compare radiologists' and ordering providers' attitudes toward ANCR. The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety.

  10. Automated Critical Test Result Notification System: Architecture, Design, and Assessment of Provider Satisfaction

    PubMed Central

    Lacson, Ronilda; O'Connor, Stacy D.; Andriole, Katherine P.; Prevedello, Luciano M.; Khorasani, Ramin

    2015-01-01

    OBJECTIVE Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers’ satisfaction with ANCR; and to compare radiologists’ and ordering providers’ attitudes toward ANCR. MATERIALS AND METHODS The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. RESULTS The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. CONCLUSION Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety. PMID:25341163

  11. Alerts of forest disturbance from MODIS imagery

    NASA Astrophysics Data System (ADS)

    Hammer, Dan; Kraft, Robin; Wheeler, David

    2014-12-01

    This paper reports the methodology and computational strategy for a forest cover disturbance alerting system. Analytical techniques from time series econometrics are applied to imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor to detect temporal instability in vegetation indices. The characteristics from each MODIS pixel's spectral history are extracted and compared against historical data on forest cover loss to develop a geographically localized classification rule that can be applied across the humid tropical biome. The final output is a probability of forest disturbance for each 500 m pixel that is updated every 16 days. The primary objective is to provide high-confidence alerts of forest disturbance, while minimizing false positives. We find that the alerts serve this purpose exceedingly well in Pará, Brazil, with high probability alerts garnering a user accuracy of 98 percent over the training period and 93 percent after the training period (2000-2005) when compared against the PRODES deforestation data set, which is used to assess spatial accuracy. Implemented in Clojure and Java on the Hadoop distributed data processing platform, the algorithm is a fast, automated, and open source system for detecting forest disturbance. It is intended to be used in conjunction with higher-resolution imagery and data products that cannot be updated as quickly as MODIS-based data products. By highlighting hotspots of change, the algorithm and associated output can focus high-resolution data acquisition and aid in efforts to enforce local forest conservation efforts.

  12. Exposure to blue light during lunch break: effects on autonomic arousal and behavioral alertness.

    PubMed

    Yuda, Emi; Ogasawara, Hiroki; Yoshida, Yutaka; Hayano, Junichiro

    2017-07-11

    Exposures to melanopsin-stimulating (melanopic) component-rich blue light enhance arousal level. We examined their effects in office workers. Eight healthy university office workers were exposed to blue and orange lights for 30 min during lunch break on different days. We compared the effects of light color on autonomic arousal level assessed by heart rate variability (HRV) and behavioral alertness by psychomotor vigilance tests (PVT). Heart rate was higher and high-frequency (HF, 0.150.45 Hz) power of HRV was lower during exposure to the blue light than to orange light. No significant difference with light color was observed, however, in any HRV indices during PVT or in PVT performance after light exposure. Exposure to blue light during lunch break, compared with that to orange light, enhances autonomic arousal during exposure, but has no sustained effect on autonomic arousal or behavioral alertness after exposure.

  13. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    NASA Astrophysics Data System (ADS)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to monitoring cognitive or mental states of human operators in attention-critical settings or in passive brain-computer interfaces.

  14. Space Environment Forecasting with Neutron Monitors: Establishing a novel service for the ESA SSA Program

    NASA Astrophysics Data System (ADS)

    Papaioannou, Athanasios; Mavromichalaki, Helen; Souvatzoglou, George; Paschalis, Pavlos; Sarlanis, Christos; Dimitroulakos, John; Gerontidou, Maria

    2013-04-01

    High-energy particles released at the Sun during a solar flare or a very energetic coronal mass ejection, result to a significant intensity increase at neutron monitor measurements known as Ground Level Enhancements (GLEs). Due to their space weather impact (i.e. risks and failures at communication and navigation systems, spacecraft electronics and operations, space power systems, manned space missions, and commercial aircraft operations) it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Currently, the Cosmic Ray group of the National and Kapodistrian University of Athens is working towards the establishment of a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program. To this end, a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert will be provided. Both services are now under testing and validation and they will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software, to minimize the probability of a false alarm and to enhance the usability of the corresponding results. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the Neutron Monitor Service for ESA SSA Program and the impact of the novel GLE Alert Service that will be made available to future users via ESA SSA web portal will be presented and further discussed.

  15. Analysis of clinical decision support system malfunctions: a case series and survey.

    PubMed

    Wright, Adam; Hickman, Thu-Trang T; McEvoy, Dustin; Aaron, Skye; Ai, Angela; Andersen, Jan Marie; Hussain, Salman; Ramoni, Rachel; Fiskio, Julie; Sittig, Dean F; Bates, David W

    2016-11-01

    To illustrate ways in which clinical decision support systems (CDSSs) malfunction and identify patterns of such malfunctions. We identified and investigated several CDSS malfunctions at Brigham and Women's Hospital and present them as a case series. We also conducted a preliminary survey of Chief Medical Information Officers to assess the frequency of such malfunctions. We identified four CDSS malfunctions at Brigham and Women's Hospital: (1) an alert for monitoring thyroid function in patients receiving amiodarone stopped working when an internal identifier for amiodarone was changed in another system; (2) an alert for lead screening for children stopped working when the rule was inadvertently edited; (3) a software upgrade of the electronic health record software caused numerous spurious alerts to fire; and (4) a malfunction in an external drug classification system caused an alert to inappropriately suggest antiplatelet drugs, such as aspirin, for patients already taking one. We found that 93% of the Chief Medical Information Officers who responded to our survey had experienced at least one CDSS malfunction, and two-thirds experienced malfunctions at least annually. CDSS malfunctions are widespread and often persist for long periods. The failure of alerts to fire is particularly difficult to detect. A range of causes, including changes in codes and fields, software upgrades, inadvertent disabling or editing of rules, and malfunctions of external systems commonly contribute to CDSS malfunctions, and current approaches for preventing and detecting such malfunctions are inadequate. CDSS malfunctions occur commonly and often go undetected. Better methods are needed to prevent and detect these malfunctions. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  16. A clinical decision support system algorithm for intravenous to oral antibiotic switch therapy: validity, clinical relevance and usefulness in a three-step evaluation study.

    PubMed

    Akhloufi, H; Hulscher, M; van der Hoeven, C P; Prins, J M; van der Sijs, H; Melles, D C; Verbon, A

    2018-04-26

    To evaluate a clinical decision support system (CDSS) based on consensus-based intravenous to oral switch criteria, which identifies intravenous to oral switch candidates. A three-step evaluation study of a stand-alone CDSS with electronic health record interoperability was performed at the Erasmus University Medical Centre in the Netherlands. During the first step, we performed a technical validation. During the second step, we determined the sensitivity, specificity, negative predictive value and positive predictive value in a retrospective cohort of all hospitalized adult patients starting at least one therapeutic antibacterial drug between 1 and 16 May 2013. ICU, paediatric and psychiatric wards were excluded. During the last step the clinical relevance and usefulness was prospectively assessed by reports to infectious disease specialists. An alert was considered clinically relevant if antibiotics could be discontinued or switched to oral therapy at the time of the alert. During the first step, one technical error was found. The second step yielded a positive predictive value of 76.6% and a negative predictive value of 99.1%. The third step showed that alerts were clinically relevant in 53.5% of patients. For 43.4% it had already been decided to discontinue or switch the intravenous antibiotics by the treating physician. In 10.1%, the alert resulted in advice to change antibiotic policy and was considered useful. This prospective cohort study shows that the alerts were clinically relevant in >50% (n = 449) and useful in 10% (n = 85). The CDSS needs to be evaluated in hospitals with varying activity of infectious disease consultancy services as this probably influences usefulness.

  17. Emergency Notification in an Instant

    ERIC Educational Resources Information Center

    Galuszka, Peter

    2008-01-01

    In the past year, adding new security has "become like a religion." The business of electronic notification hadn't really gained much attention until the terrorist attacks that destroyed the World Trade Center and damaged the Pentagon in 2001, killing more than 3,000 people. Critical attention on alerts got a huge boost after the Virginia Tech…

  18. Libraries without Resources: Towards Personal Collections.

    ERIC Educational Resources Information Center

    Savenije, Bas; Grygierczyk, Natalia

    The main function of the library of the future is to provide access to electronic sources stored elsewhere. In order to comply with the users' needs, therefore, flexible license scenarios are necessary. Another future function of the library will be to set up and maintain a personal alerting system and to assist users in organizing their own…

  19. Stop the Pediatric Obesity Epidemic: Is the EMR a Solution to Alert Providers?

    ERIC Educational Resources Information Center

    Williams, Kim

    2016-01-01

    Introduction: Weight management is an unrelenting issue affecting people of all ages. Addressing weight management is among the priority health concerns in the United States. Evidence suggests that some health providers are not recognizing or managing patients' weight management issues. The electronic medical record and automation may help…

  20. Asan medical information system for healthcare quality improvement.

    PubMed

    Ryu, Hyeon Jeong; Kim, Woo Sung; Lee, Jae Ho; Min, Sung Woo; Kim, Sun Ja; Lee, Yong Su; Lee, Young Ha; Nam, Sang Woo; Eo, Gi Seung; Seo, Sook Gyoung; Nam, Mi Hyun

    2010-09-01

    This purpose of this paper is to introduce the status of the Asan Medical Center (AMC) medical information system with respect to healthcare quality improvement. Asan Medical Information System (AMIS) is projected to become a completely electronic and digital information hospital. AMIS has played a role in improving the health care quality based on the following measures: safety, effectiveness, patient-centeredness, timeliness, efficiency, privacy, and security. AMIS CONSISTED OF SEVERAL DISTINCTIVE SYSTEMS: order communication system, electronic medical record, picture archiving communication system, clinical research information system, data warehouse, enterprise resource planning, IT service management system, and disaster recovery system. The most distinctive features of AMIS were the high alert-medication recognition & management system, the integrated and severity stratified alert system, the integrated patient monitoring system, the perioperative diabetic care monitoring and support system, and the clinical indicator management system. AMIS provides IT services for AMC, 7 affiliated hospitals and over 5,000 partners clinics, and was developed to improve healthcare services. The current challenge of AMIS is standard and interoperability. A global health IT strategy is needed to get through the current challenges and to provide new services as needed.

  1. Automated Detection of Sepsis Using Electronic Medical Record Data: A Systematic Review.

    PubMed

    Despins, Laurel A

    Severe sepsis and septic shock are global issues with high mortality rates. Early recognition and intervention are essential to optimize patient outcomes. Automated detection using electronic medical record (EMR) data can assist this process. This review describes automated sepsis detection using EMR data. PubMed retrieved publications between January 1, 2005 and January 31, 2015. Thirteen studies met study criteria: described an automated detection approach with the potential to detect sepsis or sepsis-related deterioration in real or near-real time; focused on emergency department and hospitalized neonatal, pediatric, or adult patients; and provided performance measures or results indicating the impact of automated sepsis detection. Detection algorithms incorporated systemic inflammatory response and organ dysfunction criteria. Systems in nine studies generated study or care team alerts. Care team alerts did not consistently lead to earlier interventions. Earlier interventions did not consistently translate to improved patient outcomes. Performance measures were inconsistent. Automated sepsis detection is potentially a means to enable early sepsis-related therapy but current performance variability highlights the need for further research.

  2. Effect of station-specific alerting and ramp-up tones on firefighters' alarm time heart rates.

    PubMed

    MacNeal, James J; Cone, David C; Wistrom, Christopher L

    2016-11-01

    A number of long-term health effects are suffered by emergency responders, some influenced by psychological stress and fatigue. This study explored if stress and fatigue can be reduced by changing the method by which firefighters are alerted to emergency responses. Over several months, the method by which responders at a fire department were alerted was altered. Firefighter heart rates were measured first with standard alerting as a control (phase 1: all stations alerted simultaneously, with high-volume tones). The department then implemented station-specific (phase 2) and gradual volume ramp-up (phase 3) tone alerting, and heart rate increases were compared. The Fatigue Severity Score was used to examine firefighter fatigue, and the department administered a follow-up survey on personnel preferences. Individual heart rate increases (Δbpm) ranged from 2-48 bpm. Median increases were 7 bpm (IQR 4-11 bpm) during phase 1 (72.2% of alarms Δbpm<10), 7 bpm (IQR 5-12 bpm) during phase 2 (60.7% of alarms Δbpm<10), and 5 bpm (IQR 3-8 bpm) during phase 3 (82.7% of alarms Δbpm<10). The difference in medians was lower for phases 1 and 2 than for phase 3 (p = 0.0069), and more alarms in phase 3 resulted in increases of <10 bpm than in phase 2 (p = 0.0089). The Fatigue Severity Scale showed little variability: median scores 7 in phase 1, 8 in phase 2, and 7 in phase 3. Firefighters reported a strong preference for the "ramp-up" tones, and were roughly evenly divided between preferring alerting all stations simultaneously 24/7 (40% rating this 4 or 5 on a five-point Likert scale), station-specific alerting 24/7 (47.5%), or all stations during the day but station-specific at night (40%). Ramp-up tones were perceived as the best method to reduce stress during the day and overnight. Small but significant decreases in the amount of tachycardic response to station alerting are associated with simple alterations in alerting methods. Station-specific and ramp-up tones improve perceived working conditions for emergency responders.

  3. Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

    NASA Technical Reports Server (NTRS)

    Song, Lixia; Kuchar, James K.

    2003-01-01

    Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air traffic alert and avoidance systems: the existing Traffic Alert and Collision Avoidance System (TCAS) vs. the proposed Airborne Conflict Management system (ACM). Conditions on ACM resolution maneuvers are identified to avoid dynamic dissonance between TCAS and ACM. Also included in this report is an Appendix written by Lee Winder about recent and continuing work on alerting systems design. The application of Markov Decision Process (MDP) theory to complex alerting problems is discussed and illustrated with an abstract example system.

  4. Impact of electronic health record clinical decision support on the management of pediatric obesity.

    PubMed

    Shaikh, Ulfat; Berrong, Jeanette; Nettiksimmons, Jasmine; Byrd, Robert S

    2015-01-01

    Clinicians vary significantly in their adherence to clinical guidelines for overweight/obesity. This study assessed the impact of electronic health record-based clinical decision support in improving the diagnosis and management of pediatric obesity. The study team programmed a point-of-care alert linked to a checklist and standardized documentation templates to appear during health maintenance visits for overweight/obese children in an outpatient teaching clinic and compared outcomes through medical record reviews of 574 (287 control and 287 intervention) visits. The results demonstrated a statistically significant increase in the diagnosis of overweight/obesity, scheduling of follow-up appointments, frequency of ordering recommended laboratory investigations, and assessment and counseling for nutrition and physical activity. Although clinical guideline adherence increased significantly, it was far from universal. It is unknown if modest improvements in adherence to clinical guidelines translate to improvements in children's health. However, this intervention was relatively easy to implement and produced measurable improvements in health care delivery. © 2014 by the American College of Medical Quality.

  5. A long-term follow-up evaluation of electronic health record prescribing safety

    PubMed Central

    Abramson, Erika L; Malhotra, Sameer; Osorio, S Nena; Edwards, Alison; Cheriff, Adam; Cole, Curtis; Kaushal, Rainu

    2013-01-01

    Objective To be eligible for incentives through the Electronic Health Record (EHR) Incentive Program, many providers using older or locally developed EHRs will be transitioning to new, commercial EHRs. We previously evaluated prescribing errors made by providers in the first year following transition from a locally developed EHR with minimal prescribing clinical decision support (CDS) to a commercial EHR with robust CDS. Following system refinements, we conducted this study to assess the rates and types of errors 2 years after transition and determine the evolution of errors. Materials and methods We conducted a mixed methods cross-sectional case study of 16 physicians at an academic-affiliated ambulatory clinic from April to June 2010. We utilized standardized prescription and chart review to identify errors. Fourteen providers also participated in interviews. Results We analyzed 1905 prescriptions. The overall prescribing error rate was 3.8 per 100 prescriptions (95% CI 2.8 to 5.1). Error rates were significantly lower 2 years after transition (p<0.001 compared to pre-implementation, 12 weeks and 1 year after transition). Rates of near misses remained unchanged. Providers positively appreciated most system refinements, particularly reduced alert firing. Discussion Our study suggests that over time and with system refinements, use of a commercial EHR with advanced CDS can lead to low prescribing error rates, although more serious errors may require targeted interventions to eliminate them. Reducing alert firing frequency appears particularly important. Our results provide support for federal efforts promoting meaningful use of EHRs. Conclusions Ongoing error monitoring can allow CDS to be optimally tailored and help achieve maximal safety benefits. Clinical Trials Registration ClinicalTrials.gov, Identifier: NCT00603070. PMID:23578816

  6. Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.

    PubMed

    Lim, Paul Chun Yih; Lee, Audry Shan Yin; Chua, Kelvin Chi Ming; Lim, Eric Tien Siang; Chong, Daniel Thuan Tee; Tan, Boon Yew; Ho, Kah Leng; Teo, Wee Siong; Ching, Chi Keong

    2016-07-01

    Remote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network. Patients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians. A total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported. Remote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life. Copyright: © Singapore Medical Association.

  7. Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study

    PubMed Central

    Lim, Paul Chun Yih; Lee, Audry Shan Yin; Chua, Kelvin Chi Ming; Lim, Eric Tien Siang; Chong, Daniel Thuan Tee; Tan, Boon Yew; Ho, Kah Leng; Teo, Wee Siong; Ching, Chi Keong

    2016-01-01

    INTRODUCTION Remote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink® network. METHODS Patients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians. RESULTS A total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported. CONCLUSION Remote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life. PMID:27439396

  8. Lack of utility of a decision support system to mitigate delays in admission from the operating room to the postanesthesia care unit.

    PubMed

    Ehrenfeld, Jesse M; Dexter, Franklin; Rothman, Brian S; Minton, Betty Sue; Johnson, Diane; Sandberg, Warren S; Epstein, Richard H

    2013-12-01

    When the phase I postanesthesia care unit (PACU) is at capacity, completed cases need to be held in the operating room (OR), causing a "PACU delay." Statistical methods based on historical data can optimize PACU staffing to achieve the least possible labor cost at a given service level. A decision support process to alert PACU charge nurses that the PACU is at or near maximum census might be effective in lessening the incidence of delays and reducing over-utilized OR time, but only if alerts are timely (i.e., neither too late nor too early to act upon) and the PACU slot can be cleared quickly. We evaluated the maximum potential benefit of such a system, using assumptions deliberately biased toward showing utility. We extracted 3 years of electronic PACU data from a tertiary care medical center. At this hospital, PACU admissions were limited by neither inadequate PACU staffing nor insufficient PACU beds. We developed a model decision support system that simulated alerts to the PACU charge nurse. PACU census levels were reconstructed from the data at a 1-minute level of resolution and used to evaluate if subsequent delays would have been prevented by such alerts. The model assumed there was always a patient ready for discharge and an available hospital bed. The time from each alert until the maximum census was exceeded ("alert lead time") was determined. Alerts were judged to have utility if the alert lead time fell between various intervals from 15 or 30 minutes to 60, 75, or 90 minutes after triggering. In addition, utility for reducing over-utilized OR time was assessed using the model by determining if 2 patients arrived from 5 to 15 minutes of each other when the PACU census was at 1 patient less than the maximum census. At most, 23% of alerts arrived 30 to 60 minutes prior to the admission that resulted in the PACU exceeding the specified maximum capacity. When the notification window was extended to 15 to 90 minutes, the maximum utility was <50%. At most, 45% of alerts potentially would have resulted in reassigning the last available PACU slot to 1 OR versus another within 15 minutes of the original assignment. Despite multiple biases that favored effectiveness, the maximum potential benefit of a decision support system to mitigate PACU delays on the day on the surgery was below the 70% minimum threshold for utility of automated decision support messages, previously established via meta-analysis. Neither reduction in PACU delays nor reassigning promised PACU slots based on reducing over-utilized OR time were realized sufficiently to warrant further development of the system. Based on these results, the only evidence-based method of reducing PACU delays is to adjust PACU staffing and staff scheduling using computational algorithms to match the historical workload (e.g., as developed in 2001).

