Okon, Uduak Akpan; Utuk, Ikponoabasi Ibanga
2016-01-01
Infertility issues have been linked to the effect of oxidative reaction in the reproductive system. This study evaluated the effect of ascorbic acid, on fertility parameters of male albino Wistar rats was studied. Eighteen albino Wistar rats weighed between 178 g and 241 g were used, randomly assigned into three groups. Group 1 was the control group; oral gavaged 5 ml of distilled water; Groups 2 and 3 were administered medium dose (250 mg/kg) and high dose of ascorbic acid (400 mg/kg), respectively; twice daily for 21 days. Blood samples were obtained by cardiac puncture, and blood serum was obtained for hormonal assay, and the testes were harvested for sperm analysis. Follicle stimulating hormone levels significantly increased in the high-dose group as compared to both the control and medium dose groups. Luteinizing hormone levels in the medium dose group decreased significantly as compared to the control group. Testosterone significantly increased in both the medium- and high-dose groups as compared to the control group. Sperm motility increased significantly in the high-dose group as compared to both control and medium-dose groups. Percentage sperm concentration decreased significantly in the medium-dose group when compared to the control and increased significantly in the high-dose group as compared to the medium-dose group. For percentage normal morphology, there was a dose-dependent increase in the test groups when compared to control group. These results are indicative of a positive influence of ascorbic acid on male fertility modulators and may therefore, serve as a potential adjuvant treatment for male infertility cases.
Chen, Yingying; Liu, Peng; Chen, Xia; Li, Yanan; Zhang, Fengmei; Wang, Yangang
2018-05-01
There is a lack of research on the effect of low dose of angiotensin receptor blockers combined with spironolactone, and the effect of high dose of angiotensin receptor blockers alone on the urinary albumin excretion rate (UAER) in elderly patients with early type 2 diabetic nephropathy (DN). We conducted a prospective, randomized, open-label, parallel-controlled study that included 244 elderly patients with early DN and mild-to-moderate essential hypertension. Patients were randomly divided into 4 groups: low-dose irbesartan (group A), high-dose irbesartan (group B), low-dose irbesartan combined with spironolactone (group C) and high-dose irbesartan combined with spironolactone (group D). Changes in UAER, serum potassium and blood pressure were compared. There were no statistical differences in the baseline characteristics among groups. Furthermore, no significant difference in blood pressure before and after treatment was found among different groups. After 72-week treatment, UAER in group D was lower compared to group A and B (P < 0.05). Meanwhile, compared with group B, UAER in group C decreased significantly (P < 0.05). Additionally, significantly higher serum potassium was found in group D compared to other groups (P < 0.05). Also, group D had the highest count of patients who withdrew from the study due to hyperkalemia compared to other groups (P < 0.05). Our results indicate high-dose irbesartan combined with spironolactone may be more efficient in reducing UAER in elderly patients with early DN, but this treatment could cause hyperkalemia. Low-dose irbesartan combined with spironolactone was shown to be safer and more effective in decreasing UAER compared to high-dose irbesartan. Copyright © 2018 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Mohamed, Hanaa Mahmoud; Mohamed, Manal Abdul-Hamid
2015-01-01
The present study aims of to investigate the effects of low and high doses of nandrolone decanoate (ND) on histopathology and apoptosis of the spermatogenic cells as well as lipid peroxidation, antioxidant enzyme activities, sperm abnormality and DNA fragmentation. Eighteen animals were divided into three groups each group contain six animals. The rats were divided into three groups as following: Group 1 was administered saline (control). Group 2, received nandrolone decanoate (3 mg/kg/weekly) (low dose) with intramuscular injection. Group 3, received intramuscular injection dose of nandrolone decanoate (10 mg/kg/weekly) (high dose). After 8 weeks, caspase-3 assay was used to determine the apoptotic cells. The sperm parameters, lipid peroxidation, antioxidant enzyme activities and testosterone concentration were also investigated in the experimental groups of both low and high dose compared to the control groups. Treated group with high dose showed degenerated germinal epithelial cells sloughed in the lumina of seminiferous tubules, where almost seminiferous tubules were devoid of spermatids and spermatozoa compared to control and group treated with low dose. Also, a significant increase of lipid peroxidation levels and heat shock proteins was observed in two groups administrated with two different doses of ND while, antioxidant enzyme activities, and testosterone concentration was significantly decreased in two treated group when compared with control. Administration of ND at high and low doses leads to deteriorated sperm parameters, DNA fragmentation and testicular apoptosis. In conclusion, the administration ND at high doses more effective on lipid peroxidation, antioxidant enzyme activities, sperm abnormality, histopathology, apoptotic and DNA changes compared to low dose group and to control group. Published by Elsevier GmbH.
High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.
Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John
2007-03-01
The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.
Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina; Martinez-Lopez, Joaquin; Knop, Stefan; Yu, Xin; Hong, Kevin; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Miguel, Jesus San
2016-01-01
Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethasone; n=93, high-dose dexamethasone). Median progression-free survival was similar for both subgroups and favored pomalidomide + low-dose dexamethasone versus high-dose dexamethasone: 4.0 versus 1.9 months in the group with baseline creatinine clearance ≥ 30 − < 60 mL/min (P<0.001) and 4.0 versus 2.0 months in the group with baseline creatinine clearance ≥ 60 mL/min (P<0.001). Median overall survival for pomalidomide + low-dose dexamethasone versus high-dose dexamethasone was 10.4 versus 4.9 months (P=0.030) and 15.5 versus 9.2 months (P=0.133), respectively. Improved renal function, defined as an increase in creatinine clearance from < 60 to ≥ 60 mL/min, was similar in pomalidomide + low-dose dexamethasone and high-dose dexamethasone patients (42% and 47%, respectively). Improvement in progression-free and overall survival in these patients was comparable with that in patients without renal impairment. There was no increase in discontinuations of therapy, dose modifications, and adverse events in patients with moderate renal impairment. Pomalidomide at a starting dose of 4 mg + low-dose dexamethasone is well tolerated in patients with refractory or relapsed and refractory multiple myeloma, and of comparable efficacy if moderate renal impairment is present. This trial was registered with clinicaltrials.gov identifier 01311687 and EudraCT identifier 2010-019820-30. PMID:27081177
Thai, Wai-ee; Wai, Bryan; Lin, Kaity; Cheng, Teresa; Heist, E. Kevin; Hoffmann, Udo; Singh, Jagmeet; Truong, Quynh A.
2012-01-01
Background Efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual source CT (DSCT) protocol, we aim to determine the radiation dose and image quality (IQ) in patients undergoing pulmonary vein (PV) imaging. Methods and Results In 94 patients (61±9 years, 71% male) who underwent 128-slice DSCT (pitch 3.4), radiation dose and IQ were assessed and compared between 69 patients in sinus rhythm (SR) and 25 in atrial fibrillation (AF). Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high-pitch. In a subset of 18 patients with prior magnetic resonance imaging (MRI) for PV assessment, PV anatomy and scan duration were compared to high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 [1.3, 1.9] mSv, with no difference between SR and AF (1.4 vs 1.5 mSv, p=0.22). No high-pitch CT scans were non-diagnostic or had poor IQ. Radiation dose was reduced with high-pitch (1.6 mSv) compared to standard protocols (19.3 mSv, p<0.0001). This radiation dose reduction was seen with SR (1.5 vs 16.7 mSv, p<0.0001) but was more profound with AF (1.9 vs 27.7 mSv, p=0.039). There was excellent agreement of PV anatomy (kappa 0.84, p<0.0001), and a shorter CT scan duration (6 minutes) compared to MRI (41 minutes, p<0.0001). Conclusions Using a high-pitch DSCT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent IQ in patients with SR or AF. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy. PMID:22586259
Youssef, Mohamed Abdel-Fattah; van Wely, Madelon; Mochtar, Monique; Fouda, Usama Mohamed; Eldaly, Ashraf; El Abidin, Eman Zein; Elhalwagy, Ahmed; Mageed Abdallah, Ahmed Abdel; Zaki, Sherif Sameh; Abdel Ghafar, Mohamed Sayed; Mohesen, Mohamed Nagi; van der Veen, Fulco
2018-02-01
To evaluate the effectiveness of low doses of gonadotropins and gonadotropins combined with oral compounds compared with high doses of gonadotropins in ovarian stimulation regimens in terms of ongoing pregnancy per fresh IVF attempt in women with poor ovarian reserve undergoing IVF/intracytoplasmic sperm injection (ICSI) treatment. A systematic review and meta-analysis of randomized controlled studies that evaluate the effectiveness of low dosing of gonadotropins alone or combined with oral compounds compared with high doses of gonadotropins in women with poor ovarian reserve undergoing IVF/ICSI treatment. Not applicable. Subfertile women with poor ovarian reserve undergoing IVF/ICSI treatment. We searched the PubMed, EMBASE, Web of Science, the Cochrane Library, and the Clinical Trials Registry using medical subject headings and free text terms up to June 2016, without language or year restrictions. We included randomized controlled studies (RCTs) enrolling subfertile women with poor ovarian reserve undergoing IVF/ICSI treatment and comparing low doses of gonadotropins and gonadotropins combined with oral compounds versus high doses of gonadotropins. We assessed the risk of bias using the criteria recommended by the Cochrane Collaboration. We pooled the results by meta-analysis using the fixed and random effects model. The primary outcome was ongoing pregnancy rate (PR) per woman randomized. We retrieved 787 records. Fourteen RCTs (N = 2,104 women) were included in the analysis. Five studies (N = 717 women) compared low doses of gonadotropins versus high doses of gonadotropins. There was no evidence of a difference in ongoing PR (2 RCTs: risk rate 0.98, 95% confidence interval 0.62-1.57, I 2 = 0). Nine studies (N = 1,387 women) compared ovarian stimulation using gonadotropins combined with the oral compounds letrozole (n = 6) or clomiphene citrate (CC) (n = 3) versus high doses of gonadotropins. There was no evidence of a difference in ongoing PR (3 RCTs: risk rate 0.90, 95% confidence interval 0.63-1.27, I 2 = 0). We found no evidence of a difference in pregnancy outcomes between low doses of gonadotropins and gonadotropins combined with oral compounds compared with high doses of gonadotropins in ovarian stimulation regimens. Whether low doses of gonadotropins or gonadotropins combined with oral compounds is to be preferred is unknown, as they have never been compared head to head. A health economic analysis to test the hypothesis that an ovarian stimulation with low dosing is more cost-effective than high doses of gonadotropins is needed. CRD42016041301. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Comparative trial of low- and high-dose zonisamide as monotherapy for childhood epilepsy.
Eun, So-Hee; Kim, Heung Dong; Eun, Baik-Lin; Lee, In Kyu; Chung, Hee Jung; Kim, Joon Sik; Kang, Hoon-Chul; Lee, Young-Mock; Suh, Eun Sook; Kim, Dong Wook; Eom, Soyong; Lee, Joon Soo; Moon, Han Ku
2011-09-01
To evaluate the effectiveness of zonisamide (ZNS) as monotherapy in children with newly diagnosed epilepsy. This randomized, multicenter trial included a 2-4-week titration and a 24-week maintenance phase after randomization to low-(3-4 mg/kg/day) or high-(6-8 mg/kg/day) dose groups as target maintenance dosages. The primary outcome measure was the seizure-free rate over 6 months, while a secondary measure was the change in cognition and behavior from screening to the end of the maintenance phase. Out of 125 patients enrolled, 90 (49 low-dose and 41 high-dose) completed the study. Forty-one patients (63.1%) in the low-dose group and 34(57.6%) in the high-dose group achieved 6 months' freedom from seizures (p=0.66). After treatment, the picture arrangement subtest improved in the low-dose group (p=0.047) while the vocabulary subtest worsened in the high-dose group (p=0.020). Comparing between the two groups, the vocabulary subtest in the high-dose group was significantly worse than that in the low-dose group (p=0.002). Social competence, somatic complaints, depression/anxiety and delinquent and aggressive behavior in the low-dose group were significantly improved (p<0.05). Moreover, total social competence, somatic complaints, delinquent behavior, externalizing, and total behavior problems were significantly more improved in the low-dose group than the high-dose group (p<0.05). ZNS is an effective monotherapy for newly diagnosed childhood epilepsy. Lower doses of ZNS have a similar efficacy and more beneficial neurocognitive effects compared to higher doses. When prescribing higher doses of ZNS, one must be aware of the possible manifestation of problems associated with language development, such as those affecting vocabulary acquisition. Copyright © 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Estcourt, Lise J; Stanworth, Simon; Doree, Carolyn; Trivella, Marialena; Hopewell, Sally; Blanco, Patricia; Murphy, Michael F
2015-01-01
Background Platelet transfusions are used in modern clinical practice to prevent and treat bleeding in people who are thrombocytopenic due to bone marrow failure. Although considerable advances have been made in platelet transfusion therapy in the last 40 years, some areas continue to provoke debate, especially concerning the use of prophylactic platelet transfusions for the prevention of thrombocytopenic bleeding. This is an update of a Cochrane review first published in 2004, and updated in 2012 that addressed four separate questions: prophylactic versus therapeutic-only platelet transfusion policy; prophylactic platelet transfusion threshold; prophylactic platelet transfusion dose; and platelet transfusions compared to alternative treatments. This review has now been split into four smaller reviews; this review compares different platelet transfusion doses. Objectives To determine whether different doses of prophylactic platelet transfusions (platelet transfusions given to prevent bleeding) affect their efficacy and safety in preventing bleeding in people with haematological disorders undergoing myelosuppressive chemotherapy with or without haematopoietic stem cell transplantation (HSCT). Search methods We searched for randomised controlled trials in the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Library 2015, Issue 6), MEDLINE (from 1946), Embase (from 1974), CINAHL (from 1937), the Transfusion Evidence Library (from 1950), and ongoing trial databases to 23 July 2015. Selection criteria Randomised controlled trials involving transfusions of platelet concentrates, prepared either from individual units of whole blood or by apheresis, and given to prevent bleeding in people with malignant haematological disorders or undergoing HSCT that compared different platelet component doses (low dose 1.1 × 1011/m2 ± 25%, standard dose 2.2 × 1011/m2 ± 25%, high dose 4.4 × 1011/m2 ± 25%). Data collection and analysis We used the standard methodological procedures expected by The Cochrane Collaboration. Main results We included seven trials (1814 participants) in this review; six were conducted during one course of treatment (chemotherapy or HSCT). Overall the methodological quality of studies was low to moderate across different outcomes according to GRADE methodology. None of the included studies were at low risk of bias in every domain, and all the included studies had some threats to validity. Five studies reported the number of participants with at least one clinically significant bleeding episode within 30 days from the start of the study. There was no difference in the number of participants with a clinically significant bleeding episode between the low-dose and standard-dose groups (four studies; 1170 participants; risk ratio (RR) 1.04, 95% confidence interval (CI) 0.95 to 1.13; moderate-quality evidence); low-dose and high-dose groups (one study; 849 participants; RR 1.02, 95% CI 0.93 to 1.11; moderate-quality evidence); or high-dose and standard-dose groups (two studies; 951 participants; RR 1.02, 95% CI 0.93 to 1.11; moderate-quality evidence). Three studies reported the number of days with a clinically significant bleeding event per participant. There was no difference in the number of days of bleeding per participant between the low-dose and standard-dose groups (two studies; 230 participants; mean difference −0.17, 95% CI −0.51 to 0.17; low quality evidence). One study (855 participants) showed no difference in the number of days of bleeding per participant between high-dose and standard-dose groups, or between low-dose and high-dose groups (849 participants). Three studies reported the number of participants with severe or life-threatening bleeding. There was no difference in the number of participants with severe or life-threatening bleeding between a low-dose and a standard-dose platelet transfusion policy (three studies; 1059 participants; RR 1.33, 95% CI 0.91 to 1.92; low-quality evidence); low-dose and high-dose groups (one study; 849 participants; RR 1.20, 95% CI 0.82 to 1.77; low-quality evidence); or high-dose and standard-dose groups (one study; 855 participants; RR 1.11, 95% CI 0.73 to 1.68; low-quality evidence). Two studies reported the time to first bleeding episodes; we were unable to perform a meta-analysis. Both studies (959 participants) individually found that the time to first bleeding episode was either the same, or longer, in the low-dose group compared to the standard-dose group. One study (855 participants) found that the time to the first bleeding episode was the same in the high-dose group compared to the standard-dose group. Three studies reported all-cause mortality within 30 days from the start of the study. There was no difference in all-cause mortality between treatment arms (low-dose versus standard-dose: three studies; 1070 participants; RR 2.04, 95% CI 0.70 to 5.93; low-quality evidence; low-dose versus high-dose: one study; 849 participants; RR 1.33, 95% CI 0.50 to 3.54; low-quality evidence; and high-dose versus standard-dose: one study; 855 participants; RR 1.71, 95% CI 0.51 to 5.81; low-quality evidence). Six studies reported the number of platelet transfusions; we were unable to perform a meta-analysis. Two studies (959 participants) out of three (1070 participants) found that a low-dose transfusion strategy led to more transfusion episodes than a standard-dose. One study (849 participants) found that a low-dose transfusion strategy led to more transfusion episodes than a high-dose strategy. One study (855 participants) out of three (1007 participants) found no difference in the number of platelet transfusions between the high-dose and standard-dose groups. One study reported on transfusion reactions. This study’s authors suggested that a high-dose platelet transfusion strategy may lead to a higher rate of transfusion-related adverse events. None of the studies reported quality-of-life. Authors’ conclusions In haematology patients who are thrombocytopenic due to myelosuppressive chemotherapy or HSCT, we found no evidence to suggest that a low-dose platelet transfusion policy is associated with an increased bleeding risk compared to a standard-dose or high-dose policy, or that a high-dose platelet transfusion policy is associated with a decreased risk of bleeding when compared to a standard-dose policy. A low-dose platelet transfusion strategy leads to an increased number of transfusion episodes compared to a standard-dose strategy. A high-dose platelet transfusion strategy does not decrease the number of transfusion episodes per participant compared to a standard-dose regimen, and it may increase the number of transfusion-related adverse events. Findings from this review would suggest a change from current practice, with low-dose platelet transfusions used for people receiving in-patient treatment for their haematological disorder and high-dose platelet transfusion strategies not being used routinely. PMID:26505729
Saether, Erin E.; Chamberlain, Connie S.; Leiferman, Ellen M.; Kondratko-Mittnacht, Jaclyn R.; Li, Wan Ju; Brickson, Stacey L.; Vanderby, Ray
2013-01-01
Mesenchymal stem cells (MSCs) have potential therapeutic applications for musculoskeletal injuries due to their ability to differentiate into several tissue cell types and modulate immune and inflammatory responses. These immune-modulatory properties were examined in vivo during early stage rat medial collateral ligament healing. Two different cell doses (low dose 1×106 or high dose 4×106 MSCs) were administered at the time of injury and compared with normal ligament healing at days 5 and 14 post-injury. At both times, the high dose MSC group demonstrated a significant decrease in M2 macrophages compared to controls. At day 14, fewer M1 macrophages were detected in the low dose group compared to the high dose group. These results, along with significant changes in procollagen I, proliferating cells, and endothelialization suggest that MSCs can alter the cellular response during healing in a dose-dependent manner. The higher dose ligaments also had increased expression of several pro-inflammatory cytokines at day 5 (IL-1β, IFNγ, IL-2) and increased expression of IL-12 at day 14. Mechanical testing at day 14 revealed increased failure strength and stiffness in low dose ligaments compared to controls. Based on these improved mechanical properties, MSCs enhanced functional healing when applied at a lower dose. Different doses of MSCs uniquely affected the cellular response and cytokine expression in healing ligaments. Interestingly, the lower dose of cells proved to be most effective in improving functional properties. PMID:24174129
Bucklin, Mason H; Acquisto, Nicole M; Nelson, Catherine
2014-05-01
Previous studies have suggested the used of off-label recombinant factor VII (rFVIIa) increases the risk of thromboembolic events, but the effect of the dose of rFVIIa is not well described in the literature. All adult patients that received off-label rFVIIa from 2005-2012 were included in this single-center, retrospective cohort study. The primary endpoint was the incidence of a thromboembolic event in the low dose (<50 mcg/kg) compared to the high dose (≥50 mcg/kg) cohort. Secondary endpoints compared time to thromboembolic event, incidence of arterial compared to venous events, and mortality. There were 152 patients that received rFVIIa during the study period with 66 in the low dose cohort and 86 in the high dose cohort. Mean total dose of rFVIIa was 30.2 mcg/kg (SD ± 9.5 mcg/kg) in the low dose and 99.8 mcg/kg (SD ± 64.7 mcg/kg) in the high dose cohort (p=0.0001). The overall incidence of thromboembolic events was 12.5%. There were 12 (14%) events in the low dose cohort and seven (10.6%) in the high dose cohort, RR=0.76 (95% CI 0.31-1.82). There were no differences in any of the secondary outcomes. A higher incidence of thromboembolic events in cardiothoracic surgery (20.8%) and penetrating trauma patients (21.4%) was seen compared to the remaining cohort (6.7%). No significant difference in the incidence of thromboembolic events was seen between low dose versus high dose rFVIIa over a seven year period at our institution. However, due to the relatively low overall incidence and a small sample size, type II error may be present. Copyright © 2014 Elsevier Ltd. All rights reserved.
Clarke, Alan T.; Johnson, Paul C. D.; Hall, Gillian C.; Ford, Ian; Mills, Peter R.
2016-01-01
Background & Aims Occasional risk of serious liver dysfunction and autoimmune hepatitis during atorvastatin therapy has been reported. We compared the risk of hepatotoxicity in atorvastatin relative to simvastatin treatment. Methods The UK GPRD identified patients with a first prescription for simvastatin [164,407] or atorvastatin [76,411] between 1997 and 2006, but with no prior record of liver disease, alcohol-related diagnosis, or liver dysfunction. Incident liver dysfunction in the following six months was identified by biochemical value and compared between statin groups by Cox regression model adjusting for age, sex, year treatment started, dose, alcohol consumption, smoking, body mass index and comorbid conditions. Results Moderate to severe hepatotoxicity [bilirubin >60μmol/L, AST or ALT >200U/L or alkaline phosphatase >1200U/L] developed in 71 patients on atorvastatin versus 101 on simvastatin. Adjusted hazard ratio [AHR] for all atorvastatin relative to simvastatin was 1.9 [95% confidence interval 1.4–2.6]. High dose was classified as 40–80mg daily and low dose 10–20mg daily. Hepatotoxicity occurred in 0.44% of 4075 patients on high dose atorvastatin [HDA], 0.07% of 72,336 on low dose atorvastatin [LDA], 0.09% of 44,675 on high dose simvastatin [HDS] and 0.05% of 119,732 on low dose simvastatin [LDS]. AHRs compared to LDS were 7.3 [4.2–12.7] for HDA, 1.4 [0.9–2.0] for LDA and 1.5 [1.0–2.2] for HDS. Conclusions The risk of hepatotoxicity was increased in the first six months of atorvastatin compared to simvastatin treatment, with the greatest difference between high dose atorvastatin and low dose simvastatin. The numbers of events in the analyses were small. PMID:26983033
Pusuwan, Pawana; Tuntawiroon, Malulee; Sritongkul, Nopamol; Chaudakshetrin, Pachee; Nopmaneejumruslers, Cherdchai; Komoltri, Chulalak; Thepamongkhol, Kullathorn; Khiewvan, Benjapa; Tuchinda, Pongpija; Sriussadaporn, Sutin
2011-03-01
To compare the efficacy and cost-effectiveness of high and low dose regimens of I-131 treatment in patients with hyperthyroidism. One hundred fifty patients with proven hyperthyroidism were randomly allocated into the high (74 patients) and low (76 patients) dose regimen of I-131 treatment. Four patients of the high dose group and one patient of the low dose group were excluded because of lost follow-up. A gland-specific dosage was calculated on the estimated weight of thyroid gland and 24-hour I-131 uptake. The high and low I-131 dose regimens were 150 microCi/gm and 100 microCi/gm, respectively. The first mean radioiodine activity administered to the high and low dose group was 10.2 and 8 mCi, respectively. Repeated treatment was given to 25 patients of the high dose group and 40 patients of the low dose group. Clinical outcome and calculated costs for outpatient attendances, and laboratory tests together with initial and subsequent treatments were evaluated for one year after I-131 treatment. Elimination of hyperthyroidism that resulted in either euthyroidism or hypothyroidism was classified as therapeutic success. The cost effectiveness was also compared. At 6 months after treatment, 45 (64.3%) patients receiving high dose and 59 (78.7%) patients receiving low dose were hyperthyroidism. Clinical outcome at one year showed persistence of hyperthyroidism in 21 (30%) patients of the high dose regimen and 36 (48%) patients of the low dose regimen. At one year post treatment, it was demonstrated that the high dose regimen could eliminate hyperthyroidism in a significantly shorter time than the low dose regimen, i.e., 259.6 days and 305.5 days, respectively, p = 0.008). For the persistent hyperthyroid patients, the average total cost of treatment in the low dose group was significantly higher than that of the high dose group, i.e., 13,422.78 baht and 10,942.79 baht, respectively; p = 0.050). A high dose regimen of radioactive iodine treatment is more effective than the low dose regimen. The successful outcome of a high dose regimen occurred significantly earlier than that of the low dose regimen. For the persistent hyperthyroid patients, the average total cost in the low dose group was significantly higher than that of the high dose group.
[Protection and bidirectional effect of rhubarb anthraquinone and tannins for rats' liver].
Qin, Lu-shan; Zhao, Hai-ping; Zhao, Yan-ling; Ma, Zhi-jiel; Zeng, Ling-na; Zhang, Ya-ming; Zhang, Ping; Yan, Dan; Bai, Zhao-fang; Li, Yue; Hao, Qing-xiu; Zhao, Kui-jun; Wang, Jia-bo; Xiao, Xiao-he
2014-06-01
To compare the bidirectional effect of rhubarb total anthraquinone (TA) and total tannins (TT) on rats' liver. One hundred rats were randomly divided into 10 groups, i.e., the blank group, the model group, the blank + high dose TA group, the blank +low dose TA group, the blank + high dose TT group, the blank + low dose TT group, the model + high dose TA group, the model + low dose TA group, the model +high dose TT group, and the model + low dose TT group, 10 in each group. The carbon tetrachloride (CCI4) was used to prepare the acute liver injury rat model. TA and TT of rhubarb (at 5.40 g crude drugs/kg and 14.69 g crude drugs/kg) were intragastrically administrated to rats in all groups except the blank group and the model group, once daily for 6 successive days.The general state of rats, biochemical indices such as alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), laminin (LN), hyaluronic acid (HA), transforming growth factor beta1 (TGF-beta1), as well pathological results of rat liver tissues. Finally the protection laws of TA and TT for rats' liver were analyzed using factor analysis. Compared with the blank control group, all biochemical indices increased in the blank group (P < 0.05, P < 0.01). HA also increased in the blank + high dose TA group; AST, ALT, and HA also increased in the blank +high dose TT group (P < 0.05). Compared with the model group, AST, ALT, ALP, HA, and TGF-beta1 significantly decreased in the model + low dose TA group, the model + high dose TA group, the model + low dose TT group (P < 0.05, P < 0.01). Serum AST, ALT, and ALP also decreased in the model + high dose TT group (P < 0.05, P < 0.01). Pathological results showed that mild swollen liver cells in the model + high dose TA group. Fatty degeneration and fragmental necrosis around the central veins occurred in the blank + high dose TA group. The pathological injury was inproved in the model +low dose TA group. Two common factors, liver fibrosis and liver cell injury, were extracted by using factor analysis. TA showed stronger improvement of the two common factors than TT. Rhubarb TA and TT showed protective and harmful effects on rats' liver. At an equivalent dosage, TA had better liver protection than TT. High dose TT played a role in liver injury to some extent.
Johnson, Daniel J; Johnson, Christine C; Goobie, Susan M; Nami, Nina; Wetzler, Joshua A; Sponseller, Paul D; Frank, Steven M
2017-12-01
Our objective was to quantify blood loss and transfusion requirements for high-dose and low-dose tranexamic acid (TXA) dosing regimens in pediatric patients undergoing spinal fusion for correction of idiopathic scoliosis. Previous investigators have established the efficacy of TXA in pediatric scoliosis surgery; however, the dosing regimens vary widely and the optimal dose has not been established. We retrospectively analyzed electronic medical records for 116 patients who underwent spinal fusion surgery for idiopathic scoliosis by a single surgeon and were treated with TXA. In total, 72 patients received a 10 mg/kg loading dose with a 1 mg/kg/h maintenance dose (low-dose) and 44 patients received 50 mg/kg loading dose with a 5 mg/kg/h maintenance dose (high-dose). Estimated blood loss and transfusion requirements were compared between dosing groups. Patient characteristics were nearly identical between the 2 groups. Compared with the low-dose TXA group, the high-dose TXA group had decreased estimated blood loss (695 vs. 968 mL, P=0.01), and a decrease in both intraoperative (0.3 vs. 0.9 units, P=0.01) and whole hospitalization (0.4 vs. 1.0 units, P=0.04) red blood cell transfusion requirements. The higher-dose TXA was associated with decreased intraoperative (P=0.01), and whole hospital transfusion (P=0.01) requirements, even after risk-adjustment for potential confounding variables. High-dose TXA is more effective than low-dose TXA in reducing blood loss and transfusion requirements in pediatric idiopathic scoliosis patients undergoing surgery. Level-III, retrospective cohort study.
Wang, Juan; Chen, Dan; Li, Da-Bing; Yu, Xin; Shi, Guo-Bing
2016-09-01
Previous study indicated that high-dose statin treatment might increase the risk of hemorrhagic stroke and adverse reactions. We aim to compare the efficacy and safety of intensive-dose and standard-dose statin treatment for preventing stroke in high-risk patients. A thorough search was performed of multiple databases for publications from 1990 to June 2015. We selected the randomized clinical trials comparing standard-dose statin with placebo and intensive-dose statin with standard-dose statin or placebo for the prevention of stroke events in patients. Duplicate independent data extraction and bias assessments were performed. Data were pooled using a fixed-effects model or a random-effects model if significant heterogeneity was present. For the all stroke incidences, intensive-dose statin treatment compared with placebo treatment and standard-dose statin treatment compared with placebo treatment showed a significant 21% reduction in relative risk (RR) (RR 0.79, 95% confidence interval (CI) [0.71, 0.87], P < 0.00001) and an 18% reduction in RR (RR 0.82, 95% CI [0.73, 0.93], P = 0.002) in the subgroup without renal transplant recipients and patients undergoing regular hemodialysis separately. For the fatal stroke incidences, intensive-dose statin treatment compared with standard dose or placebo was effective reducing fatal stroke (RR 0.61, 95% CI [0.39, 0.96], P = 0.03) and the RR was 1.01 (95% CI [0.85, 1.20], P = 0.90) in standard-dose statin treatment compared with placebo. The results of this meta-analysis suggest that intensive-dose statin treatment might be more favorable for reducing the incidences of all strokes than standard-dose statin treatment, especially for patients older than 65 years in reducing the incidences of all stroke incidences.
Boon, Martijn; Martini, Chris; Yang, H Keri; Sen, Shuvayu S; Bevers, Rob; Warlé, Michiel; Aarts, Leon; Niesters, Marieke; Dahan, Albert
2018-01-01
Recent data shows that a neuromuscular block (NMB) induced by administration of high doses of rocuronium improves surgical conditions in certain procedures. However, there are limited data on the effect such practices on postoperative outcomes. We performed a retrospective analysis to compare unplanned 30-day readmissions in patients that received high-dose versus low-dose rocuronium administration during general anesthesia for laparoscopic retroperitoneal surgery. This retrospective cohort study was performed in the Netherlands in an academic hospital where routine high-dose rocuronium NMB has been practiced since July 2015. Charts of patients receiving anesthesia between January 2014 and December 2016 were searched for surgical cases receiving high-dose rocuronium and matched with respect to procedure, age, sex and ASA classification to patients receiving low-dose rocuronium. The primary post-operative outcome was unplanned 30-day readmission rate. There were 130 patients in each cohort. Patients in the high- and low-dose rocuronium cohorts received 217 ± 49 versus 37 ± 5 mg rocuronium, respectively. In the high-dose rocuronium group neuromuscular activity was consistently monitored; matched patients were unreliably monitored. All patients receiving high-dose rocuronium were reversed with sugammadex, while just 33% of matched patients were reversed with sugammadex and 20% with neostigmine; the remaining patients were not reversed. Unplanned 30-day readmission rate was significantly lower in the high-dose compared to the low-dose rocuronium cohort (3.8% vs. 12.7%; p = 0.03; odds ratio = 0.33, 95% C.I. 0.12-0.95). This small retrospective study demonstrates a lower incidence of unplanned readmissions within 30-days following laparoscopic retroperitoneal surgery with high-dose relaxant anesthesia and sugammadex reversal in comparison to low-dose relaxant anesthesia. Further prospective studies are needed in larger samples to corroborate our findings and additionally assess the pharmacoeconomics of high-dose relaxant anesthesia taking into account the benefits (reduced readmissions) and harm (cost of relaxants and reversal agents) of such practice.
NASA Astrophysics Data System (ADS)
Yusof, Mohd Fahmi Mohd; Yahya, Muhammad Hadzmi; Rosnan, Muhammad Syazwan; Abdullah, Reduan; Kadir, Ahmad Bazlie Abdul
2017-01-01
The dose measurement using Al2O3 OSL dosimeter (OSLD) was carried out at low and high energy x-ray. The dose at low energy x-ray was measured at 40, 71 and 125 kVp x-ray energies. The dose ar high energy x-ray was measured at 6 and 10 MV x-ray energies measured at the depth of maximum dose (Zmax). The results were compared to that in ionization chamber and LiF: Mg,Ti thermoluminescent dosimeters (TLD100). The results showed that the dose of OSLD were less in agreement to ionization chamber compared to that in TLD100. The dose of OSLD however was in good agreement to that in ionization chamber at high energy x-ray. The dose measured using OSLD were found to be more consistence at high energy x-ray shown by the standard deviation of the readings. The measurement of x2 showed that the readings of OSLD were close to that in ionization chamber with values of 2.21 and 4.63 for 6 and 10 MV respectively. The results indicated that OSLD is more suitable for dose measurement at high energy x-ray.
Minguetti-Câmara, Vania C; Marques, Any de C R; Schiavon, Fabiana P M; Vilela, Vanessa R; Bruschi, Marcos L; Bazotte, Roberto Barbosa
2014-10-21
We compared the effects of oral administration of high-dose or low-dose glutamine dipeptide (GDP), alanine (ALA), glutamine (GLN), and ALA + GLN on the blood availability of amino acids in rats submitted to insulin-induced hypoglycemia (IIH). Insulin detemir (1 U/kg) was intraperitoneally injected to produce IIH; this was followed by oral administration of GDP, GLN + ALA, GLN, or ALA. We observed higher blood levels of GLN, 30 min after oral administration of high-dose GDP (1000 mg/kg) than after administration of ALA (381 mg/kg) + GLN (619 mg/kg), GLN (619 mg/kg), or ALA (381 mg/kg). However, we did not observe the same differences after oral administration of low-dose GDP (100 mg/kg) compared with ALA (38.1 mg/kg) + GLN (61.9 mg/kg), GLN (61.9 mg/kg), or ALA (38.1 mg/kg). We also observed less liver catabolism of GDP compared to ALA and GLN. In conclusion, high-dose GDP promoted higher blood levels of GLN than oral ALA + GLN, GLN, or ALA. Moreover, the lower levels of liver catabolism of GDP, compared to ALA or GLN, contributed to the superior performance of high-dose GDP in terms of blood availability of GLN.
Kim, Dae Sik; Kang, Ka-Won; Lee, Se Ryeon; Park, Yong; Sung, Hwa Jung; Kim, Seok Jin; Choi, Chul Won; Kim, Byung Soo
2015-09-01
We compared the efficacy of high-dose cytarabine alone to that of intermediate-dose cytarabine combined with anthracyclines as consolidation therapy. Patients enrolled in the Korea University acute myeloid leukemia (AML) registry received remission induction chemotherapy with the same standard induction regimen (idarubicin and cytarabine 3 + 7). Postremission therapy was performed for three or four cycles according to one of the following regimens: high-dose cytarabine (3 g/m(2)) or combination of intermediate-dose cytarabine (1 g/m(2)) with anthracyclines (idarubicin or mitoxantrone). Among the 443 AML patients enrolled in the registry, 145 patients received consolidation chemotherapy. The median overall survival (OS) and relapse-free survival (RFS) in the high-dose cytarabine group were significantly longer than those in the anthracycline combination group (OS, not reached vs. 16.6 months, p = 0.045; RFS, 38.6 months vs. 11.0 months, p = 0.011). The median duration of neutropenia was longer in the anthracycline combination group than in the high-dose cytarabine group (8 vs. 10 days, p = 0.001). This study suggests that high-dose cytarabine consolidation may produce superior outcomes than combination treatment with intermediate-dose cytarabine and anthracyclines and that the addition of anthracyclines during AML consolidation has limited value as compared to cytarabine intensification.
Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.
Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L
1999-03-17
Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.
NASA Astrophysics Data System (ADS)
Zhao, Qian; Sun, Yeqing; Wang, Wei
2016-07-01
Highly ionizing radiation (HZE) in space is considered as a main factor causing biological effects on plant seeds. To investigate the different effects on genome-wide gene expression of low-dose and high-dose ion radiation, we carried out ground-base carbon particle HZE experiments with different cumulative doses (0Gy, 0.2Gy, 2Gy) to rice seeds and then performed comparative transcriptome analysis of the rice seedlings. We identified a total of 2551 and 1464 differentially expressed genes (DEGs) in low-dose and high-dose radiation groups, respectively. Gene ontology analyses indicated that low-dose and high-dose ion radiation both led to multiple physiological and biochemical activities changes in rice. By Gene Ontology analyses, the results showed that only one process-oxidation reduction process was enriched in the biological process category after high-dose ion radiation, while more processes such as response to biotic stimulus, heme binding, tetrapyrrole binding, oxidoreductase activity, catalytic activity and oxidoreductase activity were significantly enriched after low-dose ion radiation. The results indicated that the rice plants only focused on the process of oxidation reduction to response to high-dose ion radiation, whereas it was a coordination of multiple biological processes to response to low-dose ion radiation. To elucidate the transcriptional regulation of radiation stress-responsive genes, we identified several DEGs-encoding TFs. AP2/EREBP, bHLH, C2H2, MYB and WRKY TF families were altered significantly in response to ion radiation. Mapman analysis speculated that the biological effects on rice seedlings caused by the radiation stress might share similar mechanisms with the biotic stress. Our findings highlight important alterations in the expression of radiation response genes, metabolic pathways, and TF-encoding genes in rice seedlings exposed to low-dose and high-dose ion radiation.
Comparative toxicity of 4 commonly used intravitreal corticosteroids on rat retina.
Citirik, Mehmet; Dilsiz, Nihat; Batman, Cosar; Zilelioglu, Orhan
2009-06-01
To investigate the effects of 4 commonly used steroids (dexamethasone, triamcinolone, betamethasone, and methylprednisolone) on 50 retinas of 25 adult pigmented rats. Experimental animal study. Twenty-five pigmented Long-Evans male rats. Each steroid drug with 2 different doses (0.025 mL and 0.050 mL) was injected into the vitreous of each eye of 5 rats. The low drug dose was injected into the right eye and the high dose was injected into the left eye. Ten eyes of 5 randomly selected rats were used as a control group and intravitreal saline was injected into these eyes. Oxidative damage and intrinsic antioxidative capacity were determined by measuring retinal malondialdehyde (MDA) and glutathione (GSH) levels, respectively. No statistically meaningful difference was observed in retinal GSH and MDA measurements in the low- and high-dose triamcinolone (1 and 2 mg), low-dose betamethasone (0.075 mg), and low-dose dexamethasone (0.1 mg) groups, compared with the control group. Both doses of methylprednisolone (1.6 mg and 3.2 mg), high-dose betamethasone (0.15 mg), and high-dose dexamethasone (0.2 mg) markedly altered retinal GSH and MDA levels. The results of our study show that the toxicity of triamcinolone is not evident even in high doses. It may be used safely. We also suggest that intravitreal use of low doses of betamethasone and dexamethasone is safer than higher doses of these drugs and both doses of methylprednisolone.
Zhou, Rong-Yi; Wang, Jiao-Jiao; You, Yue; Sun, Ji-Chao; Song, Yu-Chen; Yuan, Hai-Xia; Han, Xin-Min
2017-05-01
To study the effect of baicalin on synaptosomal adenosine triphosphatase (ATPase) and lactate dehydrogenase (LDH) and its regulatory effect on the adenylate cyclase (AC)/cyclic adenosine monophosphate (cAMP)/protein kinase A (PKA) signaling pathway in rats with attention deficit hyperactivity disorder (ADHD). A total of 40 SHR rats were randomly divided into five groups: ADHD model, methylphenidate hydrochloride treatment (0.07 mg/mL), and low-dose (3.33 mg/mL), medium-dose (6.67 mg/mL), and high-dose (10 mg/mL) baicalin treatment (n=8 each). Eight WKY rats were selected as normal control group. Percoll density gradient centrifugation was used to prepare brain synaptosomes and an electron microscope was used to observe their structure. Colorimetry was used to measure the activities of ATPase and LDH in synaptosomes. ELISA was used to measure the content of AC, cAMP, and PKA. Compared with the normal control group, the ADHD model group had a significant reduction in the ATPase activity, a significant increase in the LDH activity, and significant reductions in the content of AC, cAMP, and PKA (P<0.05). Compared with the ADHD model group, the methylphenidate hydrochloride group and the medium- and high-dose baicalin groups had a significant increase in the ATPase activity (P<0.05), a significant reduction in the LDH activity (P<0.05), and significant increases in the content of AC, cAMP, and PKA (P<0.05). Compared with the methylphenidate hydrochloride group, the high-dose baicalin group had significantly greater changes in these indices (P<0.05). Compared with the low-dose baicalin group, the high-dose baicalin group had a significant increase in the ATPase activity (P<0.05); the medium- and high-dose baicalin groups had a significant reduction in the LDH activity (P<0.05) and significant increases in the content of AC, cAMP, and PKA (P<0.05). Compared with the medium-dose baicalin group, the high-dose baicalin group had a significant increase in the ATPase activity (P<0.05). Both methylphenidate hydrochloride and baicalin can improve synaptosomal ATPase and LDH activities in rats with ADHD. The effect of baicalin is dose-dependent, and high-dose baicalin has a significantly greater effect than methylphenidate hydrochloride. Baicalin exerts its therapeutic effect possibly by upregulating the AC/cAMP/PKA signaling pathway.
Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions
NASA Technical Reports Server (NTRS)
McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.
2012-01-01
Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.
Lui, Kung-Jong; Chang, Kuang-Chao
2015-01-01
When comparing two doses of a new drug with a placebo, we may consider using a crossover design subject to the condition that the high dose cannot be administered before the low dose. Under a random-effects logistic regression model, we focus our attention on dichotomous responses when the high dose cannot be used first under a three-period crossover trial. We derive asymptotic test procedures for testing equality between treatments. We further derive interval estimators to assess the magnitude of the relative treatment effects. We employ Monte Carlo simulation to evaluate the performance of these test procedures and interval estimators in a variety of situations. We use the data taken as a part of trial comparing two different doses of an analgesic with a placebo for the relief of primary dysmenorrhea to illustrate the use of the proposed test procedures and estimators.
Wang, Juan; Chen, Dan; Li, Da-Bing; Yu, Xin; Shi, Guo-Bing
2016-01-01
Abstract Background: Previous study indicated that high-dose statin treatment might increase the risk of hemorrhagic stroke and adverse reactions. We aim to compare the efficacy and safety of intensive-dose and standard-dose statin treatment for preventing stroke in high-risk patients. Methods: A thorough search was performed of multiple databases for publications from 1990 to June 2015. We selected the randomized clinical trials comparing standard-dose statin with placebo and intensive-dose statin with standard-dose statin or placebo for the prevention of stroke events in patients. Duplicate independent data extraction and bias assessments were performed. Data were pooled using a fixed-effects model or a random-effects model if significant heterogeneity was present. Results: For the all stroke incidences, intensive-dose statin treatment compared with placebo treatment and standard-dose statin treatment compared with placebo treatment showed a significant 21% reduction in relative risk (RR) (RR 0.79, 95% confidence interval (CI) [0.71, 0.87], P < 0.00001) and an 18% reduction in RR (RR 0.82, 95% CI [0.73, 0.93], P = 0.002) in the subgroup without renal transplant recipients and patients undergoing regular hemodialysis separately. For the fatal stroke incidences, intensive-dose statin treatment compared with standard dose or placebo was effective reducing fatal stroke (RR 0.61, 95% CI [0.39, 0.96], P = 0.03) and the RR was 1.01 (95% CI [0.85, 1.20], P = 0.90) in standard-dose statin treatment compared with placebo. Conclusion: The results of this meta-analysis suggest that intensive-dose statin treatment might be more favorable for reducing the incidences of all strokes than standard-dose statin treatment, especially for patients older than 65 years in reducing the incidences of all stroke incidences. PMID:27684837
Coward, Stephanie; Kuenzig, M Ellen; Hazlewood, Glen; Clement, Fiona; McBrien, Kerry; Holmes, Rebecca; Panaccione, Remo; Ghosh, Subrata; Seow, Cynthia H; Rezaie, Ali; Kaplan, Gilaad G
2017-03-01
Induction treatment of mild-to-moderate Crohn's disease is controversial. To compare the induction of remission between different doses of mesalamine, sulfasalazine, corticosteroids, and budesonide for active Crohn's disease. We identified randomized controlled trials from existing Cochrane reviews and an updated literature search in Medline, EMBASE, and CENTRAL to November 2015. We included randomized controlled trials (n = 22) in adult patients with Crohn's disease that compared budesonide, sulfasalazine, mesalamine, or corticosteroids with placebo or each other, for the induction of remission (8-17 wks). Mesalamine (above and below 2.4 g/d) and budesonide (above and below 6 mg/d) were stratified into low and high doses. Our primary outcome was remission, defined as a Crohn's Disease Activity Index score <150. A Bayesian random-effects network meta-analysis was performed on the proportion in remission. Corticosteroids (odds ratio [OR] = 3.80; 95% credible interval [CrI]: 2.48-5.66), high-dose budesonide (OR = 2.96; 95% CrI: 2.06-4.30), and high-dose mesalamine (OR = 2.29; 95% CrI: 1.58-3.33) were superior to placebo. Corticosteroids were similar to high-dose budesonide (OR = 1.21; 95% CrI: 0.84-1.76), but more effective than high-dose mesalamine (OR = 1.83; 95% CrI: 1.16-2.88). Sulfasalazine was not significantly superior to any therapy including placebo. Randomized controlled trials that use a strict definition of induction of remission and disease severity at enrollment to assess effectiveness in treating mild-to-moderate Crohn's disease are limited. Corticosteroids and high-dose budesonide were effective treatments for inducing remission in mild-to-moderate Crohn's disease. High-dose mesalamine is an option among patients preferring to avoid steroids.
High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.
Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri
2017-10-01
Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.
TH-A-9A-04: Incorporating Liver Functionality in Radiation Therapy Treatment Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, V; Epelman, M; Feng, M
2014-06-15
Purpose: Liver SBRT patients have both variable pretreatment liver function (e.g., due to degree of cirrhosis and/or prior treatments) and sensitivity to radiation, leading to high variability in potential liver toxicity with similar doses. This work aims to explicitly incorporate liver perfusion into treatment planning to redistribute dose to preserve well-functioning areas without compromising target coverage. Methods: Voxel-based liver perfusion, a measure of functionality, was computed from dynamic contrast-enhanced MRI. Two optimization models with different cost functions subject to the same dose constraints (e.g., minimum target EUD and maximum critical structure EUDs) were compared. The cost functions minimized were EUDmore » (standard model) and functionality-weighted EUD (functional model) to the liver. The resulting treatment plans delivering the same target EUD were compared with respect to their DVHs, their dose wash difference, the average dose delivered to voxels of a particular perfusion level, and change in number of high-/low-functioning voxels receiving a particular dose. Two-dimensional synthetic and three-dimensional clinical examples were studied. Results: The DVHs of all structures of plans from each model were comparable. In contrast, in plans obtained with the functional model, the average dose delivered to high-/low-functioning voxels was lower/higher than in plans obtained with its standard counterpart. The number of high-/low-functioning voxels receiving high/low dose was lower in the plans that considered perfusion in the cost function than in the plans that did not. Redistribution of dose can be observed in the dose wash differences. Conclusion: Liver perfusion can be used during treatment planning potentially to minimize the risk of toxicity during liver SBRT, resulting in better global liver function. The functional model redistributes dose in the standard model from higher to lower functioning voxels, while achieving the same target EUD and satisfying dose limits to critical structures. This project is funded by MCubed and grant R01-CA132834.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Jung, H; Kim, M
2014-06-01
Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulatedmore » dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.« less
Gabardi, Steven; Asipenko, Natalya; Fleming, James; Lor, Kevin; McDevitt-Potter, Lisa; Mohammed, Anisa; Rogers, Christin; Tichy, Eric M; Weng, Renee; Lee, Ruth-Ann
2015-07-01
Despite proven efficacy of prolonged cytomegalovirus (CMV) prophylaxis using valganciclovir 900 mg/day, some centers use 450 mg/day due to reported success and cost savings. This multicenter, retrospective study compared the efficacy and safety of 6 months of low-dose versus high-dose valganciclovir prophylaxis in high-risk, donor-positive/recipient-negative, renal transplant recipients (RTR). Two hundred thirty-seven high-risk RTR (low-dose group = valganciclovir 450 mg/day [n = 130]; high-dose group = valganciclovir 900 mg/day [n = s7]) were evaluated for 1-year CMV disease prevalence. Breakthrough CMV, resistant CMV, biopsy-proven acute rejection (BPAR), graft loss, opportunistic infections (OI), new-onset diabetes after transplantation (NODAT), premature valganciclovir discontinuation, renal function and myelosuppression were also assessed. Patient demographics and transplant characteristics were comparable. Induction and maintenance immunosuppression were similar, except for more early steroid withdrawal in the high-dose group. Similar proportions of patients developed CMV disease (14.6% vs 24.3%; P = 0.068); however, controlling CMV risk factor differences through multivariate logistic regression revealed significantly lower CMV disease in the low-dose group (P = 0.02; odds ratio, 0.432, 95% confidence interval, 0.211-0.887). Breakthrough and resistant CMV occurred at similar frequencies. There was no difference in renal function or rates of biopsy-proven acute rejection, graft loss, opportunistic infections, or new-onset diabetes after transplantation. The high-dose group had significantly lower mean white blood cell counts at months 5 and 6; however, premature valganciclovir discontinuation rates were similar. Low-dose and high-dose valganciclovir regimens provide similar efficacy in preventing CMV disease in high-risk RTR, with a reduced incidence of leukopenia associated with the low-dose regimen and no difference in resistant CMV. Low-dose valganciclovir may provide a significant cost avoidance benefit.
Khan, Nabeel; Abbas, Ali M; Koleva, Yordanka N; Bazzano, Lydia A
2013-05-01
There are limited data about the long-term follow-up of patients with ulcerative colitis (UC) maintained on high versus low doses of mesalamine. We evaluated the best long-term average daily dose that would keep the disease in remission. Nationwide ulcerative colitis data were obtained from the Veterans Affairs health care system for the period 2001 to 2011. Those who started mesalamine maintenance during this period were included. Average daily dose and the level of adherence were assessed for the period between the first mesalamine dispense and the date of first flare defined as the first filling of 40 mg/day or more of oral prednisone or any dose of intravenous steroids. Patients with ulcerative colitis maintained on an average daily dose 2.4 to 2.8 g/day (low dose) were compared with 4.4 to 4.8 g/day (high dose). Adherence was assessed using continuous single interval medication availability indicator. We included 4452 patients with a median follow-up of 6 years. There was no significant reduction in the risk of flares when comparing high versus low average mesalamine dose among patients with high [hazard ratio = 0.96, P = 0.8)] and medium (hazard ratio = 0.74, P = 0.17) adherence. However, there was a significant reduction in the risk of flares with high dose of mesalamine among patients with low adherence (hazard ratio = 0.28, P = 0.003). Our data show that when starting a patient on mesalamine, there is no difference in the long-term flare risk between low versus high average daily dose as long as the patients have a high to moderate level of adherence.
Ragavendran, J Vaigunda; Laferrière, André; Bennett, Gary J; Ware, Mark A; Gandhi, Wiebke; Bley, Keith; Schweinhardt, Petra; Coderre, Terence J
2016-10-01
This double-blind randomized controlled study was designed to evaluate the analgesic effects of topical treatments with clonidine (CLON) and pentoxifylline (PTX) tested alone or as low- and high-dose combinations in a human experimental model of pain. Of 69 healthy subjects aged 18 to 60 years, 23 each were randomly allocated to low-dose (0.04% + 2%) and high-dose (0.1% + 5%) CLON + PTX groups. Both of these groups also received their corresponding placebos in one of 2 treatment periods separated by at least 48 hours. Twenty-three additional subjects received either CLON (0.1%) or PTX (5%) as single drug treatments, in each of 2 treatment periods. Assessment of analgesic efficacy was based on allodynic effects of previous intraepidermal capsaicin injection, as well as postcapsaicin tourniquet-induced pain 50 minutes following capsaicin injection. Visual Analogue Scale (VAS) ratings of pain intensity and the area of dynamic mechanical allodynia were the primary outcome measures, whereas area of punctate mechanical allodynia (PMA) served as a secondary outcome measure. Topical treatments with high- or low-dose combinations significantly reduced VAS ratings compared with corresponding placebo treatments throughout the period of postcapsaicin tourniquet-induced pain. Importantly, the high-dose combination produced lower VAS ratings than CLON alone, which were lower than PTX alone. Results also revealed significant inhibition of postcapsaicin dynamic mechanical allodynia and PMA for the high-dose combination compared with placebo, and of PMA for CLON compared with the low-dose combination. Hence, the present data are supportive of further clinical investigation of the high-dose topical combination of CLON + PTX in complex regional pain syndrome and neuropathic pain patients, for which our preclinical data predict efficacy.
Barnwal, Neeraj Kumar; Umbarkar, Sanjeeta Rajendra; Sarkar, Manjula Sudeep; Dias, Raylene J
2017-01-01
Background: Pulmonary hypertension secondary to congenital heart disease is a common problem in pediatric patients presenting for open heart surgery. Milrinone has been shown to reduce pulmonary vascular resistance and pulmonary artery pressure in pediatric patients and neonates postcardiac surgery. We aimed to evaluate the postoperative outcome in such patients with three different fixed maintenance doses of milrinone. Methodology: Patients were randomized into three groups. All patients received fixed bolus dose of milrinone 50 μg/kg on pump during rewarming. Following this, patients in low-dose group received infusion of milrinone at the rate of 0.375 μg/kg/min, medium-dose group received 0.5 μg/kg/min, and high-dose group received 0.75 μg/kg/min over 24 h. Heart rate, mean arterial pressure (MAP), mean airway pressure (MaP), oxygenation index (OI), and central venous pressure (CVP) were compared at baseline and 24 h postoperatively. Dose of inotropic requirement, duration of ventilatory support and Intensive Care Unit (ICU) stay were noted. Results: MAP, MaP, OI, and CVP were comparable in all three groups postoperatively. All patients in the low-dose group required low inotropic support while 70% of patients in the high-dose group needed high inotropic support to manage episodes of hypotension (P = 0.000). Duration of ventilatory support and ICU stay in all three groups was comparable (P = 0.412, P = 0.165). Conclusion: Low-dose infusions while having a clinical impact were more beneficial in avoiding adverse events and decreasing inotropic requirement without affecting duration of ventilatory support and duration of ICU stay. PMID:28701597
Barnwal, Neeraj Kumar; Umbarkar, Sanjeeta Rajendra; Sarkar, Manjula Sudeep; Dias, Raylene J
2017-01-01
Pulmonary hypertension secondary to congenital heart disease is a common problem in pediatric patients presenting for open heart surgery. Milrinone has been shown to reduce pulmonary vascular resistance and pulmonary artery pressure in pediatric patients and neonates postcardiac surgery. We aimed to evaluate the postoperative outcome in such patients with three different fixed maintenance doses of milrinone. Patients were randomized into three groups. All patients received fixed bolus dose of milrinone 50 μg/kg on pump during rewarming. Following this, patients in low-dose group received infusion of milrinone at the rate of 0.375 μg/kg/min, medium-dose group received 0.5 μg/kg/min, and high-dose group received 0.75 μg/kg/min over 24 h. Heart rate, mean arterial pressure (MAP), mean airway pressure (MaP), oxygenation index (OI), and central venous pressure (CVP) were compared at baseline and 24 h postoperatively. Dose of inotropic requirement, duration of ventilatory support and Intensive Care Unit (ICU) stay were noted. MAP, MaP, OI, and CVP were comparable in all three groups postoperatively. All patients in the low-dose group required low inotropic support while 70% of patients in the high-dose group needed high inotropic support to manage episodes of hypotension (P = 0.000). Duration of ventilatory support and ICU stay in all three groups was comparable (P = 0.412, P = 0.165). Low-dose infusions while having a clinical impact were more beneficial in avoiding adverse events and decreasing inotropic requirement without affecting duration of ventilatory support and duration of ICU stay.
Safety of low-dose aspirin in endovascular treatment for intracranial atherosclerotic stenosis.
Ma, Ning; Xu, Ziqi; Mo, Dapeng; Gao, Feng; Gao, Kun; Sun, Xuan; Xu, Xiaotong; Liu, Lian; Song, Ligang; Wang, Tiejun; Zhao, Xingquan; Wang, Yilong; Wang, Yongjun; Miao, Zhongrong
2014-01-01
To evaluate the safety of low-dose aspirin plus clopidogrel versus high-dose aspirin plus clopidogrel in prevention of vascular risk within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment. From January 2012 to December 2013, this prospective and observational study enrolled 370 patients with symptomatic intracranial atherosclerotic stenosis of ≥70% with poor collateral undergoing intracranial endovascular treatment. Antiplatelet therapy consists of aspirin, at a low-dose of 100 mg or high-dose of 300 mg daily; clopidogrel, at a dose of 75 mg daily for 5 days before endovascular treatment. The dual antiplatelet therapy continued for 90 days after intervention. The study endpoints include acute thrombosis, subacute thrombosis, stroke or death within 90 days after intervention. Two hundred and seventy three patients received low-dose aspirin plus clopidogrel and 97 patients received high-dose aspirin plus clopidogrel before intracranial endovascular treatment. Within 90 days after intervention, there were 4 patients (1.5%) with acute thrombosis, 5 patients (1.8%) with subacute thrombosis, 17 patients (6.2%) with stroke, and 2 death (0.7%) in low-dose aspirin group, compared with no patient (0%) with acute thrombosis, 2 patient (2.1%) with subacute thrombosis, 6 patients (6.2%) with stroke, and 2 death (2.1%) in high-dose aspirin group, and there were no significant difference in all study endpoints between two groups. Low-dose aspirin plus clopidogrel is comparative in safety with high-dose aspirin plus clopidogrel within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment.
Arrieta, Antonio; Arguedas, Adriano; Fernandez, Pilar; Block, Stan L.; Emperanza, Paz; Vargas, Sergio L.; Erhardt, William A.; de Caprariis, Pascal J.; Rothermel, Constance D.
2003-01-01
Infants and young children, especially those in day care, are at risk for recurrent or persistent acute otitis media (AOM). There are no data on oral alternatives to high-dose amoxicillin-clavulanate for treating AOM in these high-risk patients. In this double-blind, double-dummy multicenter clinical trial, we compared a novel, high-dose azithromycin regimen with high-dose amoxicillin-clavulanate for treatment of children with recurrent or persistent AOM. Three hundred four children were randomized; 300 received either high-dose azithromycin (20 mg/kg of body weight once a day for 3 days) or high-dose amoxicillin-clavulanate (90 mg/kg divided twice a day for 10 days). Tympanocentesis was performed at baseline; clinical response was assessed at day 12 to 16 and day 28 to 32. Two-thirds of patients were aged ≤2 years. A history of recurrent, persistent, or recurrent plus persistent AOM was noted in 67, 18, and 14% of patients, respectively. Pathogens were isolated from 163 of 296 intent-to-treat patients (55%). At day 12 to 16, clinical success rates for azithromycin and amoxicillin-clavulanate were comparable for all patients (86 versus 84%, respectively) and for children aged ≤2 years (85 versus 79%, respectively). At day 28 to 32, clinical success rates for azithromycin were superior to those for amoxicillin-clavulanate for all patients (72 versus 61%, respectively; P = 0.047) and for those aged ≤2 years (68 versus 51%, respectively; P = 0.017). Per-pathogen clinical efficacy against Streptococcus pneumoniae and Haemophilus influenzae was comparable between the two regimens. The rates of treatment-related adverse events for azithromycin and amoxicillin-clavulanate were 32 and 42%, respectively (P = 0.095). Corresponding compliance rates were 99 and 93%, respectively (P = 0.018). These data demonstrate the efficacy and safety of high-dose azithromycin for treating recurrent or persistent AOM. PMID:14506028
``In Vivo'' Dosimetry in High Dose Rate Brachytherapy for Cervical Cancer Treatments
NASA Astrophysics Data System (ADS)
González-Azcorra, S. A.; Mota-García, A.; Poitevín-Chacón, M. A.; Santamaría-Torruco, B. J.; Rodríguez-Ponce, M.; Herrera-Martínez, F. P.; Gamboa de Buen, I.; Ruíz-Trejo, C.; Buenfil, A. E.
2008-08-01
In this prospective study, rectal dose was measured "in vivo" using TLD-100 crystals (3×3×1 mm3), and it has been compared to the prescribed dose. Measurements were performed in patients with cervical cancer classified in FIGO stages IB-IIIB and treated with high dose rate brachytherapy (HDR BT) at the Instituto Nacional de Cancerología (INCan).
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W
2012-10-17
Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. INTERVENTION The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. The composite of HIV disease progression or death from any cause. The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96-1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11-1.87) vs standard-dose supplementation. CONCLUSION In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Clinicaltrials.gov Identifier: NCT00383669.
San Miguel, Jesus F.; Weisel, Katja C.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Moreau, Philippe; Banos, Anne; Oriol, Albert; Garderet, Laurent; Cavo, Michele; Ivanova, Valentina; Alegre, Adrian; Martinez-Lopez, Joaquin; Chen, Christine; Renner, Christoph; Bahlis, Nizar Jacques; Yu, Xin; Teasdale, Terri; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Dimopoulos, Meletios A.
2015-01-01
Pomalidomide is a distinct oral IMiD® immunomodulatory agent with direct antimyeloma, stromal-support inhibitory, and immunomodulatory effects. The pivotal, multicenter, open-label, randomized phase 3 trial MM-003 compared pomalidomide + low-dose dexamethasone vs high-dose dexamethasone in 455 patients with refractory or relapsed and refractory multiple myeloma after failure of bortezomib and lenalidomide treatment. Initial results demonstrated significantly longer progression-free survival and overall survival with an acceptable tolerability profile for pomalidomide + low-dose dexamethasone vs high-dose dexamethasone. This secondary analysis describes patient outcomes by treatment history and depth of response. Pomalidomide + low-dose dexamethasone significantly prolonged progression-free survival and favored overall survival vs high-dose dexamethasone for all subgroups analyzed, regardless of prior treatments or refractory status. Both univariate and multivariate analyses showed that no variable relating to either the number (≤ or > 3) or type of prior treatment was a significant predictor of progression-free survival or overall survival. No cross-resistance with prior lenalidomide or thalidomide treatment was observed. Patients achieving a minimal response or better to pomalidomide + low-dose dexamethasone treatment experienced a survival benefit, which was even higher in those achieving at least a partial response (17.2 and 19.9 months, respectively, as compared with 7.5 months for patients with less than minimal response). These data suggest that pomalidomide + low-dose dexamethasone should be considered a standard of care in patients with refractory or relapsed and refractory multiple myeloma regardless of prior treatment. ClinicalTrials.gov: NCT01311687; EudraCT: 2010-019820-30. PMID:26160879
Roe, Matthew T; Green, Cynthia L; Giugliano, Robert P; Gibson, C Michael; Baran, Kenneth; Greenberg, Mark; Palmeri, Sebastian T; Crater, Suzanne; Trollinger, Kathleen; Hannan, Karen; Harrington, Robert A; Krucoff, Mitchell W
2004-02-18
This sub-study of the Integrilin and Tenecteplase in Acute Myocardial Infarction (INTEGRITI) trial evaluated of the impact of combination reperfusion therapy with reduced-dose tenecteplase plus eptifibatide on continuous ST-segment recovery and angiographic results. Combination therapy with reduced-dose fibrinolytics and glycoprotein IIb/IIIa inhibitors for ST-segment elevation myocardial infarction improves biomarkers of reperfusion success but has not reduced mortality when compared with full-dose fibrinolytics. We evaluated 140 patients enrolled in the INTEGRITI trial with 24-h continuous 12-lead ST-segment monitoring and angiography at 60 min. The dose-combination regimen of 50% of standard-dose tenecteplase (0.27 microg/kg) plus high-dose eptifibatide (2 boluses of 180 microg/kg separated by 10 min, 2.0 microg/kg/min infusion) was compared with full-dose tenecteplase (0.53 microg/kg). The dose-confirmation regimen of reduced-dose tenecteplase plus high-dose eptifibatide was associated with a faster median time to stable ST-segment recovery (55 vs. 98 min, p = 0.06), improved stable ST-segment recovery by 2 h (89.6% vs. 67.7%, p = 0.02), and less recurrent ischemia (34.0% vs. 57.1%, p = 0.05) when compared with full-dose tenecteplase. Continuously updated ST-segment recovery analyses demonstrated a modest trend toward greater ST-segment recovery at 30 min (57.7% vs. 40.6%, p = 0.13) and 60 min (82.7% vs. 65.6%, p = 0.08) with this regimen. These findings correlated with improved angiographic results at 60 min. Combination therapy with reduced-dose tenecteplase and eptifibatide leads to faster, more stable ST-segment recovery and improved angiographic flow patterns, compared with full-dose tenecteplase. These findings question the relationship between biomarkers of reperfusion success and clinical outcomes.
[Protective effect of emodin pretreatment in young rats with intrahepatic cholestasis].
Xiong, Xiao-Li; Yan, Su-Qi; Qin, Huan; Zhou, Li-Shan; Zhang, Ling-Ling; Jiang, Zhi-Xia; Ding, Yan
2016-02-01
To investigate the protective effect of emodin in young rats with intrahepatic cholestasis. A total of 120 young Sprague-Dawley rats were randomly divided into control, model, and high-, medium-, and low-dose emodin groups, with 24 rats in each group. The rats in the control and model groups were given sodium carboxymethyl cellulose solution by gavage, while the other groups were given different doses of emodin solution by gavage. On the 5th day of experiment, alpha-naphthylisothiocyanate (ANIT, 50 mg/kg) was applied by gavage to establish the model of intrahepatic cholestasis in all groups except the control group. At 24, 48, and 72 hours after gavage, 8 rats in each group were sacrificed. Colorimetry was used to measure the serum levels of total bilirubin (TBIL), direct bilirubin (DBIL), total bile acid (TBA), alkaline phosphatase (ALP), gamma glutamyl transpeptidase (GGT), alanine aminotransferase (ALT), and aspartate aminotransferase (AST) in each group, and hematoxylin-eosin staining was applied to observe the morphological changes of the liver under a light microscope at different time points. Compared with the control group, the model group had significantly increased serum levels of TBIL, DBIL, TBA, ALP, GGT, ALT, and AST at the 24-hour, 48-hour, and 72-hour time points (P<0.01). In the model group, the serum levels of TBIL, DBIL, TBA, ALT, and AST showed varying degrees of increase at 48 hours after establishment of model, compared with the values at 24 and 72 hours (P<0.05). At 24, 48, and 72 hours, the high-, medium-, and low-dose emodin groups had varying degrees of reductions in the serum levels of TBIL and TBA compared with the model group (P<0.05); the high- and low-dose emodin groups had significantly increased serum levels of TBA compared with the medium-dose emodin group (P<0.05). The model group had the most severe pathological changes at 48 hours. Compared with the model group, the high-, medium-, and low-dose emodin groups showed certain improvement in pathological changes of the liver at each time point, and the medium-dose emodin group had better improvement compared with the high- and low-dose emodin groups. Emodin can effectively improve ANIT-induced intrahepatic cholestasis in young rats, and medium-dose emodin shows the best effect.
Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rai, Bhavana; Patel, Firuza D., E-mail: firuzapatel@gmail.com; Chakraborty, Santam
2013-04-01
Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the secondmore » application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.« less
Dose rate in brachytherapy using after-loading machine: pulsed or high-dose rate?
Hannoun-Lévi, J-M; Peiffert, D
2014-10-01
Since February 2014, it is no longer possible to use low-dose rate 192 iridium wires due to the end of industrial production of IRF1 and IRF2 sources. The Brachytherapy Group of the French society of radiation oncology (GC-SFRO) has recommended switching from iridium wires to after-loading machines. Two types of after-loading machines are currently available, based on the dose rate used: pulsed-dose rate or high-dose rate. In this article, we propose a comparative analysis between pulsed-dose rate and high-dose rate brachytherapy, based on biological, technological, organizational and financial considerations. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Park, Jeong Bae; Ha, Jong-Won; Jung, Hae-Ok; Rhee, Moo-Yong
2014-10-01
Measurement of central blood pressure provides prognostic information beyond conventional peripheral blood pressure (BP). However, few studies have directly compared the effects of antihypertensives on central hemodynamics. This study investigated the effects of a low-dose combination of nifedipine Gastrointestinal Therapeutic System (GITS) and valsartan versus high-dose monotherapy with either agent in reducing central BP in essential hypertension inadequately controlled by low-dose monotherapy. In this prospective, open-label, randomized, active-controlled, multicenter 8-week study, patients not meeting the target BP after 4 weeks of treatment with low-dose monotherapy were randomized to receive nifedipine GITS 30 mg plus valsartan 80 mg (N30+V80), nifedipine GITS 60 mg (N60), or valsartan 160 mg (V160) for a further 4 weeks. Central hemodynamics were measured by applanation tonometry. A total of 391 patients were enrolled. Reduction in central systolic BP from baseline to week 8, the primary efficacy variable, was significantly greater in the N30+V80 group (-27.2±14.7 mmHg) and the N60 group (-27.1±16.5 mmHg) compared with V160 group (-14.4±16.6 mmHg). Decrease in the augmentation index in the N60 group was significantly greater compared with V160 alone, without differences between combination therapy and either high-dose monotherapy. Decreases in brachial systolic BP were significantly greater in the N30+V80 and N60 groups than in the V160 group. By multiple regression analysis, most differences in drug effects on central hemodynamics disappeared after controlling for changes in peripheral BP. A low rate of adverse events occurred in all treatment groups. A low-dose combination of nifedipine GITS plus valsartan or high-dose nifedipine was more effective in improving central hemodynamics than high-dose valsartan in patients with hypertension, mostly because of the improvement in peripheral (brachial) hemodynamics.
Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI
2013-10-01
Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less
Rühm, Werner; Azizova, Tamara; Bouffler, Simon; Cullings, Harry M; Grosche, Bernd; Little, Mark P; Shore, Roy S; Walsh, Linda; Woloschak, Gayle E
2018-01-01
Abstract In order to quantify radiation risks at exposure scenarios relevant for radiation protection, often extrapolation of data obtained at high doses and high dose rates down to low doses and low dose rates is needed. Task Group TG91 on ‘Radiation Risk Inference at Low-dose and Low-dose Rate Exposure for Radiological Protection Purposes’ of the International Commission on Radiological Protection is currently reviewing the relevant cellular, animal and human studies that could be used for that purpose. This paper provides an overview of dose rates and doses typically used or present in those studies, and compares them with doses and dose rates typical of those received by the A-bomb survivors in Japan. PMID:29432579
High-resolution low-dose scanning transmission electron microscopy.
Buban, James P; Ramasse, Quentin; Gipson, Bryant; Browning, Nigel D; Stahlberg, Henning
2010-01-01
During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biological specimens require a much reduced electron dose for high-resolution imaging. We describe here protocols for low-dose STEM image recording with a conventional field-emission gun STEM, while maintaining the high-resolution capability of the instrument. Our findings show that a combination of reduced pixel dwell time and reduced gun current can achieve radiation doses comparable to low-dose TEM.
Gariani, Joanna; Martin, Steve P; Botsikas, Diomidis; Becker, Christoph D; Montet, Xavier
2018-06-14
To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.
Narula, Neeraj; Cooray, Mohan; Anglin, Rebecca; Muqtadir, Zack; Narula, Alisha; Marshall, John K
2017-02-01
To assess the tolerability and efficacy of high-dose vitamin D3 in patients with Crohn's disease (CD). This was a randomized, double-blind placebo-controlled trial of high-dose vitamin D3 at 10,000 IU daily (n = 18) compared to 1000 IU daily (n = 16) for 12 months in patients with CD in remission. The primary outcome was change in serum 25-hydroxy-vitamin D levels. Secondary outcomes included clinical relapse rates and changes in mood scores. High-dose vitamin D3 at 10,000 IU daily significantly improved 25-hydroxy-vitamin D levels from a mean of 73.5 nmol/L [standard deviation (SD) 11.7 nmol/L] to 160.8 nmol/L (SD 43.2 nmol/L) (p = 0.02). On an intention-to-treat basis, the rate of relapse was not significantly different between patients receiving low- and high-dose vitamin D3 (68.8 vs 33.3%, p = 0.0844). In per-protocol analysis, clinical relapse of Crohn's disease was less frequently observed in patients receiving a high dose (0/12 or 0%) compared to those receiving a low dose of 1000 IU daily (3/8 or 37.5%) (p = 0.049). Improvement in anxiety and depression scores and a good safety profile were observed in both groups treated with vitamin D3. Oral supplementation with high-dose vitamin D3 at 10,000 IU daily significantly improved serum 25-hydroxy-vitamin D levels. Rates of clinical relapse were similar between both groups. Larger studies using high-dose vitamin D3 for treatment of inflammatory bowel diseases are warranted. CLINICALTRIALS. NCT02615288.
Einstein, Andrew J.; Blankstein, Ron; Andrews, Howard; Fish, Mathews; Padgett, Richard; Hayes, Sean W.; Friedman, John D.; Qureshi, Mehreen; Rakotoarivelo, Harivony; Slomka, Piotr; Nakazato, Ryo; Bokhari, Sabahat; Di Carli, Marcello; Berman, Daniel S.
2015-01-01
SPECT myocardial perfusion imaging (MPI) plays a central role in coronary artery disease diagnosis; but concerns exist regarding its radiation burden. Compared to standard Anger-SPECT (A-SPECT) cameras, new high-efficiency (HE) cameras with specialized collimators and solid-state cadmium-zinc-telluride detectors offer potential to maintain image quality (IQ), while reducing administered activity and thus radiation dose to patients. No previous study has compared IQ, interpretation, total perfusion deficit (TPD), or ejection fraction (EF) in patients receiving both ultra-low-dose (ULD) imaging on a HE-SPECT camera and standard low-dose (SLD) A-SPECT imaging. Methods We compared ULD-HE-SPECT to SLD-A-SPECT imaging by dividing the rest dose in 101 patients at 3 sites scheduled to undergo clinical A-SPECT MPI using a same day rest/stress Tc-99m protocol. Patients received HE-SPECT imaging following an initial ~130 MBq (3.5mCi) dose, and SLD-A-SPECT imaging following the remainder of the planned dose. Images were scored visually by 2 blinded readers for IQ and summed rest score (SRS). TPD and EF were assessed quantitatively. Results Mean activity was 134 MBq (3.62 mCi) for ULD-HE-SPECT (effective dose 1.15 mSv) and 278 MBq (7.50 mCi, 2.39 mSv) for SLD-A-SPECT. Overall IQ was superior for ULD-HE-SPECT (p<0.0001), with twice as many studies graded excellent quality. Extracardiac activity and overall perfusion assessment were similar. Between-method correlations were high for SRS (r=0.87), TPD (r=0.91), and EF (r=0.88). Conclusion ULD-HE-SPECT rest imaging correlates highly with SLD-A-SPECT. It has improved image quality, comparable extracardiac activity, and achieves radiation dose reduction to 1 mSv for a single injection. PMID:24982439
Pierce, Dwayne A; Russell, Greg; Pirkle, James L
2015-12-01
Hyperkalemia is a potentially life-threatening condition that is common in kidney disease patients. Insulin is used to treat hyperkalemia, but may cause hypoglycemia, especially in kidney disease when insulin may be metabolized more slowly. We compared the rates of hypoglycemia in patients with low estimated glomerular filtration rate (eGFR) using high versus low doses of insulin for hyperkalemia to determine if lower doses of insulin would decrease the incidence of hypoglycemia. This was a retrospective study of hospitalized patients receiving intravenous insulin for hyperkalemia during a 6-month period. Patients with low eGFR were analyzed based on how much insulin they received: high dose (10 units, n = 78) versus low dose (5 units, n = 71). Postdose nadir blood glucose values were examined for up to 8 hours after the dose. The percentage of hypoglycemia (blood glucose ≤70 mg/dl) and a subset of severe hypoglycemia (blood glucose <50 mg/dl) were then reported for each dose group. A total of 149 doses were identified in patients with low eGFR. The rates of hypoglycemia were 16.7% and 19.7% (P = 0.79), respectively, among high-dose (n = 78) and low-dose (n = 71) groups. Rates of severe hypoglycemia were 8.9% and 7.0%, respectively (P = 0.90). More than 28% of hypoglycemic episodes with high doses occurred after 4 hours (median = 2.5 hours) compared with 14.3% with low doses (median = 2.38 hours). There was no difference in the rate of hypoglycemia or severe hypoglycemia between high or low doses of insulin in patients with low eGFR. We recommend monitoring up to 6 hours after insulin use in hyperkalemia. © The Author(s) 2015.
Church, Kara M; Henalt, Robert; Baker, Errol; Smith, Gary L; Brennan, Michael T; Joseph, Jacob
2015-12-01
To determine if metoprolol succinate or carvedilol is more effective in delaying the time to first cardiovascular disease hospital admission in systolic heart failure patients. As a secondary objective, to determine the most effective dose of each agent in delaying first cardiovascular disease hospital admission, including but not limited to heart failure exacerbation, myocardial infarction, ischemic heart disease, cardiac arrhythmias, or death. This study was a retrospective chart review of 272 veterans at the VA Boston Healthcare System newly started on metoprolol succinate (n = 157) or carvedilol (n = 115) between January 2000 and December 2008. After an 8-week study medication titration period, subjects were subcategorized into low-, medium-, and high-dose ranging groups and followed until the first cardiovascular disease hospitalization, death, or 365 days. The main outcome measure was time to first cardiovascular hospitalization or death. The mean age (69.9 years vs. 67.9 years) and ejection fraction (26% vs. 25%) were comparable between study arms at baseline. Mean time to first cardiovascular disease hospitalization was significantly different (p = 0.001) between study groups with 330.6 days with in metoprolol succinate group vs. 282.6 days in the carvedilol groups. High-dose carvedilol significantly delayed time to first hospitalization in comparison to medium or low carvedilol doses (p = 0.015, p = 0.005). Low- and high-dose metoprolol succinate were not significantly different (p = 0.509) in time to first event, and both dosing groups fared better compared to medium dose metoprolol succinate (p = 0.046). In this veteran patient population in need of additional heart failure treatments, metoprolol succinate use resulted in a delayed time to first cardiovascular disease hospitalization or death compared to carvedilol. Both low and high doses of metoprolol succinate showed a significant delay of time to first cardiovascular hospitalization compared to medium doses of metoprolol succinate. Higher doses of carvedilol showed a significant delay of time to cardiovascular hospitalization than lower carvedilol doses. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Houweling, Antonetta C.; Crama, Koen; Visser, Jorrit; Fukata, Kyohei; Rasch, Coen R. N.; Ohno, Tatsuya; Bel, Arjan; van der Horst, Astrid
2017-04-01
Radiotherapy using charged particles is characterized by a low dose to the surrounding healthy organs, while delivering a high dose to the tumor. However, interfractional anatomical changes can greatly affect the robustness of particle therapy. Therefore, we compared the dosimetric impact of interfractional anatomical changes (i.e. body contour differences and gastrointestinal gas volume changes) in photon, proton and carbon ion therapy for pancreatic cancer patients. In this retrospective planning study, photon, proton and carbon ion treatment plans were created for 9 patients. Fraction dose calculations were performed using daily cone-beam CT (CBCT) images. To this end, the planning CT was deformably registered to each CBCT; gastrointestinal gas volumes were delineated on the CBCTs and copied to the deformed CT. Fraction doses were accumulated rigidly. To compare planned and accumulated dose, dose-volume histogram (DVH) parameters of the planned and accumulated dose of the different radiotherapy modalities were determined for the internal gross tumor volume, internal clinical target volume (iCTV) and organs-at-risk (OARs; duodenum, stomach, kidneys, liver and spinal cord). Photon plans were highly robust against interfractional anatomical changes. The difference between the planned and accumulated DVH parameters for the photon plans was less than 0.5% for the target and OARs. In both proton and carbon ion therapy, however, coverage of the iCTV was considerably reduced for the accumulated dose compared with the planned dose. The near-minimum dose ({{D}98 % } ) of the iCTV reduced with 8% for proton therapy and with 10% for carbon ion therapy. The DVH parameters of the OARs differed less than 3% for both particle modalities. Fractionated radiotherapy using photons is highly robust against interfractional anatomical changes. In proton and carbon ion therapy, such changes can severely reduce the dose coverage of the target.
Molecular and Histopathological Changes in Mouse Intestinal Tissue After Proton Exposure
NASA Technical Reports Server (NTRS)
Purgason, Ashley; Wu, Honglu
2010-01-01
Whole body exposure to protons in mice causes significant apoptosis in the crypts of the small intestine. Increasing numbers of crypts contained more apoptotic lesions as the dose of exposure increased. 16 genes associated with apoptotic pathways were shown to have significantly altered expression as compared to control samples for at least one of the doses of proton exposure 1 gene, Trp53inp1, was significantly up-regulated across all three doses. Those animals exposed to 0.1 Gy of proton irradiation showed greater amounts of significant alterations in gene expression as compared to 1 Gy and 2 Gy exposures. The differences in gene expression changes of low and high dose proton irradiated mice may offer insight into the molecular mechanisms of the possible high sensitivity at low proton doses. RAIDD (CRADD) may be responsible for the hypersensitivity observed in the duodenum of mice exposed to low doses of protons. Caspase-1 may also play a role in the hypersensitivity seen following proton irradiation at a dose of 0.1 Gy. FOXO3A may be involved in the down-regulation of GILZ observed at high doses of proton exposure.
Ajiwhen, I O; Bisong, S A
2013-12-20
Carpolobia lutea, commonly called cattle stick or poor man's candle, is used by traditional herbalists in eastern Nigeria to treat 'madness'. It has a reported analgesic and anti-nociceptive effect. The effect of its ethanolic root extract on learning and memory was investigated. Thirty mice were divided into three groups of ten each. One group of mice served as the control and was given normal saline (p.o.) while the other two groups were given acute low dose (1500mg/kg, p.o.) and high dose (2500mg/kg, p.o.) (LD50 3338.83mg/kg). The effect of the extract on cognitive memory was investigated using the Novel Object recognition task (NORT) while the effect on visuospatial learning and memory was studied using the Morris Water maze (MWM). The results obtained in the NORT show that the index of habituation was significantly lower following acute treatment with a low dose of C. lutea extract compared to control. However, the index of habituation did not differ following treatment with a high dose of C. lutea compared to control but it was higher compared to the low dose. Following treatment with a low dose of the extract, the index of discrimination was significantly higher compared to control. The index of discrimination in the high dose treatment group did not differ from control, but it was lower compared to the low dose treatment. This indicated that there was improved cognitive memory only in the low dose treatment group. In the MWM there was no significant difference in swim latency during Acquisition and Reversal training. There also was no significant difference in quadrant duration during probe trial. The swim latency during the visible platform test showed that all mice used had good visual acuity. Therefore, the ethanolic extract of C. lutea root enhanced cognitive memory. However it did not affect visuospatial learning and memory.
Developmental toxicity study of D-tagatose in rats.
Kruger, C L; Whittaker, M H; Frankos, V H; Schroeder, R E
1999-04-01
D-tagatose is a low-calorie sweetener that tastes like sucrose. The developmental toxicity of D-tagatose was investigated in Crl:CD(SD)BR rats administered D-tagatose at three dose levels (4000, 12,000, and 20,000 mg/kg body wt/day) via gastric intubation on days 6-15 of gestation. No compound-related toxicity was seen among any of the maternal groups. No treatment-related clinical effects were seen in the maternal animals at the 4000 mg/kg/day dose level. At the mid- and high-dose levels, most maternal animals had unformed or watery stools; this effect was most prominent early in the treatment period (Gestation Days 6-8). This effect was attributed to the osmotic effect of the large amount of D-tagatose given to the animals at these doses. Since D-tagatose is not digested or absorbed to a large extent, most of the sugar passes into the colon where it absorbs water and is fermented by colonic bacteria. Mean weight gain for the low- and mid-dose animals was comparable to the control; however, the high-dose group experienced a mean weight loss over the Gestation Day 6-9 interval. Over the entire treatment interval, however, mean weight gain for the high-dose animals was comparable to control. The decreased weight gain in the high-dose animals during the Gestation Day 6-9 interval was considered to be a direct result of laxation. In addition to the effect of laxation on body weight, reduced food consumption also contributed to the decreased weight gain. In the low-dose animals, no effect on food consumption was seen; however, both mid- and high-dose animals had food consumption values that were statistically significantly lower than the control. Food consumption was lowest during the Gestation Day 6-9 interval, the period when laxation was most prominent. Food consumption rebounded and was statistically significantly higher than the control for the mid- and high-dose animals during the posttreatment interval. Maternal liver weight for the low-dose animals was comparable to the control. However, a statistically significant increase in mean maternal liver weight was noted for the mid-and high-dose animals. Based on a lack of any corresponding histopathology, the increased liver weights were not considered toxicologically significant. There were no adverse effects on reproductive performance noted in any treatment group. No adverse treatment-related fetal effects on fetal weight, sex distribution, liver weight, or external, skeletal, or visceral malformations were noted at any dose level. Copyright 1999 Academic Press.
