Ohlson, Blake L; Shatby, Meena W; Parks, Brent G; White, Kacey L; Schon, Lew C
2011-02-01
Augmented retrograde intramedullary (IM) nail fixation was compared with augmented periarticular locking- plate fixation for tibiotalocalcaneal arthrodesis. Specimens in 10 matched pairs were randomly assigned to a fixation construct and loaded cyclically in dorsiflexion. The groups did not differ in initial or final stiffness, load to failure, or construct deformation. No correlation was found between bone mineral density and construct deformation for either group. A humeral locking plate may be a viable alternative to an IM nail for tibiotalocalcaneal fixation in cases not amenable to IM nailing.
Mulligan, Ryan P; Adams, Samuel B; Easley, Mark E; DeOrio, James K; Nunley, James A
2017-12-01
A variety of operative approaches and fixation techniques have been described for tibiotalocalcaneal (TTC) arthrodesis. The intramedullary (IM) nail and lateral, fixed-angle plating are commonly used because of ease of use and favorable biomechanical properties. A lateral, transfibular (LTF) approach allows for direct access to the tibiotalar and subtalar joints, but the posterior, Achilles tendon-splitting (PATS) approach offers a robust soft tissue envelope. The purpose of this study was to compare the results of TTC arthrodesis with either a PATS approach with IM nailing or LTF approach with fixed-angle plating. A retrospective review was performed on all patients who underwent simultaneous TTC arthrodesis with minimum 1 year clinical and radiographic follow up. Patients were excluded if they underwent TTC arthrodesis through an approach other than PATS or LTF, and received fixation without an IM nail or fixed-angle plate. Primary outcomes examined were union rate, revisions, and complications. Thirty-eight patients underwent TTC arthrodesis with a PATS approach and IM nailing, and 28 with a LTF approach and lateral plating. The overall union rate was 71%; 76% (29 of 38 patients) for the PATS/IM nail group, and 64% (18 of 28) for LTF/plating group ( P = .41). Symptomatic nonunion requiring revision arthrodesis occurred in 16% (6 of 38) of the PATS/IM nail group versus 7% (2 of 28) in the LTF/lateral plating group ( P = .45). There were no significant differences in individual tibiotalar or subtalar union rates, superficial wound problems, infection, symptomatic hardware, stress fractures, or nerve irritations. Union, revision, and complication rates were similar for TTC arthrodesis performed with a PATS approach and IM nail compared with an LTF approach and fixed-angle plate in a complex patient population. Both techniques were adequate, especially when prior incisions, preexisting hardware, or deformity preclude options. Level III, retrospective comparative study.
Andrzejewski, Krzysztof; Panasiuk, Michał; Grzegorzewski, Andrzej; Synder, Marek
2013-10-31
BACKGROUND. Despite extensive current knowledge about fractures of the femoral shaft, the choice between antegrade and retrograde intramedullary (IM) nailing with respect to the future function of the joint serving to introduce the nail continues to raise controversy. To compare knee function in patients with a healed fracture of the femoral shaft fixed by antegrade vs. retrograde IM nailing. MATERIAL AND METHODS. The study involved a group of 65 individuals with traumatic fractures of the femoral shaft who underwent stabilisation with IM nails in the years 2001-2010. Thirty-two cases were retrograde nails (Group R) and 33 antegrade nails (Group A). Patient age at trauma ranged from 19 to 91 years (mean: 47). Knee function was assessed in both groups with the KOOS, KSS1 and KSS2 scoring systems. RESULTS. Knee function as assessed with KOOS differed significantly between retrograde and antegrade nailing, with a greater incidence of poor and fair results in the former and more excellent outcomes in the latter group (p=0.0133). As regards KSS1 and KSS2, there were no significant differences between the groups (p=0.1947, p=0.4038). The range of motion was 86-125 degrees in Group R and 121-125 degrees in Group A. Knee pain was reported by 37.5% of the patients treated with retrograde nailing and 39.4% of those who had the IM nail inserted via the antegrade approach (p=0.22). The mean time to bone union was 180 days in Group R and 219 days in Group A (p=0.25). Age and presence of osteoarthritis at trauma significantly lowered the KOOS (p=0.0027, p= 0.005) and KSS (p=0.0002, p=0.002) scores, as well as the knee range of motion (p=0.0014, p=0.004) CONCLUSIONS. 1. Knee function following retrograde and antegrade IM nailing to stabilise femoral shaft fractures was comparable. 2. The choice of IM nailing method should not be based solely on orthopaedic indications, but also on the severity of osteoarthritis present at trauma.
Mückley, Thomas; Eichorn, Stephan; Hoffmeier, Konrad; von Oldenburg, Geert; Speitling, Andreas; Hoffmann, Gunther O; Bühren, Volker
2007-02-01
Intramedullary implants are being used with increasing frequency for tibiotalocalcaneal fusion (TTCF). Clinically, the question arises whether intramedullary (IM) nails should have a compression mode to enhance biomechanical stiffness and fusion-site compression. This biomechanical study compared the primary stability of TTCF constructs using compressed and uncompressed retrograde IM nails and a screw technique in a bone model. For each technique, three composite bone models were used. The implants were a Biomet nail (static locking mode and compressed mode), a T2 femoral nail (compressed mode); a prototype IM nail 1 (PT1, compressed mode), a prototype IM nail 2 (PT2, dynamic locking mode and compressed mode), and a three-screw construct. The compressed contact surface of each construct was measured with pressure-sensitive film and expressed as percent of the available fusion-site area. Stiffness was tested in dorsiflexion and plantarflexion (D/P), varus and valgus (V/V), and internal rotation and external rotation (I/E) (20 load cycles per loading mode). Mean contact surfaces were 84.0 +/- 6.0% for the Biomet nail, 84.0 +/- 13.0% for the T2 nail, 70.0 +/- 7.2% for the PTI nail, and 83.5 +/- 5.5% for the compressed PT2 nail. The greatest primary stiffness in D/P was obtained with the compressed PT2, followed by the compressed Biomet nail. The dynamically locked PT2 produced the least primary stiffness. In V/V, PT1 had the (significantly) greatest primary stiffness, followed by the compressed PT2. The statically locked Biomet nail and the dynamically locked PT2 had the least primary stiffness in V/V. In I/E, the compressed PT2 had the greatest primary stiffness, followed by the PT1 and the T2 nails, which did not differ significantly from each other. The dynamically locked PT2 produced the least primary stiffness. The screw construct's contact surface and stiffness were intermediate. The IM nails with compression used for TTCF produced good contact surfaces and primary stiffness. They were significantly superior in these respects to the uncompressed nails and the screw construct. The large contact surfaces and great primary stiffness provided by the IM nails in a bone model may translate into improved union rates in patients who have TTCF.
Zhang, Ke-xue; Zhao, Jing-xin; Zhao, Zhe; Ng, Li-cheng; Su, Xiu-yun; Long, An-hua; Mao, Zhi; Zhang, Jin-hui; Zhang, Li-hai; Tang, Pei-fu
2015-05-01
TFo compare the efficacy and complications rate of intramedullary (IM) nailing or K-wire versus plating fixation for clavicular fractures. Pubmed, Embase, Cochrane Library databases, CNKI, VIP and Wangfang databases were searched to find all randomized or quasi-randomized controlled trials of clavicle fractures using plating versus IM nailing or K-wire. The methodologic quality of the studies was assessed. After independent study selection by 2 authors ,data were collected and extracted independently. Outcomes of postoperative shoulder functional measurement, the efficacy and information of the operation and complications rate were meta-analyzed using RevMan 5 software. Nine hundreds and seventy-six patients in 10 randomized controlled trials (RCTs) and 3 quasi-RCTs were involved in the meta-analysis,of which 5 studies compared the K-wire and the plating fixations and 8 studies compared the IM nailing and the plating fixations. The overall odds ratio(OR) (with 95% CI) of the operation efficacy for K-wire versus the plating was 3.79 (1.93, 7.46). The overall weighted mean difference (with 95% CI) of Constant Shoulder score for plating versus IM fixation was -1.39 (-3.43, 0.65) in 6 studies. The overall OR of the plating versus IM nailing was 9.34(2.70, 32.32) for the overall major complications in 5 studies and 5.04 (1.52,16.77) for the revision rate in 5 studies. The current limited evidences suggested that the IM fixation could reduce the incidences of the overall major complications and the revision surgery, while the post-operative efficacy of the plating was superior to the K-wire. More high quality RCTs are still needed in the future.
Iacono, Francesco; Francesco, Iacono; Raspugli, Giovanni Francesco; Francesco, Raspugli Giovanni; Bruni, Danilo; Danilo, Bruni; Lo Presti, Mirco; Mirco, Lo Presti; Sharma, Bharat; Bharat, Sharma; Akkawi, Ibrahim; Ibrahim, Akkawi; Marcacci, Maurilio; Maurilio, Marcacci
2013-10-01
Infection after revision total knee arthroplasty (TKA) for previous septic TKA can be a challenging problem to treat due to loss of bone stock and soft tissue integrity. In these cases, arthrodesis is a well-recognized salvage procedure. The aim of this retrospective study was to compare the results as described by a Visual Analogue Scale (VAS) and the Lequesne Algofunctional Score (LAS) of knee arthrodeses performed by using either an external fixator (EF) or an intramedullary nail (IM). The study included 34 knee arthrodesis divided in two groups: first group included 12 patients treated with EF and the second group of 22 patients dealt with IM nail. Clinical and functional evaluation was performed using the VAS and the LAS. Full-length radiographs were used to verify limb length discrepancy. VAS and LAS results showed a substantial improvement relative to preoperative condition in both groups. However, the LAS was significantly better in the IM nail group. The mean leg length discrepancy was significantly greater (4.5 cm) in the first group than in the second one (0.8 cm). No recurrence of infection was observed in the EF group while there were three recurrent infections in the IM nail group. Our study supported the existing literature and found that reinfection after revision TKA can be effectively treated with arthrodesis. In presence of massive bone loss, we recommend arthrodesis with IM nail used as an endoprosthesis, without bone-on-bone fusion, to produce a stable and painless knee, while preserving the limb length. Use of an IM nail allowed us to get a better functional result than EF.
Mao, Zhi; Wang, Guoqi; Zhang, Lihai; Zhang, Licheng; Chen, Shuo; Du, Hailong; Zhao, Yanpeng; Tang, Peifu
2015-06-16
The choice between intramedullary (IM) nailing or plating of distal tibia fractures without articular involvement remains controversial. A meta-analysis of randomized controlled trials (RCTs) and observational studies was performed to compare IM nailing with plating for distal tibia fractures without articular involvement and to determine the dominant strategy. The PubMed, Embase, Cochrane Library databases, Chinese Wan-Fang Database, and China National Knowledge Infrastructure were searched. Twenty-eight studies, which included 1863 fractures, met the eligible criteria. The meta-analysis did not identify a statistically significant difference between the two treatments in terms of the rate of deep infection, delayed union, removal of instrumentation, or secondary procedures either in the RCT or retrospective subgroups. IM nailing was associated with significantly more malunion events and a higher incidence of knee pain in the retrospective subgroup and across all the studies, but not significantly in the RCT subgroup, and a lower rate of delayed wound healing and superficial infection both in the RCT and retrospective subgroups relative to plating. A meta-analysis of the functional scores or questionnaires was not possible because of the considerable variation among the included studies, and no significant differences were observed. Evidence suggests that both IM nailing and plating are appropriate treatments as IM nailing shows lower rate of delayed wound healing and superficial infection and plating may avoid malunion and knee pain. These findings should be interpreted with caution, however, because of the heterogeneity of the study designs. Large, rigorous RCTs are required.
Pseudoelastic intramedullary nailing for tibio-talo-calcaneal arthrodesis.
Yakacki, Christopher M; Gall, Ken; Dirschl, Douglas R; Pacaccio, Douglas J
2011-03-01
Tibio-talo-calcaneal (TTC) arthrodesis is a procedure to treat severe ankle arthropathy by providing a pain-free and stable fusion. Intramedullary (IM) nails offer a method of internal fixation for TTC arthrodesis by providing compressive stability, as well as shear and torsional rigidity. IM nails have been developed to apply compression to the TTC complex during installation; however, current designs are highly susceptible to a loss of compression when exposed to small amounts of bone resorption and cyclic loading. Nickel titanium (NiTi) is a shape-memory alloy capable of recovering large amounts of deformation via shape-memory or pseudoelasticity. Currently, the next generation of IM nails is being developed to utilize the adaptive, pseudoelastic properties of NiTi and provide a fusion nail that is resistant to loss of compression or loosening. Specifically, the pseudoelastic IM nail contains an internal NiTi compression element that applies sustained compression during the course of fusion, analogous to external fixators. © 2011 Expert Reviews Ltd
Costa, Matthew L; Achten, Juul; Hennings, Susie; Boota, Nafisa; Griffin, James; Petrou, Stavros; Maredza, Mandy; Dritsaki, Melina; Wood, Thomas; Masters, James; Pallister, Ian; Lamb, Sarah E; Parsons, Nick R
2018-05-01
The best treatment for fractures of the distal tibia remains controversial. Most of these fractures require surgical fixation, but the outcomes are unpredictable and complications are common. To assess disability, quality of life, complications and resource use in patients treated with intramedullary (IM) nail fixation versus locking plate fixation in the 12 months following a fracture of the distal tibia. This was a multicentre randomised trial. The trial was conducted in 28 UK acute trauma centres from April 2013 to final follow-up in February 2017. In total, 321 adult patients were recruited. Participants were excluded if they had open fractures, fractures involving the ankle joint, contraindication to nailing or inability to complete questionnaires. IM nail fixation ( n = 161), in which a metal rod is inserted into the hollow centre of the tibia, versus locking plate fixation ( n = 160), in which a plate is attached to the surface of the tibia with fixed-angle screws. The primary outcome measure was the Disability Rating Index (DRI) score, which ranges from 0 points (no disability) to 100 points (complete disability), at 6 months with a minimum clinically important difference of 8 points. The DRI score was also collected at 3 and 12 months. The secondary outcomes were the Olerud-Molander Ankle Score (OMAS), quality of life as measured using EuroQol-5 Dimensions (EQ-5D), complications such as infection, and further surgery. Resource use was collected to inform the health economic evaluation. Participants had a mean age of 45 years (standard deviation 16.2 years), were predominantly male (61%, 197/321) and had experienced traumatic injury after a fall (69%, 223/321). There was no statistically significant difference in DRI score at 6 months [IM nail fixation group, mean 29.8 points, 95% confidence interval (CI) 26.1 to 33.7 points; locking plate group, mean 33.8 points, 95% CI 29.7 to 37.9 points; adjusted difference, 4.0 points, 95% CI -1.0 to 9.0 points; p = 0.11]. There was a statistically significant difference in DRI score at 3 months in favour of IM nail fixation (IM nail fixation group, mean 44.2 points, 95% CI 40.8 to 47.6 points; locking plate group, mean 52.6 points, 95% CI 49.3 to 55.9 points; adjusted difference 8.8 points, 95% CI 4.3 to 13.2 points; p < 0.001), but not at 12 months (IM nail fixation group, mean 23.1 points, 95% CI 18.9 to 27.2 points; locking plate group, 24.0 points, 95% CI 19.7 to 28.3 points; adjusted difference 1.9 points, 95% CI -3.2 to 6.9 points; p = 0.47). Secondary outcomes showed the same pattern, including a statistically significant difference in mean OMAS and EQ-5D scores at 3 and 6 months in favour of IM nail fixation. There were no statistically significant differences in complications, including the number of postoperative infections (13% in the locking plate group and 9% in the IM nail fixation group). Further surgery was more common in the locking plate group (12% in locking plate group and 8% in IM nail fixation group at 12 months). The economic evaluation showed that IM nail fixation provided a slightly higher quality of life in the 12 months after injury and at lower cost and, therefore, it was cost-effective compared with locking plate fixation. The probability of cost-effectiveness for IM nail fixation exceeded 90%, regardless of the value of the cost-effectiveness threshold. As wound dressings after surgery are clearly visible, it was not possible to blind the patients to their treatment allocation. This evidence does not apply to intra-articular (pilon) fractures of the distal tibia. Among adults with an acute fracture of the distal tibia who were randomised to IM nail fixation or locking plate fixation, there were similar disability ratings at 6 months. However, recovery across all outcomes was faster in the IM nail fixation group and costs were lower. The potential benefit of IM nail fixation in several other fractures requires investigation. Research is also required into the role of adjuvant treatment and different rehabilitation strategies to accelerate recovery following a fracture of the tibia and other long-bone fractures in the lower limb. The patients in this trial will remain in longer-term follow-up. Current Controlled Trials ISRCTN99771224 and UKCRN 13761. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 22, No. 25. See the NIHR Journals Library website for further project information.
NASA Astrophysics Data System (ADS)
Esfandiari, H.; Amiri, S.; Lichti, D. D.; Anglin, C.
2014-06-01
A C-arm is a mobile X-ray device that is frequently used during orthopaedic surgeries. It consists of a semi-circular, arc-shaped arm that holds an X-ray transmitter at one end and an X-ray detector at the other. Intramedullary nail (IM nail) fixation is a popular orthopaedic surgery in which a metallic rod is placed into the patient's fractured bone (femur or tibia) and fixed using metal screws. The main challenge of IM-nail fixation surgery is to achieve the X-ray shot in which the distal holes of the IM nail appear as circles (desired view) so that the surgeon can easily insert the screws. Although C-arm X-ray devices are routinely used in IM-nail fixation surgeries, the surgeons or radiation technologists (rad-techs) usually use it in a trial-and-error manner. This method raises both radiation exposure and surgery time. In this study, we have designed and developed an IM-nail distal locking navigation technique that leads to more accurate and faster screw placement with a lower radiation dose and a minimum number of added steps to the operation to make it more accepted within the orthopaedic community. The specific purpose of this study was to develop and validate an automated technique for identifying the current pose of the IM nail relative to the C-arm. An accuracy assessment was performed to test the reliability of the navigation results. Translational accuracy was demonstrated to be better than 1 mm, roll and pitch rotations better than 2° and yaw rotational accuracy better than 2-5° depending on the separate angle. Computation time was less than 3.5 seconds.
Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R
2016-06-01
Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate constructs and the unlocked IM nail were significantly less with a 50% saw cut depth. Plate fixation was superior to IM nail fixation in limiting the opening of a simulated midtibial stress fracture, and anterior-posterior placement of the plate was an important variable for this construct. Results from these tests can help guide the selection of fixation hardware for patients requiring surgical treatment for a midtibial stress fracture. © 2016 The Author(s).
Makridis, Kostas G; Tosounidis, Theodoros; Giannoudis, Peter V
2013-01-01
Implant related sepsis is a relatively unusual complication of intra-medullary nail fixation of long bone fractures. Depending on the extent of infection, timing of diagnosis and progress of fracture union, different treatment strategies have been developed. The aim of this review article is to collect and analyze the existing evidence about the incidence and management of infection following IM nailing of long bone fractures and to recommend treatment algorithms that could be valuable in everyday clinical practice. After searching the P u b M e d /Medline databases, 1270 articles were found related to the topic during the last 20 years. The final review included 28 articles that fulfilled the inclusion criteria. Only a few prospective studies exist to report on the management of infection following IM nailing of long-bone fractures. In general, stage I (early) infections only require antibiotic administration with/without debridement. Stage II (delayed) infections can be successfully treated with debridement, IM reaming, antibiotic nails, and administration of antibiotics. Infected non-unions are best treated with exchange nailing, antibiotic administration and when infection has been eradicated with graft implantation if it is needed. Debridement, exchange nailing and systemic administration of antibiotics is the best indication for stage III (late) infections, while stage III infected non-unions can successfully be treated with nail removal and Ilizarov frame, especially when large bone defects exist. PMID:23919097
Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit
2017-07-01
Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.
Biomechanical investigation of a novel ratcheting arthrodesis nail.
McCormick, Jeremy J; Li, Xinning; Weiss, Douglas R; Billiar, Kristen L; Wixted, John J
2010-10-14
Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion.
Biomechanical investigation of a novel ratcheting arthrodesis nail
2010-01-01
Background Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. Methods A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Results Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. Conclusion With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion. PMID:20942976
Mabry, Tad M; Jacofsky, David J; Haidukewych, George J; Hanssen, Arlen D
2007-11-01
We analyzed knee arthrodesis for the infected total knee replacement (TKR) using two different fixation techniques. Patients undergoing knee arthrodesis for infected TKR were identified and rates of successful fusion and recurrence of infection were compared using Cox proportional hazard models. Eighty-five consecutive patients who underwent knee arthrodesis were followed until union, nonunion, amputation, or death. External fixation achieved successful fusion in 41 of 61 patients and was associated with a 4.9% rate of deep infection. Fusion was successful in 23 of 24 patients with intramedullary (IM) nailing and was associated with an 8.3% rate of deep infection. We observed similar fusion and infection rates with the two techniques. Thirty-four patients (40%) had complications. Knee arthrodesis remains a reasonable salvage alternative for the difficult infected TKR. Complication rates are high irrespective of the technique, and one must consider the risks of both nonunion and infection when choosing the fixation method in this setting. IM nailing appears to have a higher rate of successful union but a higher risk of recurrent infection when compared with external fixation knee arthrodesis. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Gadea, F; Favard, L; Boileau, P; Cuny, C; d'Ollone, T; Saragaglia, D; Sirveaux, F
2016-12-01
No objective criteria exist to help surgeons choose between IM nailing and plate fixation for 4-part fractures of the proximal humerus. The goal of this study was to identify radiological criteria that would make one technique a better choice than the other. This was a comparative, multicentre, retrospective study of 54 cases of antegrade nailing and 53 cases of plating performed between 1st January 2009 and 31 December 2011 for 4-part fractures of the proximal humerus. All patients had a minimum radiological and clinical follow-up of 18 months. The functional outcomes were evaluated using the weighted Constant score; a poor result was defined as a weighted Constant score<70%. The following radiological criteria were evaluated during the preoperative assessment and at the last follow-up: initial displacement and reduction of humeral head and tuberosities; morphology of the medial column (i.e. calcar comminution, posteromedial hinge, size of metaphyseal head extension); occurrence of avascular necrosis (AVN). After an average follow-up of 42 months, the weighted Constant scores and rate of poor outcomes were 77% and 48% in the nail group and 81% and 38% in the plate group, respectively (ns). The humeral head was reduced into an anatomical position, valgus or varus in 57%, 30% and 13% of cases in the nail group, and 58%, 29% and 13% in the plate group, respectively. The tuberosities healed in an anatomical position in 72% of nail cases and 70% of plate cases (ns). Only the presence of a medial hinge preoperatively had an effect on the functional outcomes in the nail and plate groups: the weighted Constant scores (P=0.05) and rate of poor outcomes (P=0.02) were 82% and 52% in the nail group and 97% and 9% in the plate group, respectively. The complication rates were comparable: the rates of AVN and articular screw penetration were 17% and 11% in the nail group, and 15% and 11% in the plate group, respectively. The surgical revision rate was 18.5% in the nail group and 30% in the plate group. If the medial hinge is preserved, we recommend locking plate fixation. In other cases, either technique can be used as long as the general rules of internal fixation are applied: reduction of the tuberosities, varus correction and stabilization of the calcar area. IV, retrospective study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F
1992-09-01
The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.
Park, Jong Woong; Kim, Yong-Il; Kang, Hyun Guy; Kim, June Hyuk; Kim, Han Soo
2018-05-15
We introduced a palliative joint-preserving surgery using proximal self-locking screws of intramedullary (IM) nail and percutaneous cementoplasty (PC) in patients with proximal humeral metastases, including the head and neck, and evaluated the outcome of the surgical method. Twenty-three patients (mean age = 63.0 ± 11.8 years, M:F = 14:9) had IM nailing with a self-locking screw system and PC for the treatment of humeral head and neck metastases. Usually, three proximal locking screws were inserted after IM nailing, and 20.9 ± 8.0 ml of polymethylmethacrylate (PMMA) bone cement was injected in the perimetal osteolytic area. Regional anesthesia with interscalene block was performed in 87.0% (20/23), and the duration of surgery (from anesthesia to awakening) was approximately 40-55 min. Red blood cell was not transfused intra- and/or postoperatively in 65.2% (15/23). The localized preoperative pain (visual analog scale (VAS), 8.2 ± 3.1) was gradually decreased at postoperative 1 week (VAS, 4.9 ± 2.1) and at 6 weeks (VAS, 2.9 ± 2.1) (P < 0.001). Among nine patients who underwent F-18-FDG PET/CT, the proximal humeral metastasis around PC showed improved, stable, and aggravated states in five (55.6%), three (33.3%), and one patient (11.1%), respectively. Meanwhile, 88.8% (8/9) of patients showed aggravation at the naive bone metastasis area. The selection of the self-locking screw type of the IM nail and PC was helpful in preventing fixation failure for joint-preserving palliative surgery in the proximal humeral metastasis.