  9. Reducing Symptom Distress in Patients With Advanced Cancer Using an e-Alert System for Caregivers: Pooled Analysis of Two Randomized Clinical Trials

    PubMed Central

    DuBenske, Lori L; Atwood, Amy K; Chih, Ming-Yuan; Johnson, Roberta A; McTavish, Fiona; Quanbeck, Andrew; Brown, Roger L; Cleary, James F; Shah, Dhavan

    2017-01-01

    Background Symptom distress in patients toward the end of life can change rapidly. Family caregivers have the potential to help patients manage those symptoms, as well as their own stress, if they are equipped with the proper resources. Electronic health (eHealth) systems may be able to provide those resources. Very sick patients may not be able to use such systems themselves to report their symptoms but family caregivers could. Objective The aim of this paper was to assess the effects on cancer patient symptom distress of an eHealth system that alerts clinicians to significant changes in the patient’s symptoms, as reported by a family caregiver. Methods A pooled analysis from two randomized clinical trials (NCT00214162 and NCT00365963) compared outcomes at 12 months for two unblinded groups: a control group (Comprehensive Health Enhancement Support System [CHESS]-Only) that gave caregivers access to CHESS, an online support system, and an experimental group (CHESS+CR [Clinician Report]), which also had CHESS but with a CR that automatically alerted clinicians if symptoms exceeded a predetermined threshold of severity. Participants were dyads (n=235) of patients with advanced lung, breast, or prostate cancer and their respective family caregivers from 5 oncology clinics in the United States of America. The proportion of improved patient threshold symptoms was compared between groups using area-under-the-curve analysis and binomial proportion tests. The proportion of threshold symptoms out of all reported symptoms was also examined. Results When severe caregiver-reported symptoms were shared with clinicians, the symptoms were more likely to be subsequently reported as improved than when the symptoms were not shared with clinicians (P<.001). Fewer symptom reports were completed in the group of caregivers whose reports went to clinicians than in the CHESS-Only group (P<.001), perhaps because caregivers, knowing their reports might be sent to a doctor, feared they might be bothering the clinician. Conclusions This study suggests that an eHealth system designed for caregivers that alerts clinicians to worrisome changes in patient health status may lead to reduced patient distress. Trial Registration Clinicaltrials.gov NCT00214162; https://clinicaltrials.gov/ct2/show/NCT00214162 (Archived by WebCite at http://www.webcitation.org/6nmgdGfuD) and Clinicaltrials.gov NCT00365963; https://clinicaltrials.gov/ct2/show/NCT00365963 (Archived by WebCite at http://www.webcitation.org/6nmh0U8VP) PMID:29138131

  10. The Diagnostic Utility of Bact/ALERT and Nested PCR in the Diagnosis of Tuberculous Meningitis.

    PubMed

    Sastry, Apurba Sankar; Bhat K, Sandhya; Kumudavathi

    2013-01-01

    The early laboratory diagnosis of Tuberculous Meningitis (TBM) is crucial, to start the antitubercular chemotherapy and to prevent its complications. However, the conventional methods are either less sensitive or time consuming. Hence, the diagnostic potentials of BacT/ALERT and Polymerase Chain Reaction (PCR) was evaluated in this study. The study group comprised of 62 cases and 33 controls. The cases were divided according to Ahuja's criteria into the confirmed (two cases), highly probable (19 cases), probable (26 cases) and the possible (15 cases) subgroups. Ziehl Neelsen's (ZN) and Auramine Phenol (AP) staining, Lowenstein Jensen (LJ) medium culture, BacT/ALERT and nested Polymerase Chain Reaction (PCR) which targeted IS6110 were carried out on all the patients. The sensitivity of the LJ culture was 3.22%. BacT/ALERT showed a sensitivity and a specificity of 25.80% and 100% and those of nested PCR were found to be 40.32% and 96.97% respectively. The mean detection time of growth of the LJ culture was 31.28 days, whereas that of BacT/ALERT was 20.68 days. The contamination rate in the LJ culture and BacT/ALERT were 7.2% and 5.8% respectively. Nested PCR was found to be more sensitive, followed by BacT/ALERT as compared to the LJ culture and smear microscopy. As both false negative and false positive results have been reported for nested PCR, so it should not be used alone as a criterion for initiating or terminating the therapy, but it should be supported by clinical, radiological, cytological and other microbiological findings.

  11. Physician response to a medication alert system in inpatients with levodopa-treated diseases

    PubMed Central

    Morris, Marie; Willis, Allison W.; Searles Nielsen, Susan; McCann, Franklin; Birke, Angela

    2015-01-01

    Objective: To evaluate the appropriateness of dopamine receptor antagonist prescriptions in hospitalized patients with dopamine-requiring diseases after implementation of an automated prescription alert system. Methods: We examined dopamine receptor antagonist prescriptions in hospitalized patients with dopamine-requiring diseases and physician response to an automated drug contraindication alert system at Barnes-Jewish Hospital from 2009 to 2013. A detailed review of patient medical records was performed for all alert events generated when a physician prescribed a dopamine receptor antagonist concurrently with a dopamine receptor agonist in hospitalized patients. Two movement disorders neurologists determined the appropriateness of each prescription, based on patient medical history, through consensus. Physician response to alert was compared by indication for the prescription and physician specialty. Results: Of 237 orders, 197 (83.1%) prescriptions for dopamine receptor antagonists were considered inappropriate. The prevalence of inappropriate dopamine receptor antagonist prescriptions per levodopa prescriptions was 16.10% (95% confidence interval 9.47, 22.73) in psychiatry, 7.51% (6.16, 8.86) in general medicine, 6.14% (4.49, 7.79) in the surgical specialties, and 0.85% (0.46, 1.25) in the neurologic/neurosurgical specialties. Of the inappropriate prescriptions, 146 (74.1%) were continued despite the alert. The strongest predictor of discontinuation of dopamine receptor antagonist medications was use of the medication to treat nausea or emesis (p < 0.001). Conclusions: Despite successfully identifying instances when dopamine antagonists were prescribed to patients with dopamine-requiring diseases, the alert system modestly affected physician prescribing behavior, highlighting the need for improved education of health care providers. PMID:26092916

  12. Handler beliefs affect scent detection dog outcomes.

    PubMed

    Lit, Lisa; Schweitzer, Julie B; Oberbauer, Anita M

    2011-05-01

    Our aim was to evaluate how human beliefs affect working dog outcomes in an applied environment. We asked whether beliefs of scent detection dog handlers affect team performance and evaluated relative importance of human versus dog influences on handlers' beliefs. Eighteen drug and/or explosive detection dog/handler teams each completed two sets of four brief search scenarios (conditions). Handlers were falsely told that two conditions contained a paper marking scent location (human influence). Two conditions contained decoy scents (food/toy) to encourage dog interest in a false location (dog influence). Conditions were (1) control; (2) paper marker; (3) decoy scent; and (4) paper marker at decoy scent. No conditions contained drug or explosive scent; any alerting response was incorrect. A repeated measures analysis of variance was used with search condition as the independent variable and number of alerts as the dependent variable. Additional nonparametric tests compared human and dog influence. There were 225 incorrect responses, with no differences in mean responses across conditions. Response patterns differed by condition. There were more correct (no alert responses) searches in conditions without markers. Within marked conditions, handlers reported that dogs alerted more at marked locations than other locations. Handlers' beliefs that scent was present potentiated handler identification of detection dog alerts. Human more than dog influences affected alert locations. This confirms that handler beliefs affect outcomes of scent detection dog deployments.

  13. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    PubMed

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Using clinical simulation centers to test design interventions: a pilot study of lighting and color modifications.

    PubMed

    Gray, Whitney Austin; Kesten, Karen S; Hurst, Stephen; Day, Tama Duffy; Anderko, Laura

    2012-01-01

    The aim of this pilot study was to test design interventions such as lighting, color, and spatial color patterning on nurses' stress, alertness, and satisfaction, and to provide an example of how clinical simulation centers can be used to conduct research. The application of evidence-based design research in healthcare settings requires a transdisciplinary approach. Integrating approaches from multiple fields in real-life settings often proves time consuming and experimentally difficult. However, forums for collaboration such as clinical simulation centers may offer a solution. In these settings, identical operating and patient rooms are used to deliver simulated patient care scenarios using automated mannequins. Two identical rooms were modified in the clinical simulation center. Nurses spent 30 minutes in each room performing simulated cardiac resuscitation. Subjective measures of nurses' stress, alertness, and satisfaction were collected and compared between settings and across time using matched-pair t-test analysis. Nurses reported feeling less stressed after exposure to the experimental room than nurses who were exposed to the control room (2.22, p = .03). Scores post-session indicated a significant reduction in stress and an increase in alertness after exposure to the experimental room as compared to the control room, with significance levels below .10. (Change in stress scores: 3.44, p = .069); (change in alertness scores: 3.6, p = .071). This study reinforces the use of validated survey tools to measure stress, alertness, and satisfaction. Results support human-centered design approaches by evaluating the effect on nurses in an experimental setting.

  15. Fatigue Countermeasures in Aviation

    DTIC Science & Technology

    2009-01-01

    on the Use of Hypnotics b. Improving Sleep and Alertness i. Healthy Sleep Practices ii. Napping iii. Circadian Adjustment iv. Exercise v. Nutrition ...observed that a 90% CHO meal with a high glycemic index (GI) shortened sleep latency by about 50% compared to a low glycemic index meal, and about 40% when...postduty day sleep is disturbed mini- mally by caffeine use . With tIle exception of caffeine and various nutritional supplements, no alertness

  16. Deliberate real-time mood regulation in adulthood: the importance of age, fixation and attentional functioning.

    PubMed

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M

    2011-09-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N=39) and older (N=44) adults' use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimise the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual's own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention.

  17. Deliberate Real-time Mood Regulation in Adulthood: The Importance of Age, Fixation and Attentional Functioning

    PubMed Central

    Noh, Soo Rim; Lohani, Monika; Isaacowitz, Derek M.

    2011-01-01

    While previous research has linked executive attention to emotion regulation, the current study investigated the role of attentional alerting (i.e., efficient use of external warning cues) on younger (N = 39) and older (N = 44) adults’ use of gaze to regulate their mood in real time. Participants viewed highly arousing unpleasant images while reporting their mood and were instructed to deliberately manage how they felt and to minimize the effect of those stimuli on their mood. Fixations toward the most negative areas of the images were recorded with eye tracking. We examined whether looking less at the most negative regions, compared to each individual’s own tendency, was a beneficial mood regulatory strategy and how it interacted with age and alerting ability. High alerting older adults, who rely more on external cues to guide their attention, experienced a smaller decline in mood over time by activating a less-negative-looking approach (compared to their own average tendency), effectively looking away from the most negative areas of the images. More negative gaze patterns predicted better mood for younger adults, though this effect decreased over time. Alerting did not moderate gaze-mood links in younger adults. Successful mood regulation may thus depend on particular combinations of age, fixation, and attention. PMID:21432641

  18. Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems.

    PubMed

    Somily, Ali Mohammed; Habib, Hanan Ahmed; Torchyan, Armen Albert; Sayyed, Samina B; Absar, Muhammed; Al-Aqeel, Rima; Binkhamis, A Khalifa

    2018-01-01

    Bloodstream infections are associated with high rates of morbidity and mortality. Rapid detection of bloodstream infections is important in achieving better patient outcomes. Compare the time-to-detection (TTD) of the new BacT/Alert Virtuo and the BACTEC FX automated blood culture systems. Prospective simulated comparison of two instruments using seeded samples. Medical microbiology laboratory. Blood culture bottles were seeded in triplicate with each of the standard ATCC strains of aerobes, anaerobes and yeast. TTD was calculated as the length of time from the beginning of culture incubation to the detection of bacterial growth. TTD for the various tested organisms on the two microbial detection systems. The 99 bottles of seeded blood cultures incubated in each of the blood culture systems included 21 anaerobic, 39 aerobic and 39 pediatric bottles. The BacT/Alert Virtuo system exhibited significantly shorter TTD for 72.7 % of the tested organisms compared to BACTEC FX system with a median difference in mean TTD of 2.1 hours (interquartile range: 1.5-3.5 hours). The BACTEC FX system was faster in 15.2% (5/33) of microorganisms, with a median difference in mean TTD of 25.9 hours (IQR: 9.1-29.2 hours). TTD was significantly shorter for most of the microorganisms tested on the new BacT/Alert Virtuo system compared to the BACTEC FX system. Use of simulated cultures to assess TTD may not precisely represent clinical blood cultures. None.

  19. E-Book Purchasing Best Practices for Academic Libraries

    ERIC Educational Resources Information Center

    Simon, Jason C.

    2014-01-01

    This article alerts academic libraries to some of the methods for purchasing electronic books (e-books) and notes that, while they are similar to the models used for journal-evaluation purposes, there are a number of factors important to consider that are different for e-books. Simon notes that, while theoretically there should be some advantages…

  20. Personalised electronic messages to improve sun protection in young adults.

    PubMed

    Mair, Sarah; Soyer, H Peter; Youl, Philippa; Hurst, Cameron; Marshall, Alison; Janda, Monika

    2012-07-01

    We studied the acceptability and feasibility of delivering sun protection messages via electronic media such as short message services (SMS) to people aged 18-40 years. An online survey was conducted using a pre-established panel of volunteers. We compared the characteristics of those who indicated that they would like to be alerted to the UV index, with those who would not, using bivariate logistic regression. Characteristics found to be associated with a desire to receive such advice were entered into a multivariate logistic regression analysis. The median age of the 141 participants was 34 years. Overall, 80% of participants agreed that they would like to receive some form of sun protection advice. Of these, 20% preferred to receive it via SMS and 42% via email. Willingness to receive electronic messages about the UV index was associated with being unsure about whether a suntanned person would look healthy and greater use of sun protection in the past. Careful attention to message framing and timing of message delivery, and focus on the short-term effects of sun exposure such as sunburn and skin ageing should increase the acceptability of such messages to young people. Sun protection messages delivered to young adults via electronic media appear to be feasible and acceptable.

  1. Computerized pharmacy surveillance and alert system for drug-related problems.

    PubMed

    Ferrández, O; Urbina, O; Grau, S; Mateu-de-Antonio, J; Marin-Casino, M; Portabella, J; Mojal, S; Riu, M; Salas, E

    2017-04-01

    Because of the impact of drug-related problems (DRPs) on morbidity and mortality, there is a need for computerized strategies to increase drug safety. The detection and identification of the causes of potential DRPs can be facilitated by the incorporation of a pharmacy warning system (PWS) in the computerized prescriber order entry (CPOE) and its application in the routine validation of inpatient drug therapy. A limited number of studies have evaluated a clinical decision support system to monitor drug treatment. Most of these applications have utilized a small range of drugs with alerts and/or types of alert. The objective of this study was to describe the implementation of a PWS integrated in the electronic medical record (EMR). The PWS was developed in 2003-2004. Pharmacological information to generate drug alerts was entered on demographic data, drug dosage, laboratory tests related to the prescribed drug and drug combinations (interactions, duplications and necessary combinations). The PWS was applied in the prescription reviews conducted in patients admitted to the hospital in 2012. Information on 83% of the drugs included in the pharmacopeia was introduced into the PWS, allowing detection of 2808 potential DRPs, representing 79·1% of all potential DRPs detected during the study period. Twenty per cent of PWS DRPs were clinically relevant, requiring pharmacist intervention. The PWS detected most potential DRPs, thus increasing inpatient safety. The detection ability of the PWS was higher than that reported for other tools described in the literature. © 2017 John Wiley & Sons Ltd.

  2. Vehicle surge detection and pathway discrimination by pedestrians who are blind: Effect of adding an alert sound to hybrid electric vehicles on performance.

    PubMed

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle

    2012-05-01

    This study examined the effect of adding an artificially generated alert sound to a quiet vehicle on its detectability and localizability with 15 visually impaired adults. When starting from a stationary position, the hybrid electric vehicle with an alert sound was significantly more quickly and reliably detected than either the identical vehicle without such added sound or the comparable internal combustion engine vehicle. However, no significant difference was found between the vehicles in respect to how accurately the participants could discriminate the path of a given vehicle (straight vs. right turn). These results suggest that adding an artificial sound to a hybrid electric vehicle may help reduce delay in street crossing initiation by a blind pedestrian, but the benefit of such alert sound may not be obvious in determining whether the vehicle in his near parallel lane proceeds straight through the intersection or turns right in front of him.

  3. Vehicle surge detection and pathway discrimination by pedestrians who are blind: Effect of adding an alert sound to hybrid electric vehicles on performance

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle

    2012-01-01

    This study examined the effect of adding an artificially generated alert sound to a quiet vehicle on its detectability and localizability with 15 visually impaired adults. When starting from a stationary position, the hybrid electric vehicle with an alert sound was significantly more quickly and reliably detected than either the identical vehicle without such added sound or the comparable internal combustion engine vehicle. However, no significant difference was found between the vehicles in respect to how accurately the participants could discriminate the path of a given vehicle (straight vs. right turn). These results suggest that adding an artificial sound to a hybrid electric vehicle may help reduce delay in street crossing initiation by a blind pedestrian, but the benefit of such alert sound may not be obvious in determining whether the vehicle in his near parallel lane proceeds straight through the intersection or turns right in front of him. PMID:22707841

  4. Temperature measurement systems in wearable electronics

    NASA Astrophysics Data System (ADS)

    Walczak, S.; Gołebiowski, J.

    2014-08-01

    The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.

  5. The effect of the electronic medical record on nurses' work.

    PubMed

    Robles, Jane

    2009-01-01

    The electronic medical record (EMR) is a workplace reality for most nurses. Its advantages include a single consolidated record for each person; capacity for data interfaces and alerts; improved interdisciplinary communication; and evidence-based decision support. EMRs can add to work complexity, by forcing better documentation of previously unrecorded data and/or because of poor design. Well-designed and well-implemented computerized provider order entry (CPOE) systems can streamline nurses' work. Generational differences in acceptance of and facility with EMRs can be addressed through open, healthy communication.

  6. Traffic crash accidents in Tehran, Iran: Its relation with circadian rhythm of sleepiness.

    PubMed

    Sadeghniiat-Haghighi, Khosro; Yazdi, Zohreh; Moradinia, Mohsen; Aminian, Omid; Esmaili, Alireza

    2015-01-01

    Road traffic accidents are one of main problems in Iran. Multiple factors cause traffic accidents and the most important one is sleepiness. This factor, however, is given less attention in our country. Road traffic accidents relevant to sleepiness are studied. In this cross-sectional study, all road traffic accidents relevant to sleepiness, which were reported by police, were studied in Tehran province in 2009. The risk of road traffic accidents due to sleepiness was increased by more than sevenfold (odds ratio = 7.33) in low alertness hours (0:00-6:00) compared to other time of day. The risk of road traffic accidents due to sleepiness was decreased by 0.15-fold (odds ratio = 0.15) in hours with maximum of alertness (18:00-22:00) of circadian rhythm compared to other time of day. The occurrence of road traffic accidents due to sleepiness has significant statistical relations with driving during lowest point of alertness of circadian rhythm.

  7. Using Natural Language Processing to Extract Abnormal Results From Cancer Screening Reports.

    PubMed

    Moore, Carlton R; Farrag, Ashraf; Ashkin, Evan

    2017-09-01

    Numerous studies show that follow-up of abnormal cancer screening results, such as mammography and Papanicolaou (Pap) smears, is frequently not performed in a timely manner. A contributing factor is that abnormal results may go unrecognized because they are buried in free-text documents in electronic medical records (EMRs), and, as a result, patients are lost to follow-up. By identifying abnormal results from free-text reports in EMRs and generating alerts to clinicians, natural language processing (NLP) technology has the potential for improving patient care. The goal of the current study was to evaluate the performance of NLP software for extracting abnormal results from free-text mammography and Pap smear reports stored in an EMR. A sample of 421 and 500 free-text mammography and Pap reports, respectively, were manually reviewed by a physician, and the results were categorized for each report. We tested the performance of NLP to extract results from the reports. The 2 assessments (criterion standard versus NLP) were compared to determine the precision, recall, and accuracy of NLP. When NLP was compared with manual review for mammography reports, the results were as follows: precision, 98% (96%-99%); recall, 100% (98%-100%); and accuracy, 98% (96%-99%). For Pap smear reports, the precision, recall, and accuracy of NLP were all 100%. Our study developed NLP models that accurately extract abnormal results from mammography and Pap smear reports. Plans include using NLP technology to generate real-time alerts and reminders for providers to facilitate timely follow-up of abnormal results.

  8. Vaginal temperature measurement by a wireless sensor for predicting the onset of calving in Japanese Black cows.

    PubMed

    Sakatani, Miki; Sugano, Takaaki; Higo, Aiki; Naotsuka, Koji; Hojo, Takuo; Gessei, Satoru; Uehara, Hiroshi; Takenouchi, Naoki

    2018-04-15

    We evaluated the utility of the continuous measurement of vaginal temperature by a wireless sensor and wireless connection for predicting the onset of calving and for clarifying the relationships among dystocia, calf conditions, and temperature changes at a commercial beef cattle farm in Japan. A total of 625 effective delivery data was collected. The temperature sensor inserted to the vagina on 7 days before the expected due date and collected the vaginal temperature every 5 min. The sensor detected two alerts according to the temperature change, one was the vaginal temperature of 4 h moving average compared to the same time temperature of last two days decreased more than 0.4 °C (Alert 1) and the other was the rupture of the allantoic sac and the dropped sensor temperature reached to the ambient temperature (Alert 2). The detection rates of Alert 1 and Alert 2 were 88.3% and 99.4%, respectively. The average time between Alert 1 and Alert 2 (Time 1) was 22 h, and that between Alert 2 and delivery (Time 2) was 2 h. These results indicated that the continuous measurement of vaginal temperature is effective for predicting the calving time. The necessity of assistance was correlated with dystocia, calf birth weight (BW), sex, and gestation periods. Interestingly, the durations of Times 1 and 2 were also associated with dystocia. The calf BW, sex, and gestation periods affected the length of Time 2. Our findings indicate that the BW of the calf is the most important factor for dystocia risk, and that the continuous measurement of vaginal temperature could become a good indicator for predicting not only the onset of calving, but also the necessity of assistance. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. ElarmS Earthquake Early Warning System: 2017 Performance and New ElarmS Version 3.0 (E3)

    NASA Astrophysics Data System (ADS)

    Chung, A. I.; Henson, I. H.; Allen, R. M.; Hellweg, M.; Neuhauser, D. S.