NASA Astrophysics Data System (ADS)
Kavetskyy, T.; Iida, K.; Nagashima, Y.; Kuczumow, A.; Šauša, O.; Nuzhdin, V.; Valeev, V.; Stepanov, A. L.
2017-01-01
The Doppler broadening slow positron beam spectroscopy (SPBS) data for the previously observed effect of carbonization in high-dose (>1016 ion/cm2) 40 keV boron-ion-implanted polymethylmethacrylate (B:PMMA) and another one obtained for the effect of formation of metal nanoparticles in high-dose 30 keV silver-ion-implanted polymer (Ag:PMMA) are compared. Following to the Doppler broadening SPBS results, a difference in the high-dose ion-irradiation-induced processes in B:PMMA and Ag:PMMA is detected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heintz, P; Heintz, B; Sandoval, D
Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. Themore » subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.« less
Spellman, Timothy; McClintock, Shawn M.; Terrace, Herbert; Luber, Bruce; Husain, Mustafa M.; Lisanby, Sarah H.
2008-01-01
Background Magnetic seizure therapy (MST) is under investigation as an alternative form of convulsive therapy that induces more focal seizures and spares cortical regions involved in memory. Using a newly expanded version of the Columbia University Primate Cognitive Profile, we compared the cognitive effects of high-dose MST delivered at 100 Hz (6X seizure threshold) with electroconvulsive shock (ECS) delivered at 2.5X seizure threshold. Methods Daily high-dose MST, ECS, and Sham (anesthesia-only) were administered for 4 weeks each in a within-subject cross-over design. Rhesus macaques (n = 3) were trained on five cognitive tasks assessing automatic memory, anterograde learning and memory, combined anterograde and retrograde simultaneous chaining, and spatial and serial working memory. Acutely following each intervention, monkeys were tested on the cognitive battery twice daily, separated by a 3-hour retention interval. Results Subjects were slower to complete criterion tasks (p’s<0.0001) following ECS, compared to sham and high-dose MST. Moreover, time to task-completion following high-dose MST did not differ from sham. Out of 6 measures of accuracy, treatment effects were found in 4; in all of these, ECS, but not MST, fared worse than Sham. On all accuracy and time to completion measurements, subjects performed as well as following high-dose MST as did subjects from a previous study on moderate-dose MST. Conclusion These findings provide evidence that high-dose MST results in benign acute cognitive side-effect profile relative to ECS, and are in line with our previous studies. PMID:18262171
Tang, Ning; Zhang, Qianqian; Fang, Shu; Han, Xiao; Wang, Zhehai
2017-01-01
Treatment of non-small-cell lung cancer (NSCLC) with wild-type epidermal growth factor receptor (EGFR) is still a challenge. This study explored antitumor activity of high-dose icotinib (an EGFR tyrosine kinase inhibitor) plus sequential docetaxel against wild-type EGFR NSCLC cells-generated nude mouse xenografts. Nude mice were subcutaneously injected with wild-type EGFR NSCLC A549 cells and divided into different groups for 3-week treatment. Tumor xenograft volumes were monitored and recorded, and at the end of experiments, tumor xenografts were removed for Western blot and immunohistochemical analyses. Compared to control groups (negative control, regular-dose icotinib [IcoR], high-dose icotinib [IcoH], and docetaxel [DTX]) and regular icotinib dose (60 mg/kg) with docetaxel, treatment of mice with a high-dose (1200 mg/kg) of icotinib plus sequential docetaxel for 3 weeks (IcoH-DTX) had an additive effect on suppression of tumor xenograft size and volume (P < 0.05). Icotinib-containing treatments markedly reduced phosphorylation of EGFR, mitogen activated protein kinase (MAPK), and protein kinase B (Akt), but only the high-dose icotinib-containing treatments showed an additive effect on CD34 inhibition (P < 0.05), an indication of reduced microvessel density in tumor xenografts. Moreover, high-dose icotinib plus docetaxel had a similar effect on mouse weight loss (a common way to measure adverse reactions in mice), compared to the other treatment combinations. The study indicate that the high dose of icotinib plus sequential docetaxel (IcoH-DTX) have an additive effect on suppressing the growth of wild-type EGFR NSCLC cell nude mouse xenografts, possibly through microvessel density reduction. Future clinical trials are needed to confirm the findings of this study. PMID:27852073
den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R
1994-06-01
Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.
Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K
2006-07-21
In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.
Isanaka, Sheila; Mugusi, Ferdinand; Hawkins, Claudia; Spiegelman, Donna; Okuma, James; Aboud, Said; Guerino, Chalamilla; Fawzi, Wafaie W.
2013-01-01
Context Large randomized trials have previously shown that high-dose micronutrient supplementation can increase CD4 counts and reduce human immunodeficiency virus (HIV) disease progression and mortality among individuals not receiving highly active antiretroviral therapy (HAART); however, the safety and efficacy of such supplementation has not been established in the context of HAART. Objective To test the hypothesis that high-dose multivitamin supplementation vs standard-dose multivitamin supplementation decreases the risk of HIV disease progression or death and improves immunological, virological, and nutritional parameters in patients with HIV initiating HAART. Design, Setting, and Participants A randomized, double-blind, controlled trial of high-dose vs standard-dose multivitamin supplementation for 24 months in 3418 patients with HIV initiating HAART between November 2006 and November 2008 in 7 clinics in Dar es Salaam, Tanzania. Intervention The provision of daily oral supplements of vitamin B complex, vitamin C, and vitamin E at high levels or standard levels of the recommended dietary allowance. Main Outcome Measure The composite of HIV disease progression or death from any cause. Results The study was stopped early in March 2009 because of evidence of increased levels of alanine transaminase (ALT) in patients receiving the high-dose multivitamin supplement. At the time of stopping, 3418 patients were enrolled (median follow-up, 15 months), and there were 2374 HIV disease progression events and 453 observed deaths (2460 total combined events). Compared with standard-dose multivitamin supplementation, high-dose supplementation did not reduce the risk of HIV disease progression or death. The absolute risk of HIV progression or death was 72% in the high-dose group vs 72% in the standard-dose group (risk ratio [RR], 1.00; 95% CI, 0.96–1.04). High-dose supplementation had no effect on CD4 count, plasma viral load, body mass index, or hemoglobin level concentration, but increased the risk of ALT elevations (1239 events per 1215 person-years vs 879 events per 1236 person-years; RR, 1.44; 95% CI, 1.11–1.87) vs standard-dose supplementation. Conclusion In adults receiving HAART, use of high-dose multivitamin supplements compared with standard-dose multivitamin supplements did not result in a decrease in HIV disease progression or death but may have resulted in an increase in ALT levels. Trial Registration clinicaltrials.gov Identifier: NCT00383669 PMID:23073950
Oxytocin regimen for labor augmentation, labor progression, and perinatal outcomes.
Zhang, Jun; Branch, D Ware; Ramirez, Mildred M; Laughon, S Katherine; Reddy, Uma; Hoffman, Mathew; Bailit, Jennifer; Kominiarek, Michelle; Chen, Zhen; Hibbard, Judith U
2011-08-01
To examine the effects and safety of high-dose (compared with low-dose) oxytocin regimen for labor augmentation on perinatal outcomes. Data from the Consortium on Safe Labor were used. A total of 15,054 women from six hospitals were eligible for the analysis. Women were grouped based on their oxytocin starting dose and incremental dosing of 1, 2, and 4 milliunits/min. Duration of labor and a number of maternal and neonatal outcomes were compared among these three groups stratified by parity. Multivariable logistic regression and generalized linear mixed model were used to adjust for potential confounders. Oxytocin regimen did not affect the rate of cesarean delivery or other perinatal outcomes. Compared with 1 milliunit/min, the regimens starting with 2 milliunits/min and 4 milliunits/min reduced the duration of first stage by 0.8 hours (95% confidence interval 0.5-1.1) and 1.3 hours (1.0-1.7), respectively, in nulliparous women. No effect was observed on the second stage of labor. Similar patterns were observed in multiparous women. High-dose regimen was associated with a reduced risk of meconium stain, chorioamnionitis, and newborn fever in multiparous women. High-dose oxytocin regimen (starting dose at 4 milliunits/min and increment of 4 millliunits/min) is associated with a shorter duration of first-stage of labor for all parities without increasing the cesarean delivery rate or adversely affecting perinatal outcomes. II.
Efficacy of short-term moderate or high-dose rosuvastatin in preventing contrast-induced nephropathy
Liang, Min; Yang, Shicheng; Fu, Naikuan
2017-01-01
Abstract Background: The prophylactic efficacy of statin pretreatment for the prevention of contrast-induced nephropathy (CIN) in patients undergoing coronary angiography (CAG) or percutaneous coronary intervention (PCI) remains controversial. The aim of the study was to perform a meta-analysis of randomized controlled trials (RCTs) to assess the effectiveness of short-term moderate or high-dose rosuvastatin pretreatment in preventing CIN. Methods: We included RCTs comparing short-term moderate or high-dose rosuvastatin treatment versus low-dose rosuvastatin treatment or placebo for preventing CIN. The primary endpoint was the incidence of CIN within 2 to 5 days after contrast administration, and related-parameters including serum creatinine (SCr), cystatin C (CysC), hypersensitive C-reactive protein (hs-CRP), urine microalbumin (mALB) were also extracted. Results: Fifteen RCTs with a total of 2673 patients were identified and analyzed. Patients who received moderate or high-dose rosuvastatin pretreatment had a 55% lower risk of CIN compared with low-dose rosuvastatin pretreatment or placebo group based on a fixed effect model (RR = 0.45, 95% CI 0.35–0.58, P < .0001). The benefit of moderate or high-dose rosuvastatin was consistent in both comparisons with low-dose rosuvastatin (RR = 0.40, 95% CI 0.27–0.59, P < .0001) or placebo (RR = 0.45, 95% CI 0.35–0.58, P < .0001). And moderate (20 mg) or high dose (≥40 mg) rosuvastatin significantly reduced the incidence of CIN compared with the control (RR = 0.39, 95% CI 0.29–0.54, P < .0001, RR = 0.56, 95% CI 0.37–0.85, P = .006, respectively). Subgroup analysis showed that moderate or high-dose rosuvastatin pretreatment could decrease the incidence of CIN in patients with chronic kidney disease (CKD) (RR = 0.53, 95% CI 0.30–0.93, P = .03) or diabetes mellitus (DM) (RR = 0.51, 95% CI 0.31–0.86, P = .01) or acute coronary syndrome (ACS) patients undergoing PCI (RR = 0.52, 95% CI 0.35–0.76, P = .0009) or in studies which received mean contrast volume ≥110 mL (RR = 0.43, 95% CI 0.32–0.58, P < .0001). The SCr, CysC, hs-CRP, and mALB after the operation in the moderate or high-dose rosuvastatin group were lower than those of low-dose rosuvastatin group. Conclusion: This meta-analysis demonstrated that moderate or high-dose rosuvastatin treatment could reduce the incidence of CIN in patients undergoing CAG or PCI. Moreover, moderate or high-dose rosuvastatin would be beneficial in high-risk patients with CKD or DM or undergoing PCI. PMID:28682890
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diez, Patricia; Vogelius, Ivan S.; Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792
2010-07-15
Purpose: A new method is presented for synthesizing dose-response data for biochemical control of prostate cancer according to study design (randomized vs. nonrandomized) and risk group (low vs. intermediate-high). Methods and Materials: Nine published prostate cancer dose escalation studies including 6,539 patients were identified in the MEDLINE and CINAHL databases and reviewed to assess the relationship between dose and biochemical control. A novel method of analysis is presented in which the normalized dose-response gradient, {gamma}{sub 50}, is estimated for each study and subsequently synthesized across studies. Our method does not assume that biochemical control rates are directly comparable between studies.more » Results: Nonrandomized studies produced a statistically significantly higher {gamma}{sub 50} than randomized studies for intermediate- to high-risk patients ({gamma}{sub 50} = 1.63 vs. {gamma}{sub 50} = 0.93, p = 0.03) and a borderline significantly higher ({gamma}{sub 50} = 1.78 vs. {gamma}{sub 50} = 0.56, p = 0.08) for low-risk patients. No statistically significant difference in {gamma}{sub 50} was found between low- and intermediate- to high-risk patients (p = 0.31). From the pooled data of low and intermediate- to high-risk patients in randomized trials, we obtain the overall best estimate of {gamma}{sub 50} = 0.84 with 95% confidence interval 0.54-1.15. Conclusions: Nonrandomized studies overestimate the steepness of the dose-response curve as compared with randomized trials. This is probably the result of stage migration, improved treatment techniques, and a shorter follow-up in higher dose patients that were typically entered more recently. This overestimation leads to inflated expectations regarding the benefit from dose-escalation and could lead to underpowered clinical trials. There is no evidence of a steeper dose response for intermediate- to high-risk compared with low-risk patients.« less
Qayyum, Rehan; Becker, Diane M.; Yanek, Lisa R.; Moy, Taryn F.; Becker, Lewis C.; Faraday, Nauder; Vaidya, Dhananjay
2011-01-01
Compared to men, women have greater platelet aggregation before and after low-dose aspirin. It is not known whether high-dose aspirin therapy brings residual platelet aggregation in women closer to men. Our objective was to compare the inhibition of platelet aggregation in women and men after low and high-dose aspirin. We enrolled healthy subjects (N=106) in a trial of 14 days of aspirin 81 mg/day followed by 14 days of 325 mg/day. Platelet function was measured at baseline and following both aspirin doses. Women had greater baseline platelet activation measures. After both aspirin doses, both sexes had near complete suppression of platelet aggregation to arachidonic acid in whole blood and in platelet-rich plasma (PRP), the direct cyclooxygenase-1 (COX-1) pathway affected by aspirin. For indirect pathways, women had significantly greater residual platelet activation to collagen and adenosine diphosphate (ADP) in whole blood after both aspirin doses and in response to collagen and ADP in PRP after aspirin 325 mg/day only. After aspirin 325 mg/day, women continued to have greater residual platelet aggregation compared to men after aspirin 81 mg/day in response to collagen (p=0.016 in whole blood and p=0.037 in PRP), ADP (p<0.001 in whole blood and p=0.012 in PRP), and epinephrine (p=0.03 in PRP). Excretion of urinary thromboxane metabolite (urinary 11-dehydro thromboxane B2) decreased after aspirin to a similar extent in both sexes. In conclusion, women continue to have greater residual platelet activity after high-dose aspirin even when compared to men treated with a lower dose of aspirin. PMID:18435972
Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P
2018-02-01
The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Eun-Jung, E-mail: forejs2@yuhs.ac; Kim, Jun Won, E-mail: JUNWON@yuhs.ac; Yoo, Hyun, E-mail: gochunghee@yuhs.ac
We have revealed in a porcine skin injury model that eosinophil recruitment was dose-dependently enhanced by a single high-dose irradiation. In this study, we investigated the underlying mechanism of eosinophil-associated skin fibrosis and the effect of high-dose-per-fraction radiation. The dorsal skin of a mini-pig was divided into two sections containing 4-cm{sup 2} fields that were irradiated with 30 Gy in a single fraction or 5 fractions and biopsied regularly over 14 weeks. Eosinophil-related Th2 cytokines such as interleukin (IL)-4, IL-5, and C–C motif chemokine-11 (CCL11/eotaxin) were evaluated by quantitative real-time PCR. RNA-sequencing using 30 Gy-irradiated mouse skin and functional assays in amore » co-culture system of THP-1 and irradiated-human umbilical vein endothelial cells (HUVECs) were performed to investigate the mechanism of eosinophil-mediated radiation fibrosis. Single high-dose-per-fraction irradiation caused pronounced eosinophil accumulation, increased profibrotic factors collagen and transforming growth factor-β, enhanced production of eosinophil-related cytokines including IL-4, IL-5, CCL11, IL-13, and IL-33, and reduced vessels compared with 5-fraction irradiation. IL-33 notably increased in pig and mouse skin vessels after single high-dose irradiation of 30 Gy, as well as in irradiated HUVECs following 12 Gy. Blocking IL-33 suppressed the migration ability of THP-1 cells and cytokine secretion in a co-culture system of THP-1 cells and irradiated HUVECs. Hence, high-dose-per-fraction irradiation appears to enhance eosinophil-mediated fibrotic responses, and IL-33 may be a key molecule operating in eosinophil-mediated fibrosis in high-dose-per fraction irradiated skin. - Highlights: • Single high-dose irradiation aggravates eosinophil-mediated fibrosis through IL-33. • Vascular endothelial cells damaged by high-dose radiation secrete IL-33. • Blocking IL-33 suppressed migration of inflammatory cells and cytokine secretion. • IL-33 is a key in eosinophil-mediated fibrosis in high-dose-per-fraction radiation.« less
Dornelles, Laura Vargas; Corso, Andréa Lúcia; Silveira, Rita de Cássia; Procianoy, Renato Soibelmann
2016-01-01
To compare the efficacy of intravenous ibuprofen at high (20-10-10mg/kg/dose) and low doses (10-5-5mg/kg/dose) the closure of patent ductus arteriosus in preterm newborns. A cohort study with historical control of newborns that received high- and low-dose intravenous ibuprofen, from 2010 to 2013 in a neonatal intensive care unit, for closure of the patent ductus arteriosus, documented by echocardiography. Secondary outcomes included the number of ibuprofen cycles, incidence of bronchopulmonary dysplasia, necrotizing enterocolitis, changes in renal function, and death. Seventy-seven patients received three doses of ibuprofen for the treatment of patent ductus arteriosus, with 33 receiving high-dose and 44 low-dose therapy. The ductus closed after the first cycle in 25 (56.8%) low-dose patients and in 17 (51.5%) high-dose patients (p>0.99). Sixteen patients received a second cycle of ibuprofen, and the ductus closed in 50% after low-dose and in 60% after high-dose therapy (p>0.99). Seven patients required surgery for ductus closure, 13.6% in the low-dose group and 3% in the high-dose group (p=0.22). Thirty-nine patients developed bronchopulmonary dysplasia, 50% in the low-dose group and 51.5% in the high-dose group (p>0.99). Twenty-two (50%) low-dose patients died vs. 15 (45.5%) high-dose patients (p=0.86). There was no difference in closure of the ductus arteriosus or occurrence of adverse effects between the two dose regimens. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Effect of Qingnao tablet on blood viscosity of rat model of blood stasis induced by epinephrine
NASA Astrophysics Data System (ADS)
Xie, Guoqi; Hao, Shaojun; Ma, Zhenzhen; Liu, Xiaobin; Li, Jun; Li, Wenjun; Zhang, Zhengchen
2018-04-01
To establish a rat model of blood stasis with adrenaline (Adr) subcutaneous injection and ice bath stimulation. The effects of different doses on the blood viscosity of blood stasis model rats were observed. The rats were randomly divided into 6 groups: blank control group (no model), model group, positive control group, high, middle and low dose group. The whole blood viscosity and plasma viscosity were detected by blood viscosity instrument. Compared with the blank group, model group, high shear, low shear whole blood viscosity and plasma viscosity were significantly increased, TT PT significantly shortened, APTT was significantly prolonged, FIB increased significantly, indicating that the model was successful. Compared with the model group, can significantly reduce the Naoluotong group (cut, low cut). Qingnaopian high dose group (low cut), middle dose group (cut, low shear blood viscosity) (P<0.01), Can significantly reduce Naoluotong qingnaopian group, high dose group (P<0.01), plasma viscosity decreased qingnaopian plasma viscosity in low dose group (P<0.05). Conclusion: qingnaopian could improve the blood rheology of blood stasis mice abnormal index, decrease the blood viscosity, blood stasis has certain hemostatic effect.
NASA Astrophysics Data System (ADS)
McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.
2017-08-01
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.
McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A; Purdie, Thomas G
2017-07-06
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.
Simultaneous integrated vs. sequential boost in VMAT radiotherapy of high-grade gliomas.
Farzin, Mostafa; Molls, Michael; Astner, Sabrina; Rondak, Ina-Christine; Oechsner, Markus
2015-12-01
In 20 patients with high-grade gliomas, we compared two methods of planning for volumetric-modulated arc therapy (VMAT): simultaneous integrated boost (SIB) vs. sequential boost (SEB). The investigation focused on the analysis of dose distributions in the target volumes and the organs at risk (OARs). After contouring the target volumes [planning target volumes (PTVs) and boost volumes (BVs)] and OARs, SIB planning and SEB planning were performed. The SEB method consisted of two plans: in the first plan the PTV received 50 Gy in 25 fractions with a 2-Gy dose per fraction. In the second plan the BV received 10 Gy in 5 fractions with a dose per fraction of 2 Gy. The doses of both plans were summed up to show the total doses delivered. In the SIB method the PTV received 54 Gy in 30 fractions with a dose per fraction of 1.8 Gy, while the BV received 60 Gy in the same fraction number but with a dose per fraction of 2 Gy. All of the OARs showed higher doses (Dmax and Dmean) in the SEB method when compared with the SIB technique. The differences between the two methods were statistically significant in almost all of the OARs. Analysing the total doses of the target volumes we found dose distributions with similar homogeneities and comparable total doses. Our analysis shows that the SIB method offers advantages over the SEB method in terms of sparing OARs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uehara, R; Tachibana, H
Purpose: There have been several publications focusing on dose calculation in lung for a new dose calculation algorithm of Acuros XB (AXB). AXB could contribute to dose calculation for high-density media for bone and dental prosthesis rather than in lung. We compared the dosimetric performance of AXB, Adaptive Convolve (AC) in head and neck IMRT plans. Methods: In a phantom study, the difference in depth profile between AXB and AC was evaluated using Kodak EDR2 film sandwiched with tough water phantoms. 6 MV x-ray using the TrueBeam was irradiated. In a patient study, 20 head and neck IMRT plans hadmore » been clinically approved in Pinnacle3 and were transferred to Eclipse. Dose distribution was recalculated using AXB in Eclipse while maintaining AC-calculated monitor units and MLC sequence planned in Pinnacle. Subsequently, both the dose-volumetric data obtained using the two different calculation algorithms were compared. Results: The results in the phantom evaluation for the shallow area ahead of the build-up region shows over-dose for AXB and under-dose for AC, respectively. In the patient plans, AXB shows more hot spots especially around the high-density media than AC in terms of PTV (Max difference: 4.0%) and OAR (Max. difference: 1.9%). Compared to AC, there were larger dose deviations in steep dose gradient region and higher skin-dose. Conclusion: In head and neck IMRT plans, AXB and AC show different dosimetric performance for the regions inside the target volume around high-density media, steep dose gradient regions and skin-surface. There are limitations in skin-dose and complex anatomic condition using even inhomogeneous anthropomorphic phantom Thus, there is the potential for an increase of hot-spot in AXB, and an underestimation of dose in substance boundaries and skin regions in AC.« less
High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death.
Ray, Wayne A; Chung, Cecilia P; Murray, Katherine T; Hall, Kathi; Stein, C Michael
2017-02-01
Studies demonstrating that higher doses of citalopram (> 40 mg) and escitalopram (> 20 mg) prolong the corrected QT interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these selective serotonin reuptake inhibitors (SSRIs) to that for equivalent doses of fluoxetine, paroxetine, and sertraline. The Tennessee Medicaid retrospective cohort study included 54,220 persons 30-74 years of age without cancer or other life-threatening illness who were prescribed high-dose SSRIs from 1998 through 2011. The mean age was 47 years, and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of proarrhythmic effects. The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% CI, 0.40-1.75), 1.24 (95% CI, 0.75-2.05), 0.75 (95% CI, 0.45-1.24), and 1.53 (95% CI, 0.91-2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥ 60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study end point. We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. © Copyright 2016 Physicians Postgraduate Press, Inc.
High-Dose Citalopram and Escitalopram and the Risk of Out-of-Hospital Death
Ray, Wayne A.; Chung, Cecilia P.; Murray, Katherine T.; Hall, Kathi; Stein, C. Michael
2018-01-01
Objective Studies demonstrating higher doses of citalopram (>40mg) and escitalopram (>20mg) prolong the QTc interval prompted regulatory agency warnings, which are controversial, given the absence of confirmatory clinical outcome studies. We compared the risk of potential arrhythmia-related deaths for high doses of these SSRIs to that for equivalent doses of fluoxetine, paroxetine, and sertraline. Method The Tennessee Medicaid retrospective cohort study included 54,220 persons 30–74 years of age without cancer or other life-threatening illness prescribed high-dose SSRIs. The mean age was 47 years and 76% were female. Demographic characteristics and comorbidity for individual SSRIs were comparable. Because arrhythmia-related deaths are typically sudden and occur outside the hospital, we analyzed out-of-hospital sudden unexpected death as well as sudden cardiac deaths, a more specific indicator of pro-arrhythmic effects. Results The adjusted risk of sudden unexpected death for citalopram did not differ significantly from that for the other SSRIs. The respective hazard ratios (HRs) for citalopram versus escitalopram, fluoxetine, paroxetine, and sertraline were 0.84 (95% confidence interval [CI], 0.40–1.75), 1.24 (0.75–2.05), 0.75 (0.45–1.24), and 1.53 (0.91–2.55). There were no significant differences for sudden cardiac death or all study deaths, nor were there significant differences among high-risk patients (≥60 years of age, upper quartile baseline cardiovascular risk). Escitalopram users had no significantly increased risk for any study endpoint. Conclusions We found no evidence that risk of sudden unexpected death, sudden cardiac death, or total mortality for high-dose citalopram and escitalopram differed significantly from that for comparable doses of fluoxetine, paroxetine, and sertraline. PMID:27736049
Local noise reduction for emphysema scoring in low-dose CT images
NASA Astrophysics Data System (ADS)
Schilham, Arnold; Prokop, Mathias; Gietema, Hester; van Ginneken, Bram
2005-04-01
Computed Tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure for emphysema derived from CT is the Pixel Index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on intensity, this measure is strongly influenced by noise. This effect shows up clearly when comparing the PI score for a high-dose scan to the PI score for a low-dose (i.e. noisy) scan of the same subject. This paper presents a class of noise filters that make use of a local noise estimate to specify the filtering strength: Local Noise Variance Weighted Averaging (LNVWA). The performance of the filter is assessed by comparing high-dose and low-dose PI scores for 11 subjects. LNVWA improves the reproducibility of high-dose PI scores: For an emphysema threshold of -910 HU, the root-mean-square difference in PI score drops from 10% of the lung volume to 3.3% of the lung volume if LNVWA is used.
Auger, R Robert; Goodman, Scott H; Silber, Michael H; Krahn, Lois E; Pankratz, V Shane; Slocumb, Nancy L
2005-06-01
To ascertain complications associated with high-dose stimulant therapy in patients with narcolepsy or idiopathic hypersomnia. Case-control, retrospective chart review. Sleep center in an academic hospital. 116 patients with narcolepsy or idiopathic hypersomnia were individually matched by sex, diagnosis, age of onset, and duration of follow-up from both onset and diagnosis. Members of the high-dose group (n = 58) had received at least 1 stimulant at a dosage > or = 120% of the maximum recommended by the American Academy of Sleep Medicine Standards of Practice Committee. The standard-dose control group (n = 58) had received stimulants at a dosage < or = 100% of the American Academy of Sleep Medicine guidelines. N/A. The prevalence of psychosis (odds ratio = 12.0 [1.6-92.0]), alcohol or polysubstance misuse (odds ratio = 4.3 [1.2-15.2]), and psychiatric hospitalization (odds ratio = 3.2 [1.1-10.0]) was significantly increased in the high-dose group. More high-dose patients also experienced tachyarrhythmias (odds ratio = 3.3 [0.92-12.1] and anorexia or weight loss (odds ratio = 11.0 [1.4-85.2]). The frequency of physician-diagnosed depression, drug-seeking and suicide-related behaviors, hypertension, and cardiovascular disease did not differ significantly between the groups. This study demonstrated a significantly higher occurrence of psychosis, substance misuse, and psychiatric hospitalizations in patients using high-dose stimulants compared to those using standard doses. Tachyarrhythmias and anorexia or weight loss were also more common in this group as compared with controls. Clinicians should be very cautious in prescribing dosages that exceed maximum guidelines.
Kanto, Kousei; Ito, Hiroyuki; Noso, Shinsuke; Babaya, Naru; Hiromine, Yoshihisa; Taketomo, Yasunori; Toma, Junko; Niwano, Fumimaru; Yasutake, Sara; Kawabata, Yumiko; Ikegami, Hiroshi
2017-09-30
Differences in the efficacy and safety of antidiabetic drugs among different ethnic groups are well documented. Metformin is widely used in the treatment of type 2 diabetes in Western countries, but high doses of metformin have been approved only recently for clinical use in Japan. The aim of the present study was to investigate the effects of dosage and dosing frequency on the efficacy and safety of high-dose metformin in Japanese patients. A total of 71 Japanese patients with type 2 diabetes were prospectively studied for the effects of dosage and dosing frequency on the efficacy and safety of metformin during hospitalization. Dose effects were studied in 27 patients treated with 0, 500, 1,000, 1,500 and 2,250 mg/day of metformin. The effect of dosing frequency was compared in 56 patients with 1,500 mg/day of metformin administered either two or three times per day. Significant dose-dependent improvement in daily profiles of blood glucose was observed with metformin dosages up to 1,500 mg/day, with a trend towards further improvement observed at 2,250 mg/day. The efficacy of 1,500 mg of metformin was comparable when the drug was administered either two or three times per day. The most frequently reported side-effects were gastrointestinal symptoms, which were not affected by the dosage or dosing frequency of metformin. These results show that the efficacy of high-dose metformin is dose-dependent in Japanese patients. The efficacy and safety of metformin were similar when the drug was administered either two or three times per day. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woods, K; Tran, A; Yu, V
Purpose: Thinning of the cerebral cortex has been observed in patients treated with fractionated partial brain radiation therapy and may contribute to cognitive decline following treatment. The extent of this thinning is dose-dependent, and was shown comparable to that of neurodegenerative diseases such as Alzheimer’s disease at one year post-therapy. This study investigates whether 4π radiotherapy can enable better sparing of the cortex and other critical structures when compared to conventional clinical IMRT plans. Methods: Clinical cortex-sparing IMRT plans for 15 high-grade glioma patients were included in this study. 4π radiotherapy plans were created for each patient with 20 intensity-modulatedmore » non-coplanar fields selected with a greedy column-generation optimization. All plans were normalized to deliver 100% of the prescribed dose to 95% of the planning target volume (PTV). The mean and maximum dose to the cerebral cortex and other organs at risk (OARs) were compared for the two plan types, as well as the conformity index (CI), homogeneity index (HI), and 50% dose spillage volume (R50). Results: The 4π plans significantly reduced the mean cortex dose by an average of 16% (range 6% to 27%) compared to the clinical plans. The mean dose to every other OAR compared was also reduced by 15% to 43%, with statistically significant reductions to the brainstem, chiasm, eyes, optic nerves, subcortical whit, and hippocampus. The average maximum doses were also reduced for 10/12 OARs. The R50 was significantly reduced with the 4π plans (>14%) and the homogeneity index was significantly improved. Conclusion: 4π enables significant sparing of the cerebral cortex when treating high-grade gliomas with fractionated partial brain radiation therapy, potentially reducing the risk of harmful dose-dependent cortical thinning. NIH R43CA183390, NIH R01CA188300, Varian Medical Systems.« less
LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.
King, Christopher R
2002-01-01
Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (<70 Gy), but similar to results from dose escalation series. LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy using current dose regimens. However, HDR brachytherapy dose escalation regimens might be able to achieve higher biologically effective doses of irradiation in comparison to LDR, and hence improved outcomes. This advantage over LDR would be amplified should prostate cancer possess a high sensitivity to dose fractionation (i.e., a low alpha/beta ratio) as the current evidence suggests.
High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses
ERIC Educational Resources Information Center
Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.
2007-01-01
Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…
Richards, Stephanie L; Anderson, Sheri L; Lord, Cynthia C; Tabachnick, Walter J
2012-11-01
Culex nigripalpus Theobald is a primary vector of St. Louis encephalitis virus in the southeastern United States. Cx. nigripalpus females were fed blood containing a low (4.0 +/- 0.01 log10 plaque-forming unit equivalents (PFUeq) /ml) or high (4.7 +/- 0.1 log10 PFUeq/ml) St. Louis encephalitis virus dose and maintained at extrinsic incubation temperatures (EIT) of 25 or 28 degrees C for 12 d. Vector competence was measured via quantitative real-time reverse transcriptase polymerase chain reaction to estimate PFUeq using rates of infection, dissemination, and transmission. There were no differences in infection rates between the two EITs at either dose. The low dose had higher infection rates at both EITs. Dissemination rates were significantly higher at 28 degrees C compared with 25 degrees C at both doses. Virus transmission was observed (<7%) only at 28 degrees C for both doses. The virus titer in body tissues was greater at 28 degrees C compared with 25 degrees C at both doses. The difference between the EITs was greater at the low dose, resulting in a higher titer for the low dose than the high dose at 28 degrees C. Virus titers in leg tissues were greater in mosquitoes fed the high versus low dose, but were not influenced by EIT. Further investigations using a variety of environmental and biological factors would be useful in exploring the complexity of vector competence.
RICHARDS, STEPHANIE L.; ANDERSON, SHERI L.; LORD, CYNTHIA C.; TABACHNICK, WALTER J.
2013-01-01
Culex nigripalpus Theobald is a primary vector of St. Louis encephalitis virus in the southeastern United States. Cx. nigripalpus females were fed blood containing a low (4.0 ± 0.01 log10 plaque-forming unit equivalents (PFUeq)/ml) or high (4.7 ± 0.1 log10 PFUeq/ml) St. Louis encephalitis virus dose and maintained at extrinsic incubation temperatures (EIT) of 25 or 28°C for 12 d. Vector competence was measured via quantitative real-time reverse transcriptase polymerase chain reaction to estimate PFUeq using rates of infection, dissemination, and transmission. There were no differences in infection rates between the two EITs at either dose. The low dose had higher infection rates at both EITs. Dissemination rates were significantly higher at 28°C compared with 25°C at both doses. Virus transmission was observed (<7%) only at 28°C for both doses. The virus titer in body tissues was greater at 28°C compared with 25°C at both doses. The difference between the EITs was greater at the low dose, resulting in a higher titer for the low dose than the high dose at 28°C. Virus titers in leg tissues were greater in mosquitoes fed the high versus low dose, but were not influenced by EIT. Further investigations using a variety of environmental and biological factors would be useful in exploring the complexity of vector competence. PMID:23270182
Effects of dietary methylmercury on juvenile Sacramento blackfish bioenergetics.
Houck, Ann; Cech, Joseph J
2004-08-10
Although much is known about the biogeochemical cycling of mercury in the environment, relatively little is known about methylmercury (MeHg) bioaccumulation in fishes and how chronic sub-lethal exposures affect their functioning. Several species of fish in Clear Lake, California have high MeHg tissue levels, including Sacramento blackfish, Orthodon microlepidotus, a large native cyprinid that is fished commercially. We fed juvenile blackfish one of four diets containing MeHg (0.21 mg/kg control; 0.52 mg/kg low; 22.2 mg/kg medium; and 55.5 mg/kg high treatments) for 70 days. There were no statistical differences (P > 0.05) in food consumption among the treatment groups. By 35 days the high treatment group had a significantly depressed growth rate when compared to the control group (P < 0.05) and by 70 days both the medium and the high groups had significantly lower growth rates (P < 0.05). The high-dose group had a significantly (P < 0.05) lower specific growth rate (SGR) compared all other treatment groups at 35 days, although by 70 days these differences were not significant. The wet/dry muscle mass and muscle mass/total mass ratios, condition factor, and resting routine metabolic rates at both 35 and 70 days were statistically indistinguishable (P > 0.05) between treatment groups. All treatment groups assimilated the dietary MeHg into muscle tissue in a dose-dependent fashion. Percent assimilation was significantly lower (P < 0.05) in the high-dose group compared to the low-dose group at 35 days, (control 53%, low-dose 61%, medium-dose 50%, and high-dose 40%) but at 70 days assimilation was lower (35, 43, 42, and 32%, respectively) and statistically indistinguishable (P > 0.05) among the treatment groups. Dietary MeHg concentrations and bioaccumulation rates were correlated (r2 = 0.98 at 35 days, 0.99 at 70 days). These results may contribute to construction of ecosystem mercury models and more informed natural resources management at Clear Lake.
NASA Astrophysics Data System (ADS)
Kinhikar, Rajesh A.; Sharma, Pramod K.; Tambe, Chandrashekhar M.; Mahantshetty, Umesh M.; Sarin, Rajiv; Deshpande, Deepak D.; Shrivastava, Shyam K.
2006-07-01
In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose™ in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.
High-dose MVCT image guidance for stereotactic body radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westerly, David C.; Schefter, Tracey E.; Kavanagh, Brian D.
Purpose: Stereotactic body radiation therapy (SBRT) is a potent treatment for early stage primary and limited metastatic disease. Accurate tumor localization is essential to administer SBRT safely and effectively. Tomotherapy combines helical IMRT with onboard megavoltage CT (MVCT) imaging and is well suited for SBRT; however, MVCT results in reduced soft tissue contrast and increased image noise compared with kilovoltage CT. The goal of this work was to investigate the use of increased imaging doses on a clinical tomotherapy machine to improve image quality for SBRT image guidance. Methods: Two nonstandard, high-dose imaging modes were created on a tomotherapy machinemore » by increasing the linear accelerator (LINAC) pulse rate from the nominal setting of 80 Hz, to 160 Hz and 300 Hz, respectively. Weighted CT dose indexes (wCTDIs) were measured for the standard, medium, and high-dose modes in a 30 cm solid water phantom using a calibrated A1SL ion chamber. Image quality was assessed from scans of a customized image quality phantom. Metrics evaluated include: contrast-to-noise ratios (CNRs), high-contrast spatial resolution, image uniformity, and percent image noise. In addition, two patients receiving SBRT were localized using high-dose MVCT scans. Raw detector data collected after each scan were used to reconstruct standard-dose images for comparison. Results: MVCT scans acquired using a pitch of 1.0 resulted in wCTDI values of 2.2, 4.7, and 8.5 cGy for the standard, medium, and high-dose modes respectively. CNR values for both low and high-contrast materials were found to increase with the square root of dose. Axial high-contrast spatial resolution was comparable for all imaging modes at 0.5 lp/mm. Image uniformity was improved and percent noise decreased as the imaging dose increased. Similar improvements in image quality were observed in patient images, with decreases in image noise being the most notable. Conclusions: High-dose imaging modes are made possible on a clinical tomotherapy machine by increasing the LINAC pulse rate. Increasing the imaging dose results in increased CNRs; making it easier to distinguish the boundaries of low contrast objects. The imaging dose levels observed in this work are considered acceptable at our institution for SBRT treatments delivered in 3-5 fractions.« less
High-dose MVCT image guidance for stereotactic body radiation therapy.
Westerly, David C; Schefter, Tracey E; Kavanagh, Brian D; Chao, Edward; Lucas, Dan; Flynn, Ryan T; Miften, Moyed
2012-08-01
Stereotactic body radiation therapy (SBRT) is a potent treatment for early stage primary and limited metastatic disease. Accurate tumor localization is essential to administer SBRT safely and effectively. Tomotherapy combines helical IMRT with onboard megavoltage CT (MVCT) imaging and is well suited for SBRT; however, MVCT results in reduced soft tissue contrast and increased image noise compared with kilovoltage CT. The goal of this work was to investigate the use of increased imaging doses on a clinical tomotherapy machine to improve image quality for SBRT image guidance. Two nonstandard, high-dose imaging modes were created on a tomotherapy machine by increasing the linear accelerator (LINAC) pulse rate from the nominal setting of 80 Hz, to 160 Hz and 300 Hz, respectively. Weighted CT dose indexes (wCTDIs) were measured for the standard, medium, and high-dose modes in a 30 cm solid water phantom using a calibrated A1SL ion chamber. Image quality was assessed from scans of a customized image quality phantom. Metrics evaluated include: contrast-to-noise ratios (CNRs), high-contrast spatial resolution, image uniformity, and percent image noise. In addition, two patients receiving SBRT were localized using high-dose MVCT scans. Raw detector data collected after each scan were used to reconstruct standard-dose images for comparison. MVCT scans acquired using a pitch of 1.0 resulted in wCTDI values of 2.2, 4.7, and 8.5 cGy for the standard, medium, and high-dose modes respectively. CNR values for both low and high-contrast materials were found to increase with the square root of dose. Axial high-contrast spatial resolution was comparable for all imaging modes at 0.5 lp∕mm. Image uniformity was improved and percent noise decreased as the imaging dose increased. Similar improvements in image quality were observed in patient images, with decreases in image noise being the most notable. High-dose imaging modes are made possible on a clinical tomotherapy machine by increasing the LINAC pulse rate. Increasing the imaging dose results in increased CNRs; making it easier to distinguish the boundaries of low contrast objects. The imaging dose levels observed in this work are considered acceptable at our institution for SBRT treatments delivered in 3-5 fractions.
Jensen, Rikke Beck; Thankamony, Ajay; O'Connell, Susan M; Kirk, Jeremy; Donaldson, Malcolm; Ivarsson, Sten-A; Söder, Olle; Roche, Edna; Hoey, Hilary; Dunger, David B; Juul, Anders
2014-10-01
Short children born small for gestational age (SGA) are treated with a GH dose based on body size, but treatment may lead to high levels of IGF1. The objective was to evaluate IGF1 titration of GH dose in contrast to current dosing strategies. In the North European Small-for-Gestational-Age Study (NESGAS), 92 short pre-pubertal children born SGA were randomised after 1 year of high-dose GH treatment (67 μg/kg per day) to three different regimens: high dose (67 μg/kg per day), low dose (35 μg/kg per day) or IGF1 titration. The average dose during the second year of the randomised trial did not differ between the IGF1 titration group (38 μg/kg per day, s.d. 0.019) and the low-dose group (35 μg/kg per day, s.d. 0.002; P=0.46), but there was a wide variation in the IGF1 titration group (range 10-80 μg/kg per day). The IGF1 titration group had significantly lower height gain (0.17 SDS, s.d. 0.18) during the second year of the randomised trial compared with the high-dose group (0.46 SDS, s.d. 0.25), but not significantly lower than the low-dose group (0.23 SDS, s.d. 0.15; P=0.17). The IGF1 titration group had lower IGF1 levels after 2 years of the trial (mean 1.16, s.d. 1.24) compared with both the low-dose (mean 1.76, s.d. 1.48) and the high-dose (mean 2.97, s.d. 1.63) groups. IGF1 titration of GH dose in SGA children proved less effective than current dosing strategies. IGF1 titration resulted in physiological IGF1 levels with a wide range of GH dose and a poorer growth response, which indicates the role of IGF1 resistance and highlights the heterogeneity of short SGA children. © 2014 European Society of Endocrinology.
Use of high-dose nandrolone aggravates septic shock in a mouse model.
Lin, Che; Chen, Shou-Tung; Chien, Su-Yu; Kuo, Shou-Jen; Chen, Dar-Ren
2011-06-01
Nandrolone, an anabolic-androgenic steroid, is widely misused by athletes who wish to rapidly increase muscle mass and performance. An increasing number of reports have indicated that nandrolone may affect and modulate the immune system. This study aimed to investigate the effects of nandrolone on septic shock-caused immune responses and the cellular mechanism of action using a sepsis murine model. Before septic shock induction, BALB/c mice were given a high dose of nandrolone or peanut oil only. After septic shock induction, mice were sacrificed at different time points. Their blood and tissue specimens were analyzed. It was found that the high-dose nandrolone group had significantly increased mortality compared with the control group (p<0.001). The serum malondialdehyde level was significantly increased in the high-dose group compared with the control group. Animals administered a high dose of nandrolone had significantly increased hepatic tumor necrosis factor-α or splenic interferon-γ at 0 and 6 hours. In lung tissue, insulin-like growth factor-1, insulin-like growth factor binding proteins (IGFBPs) and insulin-like growth factor-1 receptor, and IGFBP1 and IGFBP2 mRNA expression were increased in the high-dose nandrolone group at 6 hours. Nandrolone abuse may hasten the death of patients with septic shock and may aggravate septic shock in mice. Copyright © 2011. Published by Elsevier B.V.
Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H
2015-07-01
High doses in Tg.rasH2 carcinogenicity studies are usually set at the maximum tolerated dose (MTD), although this dose selection strategy has not been critically evaluated. We analyzed the body weight gains (BWGs), mortality, and tumor response in control and treated groups of 29 Tg.rasH2 studies conducted at BioReliance. Based on our analysis, it is evident that the MTD was exceeded at the high and/or mid-doses in several studies. The incidence of tumors in high doses was lower when compared to the low and mid-doses of both sexes. Thus, we recommend that the high dose in male mice should not exceed one-half of the estimated MTD (EMTD), as it is currently chosen, and the next dose should be one-fourth of the EMTD. Because females were less sensitive to decrements in BWG, the high dose in female mice should not exceed two-third of EMTD and the next dose group should be one-third of EMTD. If needed, a third dose group should be set at one-eighth EMTD in males and one-sixth EMTD in females. In addition, for compounds that do not show toxicity in the range finding studies, a limit dose should be applied for the 26-week carcinogenicity studies. © 2014 by The Author(s).
ERIC Educational Resources Information Center
Kawamura, Anne; Campbell, Kent; Lam-Damji, Sophie; Fehlings, Darcy
2007-01-01
This study compared the effects of low and high doses of botulinum toxin A (BTX-A) to improve upper extremity function. Thirty-nine children (22 males, 17 females) with a mean age of 6 years 2 months (SD 2y 9mo) diagnosed with spastic hemiplegia or triplegia were enrolled into this double-blind, randomized controlled trial. The high-dose group…
NASA Astrophysics Data System (ADS)
Lee, Chang Yeol; Kim, Woo Chul; Kim, Hun Jeong; Huh, Hyun Do; Park, Seungwoo; Choi, Sang Hyoun; Kim, Kum Bae; Min, Chul Kee; Kim, Seong Hoon; Shin, Dong Oh
2017-02-01
The purpose of this study is to perform a comparison and on analysis of measured dose factor values by using various commercially available high-energy electron beam detectors to measure dose profiles and energy property data. By analyzing the high-energy electron beam data from each detector, we determined the optimal detector for measuring electron beams in clinical applications. The dose linearity, dose-rate dependence, percentage depth dose, and dose profile of each detector were measured to evaluate the dosimetry characteristics of high-energy electron beams. The dose profile and the energy characteristics of high-energy electron beams were found to be different when measured by different detectors. Through comparison with other detectors based on the analyzed data, the microdiamond detector was found to have outstanding dose linearity, a low dose-rate dependency, and a small effective volume. Thus, this detector has outstanding spatial resolution and is the optimal detector for measuring electron beams. Radiation therapy results can be improved and related medical accidents can be prevented by using the procedure developed in this research in clinical practice for all beam detectors when measuring the electron beam dose.
Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.
Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang
2014-02-01
Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Hakim, Hana; Allison, Kim J; Van de Velde, Lee-Ann; Tang, Li; Sun, Yilun; Flynn, Patricia M; McCullers, Jonathan A
2016-06-08
Approaches to improve the immune response of immunocompromised patients to influenza vaccination are needed. Children and young adults (3-21 years) with cancer or HIV infection were randomized to receive 2 doses of high-dose (HD) trivalent influenza vaccine (TIV) or of standard-dose (SD) TIV. Hemagglutination inhibition (HAI) antibody titers were measured against H1, H3, and B antigens after each dose and 9 months later. Seroconversion was defined as ≥4-fold rise in HAI titer comparing pre- and post-vaccine sera. Seroprotection was defined as a post-vaccine HAI titer ≥1:40. Reactogenicity events (RE) were solicited using a structured questionnaire 7 and 14 days after each dose of vaccine, and adverse events by medical record review for 21 days after each dose of vaccine. Eighty-five participants were enrolled in the study; 27 with leukemia, 17 with solid tumor (ST), and 41 with HIV. Recipients of HD TIV had significantly greater fold increase in HAI titers to B antigen in leukemia group and to H1 antigen in ST group compared to SD TIV recipients. This increase was not documented in HIV group. There were no differences in seroconversion or seroprotection between HD TIV and SD TIV in all groups. There was no difference in the percentage of solicited RE in recipients of HD TIV (54% after dose 1 and 38% after dose 2) compared to SD TIV (40% after dose 1 and 20% after dose 2, p=0.27 and 0.09 after dose 1 and 2, respectively). HD TIV was more immunogenic than SD TIV in children and young adults with leukemia or ST, but not with HIV. HD TIV was safe and well-tolerated in children and young adults with leukemia, ST, or HIV. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tang, W H Wilson; Vagelos, Randall H; Yee, Yin-Gail; Fowler, Michael B
2004-11-01
The impact of angiotensin-converting enzyme (ACE) gene polymorphism on neurohormonal dose response to ACE inhibitor therapy is unclear. ACE Insertion (I) or Deletion (D) genotype was determined in 74 patients with chronic heart failure who were randomly assigned to receive either high-dose or low-dose enalapril over a period of 6 months. Monthly pre-enalapril and post-enalapril neurohormone levels (serum ACE activity (sACE), plasma angiotensin II (A-II), plasma renin activity (PRA), and serum aldosterone (ALDO) were compared between genotype subgroups and between patients who received high- or low-dose enalapril within each genotype subgroup. At baseline, predose/postdose sACE and postdose PRA were significantly higher in the DD genotype. At 6-month follow-up, postdose sACE was reduced in a dose-dependent fashion in all three genotypes (P < .05). However, predose and postdose ALDO and A-II levels did not differ between each genotype subgroup at baseline or by enalapril dose within each genotype subgroup. ALDO escape and A-II reactivation were not affected by ACE genotype or enalapril dosage. Predose sACE were consistently higher in the DD genotype when compared with ID or II subgroups. Despite a dose-dependent suppression of sACE, there were no observed statistically significant differences in ALDO and A-II suppression or escape with escalating doses of enalapril within each subgroup.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pedicini, Piernicola, E-mail: ppiern@libero.it; Caivano, Rocchina; Fiorentino, Alba
2012-01-01
To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose onmore » PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d{sub 2cc}, d{sub 1cc}, and d{sub max} (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.« less
Yam, Karen K.; Gupta, Jyotsana; Winter, Kaitlin; Allen, Elizabeth; Brewer, Angela; Beaulieu, Édith; Mallett, Corey P.; Burt, David S.; Ward, Brian J.
2015-01-01
During the 2009–2010 influenza pandemic, an adjuvanted, dose-sparing vaccine was recommended for most Canadians. We hypothesize that differences exist in the responses to AS03-adjuvanted, low antigen (Ag) dose versus unadjuvanted, full-dose vaccines. We investigated the relationship between Ag dose and the oil-in-water emulsion Adjuvant System AS03. BALB/c mice received two IM doses of AS03A or AS03B with exaggerated dilutions of A/Uruguay/716/2007 H3N2 split virion vaccine Ag. Immune responses were assessed 3 weeks after the booster. Unadjuvanted “high” (3 μg) and low-dose (0.03–0.003 μg) vaccines generated similar serum antibody titers and cytokine secretion patterns in restimulated splenocytes. Compared to unadjuvanted “high-dose” vaccination, both AS03A and AS03B-adjuvanted low-dose vaccines tended to elicit higher serum antibody titers, broader induction of cytokine secretion and generated more influenza-specific antibody secreting cells and cytokine-secreting CD4 and CD8 T cells in splenocytes. We show that varying Ag and/or AS03 dose in this influenza vaccination mouse model can strongly influence both the magnitude and pattern of the immune response elicited. These findings are highly relevant given the likelihood of expanded use of adjuvanted, dose-sparing vaccines and raise questions about the use of “standard” doses of vaccines in pre-clinical vaccine studies. PMID:25972874
Kshirsagar, Abhijit V; Freburger, Janet K; Ellis, Alan R; Wang, Lily; Winkelmayer, Wolfgang C; Brookhart, M Alan
2013-06-01
Intravenous iron is used widely in hemodialysis, yet there are limited data on the effectiveness of contemporary dosing strategies or formulation type. We conducted a retrospective cohort study using data from the clinical database of a large dialysis provider (years 2004-2008) merged with administrative data from the US Renal Data System to compare the effects of intravenous iron use on anemia management. Dosing comparisons were bolus (consecutive doses ≥100 mg exceeding 600 mg during 1 month) versus maintenance (all other iron doses during the month); and high (>200 mg over 1 month) versus low dose (≤200 mg over 1 month). Formulation comparison was administration of ferric gluconate versus iron sucrose over 1 month. Outcomes were hemoglobin, epoetin dose, transferrin saturation, and serum ferritin during 6 weeks of follow-up. We identified 117,050 patients for the dosing comparison, and 66,207 patients for the formulation comparison. Bolus dosing was associated with higher average adjusted hemoglobin (+0.23 g/dL; 95% confidence interval [CI], 0.21-0.26), transferrin saturation (+3.31%; 95% CI, 2.99-3.63), serum ferritin (+151 μg/L; 95% CI, 134.9-168.7), and lower average epoetin dose (-464 units; 95% CI, -583 to -343) compared with maintenance. Similar trends were observed with high-dose iron versus low-dose. Iron sucrose was associated with higher adjusted average hemoglobin (+0.16 g/dL; 95% CI, 0.12-0.19) versus ferric gluconate. Strategies favoring large doses of intravenous iron or iron sucrose lead to improved measures of anemia management. These potential benefits should be weighed against risks, which currently remain incompletely characterized. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.
2014-03-01
We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Reid F.; Zhai, Huifang; Both, Stefan
Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, andmore » IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, Ko; Takahashi, Shoki; Higano, Shuichi
1995-07-15
The main purpose of this study was to determine influential factors related to minor leukoencephalopathy (LEP) caused by moderate-dose methotrexate (MTX) and prophylactic cranial radiotherapy (CRT) in childhood hematopoietic malignancies. We also compared the incidence of LEP following this treatment to that reported in the literature following treatment with high-dose MTX alone. Thirty-eight pediatric patients of hematopoietic malignancies (37 acute lymphoblastic leukemias, 1 non-Hodgkin lymphoma) who were given CRT (18-24 Gy) as well as prophylactic intrathecal and per os MTX were studied for leukoencephalopathy by magnetic resonance (MR) imaging. All the patients were free from grave neuropsychiatric disturbances. The datamore » were examined to elucidate the influential ones of five factors (patients` age, doses of intrathecal and per os MTX, dose of CRT, interval between treatment, and MR study) to develop LEP using multiple regression analysis. To compare the effect of moderate-dose MTX and prophylactic CRT on LEP to that of high-dose MTX alone, we conducted a literature review. Seven out of 38 patients (18%) developed LEP. From multiple regression analysis and partial correlation coefficients, the age and CRT dose seemed influential in the subsequent development of LEP. The incidence of LEP following treatment with moderate-dose MTX and prophylactic CRT appears to be less than that reported in the literature following treatment with intravenous high-dose MTX. However, even moderate-dose MTX in combination with CRT can result in a significant incidence of MR-detectable LEP, particularly in children 6 years of age or younger receiving 24 Gy. Leukoencephalopathy was caused by moderate-dose MTX and prophylactic CRT in pediatric patients, probably less frequently than by high-dose MTX treatment alone. The influential factors were patient`s age and CRT dose. 26 refs., 6 figs., 2 tabs.« less
Salmonella Fecal Shedding and Immune Responses are Dose- and Serotype- Dependent in Pigs
Ivanek, Renata; Österberg, Julia; Gautam, Raju; Sternberg Lewerin, Susanna
2012-01-01
Despite the public health importance of Salmonella infection in pigs, little is known about the associated dynamics of fecal shedding and immunity. In this study, we investigated the transitions of pigs through the states of Salmonella fecal shedding and immune response post-Salmonella inoculation as affected by the challenge dose and serotype. Continuous-time multistate Markov models were developed using published experimental data. The model for shedding had four transient states, of which two were shedding (continuous and intermittent shedding) and two non-shedding (latency and intermittent non-shedding), and one absorbing state representing permanent cessation of shedding. The immune response model had two transient states representing responses below and above the seroconversion level. The effects of two doses [low (0.65×106 CFU/pig) and high (0.65×109 CFU/pig)] and four serotypes (Salmonella Yoruba, Salmonella Cubana, Salmonella Typhimurium, and Salmonella Derby) on the models' transition intensities were evaluated using a proportional intensities model. Results indicated statistically significant effects of the challenge dose and serotype on the dynamics of shedding and immune response. The time spent in the specific states was also estimated. Continuous shedding was on average 10–26 days longer, while intermittent non-shedding was 2–4 days shorter, in pigs challenged with the high compared to low dose. Interestingly, among pigs challenged with the high dose, the continuous and intermittent shedding states were on average up to 10–17 and 3–4 days longer, respectively, in pigs infected with S. Cubana compared to the other three serotypes. Pigs challenged with the high dose of S. Typhimurium or S. Derby seroconverted on average up to 8–11 days faster compared to the low dose. These findings highlight that Salmonella fecal shedding and immune response following Salmonella challenge are dose- and serotype-dependent and that the detection of specific Salmonella strains and immune responses in pigs are time-sensitive. PMID:22523553
Wu, Jian; Liu, Shen-lin; Zhang, Xing-xing; Chen, Min; Zou, Xi
2015-09-01
To observe the effect of Jianpi Yangzheng Xiaozheng Recipe (JYXR) on the tumor inhibition rate of subcutaneous transplanted tumor gastric cancer cell line MGC-803 in BALB/c nude mice, and to study its molecular mechanism of apoptosis and autophagy. Gastric cancer cell line MGC-803 was subcutaneously inoculated to nude mice for preparing transplanted gastric cancer models. Totally 32 BALB/c nude mice were randomly divided into 4 groups according to random digit table, i.e., the negative control group, the positive control group, the high dose JYXR group, the low dose JYXR group, 8 in each group. Normal saline was administered to mice in the negative control group by gastrogavage. 5-fluorouracil (5-Fu) at 2. 5 mg/kg was administered to mice in the positive control group by gastrogavage. JYXR at 85 and 43 g/kg was administered to mice in the high dose JYXR group and the low dose JYXR group by gastrogavage, once per day for 10 successive days. The effect of JYXR on the tumor inhibition rate of subcutaneous transplanted tumor was observed. Effects of JYXR on gene expression levels of Bax, Bcl-2, Fas, Cyclin D1, Cyclin D2, and Cyclin D3 in transplanted tumor were observed by real-time PCR. Effects of JYXR on protein expression levels of Procaspase-3, Procaspase-8, Procaspase-9, cleaved-PARP, Beclin-1, and LC3B were detected using Western blot. (1) Compared with the negative control group, the tumor weight was obviously reduced in the rest three groups (P <0. 05). The tumor weight was higher in the high dose JYXR group and the low dose JYXR group than in the positive control group (P <0. 05). (2) Results of RT-PCR indicated that, compared with the negative control group, expression levels of Bax were up-regulated, but expression levels of Bcl-2, Cyclin D1, Cyclin D2, and Cyclin D3 were down-regulated in the positive control group and JYXR groups (P <0. 05). The expression level of Fas was up-regulated in the positive control group and the high dose JYXR group (P <0. 05). Compared with the positive control group, expression levels of Fas, and Bax were all down-regulated, but expression levels of Bcl-2, Cyclin D2, and Cyclin D3 were all up-regulated in the high dose JYXR group and the low dose JYXR group (all P <0. 05). The expression level of Cyclin D1 was down-regulated in the high dose JYXR group, but it was up-regulated in the low dose JYXR group ( both P <0. 05). (3) Results of Western blot showed, compared with the negative control group, expression levels of Procaspase-3, Procaspase-8, and Procaspase-9 were down-regulated, but expression levels of cleaved-PARP, Beclin-1, and LC3B II were up-regulated in the high dose JYXR group and the low dose JYXR group (all P <0.05). Compared with the negative control group, expression levels of Procaspase-3, Procaspase-8, Procaspase-9, and LC3B II were down-regulated, but expression levels of cleaved-PARP, Beclin-1, and LC3B I were up-regulated in the positive control group (all P <0. 05). JYXR showed significant inhibition on subcutaneous transplanted tumor gastric cancer cell line MGC-803 in BALB/c nude mice. Its mechanism might be associated with activating apoptosis and autophagy correlated factors.
Palmer, Antony L; Dimitriadis, Alexis; Nisbet, Andrew; Clark, Catharine H
2015-11-21
There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200-2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison.
NASA Astrophysics Data System (ADS)
Palmer, Antony L.; Dimitriadis, Alexis; Nisbet, Andrew; Clark, Catharine H.
2015-11-01
There is renewed interest in film dosimetry for the verification of dose delivery of complex treatments, particularly small fields, compared to treatment planning system calculations. A new radiochromic film, Gafchromic EBT-XD, is available for high-dose treatment verification and we present the first published evaluation of its use. We evaluate the new film for MV photon dosimetry, including calibration curves, performance with single- and triple-channel dosimetry, and comparison to existing EBT3 film. In the verification of a typical 25 Gy stereotactic radiotherapy (SRS) treatment, compared to TPS planned dose distribution, excellent agreement was seen with EBT-XD using triple-channel dosimetry, in isodose overlay, maximum 1.0 mm difference over 200-2400 cGy, and gamma evaluation, mean passing rate 97% at 3% locally-normalised, 1.5 mm criteria. In comparison to EBT3, EBT-XD gave improved evaluation results for the SRS-plan, had improved calibration curve gradients at high doses, and had reduced lateral scanner effect. The dimensions of the two films are identical. The optical density of EBT-XD is lower than EBT3 for the same dose. The effective atomic number for both may be considered water-equivalent in MV radiotherapy. We have validated the use of EBT-XD for high-dose, small-field radiotherapy, for routine QC and a forthcoming multi-centre SRS dosimetry intercomparison.
Vitamin C modulates lead excretion in rats.
Lihm, Hoseob; Kim, Hyun; Chang, Heekyung; Yoon, Myunghee; Lee, Kayoung; Choi, Jongsoon
2013-12-01
Lead, one of the most toxic heavy metals, takes longer time to be excreted from the body than other heavy metals. The purpose of this study is, by measuring lead excretion via urine and feces, to find out the effect of vitamin C in lead chelation. Thirty-six rats were randomly assorted into four groups. All 33 rats except for the control group were administered with lead, before orally administered with different doses of vitamin C per kilogram of body weight. The lead excretion levels in urine and feces as well as the survival rate were then measured for each group. The rats with lead administrations (10/13, 76.9%) with lead administrations only, 10/11 rats (90.9%) with lead administrations and low dose of vitamin C, 9/9 rats (100%) with lead administrations and high dose of vitamin C survived. Among the 29 surviving rats, low vitamin C intake group exhibited higher urinary excretion than the lead only group. The urinary excretion level in high dose vitamin C intakegroup was significantly higher than the lead only group. In addition, fecal lead excretion seemed to be increased in the high dose vitamin C intake group, compared to the group with lead administrations only with statistical significance. Through animal experiment, it was found out that administrating high dose of vitamin C accelerated the excretion of lead in body compared to low dose of vitamin C.
The effect of high-dose dronabinol (oral THC) maintenance on cannabis self-administration.
Schlienz, Nicolas J; Lee, Dustin C; Stitzer, Maxine L; Vandrey, Ryan
2018-06-01
There is a clear need for advancing the treatment of cannabis use disorders. Prior research has demonstrated that dronabinol (oral THC) can dose-dependently suppress cannabis withdrawal and reduce the acute effects of smoked cannabis. The present study was conducted to evaluate whether high-dose dronabinol could reduce cannabis self-administration among daily users. Non-treatment seeking daily cannabis users (N = 13) completed a residential within-subjects crossover study and were administered placebo, low-dose dronabinol (120 mg/day; 40 mg tid), or high-dose dronabinol (180-240 mg/day; 60-80 mg tid) for 12 consecutive days (order counterbalanced). During each 12-day dronabinol maintenance phase, participants were allowed to self-administer smoked cannabis containing <1% THC (placebo) or 5.7% THC (active) under forced-choice (drug vs. money) or progressive ratio conditions. Participants self-administered significantly more active cannabis compared with placebo in all conditions. When active cannabis was available, self-administration was significantly reduced during periods of dronabinol maintenance compared with placebo maintenance. There was no difference in self-administration between the low- and high-dose dronabinol conditions. Chronic dronabinol dosing can reduce cannabis self-administration in daily cannabis users and suppress withdrawal symptoms. Cannabinoid agonist medications should continue to be explored for therapeutic utility in the treatment of cannabis use disorders. Copyright © 2018 Elsevier B.V. All rights reserved.
Berry, Donald A.; Ueno, Naoto T.; Johnson, Marcella M.; Lei, Xiudong; Caputo, Jean; Smith, Dori A.; Yancey, Linda J.; Crump, Michael; Stadtmauer, Edward A.; Biron, Pierre; Crown, John P.; Schmid, Peter; Lotz, Jean-Pierre; Rosti, Giovanni; Bregni, Marco; Demirer, Taner
2011-01-01
Purpose High doses of effective chemotherapy are compelling if they can be delivered safely. Substantial interest in supporting high-dose chemotherapy with bone marrow or autologous hematopoietic stem-cell transplantation in the 1980s and 1990s led to the initiation of randomized trials to evaluate its effect in the treatment of metastatic breast cancer. Methods We identified six randomized trials in metastatic breast cancer that evaluated high doses of chemotherapy with transplant support versus a control regimen without stem-cell support. We assembled a single database containing individual patient information from these trials. The primary analysis of overall survival was a log-rank test comparing high dose versus control. We also used Cox proportional hazards regression, adjusting for known covariates. We addressed potential treatment differences within subsets of patients. Results The effect of high-dose chemotherapy on overall survival was not statistically different (median, 2.16 v 2.02 years; P = .08). A statistically significant advantage in progression-free survival (median, 0.91 v 0.69 years) did not translate into survival benefit. Subset analyses found little evidence that there are groups of patients who might benefit from high-dose chemotherapy with hematopoietic support. Conclusion Overall survival of patients with metastatic breast cancer in the six randomized trials was not significantly improved by high-dose chemotherapy; any benefit from high doses was small. No identifiable subset of patients seems to benefit from high-dose chemotherapy. PMID:21768454
Callera, Glaucia E.; Antunes, Tayze T.; Correa, Jose W.; Moorman, Danielle; Gutsol, Alexey; He, Ying; Cat, Aurelie Nguyen Dinh; Briones, Ana M.; Montezano, Augusto C.; Burns, Kevin D.; Touyz, Rhian M.
2016-01-01
High doses of Ang II receptor (AT1R) blockers (ARBs) are renoprotective in diabetes. Underlying mechanisms remain unclear. We evaluated whether high/ultra-high doses of candesartan (ARB) up-regulate angiotensin-converting enzyme 2 (ACE2)/Ang II type 2 receptor (AT2R)/Mas receptor [protective axis of the of the renin–angiotensin system (RAS)] in diabetic mice. Systolic blood pressure (SBP), albuminuria and expression/activity of RAS components were assessed in diabetic db/db and control db/+ mice treated with increasing candesartan doses (intermediate, 1 mg/kg/d; high, 5 mg/kg/d; ultra-high, 25 and 75 mg/kg/d; 4 weeks). Lower doses candesartan did not influence SBP, but ultra-high doses reduced SBP in both groups. Plasma glucose and albuminuria were increased in db/db compared with db/+ mice. In diabetic mice treated with intermediate dose candesartan, renal tubular damage and albuminuria were ameliorated and expression of ACE2, AT2R and Mas and activity of ACE2 were increased, effects associated with reduced ERK1/2 phosphorylation, decreased fibrosis and renal protection. Ultra-high doses did not influence the ACE2/AT2R/Mas axis and promoted renal injury with increased renal ERK1/2 activation and exaggerated fibronectin expression in db/db mice. Our study demonstrates dose-related effects of candesartan in diabetic nephropathy: intermediate–high dose candesartan is renoprotective, whereas ultra-high dose candesartan induces renal damage. Molecular processes associated with these effects involve differential modulation of the ACE2/AT2R/Mas axis: intermediate–high dose candesartan up-regulating RAS protective components and attenuating pro-fibrotic processes, and ultra-high doses having opposite effects. These findings suggest novel mechanisms through the protective RAS axis, whereby candesartan may ameliorate diabetic nephropathy. Our findings also highlight potential injurious renal effects of ultra-high dose candesartan in diabetes. PMID:27612496
Priyadarshika, R C U; Crosbie, J C; Kumar, B; Rogers, P A W
2011-01-01
Objectives Microbeam radiotherapy (MRT) with wafers of microscopically narrow, synchrotron generated X-rays is being used for pre-clinical cancer trials in animal models. It has been shown that high dose MRT can be effective at destroying tumours in animal models, while causing unexpectedly little damage to normal tissue. The aim of this study was to use a dermatopathological scoring system to quantify and compare the acute biological response of normal mouse skin with microplanar and broad-beam (BB) radiation as a basis for biological dosimetry. Method The skin flaps of three groups of mice were irradiated with high entrance doses (200 Gy, 400 Gy and 800 Gy) of MRT and BB and low dose BB (11 Gy, 22 Gy and 44 Gy). The mice were culled at different time-points post-irradiation. Skin sections were evaluated histologically using the following parameters: epidermal cell death, nuclear enlargement, spongiosis, hair follicle damage and dermal inflammation. The fields of irradiation were identified by γH2AX-positive immunostaining. Results The acute radiation damage in skin from high dose MRT was significantly lower than from high dose BB and, importantly, similar to low dose BB. Conclusion The integrated MRT dose was more relevant than the peak or valley dose when comparing with BB fields. In MRT-treated skin, the apoptotic cells of epidermis and hair follicles were not confined to the microbeam paths. PMID:21849367
High-Dose Oral Ibuprofen in Treatment of Patent Ductus Arteriosus in Full-Term Neonates.
Pourarian, Shahnaz; Rezaie, Mehrdad; Amoozgar, Hamid; Shakiba, Ali-Mohammad; Edraki, Mohammad-Reza; Mehdizadegan, Nima
2015-08-01
Patent ductus arteriosus (PDA) is an important risk for heart failure due to left to right shunt in term neonates. In this study, we evaluated the effect of high dose ibuprofen in closure of PDA in term neonates. We used double dose ibuprofen (20 mg/kg, 10 mg/kg, and 10 mg/kg) for 3 - 30 day old term neonates with PDA who were admitted in the neonatal wards of Shiraz University of Medical Sciences. The results of this study were compared to the data of the previous study in our center which used the low dose of ibuprofen (10 mg/kg, 5 mg/kg, and 5 mg/kg). 29 full term neonates received high-dose ibuprofen, in 18 neonates, PDA was closed after 4 days (62.1% versus 43.3% for the standard dose and 4.7% for the control group in the previous study) (P = 0.001). The results showed no significant correlation between the closure rate and gestational age, postnatal age, sex, and weight. In the 4(th) day of treatment, size of the pulmonic end of ductus arteriosus decreased from 2.09 mm to 0.77 mm compared to 1.68 mm to 0.81 mm in the standard dose of oral ibuprofen and 2.1 mm to 1.4 mm in the control group (P = 0.046). This study indicated that high-dose oral ibuprofen was more effective in closing or decreasing the size of PDA.
He, Ying; Chan, Esther W; Man, Kenneth K C; Lau, Wallis C Y; Leung, Wai K; Ho, Lai M; Wong, Ian C K
2014-09-01
A histamine-2 receptor antagonist (H2RA) is one of the common gastroprotective co-therapies used with non-steroidal anti-inflammatory drugs (NSAIDs) for the prevention or treatment of peptic ulcers (PUs). To date, no study has directly compared the prophylactic effectiveness between high-dose and low-dose H2RA. Our objective was to compare the effectiveness of high-dose versus low-dose H2RAs in the primary prophylaxis of PUs among short-term NSAID users. A retrospective cohort study was conducted using the Clinical Data Analysis and Reporting System (CDARS) in Hong Kong. Patients aged 18 years or above who received a single prescription of oral NSAID with oral H2RA were identified within the study period (1 January 2009-31 December 2012). Patients with a history of or risk factors for PU in the corresponding 2 years prior to the index date (of the first NSAID prescription) were excluded. Log binomial regression analysis was used to calculate the relative risk of PU among NSAID users with high-dose H2RA versus low-dose H2RA exposure. Among the NSAID cohort (n = 102,042), 77,509 (76 %) were on low-dose H2RA and 24,533 (24 %) were on high-dose H2RA. Of the total 69 PU cases identified during the drug exposure period, 64 (0.08 %) received low-dose-H2RA and five (0.02 %) received high-dose H2RA. The overall absolute risk of PUs for NSAID users whilst on H2RA was approximately 1 per 1,479 patients. The adjusted relative risk for NSAID users receiving high-dose H2RA versus low-dose H2RA was 0.32 (95 % confidence interval [CI] 0.13-0.79). Patients aged ≥65 years, receiving a longer duration of treatment, or with concomitant use of antiplatelet agents were found to be at higher risk of PU. High-dose H2RA showed greater effectiveness than low-dose H2RA in the primary prophylaxis of NSAID-associated PUs in short-term new users.
Older adults and high-risk medication administration in the emergency department.
Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J
2017-01-01
Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated ("High doses" were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; "very high doses" were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65-69, 70-74, 75-79, 80-84, and ≥85 years), gender, and hospital. There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65-69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56-11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69-18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26-1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07-2.16). Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65-69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted.
Xie, Y H; Li, X P; Xu, Z X; Qian, P; Li, X L; Wang, Y Q
2016-09-02
In this research, compound Maqin decoction (CMD) has been shown to positively affect in airway inflammation of asthma models. We evaluated the effects of CMD on the expression of transforming growth factor (TGF)-β1/Smad proteins, interleukin (IL)-17, and IL-10 in lung tissue of asthmatic rats. Asthma was induced in a rat model using ovalbumin. After a 4-week treatment with CMD, rats were killed to evaluate the expression of TGF-β1 and Smad proteins in lung tissue. IL-10 and IL-17 levels in lung tissue homogenates were determined by ELISA. The expression of TGF-β1 and Smad3 protein increased, whereas expression of Smad7 protein decreased upon high-dose or low-dose treatment with CMD or by intervention with dexamethasone, compared to the control. There was a significant difference between treatment with a high dose CMD and the control treatment, but no significant difference was found between high-dose CMD treatment and dexamethasone intervention. The expression of TGF-β1 and Smad7 protein increased, whereas the expression of Smad3 protein decreased in the model group compared to other groups. In the CMD high-dose group, low-dose group, and dexamethasone intervention group, the IL-17 concentrations in lung tissue homogenates were decreased, while IL-10 levels were increased. Again, there was a significant difference between CMD high-dose and control treatment, but not between CMD high-dose treatment and dexamethasone intervention. Thus, positive effects of CMD against asthmatic airway remodeling may be due to its regulatory effect on TGF-β1, Smad3, and Smad7 protein levels and on cytokines such as IL-10 and IL-17.
Zelefsky, Michael J; Greco, Carlo; Motzer, Robert; Magsanoc, Juan Martin; Pei, Xin; Lovelock, Michael; Mechalakos, Jim; Zatcky, Joan; Fuks, Zvi; Yamada, Yoshiya
2014-01-01
Purpose To report tumor local progression-free outcomes following treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Methods and Materials Between 2004 and 2010, a total of 105 lesions from renal cell carcinomas were treated with either SD-IGRT to prescription doses of 18–24 Gy (median, 24 Gy) or hypofractionation (3 or 5 fractions) with prescription doses ranging between 20 and 30 Gy. The median follow-up was 12 months (range, 1–48 months). Results The overall 3-year actuarial local progression-free survival (LPFS) for all lesions was 44%. The 3-year LPFS for those who received high single-dose (24 Gy; n = 45), low single-dose (< 24 Gy; n = 14), and hypofractionation regimens (n = 46) were 88%, 21%, and 17%, respectively (high single dose versus low single dose, p = 0.001; high single dose versus hypofractionation, p < 0.001). Multivariate analysis revealed the following variables as significant predictors of improved LPFS: dose of 24 Gy compared with lower dose (p = 0.009), and single dose versus hypofractionation (p = 0.008). Conclusion High-dose SD-IGRT is a non-invasive procedure resulting in high probability of local tumor control for metastatic renal cell cancers, generally considered radioresistant according to classical radiobiological ranking. PMID:21596489
Gandhi, Ranju; Sunder, Rani
2012-01-01
Background: Analgesic efficacy of rectal acetaminophen is variable in different surgical procedures. Little data is available on its efficacy in ophthalmic surgeries. We conducted this prospective, randomized, double blind study to evaluate and compare the efficacy of single high dose and low dose rectal acetaminophen in pediatric ophthalmic surgery over a 24 hour period. Materials and Methods: 135 children scheduled for elective ophthalmic surgery were randomly allocated to one of the three groups, high, low, or control (H, L, or N) and received rectal acetaminophen 40 mg/kg, 20 mg/kg or no rectal drug respectively after induction of general anesthesia. Postoperative observations included recovery score, hourly observational pain score (OPS) up to 8 hours, time to first analgesic demand, and requirement of rescue analgesics and antiemetics over a 24 hour period. Results: Nineteen of 30 (63%) of children in group N required postoperative rescue analgesic versus 5/48 (10%) of group H (P <0.0001) and 10/47 (23%) of group L (P =0.0005) during 24 hour period. Mean time to requirement of first analgesic was 206±185 min in group H, 189±203min in group L, and 196 ±170 min in group N (P=0.985). OPS was significantly lower in group H and L compared to group N during first 8 hours. Requirement of rescue antiemetic was 18.7% in group H as compared to 23% each in group L and group N (P >0.5). Conclusions: Single dose rectal acetaminophen can provide effective postoperative analgesia for pediatric ophthalmic surgery at both high dose (40 mg/kg) and low dose (20 mg/kg) both in early postoperative and over a 24 hour period. PMID:23225924
NASA Astrophysics Data System (ADS)
Mota, C. L.; Pickler, A.; Braz, D.; Barroso, R. C.; Mantuano, A.; Salata, C.; Ferreira-Machado, S. C.; Lau, C. C.; de Almeida, C. E.
2018-04-01
In the last decades, studies showed that the exposure to low doses of ionizing radiation of the body could sense and activate the cell signaling pathways needed to respond to any induced cellular damage. This procedure reduces cell killing compared with a single dose of high radiation dose. Damage to the vasculature can affect the function of most body organs by restricting blood flow and oxygen to tissues; however, the heart and brain are of main concern. The precise relationship between long-term health effects and low-dose exposures remain poorly understood. Biological markers are powerful tools that can be used to determine dose- response relationships and to estimate risk, especially when dealing with, the effects of low dose exposures in humans. These markers should be specific, sensitive, as well as easy and fast to quantify. Various types of biologic specimens are potential candidates for identifying biomarkers but blood has the advantage of being minimally invasive to obtain. In this study, we propose to apply total reflection X-ray fluorescence to quantify possible chemical elemental concentration (sulfer, iron, zinc, potassium and calcium) changes in blood and heart tissues of Wistar rats after total body irradiation with low (0.1 Gy) and high (2.5 Gy) doses. The fluorescence measurements were carried out at the X-ray Fluorescence beamline in the Brazilian Synchrotron Light Laboratory. The results showed that the irradiated animals with low doses have significant alterations in blood and cardiac tissue when compared with animals that received high doses of radiation. Taken together the analysis of all the elements, we can observe that the radiation induced oxidative stress may be the leading cause for alteration of the elemental level in the studied samples.
Direct plan comparison of RapidArc and CyberKnife for spine stereotactic body radiation therapy
NASA Astrophysics Data System (ADS)
Choi, Young Eun; Kwak, Jungwon; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul
2015-07-01
We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan by using an analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both the CK and the RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended by the RTOG 0631 spine and 0915 lung SBRT protocols. The mean CI' SD values of the PTV were 1.11' 0.03 and 1.17' 0.10 for RA and CK ( p = 0.02), respectively. On average, the maximum dose delivered to the spinal cord in CK plans was approximately 11.6% higher than that in RA plans, and this difference was statistically significant ( p < 0.001). High-dose spillages were 0.86% and 2.26% for RA and CK ( p = 0.203), respectively. Intermediate-dose spillage characterized by D2cm was lower for RA than for CK; however, R50% was not statistically different. Even though both systems can create highly conformal volumetric dose distributions, the current study shows that RA demonstrates lower high- and intermediate-dose spillages than CK. Therefore, RA plans for spinal SBRT may be superior to CK plans.
[The role of CYP2E1 in the protection of garlic oil's from n-hexane-induced neurotoxicity].
Bi, Ye; Chen, Jing-jing; Li, Yang; Fu, Qiang-qiang; Zeng, Tao; Xie, Ke-qin
2011-11-01
To study the role of CYP2E1 in the protective effects and mechanism of garlic oil (GO) on the peripheral nerve injuries induced by n-hexane. Fifty male Wistar rats were randomly divided into five groups (n = 10): the control, the GO (80 mg/kg) control, the n-hexane (2000 mg/kg) model, the low dose GO (40 mg/kg) plus n-hexane, and the high dose GO (80 mg/kg) plus n-hexane groups. All rats were treated by intragastric administration 6 times a week for 10 weeks. The gait scores were determined every two weeks for monitoring the peripheral neurotrosis. All rats were sacrificed in 10 weeks, the activities and expression levels of hepatic CYP2E1 and 2, 5-HD in serum were examined. As compared with control group, the content and activity of hepatic CYP2E1 in GO control group reduced by 83.1% and 48.3% respectively (P < 0.01), the content and activity of hepatic CYP2E1 in model group increased by 112.5% and 72.2% respectively (P < 0.01). As compared with model group, the contents of hepatic CYP2E1 in low dose and high dose GO groups reduced by 32.9% and 39.1% respectively, the activities of hepatic CYP2E1 in low dose and high dose GO groups reduced by 27.4% and 44.5% respectively (P < 0.01); the contents of serum 2,5-HD in low dose and high dose GO groups reduced by 47.7% and 78.7% respectively (P < 0.01). The gait scores in model, low dose and high dose GO groups were significantly lower than that in control group, but the gait scores in low dose and high dose GO groups were significantly lower than that in model group (P < 0.05). Garlic oil can effectively reduce the peripheral neurotrosis induced by n-hexane due to the decreased content and activity of hepatic CYP2E1, resulting in the reduced formation of 2, 5-HD from n-hexane.
Arican, Pinar; Dundar, Nihal Olgac; Gencpinar, Pinar; Cavusoglu, Dilek
2017-01-01
Bell's palsy is the most common cause of acute peripheral facial nerve paralysis, but the optimal dose of corticosteroids in pediatric patients is still unclear. This retrospective study aimed to evaluate the efficacy of low-dose corticosteroid therapy compared with high-dose corticosteroid therapy in children with Bell's palsy. Patients were divided into 2 groups based on the dose of oral prednisolone regimen initiated. The severity of idiopathic facial nerve paralysis was graded according to the House-Brackmann Grading Scale. The patients were re-assessed in terms of recovery rate at the first, third, and sixth months of treatment. There was no significant difference in complete recovery between the 2 groups after 1, 3, and 6 months of treatment. In our study, we concluded that even at a dose of 1 mg/kg/d, oral prednisolone was highly effective in the treatment of Bell's palsy in children.