Resection arthrodesis for giant cell tumors around the knee.
Kapoor, Sudhir K; Tiwari, Akshay
2007-04-01
Giant cell tumors (GCTs) of bone are aggressive benign tumors. Wide resection is reserved for a small subset of patients with biologically more aggressive, recurrent and extensive tumors. As the patients affected with GCT are young or middle-aged adults with a normal life expectancy, arthrodesis is an attractive option for reconstruction in these patients. Thirty-six patients of mean age 33.1 years with Campanacci Grade III giant cell tumors around the knee (20 distal femoral and 16 proximal tibial) were treated with wide resection and arthrodesis from January 1996 through January 2006. Arthrodesis was performed using plating with free fibular graft (n = 18), IM nail with free fibular graft (n = 8) and IM nail combined with ring fixator using bone transport (n = 10). Fusion after the first surgery was achieved in 77.7%, 75% and 90% of the patients in the three groups respectively. Local recurrence was seen in two patients and repeat surgery for nonunion/ graft fracture had to be done in four patients and two patients in the plating and nailing groups respectively. Wide resection and arthrodesis in aggressive GCTs around the knee is a good treatment option. IM nail combined with a ring fixator seems to be a good method of arthrodesis with high fusion rates, least shortening and early rehabilitation.
Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas
2008-02-01
Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.
Resection arthrodesis for giant cell tumors around the knee
Kapoor, Sudhir K; Tiwari, Akshay
2007-01-01
Background: Giant cell tumors (GCTs) of bone are aggressive benign tumors. Wide resection is reserved for a small subset of patients with biologically more aggressive, recurrent and extensive tumors. As the patients affected with GCT are young or middle-aged adults with a normal life expectancy, arthrodesis is an attractive option for reconstruction in these patients. Materials and Methods: Thirty-six patients of mean age 33.1 years with Campanacci Grade III giant cell tumors around the knee (20 distal femoral and 16 proximal tibial) were treated with wide resection and arthrodesis from January 1996 through January 2006. Arthrodesis was performed using plating with free fibular graft (n = 18), IM nail with free fibular graft (n = 8) and IM nail combined with ring fixator using bone transport (n = 10). Results: Fusion after the first surgery was achieved in 77.7%, 75% and 90% of the patients in the three groups respectively. Local recurrence was seen in two patients and repeat surgery for nonunion/ graft fracture had to be done in four patients and two patients in the plating and nailing groups respectively. Conclusion: Wide resection and arthrodesis in aggressive GCTs around the knee is a good treatment option. IM nail combined with a ring fixator seems to be a good method of arthrodesis with high fusion rates, least shortening and early rehabilitation. PMID:21139764
Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects
2016-12-01
proximal and distal bone segments. 3. Debride 10 grams of tibialis anterior and gastrocnemius muscles. 4. Place an interlocking intramedullary nail ...using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x 2 cm diameter PMMA spacer around the nail in the defect. 6...tibia. 3. Open the IM surrounding the PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5
Fatigue strength of common tibial intramedullary nail distal locking screws
Griffin, Lanny V; Harris, Robert M; Zubak, Joseph J
2009-01-01
Background Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of withstanding more than a week of weight bearing. If two small diameter screws are used, our tests showed that the probability of withstanding a week of weight bearing increases from zero to about 20 percent, which is similar to having a single 4.5 mm diameter screw providing fixation. Conclusion Our results show that selecting the system that uses the largest distal locking screws would offer the best fatigue resistance for an unstable fracture pattern subjected to full weight bearing. Furthermore, using multiple screws will substantially reduce the risk of premature hardware failure. PMID:19371438
2016-12-01
gastrocnemius muscles. 4. Place an interlocking intramedullary nail using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x...2 cm diameter PMMA spacer around the nail in the defect. 6. Irrigate the wound with normal (0.9 %) saline and close the wound. The Treatment...PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5. Collect appropriate IM samples as
Anderson, Ryan T; Pacaccio, Douglas J; Yakacki, Christopher M; Carpenter, R Dana
2016-09-01
Tibio-talo-calcaneal (TTC) arthrodesis is an end-stage treatment for patients with severe degeneration of the ankle joint. This treatment consists of using an intramedullary nail (IM) to fuse the calcaneus, talus, and tibia bones together into one construct. Poor bone quality within the joint prior to surgery is common and thus the procedure has shown complications due to non-union. However, a new FDA-approved IM nail has been released that houses a nickel titanium (NiTi) rod that uses its inherent pseudoelastic material properties to apply active compression across the fusion site. Finite element analysis was performed to model the mechanical response of the NiTi within the device. A bone model was then developed based on a quantitative computed tomography (QCT) image for anatomical geometry and bone material properties. A total bone and device system was modeled to investigate the effect of bone quality change and gather load-sharing properties during gait loading. It was found that during the highest magnitude loading of gait, the load taken by the bone was more than 50% higher than the load taken by the nail. When comparing the load distribution during gait, results from this study would suggest that the device helps to prevent stress shielding by allowing a more even distribution of load between bone and nail. In conditions where bone quality may vary patient-to-patient, the model indicates that a 10% decrease in overall bone modulus (i.e. material stiffness) due to reduced bone mineral density would result in higher stresses in the nail (3.4%) and a marginal decrease in stress for the bone (0.5%). The finite element model presented in this study can be used as a quantitative tool to further understand the stress environment of both bone and device for a TTC fusion. Furthermore, the methodology presented gives insight on how to computationally program and use the unique material properties of NiTi in an active compression state useful for bone fracture healing or fusion treatments. Copyright © 2016 Elsevier Ltd. All rights reserved.
Minimally invasive plate augmentation in the treatment of long-bone non-unions.
Park, Ki-Chul; Oh, Chang-Wug; Kim, Joon-Woo; Park, Kyeong-Hyeon; Oh, Jong-Keon; Park, Il-Hyung; Kyung, Hee-Soo; Heo, Jeong
2017-11-01
Exchange nailing is most acceptable for treating hypertrophic non-union of the long bones, requiring the removal of previously fixed implant. However, its main effect of mechanical stabilization is controversial in non-isthmal area. We hypothesized that minimally invasive plate augmentation over the non-union site may have a better option, without the need of bone grafting or removing pre-existing implants. Seventeen patients with hypertrophic non-union of the long bones between 2010 and 2014 on radiography who previously underwent intramedullary (IM) nailing or plate osteosynthesis for long-bone fractures were included. A locking compression plate was inserted with at least three mono- or bicortical screws at each proximal and distal segment. Broken or loosened interlocking screws of IM nail were simultaneously re-fixed. Fracture site exposure, pre-fixed implant removal, and bone grafting were not performed. We investigated whether union occurred and analyzed functional outcomes and complications. Eleven femoral and six tibial non-unions were prospectively included. In the pre-existing implants, 13 nails and 4 plates were found. All cases achieved union at a mean 22.7 weeks. One case of superficial infection was managed with oral antibiotics. Deep infection or implant failure did not occur. Minimally invasive plate augmentation can achieve additional stability and promote healing of hypertrophic non-union of the long bones. When indicated, this technique is the least invasive alternative to exchange nailing and reduces surgical risks in the treatment of diaphyseal non-union.
Herrera-Soto, José A; Meuret, Robert; Phillips, Jonathan H; Vogel, Daniel J
2015-01-01
To evaluate locked intramedullary (IM) fixation as an alternative treatment method for children with subtrochanteric fractures. Retrospective review. Level 1 trauma center in a Children's Hospital. Pediatric patients with subtrochanteric femur fractures with open growth plates. All patients were treated with a lateral entry IM locking nail. Patients were followed until full fracture consolidation or until implant removal. Data on time to full weight bearing, return to full activity, residual pain, any form of gait abnormality, and any other complication from follow-up visits were collected. There were 9 males and 1 female patient with an average age of 12 years and average follow-up of 22 months. Most of the fractures occurred secondary to high-energy trauma. Partial weight bearing was started at 24 days and full at 66 days. Implants were removed on average at 11 months after implantation. There were neither intraoperative complications nor major complications in the postoperative period recorded after removal. Two patients presented with a longer limb on the affected side, both 8 mm, and 2 presented with asymptomatic grade I heterotopic ossification. The use of a statically locked lateral entry IM nail for subtrochanteric femur fractures in children is a safe and efficacious method of treatment with few complications and risks and satisfactory outcomes in children over the age of 8 years. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis
2008-10-01
Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.
Russell, Thomas A; Mir, Hassan R; Stoneback, Jason; Cohen, Jose; Downs, Brandon
2008-07-01
To determine our rate of malalignment in proximal femoral shaft fractures treated with intramedullary (IM) nails, with and without the use of a minimally invasive nail insertion technique (MINIT). Retrospective study. Level 1 trauma center. Between July 1, 2003, and June 31, 2005, 100 consecutive proximal femoral shaft fractures (97 patients) were treated with IM nails. The average age of the 56 men and 41 women was 43.5 years (range, 17 to 96 years). There were 92 closed fractures and 8 open fractures. Fractures were classified according to the Russell-Taylor classification (69 type 1A, 11 type 1B, 3 type 2A, 17 type 2B). All patients underwent antegrade IM nailing using a fracture table in the supine (83) or lateral (17) position. A total of 72 entry portals were trochanteric, and 28 were piriformis. Seventy-seven percent of the femurs were opened with MINIT, a technique that uses a percutaneous cannulated channel reamer over a guide pin as opposed to the standard method of Kuntscher, which employs a femoral awl. Nails were locked proximally using standard locking in 37 fractures, and recon mode in 63. Fracture reduction was examined on immediate postoperative films to determine angulation in the coronal and sagittal planes. Criteria for acceptable reduction were less than 5 degrees angulation in any plane. In addition, surgical position, entry portal, mechanism of injury, Russell-Taylor classification, OTA classification, open or closed fracture, open or closed reduction, and type of implant used were analyzed for significance. The frequency of malalignment was 10% for the entire group of patients. Malalignment occurred in 26% of fractures treated without the use of the MINIT and in 5.2% when the MINIT was used (P < 0.01). There was no statistically significant difference between the different Russell-Taylor fracture types, although there was a trend towards more malalignment in type 2A and 2B fractures (P = 0.06). None of the other factors studied had a statistically significant effect on malalignment. A whole-model test of the factors that were surgeon-controlled (use of the MINIT, surgical position, open or closed reduction, type of implant used, and entry portal) found that only use of the MINIT had a statistically significant effect on malalignment (P < 0.01). The results indicate that use of the minimally invasive nail insertion technique (MINIT) significantly decreases the occurrence of malalignment in proximal femoral shaft fractures.
In vivo evaluation of a magnesium-based degradable intramedullary nailing system in a sheep model.
Rössig, Christina; Angrisani, Nina; Helmecke, Patrick; Besdo, Silke; Seitz, Jan-Marten; Welke, Bastian; Fedchenko, Nickolay; Kock, Heiko; Reifenrath, Janin
2015-10-01
The biocompatibility and the degradation behavior of the LAE442 magnesium-based intramedullary interlocked nailing system (IM-NS) was assessed in vivo in a comparative study (stainless austenitic steel 1.4441LA) for the first time. IM-NS was implanted into the right tibia (24-week investigation period; nails/screws diameter: 9 mm/3.5 mm, length: 130 mm/15-40 mm) of 10 adult sheep (LAE442, stainless steel, n=5 each group). Clinical and radiographic examinations, in vivo computed tomography (CT), ex vivo micro-computed tomography (μCT), mechanical and histological examinations and element analyses of alloying elements in inner organs were performed. The mechanical examinations (four-point bending) revealed a significant decrease of LAE442 implant stiffness, force at 0.2% offset yield point and maximum force. Periosteal (new bone formation) and endosteal (bone decline) located bone alterations occurred in both groups (LAE442 alloy more pronounced). Moderate gas formation was observed within the LAE442 alloy group. The CT-measured implant volume decreased slightly (not significant). Histologically a predominantly direct bone-to-implant interface existed within the LAE442 alloy group. Formation of a fibrous tissue capsule around the nail occurred in the steel group. Minor inflammatory infiltration was observed in the LAE442 alloy group. Significantly increased quantities of rare earth elements were detected in the LAE442 alloy group. μCT examination showed the beginning of corrosion in dependence of the surrounding tissue. After 24 weeks the local biocompatibility of LAE442 can be considered as suitable for a degradable implant material. An application oriented interlocked intramedullary nailing system in a comparative study (degradable magnesium-based LAE442 alloy vs. steel alloy) was examined in a sheep model for the first time. We focused in particular on the examination of implant degradation by means of (μ-)CT, mechanical properties (four-point bending), clinical compatibility, local bone reactions (X-ray and histology) and possible systemic toxicity (histology and element analyses of inner organs). A significant decrease of magnesium (LAE442 alloy) implant stiffness and maximum force occurred. Moderate not clinically relevant gas accumulation was determined. A predominantly direct bone-to-implant contact existed within the magnesium (LAE442 alloy) group compared to an indirect contact in the steel group. Rare earth element accumulation could be observed in inner organs but H&E staining was inconspicuous. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Lee, Moses; Choi, Woo Jin; Han, Seung Hwan; Jang, Jinyoung; Lee, Jin Woo
2017-07-22
Tibiotalocalcaneal (TTC) fusion using a retrograde intramedullary (IM) nail is an effective salvage option for terminal-stage hindfoot problems. However, as many patients who receive TTC fusion bear unfavorable medical comorbidities, the risk of nonunion, infection and other complications increases. This study was performed to identify the factors influencing outcomes after TTC fusion using a retrograde IM nail. Between September 2008 and February 2012, 34 consecutive patients received TTC fusion using a retrograde IM nail for limb salvage. All patients had a minimum follow-up of two years. Throughout follow-up, standard ankle radiography was performed along with clinical outcome assessment using a visual analog scale (VAS) for pain, the American Orthopaedic Foot and Ankle Society Ankle-Hind Foot Scale (AOFAS A/H scale) and the Foot and Ankle Outcome Score (FAOS). For the retrospective analysis, demographic factors, preoperative medical status, laboratory markers, and etiology were comprehensively reviewed using medical records. The success of the index operation was determined using clinical and radiological outcomes. Finally, the effect of each factor on failure after the operation was analyzed using univariate logistic regression. In a mean of seven months, 82% (28/34) achieved union, as evaluated by standard radiography. All clinical outcome parameters improved significantly after the operation, including VAS, AOFAS A/H scale, and FAOS (P<0.001). At the last follow-up, five cases of nonunion with less than AOFAS A/H scale of 80 and two cases of below knee amputation due to uncontrolled infection were determined to be failures. None of the factors (etiology, demographics, laboratory markers and medical status) significantly influenced failures. However, uncontrolled DM significantly increased the failure rate with an odds ratio of 10 (P=0.029). TTC fusion with a retrograde intramedullary nail is a successful treatment for complicated hindfoot problems such as traumatic osteoarthritis, Charcot arthropathy and failed TAA. However, it should be used judiciously in patients with uncontrolled DM, as the risk of failure increases. Retrospective cohort study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Bactericidal micron-thin sol-gel films prevent pin tract and periprosthetic infection.
Qu, Haibo; Knabe, Christine; Burke, Megan; Radin, Shula; Garino, Jonathan; Schaer, Thomas; Ducheyne, Paul
2014-08-01
Orthopedic injuries constitute the majority of wounds sustained by U.S. soldiers in recent conflicts. The risk of infection is considerable with fracture fixation devices. In this pilot study, we examined the use of unique bactericidal micron-thin sol-gel films on fracture fixation devices and their ability to prevent and eradicate infections. External fixation was studied with micron-thin sol-gel coated percutaneous pins releasing triclosan and inserted medially into rabbit tibiae. A total of 11 rabbits received percutaneous pins that were either uncoated or sol-gel/triclosan coated. Internal fracture fixation was also studied using sol-gel coated intramedullary (IM) nails releasing vancomycin in the intramedullary tibiae. Six sheep received IM nails that were coated with a sol-gel film that either contained vancomycin or did not contain vancomycin. All animals were challenged with Staphylococcus aureus around the implant. Animals were euthanized at 1 month postoperative. Rabbits receiving triclosan/sol-gel coated percutaneous pins did not show signs of infection. Uncoated percutaneous pins had a significantly higher infection rate. In the sheep study, there were no radiographic signs of osteomyelitis with vancomycin/sol-gel coated IM nails, in contrast to the observations in the control cohort. Hence, the nanostructured sol-gel controlled release technology offers the promise of a reliable and continuous delivery system of bactericidals from orthopedic devices to prevent and treat infection. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Sim, Jae Ang; Lee, Beom Koo; Kwak, Ji Hoon; Moon, Sung Hoon
2009-02-01
We report a case of knee fusion after a failed total knee arthroplasty (TKA) with severe osteolysis including the epicondyle and ipsilateral total hip arthroplasty (THA) with long Wagner revision stem (Sulzer Orthopedics, Baar, Switzerland). The conventional devices for arthrodesis were unavailable in this case because of the long Wagner revision stem and poor bone stock. A connector was made between the long Wagner revision stem and an intramedullary nail (IM nail; Solco, Seoul, Korea). The custom-made connector was coupled with a femoral stem by cylindrical taper fit with additional cement augmentation and an intramedullary nail by screws. Osseous fusion was achieved without pain or instability.
Samiezadeh, Saeid; Fawaz, Zouheir; Bougherara, Habiba
2016-03-01
Intramedullary nails are the golden treatment option for diaphyseal fractures. However, their high stiffness can shield the surrounding bone from the natural physiologic load resulting in subsequent bone loss. Their stiff structure can also delay union by reducing compressive loads at the fracture site, thereby inhibiting secondary bone healing. Composite intramedullary nails have recently been introduced to address these drawbacks. The purpose of this study is to evaluate the mechanical properties of a previously developed composite IM nail made of carbon-fibre/epoxy whose structure was optimized based on fracture healing requirements using the selective stress shielding approach. Following manufacturing, the cross-section of the composite nail was examined under an optical microscope to find the porosity of the structure. Mechanical properties of the proposed composite intramedullary nail were determined using standard tension, compression, bending, and torsion tests. The failed specimens were then examined to obtain the modes of failure. The material showed high strength in tension (403.9±7.8MPa), compression (316.9±10.9MPa), bending (405.3±8.1MPa), and torsion (328.5±7.3MPa). Comparing the flexural modulus (41.1±0.9GPa) with the compressive modulus (10.0±0.2GPa) yielded that the material was significantly more flexible in compression than in bending. This customized flexibility along with the high torsional stiffness of the nail (70.7±2.0Nm(2)) has made it ideal as a fracture fixation device since this unique structure can stabilize the fracture while allowing for compression of fracture ends. Negligible moisture absorption (~0.5%) and low porosity of the laminate structure (< 3%) are other advantages of the proposed structure. The findings suggested that the carbon-fibre/epoxy intramedullary nail is flexible axially while being relatively rigid in bending and torsion and is strong enough in all types of physiologic loading, making it a potential candidate for use as an alternative to the conventional titanium-alloy intramedullary nails. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil
2018-05-01
To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with <1.5 cm LLD, 13/21 had a correction all to ≤0.6 cm, and 8 decided to accept the LLD and declined early correction. No patient left the hospital with an LLD >1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
on fracture healing. Clin Orthop Relat Res. 1998;355(Suppl):S230–8. 37. Pape HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4...BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...2, TPO, or saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone
Shaha, James S; Cage, Jason M; Black, Sheena R; Wimberly, Robert L; Shaha, Steven H; Riccio, Anthony I
The ideal canal fill for flexible intramedullary fixation of pediatric femoral shaft fractures is considered to be 80% based upon relatively few clinical studies. The purpose of this study is to assess the relationship between the summed nail to intramedullary canal diameter (ND/MCD) ratio and alignment at radiographic union following flexible intramedullary nailing (FIMN) of pediatric femoral shaft fractures. An Internal Review Board approved, retrospective review of a consecutive series of patients who sustained a femoral shaft fracture treated by retrograde, stainless steel FIMN was performed at a single level 1 pediatric trauma center from 2005 to 2012. Preoperative radiographs were analyzed to determine fracture pattern, location, and isthmic canal diameter. ND/MCD ratio was calculated using the sum of the known nail diameters and the measured isthmic diameter. Radiographs at bony union were reviewed to measure shortening, coronal angulation, and sagittal angulation. ND/MCD ratio was analyzed to determine correlative factors with final radiographic outcomes. In total, 261 children underwent retrograde FIMN at an average age of 8.2 years (range, 2.2 to 17.0 y). ND/MCD ratio of ≥80% was seen in 108 (41.4%) patients. When compared with those with <80% ND/MCD ratio, there were no significant differences in age (8.8 vs. 8.0 y), sex (76.9% vs. 71.0% males), or body mass index (18.5 vs. 17.2 kg/m). There were significantly more length unstable fractures in the <80% ND/MCD ratio group (49.4% vs. 29.7%; P<0.01). Radiographic outcome was no different with respect to coronal angulation (2.7 vs. 3.0 degrees), sagittal angulation (3.0 vs. 3.2 degrees), or shortening (2.5 vs. 4.1 mm). ND/MCD ratio of ≥70% was seen in 176 (67.4%) patients and, when compared with the <70% ND/MCD ratio group, there were no differences in shortening (3.3 vs. 3.9 mm), coronal angulation (2.8 vs. 3.0 degrees), or sagittal angulation (3.0 vs. 3.4 degrees). Finally, 6.9% of the population (18 patients) had ND/MCD ratios <60% and did not demonstrate a significant increase in shortening, coronal, or sagittal angulation compared with groups with higher ND/MCD ratios. No group had an increased rate of infection, implant removal, nonunion, or need for reoperation. In a large series of consecutive patients treated with retrograde stainless steel FIMN there does not appear to be any correlation between the ND/MCD ratio and radiographic outcome. Stainless steel flexible IM nails seem to maintain fracture alignment without an increase in complications at lower ND/MCD ratios than previously reported as "optimal." Level III.
Novel Therapy for Bone Regeneration in Large Segmental Defects
2016-10-01
Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda K, Ritter G, Degreif J, Rudigier J. Pathogenesis of pul- monary... fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda K, Ritter G, Degreif J, Rudigier J. Pathogenesis of pul...morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17... fracture healing, bone regeneration, minipig, pig 3. OVERALL PROJECT SUMMARY: Project start date 30/09/2013 Project end date 29/09/2017 (with 1 year NCE
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
healing. Clin Orthop Relat Res. 1998;355(Suppl):S230–8. 37. Pape HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda...mechanisms to elicit bone healing. 15. SUBJECT TERMS Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing...thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 3. OVERALL PROJECT SUMMARY: Project start date 30/09/2013 Project end
Vaughn, Josh; Cohen, Eric; Vopat, Bryan G; Kane, Patrick; Abbood, Emily; Born, Christopher
2015-05-01
Hip fractures are becoming increasingly common resulting in significant morbidity, mortality and raising healthcare costs. Both short and long cephalomedullary devices are currently employed to treat intertrochanteric hip fractures. However, which device is optimal continues to be debated as each implant has unique characteristics and theoretical advantages. This study looked to identify rates of complications associated with both long and short cephalomedullary nails for the treatment of intertrochanteric hip fractures. We retrospectively reviewed charts from 2006 to 2011, and we identified 256 patients were identified with AO class 31.1-32.3 fractures. Sixty were treated with short nails and 196 with long nails. Radiographs and charts were then analysed for failures and hardware complications. Catastrophic failure and hardware complication rates were not statistically different between short or long cephalomedullary nails. The overall catastrophic failure rate was 3.1 %; there was a 5 % failure rate in the short-nail group compared with a 2.6 % failure rate in the long-nail group (p = 0.191). There was a 3.33 % secondary femur fracture rate in the short-nail group, compared with none in the long-nail cohort (p = 0.054). The rate of proximal fixation failure was 1.67 % for the short-nail group and 2.0 % in the long-nail group (p = 0.406). Our data suggests equivocal outcomes as measured by similar catastrophic failure rate between both short and long cephalomedullary nails for intertrochanteric femur fractures. However, there was an increased risk of secondary femur fracture with short cephalomedullary nails when compared to long nails that approached statistical significance.