    2017-12-01

    The ElarmS earthquake early warning (EEW) system has been successfully detecting earthquakes throughout California since 2007. ElarmS version 2.0 (E2) is one of the three algorithms contributing alerts to ShakeAlert, a public EEW system being developed by the USGS in collaboration with UC Berkeley, Caltech, University of Washington, and University of Oregon. E2 began operating in test mode in the Pacific Northwest in 2013, and since April of this year E2 has been contributing real-time alerts from Oregon and Washington to the ShakeAlert production prototype system as part of the ShakeAlert roll-out throughout the West Coast. Since it began operating west-coast-wide, E2 has correctly alerted on 5 events that matched ANSS catalog events with M≥4, missed 1 event with M≥4, and incorrectly created alerts for 5 false events with M≥4. The most recent version of the algorithm, ElarmS version 3.0 (E3), is a significant improvement over E2. It addresses some of the most problematic causes of false events for which E2 produced alerts, without impacting reliability in terms of matched and missed events. Of the 5 false events that were generated by E2 since April, 4 would have been suppressed by E3. In E3, we have added a filterbank teleseismic filter. By analyzing the amplitude of the waveform filtered in various passbands, it is possible to distinguish between local and teleseismic events. We have also added a series of checks to validate triggers and filter out spurious and S-wave triggers. Additional improvements to the waveform associator also improve detections. In this presentation, we describe the improvements and compare the performance of the current production (E2) and development (E3) versions of ElarmS over the past year. The ShakeAlert project is now working through a streamlining process to identify the best components of various algorithms and merge them. The ElarmS team is participating in this effort and we anticipate that much of E3 will continue in the final system.

  10. Validation of the CME Geomagnetic Forecast Alerts Under the COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Dumbović, Mateja; Srivastava, Nandita; Rao, Yamini K.; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-08-01

    Under the European Union 7th Framework Programme (EU FP7) project Coronal Mass Ejections and Solar Energetic Particles (COMESEP, http://comesep.aeronomy.be), an automated space weather alert system has been developed to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. The COMESEP alert system uses the automated detection tool called Computer Aided CME Tracking (CACTus) to detect potentially threatening CMEs, a drag-based model (DBM) to predict their arrival, and a CME geoeffectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, the DBM calculates its arrival time at Earth and the CGFT calculates its geomagnetic risk level. The geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geoeffectiveness, as well as an estimate of the geomagnetic storm duration. We present the evaluation of the CME risk level forecast with the COMESEP alert system based on a study of geoeffective CMEs observed during 2014. The validation of the forecast tool is made by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of the DBM and CGFT (independent tools available at the Hvar Observatory website, http://oh.geof.unizg.hr). The results indicate that the success rate of the forecast in its current form is unacceptably low for a realistic operation system. Human intervention improves the forecast, but the false-alarm rate remains unacceptably high. We discuss these results and their implications for possible improvement of the COMESEP alert system.

  11. Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease - Guinea, 2014-2015.

    PubMed

    Lee, Christopher T; Bulterys, Marc; Martel, Lise D; Dahl, Benjamin A

    2016-03-11

    The epidemic of Ebola virus disease (Ebola) in West Africa began in Guinea in late 2013 (1), and on August 8, 2014, the World Health Organization (WHO) declared the epidemic a Public Health Emergency of International Concern (2). Guinea was declared Ebola-free on December 29, 2015, and is under a 90 day period of enhanced surveillance, following 3,351 confirmed and 453 probable cases of Ebola and 2,536 deaths (3). Passive surveillance for Ebola in Guinea has been conducted principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert numbers operated by prefecture health departments or to a national toll-free call center. The national call center additionally functions as a source of public health information by responding to questions from the public about Ebola. To evaluate the sensitivity of the two systems and compare the sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined prefecture alerts database, as well as the national call center database, with the national viral hemorrhagic fever (VHF) database; the VHF database contains records of all known confirmed Ebola cases. Among 17,309 alert calls analyzed from the national call center, 71 were linked to 1,838 confirmed Ebola cases in the VHF database, yielding a sensitivity of 3.9%. The sensitivity of the national call center was highest in the capital city of Conakry (11.4%) and lower in other prefectures. In comparison, the local alerts system had a sensitivity of 51.1%. Local public health infrastructure plays an important role in surveillance in an epidemic setting.

  12. Variability of Diabetes Alert Dog Accuracy in a Real-World Setting

    PubMed Central

    Gonder-Frederick, Linda A.; Grabman, Jesse H.; Shepard, Jaclyn A.; Tripathi, Anand V.; Ducar, Dallas M.; McElgunn, Zachary R.

    2017-01-01

    Background: Diabetes alert dogs (DADs) are growing in popularity as an alternative method of glucose monitoring for individuals with type 1 diabetes (T1D). Only a few empirical studies have assessed DAD accuracy, with inconsistent results. The present study examined DAD accuracy and variability in performance in real-world conditions using a convenience sample of owner-report diaries. Method: Eighteen DAD owners (44.4% female; 77.8% youth) with T1D completed diaries of DAD alerts during the first year after placement. Diary entries included daily BG readings and DAD alerts. For each DAD, percentage hits (alert with BG ≤ 5.0 or ≥ 11.1 mmol/L; ≤90 or ≥200 mg/dl), percentage misses (no alert with BG out of range), and percentage false alarms (alert with BG in range) were computed. Sensitivity, specificity, positive likelihood ratio (PLR), and true positive rates were also calculated. Results: Overall comparison of DAD Hits to Misses yielded significantly more Hits for both low and high BG. Total sensitivity was 57.0%, with increased sensitivity to low BG (59.2%) compared to high BG (56.1%). Total specificity was 49.3% and PLR = 1.12. However, high variability in accuracy was observed across DADs, with low BG sensitivity ranging from 33% to 100%. Number of DADs achieving ≥ 60%, 65% and 70% true positive rates was 71%, 50% and 44%, respectively. Conclusions: DADs may be able to detect out-of-range BG, but variability across DADs is evident. Larger trials are needed to further assess DAD accuracy and to identify factors influencing the complexity of DAD accuracy in BG detection. PMID:28627305

  13. Alertness, performance and off-duty sleep on 8-hour and 12-hour night shifts in a simulated continuous operations control room setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.

    A growing number of nuclear power plants in the United States have adopted routine 12-hr shift schedules. Because of the potential impact that extended work shifts could have on safe and efficient power plant operation, the U.S. Nuclear Regulatory Commission funded research on 8-hr and 12-hr shifts at the Human Alertness Research Center (HARC) in Boston, Massachusetts. This report describes the research undertaken: a study of simulated 8-hr and 12-hr work shifts that compares alertness, speed, and accuracy at responding to simulator alarms, and relative cognitive performance, self-rated mood and vigor, and sleep-wake patterns of 8-hr versus 12-hr shift workers.

  14. Do dogs sense hypoglycaemia?

    PubMed

    Weber, K S; Roden, M; Müssig, K

    2016-07-01

    To summarize the current knowledge on the phenomenon of dogs, both trained and untrained, sensing hypoglycaemia and alerting their owners to it. Electronic databases were searched for all types of articles reporting on untrained or trained 'diabetes alert' dogs. Articles published up until December 2014 in the English or German language were included. Several case reports and observational studies provide evidence that animals can perform at a level above that attributable to chance, and may reliably detect low diurnal as well as nocturnal hypoglycaemic episodes. Behavioural changes in untrained dogs were reported during 38-100% of hypoglycaemic events experienced by their owners. The sensitivity and specificity of the performance of trained diabetes alert dogs sensing hypoglycaemia ranged from 22 to 100% and 71 to 90%, respectively. Additionally, 75-81% of patients with diabetes who owned a trained dog reported a subsequent improvement in their quality of life. Nevertheless, the available data are limited and heterogeneous because they rely on low patient numbers and survey-based studies prone to recall bias. Further research is needed to confirm the preliminary data on the reliability and mechanism underlying the dogs' abilities to detect hypoglycaemia, and its impact on patient outcomes. © 2015 Diabetes UK.

  15. An Electronic Medical Record Alert Intervention to Improve HPV Vaccination Among Eligible Male College Students at a University Student Health Center.

    PubMed

    Martin, Suzanne; Warner, Echo L; Kirchhoff, Anne C; Mooney, Ryan; Martel, Laura; Kepka, Deanna

    2018-02-16

    This pilot study aims to improve HPV vaccination for college aged males at a student health center. The first part of the study consisted of a focus group that assessed the barriers and facilitators of HPV vaccination among healthcare providers and clinic staff (N = 16). Providers reported missed opportunities for HPV vaccination. For the second part of the study, providers and staff reviewed medical records of patients ages 18-26 with student health insurance and with < 3 doses of the HPV vaccine at baseline (12/1/2014 to 7/31/2015) and follow-up (12/1/2015 to 7/31/2016). A computer-automated EMR alert was generated in the medical record of eligible male patients (N = 386). Z-scores were estimated for two-sample proportions to measure change in HPV vaccine rates at baseline and follow-up for males and females. HPV vaccine initiation rates increased among males (baseline: 5.2% follow-up: 25.1%, p < 0.001). This study shows that EMR alerts improved HPV vaccine initiation rates among insured college-aged males.

  16. MiBAlert-a new information tool to fight multidrug-resistant bacteria in the hospital setting.

    PubMed

    Olesen, Bente; Anhøj, Jacob; Rasmussen, Kenneth Palle; Mølbak, Kåre; Voldstedlund, Marianne

    2016-11-01

    Although the timely isolation of patients is an essential intervention to limit spread of drug-resistant bacteria, information about the colonization status is often unavailable or lost when patients are readmitted or transferred between hospitals. Therefore, carriers of drug resistant bacteria are not recognized sufficiently early, and proper and timely isolation precautions are not taken. Consequently, resistant bacteria of public health concerns including vancomycin resistant enterococci (VRE) and methicillin resistant Staphylococcus aureus (MRSA) can spread epidemically. To ensure timely identification and proper isolation of such patients we developed an automatic real-time alert of carriers of drug resistant bacteria. The aim of this paper is to describe the system, called MiBAlert, and share the initial experiences in connection with an outbreak of VRE in the greater Copenhagen area (the Capital region), Denmark. We obtained data on cases of VRE from hospitals in Copenhagen during the period when the first version of MiBAlert was implemented and log-data on the use of MiBAlert. Furthermore, a survey was conducted among 88 staff members to investigate their experiences of MiBAlert. The alert is a tool directed toward healthcare personnel accessing the electronic health record (EHR) and those further involved in the care and treatment of the patient. It is based on a web service using data from the national microbiological database, MiBa. MiBAlert is a real-time electronic non-intrusive alert generated automatically in the header of the EHR each time record is accessed. On February 15, 2015 a pilot version of MiBAlert was launched. All positive tests for VRE throughout 1year were shown with alert status by MiBAlert visible to all medical staff with access to EHR. The alert system was automatically updated directly in the EHR across the five hospitals in the Capital region. We found that the system performed satisfactorily, being operational 24/7 all 135 trial days, apart from 72min, for all the hospitals. Of the staff who responded to the survey, 82% considered that MiBAlert overall improved compliance with isolation precautions regarding VRE-positive patients. We found a marked decline of new patients infected or colonized with VRE concomitant with the implementation of MiBAlert and the survey results. We found that MiBAlert was a valuable tool in a bundle approach to counter a multiple hospital outbreak of VRE, and that it has a great potential to improve the control of other drug-resistant bacteria. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Examining Lead Exposures in California through State-Issued Health Alerts for Food Contamination and an Exposure-Based Candy Testing Program.

    PubMed

    Handley, Margaret A; Nelson, Kali; Sanford, Eric; Clarity, Cassidy; Emmons-Bell, Sophia; Gorukanti, Anuhandra; Kennelly, Patrick

    2017-10-26

    In California, the annual number of children under age 6 y of age with blood lead levels (BLL) ≥10μg/dL is estimated at over 1,000 cases, and up to 10,000 cases when BLL between 4.5 and 9.5 μg/dL are included. State-issued health alerts for food contamination provide one strategy for tracking sources of food-related lead exposures. As well, California passed legislation in 2006 for the Food and Drug Branch (FDB) of the state health department to test and identify lead in candy. This report presents health alert data from California over a 14-y period, compares data before and after the candy testing program began, and examines country of origin, ZIP code data, and time from candy testing to release of health alerts for lead-contaminated candies for 2011-2012. After 2007, health alerts issued for lead in candy and food increased significantly. Analysis of candy-testing data indicated that multiple counties and ZIP codes were affected. Seventeen candies with high lead concentrations were identified, resulting in rapid dissemination (<2wk) of health alerts to local health departments and community clinicians and to the public. Surveillance of lead exposures from state-based food and candy testing programs provides an opportunity to identify and immediately act to remove nonpaint sources of lead affecting children. https://doi.org/10.1289/EHP2582.

  18. Which Patients in the Emergency Department Should Receive Preexposure Prophylaxis? Implementation of a Predictive Analytics Approach.

    PubMed

    Ridgway, Jessica P; Almirol, Ellen A; Bender, Alvie; Richardson, Andrew; Schmitt, Jessica; Friedman, Eleanor; Lancki, Nicola; Leroux, Ivan; Pieroni, Nina; Dehlin, Jessica; Schneider, John A

    2018-05-01

    Emergency Departments (EDs) have the potential to play a crucial role in HIV prevention by identifying and linking high-risk HIV-negative clients to preexposure prophylaxis (PrEP) care, but it is difficult to perform HIV risk assessment for all ED patients. We aimed to develop and implement an electronic risk score to identify ED patients who are potential candidates for PrEP. Using electronic medical record (EMR) data, we used logistic regression to model the outcome of PrEP eligibility. We converted the model into an electronic risk score and incorporated it into the EMR. The risk score is automatically calculated at triage. For patients whose risk score is above a given threshold, an automated electronic alert is sent to an HIV prevention counselor who performs real time HIV prevention counseling, risk assessment, and PrEP linkage as appropriate. The electronic risk score includes the following EMR variables: age, gender, gender of sexual partner, chief complaint, and positive test for sexually transmitted infection in the prior 6 months. A risk score ≥21 has specificity of 80.6% and sensitivity of 50%. In the first 5.5 months of implementation, the alert fired for 180 patients, 34.4% (62/180) of whom were women. Of the 51 patients who completed risk assessment, 68.6% (35/51) were interested in PrEP, 17.6% (9/51) scheduled a PrEP appointment, and 7.8% (4/51) successfully initiated PrEP. The measured number of successful PrEP initiations is likely an underestimate, as it does include patients who initiated PrEP with outside providers or referred acquaintances for PrEP care.

  19. Advanced alerting features: displaying new relevant data and retracting alerts.

    PubMed Central

    Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.

    1997-01-01

    We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625

  20. Lay persons alerted by mobile application system initiate earlier cardio-pulmonary resuscitation: A comparison with SMS-based system notification.

    PubMed

    Caputo, Maria Luce; Muschietti, Sandro; Burkart, Roman; Benvenuti, Claudio; Conte, Giulio; Regoli, François; Mauri, Romano; Klersy, Catherine; Moccetti, Tiziano; Auricchio, Angelo

    2017-05-01

    We compared the time to initiation of cardiopulmonary resuscitation (CPR) by lay responders and/or first responders alerted either via Short Message Service (SMS) or by using a mobile application-based alert system (APP). The Ticino Registry of Cardiac Arrest collects all data about out-of-hospital cardiac arrests (OHCAs) occurring in the Canton of Ticino. At the time of a bystander's call, the EMS dispatcher sends one ambulance and alerts the first-responders network made up of police officers or fire brigade equipped with an automatic external defibrillator, the so called "traditional" first responders, and - if the scene was considered safe - lay responders as well. We evaluated the time from call to arrival of traditional first responders and/or lay responders when alerted either via SMS or the new developed mobile APP. Over the study period 593 OHCAs have occurred. Notification to the first responders network was sent via SMS in 198 cases and via mobile APP in 134 cases. Median time to first responder/lay responder arrival on scene was significantly reduced by the APP-based system (3.5 [2.8-5.2]) compared to the SMS-based system (5.6 [4.2-8.5] min, p 0.0001). The proportion of lay responders arriving first on the scene significantly increased (70% vs. 15%, p<0.01) with the APP. Earlier arrival of a first responder or of a lay responder determined a higher survival rate. The mobile APP system is highly efficient in the recruitment of first responders, significantly reducing the time to the initiation of CPR thus increasing survival rates. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Intelligent MONitoring System for antiviral pharmacotherapy in patients with chronic hepatitis C (SiMON-VC).

    PubMed

    Margusino-Framiñán, Luis; Cid-Silva, Purificación; Mena-de-Cea, Álvaro; Sanclaudio-Luhía, Ana Isabel; Castro-Castro, José Antonio; Vázquez-González, Guillermo; Martín-Herranz, Isabel

    2017-01-01

    Two out of six strategic axes of pharmaceutical care in our hospital are quality and safety of care, and the incorporation of information technologies. Based on this, an information system was developed in the outpatient setting for pharmaceutical care of patients with chronic hepatitis C, SiMON-VC, which would improve the quality and safety of their pharmacotherapy. The objective of this paper is to describe requirements, structure and features of Si- MON-VC. Requirements demanded were that the information system would enter automatically all critical data from electronic clinical records at each of the visits to the Outpatient Pharmacy Unit, allowing the generation of events and alerts, documenting the pharmaceutical care provided, and allowing the use of data for research purposes. In order to meet these requirements, 5 sections were structured for each patient in SiMON-VC: Main Record, Events, Notes, Monitoring Graphs and Tables, and Follow-up. Each section presents a number of tabs with those coded data needed to monitor patients in the outpatient unit. The system automatically generates alerts for assisted prescription validation, efficacy and safety of using antivirals for the treatment of this disease. It features a completely versatile Indicator Control Panel, where temporary monitoring standards and alerts can be set. It allows the generation of reports, and their export to the electronic clinical record. It also allows data to be exported to the usual operating systems, through Big Data and Business Intelligence. Summing up, we can state that SiMON-VC improves the quality of pharmaceutical care provided in the outpatient pharmacy unit to patients with chronic hepatitis C, increasing the safety of antiviral therapy. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  2. Great expectations: top-down attention modulates the costs of clutter and eccentricity.

    PubMed

    Steelman, Kelly S; McCarley, Jason S; Wickens, Christopher D

    2013-12-01

    An experiment and modeling effort examined interactions between bottom-up and top-down attentional control in visual alert detection. Participants performed a manual tracking task while monitoring peripheral display channels for alerts of varying salience, eccentricity, and spatial expectancy. Spatial expectancy modulated the influence of salience and eccentricity; alerts in low-probability locations engendered higher miss rates, longer detection times, and larger costs of visual clutter and eccentricity, indicating that top-down attentional control offset the costs of poor bottom-up stimulus quality. Data were compared to the predictions of a computational model of scanning and noticing that incorporates bottom-up and top-down sources of attentional control. The model accounted well for the overall pattern of miss rates and response times, predicting each of the observed main effects and interactions. Empirical results suggest that designers should expect the costs of poor bottom-up visibility to be greater for low expectancy signals, and that the placement of alerts within a display should be determined based on the combination of alert expectancy and response priority. Model fits suggest that the current model can serve as a useful tool for exploring a design space as a precursor to empirical data collection and for generating hypotheses for future experiments. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  3. Development and evaluation of a data-adaptive alerting algorithm for univariate temporal biosurveillance data.