Krishna, Sanjeev; Planche, Tim; Agbenyega, Tsiri; Woodrow, Charles; Agranoff, Dan; Bedu-Addo, George; Owusu-Ofori, Alex K.; Appiah, John Adabie; Ramanathan, Surash; Mansor, Sharif M.; Navaratnam, Visweswaran
2001-01-01
We report the first detailed pharmacokinetic assessment of intrarectal (i.r.) artesunate (ARS) in African children. Artesunate was given intravenously (i.v.; 2.4 mg/kg of body weight) and i.r. (10 or 20 mg/kg formulated as 50- or 200-mg suppositories [Rectocaps]) in a crossover study design to 34 Ghanaian children with moderate falciparum malaria. The median relative bioavailability of dihydroartemisinin (DHA), the active antimalarial metabolite of ARS, was higher in the low-dose i.r. group (10 mg/kg) than in the high-dose i.r. group (20 mg/kg) (58 versus 23%; P = 0.018). There was wide interpatient variation in the area under the concentration-time curve after i.r. ARS administration (up to 9-fold in the high-dose group and 20-fold in the low-dose group). i.r. administered ARS was more rapidly absorbed in the low-dose group than the high-dose group (median [range] absorption half-lives, 0.7 h [0.3 to 1.24 h] versus 1.1 h [0.6 to 2.7 h] [P = 0.023]. i.r. administered ARS was eliminated with a median (range) half-life of 0.8 h (0.4 to 2.7 h) (low-dose group and 0.9 h (0.1 to 2.5 h) (high-dose group) (P = 1). The fractional clearances of DHA were 3.9, 2.6, and 1.5 liters/kg/h for the 20-mg/kg, 10-mg/kg and i.v. groups, respectively (P = 0.001 and P = 0.06 for the high-and low-dose i.r. groups compared with the i.v. groups, respectively). The median volumes of distribution for DHA were 1.5 liters kg (20 mg/kg, i.r. group), 1.8 liters/kg (10 mg/kg, i.r. group), and 0.6 liters/kg (i.v. group) (P < 0.05 for both i.r. groups compared with the i.v. group). Parasite clearance kinetics were comparable in all treatment groups. i.r. administered ARS may be a useful alternative to parenterally administered ARS in the management of moderate childhood malaria and should be studied further. PMID:11158748
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, S; Department of Biomedical Engineering, University of North Carolina- Chapel Hill/ North Carolina State University, Chapel Hill, North Carolina; Lineberger Clinical Cancer Center, University of North Carolina, Chapel Hill, NC
Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression andmore » cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.« less
Sinakos, Emmanouil; Marschall, Hanns-Ulrich; Kowdley, Kris V.; Befeler, Alex; Keach, Jill; Lindor, Keith
2010-01-01
High-dose (28-30mg/kg/day) ursodeoxycholic acid (UDCA) treatment improves serum liver tests in patients with primary sclerosing cholangitis (PSC) but does not improve survival and is associated with increased rates of serious adverse events. The mechanism for the latter undesired effect remains unclear. High-dose UDCA could result in the production of hepatotoxic bile acids, such as lithocholic acid (LCA), due to limited small bowel absorption of UDCA and conversion of UDCA by bacteria in the colon. We determined the serum bile acid composition in 56 patients with PSC previously enrolled in a randomized, double-blind controlled trial of high dose UDCA versus placebo. Samples for analysis were obtained at baseline and at the end of treatment. The mean changes in UDCA (16.86 vs 0.05 μmol/L) and total bile acid (17.21 vs −0.55 μmol/L) levels were significantly higher in the UDCA group (n=29) compared to placebo (n=27) when pretreatment levels were compared (p<0.0001). LCA was also markedly increased (0.22 vs 0.01 μmol/L) in the UDCA group compared to placebo (p=0.001). No significant changes were detected for cholic acid (CA), deoxycholic acid (DCA) and chenodeoxycholic acid (CDCA). Patients (n=9) in the UDCA group who reached clinical endpoints of disease progression (development of cirrhosis, varices, liver transplantation or death) tend to have greater increase in their post-treatment total bile acid levels (34.99 vs 9.21 μmol/L) (p<0.08) compared to those who did not. Conclusion High-dose UDCA treatment in PSC patients results in marked UDCA enrichment and significant expansion of the total serum bile acid pool including lithocholic acid. PMID:20564380
Lip, Gregory Y H; Lanitis, Tereza; Kongnakorn, Thitima; Phatak, Hemant; Chalkiadaki, Corina; Liu, Xianchen; Kuznik, Andreas; Lawrence, Jack; Dorian, Paul
2015-11-01
The purpose of this analysis was to assess the cost-effectiveness of apixaban 5 mg BID versus high- and low-dose edoxaban (60 mg and 30 mg once daily) as intended starting dose strategies for stroke prevention in patients from a UK National Health Service perspective. A previously developed and validated Markov model was adapted to evaluate the lifetime clinical and economic impact of apixaban 5 mg BID versus edoxaban (high and low dose) in patients with nonvalvular atrial fibrillation. A pairwise indirect treatment comparison was conducted for clinical end points, and price parity was assumed between apixaban and edoxaban. Costs in 2012 British pounds, life-years, and quality-adjusted life-years (QALYs) gained, discounted at 3.5% per annum, were estimated. Apixaban was predicted to increase life expectancy and QALYs versus low- and high-dose edoxaban. These gains were achieved at cost-savings versus low-dose edoxaban, thus being dominant and nominal increases in costs versus high-dose edoxaban. The incremental cost-effectiveness ratio of apixaban versus high-dose edoxaban was £6763 per QALY gained. Apixaban was deemed to be dominant (less costly and more effective) versus low-dose edoxaban and a cost-effective alternative to high-dose edoxaban. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Kim, Won Young; Jun, Jong Hun; Huh, Jin Won; Hong, Sang Bum; Lim, Chae-Man; Koh, Younsuck
2013-12-01
The accuracy of arterial blood pressure (ABP) monitoring is crucial in treating septic shock patients. Clinically significant differences in central to peripheral ABP could develop into sepsis during vasopressor therapy. The aim of this study was to investigate the difference between radial (peripheral) and femoral (central) ABP in septic shock patients receiving high-dose norepinephrine (NE) therapy. This prospective observational study comparing simultaneous intra-arterial measurements of radial and femoral ABP was performed at a university-affiliated, tertiary referral center between October 2008 and March 2009. Patients with septic shock who needed continuous blood pressure monitoring and high-dose NE therapy 0.1 µg/kg per minute or greater to maintain mean arterial pressure (MAP) of 65 mmHg or greater were included. Statistical analysis was conducted using the Bland-Altman method for comparison of repeated measures. In total, 250 sets of systolic, mean, and diastolic femoral and radial ABP were recorded at baseline and after NE titration. Arterial blood pressure readings from the radial artery were underestimated compared with those from the femoral artery. Overall bias (mean difference between simultaneous measurements) between radial and femoral MAP was +4.9 mmHg; however, during high-dose NE therapy, the bias increased to +6.2 mmHg (95% limits of agreement: -6.0 to +18.3 mmHg). Clinically significant radial-femoral MAP differences (MAP ≥5 mmHg) occurred in up to 62.2% of patients with high-dose NE therapy. Radial artery pressure frequently underestimates central pressure in septic shock patients receiving high-dose NE therapy. Femoral arterial pressure monitoring may be more appropriate when high-dose NE therapy is administered.
A Pilot Study: Cardiac Parameters in Children Receiving New-Generation Antidepressants.
Uchida, Mai; Spencer, Andrea E; Kenworthy, Tara; Chan, James; Fitzgerald, Maura; Rosales, Ana Maria; Kagan, Elana; Saunders, Alexandra; Biederman, Joseph
2017-06-01
Because of concerns about potential associations between high doses of citalopram and QTc prolongation in adults, this study examined whether such associations are operant in children. We hypothesized that therapeutic doses of nontricyclic antidepressant medications (non-TCAs) prescribed to children would be cardiovascularly safe. The sample consisted of 49 psychiatrically referred children and adolescents 6 to 17 years old of both sexes treated with a non-TCA (citalopram, escitalopram, fluoxetine, paroxetine, sertraline, bupropion, duloxetine, venlafaxine, mirtazapine). To standardize the doses of different antidepressants, we converted doses of individual medicines into "citalopram equivalent doses" (CEDs) based on dosing recommendation for individual antidepressants. Correlation analysis was carried out to compare the continuous and weight-based CED to variables of interest. A QTc grouping was defined as normal, borderline, or abnormal, and CED was compared across QTc groupings using linear regression. An antidepressant dosage group was defined as low or high dose, and a t test compared variables of interest across dosage groups. No significant associations were found between total or weight-corrected CEDs of any antidepressant examined and QTc or any other electrocardiogram or blood pressure parameters. In patients taking citalopram or escitalopram, a significant correlation was found between PR interval and total daily dose, which disappeared when weight-based doses were used or when corrected by age. Although limited by a relatively small sample size, these results suggest that therapeutic doses of non-TCA antidepressants when used in children do not seem to be associated with prolonged QTc interval or other adverse cardiovascular effects.
NASA Astrophysics Data System (ADS)
Safitri, Yunita Diyah; Widyarti, Sri; Rifa'i, Muhaimin
2017-05-01
People who have unbalanced lifestyles and habits such as consuming high fat and sugar foods, as well as the lack of physical activity, have an increased risk of obesity and related metabolic diseases. The condition of obesity occurs due to an excess of nutrients which leads to low-grade inflammation. Inflammation induced by obesity causes unstable bone marrow homeostasis which is associated with proliferation and differentiation of Hematopoietic Stem Cells (HSCs). This study aimed to observe the erythroid progenitor (TER-119) and complement regulator (CD59) on bone marrow cells in mouse models fed a high fat-fructose diet (HFFD). This research was conducted by modeling obese mice using high fat and fructose food for 20 weeks, and then treating them with elicited soybean extract (ESE) for four weeks with several doses: low dose (78 mg/kgBB), moderate dose (104 mg/kgBB) and high dose (130 mg/kgBB). Cell TER119+CD59+ expression decreased in the HFFD group compared to the normal group. In the low, moderate and high dose group, TER119+CD59+ expression significantly increased compared to the HFFD group. These results demonstrate that soybean elicited extract can improve the hematopoietic system by increasing TER119+CD59+ expression in a high fat and fructose diet mouse model.
Creemers-Schild, Dina; Kroon, Frank P; Kuijper, Ed J; de Boer, Mark G J
2016-06-01
The recommended treatment of Pneumocystis jirovecii pneumonia (PCP) is high-dose trimethoprim-sulfamethoxazole (TMP-SMX) in an equivalent of TMP 15-20 mg/kg/day and SMX 75-100 mg/kg/day for 2 or 3 weeks. High rates of adverse events are reported with this dose, which raises the question if lower doses are possible. All adult patients diagnosed with PCP in various immune dysfunctions and treated with TMP-SMX between January 1, 2003 and July 1, 2013 in a tertiary university hospital were included. Per institutional protocol, patients initiated treatment on intermediate-dose TMP-SMX (TMP 10-15 mg/kg/day) and could be stepped down to low-dose TMP-SMX (TMP 4-6 mg/kg/day) during treatment. Clinical variables at presentation, relapse rate and mortality rates were compared between intermediate- and step-down treatment groups by uni- and multivariate analyses. A total of 104 patients were included. Twenty-four patients (23 %) were switched to low-dose TMP-SMX after a median of 4.5 days (IQR 2.8-7.0 days). One relapse (4 %) occurred in the step-down group versus none in the intermediate-dose group. The overall 30-day mortality was 13 %. There was 1 death in the step-down group (4 %) compared to 13 deaths (16 %) in the intermediate-dose group. We observed high cure rates of PCP by treatment with intermediate-dose TMP-SMX. In addition, a step-down strategy to low-dose TMP-SMX during treatment in selected patients appears to be safe and does not compromise the outcome of treatment.
Reference dosimetry using radiochromic film
Girard, Frédéric; Bouchard, Hugo
2012-01-01
The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparing the performance of three lots of GAFCHROMIC EBT2 films stored at either 4°C or room temperature. The effect of high (>80%) or low (<20%) relative humidity was also determined. Doses measured in optimal conditions with EBT and EBT2 films were then compared with an A12 ionization chamber measurement. Intensity‐modulated radiation therapy quality controls using EBT2 films were also performed in reference dose. The results obtained using reference dose measurements were compared with those obtained using relative dose measurements. Storing the film at 4°C improves the stability of the film over time, but does not eliminate the noncatalytic film development, seen as a rise in optical density over time in the absence of radiation. Relative humidity variations ranging from 80% to 20% have a strong impact on the optical density and could introduce dose errors of up to 15% if the humidity were not controlled during the film storage period. During the scanning procedure, the film temperature influences the optical density that is measured. When controlling for these three parameters, the dose differences between EBT or EBT2 and the A12 chamber are found to be within ±4% (2σ level) over a dose range of 20–350 cGy. Our results also demonstrate the limitation of the Anisotropic Analytical Algorithm for dose calculation of highly modulated treatment plans. PACS numbers: 87.55.Qr; 87.56.Fc PMID:23149793
Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography.
Kerl, Hans Ulrich; Isaza, Cristina T; Boll, Hanne; Schambach, Sebastian J; Nolte, Ingo S; Groden, Christoph; Brockmann, Marc A
2011-01-01
Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.
Comparative study of two negative CAR resists: EN-024M and NEB 31
NASA Astrophysics Data System (ADS)
Baik, Ki-Ho; Dean, Robert; Lem, Homer Y.; Osborne, Stephen P.; Mueller, Mark A.; Cole, Damon M.
2004-08-01
In this paper, two negative-tone chemically amplified resists (CAR) are evaluated. The methodology and results are compared and discussed. The resists include EN-024M from TOK, and NEB 31 from Sumitomo. Both resists show high contrast, good dry etch selectivity, and high environmental stability. EN-024M showed good coating uniformity while NEB31 showed a coating uniformity problem. This was a round "dimple" approximately one centimeter in diameter of different thickness and density at the center of the plate. We addressed the "dimple" coating problem as described in the paper. Optimum PAB and PEB temperatures and nominal to maximum doses for isolated features were determined by running a matrix of PAB and PEB temperatures along with a dose series. We evaluated the process and compared the lithographic performance in terms of dose sensitivity, dose and bake latitude, resolution, resist profile, OPC (Optical Proximity Correction) pattern fidelity, CD uniformity, environmental stability, Line Edge Roughness (LER) and etching bias and resistance.
Jae, Hwan Jun; Chung, Jin Wook; Park, Hee Sun; Lee, Min Jong; Lee, Ki Chang; Kim, Hyo-Cheol; Yoon, Jung Hwan; Chung, Hesson; Park, Jae Hyung
2009-01-01
The purpose of this study was to compare the antitumor effect and hepatotoxicity of an intraarterial delivery of low-dose and high-dose 3-bromopyruvate (3-BrPA) and those of a conventional Lipiodol-doxorubicin emulsion in a rabbit VX2 hepatoma model. This experiment was approved by the animal care committee at our institution. VX2 carcinoma was implanted in the livers of 36 rabbits. Transcatheter intraarterial administration was performed using low dose 3-BrPA (25 mL in a 1 mM concentration, n = 10), high dose 3-BrPA (25 mL in a 5 mM concentration, n = 10) and Lipiodol-doxorubicin emulsion (1.6 mg doxorubicin/ 0.4 mL Lipiodol, n = 10), and six rabbits were treated with normal saline alone as a control group. One week later, the proportion of tumor necrosis was calculated based on histopathologic examination. The hepatotoxicity was evaluated by biochemical analysis. The differences between these groups were statistically assessed with using Mann-Whitney U tests and Kruskal-Wallis tests. The tumor necrosis rate was significantly higher in the high dose group (93% +/- 7.6 [mean +/- SD]) than that in the control group (48% +/- 21.7) (p = 0.0002), but the tumor necrosis rate was not significantly higher in the low dose group (62% +/- 20.0) (p = 0.2780). However, the tumor necrosis rate of the high dose group was significantly lower than that of the Lipiodol-doxorubicin treatment group (99% +/- 2.7) (p = 0.0015). The hepatotoxicity observed in the 3-BrPA groups was comparable to that of the Lipiodol-doxorubicin group. Even though intraarterial delivery of 3-BrPA shows a dose-related antitumor effect, single session treatment seems to have limited efficacy when compared with the conventional method.
Jae, Hwan Jun; Park, Hee Sun; Lee, Min Jong; Lee, Ki Chang; Kim, Hyo-Cheol; Yoon, Jung Hwan; Chung, Hesson; Park, Jae Hyung
2009-01-01
Objective The purpose of this study was to compare the antitumor effect and hepatotoxicity of an intraarterial delivery of low-dose and high-dose 3-bromopyruvate (3-BrPA) and those of a conventional Lipiodol-doxorubicin emulsion in a rabbit VX2 hepatoma model. Materials and Methods This experiment was approved by the animal care committee at our institution. VX2 carcinoma was implanted in the livers of 36 rabbits. Transcatheter intraarterial administration was performed using low dose 3-BrPA (25 mL in a 1 mM concentration, n = 10), high dose 3-BrPA (25 mL in a 5 mM concentration, n = 10) and Lipiodol-doxorubicin emulsion (1.6 mg doxorubicin/ 0.4 mL Lipiodol, n = 10), and six rabbits were treated with normal saline alone as a control group. One week later, the proportion of tumor necrosis was calculated based on histopathologic examination. The hepatotoxicity was evaluated by biochemical analysis. The differences between these groups were statistically assessed with using Mann-Whitney U tests and Kruskal-Wallis tests. Results The tumor necrosis rate was significantly higher in the high dose group (93% ± 7.6 [mean ± SD]) than that in the control group (48% ± 21.7) (p = 0.0002), but the tumor necrosis rate was not significantly higher in the low dose group (62% ± 20.0) (p = 0.2780). However, the tumor necrosis rate of the high dose group was significantly lower than that of the Lipiodol-doxorubicin treatment group (99% ± 2.7) (p = 0.0015). The hepatotoxicity observed in the 3-BrPA groups was comparable to that of the Lipiodol-doxorubicin group. Conclusion Even though intraarterial delivery of 3-BrPA shows a dose-related antitumor effect, single session treatment seems to have limited efficacy when compared with the conventional method. PMID:19885316
Dugernier, Jonathan; Hesse, Michel; Jumetz, Thibaud; Bialais, Emilie; Roeseler, Jean; Depoortere, Virginie; Michotte, Jean-Bernard; Wittebole, Xavier; Ehrmann, Stephan; Laterre, Pierre-François; Jamar, François; Reychler, Gregory
2017-10-01
High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo ® ; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer ® ; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow ® ; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.
On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy.
Peppa, Vasiliki; Pappas, Eleftherios; Major, Tibor; Takácsi-Nagy, Zoltán; Pantelis, Evaggelos; Papagiannis, Panagiotis
2016-07-01
To study the effect of finite patient dimensions and tissue heterogeneities in head and neck high dose rate brachytherapy. The current practice of TG-43 dosimetry was compared to patient specific dosimetry obtained using Monte Carlo simulation for a sample of 22 patient plans. The dose distributions were compared in terms of percentage dose differences as well as differences in dose volume histogram and radiobiological indices for the target and organs at risk (mandible, parotids, skin, and spinal cord). Noticeable percentage differences exist between TG-43 and patient specific dosimetry, mainly at low dose points. Expressed as fractions of the planning aim dose, percentage differences are within 2% with a general TG-43 overestimation except for the spine. These differences are consistent resulting in statistically significant differences of dose volume histogram and radiobiology indices. Absolute differences of these indices are however small to warrant clinical importance in terms of tumor control or complication probabilities. The introduction of dosimetry methods characterized by improved accuracy is a valuable advancement. It does not appear however to influence dose prescription or call for amendment of clinical recommendations for the mobile tongue, base of tongue, and floor of mouth patient cohort of this study. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lloyd, S. A. M.; Ansbacher, W.; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 3P6
2013-01-15
Purpose: Acuros external beam (Acuros XB) is a novel dose calculation algorithm implemented through the ECLIPSE treatment planning system. The algorithm finds a deterministic solution to the linear Boltzmann transport equation, the same equation commonly solved stochastically by Monte Carlo methods. This work is an evaluation of Acuros XB, by comparison with Monte Carlo, for dose calculation applications involving high-density materials. Existing non-Monte Carlo clinical dose calculation algorithms, such as the analytic anisotropic algorithm (AAA), do not accurately model dose perturbations due to increased electron scatter within high-density volumes. Methods: Acuros XB, AAA, and EGSnrc based Monte Carlo are usedmore » to calculate dose distributions from 18 MV and 6 MV photon beams delivered to a cubic water phantom containing a rectangular high density (4.0-8.0 g/cm{sup 3}) volume at its center. The algorithms are also used to recalculate a clinical prostate treatment plan involving a unilateral hip prosthesis, originally evaluated using AAA. These results are compared graphically and numerically using gamma-index analysis. Radio-chromic film measurements are presented to augment Monte Carlo and Acuros XB dose perturbation data. Results: Using a 2% and 1 mm gamma-analysis, between 91.3% and 96.8% of Acuros XB dose voxels containing greater than 50% the normalized dose were in agreement with Monte Carlo data for virtual phantoms involving 18 MV and 6 MV photons, stainless steel and titanium alloy implants and for on-axis and oblique field delivery. A similar gamma-analysis of AAA against Monte Carlo data showed between 80.8% and 87.3% agreement. Comparing Acuros XB and AAA evaluations of a clinical prostate patient plan involving a unilateral hip prosthesis, Acuros XB showed good overall agreement with Monte Carlo while AAA underestimated dose on the upstream medial surface of the prosthesis due to electron scatter from the high-density material. Film measurements support the dose perturbations demonstrated by Monte Carlo and Acuros XB data. Conclusions: Acuros XB is shown to perform as well as Monte Carlo methods and better than existing clinical algorithms for dose calculations involving high-density volumes.« less
Comparison of fluence-to-dose conversion coefficients for deuterons, tritons and helions.
Copeland, Kyle; Friedberg, Wallace; Sato, Tatsuhiko; Niita, Koji
2012-02-01
Secondary radiation in aircraft and spacecraft includes deuterons, tritons and helions. Two sets of fluence-to-effective dose conversion coefficients for isotropic exposure to these particles were compared: one used the particle and heavy ion transport code system (PHITS) radiation transport code coupled with the International Commission on Radiological Protection (ICRP) reference phantoms (PHITS-ICRP) and the other the Monte Carlo N-Particle eXtended (MCNPX) radiation transport code coupled with modified BodyBuilder™ phantoms (MCNPX-BB). Also, two sets of fluence-to-effective dose equivalent conversion coefficients calculated using the PHITS-ICRP combination were compared: one used quality factors based on linear energy transfer; the other used quality factors based on lineal energy (y). Finally, PHITS-ICRP effective dose coefficients were compared with PHITS-ICRP effective dose equivalent coefficients. The PHITS-ICRP and MCNPX-BB effective dose coefficients were similar, except at high energies, where MCNPX-BB coefficients were higher. For helions, at most energies effective dose coefficients were much greater than effective dose equivalent coefficients. For deuterons and tritons, coefficients were similar when their radiation weighting factor was set to 2.
Role of particle radiotherapy in the management of head and neck cancer.
Laramore, George E
2009-05-01
Modern imaging techniques and powerful computers allow a radiation oncologist to design treatments delivering higher doses of radiation than previously possible. Dose distributions imposed by the physics of 'standard' photon and electron beams limit further dose escalation. Hadron radiotherapy offers advantages in either dose distribution and/or improved radiobiology that may significantly improve the treatment of certain head and neck malignancies. Clinical studies support the effectiveness of fast-neutron radiotherapy in the treatment of major and minor salivary gland tumors. Data show highly favorable outcomes with proton radiotherapy for skull-base malignancies and tumors near highly critical normal tissues compared with that expected with standard radiotherapy. Heavy-ion radiotherapy clinical studies are mainly being conducted with fully stripped carbon ions, and limited data seem to indicate a possible improvement over proton radiotherapy for the same subset of radioresistant tumors where neutrons show a benefit over photons. Fast-neutron radiotherapy has different radiobiological properties compared with standard radiotherapy but similar depth dose distributions. Its role in the treatment of head and neck cancer is currently limited to salivary gland malignancies and certain radioresistant tumors such as sarcomas. Protons have the same radiobiological properties as standard radiotherapy beams but more optimal depth dose distributions, making it particularly advantageous when treating tumors adjacent to highly critical structures. Heavy ions combine the radiobiological properties of fast neutrons with the physical dose distributions of protons, and preliminary data indicate their utility for radioresistant tumors adjacent to highly critical structures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mwidu, U; Devic, S; Shehadeh, M
Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended bymore » the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.« less
Pomalidomide for Multiple Myeloma
A summary of results from a phase III trial that compared the combination of pomalidomide (Pomalyst®) and low-dose dexamethasone versus high-dose dexamethasone alone in patients with multiple myeloma that has progressed despite other treatments.
Round-robin study of arsenic implant dose measurement in silicon by SIMS
NASA Astrophysics Data System (ADS)
Simons, D.; Kim, K.; Benbalagh, R.; Bennett, J.; Chew, A.; Gehre, D.; Hasegawa, T.; Hitzman, C.; Ko, J.; Lindstrom, R.; MacDonald, B.; Magee, C.; Montgomery, N.; Peres, P.; Ronsheim, P.; Yoshikawa, S.; Schuhmacher, M.; Stockwell, W.; Sykes, D.; Tomita, M.; Toujou, F.; Won, J.
2006-07-01
An international round-robin study was undertaken under the auspices of ISO TC201/SC6 to determine the best analytical conditions and the level of interlaboratory agreement for the determination of the implantation dose of arsenic in silicon by secondary ion mass spectrometry (SIMS). Fifteen SIMS laboratories, as well as two laboratories that performed low energy electron-induced X-ray emission spectrometry (LEXES) and one that made measurements by instrumental neutron activation analysis (INAA) were asked to determine the implanted arsenic doses in three unknown samples using as a comparator NIST Standard Reference Material ® 2134. The use of a common reference material by all laboratories resulted in better interlaboratory agreement than was seen in a previous round-robin that lacked a common comparator. The relative standard deviation among laboratories was less than 4% for the medium-dose sample, but several percent larger for the low- and high-dose samples. The high-dose sample showed a significant difference between point-by-point and average matrix normalization because the matrix signal decreased in the vicinity of the implant peak, as observed in a previous study. The dose from point-by-point normalization was in close agreement with that determined by INAA. No clear difference in measurement repeatability was seen when comparing Si 2- and Si 3- as matrix references with AsSi -.
Williams, Michael T; Gutierrez, Arnold; Vorhees, Charles V
2018-06-08
Permethrin is a Type I (non-cyano) pyrethroid that induces tremors at high concentrations and increases acoustic startle responses (ASR) in adult rodents, however its effects in young rats have been investigated to a limited extent. ASR and tremor were assessed in adult and postnatal day (P)15 Sprague-Dawley rats at oral doses of 60, 90, or 120 mg/kg over an 8 h period. Permethrin increased ASR in adults, regardless of dose, and 20% of the high-dose rats showed tremor at later time points. For the P15 rats all doses induced tremor at all time points, and ASR was increased at 2 h in the 90 and 120 mg/kg groups with a trend in the 60 mg/kg group compared with controls. The 60 mg/kg group showed increased ASR at 4 and 6 h, whereas the 90 mg/kg group showed no differences from the controls at these times. The 120 mg/kg group showed decreased ASR from 4-8 h post-treatment. P15 and adult rats both showed plasma and brain cis- and trans-permethrin increases after dosing. After the same dose of permethrin, P15 rats had greater cis- and trans-permethrin in brain and plasma compared with adults. P15 rats had an increased tremor response compared with adults even at comparable brain permethrin concentrations. For ASR, P15 rats responded sooner and showed a biphasic pattern ranging from increased to decreased response as a function of dose and time, unlike adults that only showed increases. Overall, young rats showed greater effects from permethrin compared with adults.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorissen, BL; Giantsoudi, D; Unkelbach, J
Purpose: Cell survival experiments suggest that the relative biological effectiveness (RBE) of proton beams depends on linear energy transfer (LET), leading to higher RBE near the end of range. With intensity-modulated proton therapy (IMPT), multiple treatment plans that differ in the dose contribution per field may yield a similar physical dose distribution, but the RBE-weighted dose distribution may be disparate. RBE models currently do not have the required predictive power to be included in an optimization model due to the variations in experimental data. We propose an LET-based planning method that guides IMPT optimization models towards plans with reduced RBE-weightedmore » dose in surrounding organs at risk (OARs) compared to inverse planning based on physical dose alone. Methods: Optimization models for physical dose are extended with a term for dose times LET (doseLET). Monte Carlo code is used to generate the physical dose and doseLET distribution of each individual pencil beam. The method is demonstrated for an atypical meningioma patient where the target volume abuts the brainstem and partially overlaps with the optic nerve. Results: A reference plan optimized based on physical dose alone yields high doseLET values in parts of the brainstem and optic nerve. Minimizing doseLET in these critical structures as an additional planning goal reduces the risk of high RBE-weighted dose. The resulting treatment plan avoids the distal fall-off of the Bragg peaks for shaping the dose distribution in front of critical stuctures. The maximum dose in the OARs evaluated with RBE models from literature is reduced by 8–14\\% with our method compared to conventional planning. Conclusion: LET-based inverse planning for IMPT offers the ability to reduce the RBE-weighted dose in OARs without sacrificing target dose. This project was in part supported by NCI - U19 CA 21239.« less
Eaton, John E.; Silveira, Marina G.; Pardi, Darrell S.; Sinakos, Emmanouil; Kowdley, Kris V.; Luketic, Velimir A.C.; Harrison, M. Edwyn; McCashland, Timothy; Befeler, Alex S.; Harnois, Denise; Jorgensen, Roberta; Petz, Jan; Lindor, Keith D.
2011-01-01
OBJECTIVES Some studies have suggested that ursodeoxycholic acid (UDCA) may have a chemopreventive effect on the development of colorectal neoplasia in patients with ulcerative colitis (UC) and primary sclerosing cholangitis (PSC). We examined the effects of high-dose (28–30 mg/kg/day) UDCA on the development of colorectal neoplasia in patients with UC and PSC. METHODS Patients with UC and PSC enrolled in a prior, multicenter randomized placebo-controlled trial of high-dose UDCA were evaluated for the development of colorectal neoplasia. Patients with UC and PSC who received UDCA were compared with those who received placebo. We reviewed the pathology and colonoscopy reports for the development of low-grade or high-grade dysplasia or colorectal cancer. RESULTS Fifty-six subjects were followed for a total of 235 patient years. Baseline characteristics (including duration of PSC and UC, medications, patient age, family history of colorectal cancer, and smoking status) were similar for both the groups. Patients who received high-dose UDCA had a significantly higher risk of developing colorectal neoplasia (dysplasia and cancer) during the study compared with those who received placebo (hazard ratio: 4.44, 95% confidence interval: 1.30–20.10, P=0.02). CONCLUSIONS Long-term use of high-dose UDCA is associated with an increased risk of colorectal neoplasia in patients with UC and PSC. PMID:21556038
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niewald, Marcus, E-mail: marcus.niewald@uks.eu; Seegenschmiedt, M. Heinrich; Micke, Oliver
2012-11-15
Purpose: To conduct a randomized trial of radiation therapy for painful heel spur, comparing a standard dose with a very low dose. Methods and Materials: Sixty-six patients were randomized to receive radiation therapy either with a total dose of 6.0 Gy applied in 6 fractions of 1.0 Gy twice weekly (standard dose) or with a total dose of 0.6 Gy applied in 6 fractions of 0.1 Gy twice weekly (low dose). In all patients lateral opposing 4- to 6-MV photon beams were used. The results were measured using a visual analogue scale, the Calcaneodynia score, and the SF12 health survey.more » The fundamental phase of the study ended after 3 months, and the follow-up was continued up to 1 year. Patients with insufficient pain relief after 3 months were offered reirradiation with the standard dosage at any time afterward. Results: Of 66 patients, 4 were excluded because of withdrawal of consent or screening failures. After 3 months the results in the standard arm were highly significantly superior compared with those in the low-dose arm (visual analogue scale, P=.001; Calcaneodynia score, P=.027; SF12, P=.045). The accrual of patients was stopped at this point. Further evaluation after 12 months' follow-up showed the following results: (1) highly significant fewer patients were reirradiated in the standard arm compared with the low-dose arm (P<.001); (2) the results of patients in the low-dose arm who were reirradiated were identical to those in the standard arm not reirradiated (reirradiation as a salvage therapy if the lower dose was ineffective); (3) patients experiencing a favorable result after 3 months showed this even after 12 months, and some results even improved further between 3 and 12 months. Conclusions: This study confirms the superior analgesic effect of radiation therapy with 6-Gy doses on painful heel spur even for a longer time period of at least 1 year.« less
Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang
2016-01-01
To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D90 of 34Gy in 8.5Gy per fraction, and 145Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2Gy per fraction, EQD2) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The Dmean (EQD2) of rectum decreased 22.36Gy in HDR and 17.01Gy in LDR from 30.24Gy in VMAT, respectively. The Dmean (EQD2) of bladder decreased 6.91Gy in HDR and 2.53Gy in LDR from 13.46Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD2) was 80.26, 70.23, and 104.91Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan
To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR andmore » LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.« less
Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.
Low, D A; Dempsey, J F; Venkatesan, R; Mutic, S; Markman, J; Mark Haacke, E; Purdy, J A
1999-08-01
BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A multidimensional dose comparison tool that simultaneously examines the dose-difference and distance-to-agreement was used to evaluate the gel in both low-and high-dose gradient regions. When 3% and 3 mm criteria were used for the comparisons, more than 90% of the TLD measurements agreed with the gel, with the worst of 309 TLD chip measurements disagreeing by 40% of the criteria. All four MRI measurement session gel-measured dose distributions were compared to evaluate the time behavior of the gel. The low-dose regions were evaluated by comparison with TLD measurements at selected points, while high-dose regions were evaluated by directly comparing measured dose distributions. Tests using the multidimensional comparison tool showed detectable degradation beyond one week postirradiation, but all low-dose measurements passed relative to the test criteria and the dose distributions showed few regions that failed.
Raczniak, Gregory A.; Thomas, Timothy K.; Bulkow, Lisa R.; Negus, Susan E.; Zanis, Carolyn L.; Bruce, Michael G.; Spradling, Philip R.; Teshale, Eyasu H.; McMahon, Brian J.
2015-01-01
Background Hepatitis A is mostly a self-limiting disease but causes substantial economic burden. Consequently, United States Advisory Committee for Immunization Practices recommends inactivated hepatitis A vaccination for all children beginning at age 1 year and for high risk adults. The hepatitis A vaccine is highly effective but the duration of protection is unknown. Methods We examined the proportion of children with protective hepatitis A antibody levels (anti-HAV ≥20 mIU/mL) as well as the geometric mean concentration (GMC) of anti-HAV in a cross sectional convenience sample of individuals aged 12–24 years, who had been vaccinated with a two-dose schedule in childhood, with the initial dose at least 5 years ago. We compared a subset of data from persons vaccinated with two-doses (720 EL.U.) at age 3–6 years with a demographically similar prospective cohort that received a three-dose (360 EL.U.) schedule and have been followed for 17 years. Results No significant differences were observed when comparing GMC between the two cohorts at 10 (P = 0.467), 12 (P = 0.496), and 14 (P = 0.175) years post-immunization. For the three-dose cohort, protective antibody levels remain for 17 years and have leveled-off over the past 7 years. Conclusion The two- and three-dose schedules provide similar protection >14 years after vaccination, indicating a booster dose is not needed at this time. Plateauing anti-HAV GMC levels suggest protective antibody levels may persist long-term. PMID:23470239
Kazakauskaite, Egle; Husmann, Lars; Stehli, Julia; Fuchs, Tobias; Fiechter, Michael; Klaeser, Bernd; Ghadri, Jelena R; Gebhard, Catherine; Gaemperli, Oliver; Kaufmann, Philipp A
2013-02-01
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Meyer, Mathias; Haubenreisser, Holger; Raupach, Rainer; Schmidt, Bernhard; Lietzmann, Florian; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Schad, Lothar R; Schoenberg, Stefan O; Henzler, Thomas
2015-01-01
To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm(2) removes the necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63%/39% lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50% • A smaller focal spot of 0.2 mm (2) significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear.
The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.
Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K
2017-09-01
We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M
2017-05-01
To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI vol : 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose 4 level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose 4 in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose 4 in the CT imaging of a THA phantom.
Sturgeon, Kathleen; Digiovanni, Laura; Good, Jerene; Salvatore, Domenick; Fenderson, Desiré; Domchek, Susan; Stopfer, Jill; Galantino, Mary Lou; Bryan, Cathy; Hwang, Wei-Ting; Schmitz, Kathryn
2016-08-01
Dysregulation of adipokines, such as adiponectin and leptin, is associated with a variety of chronic diseases, including cancer. Physical activity protects against breast cancer and one of the mechanisms which may underlie this association is exercise-induced changes in adipokine levels. The WISER Sister Trial was a three-armed randomized controlled trial in premenopausal women (n = 137) with an elevated risk for breast cancer. A 5-menstrual-cycle-long dosed aerobic exercise intervention compared low-dose exercise (150 min/wk; n = 44) or high-dose exercise (300 min/wk; n = 48) with a control group asked to maintain usual activity levels (n = 45). Exercise intensity progressed to and was maintained at 70% to 80% of age predicted heart rate max. Body composition and adipokine levels were measured at baseline and follow-up. We observed significant linear trends for increased fitness capacity (Δ%: -2.0% control, 10.1% low dose, 13.1% high dose), decreased fat tissue-to-total tissue mass (Δ%: 0.7% control, -2.9% low dose, -3.7% high dose), increased body fat adjusted adiponectin (Δ%: -0.6% control, 0.6% low dose, 0.9% high dose), and decreased body fat adjusted leptin (Δ%: 0.7% control, -8.2% low dose, -10.2% high dose). In this randomized clinical trial of premenopausal women at risk for breast cancer, we demonstrate a dose-response effect of exercise on adiponectin and leptin and that dose response is dependent on changes in body fat. Improved adipokine levels, achieved by aerobic exercise training-induced decreases in body fat, may decrease breast cancer risk for high-risk premenopausal women. Cancer Epidemiol Biomarkers Prev; 25(8); 1195-200. ©2016 AACR. ©2016 American Association for Cancer Research.
Goddard, Lee C; Brodin, N Patrik; Bodner, William R; Garg, Madhur K; Tomé, Wolfgang A
2018-05-01
To investigate whether photon or proton-based stereotactic body radiation therapy (SBRT is the preferred modality for high dose hypofractionation prostate cancer treatment. Achievable dose distributions were compared when uncertainties in target positioning and range uncertainties were appropriately accounted for. 10 patients with prostate cancer previously treated at our institution (Montefiore Medical Center) with photon SBRT using volumetric modulated arc therapy (VMAT) were identified. MRI images fused to the treatment planning CT allowed for accurate target and organ at risk (OAR) delineation. The clinical target volume was defined as the prostate gland plus the proximal seminal vesicles. Critical OARs include the bladder wall, bowel, femoral heads, neurovascular bundle, penile bulb, rectal wall, urethra and urogenital diaphragm. Photon plan robustness was evaluated by simulating 2 mm isotropic setup variations. Comparative proton SBRT plans employing intensity modulated proton therapy (IMPT) were generated using robust optimization. Plan robustness was evaluated by simulating 2 mm setup variations and 3% or 1% Hounsfield unit (HU) calibration uncertainties. Comparable maximum OAR doses are achievable between photon and proton SBRT, however, robust optimization results in higher maximum doses for proton SBRT. Rectal maximum doses are significantly higher for Robust proton SBRT with 1% HU uncertainty compared to photon SBRT (p = 0.03), whereas maximum doses were comparable for bladder wall (p = 0.43), urethra (p = 0.82) and urogenital diaphragm (p = 0.50). Mean doses to bladder and rectal wall are lower for proton SBRT, but higher for neurovascular bundle, urethra and urogenital diaphragm due to increased lateral scatter. Similar target conformality is achieved, albeit with slightly larger treated volume ratios for proton SBRT, >1.4 compared to 1.2 for photon SBRT. Similar treatment plans can be generated with IMPT compared to VMAT in terms of target coverage, target conformality, and OAR sparing when range and HU uncertainties are neglected. However, when accounting for these uncertainties during robust optimization, VMAT outperforms IMPT in terms of achievable target conformity and OAR sparing. Advances in knowledge: Comparison between achievable dose distributions using modern, robust optimization of IMPT for high dose per fraction SBRT regimens for the prostate has not been previously investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, J; Xu, Z; Baker, J
Purpose: To compare three-dimensional conformal radiotherapy (3D CRT) and volumetric-modulated arc therapy (VMAT) in lung stereotactic body radiation therapy (SBRT) Methods: A retrospective study of clinically treated lung SBRT cases treated between 2010 and 2015 at our hospital was performed. All treatment modalities were included in this evaluation (VMAT, 3D CRT, static IMRT, and dynamic conformal arc therapy). However, the majority of treatment modalities were either VMAT or 3D CRT. Treatment times of patients and dosimetric plan quality metrics were compared. Treatment times were calculated based on the time the therapist opened and closed the patient’s treatment plan. This treatmentmore » time closely approximates the utilization time of the treatment room. The dosimetric plan quality metrics evaluated include ICRU conformity index, the volume of 105% prescribed dose outside PTV, the ratio of volume of 50% prescribed dose to the volume of PTV, the percentage of maximum dose at 2 cm away from PTV to the prescribed dose, and the V20 (percentage of lung volume receiving 20 Gy or more). Results: Treatment time comparisons show that on average VMAT has shorter treatment times than 3D CRT. Dose conformity, defined by the ICRU conformity index, and high dose spillage, defined by the volume of 105% dose outside the PTV, is reduced when using VMAT compared to 3D CRT. V20 and intermediate dose spillage/fall-off metrics of VMAT and 3D are not significantly different. Conclusion: Clinically treated lung SBRT cases indicate VMAT is superior to 3D with regard to shorter treatment times, plan dose conformity, and plan high dose spillage.« less
Zhang, Yi; Yang, Chao; Zou, Jian-Zhong; Chen, Fei; Ou, Xia; Zou, Hai-Rong; Wang, Yan
2016-10-20
To compare the effect of low-dose focused ultrasound pre-irradiation and microbubbles for enhancing the ablation effect of high intensity focused ultrasound (HIFU) on VX 2 hepatic tumor in rabbits. Fifty-five rabbits bearing VX 2 hepatic tumor were randomly divided into low-dose pre-irradiation + HIFU ablation group, microbubbles+HIFU ablation group, and HIFU ablation group for corresponding treatments. The pathological changes in the tumors after low-dose irradiation, time for HIFU ablation, tumor volume with coagulative necrosis, energy efficiency factor (EEF), pathological changes in the ablated tumor, and sound channel of HIFU ablation were observed. Tumor cell edema, vacuolar changes in the cytoplasm and tumor interstitial vascular congestion were observed 24 h after low-dose pre-irradiation. The ablation time were significantly shorter, coagulative necrosis volume was larger, and EEF was lower in low-dose irradiation + HIFU ablation group and microbubbles+HIFU ablation group than in simple HIFU ablation group (P<0.05), but the differences between the former two groups were not significant. The effectiveness and stability of the synergistic effect of low-dose pre-irradiation were inferior to microbubbles, but the former ensured a better safety of the sound channel. Low-dose irradiation has comparable synergistic effect in HIFU with microbubbles with such advantages as non-invasiveness, high concentration and good safety, and can be a potentially new method to enhance the efficiency of HIFU.
Thompson, Reid F; Mayekar, Sonal U; Zhai, Huifang; Both, Stefan; Apisarnthanarax, Smith; Metz, James M; Plastaras, John P; Ben-Josef, Edgar
2014-08-01
Uncontrolled local growth is the cause of death in ∼ 30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. The authors compared DS, PBS, and IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6-53.8 and 34.9-52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.
Loganathan, Gopalakrishnan; Subhashree, Venugopal; Breite, Andrew G; Tucker, William W; Narayanan, Siddharth; Dhanasekaran, Maheswaran; Mokshagundam, SriPrakash; Green, Michael L; Hughes, Michael G; Williams, Stuart K; Dwulet, Francis E; McCarthy, Robert C; Balamurugan, Appakalai N
2018-02-01
A high number of human islets can be isolated by using modern purified tissue dissociation enzymes; however, this requires the use of >20 Wunsch units (WU)/g of pancreas for digestion. Attempts to reduce this dose have resulted in pancreas underdigestion and poor islet recovery but improved islet function. In this study, we achieved a high number of functional islets using a low dose of recombinant collagenase enzyme mixture (RCEM-1200 WU rC2 and 10 million collagen-degrading activity [CDA] U of rC1 containing about 209 mg of collagenase to digest a 100-g pancreas). The collagenase dose used in these isolations is about 42% of the natural collagenase enzyme mixture (NCEM) dose commonly used to digest a 100-g pancreas. Low-dose RCEM was efficient in digesting entire pancreases to obtain higher yield (5535 ± 830 and 2582 ± 925 islet equivalent/g, P < .05) and less undigested tissue (16.7 ± 5% and 37.8 ± 3%, P < .05) compared with low-dose NCEM (12WU/g). Additionally, low-dose RCEM islets retained better morphology (confirmed with scanning electron microscopy) and higher in vitro basal insulin release (2391 ± 1342 and 1778 ± 978 μU/mL; P < .05) compared with standard-dose NCEM. Nude mouse bioassay demonstrated better islet function for low-dose RCEM (area under the curve [AUC] 24 968) compared with low-dose (AUC-38 225) or standard-dose NCEM (AUC-38 685), P < .05. This is the first report indicating that islet function can be improved by using low-dose rC1rC2 (RCEM). © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.
Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction
NASA Astrophysics Data System (ADS)
Eck, Brendan L.; Fahmi, Rachid; Fuqua, Christopher; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.
2015-03-01
Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.
Trnková, Petra; Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2010-12-01
The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning.
Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2011-01-01
Purpose The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. Material and methods For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. Results HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. Conclusions HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning. PMID:27853479
Treatment of Narcolepsy with Methamphetamine
Miller, Merrill M.; Hajdukovic, Roza; Erman, Milton K.
2008-01-01
Summary Eight pairs of subjects (each consisting of a narcoleptic and a control matched on the basis of age, sex, educational background and job) were evaluated under the following double-blind, randomized treatment conditions: baseline, placebo, low dose and high dose methamphetamine. Subjects were drug-free for 2 weeks prior to beginning the protocol. Methamphetamine was the only drug taken during the protocol and was given in a single morning dose of 0, 20 or 40–60 mg to narcoleptics and 0, 5 or 10 mg to controls. The protocol was 28 days long, with each of the four treatment conditions lasting 4 days followed by 3 days of washout. Nighttime polysomnography and daytime testing were done during the last 24 hours of each treatment condition. Daytime sleep tendency was assessed with the multiple sleep latency test (MSLT). Daytime performance was assessed with performance tests including a simple, computer-based driving task. Narcoleptics’ mean MSLT sleep latency increased from 4.3 minutes on placebo to 9.3 minutes on high dose, compared with an increase from 10.4 to 17.1 minutes for controls. Narcoleptics’ error rate on the driving task decreased from 2.53% on placebo to 0.33% on high dose, compared with a decrease from 0.22% to 0.16% for controls. The effects of methamphetamine on nocturnal sleep were generally dose-dependent and affected sleep continuity and rapid eye movement (REM) sleep. Elimination half life was estimated to be between 15.9 and 22.0 hours. Mild side effects emerged in a dose-dependent fashion and most often involved the central nervous system and gastrointestinal tract. We concluded that methamphetamine caused a dose-dependent decrease in daytime sleep tendency and improvement in performance in both narcoleptics and controls. Methamphetamine at doses of 40–60 mg allowed narcoleptics to function at levels comparable to those of unmedicated controls. PMID:8341891
Dionet, Claude; Müller-Barthélémy, Melanie; Marceau, Geoffroy; Denis, Jean-Marc; Averbeck, Dietrich; Gueulette, John; Sapin, Vincent; Pereira, Bruno; Tchirkov, Andrei; Chautard, Emmanuel; Verrelle, Pierre
2016-09-01
To analyze the dose rate influence in hyper-radiosensitivity (HRS) of human melanoma cells to very low doses of fast neutrons and to compare to the behaviour of normal human skin fibroblasts. We explored different neutron dose rates as well as possible implication of DNA double-strand breaks (DSB), apoptosis, and energy-provider adenosine-triphosphate (ATP) levels during HRS. HRS in melanoma cells appears only at a very low dose rate (VLDR), while a high dose rate (HDR) induces an initial cell-radioresistance (ICRR). HRS does not seem to be due either to DSB or to apoptosis. Both phenomena (HRS and ICRR) appear to be related to ATP availability for triggering cell repair. Fibroblast survival after neutron irradiation is also dose rate-dependent but without HRS. Melanoma cells or fibroblasts exert their own survival behaviour at very low doses of neutrons, suggesting that in some cases there is a differential between cancer and normal cells radiation responses. Only the survival of fibroblasts at HDR fits the linear no-threshold model. This new insight into human cell responses to very low doses of neutrons, concerns natural radiations, surroundings of accelerators, proton-therapy devices, flights at high altitude. Furthermore, ATP inhibitors could increase HRS during high-linear energy transfer (high-LET) irradiation.
McPherson, Sterling; Howell, Donelle; Lewis, Jennifer; Barbosa-Leiker, Celestina; Bertotti Metoyer, Patrick; Roll, John
2016-04-01
The objective of this experiment was to evaluate the comparative value of cigarettes versus high dose e-cigarettes among nicotine-dependent cigarette smokers when compared with money or use of their usual cigarette brand. The experiment used a within-subject design with four sessions. After baseline assessment, participants attended two 15-min unrestricted smoking sessions: one cigarette smoking session and one e-cigarette smoking session. Participants then attended two multiple-choice procedure (MCP) sessions: a session comparing cigarettes and money and a session comparing e-cigarettes and money. Participants (n=27) had used cigarettes regularly, had never used e-cigarettes, and were not currently attempting to quit smoking. The sample consisted primarily of males (72%), with a mean age of 34 years. When given the opportunity to choose between smoking a cigarette or an e-cigarette, participants chose the cigarette 73.9% of the time. Findings from the MCP demonstrated that after the first e-cigarette exposure sessions, the crossover value for cigarettes ($3.45) was significantly higher compared with the crossover value for e-cigarettes ($2.73). The higher participant preference, self-reported smoking effects, and higher MCP crossover points indicate that cigarettes have a higher comparative value than high dose e-cigarettes among e-cigarette naive smokers.
Wang, Li-hong; Wang, Xu; Yu, Xi-zhong; Xu, Wen-ting
2016-02-01
To investigate the effect of Shouwu Jiangqi Decoction (SJD) on polycystic ovary syndrome (PCOS) with insulin resistance (IR) in rats and to explore the underlining molecular mechanisms. A total of 51 female Sprague-Dawley rats were randomly divided into 6 groups: control group (n=7), model group (n=8), SJD high-dose group (n=9), SJD medium-dose group (n=9), SJD low-dose group (n=9) and DMBG group (n=9). Radioimmunoassay was used to measure serum follicle-stimulating hormone (FSH), luteinizing hormone (LH) and testosterone concentrations and qRT-PCR and western blot were used to examine the expression levels of mRNA and protein respectively of insulin receptor substrate 1 (IRS-1) and phosphatidylinositide 3-kinases (PI3K) p85α in different groups. FSH level significantly decreased in the model group compared with the normal control (P<0.01), and high-dose SJD and DMBG can significantly increase FSH level (P<0.01). LH level showed a mild increase without statistic significance in the model group compared with the control and different dosages of SJD had no significance effect on LH level, while DMBG can significantly decrease LH level (P<0.01). Testosterone level significantly increased in the model group compared with the control group (P<0.01), and high-dose SJD and DMBG can significantly decrease testosterone level (P<0.01). The expression of IRS-1 as well as PI3Kp85α were significantly decreased in the model group compared with the normal control group at both mRNA (P<0.001) and protein (P<0.01) level, and both high-dose SJD and DMBG can enhance IRS-1 and PI3K expression (P<0.05). SJD has potent therapeutic effects on PCOS with IR in rats. The therapeutic effects of SJD on IR and ovulatory dysfunction are probably achieved through correcting the defective insulin signaling transduction.
Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus
2016-01-01
The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. PMID:26994093
Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus
2016-06-01
The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. © The Author 2016. Published by Oxford University Press.
NASA Astrophysics Data System (ADS)
Hälg, R. A.; Besserer, J.; Boschung, M.; Mayer, S.; Lomax, A. J.; Schneider, U.
2014-05-01
In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.
Hälg, R A; Besserer, J; Boschung, M; Mayer, S; Lomax, A J; Schneider, U
2014-05-21
In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelefsky, Michael J., E-mail: zelefskm@mskcc.org; Greco, Carlo; Motzer, Robert
2012-04-01
Purpose: To report tumor local progression-free outcomes after treatment with single-dose, image-guided, intensity-modulated radiotherapy and hypofractionated regimens for extracranial metastases from renal cell primary tumors. Patients and Methods: Between 2004 and 2010, 105 lesions from renal cell carcinoma were treated with either single-dose, image-guided, intensity-modulated radiotherapy to a prescription dose of 18-24 Gy (median, 24) or hypofractionation (three or five fractions) with a prescription dose of 20-30 Gy. The median follow-up was 12 months (range, 1-48). Results: The overall 3-year actuarial local progression-free survival for all lesions was 44%. The 3-year local progression-free survival for those who received a highmore » single-dose (24 Gy; n = 45), a low single-dose (<24 Gy; n = 14), or hypofractionation regimens (n = 46) was 88%, 21%, and 17%, respectively (high single dose vs. low single dose, p = .001; high single dose vs. hypofractionation, p < .001). Multivariate analysis revealed the following variables were significant predictors of improved local progression-free survival: 24 Gy dose compared with a lower dose (p = .009) and a single dose vs. hypofractionation (p = .008). Conclusion: High single-dose, image-guided, intensity-modulated radiotherapy is a noninvasive procedure resulting in high probability of local tumor control for metastatic renal cell cancer generally considered radioresistant according to the classic radiobiologic ranking.« less
Dosimetric variations due to interfraction organ deformation in cervical cancer brachytherapy.
Kobayashi, Kazuma; Murakami, Naoya; Wakita, Akihisa; Nakamura, Satoshi; Okamoto, Hiroyuki; Umezawa, Rei; Takahashi, Kana; Inaba, Koji; Igaki, Hiroshi; Ito, Yoshinori; Shigematsu, Naoyuki; Itami, Jun
2015-12-01
We quantitatively estimated dosimetric variations due to interfraction organ deformation in multi-fractionated high-dose-rate brachytherapy (HDRBT) for cervical cancer using a novel surface-based non-rigid deformable registration. As the number of consecutive HDRBT fractions increased, simple addition of dose-volume histogram parameters significantly overestimated the dose, compared with distribution-based dose addition. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Seamless Phase IIa/IIb and enhanced dose-finding adaptive design.
Yuan, Jiacheng; Pang, Herbert; Tong, Tiejun; Xi, Dong; Guo, Wenzhao; Mesenbrink, Peter
2016-01-01
In drug development, when the drug class has a relatively well-defined path to regulatory approval and the enrollment is slow with certain patient populations, one may want to consider combining studies of different phases. This article considers combining a proof of concept (POC) study and a dose-finding (DF) study with a control treatment. Conventional DF study designs sometimes are not efficient, or do not have a high probability to find the optimal dose(s) for Phase III trials. This article seeks more efficient DF strategies that allow the economical testing of more doses. Hypothetical examples are simulated to compare the proposed adaptive design vs. the conventional design based on different models of the overall quantitative representation of efficacy, safety, and tolerability. The results show that the proposed adaptive design tests more active doses with higher power and comparable or smaller sample size in a shorter overall study duration for POC and DF, compared with a conventional design.
Quantities for assessing high photon doses to the body: a calculational approach.
Eakins, Jonathan S; Ainsbury, Elizabeth A
2018-06-01
Tissue reactions are the most clinically significant consequences of high-dose exposures to ionising radiation. However, currently there is no universally recognized dose quantity that can be used to assess and report generalised risks to individuals following whole body exposures in the high-dose range. In this work, a number of potential dose quantities are presented and discussed, with mathematical modelling techniques employed to compare them and explore when their differences are most or least manifest. The results are interpreted to propose the average (D GRB ) of the absorbed doses to the stomach, small intestine, red bone marrow, and brain as the optimum quantity for informing assessments of risk. A second, maximally conservative dose quantity (D Max ) is also suggested, which places limits on any under-estimates resulting from the adoption of D GRB . The primary aim of this work is to spark debate, with further work required to refine the final choice of quantity or quantities most appropriate for the full range of different potential exposure scenarios.
Zhao, Jing; Liu, Ge-Li; Wei, Ying; Jiang, Li-Hong; Bao, Peng-Li; Yang, Qing-Yan
2016-09-01
The aim of the present study was to investigate the effect of testosterone on glucolipid metabolism and vascular injury in male rats, and examine the underlying molecular mechanisms. A total of 40 male Sprague-Dawley rats were divided into a control group (n=10), high-fat-diet + castration group (n=10), high‑fat‑diet + castration + low dose testosterone group (n=10), and high-fat-diet + castration + high dose testosterone group (n=10). Hematoxylin and eosin staining was performed to evaluate the morphology of the thoracic aortic tissues. Immunohistochemical staining was used to detect biomarkers of the phosphoinositide 3‑kinase (PI3K) signaling pathway. The mRNA and protein expression levels of PI3K, AKT, insulin receptor substrate‑1 (IRS‑1), glucose transporter type 4 (GLUT‑4), nuclear factor (NF)‑κB and tumor necrosis factor (TNF)‑α in the aortas were determined using quantitative polymerase chain reaction and Western blot analyses, respectively. Apoptosis in the aortic tissues was detected using a TUNEL assay. Castration induced apoptosis in the animals fed a high‑fat‑diet, whereas low dose testosterone replacement ameliorated the apoptosis in the aorta. However, the levels of apoptosis was more severe following high‑dose testosterone treatment. Low‑dose testosterone induced upregulation in the levels of IRS‑1, AKT, GLUT‑4 protein, NF‑κB, TNF‑α and PI3K, compared with those in the animals fed a high‑fat diet following castration. A high dose of testosterone resulted in a significant decrease in the levels of IRS‑1, AKT, GLUT‑4, NF‑κB, TNF‑α and PI3K. Compared with the rats in the high‑fat diet + castration group, a low dose of testosterone induced upregulation in the mRNA levels of IRS‑1, AKT and GLUT‑4, and downregulation of the mRNA levels of NF‑κB, TNF‑α and PI3K. A high dose of testosterone resulted in a significant decrease in the levels of IRS‑1, AKT and GLUT‑4, and marked increases in the mRNA levels of NF‑κB, TNF‑α and PI3K, compared with the low dose group. Castration induced marked disorders of glucolipid metabolism and vascular injuries in the pubescent male rats. Low‑dose testosterone treatment was found to ameliorate the vascular damage caused by castration via the PI3K/AKT signaling pathway.
Cameron, Stella H; Alwakeel, Amr J; Goddard, Liping; Hobbs, Catherine E; Gowing, Emma K; Barnett, Elizabeth R; Kohe, Sarah E; Sizemore, Rachel J; Oorschot, Dorothy E
2015-09-01
Perinatal hypoxia-ischemia is a major cause of striatal injury and may lead to cerebral palsy. This study investigated whether delayed administration of bone marrow-derived mesenchymal stem cells (MSCs), at one week after neonatal rat hypoxia-ischemia, was neurorestorative of striatal medium-spiny projection neurons and improved motor function. The effect of a subcutaneous injection of a high-dose, or a low-dose, of MSCs was investigated in stereological studies. Postnatal day (PN) 7 pups were subjected to hypoxia-ischemia. At PN14, pups received treatment with either MSCs or diluent. A subset of high-dose pups, and their diluent control pups, were also injected intraperitoneally with bromodeoxyuridine (BrdU), every 24h, on PN15, PN16 and PN17. This permitted tracking of the migration and survival of neuroblasts originating from the subventricular zone into the adjacent injured striatum. Pups were euthanized on PN21 and the absolute number of striatal medium-spiny projection neurons was measured after immunostaining for DARPP-32 (dopamine- and cAMP-regulated phosphoprotein-32), double immunostaining for BrdU and DARPP-32, and after cresyl violet staining alone. The absolute number of striatal immunostained calretinin interneurons was also measured. There was a statistically significant increase in the absolute number of DARPP-32-positive, BrdU/DARPP-32-positive, and cresyl violet-stained striatal medium-spiny projection neurons, and fewer striatal calretinin interneurons, in the high-dose mesenchymal stem cell (MSC) group compared to their diluent counterparts. A high-dose of MSCs restored the absolute number of these neurons to normal uninjured levels, when compared with previous stereological data on the absolute number of cresyl violet-stained striatal medium-spiny projection neurons in the normal uninjured brain. For the low-dose experiment, in which cresyl violet-stained striatal medium-spiny neurons alone were measured, there was a lower statistically significant increase in their absolute number in the MSC group compared to their diluent controls. Investigation of behavior in another cohort of animals showed that delayed administration of a high-dose of bone marrow-derived MSCs, at one week after neonatal rat hypoxia-ischemia, improved motor function on the cylinder test. Thus, delayed therapy with a high- or low-dose of adult MSCs, at one week after injury, is effective in restoring the loss of striatal medium-spiny projection neurons after neonatal rat hypoxia-ischemia and a high-dose of MSCs improved motor function. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Utsunomiya, S; Kushima, N; Katsura, K
Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cmmore » × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.« less
Chakhtoura, M; El Ghandour, S; Shawwa, K; Akl, EA; Arabi, A; Mahfoud, Z; Habib, RH; Hoballah, H; El Hajj Fuleihan, G
2017-01-01
Introduction Hypovitaminosis D affects one-third to two-thirds of children and pregnant women from the Middle East and North Africa (MENA) region. Objective To evaluate in infants, children, adolescents and pregnant women, from the MENA region, the effect of supplementation with different vitamin D doses on the change in 25-hydroxyvitamin D [25(OH)D] level reached, and other skeletal and non-skeletal outcomes. Methods This is a systematic review of randomized controlled trials of vitamin D supplementation conducted in the MENA region. We conducted a comprehensive literature search in 7 databases, without language or time restriction, until November 2016. Two reviewers abstracted data from the included studies, independently and in duplicate. We calculated the mean difference (MD) and 95% CI of 25(OH)D level reached when at least 2 studies were eligible in each comparison (low (< 800 IU), intermediate (800–2,000 IU) or high (> 2,000 IU) daily dose of vitamin D, or placebo). We pooled data using RevMan version 5.3. Results We identified a total of 15 eligible trials: one in infants, 4 in children and adolescents and 10 in pregnant women. In children and adolescents, an intermediate vitamin D dose (1,901 IU/d), resulted in a mean difference in 25(OH)D level of 13.5 (95% Confidence Interval (CI) 8.1;18.8) ng/ml, compared to placebo, favoring the intermediate dose (p < 0.001). The proportion of children and adolescents reaching a 25(OH)D level ≥ 20 ng/ml was 74% in the intermediate dose group. In pregnant women, four trials started supplementation at 12–16 weeks of gestation and continued until delivery, and six trials started supplementation at 20–28 weeks gestation and stopped it at delivery. The MD in 25(OH)D level reached was 8.6 (95% CI 5.3–11.9) ng/ml (p <0.001) comparing the high dose (3,662 IU/d) to the intermediate dose (1,836 IU/d), and 12.3 (95% CI 6.4–18.2) ng/ml (p <0.001), comparing the high dose (3,399 IU/d) to the low dose (375 IU/d). Comparing the intermediate (1,832 IU/d) to the low dose (301 IU/d), the MD in 25(OH)D level achieved was 7.8 (95% CI 4.5–10.8) ng/ml (p < 0.001). The proportion of pregnant women reaching a 25(OH)D level ≥ 20 ng/ml was 80–90%, 73% and 27–43% in the high, intermediate, and low dose groups, respectively. The risk of bias in the included studies, for children, adolescents and pregnant women, ranged from low to high. Conclusion In children, adolescents and pregnant women from the MENA, an intermediate vitamin D dose of 1,000–2,000 IU seems necessary to allow for the majority of the population to reach a desirable 25(OH)D level of 20 ng/ml. Further high quality RCTs are required to confirm/refute the beneficial impact of vitamin D supplementation on various clinically important outcomes. PMID:28403940
Older adults and high-risk medication administration in the emergency department
Kim, Mitchell; Mitchell, Steven H; Gatewood, Medley; Bennett, Katherine A; Sutton, Paul R; Crawford, Carol A; Bentov, Itay; Damodarasamy, Mamatha; Kaplan, Stephen J; Reed, May J
2017-01-01
Background Older adults are susceptible to adverse effects from opioids, nonsteroidal anti-inflammatory drugs (NSAIDs), and benzodiazepines (BZDs). We investigated factors associated with the administration of elevated doses of these medications of interest to older adults (≥65 years old) in the emergency department (ED). Patients and methods ED records were queried for the administration of medications of interest to older adults at two academic medical center EDs over a 6-month period. Frequency of recommended versus elevated (“High doses” were defined as doses that ranged between 1.5 and 3 times higher than the recommended starting doses; “very high doses” were defined as higher than high doses) starting doses of medications, as determined by geriatric pharmacy/medicine guidelines and expert consensus, was compared by age groups (65–69, 70–74, 75–79, 80–84, and ≥85 years), gender, and hospital. Results There were 17896 visits representing 11374 unique patients >65 years of age (55.3% men, 44.7% women). A total of 3394 doses of medications of interest including 1678 high doses and 684 very high doses were administered to 1364 different patients. Administration of elevated doses of medications was more common than that of recommended doses. Focusing on opioids and BZDs, the 65–69-year age group was much more likely to receive very high doses (1481 and 412 doses, respectively) than the ≥85-year age groups (relative risk [RR] 5.52, 95% CI 2.56–11.90), mainly reflecting elevated opioid dosing (RR 8.28, 95% CI 3.69–18.57). Men were more likely than women to receive very high doses (RR 1.47, 95% CI 1.26–1.72), primarily due to BZDs (RR 2.12, 95% CI 2.07–2.16). Conclusion Administration of elevated doses of opioids and BZDs in the older population occurs frequently in the ED, especially to the 65–69-year age group and men. Further attention to potentially unsafe dosing of high-risk medications to older adults in the ED is warranted. PMID:29184448
Kiefer, T; Krüger, W H; Schüler, F; Lotze, C; Hirt, C; Dölken, G
2006-06-01
Infections during neutropaenia contribute still significantly to mortality and morbidity after high-dose therapy and autologous stem cell transplantation. Further acceleration of haemopoietic recovery seems impossible for biological reasons. Another approach to shorten neutropaenia could be to remove drugs from high-dose therapy protocols with strong contribution to immunosuppression and neutropaenia and unproven antineoplastic activity. In this retrospective matched-pair analysis, conventional busulphan/cyclophosphamide (Bu/Cy) high-dose therapy was compared to single-agent busulphan conditioning before autologous stem cell transplantation. This modification led to a significant shorter neutropaenic interval by protraction of cell decrease and to a significant mitigation of neutropaenia. After single-agent busulphan conditioning, leucocytes dropped below 1/nl at median 1.5 days later when compared to the patients from the busulphanBu/Cy control group (P=0.001). In a significant percentage of patients (n=6, 60%) leucocytes did not fall below 0.5 cells/nl at any time. In contrast, all patients from the Bu/Cy control group experienced deep neutropaenia (P=0.004). Thrombocytopaenia and requirement for transfusions of platelets or red cells were not influenced. Antineoplastic activity seemed to be preserved as determined by survival analysis. In conclusion, modification of high-dose regimen with the intention to shorten neutropaenia with preserved antitumour activity could be an approach to reduce infection-related morbidity and mortality and to consider economic necessities.
Helium ion microscopy of graphene: beam damage, image quality and edge contrast
NASA Astrophysics Data System (ADS)
Fox, D.; Zhou, Y. B.; O'Neill, A.; Kumar, S.; Wang, J. J.; Coleman, J. N.; Duesberg, G. S.; Donegan, J. F.; Zhang, H. Z.
2013-08-01
A study to analyse beam damage, image quality and edge contrast in the helium ion microscope (HIM) has been undertaken. The sample investigated was graphene. Raman spectroscopy was used to quantify the disorder that can be introduced into the graphene as a function of helium ion dose. The effects of the dose on both freestanding and supported graphene were compared. These doses were then correlated directly to image quality by imaging graphene flakes at high magnification. It was found that a high magnification image with a good signal to noise ratio will introduce very significant sample damage. A safe imaging dose of the order of 1013 He+ cm-2 was established, with both graphene samples becoming highly defective at doses over 5 × 1014 He+ cm-2. The edge contrast of a freestanding graphene flake imaged in the HIM was then compared with the contrast of the same flake observed in a scanning electron microscope and a transmission electron microscope. Very strong edge sensitivity was observed in the HIM. This enhanced edge sensitivity over the other techniques investigated makes the HIM a powerful nanoscale dimensional metrology tool, with the capability of both fabricating and imaging features with sub-nanometre resolution.
Effects of aspirin and enoxaparin in a rat model of liver fibrosis.
Li, Chen-Jie; Yang, Zhi-Hui; Shi, Xiao-Liu; Liu, De-Liang
2017-09-21
To examine the effects of aspirin and enoxaparin on liver function, coagulation index and histopathology in a rat model of liver fibrosis. METHODS Forty-five male Sprague-Dawley rats were randomly divided into the control group (n = 5) and model group (n = 40). Thioacetamide (TAA) was used to induce liver fibrosis in the model group. TAA-induced fibrotic rats received TAA continuously (n = 9), TAA + low-dose aspirin (n = 9), TAA + high-dose aspirin (n = 9) or TAA + enoxaparin (n = 9) for 4 wk. All rats were euthanized after 4 wk, and both hematoxylin-eosin and Masson staining were performed to observe pathological changes in liver tissue. Liver fibrosis was assessed according to the METAVIR score. Compared with untreated cirrhotic controls, a significant improvement in fibrosis grade was observed in the low-dose aspirin, high-dose aspirin and enoxaparin treated groups, especially in the high-dose aspirin treated group. Alanine aminotransferase and total bilirubin were higher, albumin was lower and both prothrombin time and international normalized ratio were prolonged in the four treatment groups compared to controls. No significant differences among the four groups were observed. Aspirin and enoxaparin can alleviate liver fibrosis in this rat model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krayenbuehl, Jerome; Hartmann, Matthias; Lomax, Anthony J.
Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The meanmore » dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.« less
Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon
2010-02-01
A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tao, Yinghua; Chen, Guang-Hong; Hacker, Timothy A.
Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan wasmore » performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937.9% for the 500 mA FBP, 25 mA SIR, and 25 mA FBP, respectively. In numerical simulations, SIR mitigated streak artifacts in the low dose data and yielded flow maps with mean error <7% and standard deviation <9% of mean, for 30×30 pixel ROIs (12.9 × 12.9 mm{sup 2}). In comparison, low dose FBP flow errors were −38% to +258%, and standard deviation was 6%–93%. Additionally, low dose SIR achieved 4.6 times improvement in flow map CNR{sup 2} per unit input dose compared to low dose FBP. Conclusions: SIR reconstruction can reduce image noise and mitigate streaking artifacts caused by photon starvation in dynamic CT myocardial perfusion data sets acquired at low dose (low tube current), and improve perfusion map quality in comparison to FBP reconstruction at the same dose.« less
Furukawa, Takatoshi; Abe, Yasuhiro; Ito, Tsukasa; Kubota, Toshinori; Kakehata, Seiji
2017-02-01
Large-scale investigations have not been recently conducted on the efficacy of high-dose steroid administration of prednisolone (PSL) for Bell's palsy. We compared treatment results between normal-dose steroid (PSL 60 mg/d) and high-dose steroid (PSL 200 mg/d) + Hespander + Mannitol administration. We also investigated the recovery rate for antiviral agents. Retrospective case review. Tertiary referral center. A total of 675 patients with Bell's palsy who had grade V and grade VI on the House-Brackmann (HB) scale were treated in our department between 1995 and 2014. These patients could be divided into a normal-dose group and high-dose group. We separately assessed treatment outcomes for HB grade V patients and HB grade VI patients. Logistic regression analysis was also performed to investigate factors that can impact treatment outcomes, i.e., sex, age, days to start of treatment, PSL dosage, and antiviral drug administration. Recovery rates were significantly better in the high-dose steroid + Hespander + Mannitol group in comparison with the normal-dose steroid group for HB grade V (100% versus 77.7%) and HB grade VI (92.5% versus 68.2%). Additional effects of antiviral agents were only shown in the normal-dose group. Significant factors for treatment outcomes were PSL 200 mg/d administration and early initiation of treatment. Insignificant factors were sex, age, and the antiviral agent. We showed the high-dose steroid + Hespander + Mannitol administration produced significantly better outcomes than normal-dose steroid administration in the treatment of patients with Bell's palsy.
Chatelain, P; Job, J C; Blanchard, J; Ducret, J P; Oliver, M; Sagnard, L; Vanderschueren-Lodeweyckx, M
1994-06-01
This study reports the results of a 2-yr clinical trial with GH in 95 short prepubertal children with non-GH-deficient intrauterine growth retardation. This randomized, double blind, controlled study compared the effects of placebo (restricted to the first 6 months) and two doses of GH (0.4 and 1.2 IU/kg.week) given sc 6 days/week for 2 yr. A significant GH dose-dependent growth acceleration was observed. Mean height gain (SDS/CA) was 0.66 +/- 0.07 in group I (low dose, 0.4 IU/kg.week) compared to 1.25 +/- 0.07 in group II (high dose, 1.2 IU/kg.week). Mean bone maturation progression (expressed in months) was 26.2 +/- 1.7 and 30.2 +/- 1.5 over 24 months in groups I and II, respectively. Onset of puberty was observed in some patients of both groups. Whether chronic use of a high GH dose will advance the onset of puberty remains to be established. A great variability of growth acceleration was seen among GH dose groups, suggesting that factors in addition to GH dose might modulate individual responses to treatment. In conclusion, it is suggested that in these patients, dose-dependent catch-up growth could be induced by GH treatment.
Sykes, B W; Sykes, K M; Hallowell, G D
2014-07-01
Studies on omeprazole have reported that doses as low as 0.7 mg/kg bwt per os are potent suppressors of acid production. Yet, to date, no studies have compared treatment efficacy of different doses in clinical cases of equine gastric ulceration. Furthermore, no studies have been performed to compare the healing response of the squamous and glandular mucosa to acid suppression therapy. To compare: 1) the efficacy of 2 doses of omeprazole in the treatment of primary squamous and glandular gastric ulceration; and 2) the healing response of primary squamous and glandular gastric ulceration to acid suppression therapy. A blinded, randomised, dose-response clinical trial. Twenty Thoroughbred racehorses with grade ≥2/4 glandular ulceration were identified on gastroscopy. Seventeen horses also had grade ≥2/4 squamous ulceration. Horses were randomly assigned to one of 2 groups. Horses received either 2.0 g (high dose: 4.0 mg/kg bwt) or 0.8 g (low dose: 1.6 mg/kg bwt) of oral omeprazole per os once daily. Gastroscopy was repeated at 28-35 days. Time and dose significantly affected grades of squamous (P<0.0001, P = 0.02) and glandular (P = 0.006 and 0.005) ulceration. Data analysis did not support our hypothesis that the lower dose would have similar effects (i.e. be noninferior) to the higher dose when considering ulcer healing and ulcer improvement. Improvement was more likely with the high dose for the squamous (P = 0.05) but not glandular (P = 0.4) mucosa. The percentage of glandular ulcers that improved was less than squamous ulcers (P = 0.02). The results suggest that a dose-response exists for the treatment of both squamous and glandular ulcers. Improvement of glandular ulcers was not as complete as observed with squamous ulcers and current equine gastric ulcer syndrome treatment recommendations may not be appropriate for glandular disease. © 2013 EVJ Ltd.
Song, Chunmei; Du, Juan; Ge, Hongjuan
2015-07-01
To study the effects o Hippophae rhamnoides fruits on serum lipids and liver protection in high-fat-diet rats. Wistar rats were divided into 5 groups,including control group, high lipid model group and Hippophae rhamnoides low-, medium- and high- dose groups,every group wastaken high-fat diet except control group. The rats in control group and high lipid group were lavaged with physiological saline. The doses of Hippophae rhamnoides in low, middle and high groups were determined based on the 1x, 5x, and 10x standard human doses (50 g/60 kg BW), respectively. The rat were orally given test sample respectively for 28 days, once a day. Observed the changes of serum lipids and hepatic tissues pathology. Compared with the control group, the serum levels of total cholesterol (TC), triglyceride (TG) and low density lipoprotein cholesterol (LDL-C) were increased significantly (P < 0.05) in high-fat-diet rats. Compared with the high lipid group, Hippophae rhamnoides of different doses could significantly reduce the content of TG (P < 0.01). Hippophae rhamnoides reduced the tendency of TC and LDL-C in serum and reduced the fatty degeneration of liver cells. The Hippophae rhamnoides fruits can reduce the level of serum lipids and prevent the occurrence of fatty liver, can be used for the prevention of hyperlipidemia.
Proteomic and Epigenetic Analysis of Rice after Seed Spaceflight and Ground-Base Ion Radiations
NASA Astrophysics Data System (ADS)
Wang, Wei; Sun, Yeqing; Peng, Yuming; Zhao, Qian; Wen, Bin; Yang, Jun
Highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to plant seeds. In previous work, we compared the proteomic profiles of rice plants growing after seed spaceflights to ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) with mass spectrometry and found that the protein expression profiles were changed and differentially expressed proteins participated in most of the biological processes of rice. To further evaluate the dosage effects of space radiation and compare between low- and high-dose ion effects, we carried out three independent ground-base ionizing radiation experiments with different cumulative doses (low-dose range: 2~1000mGy, high-dose range: 2000~20000mGy) to rice seeds and performed proteomic analysis of seedlings. We found that protein expression profiles showed obvious boundaries between low- and high-dose radiation groups. Rates of differentially expressed proteins presented a dose-dependent effect, it reached the highest value at 2000mGy dosage point in all three radiation experiments coincidently; while proteins responded to low-dose radiations preferred to change their expressions at the minimum dosage (2mGy). Proteins participating in rice biological processes also responded differently between low- and high-dose radiations: proteins involved in energy metabolism and photosynthesis tended to be regulated after low-dose radiations while stress responding, protein folding and cell redox homeostasis related proteins preferred to change their expressions after high-dose radiations. By comparing the proteomic profiles between ground-base radiations and spaceflights, it was worth noting that ground-base low-dose ion radiation effects shared similar biological effects as space environment. In addition, we discovered that protein nucleoside diphosphate kinase 1 (NDPK1) showed obvious increased regulation after spaceflights and ion radiations. NDPK1 catalyzes nucleotide metabolism and is reported to be involved in DNA repair process. Its expression sensitivity and specificity were confirmed by RT-PCR and western blot analysis, indicating its potential to be used as space radiation biomarker. Space radiations might induce epigenetic effects on rice plants, especially changes of DNA methylation. Early results suggested that there were correlations between DNA methylation polymorphic and genomic mutation rates. In addition, the 5-methylcytosine located in coding gene’s promoter and exon regions could regulate gene expressions thus influence protein expressions. So whether there is correlation between genome DNA methylation changes and protein expression profile alterations caused by space radiation is worth for further investigation. Therefore we used the same rice samples treated by carbon ion radiation with different doses (0, 10, 20,100, 200, 1000, 2000, 5000, 20000mGy) and applied methylation sensitive amplification polymorphism (MSAP) for scanning genome DNA methylation changes. Interestingly, DNA methylation polymorphism rates also presented a dose-dependent effect and showed the same changing trend as rates of differentially expressed proteins. Whether there are correlations between epigenetic and proteomic effects of space radiation is worth for further investigation.
Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics
NASA Astrophysics Data System (ADS)
King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.
2011-03-01
The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.
Price, A K; de Godoy, M R C; Harper, T A; Knap, K E; Joslyn, S; Pietrzkowski, Z; Cross, B K; Detweiler, K B; Swanson, K S
2017-07-01
Our objective was to evaluate the short-term effects of calcium fructoborate (CFB) on gait, joint range of motion, serum inflammatory markers, and owner perception of pain in client-owned dogs. We used 59 osteoarthritic dogs with impairment, with dogs being randomly assigned to 4 treatments: placebo (60 mg fructose; = 15), low dose (69 mg CFB; = 14), high dose (127 mg CFB; = 14), or combination (69 mg CFB, 500 mg glucosamine hydrochloride and 200 mg chondroitin sulfate; = 16). Dogs up to 22.9 kg received 1 capsule/d, while dogs weighing 23 to 50 kg received 2 capsules/d. A physical examination, radiographs, goniometry measurements, gait analysis, blood sample collection, and a canine brief pain inventory questionnaire were performed on d 0 and 28. Change from baseline values were statistically analyzed among groups. After 28 d, dogs fed the low and high doses had an improved ( < 0.05) ability to rise from a lying position compared to placebo. Dogs fed the high dose also had a greater ( = 0.05) increase in soluble receptor for advanced glycation end products concentration than dogs fed the placebo. Sub-analysis of only large dogs (> 23 kg) showed that dogs fed the low dose had decreased ( < 0.05) pain severity score and pain at its worst compared to dogs fed the placebo. Large dogs fed the low dose also were shown to improve ( < 0.05) in their ability to rise from a lying position compared to dogs fed the placebo. Overall, CFB supplementation was well-tolerated and may aid in mitigating joint discomfort in dogs.
Taghizadeh, Mohsen; Memarzadeh, Mohammad Reza; Abedi, Fatemeh; Sharifi, Nasrin; Karamali, Fatemeh; Fakhrieh Kashan, Zohreh; Asemi, Zatollah
2016-08-01
Limited data are available regarding the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight subjects. The current study aimed to assess the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight. This randomized double-blind placebo-controlled clinical trial was conducted on 72 subjects with overweight, aged 18 - 50 years old. Participants were randomly divided into three groups: Group A received high-dose Cumin cyminum L. and lime capsules (75 mg each, n = 24), group B low-dose Cumin cyminum L. and lime capsules (25 mg each, n = 24) and group C placebos (n = 24) twice daily for eight weeks. After eight weeks of intervention, compared with low-dose C. cyminum L. plus lime and placebo, taking high-dose C. cyminum L. plus lime resulted in significant weight loss (in the high-dose group: -2.1 ± 1.7 vs. in the low-dose group: -1.2 ± 1.5 and in the placebo group: + 0.2 ± 1.3 kg, respectively; P < 0.001) and body mass index (-0.8 ± 0.6 vs. -0.5 ± 0.5 and +0.1 ± 0.5 kg/m 2 , respectively; P < 0.001). In addition, administration of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo, led to a significant reduction in fasting plasma glucose (FPG) (P < 0.001) and a significant rise in quantitative insulin sensitivity check index (QUICKI) (+ 0.02 ± 0.02 vs. + 0.01 ± 0.02 and 0.01 ± 0.01, respectively; P = 0.01). Moreover, a significant decrease in serum triglycerides (-14.1 ± 56.2 vs. +13.9 ± 36.8 and + 10.6 ± 25.1 mg/dL; respectively; P = 0.03), total-cholesterol (-18.4 ± 28.6 vs. +8.6 ± 28.5 and -1.0 ± 24.8 mg/dL; respectively; P = 0.004) and low density lipoproteins- (LDL)-cholesterol levels (-11.8 ± 20.7 vs. +6.5 ± 23.2 and -2.9 ± 20.4 mg/dL, respectively; P = 0.01) was observed following the consumption of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo. Results of the current study indicated that taking high-dose C. cyminum L. plus lime for eight weeks among subjects with overweight had beneficial effects on weight, BMI, FPG, QUICKI, triglycerides, total-cholesterol and LDL-cholesterol levels.
Taghizadeh, Mohsen; Memarzadeh, Mohammad Reza; Abedi, Fatemeh; Sharifi, Nasrin; Karamali, Fatemeh; Fakhrieh Kashan, Zohreh; Asemi, Zatollah
2016-01-01
Background Limited data are available regarding the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight subjects. Objectives The current study aimed to assess the effects of combined administration of Cumin cyminum L. and lime on weight loss and metabolic profiles among subjects with overweight. Patients and Methods This randomized double-blind placebo-controlled clinical trial was conducted on 72 subjects with overweight, aged 18 - 50 years old. Participants were randomly divided into three groups: Group A received high-dose Cumin cyminum L. and lime capsules (75 mg each, n = 24), group B low-dose Cumin cyminum L. and lime capsules (25 mg each, n = 24) and group C placebos (n = 24) twice daily for eight weeks. Results After eight weeks of intervention, compared with low-dose C. cyminum L. plus lime and placebo, taking high-dose C. cyminum L. plus lime resulted in significant weight loss (in the high-dose group: -2.1 ± 1.7 vs. in the low-dose group: -1.2 ± 1.5 and in the placebo group: + 0.2 ± 1.3 kg, respectively; P < 0.001) and body mass index (-0.8 ± 0.6 vs. -0.5 ± 0.5 and +0.1 ± 0.5 kg/m2, respectively; P < 0.001). In addition, administration of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo, led to a significant reduction in fasting plasma glucose (FPG) (P < 0.001) and a significant rise in quantitative insulin sensitivity check index (QUICKI) (+ 0.02 ± 0.02 vs. + 0.01 ± 0.02 and 0.01 ± 0.01, respectively; P = 0.01). Moreover, a significant decrease in serum triglycerides (-14.1 ± 56.2 vs. +13.9 ± 36.8 and + 10.6 ± 25.1 mg/dL; respectively; P = 0.03), total-cholesterol (-18.4 ± 28.6 vs. +8.6 ± 28.5 and -1.0 ± 24.8 mg/dL; respectively; P = 0.004) and low density lipoproteins- (LDL)-cholesterol levels (-11.8 ± 20.7 vs. +6.5 ± 23.2 and -2.9 ± 20.4 mg/dL, respectively; P = 0.01) was observed following the consumption of high-dose C. cyminum L. plus lime compared with low-dose C. cyminum L. plus lime and placebo. Conclusions Results of the current study indicated that taking high-dose C. cyminum L. plus lime for eight weeks among subjects with overweight had beneficial effects on weight, BMI, FPG, QUICKI, triglycerides, total-cholesterol and LDL-cholesterol levels. PMID:27781121
Gielkens, H A; van den Biggelaar, A; Vecht, J; Onkenhout, W; Lamers, C B; Masclee, A A
1999-02-01
Patients on total parenteral nutrition have an increased risk of developing gallstones because of gall bladder hypomotility. High dose amino acids may prevent biliary stasis by stimulating gall bladder emptying. To investigate whether intravenous amino acids also influence antroduodenal motility. Eight healthy volunteers received, on three separate occasions, intravenous saline (control), low dose amino acids (LDA), or high dose amino acids (HDA). Antroduodenal motility was recorded by perfusion manometry and duodenocaecal transit time (DCTT) using the lactulose breath hydrogen test. DCTT was significantly prolonged during LDA and HDA treatment compared with control. The interdigestive motor pattern was maintained and migrating motor complex (MMC) cycle length was significantly reduced during HDA compared with control and LDA due to a significant reduction in phase II duration. Significantly fewer phase IIIs originated in the gastric antrum during LDA and HDA compared with control. Duodenal phase II motility index was significantly reduced during HDA, but not during LDA, compared with control. Separate intravenous infusion of high doses of amino acids in healthy volunteers: (1) modulates interdigestive antroduodenal motility; (2) shortens MMC cycle length due to a reduced duration of phase II with a lower contractile incidence both in the antrum and duodenum (phase I remains unchanged whereas the effect on phase III is diverse: in the antrum phase III is suppressed and in the duodenum the frequency is increased); and (3) prolongs interdigestive DCTT.