Sano, Hitomi; Shionoya, Kaori; Ogawa, Rei
2014-04-01
We studied the relationship between mechanical force and nail curvature. The effect of different frequencies and strengths of mechanical force on nail curvature was assessed. In Study 1, 63 carpenters and 63 office workers were enrolled, and the configurations of their thumb nails were assessed by measuring the curve index (defined as nail height/width) and pinch strength. In Study 2, nail curvature and pinch strength of jazz bassists, who characteristically do not use the right fourth and fifth fingers but use the left fifth finger a lot, were compared. In Study 3, the thumb nail curvature and pinch strength of the dominant and nondominant sides of the 126 participants from Study 1 were compared. Study 1: Carpenters had a significantly lower mean thumb nail curve index and higher mean pinch strength. Study 2: The nails of the unused right fourth and fifth fingers were much more curved than the nails of the frequently used left fourth and fifth fingers. The pinch strength of the right fifth finger was much weaker than the pinch strength of the left fifth finger. Study 3: The dominant side had a significantly lower nail curve index and higher pinch strength. The frequency and strength of mechanical forces on finger nails significantly affect nail appearance. © 2014 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.
Chen, Daoyun; Chen, Jianmin; Jiang, Yao; Liu, Fanggang
2011-06-01
Leg discrepancy is common after poliomyelitis. Tibial lengthening is an effective way to solve this problem. It is believed lengthening over a tibial intramedullary nail can provide a more comfortable lengthening process than by the conventional technique. However, patients with sequelae of poliomyelitis typically have narrow intramedullary canals allowing limited space for inserting a tibial intramedullary nail and Kirschner wires. To overcome this problem, we tried using humeral nails instead of tibial nails in the lengthening procedure. In this study, we used humeral nails in 20 tibial lengthening procedures and compared the results with another group of patients who were treated with tibial lengthening over tibial intramedullary nails. The mean consolidation index, percentage of increase and external fixation index did not show significant differences between the two groups. However, less blood loss and shorter operating time were noted in the humeral nail group. More patients encountered difficulty with the inserted intramedullary nail in the tibial nail group procedure. The complications did not show a statistically significant difference between the two techniques on follow-up. In conclusion, we found the humeral nail lengthening technique was more suitable in leg discrepancy patients with sequelae of poliomyelitis.
Weninger, Patrick; Schueller, Michael; Jamek, Michael; Stanzl-Tschegg, Stefanie; Redl, Heinz; Tschegg, Elmar K
2009-05-01
Unreamed tibia nails with small diameters are increasingly used for fracture fixation. However, little is known about the fatigue strength of proximal and distal interlocking screws in those nails. To date, no data are available reporting on mechanical differences of solid compared to cannulated tibial nails. The aim of this study was to assess the fatigue strength of proximal and distal interlocking screws of solid and cannulated small diameter tibia nails. We created a distal tibia fracture model (AO/OTA 43 A3) using 16 Sawbones. After fracture stabilization with one of four different nail types (Expert Tibial Nail, VersaNail, T2 Tibial Nailing System, Connex), mechanical testing was performed in three loading series (40,000 cycles each) with incremental loads. Timing and type of interlocking screw failure were assessed. Interlocking screw failure was observed significantly earlier (after a mean interval of 57,042 cycles) in cannulated tibial nails (VersaNail, T2) compared to solid nails (after a mean interval of 88,415 cycles; P < 0.001). Proximal interlocking screw failure was recorded if oblique screws were used proximally (VersaNail, T2, Connex). No distal interlocking screw failure was recorded in the Connex nail. Two- and three-part fractures of proximal or distal interlocking screws were observed in all specimen. Proximal and distal interlocking screw failure has to be considered in small diameter nails in case of delayed fracture healing. To support our results, further experimental studies and clinical series are necessary.
NASA Astrophysics Data System (ADS)
Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng
2017-07-01
The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.
A quantitative method for measuring forces applied by nail braces.
Erdogan, Fatma G
2011-01-01
Nail bracing is a conservative method used for ingrown nails; however, lack of objective measurements limits its use for various nails. Double-string nail braces with extra metal springs were applied to 12 patients with 21 chronic, thick, and overcurved ingrown nails. Force was measured with a force gauge meter. Treatment was stopped once patients stood on their tiptoes and walked in shoes pain free without braces. A force gauge meter was also used on a model nail to show the forces applied by various nail braces and to compare their pulling forces. After 6 to 10 months of treatment, all of the patients were pain free; 600 to 1,000 centi Newtons of force were applied to the nails. As the width of the nail increased, so did the force. Braces exert more force on larger nails, which may shorten treatment durations. By measuring forces, it may be possible to standardize force and duration of treatment according to variables such as nail thickness, nail width, angle of ingrown nail, and duration of symptoms.
Revisiting Pneumatic Nail Gun Trigger Recommendations.
Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley
2015-03-01
Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.
The use of topical minoxidil to accelerate nail growth: a pilot study.
Aiempanakit, Kumpol; Geater, Alan; Limtong, Preeyachat; Nicoletti, Kathleen
2017-07-01
Linear nail growth rate is affected by various conditions, one of which is the level of blood flow. Our supposition was that topical minoxidil, which has vasodilatory properties, can increase the rate of nail growth. The aim of this study was to determine the impact of topical minoxidil on nail growth. A 5% topical minoxidil solution was applied twice daily to the fingernails of 32 participants. Two groups of 16 participants were randomly chosen. In one group, the applications were made to the right index and left ring fingernails, and, in the other, the left index and right ring fingernails. During each visit (weekly during the first month and every 2 weeks during the second month), the nail length of six fingernails (index, middle, and ring of both hands) was measured using a digital caliper. Beginning in the first week, the mean nail length of the treated nails was greater than that of nails in the untreated group with statistical significance. There were no systemic or cutaneous side effects. During the first month, the mean growth of the treated nails was 4.27 mm/month compared with 3.91 mm/month in the untreated nails (P = 0.003). These findings suggest that a 5% concentration of topical minoxidil can stimulate nail growth with increased growth beginning in the first week of application. The results may have important implications for the treatment of nail disorders; however, a comparable study involving participants with nail disorders is highly recommended. © 2017 The International Society of Dermatology.
Revisiting Pneumatic Nail Gun Trigger Recommendations
Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley
2015-01-01
Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020
Prediction of a nail polish colour applied on a nail.
Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M
2018-02-01
The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Pediatric Diaphyseal Femur Fractures: Submuscular Plating Compared With Intramedullary Nailing.
Sutphen, Sean A; Mendoza, Juan D; Mundy, Andrew C; Yang, Jingzhen G; Beebe, Allan C; Samora, Walter P; Klingele, Kevin E
2016-11-01
This study compared the radiographic and clinical outcomes of pediatric diaphyseal femur fractures treated by submuscular plating, flexible retrograde intramedullary nailing, or rigid antegrade intramedullary nailing with a trochanteric entry point in skeletally immature patients who were 8 years and older. A retrospective review was conducted of skeletally immature patients 8 years and older who were treated for femur fracture with submuscular plating, flexible intramedullary nailing, or rigid intramedullary nailing from 2001 to 2014 with a minimum 12-week follow-up. Treatment outcomes were compared for statistical significance, including time to union, malunion, nonunion, heterotopic ossification, avascular necrosis, time to full weight bearing, limb length discrepancy, residual limp, painful hardware, and infection. The study identified 198 femur fractures in 196 patients (mean age, 11.9 years). Each femur fracture was treated with submuscular plating (35), flexible intramedullary nailing (61), or rigid intramedullary nailing (102). Mean follow-up across the cohort was 48 weeks, ranging from 12 to 225 weeks. Flexible nailing was associated with an increased incidence of malunion (P<.0001) and hardware irritation (P=.0204) and longer time to full weight bearing (P=.0018). Rigid nailing was associated with an increased incidence of limp at 12-week followup (P=.0412). Additionally, 23.5% of patients who were treated with rigid nailing had heterotopic ossification. Of all surgical methods, submuscular plating allowed for the most rapid return to full weight bearing (mean, 7 weeks) and offered the fastest healing rate (mean, 6 weeks). Submuscular plating resulted in faster times to union and full weight bearing, with minimal complication rates. Rigid intramedullary nailing with trochanteric entry resulted in a lower incidence of malunion and hardware-related complications; however, these patients had an increased incidence of heterotopic ossification and residual limp postoperatively. Flexible retrograde intramedullary nailing resulted in the highest rates of malunion and hardware irritation and the longest time to full weight bearing. [Orthopedics. 2016; 39(6):353-358.]. Copyright 2016, SLACK Incorporated.
Withdrawal Strength and Bending Yield Strength of Stainless Steel Nails
Douglas R. Rammer; Samuel L. Zelinka
2015-01-01
It has been well established that stainless steel nails have superior corrosion performance compared to carbon steel or galvanized nails in treated wood; however, their mechanical fastening behavior is unknown. In this paper, the performance of stainless steel nails is examined with respect to two important properties used in wood connection design: withdrawal strength...
Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.
Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L
2016-10-01
For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin
2013-12-01
This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were collected with a demographic form, a nail-biting follow-up form, and photographs of the fingernails. It was found that 68.9% of students were biting seven or more of their nails; 46.6% had damaged nail beds. In the intervention group, the rate of the children who were not biting their nails (baseline = 0%, 4th week = 56.0%, 8th week = 64.0%) increased significantly compared to the control group (baseline = 0%, 4th week = 15.1%, 8th week = 18.9%). Outcomes indicate the efficacy of the healthy nails program in reducing the nail-biting problem in schoolchildren.
Shin, Won Chul; Moon, Nam Hoon; Jang, Jae Hoon; Lee, Hee Jin; Suh, Kuen Tak
2017-10-01
The objective of this study is to evaluate the outcome measures of subtrochanteric fractures between biologic plating and intramedullary nailing and determine if biologic plating is superior to intramedullary nailing. Between March 2009 and December 2015, 81 patients with subtrochanteric fractures were enrolled (52 males and 29 females; 31 treated with biologic plating and 50 with intramedullary nailing). Biologic plating was conducted consecutively between May 2011 and March 2013 and intramedullary nailing was performed for the rest of period. Perioperative outcomes including operation time and blood loss during the operation; postoperative radiologic outcomes including union, time to union, coronal alignment, and shortening of the femur; and clinical outcomes including walking ability and pain were evaluated. The biologic plating group was compared with the intramedullary nailing group as a historical control. No significant differences were identified for bony union and time to union between the two different fixation methods Coronal alignment was significantly better in the biologic plating group than in the intramedullary nailing group (p<0.016). Postoperative coronal alignment was the only risk factor associated with the nonunion of subtrochanteric fractures (unadjusted OR: 1.915, 95% CI: 0.190 - 19.273; adjusted OR: 0.042, 95% CI: 0.000 - 21.517; p=0.320). Surgical outcomes using LCP-DF are comparable to those using intramedullary nailing. Further clinical studies with a larger sample size are required to show the advantage of biologic plating for the treatment of subtrochanteric fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina
2017-01-01
Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921
Gyaneshwar, Tank; Nitesh, Rustagi; Sagar, Tomar; Pranav, Kothiyal; Rustagi, Nitesh
2016-08-01
Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures. The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria. Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed in titanium group but five in stainless steel group. Majority of paediatric femoral shaft fractures are now treated operatively by elastic stable intramedullary nails. Operative intervention results in a shorter hospital stay and has economic and social benefits over conservative treatment. The cost of stainless steel nail is one third the cost of titanium nail. However, the clinico-radiological results are not significantly different between titanium and stainless steel nails at one year follow-up as observed by our study.
Knee arthrodesis using a short locked intramedullary nail. A new technique.
Cheng, S L; Gross, A E
1995-01-01
This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.
Ghanizadeh, Ahmad; Bazrafshan, Amir; Dehbozorgi, Gholamreza
2013-01-01
Objective This is a parallel, three group, randomized, controlled clinical trial, with outcomes evaluated up to three months after randomization for children and adolescents with chronic nail biting. The current study investigates the efficacy of habit reversal training (HRT) and compares its effect with object manipulation training (OMT) considering the limitations of the current literature. Method Ninety one children and adolescents with nail biting were randomly allocated to one of the three groups. The three groups were HRT (n = 30), OMT (n = 30), and wait-list or control group (n = 31). The mean length of nail was considered as the main outcome. Results The mean length of the nails after one month in HRT and OMT groups increased compared to the waiting list group (P < 0.001, P < 0.001, respectively). In long term, both OMT and HRT increased the mean length of nails (P < 0.01), but HRT was more effective than OMT (P < 0.021). The parent-reported frequency of nail biting did show similar results as to the mean length of nails assessment in long term. The number of children who completely stopped nail biting in HRT and OMT groups during three months was 8 and 7, respectively. This number was zero during one month for the wait-list group. Conclusion This trial showed that HRT is more effective than wait-list and OMT in increasing the mean length of nails of children and adolescents in long terms. PMID:24130603
Veen, Egbert J D; Ettema, Harmen B; Zuurmond, Rutger G; Mostert, Adriaan K
2011-10-01
The distal locking of an intramedullary tibial nail can be challenging and time consuming when performed freehand. This study was conducted to evaluate if a distal aiming device would reduce surgical time. A case-controlled study was performed between 2007 and 2009 with 30 patients receiving a reamed tibial nail (Centronail) with the use of a distal aiming device and 30 patients who were treated with an Unreamed Tibia Nail (UTN), with freehand distal locking, in the same period. The primary outcome in this study was operative time. Secondary outcomes were the need for fluoroscopy, time to consolidation and complications. Operation time was longer in the Centronail group compared with the UTN group (126 min vs. 96 min, p=0.000). Use of fluoroscopy for distal locking was needed in half of the cases (n=16) using a distal aiming device. No differences were found regarding time to consolidation, time to removal of the nail and complications. The use of an aiming device for distal locking of a tibia nail lengthens operation time rather than reducing it. Fluoroscopy was still needed in about half of the cases. No difference was seen in clinical outcomes. The use of a distal aiming device to lock a tibial nail appears to have no benefit. Copyright © 2011 Elsevier Ltd. All rights reserved.
Evaluating a county-based Healthy nail Salon Recognition Program
To determine whether nail solons that participate in the SF recognition program have reduced measured levels of toluene, methyl methacrylate (MMA), and total volatile organic compounds (TVOC)as compared to nail salons that do not participate. We also evaluated changes in worker ...
Zehir, Sinan; Çalbıyık, Murat; Şahin, Ercan; İpek, Deniz
2016-01-01
The aim of this study was to compare the results of expandable flexible locked intramedullary nailing and anatomical locking plating in clavicular midshaft fractures. Thirty-three patients (21 male, 12 female) who had displaced fractures and at least 2-cm shortening fixed with expandable flexible locked intramedullary nailing and 38 patients (24 male, 14 female) who underwent anatomical locking plating were recruited. Duration of surgery, incision size, duration of hospital stay, union time, and early and late complications were compared between the groups. Functional results were compared with Constant scoring system. Mean duration of surgery was 32.4±9.1 minutes (range: 20-42 minutes) in the nailing group and 54.1±11.9 minutes (range: 42-70 minutes) in the plating group. The incision was 4.1±0.9 cm (range: 3-5 cm) in the nailing group and 9.5±1.7 cm (range: 7-12 cm) in the plating group. Mean union time was 14.8 weeks (range: 10-24 weeks) in the nailing group and 21.3 weeks (range: 12-33 weeks) in the plating group. Mean duration of hospital stay was 3.6±1.1 days (range: 2-4 days) in the plating group, whereas it was 2.3±0.8 days (range: 1-3 days) in the nailing group. In the plating group, an average of 2.7-mm (range: 0-7 mm) shortening was determined in the clavicles that underwent surgery as compared to the intact clavicles, whereas shortening was 2.3 mm (range: 0-6 mm) in the nailing group. Expandable flexible locked intramedullary nailing can provide more successful outcomes than plating in displaced clavicular midshaft fractures, due to advantages such as shorter union time, lower complication rate, and better cosmetic outcomes.
Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures.
Högel, F; Gerlach, U V; Südkamp, N P; Müller, C A
2010-12-01
To determine whether reamed or unreamed intramedullary nailing of femoral fractures results in higher incidence of pulmonary fat embolism, three different methods of intramedullary nailing were compared in sheep. To analyze the presence of bone marrow fat embolism in pulmonary arteries, histological evaluation was undertaken using a quantitative computer-assisted measurement system. In this experimental model of 27 female Swiss alpine sheep, an osteotomy of the proximal femur was conducted in each animal. Then, the animals were divided into three groups according to the method of treatment: two different reamed intramedullary nailing techniques and an unreamed nailing technique were used. In the first group "ER" (experimental reamer; n=9), the nail was inserted after reaming with an experimental reamer; in the second group "CR" (conventional reamer; n=7), the intramedullary nail was inserted after reaming with the conventional AO-reamer. In the third group "UN" (unreamed; n=8) unreamed nailing was performed. During the operation procedure intramedullary pressure was measured in the distal fragment. After sacrificing the animals, quantitative histological analyses of bone marrow fat embolism in pulmonary arteries were done using osmium tetroxide fixation and staining of the fat. The measurement of intramedullary pressure showed significantly lower values for reamed nailing than for the unreamed technique. The quantitative histological evaluation of lung vessels concerning bone marrow fat embolism revealed a statistically significant difference between reamed and unreamed insertion of the nail: 7.77%±6.93 (ER) and 6.66%±5.61 (CR) vs. 16.25%±10.05 (UN) (p<0.05) of the assessed lung vessels were filled with fat emboli. However, no difference was found between the traditional and experimental reamer. Intramedullary nailing after reaming is a safe procedure with low systemic embolisation when compared to the unreamed insertion of the nail. Copyright © 2010 Elsevier Ltd. All rights reserved.
Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J
2017-05-18
To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient's autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.
Grimwood, Darren; Harvey-Lloyd, Jane
2016-12-01
Intramedullary nailing is the standard surgical treatment for mid-diaphyseal fractures of long bones; however, it is also a high radiation dose procedure. Distal locking is regularly cited as a demanding element of the procedure, and there remains a reliance on X-ray fluoroscopy to locate the distal holes. A recently developed electromagnetic navigation (EMN) system allows radiation-free distal locking, with a virtual on-screen image. To compare operative duration, fluoroscopy time and radiation dose when using EMN over fluoroscopy, for the distal locking of intramedullary nails. Consecutive patients with mid-diaphyseal fractures of the tibia and femur, treatable with intramedullary nails, were prospectively enrolled during a 9-month period. The sample consisted of 29 individuals, 19 under fluoroscopic guidance and 10 utilising EMN. Participants were allocated depending on the type of intramedullary nail used and surgeon's preference. These were further divided into tibial and femoral subcategories, relative to the fracture site. EMN reduced fluoroscopy time by 49 (p = 0.038) and 28 s during tibial and femoral nailings, respectively. Radiation dose was reduced by 18 cGy/cm 2 (p = 0.046) during tibial and 181 cGy/cm 2 during femoral nailings when utilising EMN. Operative duration was 11 min slower during tibial nailings using EMN, but 38 min faster in respect of femoral nailings. This study has evidenced statistically significant reductions in both fluoroscopy time and radiation dose when using EMN for the distal locking of intramedullary nails. It is expected that overall operative duration would also decrease in line with similar studies, with increased usage and a larger sample.
Ciclopirox delivery into the human nail plate using novel lipid diffusion enhancers.
Hafeez, Farhaan; Hui, Xiaoying; Selner, Marc; Rosenthal, Bert; Maibach, Howard
2014-06-01
Onychomycosis is a common fungal infection of the nail plate and bed that affects up to 14% of the population and can have a substantial impact on the quality of life of those affected. This study compared the onychopharmacokinetics, nail absorption, nail distribution, and nail penetration of [(14)C]-ciclopirox dissolved in novel lipid diffusion enhancers with that of a commercial ciclopirox nail lacquer using the in vitro finite dose model. The penetration rate of ciclopirox was determined by applying doses of topical formulation twice daily to human nail plates for 11 d. Drug absorption was then measured by monitoring its rate of appearance in each nail layer and in the cotton pad/nail supporting bed. After a multiple day treatment, cumulative concentrations of ciclopirox formulated with lipid enhancers in the deep nail layer and the nail bed were significantly greater than cumulative concentrations of the commercial ciclopirox lacquer (p < 0.001) as well as several orders of magnitude greater than the minimal inhibitory concentration (MIC) deemed necessary to inhibit the growth of the causative dermatophyte species. When formulated with lipid enhancers, the amount of ciclopirox in the ventral/intermediate layer and supporting bed dramatically exceed the inhibitory concentration of ciclopirox for the most common onychomycosis organisms. These results suggest that topical ciclopirox with lipid enhancers has the potential to be an effective topical treatment for onychomycosis, and the lipidic pathway of the nail can be utilized as a means of effective transungual delivery.
Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang
2015-01-01
To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail fixation has a good clinical effect in treating intertrochanteric femur fractures in the elderly. They showed no significant difference in terms of therapeutic effect, hospital stay and postoperative complications. The incidence of periprosthetic fractures treated by either length of nails was low. But short intramedullary nailing can obviously decrease the intraoperative blood loss, operation time and postoperative blood transfusion.
Lin, Yin-Ku; See, Lai-Chu; Huang, Yu-Huei; Chang, Ya-Ching; Tsou, Teng-Cheng; Lin, Tung-Yi; Lin, Na-Ling
2014-06-15
Treating nail psoriasis is notoriously difficult and lacks standardized therapeutic regimens. Indigo naturalis has been demonstrated to be safe and effective in treating skin psoriasis. This trial was conducted to evaluate the efficacy and safety of refined indigo naturalis extract in oil (Lindioil) in treating nail psoriasis. Thirty-one outpatients with symmetrically comparable psoriatic nails were enrolled. Lindioil (experimental group) or olive oil (control group) was applied topically to the same subjects' two bilaterally symmetrical psoriatic nails twice daily for the first 12 weeks and then subjects applied Lindioil to both hands for 12 additional weeks. Outcomes were measured using Nail Psoriasis Severity Index (NAPSI) for five nails on one hand and for the single most severely affected nail from either hand. The results show a reduction of NAPSI scores for the 12-week treatment for the Lindioil group (49.8% for one hand and 59.3% for single nail) was superior to the reduction in the scores for the control group (22.9%, 16.3%, respectively). There were no adverse events during the 24 weeks of treatment. This trial demonstrates that Lindioil is a novel, safe and effective therapy for treating nail psoriasis. Copyright © 2014 Elsevier GmbH. All rights reserved.
Size and Charge Dependence of Ion Transport in Human Nail Plate
Baswan, Sudhir M.; Li, S. Kevin; LaCount, Terri D.; Kasting, Gerald B.
2016-01-01
The electrical properties of human nail plate are poorly characterized, yet are a key determinate of the potential to treat nail diseases such as onychomycosis using iontophoresis. In order to address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of −1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were three-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upwards of 5 Å (approximately MW ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. PMID:26886342
Madry, Milena M; Steuer, Andrea E; Hysek, Cédric M; Liechti, Matthias E; Baumgartner, Markus R; Kraemer, Thomas
2016-01-01
Incorporation rates of the enantiomers of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolite 3,4-methylenedioxyamphetamine (MDA) into hair and nails were investigated after controlled administration. Fifteen subjects without MDMA use received two doses of 125 mg of MDMA. Hair, nail scrapings, and nail clippings were collected 9-77 days after the last administration (median 20 days). Hair samples were analyzed in segments of 1- to 2-cm length. After chiral derivatization with N-(2,4-dinitro-5-fluorophenyl)-L-valinamide, MDMA and MDA diastereomers were analyzed by liquid chromatography-tandem mass spectrometry. Highest concentrations in hair segments corresponded to the time of MDMA intake. They ranged from 101 to 3200 pg/mg and 71 to 860 pg/mg for R- and S-MDMA, and from 3.2 to 116 pg/mg and 4.4 to 108 pg/mg for R- and S-MDA, respectively. MDMA and MDA concentrations in nail scrapings and clippings were significantly lower than in hair samples. There was no significant difference between enantiomeric ratios of R/S-MDMA and R/S-MDA in hair and nail samples (medians 2.2-2.4 for MDMA and 0.85-0.95 for MDA). Metabolite ratios of MDA to MDMA were in the same range in hair and nail samples (medians 0.044-0.055). Our study demonstrates that administration of two representative doses of MDMA was detected in the hair segments corresponding to the time of intake based on average hair growth rates. MDMA was detected in all nail samples regardless of time passed after intake. Comparable R/S ratios in hair and nail samples may indicate that incorporation mechanisms into both matrices are comparable.
Arthrodesis of the knee: experience with intramedullary nailing.