    PubMed

    Elbert, Yevgeniy; Burkom, Howard S

    2009-11-20

    This paper discusses further advances in making robust predictions with the Holt-Winters forecasts for a variety of syndromic time series behaviors and introduces a control-chart detection approach based on these forecasts. Using three collections of time series data, we compare biosurveillance alerting methods with quantified measures of forecast agreement, signal sensitivity, and time-to-detect. The study presents practical rules for initialization and parameterization of biosurveillance time series. Several outbreak scenarios are used for detection comparison. We derive an alerting algorithm from forecasts using Holt-Winters-generalized smoothing for prospective application to daily syndromic time series. The derived algorithm is compared with simple control-chart adaptations and to more computationally intensive regression modeling methods. The comparisons are conducted on background data from both authentic and simulated data streams. Both types of background data include time series that vary widely by both mean value and cyclic or seasonal behavior. Plausible, simulated signals are added to the background data for detection performance testing at signal strengths calculated to be neither too easy nor too hard to separate the compared methods. Results show that both the sensitivity and the timeliness of the Holt-Winters-based algorithm proved to be comparable or superior to that of the more traditional prediction methods used for syndromic surveillance.

  4. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  5. Medication-related clinical decision support alert overrides in inpatients.

    PubMed

    Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W

    2018-05-01

    To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.

  6. Electronic rumble strip

    NASA Astrophysics Data System (ADS)

    Stauffer, Donald R.; Lenz, James

    1997-02-01

    Single vehicle run-off-road accidents are responsible for significant numbers of injuries and fatalities, and significant property damage. This fact spurs interest in warning systems to alert drivers that vehicles are drifting towards the edge of the road, and that a run-off road accident is imminent. An early attempt at such a warning system is the use of machined grooves on the shoulder to create a rumble strip. Such a system only provides warning, however, as the vehicle actually leaves the traffic lane. More desirable is a system that warns in anticipation of such departure. Honeywell has under development a magnetic lateral guidance system that couples a sensitive magnetoresistive transducer with a magnetic traffic marking tape being developed by 3M. While this development was initially undertaken for use in automated highways, or for special tasks such as guiding snowplow owners, the system can provide an effective, all-weather warning system to provide alert of impending departure from the roadway. This electronic rumble strip is actually a simpler system than the baseline guidance system, and can monitor both distance from the traffic lane edge and the speed of approach to the edge with a low cost sensor.

  7. Near-Earth asteroids: Observer alert network and physical observations

    NASA Technical Reports Server (NTRS)

    Davis, Donald R.; Chapman, Clark R.

    1992-01-01

    This project strives to obtain physical observations on newly discovered Near-Earth Objects (NEO's) in order to provide fundamental data needed to assess the resources available in the population. The goal is acquiring data on all objects brighter than magnitude V= 17.0. To accomplish this, an electronic mail alert and observer information service that informs observers around the world as to the status of physical observations on currently observable NEO's was established. Such data is also acquired ourselves through a cooperative program with European colleagues that uses telescopes on La Palma to obtain spectra of NEO's and through observations made from a local telescope on Tumamoc Hill. This latter telescope has the advantage that large amounts of observing time are available, so that whenever a new NEO's discovered, we can be assured of getting time to observe it.

  8. Differential effects of phasic and tonic alerting on the efficiency of executive attention.

    PubMed

    Asanowicz, Dariusz; Marzecová, Anna

    2017-05-01

    The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Evaluation of health alerts from an early illness warning system in independent living.

    PubMed

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  10. Alertness and cognitive control: Toward a spatial grouping hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.

  11. Evaluation of an intravenous preparation information system for improving the reconstitution and dilution process.

    PubMed

    Jo, Yun Hee; Shin, Wan Gyoon; Lee, Ju-Yeun; Yang, Bo Ram; Yu, Yun Mi; Jung, Sun Hoi; Kim, Hyang Sook

    2016-10-01

    There are very few studies reporting the impact of providing intravenous (IV) preparation information on quality use of antimicrobials, particularly regarding their reconstitution and dilution. Therefore, to improve these processes in IV antimicrobial administration, an IV preparation information system (IPIS) was implemented in a hospital. We aimed to evaluate the effect of improving reconstitution and dilution by implementing an IPIS in the electronic medical record (EMR) system. Prescriptions and activity records of nurses for injectable antimicrobials that required reconstitution and dilution for IV preparation from January 2008 to December 2013 were retrieved from EMR, and assessed based on packaging label information for reconstituting and diluting solutions. We defined proper reconstitution and dilution as occurring when the reconstitution and dilution solutions prescribed were consistent with the nurses' acting records. The types of intervention in the IPIS were as follows: a pop-up alert for proper reconstitution and passive guidance for proper dilution. We calculated the monthly proper reconstitution rate (PRR) and proper dilution rate (PDR) and evaluated the changes in these rates and trends using interrupted time series analyses. Prior to the initiation of the reconstitution alert and dilution information, the PRR and PDR were 12.7 and 46.1%, respectively. The reconstitution alert of the IPIS rapidly increased the PRR by 41% (p<0.001), after which the PRR decreased by 0.9% (p=0.013) per month after several months. However, there was no significant change in the rate or trend of the PDR during the study period. This study demonstrated that the provision of reconstitution alerts by the IPIS contributed to improving the reconstitution process of IV antimicrobial injection administration. However, providing passive information on dilution solutions was ineffective. Furthermore, solutions to ensure the continuous effectiveness of alert systems are warranted and should be actively sought. Copyright © 2016. Published by Elsevier Ireland Ltd.

  12. The Challenges of Electronic Health Records and Diabetes Electronic Prescribing: Implications for Safety Net Care for Diverse Populations

    PubMed Central

    Chan, Lenny L. S.; Fouts, Michelle M.; Murphy, Elizabeth J.

    2017-01-01

    Widespread electronic health record (EHR) implementation creates new challenges in the diabetes care of complex and diverse populations, including safe medication prescribing for patients with limited health literacy and limited English proficiency. This review highlights how the EHR electronic prescribing transformation has affected diabetes care for vulnerable patients and offers recommendations for improving patient safety through EHR electronic prescribing design, implementation, policy, and research. Specifically, we present evidence for (1) the adoption of RxNorm; (2) standardized naming and picklist options for high alert medications such as insulin; (3) the widespread implementation of universal medication schedule and language-concordant labels, with the expansion of electronic prescription 140-character limit; (4) enhanced bidirectional communication with pharmacy partners; and (5) informatics and implementation research in safety net healthcare systems to examine how EHR tools and practices affect diverse vulnerable populations. PMID:28197420

  13. The Challenges of Electronic Health Records and Diabetes Electronic Prescribing: Implications for Safety Net Care for Diverse Populations.

    PubMed

    Ratanawongsa, Neda; Chan, Lenny L S; Fouts, Michelle M; Murphy, Elizabeth J

    2017-01-01

    Widespread electronic health record (EHR) implementation creates new challenges in the diabetes care of complex and diverse populations, including safe medication prescribing for patients with limited health literacy and limited English proficiency. This review highlights how the EHR electronic prescribing transformation has affected diabetes care for vulnerable patients and offers recommendations for improving patient safety through EHR electronic prescribing design, implementation, policy, and research. Specifically, we present evidence for (1) the adoption of RxNorm; (2) standardized naming and picklist options for high alert medications such as insulin; (3) the widespread implementation of universal medication schedule and language-concordant labels, with the expansion of electronic prescription 140-character limit; (4) enhanced bidirectional communication with pharmacy partners; and (5) informatics and implementation research in safety net healthcare systems to examine how EHR tools and practices affect diverse vulnerable populations.

  14. Managing the Alert Process at NewYork-Presbyterian Hospital

    PubMed Central

    Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary

    2005-01-01

    Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073

  15. Does one hour of bright or short-wavelength filtered tablet screenlight have a meaningful effect on adolescents' pre-bedtime alertness, sleep, and daytime functioning?

    PubMed

    Heath, Melanie; Sutherland, Cate; Bartel, Kate; Gradisar, Michael; Williamson, Paul; Lovato, Nicole; Micic, Gorica

    2014-05-01

    Electronic media use is prevalent among adolescent populations, as is the frequency of sleeplessness. One mechanism proposed for technology affecting adolescents' sleep is the alerting effects from bright screens. Two explanations are provided. First, screens emit significant amounts of short-wavelength light (i.e. blue), which produces acute alertness and alters sleep timing. Second, later chronotypes are hypothesised to be hypersensitive to evening light. This study analysed the pre-sleep alertness (GO/NOGO task speed, accuracy; subjective sleepiness), sleep (sleep diary, polysomnography), and morning functioning of 16 healthy adolescents (M = 17.4 ± 1.9 yrs, 56% f) who used a bright tablet screen (80 lux), dim screen (1 lux) and a filtered short-wavelength screen (f.lux; 50 lux) for 1 hr before their usual bedtime in a within-subjects protocol. Chronotype was analysed as a continuous between-subjects factor; however, no significant interactions occurred. Significant effects occurred between bright and dim screens for GO/NOGO speed and accuracy. However, the magnitude of these differences was small (e.g. GO/NOGO speed = 23 ms, accuracy = 13%), suggesting minimal clinical significance. No significant effects were found for sleep onset latency, slow-rolling eye movements, or the number of SWS and REM minutes in the first two sleep cycles. Future independent studies are needed to test short (1 hr) vs longer (>2 hrs) screen usage to provide evidence for safe-to-harmful levels of screenlight exposure before adolescents' usual bedtime.

  16. Standard Anatomic Terminologies: Comparison for Use in a Health Information Exchange–Based Prior Computed Tomography (CT) Alerting System

    PubMed Central

    Lowry, Tina; Vreeman, Daniel J; Loo, George T; Delman, Bradley N; Thum, Frederick L; Slovis, Benjamin H; Shapiro, Jason S

    2017-01-01

    Background A health information exchange (HIE)–based prior computed tomography (CT) alerting system may reduce avoidable CT imaging by notifying ordering clinicians of prior relevant studies when a study is ordered. For maximal effectiveness, a system would alert not only for prior same CTs (exams mapped to the same code from an exam name terminology) but also for similar CTs (exams mapped to different exam name terminology codes but in the same anatomic region) and anatomically proximate CTs (exams in adjacent anatomic regions). Notification of previous same studies across an HIE requires mapping of local site CT codes to a standard terminology for exam names (such as Logical Observation Identifiers Names and Codes [LOINC]) to show that two studies with different local codes and descriptions are equivalent. Notifying of prior similar or proximate CTs requires an additional mapping of exam codes to anatomic regions, ideally coded by an anatomic terminology. Several anatomic terminologies exist, but no prior studies have evaluated how well they would support an alerting use case. Objective The aim of this study was to evaluate the fitness of five existing standard anatomic terminologies to support similar or proximate alerts of an HIE-based prior CT alerting system. Methods We compared five standard anatomic terminologies (Foundational Model of Anatomy, Systematized Nomenclature of Medicine Clinical Terms, RadLex, LOINC, and LOINC/Radiological Society of North America [RSNA] Radiology Playbook) to an anatomic framework created specifically for our use case (Simple ANatomic Ontology for Proximity or Similarity [SANOPS]), to determine whether the existing terminologies could support our use case without modification. On the basis of an assessment of optimal terminology features for our purpose, we developed an ordinal anatomic terminology utility classification. We mapped samples of 100 random and the 100 most frequent LOINC CT codes to anatomic regions in each terminology, assigned utility classes for each mapping, and statistically compared each terminology’s utility class rankings. We also constructed seven hypothetical alerting scenarios to illustrate the terminologies’ differences. Results Both RadLex and the LOINC/RSNA Radiology Playbook anatomic terminologies ranked significantly better (P<.001) than the other standard terminologies for the 100 most frequent CTs, but no terminology ranked significantly better than any other for 100 random CTs. Hypothetical scenarios illustrated instances where no standard terminology would support appropriate proximate or similar alerts, without modification. Conclusions LOINC/RSNA Radiology Playbook and RadLex’s anatomic terminologies appear well suited to support proximate or similar alerts for commonly ordered CTs, but for less commonly ordered tests, modification of the existing terminologies with concepts and relations from SANOPS would likely be required. Our findings suggest SANOPS may serve as a framework for enhancing anatomic terminologies in support of other similar use cases. PMID:29242174

  17. Validation of the CME Geomagnetic forecast alerts under COMESEP alert system

    NASA Astrophysics Data System (ADS)

    Dumbovic, Mateja; Srivastava, Nandita; Khodia, Yamini; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-04-01

    An automated space weather alert system has been developed under the EU FP7 project COMESEP (COronal Mass Ejections and Solar Energetic Particles: http://comesep.aeronomy.be) to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. COMESEP alert system uses automated detection tool CACTus to detect potentially threatening CMEs, drag-based model (DBM) to predict their arrival and CME geo-effectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, DBM calculates its arrival time at Earth and CGFT calculates its geomagnetic risk level. Geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geo-effectiveness, as well as an estimate of the geomagnetic-storm duration. We present the evaluation of the CME risk level forecast with COMESEP alert system based on a study of geo-effective CMEs observed during 2014. The validation of the forecast tool is done by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of DBM and CGFT (self standing tools available at Hvar Observatory website: http://oh.geof.unizg.hr). The results implicate that the success rate of the forecast is higher with human intervention and using more advanced tools. This work has received funding from the European Commission FP7 Project COMESEP (263252). We acknowledge the support of Croatian Science Foundation under the project 6212 „Solar and Stellar Variability".

  18. Daytime light exposure: effects on biomarkers, measures of alertness, and performance.

    PubMed

    Sahin, Levent; Wood, Brittany M; Plitnick, Barbara; Figueiro, Mariana G

    2014-11-01

    Light can elicit an alerting response in humans, independent from acute melatonin suppression. Recent studies have shown that red light significantly increases daytime and nighttime alertness. The main goal of the present study was to further investigate the effects of daytime light exposure on performance, biomarkers and measures of alertness. It was hypothesized that, compared to remaining in dim light, daytime exposure to narrowband long-wavelength (red) light or polychromatic (2568K) light would induce greater alertness and shorter response times. Thirteen subjects experienced three lighting conditions: dim light (<5lux), red light (λmax=631nm, 213lux, 1.1W/m(2)), and white light (2568K, 361lux, 1.1W/m(2)). The presentation order of the lighting conditions was counterbalanced across the participants and each participant saw a different lighting condition each week. Our results demonstrate, for the first time, that red light can increase short-term performance as shown by the significant (p<0.05) reduced response time and higher throughput in performance tests during the daytime. There was a significant decrease (p<0.05) in alpha power and alpha-theta power after exposure to the white light, but this alerting effect did not translate to better performance. Alpha power was significantly reduced after red light exposure in the middle of the afternoon. There was no significant effect of light on cortisol and alpha amylase. The present results suggest that red light can be used to increase daytime performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. The Role of the Right Dorsolateral Prefrontal Cortex in Phasic Alertness: Evidence from a Contingent Negative Variation and Repetitive Transcranial Magnetic Stimulation Study

    PubMed Central

    Mannarelli, Daniela; Pauletti, Caterina; Grippo, Antonello; Amantini, Aldo; Augugliaro, Vito; Currà, Antonio; Missori, Paolo; Locuratolo, Nicoletta; De Lucia, Maria C.; Rinalduzzi, Steno; Fattapposta, Francesco

    2015-01-01

    Phasic alertness represents the ability to increase response readiness to a target following an external warning stimulus. Specific networks in the frontal and parietal regions appear to be involved in the alert state. In this study, we examined the role of the right dorsolateral prefrontal cortex (DLPFC) during the attentional processing of a stimulus using a cued double-choice reaction time task. The evaluation of these processes was conducted by means of Event-Related Potentials (ERPs), in particular by using the Contingent Negative Variation (CNV), and repetitive 1-Hz Transcranial Magnetic Stimulation (rTMS). Transient virtual inhibition of the right DLPFC induced by real 1-Hz rTMS stimulation led to a significant decrease in total CNV and W1-CNV areas if compared with the basal and post-sham rTMS conditions. Reaction times (RTs) did not decrease after inhibitory rTMS, but they did improve after sham stimulation. These results suggest that the right DLPFC plays a crucial role in the genesis and maintenance of the alerting state and learning processes. PMID:26090234

  20. Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support

    PubMed Central

    Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E

    2011-01-01

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746

  1. Workplace lighting for improving alertness and mood in daytime workers.

    PubMed

    Pachito, Daniela V; Eckeli, Alan L; Desouky, Ahmed S; Corbett, Mark A; Partonen, Timo; Rajaratnam, Shantha Mw; Riera, Rachel

    2018-03-02

    Exposure to light plays a crucial role in biological processes, influencing mood and alertness. Daytime workers may be exposed to insufficient or inappropriate light during daytime, leading to mood disturbances and decreases in levels of alertness. To assess the effectiveness and safety of lighting interventions to improve alertness and mood in daytime workers. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, seven other databases; ClinicalTrials.gov and the World Health Organization trials portal up to January 2018. We included randomised controlled trials (RCTs), and non-randomised controlled before-after trials (CBAs) that employed a cross-over or parallel-group design, focusing on any type of lighting interventions applied for daytime workers. Two review authors independently screened references in two stages, extracted outcome data and assessed risk of bias. We used standardised mean differences (SMDs) and 95% confidence intervals (CI) to pool data from different questionnaires and scales assessing the same outcome across different studies. We combined clinically homogeneous studies in a meta-analysis. We used the GRADE system to rate quality of evidence. The search yielded 2844 references. After screening titles and abstracts, we considered 34 full text articles for inclusion. We scrutinised reports against the eligibility criteria, resulting in the inclusion of five studies (three RCTs and two CBAs) with 282 participants altogether. These studies evaluated four types of comparisons: cool-white light, technically known as high correlated colour temperature (CCT) light versus standard illumination; different proportions of indirect and direct light; individually applied blue-enriched light versus no treatment; and individually applied morning bright light versus afternoon bright light for subsyndromal seasonal affective disorder.We found no studies comparing one level of illuminance versus another.We found two CBA studies (163 participants) comparing high CCT light with standard illumination. By pooling their results via meta-analysis we found that high CCT light may improve alertness (SMD -0.69, 95% CI -1.28 to -0.10; Columbia Jet Lag Scale and the Karolinska Sleepiness Scale) when compared to standard illumination. In one of the two CBA studies with 94 participants there was no difference in positive mood (mean difference (MD) 2.08, 95% CI -0.1 to 4.26) or negative mood (MD -0.45, 95% CI -1.84 to 0.94) assessed using the Positive and Negative Affect Schedule (PANAS) scale. High CCT light may have fewer adverse events than standard lighting (one CBA; 94 participants). Both studies were sponsored by the industry. We graded the quality of evidence as very low.We found no studies comparing light of a particular illuminance and light spectrum or CCT versus another combination of illuminance and light spectrum or CCT.We found no studies comparing daylight versus artificial light.We found one RCT (64 participants) comparing the effects of different proportions of direct and indirect light: 100% direct lighting, 70% direct lighting plus 30% indirect lighting, 30% direct lighting plus 70% indirect lighting and 100% indirect lighting. There was no substantial difference in mood, as assessed by the Beck Depression Inventory, or in adverse events, such as ocular, reading or concentration problems, in the short or medium term. We graded the quality of evidence as low.We found two RCTs comparing individually administered light versus no treatment. According to one RCT with 25 participants, blue-enriched light individually applied for 30 minutes a day may enhance alertness (MD -3.30, 95% CI -6.28 to -0.32; Epworth Sleepiness Scale) and may improve mood (MD -4.8, 95% CI -9.46 to -0.14; Beck Depression Inventory). We graded the quality of evidence as very low. One RCT with 30 participants compared individually applied morning bright light versus afternoon bright light for subsyndromal seasonal affective disorder. There was no substantial difference in alertness levels (MD 7.00, 95% CI -10.18 to 24.18), seasonal affective disorder symptoms (RR 1.60, 95% CI 0.81, 3.20; number of participants presenting with a decrease of at least 50% in SIGH-SAD scores) or frequency of adverse events (RR 0.53, 95% CI 0.26 to 1.07). Among all participants, 57% had a reduction of at least 50% in their SIGH-SAD score. We graded the quality of evidence as low.Publication bias could not be assessed for any of these comparisons. There is very low-quality evidence based on two CBA studies that high CCT light may improve alertness, but not mood, in daytime workers. There is very low-quality evidence based on one CBA study that high CCT light may also cause less irritability, eye discomfort and headache than standard illumination. There is low-quality evidence based on one RCT that different proportions of direct and indirect light in the workplace do not affect alertness or mood. There is very low-quality evidence based on one RCT that individually applied blue-enriched light improves both alertness and mood. There is low-quality evidence based on one RCT that individually administered bright light during the afternoon is as effective as morning exposure for improving alertness and mood in subsyndromal seasonal affective disorder.