A novel method for interactive multi-objective dose-guided patient positioning
NASA Astrophysics Data System (ADS)
Haehnle, Jonas; Süss, Philipp; Landry, Guillaume; Teichert, Katrin; Hille, Lucas; Hofmaier, Jan; Nowak, Dimitri; Kamp, Florian; Reiner, Michael; Thieke, Christian; Ganswindt, Ute; Belka, Claus; Parodi, Katia; Küfer, Karl-Heinz; Kurz, Christopher
2017-01-01
In intensity-modulated radiation therapy (IMRT), 3D in-room imaging data is typically utilized for accurate patient alignment on the basis of anatomical landmarks. In the presence of non-rigid anatomical changes, it is often not obvious which patient position is most suitable. Thus, dose-guided patient alignment is an interesting approach to use available in-room imaging data for up-to-date dose calculation, aimed at finding the position that yields the optimal dose distribution. This contribution presents the first implementation of dose-guided patient alignment as multi-criteria optimization problem. User-defined clinical objectives are employed for setting up a multi-objective problem. Using pre-calculated dose distributions at a limited number of patient shifts and dose interpolation, a continuous space of Pareto-efficient patient shifts becomes accessible. Pareto sliders facilitate interactive browsing of the possible shifts with real-time dose display to the user. Dose interpolation accuracy is validated and the potential of multi-objective dose-guided positioning demonstrated for three head and neck (H&N) and three prostate cancer patients. Dose-guided positioning is compared to replanning for all cases. A delineated replanning CT served as surrogate for in-room imaging data. Dose interpolation accuracy was high. Using a 2 % dose difference criterion, a median pass-rate of 95.7% for H&N and 99.6% for prostate cases was determined in a comparison to exact dose calculations. For all patients, dose-guided positioning allowed to find a clinically preferable dose distribution compared to bony anatomy based alignment. For all H&N cases, mean dose to the spared parotid glands was below 26~\\text{Gy} (up to 27.5~\\text{Gy} with bony alignment) and clinical target volume (CTV) {{V}95 % } above 99.1% (compared to 95.1%). For all prostate patients, CTV {{V}95 % } was above 98.9% (compared to 88.5%) and {{V}50~\\text{Gy}} to the rectum below 50 % (compared to 56.1%). Replanning yielded improved results for the H&N cases. For the prostate cases, differences to dose-guided positioning were minor.
Tulloch, Simon J; Zhang, Yuxin; McLean, Angus; Wolf, Kathleen N
2002-11-01
To assess the bioavailability of three test formulations of a single dose of extended-release Adderall 20-mg capsules compared with two doses of immediate-release Adderall 10-mg tablets, and to assess the bioequivalence of a single 30-mg dose of the chosen extended-release Adderall formulation (designated as SLI381) administered in applesauce (sprinkled) and the same dose administered as an intact capsule with or without food. Randomized, open-label, crossover study. Clinical research unit. Forty-one healthy adults. Study A had four treatment sequences: three test formulations (A, B, and C) of a single dose of extended-release Adderall 20 mg, and two 10-mg doses of Adderall given 4 hours apart. Study B had three treatment sequences: a single dose of SLI381 30 mg as an intact capsule after overnight fast, an intact capsule after a high-fat breakfast, and the contents of a capsule sprinkled in 1 tablespoon of applesauce. The 20-mg test formulation A had comparable pharmacokinetic profiles and bioequivalence in rate and extent of drug absorption to Adderall 10 mg twice/day for both d- and l-amphetamine. Formulations B and C had statistically significant differences from the reference drug in some pharmacokinetic parameters. A 30-mg dose of SLI381 showed no significant differences in rate and extent of absorption of d- and l-amphetamine for fasted or sprinkled conditions compared with the high-fat meal condition. SLI381 20 mg/day is bioequivalent to Adderall 10 mg twice/day. SLI381 30 mg administered in applesauce is bioequivalent in terms of both rate and extent of absorption to the same dose administered as an intact capsule in both fasted and fed states.
Deist, T M; Gorissen, B L
2016-02-07
High-dose-rate brachytherapy is a tumor treatment method where a highly radioactive source is brought in close proximity to the tumor. In this paper we develop a simulated annealing algorithm to optimize the dwell times at preselected dwell positions to maximize tumor coverage under dose-volume constraints on the organs at risk. Compared to existing algorithms, our algorithm has advantages in terms of speed and objective value and does not require an expensive general purpose solver. Its success mainly depends on exploiting the efficiency of matrix multiplication and a careful selection of the neighboring states. In this paper we outline its details and make an in-depth comparison with existing methods using real patient data.
Estimation of the Dose and Dose Rate Effectiveness Factor
NASA Technical Reports Server (NTRS)
Chappell, L.; Cucinotta, F. A.
2013-01-01
Current models to estimate radiation risk use the Life Span Study (LSS) cohort that received high doses and high dose rates of radiation. Transferring risks from these high dose rates to the low doses and dose rates received by astronauts in space is a source of uncertainty in our risk calculations. The solid cancer models recommended by BEIR VII [1], UNSCEAR [2], and Preston et al [3] is fitted adequately by a linear dose response model, which implies that low doses and dose rates would be estimated the same as high doses and dose rates. However animal and cell experiments imply there should be curvature in the dose response curve for tumor induction. Furthermore animal experiments that directly compare acute to chronic exposures show lower increases in tumor induction than acute exposures. A dose and dose rate effectiveness factor (DDREF) has been estimated and applied to transfer risks from the high doses and dose rates of the LSS cohort to low doses and dose rates such as from missions in space. The BEIR VII committee [1] combined DDREF estimates using the LSS cohort and animal experiments using Bayesian methods for their recommendation for a DDREF value of 1.5 with uncertainty. We reexamined the animal data considered by BEIR VII and included more animal data and human chromosome aberration data to improve the estimate for DDREF. Several experiments chosen by BEIR VII were deemed inappropriate for application to human risk models of solid cancer risk. Animal tumor experiments performed by Ullrich et al [4], Alpen et al [5], and Grahn et al [6] were analyzed to estimate the DDREF. Human chromosome aberration experiments performed on a sample of astronauts within NASA were also available to estimate the DDREF. The LSS cohort results reported by BEIR VII were combined with the new radiobiology results using Bayesian methods.
Rathi, N K; Tanner, A R; Dinh, A; Dong, W; Feng, L; Ensor, J; Wallace, S K; Haque, S A; Rondon, G; Price, K J; Popat, U; Nates, J L
2015-03-01
Diffuse alveolar hemorrhage (DAH) is a poorly understood complication of transplantation carrying a high mortality. Patients commonly deteriorate and require intensive care unit (ICU) admission. Treatment with high-dose steroids and aminocaproic acid (ACA) has been suggested. The current study examined 119 critically ill adult hematopoietic transplant patients treated for DAH. Patients were subdivided into low-, medium- and high-dose steroid groups with or without ACA. All groups had similar baseline characteristics and severity of illness scores. Primary objectives were 30, 60, 100 day, ICU and hospital mortality. Overall mortality (n=119) on day 100 was high at 85%. In the steroids and ACA cohort (n=82), there were no significant differences in 30, 60, 100, day, ICU and hospital mortality between the dosing groups. In the steroids only cohort (n=37), the low-dose steroid group had a lower ICU and hospital mortality (P=0.02). Adjunctive treatment with ACA did not produce differences in outcomes. In the multivariate analysis, medium- and high-dose steroids were associated with a higher ICU mortality (P=0.01) as compared with the low-dose group. Our data suggest that treatment strategies may need to be reanalyzed to avoid potentially unnecessary and potentially harmful therapies.
Cho, Oyeon; Chun, Mison; Oh, Young-Taek; Noh, O Kyu; Chang, Suk-Joon; Ryu, Hee-Sug; Lee, Eun Ju
2017-10-01
Radioresistance often leads to poor survival in concurrent chemoradiotherapy-treated cervical squamous cell carcinoma, and reliable biomarkers can improve prognosis. We compared the prognostic potential of hemoglobin, absolute neutrophil count, and absolute lymphocyte count with that of squamous cell carcinoma antigen in concurrent chemoradiotherapy-treated squamous cell carcinoma. We analyzed 152 patients with concurrent chemoradiotherapy and high-dose-rate intracavitary brachytherapy-treated cervical squamous cell carcinoma. Hemoglobin, absolute neutrophil count, absolute lymphocyte count, and squamous cell carcinoma antigen were quantitated and correlated with survival, using Cox regression, receiver operating characteristic curve analysis, and Kaplan-Meier plots. Both hemoglobin and absolute lymphocyte count in the second week of concurrent chemoradiotherapy (Hb2 and ALC2) and squamous cell carcinoma antigen in the third week of concurrent chemoradiotherapy (mid-squamous cell carcinoma antigen) correlated significantly with disease-specific survival and progression-free survival. The ratio of high-dose-rate intracavitary brachytherapy dose to total dose (high-dose-rate intracavitary brachytherapy ratio) correlated significantly with progression-free survival. Patients with both low Hb2 (≤11 g/dL) and ALC2 (≤639 cells/µL) showed a lower 5-year disease-specific survival rate than those with high Hb2 and/or ALC2, regardless of mid-squamous cell carcinoma antigen (mid-squamous cell carcinoma antigen: ≤4.7 ng/mL; 5-year disease-specific survival rate: 85.5% vs 94.6%, p = 0.0096, and mid-squamous cell carcinoma antigen: >4.7 ng/mL; 5-year disease-specific survival rate: 43.8% vs 66.7%, p = 0.192). When both Hb2 and ALC2 were low, the low high-dose-rate intracavitary brachytherapy ratio (≤0.43) subgroup displayed significantly lower 5-year disease-specific survival rate compared to the subgroup high high-dose-rate intracavitary brachytherapy ratio (>0.43) (62.5% vs 88.2%, p = 0.0067). Patients with both anemia and lymphopenia during concurrent chemoradiotherapy showed poor survival, independent of mid-squamous cell carcinoma antigen, and escalating high-dose-rate intracavitary brachytherapy ratio might improve survival.
Gao, Yuan; Song, Lin-Xuan; Jiang, Miao-Na; Ge, Guang-Yan; Jia, Yu-Jie
2008-04-01
The aim of this research is to study the effects of traditional Chinese medicine on endotoxin and its receptors in rats with nonalcoholic steatohepatitis (NASH). Fifty-six SD rats were divided into seven groups. All the animals were fed high fatty diet for 12 weeks. Rats with non-alcoholic steatohepatitis (NASH) were treated with traditional Chinese medicine according to low-dose, middle-dose, high-dose and Lipitor from fifth week. All rats were killed at the end of 12th week. The liver pathology changes were observed under light microscope. The levels of serum lipoid, alanine aminotransferase (ALT), endotoxin (ET), tumor necrosis factor-alpha (TNF-alpha) and interleukine-1beta (IL-1beta) were determined. The expressions of CD14 and nuclear transcriptional factor kappaB (NF-kappaB) were observed by immunohistochemistry. The expressions of lipopolysaccharide binding protein (LBP), toll-like receptor-4 (TLR-4), myeloid differentiation-2 (MD-2) and induced nitric oxide synthase (iNOS) mRNA were detected by the reverse transcription polymerase chain reaction (RT-PCR). The levels of serum endotoxin in the middle dose group (0.0225 +/- 0.0112 EU/l) were lower than those in high fatty diet model group (0.2249 +/- 0.0982 EU/l) at 12th week, the difference was significant (P < 0.01). In the middle dose group, mean values of serum TNF-alpha and IL-1beta levels decreased dramatically (1.604 +/- 0.302 ng/ml and 0.052 +/- 0.024 ng/ml) compared with those in the high fatty diet model group (4.029 +/- 1.180 ng/ml and 14.944 +/- 0.491 ng/ml; P < 0.01 and P < 0.01). The expressions of CD14 and NF-kappaB in the middle dose group decreased compared with those in the high fatty diet model group. The expressions of LBP mRNA (0.284 +/- 0.105) and TLR-4 mRNA (0.290 +/- 0.123) in the middle dose group down regulated compared with those in the high fatty diet model group (1.060 +/- 0.158 and 1.261 +/- 0.368; P < 0.01 and P < 0.01). In the middle dose group MD-2 and iNOS gene expressions were 0.132 +/- 0.058 and 0.164 +/- 0.061, respectively, which were significantly lower compared with the high fatty diet model group (0.795 +/- 0.294 and 1.029 +/- 0.388; P < 0.01 and P < 0.01). The mechanism of non-alcoholic steatohepatitis (NASH) maybe related to increasing the levels of serum endotoxin, upregulating endotoxin receptors of hepatic tissue and enhancing liver inflammatory injury. Traditional Chinese medicine is a good treatment for non-alcoholic steatohepatitis (NASH). It can produce a marked effect via relieving LPS-induced liver injury.
Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla
2014-01-01
Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.
Cheng, Ji-Wei; Zhang, Xiao-Jing; Cheng, Li-Shan; Li, Guo-Yi; Zhang, Li-Jun; Ji, Kang-Xiang; Zhao, Qing; Bai, Yu
2018-02-01
Intravenous thrombolysis using tissue plasminogen activator (tPA) improves significantly the neurologic function in patients with acute ischemic stroke (AIS). However, it brings financial burden to patients and is associated with symptomatic intracranial hemorrhage (SICH). Whether low-dose tPA can effectively reduce SICH and has the same efficacy as standard-dose tPA is still controversial. We searched for English clinical trials published before March, 2017on the comparison of the efficacy and safety between low and standard dose of tPA in the treatment of AIS using MEDLINE, Embase, and Cochrane Library. The modified Rankin scale (mRS) score was used as the primary efficacy outcome. The mRS1 corresponded to 0-1, whereas mRS2 corresponded to 0-2. The SICH and mortality were adopted as primary safety outcomes. Twelve high-quality studies were selected, including 7686 patients (low-dose: 2888, standard-dose: 4798). With no statistical heterogeneity, the fixed effects model was adopted in the analysis. Similarly to standard doses, low-dose tPA improved the mRS scores (mRS1: odds ratio [OR] = .92, 95% confidence interval [CI] .84-1.02; P = .12; mRS2: OR = .97, 95% CI .88-1.08; P = .57). Compared with standard-dose tPA, low-dose tPA reduced the incidence of SICH (by National Institute of Neurological Disorders and Stroke [NINDS] definition: OR = .71, 95% CI .57-0.89; P = .003; by Safe Implementation of Thrombolysis in Stroke Monitoring Study [SITS-MOST] definition: OR = .64, 95% CI .42-0.99; P = .04), while both reduced mortality (OR = .87, 95% CI .74-1.02; P = .08). Low-dose tPA is comparable to standard-dose tPA in improving the neurologic function and reducing mortality in AIS patients. Moreover, low-dose tPA can reduce the incidence of SICH compared with standard-dose tPA. Therefore, low-dose tPA is highly recommended in AIS patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Iron deficiency and iron excess damage mitochondria and mitochondrial DNA in rats
Walter, Patrick B.; Knutson, Mitchell D.; Paler-Martinez, Andres; Lee, Sonia; Xu, Yu; Viteri, Fernando E.; Ames, Bruce N.
2002-01-01
Approximately two billion people, mainly women and children, are iron deficient. Two studies examined the effects of iron deficiency and supplementation on rats. In study 1, mitochondrial functional parameters and mitochondrial DNA (mtDNA) damage were assayed in iron-deficient (≤5 μg/day) and iron-normal (800 μg/day) rats and in both groups after daily high-iron supplementation (8,000 μg/day) for 34 days. This dose is equivalent to the daily dose commonly given to iron-deficient humans. Iron-deficient rats had lower liver mitochondrial respiratory control ratios and increased levels of oxidants in polymorphonuclear-leukocytes, as assayed by dichlorofluorescein (P < 0.05). Rhodamine 123 fluorescence of polymorphonuclear-leukocytes also increased (P < 0.05). Lowered respiratory control ratios were found in daily high-iron-supplemented rats regardless of the previous iron status (P < 0.05). mtDNA damage was observed in both iron-deficient rats and rats receiving daily high-iron supplementation, compared with iron-normal rats (P < 0.05). Study 2 compared iron-deficient rats given high doses of iron (8,000 μg) either daily or every third day and found that rats given iron supplements every third day had less mtDNA damage on the second and third day after the last dose compared to daily high iron doses. Both inadequate and excessive iron (10 × nutritional need) cause significant mitochondrial malfunction. Although excess iron has been known to cause oxidative damage, the observation of oxidant-induced damage to mitochondria from iron deficiency has been unrecognized previously. Untreated iron deficiency, as well as excessive-iron supplementation, are deleterious and emphasize the importance of maintaining optimal iron intake. PMID:11854522
DOE Office of Scientific and Technical Information (OSTI.GOV)
Best, R; Harrell, A; Geesey, C
2014-06-15
Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parametersmore » of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.« less
Randomized comparison of 5 and 10 microgram doses of two recombinant hepatitis B vaccines.
Bryan, J P; Craig, P G; Reyes, L; Hakre, S; Jaramillo, R; Harlan, H; MacArthy, P; Legters, L J
1995-08-01
The high cost of hepatitis B vaccines remains an obstacle to their use. Since the recommended adult dose of Recombivax HB (MSD) is 10 micrograms and that of Engerix B (SKB) is 20 micrograms, we sought to determine if 10 microgram doses of each vaccine are equally immunogenic. Further, since 5 microgram doses of Recombivax are routinely used in those < or = 29 years of age in the US military, we sought to compare this dose with 5 microgram doses of Engerix B. Lower doses of Engerix would result in vaccine cost savings. members of the Belize Defence Force who were > or = 18 years of age (median 24) without detectable anti-HBc were randomly assigned to receive Recombivax, 5 or 10 micrograms, or ENgerix, 5 or 10 micrograms IM at 0, 1, and 6 months. Randomization was weighted toward Engerix. after 3 doses, geometric mean concentrations (GMC) of anti-HBs were highest among those receiving Recombivax 10 micrograms (n=22) or 5 micrograms (n=46) with GMC anti-HBs of 744 and 570 mIU ml-1, respectively. Similar proportions in the two groups developed > or = 10 mIU m-1 anti-HBs (100 and 98%). Among the 91 people who received Engerix 10 micrograms, the GMC anti-HBs was 325 mIU ml-1 and 91% developed > or = 10 mIU ml-1. The 87 people who received Engerix 5 micrograms had the lowest GMC, 177 mIU ml-1 (p < 0.05 compared with either Recombivax group). Only 86% attained > or = 10 mIU ml-1 anti-HBs (p > 0.05 compared with other regimens). The proportion attaining > or = 100 mIU ml-1 was lower in the 5 microgram Engerix group (63%) compared with 80% in the 5 microgram or 95% in the 10 microgram Recombivax groups (p < 0.05). Engerix administered in 5 microgram doses is less immunogenic than 5 or 10 microgram doses of Recombivax. In healthy populations < 30 years of age, regimens of half the recommended adult dose (5 micrograms of Recombivax or 10 micrograms of Engerix) are highly immunogenic and may result in significant vaccine cost savings.
Optimizing bevacizumab dosing in glioblastoma: less is more.
Ajlan, Abdulrazag; Thomas, Piia; Albakr, Abdulrahman; Nagpal, Seema; Recht, Lawrence
2017-10-01
Compared to traditional chemotherapies, where dose limiting toxicities represent the maximum possible dose, monoclonal antibody therapies are used at doses well below maximum tolerated dose. However, there has been little effort to ascertain whether there is a submaximal dose at which the efficacy/complication ratio is maximized. Thus, despite the general practice of using Bevacizumab (BEV) at dosages of 10 mg/kg every other week for glioma patients, there has not been much prior work examining whether the relatively high complication rates reported with this agent can be decreased by lowering the dose without impairing efficacy. We assessed charts from 80 patients who received BEV for glioblastoma to survey the incidence of complications relative to BEV dose. All patients were treated with standard upfront chemoradiation. The toxicity was graded based on the NCI CTCAE, version 4.03. The rate of BEV serious related adverse events was 12.5% (n = 10/80). There were no serious adverse events (≥grade 3) when the administered dose was (<3 mg/kg/week), compared to a 21% incidence in those who received higher doses (≥3 mg/kg/week) (P < 0.01). Importantly, the three patient deaths attributable to BEV administration occurred in patients receiving higher doses. Patients who received lower doses also had a better survival rate, although this did not reach statistical significance [median OS 39 for low dose group vs. 17.3 for high dose group (P = 0.07)]. Lower rates of serious BEV related toxicities are noted when lower dosages are used without diminishing positive clinical impact. Further work aimed at optimizing BEV dosage is justified.
Cosmic Radiation Exposure of Future Hypersonic Flight Missions.
Koops, L
2017-06-15
Cosmic radiation exposure in air traffic grows with flight altitude, geographical latitude and flight time. For future high-speed intercontinental point-to-point travel, the trade-off between reduced flight time and enhanced dose rate at higher flight altitudes is investigated. Various representative (partly) hypersonic cruise missions are considered and in dependence on solar activity the integral route dose is calculated for envisaged flight profiles and trajectories. Our results are compared to those for corresponding air connections served by present day subsonic airliners. During solar maximum, we find a significant reduction in route dose for all considered high-speed missions compared to the subsonic reference. However, during solar minimum, comparable or somewhat larger doses result on transpolar trajectories with (partly) hypersonic cruise at Mach 5. Both solar activity and routing are hence found to determine, whether passengers can profit from shorter flight times in terms of radiation exposure, despite of altitude-induced higher dose rates. Yet, aircrews with fixed number of block hours are always subject to larger annual doses, which in the considered cases take values up to five times the reference. We comment on the implications of our results for route planning and aviation decision-making in the absence of radiation shielding solutions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A
2018-01-01
Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level ("standard") support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282.
Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A
2017-01-01
Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level (“standard”) support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282 PMID:29020861
Hybrid dose calculation: a dose calculation algorithm for microbeam radiation therapy
NASA Astrophysics Data System (ADS)
Donzelli, Mattia; Bräuer-Krisch, Elke; Oelfke, Uwe; Wilkens, Jan J.; Bartzsch, Stefan
2018-02-01
Microbeam radiation therapy (MRT) is still a preclinical approach in radiation oncology that uses planar micrometre wide beamlets with extremely high peak doses, separated by a few hundred micrometre wide low dose regions. Abundant preclinical evidence demonstrates that MRT spares normal tissue more effectively than conventional radiation therapy, at equivalent tumour control. In order to launch first clinical trials, accurate and efficient dose calculation methods are an inevitable prerequisite. In this work a hybrid dose calculation approach is presented that is based on a combination of Monte Carlo and kernel based dose calculation. In various examples the performance of the algorithm is compared to purely Monte Carlo and purely kernel based dose calculations. The accuracy of the developed algorithm is comparable to conventional pure Monte Carlo calculations. In particular for inhomogeneous materials the hybrid dose calculation algorithm out-performs purely convolution based dose calculation approaches. It is demonstrated that the hybrid algorithm can efficiently calculate even complicated pencil beam and cross firing beam geometries. The required calculation times are substantially lower than for pure Monte Carlo calculations.
Vitamin E reduces hepatic fibrosis in mice with Schistosoma japonicum infection.
Wang, Xuefeng; Zhang, Rongbo; Du, Jiuwei; Hu, Youying; Xu, Lifa; Lu, Jun; Ye, Song
2012-02-01
To investigate whether vitamin E protects against hepatic fibrosis in mice with Schistosoma japonicum infection, 24 pathogen-free Kunming mice were selected and randomly divided into four groups: control (uninfected, untreated), model (infected, untreated), low-dose intervention (infected, vitamin E-treated, 30 mg/g bodyweight/day) and high-dose intervention (infected, vitamin E-treated, 60 mg/g bodyweight/day). Mice were infected with Schistosoma japonicum by inoculating abdominal skin with snail hosts. The activities of malondialdehyde (MDA), superoxide dismutase (SOD), glutathione peroxidase (GPx) and catalase (CAT) were detected in hepatic tissue by colorimetry. The expression levels of laminin (LN), hyaluronic acid (HA), procollagen type Ⅲ (PC-III) and type Ⅳ collagen (IV-C) were detected in the serum by radioimmunoassay. Finally, areas and numbers of granulomas were assessed through histopathology 42 days following treatment. The results revealed that mean areas of granulomas were smaller in the low- and high-dose intervention groups compared to those in the model group. Furthermore, the higher dose of vitamin E resulted in smaller granulomas than the low dose. The levels of LN, HA, PC-III and IV-C in the serum were lower following vitamin E treatment than in the model group. By contrast, activity of SOD, GPx and CAT in hepatic tissue was higher following vitamin E treatment compared to the model group. The activity of MDA was lower in hepatic tissue following vitamin E treatment compared to the model group, but was higher compared to controls. In general, the higher dose of vitamin E affected measurements to a greater extent than the lower dose. In conclusion, vitamin E treatment may reduce the growth of granulomas, slowing the process of hepatic fibrosis, and this effect may be the result of the altered activity of the oxidation-reduction enzyme system.
2012-01-01
Background Shivering and fever are common side effects of misoprostol. An unexpectedly high rate of fever above 40°C was documented among Ecuadorian women given treatment with 800mcg of sublingual misoprostol to manage postpartum hemorrhage (PPH) (36%). Much lower rates have been reported elsewhere (0-9%). Methods From February to July 2010, an open-label pilot study was conducted in Quito, Ecuador to determine whether a lower dose--600mcg sublingual misoprostol--would result in a lower incidence of high fever (≥40°C). Rates of shivering and fever with 600mcg sublingual regimen were compared to previously documented rates in Ecuador following PPH treatment with 800mcg sublingual misoprostol. Results The 600mcg dose resulted in a 55% lower rate of high fever compared with the 800mcg regimen (8/50; 16% vs. 58/163; 36%; relative risk 0.45 95% CI 0.23-0.88). Only one woman had severe shivering following the 600mcg dose compared with 19 women in the 800mcg cohort (2% vs. 12%; relative risk 0.17 (0.02-1.25)). No cases of delirium/altered sensorium were reported with the 600mcg dose and women’s assessment of severity/tolerability of shivering and fever was better with the lower dose. Conclusions 600mcg sublingual misoprostol was found to decrease the occurrence of high fever among Ecuadorian women when given to treat PPH. This study however was not powered to examine the efficacy of this treatment regimen and cannot be recommended at this time. Future research is needed to confirm whether other populations, outside of Quito, Ecuador, experience unusually high rates of elevated body temperature following sublingual administration of misoprostol for treatment of PPH. If indeed similar trends are found elsewhere, larger trials to confirm the efficacy of lower dosages may be justified. Trial Registration Clinical trials.gov, Registry No. NCT01080846 PMID:22769055
León, Wilfrido; Durocher, Jill; Barrera, Gustavo; Pinto, Ernesto; Winikoff, Beverly
2012-07-07
Shivering and fever are common side effects of misoprostol. An unexpectedly high rate of fever above 40°C was documented among Ecuadorian women given treatment with 800mcg of sublingual misoprostol to manage postpartum hemorrhage (PPH) (36%). Much lower rates have been reported elsewhere (0-9%). From February to July 2010, an open-label pilot study was conducted in Quito, Ecuador to determine whether a lower dose--600mcg sublingual misoprostol--would result in a lower incidence of high fever (≥40°C). Rates of shivering and fever with 600mcg sublingual regimen were compared to previously documented rates in Ecuador following PPH treatment with 800mcg sublingual misoprostol. The 600mcg dose resulted in a 55% lower rate of high fever compared with the 800mcg regimen (8/50; 16% vs. 58/163; 36%; relative risk 0.45 95% CI 0.23-0.88). Only one woman had severe shivering following the 600mcg dose compared with 19 women in the 800mcg cohort (2% vs. 12%; relative risk 0.17 (0.02-1.25)). No cases of delirium/altered sensorium were reported with the 600mcg dose and women's assessment of severity/tolerability of shivering and fever was better with the lower dose. 600mcg sublingual misoprostol was found to decrease the occurrence of high fever among Ecuadorian women when given to treat PPH. This study however was not powered to examine the efficacy of this treatment regimen and cannot be recommended at this time. Future research is needed to confirm whether other populations, outside of Quito, Ecuador, experience unusually high rates of elevated body temperature following sublingual administration of misoprostol for treatment of PPH. If indeed similar trends are found elsewhere, larger trials to confirm the efficacy of lower dosages may be justified. Clinical trials.gov, Registry No. NCT01080846.
Taguchi, Isao; Iimuro, Satoshi; Iwata, Hiroshi; Takashima, Hiroaki; Abe, Mitsuru; Amiya, Eisuke; Ogawa, Takanori; Ozaki, Yukio; Sakuma, Ichiro; Nakagawa, Yoshihisa; Hibi, Kiyoshi; Hiro, Takafumi; Fukumoto, Yoshihiro; Hokimoto, Seiji; Miyauchi, Katsumi; Yamazaki, Tsutomu; Ito, Hiroshi; Otsuji, Yutaka; Kimura, Kazuo; Takahashi, Jun; Hirayama, Atsushi; Yokoi, Hiroyoshi; Kitagawa, Kazuo; Urabe, Takao; Okada, Yasushi; Terayama, Yasuo; Toyoda, Kazunori; Nagao, Takehiko; Matsumoto, Masayasu; Ohashi, Yasuo; Kaneko, Tetsuji; Fujita, Retsu; Ohtsu, Hiroshi; Ogawa, Hisao; Daida, Hiroyuki; Shimokawa, Hiroaki; Saito, Yasushi; Kimura, Takeshi; Inoue, Teruo; Matsuzaki, Masunori; Nagai, Ryozo
2018-05-08
Current guidelines call for high-intensity statin therapy in patients with cardiovascular disease on the basis of several previous "more versus less statins" trials. However, no clear evidence for more versus less statins has been established in an Asian population. In this prospective, multicenter, randomized, open-label, blinded end point study, 13 054 Japanese patients with stable coronary artery disease who achieved low-density lipoprotein cholesterol (LDL-C) <120 mg/dL during a run-in period (pitavastatin 1 mg/d) were randomized in a 1-to-1 fashion to high-dose (pitavastatin 4 mg/d; n=6526) or low-dose (pitavastatin 1 mg/d; n=6528) statin therapy. The primary end point was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal ischemic stroke, or unstable angina requiring emergency hospitalization. The secondary composite end point was a composite of the primary end point and clinically indicated coronary revascularization excluding target-lesion revascularization at sites of prior percutaneous coronary intervention. The mean age of the study population was 68 years, and 83% were male. The mean LDL-C level before enrollment was 93 mg/dL with 91% of patients taking statins. The baseline LDL-C level after the run-in period on pitavastatin 1 mg/d was 87.7 and 88.1 mg/dL in the high-dose and low-dose groups, respectively. During the entire course of follow-up, LDL-C in the high-dose group was lower by 14.7 mg/dL than in the low-dose group ( P <0.001). With a median follow-up of 3.9 years, high-dose as compared with low-dose pitavastatin significantly reduced the risk of the primary end point (266 patients [4.3%] and 334 patients [5.4%]; hazard ratio, 0.81; 95% confidence interval, 0.69-0.95; P =0.01) and the risk of the secondary composite end point (489 patients [7.9%] and 600 patients [9.7%]; hazard ratio, 0.83; 95% confidence interval, 0.73-0.93; P =0.002). High-dose pitavastatin also significantly reduced the risks of several other secondary end points such as all-cause death, myocardial infarction, and clinically indicated coronary revascularization. The results for the primary and the secondary composite end points were consistent across several prespecified subgroups, including the low (<95 mg/dL) baseline LDL-C subgroup. Serious adverse event rates were low in both groups. High-dose (4 mg/d) compared with low-dose (1 mg/d) pitavastatin therapy significantly reduced cardiovascular events in Japanese patients with stable coronary artery disease. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01042730. © 2018 The Authors.
Dulai, Parambir S; Marquez, Evelyn; Khera, Rohan; Prokop, Larry J; Limburg, Paul J; Gupta, Samir; Murad, Mohammad Hassan
2016-01-01
Objective To assess the comparative efficacy and safety of candidate agents (low and high dose aspirin, non-aspirin non-steroidal anti-inflammatory drugs (NSAIDs), calcium, vitamin D, folic acid, alone or in combination) for prevention of advanced metachronous neoplasia (that is, occurring at different times after resection of initial neoplasia) in individuals with previous colorectal neoplasia, through a systematic review and network meta-analysis. Data sources Medline, Embase, Web of Science, from inception to 15 October 2015; clinical trial registries. Study selection Randomized controlled trials in adults with previous colorectal neoplasia, treated with candidate chemoprevention agents, and compared with placebo or another candidate agent. Primary efficacy outcome was risk of advanced metachronous neoplasia; safety outcome was serious adverse events. Data extraction Two investigators identified studies and abstracted data. A Bayesian network meta-analysis was performed and relative ranking of agents was assessed with surface under the cumulative ranking (SUCRA) probabilities (ranging from 1, indicating that the treatment has a high likelihood to be best, to 0, indicating the treatment has a high likelihood to be worst). Quality of evidence was appraised with GRADE criteria. Results 15 randomized controlled trials (12 234 patients) comparing 10 different strategies were included. Compared with placebo, non-aspirin NSAIDs were ranked best for preventing advanced metachronous neoplasia (odds ratio 0.37, 95% credible interval 0.24 to 0.53; SUCRA=0.98; high quality evidence), followed by low-dose aspirin (0.71, 0.41 to 1.23; SUCRA=0.67; low quality evidence). Low dose aspirin, however, was ranked the safest among chemoprevention agents (0.78, 0.43 to 1.38; SUCRA=0.84), whereas non-aspirin NSAIDs (1.23, 0.95 to 1.64; SUCRA=0.26) were ranked low for safety. High dose aspirin was comparable with low dose aspirin in efficacy (1.12, 0.59 to 2.10; SUCRA=0.58) but had an inferior safety profile (SUCRA=0.51). Efficacy of agents for reducing metachronous colorectal cancer could not be estimated. Conclusions Among individuals with previous colorectal neoplasia, non-aspirin NSAIDs are the most effective agents for the prevention of advanced metachronous neoplasia, whereas low dose aspirin has the most favorable risk:benefit profile. Registration PROSPERO (CRD42015029598). PMID:27919915
Sommer, Wieland H; Albrecht, Edda; Bamberg, Fabian; Schenzle, Jan C; Johnson, Thorsten R; Neumaier, Klement; Reiser, Maximilian F; Nikolaou, Konstatin
2010-12-01
The objective of this study was to compare image quality and radiation dose between high-pitch and established retrospectively and prospectively gated cardiac CT protocols using an Alderson-Rando phantom and a set of patients. An anthropomorphic Alderson-Rando phantom equipped with thermoluminiscent detectors and a set of clinical patients underwent the following cardiac CT protocols: high-pitch acquisition (pitch 3.4), prospectively triggered acquisition, and retrospectively gated acquisition (pitch 0.2). For patients with sinus rhythm below 65 beats per minute (bpm), high-pitch protocol was used, whereas for patients in sinus rhythm between 65 and 100 bpm, prospective triggering was used. Patients with irregular heart rates or heart rates of ≥ 100 bpm, were examined using retrospectively gated acquisition. Evaluability of coronary artery segments was determined, and effective radiation dose was derived from the phantom study. In the phantom study, the effective radiation dose as determined with thermoluminescent detector (TLD) measurements was lowest in the high-pitch acquisition (1.21, 3.12, and 11.81 mSv, for the high-pitch, the prospectively triggered, and the retrospectively gated acquisition, respectively). There was a significant difference with respect to the percentage of motion-free coronary artery segments (99%, 87%, and 92% for high-pitch, prospectively triggered, and retrospectively gated, respectively (p < 0.001), whereas image noise was lowest for the high-pitch protocol (p < 0.05). High-pitch scans have the potential to reduce radiation dose up to 61.2% and 89.8% compared with prospectively triggered and retrospectively gated scans. High-pitch protocols lead to excellent image quality when used in patients with stable heart rates below 65 bpm.
Fully Convolutional Architecture for Low-Dose CT Image Noise Reduction
NASA Astrophysics Data System (ADS)
Badretale, S.; Shaker, F.; Babyn, P.; Alirezaie, J.
2017-10-01
One of the critical topics in medical low-dose Computed Tomography (CT) imaging is how best to maintain image quality. As the quality of images decreases with lowering the X-ray radiation dose, improving image quality is extremely important and challenging. We have proposed a novel approach to denoise low-dose CT images. Our algorithm learns directly from an end-to-end mapping from the low-dose Computed Tomography images for denoising the normal-dose CT images. Our method is based on a deep convolutional neural network with rectified linear units. By learning various low-level to high-level features from a low-dose image the proposed algorithm is capable of creating a high-quality denoised image. We demonstrate the superiority of our technique by comparing the results with two other state-of-the-art methods in terms of the peak signal to noise ratio, root mean square error, and a structural similarity index.
Heo, Jaesung; Noh, O Kyu; Kim, Hwan-Ik; Chun, Mison; Cho, Oyeon; Park, Rae Woong; Yoon, Dukyong; Oh, Young-Taek
2018-04-19
Postoperative radiation therapy may have a detrimental effect on survival in patients with non-small cell lung cancer. We investigated the association of the lung radiation dose with the risk of death in patients treated with postoperative radiation therapy. We analyzed 178 patients with non-small cell lung cancer who received postoperative radiation therapy. The mean lung dose was calculated from dose-volume data, and we categorized patients into the high and low lung dose groups using 2 different methods; (1) simple grouping using the median lung dose of all patients, and (2) stratified grouping using the median lung dose of each subgroup sharing the same confounders. We compared clinical variables, and survival between the high and low lung dose groups. In the simple grouping, there were no significant differences in survivals between the high and low lung dose groups. After stratification, the overall survival of low lung dose group was significantly longer than that of high lung dose group (5-year survival, 60.1% vs. 35.3%, p = 0.039). On multivariable analyses, the lung dose remained a significant prognostic factor for overall survival (hazard ratio, HR = 2.08, p = 0.019). The lung dose was associated with the risk of death in patients with non-small cell lung cancer having the same confounders. Further studies evaluating the risk of death according to the lung dose will be helpful to administer more precise and individualized postoperative radiation therapy. Copyright © 2018 Elsevier B.V. All rights reserved.
Evaluation of the dosimetric properties of a diode detector for small field proton radiosurgery.
McAuley, Grant A; Teran, Anthony V; Slater, Jerry D; Slater, James M; Wroe, Andrew J
2015-11-08
The small fields and sharp gradients typically encountered in proton radiosurgery require high spatial resolution dosimetric measurements, especially below 1-2 cm diameters. Radiochromic film provides high resolution, but requires postprocessing and special handling. Promising alternatives are diode detectors with small sensitive volumes (SV) that are capable of high resolution and real-time dose acquisition. In this study we evaluated the PTW PR60020 proton dosimetry diode using radiation fields and beam energies relevant to radiosurgery applications. Energies of 127 and 157 MeV (9.7 to 15 cm range) and initial diameters of 8, 10, 12, and 20mm were delivered using single-stage scattering and four modulations (0, 15, 30, and 60mm) to a water tank in our treatment room. Depth dose and beam profile data were compared with PTW Markus N23343 ionization chamber, EBT2 Gafchromic film, and Monte Carlo simulations. Transverse dose profiles were measured using the diode in "edge-on" orientation or EBT2 film. Diode response was linear with respect to dose, uniform with dose rate, and showed an orientation-dependent (i.e., beam parallel to, or perpendicular to, detector axis) response of less than 1%. Diodevs. Markus depth-dose profiles, as well as Markus relative dose ratio vs. simulated dose-weighted average lineal energy plots, suggest that any LET-dependent diode response is negligible from particle entrance up to the very distal portion of the SOBP for the energies tested. Finally, while not possible with the ionization chamber due to partial volume effects, accurate diode depth-dose measurements of 8, 10, and 12 mm diameter beams were obtained compared to Monte Carlo simulations. Because of the small SV that allows measurements without partial volume effects and the capability of submillimeter resolution (in edge-on orientation) that is crucial for small fields and high-dose gradients (e.g., penumbra, distal edge), as well as negligible LET dependence over nearly the full the SOBP, the PTW proton diode proved to be a useful high-resolution, real-time metrology device for small proton field radiation measurements such as would be encountered in radiosurgery applications.
Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C
2015-06-01
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
Use of gadoxetic acid for computed tomographic cholangiography in healthy dogs.
Chau, Jennifer; Podadera, Juan M; Young, Alex C; Makara, Mariano A
2017-07-01
OBJECTIVE To evaluate the effect of gadoxetic acid (contrast) dose on biliary tract enhancement, determine the optimal time after contrast injection for CT image acquisition, and assess the feasibility of CT cholangiography in sedated dogs. ANIMALS 8 healthy dogs. PROCEDURES The study had 2 parts. In part 1, 4 dogs were anesthetized and underwent CT cholangiography twice. Gadoxetic acid was administered IV at a low dose (0.025 mmol/kg) for the first procedure and high dose (0.3 mmol/kg) for the second procedure. Serial CT scans were obtained at predetermined times after contrast injection. In part 2, 4 dogs were sedated and underwent CT angiography 85 minutes after IV administration of the high contrast dose. Contrast enhancement of the biliary tract on all scans was objectively assessed by measurement of CT attenuation and qualitatively assessed by use of a subjective 4-point scoring system by 3 independent reviewers. All measurements were compared over time and between contrast doses for the dogs of part 1. Subjective measurements were compared between the sedated dogs of part 2 and anesthetized dogs of part 1. RESULTS Enhancement of the biliary tract was positively associated with contrast dose and time after contrast injection. Optimal enhancement was achieved 65 minutes after contrast injection. Subjective visualization of most biliary structures did not differ significantly between sedated and anesthetized dogs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated CT cholangiography with gadoxetic acid was feasible in sedated dogs. The high contrast dose provided better visualization of biliary structures than the low dose; CT scans should be obtained 65 minutes after contrast injection.
Luhovyy, Bohdan L; Mollard, Rebecca C; Yurchenko, Svitlana; Nunez, Maria Fernanda; Berengut, Shari; Liu, Ting Ting; Smith, Christopher E; Pelkman, Christine L; Anderson, G Harvey
2014-12-01
The objective of this study was to determine the dose response effect of whole grain high-amylose maize (HAM) flour as a source of resistant starch (RS) on blood glucose, appetite and short-term food intake. In a repeated-measures crossover trial, healthy men (n = 30, 22.9 ± 0.6 y, BMI of 22.6 ± 0.3 kg/m(2)) were randomly assigned to consume 1 of 3 cookies once a week for 3 wk. Cookies were control (100% wheat flour), low-dose (63% wheat flour,37% HAM flour), and high-dose (33% wheat flour, 67% HAM flour) providing 53.5, 43.5, and 36.3 g of available carbohydrate, respectively. Ad libitum food intake was measured 120 min at a pizza meal, blood glucose and subjective appetite were measured after consumption of the cookie (0 to 120 min) and after the pizza meal (140 to 200 min). Blood glucose concentrations were lower at 30 and 45 min after high-dose treatment, and at 120 min after both high- and low-dose treatments compared to control (P < 0.05). Blood glucose AUC before the pizza meal (0 to 120 min) was 44% and 14% lower, and higher by 43% and 41% after the pizza meal (140 to 200 min) compared with control. Yet despite the higher response following the meal, cumulative AUC (0 to 200 min) was still 22% lower after the high-dose treatment (P < 0.05). All treatments equally suppressed subjective appetite and there was no effect on food intake. In conclusion, HAM flour as a source of RS and incorporated into a cookie was associated with better glycemic control in young men. © 2014 Institute of Food Technologists®
MAGIC with formaldehyde applied to dosimetry of HDR brachytherapy source
NASA Astrophysics Data System (ADS)
Marques; T; Fernandes; J; Barbi; G; Nicolucci; P; Baffa; O
2009-05-01
The use of polymer gel dosimeters in brachytherapy can allow the determination of three-dimensional dose distributions in large volumes and with high spatial resolution if an adequate calibration process is performed. One of the major issues in these experiments is the polymer gel response dependence on dose rate when high dose rate sources are used and the doses in the vicinity of the sources are to be determinated. In this study, the response of a modified MAGIC polymer gel with formaldehyde around an Iridium-192 HDR brachytherapy source is presented. Experimental results obtained with this polymer gel were compared with ionization chamber measurements and with Monte Carlo simulation with PENELOPE. A maximum difference of 3.10% was found between gel dose measurements and Monte Carlo simulation at a radial distance of 18 mm from the source. The results obtained show that the gel's response is strongly influenced by dose rate and that a different calibration should be used for the vicinity of the source and for regions of lower dose rates. The results obtained in this study show that, provided the proper calibration is performed, MAGIC with formaldehyde can be successfully used to accurate determinate dose distributions form high dose rate brachytherapy sources.
Acceleration of atherogenesis in ApoE-/- mice exposed to acute or low-dose-rate ionizing radiation.
Mancuso, Mariateresa; Pasquali, Emanuela; Braga-Tanaka, Ignacia; Tanaka, Satoshi; Pannicelli, Alessandro; Giardullo, Paola; Pazzaglia, Simonetta; Tapio, Soile; Atkinson, Michael J; Saran, Anna
2015-10-13
There is epidemiological evidence for increased non-cancer mortality, primarily due to circulatory diseases after radiation exposure above 0.5 Sv. We evaluated the effects of chronic low-dose rate versus acute exposures in a murine model of spontaneous atherogenesis. Female ApoE-/- mice (60 days) were chronically irradiated for 300 days with gamma rays at two different dose rates (1 mGy/day; 20 mGy/day), with total accumulated doses of 0.3 or 6 Gy. For comparison, age-matched ApoE-/- females were acutely exposed to the same doses and sacrificed 300 days post-irradiation. Mice acutely exposed to 0.3 or 6 Gy showed increased atherogenesis compared to age-matched controls, and this effect was persistent. When the same doses were delivered at low dose rate over 300 days, we again observed a significant impact on global development of atherosclerosis, although at 0.3 Gy effects were limited to the descending thoracic aorta. Our data suggest that a moderate dose of 0.3 Gy can have persistent detrimental effects on the cardiovascular system, and that a high dose of 6 Gy poses high risks at both high and low dose rates. Our results were clearly nonlinear with dose, suggesting that lower doses may be more damaging than predicted by a linear dose response.
LET spectra measurements from the STS-35 CPDs
NASA Technical Reports Server (NTRS)
1995-01-01
Linear energy transfer (LET) spectra derived form automated track analysis system (ATAS) track parameter measurements for crew passive dosimeters (CPD's) flown with the astronauts on STS-35 are plotted. The spread between the seven individual spectra is typical of past manual measurements of sets of CPD's. This difference is probably due to the cumulative net shielding variations experienced by the CPD's as the astronauts carrying them went about their activities on the Space Shuttle. The STS-35 mission was launched on Dec. 2, 1990, at 28.5 degrees inclination and 352-km altitude. This is somewhat higher than the nominal 300-km flights and the orbit intersects more of the high intensity trapped proton region in the South Atlantic Anomaly (SAA). However, in comparison with APD spectra measured on earlier lower altitude missions (STS-26, -29, -30, -32), the flux spectra are all roughly comparable. This may be due to the fact that the STS-35 mission took place close to solar maximum (Feb. 1990), or perhaps to shielding differences. The corresponding dose and dose equivalent spectra for this mission are shown. The effect of statistical fluctuations at the higher LET values, where track densities are small, is very noticeable. This results in an increased spread within the dose rate and dose equivalent rate spectra, as compared to the flux spectra. The contribution to dose and dose equivalent per measured track is much greater in the high LET region and the differences, though numerically small, are heavily weighted in the integral spectra. The optimum measurement and characterization of the high LET tails of the spectra represent an important part of the research into plastic nuclear track detector (PNTD) response. The integral flux, dose rate, dose equivalent rate and mission dose equivalent for the seven astronauts are also given.
Mori, Takehiko; Koh, Hideo; Onishi, Yasushi; Kako, Shinichi; Onizuka, Makoto; Kanamori, Heiwa; Ozawa, Yukiyasu; Kato, Chiaki; Iida, Hiroatsu; Suzuki, Ritsuro; Ichinohe, Tatsuo; Kanda, Yoshinobu; Maeda, Tetsuo; Nakao, Shinji; Yamazaki, Hirohito
2016-04-01
The standard conditioning regimen in allogeneic hematopoietic stem cell transplantation (HSCT) for aplastic anemia from a human leukocyte antigen (HLA)-identical sibling has been high-dose cyclophosphamide (CY 200 mg/kg). In the present study, results for 203 patients with aplastic anemia aged 16 years or older who underwent allogeneic HSCT from HLA-identical siblings were retrospectively analyzed using the registry database of Japan Society for Hematopoietic Cell Transplantation. Conditioning regimens were defined as a (1) high-dose CY (200 mg/kg or greater)-based (n = 117); (2) reduced-dose CY (100 mg/kg or greater, but less than 200 mg/kg)-based (n = 38); and (3) low-dose CY (less than 100 mg/kg)-based (n = 48) regimen. Patient age and the proportion of patients receiving fludarabine were significantly higher in the reduced- and low-dose CY groups than the high-dose CY group. Engraftment was comparable among the groups. Five-year overall survival (OS) tended to be higher in the low-dose CY group [93.0 % (95 % CI 85.1-100.0 %)] than the high-dose CY [84.2 % (95 % CI 77.1-91.3 %)] or reduced-dose CY groups [83.8 % (95 % CI 71.8-95.8 %); P = 0.214]. Age-adjusted OS was higher in the low-dose CY group than the high- and reduced-dose CY groups with borderline significance (P = 0.067). These results suggest that CY dose can safely be reduced without increasing graft rejection by adding fludarabine in allogeneic HSCT for aplastic anemia from an HLA-identical sibling.
Shiga, Yuhei; Miura, Shin-Ichiro; Norimatsu, Kenji; Hitaka, Yuka; Nagata, Itsuki; Koyoshi, Rie; Morii, Joji; Kuwano, Takashi; Uehara, Yoshinari; Inoue, Asao; Shirotani, Tetsuro; Fujisawa, Kazuaki; Matsunaga, Eiyu; Saku, Keijiro
2015-12-01
We analyzed the efficacy and safety of combination therapy of high-dose losartan (100 mg/day) and hydrochlorothiazide (HCTZ, 12.5 mg/day) compared with those of the combination of high-dose telmisartan (80 mg/day) and HCTZ (12.5 mg/day). Forty hypertensive patients who received a combination of high-dose telmisartan and HCTZ were enrolled. We applied a changeover strategy with switching from a combination of high-dose telmisartan and HCTZ to high-dose losartan and HCTZ. We divided the patients into two groups; those who achieved the target blood pressure (controlled group) and those who did not reach the target blood pressure (uncontrolled group) before the changeover and performed further analysis. The uncontrolled group showed a significant decrease in systolic blood pressure (SBP) (143±12 mmHg to 126±11 mmHg at three months). In addition, serum uric acid significantly decreased in all subjects, and in each of the controlled and uncontrolled groups. There were no significant changes in other biochemical parameters, such as potassium and hemoglobin A1c, at three months after the changeover in all subjects. Combination therapy with high-dose losartan and HCTZ was superior to the combination of telmisartan and HCTZ with respect to significant decreases in systolic blood pressure and serum uric acid in hypertensive patients. © The Author(s) 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopp, Robert W.; Duff, Michael, E-mail: mduff@cancercarewny.com; Catalfamo, Frank
2011-01-01
We compared normal tissue radiation dose for the treatment of prostate cancer using 2 different radiation therapy delivery methods: volumetric modulated arc therapy (VMAT) vs. fixed-field intensity-modulated radiation therapy (IMRT). Radiotherapy plans for 292 prostate cancer patients treated with VMAT to a total dose of 7740 cGy were analyzed retrospectively. Fixed-angle, 7-field IMRT plans were created using the same computed tomography datasets and contours. Radiation doses to the planning target volume (PTV) and organs at risk (bladder, rectum, penile bulb, and femoral heads) were measured, means were calculated for both treatment methods, and dose-volume comparisons were made with 2-tailed, pairedmore » t-tests. The mean dose to the bladder was lower with VMAT at all measured volumes: 5, 10, 15, 25, 35, and 50% (p < 0.05). The mean doses to 5 and 10% of the rectum, the high-dose regions, were lower with VMAT (p < 0.05). The mean dose to 15% of the rectal volume was not significantly different (p = 0.95). VMAT exposed larger rectal volumes (25, 35, and 50%) to more radiation than fixed-field IMRT (p < 0.05). Average mean dose to the penile bulb (p < 0.05) and mean dose to 10% of the femoral heads (p < 0.05) were lower with VMAT. VMAT therapy for prostate cancer has dosimetric advantages for critical structures, notably for high-dose regions compared with fixed-field IMRT, without compromising PTV coverage. This may translate into reduced acute and chronic toxicity.« less
Multiple anatomy optimization of accumulated dose
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V.; Moore, Joseph A.
Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dosemore » variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.« less
Guerrero, Rafael; Almansa, Julio F; Torres, Javier; Lallena, Antonio M
2014-12-01
(60)Co sources are being used as an alternative to (192)Ir sources in high dose rate brachytherapy treatments. In a recent document from AAPM and ESTRO, a consensus dataset for the (60)Co BEBIG (model Co0.A86) high dose rate source was prepared by using results taken from different publications due to discrepancies observed among them. The aim of the present work is to provide a new calculation of the dosimetric characteristics of that (60)Co source according to the recommendations of the AAPM and ESTRO report. Radial dose function, anisotropy function, air-kerma strength, dose rate constant and absorbed dose rate in water have been calculated and compared to the results of previous works. Simulations using the two different geometries considered by other authors have been carried out and the effect of the cable density and length has been studied. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Web based scoring is useful for validation and harmonisation of scoring criteria within RENEB.
Romm, Horst; Ainsbury, Elizabeth A; Barquinero, Joan Francesc; Barrios, Leonardo; Beinke, Christina; Cucu, Alexandra; Domene, Mercedes Moreno; Filippi, Silvia; Monteiro Gil, Octávia; Gregoire, Eric; Hadjidekova, Valeria; Hatzi, Vasia; Lindholm, Carita; M Kacher, Radhia; Montoro, Alegria; Moquet, Jayne; Noditi, Mihaela; Oestreicher, Ursula; Palitti, Fabrizio; Pantelias, Gabriel; Prieto, María Jesús; Popescu, Irina; Rothkamm, Kai; Sebastià, Natividad; Sommer, Sylwester; Terzoudi, Georgia; Testa, Antonella; Wojcik, Andrzej
2017-01-01
To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.
Dharmarajan, Satheesh Kumar; Arumugam, Kottai Muthu
2012-10-02
The objective of the study is a comparative evaluation of flavone isolated from Mucuna pruriens and coumarin isolated from Ionidium suffruticosum was assessed for the hypolipidemic activity in rats fed with high fat diet. The acute toxicity study was found that flavone (M.pruriens) and coumarin (I.suffruticosum) are safe up to 100 mg/kg, so one tenth of this dose (10 mg/kg) was consider as a evaluation dose. High fat diet group of rats showed significant (p<0.001) elevation in plasma total and LDL-cholesterol, triglycerides and phospholipids. Administration of flavone (M. pruriens) and coumarin isolated from (I.suffruticosum) at the dose of 10mg/kg b.wt/day along with high fat diet significantly (p<0.001) prevented the rise in the plasma total and LDL-cholesterol, triglycerides and phospholipids than that of other extracts. However, treatment of coumarin isolated from (I.suffruticosum) had showed more cardio protective effect against hyperlipidemia than that of flavone (M.pruriens).
Miao, F J; Benowitz, N L; Heller, P H; Levine, J D
1997-01-01
1. In this study, we examined the mechanism(s) by which s.c. nicotine inhibits synovial plasma extravasation. We found that nicotine dose-dependently inhibited bradykinin (BK)- and platelet activating factor (PAF)-induced plasma extravasation. 2. The effect of nicotine on both BK- and PAF-induced plasma extravasation was attenuated by adrenal medullectomy. ICI-118,551 (a selective beta 2-adrenoceptor blocker) (30 micrograms ml-1, intra-articularly) significantly attenuated the inhibitory action of high-dose (1 mg kg-1) nicotine on BK-induced plasma extravasation without affecting the inhibition by low- (0.01 microgram kg-1) dose nicotine or that on PAF-induced plasma extravasation by nicotine at any dose. This suggested that beta 2-adrenoceptors mediate the inhibitory actions of high-dose, but not low-dose, nicotine. We also found that systemic naloxone (an opioid receptor antagonist) (two hourly injections of 1 mg kg-1, i.p.) attenuated the inhibitory action produced by all doses of nicotine on BK- or PAF-induced plasma extravasation, suggesting the contribution of endogenous opioids. 3. RU-38,486 (a glucocorticoid receptor antagonist) (30 mg kg-1, s.c.), and metyrapone (a glucocorticoid synthesis inhibitor) (two hourly injections of 100 mg kg-1, i.p.) both attenuated the action of high-dose nicotine without affecting that of low-dose nicotine. 4. Spinal mecamylamine (a nicotinic receptor antagonist) (0.025 mg kg-1, intrathecally, i.t.) attenuated the action of high-dose, but not low-dose, nicotine, suggesting that part of the action of high-dose nicotine is mediated by spinal nicotinic receptors. 5. Combined treatment with ICI-118,551, naloxone and RU-38,486 attenuated the action of low-dose nicotine by an amount similar to that produced by naloxone alone but produced significantly greater attenuation of the effect of high-dose nicotine when compared to the action of any of the three antagonists alone.
Jia-Pei Miao, Frederick; Benowitz, Neal L; Heller, Philip H; Levine, Jon D
1997-01-01
In this study, we examined the mechanism(s) by which s.c. nicotine inhibits synovial plasma extravasation. We found that nicotine dose-dependently inhibited bradykinin (BK)- and platelet activating factor (PAF)-induced plasma extravasation. The effect of nicotine on both BK- and PAF-induced plasma extravasation was attenuated by adrenal medullectomy. ICI-118,551 (a selective β2-adrenoceptor blocker) (30 μg ml−1, intra-articularly) significantly attenuated the inhibitory action of high-dose (1 mg kg−1) nicotine on BK-induced plasma extravasation without affecting the inhibition by low- (0.01 μg kg−1) dose nicotine or that on PAF-induced plasma extravasation by nicotine at any dose. This suggested that β2-adrenoceptors mediate the inhibitory actions of high-dose, but not low-dose, nicotine. We also found that systemic naloxone (an opioid receptor antagonist) (two hourly injections of 1 mg kg−1, i.p.) attenuated the inhibitory action produced by all doses of nicotine on BK- or PAF-induced plasma extravasation, suggesting the contribution of endogenous opioids. RU-38,486 (a glucocorticoid receptor antagonist) (30 mg kg−1, s.c.) and metyrapone (a glucocorticoid synthesis inhibitor) (two hourly injections of 100 mg kg−1, i.p.) both attenuated the action of high-dose nicotine without affecting that of low-dose nicotine. Spinal mecamylamine (a nicotinic receptor antagonist) (0.025 mg kg−1, intrathecally, i.t.) attenuated the action of high-dose, but not low-dose, nicotine, suggesting that part of the action of high-dose nicotine is mediated by spinal nicotinic receptors. Combined treatment with ICI-118,551, naloxone and RU-38,486 attenuated the action of low-dose nicotine by an amount similar to that produced by naloxone alone but produced significantly greater attenuation of the effect of high-dose nicotine when compared to the action of any of the three antagonists alone. PMID:9117123
Dose-Response Analysis of RNA-Seq Profiles in Archival ...
Use of archival resources has been limited to date by inconsistent methods for genomic profiling of degraded RNA from formalin-fixed paraffin-embedded (FFPE) samples. RNA-sequencing offers a promising way to address this problem. Here we evaluated transcriptomic dose responses using RNA-sequencing in paired FFPE and frozen (FROZ) samples from two archival studies in mice, one 20 years old. Experimental treatments included 3 different doses of di(2-ethylhexyl)phthalate or dichloroacetic acid for the recently archived and older studies, respectively. Total RNA was ribo-depleted and sequenced using the Illumina HiSeq platform. In the recently archived study, FFPE samples had 35% lower total counts compared to FROZ samples but high concordance in fold-change values of differentially expressed genes (DEGs) (r2 = 0.99), highly enriched pathways (90% overlap with FROZ), and benchmark dose estimates for preselected target genes (2% difference vs FROZ). In contrast, older FFPE samples had markedly lower total counts (3% of FROZ) and poor concordance in global DEGs and pathways. However, counts from FFPE and FROZ samples still positively correlated (r2 = 0.84 across all transcripts) and showed comparable dose responses for more highly expressed target genes. These findings highlight potential applications and issues in using RNA-sequencing data from FFPE samples. Recently archived FFPE samples were highly similar to FROZ samples in sequencing q
Takada, Kenta; Kumada, Hiroaki; Liem, Peng Hong; Sakurai, Hideyuki; Sakae, Takeji
2016-12-01
We simulated the effect of patient displacement on organ doses in boron neutron capture therapy (BNCT). In addition, we developed a faster calculation algorithm (NCT high-speed) to simulate irradiation more efficiently. We simulated dose evaluation for the standard irradiation position (reference position) using a head phantom. Cases were assumed where the patient body is shifted in lateral directions compared to the reference position, as well as in the direction away from the irradiation aperture. For three groups of neutron (thermal, epithermal, and fast), flux distribution using NCT high-speed with a voxelized homogeneous phantom was calculated. The three groups of neutron fluxes were calculated for the same conditions with Monte Carlo code. These calculated results were compared. In the evaluations of body movements, there were no significant differences even with shifting up to 9mm in the lateral directions. However, the dose decreased by about 10% with shifts of 9mm in a direction away from the irradiation aperture. When comparing both calculations in the phantom surface up to 3cm, the maximum differences between the fluxes calculated by NCT high-speed with those calculated by Monte Carlo code for thermal neutrons and epithermal neutrons were 10% and 18%, respectively. The time required for NCT high-speed code was about 1/10th compared to Monte Carlo calculation. In the evaluation, the longitudinal displacement has a considerable effect on the organ doses. We also achieved faster calculation of depth distribution of thermal neutron flux using NCT high-speed calculation code. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Comparison in vivo Study of Genotoxic Action of High- Versus Very Low Dose-Rate γ-Irradiation
Osipov, A. N.; Klokov, D. Y.; Elakov, A. L.; Rozanova, O. M.; Zaichkina, S. I.; Aptikaeva, G. F.; Akhmadieva, A. Kh.
2004-01-01
The aim of the present study was to compare genotoxicity induced by high- versus very low dose-rate exposure of mice to γ-radiation within a dose range of 5 to 61 cGy using the single-cell gel electrophoresis (comet) assay and the micronucleus test. CBA/lac male mice were irradiated at a dose rate of 28.2 Gy/h (high dose rate) or 0.07 mGy/h (very low dose rate). The comet assay study on spleen lymphocytes showed that very low dose-rate irradiation resulted in a statistically significant increase in nucleoid relaxation (DNA breaks), starting from a dose of 20 cGy. Further prolongation of exposure time and, hence, increase of a total dose did not, however, lead to further increase in the extent of nucleoid relaxation. Doses of 20 and 61 cGy were equal in inducing DNA breaks in mouse spleen lymphocytes as assayed by the comet assay. Of note, the level of DNA damage by 20–61 cGy doses of chronic irradiation (0.07 mGy/h) was similar to that an induced by an acute (28.2 Gy/h) dose of 14 cGy. The bone marrow micronucleus test revealed that an increase in polychromatic erythrocytes with micronuclei over a background level was induced by very low-level γ-irradiation with a dose of 61 cGy only, with the extent of the cytogenetic effect being similar to that of 10 cGy high-dose-rate exposure. In summary, presented results support the hypothesis of the nonlinear threshold nature of mutagenic action of chronic low dose-rate irradiation. PMID:19330145
Choi, Ji-Young; Shin, Su-Kyung; Jeon, Seon-Min; Baek, Nam-In; Chung, Hae-Gon; Jeong, Tae-Sook; Lee, Kyung Tae; Lee, Mi-Kyung; Choi, Myung-Sook
2011-01-01
Previously we reported that an ethanol extract from Artemisia princeps Pampanini lowered blood glucose in db/db mice. Here we report a preliminary study in which the blood glucose-lowering effects of two different doses of sajabalssuk ethanol extract (SBE), containing eupatilin and jaseocidin, were examined in hyperglycemic subjects with fasting blood glucose (FBG) levels of 100-150 mg/dL. Subjects were randomized into four groups: negative control (2,000 mg of lactose /day), positive control (1,140 mg of pinitol/day), low-dose SBE (2,000 mg of SBE/day), and high-dose SBE (4,000 mg of SBE/day). After 8 weeks of supplementation, FBG and glycosylated hemoglobin levels were significantly lowered in low-and high-dose SBE groups compared to the baseline values; high-dose SBE also resulted in significantly lower plasma free fatty acid levels and systolic blood pressure. This study demonstrated that supplementation of 2 g or 4 g of SBE daily can significantly reduce blood glucose in hyperglycemic subjects, although high-dose SBE seemed to be more effective than low-dose SBE for lowering plasma free fatty acid level and systolic blood pressure.
SU-F-T-441: Dose Calculation Accuracy in CT Images Reconstructed with Artifact Reduction Algorithm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, C; Chan, S; Lee, F
Purpose: Accuracy of radiotherapy dose calculation in patients with surgical implants is complicated by two factors. First is the accuracy of CT number, second is the dose calculation accuracy. We compared measured dose with dose calculated on CT images reconstructed with FBP and an artifact reduction algorithm (OMAR, Philips) for a phantom with high density inserts. Dose calculation were done with Varian AAA and AcurosXB. Methods: A phantom was constructed with solid water in which 2 titanium or stainless steel rods could be inserted. The phantom was scanned with the Philips Brillance Big Bore CT. Image reconstruction was done withmore » FBP and OMAR. Two 6 MV single field photon plans were constructed for each phantom. Radiochromic films were placed at different locations to measure the dose deposited. One plan has normal incidence on the titanium/steel rods. In the second plan, the beam is at almost glancing incidence on the metal rods. Measurements were then compared with dose calculated with AAA and AcurosXB. Results: The use of OMAR images slightly improved the dose calculation accuracy. The agreement between measured and calculated dose was best with AXB and image reconstructed with OMAR. Dose calculated on titanium phantom has better agreement with measurement. Large discrepancies were seen at points directly above and below the high density inserts. Both AAA and AXB underestimated the dose directly above the metal surface, while overestimated the dose below the metal surface. Doses measured downstream of metal were all within 3% of calculated values. Conclusion: When doing treatment planning for patients with metal implants, care must be taken to acquire correct CT images to improve dose calculation accuracy. Moreover, great discrepancies in measured and calculated dose were observed at metal/tissue interface. Care must be taken in estimating the dose in critical structures that come into contact with metals.« less
Bioavailability of a Sustained Release Formulation of Curcumin
Madhavi, Doddabele; Kagan, Daniel
2014-01-01
Context Curcumin has a number of beneficial effects, such as functioning as a potent antioxidant,1 anti-inflammatory, 2 and anticancer agent. Because of its poor oral bioavailability, very high oral doses and repeated dosing have been used to obtain effective plasma levels, with mixed results. High doses of curcumin may cause gastric disturbance, often resulting in poor patient compliance. Objective The objective of this study was to compare the relative bioavailability of MicroActive Curcumin—an advanced, micronized formulation of curcumin that is 25% curcuminoids in a sustained release matrix—with that of an unformulated, 95% pure curcumin powder. Design A dissolution study compared the solubility of the formulated and the unformulated curcumin. The research team also performed a single-dose, 12-h, crossover uptake study with 10 participants and a high-dose tolerability and accumulation study with 3 participants, comparing the 2 forms of curcumin. Setting The study was done in MAZE Laboratories (Purchase, NY, USA). Participants Ten healthy male and female volunteers, aged 21–66 y, took part in the single-dose study. Three participants, 2 female and 1 male aged 40–55 y, took part in the tolerability and accumulation study. The participants were people from the community. Intervention For the dissolution study, the research team filled hard gelatin capsules with unformulated 95% curcumin powder and the MicroActive Curcumin powder to the equivalent of 25 mg curcuminoids. For the single-dose study, participants received 500 mg of curcumin in 2 forms. MicroActive Curcumin capsules were administered after breakfast, and blood samples were drawn at 1, 2, 4, 8, and 12 h postdose. After a 7-d washout period, the protocol was repeated for unformulated, 95% curcumin powder capsules. For the tolerability study, the unformulated, 95% curcumin powder was given at a dose that provided 2 g of curcumin for 7 d followed by 5 g of curcumin for an additional 7 d. After a washout period of 14 d, the protocol was repeated with MicroActive Curcumin. Participants then continued to take the MicroActive Curcumin for >3 mo. Outcome Measures For the dissolution study, the curcumin was quantified at room temperature using reverse-phase, high-performance liquid chromatography (HPLC) with a Phenomenex Luna column (150 × 4.6 mm, 5 μm) (Phenomenex Inc, Torrance, CA, USA). For the single-dose and the tolerability studies, hydrolysis of conjugates and extraction of curcuminoids from the plasma were performed. The curcuminoids were quantified using reverse-phase HPLC with an ultraviolet-visible detector as described above. Results The dissolution study indicated that the sustained-release curcumin had greater dissolution for 12 h at all points tested, compared with the unformulated curcumin. Very little of the unformulated curcumin powder had been released at the end of the 12 h. The results of the single-dose uptake study indicated that the sustained-release formula was 9.7 × more bioavailable than the unformulated powder (P < .001, paired t test). Additionally, all participants showed uptake from the sustained-release formulation. That formulation also resulted in significant increases in the plasma demethoxylated curcuminoids, but the research team did not observe the same increases for the unformulated curcumin powder. The sustained-release formulation was well tolerated, without adverse effects in the high-dose tolerability study. Conclusions Formulation of micronized curcumin in a combination of surfactants, oils, and polymers improves the absorption of curcumin. In addition, the unique plasma demethylated curcuminoid profile may enhance the therapeutic effects of MicroActive Curcumin not observed with unformulated curcumin at moderate and well-tolerated doses. MicroActive Curcumin was well tolerated, without any adverse effects in a high-dose tolerability study. These properties have the potential to make high-dose curcumin supplementation more accessible through simplified incorporation into food and beverage preparations. PMID:26770097
Blazer, V.S.; Densmore, Christine L.; Schill, W.B.; Cartwright, Deborah D.; Page, S.J.
2004-01-01
The susceptibility of lake trout Salvelinus namaycush, rainbow trout Oncorhynchus mykiss and Atlantic salmon Salmo salar to Myxobolus cerebralis, the causative agent of whirling disease, was compared in controlled laboratory exposures. A total of 450 (225 for each dose) fry for each species were exposed to a low (200 spores per fish) or high (2000 spores per fish) dose of the infective triactinomyxon. At 22 wk post-exposure, 60 fish from each group, as well as controls for each species, were examined for clinical signs (whirling behavior, blacktail, deformed heads and skeletal deformities), microscopic lesions, and presence of spores. Rainbow trout were highly susceptible to infection, with 100% being positive for spores and with microscopic pathological changes in both exposure groups. Rainbow trout were the only species to show whirling behavior and blacktail. Atlantic salmon were less susceptible, with only 44 and 61% being positive for spores, respectively, in the low and high dose groups, while 68 and 75%, respectively, had microscopic pathology associated with cartilage damage. Rainbow trout heads contained mean spore concentrations of 2.2 (low dose) or 4.0 (high dose) ?? 106 spores g tissue-1. The means for positive Atlantic salmon (not including zero values) were 1.7 (low) and 7.4 (high) ?? 104 spores g tissue-1. Lake trout showed no clinical signs of infection, were negative for spores in both groups and showed no histopathological signs of M. cerebralis infection.
Blazer, V S; Densmore, C L; Schill, W B; Cartwright, D D; Page, S J
2004-01-28
The susceptibility of lake trout Salvelinus namaycush, rainbow trout Oncorhynchus mykiss and Atlantic salmon Salmo salar to Myxobolus cerebralis, the causative agent of whirling disease, was compared in controlled laboratory exposures. A total of 450 (225 for each dose) fry for each species were exposed to a low (200 spores per fish) or high (2000 spores per fish) dose of the infective triactinomyxon. At 22 wk post-exposure, 60 fish from each group, as well as controls for each species, were examined for clinical signs (whirling behavior, blacktail, deformed heads and skeletal deformities), microscopic lesions, and presence of spores. Rainbow trout were highly susceptible to infection, with 100% being positive for spores and with microscopic pathological changes in both exposure groups. Rainbow trout were the only species to show whirling behavior and blacktail. Atlantic salmon were less susceptible, with only 44 and 61% being positive for spores, respectively, in the low and high dose groups, while 68 and 75%, respectively, had microscopic pathology associated with cartilage damage. Rainbow trout heads contained mean spore concentrations of 2.2 (low dose) or 4.0 (high dose) x 10(6) spores g tissue(-1). The means for positive Atlantic salmon (not including zero values) were 1.7 (low) and 7.4 (high) x 10(4) spores g tissue(-1). Lake trout showed no clinical signs of infection, were negative for spores in both groups and showed no histopathological signs of M. cerebralis infection.
Sun, Hao; Xue, Hua-dan; Jin, Zheng-yu; Wang, Xuan; Chen, Yu; He, Yong-lan; Zhang, Da-ming; Zhu, Liang; Wang, Yun; Qi, Bing; Xu, Kai; Wang, Ming
2014-10-01
To retrospectively evaluate the clinical feasibility of high-pitch excretory phase images during dual-source CT urography with Stellar photon detector. Totally 100 patients received dual-source CT high-pitch urinary excretory phase scanning with Stellar photon detector [80 kV, ref.92 mAs, CARE Dose 4D and CARE kV, pitch of 3.0, filter back projection reconstruction algorithm (FBP)] (group A). Another 100 patients received dual-source CT high-pitch urinary excretory phase scanning with common detector(100 kV, ref.140 mAs, CARE Dose 4D, pitch of 3.0, FBP) (group B). Quantitative measurement of CT value of urinary segments (Hounsfield units), image noise (Hounsfield units), and effective radiation dose (millisievert) were compared using independent-samples t test between two groups. Urinary system subjective opacification scores were compared using Mann-Whitney U test between two groups. There was no significant difference in subjective opacification score of intrarenal collecting system and ureters between two groups (all P>0.05). The group A images yielded significantly higher CT values of all urinary segments (all P<0.01). There was no significant difference in image noise (P>0.05). The effective radiation dose of group A (1.1 mSv) was significantly lower than that of group B (3.79 mSv) (P<0.01). High-pitch low-tube-voltage during excretory phase dual-source CT urography with Stellar photon detector is feasible, with acceptable image noise and lower radiation dose.
Horikawa, Reiko; Tanaka, Toshiaki; Nishinaga, Hiromi; Ogawa, Yoshihisa; Yokoya, Susumu
2017-01-01
Abstract. Some children born small for gestational age (SGA) have short stature and are at an increased risk of developing psychosocial or behavioral problems. Here we evaluated the efficacy of GH and its effects on the timing of pubertal onset in a 3-yr extension of our previous 2-yr (total 5 yr) multicenter, randomized, double-blind, parallel-group clinical trial of 65 short Japanese children born SGA. Patients received low or high doses of GH (0.033 or 0.067 mg/kg/day, respectively). Age at onset of puberty was not statistically different for male and female patients receiving high- or low-dose GH. After the onset of puberty, no difference in height gain was observed between the two GH dose groups. At the onset of puberty, height standard deviation scores for chronological age of boys and girls improved significantly in both dose groups with evidence of a dose-response effect. Mean bone age/chronological age ratios in the low- and high-dose groups were significantly increased compared with baseline, being significantly greater in the high-dose group at 5 yr after treatment initiation. Delayed bone age at baseline was close to chronological age following GH treatment. GH treatment, especially high-dose GH, induced advanced bone age in short children born SGA. PMID:28458458
Kiernan, Michael S; Stevens, Susanna R; Tang, W H Wilson; Butler, Javed; Anstrom, Kevin J; Birati, Edo Y; Grodin, Justin L; Gupta, Divya; Margulies, Kenneth B; LaRue, Shane; Dávila-Román, Victor G; Hernandez, Adrian F; de Las Fuentes, Lisa
2018-03-01
Poor response to loop diuretic therapy is a marker of risk during heart failure hospitalization. We sought to describe baseline determinants of diuretic response and to further explore the relationship between this response and clinical outcomes. Patient data from the National Heart, Lung, and Blood Institute Heart Failure Network ROSE-AHF and CARRESS-HF clinical trials were analyzed to determine baseline determinants of diuretic response. Diuretic efficiency (DE) was defined as total 72-hour fluid output per total equivalent loop diuretic dose. Data from DOSE-AHF was then used to determine if these predictors of DE correlated with response to a high- versus low-dose diuretic strategy. At 72 hours, the high-DE group had median fluid output of 9071 ml (interquartile range: 7240-11775) with median furosemide dose of 320 mg (220-480) compared with 8030 ml (6300-9915) and 840 mg (600-1215) respectively for the low DE group. Cystatin C was independently associated with DE (odds ratio 0.36 per 1mg/L increase; 95% confidence interval: 0.24-0.56; P < 0.001). Independently from baseline characteristics, reduced fluid output, weight loss and DE were each associated with increased 60 day mortality. Among patients with estimated glomerular filtration rate below the median, those randomized to a high-dose strategy had improved symptoms compared with those randomized to a low-dose strategy. Elevated baseline cystatin C, as a biomarker of renal dysfunction, is associated with reduced diuretic response during heart failure hospitalization. Higher loop diuretic doses are required for therapeutic decongestion in patients with renal insufficiency. Poor response identifies a high-risk population. Copyright © 2018 Elsevier Inc. All rights reserved.
Effects of Chronic Genistein Treatment in Mammary Gland, Uterus, and Vagina
Rimoldi, Guillermo; Christoffel, Julie; Seidlova-Wuttke, Dana; Jarry, Hubertus; Wuttke, Wolfgang
2007-01-01
Background The isoflavone genistein (GEN) is found in soy (Glycine max) and red clover (Trifolium pratense). The estrogenic activity of GEN is known, and it is widely advertised as a phytoestrogen useful in alleviating climacteric complaints and other postmenopausal disorders. Knowledge of effects of long-term administration of GEN in laboratory animals is scarce, and effects in the uterus and mammary gland after long-term administration have not been studied. The uterus and mammary gland are known to be negatively influenced by estrogens used in hormone therapy. Objectives We administered two doses of GEN [mean daily uptake 5.4 (low) or 54 mg/kg (high) body weight (bw)] orally over a period of 3 months to ovariectomized (ovx) rats and compared the effects with a treatment with two doses of 17β-estradiol [E2; 0.17 (low) or 0.7 mg/kg bw (high)]. Mammary glands, vaginae, and uteri were investigated morphologically and immunohistochemically. We quantified the expression of proliferating cell nuclear antigen (PCNA) and progesterone receptor (PR) in the mammary gland. Results In rats treated with either of the E2 doses or the high GEN dose, we found increased uterine weight, and histologic analysis showed estrogen-induced features in the uteri. In vaginae, either E2 dose or GEN high induced hyperplastic epithelium compared with the atrophic controls. In the mammary gland, E2 (either dose) or GEN increased proliferation and PR expression. Serum levels of luteinizing hormone were decreased by E2 (both doses) but not by GEN. Conclusions In summary, E2 and GEN share many effects in the studied organs, particularly in the vagina, uterus, and mammary gland but not in the hypothalamo/pituitary unit. PMID:18174952
Biltekin, Fatih; Yeginer, Mete; Ozyigit, Gokhan
2015-07-01
We analysed the effects of field size, depth, beam modifier and beam type on the amount of in-field and out-of-field neutron contamination for medical linear accelerators (linacs). Measurements were carried out for three high-energy medical linacs of Elekta Synergy Platform, Varian Clinac DHX High Performance and Philips SL25 using bubble detectors. The photo-neutron measurements were taken in the first two linacs with 18 MV nominal energy, whereas the electro-neutrons were measured in the three linacs with 9 MeV, 10 MeV, 15 MeV and 18 MeV. The central neutron doses increased with larger field sizes as a dramatic drop off was observed in peripheral areas. Comparing with the jaws-shaped open-field of 10 × 10 cm, the motorised and physical wedges contributed to neutron contamination at central axis by 60% and 18%, respectively. The similar dose increment was observed in MLC-shaped fields. The contributions of MLCs were in the range of 55-59% and 19-22% in Elekta and Varian linacs comparing with 10 × 10 and 20 × 20 cm open fields shaped by the jaws, respectively. The neutron doses at shallow depths were found to be higher than the doses found at deeper regions. The electro-neutron dose at the 18 MeV energy was higher than the doses at the electron energies of 15 MeV and 9 MeV by a factor of 3 and 50, respectively. The photo- and electro-neutron dose should be taken into consideration in the radiation treatment with high photon and electron energies. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J
2016-01-01
Aim Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients and methods Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3–6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. Results In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. Conclusion There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered. PMID:27274277
Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J
2016-01-01
Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3-6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered.
Does high dose vitamin D supplementation enhance cognition?: A randomized trial in healthy adults.
Pettersen, Jacqueline A
2017-04-01
Insufficiency of 25-hydroxyvitamin D [25(OH)D] has been associated with dementia and cognitive decline. However, the effects of vitamin D supplementation on cognition are unclear. It was hypothesized that high dose vitamin D3 supplementation would result in enhanced cognitive functioning, particularly among adults whose 25(OH)D levels were insufficient (<75nmol/L) at baseline. Healthy adults (n=82) from northern British Columbia, Canada (54° north latitude) with baseline 25(OH)D levels ≤100nmol/L were randomized and blinded to High Dose (4000IU/d) versus Low Dose (400IU/d) vitamin D3 (cholecalciferol) for 18weeks. Baseline and follow-up serum 25(OH)D and cognitive performance were assessed and the latter consisted of: Symbol Digit Modalities Test, verbal (phonemic) fluency, digit span, and the CANTAB® computerized battery. There were no significant baseline differences between Low (n=40) and High (n=42) dose groups. Serum 25(OH)D increased significantly more in the High Dose (from 67.2±20 to 130.6±26nmol/L) than the Low Dose group (60.5±22 to 85.9±16nmol/L), p=0.0001. Performance improved in the High Dose group on nonverbal (visual) memory, as assessed by the Pattern Recognition Memory task (PRM), from 84.1±14.9 to 88.3±13.2, p=0.043 (d=0.3) and Paired Associates Learning Task, (PAL) number of stages completed, from 4.86±0.35 to 4.95±0.22, p=0.044 (d=0.5), but not in the Low Dose Group. Mixed effects modeling controlling for age, education, sex and baseline performance revealed that the degree of improvement was comparatively greater in the High Dose Group for these tasks, approaching significance: PRM, p=0.11 (d=0.4), PAL, p=0.058 (d=0.4). Among those who had insufficient 25(OH)D (<75nmol/L) at baseline, the High Dose group (n=23) improved significantly (p=0.005, d=0.7) and to a comparatively greater degree on the PRM (p=0.025, d=0.6). Nonverbal (visual) memory seems to benefit from higher doses of vitamin D supplementation, particularly among those who are insufficient (<75nmol/L) at baseline, while verbal memory and other cognitive domains do not. These findings are consistent with recent cross-sectional and longitudinal studies, which have demonstrated significant positive associations between 25(OH)D levels and nonverbal, but not verbal, memory. While our findings require confirmation, they suggest that higher 25(OH)D is particularly important for higher level cognitive functioning, specifically nonverbal (visual) memory, which also utilizes executive functioning processes. Copyright © 2017 Elsevier Inc. All rights reserved.
Acute changes in the central nervous system of monkeys exposed to protons.
NASA Technical Reports Server (NTRS)
Haymaker, W.; Ibrahim, M. Z. M.; Miquel, J.; Call, N.; Noden, P.; Ashley, W.; Ballinger, E. R.; Ghidoni, J.; Lindsay, I. R.; Behar, A. J.
1972-01-01
Study of the changes occurring in simian brain exposed to protons of varied energy, given in wide dose and dose-rate ranges. Results show that inflammatory reaction and glycogen accumulation in astrocytes occurred practically in all animals. Cerebral cortical necrosis, granule cell pyknosis, and inflammatory reaction occurred at doses far lower than effective for high-energy gamma radiation given other series of monkeys at comparable dose rates. Metallic impregnation, carried out in virtually all the animals tested, revealed a wide variation in glial response even at equal doses and dose rates in the same proton energy series. Proton energy effect, dose effect, dose-time effect, and dose-rate effect were evident in the various morphological categories investigated, but inconsistencies were encountered.
Cini, Michela; Legnani, Cristina; Cosmi, Benilde; Guazzaloca, Giuliana; Valdrè, Lelia; Frascaro, Mirella; Palareti, Gualtiero
2012-08-01
Warfarin dosing is affected by clinical and genetic variants, but the contribution of the genotype associated with warfarin resistance in pharmacogenetic algorithms has not been well assessed yet. We developed a new dosing algorithm including polymorphisms associated both with warfarin sensitivity and resistance in the Italian population, and its performance was compared with those of eight previously published algorithms. Clinical and genetic data (CYP2C9*2, CYP2C9*3, VKORC1 -1639 G > A, and VKORC1 3730 G > A) were used to elaborate the new algorithm. Derivation and validation groups comprised 55 (58.2% men, mean age 69 years) and 40 (57.5% men, mean age 70 years) patients, respectively, who were on stable anticoagulation therapy for at least 3 months with different oral anticoagulation therapy (OAT) indications. Performance of the new algorithm, evaluated with mean absolute error (MAE) defined as the absolute value of the difference between observed daily maintenance dose and predicted daily dose, correlation with the observed dose and R(2) value, was comparable with or slightly lower than that obtained using the other algorithms. The new algorithm could correctly assign 53.3%, 50.0%, and 57.1% of patients to the low (≤25 mg/week), intermediate (26-44 mg/week) and high (≥ 45 mg/week) dosing range, respectively. Our data showed a significant increase in predictive accuracy among patients requiring high warfarin dose compared with the other algorithms (ranging from 0% to 28.6%). The algorithm including VKORC1 3730 G > A, associated with warfarin resistance, allowed a more accurate identification of resistant patients who require higher warfarin dosage.
Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radev, R
2009-01-13
In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less
Choi, Sun Young; Hong, Ji Yeon; Ko, Eun Jung; Kim, Beom Joon; Hong, Sung-Woon; Lim, Mi Hyoung; Yeon, Sung Hum; Son, Rak Ho
2018-02-01
Oxidative stress and photodamage resulting from ultraviolet radiation exposure play key roles in skin aging. Fermented Cyclopia intermedia, which is used to brew honeybush tea, exerts antioxidant and anti-wrinkle effects by inhibiting reactive oxygen species production and downregulating matrix metalloproteinase activity. This randomized, double-blinded, placebo-controlled study aimed to evaluate the efficacy and safety of fermented honeybush (Cyclopia intermedia) extract (HU-018) for skin rejuvenation. 120 Korean subjects with crow's feet wrinkles were randomized to receive either low-dose extract (400 mg/day), high-dose extract (800 mg/day), or placebo (negative control, only dextran) for 12 weeks. Wrinkles were evaluated using JANUS ® and PRIMO pico ® . Skin elasticity, hydration and transepidermal water loss were measured. Global skin wrinkle grade was significantly improved in both low-dose and high-dose groups compared to placebo group, as well as for skin hydration and elasticity. Both the low- and high-dose groups showed significantly decreased TEWL compared to the placebo group. There were no adverse effects during the entire study period. Our data indicate that HU-018 is effective for improving skin wrinkles, elasticity, and hydration. Therefore, daily supplementation with fermented honeybush could be helpful for protecting against skin aging.
Melchert, Corinna; Kovács, György
2016-01-01
Purpose This study aims to compare the dosimetric data of local tumor's bed dose escalation (boost) with photon beams (external beam radiation therapy – EBRT) versus high-dose-rate interstitial brachytherapy (HDR-BT) after breast-conserving treatment in women with early-stage breast cancer. Material and methods We analyzed the treatment planning data of 136 irradiated patients, treated between 2006 and 2013, who underwent breast-conserving surgery and adjuvant whole breast irradiation (WBI; 50.4 Gy) and boost (HDR-BT: 10 Gy in one fraction [n = 36]; EBRT: 10 Gy in five fractions [n = 100]). Organs at risk (OAR; heart, ipsilateral lung, skin, most exposed rib segment) were delineated. Dosimetric parameters were calculated with the aid of dose-volume histograms (DVH). A non-parametric test was performed to compare the two different boost forms. Results There was no difference for left-sided cancers regarding the maximum dose to the heart (HDR-BT 29.8% vs. EBRT 29.95%, p = 0.34). The maximum doses to the other OAR were significantly lower for HDR-BT (Dmax lung 47.12% vs. 87.7%, p < 0.01; rib 61.17% vs. 98.5%, p < 0.01; skin 57.1% vs. 94.75%, p < 0.01; in the case of right-sided breast irradiation, dose of the heart 6.00% vs. 16.75%, p < 0.01). Conclusions Compared to EBRT, local dose escalation with HDR-BT presented a significant dose reduction to the investigated OAR. Only left-sided irradiation showed no difference regarding the maximum dose to the heart. Reducing irradiation exposure to OAR could result in a reduction of long-term side effects. Therefore, from a dosimetric point of view, an interstitial boost complementary to WBI via EBRT seems to be more advantageous in the adjuvant radiotherapy of breast cancer. PMID:27648082
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Renu; Jursinic, Paul A.
2013-07-15
Purpose: To show the feasibility of clinical implementation of OSLDs for high dose-rate (HDR) in vivo dosimetry for gynecological and breast patients. To discuss how the OSLDs were characterized for an Ir-192 source, taking into account low gamma energy and high dose gradients. To describe differences caused by the dose calculation formalism of treatment planning systems.Methods: OSLD irradiations were made using the GammaMedplus iX Ir-192 HDR, Varian Medical Systems, Milpitas, CA. BrachyVision versions 8.9 and 10.0, Varian Medical Systems, Milpitas, CA, were used for calculations. Version 8.9 used the TG-43 algorithm and version 10.0 used the Acuros algorithm. The OSLDsmore » (InLight Nanodots) were characterized for Ir-192. Various phantoms were created to assess calculated and measured doses and the angular dependence and self-absorption of the Nanodots. Following successful phantom measurements, patient measurements for gynecological patients and breast cancer patients were made and compared to calculated doses.Results: The OSLD sensitivity to Ir-192 compared to 6 MV is between 1.10 and 1.25, is unique to each detector, and changes with accumulated dose. The measured doses were compared to those predicted by the treatment planning system and found to be in agreement for the gynecological patients to within measurement uncertainty. The range of differences between the measured and Acuros calculated doses was -10%-14%. For the breast patients, there was a discrepancy of -4.4% to +6.5% between the measured and calculated doses at the skin surface when the Acuros algorithm was used. These differences were within experimental uncertainty due to (random) error in the location of the detector with respect to the treatment catheter.Conclusions: OSLDs can be successfully used for HDR in vivo dosimetry. However, for the measurements to be meaningful one must account for the angular dependence, volume-averaging, and the greater sensitivity to Ir-192 gamma rays than to 6 MV x-rays if 6 MV x-rays were used for OSLD calibration. The limitations of the treatment planning algorithm must be understood, especially for surface dose measurements. Use of in vivo dosimetry for HDR brachytherapy treatments is feasible and has the potential to detect and prevent gross errors. In vivo HDR brachytherapy should be included as part of the QA for a HDR brachytherapy program.« less
Cost-effectiveness of high-dose atorvastatin compared with regular dose simvastatin.
Lindgren, Peter; Graff, Jennifer; Olsson, Anders G; Pedersen, Terje J; Jönsson, Bengt
2007-06-01
The aim of the study was to evaluate the long-term cost-effectiveness of high-dose atorvastatin when compared with generic simvastatin for secondary prevention in Denmark, Finland, Norway, and Sweden based on the recently completed IDEAL trial. The IDEAL trial showed that high-dose treatment with atorvastatin was associated with fewer non-fatal myocardial infarctions (MI) or coronary heart disease death (RR 0.89; 95% CI 0.78-1.01) and major cardiovascular events by (RR 0.87; 95% CI 0.77-0.98) or any coronary event (RR 0.84; 95% CI 0.76-0.91) than simvastatin with no significant difference in the number of serious adverse events. Costs during the trial period was estimated based on the trial data and a Markov model was constructed where the risk of MIs and revascularization procedures and the long-term costs, quality of life, and mortality associated with these events was simulated. Costs were based on resource consumptions recorded in the trial multiplied with recent unit costs from each country. Both direct health care costs and indirect costs (costs from lost production due to work absence) were included. Intervention lasted for the duration of the trial (4.8 years) while health-effects and costs are predicted for the lifespan of the patient. The main outcome was quality adjusted life-years (QALY) gained. High-dose treatment was predicted to lead to a mean increase in survival of 0.049 years per patient and 0.033 QALYs gained. The cost to gain one QALY was predicted to 47,197euro (Denmark), 62,639euro (Finland), 35,210euro (Norway), and 43,667euro (Sweden), with cost-effectiveness ratio decreasing with higher risk. In the prevention of cardiovascular events among patients with a previous MI, high-dose atorvastatin appears to be a cost-effective strategy when compared with generic simvastatin 20-40 mg in Denmark, Norway, and Sweden. In Finland, it is cost-effective in high-risk patients. The key driver of the cost-effectiveness is the price-difference between 80 mg atorvastatin and generic simvastatin.
Chan, Tabitha Y; Tan, Poh Wee; Tan, Chek Wee; Tang, Johann I
2015-12-01
This study aims to quantify dosimetric reduction to the left anterior descending (LAD) artery, heart and lung when comparing whole breast external beam radiotherapy (WBEBRT) with multicatheter accelerated partial breast irradiation (MCABPI) for early stage left breast cancer. Planning CT data sets of 15 patients with left breast cancer receiving multicatheter brachytherapy post breast conserving surgery were used to create two independent treatment plans - WBEBRT prescribed to 50 Gy/25 fractions and MCABPI prescribed to 34 Gy/10 fractions. Dose parameters for (i) LAD artery, (ii) heart, and (iii) ipsilateral lung were calculated and compared between the two treatment modalities. After adjusting for Equivalent Dose in 2 Gy fractions(EQD2), and comparing MCAPBI with WBEBRT, the largest dose reduction was for the LAD artery whose mean dose differed by a factor of 7.7, followed by the ipsilateral lung and heart with a factor of 4.6 and 2.6 respectively. Compared to WBEBRT, the mean MCAPBI LAD was significantly lower compared to WBEBRT (6.0 Gy vs 45.9 Gy; p<0.01). Mean MCAPBI heart D(0.1cc) (representing the dose received by the most highly exposed 0.1 cc of the risk organ, i.e. the dose peak) was significantly lower (16.3 Gy vs 50.6 Gy; p<0.01). Likewise, the mean heart dose (MHD) was significantly lower (2.3 Gy vs 6.0 Gy; p<0.01). Peak dose and mean lung dose (MLD) for ipsilateral lung was also lower for MCAPBI compared to WBEBRT (Peak dose: 22.2 Gy vs 52.0 Gy; p<0.01; MLD: 2.3 Gy vs 10.7 Gy; p<0.01). Compared to WBEBRT, MCAPBI showed a significant reduction in radiation dose for the LAD, heart and lung. This may translate into better cardiac and pulmonary toxicities for patients undergoing MCAPBI. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juang, T; Adamovics, J; Oldham, M
Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, highmore » resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately measuring dose in a deforming structure, and warrants further study to quantify comprehensive accuracy at different levels of deformation. This work was supported by NIH R01CA100835. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.« less
Galgani, Ilaria; Bunge, Eveline M; Hendriks, Lisa; Schludermann, Christopher; Marano, Cinzia; De Moerlooze, Laurence
2017-09-01
Tick-borne encephalitis (TBE), which is endemic across large regions of Europe and Asia, is most effectively prevented through vaccination. Three-dose primary TBE vaccination schedules are either rapid (0,7,21-days) or conventional (0,28-84-days, 9-12-months). The second dose can also be administered at 14 days for faster priming and sero-protection). Areas covered: We used a three-step selection process to identify 21 publications comparing the immunogenicity and/or safety of different schedules. Expert commentary: Priming with two or three TBE vaccine doses was highly immunogenic. After conventional priming (0-28 days), 95% adults and ≥95% children had neutralization test (NT) titers ≥10 at 14 days post-dose-2 compared with 92% adults and 99% children at 21 days post-dose-3 (rapid schedule). Most subjects retained NT titers ≥10 at day 300. A single booster dose induced a strong immune response in all subjects irrespective of primary vaccination schedule or elapsed time since priming. GMT peaked at 42 days post-dose-1 (i.e., 21 days post-dose 3 [rapid-schedule], or 14-28 days post-dose-2 [conventional-schedule]), and declined thereafter. Adverse events were generally rare and declined with increasing doses. In the absence of data to recommend one particular schedule, the regimen choice will remain at the physician's discretion, based on patient constraints and availability.
Iaconelli, Carla Andrade Rebello; Setti, Amanda Souza; Braga, Daniela Paes Almeida Ferreira; Maldonado, Luiz Guilherme Louzada; Iaconelli, Assumpto; Borges, Edson; Aoki, Tsutomu
2017-12-01
The objective of this study was to investigate the effects of low-dose hCG supplementation on ICSI outcomes and controlled ovarian stimulation (COS) cost. Three hundred and thirty patients undergoing ICSI were split into groups according to the COS protocol: (i) control group (n = 178), including patients undergoing conventional COS treatment; and (ii) low-dose hCG group (n = 152), including patients undergoing COS with low-dose hCG supplementation. Lower mean total doses of FSH administered and higher mean oestradiol level and mature oocyte rates were observed in the low-dose hCG group. A significantly higher fertilization rate, high-quality embryo rate and blastocyst formation rate were observed in the low-dose hCG group as compared to the control group. The miscarriage rate was significantly higher in the control group compared to the low-dose hCG group. A significantly lower incidence of OHSS was observed in the low-dose hCG group. There was also a significantly lower gonadotropin cost in the low-dose hCG group as compared to the control group ($1235.0 ± 239.0×$1763.0 ± 405.3, p < 0.001). The concomitant use of low-dose hCG and FSH results in a lower abortion rate and increased number of mature oocytes retrieved, as well as improved oocyte quality, embryo quality and blastocyst formation and reduced FSH requirements.
Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans
Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.
2012-01-01
BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498
Rapid Acute Dose Assessment Using MCNP6
NASA Astrophysics Data System (ADS)
Owens, Andrew Steven
Acute radiation doses due to physical contact with a high-activity radioactive source have proven to be an occupational hazard. Multiple radiation injuries have been reported due to manipulating a radioactive source with bare hands or by placing a radioactive source inside a shirt or pants pocket. An effort to reconstruct the radiation dose must be performed to properly assess and medically manage the potential biological effects from such doses. Using the reference computational phantoms defined by the International Commission on Radiological Protection (ICRP) and the Monte Carlo N-Particle transport code (MCNP6), dose rate coefficients are calculated to assess doses for common acute doses due to beta and photon radiation sources. The research investigates doses due to having a radioactive source in either a breast pocket or pants back pocket. The dose rate coefficients are calculated for discrete energies and can be used to interpolate for any given energy of photon or beta emission. The dose rate coefficients allow for quick calculation of whole-body dose, organ dose, and/or skin dose if the source, activity, and time of exposure are known. Doses are calculated with the dose rate coefficients and compared to results from the International Atomic Energy Agency (IAEA) reports from accidents that occurred in Gilan, Iran and Yanango, Peru. Skin and organ doses calculated with the dose rate coefficients appear to agree, but there is a large discrepancy when comparing whole-body doses assessed using biodosimetry and whole-body doses assessed using the dose rate coefficients.
Devidas, Meenakshi; Chen, Si; Salzer, Wanda L.; Raetz, Elizabeth A.; Loh, Mignon L.; Mattano, Leonard A.; Cole, Catherine; Eicher, Alisa; Haugan, Maureen; Sorenson, Mark; Heerema, Nyla A.; Carroll, Andrew A.; Gastier-Foster, Julie M.; Borowitz, Michael J.; Wood, Brent L.; Willman, Cheryl L.; Winick, Naomi J.; Hunger, Stephen P.; Carroll, William L.
2016-01-01
Purpose Survival for children and young adults with high-risk B-acute lymphoblastic leukemia has improved significantly, but 20% to 25% of patients are not cured. Children’s Oncology Group study AALL0232 tested two interventions to improve survival. Patients and Methods Between January 2004 and January 2011, AALL0232 enrolled 3,154 participants 1 to 30 years old with newly diagnosed high-risk B-acute lymphoblastic leukemia. By using a 2 × 2 factorial design, 2,914 participants were randomly assigned to receive dexamethasone (14 days) versus prednisone (28 days) during induction and high-dose methotrexate versus Capizzi escalating-dose methotrexate plus pegaspargase during interim maintenance 1. Results Planned interim monitoring showed the superiority of the high-dose methotrexate regimens, which exceeded the predefined boundary and led to cessation of enrollment in January 2011. At that time, participants randomly assigned to high-dose methotrexate during interim maintenance 1 versus those randomly assigned to Capizzi methotrexate had a 5-year event-free survival (EFS) of 82% versus 75.4% (P = .006). Mature final data showed 5-year EFS rates of 79.6% for high-dose methotrexate and 75.2% for Capizzi methotrexate (P = .008). High-dose methotrexate decreased both marrow and CNS recurrences. Patients 1 to 9 years old who received dexamethasone and high-dose methotrexate had a superior outcome compared with those who received the other three regimens (5-year EFS, 91.2% v 83.2%, 80.8%, and 82.1%; P = .015). Older participants derived no benefit from dexamethasone during induction and experienced excess rates of osteonecrosis. Conclusion High-dose methotrexate is superior to Capizzi methotrexate for the treatment of high-risk B-acute lymphoblastic leukemia, with no increase in acute toxicity. Dexamethasone given during induction benefited younger children but provided no benefit and was associated with a higher risk of osteonecrosis among participants 10 years and older. PMID:27114587
Brigo, Francesco; Bragazzi, Nicola Luigi; Nardone, Raffaele; Trinka, Eugen
2016-11-01
Brivaracetam (BRV), eslicarbazepine acetate (ESL), lacosamide (LCM), and perampanel (PER) have been recently marketed as adjunctive treatments for focal onset seizures. To date, no randomized controlled trial (RCT) has directly compared BRV with ESL, LCM, or PER. To compare BRV with the other add-on AEDs in patients with uncontrolled focal epilepsy, estimating their efficacy and tolerability through an adjusted, common-reference based indirect comparison meta-analysis. We systematically searched RCTs in which add-on treatment with ESL or LCM in patients with focal onset seizures have been compared with placebo. Efficacy and tolerability outcomes were considered. Random-effects Mantel-Haenszel meta-analyses were performed to obtain odds ratios (ORs) for the efficacy of BRV, LCM, ESL, or PER versus placebo. Adjusted indirect comparisons were then made between BRV and the other three AEDs using the obtained results, comparing the minimum and the highest effective recommended daily dose of each drug. Seventeen RCTs, with a total of 4971 patients were included. After adjusting for dose-effects, indirect comparisons showed no difference between BRV and LCM, ESL, or PER for responder rate and seizure freedom. Lower adverse events were observed with high dose BRV compared to high dose ESL or PER, but no difference was found in withdrawing because of adverse events. Indirect comparisons do not demonstrate a significant difference in efficacy between add-on BRV and LCM, ESL, or PER in focal epilepsy, and might suggest a better tolerability of BRV than ESL, and possibly also PER, at the highest effective recommended dose. Copyright © 2016 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Direct Measurement of Perchlorate Exposure Biomarkers in a Highly Exposed Population: A Pilot Study
Wong, Michelle; Copan, Lori; Olmedo, Luis; Patton, Sharyle; Haas, Robert; Atencio, Ryan; Xu, Juhua; Valentin-Blasini, Liza
2011-01-01
Exposure to perchlorate is ubiquitous in the United States and has been found to be widespread in food and drinking water. People living in the lower Colorado River region may have perchlorate exposure because of perchlorate in ground water and locally-grown produce. Relatively high doses of perchlorate can inhibit iodine uptake and impair thyroid function, and thus could impair neurological development in utero. We examined human exposures to perchlorate in the Imperial Valley among individuals consuming locally grown produce and compared perchlorate exposure doses to state and federal reference doses. We collected 24-hour urine specimen from a convenience sample of 31 individuals and measured urinary excretion rates of perchlorate, thiocyanate, nitrate, and iodide. In addition, drinking water and local produce were also sampled for perchlorate. All but two of the water samples tested negative for perchlorate. Perchlorate levels in 79 produce samples ranged from non-detect to 1816 ppb. Estimated perchlorate doses ranged from 0.02 to 0.51 µg/kg of body weight/day. Perchlorate dose increased with the number of servings of dairy products consumed and with estimated perchlorate levels in produce consumed. The geometric mean perchlorate dose was 70% higher than for the NHANES reference population. Our sample of 31 Imperial Valley residents had higher perchlorate dose levels compared with national reference ranges. Although none of our exposure estimates exceeded the U. S. EPA reference dose, three participants exceeded the acceptable daily dose as defined by bench mark dose methods used by the California Office of Environmental Health Hazard Assessment. PMID:21394205
Davis, Angela M; Mao, Jiude; Naz, Bushra; Kohl, Jessica A; Rosenfeld, Cheryl S
2008-10-01
Selective estrogen receptor modulators (SERMs) are potentially useful in treating various endometrial disorders, including endometrial cancer, as they block some of the detrimental effects of estrogen. It remains unclear whether each SERM regulates a unique subset of genes and, if so, whether the combination of a SERM and 17beta-estradiol has an additive or synergistic effect on gene expression. We performed microarray analysis with Affymetrix Mouse Genome 430 2.0 short oligomer arrays to determine gene expression changes in uteri of ovariectomized mice treated with estradiol (low and high dose), methyl-piperidino-pyrazole (MPP), ICI 182 780, raloxifene, and combinations of high dose of estradiol with one of the SERM and dimethyl sulfoxide (DMSO) vehicle control. The nine treatments clustered into two groups, with MPP, raloxifene, and high dose of estradiol in one, and low dose of estradiol, ICI + estradiol, ICI, MPP + estradiol, and raloxifene + estradiol in the second group. Surprisingly, combining a high dose of estradiol with a SERM markedly increased (P<0.02) the number of regulated genes compared with each individual treatment. Analysis of expression for selected genes in uteri of estradiol and SERM-treated mice by quantitative (Q)RT-PCR generally supported the microarray results. For some cancer-associated genes, including Klk1, Ihh, Cdc45l, and Cdca8, administration of MPP or raloxifene with estradiol resulted in greater expression than estradiol alone (P<0.05). By contrast, ICI 182 780 suppressed more genes governing DNA replication compared with MPP and raloxifene treatments. Therefore, ICI 182 780 might be superior to MPP and raloxifene to treat estrogen-induced endometrial cancer in women.
XU, XIAOPING; LI, XIAOHUA; ZHANG, LEI; LIU, ZHAOHUI; PAN, YUAN; CHEN, DONG; BIN, DONGHUA; DENG, QUN; SUN, YU; HOFFMAN, M. ROBERT; YANG, ZHIJIAN; YUAN, HONG
2017-01-01
Background/Aim: Hemorrhoidectomy is often associated with significant postoperative complications that may result in slow wound healing. The traditional Chinese medicine (TCM) compound Sophora flavescens (CSF) has shown efficacy on many inflammatory disorders. The aim of the present study was to examine the efficacy of CSF on wound healing in a rat model of perianal ulceration. Materials and Methods: A rat model of perianal ulceration was induced by subcutaneous injection of 75% glacial acetic acid. The animals with induced perianal ulcer received topical treatment of low, medium, and high doses of CFS twice daily. Potassium permanganate (PP); 0.02%) was given to the animals for comparison. Macroscopic and histological assessments of the ulcerated area were performed after treatment. The expression of pro-inflammatory cytokines prostaglandin E2 (PGE2) and interleukin-8 (IL-8) was detected by immunohistochemical analysis. Results: Topical administration of medium- and high-dose CSF significantly enhanced perianal ulcer healing as compared to the untreated control (p<0.05). The macroscopic ulceration score was significantly reduced only in the high-dose CSF-treated group as compared to the control (p<0.01). All doses of CSF and PP ameliorated histological damages in the rats with induced perianal ulceration. High-dose CSF or PP significantly reduced the expression of PGE2 and IL-8 as compared to the control (p<0.01). No treatment-related toxicity was found in either the CSF- or the PP-treated mice. Conclusion: CSF enhances wound healing in a rat model of perianal ulceration. The inhibitory effect of CSF on pro-inflammatory cytokines PGE2 and IL-8 may be involved in the mechanism of enhanced wound-healing. PMID:28652418
Xu, Xiaoping; Li, Xiaohua; Zhang, Lei; Liu, Zhaohui; Pan, Yuan; Chen, Dong; Bin, Donghua; Deng, Qun; Sun, Y U; Hoffman, Robert M; Yang, Zhijian; Yuan, Hong
2017-01-01
Hemorrhoidectomy is often associated with significant postoperative complications that may result in slow wound healing. The traditional Chinese medicine (TCM) compound Sophora flavescens (CSF) has shown efficacy on many inflammatory disorders. The aim of the present study was to examine the efficacy of CSF on wound healing in a rat model of perianal ulceration. A rat model of perianal ulceration was induced by subcutaneous injection of 75% glacial acetic acid. The animals with induced perianal ulcer received topical treatment of low, medium, and high doses of CFS twice daily. Potassium permanganate (PP); 0.02%) was given to the animals for comparison. Macroscopic and histological assessments of the ulcerated area were performed after treatment. The expression of pro-inflammatory cytokines prostaglandin E 2 (PGE 2 ) and interleukin-8 (IL-8) was detected by immunohistochemical analysis. Topical administration of medium- and high-dose CSF significantly enhanced perianal ulcer healing as compared to the untreated control (p<0.05). The macroscopic ulceration score was significantly reduced only in the high-dose CSF-treated group as compared to the control (p<0.01). All doses of CSF and PP ameliorated histological damages in the rats with induced perianal ulceration. High-dose CSF or PP significantly reduced the expression of PGE 2 and IL-8 as compared to the control (p<0.01). No treatment-related toxicity was found in either the CSF- or the PP-treated mice. CSF enhances wound healing in a rat model of perianal ulceration. The inhibitory effect of CSF on pro-inflammatory cytokines PGE 2 and IL-8 may be involved in the mechanism of enhanced wound-healing. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Gwynn, Justin P; Nalbandyan, Anna; Rudolfsen, Geir
2013-02-01
This paper discusses activity concentrations of (210)Po, (210)Pb, (40)K and (137)Cs in edible wild berries and mushrooms collected from Øvre Dividalen national park, Northern Norway and derives committed effective ingestion doses to man based on high consumption rates of these wild foods. Edible wild berries and mushrooms accumulated similar levels of (210)Pb, but mushrooms accumulated higher levels of (210)Po and (40)K than berries. There appears to be a clear difference in the ability of Leccinum spp. of fungi to accumulate (210)Po and/or translocate (210)Po to mushrooms compared to Russula spp. of fungi. Activity concentrations of (137)Cs in edible wild berries and mushrooms from Øvre Dividalen national park reflected the lower levels of fallout of this radionuclide in Northern Norway compared to more central areas following the Chernobyl accident. For mushrooms, ingestion doses are dominated by (210)Po, while for berries, (40)K is typically the main contributor to dose. Based on high consumption rates, ingestion doses arising from the combination of (210)Po, (210)Pb and (40)K were up to 0.05 mSv/a for berries and 0.50 mSv/a for mushrooms. Consumption of such wild foods may result in a significant contribution to total annual doses when consumed in large quantities, particularly when selecting mushrooms species that accumulate high activity concentrations of (210)Po. Copyright © 2012 Elsevier Ltd. All rights reserved.
Dose-dependent effects of vitamin 1,25(OH)2D3 on oxidative stress and apoptosis.
Cakici, Cagri; Yigitbasi, Turkan; Ayla, Sule; Karimkhani, Hadi; Bayramoglu, Feyza; Yigit, Pakize; Kilic, Ertugrul; Emekli, Nesrin
2018-02-08
Background The purpose of this study is to examine the dose-dependent effects of vitamin 1,25(OH)2D3 on apoptosis and oxidative stress. Methods In this study, 50 male Balb/c mice were used as control and experiment groups. The mice were divided into 5 groups each consisting of 10 mice. Calcitriol was intraperitoneally administered as low dose, medium dose, medium-high dose and high dose vitamin D groups (at 0.5, 1, 5 and 10 μg/kg, respectively), for three times a week during 14 days. At the end of the study, annexin V was measured by enzyme-linked immunosorbent assay method, and total antioxidant capacity and total oxidant status values were measured by colorimetric method in serum. Hematoxylin eosin staining was performed in liver tissues and periodic acid schiff staining was performed in kidney tissues. Results While comparing the results of medium-high dose (5 μg/kg) and high dose (10 μg/kg) vitamin D administration to that of the control group, it was observed that serum antioxidant status and annexin V levels decreased and glomerular mesenchial matrix ratio increased in kidney (p<0.05). In addition to these findings, in the group receiving high dose vitamin D (10 μg/kg), it was observed that the damage to the liver increased together with the the oxidative stress index values (p<0.05). Conclusions As a result, this study was the first in the literature to report that use of high-dose vitamin D (10 μg/kg) results in oxidant effect, rather than being an antioxidant, and causes severe histopathological toxicity in the liver and kidney.
Low dose radiation interactions with the transformation growth factor (TFG)-beta pathway
NASA Astrophysics Data System (ADS)
Maslowski, Amy Jesse
A major limiting factor for long-term, deep-space missions is the radiation dose to astronauts. Because the dose to the astronauts is a mixed field of low- and high-LET radiation, there is a need to understand the effects of both radiation types on whole tissue; however, there are limited published data on the effects of high-LET (linear-energy-transfer) radiation on tissue. Thus, we designed a perfusion chamber system for rat trachea in order to mimic in vivo respiratory tissue. We successfully maintained the perfused tracheal tissue ex vivo in a healthy and viable condition for up to three days. In addition, this project studied the effects of high-LET Fe particles on the overall transformation growth factor (TGF)-beta response after TGF-beta inactivation and compared the results to the TGF-beta response post x-ray irradiation. It was found that a TGF-beta response could be measured in the perfused tracheal tissue, for x-ray and Fe particle irradiations, despite the high autofluorescent background intrinsic to tissue. However, after comparing the TGF-beta response of x-ray irradiation to High-Z-High-energy (HZE) irradiation, there was not a significant difference in radiation types. The TGF-beta response in x-ray and HZE irradiated perfusion chambers was also measured over time post irradiation. It was found that for 6 hour and 8 hour post irradiation, the TGF-beta response was higher for lower doses of radiation than for higher doses. This is in contrast to the 0 hour fixation which found the TGF-beta response to increase with increased dose. The inverse relationship found for 6 hour and 8 hour fixation times may indicate a threshold response for TGF-beta response; i.e., for low doses, a threshold of dose must be reached for an immediate TGF-beta response, otherwise the tissue responds more slowly to the irradiation damage. This result was unexpected and will require further investigation to determine if the threshold can be determined for the 250 kVp x-rays and 1 Gev Fe particles.
Suru, Stephen M; Ugwu, Chidiebere E
2015-07-01
Despite growing claims of functional health benefits in folkloric medicine, the safety of chronic/elevated intakes of onion and garlic cannot be assumed. Therefore, this study assesses oral administration of varied doses of onion and garlic on some biomarkers of hepatic and renal functions in rats. Animals were divided into five groups: control group received vehicle and extract-treated groups received varied doses of onion or garlic extract (0.5 mL and 1.0 mL/100 g bwt/day) for 6 weeks. Both doses of onion caused marked (p<0.05) increase in hepatic and renal levels of glutathione (GSH), glutathione S-transferase (GST), superoxide dismutase (SOD), catalase (CAT) and marked (p<0.05) decrease in malondialdehyde (MDA). Treatment with low dose of garlic elicited similar trend except in hepatic CAT, renal SOD and GST levels. A high dose of garlic only caused marked (p<0.05) increase in hepatic GST, renal GST, and SOD. Both doses of onion and low dose of garlic significantly (p<0.05) enhanced renal Na+/K+-ATPase activity. Only a high dose of onion caused significant (p<0.05) increase in hepatic aspartate transaminase (AST), alkaline phosphatase (ALP), and decrease in plasma AST activities. These findings suggest antioxidant enhancing capability for both doses of onion and low dose of garlic, while high dose of garlic elicited pro-oxidant conditions.
NASA Astrophysics Data System (ADS)
Karunakara, N.; Yashodhara, I.; Sudeep Kumara, K.; Tripathi, R. M.; Menon, S. N.; Kadam, S.; Chougaonkar, M. P.
Indoor and outdoor gamma dose rates were evaluated around a prospective uranium mining region - Gogi, South India through (i) direct measurements using a GM based gamma dose survey meter, (ii) integrated measurement days using CaSO4:Dy based thermo luminescent dosimeters (TLDs), and (iii) analyses of 273 soil samples for 226Ra, 232Th, and 40K activity concentration using HPGe gamma spectrometry. The geometric mean values of indoor and outdoor gamma dose rates were 104 nGy h-1 and 97 nGy h-1, respectively with an indoor to outdoor dose ratio of 1.09. The gamma dose rates and activity concentrations of 226Ra, 232Th, and 40K varied significantly within a small area due to the highly localized mineralization of the elements. Correlation study showed that the dose estimated from the soil radioactivity is better correlated with that measured directly using the portable survey meter, when compared to that obtained from TLDs. This study showed that in a region having localized mineralization in situ measurements using dose survey meter provide better representative values of gamma dose rates.
Hodgson, Sam; Larvin, Joseph T; Dearman, Charles
2015-09-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: what dose of tranexamic acid is most effective and safe for adult patients undergoing cardiac surgery? Altogether 586 papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Current evidence shows clinical benefit of using high-dose tranexamic acid (>80 mg/kg total dose) as opposed to low-dose tranexamic acid (<50 mg/kg total dose) in cardiac surgery with cardiopulmonary bypass. Evidence from a large randomized controlled trial shows that patients receiving high-dose tranexamic acid lose less blood postoperatively than patients receiving low-dose tranexamic acid (590 vs 820 ml, P = 0.01). Patients receiving high-dose tranexamic acid also require fewer units of blood product transfusion (2.5 units vs 4.1 units; P = 0.02) and are less likely to undergo repeat surgery to achieve haemostasis. This effect is larger in those who are at high risk of bleeding. Several prospective studies comparing doses found no difference in clinical outcomes between high- and low-dose regimens, but excluded patients at high risk of bleeding. However, data from numerous observational studies demonstrate that tranexamic acid use is associated with an increased risk of postoperative seizure; one analysis showed tranexamic acid use to be a very strong independent predictor (odds ratio = 14.3, P < 0.001). There is also evidence that this risk of seizure is dose-dependent, with the greatest risk at higher doses of tranexamic acid. We conclude that, in general, patients with a high risk of bleeding should receive high-dose tranexamic acid, while those at low risk of bleeding should receive low-dose tranexamic acid with consideration given to potential dose-related seizure risk. We recommend the regimens of high-dose (30 mg kg(-1) bolus + 16 mg kg(-1) h(-1) + 2 mg kg(-1) priming) and low-dose (10 mg kg(-1) bolus + 1 mg kg(-1) h(-1) + 1 mg kg(-1) priming) tranexamic acid, as these are well established in terms of safety profile and have the strongest evidence for efficacy. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Omori, Yasutaka; Tokonami, Shinji; Sahoo, Sarata Kumar; Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Hosoda, Masahiro; Kudo, Hiromi; Pornnumpa, Chanis; Nair, Raghu Ram K; Jayalekshmi, Padmavaty Amma; Sebastian, Paul; Akiba, Suminori
2017-03-20
In order to evaluate internal exposure to radon and thoron, concentrations for radon, thoron, and thoron progeny were measured for 259 dwellings located in high background radiation areas (HBRAs, outdoor external dose: 3-5 mGy y -1 ) and low background radiation areas (control areas, outdoor external dose: 1 mGy y -1 ) in Karunagappally Taluk, Kerala, India. The measurements were conducted using passive-type radon-thoron detectors and thoron progeny detectors over two six-month measurement periods from June 2010 to June 2011. The results showed no major differences in radon and thoron progeny concentrations between the HBRAs and the control areas. The geometric mean of the annual effective dose due to radon and thoron was calculated as 0.10 and 0.44 mSv, respectively. The doses were small, but not negligible compared with the external dose in the two areas.
Optimization of the scan protocols for CT-based material extraction in small animal PET/CT studies
NASA Astrophysics Data System (ADS)
Yang, Ching-Ching; Yu, Jhih-An; Yang, Bang-Hung; Wu, Tung-Hsin
2013-12-01
We investigated the effects of scan protocols on CT-based material extraction to minimize radiation dose while maintaining sufficient image information in small animal studies. The phantom simulation experiments were performed with the high dose (HD), medium dose (MD) and low dose (LD) protocols at 50, 70 and 80 kVp with varying mA s. The reconstructed CT images were segmented based on Hounsfield unit (HU)-physical density (ρ) calibration curves and the dual-energy CT-based (DECT) method. Compared to the (HU;ρ) method performed on CT images acquired with the 80 kVp HD protocol, a 2-fold improvement in segmentation accuracy and a 7.5-fold reduction in radiation dose were observed when the DECT method was performed on CT images acquired with the 50/80 kVp LD protocol, showing the possibility to reduce radiation dose while achieving high segmentation accuracy.
Yuan, Hong; Zhang, Lei; Frank, Jonathan E; Inscoe, Christina R; Burk, Laurel M; Hadsell, Mike; Lee, Yueh Z; Lu, Jianping; Chang, Sha; Zhou, Otto
2015-09-01
Microbeam radiation treatment (MRT) using synchrotron radiation has shown great promise in the treatment of brain tumors, with a demonstrated ability to eradicate the tumor while sparing normal tissue in small animal models. With the goal of expediting the advancement of MRT research beyond the limited number of synchrotron facilities in the world, we recently developed a compact laboratory-scale microbeam irradiator using carbon nanotube (CNT) field emission-based X-ray source array technology. The focus of this study is to evaluate the effects of the microbeam radiation generated by this compact irradiator in terms of tumor control and normal tissue damage in a mouse brain tumor model. Mice with U87MG human glioblastoma were treated with sham irradiation, low-dose MRT, high-dose MRT or 10 Gy broad-beam radiation treatment (BRT). The microbeams were 280 μm wide and spaced at 900 μm center-to-center with peak dose at either 48 Gy (low-dose MRT) or 72 Gy (high-dose MRT). Survival studies showed that the mice treated with both MRT protocols had a significantly extended life span compared to the untreated control group (31.4 and 48.5% of life extension for low- and high-dose MRT, respectively) and had similar survival to the BRT group. Immunostaining on MRT mice demonstrated much higher DNA damage and apoptosis level in tumor tissue compared to the normal brain tissue. Apoptosis in normal tissue was significantly lower in the low-dose MRT group compared to that in the BRT group at 48 h postirradiation. Interestingly, there was a significantly higher level of cell proliferation in the MRT-treated normal tissue compared to that in the BRT-treated mice, indicating rapid normal tissue repairing process after MRT. Microbeam radiation exposure on normal brain tissue causes little apoptosis and no macrophage infiltration at 30 days after exposure. This study is the first biological assessment on MRT effects using the compact CNT-based irradiator. It provides an alternative technology that can enable widespread MRT research on mechanistic studies using a preclinical model, as well as further translational research towards clinical applications.
Krysiak, Robert; Kowalska, Beata; Żmuda, Witold; Okopień, Bogusław
2015-04-01
Aggressive statin treatment was found to slightly reduce testosterone production. The aim of this study was to compare the effects of ezetimibe-statin combination and high-dose statin therapy on testicular and adrenal cortex function in men with LDL cholesterol levels below 70 mg/dL. The study included 26 adult men with coronary artery disease. Twelve of these patients did not tolerate high-dose statin therapy and were treated with lower doses of a statin plus ezetimibe. Fourteen patients tolerating high-dose simvastatin or rosuvastatin treatment continued high-dose statin therapy throughout the study period. Plasma lipids, glucose homeostasis markers and plasma levels of testosterone, cortisol, dehydroepiandrosterone sulphate, sex hormone-binding globulin, gonadotropins and ACTH, as well as urine free cortisol were assessed at baseline and after 16 weeks of treatment. Replacing high-dose statin therapy with ezetimibe/statin combination therapy reduced plasma levels of LH by 32% (p=0.043), as well as increased plasma levels of testosterone by 20% (p=0.038). Ezetimibe/statin combination did not induce any significant changes in plasma levels or urine excretion of the remaining hormones. At the end of the study, plasma LH levels were higher, while plasma testosterone levels were lower in patients receiving the combination therapy than in those treated only with high-dose statin. Our results indicate that ezetimibe combined with moderate statin dose exerts a less pronounced effect on testicular function in comparison with high-dose statin therapy. Copyright © 2014 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel
2014-01-01
High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by 241Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy-1 for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy-1 achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production. PMID:24600167
Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel
2014-01-01
High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by (241)Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy(-1) for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy(-1) achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.
Adaptive intensity modulated radiotherapy for advanced prostate cancer
NASA Astrophysics Data System (ADS)
Ludlum, Erica Marie
The purpose of this research is to develop and evaluate improvements in intensity modulated radiotherapy (IMRT) for concurrent treatment of prostate and pelvic lymph nodes. The first objective is to decrease delivery time while maintaining treatment quality, and evaluate the effectiveness and efficiency of novel one-step optimization compared to conventional two-step optimization. Both planning methods are examined at multiple levels of complexity by comparing the number of beam apertures, or segments, the amount of radiation delivered as measured by monitor units (MUs), and delivery time. One-step optimization is demonstrated to simplify IMRT planning and reduce segments (from 160 to 40), MUs (from 911 to 746), and delivery time (from 22 to 7 min) with comparable plan quality. The second objective is to examine the capability of three commercial dose calculation engines employing different levels of accuracy and efficiency to handle high--Z materials, such as metallic hip prostheses, included in the treatment field. Pencil beam, convolution superposition, and Monte Carlo dose calculation engines are compared by examining the dose differences for patient plans with unilateral and bilateral hip prostheses, and for phantom plans with a metal insert for comparison with film measurements. Convolution superposition and Monte Carlo methods calculate doses that are 1.3% and 34.5% less than the pencil beam method, respectively. Film results demonstrate that Monte Carlo most closely represents actual radiation delivery, but none of the three engines accurately predict the dose distribution when high-Z heterogeneities exist in the treatment fields. The final objective is to improve the accuracy of IMRT delivery by accounting for independent organ motion during concurrent treatment of the prostate and pelvic lymph nodes. A leaf-shifting algorithm is developed to track daily prostate position without requiring online dose calculation. Compared to conventional methods of adjusting patient position, adjusting the multileaf collimator (MLC) leaves associated with the prostate in each segment significantly improves lymph node dose coverage (maintains 45 Gy compared to 42.7, 38.3, and 34.0 Gy for iso-shifts of 0.5, 1 and 1.5 cm). Altering the MLC portal shape is demonstrated as a new and effective solution to independent prostate movement during concurrent treatment.
Castberg, Ingrid; Spigset, Olav
2008-10-01
The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two patients were admitted in the period from January 2000 to December 2005. All available samples were used when comparing serum concentrations and doses with the recommended ranges. For the comparison of doses and serum concentration-to-dose (C:D) ratios with the control group only 1 sample from each patient was used. A total of 459 analyses of 27 different drugs in samples from 8 women and 73 men were included. The median number of therapeutic drug monitoring analyses per patient was 4 (range 1-29). Thirty-seven of the 81 patients (46%) used 2 or more antipsychotics at the same time. Clozapine, lamotrigine, olanzapine, quetiapine, ziprasidone, and zuclopenthixol were often given in doses above the recommended. The serum levels were frequently above those recommended for clozapine, olanzapine, quetiapine, risperidone, ziprasidone, and zuclopenthixol. The serum levels were significantly higher in the study group than in the control group for clozapine, lamotrigine, quetiapine, and zuclopenthixol. The given dose was significantly higher in the study group than in the control group for clozapine, lamotrigine and zuclopenthixol. The C:D ratio was significantly lower in the study group than in the control group for olanzapine but higher for quetiapine. The non-evidence based practice of high-dose polypharmacy with several antipsychotics is widely used in this unit. The use of higher doses in the study group than in the control group was not due to differences in metabolism or adherence to treatment between the 2 groups. The frequent use of therapeutic drug monitoring did not seem to have a great impact on the prescribed doses.
Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N
2017-01-01
AIM To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. METHODS Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. RESULTS Out of 439 citations, 4 trials fulfilled our inclusion criteria (n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). CONCLUSION In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population. PMID:28932092
Restellini, Sophie; Kherad, Omar; Bessissow, Talat; Ménard, Charles; Martel, Myriam; Taheri Tanjani, Maryam; Lakatos, Peter L; Barkun, Alan N
2017-08-28
To performed a systematic review and meta-analysis to determine any possible differences in terms of effectiveness, safety and tolerability between existing colon-cleansing products in patients with inflammatory bowel disease. Systematic searches were performed (January 1980-September 2016) using MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials assessing preparations with or without adjuvants, given in split and non-split dosing, and in high (> 3 L) or low-volume (2 L or less) regimens. Bowel cleansing quality was the primary outcome. Secondary outcomes included patient willingness-to-repeat the procedure and side effects/complications. Out of 439 citations, 4 trials fulfilled our inclusion criteria ( n = 449 patients). One trial assessed the impact of adding simethicone to polyethylene glycol (PEG) 4 L with no effect on bowel cleansing quality, but a better tolerance. Another trial compared senna to castor oil, again without any differences in term of bowel cleansing. Two trials compared the efficacy of PEG high-volume vs PEG low-volume associated to an adjuvant in split-dose regimens: PEG low-dose efficacy was not different to PEG high-dose; OR = 0.84 (0.37-1.92). A higher proportion of patients were willing to repeat low-volume preparations vs high-volume; OR = 5.11 (1.31-20.0). In inflammatory bowel disease population, PEG low-volume regimen seems not inferior to PEG high-volume to clean the colon, and yields improved willingness-to-repeat. Further additional research is urgently required to compare contemporary products in this population.
Folic acid supplementation before and during pregnancy in the Newborn Epigenetics STudy (NEST).
Hoyo, Cathrine; Murtha, Amy P; Schildkraut, Joellen M; Forman, Michele R; Calingaert, Brian; Demark-Wahnefried, Wendy; Kurtzberg, Joanne; Jirtle, Randy L; Murphy, Susan K
2011-01-21
Folic acid (FA) added to foods during fortification is 70-85% bioavailable compared to 50% of folate occurring naturally in foods. Thus, if FA supplements also are taken during pregnancy, both mother and fetus can be exposed to FA exceeding the Institute of Medicine's recommended tolerable upper limit (TUL) of 1,000 micrograms per day (μg/d) for adult pregnant women. The primary objective is to estimate the proportion of women taking folic acid (FA) doses exceeding the TUL before and during pregnancy, and to identify correlates of high FA use. During 2005-2008, pre-pregnancy and pregnancy-related data on dietary supplementation were obtained by interviewing 539 pregnant women enrolled at two obstetrics-care facilities in Durham County, North Carolina. Before pregnancy, 51% of women reported FA supplementation and 66% reported this supplementation during pregnancy. Before pregnancy, 11.9% (95% CI = 9.2%-14.6%) of women reported supplementation with FA doses above the TUL of 1,000 μg/day, and a similar proportion reported this intake prenatally. Before pregnancy, Caucasian women were more likely to take FA doses above the TUL (OR = 2.99; 95% = 1.28-7.00), compared to African American women, while women with chronic conditions were less likely to take FA doses above the TUL (OR = 0.48; 95%CI = 0.21-0.97). Compared to African American women, Caucasian women were also more likely to report FA intake in doses exceeding the TUL during pregnancy (OR = 5.09; 95%CI = 2.07-12.49). Fifty-one percent of women reported some FA intake before and 66% during pregnancy, respectively, and more than one in ten women took FA supplements in doses that exceeded the TUL. Caucasian women were more likely to report high FA intake. A study is ongoing to identify possible genetic and non-genotoxic effects of these high doses.
Folic acid supplementation before and during pregnancy in the Newborn Epigenetics STudy (NEST)
2011-01-01
Background Folic acid (FA) added to foods during fortification is 70-85% bioavailable compared to 50% of folate occurring naturally in foods. Thus, if FA supplements also are taken during pregnancy, both mother and fetus can be exposed to FA exceeding the Institute of Medicine's recommended tolerable upper limit (TUL) of 1,000 micrograms per day (μg/d) for adult pregnant women. The primary objective is to estimate the proportion of women taking folic acid (FA) doses exceeding the TUL before and during pregnancy, and to identify correlates of high FA use. Methods During 2005-2008, pre-pregnancy and pregnancy-related data on dietary supplementation were obtained by interviewing 539 pregnant women enrolled at two obstetrics-care facilities in Durham County, North Carolina. Results Before pregnancy, 51% of women reported FA supplementation and 66% reported this supplementation during pregnancy. Before pregnancy, 11.9% (95% CI = 9.2%-14.6%) of women reported supplementation with FA doses above the TUL of 1,000 μg/day, and a similar proportion reported this intake prenatally. Before pregnancy, Caucasian women were more likely to take FA doses above the TUL (OR = 2.99; 95% = 1.28-7.00), compared to African American women, while women with chronic conditions were less likely to take FA doses above the TUL (OR = 0.48; 95%CI = 0.21-0.97). Compared to African American women, Caucasian women were also more likely to report FA intake in doses exceeding the TUL during pregnancy (OR = 5.09; 95%CI = 2.07-12.49). Conclusions Fifty-one percent of women reported some FA intake before and 66% during pregnancy, respectively, and more than one in ten women took FA supplements in doses that exceeded the TUL. Caucasian women were more likely to report high FA intake. A study is ongoing to identify possible genetic and non-genotoxic effects of these high doses. PMID:21255390
Jangjoo, Ali; Sadeghi, Ramin; Mousavi, Zohreh; Mohebbi, Masoud; Khaje, Mahtab; Asadi, Mehdi
2017-01-01
Surgery remains the most effective treatment for primary hyperparathyroidism (PHPT). Minimally invasive radioguided parathyroidectomy (MIRP) is a common technique for detecting and excising abnormal parathyroid glands. The aim of this study was to compare injections of low-dose and high-dose (99m) Tc methoxy isobutyl isonitrile (MIBI) for intraoperative localisation of parathyroid adenomas by means of a gamma probe in patients with primary hyperparathyroidism (PHPT). Thirty patients with PHPT and a preoperative diagnosis of parathyroid adenoma were enrolled between 2010 and 2012. They were considered as Group B and underwent MIRP using 5 mCi Tc-99m MIBI, and their perioperative data were compared with twenty patients treated with conventional 20 mCi Tc-99m MIBI previously (Group A). Group A was made up of 20 patients (mean age, 41.55 years; 14 women and 6 men), and group B included 30 patients (mean age, 40.43 years; 19 women and 11 men). The mean serum parathyroid hormone (PTH) and calcium values were recorded pre- and postoperatively. The mean follow-up period for the patients in the two groups was 18.4 and 16.5 months, respectively. Pre-operative evaluation demonstrated that the groups were statistically similar. Intraoperative data and success rate of surgery showed no difference between the two groups. No significant complication was detected after surgeries and no recurrence happened in either of the two groups during the follow-up period. A new protocol of MIRP using low doses of Tc-99m-MIBI resulted in an excellent success rate. Comparing results of the study, we conclude that low-dose Tc-99m-MIBI may be preferred for identification of parathyroid adenomas intraoperatively by means of a gamma probe in PHPT patients because it appears to be as effective as high-dose Tc-99m-MIBI.
NASA Astrophysics Data System (ADS)
Montanari, Davide; Scolari, Enrica; Silvestri, Chiara; Jiang Graves, Yan; Yan, Hao; Cervino, Laura; Rice, Roger; Jiang, Steve B.; Jia, Xun
2014-03-01
Cone beam CT (CBCT) has been widely used for patient setup in image-guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are (1) to commission a graphics processing unit (GPU)-based Monte Carlo (MC) dose calculation package gCTD for Varian On-Board Imaging (OBI) system and test the calculation accuracy, and (2) to quantitatively evaluate CBCT dose from the OBI system in typical IGRT scan protocols. We first conducted dose measurements in a water phantom. X-ray source model parameters used in gCTD are obtained through a commissioning process. gCTD accuracy is demonstrated by comparing calculations with measurements in water and in CTDI phantoms. Twenty-five brain cancer patients are used to study dose in a standard-dose head protocol, and 25 prostate cancer patients are used to study dose in pelvis protocol and pelvis spotlight protocol. Mean dose to each organ is calculated. Mean dose to 2% voxels that have the highest dose is also computed to quantify the maximum dose. It is found that the mean dose value to an organ varies largely among patients. Moreover, dose distribution is highly non-homogeneous inside an organ. The maximum dose is found to be 1-3 times higher than the mean dose depending on the organ, and is up to eight times higher for the entire body due to the very high dose region in bony structures. High computational efficiency has also been observed in our studies, such that MC dose calculation time is less than 5 min for a typical case.
Restored low-dose digital breast tomosynthesis: a perception study
NASA Astrophysics Data System (ADS)
Borges, Lucas R.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.
2018-03-01
This work investigates the perception of noise from restored low-dose digital breast tomosynthesis (DBT) images. First, low-dose DBT projections were generated using a dose reduction simulation algorithm. A dataset of clinical images from the Hospital of the University of Pennsylvania was used for this purpose. Low-dose projections were then denoised with a denoising pipeline developed specifically for DBT images. Denoised and noisy projections were combined to generate images with signal-to-noise ratio comparable to the full-dose images. The quality of restored low-dose and full-dose projections were first compared in terms of an objective no-reference image quality metric previously validated for mammography. In the second analysis, regions of interest (ROIs) were selected from reconstructed full-dose and restored low-dose slices, and were displayed side-by-side on a high-resolution medical display. Five medical physics specialists were asked to choose the image containing less noise and less blur using a 2-AFC experiment. The objective metric shows that, after the proposed image restoration framework was applied, images with as little as 60% of the AEC dose yielded similar quality indices when compared to images acquired with the full-dose. In the 2-AFC experiments results showed that when the denoising framework was used, 30% reduction in dose was possible without any perceived difference in noise or blur. Note that this study evaluated the observers perception to noise and blur and does not claim that the dose of DBT examinations can be reduced with no harm to the detection of cancer. Future work is necessary to make any claims regarding detection, localization and characterization of lesions.
Moliterno, David J
2011-06-01
In the absence of high-dose thienopyridines, placebo-controlled trials have demonstrated a reduction in ischemic events with intravenous glycoprotein IIb/IIIa antagonists during percutaneous coronary intervention (PCI). One head-to-head trial comparing abciximab and tirofiban among PCI patients found tirofiban to be inferior, and laboratory evidence confirmed that the bolus dose of tirofiban tested in that trial to be less effective than abciximab. Whether a higher bolus dose of tirofiban would be as efficacious as abciximab during PCI is uncertain. Patients undergoing PCI were randomized equally to abciximab or to tirofiban, given as high-dose bolus (25 μg/kg) plus 12-hr infusion (0.15 μg/kg/min). All patients received aspirin and clopidogrel and were additionally randomized to unfractionated heparin or bivalirudin. Approximately 8,000 patients were to be studied, but after 383 were enrolled, the study sponsor discontinued the trial for financial reasons. The primary endpoint of 30-day death, myocardial infarction, or urgent target vessel revascularization occurred in 8.8% of patients randomized to abciximab and 6.9% of those randomized to tirofiban. The respective rates of major bleeding were 1.5 and 1.6%. Additionally, the primary endpoint occurred in 8.1% of patients randomized to unfractionated heparin and 7.6% of those randomized to bivalirudin. The respective rates of major bleeding were 2.5% and 0.5%. With limited assessment, this direct comparison of high-dose bolus tirofiban versus abciximab produced encouraging results and suggests that further study of this tirofiban dose regimen is warranted. The limited assessments comparing heparin and bivalirudin are consistent with prior observations. Copyright © 2010 Wiley-Liss, Inc.
Kohli, Payal; Udell, Jacob A; Murphy, Sabina A; Cannon, Christopher P; Antman, Elliott M; Braunwald, Eugene; Wiviott, Stephen D
2014-01-28
The goal of this study was to determine whether there is a relationship between aspirin dose and the potent antiplatelet agent prasugrel in the TRITON-TIMI 38 (Trial to Assess Improvement in Therapeutic Outcomes by Optimizing Platelet Inhibition With Prasugrel-Thrombolysis In Myocardial Infarction 38) study. Optimal aspirin dosing after acute coronary syndromes remains uncertain. Previous studies have raised questions regarding an interaction between high-dose aspirin and the potent antiplatelet agent ticagrelor. In TRITON-TIMI 38, we classified 12,674 patients into low-dose (<150 mg) or high-dose (≥150 mg) aspirin groups based on discharge dose. We identified independent correlates of dose selection and studied the impact of aspirin dose on the clinical effects of prasugrel. There was significant geographical variation in aspirin dosing, with North American patients receiving high-dose aspirin more frequently than other countries (66% vs. 28%; p < 0.001). Clinical factors correlating with high-dose aspirin included previous percutaneous coronary intervention and use of aspirin before randomization. Characteristics associated with the use of low-dose aspirin included age ≥75 years, white race, and use of bivalirudin or a glycoprotein IIb/IIIa inhibitor during coronary intervention. Regardless of low- or high-dose aspirin use, prasugrel had lower rates of the primary efficacy endpoint (cardiovascular death, myocardial infarction, or stroke [CVD/MI/stroke]) (hazard ratio [HR]CVD/MI/stroke = 0.78 [95% confidence interval (CI) 0.64 to 0.95] and HRCVD/MI/stroke = 0.87 [95% CI 0.69 to 1.10], respectively; p value for interaction = 0.48) and higher rates of the primary safety endpoint (HR TIMI major bleeding = 1.40 [95% CI 0.81 to 2.42] and TIMImajor bleeding = 1.30 [95% CI 0.63 to 2.68], respectively; p value for interaction = 0.84) compared with clopidogrel. In TRITON-TIMI 38, the safety and efficacy outcomes of prasugrel compared with those of clopidogrel were directionally consistent regardless of aspirin dose, although only the primary efficacy endpoint achieved statistical significance. There was no clinically meaningful interaction of aspirin with prasugrel, suggesting that previous observations with potent antiplatelet agents indicating differential results are not universal. (A Comparison of Prasugrel [CS-747] and Clopidogrel in Acute Coronary Syndrome Subjects Who Are to Undergo Percutaneous Coronary Intervention; NCT00097591). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Acoustic alterations of ultrasonic vocalization in rat pups induced by perinatal hypothyroidism.
Wada, Hiromi
2017-03-01
Perinatal hypothyroidism causes serious damage to auditory functions that are essential for vocalization development. In rat pups, perinatal hypothyroidism potentially affects the development of ultrasonic vocalization (USV) as a result of hearing deficits. This study examined the effect of perinatal hypothyroidism on the development of USVs in rat pups. Twelve pregnant rats were divided into three groups and treated with the anti-thyroid drug methimazole (MMI) via drinking water, from gestational day 15 to postnatal day (PND) 21. The MMI concentration (w/v) was 0% (control group), 0.01% (low-dose group), or 0.015% (high-dose group). After birth, the pups were individually separated from the dam and littermates on PNDs 5, 10, 15, and 20, and their USVs were recorded for 5min. On PNDs 5 and 10, compared with the control group, the low- and high-dose groups exhibited reductions of both frequency-modulated and downward USVs. On PND 15, however, the low- and high-dose groups displayed increases in number, duration, and amplitude of USVs compared with those in the control group. Lower body weights were observed for the low- and high-dose groups than for the control group. Total thyroxine concentrations in plasma were dose-dependently reduced. The onset of auditory functions appeared on PNDs 11-14. Thus, the rat pups were unable to hear externally produced USVs before PND 11. USVs emitted on PNDs 5 and 10 might have been spontaneous and independent of the pups' own or littermate-emitted USVs. The developmental retardation of vocalization-related organs or muscles might underlie the acoustic alterations of USVs on PNDs 5 and 10. The greater number, duration, and amplitude of USVs on PND 15, after which the hearing onset occurred, suggested that the elevation of auditory thresholds occurred as a result of hearing deficits in the low- and high-dose groups. Perinatal hypothyroidism appears to have caused acoustic alterations in the USV development. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Bailing; Hou, Qian; Hu, Feng; Zhang, Fan
2016-07-01
Objective To investigate the mechanism behind the treatment of Alzheimer's disease (AD) with total flavones derived from Lagotis brevituba maxim (TF-LBM). Methods Fifty SAMP8 mice (aged 8 months) were randomly divided into 5 groups, (150, 300, 600) mg/kg TF-LBM groups, 0.65 g/kg donepezil HCl group and AD model group; 10 SAMR1 mice (aged 8 months) were used as a control group of normal aging. The AD model group and the normal aging control group were given the same volume of distilled water as TF-LBM groups. Eight weeks after intragastric administration, Morris water maze experiment was conducted to calculate the latency of place navigation. After the behavioral experiment, the brain cortical tissue and hippocampus (CA1 region) of the mice from various groups were taken to observe the morphological changes of the cortical tissue and hippocampus and test IL-1β, IL-6, TNF-α content. Results Compared with the model group, the escape latency of the normal aging group, the high-dose TF-LBM group and the donepezil HCl group were evidently shortened; compared with the normal aging group, IL-1β, IL-6, TNF-αof the model group increased significantly; compared with the model group, IL-1β content of the low-dose TF-LBM group had no obvious difference, while IL-1β content of the median-dose and high-dose TF-LBM groups and the donepezil HCl group decreased significantly; IL-6 content decreased in all TF-LBM groups and the donepezil HCl group; TNF-α level in the low-dose and median-dose TF-LBM groups had no evident difference, while it was reduced significantly in the high-dose TF-LBM group and the donepezil HCl group. Compared with the normal aging group, IL-1β, IL-6 and TNF-α content of the model group increased significantly; compared with the model group, IL-1β, IL-6 and TNF-α content of all TF-LBM groups and the donepezil HCl group decreased. Conclusion TF-LBM can improve the behavior change of SAMP8 mice with AD. TF-LBM can reduce the content of IL-6, IL-1β and TNF-α in cerebral cortex and hippocampus CA1.
NASA Astrophysics Data System (ADS)
Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew
2013-10-01
A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.
Palmer, Antony L; Lee, Chris; Ratcliffe, Ailsa J; Bradley, David; Nisbet, Andrew
2013-10-07
A novel phantom is presented for 'full system' dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tilton, Susan C.; Markillie, Lye Meng; Hays, Spencer
Our goal here was to identify dose and temporal dependent radiation responses in a complex tissue, reconstituted human skin. Direct sequencing of RNA (RNA-seq) was used to quantify altered transcripts following exposure to 0.1, 2 and 10 Gy of ionizing radiation at 3 and 8 hours. These doses include a low dose in the range of some medical diagnostic procedures (0.1 Gy), a dose typically received during radiotherapy (2.0 Gy) and a lethal dose (10 Gy). These doses could be received after an intentional or accidental radiation exposure and biomarkers are needed to rapidly and accurately triage exposed individuals. Amore » total of 1701 genes were deemed to be significantly affected by high dose radiation exposure with the majority of genes affected at 10 Gy. A group of 29 genes including GDF15, BBC3, PPM1D, FDXR, GADD45A, MDM2, CDKN1A, TP53INP1, CYCSP27, SESN1, SESN2, PCNA, and AEN were similarly altered at both 2 and 10 Gy, but not 0.1 Gy, at multiple time points. A much larger group of up regulated genes, including those involved in inflammatory responses, was significantly altered only after a 10 Gy exposure. At high doses, down regulated genes were associated with cell cycle regulation and exhibited an apparent linear response between 2 and 10 Gy. While only a handful of genes were significantly affected by 0.1 Gy exposure using stringent statistical filters, groups of related genes regulating cell cycle progression and inflammatory responses consistently exhibited opposite trends in their regulation compared to the high dose exposures. Differential regulation of PLK1 signaling at low and high doses was confirmed using qRT-PCR. These results indicate that some alterations in gene expression are qualitatively different at low and high doses of radiation in this model system.« less
Jhaveri, Pavan M; Teh, Bin S; Paulino, Arnold C; Smiedala, Mindy J; Fahy, Bridget; Grant, Walter; McGary, John; Butler, E Brian
2009-10-01
Combined modality treatment (neoadjuvant chemoradiotherapy followed by surgery) for locally advanced rectal cancer requires special attention to various organs at risk (OAR). As a result, the use of conformal dose delivery methods has become more common in this disease setting. Helical tomotherapy is an image-guided intensity modulated delivery system that delivers dose in a fan-beam manner at 7 degree intervals around the patient and can potentially limit normal tissue from high dose radiation while adequately treating targets. In this study we dosimetrically compare helical tomotherapy to 3D-CRT for stage T3 rectal cancer. The helical tomotherapy plans were optimized in the TomoPlan system to achieve an equivalent uniform dose of 45 Gy for 10 patients with T3N0M0 disease that was at least 5cm from the anal verge. The GTV included the rectal thickening and mass evident on colonoscopy and CT scan as well as with the help of a colorectal surgeon. The CTV included the internal iliac, obturator, and pre-sacral lymphatic chains. The OAR that were outlined included the small bowel, pelvic bone marrow, femoral heads, and bladder. Anatom-e system was used to assist in delineating GTV, CTV and OAR. These 10 plans were then duplicated and optimized into 3-field 3D-CRT plans within the Pinnacle planning system.The V[45], V[40], V[30], V[20], V[10], and mean dose to the OAR were compared between the helical tomotherapy and 3D-CRT plans. Statistically significant differences were achieved in the doses to all OAR, including all volumes and means except for V[10] for the small bowel and the femoral heads. Adequate dosimetric coverage of targets were achieved with both helical tomotherapy and 3D-CRT. Helical tomotherapy reduces the volume of normal tissue receiving high-dose RT when compared to 3D-CRT treatment. Both modalities adequately dose the tumor. Clinical studies addressing the dosimetric benefits are on-going.
NASA Astrophysics Data System (ADS)
Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Fornace, Albert J.; Datta, Kamal
2017-05-01
Ionizing radiation (IR) is a recognized risk factor for colorectal cancer (CRC) and astronauts undertaking long duration space missions are expected to receive IR doses in excess of permissible limits with implications for colorectal carcinogenesis. Exposure to IR in outer space occurs at low doses and dose rates, and energetic heavy ions due to their high linear energy transfer (high-LET) characteristics remain a major concern for CRC risk in astronauts. Previously, we have demonstrated that intestinal tumorigenesis in a mouse model (APC1638N/+) of human colorectal cancer was significantly higher after exposure to high dose rate energetic heavy ions relative to low-LET γ radiation. The purpose of the current study was to compare intestinal tumorigenesis in APC1638N/+ mice after exposure to energetic heavy ions at high (50 cGy/min) and relatively low (0.33 cGy/min) dose rate. Male and female mice (6-8 weeks old) were exposed to either 10 or 50 cGy of 28Si (energy: 300 MeV/n; LET: 70 keV/μm) or 56Fe (energy: 1000 MeV/n; LET: 148 keV/μm) ions at NASA Space Radiation Laboratory in Brookhaven National Laboratory. Mice (n = 20 mice/group) were euthanized and intestinal and colon tumor frequency and size were counted 150 days after radiation exposure. Intestinal tumorigenesis in male mice exposed to 56Fe was similar for high and low dose rate exposures. Although male mice showed a decreasing trend at low dose rate relative to high dose rate exposures, the differences in tumor frequency between the two types of exposures were not statistically significant after 28Si radiation. In female mice, intestinal tumor frequency was similar for both radiation type and dose rates tested. In both male and female mice intestinal tumor size was not different after high and low dose rate radiation exposures. Colon tumor frequency in male and female mice after high and low dose rate energetic heavy ions was also not significantly different. In conclusion, intestinal and colonic tumor frequency and size was similar irrespective of energetic heavy ion radiation dose rate suggesting that carcinogenic potential of energetic heavy ions is independent of dose rate.
Loveman, E; Cooper, K; Bryant, J; Colquitt, J L; Frampton, G K; Clegg, A
2012-01-01
The present report was commissioned as a supplement to an existing technology assessment report produced by the Peninsula Technology Assessment Group (PenTAG), which evaluated the clinical effectiveness and cost-effectiveness of dasatinib and nilotinib in patients who are either resistant or intolerant to standard-dose imatinib. This report evaluates the clinical effectiveness and cost-effectiveness of dasatinib, nilotinib and high-dose imatinib within their licensed indications for the treatment of people with chronic myeloid leukaemia (CML) who are resistant to standard-dose imatinib. Bibliographic databases were searched from inception to January 2011, including The Cochrane Library, MEDLINE (Ovid), EMBASE (Ovid), and MEDLINE In-Process & Other Non-Indexed Citations. Bibliographies of related papers were screened, key conferences were searched, and experts were contacted to identify additional published and unpublished references. This report includes systematic reviews of clinical effectiveness and cost-effectiveness studies, an independent appraisal of information submitted by drug manufacturers to the National Institute for Health and Clinical Excellence (NICE), an independent appraisal of the PenTAG economic evaluation, and new economic analyses adapting the PenTAG economic model. Standard systematic procedures involving two reviewers to maintain impartiality and transparency, and to minimise bias, were conducted. Eleven studies met the inclusion criteria. Four of these studies included new data published since the PenTAG report; all of these were in chronic-phase CML. No relevant studies on the clinical effectiveness of nilotinib were found. The clinical effectiveness studies on dasatinib [one arm of a randomised controlled trial (RCT)] and high-dose imatinib (one arm of a RCT and three single-arm cohort studies) had major methodological limitations. These limitations precluded a comparison of the different arms within the RCT. Data from the studies are summarised in this report, but caution in interpretation is required. One economic evaluation was identified that compared dasatinib with high-dose imatinib in patients with chronic-phase CML who were CML resistant to standard-dose imatinib. Two industry submissions and the PenTAG economic evaluation were critiqued and differences in the assumptions and results were identified. The PenTAG economic model was adapted and new analyses conducted for the interventions dasatinib, nilotinib and high-dose imatinib and the comparators interferon alfa, standard-dose imatinib, stem cell transplantation and hydroxycarbamide. The results suggest that the three interventions, dasatinib, nilotinib and high-dose imatinib, have similar costs and cost-effectiveness compared with hydroxycarbamide, with a cost-effectiveness of around £30,000 per quality-adjusted life-year gained. However, it is not possible to derive firm conclusions about the relative cost-effectiveness of the three interventions owing to great uncertainty around data inputs. Uncertainty was explored using deterministic sensitivity analyses, threshold analyses and probabilistic sensitivity analyses. The paucity of good-quality evidence should be considered when interpreting this report. This review has identified very limited new information on clinical effectiveness of the interventions over that already shown in the PenTAG report. Limitations in the data exist; however, the results of single-arm studies suggest that the interventions can lead to improvements in haematological and cytogenetic responses in people with imatinib-resistant CML. The economic analyses do not highlight any one of the interventions as being the most cost-effective; however, the analysis results are highly uncertain owing to lack of agreement on appropriate assumptions. Recommendations for future research made by PenTAG, for a good-quality RCT comparing the three treatments remain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yaparpalvi, R; Mynampati, D; Kuo, H
Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performedmore » using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm may very well be warranted.« less
1991-09-01
2 2. Dosimetry ............................................. 4 C. OVERVIEW OF EXPERIMENT............................... 5 11. ELECTRON BEAM...From these measurements, the dose was calculated and then compared to a measured dose obtained from TLD dosimetry . Technical 5 problems with the...LINAC precluded TLD dosimetry from being accomplished during the first run and, therefore, was performed on the second run only. After irradiation, a NaI
NASA Astrophysics Data System (ADS)
Surdo, A. I.; Milman, I. I.; Abashev, R. M.; Vlasov, M. I.
2014-12-01
Results of studies of the thermoluminescence (TL) of anion-deficient alumina (α-Al2O3 - δ) single crystals and based on them TLD-500 detectors exposed to pulsed X-ray and electron radiation in a wide range of doses D, pulsed dose rates P p , and temperatures are described. The TL responses of α-Al2O3 - δ for continuous and pulsed X-ray irradiation at D = 0.05-150 Gy are compared. Unlike continuous irradiation, in the case of pulsed irradiation at P p ≥ 6 × 106 Gy/s, a linear increase in the TL response as a function of D is registered in the main and "chromium" peaks at 450 and 580 K, respectively, with a decrease in the slope of the dose dependence at D > 2 Gy for the peak at 450 K. It is found that high-dose irradiation (>60 Gy) leads to the formation of a new TL peak at 830 K and the preferential redistribution of the stored light sums into this peak. The dose dependence for the TL peak at 830 K is studied. It is established that it is linear in a super-high dose range of 104 to 6 × 106 Gy at P p = 2.6 × 1011 Gy/s.
Huang, Qijie; Jabbour, Salma K; Xiao, Zhiyan; Yue, Ning; Wang, Xiao; Cao, Hongbin; Kuang, Yu; Zhang, Yin; Nie, Ke
2018-04-25
The principle aim of this study is to incorporate 4DCT ventilation imaging into functional treatment planning that preserves high-functioning lung with both double scattering and scanning beam techniques in proton therapy. Eight patients with locally advanced non-small-cell lung cancer were included in this study. Deformable image registration was performed for each patient on their planning 4DCTs and the resultant displacement vector field with Jacobian analysis was used to identify the high-, medium- and low-functional lung regions. Five plans were designed for each patient: a regular photon IMRT vs. anatomic proton plans without consideration of functional ventilation information using double scattering proton therapy (DSPT) and intensity modulated proton therapy (IMPT) vs. functional proton plans with avoidance of high-functional lung using both DSPT and IMPT. Dosimetric parameters were compared in terms of tumor coverage, plan heterogeneity, and avoidance of normal tissues. Our results showed that both DSPT and IMPT plans gave superior dose advantage to photon IMRTs in sparing low dose regions of the total lung in terms of V5 (volume receiving 5Gy). The functional DSPT only showed marginal benefit in sparing high-functioning lung in terms of V5 or V20 (volume receiving 20Gy) compared to anatomical plans. Yet, the functional planning in IMPT delivery, can further reduce the low dose in high-functioning lung without degrading the PTV dosimetric coverages, compared to anatomical proton planning. Although the doses to some critical organs might increase during functional planning, the necessary constraints were all met. Incorporating 4DCT ventilation imaging into functional proton therapy is feasible. The functional proton plans, in intensity modulated proton delivery, are effective to further preserve high-functioning lung regions without degrading the PTV coverage.
A medical image-based graphical platform -- features, applications and relevance for brachytherapy.
Fonseca, Gabriel P; Reniers, Brigitte; Landry, Guillaume; White, Shane; Bellezzo, Murillo; Antunes, Paula C G; de Sales, Camila P; Welteman, Eduardo; Yoriyaz, Hélio; Verhaegen, Frank
2014-01-01
Brachytherapy dose calculation is commonly performed using the Task Group-No 43 Report-Updated protocol (TG-43U1) formalism. Recently, a more accurate approach has been proposed that can handle tissue composition, tissue density, body shape, applicator geometry, and dose reporting either in media or water. Some model-based dose calculation algorithms are based on Monte Carlo (MC) simulations. This work presents a software platform capable of processing medical images and treatment plans, and preparing the required input data for MC simulations. The A Medical Image-based Graphical platfOrm-Brachytherapy module (AMIGOBrachy) is a user interface, coupled to the MCNP6 MC code, for absorbed dose calculations. The AMIGOBrachy was first validated in water for a high-dose-rate (192)Ir source. Next, dose distributions were validated in uniform phantoms consisting of different materials. Finally, dose distributions were obtained in patient geometries. Results were compared against a treatment planning system including a linear Boltzmann transport equation (LBTE) solver capable of handling nonwater heterogeneities. The TG-43U1 source parameters are in good agreement with literature with more than 90% of anisotropy values within 1%. No significant dependence on the tissue composition was observed comparing MC results against an LBTE solver. Clinical cases showed differences up to 25%, when comparing MC results against TG-43U1. About 92% of the voxels exhibited dose differences lower than 2% when comparing MC results against an LBTE solver. The AMIGOBrachy can improve the accuracy of the TG-43U1 dose calculation by using a more accurate MC dose calculation algorithm. The AMIGOBrachy can be incorporated in clinical practice via a user-friendly graphical interface. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
The dose-effect relationship of baclofen in alcohol dependence: A 1-year cohort study.
Pignon, Baptiste; Labreuche, Julien; Auffret, Marine; Gautier, Sophie; Deheul, Sylvie; Simioni, Nicolas; Cottencin, Olivier; Bordet, Régis; Duhamel, Alain; Rolland, Benjamin
2017-07-01
Our aim is to study the relationship between dose of baclofen and effectiveness in alcohol dependence. Two hundred two patients with alcohol dependence, who received baclofen treatment for drinking reduction, were followed up for 1 year. For each patient-month of treatment, the maximum daily dose of baclofen (DDB) and average weekly alcohol consumption (AWAC) were calculated. We defined a favorable drinking outcome as an AWAC under 200 g/w for at least 2 consecutive months. We divided the DDB of each patient-month into 3 categories (low dose: <90 mg/d, medium dose: 90-150 mg/d, and high dose: >150 mg/d) and investigated the relationship between reaching a favorable outcome and the concurrent DDB category in a time-varying Cox regression analysis. Hazard ratios (HRs) were adjusted based on age, sex, and initial AWAC. One hundred forty subjects were followed during at least 1 month. Of these patients, 58 (41%) had a favorable drinking outcome. In comparison to low dose, medium dose was associated with a decreased rate of favorable drinking outcome (HR = 0.42; 95% CI [0.20, 0.88]), whereas no difference was found with high dose (HR = 1.31; 95% CI [0.65, 2.64]). The relationship between dose of baclofen and favorable drinking outcome was U-shaped, that is, was increased at low and high doses compared to medium doses. Copyright © 2017 John Wiley & Sons, Ltd.
[LDL cholesterol lowering therapy: no target value but personalised treatment].
Simoons, Maarten L; Deckers, Jaap W
2015-01-01
We previously recommended that LDL cholesterol lowering therapy be based on the risk for (recurrent) coronary events, rather than on arbitrary targets for serum LDL cholesterol concentration. We also recommended refraining from therapy with ezetimibe until its efficacy in preventing cardiovascular events had been documented. At the American Heart Association scientific sessions 2014 the results of the IMPROVE-IT study were reported. In this large, randomised trial, a modest benefit of the combination of simvastatin plus ezetimibe over simvastatin alone was reported after 7 years of treatment. The efficacy of such combination therapy was similar to the efficacy of high-dose statin therapy, while the combination therapy is much more expensive. Comparing the efficacy and costs of different preventive therapies, we recommend first prescribing aspirin and a moderate dose of statin, secondly an ACE inhibitor. A high-dose statin should be considered in high-risk patients. The combination of simvastatin and ezetimibe should be prescribed only in high-risk patients (e.g. diabetics after myocardial infarction) who do not tolerate high-dose statins.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rouabhi, O; Gross, B; Xia, J
2015-06-15
Purpose: To evaluate the dosimetric and temporal effects of high dose rate treatment mode for respiratory-gated radiation therapy in lung cancer patients. Methods: Treatment plans from five lung cancer patients (3 nongated (Group 1), 2 gated at 80EX-80IN (Group 2)) were retrospectively evaluated. The maximum tumor motions range from 6–12 mm. Using the same planning criteria, four new treatment plans, corresponding to four gating windows (20EX–20IN, 40EX–40IN, 60EX–60IN, and 80EX–80IN), were generated for each patient. Mean tumor dose (MTD), mean lung dose (MLD), and lung V20 were used to assess the dosimetric effects. A MATLAB algorithm was developed to computemore » treatment time by considering gantry rotation time, time to position collimator leaves, dose delivery time (scaled relative to the gating window), and communication overhead. Treatment delivery time for each plan was estimated using a 500 MU/min dose rate for the original plans and a 1500 MU/min dose rate for the gated plans. Results: Differences in MTD were less than 1Gy across plans for all five patients. MLD and lung V20 were on average reduced between −16.1% to −6.0% and −20.0% to −7.2%, respectively for non-gated plans when compared with the corresponding gated plans, and between − 5.8% to −4.2% and −7.0% to −5.4%, respectively for plans originally gated at 80EX–80IN when compared with the corresponding 20EX-20IN to 60EX– 60IN gated plans. Treatment delivery times of gated plans using high dose rate were reduced on average between −19.7% (−1.9min) to −27.2% (−2.7min) for originally non-gated plans and −15.6% (−0.9min) to −20.3% (−1.2min) for originally 80EX-80IN gated plans. Conclusion: Respiratory-gated radiation therapy in lung cancer patients can reduce lung toxicity, while maintaining tumor dose. Using a gated high-dose-rate treatment, delivery time comparable to non-gated normal-dose-rate treatment can be achieved. This research is supported by Siemens Medical Solutions USA, Inc.« less
NASA Astrophysics Data System (ADS)
Ren, Jiyun; Menon, Geetha; Sloboda, Ron
2013-04-01
Although the Manchester system is still extensively used to prescribe dose in brachytherapy (BT) for locally advanced cervix cancer, many radiation oncology centers are transitioning to 3D image-guided BT, owing to the excellent anatomy definition offered by modern imaging modalities. As automatic dose optimization is highly desirable for 3D image-based BT, this study comparatively evaluates the performance of two optimization methods used in BT treatment planning—Nelder-Mead simplex (NMS) and simulated annealing (SA)—for a cervix BT computer simulation model incorporating a Manchester-style applicator. Eight model cases were constructed based on anatomical structure data (for high risk-clinical target volume (HR-CTV), bladder, rectum and sigmoid) obtained from measurements on fused MR-CT images for BT patients. D90 and V100 for HR-CTV, D2cc for organs at risk (OARs), dose to point A, conformation index and the sum of dwell times within the tandem and ovoids were calculated for optimized treatment plans designed to treat the HR-CTV in a highly conformal manner. Compared to the NMS algorithm, SA was found to be superior as it could perform optimization starting from a range of initial dwell times, while the performance of NMS was strongly dependent on their initial choice. SA-optimized plans also exhibited lower D2cc to OARs, especially the bladder and sigmoid, and reduced tandem dwell times. For cases with smaller HR-CTV having good separation from adjoining OARs, multiple SA-optimized solutions were found which differed markedly from each other and were associated with different choices for initial dwell times. Finally and importantly, the SA method yielded plans with lower dwell time variability compared with the NMS method.
NASA Astrophysics Data System (ADS)
De Saint-Hubert, Marijke; Verellen, Dirk; Poels, Kenneth; Crijns, Wouter; Magliona, Federica; Depuydt, Tom; Vanhavere, Filip; Struelens, Lara
2017-07-01
Medulloblastoma treatment involves irradiation of the entire central nervous system, i.e. craniospinal irradiation (CSI). This is associated with the significant exposure of large volumes of healthy tissue and there is growing concern regarding treatment-associated side effects. The current study compares out-of-field organ doses in children receiving CSI through 3D-conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT), helical tomotherapy (HT) and an electron-based technique, and includes radiation doses resulting from imaging performed during treatment. An extensive phantom study is performed, using an anthropomorphic phantom corresponding to a five year old child, in which organ absorbed doses are measured using thermoluminescent detectors. Additionally, the study evaluates and explores tools for calculating out-of-field patient doses using the treatment planning system (TPS) and analytical models. In our study, 3D-CRT resulted in very high doses to a limited number of organs, while it was able to spare organs such as the lungs and breast when compared to IMRT and HT. Both IMRT and HT spread the dose over more organs and were able to spare the heart, thyroid, bladder, uterus and testes when compared to 3D-CRT. The electron-based technique considerably decreased the out-of-field doses in deep-seated organs but could not avoid nearby out-of-field organs such as the lungs, ribs, adrenals, kidneys and uterus. The daily imaging dose is small compared to the treatment dose burden. The TPS error for out-of-field doses was most pronounced for organs further away from the target; nevertheless, no systematic underestimation was observed for any of the studied TPS systems. Finally, analytical modeling was most optimal for 3D-CRT although the number of organs that could be modeled was limited. To conclude, none of the techniques studied was capable of sparing all organs from out-of-field doses. Nevertheless, the electron-based technique showed the most promise for out-of-field organ dose reduction during CSI when compared to photon techniques.
Oparaji, U; Tsai, Y H; Liu, Y C; Lee, K W; Patelli, E; Sheu, R J
2017-06-01
This paper presents improved and extended results of our previous study on corrections for conventional neutron dose meters used in environments with high-energy neutrons (En > 10 MeV). Conventional moderated-type neutron dose meters tend to underestimate the dose contribution of high-energy neutrons because of the opposite trends of dose conversion coefficients and detection efficiencies as the neutron energy increases. A practical correction scheme was proposed based on analysis of hundreds of neutron spectra in the IAEA-TRS-403 report. By comparing 252Cf-calibrated dose responses with reference values derived from fluence-to-dose conversion coefficients, this study provides recommendations for neutron field characterization and the corresponding dose correction factors. Further sensitivity studies confirm the appropriateness of the proposed scheme and indicate that (1) the spectral correction factors are nearly independent of the selection of three commonly used calibration sources: 252Cf, 241Am-Be and 239Pu-Be; (2) the derived correction factors for Bonner spheres of various sizes (6"-9") are similar in trend and (3) practical high-energy neutron indexes based on measurements can be established to facilitate the application of these correction factors in workplaces. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nowik, P; Bujila, R; Merzan, D
2015-06-15
Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CTmore » dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.« less
Pilkinton, Mark A; Nicholas, Katherine J; Warren, Christian M; Smith, Rita M; Yoder, Sandra M; Talbot, H Keipp; Kalams, Spyros A
2017-01-05
Influenza related morbidity and mortality disproportionately impacts older adults. The serologic response to vaccine is diminished in older adults; however, high dose inactivated influenza vaccine (HD IIV) has shown improved rates of seroconversion compared to standard dose (SD IIV). We hypothesize this may be due to the superior ability of high dose vaccine to activate T follicular helper (Tfh) cells and provide B cell dependent T cell help. We measured peripheral Tfh (pTfh) activation in 50 community dwelling adults 65years or older who were randomly assigned to receive either the HD IIV or SD IIV. The HD vaccination elicited significantly higher levels of ICOS expression on pTfh cells, at day 7 compared to SD vaccination (p=0.02). The magnitude of the increase in ICOS+ pTfh cells from baseline to day 7 was predictive of seroconversion for both influenza A and B vaccination. Strong Tfh activation in response to influenza vaccination forecasts successful seroconversion in older adults, and HD IIV elicits greater Tfh activation than SD IIV. Future vaccine studies should focus on ways to further optimize the Tfh response. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of Individual Radiosensitivity to γ-Rays and Carbon Ions.