Incavo, S J; Lilly, J W; Bartlett, C S; Churchill, D L
2000-10-01
Knee arthrodesis using an intramedullary nail has gained acceptance as treatment in difficult cases such as infection after total knee arthroplasty (TKA), neuropathic joint, and obesity. A retrospective review of 22 cases treated at our institution using an intramedullary nail for knee arthrodesis was performed. Deep infection after primary (11) or revision (6) TKA was the most common indication for this procedure. A long intramedullary nail was used in 3 cases, a long nail with a proximal interlocking screw was used in 6 cases, and a customized nail with a valgus bend and a proximal interlocking screw was used in 11 cases. A modular knee fusion nail was used in 1 case. Successful fusion occurred in all cases, although 4 patients required additional surgery. Average operative blood loss was 748 mL, and average time to union was 7 months. Shortening of the extremity averaged 3.2 cm. Tibiofemoral alignment was improved by using a customized valgus nail (average, 3.1 valgus; range, 1-5) when compared with a straight nail (average, 0.2 valgus; range, 3 varus to 3 valgus). No patient developed infection in the hip or ankle region as a result of the long intramedullary nail. Intramedullary nailing is an excellent technique for knee arthrodesis in difficult cases. A customized proximal interlocking nail with 5 degrees to 7 degrees of valgus and 5 degrees of anterior angulation improves tibiofemoral alignment and is straightforward to insert or extract should it be necessary. Stability and pain relief are rapid, and the fusion rate is maximized.
Comparative study of nail sampling techniques in onychomycosis.
Shemer, Avner; Davidovici, Batya; Grunwald, Marcelo H; Trau, Henri; Amichai, Boaz
2009-07-01
Onychomycosis is a common problem. Obtaining accurate laboratory test results before treatment is important in clinical practice. The purpose of this study was to compare results of curettage and drilling techniques of nail sampling in the diagnosis of onychomycosis, and to establish the best technique and location of sampling. We evaluated 60 patients suffering from distal and lateral subungual onychomycosis and lateral subungual onychomycosis using curettage and vertical and horizontal drilling sampling techniques from three different sites of the infected nail. KOH examination and fungal culture were used for detection and identification of fungal infection. At each sample site, the horizontal drilling technique has a better culture sensitivity than curettage. Trichophyton rubrum was by far the most common pathogen detected by both techniques from all sampling sites. The drilling technique was found to be statistically better than curettage at each site of sampling, furthermore vertical drilling from the proximal part of the affected nail was found to be the best procedure for nail sampling. With each technique we found that the culture sensitivity improved as the location of the sample was more proximal. More types of pathogens were detected in samples taken by both methods from proximal parts of the affected nails.
Vejnovic, Ivana; Huonder, Cornelia; Betz, Gabriele
2010-09-15
Existing treatments of onychomycosis are not satisfactory. Oral therapies have many side effects and topical formulations are not able to penetrate into the human nail plate and deliver therapeutical concentrations of active agent in situ. The purpose of the present study was to determine the amount of terbinafine, which permeates through the human nail plate, from liquid formulations containing enhancers, namely hydrophobins A-C in the concentration of 0.1% (w/v). The used reference solution contained 10% (w/v) of terbinafine in 60% (v/v) ethanol/water without enhancer. Permeability studies have been performed on cadaver nails using Franz diffusion cells modified to mount nail plates and filled with 60% (v/v) ethanol/water in the acceptor chamber. Terbinafine was quantitatively determined by HPLC. The amount of terbinafine remaining in the nail was extracted by 96% ethanol from pulverized nail material after permeation experiment and presented as percentage of the dry nail weight before the milling test. Permeability coefficient (PC) of terbinafine from reference solution was determined to be 1.52E-10 cm/s. Addition of hydrophobins improved PC in the range of 3E-10 to 2E-9 cm/s. Remaining terbinafine reservoir in the nail from reference solution was 0.83% (n=2). An increase of remaining terbinafine reservoir in the nail was observed in two out of three tested formulations containing hydrophobins compared to the reference. In all cases, known minimum inhibitory concentration of terbinafine for dermatophytes (0.003 microg/ml) has been exceeded in the acceptor chamber of the diffusion cells. All tested proteins (hydrophobins) facilitated terbinafine permeation after 10 days of permeation experiment, however one of them achieved an outstanding enhancement factor of 13.05 compared to the reference. Therefore, hydrophobins can be included in the list of potential enhancers for treatment of onychomycosis. Copyright 2010 Elsevier B.V. All rights reserved.
Size and Charge Dependence of Ion Transport in Human Nail Plate.
Baswan, Sudhir M; Li, S Kevin; LaCount, Terri D; Kasting, Gerald B
2016-03-01
The electrical properties of human nail plate are poorly characterized yet are a key determinate of the potential to treat nail diseases, such as onychomycosis, using iontophoresis. To address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of -1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were 3-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upward of 5 Å (molecular weight, ca. ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Indemini, E; Clerico, P; Fenoglio, E; Mariotti, U
1982-09-01
Endomedullary nailing as proposed by Ender is an important alternative in the treatment of trochanteric and basicervical fractures of the femur (Amici et al., 1980; Carret et al., 1980; Ender, 1970; Kempf et al., 1979; Zinghi et al., 1979). Rush's concept (Eiffel Tower, for the distal epiphysis) is reproposed with some variations and transposed to the femoral neck. The aim of the operation differs from that of the nail and plate technique in that, instead of trying to achieve anatomical reconstruction, an immediate functional by-pass of the fractured part is attempted. After using this technique for three years, we compared the old method, which we had not abandoned, the McLaughlin nail and plate, with the new Ender nail.
Heffernan, Michael J; Gordon, J Eric; Sabatini, Coleen S; Keeler, Kathryn A; Lehmann, Charles L; O'Donnell, June C; Seehausen, Derek A; Luhmann, Scott J; Arkader, Alexandre
2015-03-01
Spica casting is the standard of care for femur fractures in children up to 6 years of age. The indications for surgery are controversial. We sought to compare immediate spica casting (Spica) and flexible intramedullary nailing [titanium elastic nailing (TEN)] in a group of children ages 2 to 6 years. We hypothesized that young children can be successfully treated with flexible nails, resulting in faster return to ambulation and an equivalent complication rate when compared with spica casting. This was a multicenter retrospective review of 215 patients, 141 treated with immediate spica casting, and 74 treated with elastic nails. Patient demographics, fracture characteristics, mechanism of injury, associated injuries, outcomes, and complications were recorded and compared between the 2 groups. Patients in the elastic nailing group were more likely to be injured as a pedestrian struck by an automobile (Spica 8% vs. TEN 26%, P=0.001), and had increased rates of associated injuries (P<0.001). Time to fracture union was similar between the 2 groups (P=0.652). The TEN group had shorter time to independent ambulation (Spica 51±14 vs. TEN 29±14 d, P<0.001) and return to full activities (Spica 87±19 vs. TEN 74±28 d, P=0.023). TEN is a reasonable option for treatment of femur fractures in young children when compared with spica casting with shorter time to independent ambulation and full activities. Fractures associated with a high-energy mechanism are especially appropriate for consideration of treatment with TEN. Level III, this was a retrospective comparative study.
Tibiotalocalcaneal Arthrodesis Nails: A Comparison of Nails With and Without Internal Compression.
Taylor, James; Lucas, Douglas E; Riley, Aimee; Simpson, G Alex; Philbin, Terrence M
2016-03-01
Hindfoot arthrodesis with tibiotalocalcaneal (TTC) intramedullary nails is used commonly when treating ankle and subtalar arthritis and other hindfoot pathology. Adequate compression is paramount to avoid nonunion and fatigue fracture of the hardware. Arthrodesis systems with internal compression have demonstrated superior compression to systems relying on external methods. This study examined the speed of union with TTC fusion nails with internal compression over nails without internal compression. A retrospective review was performed identifying nail type and time to union of the subtalar joint (STJ) and tibiotalar joint (TTJ). A total of 198 patients were included from 2003 to 2011. The median time to STJ fusion without internal compression was 104 days compared to 92 days with internal compression (P = .044). The median time to TTJ fusion without internal compression was 111 days compared to 93 days with internal compression (P = .010). Adjusting for diabetes, there was no significant difference in fusion speed with or without internal compression for the STJ (P = .561) or TTJ (P = .358). Nonunion rates were 24.5% for the STJ and 17.0% for the TTJ with internal compression, and 43.4% for the STJ and 42.1% for the TTJ without internal compression. This difference remained statistically significant after adjusting for diabetes for the TTJ (P = .001) but not for the STJ (P = .194). The intramedullary hindfoot arthrodesis nail was a viable treatment option in degenerative joint disease of the TTC joint. There appeared to be an advantage using systems with internal compression; however, there was no statistically significant difference after controlling for diabetes. Level III, retrospective comparative series. © The Author(s) 2015.
Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Han; Chang, Chih-Wei; Ho, Yi-Hung; Li, Chun-Ting; Peng, Yao-Te
2016-10-01
Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the management of diaphyseal long-bone fractures in adolescents and children, but few studies have investigated the mechanical stability of tibial diaphyseal fractures treated with various degrees of prebending of the elastic nails. Therefore, the aim of this study was to compare the mechanical stability, including the gap deformation and nail dropping, of a tibia fracture with various fracture sites and fixed with various degrees of prebending of the elastic nails by the finite element method. Furthermore, the contribution of end caps to stability was taken into consideration in the simulation. A tibia model was developed with a transverse fracture at the proximal, middle and distal parts of the diaphysis, and fixed with three degrees of prebending of elastic nails, including those equal to, two times and three times the diameter of the intramedullary canal. The outer diameter of the nail used in the computation was 3.5mm, and the fractured tibia was fixed with two elastic double C-type nails. Furthermore, the proximal end of each nail was set to free or being tied to the surrounding bone by a constraint equation to simulate with or without using end caps. The results indicated that using end caps can prevent the fracture gap from collapsing by stopping the ends of the nails from dropping back in all prebending conditions and fracture patterns, and increasing the prebending of the nails to a degree three times the diameter of the canal reduced the gap shortening and the dropping distance of the nail end in those without using end caps under axial compression and bending. Insufficient prebending of the nails and not using end caps caused the gap to collapse and the nail to drop back at the entry point under loading. Using end caps or increasing the prebending of the nails to three times the diameter of the canal is suggested to stop the nail from dropping back and thus produce a more stable structure, with less gap deformation, in the management of a simulated tibial diapyhseal fracture by using titanium elastic nails with a double C-shape. Copyright © 2016 Elsevier Ltd. All rights reserved.
Seo, Jae-Seong; Min, Hak-Jin; Kim, Dong Min; Oh, Seung-Min
2016-01-01
Purpose Cephalomedullary nail (CM nail) in the treatment of femoral intertrochanteric fractures is in the lime light in recent years. The purpose of this study is to compare surgical outcomes between experienced surgeon and non-experienced surgeons in respect of CM nail for femoral intertrochanteric fractures. Materials and Methods The 129 patients underwent CM nail for femoral intertrochanteric fracture more than six months of follow-up from April 2011 to March 2014 in Seoul Medical Center (Seoul, Korea) were participated in this study. For this study, group A consisted of experienced surgeons who performed more than 500 times of CM nail, and group B consisted of non-experienced surgeons who performed less than 50 times of CM nail. Clinical and radiologic outcomes, complications and the need for reoperation between both groups were compared in the study. Results According to clinical result, both the mean operation time and transfusion volume were significantly longer and greater in group B (P<0.05). In the radiologic outcomes, adequacy of reduction, tip-apex distance and numbers of case placed in the Cleveland zones 5, 6 and 8; there was no statistical difference between both groups. Moreover, rate of complication and reoperation had same results as radiologic outcomes. Conclusion There was no significant difference with statistical data in complications from CM nail for femoral intertrochanteric fractures between experienced surgeon and non-experienced surgeon. Although the operation time and transfusion volume were significantly longer and greater in the case of operation by non-experienced surgeon, satisfactory performance was seen in the complications and the need for reoperation. PMID:28097112
Zhang, Sheng; Zhang, Kairui; Wang, Yimin; Feng, Wei; Wang, Bowei; Yu, Bin
2013-01-01
The aim of this study was to use three-dimensional (3D) computational modeling to compare the geometric fitness of these two kinds of proximal femoral intramedullary nails in the Chinese femurs. Computed tomography (CT) scans of a total of 120 normal adult Chinese cadaveric femurs were collected for analysis. With the three-dimensional (3D) computational technology, the anatomical fitness between the nail and bone was quantified according to the impingement incidence, maximum thicknesses and lengths by which the nail was protruding into the cortex in the virtual bone model, respectively, at the proximal, middle, and distal portions of the implant in the femur. The results showed that PFNA-II may fit better for the Chinese proximal femurs than InterTan, and the distal portion of InterTan may perform better than that of PFNA-II; the anatomic fitness of both nails for Chinese patients may not be very satisfactory. As a result, both implants need further modifications to meet the needs of the Chinese population.
A clinical trial to investigate the effect of Cynatine HNS on hair and nail parameters.
Beer, Christina; Wood, Simon; Veghte, Robert H
2014-01-01
A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22.
A Clinical Trial to Investigate the Effect of Cynatine HNS on Hair and Nail Parameters
Veghte, Robert H.
2014-01-01
Objective. A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. Methods. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. Results. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Conclusion. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22. PMID:25386609
Kim, Maru; Song, In-Guk; Kim, Hyung Jin
2015-06-01
The aim of this study was to compare the result of electrocauterization and curettage, which can be done with basic instruments. Patients with ingrown nail were randomized to 2 groups. In the first group, nail matrix was removed by curettage, and the second group, nail matrix was removed by electrocautery. A total of 61 patients were enrolled; 32 patients were operated by curettage, and 29 patients were operated by electrocautery. Wound infections, as early complication, were found in 15.6% (5/32) of the curettage group, 10.3% (3/29) of the electrocautery group patients each (P = .710). Nonrecurrence was observed in 93.8% (30/32) and 86.2% (25/29) of the curettage and electrocautery groups, respectively, (lower limit of 1-sided 90% confidence interval = -2.3% > -15% [noninferiority margin]). To remove nail matrix, the curettage is effective as well as the electrocauterization. Further study is required to determine the differences between the procedures. © The Author(s) 2014.
Brown Nail-bed Arcs and Chronic Renal Disease
Stewart, W. K.; Raffle, E. J.
1972-01-01
A brown arc affecting the distal part of the fingernail-bed, just proximal to the point of separation of the nail from its bed, has been found in 12 out of 34 patients with chronic renal disease (35%) compared with an incidence of less than 2% in a series of unselected patients. It represents a distinctive form of pigmentation, possibly due to lipochromes. No decisive association could be found between the presence or absence of the pigmented nail arc and the level of impaired renal function. Nevertheless it seems that renal disease predisposes towards the development of brown nail arcs. Imagesp786-a PMID:5014252
Evers, Julia; Lakemeier, Martin; Wähnert, Dirk; Schulze, Martin; Richter, Martinus; Raschke, Michael J; Ochman, Sabine
2017-05-01
Although retrograde intramedullary nails for tibiotalocalcaneal arthrodesis (TTCA) are an established fixation method, few studies have evaluated the stability of the available nail systems. The purpose of this study was to compare biomechanically the primary stability of 2 nail-systems, A3 (Small Bone Innovations) and HAN (Synthes), in human cadavers and analyze the exact point of instability in TTCA by means of optical measurement. In 6 pairs of lower legs (n = 12) of fresh-frozen human cadavers with osteoporotic bone structure, bone mineral density (BMD) was determined. Pairwise randomized implantation of either an HAN or A3 nail was executed. Performance and stability were measured by quasi-static tests using 3D motion tracking (NDI Optotrak-Certus) followed by cyclic loading tests during dorsi- and plantarflexion. 3D optical analysis in quasi-static tests showed a significantly lower degree of movement for the HAN nail in rotational and dorsi-/plantarflexion, especially in the subtalar joint. Cyclic loading tests were consistent with quasi-static tests. The A3 nail offered lower stability during axial torsion in the ankle and subtalar joints and during plantar- and dorsiflexion in the subtalar joint in osteoporotic bones. This study was the first to examine the primary stability of different arthrodesis nails in TTCA and their bony parts with a 3D motion analysis. The better stability of the locking-only HAN nail in this osteoporotic test setup could lead to more favorable results in comparison to the A3 nail in clinical use.
Modelling the strength of an aluminium-steel nailed joint
NASA Astrophysics Data System (ADS)
Goldspiegel, Fabien; Mocellin, Katia; Michel, Philippe
2018-05-01
For multi-material applications in automotive industry, a cast aluminium (upper layer) and dual-phase steel (lower layer) superposition joined with High-Speed Nailing process is investigated through an experimental vs numerical framework. Using FORGE® finite-element software, results from joining simulations have been inserted into models in charge of nailed-joint mechanical testings. Numerical Shear and Cross-tensile tests are compared to experimental ones to discuss discrepancy and possible improvements.
Yang, Liqing; Sun, Yuefeng; Li, Ge
2018-06-14
Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.
Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures
Li, A-Bing; Zhang, Wei-Jiang; Guo, Wei-Jun; Wang, Xin-Hua; Jin, Hai-Ming; Zhao, You-Ming
2016-01-01
Abstract Background and objective: Intramedullary nailing is commonly used for treating femoral shaft fractures, one of the most common long bone fractures in adults. The reamed intramedullary nail is considered the standard implant for femoral fractures. This meta-analysis was performed to verify the superiority of reamed intramedullary nailing over unreamed intramedullary nailing in fractures of the femoral shaft in adults. Subgroup analysis of implant failure and secondary procedure was also performed. Methods: Electronic literature databases were used to identify relevant publications and included MEDLINE (Ovid interface), EMBASE (Ovid interface), and the Cochrane Central Register of Controlled Trials (CENTRAL; Wiley Online Library). The versions available on January 30, 2016, were utilized. Only human studies, which were designed as randomized controlled clinical trials, were included. Two authors independently evaluated the quality of original research publications and extracted data from the studies that met the criteria. Results: Around 8 randomized controlled trials involving 1078 patients were included. Reamed intramedullary nailing was associated with shorter time to consolidation of the fracture (SMD = –0.62, 95% CI = –0.89 to –0.35, P < 0.00001), lower secondary procedure rate (OR = 0.25, 95% CI 0.10–0.62, P = 0.003), lower nonunion rate (OR = 0.14, 95% CI = 0.05–0.40, P < 0.01), and lower delayed-union rate (OR = 0.19, 95% CI = 0.07–0.49, P < 0.01) compared to unreamed intramedullary nailing. The 2 groups showed no significant differences in risk of implant failure (OR = 0.50, 95% CI 0.14–1.74, P = 0.27), mortality risk (OR = 0.94, 95% CI 0.19–4.68, P = 0.94), risk of acute respiratory distress syndrome (ARDS; OR = 1.55, 95% CI 0.36–6.57, P = 0.55), or blood loss (SMD = 0.57, 95% CI = –0.22 to 1.36, P = 0.15). Conclusion: Reamed intramedullary nailing is correlated with shorter time to union and lower rates of delayed-union, nonunion, and reoperation. Reamed intramedullary nailing did not increase blood loss or the rates of ARDS, implant failure, and mortality compared to unreamed intramedullary nailing. Therefore, the treatment of femoral fractures using reamed intramedullary nailing is recommended. PMID:27442651
Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.
Dehghan, Niloofar; Schemitsch, Emil H
2017-06-01
Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Comparison of diagnostic methods in the evaluation of onychomycosis.
Haghani, Iman; Shokohi, Tahereh; Hajheidari, Zohreh; Khalilian, Alireza; Aghili, Seyed Reza
2013-04-01
Onychomycosis is a common nail problem, accounting for up to half of all nail diseases. Several nail disorders may mimic the onychomycosis clinically. Therefore, a sensitive, quick, and inexpensive test is essential for screening nail specimens for the administration of the proper drug. The aim of this study was to compare 4 different diagnostic methods in the evaluation of onychomycosis and to determine their sensitivity, specificity, positive predictive value, and negative predictive value. In a cross-sectional study, nail specimens were collected from 101 patients suspected to have onychomycosis during a 14-month period. The nail specimens were examined using potassium hydroxide (KOH) 20 %, KOH-treated nail clipping stained with periodic acid-Schiff (KONCPA), and calcofluor white (CFW) stain, and grew a fungal culture. The culture was chosen as the gold standard for statistical analysis using the McNemar and chi-square tests. Out of 101 patients, 100 (99 %) patients had at least 1 of the 4 diagnostic methods positive for the presence of organisms. The positive rates for the fungal culture, KOH preparation, CFW, and KONCPA were 74.2, 85.1, 91.09, and 99.01 %, respectively. The sensitivity and negative predictive value of KONCPA was 100 %. KONCPA was the most sensitive among the tests and was also superior to other methods in its negative predictive value. KONCPA was easy to perform, rapid, and gave significantly higher rates of detection of onychomycosis compared to the standard methods of KOH preparation and fungal culture. Therefore, KONCPA should be the single method of choice for the evaluation of onychomycosis.
Nail gun injuries in residential carpentry: lessons from active injury surveillance.
Lipscomb, H J; Dement, J M; Nolan, J; Patterson, D; Li, L
2003-03-01
To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing.
Nail gun injuries in residential carpentry: lessons from active injury surveillance
Lipscomb, H; Dement, J; Nolan, J; Patterson, D; Li, L
2003-01-01
Objective: To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. Methods and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Results: Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Conclusions: Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing. PMID:12642553
[Clinico-mycological study of onychomycosis in elderly patients].
Rodríguez-Soto, M E; Fernández-Andreu, C M; Moya Duque, S; Rodríguez Díaz, R M; Martínez-Machín, G
1993-01-01
Physical examination of nails was carried out in 210 elderly patients and nail scrapings were obtained from onychomycosis suggested lesions in order to determine their causative agents, incidence and clinical characteristics. Diagnostic was confirmed by the isolation of the agents from 74 patients, mainly from toe-nails (incidence 35.2). Tinea pedis occurred in 25% of the cases and Diabetes mellitus was the most prevalent associated disease and the most frequent clinical characteristics were the thickening, the opacity and the presence of longitudinal strias in the surface of the nails. It was compared the results obtained by microscopic examination and by culture. Trichophyton rubrum was the most common dermatophyte isolated; Candida parapsilosis was dominant among Candida species.
Experimental investigation of internal short circuits in lithium-ion batteries
NASA Astrophysics Data System (ADS)
Poramapojana, Poowanart
With outstanding performance of Lithium-ion batteries, they have been widely used in many applications. For hybrid electric vehicles and electric vehicles, customer concerns of battery safety have been raised as a number of car accidents were reported. To evaluate safety performance of these batteries, a nail penetration test is used to simulate and induce internal short circuits instantaneously. Efforts to explain failure mechanisms of the penetration using electrochemical-thermal coupled models have been proposed. However, there is no experimental validation because researchers lack of a diagnostic tool to acquire important cell characteristics at a shorting location, such as shorting current and temperature. In this present work, diagnostic nails have been developed to acquire nail center temperatures and shorting current flow through the nails during nail penetration tests. Two types of cylindrical wall structures are used to construct the nails: a double-layered stainless steel wall and a composite cylindrical wall. An inner hollow cylinder functions as a sensor holder where two wires and one thermocouple are installed. To study experimental reproducibility and repeatability of experimental results, two nail penetration tests are conducted using two diagnostic nails with the double-layered wall. Experimental data shows that the shorting resistance at the initial stage is a critical parameter to obtain repeatable results. The average shorting current for both tests is approximately 40 C-rate. The fluctuation of the shorting current is due to random sparks and fire caused loose contacts between the nail and the cell components. Moreover, comparative experimental results between the two wall structures reveal that the wall structure does not affect the cell characteristics and Ohmic heat generation of the nail. The wall structure effects to current measurements inside the nail. With the composite wall, the actual current redistribution into the inner wall is found to be a sinusoidal waveform.
Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study.
Mukherjee, Sagnik; Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam
2017-04-01
Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed. There was no difference between the two modalities in terms of fracture union. Complications were lesser but more serious in case of plating. Patient satisfaction was more with plating.
Complications of the Intramedullary Skeletal Kinetic Distractor (ISKD) in distraction osteogenesis.