  2. Childrens Hospital Integrated Patient Electronic Record System Continuation (CHIPERS)

    DTIC Science & Technology

    2015-12-01

    of our interactive BPAs and order set technology. The Cumberland Group has been the primary consulting group assisting the entire inpatient and...to allow for continued BPA development and iteration during the upgrade period, while also effecting a seamless transition of BPA and order set...clinical decision support system. Our BPA logic includes: Severe Sepsis Alert Logic Summary: Age + Temperature + White Blood Cell and (lethargy or

  3. Clinical Decision Support to Implement CYP2D6 Drug-Gene Interaction.

    PubMed

    Caraballo, Pedro J; Parkulo, Mark; Blair, David; Elliott, Michelle; Schultz, Cloann; Sutton, Joseph; Rao, Padma; Bruflat, Jamie; Bleimeyer, Robert; Crooks, John; Gabrielson, Donald; Nicholson, Wayne; Rohrer Vitek, Carolyn; Wix, Kelly; Bielinski, Suzette J; Pathak, Jyotishman; Kullo, Iftikhar

    2015-01-01

    The level of CYP2D6 metabolic activity can be predicted by pharmacogenomic testing, and concomitant use of clinical decision support has the potential to prevent adverse effects from those drugs metabolized by this enzyme. Our initial findings after implementation of clinical decision support alerts integrated in the electronic health records suggest high feasibility, but also identify important challenges.

  4. Analyzing Information Seeking and Drug-Safety Alert Response by Health Care Professionals as New Methods for Surveillance

    PubMed Central

    Pernek, Igor; Stiglic, Gregor; Leskovec, Jure; Strasberg, Howard R; Shah, Nigam Haresh

    2015-01-01

    Background Patterns in general consumer online search logs have been used to monitor health conditions and to predict health-related activities, but the multiple contexts within which consumers perform online searches make significant associations difficult to interpret. Physician information-seeking behavior has typically been analyzed through survey-based approaches and literature reviews. Activity logs from health care professionals using online medical information resources are thus a valuable yet relatively untapped resource for large-scale medical surveillance. Objective To analyze health care professionals’ information-seeking behavior and assess the feasibility of measuring drug-safety alert response from the usage logs of an online medical information resource. Methods Using two years (2011-2012) of usage logs from UpToDate, we measured the volume of searches related to medical conditions with significant burden in the United States, as well as the seasonal distribution of those searches. We quantified the relationship between searches and resulting page views. Using a large collection of online mainstream media articles and Web log posts we also characterized the uptake of a Food and Drug Administration (FDA) alert via changes in UpToDate search activity compared with general online media activity related to the subject of the alert. Results Diseases and symptoms dominate UpToDate searches. Some searches result in page views of only short duration, while others consistently result in longer-than-average page views. The response to an FDA alert for Celexa, characterized by a change in UpToDate search activity, differed considerably from general online media activity. Changes in search activity appeared later and persisted longer in UpToDate logs. The volume of searches and page view durations related to Celexa before the alert also differed from those after the alert. Conclusions Understanding the information-seeking behavior associated with online evidence sources can offer insight into the information needs of health professionals and enable large-scale medical surveillance. Our Web log mining approach has the potential to monitor responses to FDA alerts at a national level. Our findings can also inform the design and content of evidence-based medical information resources such as UpToDate. PMID:26293444

  5. Analyzing Information Seeking and Drug-Safety Alert Response by Health Care Professionals as New Methods for Surveillance.

    PubMed

    Callahan, Alison; Pernek, Igor; Stiglic, Gregor; Leskovec, Jure; Strasberg, Howard R; Shah, Nigam Haresh

    2015-08-20

    Patterns in general consumer online search logs have been used to monitor health conditions and to predict health-related activities, but the multiple contexts within which consumers perform online searches make significant associations difficult to interpret. Physician information-seeking behavior has typically been analyzed through survey-based approaches and literature reviews. Activity logs from health care professionals using online medical information resources are thus a valuable yet relatively untapped resource for large-scale medical surveillance. To analyze health care professionals' information-seeking behavior and assess the feasibility of measuring drug-safety alert response from the usage logs of an online medical information resource. Using two years (2011-2012) of usage logs from UpToDate, we measured the volume of searches related to medical conditions with significant burden in the United States, as well as the seasonal distribution of those searches. We quantified the relationship between searches and resulting page views. Using a large collection of online mainstream media articles and Web log posts we also characterized the uptake of a Food and Drug Administration (FDA) alert via changes in UpToDate search activity compared with general online media activity related to the subject of the alert. Diseases and symptoms dominate UpToDate searches. Some searches result in page views of only short duration, while others consistently result in longer-than-average page views. The response to an FDA alert for Celexa, characterized by a change in UpToDate search activity, differed considerably from general online media activity. Changes in search activity appeared later and persisted longer in UpToDate logs. The volume of searches and page view durations related to Celexa before the alert also differed from those after the alert. Understanding the information-seeking behavior associated with online evidence sources can offer insight into the information needs of health professionals and enable large-scale medical surveillance. Our Web log mining approach has the potential to monitor responses to FDA alerts at a national level. Our findings can also inform the design and content of evidence-based medical information resources such as UpToDate.

  6. The NAS Alert System: A look at the first eight years

    USGS Publications Warehouse

    Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  7. Validation of an electronic surveillance system for acute lung injury.

    PubMed

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P < 0.001). ALI "sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  8. External modulation of the sustained attention network in traumatic brain injury.

    PubMed

    Richard, Nadine M; O'Connor, Charlene; Dey, Ayan; Robertson, Ian H; Levine, Brian

    2018-05-07

    Traumatic brain injury (TBI) is associated with impairments in processing speed as well as higher-level cognitive functions that depend on distributed neural networks, such as regulating and sustaining attention. Although exogenous alerting cues have been shown to support patients in sustaining attentive, goal-directed behavior, the neural correlates of this rehabilitative effect are unclear. The purpose of this study was to explore the effects of moderate to severe TBI on activity and functional connectivity in the well-documented right-lateralized frontal-subcortical-parietal sustained attention network, and to assess the effects of alerting cues. Using multivariate analysis of fMRI data, TBI patients and matched neurologically healthy (NH) comparison participants were scanned as they performed the Sustained Attention to Response Task (SART) in 60-s blocks, with or without exogenous cueing through brief auditory alerting tones. Results documented inefficient voluntary control of attention in the TBI patients, with reduced functional connectivity in the sustained attention network relative to NH participants. When alerting cues were present during the SART, however, functional connectivity increased and became comparable to activity patterns seen in the NH group. These findings provide novel evidence of a neural mechanism for the facilitatory effects of alerting cues on goal-directed behavior in patients with damaged attentional brain systems, and support their use in cognitive rehabilitation. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. L-theanine and caffeine improve task switching but not intersensory attention or subjective alertness.

    PubMed

    Einöther, Suzanne J L; Martens, Vanessa E G; Rycroft, Jane A; De Bruin, Eveline A

    2010-04-01

    Tea ingredients L-theanine and caffeine have repeatedly been shown to deliver unique cognitive benefits when consumed in combination. The current randomized, placebo-controlled, double-blind, cross-over study compared a combination of L-theanine (97 mg) and caffeine (40 mg) to a placebo on two attention tasks and a self-report questionnaire before, and 10 and 60 min after consumption. The combination of L-theanine and caffeine significantly improved attention on a switch task as compared to the placebo, while subjective alertness and intersensory attention were not improved significantly. The results support previous evidence that L-theanine and caffeine in combination can improve attention. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Awareness Enhancing and Monitoring Device plus Habit Reversal in the Treatment of Trichotillomania: An Open Feasibility Trial.

    PubMed

    Himle, Joseph A; Bybee, Deborah; O'Donnell, Lisa A; Weaver, Addie; Vlnka, Sarah; DeSena, Daniel T; Rimer, Jessica M

    2018-01-01

    Habit Reversal Therapy (HRT) is helpful for many persons suffering from trichotillomania. However successful habit reversal therapy requires awareness of hair pulling behaviors. Available methods to monitor hair pulling behaviors are less than ideal, particularly when sufferers are unaware of their pulling-related behaviors. This open feasibility trial included 20 persons with trichotillomania who were treated with nine weeks of HRT with experienced clinicians following a well-established HRT protocol. HRT was augmented with an electronic Awareness Enhancing and Monitoring Device (AEMD) designed to alert users of hand to head contact and to monitor the frequency of pulling-related behaviors. The AEMD included a neck unit and two wrist units, each equipped with vibrating alert functions. The results of the open trial revealed significant improvements in trichotillomania symptoms as measured by clinician and self-report rating scales. Most participants met study criteria for HRT completion and treatment effects were large. Participants reported that the AEMD, when operational, was effective in alerting participants to TTM-related behaviors. The monitoring function of the AEMD did not operate as designed. Subjective feedback focused on the AEMD concept was positive but AEMD reliability problems and complaints about the wearability the units were common. Recommendations for AEMD design modifications were included.

  11. [Patient safety in primary care: PREFASEG project].

    PubMed

    Catalán, Arantxa; Borrell, Francesc; Pons, Angels; Amado, Ester; Baena, José Miguel; Morales, Vicente

    2014-07-01

    The Institut Català de la Salut (ICS) has designed and integrated in electronic clinical station of primary care a new software tool to support the prescription of drugs, which can detect on-line certain medication errors. The software called PREFASEG (stands for Secure drug prescriptions) aims to prevent adverse events related to medication use in the field of primary health care (PHC). This study was made on the computerized medical record called CPT, which is used by all PHC physicians in our institution -3,750- and prescribing physicians through it. PREFASEG integrated in eCAP in July 2010 and six months later we performed a cross-sectional study to evaluate their usefulness and refine their design. The software alerts on-line in 5 dimensions: drug interactions, redundant treatments, allergies, contraindications of drugs with disease, and advises against drugs in over 75 years. PREFASEG generated 1,162,765 alerts (1 per 10 high treatment), with the detection of therapeutic duplication (62%) the most alerted. The overall acceptance rate is 35%, redundancies pharmacological (43%) and allergies (26%) are the most accepted. A total of 10,808 professionals (doctors and nurses) have accepted some of the recommendations of the program. PREFASEG is a feasible and highly efficient strategy to achieve an objective of Quality Plan for the NHS. Copyright © 2014. Published by Elsevier Espana.

  12. An Integrated Computerized Triage System in the Emergency Department

    PubMed Central

    Aronsky, Dominik; Jones, Ian; Raines, Bill; Hemphill, Robin; Mayberry, Scott R; Luther, Melissa A; Slusser, Ted

    2008-01-01

    Emergency department (ED) triage is a fast-paced process that prioritizes the allocation of limited health care resources to patients in greatest need. This paper describes the experiences with an integrated, computerized triage application. The system exchanges information with other information systems, including the ED patient tracking board, the longitudinal electronic medical record, the computerized provider order entry, and the medication reconciliation application. The application includes decision support capabilities such as assessing the patient’s acuity level, age-dependent alerts for vital signs, and clinical reminders. The browser-based system utilizes the institution’s controlled vocabulary, improves data completeness and quality, such as compliance with capturing required data elements and screening questions, initiates clinical processes, such as pneumococcal vaccination ordering, and reminders to start clinical pathways, issues alerts for clinical trial eligibility, and facilitates various reporting needs. The system has supported the triage documentation of >290,000 pediatric and adult patients. PMID:18999190

  13. Low momentum recoil detectors in CLAS12 at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Charles, Gabriel; CLAS Collaboration Collaboration

    2017-01-01

    Part of the experimental program in Hall B of the Jefferson Lab is dedicated to studying nucleon structure using DIS on nuclei and detecting low-momentum recoil particles in coincidence with the scattered electron. For this purpose, specially designed central detectors are required in place of the inner tracker of CLAS12 to detect particles with momenta below 100 MeV/c. We will present the status of the BONuS12 RTPC detector that will take data within the next 2 years. We will detail the main improvements made from the previous BONuS RTPC. In a second part, we will discuss another recoil experiment, called ALERT, that has been proposed to run in Hall B. The constraints being different, the recoil detector is based on a drift chamber and an array of scintillators. We will present the main differences between the two detectors and summarize the R&D performed to develop the ALERT detector.

  14. The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) randomized controlled trial: phase 1 results on dynamics of early intervention with remote monitoring.

    PubMed

    Boriani, Giuseppe; Da Costa, Antoine; Ricci, Renato Pietro; Quesada, Aurelio; Favale, Stefano; Iacopino, Saverio; Romeo, Francesco; Risi, Arnaldo; Mangoni di S Stefano, Lorenza; Navarro, Xavier; Biffi, Mauro; Santini, Massimo; Burri, Haran

    2013-08-21

    Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25(th)-75(th) percentile, 1-4) days vs 29 (25(th)-75(th) percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF).

  15. The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) Randomized Controlled Trial: Phase 1 Results on Dynamics of Early Intervention With Remote Monitoring

    PubMed Central

    Da Costa, Antoine; Ricci, Renato Pietro; Quesada, Aurelio; Favale, Stefano; Iacopino, Saverio; Romeo, Francesco; Risi, Arnaldo; Mangoni di S Stefano, Lorenza; Navarro, Xavier; Biffi, Mauro; Santini, Massimo; Burri, Haran

    2013-01-01

    Background Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. Objective The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. Methods In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. Results The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25th-75th percentile, 1-4) days vs 29 (25th-75th percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). Conclusions RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. Trial Registration Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF). PMID:23965236

  16. A comparison of behavior for two cohorts of captive-reared greater sandhill cranes released in northern Arizona

    USGS Publications Warehouse

    Mummert, D.P.; Chambers, C.L.; Ellis, D.H.

    2001-01-01

    To determine how the behavior of greater sandhill cranes (Grus canadensis tabida) changes according to time of year, time of day, and number of days after release, we observed the activities of 2 groups of captive-reared greater sandhill cranes at Mormon Lake, northern Arizona. The behaviors we compared were alert, loafing, sleeping, foraging, preening, locomotion, and other. We found costume-reared subadult greater sandhill cranes that were established at the study site for a year spent more time foraging and being alert towards predators than parent-reared juvenile greater sandhill cranes that were recently released from captivity. We also found that with time juvenile sandhill cranes were increasingly alert and spent less time loafing. It appeared that captive-reared juvenile sandhill cranes learn behavior important for survival from previously released captive-reared cranes.

  17. Attention Network Dysfunction in Bulimia Nervosa - An fMRI Study

    PubMed Central

    Dahmen, Brigitte; Schulte-Rüther, Martin; Legenbauer, Tanja; Herpertz-Dahlmann, Beate; Konrad, Kerstin

    2016-01-01

    Objective Recent evidence has suggested an increased rate of comorbid ADHD and subclinical attentional impairments in bulimia nervosa (BN) patients. However, little is known regarding the underlying neural mechanisms of attentional functions in BN. Method Twenty BN patients and twenty age- and weight-matched healthy controls (HC) were investigated using a modified version of the Attention Network Task (ANT) in an fMRI study. This design enabled an investigation of the neural mechanisms associated with the three attention networks involved in alerting, reorienting and executive attention. Results The BN patients showed hyperactivation in parieto-occipital regions and reduced deactivation of default-mode-network (DMN) areas during alerting compared with HCs. Posterior cingulate activation during alerting correlated with the severity of eating-disorder symptoms within the patient group. Conversely, BN patients showed hypoactivation during reorienting and executive attention in anterior cingulate regions, the temporo-parietal junction (TPJ) and parahippocampus compared with HCs, which was negatively associated with global ADHD symptoms and impulsivity, respectively. Discussion Our findings demonstrate altered brain mechanisms in BN associated with all three attentional networks. Failure to deactivate the DMN and increased parieto-occipital activation required for alerting might be associated with a constant preoccupation with food or body image-related thoughts. Hypoactivation of executive control networks and TPJ might increase the likelihood of inattentive and impulsive behaviors and poor emotion regulation. Thus, dysfunction in the attentional network in BN goes beyond an altered executive attentional domain and needs to be considered in the diagnosis and treatment of BN. PMID:27607439

  18. The effect of phasic auditory alerting on visual perception.

    PubMed

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system-A survey of users.

    PubMed

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D

    2018-01-01

    Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.

  20. A Comparison of Blue Light and Caffeine Effects on Cognitive Function and Alertness in Humans

    PubMed Central

    Beaven, C. Martyn; Ekström, Johan

    2013-01-01

    The alerting effects of both caffeine and short wavelength (blue) light have been consistently reported. The ability of blue light to enhance alertness and cognitive function via non-image forming neuropathways have been suggested as a non-pharmacological countermeasure for drowsiness across a range of occupational settings. Here we compare and contrast the alerting and psychomotor effects of 240 mg of caffeine and a 1-h dose of ~40 lx blue light in a non-athletic population. Twenty-one healthy subjects performed a computer-based psychomotor vigilance test before and after each of four randomly assigned trial conditions performed on different days: white light/placebo; white light/240 mg caffeine; blue light/placebo; blue light/240 mg caffeine. The Karolinska Sleepiness Scale was used to assess subjective measures of alertness. Both the caffeine only and blue light only conditions enhanced accuracy in a visual reaction test requiring a decision and an additive effect was observed with respect to the fastest reaction times. However, in a test of executive function, where a distraction was included, caffeine exerted a negative effect on accuracy. Furthermore, the blue light only condition consistently outperformed caffeine when both congruent and incongruent distractions were presented. The visual reactions in the absence of a decision or distraction were also enhanced in the blue light only condition and this effect was most prominent in the blue-eyed participants. Overall, blue light and caffeine demonstrated distinct effects on aspects of psychomotor function and have the potential to positively influence a range of settings where cognitive function and alertness are important. Specifically, despite the widespread use of caffeine in competitive sporting environments, the possible impact of blue light has received no research attention. PMID:24282477

  1. Event-based internet biosurveillance: relation to epidemiological observation

    PubMed Central

    2012-01-01

    Background The World Health Organization (WHO) collects and publishes surveillance data and statistics for select diseases, but traditional methods of gathering such data are time and labor intensive. Event-based biosurveillance, which utilizes a variety of Internet sources, complements traditional surveillance. In this study we assess the reliability of Internet biosurveillance and evaluate disease-specific alert criteria against epidemiological data. Methods We reviewed and compared WHO epidemiological data and Argus biosurveillance system data for pandemic (H1N1) 2009 (April 2009 – January 2010) from 8 regions and 122 countries to: identify reliable alert criteria among 15 Argus-defined categories; determine the degree of data correlation for disease progression; and assess timeliness of Internet information. Results Argus generated a total of 1,580 unique alerts; 5 alert categories generated statistically significant (p < 0.05) correlations with WHO case count data; the sum of these 5 categories was highly correlated with WHO case data (r = 0.81, p < 0.0001), with expected differences observed among the 8 regions. Argus reported first confirmed cases on the same day as WHO for 21 of the first 64 countries reporting cases, and 1 to 16 days (average 1.5 days) ahead of WHO for 42 of those countries. Conclusion Confirmed pandemic (H1N1) 2009 cases collected by Argus and WHO methods returned consistent results and confirmed the reliability and timeliness of Internet information. Disease-specific alert criteria provide situational awareness and may serve as proxy indicators to event progression and escalation in lieu of traditional surveillance data; alerts may identify early-warning indicators to another pandemic, preparing the public health community for disease events. PMID:22709988

  2. Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy

    DTIC Science & Technology

    2012-03-01

    for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification

  3. Wireless Emergency Alerts (WEA) Cybersecurity Risk Management Strategy for Alert Originators

    DTIC Science & Technology

    2014-03-01

    formerly known as the Commercial Mobile Alert Service ( CMAS ) RDT&E program, is a collaborative partnership that includes the cellular industry, the...Examples illustrate a STRIDE analysis of the generic mission 1 The CMAS Alerting Pipeline Taxonomy describes in detail a hierarchical classification...SEI-2013-SR-018 | 1 1 Introduction The Wireless Emergency Alerts (WEA) service, formerly known as the Commercial Mobile Alert Service ( CMAS ), is a

  4. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...