Shim, Grace; Normil, Marie Delna; Testard, Isabelle; Hempel, William M; Ricoul, Michelle; Sabatier, Laure
2016-01-01
Carbon ions are an up-and-coming ion species, currently being used in charged particle radiotherapy. As it is well established that there are considerable interindividual differences in radiosensitivity in the general population that can significantly influence clinical outcomes of radiotherapy, we evaluate the degree of these differences in the context of carbon ion therapy compared with conventional radiotherapy. In this study, we evaluate individual radiosensitivity following exposure to carbon-13 ions or γ-rays in peripheral blood lymphocytes of healthy individuals based on the frequency of ionizing radiation (IR)-induced DNA double strand breaks (DSBs) that was either misrepaired or left unrepaired to form chromosomal aberrations (CAs) (simply referred to here as DSBs for brevity). Levels of DSBs were estimated from the scoring of CAs visualized with telomere/centromere-fluorescence in situ hybridization (TC-FISH). We examine radiosensitivity at the dose of 2 Gy, a routinely administered dose during fractionated radiotherapy, and we determined that a wide range of DSBs were induced by the given dose among healthy individuals, with highly radiosensitive individuals harboring more IR-induced breaks in the genome than radioresistant individuals following exposure to the same dose. Furthermore, we determined the relative effectiveness of carbon irradiation in comparison to γ-irradiation in the induction of DSBs at each studied dose (isodose effect), a quality we term "relative dose effect" (RDE). This ratio is advantageous, as it allows for simple comparison of dose-response curves. At 2 Gy, carbon irradiation was three times more effective in inducing DSBs compared with γ-irradiation (RDE of 3); these results were confirmed using a second cytogenetic technique, multicolor-FISH. We also analyze radiosensitivity at other doses (0.2-15 Gy), to represent hypo- and hyperfractionation doses and determined that RDE is dose dependent: high ratios at low doses, and approaching 1 at high doses. These results could have clinical implications as IR-induced DNA damage and the ensuing CAs and genomic instability can have significant cellular consequences that could potentially have profound implications for long-term human health after IR exposure, such as the emergence of secondary cancers and other pathobiological conditions after radiotherapy.
Smith, Lynette M; Gallagher, J Christopher; Suiter, Corinna
2017-10-01
Falls are a serious health problem in the aging population. Because low levels of vitamin D have been associated with increased fall rates, many trials have been performed with vitamin D; two meta-analyses showed either a small effect or no effect of vitamin D on falls. We conducted a study of the effect of vitamin D on serum 25 hydroxyvitamin D (25OHD) and data on falls was collected as a secondary outcome. In a 12-month double blind randomized placebo trial, elderly women, mean age 66 years, were randomized to one of seven daily oral doses of vitamin D or placebo. The main inclusion criterion for study was a baseline serum 25OHD<20ng/ml (50nmol/L). A history of falls was collected at baseline and fall events were collected every 3 months. Results showed that the effect of vitamin D on falls followed a U-shaped curve whether analyzed by dose or serum 25OHD levels. There was no decrease in falls on low vitamin D doses 400, 800 IU, a significant decrease on medium doses 1600, 2400,3200 IU (p=0.020) and no decrease on high doses 4000, 4800 IU compared to placebo (p=0.55). When compared to 12-month serum 25OHD quintiles, the faller rate was 60% in the lowest quintile <25ng/ml (<50nmol/L), 21% in the low middle quintile 32-38ng/ml (80-95nmo/L), 72% in the high middle quintile 38-46ng/ml (95-115nmo/L) and 45% in the highest quintile 46-66ng/ml (115-165nmol/L). In the subgroup with a fall history, fall rates were 68% on low dose, 27% on medium doses and 100% on higher doses. Fall rates on high doses were increased compared to medium doses (Odds Ratio 5.6.95% CI: 2.1-14.8). In summary, the maximum decrease in falls corresponds to a 12- month serum 25OHD of 32-38ng/ml (80-95nmol/L) and faller rates increase as serum 25OHD exceed 40-45ng/ml (100-112.5nmol/L). The Tolerable upper limit (TUL) recently increased in 2010 from 2000 to 4000 IU/day may need to be reduced in elderly women especially in those with a fall history. Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel acenocoumarol pharmacogenomic dosing algorithm for the Greek population of EU-PACT trial.
Ragia, Georgia; Kolovou, Vana; Kolovou, Genovefa; Konstantinides, Stavros; Maltezos, Efstratios; Tavridou, Anna; Tziakas, Dimitrios; Maitland-van der Zee, Anke H; Manolopoulos, Vangelis G
2017-01-01
To generate and validate a pharmacogenomic-guided (PG) dosing algorithm for acenocoumarol in the Greek population. To compare its performance with other PG algorithms developed for the Greek population. A total of 140 Greek patients participants of the EU-PACT trial for acenocoumarol, a randomized clinical trial that prospectively compared the effect of a PG dosing algorithm with a clinical dosing algorithm on the percentage of time within INR therapeutic range, who reached acenocoumarol stable dose were included in the study. CYP2C9 and VKORC1 genotypes, age and weight affected acenocoumarol dose and predicted 53.9% of its variability. EU-PACT PG algorithm overestimated acenocoumarol dose across all different CYP2C9/VKORC1 functional phenotype bins (predicted dose vs stable dose in normal responders 2.31 vs 2.00 mg/day, p = 0.028, in sensitive responders 1.72 vs 1.50 mg/day, p = 0.003, in highly sensitive responders 1.39 vs 1.00 mg/day, p = 0.029). The PG algorithm previously developed for the Greek population overestimated the dose in normal responders (2.51 vs 2.00 mg/day, p < 0.001). Ethnic-specific dosing algorithm is suggested for better prediction of acenocoumarol dosage requirements in patients of Greek origin.
Effect of Qing Nao tablet on blood stasis model of mice
NASA Astrophysics Data System (ADS)
Kong, Xuejun; Hao, Shaojun; Wang, Hongyu; Liu, Xiaobin; Xie, Guoqi; Li, Wenjun; Zhang, Zhengchen
2018-04-01
To investigate the effect of Qing Nao tablet on mouse model of blood stasis syndrome, 60 mice, male and female, were randomly divided into 6 groups, were fed with large, small doses of Qing Nao tablet suspension, Naoluotong saline suspension and the same volume (group 2, 0.1ml/10g), administer 1 times daily, orally for 15 days. Intragastric administration for first days, in addition to the 1 group saline group every day in the hind leg intramuscular saline, the other 5 groups each rat day hind leg muscle injection of dexamethasone 0.8mg/kg intramuscular injection every day, 1 times, 15 days. 1 hour continuous intramuscular injection and intramuscular drug perfusion on the sixteenth day after mice. The eyeball blood, heparin after whole blood viscosity test. Compared with the control group, model group, high and low shear viscosity were significantly increased (P<0.01), indicating that the model was successful. Compared with the model group, high dose group and Qing Nao tablet Naoluotong group can significantly reduce the viscosity at high shear and (P<0.01), middle dose Qing Nao tablet group can significantly reduce high shear and shear viscosity (P<0.05); large, middle dose Qing Nao tablet group can significantly reduce the low shear viscosity (P<0.05), Naoluotong group can significantly reduce the low shear viscosity (P<0.01); low dose Qing Nao tablet group were lower high cut, low shear viscosity and trend The potential (P>0.05). The Qing Nao tablet has a good effect on the model of blood stasis in mice.
Dose of Prophylactic Platelet Transfusions and Prevention of Hemorrhage
Slichter, Sherrill J.; Kaufman, Richard M.; Assmann, Susan F.; McCullough, Jeffrey; Triulzi, Darrell J.; Strauss, Ronald G.; Gernsheimer, Terry B.; Ness, Paul M.; Brecher, Mark E.; Josephson, Cassandra D.; Konkle, Barbara A.; Woodson, Robert D.; Ortel, Thomas L.; Hillyer, Christopher D.; Skerrett, Donna L.; McCrae, Keith R.; Sloan, Steven R.; Uhl, Lynne; George, James N.; Aquino, Victor M.; Manno, Catherine S.; McFarland, Janice G.; Hess, John R.; Leissinger, Cindy; Granger, Suzanne
2010-01-01
BACKGROUND We conducted a trial of prophylactic platelet transfusions to evaluate the effect of platelet dose on bleeding in patients with hypoproliferative thrombocytopenia. METHODS We randomly assigned hospitalized patients undergoing hematopoietic stem-cell transplantation or chemotherapy for hematologic cancers or solid tumors to receive prophylactic platelet transfusions at a low dose, a medium dose, or a high dose (1.1×1011, 2.2×1011, or 4.4×1011 platelets per square meter of body-surface area, respectively), when morning platelet counts were 10,000 per cubic millimeter or lower. Clinical signs of bleeding were assessed daily. The primary end point was bleeding of grade 2 or higher (as defined on the basis of World Health Organization criteria). RESULTS In the 1272 patients who received at least one platelet transfusion, the primary end point was observed in 71%, 69%, and 70% of the patients in the low-dose group, the medium-dose group, and the high-dose group, respectively (differences were not significant). The incidences of higher grades of bleeding, and other adverse events, were similar among the three groups. The median number of platelets transfused was significantly lower in the low-dose group (9.25×1011) than in the medium-dose group (11.25×1011) or the high-dose group (19.63×1011) (P = 0.002 for low vs. medium, P<0.001 for high vs. low and high vs. medium), but the median number of platelet transfusions given was significantly higher in the low-dose group (five, vs. three in the medium-dose and three in the high-dose group; P<0.001 for low vs. medium and low vs. high). Bleeding occurred on 25% of the study days on which morning platelet counts were 5000 per cubic millimeter or lower, as compared with 17% of study days on which platelet counts were 6000 to 80,000 per cubic millimeter (P<0.001). CONCLUSIONS Low doses of platelets administered as a prophylactic transfusion led to a decreased number of platelets transfused per patient but an increased number of transfusions given. At doses between 1.1×1011 and 4.4×1011 platelets per square meter, the number of platelets in the prophylactic transfusion had no effect on the incidence of bleeding. (ClinicalTrials.gov number, NCT00128713.) PMID:20164484
Dose Accuracy and Injection Force of Different Insulin Glargine Pens
Friedrichs, Arnd; Bohnet, Janine; Korger, Volker; Adler, Steffen; Schubert-Zsilavecz, Manfred; Abdel-Tawab, Mona
2013-01-01
Background Dose accuracy and injection force, representing key parameters of insulin pens, were determined for three pens delivering insulin glargine-based copies, Pen Royale (WR) and DispoPen (WD) for Glaritus® (Wockhardt) and GanLee Pen (GL) for Basalin® (Gan & Lee), compared with pens of the originator, ClikSTAR® (CS) and S o l o S TA R® (SS) for Lantus® (Sanofi) . Methods Using the weighing procedure recommended by DIN EN ISO 11608–1:2000, dose accuracy was evaluated based on nonrandomized delivery of low (5 U), mid (30 U), and high (60 U) dosage levels. Injection force was measured by dispensing the maximum dose of insulin (60 U for the GL, WR, and WD; 80 U for the SS and CS) at dose speeds of 6 and 10 U/s. Results All tested pens delivered comparable average doses within the DIN EN ISO 11608–1:2000 limits at all dosage levels. The GL revealed a higher coefficient of variation (CV) at 5 U, and the WR and WD had higher CVs at all dosage levels compared with the CS and SS. Injection force was higher for the WR, WD, and GL compared with the CS and SS at both dose speeds. In contrast to the CS and SS with an end-of-content feature, doses exceeding the remaining insulin could be dialed with the WR, GL, and WD and, apparently, dispensed with the WD. Conclusions All pens fulfilled the dose accuracy requirements defined by DIN EN ISO 11608–1:2000 standards at all three dosage levels, with the WR, WD, and GL showing higher dosage variability and injection force compared with the SS and CS. Thus, the devices that deliver insulin glargine copies show different performance characteristics compared with the originator. J Diabetes Sci Technol 2013;7(5):1346–1353 PMID:24124963
Landes, Reid D.; Lensing, Shelly Y.; Kodell, Ralph L.; Hauer-Jensen, Martin
2014-01-01
The dose of a substance that causes death in P% of a population is called an LDP, where LD stands for lethal dose. In radiation research, a common LDP of interest is the radiation dose that kills 50% of the population by a specified time, i.e., lethal dose 50 or LD50. When comparing LD50 between two populations, relative potency is the parameter of interest. In radiation research, this is commonly known as the dose reduction factor (DRF). Unfortunately, statistical inference on dose reduction factor is seldom reported. We illustrate how to calculate confidence intervals for dose reduction factor, which may then be used for statistical inference. Further, most dose reduction factor experiments use hundreds, rather than tens of animals. Through better dosing strategies and the use of a recently available sample size formula, we also show how animal numbers may be reduced while maintaining high statistical power. The illustrations center on realistic examples comparing LD50 values between a radiation countermeasure group and a radiation-only control. We also provide easy-to-use spreadsheets for sample size calculations and confidence interval calculations, as well as SAS® and R code for the latter. PMID:24164553
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova-Carter, Magdalena; Qu, Bradley; Palma, Bianey
2015-05-15
Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphicalmore » user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.« less
2017-07-10
Tubular Breast Cancer Stage II; Tubular Breast Cancer Stage III; Mucinous Breast Cancer Stage II; Breast Cancer Female NOS; Invasive Ductal Breast Cancer; HER2 Positive Breast Cancer; Inflammatory Breast Cancer
SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Y
Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. Themore » margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.« less
Kim, Ji Young; Park, Ju Yeon; Kang, Hee Jung; Kim, Oh Yoen; Lee, Jong Ho
2012-07-17
The reported health benefits of Korean red ginseng (KRG) include antioxidant, antitumor, antimutagenic, and immunomodulatory activities; however, the effects on oxidative stress have not yet been evaluated. Therefore, we assessed the effect of KRG on antioxidant enzymes and oxidative stress markers in humans. We conducted a randomized, double-blind, placebo-controlled study with three groups, including placebo, low-dose (3 g/day), and high-dose (6 g/day), which were randomly assigned to healthy subjects aged 20-65 years. Lymphocyte DNA damage, antioxidative enzyme activity, and lipid peroxidation were assessed before and after the 8-week supplementation. Fifty-seven subjects completed the protocol. Plasma superoxide dismutase (SOD) activity after the 8-week KRG supplementation was significantly higher in the low-and high-dose groups compared to baseline. Plasma glutathione peroxidase (GPx) and catalase activities were also increased after the high-dose supplementation. Furthermore, the DNA tail length and tail moment were significantly reduced after the supplementation (low-dose and high-dose), and plasma oxidized low-density lipoprotein (LDL) levels were reduced in low-dose and high-dose groups, but increased in the placebo group. The net changes in oxidized LDL after the supplementation differed significantly between both KRG supplementation groups and the placebo group. Net changes in GPx, SOD and catalase activities, and DNA tail length and tail moment were significantly different between the high-dose group and the placebo group. Additionally, the net changes in urinary 8-epi-PGF(2α) were significantly different between the KRG supplementation groups and the placebo group. KRG supplementation may attenuate lymphocyte DNA damage and LDL oxidation by upregulating antioxidant enzyme activity.
2012-01-01
Background The reported health benefits of Korean red ginseng (KRG) include antioxidant, antitumor, antimutagenic, and immunomodulatory activities; however, the effects on oxidative stress have not yet been evaluated. Therefore, we assessed the effect of KRG on antioxidant enzymes and oxidative stress markers in humans. Methods We conducted a randomized, double-blind, placebo-controlled study with three groups, including placebo, low-dose (3 g/day), and high-dose (6 g/day), which were randomly assigned to healthy subjects aged 20–65 years. Lymphocyte DNA damage, antioxidative enzyme activity, and lipid peroxidation were assessed before and after the 8-week supplementation. Results Fifty-seven subjects completed the protocol. Plasma superoxide dismutase (SOD) activity after the 8-week KRG supplementation was significantly higher in the low-and high-dose groups compared to baseline. Plasma glutathione peroxidase (GPx) and catalase activities were also increased after the high-dose supplementation. Furthermore, the DNA tail length and tail moment were significantly reduced after the supplementation (low-dose and high-dose), and plasma oxidized low-density lipoprotein (LDL) levels were reduced in low-dose and high-dose groups, but increased in the placebo group. The net changes in oxidized LDL after the supplementation differed significantly between both KRG supplementation groups and the placebo group. Net changes in GPx, SOD and catalase activities, and DNA tail length and tail moment were significantly different between the high-dose group and the placebo group. Additionally, the net changes in urinary 8-epi-PGF2α were significantly different between the KRG supplementation groups and the placebo group. Conclusions KRG supplementation may attenuate lymphocyte DNA damage and LDL oxidation by upregulating antioxidant enzyme activity. PMID:22805313
Rioja, Eva; Rubio-Martínez, Luis M.; Monteith, Gabrielle; Kerr, Carolyn L.
2013-01-01
The objectives of this study were to determine the analgesic and motor effects of a high-volume intercoccygeal epidural injection of bupivacaine at 2 concentrations in cows. A prospective, randomized, blinded, crossover trial was conducted on 6 adult cows. An indwelling epidural catheter was placed in the first intercoccygeal space and advanced 10 cm cranially. All the cows received 3 treatments with a washout period of 48 h: saline (control), 0.125% bupivacaine (high dose), or 0.0625% bupivacaine (low dose), at a final volume of 0.15 mL per kilogram of body weight, infused manually into the epidural space over a period of 15 min. The anal and tail tone and motor deficits of the pelvic limbs were evaluated in 5 of the cows with use of a numerical rating scale and a visual analogue scale (VAS). Sensory block was assessed in 4 of the cows by the response to needle pricks in different regions with the use of a VAS. Measurements were obtained before and at different time points after injection, up to 360 min. Analysis of variance for repeated measures and post-hoc Tukey’s and Dunnett’s tests were used. Differences were considered significant when the P-value was ≤ 0.05. One cow became recumbent 6 h after injection. Anal and tail tones were significantly decreased and motor deficits of the pelvic limbs were significantly increased after bupivacaine treatment compared with control treatment. The overall mean VASpain scores ± standard deviation were 66 ± 8 after control treatment, 52 ± 5 after low-dose bupivacaine treatment, and 43 ± 5 after high-dose bupivacaine treatment. The pain scores were significantly lower in caudal regions up to the saphenous nerve after high-dose bupivacaine treatment compared with control treatment and significantly lower in the anus, vulva, and tail after low-dose bupivacaine treatment compared with control treatment. Thus, analgesia with moderate motor deficits of the pelvic limbs may be obtained with 0.125% bupivacaine administered epidurally. PMID:24124269
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, C; Lee, P; Jiang, S
2015-06-15
Purpose: To compare dosimetric data of patients treated for early-stage larynx cancer on Cyberknife and Linac IMRT. Methods: Nine patients were treated with Cyberknife to a dose of 45 Gy in 10 fractions of the involved hemilarynx. The prescription dose provided at least 95% of PTV coverage. After Cyberknife treatment, the CT images and contours were sent to Pinnacle treatment planning system for IMRT planning on a regular SBRT linac with same dose prescription and constrains. Dose to target and normal tissue, including the arytenoids, cord, carotid arteries, thyroid, and skin, were analyzed using dose volume histograms. Results: For Cyberknifemore » plan, the conformity indices are within 1.11–1.33. The average dose to the contralateral arytenoids for Cyberknife plans was 28.9±6.5Gy), which is lower than the same mean dose for IMRT plans (34.0±5.2 Gy). The average maximum dose to the ipsilateral and contralateral carotid artery were 20.6 ±9.1 Gy and 10.2±6.0 Gy respectively for Cybeknife comparing with 22.1±8.0 Gy and 12.0±5.1 Gy for IMRT. The mean dose to the thyroid was 3.6±2.2 Gy for Cyberknife and 3.4±2.4 Gy for IMRT. As shown in DVH, the Cyberknife can deliver less dose to the normal tissue which is close to target area comparing with IMRT Plans. However, IMRT plan’s can give more sparing for the critical organs which is far away from the target area. Conclusion: We have compared the dosimetric parameters of Cyberknife and linac IMRT plans for patients with early-stage larynx cancer. Both Cyberknife and IMRT plans can achieve conformal dose distribution to the target area. Cyberknife was able to reduce normal tissue dose in high doses region while IMRT plans can reduce the dose of the normal tissue at the low dose region. These dosimetric parameters can be used to guide future prospective protocols using SBRT for larynx cancer.« less
Effects of chromium picolinate on oxidative damage in primary piglet hepatocytes.
Tan, Gao-Yi; Bi, Jin-Ming; Zhang, Min-Hong; Feng, Jing-Hai; Xie, Peng; Zheng, Shan-Shan
2008-12-01
Chromium picolinate is a popular nutritional supplement whose safety has been questioned because of the potential risk of oxidative DNA damage. To investigate this possibility, a dose-dependent study was performed in piglet hepatocyte cultures in which low (8 microM), medium (200 microM), and high (400 microM) doses of chromium picolinate were tested and compared to untreated controls. After 48 h incubation, there were no significant differences in the levels of intracellular reactive oxygen species, medium lactate dehydrogenase activity, and comet indicators between the three experimental groups and controls (p > 0.05). In the 8 microM-treated group, the intracellular malondialdehyde content was significantly decreased relative to controls (p < 0.05). All of the studied parameters showed a dose-dependent increase that was statistically significant between the low and high doses (p < 0.05). These results suggest that: (1) chromium picolinate may affect the oxidative status of piglet hepatocytes; (2) the appropriate dose (approximately physiological concentration) of chromium picolinate can inhibit lipid peroxidation, and (3) high doses of chromium picolinate have no significant effects on oxidative damage in piglet hepatocytes, but the existing evidence also imply that exposure to a higher dose appears to be unwarranted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moirano, J
Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference pointmore » air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.« less
Gapeev, A B; Lushnikov, K V; Shumilina, Iu V; Chemeris, N K
2006-01-01
The anti-inflammatory effect of low-intensity extremely high-frequency electromagnetic radiation (EHF EMR, 42.0 GHz, 0.1 mW/cm2) was compared with the action of the known anti-inflammatory drug sodium diclofenac and the antihistamine clemastine on acute inflammatory reaction in NMRI mice. The local inflammatory reaction was induced by intraplantar injection of zymosan into the left hind paw. Sodium diclofenac in doses of 2, 3, 5, 10, and 20 mg/kg or clemastine in doses of 0.02, 0.1, 0.2, 0.4, and 0.6 mg/kg were injected intraperitoneally 30 min after the initiation of inflammation. The animals were whole-body exposed to EHF EMR for 20 min at 1 h after the initiation of inflammation. The inflammatory reaction was assessed over 3 - 8 h after the initiation by measuring the footpad edema and hyperthermia of the inflamed paw. Sodium diclofenac in doses of 5 - 20 mg/kg reduced the exudative edema on the average by 26% as compared to the control. Hyperthermia of the inflamed paw decreased to 60% as the dose of was increased diclofenac up to 20 mg/kg. EHF EMR reduced both the footpad edema and hyperthermia by about 20%, which was comparable with the effect of a single therapeutic dose of diclofenac (3 - 5 mg/kg). The combined action of diclofenac and the exposure to the EHF EMR caused a partial additive effect. Clemastine in doses of 0.02-0.4 mg/kg it did not cause any significant effects on the exudative edema, but in a dose of 0.6 mg/kg it reduced edema by 14 - 22% by 5 - 8 h after zymosan injection. Clemastine caused a dose-dependent increase in hyperthermia of inflamed paw at doses of 0.02-0.2 mg/kg and did not affect the hyperthermia at doses of 0.4 and 0.6 mg/kg. The combined action of clemastine and EHF EMR exposure caused a dose-dependent abolishment of the anti-inflammatory effect of EHF EMR. The results obtained suggest that both arachidonic acid metabolites and histamine are involved in the realization of anti-inflammatory effects of low-intensity
Jeong, Jae Yoon; Sohn, Joo Hyun; Baek, Yang Hyun; Cho, Yong Kyun; Kim, Yongsoo; Kim, Hyeonjin
2017-08-28
To evaluate the efficacy and safety of HL tablet extracted from magnolia officinalis for treating patients with nonalcoholic fatty liver disease (NAFLD). Seventy-four patients with NAFLD diagnosed by ultrasonography were randomly assigned to 3 groups given high dose (400 mg) HL tablet, low dose (133.4 mg) HL tablet and placebo, respectively, daily for 12 wk. The primary endpoint was post-treatment change of hepatic fat content (HFC) measured by magnetic resonance spectroscopy. Secondary endpoints included changes of serum aspartate aminotransferase, alanine aminotransferase (ALT), cholesterol, triglyceride, free fatty acid, homeostasis model assessment-estimated insulin resistance, and body mass index (BMI). The mean HFC of the high dose HL group, but not of the low dose group, declined significantly after 12 wk of treatment (high dose vs placebo, P = 0.033; low dose vs placebo, P = 0.386). The mean changes of HFC from baseline at week 12 were -1.7% ± 3.1% in the high dose group ( P = 0.018), -1.21% ± 4.97% in the low dose group ( P = 0.254) and 0.61% ± 3.87% in the placebo group (relative changes compared to baseline, high dose were: -12.1% ± 23.5%, low dose: -3.2% ± 32.0%, and placebo: 7.6% ± 44.0%). Serum ALT levels also tended to decrease in the groups receiving HL tablet while other factors were unaffected. There were no moderate or severe treatment-related safety issues during the study. HL tablet is effective in reducing HFC without any negative lipid profiles, BMI changes and adverse effects.
Jeong, Jae Yoon; Sohn, Joo Hyun; Baek, Yang Hyun; Cho, Yong Kyun; Kim, Yongsoo; Kim, Hyeonjin
2017-01-01
AIM To evaluate the efficacy and safety of HL tablet extracted from magnolia officinalis for treating patients with nonalcoholic fatty liver disease (NAFLD). METHODS Seventy-four patients with NAFLD diagnosed by ultrasonography were randomly assigned to 3 groups given high dose (400 mg) HL tablet, low dose (133.4 mg) HL tablet and placebo, respectively, daily for 12 wk. The primary endpoint was post-treatment change of hepatic fat content (HFC) measured by magnetic resonance spectroscopy. Secondary endpoints included changes of serum aspartate aminotransferase, alanine aminotransferase (ALT), cholesterol, triglyceride, free fatty acid, homeostasis model assessment-estimated insulin resistance, and body mass index (BMI). RESULTS The mean HFC of the high dose HL group, but not of the low dose group, declined significantly after 12 wk of treatment (high dose vs placebo, P = 0.033; low dose vs placebo, P = 0.386). The mean changes of HFC from baseline at week 12 were -1.7% ± 3.1% in the high dose group (P = 0.018), -1.21% ± 4.97% in the low dose group (P = 0.254) and 0.61% ± 3.87% in the placebo group (relative changes compared to baseline, high dose were: -12.1% ± 23.5%, low dose: -3.2% ± 32.0%, and placebo: 7.6% ± 44.0%). Serum ALT levels also tended to decrease in the groups receiving HL tablet while other factors were unaffected. There were no moderate or severe treatment-related safety issues during the study. CONCLUSION HL tablet is effective in reducing HFC without any negative lipid profiles, BMI changes and adverse effects. PMID:28932090
Chronic prazosin attenuates the natriuretic response to a modest saline load in anaesthetized rats.
Penner, S. B.; Smyth, D. D.
1988-01-01
1. The effect of chronic prazosin pretreatment (3 days) on the ability to excrete a modest saline load (i.v. saline, 0.097 ml min-1) was studied in the anaesthetized rat. Three days before the experiment, the drinking water was replaced with 0.5% dextrose (control), 0.015 mg ml-1 prazosin in 0.5% dextrose (low dose) or 0.15 mg ml-1 prazosin in 0.5% dextrose (high dose). 2. The selectivity of the prazosin for alpha 1-adrenoceptors was evaluated in pithed rats. The pressor response to phenylephrine was partially attenuated by the low dose of prazosin and completely attenuated by the high dose of prazosin. The pressor response to clonidine was slightly decreased by the 3 day prazosin pretreatment indicating a selectivity for alpha 1-adrenoceptors. 3. In rats pretreated with the low dose of prazosin, there was a significant decrease in sodium and water, but not potassium excretion as compared to the control group. Captopril failed to alter these effects of the low dose of prazosin. Blood pressure and creatinine clearance were the same in both groups. In rats pretreated with the high dose of prazosin, there was a further decrease in sodium and water but not potassium excretion. However, this dose of prazosin also significantly decreased blood pressure and increased creatinine clearance. A decrease in renal perfusion pressure with an aortic clamp to the same level as that observed with the high prazosin dose also decreased sodium and water but not potassium excretion. The decrease in sodium and water excretion was not as great as that observed with the high dose of prazosin.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2896036
Wennberg, Berit M; Baumann, Pia; Gagliardi, Giovanna; Nyman, Jan; Drugge, Ninni; Hoyer, Morten; Traberg, Anders; Nilsson, Kristina; Morhed, Elisabeth; Ekberg, Lars; Wittgren, Lena; Lund, Jo-Åsmund; Levin, Nina; Sederholm, Christer; Lewensohn, Rolf; Lax, Ingmar
2011-05-01
In SBRT of lung tumours no established relationship between dose-volume parameters and the incidence of lung toxicity is found. The aim of this study is to compare the LQ model and the universal survival curve (USC) to calculate biologically equivalent doses in SBRT to see if this will improve knowledge on this relationship. Toxicity data on radiation pneumonitis grade 2 or more (RP2+) from 57 patients were used, 10.5% were diagnosed with RP2+. The lung DVHs were corrected for fractionation (LQ and USC) and analysed with the Lyman- Kutcher-Burman (LKB) model. In the LQ-correction α/β = 3 Gy was used and the USC parameters used were: α/β = 3 Gy, D(0) = 1.0 Gy, [Formula: see text] = 10, α = 0.206 Gy(-1) and d(T) = 5.8 Gy. In order to understand the relative contribution of different dose levels to the calculated NTCP the concept of fractional NTCP was used. This might give an insight to the questions of whether "high doses to small volumes" or "low doses to large volumes" are most important for lung toxicity. NTCP analysis with the LKB-model using parameters m = 0.4, D(50) = 30 Gy resulted for the volume dependence parameter (n) with LQ correction n = 0.87 and with USC correction n = 0.71. Using parameters m = 0.3, D(50) = 20 Gy n = 0.93 with LQ correction and n = 0.83 with USC correction. In SBRT of lung tumours, NTCP modelling of lung toxicity comparing models (LQ,USC) for fractionation correction, shows that low dose contribute less and high dose more to the NTCP when using the USC-model. Comparing NTCP modelling of SBRT data and data from breast cancer, lung cancer and whole lung irradiation implies that the response of the lung is treatment specific. More data are however needed in order to have a more reliable modelling.
Schaly, B; Bauman, G S; Battista, J J; Van Dyk, J
2005-02-07
The goal of this study is to validate a deformable model using contour-driven thin-plate splines for application to radiation therapy dose mapping. Our testing includes a virtual spherical phantom as well as real computed tomography (CT) data from ten prostate cancer patients with radio-opaque markers surgically implanted into the prostate and seminal vesicles. In the spherical mathematical phantom, homologous control points generated automatically given input contour data in CT slice geometry were compared to homologous control point placement using analytical geometry as the ground truth. The dose delivered to specific voxels driven by both sets of homologous control points were compared to determine the accuracy of dose tracking via the deformable model. A 3D analytical spherically symmetric dose distribution with a dose gradient of approximately 10% per mm was used for this phantom. This test showed that the uncertainty in calculating the delivered dose to a tissue element depends on slice thickness and the variation in defining homologous landmarks, where dose agreement of 3-4% in high dose gradient regions was achieved. In the patient data, radio-opaque marker positions driven by the thin-plate spline algorithm were compared to the actual marker positions as identified in the CT scans. It is demonstrated that the deformable model is accurate (approximately 2.5 mm) to within the intra-observer contouring variability. This work shows that the algorithm is appropriate for describing changes in pelvic anatomy and for the dose mapping application with dose gradients characteristic of conformal and intensity modulated radiation therapy.
The features of radiation dose variations onboard ISS and Mir space station: comparative study.
Tverskaya, L V; Panasyuk, M I; Reizman, S Ya; Sosnovets, E N; Teltsov, M V; Tsetlin, V V
2004-01-01
The dynamics of the ISS-measured radiation dose variations since August 2000 is studied. Use is made of the data obtained with the R-16 instrument, which consists of two ionization chambers behind different shielding thicknesses. The doses recorded during solar energetic particle (SEP) events are compared with the data obtained also by R-16 on Mir space station. The SEP events in the solar maximum of the current cycle make a much smaller contribution to the radiation dose compared with the October 1989 event recorded on Mir space station. In the latter event, the proton intensity was peaking during a strong magnetic storm. The storm-time effect of solar proton geomagnetic cutoff decreases on dose variations is estimated. The dose variations on Mir space stations due to formation of a new radiation belt of high-energy protons and electrons during a sudden commencement of March 24, 1991 storm are also studied. It was for the first time throughout the ISS and Mir dose measurement period that the counting rates recorded by both R-16 channels on ISS in 2001-2002 were nearly the same during some time intervals. This effect may arise from the decreases of relativistic electron fluxes in the outer radiation belt. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
Bouchet, Audrey; Bräuer-Krisch, Elke; Prezado, Yolanda; El Atifi, Michèle; Rogalev, Léonid; Le Clec'h, Céline; Laissue, Jean Albert; Pelletier, Laurent; Le Duc, Géraldine
2016-08-01
Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident, highly focused synchrotron beam into arrays of parallel microbeams, typically a few tens of microns wide and depositing several hundred grays. This irradiation modality was shown to have a high therapeutic impact on tumors, especially in intracranial locations. However, mechanisms responsible for such a property are not fully understood. Thanks to recent progress in dosimetry, we compared the effect of MRT and synchrotron broad beam (BB) radiation therapy delivered at comparable doses (equivalent to MRT valley dose) on tumor growth control and on classical radiobiological functions by histologic evaluation and/or transcriptomic analysis. MRT significantly improved survival of rats bearing 9L intracranial glioma compared with BB radiation therapy delivered at a comparable dose (P<.001); the efficacy of MRT and BB radiation therapy was similar when the MRT dose was half that of BB. The greater efficacy of MRT was not correlated with a difference in cell proliferation (Mki67 and proliferating cell nuclear antigen) or in transcriptomic stimulation of angiogenesis (vascular endothelial growth factor A or tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 2) but was correlated with a higher cell death rate (factor for apoptosis signals) and higher recruitment of macrophages (tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 1 and CD68 transcripts) a few days after MRT. These results show the superiority of MRT over BB radiation therapy when applied at comparable doses, suggesting that spatial fractionation is responsible for a specific and particularly efficient tissue response. The higher induction of cell death and immune cell activation in brain tumors treated by MRT may be involved in such responses. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouchet, Audrey, E-mail: audrey.m.bouchet@gmail.com; Biomedical Beamline, European Synchrotron Radiation Facility, Grenoble; Bräuer-Krisch, Elke
Purpose: Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident, highly focused synchrotron beam into arrays of parallel microbeams, typically a few tens of microns wide and depositing several hundred grays. This irradiation modality was shown to have a high therapeutic impact on tumors, especially in intracranial locations. However, mechanisms responsible for such a property are not fully understood. Methods and Materials: Thanks to recent progress in dosimetry, we compared the effect of MRT and synchrotron broad beam (BB) radiation therapy delivered at comparable doses (equivalent to MRT valley dose) on tumor growth control andmore » on classical radiobiological functions by histologic evaluation and/or transcriptomic analysis. Results: MRT significantly improved survival of rats bearing 9L intracranial glioma compared with BB radiation therapy delivered at a comparable dose (P<.001); the efficacy of MRT and BB radiation therapy was similar when the MRT dose was half that of BB. The greater efficacy of MRT was not correlated with a difference in cell proliferation (Mki67 and proliferating cell nuclear antigen) or in transcriptomic stimulation of angiogenesis (vascular endothelial growth factor A or tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 2) but was correlated with a higher cell death rate (factor for apoptosis signals) and higher recruitment of macrophages (tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 1 and CD68 transcripts) a few days after MRT. Conclusions: These results show the superiority of MRT over BB radiation therapy when applied at comparable doses, suggesting that spatial fractionation is responsible for a specific and particularly efficient tissue response. The higher induction of cell death and immune cell activation in brain tumors treated by MRT may be involved in such responses.« less
Pfaar, O; Hohlfeld, J M; Al-Kadah, B; Hauswald, B; Homey, B; Hunzelmann, N; Schliemann, S; Velling, P; Worm, M; Klimek, L
2017-11-01
Subcutaneous allergen immunotherapy with grass pollen allergoids has been proven to be effective and safe in the treatment of patients with allergic rhinoconjunctivitis. Based on the extensive cross-reactivity among Pooideae species, it has been suggested that grass pollen extracts could be prepared from a single species, rather than from a multiple species mixture. To find the optimal dose of a Phleum pratense (P. pratense) allergoid preparation and compare its efficacy and safety to a 6-grass pollen allergoid preparation. In this double-blind, placebo-controlled study (EudraCT: 2011-000674-58), three doses of P. pratense allergoid (1800 therapeutic units (TU), standard-dose 6000 TU and 18 000 TU) were compared with placebo and the marketed 6-grass pollen allergoid (6000 TU). In a pre-seasonal dosing regimen, 102 patients were randomized to five treatment groups and received nine subcutaneous injections. The primary efficacy endpoint was the change in weal size (late-phase reaction [LPR]) in response to the intracutaneous testing (ICT) before and after treatment, comparing the active allergoids to placebo. Secondary outcomes were the change in Total Nasal Symptom Score (TNSS) assessed in the allergen exposure chamber (AEC), the changes in P. pratense-serum-specific IgG 4 and the incidence of adverse events (AEs). All three doses of the P. pratense and the 6-grass pollen allergoid preparations were significantly superior to placebo for the primary outcome, whereas there were no significant differences in the change in TNSS. Compared to the standard-dose, the high-dose of P. pratense did not produce any additional significant benefit, but showed a slight increase in AEs. Yet this increase in AEs was lower than for the 6-grass pollen preparation. The standard-dose of the new P. pratense allergoid was comparable to the marketed 6-grass pollen preparation at equal dose for the parameters measured. © 2017 The Authors. Clinical & Experimental Allergy Published by John Wiley & Sons Ltd.
Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W
2015-07-01
CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.
Carbon-11-cocaine binding compared at subpharmacological and pharmacological doses: A PET study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volkow, N.D.; Fowler, J.S.; Logan, J.
The authors have characterized cocaine binding in the brain to a high-affinity site on the dopamine transporter using PET and tracer doses of [{sup 11}C]cocaine in the baboon in vivo. The binding pattern, however, of cocaine at tracer (subpharmacological) doses may differ from that observed when the drug is taken in behaviorally active doses, particularly since in vitro studies have shown that cocaine also binds to low affinity binding sites. PET was used to compare and characterize [{sup 11}C]cocaine binding in the baboon brain at low subpharmacological (18 {mu}g average dose) and at pharmacological (8000 {mu}g) doses. Serial studies onmore » the same day in the same baboon were used to assess the reproducibility of repeated measures and to assess the effects of drugs which inhibit the dopamine, norepinephrine and serotonin transporters. Time-activity curves from brain and the arterial plasma input function were used to calculate the steady-state distribution volume (DV). At subpharmacological doses, [{sup 11}C]cocaine had a more homogeneous distribution. Bmax/Kd for sub-pharmacological [{sup 11}C]cocaine corresponded to 0.5-0.6 and for pharmacological [{sup 11}C]cocaine it corresponded to 0.1-0.2. Two-point Scatchard analysis gave Bmax = 2300 pmole/g and Kd = 3600 nM. Bmax/Kd for sub-pharmacological doses of [{sup 11}C]cocaine was decreased by cocaine and drugs that inhibit the dopamine transporter, to 0.1-0.2, but not by drugs that inhibit the serotonin or the norepinephrine transporter. None of these drugs changed Bmax/Kd for a pharmacological dose of [{sup 11}C]cocaine. At subpharmacological doses, [{sup 11}C]cocaine binds predominantly to a high-affinity site on the dopamine transporter. 36 refs., 4 figs., 5 tabs.« less
Xu, Hang; Su, Shi; Tang, Wuji; Wei, Meng; Wang, Tao; Wang, Dongjin; Ge, Weihong
2015-09-01
A large number of warfarin pharmacogenetics algorithms have been published. Our research was aimed to evaluate the performance of the selected pharmacogenetic algorithms in patients with surgery of heart valve replacement and heart valvuloplasty during the phase of initial and stable anticoagulation treatment. 10 pharmacogenetic algorithms were selected by searching PubMed. We compared the performance of the selected algorithms in a cohort of 193 patients during the phase of initial and stable anticoagulation therapy. Predicted dose was compared to therapeutic dose by using a predicted dose percentage that falls within 20% threshold of the actual dose (percentage within 20%) and mean absolute error (MAE). The average warfarin dose for patients was 3.05±1.23mg/day for initial treatment and 3.45±1.18mg/day for stable treatment. The percentages of the predicted dose within 20% of the therapeutic dose were 44.0±8.8% and 44.6±9.7% for the initial and stable phases, respectively. The MAEs of the selected algorithms were 0.85±0.18mg/day and 0.93±0.19mg/day, respectively. All algorithms had better performance in the ideal group than in the low dose and high dose groups. The only exception is the Wadelius et al. algorithm, which had better performance in the high dose group. The algorithms had similar performance except for the Wadelius et al. and Miao et al. algorithms, which had poor accuracy in our study cohort. The Gage et al. algorithm had better performance in both phases of initial and stable treatment. Algorithms had relatively higher accuracy in the >50years group of patients on the stable phase. Copyright © 2015 Elsevier Ltd. All rights reserved.
Morain, P; Robin, J L; De Nanteuil, G; Jochemsen, R; Heidet, V; Guez, D
2000-10-01
The aim of this study was to characterize the pharmacodynamics and the pharmacokinetics of S 17092, a new orally active prolyl endopeptidase inhibitor following single and repeated administration in elderly healthy volunteers. This was a double-blind, randomized, placebo-controlled, single and multiple dose study in elderly healthy male and female volunteers (n = 36). Four doses were investigated in sequential order: 100, 400, 800 and 1200 mg. Each dose was administered orally once a day in single administration and then, after a 1 week washout period, during 7 days. Pharmacodynamics were assessed by measurement of plasmatic prolyl endopeptidase (PEP) activity, quantitative electroencephalogram (EEG) and psychometric tests. S 17092 concentrations in plasma were quantified by high performance liquid chromatography with tandem mass spectrometric detection. PEP activity in plasma was dose-dependently inhibited both after administration of a single dose and after repeated doses of S 17092. The mean maximal inhibition was obtained within 0.5-2 h after dosing, while inhibition lasted at least 12 h after dose administration. S 17092 appeared to be a centrally active substance as it induced statistically significant modifications in EEG compared with placebo. S 17092 at 100 mg exerted an acute increase in alpha band following single administration at 4 h and 8 h postdosing. When administered repeatedly over 7 days S 17092 did not appear to induce significant lasting central nervous system (CNS) effects. In psychometric tests, response times in the numeric working memory were significantly reduced compared with placebo, following the 800 mg dose. There were some beneficial residual effects of the 1200 mg dose on day 13: delayed word recall and word recognition sensitivity improved compared with the declines noted under placebo. Maximum measured concentration (Cmax) and area under the curve (AUC) parameters increased in proportion to the dose. The terminal half-life (t(1/2)) values ranged between 9 and 31 h on day 1 and between 7 and 18 h on day 14. A high interindividual variability was observed at all dose levels. S 17092 was well tolerated with no clinically significant changes in laboratory or physical parameters observed at any dose. S 17092 had a potent, dose-dependent inhibitory effect on plasmatic PEP, increased alpha band EEG at the 100 mg dose and improved performance in two verbal memory tests at the 1200 mg dose while there were disruption to the vigilance task. The results obtained in elderly healthy subjects indicated that S 17092 is suitable for once-daily dosing without any serious adverse events.
Effects of lasalocid or monensin on legume or grain (feedlot) bloat.
Bartley, E E; Nagaraja, T G; Pressman, E S; Dayton, A D; Katz, M P; Fina, L R
1983-06-01
Doses of .66 to .99 mg monensin/kg body weight reduced legume bloat in cattle about 66% when compared with pretreatment bloat scores. Similar doses of lasalocid reduced legume bloat about 26%. A dose of 44 mg poloxalene/kg body weight (recommended dose for field use) reduced legume bloat 100%. Monensin or lasalocid combined with 25 or 50% of the recommended dose of poloxalene reduced bloat under that of the antibiotics alone, but did not achieve 100% reduction. The antibiotic thiopeptin provided no preventive effect on legume bloat. Lasalocid, monensin or an experimental polyether antibiotic (X-14,547 A) at a dose of 1.32 mg/kg body weight when tested on cattle bloated on high grain diets reduced bloat by 92, 64 and 25%, respectively. Lasalocid at .66 mg/kg effectively prevented bloat from developing when given to animals before the feeding of high grain diets; however, a 1.32-mg dose was required to control bloat in cattle that were already bloating before they were given lasalocid. A dose of 1.32 mg salinomycin was ineffective in controlling grain bloat.
2012-01-01
The objective of the study is a comparative evaluation of flavone isolated from Mucuna pruriens and coumarin isolated from Ionidium suffruticosum was assessed for the hypolipidemic activity in rats fed with high fat diet. The acute toxicity study was found that flavone (M.pruriens) and coumarin (I.suffruticosum) are safe up to 100mg/kg, so one tenth of this dose (10mg/kg) was consider as a evaluation dose. High fat diet group of rats showed significant (p<0.001) elevation in plasma total and LDL-cholesterol, triglycerides and phospholipids. Administration of flavone (M. pruriens) and coumarin isolated from (I.suffruticosum) at the dose of 10mg/kg b.wt/day along with high fat diet significantly (p<0.001) prevented the rise in the plasma total and LDL-cholesterol, triglycerides and phospholipids than that of other extracts. However, treatment of coumarin isolated from (I.suffruticosum) had showed more cardio protective effect against hyperlipidemia than that of flavone (M.pruriens). PMID:23031584
Chu, Cindy S; Bancone, Germana; Moore, Kerryn A; Win, Htun Htun; Thitipanawan, Niramon; Po, Christina; Chowwiwat, Nongnud; Raksapraidee, Rattanaporn; Wilairisak, Pornpimon; Phyo, Aung Pyae; Keereecharoen, Lily; Proux, Stéphane; Charunwatthana, Prakaykaew; Nosten, François; White, Nicholas J
2017-02-01
Radical cure of Plasmodium vivax malaria with 8-aminoquinolines (primaquine or tafenoquine) is complicated by haemolysis in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. G6PD heterozygous females, because of individual variation in the pattern of X-chromosome inactivation (Lyonisation) in erythroid cells, may have low G6PD activity in the majority of their erythrocytes, yet are usually reported as G6PD "normal" by current phenotypic screening tests. Their haemolytic risk when treated with 8-aminoquinolines has not been well characterized. In a cohort study nested within a randomised clinical trial that compared different treatment regimens for P. vivax malaria, patients with a normal standard NADPH fluorescent spot test result (≳30%-40% of normal G6PD activity) were randomised to receive 3 d of chloroquine or dihydroartemisinin-piperaquine in combination with primaquine, either the standard high dose of 0.5 mg base/kg/day for 14 d or a higher dose of 1 mg base/kg/d for 7 d. Patterns of haemolysis were compared between G6PD wild-type and G6PD heterozygous female participants. Between 21 February 2012 and 04 July 2014, 241 female participants were enrolled, of whom 34 were heterozygous for the G6PD Mahidol variant. Haemolysis was substantially greater and a larger proportion of participants reached the threshold of clinically significant haemolysis (fractional haematocrit reduction >25%) in G6PD heterozygotes taking the higher (7 d) primaquine dose (9/17 [53%]) compared with G6PD heterozygotes taking the standard high (14 d) dose (2/16 [13%]; p = 0.022). In heterozygotes, the mean fractional haematocrit reductions were correspondingly greater with the higher primaquine dose (7-d regimen): -20.4% (95% CI -26.0% to -14.8%) (nadir on day 5) compared with the standard high (14 d) dose: -13.1% (95% CI -17.6% to -8.6%) (nadir day 6). Two heterozygotes taking the higher (7 d) primaquine dose required blood transfusion. In wild-type participants, mean haematocrit reductions were clinically insignificant and similar with both doses: -5.8 (95% CI -7.2% to -4.4%) (nadir day 3) compared with -5.5% (95% CI -7.4% to -3.7%) (nadir day 4), respectively. Limitations to this nested cohort study are that the primary objective of the trial was designed to measure efficacy and not haemolysis in relation to G6PD genotype and that the heterozygote groups were small. Higher daily doses of primaquine have the potential to cause clinically significant haemolysis in G6PD heterozygous females who are reported as phenotypically normal with current point of care tests. ClinicalTrials.gov NCT01640574.
External doses of residents near Semipalatinsk nuclear test site.
Takada, J; Hoshi, M; Nagatomo, T; Yamamoto, M; Endo, S; Takatsuji, T; Yoshikawa, I; Gusev, B I; Sakerbaev, A K; Tchaijunusova, N J
1999-12-01
Accumulated external radiation doses of residents near the Semipalatinsk nuclear test site of the former USSR are presented as a results of study by the thermoluminescence technique for bricks sampled at several settlements in 1995 and 1996. The external doses that we evaluated from exposed bricks were up to about 100 cGy for resident. The external doses at several points in the center of Semipalatinsk City ranged from a background level to 60 cGy, which was remarkably high compared with the previously reported values based on military data.
Corticosteroid injection for the treatment of carpal tunnel syndrome
O'Gradaigh, D; Merry, P
2000-01-01
OBJECTIVE—To compare low and high dose, and short and long acting corticosteroids in the treatment of carpal tunnel syndrome. METHODS—A randomised, controlled, single blind trial with electromyographic and subjective outcome measures. RESULTS—25 mg hydrocortisone is as effective as higher doses or long acting triamcinolone at a six week and six month follow up. CONCLUSION—As low dose steroid is as effective, and potentially less toxic, this should be the recommended dose for injection of carpal tunnel syndrome. PMID:11053073
NASA Technical Reports Server (NTRS)
Campola, Michael; Wyrwas, Edward
2017-01-01
The purpose of this test was to characterize the Micron MT29F128G08AJAAAs parameter degradation for total dose response and to evaluate and compare lot date codes for sensitivity. In the test, the device was exposed to both low dose and high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated to determine which lot is more robust.
Li, Chunfu; Wang, Yanhua; Wu, Xuedong; Pei, Fuyu; He, Yuelin; Feng, Xiaoqin; Liu, Huaying
2012-05-01
To investigate the effects of different doses of antithymocyte globubin-fresenius (ATG-F) for allogeneic hematopoietic stem cell transplantation (allo-HSCT) in patients with beta-thalassemia Major. Sixty-four children with beta-thalassemia major undergoing allo-HSCT were divided into two equal groups to receive ATG-F pretreatments at high (30 mg/kg) or low (15 mg/kg) doses as part of the conditioning regimen including mainly cyclophosphamide, busulfan, fludarabine, and thiotepa. The outcomes of the patients were compared between the two groups. No obvious difference were noted in the time to leukocyte and platelet engraftment between the two groups. The incidence of grade II-IV acute graft-versus-host disease (aGVHD) appeared to be higher in the low-dose group than in the high-dose group (12.5% vs 9.4%). The incidence of grade III-IV aGVHD was also higher in the low dose group (12.5% vs 6.3%), but the difference was not statistically significant. Application of high-dose ATG-F was associated with a higher rate of probable and possible fungal infection (P<0.05). The two doses of ATG-F is feasible as a part of the conditioning regimen for allo-HSCT in children with beta-thalassemia major.
Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Mowlavi, Ali Asghar; Meigooni, Ali Soleimani
2012-01-01
Background Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. Materials and methods MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution, radial dose function and 2D anisotropy function of the source. These parameters of this source are compared with the available data for Ralstron 60Co and microSelectron192Ir sources. Besides, a superimposition method was developed to extend the obtained results for the GZP6 source No. 3 to other GZP6 sources. Results The simulated value for dose rate constant for GZP6 source was 1.104±0.03 cGyh-1U-1. The graphical and tabulated radial dose function and 2D anisotropy function of this source are presented here. The results of these investigations show that the dosimetric parameters of GZP6 source are comparable to those for the Ralstron source. While dose rate constant for the two 60Co sources are similar to that for the microSelectron192Ir source, there are differences between radial dose function and anisotropy functions. Radial dose function of the 192Ir source is less steep than both 60Co source models. In addition, the 60Co sources are showing more isotropic dose distribution than the 192Ir source. Conclusions The superimposition method is applicable to produce dose distributions for other source arrangements from the dose distribution of a single source. The calculated dosimetric quantities of this new source can be introduced as input data to the GZP6 treatment planning system (TPS) and to validate the performance of the TPS. PMID:23077455
Ghorbani, Mahdi; Toossi, Mohammad Taghi Bahreyni; Mowlavi, Ali Asghar; Roodi, Shahram Bayani; Meigooni, Ali Soleimani
2012-01-01
Background. The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. Materials and methods A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 60Co brachytherapy source with GafChromic® EBT radiochromic films. In these investigations, the non-uniformity of the film and scanner response, combined, as well as the films sensitivity to scanner’s light source was evaluated using multiple samples of films, prior to the source dosimetry. The results of these measurements were compared with the Monte Carlo simulated data using MCNPX code. In addition, isodose curves acquired by radiochromic films and Monte Carlo simulation were compared with those provided by the GZP6 treatment planning system. Results Scanning of samples of uniformly irradiated films demonstrated approximately 2.85% and 4.97% nonuniformity of the response, respectively in the longitudinal and transverse directions of the film. Our findings have also indicated that the film response is not affected by the exposure to the scanner’s light source, particularly in multiple scanning of film. The results of radiochromic film measurements are in good agreement with the Monte Carlo calculations (4%) and the corresponding dose values presented by the GZP6 treatment planning system (5%). Conclusions The results of these investigations indicate that the Microtek ScanMaker 1000XL color scanner in conjunction with GafChromic EBT film is a reliable system for dosimetric evaluation of a high dose rate brachytherapy source. PMID:23411947
Kolshus, E; Jelovac, A; McLoughlin, D M
2017-02-01
Brief-pulse electroconvulsive therapy (ECT) is the most acutely effective treatment for severe depression though concerns persist about cognitive side-effects. While bitemporal electrode placement is the most commonly used form worldwide, right unilateral ECT causes less cognitive side-effects though historically it has been deemed less effective. Several randomized trials have now compared high-dose (>5× seizure threshold) unilateral ECT with moderate-dose (1.0-2.5× seizure threshold) bitemporal ECT to investigate if it is as effective as bitemporal ECT but still has less cognitive side-effects. We aimed to systematically review these trials and meta-analyse clinical and cognitive outcomes where appropriate. We searched PubMed, PsycINFO, Web of Science, Cochrane Library and EMBASE for randomized trials comparing these forms of ECT using the terms 'electroconvulsive' OR 'electroshock' AND 'trial'. Seven trials (n = 792) met inclusion criteria. Bitemporal ECT did not differ from high-dose unilateral ECT on depression rating change scores [Hedges's g = -0.03, 95% confidence interval (CI) -0.17 to 0.11], remission (RR 1.06, 95% CI 0.93-1.20), or relapse at 12 months (RR 1.42, 95% CI 0.90-2.23). There was an advantage for unilateral ECT on reorientation time after individual ECT sessions (mean difference in minutes = -8.28, 95% CI -12.86 to -3.70) and retrograde autobiographical memory (Hedges's g = -0.46, 95% CI -0.87 to -0.04) after completing an ECT course. There were no differences for general cognition, category fluency and delayed visual and verbal memory. High-dose unilateral ECT does not differ from moderate-dose bitemporal ECT in antidepressant efficacy but has some cognitive advantages.
Zeng, Zhikai; Li, Qingyun; Tian, Qiyu; Zhao, Panfeng; Xu, Xiao; Yu, Shukun; Piao, Xiangshu
2015-11-01
This study was conducted to evaluate the efficacy of a novel Buttiauxella phytase to pigs fed P-deficient, corn-soybean meal diets. One hundred and twenty crossbred piglets (9.53 ± 0.84 kg) were allocated to one of five treatments which consisted of four low P diets (0.61 % Ca and 0.46 % total P) supplemented with 0, 500, 1,000, or 20,000 FTU/kg phytase as well as a positive control diet (0.77 % Ca and 0.62 % total P). Each treatment had six replicated pens with four pigs per pen. Pigs were fed the experimental diets for 28 days. Phytase supplementation linearly improved (P < 0.05) average daily gain (ADG), feed conversion ratio (FCR), and apparent total tract digestibility (ATTD) of dry matter, gross energy, crude protein, Ca, and P in weaned pigs. Super high dosing with phytase (20,000 FTU/kg) further increased (P < 0.05) ADG compared with 500 FTU/kg phytase inclusion group, as well as ATTD of Ca and P. Metacarpal bone characteristics and several trace mineral concentration in bone, plasma, or organ tissues were linearly (P < 0.05) improved at increasing dose of phytase. Super high dosing with phytase (20,000 FTU/kg) supplementation improved (P < 0.05) Mn and Zn concentration in bone compared to normal dose of phytase supplementation (500 or 1,000 FTU/kg). In conclusion, supplementation of 500 FTU of Buttiauxella phytase/kg and above effectively hydrolyzed phytate in a low-P corn-soybean diet for pigs. In addition, a super high dosing with phytase (20,000 FTU/kg) improved macro- or micro mineral availability and growth performance.
Gentry, Chris A; Nguyen, Ann T
2013-12-01
Adverse events associated with high-dose trimethoprim-sulfamethoxazole (TMP-SMX) for outpatient infections, particularly those likely caused by community-acquired methicillin-resistant Staphylococcus aureus, have not been adequately characterized. Describe hyperkalemia and acute renal injury associated with high-dose TMP-SMX. An electronic medical record database retrospective study was conducted of outpatients receiving high-dose or low-dose TMP-SMX, comparing the incidences of hyperkalemia and acute renal injury. Of 6162 patients, more developed hyperkalemia (3.06% vs 1.05%, P < .0001) or acute renal injury (1.99% vs 0.700%, P = .0001) in the high-dose TMP-SMX group. Variables independently associated with hyperkalemia included age >58 years (odds ratio [OR] = 3.44; 95% CI = 1.86-7.0; P < .0001), concomitant receipt of an NSAID (OR = 1.71; 95% CI = 1.02-2.79; P = .044) or an ACE inhibitor (OR = 3.27; 95% CI = 2.06-5.14; P < .0001), high-dose TMP-SMX prescribed (OR = 2.92; 95% CI = 1.85-4.60; P < .0001), and baseline elevated serum creatinine (OR = 45.1; 95% CI = 21.7-93.2; P < .0001). Variables independently associated with acute renal injury included concomitant receipt of an ACE inhibitor (OR = 2.36; 95% CI = 1.01-5.24; P = .048) or a potassium supplement (OR = 4.10; 95% CI = 1.45-10.1; P = .010), high-dose TMP-SMX prescribed (OR = 3.70; 95% CI = 1.70-8.12; P = .0012), and baseline elevated serum creatinine (OR = 2110; 95% CI = 724-7980; P < .0001). Serum creatinine and potassium concentrations should be monitored in outpatients receiving high-dose TMP-SMX.
Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options
2013-01-01
Purpose Permanent low-dose-rate (LDR-BT) and temporary high-dose-rate (HDR-BT) brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never to be conducted comparing these two forms of brachytherapy, a comparative analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. The aim of this paper is to look for possible similarities and differences between both brachytherapy modalities. Indications and contraindications for monotherapy and for brachytherapy as a boost to external beam radiation therapy (EBRT) are presented. It is suggested that each of these techniques has attributes that advocates for one or the other. First, they represent the extreme ends of the spectrum with respect to dose rate and fractionation, and therefore have inherently different radiobiological properties. Low-dose-rate brachytherapy has the great advantage of being practically a one-time procedure, and enjoys a long-term follow-up database supporting its excellent outcomes and low morbidity. Low-dose-rate brachytherapy has been a gold standard for prostate brachytherapy in low risk patients since many years. On the other hand, HDR is a fairly invasive procedure requiring several sessions associated with a brief hospital stay. Although lacking in significant long-term data, it possesses the technical advantage of control over its postimplant dosimetry (by modulating the source dwell time and position), which is absent in LDR brachytherapy. This important difference in dosimetric control allows HDR doses to be escalated safely, a flexibility that does not exist for LDR brachytherapy. Conclusions Radiobiological models support the current clinical evidence for equivalent outcomes in localized prostate cancer with either LDR or HDR brachytherapy, using current dose regimens. At present, all available clinical data regarding these two techniques suggests that they are equally effective, stage for stage, in providing high tumor control rates. PMID:23634153
Chit, Ayman; Becker, Debbie L; DiazGranados, Carlos A; Maschio, Michael; Yau, Eddy; Drummond, Michael
2015-12-01
Adults aged 65 years and older account for most seasonal influenza-related hospital admissions and deaths. Findings from the randomised controlled FIM12 study showed that high-dose inactivated influenza vaccine is more effective than standard-dose vaccine for prevention of laboratory-confirmed influenza in this age group. We aimed to assess the economic impact of high-dose versus standard-dose influenza vaccine in participants in the FIM12 study population. The FIM12 study was a head-to-head randomised controlled trial in which 31,989 participants aged 65 years and older were randomly assigned (1:1) to receive either high-dose or standard-dose trivalent inactivated influenza vaccine over two influenza seasons (2011-12 and 2012-13). Data for health-care resource consumption obtained in the FIM12 study were summarised across vaccine groups. Unit costs obtained from standard US cost sources were applied to each resource item, including to the vaccines (high dose US$31·82, standard dose $12·04). Clinical illness data were mapped to existing quality-of-life data. The time horizon was one influenza season; however, quality-adjusted life-years (QALYs) lost due to death during the study were calculated over a lifetime. We calculated incremental cost-effectiveness ratios (ICERs) for high-dose versus standard-dose vaccine and used QALYs as an outcome in the cost-utility analysis. We undertook a probabilistic sensitivity analysis using bootstrapping to explore the effect of statistical uncertainty on the study results. Mean per-participant medical costs were lower in the high-dose vaccine group ($1376·72 [SD 6857·59]) than in the standard-dose group ($1492·64 [7447·14]; difference -$115·92 [95% CI -264·18 to 35·48]). Mean societal costs were likewise lower in the high-dose versus the standard-dose group ($1506·48 [SD 7305·19] vs $1634·50 [7952·99]; difference -$128·02 [95% CI -286·89 to 33·30]). Hospital admissions contributed 95% of the total health-care-payer cost and 87% of the total societal costs. The mean per-participant number of hospital admissions was 0·0937 (SD 0·3644) in the high-dose group and 0·1017 (0·3708) in the standard-dose group (difference -0·0080, 95% CI -0·0160 to -0·0003). The high-dose vaccine provided a gain in QALYs (mean 8·1502 QALYs gained per participant [SD 0·5693]) compared with the standard-dose vaccine (8·1499 QALYs [0·5697]) and, due to cost savings, dominated standard-dose vaccine in the cost-utility analysis. The probabilistic sensitivity analysis showed that the high-dose vaccine is 93% likely to be cost saving. High-dose trivalent inactivated influenza vaccine is a less costly and more effective alternative to the standard-dose vaccine, driven by a reduction in the number of hospital admissions. These findings are relevant to US health-care beneficiaries, providers, payers, and recommending bodies, especially those seeking to improve outcomes while containing costs. Sanofi Pasteur. Copyright © 2015 Elsevier Ltd. All rights reserved.
Long-term organ protection by doxazosin and/or quinapril as antihypertensive therapy.
Gallego-Delgado, Julio; Lazaro, Alberto; Gomez-Garre, Dulcenombre; Osende, Julio I; Gonzalez-Rubio, Maria L; Herraiz, Marta; Manzarbeitia, Félix; Fortes, José; Fernandez-Cruz, Arturo; Egido, Jesús
2006-01-01
Even with optimal blood pressure control, organ protection may also depend on the selected therapeutic regime. Angiotensin-converting enzyme inhibitors have been shown to provide excellent organ protection in hypertension, and may show dose-dependent protective effects. Adrenergic alpha blockers have been associated with an increased rate of heart failure in the Antihypertensive and Lipid-Lowering Treatment to Prevent Heart Attack Trial (ALLHAT) and Vasodilator-Heart Failure Trial (V-HeFT). This has been related to a proapoptotic effect of this drug in cardiomyocytes. Our purpose is to compare the heart and renal protection of a high quinapril dose, with a combined low quinapril dose plus doxazosin, in an animal model of chronic hypertension. Uninephrectomized spontaneously hypertensive 12-week-old rats were treated for 36 weeks with either quinapril or a combination of doxazosin plus a low quinapril dose. Tight blood pressure control was achieved with both treatments. Renal and cardiac protection was assessed by different parameters, and cardiac apoptosis was evaluated by active caspase-3, apoptotic protein and heat shock protein levels. Untreated hypertensive and normotensive rats were included as controls. Both treatments showed significant heart and renal protection compared with untreated animals. Both therapeutic regimes showed similar protection in renal and cardiac pathology, coronary media fibrosis, myocardial apoptosis and cardiac index. Proteinuria and left ventricular hypertrophy regression were significantly lower in the quinapril group compared with the combined treatment group. Blood pressure control with a high quinapril dose provided higher organ protection than a combined therapy with a lower quinapril dose. This effect was not due to a deleterious effect of doxazosin.
Werumeus Buning, Jorien; Brummelman, Pauline; Koerts, Janneke; Dullaart, Robin P F; van den Berg, Gerrit; van der Klauw, Melanie M; Tucha, Oliver; Wolffenbuttel, Bruce H R; van Beek, André P
2015-05-01
A wide variety in hydrocortisone (HC) substitution dose-regimens are considered physiological for patients with secondary adrenal insufficiency (SAI). However, it is likely that cognition is negatively influenced by higher cortisol exposure to the brain. To examine the effects of a high physiological HC dose in comparison to a low physiological HC dose on cognition. This study was a randomized double blind cross-over study at the University Medical Center Groningen. This study is registered with ClinicalTrials.gov, number NCT01546922. Forty-seven patients (29 males, 18 females; mean [SD] age, 51 [14] years, range 19-73) with SAI participated. Patients randomly received first a low dose of HC (0.2-0.3 mg/kg body weight/day) during 10 weeks followed by a high dose (0.4-0.6 mg/kg body weight/day) for another 10 weeks, or vice versa. HC substitution was given in three divided doses with the highest dose in the morning. Cognitive performance (memory, attention, executive functioning and social cognition) of patients was measured at baseline and after each treatment period using a battery of 12 standardized cognitive tests. The higher dose of HC resulted in significantly higher systemic cortisol exposure for example measured at 1h after first dose ingestion (mean [SD], low dose: 653 [281] nmol/L; high dose: 930 [148] nmol/L; P<0.001). No differences in cognitive performance were found between the two dose regimens. No negative influence on memory, attention, executive functioning and social cognition was observed after 10 weeks of treatment with a higher physiological dose of HC in patients with SAI when compared to a lower dose. Copyright © 2015 Elsevier Ltd. All rights reserved.
Liu, Rong; Li, Xi; Zhang, Wei; Zhou, Hong-Hao
2015-01-01
Objective Multiple linear regression (MLR) and machine learning techniques in pharmacogenetic algorithm-based warfarin dosing have been reported. However, performances of these algorithms in racially diverse group have never been objectively evaluated and compared. In this literature-based study, we compared the performances of eight machine learning techniques with those of MLR in a large, racially-diverse cohort. Methods MLR, artificial neural network (ANN), regression tree (RT), multivariate adaptive regression splines (MARS), boosted regression tree (BRT), support vector regression (SVR), random forest regression (RFR), lasso regression (LAR) and Bayesian additive regression trees (BART) were applied in warfarin dose algorithms in a cohort from the International Warfarin Pharmacogenetics Consortium database. Covariates obtained by stepwise regression from 80% of randomly selected patients were used to develop algorithms. To compare the performances of these algorithms, the mean percentage of patients whose predicted dose fell within 20% of the actual dose (mean percentage within 20%) and the mean absolute error (MAE) were calculated in the remaining 20% of patients. The performances of these techniques in different races, as well as the dose ranges of therapeutic warfarin were compared. Robust results were obtained after 100 rounds of resampling. Results BART, MARS and SVR were statistically indistinguishable and significantly out performed all the other approaches in the whole cohort (MAE: 8.84–8.96 mg/week, mean percentage within 20%: 45.88%–46.35%). In the White population, MARS and BART showed higher mean percentage within 20% and lower mean MAE than those of MLR (all p values < 0.05). In the Asian population, SVR, BART, MARS and LAR performed the same as MLR. MLR and LAR optimally performed among the Black population. When patients were grouped in terms of warfarin dose range, all machine learning techniques except ANN and LAR showed significantly higher mean percentage within 20%, and lower MAE (all p values < 0.05) than MLR in the low- and high- dose ranges. Conclusion Overall, machine learning-based techniques, BART, MARS and SVR performed superior than MLR in warfarin pharmacogenetic dosing. Differences of algorithms’ performances exist among the races. Moreover, machine learning-based algorithms tended to perform better in the low- and high- dose ranges than MLR. PMID:26305568
Al-Hammadi, Noora; Caparrotti, Palmira; Naim, Carole; Hayes, Jillian; Rebecca Benson, Katherine; Vasic, Ana; Al-Abdulla, Hissa; Hammoud, Rabih; Divakar, Saju; Petric, Primoz
2018-03-01
During radiotherapy of left-sided breast cancer, parts of the heart are irradiated, which may lead to late toxicity. We report on the experience of single institution with cardiac-sparing radiotherapy using voluntary deep inspiration breath hold (V-DIBH) and compare its dosimetric outcome with free breathing (FB) technique. Left-sided breast cancer patients, treated at our department with postoperative radiotherapy of breast/chest wall +/- regional lymph nodes between May 2015 and January 2017, were considered for inclusion. FB-computed tomography (CT) was obtained and dose-planning performed. Cases with cardiac V25Gy ≥ 5% or risk factors for heart disease were coached for V-DIBH. Compliant patients were included. They underwent additional CT in V-DIBH for planning, followed by V-DIBH radiotherapy. Dose volume histogram parameters for heart, lung and optimized planning target volume (OPTV) were compared between FB and BH. Treatment setup shifts and systematic and random errors for V-DIBH technique were compared with FB historic control. Sixty-three patients were considered for V-DIBH. Nine (14.3%) were non-compliant at coaching, leaving 54 cases for analysis. When compared with FB, V-DIBH resulted in a significant reduction of mean cardiac dose from 6.1 +/- 2.5 to 3.2 +/- 1.4 Gy (p < 0.001), maximum cardiac dose from 51.1 +/- 1.4 to 48.5 +/- 6.8 Gy (p = 0.005) and cardiac V25Gy from 8.5 +/- 4.2 to 3.2 +/- 2.5% (p < 0.001). Heart volumes receiving low (10-20 Gy) and high (30-50 Gy) doses were also significantly reduced. Mean dose to the left anterior coronary artery was 23.0 (+/- 6.7) Gy and 14.8 (+/- 7.6) Gy on FB and V-DIBH, respectively (p < 0.001). Differences between FB- and V-DIBH-derived mean lung dose (11.3 +/- 3.2 vs. 10.6 +/- 2.6 Gy), lung V20Gy (20.5 +/- 7 vs. 19.5 +/- 5.1 Gy) and V95% for the OPTV (95.6 +/- 4.1 vs. 95.2 +/- 6.3%) were non-significant. V-DIBH-derived mean shifts for initial patient setup were ≤ 2.7 mm. Random and systematic errors were ≤ 2.1 mm. These results did not differ significantly from historic FB controls. When compared with FB, V-DIBH demonstrated high setup accuracy and enabled significant reduction of cardiac doses without compromising the target volume coverage. Differences in lung doses were non-significant.
Beierholm, Anders R; Ottosson, Rickard O; Lindvold, Lars R; Behrens, Claus F; Andersen, Claus E
2011-05-21
A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse with millimetre spatial resolution. To demonstrate the applicability of the system in complex radiotherapy fields, output factors and per cent depth dose measurements were performed in solid water for a 6 MV photon beam and compared with Monte Carlo simulated doses for square fields down to 0.6 cm × 0.6 cm size. No significant differences between measurements and simulations were observed. The temporal resolution of the system was demonstrated by measuring dose per pulse, beam start-up transients and the quality factor for 6 MV. The precision of dose per pulse measurements was within 2.7% (1 SD) for a 10 cm × 10 cm field at 10 cm depth. The dose per pulse behaviour compared well with linac target current measurements and accumulated dose measurements, and the system was able to resolve transient dose delivery differences between two Varian linac builds. The system therefore shows promise for reference dosimetry and quality assurance of complex radiotherapy treatments.
Mirsch, Johanna; Tommasino, Francesco; Frohns, Antonia; Conrad, Sandro; Durante, Marco; Scholz, Michael; Friedrich, Thomas; Löbrich, Markus
2015-01-01
Charged particles are increasingly used in cancer radiotherapy and contribute significantly to the natural radiation risk. The difference in the biological effects of high-energy charged particles compared with X-rays or γ-rays is determined largely by the spatial distribution of their energy deposition events. Part of the energy is deposited in a densely ionizing manner in the inner part of the track, with the remainder spread out more sparsely over the outer track region. Our knowledge about the dose distribution is derived solely from modeling approaches and physical measurements in inorganic material. Here we exploited the exceptional sensitivity of γH2AX foci technology and quantified the spatial distribution of DNA lesions induced by charged particles in a mouse model tissue. We observed that charged particles damage tissue nonhomogenously, with single cells receiving high doses and many other cells exposed to isolated damage resulting from high-energy secondary electrons. Using calibration experiments, we transformed the 3D lesion distribution into a dose distribution and compared it with predictions from modeling approaches. We obtained a radial dose distribution with sub-micrometer resolution that decreased with increasing distance to the particle path following a 1/r2 dependency. The analysis further revealed the existence of a background dose at larger distances from the particle path arising from overlapping dose deposition events from independent particles. Our study provides, to our knowledge, the first quantification of the spatial dose distribution of charged particles in biologically relevant material, and will serve as a benchmark for biophysical models that predict the biological effects of these particles. PMID:26392532
Bhandari, Sunil
2011-01-01
The clinical need to be able to administer high doses of intravenous iron conveniently in a single rapid infusion has been addressed by the recent introduction of ferric carboxymaltose and subsequently iron isomaltoside 1000. Neither requires a test dose. Ferric carboxymaltose can be administered at 15 mg/kg body weight to a maximum dose of 1000 mg, whereas iron isomaltoside 1000 can be administered at 20 mg/kg body weight. The ability to give high doses of iron is important in the context of managing iron deficiency anemia in a number of clinical conditions where demands for iron are high (including chronic blood loss associated with inflammatory bowel disease, menorrhagia, and chronic kidney disease). It is also an important component in the strategy as an alternative to a blood transfusion. Affordability is a key issue for health services. This study was a comparative analysis of the costs of administering the newly available intravenous iron formulations against standard practice (blood transfusion, intravenous iron sucrose) by considering the cost of this treatment option plus nursing costs associated with administration, equipment for administration, and patient transportation in the secondary care (hospital) setting across three dosage levels (600 mg, 1000 mg, and 1600 mg). The analysis indicates that the use of iron isomaltoside 1000 results in a net saving when compared with iron sucrose, blood, and ferric carboxymaltose. At 600 mg and 1000 mg doses, it is cheaper than low-molecular-weight iron dextran but more expensive at a dose of 1600 mg. However, it takes six hours to administer low-molecular-weight iron dextran at this dose level, which is inconvenient and reduces patient throughput (productivity).
Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi
2010-12-20
A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.
Bhandari, Sunil
2011-01-01
Background The clinical need to be able to administer high doses of intravenous iron conveniently as a rapid infusion has been addressed by the recent introduction of ferric carboxymaltose and subsequently iron isomaltoside 1000. Neither requires a test dose. The maximum dose of ferric carboxymaltose is 1000 mg. The maximum dose of iron isomaltoside 1000 is based on 20 mg/kg body weight without a specified ceiling dose, thereby increasing the scope of being able to achieve total iron repletion with a single infusion. This ability to give high doses of iron is important in the context of managing iron deficiency anemia, which is associated with a number of clinical conditions where demands for iron are high. It is also an important component of the strategy as an alternative to blood transfusion. Affordability is a key issue for health services. Recent price changes affecting iron sucrose and ferric carboxymaltose, plus modifications to the manufacturers’ prescribing information, have provoked this update. Methods This study is a comparative analysis of the costs of acquiring and administering the newly available intravenous iron formulations against standard treatments in the hospital setting. The costs include the medication, nursing costs, equipment, and patient transportation. Three dosage levels (600 mg, 1000 mg, and 1600 mg) are considered. Results and conclusion The traditional standard treatments, blood and iron sucrose, cost more than the alternative intravenous iron preparations across the dose spectrum and sensitivities. Low molecular weight iron dextran is the least expensive option at the 1600 mg dose level but has the caveat of a prolonged administration time and requirement for a test dose. At 600 mg and 1000 mg dose levels, both iron isomaltoside 1000 and ferric carboxymaltose are more economical than low molecular weight iron dextran. Iron isomaltoside 1000 is less expensive than ferric carboxymaltose at all dose levels. Newly available iron preparations appear to be clinically promising, cost effective, and practical alternatives to current standards of iron repletion. PMID:22241947
Schwartz, Jill L.; Rountree, Wes; Kashuba, Angela D. M.; Brache, Vivian; Creinin, Mitchell D.; Poindexter, Alfred; Kearney, Brian P.
2011-01-01
Background Tenofovir (TFV) gel is being evaluated as a microbicide with pericoital and daily regimens. To inhibit viral replication locally, an adequate concentration in the genital tract is critical. Methods and Findings Forty-nine participants entered a two-phase study: single-dose (SD) and multi-dose (MD), were randomized to collection of genital tract samples (endocervical cells [ECC], cervicovaginal aspirate and vaginal biopsies) at one of seven time points [0.5, 1, 2, 4, 6, 8, or 24 hr(s)] post-dose following SD exposure of 4 mL 1% TFV gel and received a single dose. Forty-seven were randomized to once (QD) or twice daily (BID) dosing for 2 weeks and to collection of genital tract samples at 4, 8 or 24 hrs after the final dose, but two discontinued prior to gel application. Blood was collected during both phases at the seven times post-dose. TFV exposure was low in blood plasma for SD and MD; median Cmax was 4.0 and 3.4 ng/mL, respectively (C≤29 ng/mL). TFV concentrations were high in aspirates and tissue after SD and MD, ranging from 1.2×104 to 9.9×106 ng/mL and 2.1×102 to 1.4×106 ng/mL, respectively, and did not noticeably differ between proximal and distal tissue. TFV diphosphate (TFV-DP), the intracellular active metabolite, was high in ECC, ranging from 7.1×103 to 8.8×106 ng/mL. TFV-DP was detectable in approximately 40% of the tissue samples, ranging from 1.8×102 to 3.5×104 ng/mL. AUC for tissue TFV-DP was two logs higher after MD compared to SD, with no noticeable differences when comparing QD and BID. Conclusions Single-dose and multiple-dose TFV gel exposure resulted in high genital tract concentrations for at least 24 hours post-dose with minimal systemic absorption. These results support further study of TFV gel for HIV prevention. Trial registration ClinicalTrials.gov NCT00561496 PMID:22039430
SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campos, L T; Almeida, C E V de
Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, whichmore » is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.« less
Comparison of Individual Radiosensitivity to γ-Rays and Carbon Ions
Shim, Grace; Normil, Marie Delna; Testard, Isabelle; Hempel, William M.; Ricoul, Michelle; Sabatier, Laure
2016-01-01
Carbon ions are an up-and-coming ion species, currently being used in charged particle radiotherapy. As it is well established that there are considerable interindividual differences in radiosensitivity in the general population that can significantly influence clinical outcomes of radiotherapy, we evaluate the degree of these differences in the context of carbon ion therapy compared with conventional radiotherapy. In this study, we evaluate individual radiosensitivity following exposure to carbon-13 ions or γ-rays in peripheral blood lymphocytes of healthy individuals based on the frequency of ionizing radiation (IR)-induced DNA double strand breaks (DSBs) that was either misrepaired or left unrepaired to form chromosomal aberrations (CAs) (simply referred to here as DSBs for brevity). Levels of DSBs were estimated from the scoring of CAs visualized with telomere/centromere-fluorescence in situ hybridization (TC-FISH). We examine radiosensitivity at the dose of 2 Gy, a routinely administered dose during fractionated radiotherapy, and we determined that a wide range of DSBs were induced by the given dose among healthy individuals, with highly radiosensitive individuals harboring more IR-induced breaks in the genome than radioresistant individuals following exposure to the same dose. Furthermore, we determined the relative effectiveness of carbon irradiation in comparison to γ-irradiation in the induction of DSBs at each studied dose (isodose effect), a quality we term “relative dose effect” (RDE). This ratio is advantageous, as it allows for simple comparison of dose–response curves. At 2 Gy, carbon irradiation was three times more effective in inducing DSBs compared with γ-irradiation (RDE of 3); these results were confirmed using a second cytogenetic technique, multicolor-FISH. We also analyze radiosensitivity at other doses (0.2–15 Gy), to represent hypo- and hyperfractionation doses and determined that RDE is dose dependent: high ratios at low doses, and approaching 1 at high doses. These results could have clinical implications as IR-induced DNA damage and the ensuing CAs and genomic instability can have significant cellular consequences that could potentially have profound implications for long-term human health after IR exposure, such as the emergence of secondary cancers and other pathobiological conditions after radiotherapy. PMID:27379201
Optimization of Craniospinal Irradiation for Pediatric Medulloblastoma Using VMAT and IMRT.
Al-Wassia, Rolina K; Ghassal, Noor M; Naga, Adly; Awad, Nesreen A; Bahadur, Yasir A; Constantinescu, Camelia
2015-10-01
Intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) provide highly conformal target radiation doses, but also expose large volumes of healthy tissue to low-dose radiation. With improving survival, more children with medulloblastoma (MB) are at risk of late adverse effects of radiotherapy, including secondary cancers. We evaluated the characteristics of IMRT and VMAT craniospinal irradiation treatment plans in children with standard-risk MB to compare radiation dose delivery to target organs and organs at risk (OAR). Each of 10 children with standard-risk MB underwent both IMRT and VMAT treatment planning. Dose calculations used inverse planning optimization with a craniospinal dose of 23.4 Gy followed by a posterior fossa boost to 55.8 Gy. Clinical and planning target volumes were demarcated on axial computed tomography images. Dose distributions to target organs and OAR for each planning technique were measured and compared with published dose-volume toxicity data for pediatric patients. All patients completed treatment planning for both techniques. Analyses and comparisons of dose distributions and dose-volume histograms for the planned target volumes, and dose delivery to the OAR for each technique demonstrated the following: (1) VMAT had a modest, but significantly better, planning target volume-dose coverage and homogeneity compared with IMRT; (2) there were different OAR dose-sparing profiles for IMRT versus VMAT; and (3) neither IMRT nor VMAT demonstrated dose reductions to the published pediatric dose limits for the eyes, the lens, the cochlea, the pituitary, and the brain. The use of both IMRT and VMAT provides good target tissue coverage and sparing of the adjacent tissue for MB. Both techniques resulted in OAR dose delivery within published pediatric dose guidelines, except those mentioned above. Pediatric patients with standard-risk MB remain at risk for late endocrinologic, sensory (auditory and visual), and brain functional impairments.
Werumeus Buning, Jorien; Touw, Daan J; Brummelman, Pauline; Dullaart, Robin P F; van den Berg, Gerrit; van der Klauw, Melanie M; Kamp, Jasper; Wolffenbuttel, Bruce H R; van Beek, André P
2017-06-01
This study aimed at comparing pharmacokinetics of two different doses of hydrocortisone (HC) in patients with secondary adrenal insufficiency (SAI). Forty-six patients with SAI participated in this randomized double-blind crossover study. Patients received two different doses of HC (0.2-0.3mg HC/kg body weight/day and 0.4-0.6mg HC/kg body weight/day). One- and two-compartment population models for plasma free cortisol, plasma total cortisol and salivary cortisol were parameterized. The individual pharmacokinetic parameters clearance (CL), volume of distribution (V d ), elimination half-life (t 1/2 ), maximum concentration (C max ), and area under the curve (AUC) were calculated. The one-compartment models gave a better description of the data compared to the two-compartment models. Weight-adjusted dosing reduced variability in cortisol exposure with comparable AUCs between weight groups. However, there was large inter-individual variation in CL and V d of plasma free cortisol, plasma total cortisol and salivary cortisol. As a consequence, AUC 24h varied more than 10 fold. Cortisol exposure was increased with the higher dose, but this was dose proportional only for free cortisol concentrations and not for total cortisol. Cortisol concentrations after a doubling of the dose were only dose proportional for free cortisol. HC pharmacokinetics can differ up to 10-fold inter-individually and individual adjustment of treatment doses may be necessary. Doubling of the HC dose in fast metabolizers (patients that showed relative low AUC and thus high clearance compared to other patients), does not result in significantly enhanced exposure during large parts of the day and these patients may need other management strategies. Copyright © 2017 Elsevier Inc. All rights reserved.
Modern dosimetric tools for 60Co irradiation at high containment laboratories
Twardoski, Barri; Feldmann, Heinz; Bloom, Marshall E.; Ward, Joe
2011-01-01
Purpose To evaluate an innovative photo-fluorescent film as a routine dosimetric tool during 60Co irradiations at a high containment biological research laboratory, and to investigate whether manufacturer-provided chamber exposure rates can be used to accurately administer a prescribed dose to biological specimens. Materials and methods Photo-fluorescent, lithium fluoride film dosimeters and National Institutes of Standards and Technology (NIST) transfer dosimeters were co-located in a self-shielded 60Co irradiator and exposed to γ-radiation with doses ranging from 5–85 kGy. Film dose-response relationships were developed for varying temperatures simulating conditions present when irradiating infectious biological specimens. Dose measurement results from NIST transfer dosimeters were compared to doses predicted using manufacturer-provided irradiator chamber exposure rates. Results The film dosimeter exhibited a photo-fluorescent response signal that was consistent and nearly linear in relationship to γ-radiation exposure over a wide dose range. The dosimeter response also showed negligible effects from dose fractionization and humidity. Significant disparities existed between manufacturer-provided chamber exposure rates and actual doses administered. Conclusion This study demonstrates the merit of utilizing dosimetric tools to validate the process of exposing dangerous and exotic biological agents to γ-radiation at high containment laboratories. The film dosimeter used in this study can be utilized to eliminate potential for improperly administering γ-radiation doses. PMID:21961968
Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay
2014-12-23
The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a "sandwich" technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the "sandwich" technique to "classic" - interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue "hot spots" and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36-81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1-47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality.