Lee, Dong Hoon; Ryu, Keun Jung; Song, Hae Ryong; Han, Soo-Hong
2014-12-01
The Intramedullary Skeletal Kinetic Distractor (ISKD) (Orthofix Inc, Lewisville, TX, USA) is an intramedullary device designed for more comfortable limb lengthening than that with external fixators; lengthening is achieved with this nail using rotational oscillation between two telescoping sections. However, the degree to which this device achieves this goal and its complication rate have not been fully documented. We determined (1) the frequency with which distraction was not achieved at the desired rate, (2) whether pain differed between patients with normally and abnormally distracting nails, (3) risk factors for abnormal nails, and (4) other complications. We analyzed 35 lengthening segments (26 femurs, nine tibias) in 19 patients. Mean length achieved was 47 mm. Femoral nails were categorized into four groups according to distraction rate: normal, runaway (unintentionally faster rate [> 1.5 mm/day]), difficult-to-distract (slower rate [< 0.8 mm/day] requiring manual manipulation but not requiring general anesthesia), and nondistracting (slower rate [< 0.8 mm/day] requiring manual manipulation under general anesthesia or reosteotomy). Possible risk factors, including age, BMI, preoperative thigh circumferences, degree of intramedullary overreaming, and length of the thicker portion of the nail within the distal fragment, were compared among groups. VAS pain scores were compared among groups under three conditions: rest, physiotherapy, and distraction motion. Complications were also analyzed. Minimum followup was 15 months (mean, 26 months; range, 15-38 months) after first-stage surgery. Abnormal distraction rate was observed in 21 of 35 segments (60%; 17 femurs, four tibias). VAS pain scores showed no differences among groups during rest or physiotherapy but were higher (p = 0.02) in the problematic nails (7-8 points) versus normal nails (3 points) during distraction. Only mean length of the thicker portion of the nail within the distal fragment differed between normally and abnormally distracting nails (95 mm versus 100 mm; p = 0.03), although this was unlikely to be clinically important. Complications occurred in 10 patients (53%), including five with decreased ankle ROM during distraction, four with delayed bone healing, and one with mechanical device failure during distraction. Rate control was difficult to achieve with the ISKD nail for femoral and tibial lengthenings, complications were relatively common, and among patients in whom rate control was not achieved, pain levels were high. Based on our findings, we believe that surgeons should avoid use of this nail. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Yeoh, David; Goddard, Richard; Macnamara, Paul; Bowman, Nicholas; Miles, Kim; East, Debra; Butler-Manuel, Adrian
2008-08-01
The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Orthodynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland). All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically. The mean inpatient stay for the Mayday nail group was 23 days (range 8-45 days) compared with 76 days (range 34-122) for the external fixation group (p<0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p<0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups. Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.
Influence of Femoral Component Design on Retrograde Femoral Nail Starting Point.
Service, Benjamin C; Kang, William; Turnbull, Nathan; Langford, Joshua; Haidukewych, George; Koval, Kenneth J
2015-10-01
Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.
Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba
2014-08-01
Intramedullary nails are the primary choice for treating long bone fractures. However, complications following nail surgery including non-union, delayed union, and fracture of the bone or the implant still exist. Reducing nail stiffness while still maintaining sufficient stability seems to be the ideal solution to overcome the abovementioned complications. In this study, a new hybrid concept for nails made of carbon fibers/flax/epoxy was developed in order to reduce stress shielding. The mechanical performance of this new implant in terms of fracture stability and load sharing was assessed using a comprehensive non-linear FE model. This model considers several mechanical factors in nine fracture configurations at immediately post-operative, and in the healed bone stages. Post-operative results showed that the hybrid composite nail increases the average normal force at the fracture site by 319.23N (P<0.05), and the mean stress in the vicinity of fracture by 2.11MPa (P<0.05) at 45% gait cycle, while only 0.33mm and 0.39mm (P<0.05) increases in the fracture opening and the fragments' shear movement were observed. The healed bone results revealed that implantation of the titanium nail caused 20.2% reduction in bone stiffness, while the composite nail lowered the stiffness by 11.8% as compared to an intact femur. Our results suggest that the composite nail can provide a preferred mechanical environment for healing, particularly in transverse shaft fractures. This may help bioengineers better understand the biomechanics of fracture healing, and aid in the design of effective implants. Copyright © 2014. Published by Elsevier Ltd.
Percutaneous osteoplasty with a bone marrow nail for fractures of long bones: experimental study.
Nakata, Kouhei; Kawai, Nobuyuki; Sato, Morio; Cao, Guang; Sahara, Shinya; Tanihata, Hirohiko; Takasaka, Isao; Minamiguchi, Hiroyuki; Nakai, Tomoki
2010-09-01
To develop percutaneous osteoplasty with the use of a bone marrow nail for fixation of long-bone fractures, and to evaluate its feasibility and safety in vivo and in vitro. Six long bones in three healthy swine were used in the in vivo study. Acrylic cement was injected through an 11-gauge bone biopsy needle and a catheter into a covered metallic stent placed within the long bone, creating a bone marrow nail. In the in vitro study, we determined the bending, tug, and compression strengths of the acrylic cement nails 9 cm long and 8 mm in diameter (N = 10). The bending strength of the artificially fractured bones (N = 6) restored with the bone marrow nail and cement augmentation was then compared with that of normal long bones (N = 6). Percutaneous osteoplasty with a bone marrow nail was successfully achieved within 1 hour for all swine. After osteoplasty, all swine regained the ability to run until they were euthanized. Blood tests and pathologic findings showed no adverse effects. The mean bending, tug, and compression strengths of the nail were 91.4 N/mm(2) (range, 75.0-114.1 N/mm(2)), 20.9 N/mm(2) (range, 6.6-30.4 N/mm(2)), and 103.0 N/mm(2) (range, 96.3-110.0 N/mm(2)), respectively. The bending strength ratio of artificially fractured bones restored with bone marrow nail and cement augmentation to normal long bone was 0.32. Percutaneous osteoplasty with use of a bone marrow nail and cement augmentation appears to have potential in treating fractures of non-weight-bearing long bones. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.
A Pilot Study: Nailing Indian Elections with the Indelible Ink Mark
Abraham, Anil; Roga, Gillian; Thomas, Naveen
2015-01-01
Context: The indelible ink that's used in our elections was developed by National Physical Laboratories (NPL), Delhi in 1962, and has been used ever since. Though formulated by NPL, it is manufactured by Mysore Paints and Varnish Ltd. owned by the Karnataka Government. Earlier, the ink mark was applied on the cuticle but with effect from February 01, 2006 the ink is applied on the voter's left index fingernail from the distal end proximally until the cuticle using an applicator. This idea of the ink mark applied during elections was used as a simple tool to measure the rate of nail growth in a busy outpatient department of a Tertiary Hospital in South India. Aims: To assess the feasibility of using the ink mark during elections as a method of obtaining data of nail growth across the spectrum of the entire country. Subjects and Methods: In 74 patients presenting to a hospital, the rate of nail growth was measured. The voter's mark on the left index fingernail of patients during the recent elections was used as a marker for measuring the length of the nail. Results: The average rate of nail growth was 0.113 mm/day. The rate of nail growth was found to be more in females, younger individuals, pregnancy, patients on nutritional supplementation, psoriasis. Conclusion: This study which was conducted on 74 patients using the election ink mark successfully confirmed the possibility of using it as an efficient tool in measuring the rate of nail growth. The findings revealed the slightly higher rate of nail growth as compared to a study done by Rani et al. However, the limited sample size in this study was the major limitation. PMID:26677268
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beres, W.; Koul, A.K.
1994-09-01
Stress intensity factors for thru-thickness and thumb-nail cracks in the double edge notch specimens, containing two different notch radius (R) to specimen width (W) ratios (R/W = 1/8 and 1/16), are calculated through finite element analysis. The finite element results are compared with predictions based on existing empirical models for SIF calculations. The effects of a change in R/W ratio on SIF of thru-thickness and thumb-nail cracks are also discussed. 34 refs.
Olsen, Michael; Goshulak, Peter; Crookshank, Meghan C; Moktar, Joel; Brazda, Ignace J; Schemitsch, Emil H; Zdero, Radovan
2018-04-03
The goal of this study was to compare a 3-hole vs. a 4-hole sliding hip screw (SHS) in the presence of a retrograde intramedullary (RIM) nail for fixing intertrochanteric and comminuted midshaft femur fractures. Mechanical tests were performed on 10 matched pairs of human cadaveric femurs that were osteotomized and then fixed using a 3-hole SHS vs. the traditional "gold standard" 4-hole SHS in the presence of a RIM nail. Data showed no differences between the 3-hole SHS with RIM nail vs. 4-hole SHS with RIM nail for stiffness (281 +/- 127 vs. 260 +/- 118 N/mm, p=0.76), clinical failure at 10 mm of hip displacement (2014 +/- 363 vs. 2134 +/- 614 N, p=0.52), or ultimate mechanical failure (3476 +/- 776 vs. 3669 +/- 755 N, p=0.12). For this fracture pattern, a 3-hole SHS with RIM nail may be a suitable surgical alternative to the traditional "gold standard" method, since it provides the same biomechanical properties while potentially reducing surgical time, blood loss, and hardware used. Level III biomechanical study.
The Chinese Nail Murders: forensic medicine in Imperial China.
Summers, W. C.
1999-01-01
Robert van Gulik was a respected Dutch sinologist and author who first translated a collection of traditional Chinese detective stories into English and then created additional fictional stories based on the same characters and setting in the Tang dynasty. One of these stories, The Chinese Nail Murders, draws on van Gulik's professional interest in law and his knowledge of early Chinese works on forensic medicine. This novel develops a common theme in Chinese detective fiction, murder by a nail wound to the head. The difficulty in detection of this mode of violence posed a particular problem for the examining magistrate because postmortem examination was mostly limited to external observations. This essay compares the development of Chinese and Western forensic medicine in the context of the nail murder motif. PMID:11138936
The fracture properties and mechanical design of human fingernails.
Farren, L; Shayler, S; Ennos, A R
2004-02-01
Fingernails are a characteristic feature of primates, and are composed of three layers of the fibrous composite keratin. This study examined the structure and fracture properties of human fingernails to determine how they resist bending forces while preventing fractures running longitudinally into the nail bed. Nail clippings were first torn manually to examine the preferred crack direction. Next, scissor cutting tests were carried out to compare the fracture toughness of central and outer areas in both the transverse and longitudinal direction. The fracture toughness of each of the three isolated layers was also measured in this way to determine their relative contributions to the toughness. Finally, the structure was examined by carrying out scanning electron microscopy of free fracture surfaces and polarized light microscopy of nail sections. When nails were torn, cracks were always diverted transversely, parallel to the free edge of the nail. Cutting tests showed that this occurred because the energy to cut nails transversely, at approximately 3 kJ m(-2), was about half that needed (approx. 6 kJ m(-2)) to cut them longitudinally. This anisotropy was imparted by the thick intermediate layer, which comprises long, narrow cells that are oriented transversely; the energy needed to cut this layer transversely was only a quarter of that needed to cut it longitudinally. In contrast the tile-like cells in the thinner dorsal and ventral layers showed isotropic behaviour. They probably act to increase the nail's bending strength, and as they wrap around the edge of the nail, they also help prevent cracks from forming. These results cast light on the mechanical behaviour and care of fingernails.
Physics of nail conditions: why do ingrown nails always happen in the big toes?
Rauch, Cyril; Cherkaoui-Rbati, Mohammed
2014-10-16
Although surgical treatment of nail conditions can be traced back centuries to the writings of Paul Aegineta (625-690 AC), little is known about the physical laws governing nail growth. Such a poor understanding together with the increasing number of nail salons in the high street should raise legitimate concerns regarding the different procedures applied to nails. An understanding of the physics of nail growth is therefore essential to engage with human medicine and to understand the aetiology of nail conditions. In this context, a theory of nail plate adhesion, including a physical description of nail growth can be used to determine the transverse and longitudinal curvatures of the nail plate that are so important in the physical diagnosis of some nail conditions. As a result physics sheds light on: (a) why/how nails/hooves adhere strongly, yet grow smoothly; (b) why hoof/claw/nail growth rates are similar across species; (c) potential nail damage incurred by poor trimming; (d) the connection between three previously unrelated nail conditions, i.e. spoon-shaped, pincer and ingrown nails and; last but not least, (e) why ingrown nails occur preferentially in the big toes.
Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study
Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam
2017-01-01
Introduction Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. Aim To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. Materials and Methods A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Results Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed. Conclusion There was no difference between the two modalities in terms of fracture union. Complications were lesser but more serious in case of plating. Patient satisfaction was more with plating. PMID:28571220
Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A
2017-06-01
Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at p<0.05. A total of 316 patients were included. Piriformis entry nails made up the majority (n=141), followed by retrograde (n=108), then trochanteric entry nails (n=67). Univariate regression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, p<0.05). Using revision as an endpoint, trochanteric entry nails also had a significantly lower revision rate, even when controlling for all other variables (p<0.05). Comparative, objective comparisons between DFV between different nails based on entry point revealed that trochanteric nails had a significantly lower DFV and a lower revision rate, even after regression analysis. However, this is not to state that the other nail types exhibited abnormal DFV. Translation to the clinical impact of a few degrees of DFV is also unknown. Future studies to more in-depth study the intricacies of femoral version may lead to improved technology in addition to potentially improved clinical outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola
2017-08-24
In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The treatment protocol based on use of biaxial Medoff sliding plate for unstable pertrochanteric and uniaxial Medoff sliding plate for subtrochanteric fractures reduced the risk of severe technical complications compared to using the treatment protocol based on dynamic hip screw and intramedullary nail.
Guo, J J; Tang, N; Yang, H L; Tang, T S
2010-07-01
We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively).After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.
Madnani, Nina A; Khan, Kaleem J
2012-01-01
The nail as an anatomic structure protects the terminal phalanx of the digit from injury. Historically, it has served as a tool for protection and for survival. As civilizations developed, it attained the additional function of adornment. Nail beautification is a big industry today, with various nail cosmetics available, ranging from nail hardeners, polishes, extensions, artificial/sculpted nails, and nail decorations. Adverse events may occur either during the nail-grooming procedure or as a reaction to the individual components of the nail cosmetics. This holds true for both the client and the nail technician. Typically, any of the procedures involves several steps and a series of products. Separate "nail-bars" have been set up dedicated to serve women and men interested in nail beautification. This article attempts to comprehensively inform and educate the dermatologist on the services offered, the products used, and the possible/potential adverse effects related to nail-grooming and nail cosmetics.
Treating nailbiting: a comparative analysis of mild aversion and competing response therapies.
Silber, K P; Haynes, C E
1992-01-01
This study compared two methods of treating nail-biting. One method involved the use of a mild aversive stimulus in which subjects painted a bitter substance on their nails, and the other required the subject to perform a competing response whenever they had the urge to bite or found themselves biting their nails. Both methods included self-monitoring of the behaviour, and a third group of subjects performed self-monitoring alone as a control condition. The study lasted four weeks. Twenty-one subjects, seven per group, participated. Both methods resulted in significant improvements in nail length, with the competing response method showing the most beneficial effect. There was no significant improvement for the control group. The competing response condition also yielded significant improvements along other dimensions such as degree of skin damage and subjects own ratings of their control over their habit. These were not seen for the other two conditions. The benefits of this abridged version of Azrin and Nunn's (Behaviour Research and Therapy, 11, 619-628, 1973) habit reversal method in terms of treatment success, use of therapist time and client satisfaction, are discussed.
2014-01-01
Objective The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. Methods A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Results Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. Conclusion RSIN may be a reliable and practical alternative method for the treatment of long bone fractures. PMID:25047454
Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei
2014-07-21
The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.
Dermoscopy in the Evaluation of Nail Disorders
Alessandrini, Aurora; Starace, Michela; Piraccini, Bianca Maria
2017-01-01
Nail dermoscopy was initially used only in the assessment of nail pigmentation, but now it is widely utilized for the evaluation of many nail disorders. In daily practice, dermoscopy may confirm clinical diagnoses and guides in the management of nail diseases and treatments, permitting a better visualization of symptoms. Dry dermoscopy is required for evaluation of the nail plate surface, while gel as an interface is necessary for assessment of nail pigmentation and onycholysis, as well as for the evaluation of the distal nail margin. In this review, we describe the dermoscopic features of the most important nail disorders, looking at the different areas of the nail. Dermatoscopic changes that usually accompany specific nail diseases are also reviewed. PMID:28560217
Smith, Kelly A; Hao, Jinsong; Li, S Kevin
2009-06-01
Transport across the human nail under hydration can be modeled as hindered transport across aqueous pore pathways. As such, nail permselectivity to charged species can be manipulated by changing the ionic strength of the system in transungual delivery to treat nail diseases. The present study investigated the effects of ionic strength upon transungual passive and iontophoretic transport. Transungual passive and anodal iontophoretic transport experiments of tetraethylammonium ion (TEA) were conducted under symmetric conditions in which the donor and receiver had the same ionic strength in vitro. Experiments under asymmetric conditions were performed to mimic the in vivo conditions. Prior to the transport studies, TEA uptake studies were performed to assess the partitioning of TEA into the nail. Permselectivity towards TEA was inversely related to ionic strength in both passive and iontophoretic transport. The permeability and transference number of TEA were higher at lower ionic strengths under the symmetric conditions due to increased partitioning of TEA into the nail. Transference numbers were smaller under the asymmetric conditions compared with their symmetric counterparts. The results demonstrate significant ionic strength effects upon the partitioning and transport of a cationic permeant in transungual transport, which may be instrumental in the development of transungual delivery systems.
Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.
Patino, Juan Martin
2015-08-01
The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Nishizawa, A; Satoh, T; Yokozeki, H
2013-02-01
Lichen planus (LP) is a common skin disorder of unknown aetiology that affects the skin, mucous membranes and nails. Although metal allergies have been implicated in the development of oral LP (OLP), the contribution of these allergies to nail LP (NLP) has yet to be studied in detail. To elucidate the link between metal allergy and NLP. We retrospectively analysed 115 LP patients with respect to the contribution of metals to either NLP or OLP. We also attempted to detect the specific metals involved in these nail lesions. Of the 79 patients that received a metal patch test (PT), 24 (30%) were positive for at least one of the metal compounds tested. Notably, the prevalence of positive reactions to metals in the NLP patients was significantly higher as compared with the OLP patients (59% vs. 27%, P < 0.05). Among the 10 PT-positive patients with NLP, improvement of the skin lesions was seen in six of the patients after removal of dental materials containing causative metals or systemic disodium cromoglycate therapy. On the other hand, only 3 of 16 PT-positive patients with OLP exhibited improvement after the removal of dental materials. Causative metals in the dental fillings/braces were detected in the involved nail tissues. This study suggests that metal allergies are more closely associated with NLP vs. OLP, and that deposited metals in the nail apparatus contribute to the development of lichenoid tissue reactions in the nail bed and matrix. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.
Göktay, Fatih; Altan, Zeynep Müzeyyen; Talas, Anıl; Akpınar, Esma; Özdemir, Ekin Özge; Aytekin, Sema
2016-01-01
Patient anxiety about nail surgery relates mainly to pain associated with needle puncture, anesthetic flow during the procedure, and postoperative care, as well as possible past traumatic experience. The aims of this study were to compare anxiety levels among patients undergoing nail surgery and skin punch biopsy and to assess the effects of demographic characteristics on anxiety. Forty-eight consecutive patients who were referred to a dermatological surgery unit for nail surgery intervention (group 1) and 50 age- and sex-matched patients referred to the same unit for skin punch biopsy (group 2) were enrolled in the study. Patients' anxiety levels were measured using Spielberger's State-Trait Anxiety Inventory. There was no significant difference in median anxiety level between group 1 (42.00; interquartile range, 6.50) and group 2 (41.00; interquartile range, 8.25) (P = .517). The demographic factors of patient sex, educational status, and prior surgery showed no significant effects on anxiety levels. Nail surgery does not seem to cause significantly greater anxiety than skin punch biopsy. © The Author(s) 2015.
Park, Sung-Ae; Gwak, Sugyeong
2014-01-01
Objectives This study aimed to evaluate occupational symptoms and chemical exposures of nail salon technicians. Methods Work-related symptoms of nail salon technicians in Daegu City were surveyed using a researcher-administered questionnaire, and responses were compared to those of non-exposed office workers as controls. Personal exposure level of airborne volatile organic compounds was also monitored using passive samplers. Results A total of 159 subjects in 120 salons were interviewed. Average work-shift concentrations of 13 chemicals were measured for 50 workers from 30 salons using personal passive samplers. The most frequently reported respiratory or neurologic symptoms by nail shop technicians compared to controls were nose irritation (odds ratio [OR], 54.0; confidence interval [CI], 21.6 to 134.8), followed by headache (OR, 9.3; CI, 4.7 to 18), and throat irritation (OR, 4.3; CI, 2.2 to 8.5). For eyes and skin, 92% of respondents complained eye irritation (OR, 13.1; CI, 5.7 to 30.1). In musculoskeletal symptoms, workers reported pain or discomfort in shoulders (OR, 20.3; CI, 7.7 to 54) and neck (OR, 19.7; CI, 8.9 to 43.6). From personal measurements, the proportion of exceeding the Korean Occupational Exposure Limit was the highest for acetone with 64%, followed by toluene (50%), butyl acetate (46%), and methyl methacrylate (12%). However, the service was being provided without a proper ventilation system in most surveyed shops. Conclusions Based on these findings, it is warranted to have appropriate local exhaust ventilation place to ensure adequate health protection of nail shop technicians as well as customers. At the same time, greater policy interests are warranted in nail care business to protect health of both workers and customers. PMID:24921020
Esan, O; Ikem, I C; Orimolade, E A; Esan, O T
2014-06-01
This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at p<0.05. A total of 280 patients were studied out of which two hundred and twenty-one patients had long bone diaphyseal fractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.
How precise is the PRECICE compared to the ISKD in intramedullary limb lengthening?
Vogt, Björn; Tretow, Henning L; Schuhknecht, Britta; Gosheger, Georg; Horter, Melanie J; Rödl, Robert
2014-01-01
Background and purpose The PRECICE intramedullary limb lengthening system uses a new technique with a magnetic rod and a motorized external remote controller (ERC) with rotational magnetic field. We evaluated the reliability and safety of the PRECICE system. Methods We compared our preliminary results with PRECICE in 24 patients (26 nails) with the known difficulties in the use of mechanical lengthening devices such as the ISKD. We used the Paley classification for evaluation of problems, obstacles, and complications. Results 2 nails were primarily without function, and 24/26 nails lengthened over the desired distance. Lengthening desired was 38 mm and lengthening obtained was 37 mm. There were 2 nail breakages, 1 in the welding seam and 1 because of a fall that occurred during consolidation. ERC usage was problematic mostly in patients with femoral lengthening. Adjustment of the ERC was necessary in 10 of 24 cases. 15 cases had implant-associated problems, obstacles were seen in 5 cases, and complications were seen in each of 4 cases. Interpretaion The reliability of the PRECICE system is comparable to that of other intramedullary lengthening devices such as the ISKD. The motorized external remote controller and its application by the patients is a weak point of the system and needs strict supervision. PMID:24758320
Jefferson, Julie; Rich, Phoebe
2012-01-01
Nail cosmetics are used by millions of people worldwide who desire smooth, lustrous nails. The nail cosmetic industry continues to expand to meet increasing consumer demand. In 2011 alone, consumers spent $6.6 billion on nail salon services. Although nail cosmetics are relatively safe, poor application techniques can promote disease, deformity, and allergic and irritant contact dermatitis. The foundation for managing nail cosmetic problems is prevention through education. Familiarity with the procedures and materials used in the nail cosmetic industry is necessary in order to recommend safe nail care strategies. © 2012 Wiley Periodicals, Inc.
Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit
2015-07-01
Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial shaft fractures. Moderate confidence evidence showed that unreamed nailing may reduce the likelihood of reoperation compared with external fixation (network odds ratio [OR], 0.38; 95% CI, 0.23-0.62; p < 0.05), although not necessarily compared with reamed nailing (direct OR, 0.74; 95% CI, 0.45-1.24; p = 0.25). Only low- or very low-quality evidence informed the primary outcome for other treatment comparisons, such as those involving internal plate fixation, Ilizarov external fixation, and Ender nailing. Method ranking based on reoperation data showed that unreamed nailing had the highest probability of being the best treatment, followed by reamed nailing, external fixation, and plate fixation. CIs around pooled estimates of malunion and infection risk were very wide, and therefore no conclusive results could be made based on these data. Current evidence suggests that intramedullary nailing may be superior to other fixation strategies for open tibial shaft fractures. Use of unreamed nails over reamed nails also may be advantageous in the setting of open fractures, but this remains to be confirmed. Unfortunately, these conclusions are based on trials that have had high risk of bias and poor precision. Larger and higher-quality head-to-head randomized controlled trials are required to confirm these conclusions and better inform clinical decision-making. Level I, therapeutic study.