  5. Temporal and other factors that influence the time doctors take to prescribe using an electronic prescribing system

    PubMed Central

    Coleman, Jamie J; Hodson, James; Thomas, Sarah K; Brooks, Hannah L; Ferner, Robin E

    2015-01-01

    Background A computerized physician order entry (CPOE) system with embedded clinical decision support can reduce medication errors in hospitals, but might increase the time taken to generate orders. Aims We aimed to quantify the effects of temporal (month, day of week, hour of shift) and other factors (grade of doctor, prior experience with the system, alert characteristics, and shift type) on the time taken to generate a prescription order. Setting A large university teaching hospital using a locally developed CPOE system with an extensive audit database. Design We retrospectively analyzed prescription orders from the audit database between August 2011 and July 2012. Results The geometric mean time taken to generate a prescription order within the CPOE system was 11.75 s (95% CI 11.72 to 11.78). Time to prescribe was most affected by the display of high-level (24.59 s (24.43 to 24.76); p<0.001) or previously unseen (18.87 s (18.78 to 18.96); p<0.001) alerts. Prescribers took significantly less time at weekends (11.29 s (11.23 to 11.35)) than on weekdays (11.88 s (11.84 to 11.91); p<0.001), in the first (11.25 s (11.16 to 11.34); p<0.001) and final (11.56 s (11.47 to 11.66); p<0.001) hour of their shifts, and after the first month of using the system. Conclusions The display of alerts, prescribing experience, system familiarity, and environment all affect the time taken to generate a prescription order. Our study reinforces the need for appropriate alerts to be presented to individuals at an appropriate place in the workflow, in order to improve prescribing efficiency. PMID:25074989

  6. Analysis of sex differences in preadmission management of ST-segment elevation (STEMI) myocardial infarction.

    PubMed

    Greenberg, Marna Rayl; Miller, Andrew C; Mackenzie, Richard S; Richardson, David M; Ahnert, Amy M; Sclafani, Mia J; Jozefick, Jennifer L; Goyke, Terrence E; Rupp, Valerie A; Burmeister, David B

    2012-10-01

    Many reports suggest gender disparity in cardiac care as a contributor to the increased mortality among women with heart disease. We sought to identify gender differences in the management of Myocardial Infarction (MI) Alert-activated ST-segment elevation myocardial infarction (STEMI) patients that may have resulted from prehospital initiation. A retrospective database was created for MI Alert STEMI patients who presented to the emergency department (ED) of an academic community hospital with 74,000 annual visits from April 2000 through December 2008. Included were patients meeting criteria for an MI Alert (an institutional clinical practice guideline designed to expedite cardiac catheterization for STEMI patients). Data points (before and after initiation of a prehospital alert protocol) were compared and used as markers of therapy: time to ECG, receiving β-blockers, and time to the catheterization laboratory (cath lab). Differences in categorical variables by patient sex were assessed using the χ(2) test. Medians were estimated as the measure of central tendency. Quantile regression models were used to assess differences in median times between subgroups. A total of 1231 MI Alert charts were identified and analyzed. The majority of the study population were male (70%), arrived at the ED via ambulance (60.1%), and were taking a β-blocker (67.8%) or aspirin (91.6%) at the time of the ED admission. Female patients were more likely than male patients to arrive at the ED via ambulance (65.9% vs 57.6%, respectively; P = 0.014). The median age of female patients was 68 years, whereas male patients were significantly younger (median age, 59 years; P < 0.001). The proportion of patients currently taking a β-blocker or low-dose aspirin did not vary by gender. Overall, 78.2% of the MI Alert patients arriving at the ED were MI2 (alert initiated by ED physician), and this did not vary by gender (P = 0.33). A total of 1064 MI Alert patients went to the cath lab: 766 male patients (88.9%) and 298 female patients (80.8%). Overall, the median time to cath lab arrival was 79 minutes for men and 81 minutes for women (P = 0.38). Overall, the median time to cath lab arrival significantly decreased from MI1 to MI3, (P(trend) < 0.001). For prehospital-initiated alerts (MI3), the median time to cath lab arrival was the same for men and women (64 minutes; P = 1.0). For hospital-initiated alerts, time to cath lab arrival was 82 minutes for male patients and 84 minutes for female patients (P = 0.38). Prehospital activation of the process decreased the time to the cath lab by 19 minutes (P < 0.001; 95% CI, 13.2-24.8). No significant gender differences were apparent in the STEMI patients analyzed, whether the MI Alert was initiated in the ED or prehospital initiated. Initiating prehospital-based alerts significantly decreased the time to the cath lab. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.

  7. An Analysis of Federal Airport and Air Carrier Employee Access Control, Screening. and Training Regulations

    DTIC Science & Technology

    1998-03-01

    traveling public, air carriers, and persons employed by or conducting business at public airports. 14. SUBJECT TERMS Airport Security , Federal...26 4. Sterile Area 28 5. Exclusive Area 28 E. SECURITY ALERT LEVELS 29 F. AIRPORT SECURITY TOOLS 30 1. Electronic Detection System 31 a... Security Coordinator ASP Airport Security Program BIS Biometrie Identification System CCTV Closed Circuit Television CJIS Criminal Justice Information

  8. Use of computer decision support in an antimicrobial stewardship program (ASP).

    PubMed

    Evans, R S; Olson, J A; Stenehjem, E; Buckel, W R; Thorell, E A; Howe, S; Wu, X; Jones, P S; Lloyd, J F

    2015-01-01

    Document information needs, gaps within the current electronic applications and reports, and workflow interruptions requiring manual information searches that decreased the ability of our antimicrobial stewardship program (ASP) at Intermountain Healthcare (IH) to prospectively audit and provide feedback to clinicians to improve antimicrobial use. A framework was used to provide access to patient information contained in the electronic medical record, the enterprise-wide data warehouse, the data-driven alert file and the enterprise-wide encounter file to generate alerts and reports via pagers, emails and through the Centers for Diseases and Control's National Healthcare Surveillance Network. Four new applications were developed and used by ASPs at Intermountain Medical Center (IMC) and Primary Children's Hospital (PCH) based on the design and input from the pharmacists and infectious diseases physicians and the new Center for Diseases Control and Prevention/National Healthcare Safety Network (NHSN) antibiotic utilization specifications. Data from IMC and PCH now show a general decrease in the use of drugs initially targeted by the ASP at both facilities. To be effective, ASPs need an enormous amount of "timely" information. Members of the ASP at IH report these new applications help them improve antibiotic use by allowing efficient, timely review and effective prioritization of patients receiving antimicrobials in order to optimize patient care.

  9. NOAA Weather Wire Service

    Science.gov Websites

    & Imagery; includes NWS alerts and warnings No 6 Wireless Emergency Alerts (WEA) Mobile Phone Alerts & Warnings only No 7 Interactive NWS (iNWS) - NOTE 1 https://inws.ncep.noaa.gov/ Mobile Phone $$$$) Internet/ Mobile Phone Alerts and Warnings No 15 County or Local Emergency Management Telephone alert

  10. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector... Special Fraud Alert. Specifically, the Updated Special Fraud Alert addressed the statutory provision...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  11. Physician Perspectives of CYP2C19 and Clopidogrel Drug-Gene Interaction Active Clinical Decision Support Alerts

    PubMed Central

    Nishimura, Adam A.; Shirts, Brian H.; Salama, Joseph; Smith, Joe W.; Devine, Beth; Tarczy-Hornoch, Peter

    2015-01-01

    Objective To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. Materials and Methods 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Results Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Principal Conclusions Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. PMID:26642939

  12. Physician perspectives of CYP2C19 and clopidogrel drug-gene interaction active clinical decision support alerts.

    PubMed

    Nishimura, Adam A; Shirts, Brian H; Salama, Joseph; Smith, Joe W; Devine, Beth; Tarczy-Hornoch, Peter

    2016-02-01

    To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system—A survey of users

    PubMed Central

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M.; Santen-Reestman, Jacqueline; Taxis, Katja

    2018-01-01

    Introduction Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. Objective To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. Methods In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Results Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. ‘Alert fatigue’ was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Conclusion Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue. PMID:29813099

  14. An evaluation of three processing methods and the effect of reduced culture times for faster direct identification of pathogens from BacT/ALERT blood cultures by MALDI-TOF MS.

    PubMed

    Loonen, A J M; Jansz, A R; Stalpers, J; Wolffs, P F G; van den Brule, A J C

    2012-07-01

    Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria from agar media. Direct identification from positive blood cultures should decrease the time to obtaining the result. In this study, three different processing methods for the rapid direct identification of bacteria from positive blood culture bottles were compared. In total, 101 positive aerobe BacT/ALERT bottles were included in this study. Aliquots from all bottles were used for three bacterial processing methods, i.e. the commercially available Bruker's MALDI Sepsityper kit, the commercially available Molzym's MolYsis Basic5 kit and a centrifugation/washing method. In addition, the best method was used to evaluate the possibility of MALDI application after a reduced incubation time of 7 h of Staphylococcus aureus- and Escherichia coli-spiked (1,000, 100 and 10 colony-forming units [CFU]) aerobe BacT/ALERT blood cultures. Sixty-six (65%), 51 (50.5%) and 79 (78%) bottles were identified correctly at the species level when the centrifugation/washing method, MolYsis Basic 5 and Sepsityper were used, respectively. Incorrect identification was obtained in 35 (35%), 50 (49.5%) and 22 (22%) bottles, respectively. Gram-positive cocci were correctly identified in 33/52 (64%) of the cases. However, Gram-negative rods showed a correct identification in 45/47 (96%) of all bottles when the Sepsityper kit was used. Seven hours of pre-incubation of S. aureus- and E. coli-spiked aerobe BacT/ALERT blood cultures never resulted in reliable identification with MALDI-TOF MS. Sepsityper is superior for the direct identification of microorganisms from aerobe BacT/ALERT bottles. Gram-negative pathogens show better results compared to Gram-positive bacteria. Reduced incubation followed by MALDI-TOF MS did not result in faster reliable identification.

  15. Comparison of BacT/Alert FAN and FAN Plus Bottles with Conventional Medium for Culturing Cerebrospinal Fluid.

    PubMed

    Yoo, In Young; Chun, Sejong; Song, Dong Joon; Huh, Hee Jae; Lee, Nam Yong

    2016-11-01

    We compared the BacT/Alert system FAN and FAN Plus media to conventional media for culturing cerebrospinal fluid (CSF) with 2,545 samples. FAN/FAN Plus bottles showed better performance for isolating microorganisms in CSF than conventional media (positive rate, 7.2% [182/2,545] versus 3.1% [80/2,545]). The incremental recovery rate of Cryptococcus neoformans from FAN Plus bottles was higher than that from FAN bottles. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  16. Mid-Infrared Properties of the Swift Burst Alert Telescope Active Galactic Nuclei Sample of the Local Universe. 1. Emission-Line Diagnostics

    DTIC Science & Technology

    2010-06-20

    reserved. Printed in the U.S.A. MID-INFRARED PROPERTIES OF THE SWIFT BURST ALERT TELESCOPE ACTIVE GALACTIC NUCLEI SAMPLE OF THE LOCAL UNIVERSE . I. EMISSION... the AGNs. We also compare the mid-infrared emission lines in the BAT AGNs with those from published studies of ULIRGs, Palomar- Green quasars, star...supermassive black holes (e.g., Rees 1984; Peterson et al. 2004). One way to approach the study of AGNs is to concentrate on those in the local universe

  17. Which components of health information technology will drive financial value?

    PubMed

    Kern, Lisa M; Wilcox, Adam; Shapiro, Jason; Dhopeshwarkar, Rina V; Kaushal, Rainu

    2012-08-01

    The financial effects of electronic health records (EHRs) and health information exchange (HIE) are largely unknown, despite unprecedented federal incentives for their use. We sought to understand which components of EHRs and HIE are most likely to drive financial savings in the ambulatory, inpatient, and emergency department settings. Framework development and a national expert panel. We searched the literature to identify functionalities enabled by EHRs and HIE across the 3 healthcare settings. We rated each of 233 functionality-setting combinations on their likelihood of having a positive financial effect. We validated the top-scoring functionalities with a panel of 28 national experts, and we compared the high-scoring functionalities with Stage 1 meaningful use criteria. We identified 54 high-scoring functionality- setting combinations, 27 for EHRs and 27 for HIE. Examples of high-scoring functionalities included providing alerts for expensive medications, providing alerts for redundant lab orders, sending and receiving imaging reports, and enabling structured medication reconciliation. Of the 54 high-scoring functionalities, 25 (46%) are represented in Stage 1 meaningful use. Many of the functionalities not yet represented in meaningful use correspond with functionalities that focus directly on healthcare utilization and costs rather than on healthcare quality per se. This work can inform the development and selection of future meaningful use measures; inform implementation efforts, as clinicians and hospitals choose from among a "menu" of measures for meaningful use; and inform evaluation efforts, as investigators seek to measure the actual financial impact of EHRs and HIE.

  18. Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples.

    PubMed

    Congestrì, Francesco; Pedna, Maria Federica; Fantini, Michela; Samuelli, Michela; Schiavone, Pasqua; Torri, Arianna; Bertini, Stefania; Sambri, Vittorio

    2017-09-01

    The early detection of bacteraemia and fungemia is of paramount importance to guide antimicrobial therapy in septic patients. In this study the 'time to detection' (TTD) value for the new blood culture system BacT/ALERT VIRTUO (VIRTUO) was evaluated in 1462 positive clinical bottles and compared with the TTD for 1601 positive clinical bottles incubated in the BacT/ALERT 3D system (BTA-3D). The most representative microorganisms isolated from bottles incubated in both blood culture systems were divided into eight categories (in order of frequency): coagulase-negative staphylococci (CoNS), Escherichia coli, Enterobacteriaceae (other than E. coli), Staphylococcus aureus, Enterococcus spp, viridans group streptococci, Pseudomonas aeruginosa, and Candida spp. The comparison of TTD values for the two blood culture systems strongly indicated that growth of the first five groups listed above was detected earlier with VIRTUO than with BTA-3D (p < 0.05). The new VIRTUO blood culture system can reduce the TTD for more than 75% of isolated microorganisms. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor

    2016-01-01

    A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.

  20. Temporal Precedence Checking for Switched Models and its Application to a Parallel Landing Protocol

    NASA Technical Reports Server (NTRS)

    Duggirala, Parasara Sridhar; Wang, Le; Mitra, Sayan; Viswanathan, Mahesh; Munoz, Cesar A.

    2014-01-01

    This paper presents an algorithm for checking temporal precedence properties of nonlinear switched systems. This class of properties subsume bounded safety and capture requirements about visiting a sequence of predicates within given time intervals. The algorithm handles nonlinear predicates that arise from dynamics-based predictions used in alerting protocols for state-of-the-art transportation systems. It is sound and complete for nonlinear switch systems that robustly satisfy the given property. The algorithm is implemented in the Compare Execute Check Engine (C2E2) using validated simulations. As a case study, a simplified model of an alerting system for closely spaced parallel runways is considered. The proposed approach is applied to this model to check safety properties of the alerting logic for different operating conditions such as initial velocities, bank angles, aircraft longitudinal separation, and runway separation.

  1. Hemochromatosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Bronchiectasis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Tracheostomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  4. Palpitations

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  5. Thalassemias

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  6. Cardioversion

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  7. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  8. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  9. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  10. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...

  11. Implications of resolved hypoxemia on the utility of desaturation alerts sent from an anesthesia decision support system to supervising anesthesiologists.

    PubMed

    Epstein, Richard H; Dexter, Franklin

    2012-10-01

    Hypoxemia (oxygen saturation <90%) lasting 2 or more minutes occurs in 6.8% of adult patients undergoing noncardiac anesthesia in operating room settings. Alarm management functionality can be added to decision support systems (DSS) to send text alerts about vital signs outside specified thresholds, using data in anesthesia information management systems. We considered enhancing our DSS to send hypoxemia alerts to the text pagers of supervising anesthesiologists. As part of a voluntary application for an investigative device exemption from our IRB to implement such functionality, we evaluated the maximum potential utility of such an alert system. Pulse oximetry values (Spo(2)) were extracted from our anesthesia information management systems for all cases performed in our main operating rooms and ambulatory surgical center between September 1, 2011, and February 4, 2012 (n = 16,870). Hypoxemic episodes (Spo(2) < 90%) were characterized as either (a) lasting one or more minutes or (b) lasting 2 or more minutes. A single simulated "alert" was modeled as having been sent at the timestamp of the first (a) or the second (b) hypoxemic value. The hypoxemic episode was considered resolved at 1, 3, or 5 minutes after the time of the alert if the Spo(2) value was no longer below the 90% threshold. Two-sided 99% conservative confidence limits were calculated for the percentage of unresolved alerts at the 3 evaluation intervals and compared with 70%, the lower limit of an acceptable true alarm rate for clinical utility. There was at least 1 hypoxemic episode lasting 1 minute or longer in 23% of cases, and at least 1 episode lasting 2 minutes or longer in 8% of cases. Only 7% (99% confidence interval [CI] 6% to 8%) of the 1-minute hypoxemic episodes were unresolved after 3 minutes, and only 8% (99% CI 6%to 9%) of 2-minute episodes after 5 minutes (both P < 10(-6) in comparison with 70% minimum reliability rate). Low utility should be expected for a DSS sending hypoxemia alerts to supervising anesthesiologists, because nearly all hypoxemic episodes will have been resolved before arrival of the anesthesiologist in the operating room. These results suggest that the principal research focus should be on developing more sophisticated alerts and processes within rooms for the anesthesia care provider to initiate treatment promptly, to interpret or correct artifacts, and to make it easier to call for assistance via a rapid communication system.

  12. Diabetes risk reduction in overweight first degree relatives of type 2 diabetes patients: effects of a low-intensive lifestyle education program (DiAlert) A randomized controlled trial.

    PubMed

    Heideman, Wieke H; de Wit, Maartje; Middelkoop, Barend J C; Nierkens, Vera; Stronks, Karien; Verhoeff, Arnoud P; Snoek, Frank J

    2015-04-01

    To test the efficacy of a low-intensive lifestyle education program (DiAlert) for overweight first degree relatives of type 2 diabetes patients aimed at reducing diabetes risk. Overweight first degree relatives of type 2 diabetes patients were randomly assigned to the DiAlert intervention (N=45) or control group who received leaflets (N=51). DiAlert consists of two group sessions and newsletters. Assessments were scheduled at baseline, three and nine months, with weight loss as primary outcome. Secondary outcomes included anthropometric, metabolic, behavioral and psychological measures. Comparisons were made over time and between groups. Both groups showed modest weight loss with no difference between randomization groups. However, after DiAlert significantly more participants lost 5% of their weight compared to controls (P=0.03). Significant improvement of waist circumference sustained after 9 months in the intervention group (intervention: -4.33cm, P<0.01/control: -1.25cm, P=0.08). Systolic blood pressure improved within the intervention group (intervention: -8.77mmHg, P<0.01/control: -1.03mmHg, P=0.60). No effect was observed for biomedical and psychosocial outcomes. Our low-intensive structured lifestyle education program helps overweight relatives to improve waist circumference and supports relevant weight loss. The family approach provides opportunities to reach and engage relatives at risk in diabetes prevention education. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Lung Transplant

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Carotid Endarterectomy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Pulmonary Embolism

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Pernicious Anemia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Catheter Ablation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. Immune Thrombocytopenia

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. Chest MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. Cardiac Rehabilitation

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. Cardiac MRI

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Oxygen Therapy

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Detecting alerts, notifying the physician, and offering action items: a comprehensive alerting system.

    PubMed Central

    Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.

    1996-01-01

    We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756

  4. Revealing the functional neuroanatomy of intrinsic alertness using fMRI: methodological peculiarities.

    PubMed

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies.

  5. Revealing the Functional Neuroanatomy of Intrinsic Alertness Using fMRI: Methodological Peculiarities

    PubMed Central

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that – as a methodological artifact – left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies. PMID:21984928

  6. ToxAlerts: a Web server of structural alerts for toxic chemicals and compounds with potential adverse reactions.

    PubMed

    Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V

    2012-08-27

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing.

  7. ToxAlerts: A Web Server of Structural Alerts for Toxic Chemicals and Compounds with Potential Adverse Reactions

    PubMed Central

    2012-01-01

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing. PMID:22876798

  8. Alert status of nuclear weapons

    NASA Astrophysics Data System (ADS)

    Kristensen, Hans M.

    2017-11-01

    Nuclear Alert Forces. Four nuclear-armed states deploy nuclear warheads on alert, ready to be used on relatively short notice: United States, Russia, France and Britain. Combined, the four countries deploy an estimated 1,869 nuclear alert warheads. Russia and the United States deploy 1,749 alert warheads combined, or 94% of all alert warheads. Despite some debate about possible need to increase readiness of nuclear forces (China, Pakistan), the five other nuclear-armed states (China, Pakistan, India, Israel and North Korea) are thought to store their warheads separate from launchers under normal circumstances. The overall number of alert warheads has remained relatively stable during the past five years.