Shuryak, Igor; Loucas, Bradford D.; Cornforth, Michael N.
2017-01-01
Recent technological advances allow precise radiation delivery to tumor targets. As opposed to more conventional radiotherapy—where multiple small fractions are given—in some cases, the preferred course of treatment may involve only a few (or even one) large dose(s) per fraction. Under these conditions, the choice of appropriate radiobiological model complicates the tasks of predicting radiotherapy outcomes and designing new treatment regimens. The most commonly used model for this purpose is the venerable linear-quadratic (LQ) formalism as it applies to cell survival. However, predictions based on the LQ model are frequently at odds with data following very high acute doses. In particular, although the LQ predicts a continuously bending dose–response relationship for the logarithm of cell survival, empirical evidence over the high-dose region suggests that the survival response is instead log-linear with dose. Here, we show that the distribution of lethal chromosomal lesions among individual human cells (lymphocytes and fibroblasts) exposed to gamma rays and X rays is somewhat overdispersed, compared with the Poisson distribution. Further, we show that such overdispersion affects the predicted dose response for cell survival (the fraction of cells with zero lethal lesions). This causes the dose response to approximate log-linear behavior at high doses, even when the mean number of lethal lesions per cell is well fitted by the continuously curving LQ model. Accounting for overdispersion of lethal lesions provides a novel, mechanistically based explanation for the observed shapes of cell survival dose responses that, in principle, may offer a tractable and clinically useful approach for modeling the effects of high doses per fraction. PMID:29312888
Khazaal, Yasser; Preisig, Martin; Chatton, Anne; Kaufmann, Nadine; Bilancioni, Romain; Eap, Chin B
2013-09-01
The use of quetiapine for treatment of bipolar disorders at a higher dosage than the licensed range is not unusual in clinical practice. Quetiapine is predominantly metabolised by cytochrome P450 3A4 (CYP3A4) and to a lesser extent by CYP2D6. The large interindividual variability of those isozyme activities could contribute to the variability observed in quetiapine dosage. The aim of the present study is to evaluate if the use of high dosages of quetiapine in some patients, as compared to patients treated with a dosage in the licensed range (up to 800 mg/day), could be explained by a high activity of CYP3A4 and/or of CYP2D6. CYP3A4 activities were determined using the midazolam metabolic ratio in 21 bipolar and schizoaffective bipolar patients genotyped for CYP2D6. 9 patients were treated with a high quetiapine dosage (mean ± SD, median; range: 1467 ± 625, 1200; 1000-3000 mg/day) and 11 with a normal quetiapine dosage (433 ± 274, 350; 100-800 mg/day). One patient in the high dose and one patient in the normal dose groups were genotyped as CYP2D6 ultrarapid metabolizers. CYP3A4 activities were not significantly different between the two groups (midazolam metabolic ratio: 9.4 ± 8.2; 6.2; 1.7-26.8 vs 3.9 ± 2.3; 3.8; 1.5-7.6, in the normal dose group as compared to the high dose group, respectively, NS). The use of high quetiapine dosage for the patients included in the present study cannot be explained by variations in pharmacokinetics parameters such as a high activity of CYP3A4 and/or of CYP2D6.
Measurement and effects of MOSKIN detectors on skin dose during high energy radiotherapy treatment.
Alnawaf, Hani; Butson, Martin; Yu, Peter K N
2012-09-01
During in vivo dosimetry for megavoltage X-ray beams, detectors such as diodes, Thermo luminescent dosimeters (TLD's) and MOSFET devices are placed on the patient's skin. This of course will affect the skin dose delivered during that fraction of the treatment. Whilst the overall impact on increasing skin dose would be minimal, little has been quantified concerning the level of increase in absorbed dose, in vivo dosimeters produce when placed in the beams path. To this extent, measurements have been made and analysis performed on dose changes caused by MOSKIN, MOSFET, skin dose detectors. Maximum increases in skin dose were measured as 15 % for 6 MV X-rays and 10 % for 10 MV X-rays at the active crystal of the MOSKIN device which is the thickest part of the detector. This is compared to 32 and 26 % for a standard 1 mm thick LiF TLD at 10 × 10 cm(2) field size for 6 and 10 MV X-rays respectively. Radiochromic film, EBT2 has been shown to provide a high resolution 2 dimensional map of skin dose from these detectors and measures the effects of in vivo dosimeters used for radiotherapy dose assessment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mell, Loren K.; Tiryaki, Hanifi; Ahn, Kang-Hyun
2008-08-01
Purpose: To compare bone marrow-sparing intensity-modulated pelvic radiotherapy (BMS-IMRT) with conventional (four-field box and anteroposterior-posteroanterior [AP-PA]) techniques in the treatment of cervical cancer. Methods and Materials: The data from 7 cervical cancer patients treated with concurrent chemotherapy and IMRT without BMS were analyzed and compared with data using four-field box and AP-PA techniques. All plans were normalized to cover the planning target volume with the 99% isodose line. The clinical target volume consisted of the pelvic and presacral lymph nodes, uterus and cervix, upper vagina, and parametrial tissue. Normal tissues included bowel, bladder, and pelvic bone marrow (PBM), which comprisedmore » the lumbosacral spine and ilium and the ischium, pubis, and proximal femora (lower pelvis bone marrow). Dose-volume histograms for the planning target volume and normal tissues were compared for BMS-IMRT vs. four-field box and AP-PA plans. Results: BMS-IMRT was superior to the four-field box technique in reducing the dose to the PBM, small bowel, rectum, and bladder. Compared with AP-PA plans, BMS-IMRT reduced the PBM volume receiving a dose >16.4 Gy. BMS-IMRT reduced the volume of ilium, lower pelvis bone marrow, and bowel receiving a dose >27.7, >18.7, and >21.1 Gy, respectively, but increased dose below these thresholds compared with the AP-PA plans. BMS-IMRT reduced the volume of lumbosacral spine bone marrow, rectum, small bowel, and bladder at all dose levels in all 7 patients. Conclusion: BMS-IMRT reduced irradiation of PBM compared with the four-field box technique. Compared with the AP-PA technique, BMS-IMRT reduced lumbosacral spine bone marrow irradiation and reduced the volume of PBM irradiated to high doses. Therefore BMS-IMRT might reduce acute hematologic toxicity compared with conventional techniques.« less
A new radiotherapy surface dose detector:the MOSFET.
Butson, M J; Rozenfeld, A; Mathur, J N; Carolan, M; Wong, T P; Metcalfe, P E
1996-05-01
Radiotherapy x-ray and electron beam surface doses are accurately measurable by use of a MOS-FET detector system. The MOSFET (Metal Oxide Semiconductor Field Effect Transistor) is approximately 200-microns in diameter and consists of a 0.5-microns Al electrode on top of a 1-microns SiO2 and 300-microns Si substrate. Results for % surface dose were within +/- 2% compared to the Attix chamber and within +/- 3% of TLD extrapolation results for normally incident beams. Detectors were compared using different energies, field size, and beam modifying devices such as block trays and wedges. Percentage surface dose for 10 x 10-cm and 40 x 40-cm field size for 6-MV x rays at 100-cm SSD using the MOSFET were 16% and 42% of maximum, respectively. Factors such as its small size, immediate retrieval of results, high accuracy attainable from low applied doses, and as the MOSFET records its dose history make it a suitable in vivo dosimeter where surface and skin doses need to be determined. This can be achieved within part of the first fraction of dose (i.e., only 10 cGy is required.)
Buza, Joram; Mpolya, Emmanuel A.; Angelo, Teckla; Kinung'hi, Safari M.
2017-01-01
Administering more than one treatment may increase Praziquantel cure and egg reduction rates, thereby hastening achievement of schistosomiasis transmission control. A total of 431 S. mansoni-infected schoolchildren were randomized to receive either a single or repeated 40 mg/kg Praziquantel dose. Heights, weights, and haemoglobin levels were determined using a stadiometer, weighing scale, and HemoCue, respectively. At 8 weeks, cure rate was higher on repeated dose (93.10%) compared to single dose (68.68%) (p < 0.001). The egg reduction rate was higher on repeated dose (97.54%) compared to single dose (87.27%) (p = 0.0062). Geometric mean egg intensity was lower among those on repeated dose (1.30 epg) compared to single dose (3.18 epg) (p = 0.036) but not at 5 (p > 0.05) and 8 (p > 0.05) months with no difference in reinfection rate. No difference in the prevalence of stunting was observed between the two treatment regimens (p > 0.05) at 8 months, but there was an increase in the prevalence of wasting among those on repeated dose (p < 0.001). There was an increase in the mean haemoglobin levels at 8 months with no difference between the two arms (p > 0.05). To achieve reduction of transmission intensity and disease control in highly endemic areas, repeated treatments alone may not be sufficient. This trial was registered with PACTR201601001416338. PMID:29094048
Ben Abdennebi, A; Aubry, S; Ounalli, L; Fayache, M S; Delabrousse, E; Petegnief, Y
2017-01-01
To estimate fetal absorbed doses for pregnant women pelvimetry, a comparative study between EOS imaging system and low-dose spiral CT-scanner was carried out. For this purpose three different studies were investigated: in vivo, in vitro and Monte Carlo calculations. In vivo dosimetry was performed, using OSL NanoDot dosimeters, to determine the dose to the skin of twenty pregnant women. In vitro studies were established by using a cubic phantom of water, in order to estimate the out of field doses. In the latter study, OSLDs were placed at depths corresponding to the lowest, average and highest position of the uterus. Monte Carlo calculations of effective doses to high radio-sensitive organs were established, using PCXMC and CTExpo software suites for EOS imaging system and CT-scanner, respectively. The EOS imaging system reduces radiation exposure 4 to 8 times compared to the CT-scanner. The entrance skin doses were 74% (p-values <0.01) higher with the CT-scanner than with the EOS system. In the out of field region, the measured doses of the EOS system were reduced by 80% (p-values <0.02). Monte Carlo calculations confirmed that effective doses to organs are less accentuated for EOS than for CT pelvimetry. The EOS system is less irradiating than the CT exam. The out-of-field dose which is significant, is lower in the EOS than in the CT-scanner and could be reduced even further by optimizing the time used for image acquisition. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Brown, Matthew A; Johánek, Viktor; Hemminger, John C
2008-02-01
A unique dosing system for the production of hydroxyl radicals under high vacuum for the study of environmental heterogeneous reactions is described. Hydroxyl radicals are produced by the photodissociation of a hydrogen peroxide aqueous gas mixture with 254 nm radiation according to the reaction H2O2+hnu (254 nm)-->OH+OH. Under the conditions of the current design, 0.6% conversion of hydrogen peroxide is expected yielding a hydroxyl number density on the order of 10(10) molecules/cm3. The flux distribution of the dosing system is calculated using a Monte Carlo simulation method and compared with the experimentally determined results. The performance of this unique hydroxyl dosing system is demonstrated for the heterogeneous reaction with a solid surface of potassium iodide. Coupling of the hydroxyl radical dosing system to a quantitative surface analysis system should help provide molecular level insight into detailed reaction mechanisms.
Maingi, R.; Osborne, T. H.; Bell, M. G.; ...
2014-11-04
In this paper, the effects of a pre-discharge lithium evaporation variation on highly shaped discharges in the National Spherical Torus Experiment (NSTX) are documented. Lithium wall conditioning (‘dose’) was routinely applied onto graphite plasma facing components between discharges in NSTX, partly to reduce recycling. Reduced D α emission from the lower and upper divertor and center stack was observed, as well as reduced midplane neutral pressure; the magnitude of reduction increased with the pre-discharge lithium dose. Improved energy confinement, both raw τ E and H-factor normalized to scalings, with increasing lithium dose was also observed. At the highest doses, wemore » also observed elimination of edge-localized modes. The midplane edge plasma profiles were dramatically altered, comparable to lithium dose scans at lower shaping, where the strike point was farther from the lithium deposition centroid. As a result, this indicates that the benefits of lithium conditioning should apply to the highly shaped plasmas planned in NSTX-U.« less
Poling, A; Cleary, J; Berens, K; Thompson, T
1990-12-01
The purpose of the present study was to examine the effects of haloperidol (0.3-10 mg/kg), molindone (0.3-5.6 mg/kg), mesoridazine (0.3-10) and thioridazine (0.3-25 mg/kg) on the behavior of pigeons exposed to a repeated acquisition procedure. At sufficiently high doses, each of these neuroleptics increased error rates (interfered with learning) and reduced rate of responding. When the drugs were compared on the basis of absolute doses administered, haloperidol disrupted behavior at doses considerably lower than the other drugs. If, however, chlorpromazine equivalent doses were examined, haloperidol was the least disruptive of the four drugs. Comparing the degree of behavioral disruption produced by the four drugs with their relative neuroreceptor affinities for dopamine D-2, cholinergic muscarinic, histamine H1, alpha-1 adrenergic and alpha-2 adrenergic receptors suggests that behavioral disruption cannot be attributed in any simple way to dopamine or acetylcholine receptor blockade. The relationship between the behavioral effects of neuroleptics and their simple neuropharmacological actions must be considered as highly tentative.
Wang, Le; Peng, Pingan; Zhang, Ou; Xu, Xiaohan; Yang, Shiwei; Zhao, Yingxin; Zhou, Yujie
2014-01-01
Background Evidence suggests that high-dose statin pretreatment may reduce the risk of periprocedural myocardial infarction (PMI) and major adverse cardiac events (MACE) for certain patients; however, previous analyses have not considered patients with a history of statin maintenance treatment. In this meta-analysis of randomized controlled trials (RCTs), we reevaluated the efficacy of short-term high-dose statin pretreatment to prevent PMI and MACE in an expanded set of patients undergoing elective percutaneous coronary intervention. Methods We searched the PubMed/Medline database for RCTs that compared high-dose statin pretreatment with no statin or low-dose statin pretreatment as a prevention of PMI and MACE. We evaluated the incidence of PMI and MACE, including death, spontaneous myocardial infarction, and target vessel revascularization at the longest follow-up for each study for subgroups stratified by disease classification and prior low-dose statin treatment. Results Twenty-four RCTs with a total of 5,526 patients were identified. High-dose statin pretreatment was associated with 59% relative reduction in PMI (odds ratio [OR]: 0.41; 95% confidence interval [CI]: 0.34–0.49; P<0.00001) and 39% relative reduction in MACE (OR: 0.61; 95% CI: 0.45–0.83; P = 0.002). The benefit of high-dose statin pretreatment on MACE was significant for statin-naive patients (OR: 0.69; 95% CI: 0.50–0.95; P = 0.02) and prior low dose statin-treated patients (OR: 0.28; 95% CI: 0.12–0.65; P = 0.003); and for patients with acute coronary syndrome (OR: 0.52; 95% CI: 0.34–0.79; P = 0.003), but not for patients with stable angina (OR: 0.71; 95% CI 0.45–1.10; P = 0.12). Long-term effects on survival were less obvious. Conclusions High-dose statin pretreatment can result in a significant reduction in PMI and MACE for patients undergoing elective PCI. The positive effect of high-dose statin pretreatment on PMI and MACE is significant for statin-naïve patients and patients with prior treatment. The positive effect of high-dose statin pretreatment on MACE is significant for patients with acute coronary syndrome. PMID:25473831
Macias, B R; Lima, F; Swift, J M; Shirazi-Fard, Y; Greene, E S; Allen, M R; Fluckey, J; Hogan, H A; Braby, L; Wang, Suojin; Bloomfield, S A
2016-09-01
Exploration missions to the Moon or Mars will expose astronauts to galactic cosmic radiation and low gravitational fields. Exposure to reduced weightbearing and radiation independently result in bone loss. However, no data exist regarding the skeletal consequences of combining low-dose, high-linear energy transfer (LET) radiation and partial weightbearing. We hypothesized that simulated galactic cosmic radiation would exacerbate bone loss in animals held at one-sixth body weight (G/6) without radiation exposure. Female BALB/cByJ four-month-old mice were randomly assigned to one of the following treatment groups: 1 gravity (1G) control; 1G with radiation; G/6 control; and G/6 with radiation. Mice were exposed to either silicon-28 or X-ray radiation. (28)Si radiation (300 MeV/nucleon) was administered at acute doses of 0 (sham), 0.17 and 0.5 Gy, or in three fractionated doses of 0.17 Gy each over seven days. X radiation (250 kV) was administered at acute doses of 0 (sham), 0.17, 0.5 and 1 Gy, or in three fractionated doses of 0.33 Gy each over 14 days. Bones were harvested 21 days after the first exposure. Acute 1 Gy X-ray irradiation during G/6, and acute or fractionated 0.5 Gy (28)Si irradiation during 1G resulted in significantly lower cancellous mass [percentage bone volume/total volume (%BV/TV), by microcomputed tomography]. In addition, G/6 significantly reduced %BV/TV compared to 1G controls. When acute X-ray irradiation was combined with G/6, distal femur %BV/TV was significantly lower compared to G/6 control. Fractionated X-ray irradiation during G/6 protected against radiation-induced losses in %BV/TV and trabecular number, while fractionated (28)Si irradiation during 1G exacerbated the effects compared to single-dose exposure. Impaired bone formation capacity, measured by percentage mineralizing surface, can partially explain the lower cortical bone thickness. Moreover, both partial weightbearing and (28)Si-ion exposure contribute to a higher proportion of sclerostin-positive osteocytes in cortical bone. Taken together, these data suggest that partial weightbearing and low-dose, high-LET radiation negatively impact maintenance of bone mass by lowering bone formation and increasing bone resorption. The impaired bone formation response is associated with sclerostin-induced suppression of Wnt signaling. Therefore, exposure to low-dose, high-LET radiation during long-duration spaceflight missions may reduce bone formation capacity, decrease cancellous bone mass and increase bone resorption. Future countermeasure strategies should aim to restore mechanical loads on bone to those experienced in one gravity. Moreover, low-doses of high-LET radiation during long-duration spaceflight should be limited or countermeasure strategies employed to mitigate bone loss.
Wentz, A L; Jimenez, T B; Dixon, R M; Aurora, S K; Gold, M
2008-04-01
The objective of the present study was to explore the clinical efficacy and tolerability of GW406381, a cyclooxygenase-2 (COX-2) inhibitor with relatively high CNS penetration, in acute migraine. This was a double-blind, single-dose study of GW406381 compared with placebo and naproxen sodium compared with placebo (protocol number CXA20008). Three hundred and thirty-seven subjects were randomized 1:1:1 to GW406381 (70 mg), naproxen sodium (825 mg), or placebo for the treatment of one migraine headache of moderate or severe intensity in a potential 8-week period. The primary end-point was the proportion of subjects with headache relief [reduction in headache severity score from pre-dose 2 (moderate) or 3 (severe) to 0 (no pain) or 1 (mild)] at 2 h post-dose for GW406381 compared with placebo. Significantly higher proportions of subjects treated with GW406381 (50%, P = 0.032) or naproxen sodium (56%, P = 0.005) than with placebo (35%) reported headache relief at 2 h post-dose. Additional significant benefits were observed on many secondary outcomes, including proportions of subjects pain-free, for both GW406381 and naproxen sodium treatment compared with placebo. Both active treatments were well tolerated. Single-dose GW406381 (70 mg) and naproxen sodium (825 mg) were effective and well tolerated in the treatment of acute migraine.
The dosimetric effects of photon energy on the quality of prostate volumetric modulated arc therapy.
Mattes, Malcolm D; Tai, Cyril; Lee, Alvin; Ashamalla, Hani; Ikoro, N C
2014-01-01
Studies comparing the dosimetric effects of high- and low-energy photons to treat prostate cancer using 3-dimensional conformal and intensity modulated radiation therapy have yielded mixed results. With the advent of newer radiation delivery systems like volumetric modulated arc therapy (VMAT), the impact of changing photon energy is readdressed. Sixty-five patients treated for prostate cancer at our institution from 2011 to 2012 underwent CT simulation. A target volume encompassing the prostate and entire seminal vesicles was treated to 50.4 Gy, followed by a boost to the prostate and proximal seminal vesicles to a total dose of 81 Gy. The VMAT plans were generated for 6-MV and 10-MV photons under identical optimization conditions using the Eclipse system version 8.6 (Varian Medical Systems, Palo Alto, CA). The analytical anisotropic algorithm was used for all dose calculations. Plans were normalized such that 98% of the planning target volume (PTV) received 100% of the prescribed dose. Dose-volumetric data from the treatment planning system was recorded for both 6-MV and 10-MV plans, which were compared for both the entire cohort and subsets of patients stratified according to the anterior-posterior separation. Plans using 10-MV photons had statistically significantly lower relative integral dose (4.1%), gradient measure (4.1%), skin Dmax (16.9%), monitor units (13.0%), and bladder V(30) (3.1%) than plans using 6-MV photons (P < .05). There was no difference in rectal dose, high-dose-region bladder dose, PTV coverage, or conformity index. The benefit of 10-MV photons was more pronounced for thicker patients (anterior-posterior separation >21 cm) for most parameters, with statistically significant differences in bladder V(30), bladder V(65), integral dose, conformity index, and monitor units. The main dosimetric benefits of 10-MV as compared with 6-MV photons are seen in thicker patients, though for the entire cohort 10-MV plans resulted in a lower integral dose, gradient measure, skin Dmax, monitor units, and bladder V(30), possibly at the expense of higher rectum V(81). Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Yim, Haejun; Yang, Hyeong-Tae; Cho, Yong-Suk; Kim, Dohern; Kim, Jong-Hyun; Chun, Wook; Hur, Jun
2014-12-01
This study is a phase 1 and 2 clinical trial for investigating the safety profile, effective treatment dose and effectiveness of the newly developed thermosensitive hydrogel-type cultured epidermal allograft. For phase 1, the keratinocytes were divided into 3 groups as follows, with 5 patients in each group: (1) low-dose group (6.7×10(6)/1.5mL), (2) medium-dose group (2×10(7)/1.5mL), and (3) high-dose group (6.0×10(7)/1.5mL). The second phase of the trial proceeded with 10 cases after choosing the most effective dose based on the analysis of the first phase. When comparing re-epithelialization time, medium- and high-dose group showed significantly shorter re-epithelialization time than low-dose group (p=0.003 and p=0.002). A total of 15 cases, 5 cases selected from phase 1 and 10 cases test in phase 2 with the medium dose, were compared with the re-epithelialization period. The re-epithelialization period was 9.6±4.0 days in the test site and 12.4±4.8 days in the control site. In the test site, re-epithelialization was 2.8±1.8 days faster than in the control site (p<0.0001). There was no significant adverse reaction in our clinical trial. In conclusion, this new type of CEAllo accelerates wound healing time and shows the safety. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Ramadan, Gamal; El-Beih, Nadia M; Talaat, Roba M; Abd El-Ghffar, Eman A
2017-02-01
Recently, there has been an increasing interest in tea (Camellia sinensis) as a protective agent against inflammatory diseases. Here, we evaluated/compared the anti-inflammatory activity of two different doses (0.5 and 1.0 g/kg body weight) of green tea aqueous extract (GTE, rich in catechins) and black tea aqueous extract (BTE, rich in theaflavins and thearubigins) in rat adjuvant-induced arthritis (AIA). Adjuvant-induced arthritis rat model received orally/daily distilled water as vehicle, indomethacin (1.0 mg/kg body weight; a non-steroidal/anti-inflammatory drug), or tea aqueous extracts (for 28 or 14 consecutive days starting from day 0 or 14 of arthritis induction, respectively). The present study showed that only the high dose of GTE (from day 0) significantly alleviated (P < 0.05-0.001) all complications shown in arthritic rats, including synovial joint inflammation, elevation in erythrocyte sedimentation rate, blood leukocytosis (due to lymphocytosis and neutrocytosis), and changes in weight/cellularity of lymphoid organs. The anti-arthritic activity of the high dose of GTE (from day 0) was comparable (P > 0.05) with that of indomethacin (12.9-53.8 vs. 9.5-48.4%, respectively) and mediated by significantly decreasing and down-regulating (P < 0.001) the systemic production of pro-inflammatory cytokines and the expression of chemokine receptor-5 in synovial tissues, respectively. Moreover, the anti-arthritic activity of tea aqueous extracts was in the following order: high dose of GTE > low dose of GTE ≥ high dose of BTE > low dose of BTE. The present study proved the anti-inflammatory activity of GTE over BTE and equal to that of indomethacin in AIA rat model. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Grimnes, G; Emaus, N; Cashman, K D; Jorde, R
2017-07-01
Observational studies have suggested positive associations between serum 25-hydroxyvitamin D (25(OH)D) levels and muscular strength, balance and quality of life. Our aim was to examine whether high-dose vitamin D supplementation would improve these measures as compared to standard-dose vitamin D, as well as the possible muscular effects of single nucleotide polymorphisms (SNPs) in genes encoding vitamin D-related enzymes. A 12-month randomized, double-blind, controlled trial where the participants received daily elemental calcium (1000 mg) plus vitamin D 3 (800 IU). In addition, the participants were randomized to receive either capsules with vitamin D 3 (20 000 IU) or matching placebos to be taken twice a week. A total of 297 postmenopausal women with osteopenia or osteoporosis. Muscle strength (handgrip and knee extensor strength), balance (tandem test) and quality of life (EQ-5D) were measured at baseline and after 12 months. The subjects were genotyped for SNPs related to vitamin D metabolism. Of the 297 included women, 275 completed the study. Mean serum 25(OH)D levels dramatically increased in the high-dose group (from 64.7 to 164.1 nmol/L; P<.01), while a more moderate increased was observed in the standard-dose group (from 64.1 to 81.8 nmol/L; P<.01). There was no significant difference between the groups in change in muscular strength, balance or quality of life over the intervention period. Polymorphisms in rs3829251 (located in the 7-dehydrocholesterol reductase gene) were associated with muscle strength and treatment effects. One-year treatment with high-dose vitamin D had no effect on muscular strength, balance or quality of life in postmenopausal women with osteopenia or osteoporosis as compared to standard dose. The association between rs3829251 and muscle strength needs confirmation in other populations. © 2017 John Wiley & Sons Ltd.
Apu, Apurba Sarker; Bhuyan, Shakhawat Hossan; Matin, Maima; Hossain, Faruq; Khatun, Farjana; Taiab, Abu; Jamaluddin
2013-01-01
The present study was undertaken to evaluate the possible analgesic, neuropharmacological, anti-diarrheal, and cytotoxic activities of the ethanol extract of leaves of Solanum sisymbriifolium Lam. (Family: Solanaceae). The analgesic activity was measured by acetic acid-induced writhing inhibition test. The neuropharmacological activities were evaluated using hole cross, hole board, and elevated plus-maze test and the anti-diarrheal activity was assessed using castor oil-induced diarrhea inhibition method. Brine shrimp lethality bioassay was carried out for assessing the cytotoxicity of the ethanol extract of the leaves. Except cytotoxic activity, all the tests were conducted on mice. The extract at oral doses of 200 and 400 mg/kg body weight showed highly significant (p<0.001) decrease in number of writhing, 52.1±0.66 and 4.4±0.64 compared with the control (78.6±0.29) with the percentage of inhibitions of writhing response were found to be 33.72% and 94.40%, respectively. Compare with the control, the extract at both doses showed significant sedative effect in hole cross test. In hole board test, the extract exhibited highly significant (p<0.001) anxiolytic activity at dose of (200 mg/kg), while the same activity was observed at dose of 400 mg/kg in elevated plus-maze test. The extract showed highly significant (p<0.001) anti-diarrheal activity in a dose-dependent manner. With the extract, significant lethality to brine shrimp was found with LC50 value of 61.66±0.9 μg/ml, which was comparable with the positive control (LC50: 11.89±0.8 µg/ml). The results from the present studies support the traditional uses of this plant part and could form the basis of further investigation including compound isolation.
NASA Technical Reports Server (NTRS)
Tran, Luan Hoang; Alwood, Joshua; Kumar, Akhilesh; Limoli, C. L.; Globus, Ruth
2012-01-01
Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week old C57BL6/J mice were exposed to high LET (56 Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3 - 4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 micron pixel size) and marrow cell redox assessed using membrane permeable, free radical sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT PCR. Interestingly, 3 - 4 days post exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF FM Diacetate or CM H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower(24%) relative to sham irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down regulate iNOS by 0.54 - 0.58 fold. Thus, both low and high doses of heavy ion irradiation cause time dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.
Isotonic Regression Based-Method in Quantitative High-Throughput Screenings for Genotoxicity
Fujii, Yosuke; Narita, Takeo; Tice, Raymond Richard; Takeda, Shunich
2015-01-01
Quantitative high-throughput screenings (qHTSs) for genotoxicity are conducted as part of comprehensive toxicology screening projects. The most widely used method is to compare the dose-response data of a wild-type and DNA repair gene knockout mutants, using model-fitting to the Hill equation (HE). However, this method performs poorly when the observed viability does not fit the equation well, as frequently happens in qHTS. More capable methods must be developed for qHTS where large data variations are unavoidable. In this study, we applied an isotonic regression (IR) method and compared its performance with HE under multiple data conditions. When dose-response data were suitable to draw HE curves with upper and lower asymptotes and experimental random errors were small, HE was better than IR, but when random errors were big, there was no difference between HE and IR. However, when the drawn curves did not have two asymptotes, IR showed better performance (p < 0.05, exact paired Wilcoxon test) with higher specificity (65% in HE vs. 96% in IR). In summary, IR performed similarly to HE when dose-response data were optimal, whereas IR clearly performed better in suboptimal conditions. These findings indicate that IR would be useful in qHTS for comparing dose-response data. PMID:26673567
Zemplényi, A T; Kaló, Z; Kovács, G; Farkas, R; Beöthe, T; Bányai, D; Sebestyén, Z; Endrei, D; Boncz, I; Mangel, L
2018-01-01
The aim of our analysis was to compare the cost-effectiveness of high-dose intensity-modulated radiation therapy (IMRT) and hypofractionated intensity-modulated radiation therapy (HF-IMRT) versus conventional dose three-dimensional radiation therapy (3DCRT) for the treatment of localised prostate cancer. A Markov model was constructed to calculate the incremental quality-adjusted life years and costs. Transition probabilities, adverse events and utilities were derived from relevant systematic reviews. Microcosting in a large university hospital was applied to calculate cost vectors. The expected mean lifetime cost of patients undergoing 3DCRT, IMRT and HF-IMRT were 7,160 euros, 6,831 euros and 6,019 euros respectively. The expected quality-adjusted life years (QALYs) were 5.753 for 3DCRT, 5.956 for IMRT and 5.957 for HF-IMRT. Compared to 3DCRT, both IMRT and HF-IMRT resulted in more health gains at a lower cost. It can be concluded that high-dose IMRT is not only cost-effective compared to the conventional dose 3DCRT but, when used with a hypofractionation scheme, it has great cost-saving potential for the public payer and may improve access to radiation therapy for patients. © 2016 John Wiley & Sons Ltd.
Howlett, Christina; Snedecor, Sonya J; Landsburg, Daniel J; Svoboda, Jakub; Chong, Elise A; Schuster, Stephen J; Nasta, Sunita Dwivedy; Feldman, Tatyana; Rago, Allison; Walsh, Kristy M; Weber, Scott; Goy, Andre; Mato, Anthony
2015-08-01
'Double-hit lymphomas' (DHL), defined by concurrent MYC and BCL2 (or, alternatively, BCL6) rearrangements, have a very poor outcome compared to standard-risk, diffuse large B-cell lymphomas (DLBCL). Consequently, dose-intensive (DI) therapies and/or consolidation with high-dose therapy and transplant have been explored in DHL, although benefit has been debated. This meta-analysis compared survival outcomes in DHL patients receiving dose-escalated regimens [DI: R-Hyper-CVAD (rituximab, cyclophosphamide, vincristine, doxorubicin, dexamethasone) or R-CODOX-M/IVAC (rituximab, cyclophosphamide, doxorubicin, vincristine, methotrexate/ifosfamide, etoposide, high dose cytarabine); or intermediate-dose: R-EPOCH (rituximab, etoposide, doxorubicin, cyclophosphamide, vincristine, prednisone)] versus standard-dose regimens (R-CHOP; rituximab, cyclophosphamide, doxorubicin, vincristine, prednisone) in the first-line setting. Data were synthesized to estimate hazard ratios of dose-escalated treatments versus R-CHOP using a Weibull proportional hazards model within a Bayesian meta-analysis framework. Eleven studies examining 394 patients were included. Patients were treated with either front-line R-CHOP (n = 180), R-EPOCH (n = 91), or R-Hyper-CVAD/rituximab, methotrexate, cytarabine (R-M/C), R-CODOX-M/R-IVAC (DI) (n = 123). Our meta-analysis revealed that median progression-free survival (n = 350) for the R-CHOP, R-EPOCH and DI groups was 12·1, 22·2, and 18·9 months, respectively. First-line treatment with R-EPOCH significantly reduced the risk of a progression compared with R-CHOP (relative risk reduction of 34%; P = 0·032); however, overall survival (n = 374) was not significantly different across treatment approaches. A subset of patients might benefit from intensive induction with/without transplant. Further investigation into the role of transplant and novel therapy combinations is necessary. © 2015 John Wiley & Sons Ltd.
Doshi, Reena H; Eckhoff, Philip; Cheng, Alvan; Hoff, Nicole A; Mukadi, Patrick; Shidi, Calixte; Gerber, Sue; Wemakoy, Emile Okitolonda; Muyembe-Tafum, Jean-Jacques; Kominski, Gerald F; Rimoin, Anne W
2017-10-27
One of the goals of the Global Measles and Rubella Strategic Plan is the reduction in global measles mortality, with high measles vaccination coverage as one of its core components. While measles mortality has been reduced more than 79%, the disease remains a major cause of childhood vaccine preventable disease burden globally. Measles immunization requires a two-dose schedule and only countries with strong, stable immunization programs can rely on routine services to deliver the second dose. In the Democratic Republic of Congo (DRC), weak health infrastructure and lack of provision of the second dose of measles vaccine necessitates the use of supplementary immunization activities (SIAs) to administer the second dose. We modeled three vaccination strategies using an age-structured SIR (Susceptible-Infectious-Recovered) model to simulate natural measles dynamics along with the effect of immunization. We compared the cost-effectiveness of two different strategies for the second dose of Measles Containing Vaccine (MCV) to one dose of MCV through routine immunization services over a 15-year time period for a hypothetical birth cohort of 3 million children. Compared to strategy 1 (MCV1 only), strategy 2 (MCV2 by SIA) would prevent a total of 5,808,750 measles cases, 156,836 measles-related deaths and save U.S. $199 million. Compared to strategy 1, strategy 3 (MCV2 by RI) would prevent a total of 13,232,250 measles cases, 166,475 measles-related deaths and save U.S. $408 million. Vaccination recommendations should be tailored to each country, offering a framework where countries can adapt to local epidemiological and economical circumstances in the context of other health priorities. Our results reflect the synergistic effect of two doses of MCV and demonstrate that the most cost-effective approach to measles vaccination in DRC is to incorporate the second dose of MCV in the RI schedule provided that high enough coverage can be achieved. Published by Elsevier Ltd.
Wei, Yan; Zeng, Beibei; Zhang, Hua; Chen, Cheng; Wu, Yanli; Wang, Nanlan; Wu, Yanqiu; Zhao, Danqing; Zhao, Yuxi; Iqbal, Javed; Shen, Liming
2018-07-01
Long-term excessive intake of fluoride (F) could lead to chronic fluorosis. To explore the underlying molecular mechanisms, present study is designed to elucidate the effect of fluoride on proteome expression of bone in sodium fluoride (NaF)-treated SD rats. Hematoxylin and eosin (H&E) staining was used to determine the severity of osteofluorosis, and bone samples were submitted for iTRAQ analysis. The results showed that the cortical thickness and trabecular area of femur bone in medium- and high-dose groups were higher than in control group. Contrary to this, trabecular area was reduced in the low-dose group, indicating that the bone mass was increased in medium- and high-dose groups, and decreased in the low-dose group. Thirteen (13), 35, and 34 differentially expressed proteins were identified in low-, medium-, and high-dose group, respectively. The medium- and high-dose groups shared a more similar protein expression pattern. These proteins were mainly associated with collagen metabolism, proteoglycans (PGs), matrix metalloproteinases (MMPs), etc. The results suggested that the effect of NaF on SD rats is in a dose-dependent manner. Some key proteins found here may be involved in affecting the bone tissues and bone marrow or muscle, and account for the complex pathology and clinical symptoms of fluorosis. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Zimmer, J. Paul; Lewis, Sherry M.; Moyer, Jerry L.
1993-01-01
Gavage, water bottle, and diet incorporation are 3 dosing methods used orally to administer test compounds to rodents. These 3 methods were compared in mice to determine which represented the most quantitative delivery system. For dietary incorporation, a high-moisture bolus form of NIH-31 rodent meal was developed using hydroxypropyl methylcellulose as an autoclave-stable binding agent. A high-moisture bolus were selected to increase the acceptability of the dosed diet and to promote quantitative consumption through reduced wastage. The test compound used was D-xylose, a pentose sugar that may be quantitatively detected, colorimetrically, in urine following oral dosing. Six male and 6 female B6D2FI mice were placed in metabolism cages and dosed with a known quantity of D-xylose by each of the 3 methods. Urine was collected before and after each method of administration and analysed for total D-xylose; the per cent recovery was based upon the amount of D-xylose consumed. Quantitative consumption was apparently greatest for water bottle dosing with an average recovery of 56.0% of the original D-xylose dose. High-moisture bolus incorporation ranked second with 50.0% D-xylose recovery, and gavage was third with 41.0% D-xylose recovery.
NASA Astrophysics Data System (ADS)
Sahbaee, Pooyan; Abadi, Ehsan; Sanders, Jeremiah; Becchetti, Marc; Zhang, Yakun; Agasthya, Greeshma; Segars, Paul; Samei, Ehsan
2016-03-01
The purpose of this study was to substantiate the interdependency of image quality, radiation dose, and contrast material dose in CT towards the patient-specific optimization of the imaging protocols. The study deployed two phantom platforms. First, a variable sized phantom containing an iodinated insert was imaged on a representative CT scanner at multiple CTDI values. The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast to noise ratio (CNR), was calculated for different iodine-concentration levels. Second, the analysis was extended to a recently developed suit of 58 virtual human models (5D-XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was "imaged" using a CT simulation platform. 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The Sensitivity of Ratio (SR), defined as ratio of change in iodine-concentration versus dose to yield a constant change in CNR was calculated and compared at high and low radiation dose for both phantom platforms. The results show that sensitivity of CNR to iodine concentration is larger at high radiation dose (up to 73%). The SR results were highly affected by radiation dose metric; CTDI or organ dose. Furthermore, results showed that the presence of contrast material could have a profound impact on optimization results (up to 45%).
Mandapaka, A K; Ghebremedhin, A; Patyal, B; Marinelli, Marco; Prestopino, G; Verona, C; Verona-Rinati, G
2013-12-01
To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams. The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up∕stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated. A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy∕min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters. The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.
Warmington, Leighton L; Gopishankar, N; Broadhurst, John H; Watanabe, Yoichi
2016-12-01
To investigate the feasibility of three-dimensional (3D) dose measurements near thin high-Z materials placed in a water-like medium by using a polymer gel dosimeter (PGD) when the medium was irradiated with high energy photon beams. PGD is potentially a useful tool for this application because it can record the dose around a small object made of a high-Z material in a continuous 3D medium. In this study, the authors manufactured a methacrylic acid-based normoxic PGD, nMAG. Two 0.5 mm thick lead foils (1 × 1 cm) were placed in foil supports with 0.7 cm separation in a 1000 ml polystyrene container filled with nMAG. The authors used two foil configurations, i.e., orthogonal and parallel. In the orthogonal configuration, two foils were placed in the direction orthogonal to the beam axis. The parallel configuration had two foils arranged in parallel to the beam axis. The phantom was irradiated with an 18 MV photon beam of 5 × 5 cm field size. It was imaged with a three-Tesla (3 T) magnetic resonance imaging (MRI) scanned using the Car-Purcell-Meiboom-Gill pulse sequence. The spin-spin relaxation time (R2) to-dose calibration data were obtained by using small vials filled with nMAG and exposing to known doses. The DOSXYZnrc Monte Carlo (MC) code was used to get the expected dose distributions. More than 35 × 10 6 of histories were simulated so that the average error was less than 1%. An in-house matlab-based software was used to obtain the dose distributions from the measured R2 data as well as to compare the measurements and the MC predictions. The dose change due to the presence of the foils was studied by comparing the dose distributions with and without foils (or the reference). For the orthogonal configuration, the measured dose along the beam axis showed an increase in the upstream side of the first foil, between the foils, and on the downstream side of the second foil. The range of increased dose area was 1.1 cm in the upstream of the first foil. However, in the downstream of the second foil, it was 0.2 cm, beyond which the dose fell below the reference dose by 10%. The dose profile between the foils showed a well-like shape with the minimum dose still larger than the reference dose by 1.8%. The minimum dose point was closer to the first foil than to the second foil. For the parallel configuration, the dose between foils was the largest at the center. The increased dose area opposite to the gap between foils extended outward to 1 cm. The spatial dose distributions of PGD and MC showed the same geometrical patterns except for the points inside the foils for both orthogonal and parallel foil arrangements. The authors demonstrated that the nMAG PGD with MRI could be used to measure the 3D dosimetric structures at the mm-scale in the vicinity of the foil. The current study provided more accurate 3D spatial dose distribution than the previous studies. Furthermore, the measurements were validated by the MC simulation.
Kaden, Jürgen; May, Gottfried; Völp, Andreas; Wesslau, Claus
2009-01-01
In organ grafts donor-specific sensitization is initiated immediately after revascularization. Therefore, in 1990 we introduced the intra-operative single high-dose ATG-Fresenius (ATG-F) induction in addition to standard triple drug therapy (TDT) consisting of steroids, azathioprine and cyclosporin. A total of 778 first renal transplantations from deceased donors, performed between 1987 and 1998, were included in this evaluation. This retrospective analysis of clinic records and electronic databases presents data of all recipients of first kidney grafts who received two different ATG-F inductions (1(st) group: 9 mg/kg body weight as single high-dose intra-operatively, n=484; 2(nd) group: 3 mg/kg body weight on 7 or 8 consecutive days as multiple-dose starting also intra-operatively, n=78) and standard TDT alone (3(rd) group: TDT alone, n=216). The 10-year patient survival rates were 72.6+/-2.6% (TDT + ATG-F single high-dose), 79.5+/-5.1% (TDT + ATG-F multiple-dose) and 67.2+/-3.7%% (TDT alone; Kaplan-Meier estimates with standard errors; ATG-F vs TDT alone, p=0.001). The 10-year graft survival rates with censoring of patients that died with a functioning graft were 73.8+/-2.4%, 57.7+/-5.8% and 58.4+/-3.6% (Kaplan-Meier estimates with standard errors; 1(st) vs 2(nd )and 3(rd) group, respectively, p<0.001) and the 10-year graft survival rates with patient death counted as graft failure were 58.3+/-2.7%, 55.7+/-5.8% and 48.2+/-3.5% (Kaplan-Meier estimates with standard errors; ATG-F single high-dose vs TDT, p=0.023). In pre-sensitized recipients there were also significant differences in favour of ATG-F, more notably in the single high-dose ATG-F induction. A total of 69% of the patients in the two cohorts receiving ATG-F did not experience any transplant rejections compared to 56% in patients undergoing TDT alone (p=0.018). The incidence of infectious complications was comparable across all groups. According to evidence obtained from the routine documentation of 778 renal transplantations, ATG-F induction therapy administered as a part of immunosuppressive therapy significantly improves patient survival and reduces the risk of graft failure and transplant rejections.
Schüler, Emil; Eriksson, Kjell; Hynning, Elin; Hancock, Steven L; Hiniker, Susan M; Bazalova-Carter, Magdalena; Wong, Tony; Le, Quynh-Thu; Loo, Billy W; Maxim, Peter G
2017-06-01
The aim of this study was to evaluate the performance of very high-energy electron beams (VHEE) in comparison to clinically derived treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PPBS) technology. We developed a custom optimization script that could be applied automatically across modalities to eliminate operator bias during IMRT optimization. Four clinical cases were selected (prostate cancer, lung cancer, pediatric brain tumor, and head and neck cancer (HNC)). The VHEE beams were calculated in the EGSnrc/DOSXYZnrc Monte Carlo code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PPBS were optimized in a research version of RayStation using an in-house developed script to minimize operator bias between the different techniques. The in-house developed script generated similar or superior plans to the clinically used plans. In the comparisons between the modalities, the integral dose was lowest for the PPBS-generated plans in all cases. For the prostate case, the 200 MeV VHEE plan showed reduced integral dose and reduced organ at risk (OAR) dose compared to the VMAT plan. For all other cases, both the 100 and the 200 MeV VHEE plans were superior to the VMAT plans, and the VHEE plans showed better conformity and lower spinal cord dose in the pediatric brain case and lower brain stem dose in the HNC case when compared to the PPBS plan. The automated optimization developed in this study generated similar or superior plans as compared to the clinically used plan and represents an unbiased approach to compare treatment plans generated for different modalities. In the present study, we also show that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases, and VHEE plans can even achieve reductions in OAR doses compared to PPBS plans for shallow targets. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses are achieved. On the whole, VHEE was intermediate between photon VMAT and PPBS for OAR sparing. © 2017 American Association of Physicists in Medicine.
Subchronic effects of methylmercury on plasma and organ biochemistries in great egret nestlings
Hoffman, D.J.; Spalding, M.G.; Frederick, P.C.
2005-01-01
In recent years, high concentrations of mercury have been found in wading birds in Florida, USA. Great egret (Ardea alba) chicks (2 weeks old) were dosed orally daily with the equivalent of 0, 0.5, or 5 ug/g Hg as methylmercury chloride in the diet for up to 12 weeks. Weakness of the legs or paralysis occurred in all high-dosed birds. Geometric mean blood Hg concentrations were 0.17, 10.3, and 78.5 ug/g (wet wt), respectively. Mercury concentrations for organs (ug/g wet wt), including brain (0.22, 3.4, and 35, respectively), liver (0.34, 15.1, 138, respectively), and kidney (0.28, 8.1, and 120, respectively), increased in a dose-dependent manner. Total glutathione (GSH) peroxidase activity was significantly lower in the plasma, brain, liver, and kidney of the high-dosed group. Plasma aspartate aminotransferase activity increased with mercury treatment, whereas lactate dehydrogenase activity decreased. Four other plasma chemistries were decreased significantly in the high-dosed group and included uric acid, total protein, albumin, and inorganic phosphorus. Lipid peroxidation increased in liver (low and high dose) and brain (high dose). Tissue changes in concentrations of reduced thiols included decreased total thiols and protein-bound thiols in liver, decreased protein-bound thiols in kidney, and increased GSH in kidney and brain. Activities of GSH S-transferase and oxidized glutathione reductase increased in liver. In kidney, GSH S-transferase and glucose-6-phosphate dehydrogenase activities increased with mercury dose. These findings, including apparent compensatory changes, are compared to other Hg studies where oxidative stress was reported in egrets, herons, and diving ducks in the field and mallards in the laboratory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Universities Space Research Association; Chappell, Lori J.; Whalen, Mary K.
2010-12-15
We developed a mathematical method to analyze flow cytometry data to describe the kinetics of {gamma}H2AX and pATF2 phosphorylations ensuing various qualities of low dose radiation in normal human fibroblast cells. Previously reported flow cytometry kinetic results for these DSB repair phospho-proteins revealed that distributions of intensity were highly skewed, severely limiting the detection of differences in the very low dose range. Distributional analysis reveals significant differences between control and low dose samples when distributions are compared using the Kolmogorov-Smirnov test. Radiation quality differences are found in the distribution shapes and when a nonlinear model is used to relate dosemore » and time to the decay of the mean ratio of phosphoprotein intensities of irradiated samples to controls. We analyzed cell cycle phase and radiation quality dependent characteristic repair times and residual phospho-protein levels with these methods. Characteristic repair times for {gamma}H2AX were higher following Fe nuclei as compared to X-rays in G1 cells (4.5 {+-} 0.46 h vs 3.26 {+-} 0.76 h, respectively), and in S/G2 cells (5.51 {+-} 2.94 h vs 2.87 {+-} 0.45 h, respectively). The RBE in G1 cells for Fe nuclei relative to X-rays for {gamma}H2AX was 2.05 {+-} 0.61 and 5.02 {+-} 3.47, at 2 h and 24-h postirradiation, respectively. For pATF2, a saturation effect is observed with reduced expression at high doses, especially for Fe nuclei, with much slower characteristic repair times (>7 h) compared to X-rays. RBEs for pATF2 were 0.66 {+-} 0.13 and 1.66 {+-} 0.46 at 2 h and 24 h, respectively. Significant differences in {gamma}H2AX and pATF2 levels comparing irradiated samples to control were noted even at the lowest dose analyzed (0.05 Gy) using these methods of analysis. These results reveal that mathematical models can be applied to flow cytometry data to uncover important and subtle differences following exposure to various qualities of low dose radiation.« less
Lee, Jin; Lee, Hae-In; Seo, Kown-Il; Cho, Hyun Wook; Kim, Myung-Joo; Park, Eun-Mi; Lee, Mi-Kyung
2014-07-01
Ursolic acid (UA) is a pentacyclic triterpenoid compound that naturally occurs in fruits, leaves and flowers of medicinal herbs. This study investigated the dose-response efficacy of UA (0.01 and 0.05%) on glucose metabolism, the polyol pathway and dyslipidemia in streptozotocin/nicotinamide-induced diabetic mice. Supplement with both UA doses reduced fasting blood glucose and plasma triglyceride levels in non-obese type 2 diabetic mice. High-dose UA significantly lowered plasma free fatty acid, total cholesterol and VLDL-cholesterol levels compared with the diabetic control mice, while LDL-cholesterol levels were reduced with both doses. UA supplement effectively decreased hepatic glucose-6-phosphatase activity and increased glucokinase activity, the glucokinase/glucose-6-phosphatase ratio, GLUT2 mRNA levels and glycogen content compared with the diabetic control mice. UA supplement attenuated hyperglycemia-induced renal hypertrophy and histological changes. Renal aldose reductase activity was higher, whereas sorbitol dehydrogenase activity was lower in the diabetic control group than in the non-diabetic group. However, UA supplement reversed the biochemical changes in polyol pathway to normal values. These results demonstrated that low-dose UA had preventive potency for diabetic renal complications, which could be mediated by changes in hepatic glucose metabolism and the renal polyol pathway. High-dose UA was more effective anti-dyslipidemia therapy in non-obese type 2 diabetic mice.
Yang, Yue; Wei, Ri-bao; Zheng, Xiao-yong; Qiu, Qiang; Cui, Shao-yuan; Yin, Zhong; Shi, Suo-zhu; Chen, Xiang-mei
2014-03-01
To observe the effect of Compound Shenhua Tablet (, SHT) on the sodium-potassium- exchanging adenosinetriphosphatase (Na(+)-K(+)-ATPase) in the renal tubular epithelial cells of rats with acute ischemic reperfusion and to investigate the mechanisms underlying the effects of SHT on renal ischemic reperfusion injury (RIRI). Fifty male Wistar rats were randomly divided into the sham surgery group, model group, astragaloside group [150 mg/(kg·d)], SHT low-dose group [1.5 g/(kg·d)] and SHT high-dose group [3.0 g/(kg·d)], with 10 rats in each group. After 1 week of continuous intragastric drug administration, surgery was performed to establish the model. At either 24 or 72 h after the surgery, 5 rats in each group were sacrificed, blood biochemistry, renal pathology, immunoblot and immunohistochemical examinations were performed, and double immunofluorescence staining was observed under a laser confocal microscope. Compared with the sham surgery group, the serum creatinine (SCr) and blood urea nitrogen (BUN) levels were significantly increased, Na(+)-K(+)-ATPase protein level was decreased, and kidney injury molecule-1 (KIM-1) protein level was increased in the model group after the surgery (P<0.01 or P<0.05). Compared with the model group, the SCr, BUN, pathological scores, Na(+)-K(+)-ATPase, and the KIM-1 protein level of the three treatment groups were significantly improved at 72 h after the surgery (P<0.05 or P<0.01). And the SCr, BUN of the SHT low- and high-dose groups, and the pathological scores of the SHT high-dose group were significantly lower than those of the astragaloside group (P<0.05). The localizations of Na(+)-K(+)-ATPase and megalin of the model group were disrupted, with the distribution areas overlapping with each other and alternately arranged. The severity of the disruption was slightly milder in three treatment groups compared with that of the model group. The results of immunofluorescence staining showed that the SHT high-dose group had a superior effect as compared with the astragaloside group and the SHT low-dose group. The SHT effectively alleviated RIRI caused by ischemic reperfusion, promoted the recovery of the polarity of renal tubular epithelial cells, and protected the renal tubules. The therapeutic effects of SHT were superior to those of astragaloside as a single agent.
Kushioka, Junichi; Yamashita, Tomoya; Okuda, Shinya; Maeno, Takafumi; Matsumoto, Tomiya; Yamasaki, Ryoji; Iwasaki, Motoki
2017-03-01
OBJECTIVE Tranexamic acid (TXA), a synthetic antifibrinolytic drug, has been reported to reduce blood loss in orthopedic surgery, but there have been few reports of its use in spine surgery. Previous studies included limitations in terms of different TXA dose regimens, different levels and numbers of fused segments, and different surgical techniques. Therefore, the authors decided to strictly limit TXA dose regimens, surgical techniques, and fused segments in this study. There have been no reports of using TXA for prevention of intraoperative and postoperative blood loss in posterior lumbar interbody fusion (PLIF). The purpose of the study was to evaluate the efficacy of high-dose TXA in reducing blood loss and its safety during single-level PLIF. METHODS The study was a nonrandomized, case-controlled trial. Sixty consecutive patients underwent single-level PLIF at a single institution. The first 30 patients did not receive TXA. The next 30 patients received 2000 mg of intravenous TXA 15 minutes before the skin incision was performed and received the same dose again 16 hours after the surgery. Intra- and postoperative blood loss was compared between the groups. RESULTS There were no statistically significant differences in preoperative parameters of age, sex, body mass index, preoperative diagnosis, or operating time. The TXA group experienced significantly less intraoperative blood loss (mean 253 ml) compared with the control group (mean 415 ml; p < 0.01). The TXA group also had significantly less postoperative blood loss over 40 hours (mean 321 ml) compared with the control group (mean 668 ml; p < 0.01). Total blood loss in the TXA group (mean 574 ml) was significantly lower than in the control group (mean 1080 ml; p < 0.01). From 2 hours to 40 hours, postoperative blood loss in the TXA group was consistently significantly lower. There were no perioperative complications, including thromboembolic events. CONCLUSIONS High-dose TXA significantly reduced both intra- and postoperative blood loss without causing any complications during or after single-level PLIF.
Feng, Guang-Kui; Ma, Xian-Jun; Chen, Yin-Yi; Bian, Guang-Rong; Yang, Chao; Gu, Bao-Dong
2018-01-01
Chailong Jieyu Pill (CJP) is composed of Radix Bupleuri, Radix Scutellariae, Rhizoma Pinelliae Preparata, Radix Codonopsis, Radix Glycyrrhizae preparata , keel, Concha Ostreae, Concha Margaritifera Usta, Rhizoma Zingiberis Recens , and Fructus Jujubae . CJP has shown good clinical effects on improving anxiety disorders. However, as the mechanism underlying such benefits remains unclear, the aim of this study was to investigate the mechanism of action for CJP on anxiety-related behaviors in a rat model of anxiety disorder. After establishing a rat model of anxiety disorder using uncertain empty bottle stimulation, rats were divided into control, model, citalopram, low-dose CJP, and high-dose CJP groups. After 1 month of administration, effects of treatments on rat appearance, body weight, and open-field test scores were observed. In addition, hippocampal monoamine neurotransmitter (5-hydroxytryptamine, dopamine, and norepinephrine) contents were measured with an enzyme-linked immunosorbent assay, and mRNA expression of mineralocorticoid receptor (MR) and glucocorticoid receptor (GR) were measured with reverse transcription-polymerase chain reaction. CJP increased rat weight, and this effect was increased in the high-dose CJP group compared with the citalopram group ( P < 0.05). CJP also elevated open-field test scores compared with the citalopram group ( P < 0.05). While CJP decreased monoamine neurotransmitter contents in rat hippocampus, the regulatory effect of CJP on 5-hydroxytryptamine was reduced compared with citalopram ( P < 0.01). CJP upregulated GR mRNA expression in both low-dose ( P < 0.05) and high-dose ( P < 0.01) CJP groups, but only the latter significantly downregulated MR mRNA expression and showed enhanced effects compared with citalopram ( P < 0.05). Thus, CJP likely exerted its significant antianxiety effect by diminishing monoamine neurotransmitters and regulating mRNA expression of MR and GR in the hippocampus of our rat model of anxiety disorder.
Uysal, Erdal
2017-01-01
Purpose Postoperative intraperitoneal adhesions (PIAs) are one of the most important problems surgeons have to face after laparotomies. In this study, we aimed to evaluate the effectiveness of local application of botulinum toxin type A (BoNT-A) in various dosages on the prevention of intra-abdominal adhesions in rats with experimental intra-abdominal adhesions. Methods Forty Wistar Albino female rats were randomly separated into 4 groups. The 4 groups were determined as follows: Control (group 1, n = 10); Sham (group 2, n = 10); 10-µg/kg low-dose BoNT-A (group 3, n = 10) and 30-µg/kg high-dose BoNT-A (group 4, n = 10). Subserosal injuries were created on the caecum of all rats. Laparotomy was performed on the fifth day. Adhesion scores, histopathological examination, and E-cadherin expression levels were evaluated. Results General adhesion scores for groups 1 and 2 were determined to be significantly high when compared to group 4 (P < 0.001). A significant difference was also determined between groups 3 and 4 in terms of general adhesion scores (P < 0.05). In pair comparisons, a significant decrease in high-dose BoNT-A group (group 4) when compared to groups 1 and 2 in terms of neovascularization, fibroblast density, collagen deposition and inflammatory cell count was determined (P < 0.05). Conclusion A significant decrease was observed only in postoperative PIAs in the high-dose BoNT-A group between all 4 rat-groups with experimentally created postoperative PIAs. In this study, high-dose BoNT-A is determined to be an effective agent in preventing postoperative PIAs. PMID:28706891
Cost-Effectiveness and Public Health Effect of Influenza Vaccine Strategies for U.S. Elderly Adults.
Raviotta, Jonathan M; Smith, Kenneth J; DePasse, Jay; Brown, Shawn T; Shim, Eunha; Nowalk, Mary Patricia; Zimmerman, Richard K
2016-10-01
To compare the cost-effectiveness of four influenza vaccines available in the United States for persons aged 65 and older: trivalent inactivated influenza vaccine (IIV3), quadrivalent inactivated influenza vaccine (IIV4), a more-expensive high-dose IIV3, and a newly approved adjuvanted IIV3. Cost-effectiveness analysis using a Markov model and sensitivity analyses. A hypothetical influenza vaccination season modeled according to possible U.S. influenza vaccination policies. Hypothetical cohort of individuals aged 65 and older in the United States. Cost-effectiveness and public health benefits of available influenza vaccination strategies in U.S. elderly adults. IIV3 cost $3,690 per quality-adjusted life year (QALY) gained, IIV4 cost $20,939 more than IIV3 per QALY gained, and high-dose IIV3 cost $31,214 more per QALY than IIV4. The model projected 83,775 fewer influenza cases and 980 fewer deaths with high-dose IIV3 than with the next most-effective vaccine: IIV4. In a probabilistic sensitivity analysis, high-dose IIV3 was the favored strategy if willingness to pay is $25,000 or more per QALY gained. Adjuvanted IIV3 cost-effectiveness depends on its price and effectiveness (neither yet determined in the United States) but could be favored if its relative effectiveness is 15% greater than that of IIV3. From economic and public health standpoints, high-dose IIV3 for adults aged 65 years and older is likely to be favored over the other vaccines, based on currently available data. The cost-effectiveness of adjuvanted IIV3 should be reviewed after its effectiveness has been compared with that of other vaccines and its U.S. price is established. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.
da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho
2015-10-01
The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.
TU-FG-201-06: Remote Dosimetric Auditing for Clinical Trials Using EPID Dosimetry: A Pilot Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miri, N; Legge, K; Greer, P
2016-06-15
Purpose: To perform a pilot study for remote dosimetric credentialing of intensity modulated radiation therapy (IMRT) based clinical trials. The study introduces a novel, time efficient and inexpensive dosimetry audit method for multi-center credentialing. The method employs electronic portal imaging device (EPID) to reconstruct delivered dose inside a virtual flat/cylindrical water phantom. Methods: Five centers, including different accelerator types and treatment planning systems (TPS), were asked to download two CT data sets of a Head and Neck (H&N) and Postprostatectomy (P-P) patients to produce benchmark plans. These were then transferred to virtual flat and cylindrical phantom data sets that weremore » also provided. In-air EPID images of the plans were then acquired, and the data sent to the central site for analysis. At the central site, these were converted to DICOM format, all images were used to reconstruct 2D and 3D dose distributions inside respectively the flat and cylindrical phantoms using inhouse EPID to dose conversion software. 2D dose was calculated for individual fields and 3D dose for the combined fields. The results were compared to corresponding TPS doses. Three gamma criteria were used, 3%3mm-3%/2mm–2%/2mm with a 10% dose threshold, to compare the calculated and prescribed dose. Results: All centers had a high pass rate for the criteria of 3%/3 mm. For 2D dose, the average of centers mean pass rate was 99.6% (SD: 0.3%) and 99.8% (SD: 0.3%) for respectively H&N and PP patients. For 3D dose, 3D gamma was used to compare the model dose with TPS combined dose. The mean pass rate was 97.7% (SD: 2.8%) and 98.3% (SD: 1.6%). Conclusion: Successful performance of the method for the pilot centers establishes the method for dosimetric multi-center credentialing. The results are promising and show a high level of gamma agreement and, the procedure is efficient, consistent and inexpensive. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.« less
Voskanian, K Sh
2004-01-01
Oncoginic transformations of mouse fibroblasts C3H10T1/2 after exposure to proton energies 150 and 584 MeV were compared with fibroblast effects of gamma-radiation. Prior to exposure, cell populations (2.7 x 10(3) cells/cm2) were inoculated in plastic vials with the surface area of 75 cm2 and cultivated 11 days. Survivability was determined by comparing the number of cell colonies in irradiated and non-irradiated (control) vials. Transformation rate was calculated by dividing the total transformation focus number by the number of survived cells in a vial. Rate of oncogenic transformations after gamma- and proton (584 MeV) irradiation was essentially identical, i.e. the parameter grew rapidly at the doses < 1 Gy and slowed down at the doses > 1 Gy. In the dose interval between 1 and 5 Gy, transformation rate for proton energy 150 MeV was found low compared with gamma-radiation and proton energy 584 MeV. It is hypothesized that the different transformation rate after exposure to proton energy 150 MeV is linked with the high linear energy transfer as compared with the proton energy of 584 MeV and gamma-radiation.
Dorr, R T; Briggs, A; Kintzel, P; Meyers, R; Chow, H-H S; List, A
2003-04-01
The pharmacokinetics of two etoposide (E) formulations were evaluated in patients with refractory hematologic malignancies receiving high-dose conditioning with autologous stem cell transplantation. Patients were randomized to either E at 800 mg/m(2) (containing polysorbate 80 and polyethylene glycol) or etoposide phosphate (EP) at 910 mg/m(2) on days -7 and -5, prior to melphalan, 80 mg/m(2) on day -5. On day -3, EP was repeated. Plasma E was analyzed after each formulation on days -7 and -5 to compare intrapatient pharmacokinetics. In total, 10 patients were treated: four each with multiple myeloma or Hodgkin's disease and two with non-Hodgkin's lymphoma. Mucositis was the major toxicity with seven patients. EP first produced grade 3 mucositis. There was no procedure-related mortality and eight patients remained alive 1 year post-transplant. Cumulative etoposide exposure (AUC) was slightly greater with EP (P=0.056). Conversely, the volume of distribution was slightly, 33%, larger (P=0.052) and clearance was increased with the E infusion (P=0.14). As none of the differences reached statistical significance, both E formulations appear to be pharmacokinetically equivalent in the high-dose transplant setting. The combination of high-dose EP with melphalan is an active preparative regimen prior to ABMT for hematologic malignancies.
Antar, A; Otrock, Z K; Kharfan-Dabaja, M A; Ghaddara, H A; Kreidieh, N; Mahfouz, R; Bazarbachi, A
2015-06-01
The optimal stem cell mobilization regimen for patients with multiple myeloma (MM) remains undefined. We retrospectively compared our experience in hematopoietic cell mobilization in 83 MM patients using fractionated high-dose CY and G-CSF with G-CSF plus preemptive plerixafor. All patients in the CY group (n=56) received fractionated high-dose CY (5 g/m(2) divided into five doses of 1 g/m(2) every 3 h) with G-CSF. All patients in the plerixafor group (n=27) received G-CSF and plerixafor preemptively based on an established algorithm. Compared with plerixafor, CY use was associated with higher total CD34+ cell yield (7.5 × 10(6) vs 15.5 × 10(6) cells/kg, P=0.005). All patients in both groups yielded ⩾4 × 10(6) CD34+ cells/kg. Conversely, CY use was associated with high frequency of febrile neutropenia, blood and platelet transfusions need and hospitalizations. The average total cost of mobilization in Lebanon was slightly higher in the plerixafor group ($7886 vs $7536; P=0.16). Our data indicate robust stem cell mobilization in MM patients with either fractionated high-dose CY and G-CSF or G-CSF alone with preemptive plerixafor. The chemo-mobilization approach was associated with twofold stem cell yield, slightly lower cost but significantly increased toxicity.
Saito, M; Kikuchi, Y; Kawarai Lefor, A; Hoshina, M
2017-01-01
Background. High-dose inhaled steroid therapy has been shown to be effective in children and adults with asthma exacerbations. However, few reports are available regarding its efficacy for asthma exacerbations in younger children. Objective. In this study, we administered high-dose nebulized budesonide therapy for mild asthma exacerbations in children < 3 years of age and compared its efficacy and safety with systemic steroid therapy. Methods. This study included children < 3 years old with mild asthma exacerbations. Patients were randomly assigned to two groups: the BIS group was given 1 mg of nebulized budesonide twice daily, and the PSL group received prednisolone 0.5 mg/kg iv three times daily. Days to disappearance of wheezing, days of steroid use, days of oxygen use, serum cortisol level, and incidence of adverse events during treatment were compared between the groups. Result. Wheezing disappeared after an average of five days, and steroids were administered for an average of five days in both groups, with no significant difference in days of oxygen use. Serum cortisol levels at initiation and during the course of treatment remained unchanged in the BIS group, and were decreased in the PSL group; however, the decrease in the latter group was not pathologic. Conclusion. For children < 3 years old with mild asthma exacerbations, high-dose nebulized budesonide therapy is equally as effective as systemic steroid therapy.
Li, X; Han, K Q; Shi, Y N; Men, S Z; Li, S; Sun, M H; Dong, H; Lu, J J; Ma, L J; Zhao, M; Li, D; Liu, W
2017-02-07
Objective: To investigate the effects and possible mechanisms of ursodeoxycholic acid (UDCA) on myocardial fibrosis in mice. Method: To observe the expression of transforming growth factor(TGF) -β1, CTGF, MMPs and the degree of myocardial fibrosis, 61 male Kunming mice were randomly divided into normal group, low dose UDCA group, high dose of UDCA group, spironolactone group, and the control group.Isoproterenol (ISO) injection was given subcutaneously (30 d) to make the model of myocardial fibrosis.Corresponding anti-fibrosis drugs (UDCA or spironolactone) were given by gavage.HE staining and Masson staining were performed to explore the inflammation and fibrosis in the myocardium.The expression of collagen Ⅰ and collagen Ⅲ protein was detected by immunohistochemistry to evaluate the degree of fibrosis among the groups.Western blot was used to detect the expression of transforming growth factor, (TGF)-β1, connective tissue growth factor (CTGF), matrix metalloproteinase (MMP)-2, -9, tissue inhibitor of metalloproteinase (TIMP)-4, -1 and anti-phospho-NFKBIA (p-IκB-α) inhibitor of NF-κB (IκB) protein in myocardium. Results: HE and Masson staining results showed that in the normal group, myocardial fibrosis is less, while the control group showed a large amount of fibrotic tissue ( P <0.05). Tissue fibrosis in the low/high dose UDCA group and spironolactone group was significantly reduced compared with the control group ( P <0.05), in which high dose of UDCA reduces fibrosis more significantly.Immunohistochemistry results showed that collagen Ⅰ and collagen Ⅲ protein expression was significantly increased ( P <0.05). Whereas in the low/high UDCA dose group and spironolactone group, collagen Ⅰ and collagen Ⅲ expression were significantly decreased ( P <0.05), the high UDCA dose group decreased more significantly.Western blot results suggest that TGFβ-1 expression in the myocardial tissue was significantly increased compared to the normal group ( P <0.05), whereas low/high UDCA dose group and spironolactone group, TGFβ-1 protein expression were significantly decreased [UDCA(1.52±0.16), (1.02±0.12), (1.01±0.21)vs (2.73±0.12), P <0.05], in which high UDCA dose group TGFβ-1 protein expression level decreased more significantly.However, there was no significant difference in the expression of CTGF, MMP2/9 and TIMP1/4 protein among the groups ( P >0.05). UDCA decrease p-IκB-α expression and increase IκB protein expression dose-dependently. Conclusions: UDCA can relieve isoproterenol induced myocardial fibrosis and reduce the myocardial collagen Ⅰ and collagen Ⅲ deposition in a dose dependent manner.Down-regulating of TGFβ-1 protein expression through the inhibition of TGR5-NF-κB signal transduction pathway might be a potential mechanism underlying UDCA's effects.
SU-E-T-765: Treatment Planning Comparison of SFUD Proton and 4Ï€ Radiotherapy for Prostate Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tran, A; Woods, K; Yu, V
2015-06-15
Purpose: Single-Field Uniform Dose (SFUD) proton scanning beams and non-coplanar 4π intensity-modulated radiation therapy (IMRT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate treatment. Methods: Five prostate patients were planned using 4π radiotherapy and SFUD to an initial dose of 54Gy to a planning target volume (PTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2Gy to the prostate for a total dose of 79.2 Gy. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams usingmore » a greedy column generation algorithm. The SFUD plans utilized two coplanar, parallel-opposing lateral scanning beams. The SFUD plan PTV was modified to account for range uncertainties while keeping an evaluation PTV identical to that of the X-ray plans for comparison. PTV doses, bladder and rectum dose volumes (V40, V45, V60, V70, V75.6, and V80), R50, and PTV homogeneity index (D95/D5) were evaluated. Results: Compared to SFUD, 4π resulted in 6.8% lower high dose spillage as indicated by R50. Bladder and rectum mean doses were 38.3% and 28.2% lower for SFUD, respectively. However, bladder and rectum volumes receiving >70Gy were 13.1% and 12% greater using proton SFUD. Due to the parallel-opposing beam arrangement, SFUD resulted in greater femoral head (87.8%) and penile bulb doses (43.7%). 4π PTV doses were slightly more homogeneous (HI 0.99 vs. 0.98) than the SFUD dose. Conclusion: Proton is physically advantageous to reduce the irradiated normal volume and mean doses to the rectum and bladder but it is also limited in the beam orientations and entrance dose, which resulted in greater doses to the femoral heads and penile bulb, and larger volumes of rectum and bladder exposed to high dose due to the required robust PTV definition. This project is supported by Varian Medical Systems.« less
Li, Mei-Yi; Zhang, Yan-Bo; Zuo, Huan; Liu, Li-Li; Niu, Jing-Zhong
2012-02-25
The present study was to investigate the effect of Salvia miltiorrhiza Bunge. f. alba (SMA) pharmacological pretreatment on apoptosis of cultured hippocampal neurons from neonate rats under oxygen-glucose deprivation (OGD). Cultured hippocampal neurons were randomly divided into five groups (n = 6): normal plasma group, low dose SMA plasma (2.5%) group, middle dose SMA plasma (5%) group, high dose SMA plasma (10%) group and control group. The hippocampal neurons were cultured and treated with plasma from adult Wistar rats intragastrically administered with saline or aqueous extract of SMA. The apoptosis of neurons was induced by glucose-free Earle's solution containing 1 mmol/L Na2S2O4 and labeled by MTT and Annexin V/PI double staining. Moreover, protein expressions of Bcl-2 and Bax were detected by immunofluorescence. The results showed that few apoptotic cells were observed in control group, whereas the number of apoptotic cells was greatly increased in normal plasma group and low dose SMA plasma group. Both middle and high dose SMA plasma could protect cultured hippocampal neurons from apoptosis induced by OGD (P < 0.05). The protective effect of high dose SMA plasma was stronger than that of middle one (P < 0.05). Compared to control, normal plasma and low dose SMA plasma groups, middle and high dose SMA plasma groups both showed significantly higher levels of Bcl-2 (P < 0.05 or 0.01), whereas expressions of Bax was opposite. There were no significant differences of Bcl-2 and Bax expressions between middle and high dose SMA plasma groups. Number of Bcl-2- and Bax-positive cells had similar tendency. Bcl-2/Bax (number of positive cells) ratio was higher in high dose SMA plasma group than those of all the other groups (P < 0.05 or 0.01). These results suggest that pharmacological pretreatment of blood plasma containing middle and high dose SMA could raise viability and inhibit apoptosis of OGD-injured hippocampal neurons by up-regulating the expression of Bcl-2 and down-regulating the expression of Bax.
NASA Astrophysics Data System (ADS)
Wang, Wei; Shi, Jinming; Liang, Shujian; Lei, Huang; Shenyi, Zhang; Sun, Yeqing
In previous work, we compared the proteomic profiles of rice plants growing after seed space-flights with ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) and found that the protein expression profiles were changed after seed space environment exposures. Spaceflight represents a complex environmental condition in which several interacting factors such as cosmic radiation, microgravity and space magnetic fields are involved. Rice seed is in the process of dormant of plant development, showing high resistance against stresses, so the highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to seeds. To further investigate the radiation effects of space environment, we performed on-ground simulated HZE particle radiation and compared between the proteomes of seed irra-diated plants and seed spaceflight (20th recoverable satellite) plants from the same rice variety. Space ionization shows low-dose but high energy particle effects, for searching the particle effects, ground radiations with the same low-dose (2mGy) but different liner energy transfer (LET) values (13.3KeV/µm-C, 30KeV/µm-C, 31KeV/µm-Ne, 62.2KeV/µm-C, 500Kev/µm-Fe) were performed; using 2-D DIGE coupled with clustering and principle component analysis (PCA) for data process and comparison, we found that the holistic protein expression patterns of plants irradiated by LET-62.2KeV/µm carbon particles were most similar to spaceflight. In addition, although space environment presents a low-dose radiation (0.177 mGy/day on the satellite), the equivalent simulated radiation dose effects should still be evaluated: radiations of LET-62.2KeV/µm carbon particles with different cumulative doses (2mGy, 20mGy, 200mGy, 2000mGy) were further carried out and resulted that the 2mGy radiation still shared most similar proteomic profiles with spaceflight, confirming the low-dose effects of space radiation. Therefore, in the protein expression level, ground simulation method could be utilized to simu-late the space radiation biological effects and such a comparative proteomic work might explain both energy and dose effects of space radiation environment.
NASA Astrophysics Data System (ADS)
Carpentieri, C.; Schwarz, C.; Ludwig, J.; Ashfaq, A.; Fiederle, M.
2002-07-01
High precision concerning the dose calibration of X-ray sources is required when counting and integrating methods are compared. The dose calibration for a dental X-ray tube was executed with special dose calibration equipment (dosimeter) as function of exposure time and rate. Results were compared with a benchmark spectrum and agree within ±1.5%. Dead time investigations with the Medipix1 photon-counting chip (PCC) have been performed by rate variations. Two different types of dead time, paralysable and non-paralysable will be discussed. The dead time depends on settings of the front-end electronics and is a function of signal height, which might lead to systematic defects of systems. Dead time losses in excess of 30% have been found for the PCC at 200 kHz absorbed photons per pixel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendoza-Moctezuma, A. I.; Aguilar, J. Garcia; Garcia-Garduno, O. A.
Interventional cardiology procedures are an effective alternative for the reestablishment of correct sanguineous circulation in the heart. However, this kind of procedures exposes to the patients to a relatively high radiation doses. Usually, the surface peak skin dose is evaluated using a visual scale with a comparator strip, nevertheless, even if the comparator strip provides a simple and quick method for estimating the dose it has an uncertainty of {+-}25%. For this reason, a better evaluation method is needed. The objective of our project is to determine the surface peak skin dose of interventional cardiology procedures using GafChromic XR-RV2 filmmore » together with a commercial flatbed scanner in reflection mode. Here we report a protocol to handle GafChromic XR-RV2 film using a commercial flat bed scanner in reflection mode aiming at an uncertainty of {+-}3%.« less
Comparison of potential risks of lactic acidosis induction by biguanides in rats.
Bando, Kiyoko; Ochiai, Shoko; Kunimatsu, Takeshi; Deguchi, Jiro; Kimura, Juki; Funabashi, Hitoshi; Seki, Takaki
2010-10-01
Lactic acidosis has been considered to be a side effect of some biguanides, after phenformin was withdrawn from the market because of its association with lactic acidosis. The potential of lactic acidosis induced by biguanides at human therapeutic exposure levels, however, has not been examined. Then, we compared the risk of lactic acid at doses providing exposure levels comparable to human therapeutic doses. Metformin and phenformin were orally administered to rats for up to 28 days, and plasma drug concentrations and blood lactic acid levels were examined. Metformin did not elevate lactic acid levels at the dose corresponding to higher systemic drug exposure than human therapeutic level, even for repeated doses. In contrast, phenformin elevated lactic acid levels at the dose corresponding to lower exposure than human therapeutic level, and sustained high levels were observed up to 24h post-dose; furthermore, these changes were enhanced by repeated doses. Direct comparison at each rat equivalent dose clearly indicated that lactic acid levels of phenformin were higher than those of metformin. These non-clinical findings suggest that metformin dose not increase lactic acid levels like phenformin does, and therefore may not increase the risk for lactic acidosis at human therapeutic exposure level. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Inhibitory effects of 3-bromopyruvate on human gastric cancer implant tumors in nude mice.
Xian, Shu-Lin; Cao, Wei; Zhang, Xiao-Dong; Lu, Yun-Fei
2014-01-01
Gastric cancer is a common malignant tumor. Our previous study demonstrated inhibitory effects of 3-bromopyruvate (3-BrPA) on pleural mesothelioma. Moreover, we found that 3-BrPA could inhibit human gastric cancer cell line SGC-7901 proliferation in vitro, but whether similar effects might be exerted in vivo have remained unclear. To investigate the effect of 3-BrPA to human gastric cancer implant tumors in nude mice. Animals were randomly divided into 6 groups: 3-BrPA low, medium and high dose groups, PBS negative control group 1 (PH7.4), control group 2 (PH 6.8-7.8) and positive control group receiving 5-FU. The TUNEL method was used to detect apoptosis, and cell morphology and structural changes of tumor tissue were observed under transmission electron microscopy (TEM). 3-BrPA low, medium, high dose group, and 5-FU group, the tumor volume inhibition rates were 34.5%, 40.2%, 45.1%, 47.3%, tumor volume of experimental group compared with 2 PBS groups (p<0.05), with no significant difference between the high dose and 5-FU groups (p>0.05). TEM showed typical characteristics of apoptosis. TUNEL demonstrated apoptosis indices of 28.7%, 39.7%, 48.7% for the 3-BrPA low, medium, high dose groups, 42.2% for the 5-FU group and 5% and 4.3% for the PBS1 (PH7.4) and PBS2 (PH6.8-7.8) groups. Compared each experimental group with 2 negative control groups, there was significant difference (p<0.05); there was no significant difference between 5-FU group and medium dose group (p>0.05), but there was between the 5-FU and high dose groups (p<0.05). This study indicated that 3-BrPA in vivo has strong inhibitory effects on human gastric cancer implant tumors in nude mice .
Holl, Katsiaryna; Sauboin, Christophe; Amodio, Emanuele; Bonanni, Paolo; Gabutti, Giovanni
2016-10-21
Varicella is a highly infectious disease with a significant public health and economic burden, which can be prevented with childhood routine varicella vaccination. Vaccination strategies differ by country. Some factors are known to play an important role (number of doses, coverage, dosing interval, efficacy and catch-up programmes), however, their relative impact on the reduction of varicella in the population remains unclear. This paper aims to help policy makers prioritise the critical factors to achieve the most successful vaccination programme with the available budget. Scenarios assessed the impact of different vaccination strategies on reduction of varicella disease in the population. A dynamic transmission model was used and adapted to fit Italian demographics and population mixing patterns. Inputs included coverage, number of doses, dosing intervals, first-dose efficacy and availability of catch-up programmes, based on strategies currently used or likely to be used in different countries. The time horizon was 30 years. Both one- and two-dose routine varicella vaccination strategies prevented a comparable number of varicella cases with complications, but two-doses provided broader protection due to prevention of a higher number of milder varicella cases. A catch-up programme in susceptible adolescents aged 10-14 years old reduced varicella cases by 27-43 % in older children, which are often more severe than in younger children. Coverage, for all strategies, sustained at high levels achieved the largest reduction in varicella. In general, a 20 % increase in coverage resulted in a further 27-31 % reduction in varicella cases. When high coverage is reached, the impact of dosing interval and first-dose vaccine efficacy had a relatively lower impact on disease prevention in the population. Compared to the long (11 years) dosing interval, the short (5 months) and medium (5 years) interval schedules reduced varicella cases by a further 5-13 % and 2-5 %, respectively. Similarly, a 10 % increase in first-dose efficacy (from 65 to 75 % efficacy) prevented 2-5 % more varicella cases, suggesting it is the least influential factor when considering routine varicella vaccination. Vaccination strategies can be implemented differently in each country depending on their needs, infrastructure and healthcare budget. However, ensuring high coverage remains the critical success factor for significant prevention of varicella when introducing varicella vaccination in the national immunisation programme.
Characteristics and Dose Levels for Spent Reactor Fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coates, Cameron W
2007-01-01
Current guidance considers highly radioactive special nuclear materials to be those materials that, unshielded, emit a radiation dose [rate] measured at 1 m which exceeds 100 rem/h. Smaller, less massive fuel assemblies from research reactors can present a challenge from the point of view of self protection because of their size (lower dose, easier to handle) and the desirability of higher enrichments; however, a follow-on study to cross-compare dose trends of research reactors and power reactors was deemed useful to confirm/verify these trends. This paper summarizes the characteristics and dose levels of spent reactor fuels for both research reactors andmore » power reactors and extends previous studies aimed at quantifying expected dose rates from research reactor fuels worldwide.« less
Nootash, Shahab; Sheikhzadeh, Najmeh; Baradaran, Behzad; Oushani, Ali Khani; Maleki Moghadam, Mohammad Reza; Nofouzi, Katayoon; Monfaredan, Amir; Aghebati, Leili; Zare, Fatemeh; Shabanzadeh, Sadigheh
2013-12-01
Present study elucidates the efficacy of green tea (Camellia sinensis) on growth performance, immune and antioxidant systems and cytokine gene expression in rainbow trout tissues. Green tea was supplemented at 20, 100, and 500 mg kg(-1) diet and fed to fish (average weight: 23.5 g) for 35 days. No remarkable changes in growth performance were observed among all test groups. Lower lipid peroxidation product and higher superoxide dismutase activity were noted in fish received the medium dose of green tea. Significant increase in serum bactericidal activity and total protein were recorded in all treatment groups. All doses of green tea up-regulated Interleukin-1β transcription in the spleen, while Interleukin-1β mRNA level decreased significantly in the kidney of low dose of green tea. Interleukin-6 mRNA level was up-regulated in the spleen of high dose of green tea and liver of middle and high doses of green tea. High dose and medium dose of green tea up-regulated the interleukin-8 transcription in the kidney and liver, respectively. Meanwhile, green tea inhibited the production of interleukin-10 in all treatment groups compared with control group. Medium dose of green tea up-regulated tumor necrosis factor-α transcription in all fish tissues, while high dose and low dose of green tea enhanced tumor necrosis factor-α mRNA levels in the kidney and spleen, respectively. Present study suggests that green tea especially at 100 mg kg(-1) feed may effectively enhance the antioxidant system and immune system in rainbow trout. Copyright © 2013 Elsevier Ltd. All rights reserved.