Georgiannos, D; Lampridis, V; Bisbinas, I
2017-02-01
The management of ankle fractures in the elderly remains unpredictable, secondary to their various co-morbidities. Although tibiotalocalcaneal (TTC) nailing has been an effective option for ankle arthrodesis due to ankle arthritis or Charcot arthropathy there are few reports regarding the use of TTC nail for the treatment of ankle fractures. Aim of this study was to compare the results of ORIF versus TTC nailing for the treatment of unstable ankle fractures in the elderly. We hypothesized that the elderly may benefit from TTC nailing, as it allows the patient to be mobilized immediately after surgery and minimizes the risk of wound or bone problems. This was a prospective, randomized-controlled, comparative study. Between 2009 and 2015, 43 patients were treated with a TTC nail (Group A) and 44 with ORIF (Group B). The Olerud-Molander ankle score was obtained and intraoperative-postoperative complications, length of hospital stay, mobility status and reoperation rate were recorded. The nail fixation was performed with the TrigenR hindfoot nail after closed reduction. ORIF was performed, using a 1/3 tubular plate and 3.5mm screws for the lateral malleolus and two 4.0 mm cannulated screws for the medial. Mortality rate at one year was 13.9% for Group A and 18.1% for Group B. Mean follow-up was 14 months (12-18m). There were no intraoperative complications. Three complications in Group A (8.1%) and twelve (33.3%) in Group B were encountered postoperatively (p<0.05). There was significant shorter hospital stay in Group A (5.2±3.1d) than in Group B (8.4±5.2d). In Group A, 28 patients returned to their pre-injury mobility status (75.6%) while 9 declined one level of the mobility scale (24.3%). In Group B, 26 patients remained at the same mobility level (72.2%) and 10 declined one level (27.7%). There was no significant difference between the postoperative OMAS scores in the two Groups (56.9±9.85 and 56.6±9.3 respectively). We believe that TTC nailing is a safe and effective method of treatment of unstable ankle fractures in the elderly because it has a low risk of complications and restores function and mobility allowing an immediate return to full weight-bearing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Nail involvement in patients with moderate-to-severe alopecia areata treated with oral tofacitinib.
Lee, Ji Su; Huh, Chang-Hun; Kwon, Ohsang; Yoon, Hyun-Sun; Cho, Soyun; Park, Hyun-Sun
2018-05-07
A few anecdotal case reports demonstrated that tofacitinib improved nail changes associated with AA. To investigate nail changes in patients with AA treated with tofacitinib and evaluate the relationship between nail and hair responses to tofacitinib. This is a retrospective study of 33 adult patients with moderate-to-severe AA treated with oral tofacitinib monotherapy for at least 4 months. Fifteen patients had nail involvement and demonstrated more severe hair loss than those without nail involvement (p = .040). However, there was no significant difference in hair regrowth between two groups. Of 15 patients with nail involvement, 11 (73.3%) showed improvement regardless of type of nail change; the first improvement was observed at a median of 5 months (range, 1-11) after administration. Nail improvement was associated with neither initial severity of hair loss nor hair response to tofacitinib. Nail improvement tended to occur later than hair regrowth. Oral tofacitinib monotherapy improves nail involvement associated with AA. Nail involvement is not a poor prognosis factor in hair regrowth with tofacitinib treatment and there is no evident relationship between nail and hair responses.
Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O
2013-12-01
AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.
Jiang, Liangjun; Pan, Zhijun; Zheng, Qiang
2014-01-01
Augmentation plating has been used successfully to treat hypertrophic non-union after nail fixation. This study compared the efficacy of augmentation plating and exchange plating for treating hypertrophic non-union of femoral shaft fracture after intramedullary nail fixation. A total of 12 patients received augmentation plating and 15 patients received exchange plating as treatment for femoral shaft hypertrophic non-union. The procedures were conducted at our medical centre between January 2005 and January 2012. Clinical follow-up was conducted at 2 weeks, 1 month and then monthly until union was achieved to compare union time, operation time, bleeding and complications between the two groups. All patients underwent follow-up examinations until fracture union was achieved. The average length of follow-up time after the second treatment was (18.37 ± 3.28) months. The time needed for union was (4.17 ± 0.94) months in the augmentation plating group and (5.33 ± 1.72) months in the exchange plating group. The operation time was (90.00 ± 17.58) minutes in the augmentation plating group and (160.00 ± 25.35) minutes in the exchange plating group. The amount of blood loss during the operation was (270.00 ± 43.32) ml in the augmentation plating group and (530.00 ± 103.65) ml in the exchange plating group. Both groups showed significant difference (P < 0.05) in their results. No complications were reported after the second operation. Augmentation plating after nail fixation could remove local rotation instability, facilitate simple operation, create minimal damage and enable exercise for early functional recovery. Therefore, augmentation plating is excellent for treating hypertrophic non-union after nail fixation in femoral shaft fracture.
Baswan, Sudhir; Kasting, Gerald B.; Li, S. Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan
2016-01-01
The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. PMID:28098391
Baswan, Sudhir; Kasting, Gerald B; Li, S Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan
2017-05-01
The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. © 2017 Blackwell Verlag GmbH.
Arsenic (As) is found naturally in the geological strata within the Ba Men Region of West Central Inner Mongolia, China. Residents here have been chronically exposed to a wide range of drinking water As levels for more than 20 years. Nails and drinking water samples were collec...
Genetics Home Reference: nonsyndromic congenital nail disorder 10
... Nails MalaCards: nail disorder, nonsyndromic congenital, 10 Merck Manual Consumer Version: Deformities, Dystrophies, and Discoloration of the Nails Orphanet: Autosomal recessive nail dysplasia Patient Support ...
Ni, Ming; Niu, Wenxin; Wong, Duo Wai-Chi; Zeng, Wei; Mei, Jiong; Zhang, Ming
2016-08-01
Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based on finite element (FE) method. The FE model of clavicle was reconstructed from CT images of a male volunteer. A mid-shaft fracture gap was created in the intact clavicle. Three fixation styles were simulated including locking plate (LP), anatomic intramedullary nail (CRx), and straight intramedullary nail (RCP). Two loading scenarios (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction, while the sternal end was fixed. Under both conditions, the LP was the stiffest, followed by the CRx, and the RCP was the weakest. LP also displayed a more evenly stress distribution for both implant and bone. RCP had a higher stress compared with CRx in both conditions. Moreover, all implants sustained higher stress level under the loading condition of bending than compression. The plate fixation significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for the mid-shaft clavicle fracture. The CRx is an alternative device to treat clavicle shaft fracture, but the shoulder excessive activities should be avoided after operation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of sand-based water filters for point-of-use arsenic removal in China.
Smith, Kate; Li, Zhenyu; Chen, Bohan; Liang, Honggang; Zhang, Xinyi; Xu, Ruifei; Li, Zhilin; Dai, Huanfang; Wei, Caijie; Liu, Shuming
2017-02-01
Contamination of groundwater wells by arsenic is a major problem in China. This study compared arsenic removal efficiency of five sand-based point-of-use filters with the aim of selecting the most effective filter for use in a village in Shanxi province, where the main groundwater source had arsenic concentration >200 μg/L. A biosand filter, two arsenic biosand filters, a SONO-style filter and a version of the biosand filter with nails embedded in the sand were tested. The biosand filter with embedded nails was the most consistent and effective under the study conditions, likely due to increased contact time between water and nails and sustained corrosion. Effluent arsenic was below China's standard of 50 μg/L for more than six months after construction. The removal rate averaged 92% and was never below 86%. In comparison, arsenic removal for the nail-free biosand filter was never higher than 53% and declined with time. The arsenic biosand filter, in which nails sit in a diffuser basin above the sand, performed better but effluent arsenic almost always exceeded the standard. This highlights the positive impact on arsenic removal of embedding nails within the top layer of biosand filter sand and the promise of this low-cost filtration method for rural areas affected by arsenic contamination. Copyright © 2016 Elsevier Ltd. All rights reserved.
... appearance of the thumbnails. Long-term exposure to moisture or nail polish can cause nails to peel ... nail, if your nails are constantly exposed to moisture, or whether you are always picking at your ...
[Should one choose the nail or the plate in treating a leg fracture?].
Vives, P; Massy, E; Dubois, P; Decoopmann, P
1975-12-01
The authors have analysed the results of 126 tibial fractures treated by blind nailing with reaming and 112 tibial fractures treated by plating. They noted 5 septic complications after nailing, after plating, one non-union after nailing and 12 after plating, 3 malunions after nailing and 2 after plating. The cases treated by nailing united earlier. The Authors conclude that nailing is a more fiable technique than plating, and that the only fractures which should be plated are those which are not fit for nailing.
Damage control and intramedullary nailing for long bone fractures in polytrauma patients.
Patka, Peter
2017-06-01
The early fracture treatment in patients with multiple injuries should be focused on damage control. The fracture type and its location, local soft tissue condition as well as the patient's physiological condition shall determine the time and type of fracture treatment. Prevention of local and systemic complications must be immediately considered and included in the treatment planning. The use of external fixator (ExFix), which will be replaced by IM-implants in most cases at a later stage, provides adequate temporary fracture stabilization with less collateral damage. Good clinical results can be expected in patients with long bone fractures if the principles of damage control surgery are applied and local complications are prevented through proper reduction, firm fixation, early soft tissue reconstruction, and early rehabilitation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Arthrodesis of the knee using a custom-made intramedullary coupled device.
White, S P; Porteous, A J; Newman, J H; Mintowt-Czyz, W; Barr, V
2003-01-01
Nine patients underwent arthrodesis of the knee using customised coupled nail (the Mayday arthrodesis nail), five after infected arthroplasty, one following failed arthrodesis, one for intractable anterior knee pain, one for Charcot instability and one after trauma. Comparison was made with 17 arthrodeses, eight undertaken using external fixation, four with dual compression plates, and five with long Kütntscher nails. Union was achieved in all patients (100%) at a mean time of ten months using the customised implant. There were no complications despite early weight-bearing. No further procedures were required. This contrasted with a rate of union of 53% and a complication rate of 76% with alternative techniques. Of this second group, 76% required a further operative procedure. We compared the Mayday arthrodesis nail with other techniques of arthrodesis of the knee. The differences in the need for further surgery and occurrence of complications were statistically significant (p < 0.001), and differences in the rate of nonunion and inpatient stay of less than three weeks were also significant (p < 0.05) using Fisher's exact test. We conclude that a customised coupled intramedullary nail can give excellent stability allowing early weight-bearing, and results in a high rate of union with minimal postoperative complications.
Lakshmi Priya, Malarveni Damodaran; Geetha, Arumugam
2011-05-12
Autism is a complex disorder which is heterogeneous in nature with varying degrees of severity for which no specific biological marker has been identified. Several studies are focused on the hair and nail protein pattern as a means to identify specific markers for the diagnosis of many childhood disorders like mental retardation, dyslexia, trichorrhexis nodosa, trichothiodystrophy, etc. The present study is one such approach in investigating the electrophoretic pattern of proteins in hard keratins and their percentage of nitration since nitric oxide production and nitration of tyrosine residues in proteins of autistic children are the emerging topic of research. We extracted and quantified the proteins from hair and nail samples of autistic children with different grades of severity, [low functioning autism (LFA), medium functioning autism (MFA), and high functioning autism (HFA)] and also from age- and sex-matched normal children. Protein pattern was evaluated by one-dimensional SDS-PAGE and the separated proteins were made to cross react with anti-nitro tyrosine antibody by Western blot analysis. Blood levels of TBARS, NO, GSH, vitamins A and C, SOD and GPx were also determined. In the autistic groups, decreased concentration of protein in both hair and nail samples was observed. The SDS-PAGE analysis revealed that there was a significant decrease in both high and low sulfur proteins in the hair and nail extracts of autistic children and the Western blot analysis showed increased percentage of nitration of low sulfur proteins in autistic children when compared with normal children. Decreased levels of enzymatic and non-enzymatic antioxidants and increased concentration of TBARS and NO were also observed in the blood of autistic children. The LFA group showed more significant alteration (p<0.001) in the concentration of proteins (in hair and nail) and percentage of nitration when compared with HFA and controls. Lower protein content and higher percentage of nitration in hair and nail of autistic children correlated with their degrees of severity. Copyright © 2011 Elsevier B.V. All rights reserved.
Goldzak, M; Simon, P; Mittlmeier, T; Chaussemier, M; Chiergatti, R
2014-01-01
Nowadays, open anatomic reduction and internal fixation can be considered as a valuable treatment for displaced intra-articular fractures of the calcaneus. However, the application of a calcaneal plate via an extensile lateral approach is at risk for a substantial rate of complications including delayed healing, skin necrosis, or infection. There is some evidence that a limited exposure might contribute to a decreased soft tissue complication rate bearing in mind that most minimally invasive techniques have to accept a reduced primary stability compared with the open application of an angular stable plate. Recently, an intrafocal minimal invasive reduction technique has been established employing an intramedullary nail for fracture stabilisation and support of the subtalar joint. The aim of this study was to compare the primary biomechanical performance of the new device versus lateral angular stable plating. Biomechanical testings were performed on 14 human cadaveric feet (7 pairs). Dry calcaneal bones were fractured resulting in a Sanders type IIB fracture pattern and fixed by either a calcaneal locking plate or an intramedullary calcaneal nail. Compressive testing via the corresponding talus was employed at a constant loading velocity until failure with an universal testing machine and a specific mounting device to avoid any shear forces. Apart from the data of the load deformation diagram the relative motion of the fracture elements during loading was recorded by 8 extensometric transducers. After failure the specimens were carefully examined to check the failure patterns. The displacement of the subtalar joint fragment was substantially lower in specimens fixed with the nail. Stiffness and load to failure were significantly higher after fixation with the intramedullary nail than after application of the angular stable plate. Failure with both fixation modes generally occurred at the anterior calcaneal process fragment. The primary stability of an intramedullary nail appeared to be superior to an angular stable plate representing the present standard technique in open reconstruction of the fractured calcaneus. The results from the experimental model speak in favour of the clinical use of the intramedullary calcaneal nail. Copyright © 2013 Elsevier Ltd. All rights reserved.
Prognostic Factors for Predicting Outcomes After Intramedullary Nailing of the Tibia
Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.; Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.
2012-01-01
Background: Prediction of negative postoperative outcomes after long-bone fracture treatment may help to optimize patient care. We recently completed the Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT), a large, multicenter trial of reamed and unreamed intramedullary nailing of tibial shaft fractures in 1226 patients. Using the SPRINT data, we conducted an investigation of baseline and surgical factors to determine any associations with an increased risk of adverse events within one year of intramedullary nailing. Methods: Using multivariable logistic regression analysis, we investigated fifteen baseline and surgical factors for any associations with an increased risk of negative outcomes. Results: There was an increased risk of negative events in patients with a high-energy mechanism of injury (odds ratio [OR] = 1.57; 95% confidence interval [CI], 1.05 to 2.35), a stainless steel compared with a titanium nail (OR = 1.52; 95% CI, 1.10 to 2.13), a fracture gap (OR = 2.40; 95% CI, 1.47 to 3.94), and full weight-bearing status after surgery (OR = 1.63; 95% CI, 1.00 to 2.64). There was no increased risk with the use of nonsteroidal anti-inflammatory agents, late or early time to surgery, or smoking status. Open fractures had a higher risk of events among patients treated with reamed nailing (OR = 3.26; 95% CI, 2.01 to 5.28) but not in patients treated with unreamed nailing (OR = 1.50; 95% CI, 0.92 to 2.47). Patients with open fractures who had wound management either without any additional procedures or with delayed primary closure had a decreased risk of events compared with patients who required subsequent, more complex reconstruction (OR = 0.18 [95% CI, 0.09 to 0.35] and 0.29 [95% CI, 0.14 to 0.62], respectively). Conclusions: We identified several baseline fracture and surgical characteristics that may increase the risk of adverse events in patients with tibial shaft fractures. Surgeons should consider the predictors identified in our analysis to inform patients treated for tibial shaft fractures. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23032589
Megas, P; Kaisidis, A; Zouboulis, P; Papas, M; Panagopoulos, A; Lambiris, E
2005-01-01
We have performed a retrospective comparative study between the trochanteric gamma nail (TGN) and the proximal femoral nail (PFN). During the period 1998-2003, 97 TGN and 83 PFN were used for the treatment of pertrochanteric fractures. Most of the fractures were of the A3 type according to the AO/ASIF classification. Clinical and radiological follow-ups were available for 87 TGN and 65 PFN. The mean operative time for the TGN was shorter than that for the PFN. Intraoperative complications were noted in 17.5 % and 28.8 % for the TGN and PFN groups, respectively. Late complications occurred in 18.4 % for TGN compared to 27.6 % of the PFN. Union was achieved in 94.2 % and 89.3 % of the patients treated with the TGN and PFN, respectively. The reoperation rates were 10.3 % and 24.6 % for the TGN and the PFN, respectively. Clinical outcomes were good for both groups (65 % in the TGN, 62 % in the PFN group). Treatment of pertrochanteric fractures using the TGN and PFN implants is quite reliable. The major complication was cut-out and occurred mostly in the PFN group, while varus deformity was more frequent in the TGN group. The PFN was associated with a higher rate of reoperation and longer operative time, probably due to a more demanding technique.
Lee, Arthur T; Sundberg, Eric B; Lindsey, Derek P; Harris, Alex H S; Chou, Loretta B
2010-02-01
Tibiocalcaneal arthrodesis is an uncommon salvage procedure used for complex problems of the ankle and hindfoot. A biomechanical evaluation of the fixation constructs of this procedure has not been studied previously. The purpose of this study was to compare intramedullary nail to blade plate fixation in a deformity model in fatigue endurance testing and load to failure. Nine matched pairs of fresh frozen cadaveric legs underwent talectomy followed by fixation with a blade plate and 6.5-mm fully threaded cancellous screw or an ankle arthrodesis intramedullary nail. The specimens were loaded to 270 N at a rate of 3 Hz for a total of 250,000 cycles, followed by loading to failure. Intramedullary nail fixation demonstrated greater mean stiffness throughout the fatigue endurance testing, from cycles 10 through 250,000 (blade plate versus intramedullary nail; cycle 10, 93 +/- 34 N/mm versus 117 +/- 40 N/mm (t = 2.33, p = 0.04); cycle 100, 89 +/- 34 N/mm versus 118 +/- 42 N/mm (t = 3.16, p = 0.01); cycle 1000, 86 +/- 32 N/mm versus 120 +/- 45 N/mm (t = 3.52, p = 0.01); cycle 10,000, 83 +/- 36 N/mm versus 128 +/- 50 N/mm (t = 3.80, p = 0.01); cycle 100,000, 82 +/- 34 N/mm versus 126 +/- 52 N/mm (t = 3.70, p = 0.01); cycle 250,000, 80 +/- 31 N/mm versus 125 +/- 49 N/mm (t = 4.2, p = 0.003). There was no statistically significant difference between the intramedullary nail and blade plate fixation in cycle one or in load to failure; cycle 10, blade plate 70 +/- 38 N/mm and intramedullary nail 67 +/- 20 N/mm (t = 0.60, p = 0.56); load to failure, blade plate 808 +/- 193 N, IMN 1074 +/- 290 N) (p = 0.15). Intramedullary nail fixation was biomechanically superior to blade plate and screw fixation in a tibiocalcaneal arthrodesis construct. The ankle arthrodesis intramedullary nail provides greater stiffness for fixation in tibiocalcaneal arthrodesis, which may improve healing.
Kaiser, Martin M; Stratmann, Christine; Zachert, Gregor; Schulze-Hessing, Maaike; Gros, Nina; Eggert, Rebecca; Rapp, Marion
2014-01-08
Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice. For each of the 3 configurations of ESIN-osteosynthesis with titanium nails eight composite femoral grafts (Sawbones®) with an identical spiral fracture were used: 2C configuration (2C-shaped nails, 2 × 3.5 mm), 3CM configuration (3rd nail from medial) and 3CL configuration (3rd nail from lateral). Each group underwent biomechanical testing in 4-point bending, internal/external rotation and axial compression. 2C and 3CM configurations showed no significant differences in this spiroid type fracture model. 3CL had a significantly higher stiffness during anterior-posterior bending, internal rotation and 9° compression than 2C, and was stiffer in the lateral-medial direction than 3CM. The 3CL was less stable during p-a bending and external rotation than both the others. As biomechanical testing showed a higher stability for the 3CL configuration in two (a-p corresponding to recurvation and 9° compression to shortening) of three directions associated with the most important clinical problems, we added a 3rd nail in ESIN-osteosynthesis for femoral fractures. 11 boys and 6 girls (2.5-15 years) were treated with modified ESIN of whom 12 were '3CL'; due to the individual character of the fractures 4 patients were treated with '3CM' (third nail from medial) and as an exception 1 adolescent with 4 nails and one boy with plate osteosynthesis. No additional stabilizations or re-operations were necessary. All patients achieved full points in the Harris-Score at follow-up; no limb length discrepancy occurred. The 3CL configuration provided a significantly higher stiffness than 2C and 3CM configurations in this biomechanical model. These results were successfully transmitted into clinical practice. All children, treated by 3CL or 3CM according to the individual character of each fracture, needed no additional stabilization and had no Re-Do operations. As a consequence, at our hospital all children with femoral diaphyseal fractures with open physis are treated with this modified ESIN-technique.
Knee arthrodesis with an intramedullary nail: a retrospective study.
De Vil, Jeroen; Almqvist, Karl Fredrik; Vanheeren, Philippe; Boone, Barbara; Verdonk, René
2008-07-01
A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure was evaluated with radiographs, the SF-36 score and the Oxford 12-item knee score. The functional result of a successful arthrodesis was found to be comparable with that of a revised hinged total knee arthroplasty. Knee arthrodesis with an intramedullary nail allows weightbearing within 1 week and is accompanied by a high rate of pain relief. However, recurrence of infection is the most challenging problem.
Clinical features and nail clippings in 52 children with psoriasis.
Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina
2018-03-01
Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.
Biocompatibility of sol-gel-derived titania-silica coated intramedullary NiTi nails.
Muhonen, V; Kujala, S; Vuotikka, A; Aäritalo, V; Peltola, T; Areva, S; Närhi, T; Tuukkanen, J
2009-02-01
We investigated bone response to sol-gel-derived titania-silica coated functional intramedullary NiTi nails that applied a continuous bending force. Nails 26 mm in length, either straight or with a radius of curvature of 28 or 15 mm, were implanted in the cooled martensite form from a proximal to distal direction into the medullary cavity of the right femur in 40 Sprague-Dawley rats. Body temperature restored the austenite form, causing the curved implants to generate a bending force on the bone. The femurs were examined after 24 weeks. Bone length measurements did not reveal any bowing or shortening of the bone in the experimental groups. The results from histomorphometry demonstrated that the stronger bending force, together with sol-gel surface treatment, resulted in more bone deposition around the implant and the formation of significantly less fibrous tissue. Straight intramedullary nails, even those with a titania-silica coating, were poorly attached when compared to the implants with a curved austenite structure.
Lasing in optimized two-dimensional iron-nail-shaped rod photonic crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwon, Soon-Yong; Moon, Seul-Ki; Yang, Jin-Kyu, E-mail: jinkyuyang@kongju.ac.kr
2016-03-15
We demonstrated lasing at the Γ-point band-edge (BE) modes in optimized two-dimensional iron-nail-shaped rod photonic crystals by optical pulse pumping at room temperature. As the radius of the rod increased quadratically toward the edge of the pattern, the quality factor of the Γ-point BE mode increased up to three times, and the modal volume decreased to 56% compared with the values of the original Γ-point BE mode because of the reduction of the optical loss in the horizontal direction. Single-mode lasing from an optimized iron-nail-shaped rod array with an InGaAsP multiple quantum well embedded in the nail heads was observedmore » at a low threshold pump power of 160 μW. Real-image-based numerical simulations showed that the lasing actions originated from the optimized Γ-point BE mode and agreed well with the measurement results, including the lasing polarization, wavelength, and near-field image.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-10
... limited to, nails made of round wire and nails that are cut. Certain steel nails may be of one piece construction or constructed of two or more pieces. Certain steel nails may be produced from any type of steel... following products: Non-collated (i.e., hand-drive or bulk), two-piece steel nails having plastic or steel...
Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William
2018-04-01
To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Subclinical onychomycosis is associated with tinea pedis.
Walling, H W
2009-10-01
Onychomycosis is a common cause of nail dystrophy and may be associated with tinea pedis. The presence of dermatophyte fungi in clinically normal nails is unknown. To assess the presence of dermatophyte fungi in normal-appearing toenails and to compare the risk of subclinical dermatophytosis in patients without and with concurrent tinea pedis. This is a prospective, University-based study of adults without and with microscopically confirmed tinea pedis. Subjects with dystrophy of any toenail were excluded, as were those ever previously diagnosed as having onychomycosis and those who had used topical antifungals in the past year. A great toenail clipping obtained from each subject was submitted for periodic acid-Schiff histology. One hundred and one subjects (63 men and 38 women, mean +/- SD age 45.4 +/- 15.7 years) were included. Overall, septate hyphae (ostensibly dermatophyte) were identified in seven specimens. Of the 66 control subjects, one case (1.5%) of nail dermatophyte was identified. Of the 35 subjects with tinea pedis, six cases (17%) of nail dermatophyte were identified (P = 0.0066; odds ratio 13.4, 95% confidence interval 1.6-117). There were no significant differences in age or gender between the experimental and control groups or between the nail dermatophyte-positive and negative cohorts. Dermatophyte fungi may be isolated from normal-appearing toenails. The presence of dermatophytes in this situation is strongly associated with the presence of tinea pedis. Subclinical dermatophyte in the nail plate may serve as a reservoir for ongoing local infection.