  9. Automated External Defibrillator

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. Thrombocythemia and Thrombocytosis

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. von Willebrand Disease

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. Chest X-Ray

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. What Is Cardiomyopathy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Long QT Syndrome

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  15. Percutaneous Coronary Intervention

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. What is Hemophilia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. Thrombotic Thrombocytopenic Purpura

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. What Is Anemia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. Cardiac CT Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. Coronary Calcium Scan

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. Patent Ductus Arteriosus

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. What is Bronchoscopy?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  3. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    PubMed

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  4. Views of patients and professionals about electronic multicompartment medication devices: a qualitative study

    PubMed Central

    Hall, Jill; Bond, Christine; Kinnear, Moira; McKinstry, Brian

    2016-01-01

    Objectives To explore the perceived acceptability, advantages and disadvantages of electronic multicompartment medication devices. Design Qualitative study using 8 focus groups and 10 individual semistructured interviews. Recordings were transcribed and analysed thematically. Strategies were employed to ensure the findings were credible and trustworthy. Participants and setting Community pharmacists (n=11), general practitioners (n=9), community nurses (n=12) and social care managers (n=8) were recruited from the National Health Service (NHS) and local authority services. Patients (n=15) who were current conventional or electronic multicompartment medication device users or had medication adherence problems were recruited from community pharmacies. 3 informal carers participated. Results Electronic multicompartment medication devices which prompt the patient to take medication may be beneficial for selected individuals, particularly those with cognitive impairment, but who are not seriously impaired, provided they have a good level of dexterity. They may also assist individuals where it is important that medication is taken at fixed time intervals. These are likely to be people who are being supported to live alone. No single device suited everybody; smaller/lighter devices were preferred but their usefulness was limited by the small number/size of storage compartments. Removing medications was often challenging. Transportability was an important factor for patients and carers. A carer's alert if medication is not taken was problematic with multiple barriers to implementation and no consensus as to who should receive the alert. There was a lack of enthusiasm among professionals, particularly among pharmacists, due to concerns about responsibility and funding for devices as well as ensuring devices met regulatory standards for storage and labelling. Conclusions This study provides indicators of which patients might benefit from an electronic multicompartment medication device as well as the kinds of features to consider when matching a patient with a device. It also highlights other considerations for successful implementation including issues of responsibility, regulation and funding. PMID:27798025

  5. Alertness and cognitive control: Testing the early onset hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    Previous research has revealed a peculiar interaction between alertness and cognitive control in selective-attention tasks: Congruency effects are larger on alert trials (on which an alerting cue is presented briefly in advance of the imperative stimulus) than on no-alert trials, despite shorter response times (RTs) on alert trials. One explanation for this finding is the early onset hypothesis, which is based on the assumptions that increased alertness shortens stimulus-encoding time and that cognitive control involves gradually focusing attention during a trial. The author tested the hypothesis in 3 experiments by manipulating alertness and stimulus quality (which were intended to shorten and lengthen stimulus-encoding time, respectively) in an arrow-based flanker task involving congruent and incongruent stimuli. Replicating past findings, the alerting manipulation led to shorter RTs but larger congruency effects on alert trials than on no-alert trials. The stimulus-quality manipulation led to longer RTs and larger congruency effects for degraded stimuli than for intact stimuli. These results provide mixed support for the early onset hypothesis, but the author discusses how data and theory might be reconciled if stimulus quality affects stimulus-encoding time and the rate of evidence accumulation in the decision process. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Holter and Event Monitors

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  7. CHEMICAL SAFETY ALERTS-

    EPA Science Inventory

    Chemical Safety Alerts are short publications which explain specific hazards that have become evident through chemical accident investigation efforts. EPA has produced over a dozen Alerts to date. This year's Alert: Managing Chemical Reactivity Hazards

  8. What Is Heart Failure?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  9. What Is Bronchopulmonary Dysplasia?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  10. What Is Cardiac Catheterization?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  11. What Is a Ventilator?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  12. What Are Sleep Studies?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  13. What Are the Lungs?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  14. Piloted "Well Clear" Performance Evaluation of Detect-and-Avoid Systems with Suggestive Guidance

    NASA Technical Reports Server (NTRS)

    Mueller, Eric R.; Santiago, Confesor; Watza, Spencer

    2016-01-01

    This study evaluated the performance of four prototype unmanned aircraft detect-and-avoid (DAA) display configurations, each with different informational elements driven by alerting and guidance algorithms. Sixteen unmanned aircraft pilots flew each combination of the display configurations, with half being given zero DAA surveillance sensor uncertainty and the other half experiencing errors that were comparable, and in some cases slightly better than, errors that were measured in DAA system flight tests. The displays that showed intruder alert information in altitude and heading bands had significantly fewer losses of well clear compared with alternative displays that lacked that information. This difference was significant from a statistical and practical perspective: those losses that did occur lasted for shorter periods and did not penetrate as far into the geometric "separation cylinder" as those in the non-banded displays. A modest level of DAA surveillance sensor uncertainty did not affect the proportion of losses of well clear or their severity. It is recommended that DAA traffic displays implement a band-type display in order to improve the safety of UAS operations in the National Airspace System. Finally, this report provides pilot response time distributions for responding to DAA alerts.

  15. What Is Sudden Cardiac Arrest?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  16. Blood and Bone Marrow Transplant?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. What Is Respiratory Distress Syndrome?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  18. What Is a Heart Transplant?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  19. What is Broken Heart Syndrome

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  20. ARDS (Acute Respiratory Distress Syndrome)

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. What Are Bone Marrow Tests?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  2. Auditory alert systems with enhanced detectability

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  3. Physical properties and depth of cure of a new short fiber reinforced composite.

    PubMed

    Garoushi, Sufyan; Säilynoja, Eija; Vallittu, Pekka K; Lassila, Lippo

    2013-08-01

    To determine the physical properties and curing depth of a new short fiber composite intended for posterior large restorations (everX Posterior) in comparison to different commercial posterior composites (Alert, TetricEvoCeram Bulk Fill, Voco X-tra base, SDR, Venus Bulk Fill, SonicFill, Filtek Bulk Fill, Filtek Superme, and Filtek Z250). In addition, length of fiber fillers of composite XENIUS base compared to the previously introduced composite Alert has been measured. The following properties were examined according to ISO standard 4049: flexural strength, flexural modulus, fracture toughness, polymerization shrinkage and depth of cure. The mean and standard deviation were determined and all results were statistically analyzed with analysis of variance ANOVA (a=0.05). XENIUS base composite exhibited the highest fracture toughness (4.6MPam(1/2)) and flexural strength (124.3MPa) values and the lower shrinkage strain (0.17%) among the materials tested. Alert composite revealed the highest flexural modulus value (9.9GPa), which was not significantly different from XENIUS base composite (9.5GPa). Depth of cure of XENIUS base (4.6mm) was similar than those of bulk fill composites and higher than other hybrid composites. The length of fiber fillers in XENIUS base was longer (1.3-2mm) than in Alert (20-60μm). The new short fiber composite differed significantly in its physical properties compared to other materials tested. This suggests that the latter could be used in high-stress bearing areas. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  5. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  6. 49 CFR 229.140 - Alerters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerters shall provide an audio alarm upon expiration of the timing cycle interval. An alerter on a... indication to the operator at least five seconds prior to an audio alarm. The visual indication on an alerter...

  7. What Is a Total Artificial Heart?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  8. What Is a Ventricular Assist Device?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  9. An electronic trigger tool to optimise intravenous to oral antibiotic switch: a controlled, interrupted time series study.

    PubMed

    Berrevoets, Marvin A H; Pot, Johannes Hans L W; Houterman, Anne E; Dofferhoff, Anton Ton S M; Nabuurs-Franssen, Marrigje H; Fleuren, Hanneke W H A; Kullberg, Bart-Jan; Schouten, Jeroen A; Sprong, Tom

    2017-01-01

    Timely switch from intravenous (iv) antibiotics to oral therapy is a key component of antimicrobial stewardship programs in order to improve patient safety, promote early discharge and reduce costs. We have introduced a time-efficient and easily implementable intervention that relies on a computerized trigger tool, which identifies patients who are candidates for an iv to oral antibiotic switch. The intervention was introduced on all internal medicine wards in a teaching hospital. Patients were automatically identified by an electronic trigger tool when parenteral antibiotics were used for >48 h and clinical or pharmacological data did not preclude switch therapy. A weekly educational session was introduced to alert the physicians on the intervention wards. The intervention wards were compared with control wards, which included all other hospital wards. An interrupted time-series analysis was performed to compare the pre-intervention period with the post-intervention period using '% of i.v. prescriptions >72 h' and 'median duration of iv therapy per prescription' as outcomes. We performed a detailed prospective evaluation on a subset of 244 prescriptions to evaluate the efficacy and appropriateness of the intervention. The number of intravenous prescriptions longer than 72 h was reduced by 19% in the intervention group ( n  = 1519) ( p  < 0.01) and the median duration of iv antibiotics was reduced with 0.8 days ( p  = <0.05). Compared to the control group ( n  = 4366) the intervention was responsible for an additional decrease of 13% ( p  < 0.05) in prolonged prescriptions. The detailed prospective evaluation of a subgroup of patients showed that adherence to the electronic reminder was 72%. An electronic trigger tool combined with a weekly educational session was effective in reducing the duration of intravenous antimicrobial therapy.

  10. Development of an Electronic Medical Record Based Alert for Risk of HIV Treatment Failure in a Low-Resource Setting

    PubMed Central

    Puttkammer, Nancy; Zeliadt, Steven; Balan, Jean Gabriel; Baseman, Janet; Destiné, Rodney; Domerçant, Jean Wysler; France, Garilus; Hyppolite, Nathaelf; Pelletier, Valérie; Raphael, Nernst Atwood; Sherr, Kenneth; Yuhas, Krista; Barnhart, Scott

    2014-01-01

    Background The adoption of electronic medical record systems in resource-limited settings can help clinicians monitor patients' adherence to HIV antiretroviral therapy (ART) and identify patients at risk of future ART failure, allowing resources to be targeted to those most at risk. Methods Among adult patients enrolled on ART from 2005–2013 at two large, public-sector hospitals in Haiti, ART failure was assessed after 6–12 months on treatment, based on the World Health Organization's immunologic and clinical criteria. We identified models for predicting ART failure based on ART adherence measures and other patient characteristics. We assessed performance of candidate models using area under the receiver operating curve, and validated results using a randomly-split data sample. The selected prediction model was used to generate a risk score, and its ability to differentiate ART failure risk over a 42-month follow-up period was tested using stratified Kaplan Meier survival curves. Results Among 923 patients with CD4 results available during the period 6–12 months after ART initiation, 196 (21.2%) met ART failure criteria. The pharmacy-based proportion of days covered (PDC) measure performed best among five possible ART adherence measures at predicting ART failure. Average PDC during the first 6 months on ART was 79.0% among cases of ART failure and 88.6% among cases of non-failure (p<0.01). When additional information including sex, baseline CD4, and duration of enrollment in HIV care prior to ART initiation were added to PDC, the risk score differentiated between those who did and did not meet failure criteria over 42 months following ART initiation. Conclusions Pharmacy data are most useful for new ART adherence alerts within iSanté. Such alerts offer potential to help clinicians identify patients at high risk of ART failure so that they can be targeted with adherence support interventions, before ART failure occurs. PMID:25390044

  11. Development of an electronic medical record based alert for risk of HIV treatment failure in a low-resource setting.

    PubMed

    Puttkammer, Nancy; Zeliadt, Steven; Balan, Jean Gabriel; Baseman, Janet; Destiné, Rodney; Domerçant, Jean Wysler; France, Garilus; Hyppolite, Nathaelf; Pelletier, Valérie; Raphael, Nernst Atwood; Sherr, Kenneth; Yuhas, Krista; Barnhart, Scott

    2014-01-01

    The adoption of electronic medical record systems in resource-limited settings can help clinicians monitor patients' adherence to HIV antiretroviral therapy (ART) and identify patients at risk of future ART failure, allowing resources to be targeted to those most at risk. Among adult patients enrolled on ART from 2005-2013 at two large, public-sector hospitals in Haiti, ART failure was assessed after 6-12 months on treatment, based on the World Health Organization's immunologic and clinical criteria. We identified models for predicting ART failure based on ART adherence measures and other patient characteristics. We assessed performance of candidate models using area under the receiver operating curve, and validated results using a randomly-split data sample. The selected prediction model was used to generate a risk score, and its ability to differentiate ART failure risk over a 42-month follow-up period was tested using stratified Kaplan Meier survival curves. Among 923 patients with CD4 results available during the period 6-12 months after ART initiation, 196 (21.2%) met ART failure criteria. The pharmacy-based proportion of days covered (PDC) measure performed best among five possible ART adherence measures at predicting ART failure. Average PDC during the first 6 months on ART was 79.0% among cases of ART failure and 88.6% among cases of non-failure (p<0.01). When additional information including sex, baseline CD4, and duration of enrollment in HIV care prior to ART initiation were added to PDC, the risk score differentiated between those who did and did not meet failure criteria over 42 months following ART initiation. Pharmacy data are most useful for new ART adherence alerts within iSanté. Such alerts offer potential to help clinicians identify patients at high risk of ART failure so that they can be targeted with adherence support interventions, before ART failure occurs.

  12. NAS-Wide Fast-Time Simulation Study for Evaluating Performance of UAS Detect-and-Avoid Alerting and Guidance Systems

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Cone, Andrew Clayton; Thipphavong, David P.; Santiago, Confesor

    2016-01-01

    This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.

  13. Wireless clinical alerts for physiologic, laboratory and medication data.

    PubMed Central

    Shabot, M. M.; LoBue, M.; Chen, J.

    2000-01-01

    A fully interfaced clinical information system (CIS) contains physiologic, laboratory, blood gas, medication and other data that can be used as the information base for a comprehensive alerting system. Coupled with an event driven rules engine, a CIS can generate clinical alerts which may both prevent medical errors and assist caregivers in responding to critical events in a timely way. The authors have developed a clinical alerting system which delivers alerts and reminders to clinicians in real time via a alphanumeric display pagers. This paper will describe the system, the type and number of alerts generated, and the impact on clinical practice. A major issue remains in measuring the impact of wireless alerts on patient outcomes. PMID:11079992

  14. Alerts in mobile healthcare applications: requirements and pilot study.

    PubMed

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  15. Wearable PPG sensor based alertness scoring system.

    PubMed

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  16. Biomedical information @ the speed of light: implementing desktop access to publishers' resources at the Paterson Institute for Cancer Research.

    PubMed

    Glover, S W

    2001-06-01

    Shortly after midnight every Thursday morning, a list server in Massachusetts delivers an electronic table of contents message to the Kostoris Medical Library at the Paterson Institute for Cancer Research in Manchester, UK. The messageins details of the latest edition of the New England Journal of Medicine, complete with hyperlinks to the full text of the content online. Publishers' electronic current awareness services have been integrated into the dissemination process of the Library service to enhance the speed of communication and access to full text content. As a means of promoting electronic journal use, a system of e-mail delivery coupled with fast Internet access has allowed a migration from paper-based current awareness alerting to a seamless online product.

  17. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  18. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  19. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  20. Aspirin to Prevent a First Heart Attack or Stroke

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  1. Hot spots in a wired world: WHO surveillance of emerging and re-emerging infectious diseases.

    PubMed

    Heymann, D L; Rodier, G R

    2001-12-01

    The resurgence of the microbial threat, rooted in several recent trends, has increased the vulnerability of all nations to the risk of infectious diseases, whether newly emerging, well-established, or deliberately caused. Infectious disease intelligence, gleaned through sensitive surveillance, is the best defence. The epidemiological and laboratory techniques needed to detect, investigate, and contain a deliberate outbreak are the same as those used for natural outbreaks. In April 2000, WHO formalised an infrastructure (the Global Outbreak Alert and Response Network) for responding to the heightened need for early awareness of outbreaks and preparedness to respond. The Network, which unites 110 existing networks, is supported by several new mechanisms and a computer-driven tool for real time gathering of disease intelligence. The procedure for outbreak alert and response has four phases: systematic detection, outbreak verification, real time alerts, and rapid response. For response, the framework uses different strategies for combating known risks and unexpected events, and for improving both global and national preparedness. New forces at work in an electronically interconnected world are beginning to break down the traditional reluctance of countries to report outbreaks due to fear of the negative impact on trade and tourism. About 65% of the world's first news about infectious disease events now comes from informal sources, including press reports and the internet.

  2. Standardization of haematology critical results management in adults: an International Council for Standardization in Haematology, ICSH, survey and recommendations.

    PubMed

    Keng, T B; De La Salle, B; Bourner, G; Merino, A; Han, J-Y; Kawai, Y; Peng, M T; McCafferty, R

    2016-10-01

    These recommendations are intended to develop a consensus in the previously published papers as to which parameters and what values should be considered critical. A practical guide on the standardization of critical results management in haematology laboratories would be beneficial as part of good laboratory and clinical practice and for use by laboratory-accrediting agencies. A working group with members from Europe, America, Australasia and Asia was formed by International Council for Standardization in Haematology. A pattern of practice survey of 21 questions was distributed in 2014, and the data were collected electronically by Survey Monkey. The mode, or most commonly occurring value, was selected as the threshold for the upper and lower alert limits for critical results reporting. A total of 666 laboratories submitted data to this study and, of these, 499 submitted complete responses. Full blood count critical results alert thresholds, morphology findings that trigger critical result notification, critical results alert list, notification process and maintenance of critical results management protocol are described. This international survey provided a snapshot of the current practice worldwide and has identified the existence of considerable heterogeneity of critical results management. The recommendations in this study represent a consensus of good laboratory practice. They are intended to encourage the implementation of a standardized critical results management protocol in the laboratory. © 2016 John Wiley & Sons Ltd.

  3. Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)

    1997-01-01

    Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are given, and design considerations for alerting systems which alleviate the problem of non-conformance are provided.

  4. Validation of a personal fluid loss monitor.

    PubMed

    Wickwire, J; Bishop, P A; Green, J M; Richardson, M T; Lomax, R G; Casaru, C; Jones, E; Curtner-Smith, M

    2008-02-01

    Dehydration raises heat injury risk and reduces performance [ , , ]. The purpose was to validate the Hydra-Alert Jr (Acumen). The Hydra-Alert was tested in two exercise/clothing conditions. Participants wore it while wearing exercise clothing and exercising at a self-selected intensity (n = 8). Others wore the Hydra-Alert while wearing a ballistic-vest and performing an industrial-protocol (n = 8). For each condition, the Hydra-Alert was tested on two occasions (T1 and T2). The Hydra-Alert was tested against nude weight loss for both conditions. The Hydra-Alert had low test-retest reliability for both conditions (average absolute value of the error between Hydra-Alert outputs of T1 and T2 = 0.08 +/- 0.08 percentage points). With exercise-clothing, the Hydra-Alert evidenced low-moderate correlations between percent nude weight loss and Hydra-Alert output at 20 min (r = 0.59-T1, p = 0.13; r = 0.12-T2, p = 0.78), at 40 min (r = 0.93-T1, p = 0.001; r = 0.63-T2, p = 0.10), and at approximately 2 % weight loss (r = 0.21-T1 and T2, p = 0.61 and 0.62, respectively). The correlation at 40 min during T1 fell during T2 suggesting the Hydra-Alert was inconsistent. When wearing a ballistic-vest, the Hydra-Alert had poor validity (T1: r = - 0.29 [p = 0.48] for weight loss vs. monitor; T2: r = 0.11 [p = 0.80]). At the higher levels of dehydration ( approximately 2 %), the Hydra-Alert error was so high as to render its readings of little value. In some cases, the Hydra-Alert could lead to a false level of security if dehydrated. Therefore, the Hydra-Alert is of little use for those who want to measure their fluid loss while exercising in the heat.

  5. Real-time data acquisition and alerts may reduce reaction time and improve perfusionist performance during cardiopulmonary bypass.

    PubMed

    Beck, J R; Fung, K; Lopez, H; Mongero, L B; Argenziano, M

    2015-01-01

    Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations. © The Author(s) 2014.

  6. Nursing, Pharmacy, and Prescriber Knowledge and Perceptions of High-Alert Medications in a Large, Academic Medical Hospital

    PubMed Central

    Engels, Melanie J.

    2015-01-01

    Background: High-alert medications pose a greater risk of causing significant harm to patients if used in error. The Joint Commission requires that hospitals define institution-specific high-alert medications and implement processes to ensure safe medication use. Method: Nursing, pharmacy, and prescribers were asked to voluntarily complete a 34-question survey to assess their knowledge, experience, and perceptions regarding high-alert medications in an academic hospital. Results: The majority of respondents identified the organization’s high-alert medications, the consequences of an error involving a high-alert medication, and the reversal agent. Most of the risk-reduction strategies within the institution were viewed as being effective by respondents. Forty-five percent of the respondents utilized a high-alert medication in the previous 24 hours. Only 14.2% had experienced an error with a high-alert medication in the previous 12 months, with 46% being near misses. The survey found the 5 rights for medication administration were not being utilized consistently. Respondents indicated that work experience or hospital orientation is the preferred learning experience for high-alert medications. Conclusions: This study assessed all disciplines involved in the medication use process. Perceptions about high-alert medications differ between disciplines. Ongoing discipline-specific education is required to ensure that individuals accept accountability in the medication use process and to close knowledge gaps on high-alert medications and risk-reduction strategies. PMID:26446747

  7. Validation of an electronic surveillance system for acute lung injury

    PubMed Central

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D.; Gajic, Ognjen

    2009-01-01

    Objective Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Design Using a near-real time copy of the electronic medical records we developed and validated a custom ALI electronic alert (ALI “sniffer”) based on the European-American Consensus Conference Definition and compared its performance against provider derived documentation. Patients and setting Consecutive 3795 critically ill patients admitted to 9 multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution. Measurements and main results ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs 8.0 mL/kg predicted body weight, p<0.001). ALI “sniffer” demonstrated excellent sensitivity, 96% (95% CI 94 to 98) and moderate specificity, 89% (95% CI 88 to 90) with a positive predictive value ranging from 24% (95% CI 13 to 40) in the heart-lung transplant ICU to 64% (95% CI 55 to 71) in the medical ICU. Conclusions Computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research. PMID:19280175

  8. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  9. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  10. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  11. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  12. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  13. AmberAlert / DPS / DHSEM / AAB

    Science.gov Websites

    cooperative public service alert to aid in the safe recovery of abducted children. The Alaska AMBER Alert children to aid in their safe return. AMBER Alert Hotline: 866-AKAMBER - (866-252-6237) State of Alaska

  14. Analysis of Alerting System Failures in Commercial Aviation Accidents

    NASA Technical Reports Server (NTRS)

    Mumaw, Randall J.