Mitsiou, Eudoxia; Boutari, Chrysoula; Kotsis, Vasilios; Georgianou, Eleni; Doumas, Michael; Karagiannis, Asterios; Athyros, Vasilios G
2018-01-01
Arterial Stiffness (AS) and Non-Alcoholic Fatty Liver Diseases (NAFLD) are 2 related, prevalent, risk predictors of Cardiovascular Disease (CVD). We assessed the effect of low dose (5 mg/day) vs. high dose (20-40 mg/day) rosuvastatin on aortic elasticity and central haemodynamics as well as on NAFLD in patients with Arterial Hypertension (AH). Forty patients with optimally controlled AH were randomised to 2 rosuvastatin doses and followed for 6 months. 24h AS was assessed by Mobil-O-Graph, which calculates (adjusted for age and gender) Pulse Wave Velocity (PWV), adjusted for Heart Rate (HR) augmentation index (AIx75%) and central haemodynamics. The diagnosis of NAFLD was based on >5% liver steatosis on ultrasound and moderately elevated serum levels of liver enzymes. Both doses of rosuvastatin reduced Central Pulse Pressure (cPP), PWV and AIx75% (adjusted for HR) to normal values (p = NS adjusted for age, gender and HR). Liver enzymes were reduced in those with NAFLD to normal, but steatosis was reduced more by the 20-40 mg/day rosuvastatin dose (p=0.01) compared with the 5 mg/day dose. Both doses of rosuvastatin had a beneficial effect on AS; the high dose was more efficient in reducing PWVs and central haemodynamics, and also the high dose was more effective in ameliorating NAFLD. Given that AH control was optimal and lipid values attained targets, 4 other CVD predictors were also addressed. Larger and longer term studies are needed to demonstrate the clinical benefit of such treatment preference. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
TU-EF-304-09: Quantifying the Biological Effects of Therapeutic Protons by LET Spectrum Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guan, F; Bronk, L; Kerr, M
2015-06-15
Purpose: To correlate in vitro cell kill with linear energy transfer (LET) spectra using Monte Carlo simulations and knowledge obtained from previous high-throughput in vitro proton relative biological effectiveness (RBE) measurements. Methods: The Monte Carlo simulation toolkit Geant4 was used to design the experimental setups and perform the dose, dose-averaged LET, and LET spectra calculations. The clonogenic assay was performed using the H460 lung cancer cell line in standard 6-well plates. Using two different experimental setups, the same dose and dose-averaged LET (12.6 keV/µm) was delivered to the cell layer; however, each respective energy or LET spectrum was different. Wemore » quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous RBE measurements) events in the LET spectra separately for these two setups as 39% and 53%. 8 dose levels with 1 Gy increments were delivered. The photon reference irradiation was performed using 6 MV x-rays from a LINAC. Results: The survival curves showed that both proton irradiations demonstrated an increased RBE compared to the reference photon irradiation. Within the proton-irradiated cells, the setup with 53% dose contribution from high-LET events exhibited the higher biological effectiveness. Conclusion: The experimental results indicate that the dose-averaged LET may not be an appropriate indicator to quantify the biological effects of protons when the LET spectrum is broad enough to contain both low- and high-LET events. Incorporating the LET spectrum distribution into robust intensity-modulated proton therapy optimization planning may provide more accurate biological dose distribution than using the dose-averaged LET. NIH Program Project Grant 2U19CA021239-35.« less
Rao, Srinivas S.; Kong, Wing-Pui; Wei, Chih-Jen; Van Hoeven, Neal; Gorres, J. Patrick; Nason, Martha; Andersen, Hanne; Tumpey, Terrence M.; Nabel, Gary J.
2010-01-01
Efforts to develop a broadly protective vaccine against the highly pathogenic avian influenza A (HPAI) H5N1 virus have focused on highly conserved influenza gene products. The viral nucleoprotein (NP) and ion channel matrix protein (M2) are highly conserved among different strains and various influenza A subtypes. Here, we investigate the relative efficacy of NP and M2 compared to HA in protecting against HPAI H5N1 virus. In mice, previous studies have shown that vaccination with NP and M2 in recombinant DNA and/or adenovirus vectors or with adjuvants confers protection against lethal challenge in the absence of HA. However, we find that the protective efficacy of NP and M2 diminishes as the virulence and dose of the challenge virus are increased. To explore this question in a model relevant to human disease, ferrets were immunized with DNA/rAd5 vaccines encoding NP, M2, HA, NP+M2 or HA+NP+M2. Only HA or HA+NP+M2 vaccination conferred protection against a stringent virus challenge. Therefore, while gene-based vaccination with NP and M2 may provide moderate levels of protection against low challenge doses, it is insufficient to confer protective immunity against high challenge doses of H5N1 in ferrets. These immunogens may require combinatorial vaccination with HA, which confers protection even against very high doses of lethal viral challenge. PMID:20352112
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferreyra, M; Salinas Aranda, F; Dodat, D
Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical andmore » dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.« less
Simultaneous integrated protection : A new concept for high-precision radiation therapy.
Brunner, Thomas B; Nestle, Ursula; Adebahr, Sonja; Gkika, Eleni; Wiehle, Rolf; Baltas, Dimos; Grosu, Anca-Ligia
2016-12-01
Stereotactic radiotherapy near serial organs at risk (OAR) requires special caution. A novel intensity-modulated radiotherapy (IMRT) prescription concept termed simultaneous integrated protection (SIP) for quantifiable and comparable dose prescription to targets very close to OAR is described. An intersection volume of a planning risk volume (PRV) with the total planning target volume (PTV) defined the protection volume (PTV SIP ). The remainder of the PTV represented the dominant PTV (PTV dom ). Planning was performed using IMRT. Dose was prescribed to PTV dom according to ICRU in 3, 5, 8, or 12 fractions. Constraints to OARs were expressed as absolute and as equieffective doses at 2 Gy (EQD2). Dose to the gross risk volume of an OAR was to respect constraints. Violation of constraints to OAR triggered a planning iteration at increased fractionation. Dose to PTV SIP was required to be as high as possible within the constraints to avoid local relapse. SIP was applied in 6 patients with OAR being large airways (n = 2) or bowel (n = 4) in 3, 5, 8, and 12 fractions in 1, 3, 1, and 1 patients, respectively. PTVs were 14.5-84.9 ml and PTV SIP 1.8-3.9 ml (2.9-13.4 % of PTV). Safety of the plans was analyzed from the absolute dose-volume histogram (dose to ml). The steepness of dose fall-off could be determined by comparing the dose constraints to the PRVs with those to the OARs (Wilcoxon test p = 0.001). Constraints were respected for the corresponding OARs. All patients had local control at a median 9 month follow-up and toxicity was low. SIP results in a median dose of ≥100 % to PTV, to achieve high local control and low toxicity. Longer follow-up is required to verify results and a prospective clinical trial is currently testing this new approach in chest and abdomen stereotactic body radiotherapy.
SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shusharina, N; Khan, F; Sharp, G
2015-06-15
Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT wasmore » designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.« less
Liu, C; Wang, X D; Bronson, R T; Smith, D E; Krinsky, N I; Russell, R M
2000-12-01
There remains a remarkable discordance between the results of observational epidemiological studies and intervention trials using beta-carotene as a potential chemopreventive agent. One question that needs to be examined is whether the adverse outcomes of human beta-carotene trials are related to the large doses of beta-carotene that were administered. In the present study, ferrets were given a physiological (low) dose or a pharmacological (high) dose of beta-carotene supplementation (0.43 mg versus 2.4 mg/kg body wt/day, which is equivalent to 6 mg versus 30 mg/day in humans) and exposed to cigarette smoke for 6 months. We investigated the effects of these doses of beta-carotene on retinoid concentrations, expression of retinoic acid receptors (RARs), activator protein 1 (AP-1; c-Jun and c-Fos), cyclin D1, proliferating cellular nuclear antigen (PCNA), and histopathological changes in the lungs of both normal and cigarette smoke-exposed ferrets. Thirty-six male ferrets were treated in six groups-control, smoke-exposed (SM), low-dose beta-carotene (LBC), high-dose beta-carotene (HBC), low-dose beta-carotene plus smoke exposure (LBC+SM) or high-dose beta-carotene plus smoke exposure (HBC+SM)-for 6 months. Retinoic acid concentration and RAR beta gene expression, but not expression of RAR alpha and RAR gamma, was reduced in the lung tissue of HBC+SM, HBC, SM and LBC+SM ferrets, but not in that of LBC ferrets, as compared with the control group. Expression of AP-1 and PCNA was greater in HBC+SM, HBC, SM and LBC+SM ferrets, but not in the LBC ferrets, as compared with the control group. Increased amounts of cyclin D1 and keratinized squamous metaplasia were observed in the lung tissue of HBC+SM, HBC and SM groups but not in that of the LBC+SM, LBC or control groups. These data suggest that, in contrast with a pharmacological dose of beta-carotene, a physiological dose of beta-carotene in smoke-exposed ferrets has no potentially detrimental effects and may afford weak protection against lung damage induced by cigarette smoke.
In vivo urethral dose measurements: a method to verify high dose rate prostate treatments.
Brezovich, I A; Duan, J; Pareek, P N; Fiveash, J; Ezekiel, M
2000-10-01
Radiation doses delivered in high dose rate (HDR) brachytherapy are susceptible to many inaccuracies and errors, including imaging, planning and delivery. Consequently, the dose delivered to the patient may deviate substantially from the treatment plan. We investigated the feasibility of using TLD measurements in the urethra to estimate the discrepancy in treatments for prostate cancer. The dose response of the 1 mm diam, 6 mm long LiF rods that we used for the in vivo measurements was calibrated with the 192Ir HDR source, as well as a 60Co teletherapy unit. A train of 20 rods contained in a sterile plastic tube was inserted into the urethral (Foley) catheter for the duration of a treatment fraction, and the measured doses were compared to the treatment plan. Initial results from a total of seven treatments in four patients show good agreement between theory and experiment. Analysis of any one treatment showed agreement within 11.7% +/- 6.2% for the highest dose encountered in the central prostatic urethra, and within 10.4% +/- 4.4% for the mean dose. Taking the average over all seven treatments shows agreement within 1.7% for the maximum urethral dose, and within 1.5% for the mean urethral dose. Based on these initial findings it seems that planned prostate doses can be accurately reproduced in the clinic.
Bassler, Niels; Kantemiris, Ioannis; Karaiskos, Pantelis; Engelke, Julia; Holzscheiter, Michael H; Petersen, Jørgen B
2010-04-01
Antiprotons have been suggested as a possibly superior modality for radiotherapy, due to the energy released when antiprotons annihilate, which enhances the Bragg peak and introduces a high-LET component to the dose. However, concerns are expressed about the inferior lateral dose distribution caused by the annihilation products. We use the Monte Carlo code FLUKA to generate depth-dose kernels for protons, antiprotons, and carbon ions. Using these we then build virtual treatment plans optimized according to ICRU recommendations for the different beam modalities, which then are recalculated with FLUKA. Dose-volume histograms generated from these plans can be used to compare the different irradiations. The enhancement in physical and possibly biological dose from annihilating antiprotons can significantly lower the dose in the entrance channel; but only at the expense of a diffuse low dose background from long-range secondary particles. Lateral dose distributions are improved using active beam delivery methods, instead of flat fields. Dose-volume histograms for different treatment scenarios show that antiprotons have the potential to reduce the volume of normal tissue receiving medium to high dose, however, in the low dose region antiprotons are inferior to both protons and carbon ions. This limits the potential usage to situations where dose to normal tissue must be reduced as much as possible. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Lachenmeier, Dirk W; Rehm, Jürgen
2015-01-30
A comparative risk assessment of drugs including alcohol and tobacco using the margin of exposure (MOE) approach was conducted. The MOE is defined as ratio between toxicological threshold (benchmark dose) and estimated human intake. Median lethal dose values from animal experiments were used to derive the benchmark dose. The human intake was calculated for individual scenarios and population-based scenarios. The MOE was calculated using probabilistic Monte Carlo simulations. The benchmark dose values ranged from 2 mg/kg bodyweight for heroin to 531 mg/kg bodyweight for alcohol (ethanol). For individual exposure the four substances alcohol, nicotine, cocaine and heroin fall into the "high risk" category with MOE < 10, the rest of the compounds except THC fall into the "risk" category with MOE < 100. On a population scale, only alcohol would fall into the "high risk" category, and cigarette smoking would fall into the "risk" category, while all other agents (opiates, cocaine, amphetamine-type stimulants, ecstasy, and benzodiazepines) had MOEs > 100, and cannabis had a MOE > 10,000. The toxicological MOE approach validates epidemiological and social science-based drug ranking approaches especially in regard to the positions of alcohol and tobacco (high risk) and cannabis (low risk).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jani, Ashish; Shaikh, Fauzia; Barton, Sunjay
Purpose: To characterize the effects of high-dose radiation therapy (HDRT) on neuroblastoma tumor vasculature, including the endothelial cell (EC)–pericyte interaction as a potential target for combined treatment with antiangiogenic agents. Methods and Materials: The vascular effects of radiation therapy were examined in a xenograft model of high-risk neuroblastoma. In vivo 3-dimensional contrast-enhanced ultrasonography (3D-CEUS) imaging and immunohistochemistry (IHC) were performed. Results: HDRT significantly reduced tumor blood volume 6 hours after irradiation compared with the lower doses used in conventionally fractionated radiation. There was a 63% decrease in tumor blood volume after 12-Gy radiation compared with a 24% decrease after 2 Gy. Analysis ofmore » tumor vasculature by lectin angiography showed a significant loss of small vessel ends at 6 hours. IHC revealed a significant loss of ECs at 6 and 72 hours after HDRT, with an accompanying loss of immature and mature pericytes at 72 hours. Conclusions: HDRT affects tumor vasculature in a manner not observed at lower doses. The main observation was an early reduction in tumor perfusion resulting from a reduction of small vessel ends with a corresponding loss of endothelial cells and pericytes.« less
Lachenmeier, Dirk W.; Rehm, Jürgen
2015-01-01
A comparative risk assessment of drugs including alcohol and tobacco using the margin of exposure (MOE) approach was conducted. The MOE is defined as ratio between toxicological threshold (benchmark dose) and estimated human intake. Median lethal dose values from animal experiments were used to derive the benchmark dose. The human intake was calculated for individual scenarios and population-based scenarios. The MOE was calculated using probabilistic Monte Carlo simulations. The benchmark dose values ranged from 2 mg/kg bodyweight for heroin to 531 mg/kg bodyweight for alcohol (ethanol). For individual exposure the four substances alcohol, nicotine, cocaine and heroin fall into the “high risk” category with MOE < 10, the rest of the compounds except THC fall into the “risk” category with MOE < 100. On a population scale, only alcohol would fall into the “high risk” category, and cigarette smoking would fall into the “risk” category, while all other agents (opiates, cocaine, amphetamine-type stimulants, ecstasy, and benzodiazepines) had MOEs > 100, and cannabis had a MOE > 10,000. The toxicological MOE approach validates epidemiological and social science-based drug ranking approaches especially in regard to the positions of alcohol and tobacco (high risk) and cannabis (low risk). PMID:25634572
Microglial disruption in young mice with early chronic lead exposure☆
Sobin, Christina; Montoya, Mayra Gisel Flores; Parisi, Natali; Schaub, Tanner; Cervantes, Miguel; Armijos, Rodrigo X.
2013-01-01
The mechanisms by which early chronic lead (Pb) exposure alter brain development have not been identified. We examined neuroimmune system effects in C57BL/6J mice with Pb exposure, including levels that may be common among children in lower socioeconomic income environments. Pups were exposed via dams’ drinking water from birth to post-natal day 28 to low, high or no Pb conditions. We compared gene expression of neuroinflammatory markers (study 1); and microglial mean cell body volume and mean cell body number in dentate gyrus, and dentate gyrus volume (study 2). Blood Pb levels in exposed animals at sacrifice (post-natal day 28) ranged from 2.66 to 20.31 μg/dL. Only interleukin-6 (IL6) differed between groups and reductions were dose-dependent. Microglia cell body number also differed between groups and reductions were dose-dependent. As compared with controls, microglia cell body volume was greater but highly variable in only low-dose animals; dentate gyri volumes in low- and high-dose animals were reduced. The results did not support a model of increased neuroinflammation. Instead, early chronic exposure to Pb disrupted microglia via damage to, loss of, or lack of proliferation of microglia in the developing brains of Pb-exposed animals. PMID:23598043
High-dose hook effect in six automated human chorionic gonadotrophin assays.
Al-Mahdili, Huda A; Jones, Graham R D
2010-07-01
The high-dose hook effect is a well-known phenomenon of two-site immunoassays including those for human chorionic gonadotrophin (hCG). We investigated the occurrence of a high-dose hook effect in six routinely available hCG assays using a sample with a total hCG concentration of approximately 3,600,000 IU/L. Dilutions of a sample with high hCG concentration were analysed using six common methods: Advia Centaur, Immulite 2000, Dimension RxL, Unicel DxI 800, Roche E170 and Abbott Architect. The measured concentrations and corresponding assay signals were obtained for each method. Performance was compared with manufacturer claims. Four of the tested platforms demonstrated a clear high-dose hook effect, while the other methods showed no hook effect at the highest level tested. Our results indicate that the hook effect may occur in some hCG assays, although the risk of reporting falsely low results was in most cases at higher concentrations than those indicated in manufacturers' product information. Assay design plays a major role in its occurrence. Laboratories should be aware of the assay limitations in this regard.
Detection and distribution of ostreid herpesvirus 1 in experimentally infected Pacific oyster spat.
Segarra, Amélie; Baillon, Laury; Faury, Nicole; Tourbiez, Delphine; Renault, Tristan
2016-01-01
High mortality rates are reported in spat and larvae of Pacific oyster Crassostrea gigas and associated with ostreid herpesvirus 1 (OsHV-1) detection in France. Although the viral infection has been experimentally reproduced in oyster larvae and spat, little knowledge is currently available concerning the viral entry and its distribution in organs and tissues. This study compares OsHV-1 DNA and RNA detection and localization in experimentally infected oysters using two virus doses: a low dose that did not induce any mortality and a high dose inducing high mortality. Real time PCR demonstrated significant differences in terms of viral DNA amounts between the two virus doses. RNA transcripts were detected in oysters receiving the highest dose of viral suspension whereas no transcript was observed in oysters injected with the low dose. This study also allowed observing kinetics of viral DNA and RNA detection in different tissues of oyster spat. Finally, viral detection was significantly different in function of tissues (p<0.005), time (p<0.005) with an interaction between tissues and time (p<0.005) for each probe. Copyright © 2015 Elsevier Inc. All rights reserved.
Weitz, Jeffrey I; Bauersachs, Rupert; Beyer-Westendorf, Jan; Bounameaux, Henri; Brighton, Timothy A; Cohen, Alexander T; Davidson, Bruce L; Holberg, Gerlind; Kakkar, Ajay; Lensing, Anthonie W A; Prins, Martin; Haskell, Lloyd; van Bellen, Bonno; Verhamme, Peter; Wells, Philip S; Prandoni, Paolo
2015-08-31
Patients with unprovoked venous thromboembolism (VTE) are at high risk for recurrence. Although rivaroxaban is effective for extended VTE treatment at a dose of 20 mg once daily, use of the 10 mg dose may further improve its benefit-to-risk ratio. Low-dose aspirin also reduces rates of recurrent VTE, but has not been compared with anticoagulant therapy. The EINSTEIN CHOICE study is a multicentre, randomised, double-blind, active-controlled, event-driven study comparing the efficacy and safety of two once daily doses of rivaroxaban (20 and 10 mg) with aspirin (100 mg daily) for the prevention of recurrent VTE in patients who completed 6-12 months of anticoagulant therapy for their index acute VTE event. All treatments will be given for 12 months. The primary efficacy objective is to determine whether both doses of rivaroxaban are superior to aspirin for the prevention of symptomatic recurrent VTE, while the principal safety outcome is the incidence of major bleeding. The trial is anticipated to enrol 2,850 patients from 230 sites in 31 countries over a period of 27 months. In conclusion, the EINSTEIN CHOICE study will provide new insights into the optimal antithrombotic strategy for extended VTE treatment by comparing two doses of rivaroxaban with aspirin (clinicaltrials.gov NCT02064439).
Menezes, C N; Duarte, R; Dickens, C; Dix-Peek, T; Van Amsterdam, D; John, M-A; Ive, P; Maskew, M; Macphail, P; Fox, M P; Raal, F; Sanne, I; Crowther, N J
2013-04-01
Stavudine is being phased out because of its mitochondrial toxicity and tenofovir (TDF) is recommended as part of first-line highly active antiretroviral therapy (HAART) in South Africa. A prospective, open-label, randomized controlled trial comparing standard- and low-dose stavudine with TDF was performed to assess early differences in adipocyte mtDNA copy number, gene expression and metabolic parameters in Black South African HIV-infected patients. Sixty patients were randomized 1:1:1 to either standard-dose (30-40 mg) or low-dose (20-30 mg) stavudine or TDF (300 mg) each combined with lamivudine and efavirenz. Subcutaneous fat biopsies were obtained at weeks 0 and 4. Adipocyte mtDNA copies/cell and gene expression were measured using quantitative polymerase chain reaction (qPCR). Markers of inflammation and lipid and glucose metabolism were also assessed. A 29% and 32% decrease in the mean mtDNA copies/cell was noted in the standard-dose (P < 0.05) and low-dose stavudine (P < 0.005) arms, respectively, when compared with TDF at 4 weeks. Nuclear respiratory factor-1 (NRF1) and mitochondrial cytochrome B (MTCYB) gene expression levels were affected by stavudine, with a significantly (P < 0.05) greater fall in expression observed with the standard, but not the low dose compared with TDF. No significant differences were observed in markers of inflammation and lipid and glucose metabolism. These results demonstrate early mitochondrial depletion among Black South African patients receiving low and standard doses of stavudine, with preservation of gene expression levels, except for NRF1 and MTCYB, when compared with patients on TDF. © 2012 British HIV Association.
Morimoto, Linda Nayeli; Kamaya, Aya; Boulay-Coletta, Isabelle; Fleischmann, Dominik; Molvin, Lior; Tian, Lu; Fisher, George; Wang, Jia; Willmann, Jürgen K
2017-09-01
To compare image quality and lesion conspicuity of reduced dose (RD) CT with model-based iterative reconstruction (MBIR) compared to standard dose (SD) CT in patients undergoing oncological follow-up imaging. Forty-four cancer patients who had a staging SD CT within 12 months were prospectively included to undergo a weight-based RD CT with MBIR. Radiation dose was recorded and tissue attenuation and image noise of four tissue types were measured. Reproducibility of target lesion size measurements of up to 5 target lesions per patient were analyzed. Subjective image quality was evaluated for three readers independently utilizing 4- or 5-point Likert scales. Median radiation dose reduction was 46% using RD CT (P < 0.01). Median image noise across all measured tissue types was lower (P < 0.01) in RD CT. Subjective image quality for RD CT was higher (P < 0.01) in regard to image noise and overall image quality; however, there was no statistically significant difference regarding image sharpness (P = 0.59). There were subjectively more artifacts on RD CT (P < 0.01). Lesion conspicuity was subjectively better in RD CT (P < 0.01). Repeated target lesion size measurements were highly reproducible both on SD CT (ICC = 0.987) and RD CT (ICC = 0.97). RD CT imaging with MBIR provides diagnostic imaging quality and comparable lesion conspicuity on follow-up exams while allowing dose reduction by a median of 46% compared to SD CT imaging.
Pleiotropic effects of fenofibrate therapy on rats with hypertriglycemia.
Sun, Bing; Xie, Yuan; Jiang, Jinfa; Wang, Yiping; Xu, Xiaolin; Zhao, Cuimei; Huang, Feifei
2015-04-14
Cardio-protective effect of fibrate therapy is controversial and current research is to evaluate the effect of fenofibrate therapy on rats with hypertriglycemia. Rats with hypertriglycemia were produced by 10% fructose administration (10 ml daily) for 4 weeks. After model has been successfully produced as reflected by increased triglyceride level, different doses of fenofibrate, namely low dose (50 mg/kg body weight) and high dose (100 mg/kg body weight), were orally prescribed for 2 weeks. At baseline, 4 weeks of fructose administration and 2 weeks of fenofibrate therapy, parameters of interest were evaluated and compared. At baseline, no significant differences of parameter were observed between groups. After 4 weeks of fructose prescription, triglyceride level increased in company with high density lipoprotein cholesterol (HDL-C) and apoprotein A1 (ApoA1) decreased. C-reactive protein (CRP) and malondialdehyde (MDA) levels were also elevated. Endothelial function was impaired as reflected by reduced nitric oxide (NO) production and elevated serum asymmetric dimethylarginine (ADMA) level. All these changes were significant as compared to the control group (P<0.05), suggesting that short-term of triglyceride elevation could potently initiate atherosclerosis. With 2 weeks of fenofibrate therapy, in comparison to un-treated group, triglyceride level was significantly reduced in parallel with HDL-C and ApoA1 elevation. Inflammation and oxidation were also profoundly ameliorated as reflected by CRP and MDA reduction. Notably, NO production was enhanced in company with serum ADMA level decrease. Overall, these improvements manifested in a dose-dependent manner, which was supported by multivariate regression analysis showing that after adjusted to other variables, the dose of fenofibrate therapy remained significantly associated with NO production and serum ADMA level, with OR of 1.042 (high-dose versus low-dose, 95% CI 1.028-1.055, P<0.05). Fenofibrate therapy not only could reduce triglyceride level but also confer pleiotropic effects in terms of endothelium-protection and amelioration of inflammation and oxidation in a dose-dependent manner.
Paudel, Nava Raj; Shvydka, Diana; Parsai, E Ishmael
2016-09-08
Presence of interfaces between high and low atomic number (Z) materials, often encountered in diagnostic imaging and radiation therapy, leads to radiation dose perturbation. It is characterized by a very narrow region of sharp dose enhancement at the interface. A rapid falloff of dose enhancement over a very short distance from the interface makes the experimental dosimetry nontrivial. We use an in-house-built inexpensive thin-film Cadmium Telluride (CdTe) photodetector to study this effect at the gold-tissue interface and verify our experimental results with Monte Carlo (MC) modeling. Three-micron thick thin-film CdTe photodetectors were fabricated in our lab. One-, ten- or one hundred-micron thick gold foils placed in a tissue-equivalent-phantom were irradiated with a clinical Ir-192 high-dose-rate (HDR) source and current measured with a CdTe detector in each case was compared with the current measured for all uniform tissue-equivalent phantom. Percentage signal enhancement (PSE) due to each gold foil was then compared against MC modeled percentage dose enhancement (PDE), obtained from the geometry mimicking the experimental setup. The experimental PSEs due to 1, 10, and 100 μm thick gold foils at the closest measured distance of 12.5μm from the interface were 42.6 ± 10.8 , 137.0 ± 11.9, and 203.0 ± 15.4, respectively. The corresponding MC modeled PDEs were 38.1 ± 1, 164 ± 1, and 249 ± 1, respectively. The experimental and MC modeled values showed a closer agreement at the larger distances from the interface. The dose enhancement in the vicinity of gold-tissue interface was successfully measured using an in-house-built, high-resolution CdTe-based photodetector and validated with MC simulations. A close agreement between experimental and the MC modeled results shows that CdTe detector can be utilized for mapping interface dose distribution encountered in the application of ionizing radiation. © 2016 The Authors.
Kronenberg, Amy; Gauny, Stacey; Kwoh, Ely; Grossi, Gianfranco; Dan, Cristian; Grygoryev, Dmytro; Lasarev, Michael; Turker, Mitchell S
2013-05-01
Human exposure to high-energy protons occurs in space flight scenarios or, where necessary, during radiotherapy for cancer or benign conditions. However, few studies have assessed the mutagenic effectiveness of high-energy protons, which may contribute to cancer risk. Mutations cause cancer and most cancer-associated mutations occur at autosomal loci. This study addresses the cytotoxic and mutagenic effects of 1 GeV protons in mouse kidney epithelium. Mutant fractions were measured for an endogenous autosomal locus (Aprt) that detects all types of mutagenic events. Results for kidneys irradiated in vivo are compared with the results for kidney cells from the same strain exposed in vitro. The results demonstrate dose-dependent cell killing in vitro and for cells explanted 3-4 months postirradiation in vivo. Incubation in vivo for longer periods (8-9 months) further attenuates proton-induced cell killing. Protons are mutagenic to cells in vitro and for in vivo irradiated kidneys. The dose-response for Aprt mutation is curvilinear after in vitro or in vivo exposure, bending upward at the higher doses. While the absolute mutant fractions are higher in vivo, the fold-increase over background is similar for both in vitro and in situ exposures. Results are also presented for a limited study on the effect of dose fractionation on the induction of Aprt mutations in kidney epithelial cells. Dose-fractionation reduces the fraction of proton-induced Aprt mutants in vitro and in vivo and also results in less cell killing. Taken together, the mutation burden in the epithelium is slightly reduced by dose-fractionation. Autosomal mutations accumulated during clinical exposure to high-energy protons may contribute to the risk of treatment-associated neoplasms, thereby highlighting the need for rigorous treatment planning to reduce the dose to normal tissues. For low dose exposures that occur during most space flight scenarios, the mutagenic effects of protons appear to be modest.
Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.
Niedzielski, Joshua; Bluett, Jaques B; Williamson, Ryan T; Liao, Zhongxing; Gomez, Daniel R; Court, Laurence E
2013-07-08
We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three-dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm(3), respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans' mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm(3), respectively, compared with the clinical plans. The normalized plans' mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints.
Shilkrut, Mark; Merrick, Gregory S; McLaughlin, P William; Stenmark, Matthew H; Abu-Isa, Eyad; Vance, Sean M; Sandler, Howard M; Feng, Felix Y; Hamstra, Daniel A
2013-02-01
The objective of this study was to determine whether the addition of low-dose-rate brachytherapy or androgen-deprivation therapy (ADT) improves clinical outcome in patients with high-risk prostate cancer (HiRPCa) who received dose-escalated radiotherapy (RT). Between 1995 and 2010, 958 patients with HiRPCa were treated at Schiffler Cancer Center (n = 484) or at the University of Michigan (n = 474) by receiving either dose-escalated external-beam RT (EBRT) (n = 510; minimum prescription dose, 75 grays [Gy]; median dose, 78 Gy) or combined-modality RT (CMRT) consisting of (103) Pd implants (n = 369) or (125) I implants (n = 79) both with pelvic irradiation (median prescription dose, 45 Gy). The cumulative incidences of biochemical failure (BF) and prostate cancer-specific mortality (PCSM) were estimated by using the Kaplan-Meier method and Fine and Gray regression analysis. The median follow-up was 63.2 months (interquartile range, 35.4-99.0 months), and 250 patients were followed for >8 years. Compared with CMRT, patients who received EBRT had higher prostate-specific antigen levels, higher tumor classification, lower Gleason sum, and more frequent receipt of ADT for a longer duration. The 8-year incidence BF and PCSM among patients who received EBRT was 40% (standard error, 38%-44%) and 13% (standard error, 11%-15%) compared with 14% (standard error, 12%-16%; P < .0001) and 7% (standard error 6%-9%; P = .003) among patients who received CMRT. On multivariate analysis, the hazard ratios (HRs) for BF and PCSM were 0.35 (95% confidence interval [CI], 0.23-0.52; P < .0001) and 0.41 (95% CI, 0.23-0.75; P < .003), favoring CMRT. Increasing duration of ADT predicted decreased BF (P = .04) and PCSM (P = .001), which was greatest with long-term ADT (BF: HR, 0.33; P < .0001; 95% CI, 0.21-0.52; PCSM: HR, 0.30; P = .001; 95% CI, 0.15-0.6) even in the subgroup that received CMRT. In this retrospective comparison, both low-dose-rate brachytherapy boost and ADT were associated with decreased risks of BF and PCSM compared with EBRT. Copyright © 2012 American Cancer Society.
Yun, K L; Fann, J I; Sokoloff, M H; Fong, L G; Sarris, G E; Billingham, M E; Miller, D C
1991-01-01
With the advent of cyclosporin A, accelerated coronary arteriosclerosis has become the major impediment to the long-term survival of heart transplant recipients. Due to epidemiologic reports suggesting a salutary effect of fish oil, the dose response of fish oil on graft coronary arteriosclerosis in a rabbit heterotopic cardiac allograft model was assessed using safflower oil as a caloric control. Seven groups of New Zealand White rabbits (n = 10/group) received heterotropic heart transplants from Dutch-Belted donors and were immunosuppressed with low-dose cyclosporin A (7.5 mg/kg/day). Group 1 animals were fed a normal diet and served as control. Group 2, 3, and 4 animals received a daily supplement of low- (0.25 mL/kg/day), medium- (0.75 mL/kg/day), and high- (1.5 mL/kg/day) dose fish oil (116 mg n-3 polyunsaturated fatty acid/mL), respectively. Group 5, 6, and 7 animals were supplemented with equivalent dose of safflower oil (i.e., 0.25, 0.75, and 1.5 mL/kg/day). Oil-supplemented rabbits were pretreated for 3 weeks before transplantation and maintained on the same diet for 6 weeks after operation. The extent of graft coronary arteriosclerosis was quantified using computer-assisted, morphometric planimetry. When the animals were killed, cyclosporin A was associated with elevated plasma total cholesterol and triglyceride levels in the control group. While safflower oil prevented the increase in plasma lipids at all dosages, fish oil ameliorated the cyclosporin-induced increase in total cholesterol only with high doses. Compared to control animals, there was a trend for more graft vessel disease with increasing fish oil dose, as assessed by mean luminal occlusion and intimal thickness. A steeper trend was observed for increasing doses of safflower oil; compared to the high-dose safflower oil group, animals supplemented with low-dose safflower oil had less mean luminal occlusion (16.3% +/- 5.9% versus 41.4% +/- 7.6%, p less than 0.017) and intimal thickness (7.9 +/- 1.9 microns versus 34.0 +/- 13.0 microns, analysis of variance: p = 0.054). Low-dose safflower oil also had a slight, but nonsignificant, beneficial effect on graft vessel disease when compared to control rabbits. The same trends were observed in the degree of histologic rejection (0 = none to 3 = severe) in fish oil- and safflower oil-treated animals. Rejection score correlated weakly but significantly (p = 0.0001) with mean luminal occlusion (r = 0.52) and intimal thickness (r = 0.46). Therefore allograft coronary disease in this model appeared to exhibit an unfavorable, direct-dose response to fish oil and safflower oil, independent of effects on plasma lipids.(ABSTRACT TRUNCATED AT 400 WORDS) Images Fig. 2. PMID:1867523
Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude
2017-02-01
The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p range attainable at the prototype linac confirming the absence of any dose-rate dependence within the investigated range (7 × 10 3 to 8 × 10 6 Gy/s). This aspect was further corroborated by the linear relationship between the dose-per-pulse (D p ) measured by films and the charge per pulse (C p ) measured at the prototype linac exit. Our study shows that the use of EBT3 Gafchromic films can be extended to reference dosimetry in pulsed electron beams with a very high dose rate. The measurement results are associated with an overall uncertainty below 4% (k = 2) and are dose-rate and energy independent. © 2016 American Association of Physicists in Medicine.
Ibáñez, Lourdes; Diaz, Marta; Sebastiani, Giorgia; Sánchez-Infantes, David; Salvador, Cristina; Lopez-Bermejo, Abel; de Zegher, Francis
2011-11-01
The aim was to perform a first comparison between the effects of a classic therapy and those of a novel treatment for androgen excess in adolescent girls. We conducted a randomized, open-labeled trial at a university hospital. Thirty-four adolescents with hyperinsulinemic androgen excess and without risk of pregnancy participated in the study. Ethinyl estradiol-cyproterone acetate (EE-CA) vs. a low-dose combination of pioglitazone, flutamide, and metformin (PioFluMet) was administered for 6 months. We assessed hirsutism and acne scores; androgen excess; fasting insulin, lipid profile, C-reactive protein, high molecular-weight adiponectin, leptin, follistatin; carotid intima-media thickness; body composition (absorptiometry); and abdominal fat partitioning (magnetic resonance imaging). EE-CA and PioFluMet attenuated the androgen excess comparably but had divergent effects on fasting insulinemia; on circulating cholesterol, triglycerides, C-reactive protein, high molecular-weight adiponectin, leptin, and follistatin; on carotid intima-media thickness; on lean mass; and on abdominal, visceral, and hepatic fat, with all these divergences pointing to a healthier condition on low-dose PioFluMet. Low-dose PioFluMet compared favorably to EE-CA in adolescents with androgen excess and without pregnancy risk. The efficacy and safety of low-dose PioFluMet remain to be studied over a longer term and in larger cohorts.
[Suppression of VEGF protein expression by arctigenin in oral squamous cell carcinoma].
Pu, Guang-rui; Liu, Fa-yu; Wang, Bo
2015-08-01
To observe arctigenin's inhibitory effect on oral squamous cell carcinoma, and explore the possible mechanism. The expression of VEGF in 32 cases of oral squamous cell cancer and 20 adjacent tissue specimen were detected with immunohistochemistry. Human nude mouse transplantation tumor model of oral squamous cell cancer was prepared with HSC-3 cells line. Transplanted tumor growth and VEGF expression in transplanted tumor tissues were assayed after treatment with arctigenin. One-way ANOVA was used for comparison between groups with SPSS 16.0 software package. Compared with the adjacent tissue, immunohistochemical staining score of VEGF was significantly higher (P<0.01) in oral squamous cell carcinoma tissues. After treatment with arctigenin, the growth of oral squamous cell transplanted tumors in nude mouse was inhibited (P<0.05), and decreased weight in end point of observation was noted (P<0.05). There were significant differences between high dose group and low dose group (P<0.05). Compared with the nude mouse model group, the optical density of VEGF staining was significantly lower in arctigenin group (P<0.05). There were significant differences between high dose group and low dose group (P<0.05). Arctigenin can dose-dependently inhibit the growth of oral squamous cell carcinomas, and this effect may be related to down regulation of VEGF expression.
Zierhut, W; Studer, R; Laurent, D; Kästner, S; Allegrini, P; Whitebread, S; Cumin, F; Baum, H P; de Gasparo, M; Drexler, H
1996-05-01
Cardiac hypertrophy is associated with altered Ca2+ handling and may predispose to the development of LV dysfunction and cardiac failure. At the cellular level, the re-expression of ANF represents a well-established marker of myocyte hypertrophy while the decreased expression of the sarcoplasmatic reticulum (SR) Ca(2+)-ATPase is thought o play a crucial role in the alterations of Ca2+ handling and LV function. We assessed the dose-dependent effect of chronic ACE inhibition or AT1 receptor blockade on cardiac function in relation to the cardiac expression of the SR Ca(2+)-ATPase and ANF. Renal hypertensive rats (2K-1C) were treated for 12 weeks with three different doses of the ACE inhibitor benazepril, the AT1-receptor antagonist valsartan (each drug 0.3, 3, and 10 mg/kg per day i.p.) or placebo. LV dimensions, hypertrophy and wall stress were determined in vivo by magnetic resonance imaging and the gene expressions of ANF and SR Ca(2+)-ATPase were quantified by Northern blot. Low doses of both drugs did not affect blood pressure, hypertrophy, systolic wall stress and the ANF and SR Ca(2+)-ATPase gene expression. High doses of each drug reduced systolic blood pressure, wall stress, and LV hypertrophy to a similar extent and to values comparable to normotensive, age-matched rats. In addition, high dose treatment reduced LV end-systolic and end-diastolic volume as compared to untreated 2K-1C animals and normalized the mRNA levels of both ANF and SR Ca(2+)-ATPase (as compared to normotensive animals). We conclude that in this model, high doses of ACE inhibition and AT1-receptor blockade are necessary to normalize systolic blood pressure, LV hypertrophy and systolic LV wall stress which, in turn, is associated with restoration of a normal cardiac phenotype with respect to SR Ca(2+)-ATPase and ANF and normalization of cardiac function.
2012-01-01
Background In response to the short-term negative inotropic and chronotropic effects of β-blockers, heart failure (HF) guidelines recommend initiating β-blockers at low dose with gradual uptitration as tolerated to doses used in clinical trials. However, patterns and safety of β-blocker intensification in routine practice are poorly described. Methods We described β-blocker intensification among Kaiser Colorado enrollees with a primary discharge diagnosis of HF between 2001–2009. We then assessed β-blocker intensification in the 30 days prior to first hospital readmission for cases compared to the same time period following index hospitalization for non-rehospitalized matched controls. In separate analysis of the subgroup initiated on β-blocker after index hospital discharge, we compared adjusted rates of 30-day hospitalization following initiation of high versus low dose β-blocker. Results Among 3,227 patients, median age was 76 years and 37% had ejection fraction ≤40% (LVSD). During a median follow up of 669 days, 14% were never on β-blocker, 21% were initiated on β-blocker, 43% were discharged on β-blocker but never uptitrated, and 22% had discharge β-blocker uptitrated; 63% were readmitted and 49% died. β-blocker intensification occurred in the 30 days preceding readmission for 39 of 1,674 (2.3%) readmitted cases compared to 27 (1.6%) of matched controls (adjusted OR 1.36, 95% CI 0.81-2.27). Among patients initiated on therapy, readmission over the subsequent 30 days occurred in 6 of 155 (3.9%) prescribed high dose and 9 of 513 (1.8%) prescribed low dose β-blocker (adjusted OR 3.10, 95% CI 1.02-9.40). For the subgroup with LVSD, findings were not significantly different. Conclusion While β-blockers were intensified in nearly half of patients following hospital discharge and high starting dose was associated with increased readmission risk, the prevailing finding was that readmission events were rarely preceded by β-blocker intensification. These data suggest that β-blocker intensification is not a major precipitant of hospitalization, provided recommended dosing is followed. PMID:22709128
Lucy, J M; Peterson, M E; Randolph, J F; Scrivani, P V; Rishniw, M; Davignon, D L; Thompson, M S; Scarlett, J M
2017-03-01
Radioiodine ( 131 I) is effective treatment for hyperthyroidism in cats, but optimal dose to restore euthyroidism without inducing hypothyroidism is unclear. Treatment-induced hypothyroidism can lead to azotemia and reduced duration of survival. To compare efficacy and short-term outcomes of low-dose 131 I versus higher, standard-dose 131 I as treatment for hyperthyroidism. A total of 189 client-owned cats undergoing 131 I treatment for mild-to-moderate hyperthyroidism (serum T 4 ≥ 4.0 μg/dL and <13.0 μg/dL). Prospective, nonrandomized, cohort study comparing treatment with either low-dose (2 mCi, n = 150) or standard-dose (4 mCi, n = 39) 131 I. Serum T 4 , thyroid-stimulating hormone (TSH), and creatinine concentrations were measured after 1, 3, and 6 months to determine persistent hyperthyroidism, overt hypothyroidism (low T 4 , high TSH), subclinical hypothyroidism (normal T 4 , high TSH), and azotemia. There was no significant difference in prevalence of cats with persistent hyperthyroidism between standard- and low-dose treatment groups at 3 (0% versus 5.3%; P = .34) and 6 (0% versus 3.3%; P = .51) months. Overt (18% versus 1%; P = .0005) or subclinical (46% versus 21%; P = .004) hypothyroidism was more common in cats at 6 months after standard-dose 131 I. No difference in incidence of azotemia existed between groups, but cats treated with standard-dose 131 I had higher creatinine concentrations (P < .05) and higher percent rises in creatinine (P < .0001). Low-dose 131 I is safe and effective for cats with mild-to-moderate hyperthyroidism, as evidenced by a cure rate of >95% with reduced frequency of iatrogenic hypothyroidism and azotemia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing.
Tian, Z; Zhang, M; Hrycushko, B; Albuquerque, K; Jiang, S B; Jia, X
2016-01-01
Current clinical brachytherapy dose calculations are typically based on the Association of American Physicists in Medicine Task Group report 43 (TG-43) guidelines, which approximate patient geometry as an infinitely large water phantom. This ignores patient and applicator geometries and heterogeneities, causing dosimetric errors. Although Monte Carlo (MC) dose calculation is commonly recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This article presents our recent developments of a fast MC dose calculation package for high-dose-rate (HDR) brachytherapy, gBMC, built on a graphics processing unit (GPU) platform. gBMC-simulated photon transport in voxelized geometry with physics in (192)Ir HDR brachytherapy energy range considered. A phase-space file was used as a source model. GPU-based parallel computation was used to simultaneously transport multiple photons, one on a GPU thread. We validated gBMC by comparing the dose calculation results in water with that computed TG-43. We also studied heterogeneous phantom cases and a patient case and compared gBMC results with Acuros BV results. Radial dose function in water calculated by gBMC showed <0.6% relative difference from that of the TG-43 data. Difference in anisotropy function was <1%. In two heterogeneous slab phantoms and one shielded cylinder applicator case, average dose discrepancy between gBMC and Acuros BV was <0.87%. For a tandem and ovoid patient case, good agreement between gBMC and Acruos BV results was observed in both isodose lines and dose-volume histograms. In terms of the efficiency, it took ∼47.5 seconds for gBMC to reach 0.15% statistical uncertainty within the 5% isodose line for the patient case. The accuracy and efficiency of a new GPU-based MC dose calculation package, gBMC, for HDR brachytherapy make it attractive for clinical applications. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Schmitt, Paul J; Kelleher, John P; Ailon, Tamir; Heller, Joshua E; Kasliwal, Manish K; Shaffrey, Christopher I; Smith, Justin S
2016-08-01
Although use of very high-dose recombinant human bone morphogenetic protein-2 (rhBMP-2) has been reported to markedly improve fusion rates in adult spinal deformity (ASD) surgery, most centers use much lower doses due to cost constraints. How effective these lower doses are for fusion enhancement remains unclear. To assess fusion rates using relatively low-dose rhBMP-2 for ASD surgery. This was a retrospective review of consecutive ASD patients that underwent thoracic to sacral fusion. Patients that achieved 2-year follow-up were analyzed. Impact of patient and surgical factors on fusion rate was assessed, and fusion rates were compared with historical cohorts. Of 219 patients, 172 (78.5%) achieved 2-year follow-up and were analyzed. Using an average rhBMP-2 dose of 3.1 mg/level (average total dose = 35.9 mg/case), the 2-year fusion rate was 73.8%. Cancellous allograft, local autograft, and very limited iliac crest bone graft (<20 mL, obtained during iliac bolt placement) were also used. On multivariate analysis, female sex was associated with a higher fusion rate, whereas age, comorbidity score, deformity type, and 3-column osteotomy were not. There were no complications directly attributable to rhBMP-2. Fusion rates for ASD using low-dose rhBMP-2 were comparable to those reported for iliac crest bone graft but lower than for high-dose rhBMP-2. Importantly, there were substantial differences between patients in the present series and those in the historical comparison groups that could not be fully adjusted for based on available data. Prospective evaluation of rhBMP-2 dosing for ASD surgery is warranted to define the most appropriate dose that balances benefits, risks, and costs. ASD, adult spinal deformityICBG, iliac crest bone graftOR, odds ratiorhBMP-2, recombinant human bone morphogenetic protein-2RR, risk ratioTCO, 3-column osteotomy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.
2011-07-15
Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less
Efficacy of alternate day versus daily dosing of rosuvastatin
Dulay, Daisy; LaHaye, Stephen A; Lahey, Karen A; Day, Andrew G
2009-01-01
BACKGROUND: Compared with other statins, rosuvastatin has a relatively long half-life, which may allow for the administration of this medication on an alternate day basis. OBJECTIVE: To compare the efficacy of administering rosuvastatin on a daily basis versus on an alternate day basis for the treatment of dyslipidemia. METHODS: In the present crossover study, 45 patients with documented hypercholesterolemia requiring pharmacotherapy were administered either 20 mg of rosuvastatin on alternate days or 10 mg of rosuvastatin daily for six weeks. After a four-week washout period, patients were then switched to the other regimen for another six weeks. The primary end point was the percentage reduction of low-density lipoprotein cholesterol (LDL-C). RESULTS: LDL-C decreased by 48.5% versus 40.9% with daily and alternate day dosing, respectively. This represented an additional absolute reduction of LDL-C of 7.6% (95% CI 1.8% to 13.4%, P=0.012) with the daily dosing regimen. Both dosing regimens provided similar improvements in high-density lipoprotein cholesterol and triglycerides. CONCLUSIONS: Compared with alternate day dosing, daily dosing of rosuvastatin provides a statistically significant advantage in LDL-C reduction. However, the alternate day regimen may be a viable option for those patients in whom cost is a limitation to compliance. PMID:19214297
Mechanism of nonylphenol-induced neurotoxicity in F1 rats during sexual maturity.
Jie, Yu; Xuefeng, Yang; Mengxue, Yang; Xuesong, Yang; Jing, Yang; Yin, Tang; Jie, Xu
2016-06-01
The purpose of this study was to examine whether gestational and lactational exposure to environmental endocrine disrupting chemical, nonylphenol (NP), in pregnant dams would lead to the alterations in hormone levels in the body, apoptosis and glial fibrillary acidic protein (GFAP) in hippocampus during weaning and sexual maturity periods in pups of rats. Dams were gavaged with NP at dose levels of 25 mg/kg/day (low dose), 50 mg/kg/day (middle dose), 100 mg/kg/day (high dose) and groundnut oil alone (vehicle control) respectively from gestational day 6 to postnatal day (PND) 21. At PND 21, serum testosterone (TT) level significantly decreased in the 50, 100 mg/kg NP-treated groups compared with the control (p < 0.01). Serum estradiol (E2) level was increased with the increase in the NP concentration; a dose-effect relationship was revealed (r = 0.462, p < 0.01). At both PND 21 and PND 60, pups exposed to 100 mg/kg/day NP had an obviously higher apoptotic rate than control did. We observed a significant positive correlation between the dose of NP and the apoptotic rate (r = 0.836, p < 0.05). The number of GFAP-positive cells in rat hippocampus and integral optical density (IOD) of 100 mg/kg/day NP-treated group were much higher than the control group. GFAP mRNA expressions increased at high dose (100 mg/kg/day) (p < 0.05), and positive correlations between the GFAP mRNA expressions and NP level was observed (r = 0.586, 0.737, p < 0.05). Both the number of growth-associated protein (GAP)-43 positive cells and IOD were much lower at high dose (100 mg/kg/day) than the control at both PND 21 and PND 60 (p < 0.05). The number of GAP-43 positive cells was negatively correlated with the NP exposure dose (r = - 0.562, - 0.649, p < 0.05) at these two time points. GAP-43 mRNA expressions in the hippocampus of pups decreased dramatically at high dose (100 mg/kg/day) at both PND 21 and PND 60 compared with the control (p < 0.05). High exposure to NP might inhibit neuronal development and differentiation as indicated by the reduction of the neurotrophic factor GAP-43.
Lee, K W; Sheu, R J
2015-04-01
High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing (252)Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6_8 extended-range sphere versus the 6″ standard sphere). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Millan, M J; Colpaert, F C
1991-01-01
One day after intraplantar inoculation of Mycobacterium butyricum into the right hind-paw, unilaterally inflamed and control rats were implanted subcutaneously with osmotic mini-pumps delivering naloxone at 0.16 or 3.0 mg/kg/h or vehicle. As determined three days after implantation, 0.16 mg/kg/h of naloxone completely antagonized the antinociceptive action of the mu-agonist, morphine, but did not affect antinociception evoked by the kappa-agonist, U69,593. In contrast, at 3.0 mg/kg/h, naloxone blocked both morphine- and U69,593-induced antinociception. Thus, 0.16 mg/kg ("low dose") and 3.0 mg/kg ("high dose") of naloxone block mu, or mu- plus kappa-opioid receptors, respectively. Pumps were removed one week following their implantation. Inoculation was associated with a sustained hyperalgesia of the inflamed paw to noxious pressure, and elevation in resting core temperature, a loss of body weight, hypophagia, hypodipsia and a reduction in mobility. These parameters were differentially modified by the high as compared to the low dose of naloxone. Two days following implantation of pumps delivering the high dose of naloxone, the hyperalgesia of the inflamed paw was potentiated: by six days, this effect was lost. Further, one day after removal of pumps yielding the high dose, the inflamed paw showed a normalization of thresholds, that is a "rebound antinociception". One day later, this effect had subsided. In distinction, at no time did the low dose of naloxone modify nociceptive thresholds. The high dose of naloxone enhanced the reduction in body weight and food intake shown by unilaterally inflamed rats whereas the low dose was ineffective. Neither dose affected the reduction in water intake or hypothermia of unilaterally inflamed animals. The high dose of naloxone reduced the mobility of unilaterally inflamed rats whereas the low dose was ineffective. Finally, by 10 days following pump removal, pathology had transferred to the contralateral paw. In rats which had received the high but not the low dose, this transfer was blocked. It is concluded that blockade of kappa-opioid receptors with a high dose of naloxone experts pronounced functional effects in unilaterally inflamed rats. In distinction, selective blockade of mu-receptors with a low dose is ineffective. The changes seen include not only an enhancement of the hyperalgesia of the inflamed tissue, but also an exacerbation of variables (body weight, food intake and motility) which reflect pain states.(ABSTRACT TRUNCATED AT 400 WORDS)
Estimating systemic exposure to ethinyl estradiol from an oral contraceptive.
Westhoff, Carolyn L; Pike, Malcolm C; Tang, Rosalind; DiNapoli, Marianne N; Sull, Monica; Cremers, Serge
2015-05-01
This study was conducted to compare single-dose pharmacokinetics of ethinyl estradiol in an oral contraceptive with steady-state values and to assess whether any simpler measures could provide an adequate proxy of the "gold standard" 24-hour steady-state area under the curve (AUC) value. Identification of a simple, less expensive measure of systemic ethinyl estradiol exposure would be useful for larger studies that are designed to assess the relationship between an individual's ethinyl estradiol exposure and side-effects. We collected 13 samples over 24 hours for pharmacokinetic analysis on days 1 and 21 of the first cycle of a monophasic oral contraceptive that contained 30 μg ethinyl estradiol and 150 μg levonorgestrel in 17 nonobese healthy white women. We also conducted an abbreviated single-dose 9-sample pharmacokinetic analysis after a month washout. Ethinyl estradiol was measured by liquid chromatography-tandem mass spectrometry. We compared results of a full 13-sample steady-state pharmacokinetic analysis with results that had been calculated with the use of fewer samples (9 or 5) and after the single doses. We calculated Pearson correlation coefficients to evaluate the relationships between these estimates of systemic ethinyl estradiol exposure. The AUC, maximum, and 24-hour values were similar after the 2 single oral contraceptive doses (AUC; r=0.92). The steady-state 13-sample 24-hour AUC value was correlated highly with the average 9-sample AUC value after the 2 single doses (r=0.81; P=.0002). This correlation remained the same if the number of single-dose samples was reduced to 4, taken at time 1, 2.5, 4, and 24 hours. The 24-hour value at steady-state was correlated highly with the 24-hour steady-state AUC value (r=0.92; P<.0001). The average of the 24-hour values after the 2 single doses was also correlated quite highly with the steady-state AUC value (r=0.72; P=.0026). Limited blood sampling, including results from 2 single doses, gave highly correlated estimates of an oral contraceptive user's steady-state ethinyl estradiol exposure. Copyright © 2015 Elsevier Inc. All rights reserved.
Influence of 12C6+ ion irradiation on mutant avermitilis
NASA Astrophysics Data System (ADS)
Wang, Shu-Yang; Chen, Ji-Hong; Li, Wen-Jian; Liang, Jian-Ping; Bo, Yong-Heng; Ma, Xiao-Qi; Liu, Jing
2012-11-01
The effects of 12C+6 ion irradiation on colony morphology and mycelia morphology, as well as on mutation rate have been studied in the B1a high-product strains (ZJAV-Y1-203) mutated by heavy ion irradiation and compared with that in the original strain (ZJAV-A-1). After irradiating the rate of a straw hat colony type having a high ability of producing B1a in ZJAV-Y1-203 strains was higher than that found in ZJAV-A-1 strains. When strains were cultured in a liquid medium for 24 hours, the mycelium becoming thinner could be observed in all of the irradiated ZJAV- Y1-203 groups, but only in the ZJAV-A-1 groups irradiated at the dose of 50 Gy or more. The early growth of mycelium was inhibited in the ZJAV- Y1-203 group irradiated with a high dose. The highest positive mutation rate (23.5%) of ZJAV - Y1 - 203 was reached at the lower dose of 30 Gy while the highest positive mutation rate of 34.2% in ZJAV-A-1 appeared at 50 Gy. These results indicate that the effects of heavy ion irradiation still exist even in the mutated Streptomyces avermitilis, and only the dose is lower and the effects not so strong compared with the one that is first irradiated with optimized heavy ion doses. This is evidence of the one directional mutation being controlled by many more factors in a organism.
Dose-dependent effects of hydrocortisone infusion on autobiographical memory recall
Young, Kymberly; Drevets, Wayne C.; Schulkin, Jay; Erickson, Kristine
2011-01-01
The glucocorticoid hormone cortisol has been shown to impair episodic memory performance. The present study examined the effect of two doses of hydrocortisone (synthetic cortisol) administration on autobiographical memory retrieval. Healthy volunteers (n=66) were studied on two separate visits, during which they received placebo and either moderate-dose (0.15 mg/kg IV; n=33) or high-dose (0.45 mg/kg IV; n=33) hydrocortisone infusion. From 75 to 150 min post-infusion subjects performed an Autobiographical Memory Test and the California Verbal Learning Test (CVLT). The high-dose hydrocortisone administration reduced the percent of specific memories recalled (p = 0.04), increased the percent of categorical (nonspecific) memories recalled, and slowed response times for categorical memories (p <0.001), compared to placebo performance (p < 0.001). Under moderate-dose hydrocortisone the autobiographical memory performance did not change significantly with respect to percent of specific or categorical memories recalled or reaction times. Performance on the CVLT was not affected by hydrocortisone. These findings suggest that cortisol affects accessibility of autobiographical memories in a dose-dependent manner. Specifically, administration of hydrocortisone at doses analogous to those achieved under severe psychosocial stress impaired the specificity and speed of retrieval of autobiographical memories. PMID:21942435
Dumchev, Kostyantyn; Dvoryak, Sergii; Chernova, Olena; Morozova, Olga; Altice, Frederick L
2017-10-01
Opioid agonist treatments (OAT) are widely-used, evidence-based strategies for treating opioid dependence and reducing HIV transmission. The positive benefits of OAT are strongly correlated with time spent in treatment, making retention a key indicator for program quality. This study assessed patient retention and associated factors in Ukraine, where OAT was first introduced in 2004. Data from clinical records of 2916 patients enrolled in OAT at thirteen sites from 2005 to 2012 were entered into an electronic monitoring system. Survival analysis methods were used to determine the probability of retention and its correlates. Twelve-month retention was 65.8%, improving from 27.7% in 2005, to 70.9% in 2011. In multivariable analyses, the correlates of retention were receiving medium and high doses of medication (compared to low doses, dropout aHR=0.57 for both medium and high doses), having not been tested for HIV and tuberculosis (compared to not being tested, dropout aHR=4.44 and 3.34, respectively), and among those who were tested-a negative TB test result (compared to receiving a positive test result, dropout aHR=0.67). Retention in Ukrainian OAT programs, especially in recent years, is comparable to other countries. The results confirm the importance of adequate OAT dosing (≥60mg of methadone, ≥8mg of buprenorphine). Higher dosing, however, will require interventions that address negative attitudes toward OAT by patients and providers. Interruption of OAT, in the case developing tuberculosis, should incorporate continuity of OAT for TB patients through integrated care delivery systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Assessing The Impact Of Cancer Therapies On Ovarian Reserve
Gracia, Clarisa R.; Sammel, Mary D.; Freeman, Ellen; Prewitt, Maureen; Carlson, Claire; Ray, Anushree; Vance, Ashley; Ginsberg, Jill P.
2013-01-01
Objective To determine whether measures of ovarian reserve differ between females exposed to cancer therapies in a dose-dependent manner as compared to healthy controls of similar age and late-reproductive age. Design Cross-sectional analysis of data from a prospective cohort study Setting University Medical Center Patients 71 cancer survivors age 15-39; 67 healthy, similarly aged unexposed subjects; 69 regularly menstruating women of late-reproductive age (40-52 years). Interventions: None Main Outcome measures Early follicular phase hormones (FSH, Estradiol, Inhibin B, AMH) and ovarian ultrasound measurements (ovarian volume and Antral Follicle Counts) were compared using multivariable linear regression. Results In adjusted models, FSH, AMH and AFC differed between exposed vs. unexposed (FSH 11.12mIU/ml vs. 7.25mIU/ml, p=0.001; AMH 0.81ng/ml vs. 2.85ng/ml, p<0.001; AFC: 14.55 vs. 27.20, p<0.001. In participants with an FSH<10, survivors had lower levels of AMH and AFC compared to controls. Alkylating agent dose score was associated with increased levels of FSH (p= 0.016) and decreased levels of AMH (p=0.003). Exposure to pelvic radiation was associated with impairment in FSH, AMH, AFC and ovarian volume. AMH was similar in women previously exposed to high-dose cancer therapy and 40-42 year old controls. Conclusions Measures of ovarian reserve are impaired in a dose-dependent manner among cancer survivors compared to unexposed females of similar age. Reproductive hormone levels in menstruating survivors exposed to high-dose therapy are similar to late-reproductive women. The predictive value of measures for pregnancy and menopause must be studied. PMID:22137491
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurosawa, T; Moriya, S; Sato, M
2015-06-15
Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additionalmore » constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.« less
Volumetric Modulated Arc Radiotherapy for Vestibular Schwannomas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lagerwaard, Frank J.; Meijer, Otto W.M.; Hoorn, Elles A.P. van der
2009-06-01
Purpose: To evaluate volumetric modulated arc radiotherapy (RapidArc [RA]), a novel approach allowing for rapid treatment delivery, for the treatment of vestibular schwannoma (VS). Methods and Materials: The RA plans were generated for a small (0.5 cm{sup 3}), intermediate (2.8 cm{sup 3}), and large (14.8 cm{sup 3}) VS. The prescription dose was 12.5 Gy to the encompassing 80% isodose. The RA plans were compared with conventional radiosurgery plans using both a single dynamic conformal arc (1DCA) and five noncoplanar dynamic conformal arcs (5DCA). Conformity indices (CI) and dose-volume histograms of critical organs were compared. The RA plan for the medium-sizedmore » VS was measured in a phantom using Gafchromic EBT films and compared with calculated dose distributions. Results: The RA planning was completed within 30 min in all cases, and calculated treatment delivery time (after patient setup) was 5 min vs. 20 min for 5DCA. A superior CI was achieved with RA, with a substantial decrease in low-dose irradiation of the normal brain achieved relative to 5DCA plans. Maximum doses to critical organs were similar for RA and 5DCA but were higher for 1DCA. Film measurements showed the differences between calculated and measured doses to be smaller than 1.5% in the high-dose area and smaller than 3% in the low-dose area. Conclusion: The RA plans consistently achieved a higher CI and decrease in areas of low-dose irradiation. This, together with shorter treatment delivery times, has led to RA replacing our conventional five-arc radiosurgery technique for VS.« less
Manheimer, Eric D.; Peters, M. Robert; Wolff, Steven D.; Qureshi, Mehreen A.; Atluri, Prashanth; Pearson, Gregory D.N.; Einstein, Andrew J.
2011-01-01
Triple-rule-out computed tomography angiography (TRO CTA), performed to evaluate the coronary arteries, pulmonary arteries, and thoracic aorta, has been associated with high radiation exposure. Utilization of sequential scanning for coronary computed tomography angiography (CCTA) reduces radiation dose. The application of sequential scanning to TRO CTA is much less well defined. We analyzed radiation dose and image quality from TRO CTA performed in a single outpatient center, comparing scans from a period during which helical scanning with electrocardiographically controlled tube current modulation was used for all patients (n=35) and after adoption of a strategy incorporating sequential scanning whenever appropriate (n=35). Sequential scanning was able to be employed in 86% of cases. The sequential-if-appropriate strategy, compared to the helical-only strategy, was associated with a 61.6% dose decrease (mean dose-length product [DLP] of 439 mGy×cm vs 1144 mGy×cm and mean effective dose of 7.5 mSv vs 19.4 mSv, respectively, p<0.0001). Similarly, there was a 71.5% dose reduction among 30 patients scanned with the sequential protocol compared to 40 patients scanned with the helical protocol under either strategy (326 mGy×cm vs 1141 mGy×cm and 5.5 mSv vs 19.4 mSv, respectively, p<0.0001). Although image quality did not differ between strategies, there was a non-statistically significant trend towards better quality in the sequential protocol compared to the helical protocol. In conclusion, approaching TRO CTA with a diagnostic strategy of sequential scanning as appropriate offers a marked reduction in radiation dose while maintaining image quality. PMID:21306693
Carlos, Fernando; Gómez, Jorge Alberto; Anaya, Pablo; Romano-Mazzotti, Luis
2016-01-01
Hepatitis A virus (HAV) has shifted from high to intermediate endemicity in Mexico, which may increase the risk of clinically significant HAV infections in older children, adolescents and adults. The objective of this study was to evaluate the cost-utility of single-dose or 2-dose universal infant HAV vaccination strategy in Mexico, compared with no vaccination. A previously published dynamic model estimated the expected number of HAV cases with each strategy, and a decision model was used to estimate the costs and quality-adjusted life-years (QALYs) expected with each strategy. The time horizon was 25 years (2012–2036) and the base case analysis was conducted from the perspective of the Mexican public health system. Costs and QALYs after the first year were discounted at 5% annually. Input data were taken from national databases and published sources where available. The single-dose HAV vaccination strategy had an incremental cost-utility ratio (ICUR) of Mexican peso (MXN) 2,270 per QALY gained, compared with no vaccination. The two-dose strategy had an ICUR of MXN 14,961/QALY compared with no vaccination, and an ICUR of MXN 78,280/QALY compared with the single-dose strategy. The estimated ICURs were below the threshold of 1 x Mexican gross domestic product per capita. When indirect costs were included (societal perspective), the single-dose HAV vaccination strategy would be expected to improve health outcomes and to be cost-saving. This analysis indicates that routine vaccination of toddlers against HAV would be cost-effective in Mexico using either a single-dose or a 2-dose vaccination strategy. GSK study identifier: HO-12-12877. PMID:26503702
Carlos, Fernando; Gómez, Jorge Alberto; Anaya, Pablo; Romano-Mazzotti, Luis
2016-01-01
Hepatitis A virus (HAV) has shifted from high to intermediate endemicity in Mexico, which may increase the risk of clinically significant HAV infections in older children, adolescents and adults. The objective of this study was to evaluate the cost-utility of single-dose or 2-dose universal infant HAV vaccination strategy in Mexico, compared with no vaccination. A previously published dynamic model estimated the expected number of HAV cases with each strategy, and a decision model was used to estimate the costs and quality-adjusted life-years (QALYs) expected with each strategy. The time horizon was 25 years (2012-2036) and the base case analysis was conducted from the perspective of the Mexican public health system. Costs and QALYs after the first year were discounted at 5% annually. Input data were taken from national databases and published sources where available. The single-dose HAV vaccination strategy had an incremental cost-utility ratio (ICUR) of Mexican peso (MXN) 2,270 per QALY gained, compared with no vaccination. The two-dose strategy had an ICUR of MXN 14,961/QALY compared with no vaccination, and an ICUR of MXN 78,280/QALY compared with the single-dose strategy. The estimated ICURs were below the threshold of 1 x Mexican gross domestic product per capita. When indirect costs were included (societal perspective), the single-dose HAV vaccination strategy would be expected to improve health outcomes and to be cost-saving. This analysis indicates that routine vaccination of toddlers against HAV would be cost-effective in Mexico using either a single-dose or a 2-dose vaccination strategy. GSK study identifier: HO-12-12877.
Zaefarian, F; Romero, L F; Ravindran, V
2015-01-01
The effects of high dose of microbial phytase and an emulsifier on the performance, apparent metabolisable energy (AME) and nitrogen (N) retention in broilers fed on diets containing different fat sources were examined in a 5-week trial. Two fat sources (soy oil and tallow), two inclusion levels of E. coli phytase (500 or 1000 phytase units (FTU)/kg diet) and two inclusion levels of lysolecithin emulsifier (0 or 3.5 g/kg of diet) were evaluated in a 2 × 2 × 2 factorial arrangement of treatments. Throughout the 5-week trial, soy oil supplementation improved weight gain and feed per gain compared with tallow, but had no effect on feed intake. The high dose of phytase increased the weight gain and feed intake and lowered the feed per gain during d 1-21, but had no effect on performance parameters over the whole trial period. An effect of emulsifier was observed for feed intake during d 1-21 and over the whole trial period. Addition of emulsifier increased feed intake compared with diets without emulsifier. During weeks 1, 2, 3 and 5, birds fed on soy oil-based diets had higher nitrogen-corrected AME (AMEN) compared with those fed on tallow-based diets. During weeks 2, 3 and 5, the effect of phytase was significant for AMEN, with the high dose increasing the AMEN. During week 2, AMEN was increased with emulsifier addition. During weeks 1, 2, 3 and 5, birds fed on soy oil-based diets had higher fat retention compared with those fed on tallow-based diets. The high dose of phytase improved the retention of fat during week 5 and the addition of emulsifier resulted in higher fat retention during week 1. During weeks 2, 3 and 5, an interaction between fat source × phytase × emulsifier was observed for N retention. In soy oil-based diets, emulsifier plus 1000 FTU/kg phytase increased N retention compared with other groups, while in tallow-based diets, emulsifier addition increased N retention in diets with 500 FTU/kg, but not in 1000 FTU/kg diet. Overall, the present data suggest that the dietary fat source influenced performance, AMEN and fat retention in broiler chickens. There is opportunity to improve bird performance during d 1-21, AMEN and fat retention with higher doses of microbial phytase. Addition of the emulsifier increased the AMEN during week 2 and tract retention of fat during week 1, but this effect was not translated into improvements in performance.
High-dose phenobarbital or erythropoietin for the treatment of perinatal asphyxia in term newborns.
Avasiloaiei, Andreea; Dimitriu, Cristina; Moscalu, Mihaela; Paduraru, Luminita; Stamatin, Maria
2013-10-01
The aim of this study was to compare two neuroprotective strategies to supportive care in the treatment of perinatal asphyxia. A total of 67 term newborns with perinatal asphyxia were included and randomized into three groups: one group received supportive treatment; another group received a single dose of 40 mg/kg phenobarbital; and the third received three daily doses of 1000 IU/kg erythropoietin. The following parameters were analyzed: gestational age, birthweight, Apgar scores, cord blood pH, total serum antioxidant status (TAS), superoxide dismutase (SOD), glutathione peroxidase (GPx) and malondialdehyde (MDA). The newborns were included in the follow-up program and examined up to 18 months of age. TAS was higher in the erythropoietin group than in the other groups. SOD and GPx were lower for infants treated with phenobarbital or erythropoietin compared to control infants. MDA was lower in the erythropoietin group compared to the other groups, although the difference was not statistically significant (P > 0.05). The mortality rate was lower in the phenobarbital and erythropoietin groups (both 4.6%) than in the control group (17.4%). Long-term neurologic follow up showed a high incidence of sequelae in the control group compared to the phenobarbital and erythropoietin groups. Follow-up results were better in the phenobarbital group than in the erythropoietin group for motor and cognitive function at 3 and 6 months and worse for expressive language. At 18 months, however, the differences between these two groups were not significant. High-dose phenobarbital or erythropoietin along with supportive treatment has a positive influence on the outcome of newborns with perinatal asphyxia. Phenobarbital has the advantage of low cost and simplicity. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.
Lin, C-Y; Huang, W-Y; Jen, Y-M; Chen, C-M; Su, Y-F; Chao, H-L; Lin, C-S
2014-08-01
The aim of this study was to compare high-dose volumetric modulated arc therapy (VMAT) and fixed-field intensity-modulated radiotherapy (ff-IMRT) plans for the treatment of patients with middle-thoracic esophageal cancer. Eight patients with cT2-3N0M0 middle-thoracic esophageal cancer were enrolled. The treatment planning system was the version 9 of the Pinnacle(3) with SmartArc (Philips Healthcare, Fitchburg, WI, USA). VMAT and ff-IMRT treatment plans were generated for each case, and both techniques were used to deliver 50 Gy to the planning target volume (PTV(50)) and then provided a 16-Gy boost (PTV(66)). The VMAT plans provided superior PTV(66) coverage compared with the ff-IMRT plans (P = 0.034), whereas the ff-IMRT plans provided more appropriate dose homogeneity to the PTV(50) (P = 0.017). In the lung, the V(5) and V(10) were lower for the ff-IMRT plans than for the VMAT plans, whereas the V(20) was lower for the VMAT plans. The delivery time was significantly shorter for the VMAT plans than for the ff-IMRT plans (P = 0.012). In addition, the VMAT plans delivered fewer monitor units. The VMAT technique required a shorter planning time than the ff-IMRT technique (3.8 ± 0.8 hours vs. 5.4 ± 0.6 hours, P = 0.011). The major advantages of VMAT plans are higher efficiency and an approximately 50% reduction in delivery time compared with the ff-IMRT plans, with comparable plan quality. Further clinical investigations to evaluate the use of high-dose VMAT for the treatment of esophageal cancer are warranted. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
NASA Astrophysics Data System (ADS)
Chen, Liang-Kuang; Wu, Tung-Hsin; Yang, Ching-Ching; Tsai, Chia-Jung; Lee, Jason J. S.
2010-07-01
The aim of this study is to assess radiation dose and the corresponding image quality from suggested CT protocols which depends on different mean heart rate and high heart rate variability by using 256-slice CT. Fifty consecutive patients referred for a cardiac CT examination were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on a 256-slice CT scanner with one of five different protocols: retrospective ECG-gating (RGH) with full dose exposure in all R-R intervals (protocol A), RGH of 30-80% pulsing window with tube current modulation (B), RGH of 78±5% pulsing window with tube current modulation (C), prospective ECG-triggering (PGT) of 78% R-R interval with 5% padding window (D) and PGT of 78% R-R interval without padding window (E). Radiation dose parameters and image quality scoring were determined and compared. In this study, no significant differences were found in comparison on image quality of the five different protocols. Protocol A obtained the highest radiation dose comparing with those of protocols B, C, D and E by a factor of 1.6, 2.4, 2.5 and 4.3, respectively ( p<0.001), which were ranged between 2.7 and 11.8 mSv. The PGT could significantly reduce radiation dose delivered to patients, as compared to the RGH. However, the use of PGT has limitations and is only good in assessing cases with lower mean heart rate and stable heart rate variability. With higher mean heart rate and high heart rate variability circumstances, the RGH within 30-80% of R-R interval pulsing window is suggested as a feasible technique for assessing diagnostic performance.
The Effect of Ritalin on Response to Reward and Punishment in Children with ADHD.
ERIC Educational Resources Information Center
Arnett, Peter A.; And Others
1996-01-01
Groups of attention deficit hyperactivity disorder (ADHD) children taking a placebo, high dose, or low dose of Ritalin were compared in their responses to reward and punishment. Results suggest that Ritalin may improve the ability of ADHD children to withhold inappropriate responding by dampening their response to reward cues and, possibly, making…
Morain, P; Robin, J L; De Nanteuil, G; Jochemsen, R; Heidet, V; Guez, D
2000-01-01
Aims The aim of this study was to characterize the pharmacodynamics and the pharmacokinetics of S 17092, a new orally active prolyl endopeptidase inhibitor following single and repeated administration in elderly healthy volunteers. Methods This was a double-blind, randomized, placebo-controlled, single and multiple dose study in elderly healthy male and female volunteers (n = 36). Four doses were investigated in sequential order: 100, 400, 800 and 1200 mg. Each dose was administered orally once a day in single administration and then, after a 1 week washout period, during 7 days. Pharmacodynamics were assessed by measurement of plasmatic prolyl endopeptidase (PEP) activity, quantitative electroencephalogram (EEG) and psychometric tests. S 17092 concentrations in plasma were quantified by high performance liquid chromatography with tandem mass spectrometric detection. Results PEP activity in plasma was dose-dependently inhibited both after administration of a single dose and after repeated doses of S 17092. The mean maximal inhibition was obtained within 0.5–2 h after dosing, while inhibition lasted at least 12 h after dose administration. S 17092 appeared to be a centrally active substance as it induced statistically significant modifications in EEG compared with placebo. S 17092 at 100 mg exerted an acute increase in alpha band following single administration at 4 h and 8 h postdosing. When administered repeatedly over 7 days S 17092 did not appear to induce significant lasting central nervous system (CNS) effects. In psychometric tests, response times in the numeric working memory were significantly reduced compared with placebo, following the 800 mg dose. There were some beneficial residual effects of the 1200 mg dose on day 13: delayed word recall and word recognition sensitivity improved compared with the declines noted under placebo. Maximum measured concentration (Cmax) and area under the curve (AUC) parameters increased in proportion to the dose. The terminal half-life (t½) values ranged between 9 and 31 h on day 1 and between 7 and 18 h on day 14. A high interindividual variability was observed at all dose levels. S 17092 was well tolerated with no clinically significant changes in laboratory or physical parameters observed at any dose. Conclusions S 17092 had a potent, dose-dependent inhibitory effect on plasmatic PEP, increased alpha band EEG at the 100 mg dose and improved performance in two verbal memory tests at the 1200 mg dose while there were disruption to the vigilance task. The results obtained in elderly healthy subjects indicated that S 17092 is suitable for once-daily dosing without any serious adverse events. PMID:11012558
Lindh, Ingrid; Bråve, Andreas; Hallengärd, David; Hadad, Ronza; Kalbina, Irina; Strid, Åke; Andersson, Sören
2014-04-25
During early infection with human immunodeficiency virus type 1 (HIV-1), there is a rapid depletion of CD4(+) T-cells in the gut-associated lymphoid tissue (GALT) in the gastrointestinal tract. Therefore, immediate protection at these surfaces is of high priority for the development of an HIV-1 vaccine. Thus, transgenic plants expressing HIV-1 antigens, which are exposed to immune competent cells in the GALT during oral administration, can be interesting as potential vaccine candidates. In the present study, we used two HIV-1 p24 antigen-expressing transgenic plant systems, Arabidopsis thaliana and Daucus carota, in oral immunization experiments. Both transgenic plant systems showed a priming effect in mice and induced humoral immune responses, which could be detected as anti-p24-specific IgG in sera after an intramuscular p24 protein boost. Dose-dependent antigen analyses using transgenic A. thaliana indicated that low p24 antigen doses were superior to high p24 antigen doses. Copyright © 2014. Published by Elsevier Ltd.
Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy.
Hirata, Makoto; Monzen, Hajime; Tamura, Mikoto; Kubo, Kazuki; Matsumoto, Kenji; Hanaoka, Kohei; Okumura, Masahiko; Nishimura, Yasumasa
2018-05-01
Patient immobilization systems are used to establish a reproducible patient position relative to the couch. In this study, the impact of conventional lok-bars for CT-simulation (CIVCO-bar) and treatment (iBEAM-bar) were compared with a novel lok-bar (mHM-bar) in tomotherapy. Verification was obtained as follows: i. artifacts in CT images; ii. dose attenuation rate of lok-bar, compared to without lok-bar; and iii. dose differences between the calculated and measured absorbed doses. With the CIVCO-bar, there were obvious metal artifacts, while there were nearly no artifacts with the mHM-bar. The mean dose attenuation rates with the mHM-bar and iBEAM-bar were 1.31% and 2.28%, and the mean dose difference was 1.55% and 1.66% for mHM-bar and iBEAM-bar. Using the mHM-bar reduced artifacts on the CT image and improved dose attenuation are obtained. The lok-bar needs to be inserted as a structure set in treatment planning with tomotherapy. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Simulation of computed tomography dose based on voxel phantom
NASA Astrophysics Data System (ADS)
Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun
2017-01-01
Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.
Monte Carlo simulations to replace film dosimetry in IMRT verification.
Goetzfried, Thomas; Rickhey, Mark; Treutwein, Marius; Koelbl, Oliver; Bogner, Ludwig
2011-01-01
Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were recalculated by a pencil beam based treatment planning system (TPS) using an appropriate quality assurance (QA) phantom. All plans were verified both by film and diode dosimetry and compared to MC simulations. The irradiated films, the results of diode measurements and the computed dose distributions were evaluated, and the data were compared on the basis of gamma maps and dose-difference histograms. Average deviations in the high-dose region between diode measurements and point dose calculations performed with the TPS and MC program were 0.7 ± 2.7% and 1.2 ± 3.1%, respectively. For film measurements, the mean gamma values with 3% dose difference and 3mm distance-to-agreement were 0.74 ± 0.28 (TPS as reference) with dose deviations up to 10%. Corresponding values were significantly reduced to 0.34 ± 0.09 for MC dose calculation. The total time needed for both verification procedures is comparable, however, by far less labor intensive in the case of MC simulations. The presented study showed that independent dose calculation verification of IMRT plans with a fast MC program has the potential to eclipse film dosimetry more and more in the near future. Thus, the linac-specific QA part will necessarily become more important. In combination with MC simulations and due to the simple set-up, point-dose measurements for dosimetric plausibility checks are recommended at least in the IMRT introduction phase. Copyright © 2010. Published by Elsevier GmbH.
Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.
Rodbard, D
1988-10-01
The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.
A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik
2012-01-01
Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.
Protein substitute dosage in PKU: how much do young patients need?
MacDonald, A; Chakrapani, A; Hendriksz, C; Daly, A; Davies, P; Asplin, D; Hall, K; Booth, I W
2006-07-01
The optimal dose of protein substitute has not been determined in children with phenylketonuria (PKU). To determine if a lower dose of protein substitute could achieve the same or better degree of blood phenylalanine control when compared to the dosage recommended by the UK MRC.(1) In a six week randomised, crossover study, two doses of protein substitute (Protocol A: 2 g/kg/day of protein equivalent; Protocol B: 1.2 g/kg/day protein equivalent) were compared in 25 children with well controlled PKU aged 2-10 years (median 6 years). Each dose of protein substitute was taken for 14 days, with a 14 day washout period in between. Twice daily blood samples (fasting pre-breakfast and evening, at standard times) for plasma phenylalanine were taken on day 8-14 of each protocol. The median usual dose of protein substitute was 2.2 g/kg/day (range 1.5-3.1 g/kg/day). When compared with control values, median plasma phenylalanine on the low dose of protein substitute increased at pre-breakfast by 301 mumol/l (95% CI 215 to 386) and in the evening by 337 micromol/l (95% CI 248 to 431). On the high dose of protein substitute, plasma phenylalanine concentrations remained unchanged when compared to control values. However, wide variability was seen between subjects. A higher dosage of protein substitute appeared to contribute to lower blood phenylalanine concentrations in PKU, but it did have a variable and individual impact and may have been influenced by the carbohydrate (+/- fat) content of the protein substitute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sangroh; Yoo, Sua; Yin Fangfang
2010-07-15
Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dosemore » thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.« less
Szymusiak, Magdalena; Hu, Xiaoyu; Leon Plata, Paola A; Ciupinski, Paulina; Wang, Zaijie Jim; Liu, Ying
2016-09-10
Curcumin is a bioactive molecule extracted from Turmeric roots that has been recognized to possess a wide variety of important biological activities. Despite its great pharmacological activities, curcumin is highly hydrophobic, which results in poor bioavailability. We have formulated this hydrophobic compound into stable polymeric nanoparticles (nano-curcumin) to enhance its oral absorption. Pharmacokinetic analysis after oral delivery of nano-curcumin in mice demonstrated approximately 20-fold reduction in dose requirement when compared to unformulated curcumin to achieve comparable plasma and central nervous system (CNS) tissue concentrations. This investigation corroborated our previous study of curcumin functionality of attenuating opioid tolerance and dependence, which shows equivalent efficacy of low-dose (20mg/kg) nano-curcumin and high-dose (400mg/kg) pure curcumin in mice. Furthermore, the highly selective and validated liquid chromatography-mass spectrometry (LC-MS) method was developed to quantify curcumin glucuronide, the major metabolite of curcumin. The results suggest that the presence of curcumin in the CNS is essential for prevention and reversal of opioid tolerance and dependence. Copyright © 2016 Elsevier B.V. All rights reserved.
[Mechanism of leukocytapheresis effect in the treatment of ulcerative colitis].
Sawada, K; Ohnishi, K; Fukunaga, K; Chikano, S; Egashira, A; Satomi, M; Shimoyama, T
1999-12-01
To solve adverse effects of high dose steroid administration for patients with moderately severe and severe ulcerative colitis (UC), additional use of leukocytapheresis (LCAP) was tried to settle colonic inflammation. We evaluated immunological changes in the treatment of LCAP using leukocyte removal filter for UC patients. We then assessed the clinical effectiveness of LCAP compared with that of high dose of steroid therapy. LCAP removed monocytes, granulocytes, and lymphocytes presenting CD 11 b+, CD 11 c+, and HLADR+, selectively from the patients. Proinflammatory cytokine productions measured such as TNF alpha, IL-1 beta, and IL 8 reduced and IL 10 increased immediately after LCAP compared with before perfusion. Improved rate was about 70% for LCAP group and about 40% for high dose steroid group (Refer J Gastroenterol). Selective removal of granulocyte, monocytes, and activated lymphocytes inhibits proinflammatory cytokine production and increases immune modulating cytokine productions (Refer Therapeutic Apheresis). Then quick inhibition of several inflammatory deteriorated factors simultaneously controls the activity and clinical symptoms of UC with less severe adverse effects. It can be considered one option for treatment of UC.
Svanberg, A; Ohrn, K; Birgegård, G
2012-11-01
We have previously published a randomised controlled study of the efficacy of cryotherapy in preventing acute oral mucositis after high-dose chemotherapy for stem cell transplantation. The present study is a 5-year follow-up safety study of survival in these patients. In the previously published study oral cryotherapy (cooling of the oral cavity) during high-dose chemotherapy significantly reduced mucositis grade and opiate use in the treated group. All patients were followed up for at least 5 years with regard to relapse and death rates. Baseline data, transplant complications and mucositis data were compared. Significantly more patients (25/39) who received oral cryotherapy were alive after 5 years compared to 15/39 in the control group (P= 0.025). Relapse rates were similar. The only baseline difference was a lower proportion of patients in complete remission at transplantation in the control group (6 vs. 13, P= 0.047). This 5-year follow-up study gave no support for safety concerns with cryotherapy. © 2012 Blackwell Publishing Ltd.
Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration
NASA Astrophysics Data System (ADS)
Bernatowicz, Kinga; Geets, Xavier; Barragan, Ana; Janssens, Guillaume; Souris, Kevin; Sterpin, Edmond
2018-04-01
Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5 min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.
Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-01-01
Introduction Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. Materials and Methods A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Results Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13–53.8% reduction in low dose protocol. Conclusion The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose. PMID:27437322