Effect of polyethylene glycols on the trans-ungual delivery of terbinafine.
Nair, Anroop B; Chakraborty, Bireswar; Murthy, S Narasimha
2010-12-01
Topical nail drug delivery could be improved by identifying potent chemical penetration enhancers. The purpose of this study was to assess the effect of polyethylene glycols (PEGs) on the trans-ungual delivery of terbinafine. In vitro permeation studies were carried out by passive and iontophoresis (0.5 mA/cm2) processes for a period of 1 h using gel formulations containing different molecular weight PEGs (30%w/w). The release of drug from the loaded nail plates and the possible mechanisms for the enhanced delivery was studied. Passive delivery using formulation with low molecular weight PEGs (200 and 400 MW) indicated moderate enhancement in the permeation and drug load in the nail plate, compared to the control formulation. However, the effect of low molecular weight PEGs was predominant during iontophoresis process with greater amount of terbinafine being permeated (≈35 µg/cm2) and loaded into the nail plate (≈2.7 µg/mg). However, little or no effect on drug delivery was observed with high molecular weight PEGs (1000- 3350 MW) in passive and iontophoresis processes. Release of drug from the nail plates loaded by iontophoresis using low molecular weight PEG (400 MW) exhibited sustain effect which continued over a period of 72 days. The enhancement in drug permeation by low molecular weight PEGs is likely due to their ability to lead to greater water uptake and swelling of nail. This study concluded that the low molecular weight PEGs are indeed a promising trans-ungual permeation enhancer.
Sarkar, Saikat; Bandyopadhyay, Ranadeb; Mukherjee, Arindam
2013-01-01
Femoral shaft fracture is the most common major paediatric orthopaedic. For generations traction and casting was the standard treatment for all femoral shaft fractures in children. Over the past two decades the advantages of fixation and rapid mobilisation have been increasingly recognised. A prospective study was conducted in five private hospitals in the district of Bankura, West Bengal over a period of two years (April 2010 to March 2012) on 70 patients with closed shaft femur fractures between 6- 14 years age of either sex. The aim was to find out the short term complications of titanium elastic nailing in diaphyseal fracture of femur in children and compare the findings of this study with pre- existing studies in this field. In our study the most common complication was pain at nail entry site (60%). 5.71% had local inflammatory reaction due to nails. Superficial infection occurred in 2.85%. At the end of 1 year, 2.85% had limb length discripancies. Proximal migration occurred in 2.85%. 2.85% encountered acute reactive synovitis, 5.71% developed angulation of fracture site and 2.85% developed per operative breakage of nail. The treatment of paediatric shaft femur fracture has been drastically changed over the last two decades to internal fixation by elastically stable intra- medullary nail (ESIN). In our study, we encountered only a few complications most of them being minor. Most of the complications were surgical technique related and were seen at the initial phase of the learning curve.
Nail toxicity induced by cancer chemotherapy.
Gilbar, Peter; Hain, Alice; Peereboom, Veta-Marie
2009-09-01
To provide a comprehensive literature review of chemotherapy-induced nail toxicity, including clinical presentation, implicated drugs and approaches for prevention and management. A search of MEDLINE and EMBASE (1966-2008) databases was conducted using the terms (and variations of the terms) antineoplastic agents, nails, nail toxicity, onycholysis, and paronychia. Bibliographies from selected articles were reviewed for appropriate references. The retrieved literature was reviewed to include all articles relevant to the clinical presentation, diagnosis, incidence, prevention, and treatment of chemotherapy-induced nail toxicity. Nail toxicity is a relatively uncommon adverse effect linked to a number of chemotherapeutic agents. Clinical presentation varies, depending on which nail structure is affected and the severity of the insult. Nail changes may involve all or some nails. Toxicity may be asymptomatic and limited to cosmetic concerns, however, more severe effects, involving pain and discomfort can occur. Taxanes and anthracyclines are the antineoplastic drug groups most commonly implicated. It is suggested that the administration schedule may influence the incidence of nail abnormalities, for example reported cases linked to the weekly administration of paclitaxel.Before instituting chemotherapy, patients should be educated regarding potential nail toxicities and strategies for prevention implemented. Management includes appropriate nail cutting, avoiding potential irritants, topical, or oral antimicrobials, and possibly cessation or dose reduction of the offending agent. Cryotherapy, through the application of frozen gloves or socks, has been beneficial in reducing docetaxel-induced nail toxicity and may be effective for other drugs.
[A favourable outcome in yellow nail syndrome: role of respiratory physiotherapy].
Fournier, C; Just, N; Leroy, S; Wallaert, B
2003-12-01
The yellow nail syndrome is a rare condition that is easily diagnosed but the nail manifestations are poorly understood. A 51 year old patient presented with a chronic cough. The diagnosis was based on the typical appearance of the nails. The patient had bilateral basal bronchiectasis. Daily physiotherapy with bronchial drainage lead to a progressive improvement in the respiratory symptoms without recourse to antibiotics. Surprisingly the abnormalities of the nails disappeared after 2 years treatment. This observation illustrates the possibility of spontaneous resolution of severe nail abnormalities during the course of the yellow nail syndrome.
Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K
2017-01-01
Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P < 0.0001). Average time required for partial and full weight bearing in the nailing group was 4.95 weeks and 10.09 weeks respectively which was significantly less ( P < 0.0001) as compared to 6.90 weeks and 13.38 weeks in the plating group. Lesser complications in terms of implant irritation, ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.
Hand injury with a nail gun: a case report with literature review.
Boya, Hakan; Uzun, Belkan
2015-01-01
The nail gun was introduced in the late 1950s to increase the ease of driving nails, studs, bolts, or staples into various hard surfaces. The nail gun is a potentially dangerous device that is still commonly used in the construction industry. Since its introduction, an increasing number of studies have reported injuries associated with nail guns. Nail gun-related injuries-such as to the head, neck, and chest-can be devastating, and in some cases, even fatal. Extremity injuries, notably in the hand, can cause loss of function, missed work, and long-term health effects. This case report describes a nail-gun injury of the hand along with a discussion of the unique features of and treatment strategies for nail gun injuries.
Dermoscopic features of nail psoriasis treated with biologics.
Hashimoto, Yuki; Uyama, Miki; Takada, Yuko; Yoshida, Kenji; Ishiko, Akira
2017-05-01
Although psoriatic nail lesions are small, they cause considerable discomfort for patients and adversely affect quality of life. Few studies have evaluated the dermoscopic features of psoriatic nails. The aim of this study was to clarify the dermoscopic features of nail psoriasis and identify those that reflect psoriatic activity. During biologic treatment of psoriasis, six patients with psoriatic nails twice underwent dermoscopic examination, with an interval of 17-42 weeks. We used the modified Nail Psoriasis Severity Index score and Psoriasis Area and Severity Index score to identify and assess dermoscopic features. We identified 10 dermoscopic findings, of which disappearance of diffuse scaling of the nail plate, transverse step-like notches and splinter hemorrhages of the nail bed, and appearance of erythematous borders of the onycholytic area were associated with improvement in Psoriasis Area and Severity Index score. Dermoscopy can detect nail changes during psoriasis treatment and should be used to evaluate treatment success. © 2017 Japanese Dermatological Association.
Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.
2008-01-01
Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574
EPR spectroscopic investigation of psoriatic finger nails.
Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke
2013-11-01
Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Knee arthrodesis using an intramedullary nail.
Crockarell, John R; Mihalko, Marc J
2005-09-01
Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3 degrees valgus. Flexion angle averaged 3.5 degrees . Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.
Rotary self-locking intramedullary nail for long tubular bone fractures.
Huang, Zhong-lian; Yang, Hai-long; Xu, Jian-kun; Xia, Xue; Wang, Xin-jia; Song, Jian-xin; Hu, Jun
2013-10-01
Intramedullary nails had been widely used in the treatment of long-bone fractures because of less interference of fractures and center bearing biomechanical advantage. However, it had been also found many shortcomings such as broken nails, delayed healing and was modified in order to achieve better efficacy and reduce complications. The aim of the present study is to compare the efficacy of rotary self-locking intramedullary nails (RSIN) with that of interlocking intramedullary nails (IIN) in the treatment of long-bone fractures. A retrospective study investigated 129 cases with long-bone fractures (36 with femoral fracture, 81 with tibial fracture, and 12 with humeral fracture). The fractures were fixed using either an RSIN or IIN. All patients underwent followup for 12-30 months. All patients in both groups achieved a clinical fracture healing standard and the postoperative affected limb muscle strength and joint function were well restored. The RSIN group required a shorter operative time and the fracture healed faster. There was no significant difference in the hospital stay, intraoperative blood loss or postoperative complications between the two groups. RSIN is used to treat long-bone fractures. Its healing efficacy is equivalent to the IIN. Moreover, the RSIN method is simpler and causes less tissue damage than the IIN, therefore having the advantage of accelerated healing.
Iwanaga, Tomoyuki; Ushigami, Tsuyoshi; Anzawa, Kazushi; Mochizuki, Takashi
2017-08-01
Tinea unguium caused by dermatophyte species are usually treated with oral antimycotic, terbinafine (TBF). To understand the mechanisms of improvement and recalcitrance of tinea unguium by oral TBF treatment, a method of quantifying dermatophyte viability in the nail was developed, and the viability of dermatophytes was analyzed in toenail lesions of 14 patients with KOH-positive tinea unguium treated with oral TBF 125 mg/day for up to 16 weeks. Mycological tests, including KOH examination and fungal culture, and targeted quantitative real-time PCR for internal transcribed spacer (ITS) region, including rRNA, were demonstrated at the initial visit and after 8 and 16 weeks of treatment. Assays in eight patients showed that average ITS DNA amount significantly decreased, to 44% at 8 weeks and 36% at 16 weeks compared with 100% at initial visit. No significant difference was observed between at 8 and 16 weeks, despite the TBF concentration in the nail supposedly more than 10-fold higher than the minimum fungicidal concentration for dermatophytes. This finding suggests the pathogenic dermatophytes in nail lesions could survive in a dormant form, such as arthroconidia, during oral TBF treatment. Both antimycotic activity and nail growth are important factors in treatment of tinea unguium.
Weninger, Patrick; Tschabitscher, Manfred; Traxler, Hannes; Pfafl, Veronika; Hertz, Harald
2010-04-01
Although a lateral starting point for tibial nailing is recommended to avoid valgus misalignment, higher rates of intra-articular damage were described compared with a medial parapatellar approach. The aim of this anatomic study was to evaluate the fracture level allowing for a safe medial nail entry point without misalignment or dislocation of fragments. Thirty-two fresh-frozen cadaver lower extremities were used to create 1-cm osteotomies at four different levels (n = 8) from 2 cm to 8 cm below the tibial tuberosity. Nine-millimeter unreamed solid titanium tibial nails (Connex, I.T.S. Spectromed, Lassnitzhohe, Austria) were inserted from a medial parapatellar incision. Misalignment (degree) and dislocation of the distal fragment were measured in the frontal and sagittal plane. A medial parapatellar approach for tibial nail insertion mainly caused valgus and anterior bow misalignment and ventral and medial fragment displacement. Mean misalignment and fragment displacement did not exceed 0.5 degree if the osteotomy was performed 8 cm to 9 cm below the tibial tuberosity. According to the results of this study, a medial parapatellar approach can be performed without misalignment and fragment dislocation in proximal tibia fractures extending 8 cm or more below the tibial tuberosity.
Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.
Jones, D M; Marsh, J L; Nepola, J V; Jacobs, J J; Skipor, A K; Urban, R M; Gilbert, J L; Buckwalter, J A
2001-04-01
During routine follow-up of patients treated with a three-piece stainless-steel modular femoral nail, osteolysis and periosteal reaction around the modular junctions of some of the nails were noted on radiographs. The purpose of this study was to evaluate the prevalence, etiology, and clinical relevance of these radiographic findings. Forty-four femoral fractures or nonunions in forty-two patients were treated with a modular stainless-steel femoral intramedullary nail. Seventeen nails were excluded, leaving twenty-seven intramedullary nails in twenty-seven patients for this study. All patients had had a femoral diaphyseal fracture; nineteen had had an acute fracture and eight, a nonunion. These twenty-seven patients returned for radiographs, a physical examination, assessment of functional outcomes, assessment of thigh pain with a visual analog scale, determination of serum chromium levels, and nail removal if desired. A control group of sixteen patients treated with a one-piece stainless-steel femoral intramedullary nail was evaluated with use of the same outcome measures and was compared with the group treated with the modular femoral nail with regard to prevalence of thigh pain and serum chromium levels. Twelve modular femoral nails were removed according to the study protocol. The modular nail junctions were analyzed for corrosion products, and histopathologic analysis of tissue specimens from the femoral canal was performed. The twenty-seven patients were seen at a mean of twenty-one months after fracture fixation; twenty-six of the twenty-seven fractures healed. Twenty-three femora had at least one of three types of abnormalities-osteolysis, periosteal reaction, or cortical thickening--localized to one or both modular junctions. Eighteen patients had severe reactions, defined as osteolysis of > or =2 mm, cortical thickening of > or =5 mm, and/or a periosteal reaction (group 1). Nine patients had mild or no reactions (group 2). Serum chromium levels in group 1 (mean, 1.27 ng/ mL; range, 0.34 to 3.12 ng/mL) were twice as high as those in group 2 (mean, 0.53 ng/mL; range, 0.12 to 1.26 ng/mL). However, this difference did not reach significance with the numbers available. The differences in serum chromium levels between group 1 and the control group with a one-piece nail (mean, 0.26 ng/mL; range, 0.015 to 1.25 ng/mL) (p<0.01) and a control group without an implant (mean, 0.05 ng/mL; range, 0.015 to 0.25 ng/ mL) (p<0.01) were significant. The level of thigh pain recorded on the visual analog scale was also significantly different between group 1 and the control group with a one-piece implant (p = 0.03). Retrieved modular nails had signs of fretting corrosion as well as stainless-steel corrosion products adherent to the junction where the osteolysis occurred. Histologic and spectrographic analysis revealed two types of corrosion products that were consistent with stainless-steel within the peri-implant tissue and were associated with a foreign-body granulomatous response. The presence of corrosion products at the taper junctions suggests that particulate debris was a major factor in the etiology of the radiographic findings of osteolysis, periosteal reaction, and cortical thickening. Serum chromium levels were substantially elevated in the patients with a modular femoral nail, and such levels may serve as a marker of fretting corrosion of these devices.
Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails.
Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago
2017-03-13
Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails.
Knee arthrodesis as limb salvage for complex failures of total knee arthroplasty.
Kuchinad, Raul; Fourman, Mitchell S; Fragomen, Austin T; Rozbruch, S Robert
2014-11-01
Patients with multiple failures of total knee arthroplasty (TKA) are challenging limb salvage cases. Twenty one patients over the last 10 years were referred to our service for knee fusion by arthroplasty surgeons who felt they were not candidates for revision TKA. Active infection was present in 76.2% and total bone loss averaged 6.6 cm. Lengthening was performed in 7/22 patients. Total time in Ilizarov frames was 9 months, with 93.3% union. Patients treated with IM fusion nails had 100% union. Average LLD increased from 3.6 to 4.5 cm following intervention, while those with concurrent lengthening improved to 1.6 cm. Findings suggest that bone loss and the soft-tissue envelope dictate knee fusion method, and multiple techniques may be needed. A treatment algorithm is presented. Copyright © 2014 Elsevier Inc. All rights reserved.
Microscopic Views of Martian Soils and Evidence for Incipient Diagenesis
NASA Technical Reports Server (NTRS)
Goetz, W.; Madsen, M. B.; Bridges, N.; Clark, B.; Edgett, K. S.; Fisk, M.; Grotzinger, J. P.; Hviid, S. F.; Meslin, P.-Y.; Ming, D. W.;
2014-01-01
Mars landed missions returned im-ages at increasingly higher spatial resolution (Table 1). These images help to constrain the microstructure of Martian soils, i.e. the grain-by-grain association of chemistry and mineralogy with secondary properties, such as albedo, color, magnetic properties, and mor-phology (size, shape, texture). The secondary charac-teristics are controlled by mineralogical composition as well as the geo-setting (transport and weathering modes, e.g. water supply, pH, atmospheric properties, exposure to radiation, etc.). As of today this association is poorly constrained. However, it is important to un-derstand soil-forming processes on the surface of Mars. Here we analyze high-resolution images of soils re-turned by different landed missions. Eventually these images must be combined with other types of data (chemistry and mineralogy at small spatial scale) to nail down the microstructure of Martian soils.
... reaction to "poison Ivy") to nail hardener or adhesives used to attach the nail tips, or simply ... avoid mechanical cleaning under nails. One should not bandage or cover the cut nails. A drying agent ...
Kose, Nusret; Çaylak, Remzi; Pekşen, Ceren; Kiremitçi, Abdurrahman; Burukoglu, Dilek; Koparal, Savaş; Doğan, Aydın
2016-02-01
Despite improvement in operative techniques and antibiotic therapy, septic complications still occur in open fractures. We developed silver ion containing ceramic nano powder for implant coating to provide not only biocompatibility but also antibacterial activity to the orthopaedic implants. We hypothesised silver ion doped calcium phosphate based ceramic nano-powder coated titanium nails may prevents bacterial colonisation and infection in open fractures as compared with uncoated nails. 33 rabbits divided into three groups. In the first group uncoated, in the second group hydroxyapatite coated, and in the third group silver doped hydroxyapatite coated titanium nails were inserted left femurs of animals from knee regions with retrograde fashion. Before implantation of nails 50 μl solution containing 10(6)CFU/ml methicillin resistance Staphylococcus aureus (MRSA) injected intramedullary canal. Rabbits were monitored for 10 weeks. Blood was taken from rabbits before surgery and on 2nd, 6th and 10th weeks. Blood was analysed for biochemical parameters, blood count, C-reactive protein and silver levels. At the end of the 10 weeks animals were sacrificed and rods were extracted in a sterile fashion. Swab cultures were taken from intramedullary canal. Bacteria on titanium rods were counted. Liver, heart, spleen, kidney and central nervous tissues samples were taken for determining silver levels. Histopathological evaluation of bone surrounding implants was also performed. No significant difference was detected between the groups from hematologic, biochemical, and toxicological aspect. Microbiological results showed that less bacterial growth was detected with the use of silver doped ceramic coated implants compared to the other two groups (p=0.003). Accumulation of silver was not detected. No cellular inflammation was observed around the silver coated prostheses. No toxic effect of silver on bone cells was seen. Silver ion doped calcium phosphate based ceramic nano powder coating to orthopaedic implants may prevents bacterial colonisation and infection in open fractures compared with those for implants without any coating. Copyright © 2015 Elsevier Ltd. All rights reserved.
... nail is detached from the nail bed, the waterproof seal formed by the skin on the nail ... should also be noted that wearing tight-fitting shoes for a prolonged time, especially while exercising, is ...
When all you have is a dermatoscope— start looking at the nails
Haenssle, Holger A.; Blum, Andreas; Hofmann-Wellenhof, Rainer; Kreusch, Juergen; Stolz, Wilhelm; Argenziano, Giuseppe; Zalaudek, Iris; Brehmer, Franziska
2014-01-01
Pigmented and non-pigmented nail alterations are a frequent challenge for dermatologists. A profound knowledge of clinical and dermatoscopic features of nail disorders is crucial because a range of differential diagnoses and even potentially life-threatening diseases are possible underlying causes. Nail matrix melanocytes of unaffected individuals are in a dormant state, and, therefore, fingernails and toenails physiologically are non-pigmented. The formation of continuous, longitudinal pigmented streaks (longitudinal melanonychia) may either be caused by a benign activation of matrix melanocytes (e.g., as a result of trauma, inflammation, or adverse drug reactions) or by a true melanocytic proliferation (e.g., in a nevus or melanoma). In general, non-continuous nail alterations, affecting only limited parts of the nail apparatus, are most frequently of non-melanocytic origin. Important and common differential diagnoses in these cases are subungual hemorrhage or onychomycosis. In addition, foreign bodies, bacterial infections, traumatic injuries, or artificial discolorations of the nail unit may less frequently cause non-continuous nail alterations. Many systemic diseases that may also show involvement of the nails (e.g., psoriasis, atopic dermatitis, lichen planus, alopecia areata) tend to induce alterations in numerous if not all nails of the hands and feet. A similar extensive and generalized alteration of nails has been reported after treatment with a number of systemic drugs, especially antibiotics and cytostatics. Benign or malignant neoplasms that may also affect the nail unit include glomus tumor, Bowen’s disease, squamous cell carcinoma, and rare collision tumors. This review aims to assist clinicians in correctly evaluating and diagnosing nail disorders with the help of dermatoscopy. PMID:25396079
Noonan, Timothy; Pinzur, Michael; Paxinos, Odysseas; Havey, Robert; Patwardhin, Avinash
2005-04-01
Fatigue fractures of the tibia have been observed at the level of the proximal end of the nail after successful tibiocalcaneal arthrodesis with a retrograde intramedullary device. To study the effect of nail length, five matched pairs of cadaver tibiae were instrumented with strain gauges and potted in methylmethacrylate from a level 3 cm proximal to the distal medial malleolus to simulate a successful tibiocalcaneal arthrodesis. A standard length (15 cm) ankle arthrodesis nail and an identical longer device terminating in the proximal tibial metaphysis were inserted in each paired tibia using appropriate technique. The strain of the posterior cortex of the tibia was recorded under bending moments of up to 50 Nm for each intact specimen after nail insertion and after proximal locking of the nail. The nails were then exchanged between the specimens of the same pairs and the experiment was repeated to insure uniformity. The standard length locked nail increased the principal strain of the posterior cortex of the tibia at the level of the proximal screw holes 5.3 times more than the locked long nail (353 and 67 microstrains), respectively. This stress concentration was not observed when the proximal extent of the nail terminated within the proximal tibial metaphysis. A successful tibiocalcaneal arthrodesis with a standard length locked intramedullary nail creates stress concentration around the proximal screw holes that may be responsible for the fractures observed clinically. This study supports the use of a "long" retrograde locked intramedullary nail for tibiocalcaneal arthrodesis in patients with systemic or localized osteopenia.
Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails
Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago
2017-01-01
Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails. PMID:28603598
Clinical Evidence for the Relationship between Nail Configuration and Mechanical Forces
Ogawa, Rei
2014-01-01
Summary: Mechanobiology is an emerging field of science that focuses on the way physical forces and changes in cell or tissue mechanics contribute to development, physiology, and disease. As nails are always exposed to physical stimulation, mechanical forces may have a particularly pronounced effect on nail configuration and could be involved in the development of nail deformities. However, the role of mechanobiology in nail configuration and deformities has rarely been assessed. This review describes what is currently understood regarding the effect of mechanical force on nail configuration and deformities. On the basis of these observations, we hypothesize that nails have an automatic curvature function that allows them to adapt to the daily upward mechanical forces. Under normal conditions, the upward daily mechanical force and the automatic curvature force are well balanced. However, an imbalance between these 2 forces may cause nail deformation. For example, pincer nails may be caused by the absence of upward mechanical forces or a genetic propensity increase in the automatic curvature force, whereas koilonychias may occur when the upward mechanical force exceeds the automatic curvature force, thereby causing the nail to curve outward. This hypothesis is a new concept that could aid the development of innovative methods to prevent and treat nail deformities. PMID:25289309
Mückley, Thomas; Hoffmeier, Konrad; Klos, Kajetan; Petrovitch, Alexander; von Oldenburg, Geert; Hofmann, Gunther O
2008-03-01
Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Regardless of the bone model, the nails with angle-stable or compressed angle-stable locking had better initial stability and better stability following cycling than did the nails with static locking.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-05
... published in the Federal Register our preliminary notice to rescind the NSR with respect to Shanghai Colour... should be rescinded. \\1\\ Shanghai Colour Nail Co., Ltd. (aka, Shanghai Colour Nail Import & Export Co., Ltd.), and Wuxi Colour Nail Co., Ltd. (collectively ``Shanghai Colour''). \\2\\ See Certain Steel Nails...