    2017-01-01

    The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.

  15. A review of human factors principles for the design and implementation of medication safety alerts in clinical information systems.

    PubMed

    Phansalkar, Shobha; Edworthy, Judy; Hellier, Elizabeth; Seger, Diane L; Schedlbauer, Angela; Avery, Anthony J; Bates, David W

    2010-01-01

    The objective of this review is to describe the implementation of human factors principles for the design of alerts in clinical information systems. First, we conduct a review of alarm systems to identify human factors principles that are employed in the design and implementation of alerts. Second, we review the medical informatics literature to provide examples of the implementation of human factors principles in current clinical information systems using alerts to provide medication decision support. Last, we suggest actionable recommendations for delivering effective clinical decision support using alerts. A review of studies from the medical informatics literature suggests that many basic human factors principles are not followed, possibly contributing to the lack of acceptance of alerts in clinical information systems. We evaluate the limitations of current alerting philosophies and provide recommendations for improving acceptance of alerts by incorporating human factors principles in their design.

  16. Alerts Visualization and Clustering in Network-based Intrusion Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dr. Li; Gasior, Wade C; Dasireddy, Swetha

    2010-04-01

    Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administratormore » with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.« less

  17. Determining Inappropriate Medication Alerts from "Inaccurate Warning" Overrides in the Intensive Care Unit.

    PubMed

    Rehr, Christine A; Wong, Adrian; Seger, Diane L; Bates, David W

    2018-04-01

     This article aims to understand provider behavior around the use of the override reason "Inaccurate warning," specifically whether it is an effective way of identifying unhelpful medication alerts.  We analyzed alert overrides that occurred in the intensive care units (ICUs) of a major academic medical center between June and November 2016, focused on the following high-significance alert types: dose, drug-allergy alerts, and drug-drug interactions (DDI). Override appropriateness was analyzed by two independent reviewers using predetermined criteria.  A total of 268 of 26,501 ICU overrides (1.0%) used the reason "Inaccurate warning," with 93 of these overrides associated with our included alert types. Sixty-one of these overrides (66%) were identified to be appropriate. Twenty-one of 30 (70%) dose alert overrides were appropriate. Forty of 48 drug-allergy alert overrides (83%) were appropriate, for reasons ranging from prior tolerance ( n  = 30) to inaccurate ingredient matches ( n  = 5). None of the 15 DDI overrides were appropriate.  The "Inaccurate warning" reason was selectively used by a small proportion of providers and overrides using this reason identified important opportunities to reduce excess alerts. Potential opportunities include improved evaluation of dosing mechanisms based on patient characteristics, inclusion of institutional dosing protocols to alert logic, and evaluation of a patient's prior tolerance to a medication that they have a documented allergy for. This resource is not yet routinely used for alert tailoring at our institution but may prove to be a valuable resource to evaluate available alerts. Schattauer GmbH Stuttgart.

  18. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were asked to identify the alert as quickly and as accurately as possible. Reaction time and accuracy were measured. Participants identified speech alerts significantly faster than tone alerts. The HERA study investigated the performance of participants in a flight-like environment. Participants were instructed to complete items on a task list and respond to C&W alerts as they occurred. Reaction time and accuracy were measured to determine if the benefits of speech alarms are still present in an applied setting.

  19. For whom the bell tolls: Silver Alerts raise concerns regarding individual rights and governmental interests.

    PubMed

    Wasser, Tobias D; Fox, Patrick K

    2013-01-01

    The Silver Alert system was initially created to help protect missing persons who have cognitive impairments, particularly the elderly. The Silver Alert is modeled after the Amber Alert, created to help locate and safeguard missing children. Unlike the Amber Alert, however, in most states the Silver Alert applies to the elderly, adults with a mental impairment, or both, depending on the state. The goal of the Silver Alert system is the quick dissemination of information about missing persons to law enforcement personnel as well as to the general public. Previously, states notified law enforcement personnel of missing persons through teletype to other public safety jurisdictions to enlist their assistance in the retrieval of the missing person. Silver Alert programs substantially expand the notification to include the general public, who receive information through radio and television broadcasts as well as highway billboards. The programs serve a legitimate governmental interest by protecting a vulnerable population from possible harm. Yet, the implementation of these alerts can have unintended consequences, including the possible violation of an individual's right to privacy. Such consequences require careful consideration.

  20. Evaluation of Helmet Mounted Display Alerting Symbology

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe; Rutkowski, Michael (Technical Monitor)

    2000-01-01

    Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.

  1. 47 CFR 10.240 - Notification to new subscribers of non-participation in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-participation in CMAS. 10.240 Section 10.240 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.240... EMERGENCY ALERTS (Commercial Mobile Alert Service) [[CMS provider

  2. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  3. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  4. 47 CFR 10.410 - Prioritization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message... required to transmit Imminent Threat Alerts and AMBER Alerts on a first in-first out (FIFO) basis. ...

  5. Commercial Motor Vehicle Driver Fatigue And Alertness Study Executive Summary

    DOT National Transportation Integrated Search

    1996-11-01

    THE DRIVER FATIGUE AND ALERTNESS STUDY (DFAS) WAS THE LARGEST AND MOST COMPREHENSIVE OVER-THE-ROAD STUDY EVER CONDUCTED ON DRIVER FATIGUE AND ALERTNESS IN NORTH AMERICA. IT PROVIDES EXTENSIVE INFORMATION ON THE ALERTNESS, DRIVING PERFORMANCE, AND PHY...

  6. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  7. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  8. 47 CFR 11.56 - Obligation to process CAP-formatted EAS messages.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), and Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1...) “Common Alerting Protocol, v. 1.2 USA Integrated Public Alert and Warning System Profile Version 1.0” (Oct...

  9. Central Fetal Monitoring With and Without Computer Analysis: A Randomized Controlled Trial.

    PubMed

    Nunes, Inês; Ayres-de-Campos, Diogo; Ugwumadu, Austin; Amin, Pina; Banfield, Philip; Nicoll, Antony; Cunningham, Simon; Sousa, Paulo; Costa-Santos, Cristina; Bernardes, João

    2017-01-01

    To evaluate whether intrapartum fetal monitoring with computer analysis and real-time alerts decreases the rate of newborn metabolic acidosis or obstetric intervention when compared with visual analysis. A randomized clinical trial carried out in five hospitals in the United Kingdom evaluated women with singleton, vertex fetuses of 36 weeks of gestation or greater during labor. Continuous central fetal monitoring by computer analysis and online alerts (experimental arm) was compared with visual analysis (control arm). Fetal blood sampling and electrocardiographic ST waveform analysis were available in both arms. The primary outcome was incidence of newborn metabolic acidosis (pH less than 7.05 and base deficit greater than 12 mmol/L). Prespecified secondary outcomes included operative delivery, use of fetal blood sampling, low 5-minute Apgar score, neonatal intensive care unit admission, hypoxic-ischemic encephalopathy, and perinatal death. A sample size of 3,660 per group (N=7,320) was planned to be able to detect a reduction in the rate of metabolic acidosis from 2.8% to 1.8% (two-tailed α of 0.05 with 80% power). From August 2011 through July 2014, 32,306 women were assessed for eligibility and 7,730 were randomized: 3,961 to computer analysis and online alerts, and 3,769 to visual analysis. Baseline characteristics were similar in both groups. Metabolic acidosis occurred in 16 participants (0.40%) in the experimental arm and 22 participants (0.58%) in the control arm (relative risk 0.69 [0.36-1.31]). No statistically significant differences were found in the incidence of secondary outcomes. Compared with visual analysis, computer analysis of fetal monitoring signals with real-time alerts did not significantly reduce the rate of metabolic acidosis or obstetric intervention. A lower-than-expected rate of newborn metabolic acidosis was observed in both arms of the trial. ISRCTN Registry, http://www.isrctn.com, ISRCTN42314164.

  10. Weak central coherence in weight-restored adolescent anorexia nervosa: Characteristics and remediation.

    PubMed

    Weinbach, Noam; Perry, Amit; Sher, Helene; Lock, James D; Henik, Avishai

    2017-08-01

    Weak central coherence (WCC) refers to a bias towards processing details (local processing) at the expense of paying attention to the bigger picture (global processing). Multiple studies reported WCC in adults with anorexia nervosa (AN). Evidence for WCC in adolescents with AN has been inconsistent. The current study characterizes WCC in weight-restored adolescents with AN (WR-AN) using a direct measure of WCC, and examines whether WCC can be remediated by increasing alertness level-a manipulation that was found useful in enhancing global processing in healthy individuals and clinical populations. 40 adolescents (18 WR-AN and 22 healthy adolescents) performed a global/local processing task (Navon task). Auditory alerting cues that elevate alertness level were integrated into the task. Both groups processed global information faster than local information. However, compared with controls, adolescents with WR-AN were better at ignoring an irrelevant bigger picture while attending to details (smaller global interference) and had greater difficulty ignoring irrelevant details while attending to the bigger picture (larger local interference). These differences were attenuated when adolescents with WR-AN were under a state of high alertness. Additionally, the local interference effect was positively correlated with three independent self-report questionnaires assessing eating disorders symptomatology. This study suggests that abnormal interference by irrelevant global and local information is a central characteristic of WCC in adolescents with WR-AN that cannot be accounted for by enduring illness or malnourishment. Additionally, this study demonstrates that WCC can be temporarily remediated by encouraging a state of high alertness. © 2017 Wiley Periodicals, Inc.

  11. [Circadian rhythm : Influence on Epworth Sleepiness Scale score].

    PubMed

    Herzog, M; Bedorf, A; Rohrmeier, C; Kühnel, T; Herzog, B; Bremert, T; Plontke, S; Plößl, S

    2017-02-01

    The Epworth Sleepiness Scale (ESS) is frequently used to determine daytime sleepiness in patients with sleep-disordered breathing. It is still unclear whether different levels of alertness induced by the circadian rhythm influence ESS score. The aim of this study is to investigate the influence of circadian rhythm-dependent alertness on ESS performance. In a monocentric prospective noninterventional observation study, 97 patients with suspected sleep-disordered breathing were investigated with respect to daytime sleepiness in temporal relationship to polysomnographic examination and treatment. The Karolinska Sleepiness Scale (KSS) and the Stanford Sleepiness Scale (SSS) served as references for the detection of present sleepiness at three different measurement times (morning, noon, evening), prior to and following a diagnostic polysomnography night as well as after a continuous positive airway pressure (CPAP) titration night (9 measurements in total). The KSS, SSS, and ESS were performed at these times in a randomized order. The KSS and SSS scores revealed a circadian rhythm-dependent curve with increased sleepiness at noon and in the evening. Following a diagnostic polysomnography night, the scores were increased compared to the measurements prior to the night. After the CPAP titration night, sleepiness in the morning was reduced. KSS and SSS reflect the changes in alertness induced by the circadian rhythm. The ESS score war neither altered by the intra-daily nor by the inter-daily changes in the level of alertness. According to the present data, the ESS serves as a reliable instrument to detect the level of daytime sleepiness independently of the circadian rhythm-dependent level of alertness.

  12. An Investigation of Drug-Drug Interaction Alert Overrides at a Pediatric Hospital.

    PubMed

    Humphrey, Kate; Jorina, Maria; Harper, Marvin; Dodson, Brenda; Kim, Seung-Yeon; Ozonoff, Al

    2018-05-01

    Drug-drug interactions (DDIs) can result in patient harm. DDI alerts are intended to help prevent harm; when the majority of alerts presented to providers are being overridden, their value is diminished. Our objective was to evaluate the overall rates of DDI alert overrides and how rates varied by specialty, clinician type, and patient complexity. A retrospective study of DDI alert overrides that occurred during 2012 and 2013 within the inpatient setting described at the medication-, hospital-, provider-, and patient encounter-specific levels was performed at an urban, quaternary-care, pediatric hospital. There were >41 000 DDI alerts presented to clinicians; ∼90% were overridden. The 5 DDI pairs that were most frequently presented and overridden included the following: potassium chloride-spironolactone, methadone-ondansetron, ketorolac-ibuprofen, cyclosporine-fluconazole, and potassium chloride-enalapril, each with an alert override rate of ≥0.89. Override rates across provider groups ranged between 0.84 and 0.97. In general, patients with high complexity had a higher frequency of alert overrides, but the rates of alert overrides for each DDI pairing did not differ significantly. High rates of DDI alert overrides occur across medications, provider groups, and patient encounters. Methods to decrease DDI alerts which are likely to be overridden exist, but it is also clear that more robust and intelligent tools are needed. Characteristics exist at the medication, hospital, provider, and patient levels that can be used to help specialize and enhance information transmission. Copyright © 2018 by the American Academy of Pediatrics.

  13. Evaluation of email alerts in practice: Part 2. Validation of the information assessment method.

    PubMed

    Pluye, Pierre; Grad, Roland M; Johnson-Lafleur, Janique; Bambrick, Tara; Burnand, Bernard; Mercer, Jay; Marlow, Bernard; Campbell, Craig

    2010-12-01

    The information assessment method (IAM) permits health professionals to systematically document the relevance, cognitive impact, use and health outcomes of information objects delivered by or retrieved from electronic knowledge resources. The companion review paper (Part 1) critically examined the literature, and proposed a 'Push-Pull-Acquisition-Cognition-Application' evaluation framework, which is operationalized by IAM. The purpose of the present paper (Part 2) is to examine the content validity of the IAM cognitive checklist when linked to email alerts. A qualitative component of a mixed methods study was conducted with 46 doctors reading and rating research-based synopses sent on email. The unit of analysis was a doctor's explanation of a rating of one item regarding one synopsis. Interviews with participants provided 253 units that were analysed to assess concordance with item definitions. The content relevance of seven items was supported. For three items, revisions were needed. Interviews suggested one new item. This study has yielded a 2008 version of IAM. © 2010 Blackwell Publishing Ltd.

  14. Hazard evaluation and operational cockpit display of ground-measured windshear data

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John, Jr.

    1993-01-01

    Low-altitude windshear is the leading weather-related cause of fatal aviation accidents in the U.S. Since 1964, there have been 26 accidents attributed to windshear resulting in over 500 fatalities. Low-altitude windshear can take several forms, including macroscopic forms such as cold-warm gustfronts down to the small, intense downdrafts known as microbursts. Microbursts are particularly dangerous and difficult to detect due to their small size, short duration, and occurrence under both heavy precipitation and virtually dry conditions. For these reasons, the real-time detection of windshear hazards is a very active field of research. Also, the advent of digital ground-to-air datalinks and electronic flight instrumentation opens up many options for implementation of windshear alerts in the terminal area environment. Study is required to determine the best content, format, timing, and cockpit presentation of windshear alerts in the modern ATC environment to best inform the flight crew without significantly increasing crew workload.

  15. Adaptation of the Fresenius PD+ Cycler for a hearing-impaired patient.

    PubMed

    Kushner, A

    2000-01-01

    Continuous cycling peritoneal dialysis (CCPD) uses a cycler to perform dialysis exchanges and requires the patient to respond to an audible alarm signifying an interruption in the therapy. Consequently, an unassisted hearing-impaired patient could not use the system. By converting the standard alarm to a vibrating signal, the cycler was successfully adapted to accommodate the special needs of our hearing-impaired patient. The items required for the modification were the Sonic Alert Wake Up Alarm (Model SA-WA300: Sonic Alert, Troy, MI, U.S.A.) and the Sonic Alert Super Shaker Bed Vibrator (Model SA-SS120V: Sonic Alert). The patient can place the vibrator under either the pillow or the mattress. When the cycler alarm is activated, vibration wakens the patient. The equipment was purchased from Harris Communications (Eden Prairie, MN, U.S.A.) through a referral by the Easter Seal Society. Three days were needed to complete training compared to an average of one or two days for patients previously trained for continuous ambulatory peritoneal dialysis (CAPD). The patient remained on cycler therapy for approximately four months when the unrelated development of an abdominal hernia required termination of peritoneal dialysis and subsequent transfer to hemodialysis. In conclusion, a modified cycler can provide a safe and efficient renal replacement therapy option for a hearing-impaired patient.

  16. Crew factors in flight operations 9: Effects of planned cockpit rest on crew performance and alertness in long-haul operations

    NASA Technical Reports Server (NTRS)

    Rosekind, Mark R.; Graeber, R. Curtis; Dinges, David F.; Connell, Linda J.; Rountree, Michael S.; Spinweber, Cheryl L.; Gillen, Kelly A.

    1994-01-01

    This study examined the effectiveness of a planned cockpit rest period to improve alertness and performance in long-haul flight operations. The Rest Group (12 crew members) was allowed a planned 40 minute rest period during the low workload, cruise portion of the flight, while the No-Rest Group (9 crew members) had a 40 minute planned control period when they maintained usual flight activities. Measures used in the study included continuous ambulatory recordings of brain wave and eye movement activity, a reaction time/vigilance task, a wrist activity monitor, in-flight fatigue and alertness ratings, a daily log for noting sleep periods, meals, exercise, flight and duty periods, and the NASA Background Questionnaire. The Rest Group pilots slept on 93 percent of the opportunities, falling asleep in 5.6 minutes and sleeping for 25.8 minutes. This nap was associated with improved physiological alertness and performance compared to the No-Rest Group. The benefits of the nap were observed through the critical descent and landing phases of flight. The nap did not affect layover sleep or the cumulative sleep debt. The nap procedures were implemented with minimal disruption to usual flight operations and there were no reported or identified concerns regarding safety.

  17. AN ELECTRONIC PRESCRIPTION ALERTING SYSTEM-IMPROVING THE DISCHARGE MEDICINES PROCESS.

    PubMed

    Bevan, Amanda; Patel, Niesh

    2016-09-01

    Whilst the prescribing of both in-patient and discharge medicines is electronic, there was no automatic notification to clinical pharmacists when a discharge prescription was ready to be screened. The notification required a member of medical or nursing staff to bleep their pharmacist informing them of a prescription's availability. This manual process led to a delay in pharmacist screening which impacted on discharge. Prescriptions designated for pre-packed or patient's own medicine use were not seen at all by a clinical pharmacist. The initial intention was to develop a text messaging service; however this was not possible due to significant cost implications and its inflexibility. To decrease the time to clinical pharmacist screening for children's discharge prescriptions. A clinical pharmacist prescription alerting system was designed and implemented. The hospital's eDischarge Summaries are created and stored in the Trust's EPR database. A database query is executed that examines documents that have been signed by a prescriber which contain drug orders. The query runs every 15 minutes, Monday to Friday from 0800-2000. The database query exports a HTML data extract which is then packaged and sent using Exchange.Email was preferred as users access hospital WiFi, only receiving notifications on those laptops or smartphones connected to the Trust's email application. The HTML is embedded within the email body. The email is sent to named individuals within a given distribution list. The function is scalable to support all areas using Trust eDischarge Summaries.The system was introduced in April 2015. Data from before (June 2014-January 2015) and after (June 2015) implementation was compared. Prior to the introduction of an electronic alerting system the average time from a prescriber signing a prescription to clinical pharmacist screening was 93 minutes. Three months after starting the new system this time has reduced to 62 minutes, a reduction of 31 minutes or 33%. During the same time period, the number of discharge prescriptions screened by pharmacists rose from 172 to 218, an increase in workload of 26%.It has been possible to intervene on prescriptions containing errors which the clinical pharmacists would not previously have screened. The use of an electronic messaging system has met its primary aim to decrease the time delay from signing to pharmacist screening it has also increased pharmacist efficiency as evidenced by the increased workload.One limitation of this system is that it requires a regular e-mail check, for available prescriptions. The report runs every 15 minutes, an email is only sent if a prescription is found.The notification of all discharge prescriptions containing medicines has led to the identification of errors which have required intervention, in those prescriptions that a pharmacist would not have previously seen. These interventions have been for children who have received pre-packed antibiotics directly from the wards or for those where we have provided one-stop dispensing.It is hoped to role out this system across other areas of the organisation which should also enjoy this significant improvement in discharge prescription turnaround. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  19. 77 FR 41331 - Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...

  20. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

Top