Union rate of tibiotalocalcaneal nails with internal or external bone stimulation.
De Vries, J George; Berlet, Gregory C; Hyer, Christopher F
2012-11-01
The use of bone growth stimulation has been reported in the application of hindfoot and ankle arthrodesis. Most studies have been retrospective case series with few patients. The authors present a comparative analysis of patients undergoing tibiotalocalcaneal (TTC) arthrodesis via a retrograde intramedullary arthrodesis nail to evaluate the influence of internal versus external bone stimulation in this population. One hundred fifty-four patients were treated with retrograde intramedullary nailing. A comprehensive chart and radiographic review was performed from a database of patients who underwent TTC fusion with or without bone stimulation. Ninety-one patients with retrograde TTC nailing were treated with direct current internal bone stimulation at the time of the index procedure (internal group) and 63 were treated with combined magnetic field external bone stimulation (external group). The primary end point was fusion with potential variables evaluated for influence on fusion rates. Demographically the cohorts were similar groups in age and comorbidities. Surgical and outcome data were examined, and there were few statistically significant differences between the two groups. There was no statistically significant difference in rate of union (52.7% and 57.1%, p = .63) or rate of complications between the internal and external groups. Overall, the success rate for achieving a stable, functional limb for the groups was 81.3% (74/91 patients) and 82.5% (52/63 patients) in the internal and external groups, respectively (p = .62). The authors demonstrated there were no statistically significant differences between the union and complication rate when comparing these types of internal and external bone stimulation in this patient population. Consideration of these results may help guide physicians when considering bone stimulation as an adjunct to TTC fusions with a retrograde intramedullary nail.
Treatment of psoriatic nails with indigo naturalis oil extract: a non-controlled pilot study.
Lin, Yin-Ku; See, Lai-Chu; Chang, Ya-Ching; Huang, Yu-Huei; Chen, Jiun-Liang; Tsou, Teng-Cheng; Leu, Yann-Lii; Shen, Yu-Ming
2011-01-01
In the treatment of nail psoriasis, standardized therapeutic regimens are currently lacking. To evaluate the therapeutic efficacy of indigo naturalis oil extract in patients with nail psoriasis. Patients with nail psoriasis applied indigo naturalis oil extract on affected nails twice daily for 24 weeks. Efficacy was evaluated using the Nail Psoriasis Severity Index (NAPSI) and modified target NAPSI for the single most severely affected nail. Twenty-eight out of 32 patients completed the study. The mean NAPSI was 36.1 ± 14.7 at baseline and decreased to 14.9 ± 11.1 at week 24 while the mean modified target NAPSI was 11.7 ± 3.9 at baseline and decreased to 3.6 ± 3.2 at week 24. Indigo naturalis oil extract appeared to improve nail psoriasis. Although preliminary, these results indicate that it could provide a novel therapeutic option for nail psoriasis, a disease notoriously difficult to treat. Copyright © 2011 S. Karger AG, Basel.
Nail disorders in infants and children.
Piraccini, Bianca Maria; Starace, Michela
2014-08-01
Nail diseases in infants and children are an uncommon cause of consultation and are often difficult to diagnose and to manage. This review will cover nail diseases that are most commonly seen in clinical practice, including congenital and hereditary disorders and inflammatory, infective, and neoplastic nail diseases. The purpose of the review is to help the reader to recognize nail disorders at an early age and to manage them appropriately. Two recent large studies have reported the clinical findings of genetic disorders involving the nails, that is, pachyonychia congenita and epidermolysis bullosa. Only a few articles gave a comprehensive review of a disease, as occurred for onychomycosis, while the majority of the reports published in the recent literature involve single cases. Nail diseases in children and neonates are not easy to diagnose by nonexperts. Basic knowledge of the anatomy and biology of the nail facilitates their diagnosis as the understanding of their pathophysiology. This review gives hints at the most common nail diseases that affect infants and children.
Nail psoriasis masqueraded by secondary infection with Rhodotorula mucilaginosa.
Martini, K; Müller, H; Huemer, H P; Höpfl, R
2013-11-01
A 38-year-old man presented with whitish nail changes on all fingers as the sole symptom. The condition had developed within a few days and led to dystrophy of the proximal part of the nail plates. As microscopic examination of nail scrapings demonstrated budding hyphae and the patient working as a teacher reported frequent use of a wet sponge, antifungal therapy was initiated. Subsequent cultures and molecular typing identified Rhodotorula mucilaginosa (formerly R. rubra). This environmental yeast was repeatedly isolated despite of therapy with itraconazole. As no improvement was achieved and testing of the biological activity of the fungus revealed only marginal keratolytic activity, it was considered as a coloniser of a destructed nail matrix. Finally, a biopsy of the nail bed confirmed the diagnosis of nail psoriasis, which rapidly responded to treatment with acitretin and topical calcipotriol/betamethasone cream. Fungal growth in destructed nails masqueraded the underlying disease and may have triggered the psoriatic nail reaction. © 2013 Blackwell Verlag GmbH.
Nail tic disorders: Manifestations, pathogenesis and management.
Singal, Archana; Daulatabad, Deepashree
2017-01-01
Nail tic disorders are classic examples of overlap between the domains of dermatology and psychiatry. They are examples of body-focused repetitive behaviors in which there is an irresistible urge or impulse to perform a certain behavior. The behavior is reinforced as it results in some degree of relief and pleasure. Nail tic disorders are common, yet poorly studied and understood. The literature on nail tic disorders is relatively scarce. Common nail tics include nail biting or onychophagia, onychotillomania and the habit tic deformity. Some uncommon and rare nail tic disorders are onychoteiromania, onychotemnomania, onychodaknomania and bidet nails. Onychophagia is chronic nail biting behavior which usually starts during childhood. It is often regarded as a tension reducing measure. Onychotillomania is recurrent picking and manicuring of the fingernails and/or toenails. In severe cases, it may lead to onychoatrophy due to irreversible scarring of the nail matrix. Very often, they occur in psychologically normal children but may sometimes be associated with anxiety. In severe cases, onychotillomania may be an expression of obsessive-compulsive disorders. Management of nail tic disorders is challenging. Frequent applications of distasteful topical preparations on the nail and periungual skin can discourage patients from biting and chewing their fingernails. Habit-tic deformity can be helped by bandaging the digit daily with permeable adhesive tape. Fluoxetine in high doses can be helpful in interrupting these compulsive disorders in adults. For a complete diagnosis and accurate management, it is imperative to assess the patient's mental health and simultaneously treat the underlying psychiatric comorbidity, if any.
Review of end grain nail withdrawal research
Douglas R. Rammer; Samuel L. Zelinka
2004-01-01
This study reviewed the literature on static and impact withdrawal of nails driven into the end grain of wood members. From this, an empirical relationship was created relating the specific gravity of the wood, the diameter of the nail, and the depth of penetration of the nail to the static withdrawal capacity of nails driven into the wood and withdrawn immediately....
Investigation of Human Nail Microstructure with Ultrasound
NASA Astrophysics Data System (ADS)
Maeva, A. R.; Bakulin, E. Y.; Denisova, L. A.; Maev, R. Gr.
Investigation of a human fingernail and the extraction of the data on its microstructure and elastic properties is important in three main aspects. First of all, various diseases of the nail can be differentiated more precisely; second of all, it is possible to non-invasively track during time the effects of a cosmetic product upon the nail; third of all, because various processes in the organism have a strong influence upon the nail plate growth, the monitoring of the nail morphology and its mechanical properties may be used as additional information for the diagnosis of a number of medical disorders, such as systemic sclerosis, psoriasis, chronic hand eczema, anemia etc. The aim of the present study was to carry out a detailed ultrasound investigation in the high-frequency range (25-50 MHz) of a human nail including micro-anatomical structure imaging and ultrasound velocity evaluation, using B-scans obtained with a scanning acoustic microscope. On the images, exact topology of the nail, nail matrix and the underlying bone have been revealed. Additionally, a certain type of inclined internal layering along the nails of some individuals has been found, which was not reported in previous ultrasonic studies of the nail.
Jumbo Cutter for Removal of A Bent Femoral Interlocking Nail: A Cost Effective Method
Dhanda, Manjeet Singh; Sharma, Sansar C; Ali, Nadeem; Bhat, Abedullah
2015-01-01
Closed diaphyseal femoral shaft fractures can be treated with multiple surgical options. It is more challenging to remove a bent nail than a broken one because it is difficult to retrieve the bent nail through the intramedullary canal. Various authors have published their techniques for removal of bent femoral interlocking nail. This article describes a simple technique using Jumbo cutter for sectioning and removal of bent interlocking nail. This technique will help orthopaedic surgeons to remove bent nail without using any specialised metal cutting instruments. PMID:26266173
The nail and hair in forensic science.
Daniel, C Ralph; Piraccini, Bianca Maria; Tosti, Antonella
2004-02-01
Drugs, chemicals, and biological substances accumulate and are stored in hair and nails where they can be detected and measured. Advantages of analyzing hair and nail samples also include their easy and non-invasive collection, the small sample size required for analysis, and their easy storage at room temperature. We report 3 examples of heavy metal poisoning diagnosed because of the hair or nail symptoms. Drugs and toxins that can be detected in hair and nails are reviewed and the application of hair/nail analysis in general and in forensic medicine is discussed.
Misiak, Piotr; Terlecki, Artur; Rzepkowska-Misiak, Beata; Wcisło, Szymon; Brocki, Marian
2014-02-01
Ingrowing nail also known as onychocryptosis is a common health problem. This disease mostly affects young people, often carrying a considerable amount of socio-economic implications. It's foot problem that usually manifests as inflammation of tissue along the side of a toenail. The aim of the study was to asses and to compare effectiveness of electrocautery and phenol application in partial matrixectomy after partial nail extraction in the treatment of ingrown toenails. The group of 60 patients with ingrowing toenail which was randomized into two groups underwent partial matrixectomy in surgical outpatient clinic between 2009-2013. This group of patients was under surgical observation for 100 days in outpatient clinic. In all operated patients we obtained surgical success however we had 13 recurrences during the follow up period, 5 in the phenolization group and 8 in the electrocoagulation group. There was statistically significant difference between these two techniques, which indicated that matrix phenolization is connected with shortened healing time vs the matrix electrocoagulation.
Khallaf, Fathy G; Kehinde, Elijah O
2015-12-01
The aim of study was to test, for the presence of osteoblasts in the reaming debris of intramedullary nailing of femoral and tibial fracture in patients with and without severe head injury. Two groups of patients were studied. Group A (n = 32) had long bone fractures in addition to having head injuries. Group B (n = 35) had only long bone fractures. The fractures in the 2 groups of patients was treated by inter medullary nailing. Osteoblasts in the debris of the inter medullary nailing was compared between the 2 groups of patients. The results demonstrated that histopathological specimens from reaming debris of fractured femur and tibia in patients with head injury showed osteoblasts in (82.9%) and in (27.5%) of patients with isolated long bone fractures (p < 0.001). Healing indicators in diaphyseal fractures and concomitant head injury confirm fast and adequate healing in these patients and the presence of plenty of osteoblasts in their reaming debris may reflect a proof of accelerated fracture healing environment.
Gavaskar, Ashok S; Chowdary, Naveen
2009-12-01
To review 7 patients with advanced osteoarticular tuberculous arthritis of the ankle who underwent arthrodesis using a supracondylar femoral nail. All patients showed gross destruction of the articular cartilage of the tibiotalar joint with severe periarticular rarefaction on radiographs. Their pre- and one-year post-operative Foot and Ankle Outcome Scores (FAOS) were compared. All patients underwent joint debridement, complete synovial excision, and arthrodesis using a supracondylar femoral nail, followed by multidrug chemotherapy for 12 months (isoniazid, rifampicin, pyrazinamide, and ethambutol for 3 months, and isoniazid and rifampicin for 9 months). All patients achieved fusion in a mean of 13 weeks and regained their preoperative level of independence. No patient had a relapse, major complications, or hardware failure. At postoperative year one, the mean FAOS for pain improved to 85 from 26, whereas the mean FAOS for quality of life improved to 60 from 5. Tibiotalocalcaneal arthrodesis using a supracondylar femoral nail, combined with debridement and multidrug therapy, enabled a reliable one-stage solution for advanced osteoarticular tuberculosis and early return to function.
Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Wei; Ho, Yi-Hung; Peng, Yao-Te; Chang, Chih-Han; Li, Chun-Ting
2017-03-01
This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.
(Meth)Acrylate Occupational Contact Dermatitis in Nail Salon Workers: A Case Series.
DeKoven, Samuel; DeKoven, Joel; Holness, D Linn
Recently, many cases of acrylate-associated allergic contact dermatitis have appeared among nail salon workers. Common acrylate-containing products in nail salons include traditional nail polish, ultraviolet-cured shellac nail polish, ultraviolet-cured gel nails, and press-on acrylic nails. Nail salon technicians seen in the occupational medicine clinic in 2015 and 2016 were identified, and their patch test results and clinical features were summarized. Patch testing was done with the Chemotechnique (Meth)Acrylate nail series, and either the North American Standard series or the North American Contact Dermatitis Group screening series. Six patients were identified, all women, ages 38 to 58. Common presentations included erythematous dermatitis of the dorsa of the hands, palms, and forearms and fissures on the fingertips. Less common sites of eruptions included the periorbital region, cheeks, posterior ears, neck, sacral area, lateral thighs, and dorsa of the feet. All patients reacted to hydroxyethyl methacrylate, and 5 patients reacted to ethyl acrylate. Each patient also reacted to (meth)acrylates that are not found on either standard series, including ethyleneglycol dimethacrylate, 2-hydroxypropyl methacrylate, and 2-hydroxyethyl acrylate. The authors report 6 cases of allergic contact dermatitis to acrylates in nail technicians seen over the past year, representing a new trend in their clinic. These cases are reflective of a growing trend of nail technicians with allergic contact dermatitis associated with occupational (meth)acrylate exposure. Efforts to improve prevention are needed.
Jeelani, Shazia; Ahmed, Qazi Masood; Lanker, Audil Mohmad; Hassan, Iffat; Jeelani, Nasir; Fazili, Tawheeda
2015-01-01
Onychomycosis is fungal infection of one or more of the nail units. However, because fungi cause only about half of all nail dystrophies, the use of appropriate diagnostic techniques is important to ensure correct diagnosis and treatment. Aim of the present study was to compare direct microscopy, culture and HPE-PAS for diagnosis of onychomycosis by evaluating their sensitivity and various other relevant statistical parameters. A prospective, hospital-based, cross-sectional study was conducted on 216 patients with a high degree of clinical suspicion of onychomycosis. Nail specimens were evaluated using three diagnostic methods, i.e. direct microscopy using 20% Potassium hydroxide (KOH) & 40% Di-methyl-suphoxide (DMSO), culture and histopathological examination using PAS stain (HPE-PAS). Of 216 patients direct microscopy was positive in 138 (63.9%), culture in 147 (68%) and HPE-PAS in 164 patients (76%). One hundred and seventy-nine patients fitted into the criteria set for confirmed diagnosis of onychomycosis. Using this as a denominator; direct microscopy, culture and HPE-PAS had sensitivities of 77.1%, 70% and 91.6% respectively. Also, HPE-PAS showed the highest sensitivity of 94.7% in 19 cases with prediagnostic antimycotic treatment compared to direct microscopy (42.1%) or culture (57.9%). HPE-PAS shows high sensitivity for diagnosis of onychomycosis and can be considered as a gold standard in the diagnosis of onychomycosis. © 2014 Blackwell Verlag GmbH.
Scotté, Florian; Banu, Eugeniu; Medioni, Jacques; Levy, Eric; Ebenezer, Christelle; Marsan, Sandrine; Banu, Adela; Tourani, Jean Marc; Andrieu, Jean-Marie; Oudard, Stéphane
2008-04-01
Onycholysis occurs in approximately 30% of patients treated with docetaxel. The efficacy and safety of an Elasto-Gel frozen sock (FS) was investigated for the prevention of docetaxel-induced nail and skin toxicity of the feet. Patients receiving docetaxel at a dose of 70 to 100 mg/m(2) every 3 weeks were eligible for this matched case-control study. Each patient wore an FS for 90 minutes on the right foot. The unprotected left foot acted as control. Nail and skin toxicities were assessed using National Cancer Institute Common Toxicity Criteria (version 3) and compared using a 2-sample Wilcoxon matched-pairs rank test adjusted for tied values. Fifty consecutive patients were included between April 2005 and January 2007. Nail toxicity was significantly lower in the FS-protected foot compared with the control foot (grade 0: 100% versus 79%; and grade 1 and 2: 0% versus 21%, respectively) (P= .002). Skin toxicity was grade 0: 98% versus 94%; and grade 1 and 2: 2% versus 6% in the FS-protected and the control feet, respectively. The median times until toxicity occurrence were not found to differ significantly between the groups. One patient experienced discomfort because of cold intolerance. Cold therapy using FS significantly reduced the incidence of docetaxel-induced foot nail toxicity, as previously demonstrated using frozen gloves for the hands.
Low-Velocity Nail-Gun Injuries to the Interventricular Septum: Report of Two Cases, One in a Child.
Michalsen, Kara L; Iguidbashian, John P; Kyser, James P; Long, William B
2015-08-01
Nail-gun injury to the heart is rare. Nail-gun injury to the interventricular septum is rarer: we could find only 5 reported cases, and none involving a child. We report 2 additional cases, in which nails penetrated the interventricular septum without causing acute pericardial tamponade, heart block, or shunt across the septum. Transesophageal echocardiography provides a dynamic way to evaluate the patient preoperatively, intraoperatively, and postoperatively. In the cases reported here, both the adult with multiple interventricular nails and the child with a single nail underwent foreign-object removal via median sternotomy. The child needed cardiopulmonary bypass for removal of the nail. There were no short-term or long-term sequelae from these interventricular septal injuries.
Zhao, Yanmin; Wang, Jiasheng; Luo, Yi; Shi, Jimin; Zheng, Weiyan; Tan, Yamin; Cai, Zhen; Huang, He
2017-08-01
The relative merits of reduced intensity hematopoietic stem cell transplantation (RIST) for chronic myeloid leukemia (CML) in the first chronic phase (CP) in imatinib era have not been evaluated. The study was designed to compare the outcomes of combination therapy of RIST plus imatinib (RIST + IM) vs. imatinib (IM) alone for young patients with early CP (ECP) and late CP (LCP). Of the patients, 130 were non-randomly assigned to treatment with IM alone (n = 88) or RIST + IM (n = 42). The 10-year overall survival (OS) and event-free survival (EFS) were comparable between RIST + IM and IM groups. LCP, high Sokal score, and no complete cytogenetic response at 3 months were adverse prognostic factors for survival, but only the time from diagnosis to IM was an independent predictor after multivariate analysis. For ECP, IM was similar to RIST + IM, with 10-year EFS rates of 77.2 vs. 81.6% (p = 0.876) and OS rates of 93.8 vs. 87.9% (p = 0.102), respectively. For LCP, both treatments resulted in similar survival, but more patients in the imatinib group experienced events (10-year EFS 40.8 vs. 66.7%, p = 0.047). The patients with higher EBMT risk scores had an inferior survival than those with lower scores (69.2 vs. 92.9%, p = 0.04). We concluded that RIST + IM was comparable to IM in terms of OS and EFS. However, RIST + IM was more affordable than IM alone in a 10-year scale. Thus, RIST + IM could be considered as an alternative treatment option, especially when the patients have low EBMT risk scores and demand a definite cure for CML.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-23
...) Maanshan Longer Nail Product Co., Ltd. (24) Nanjing Dayu Pneumatic Gun Nails Co., Ltd. (25) Qingdao.... (71) Tianjin Shishun Metallic Products Co., Ltd. (72) Tianjin Xiantong Fucheng Gun Nail Manufacture Co...
Soil nailing of a bridge fill embankment : construction report.
DOT National Transportation Integrated Search
1991-08-01
Soil nailing as an alternative lateral earth support method has recently been introduced in Oregon to build the first permanent Soil-Nailed Wall on the State's Highway System. : The soil nailing technique was used for an underpass widening to provide...
Nail Scabies: An Unusual Presentation Often Overlooked and Mistreated.
Tempark, Therdpong; Lekwuttikarn, Ramrada; Chatproedprai, Susheera; Wananukul, Siriwan
2017-04-01
Nail scabies is an interesting clinical presentation of scabies. Although it is usually found concomitant with characteristic dermatologic manifestations, it may present as an isolated finding in the immunocompromised host. This condition is commonly mistaken with other diseases such as nail dystrophy, nail psoriasis and onychomycosis. We report two cases of unusual nail presentations that provide clues to diagnosis. Also, literature on unusual nail and dermatologic presentations was reviewed to recognize dermatologist consideration for appropriate treatment options. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Research on the reasonable pile spacing of micro pile composite soil nailing
NASA Astrophysics Data System (ADS)
Liu, Jun yan; Liu, Yan; Song, Xiang hua
2017-08-01
Through the numerical simulation software FLAC3D, study on the synergetic effect of micro pile composite soil nailing will be studied. By adjusting the micro pile spacing and analysing the displacement field and stress field of soil, we can find that supporting effect of the soil nail hasn’t work yet when the micro pile spacing is 2D. The soil arching between piles has been formed in the pile spacing 4D ∼ 6D. The composite effect of micro pile and soil nailing will be the best and the soil arch behind piles will be firstly formed in 6D, the horizontal saddle soil arch will be formed between the nails. The nail head coincidence pressure area and micro pile pressure area are overlapping to maintain stability in the soil between piles. When the micro pile spacing is 9D, the arch behind piles will be failure, the soil flows around, but the saddle arch between the nails into circular arch, the supporting effect of the soil nailing is enhanced. When the micro pile spacing is 12D, the arch of the nails becomes smaller, sliding surface appears primitively. Based on the conclusions above, it is suggested that the micro pile spacing between 2D ∼ 6D is suitable for the micro pile and soil nailing composite support. The conclusion can provide theoretical basis for the design and construction of micro pile composite soil nailing.
Metikala, Sreenivasulu; Mohammed, Riazuddin
2011-07-01
Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.
Bakirci Ureyen, Sibel; Kara, Rabia Oztas; Erturk, Zeynep; Yaldiz, Mahizer
2018-05-02
The objective of this study is to evaluate the link between nail fold vessel resistive index (NVRI) measured by ultrasound (US) and capillary loops diameters measured using nailfold videocapillarascopy (NVC), and to assess the morphological appearance of the nail bed in patients with psoriatic nail disease (PND) as compared with healthy controls (HCs). This study was conducted in patients with PND and HCs. General demographic data were collected and clinical assessments were performed for all subjects. The nail plate thickness (NPT) was measured on gray scale using US. The NVRI was measured using color Doppler (CD) US. The measurements of the apical, arterial, venous limb diameters and morpho-structural changes (tortuous, cross-linked capillaries) were assessed using NVC. Thirty-four patients with PND and 15 HCs were enrolled in this study. The two groups were matched for age and body mass index (BMI). Patients with PND had higher NPT and NVRI in comparison with HCs [(20 (17-23) vs 14 (14-15), p<0.001), (0.55 (0.51-0.61) vs 0.43 (0.38-0.49), p<0.001), respectively]. A higher proportion of patients with PND had tortuous capillaries than HCs (62% and 20% respectively, p=0.005). The mean NVRI was higher in patients with PND who had tortuous capillaries than patients who did not have tortuous capillaries (0.58 (0.7) and 0.52 (0.09), respectively p=0.033). Microvascular changes can be detected easily using non-invasive methods such as US and NVC. These methods can provide an objective data to better assess PND.
Zhao, G; Liu, H N; Li, N; He, L; Wu, X B
2016-10-11
Objective: To evaluate the mid-term clinical efficacy of plate and intramedullary nail for humeral shaft fracture. Methods: In this retrospective study a total of 122 patients with humeral shaft fracture were divided into 2 groups according to surgery type from May 2010 to July 2012. There were 63 patients in plate group and 59 patients in intramedullary nail group. The factors related to the operation for each group were compared respectively. The clinical outcome was evaluated by the Neer scores, Myao scores and EuroQol 5 dimensions scores (EQ-5D). All the patients were followed up periodically in the next 3 years. Results: There were no significant differences between the two groups on hospital stay and time of returning to work ( P >0.05). While the operation time, amount of intraoperative blood loss and complication rate were less in intramedullary nail group. The mean follow-up duration was (41.2±4.2) months in plate group and (42.1±4.7) months in intramedullary nail group respectively. At the last follow-up the postoperative Neer scores, Myao scores and EQ-5D scores showed no significant differences between the 2 groups[Neer: (93.8±6.1) vs(92.1±4.2); Myao: (94.9±2.9) vs(96.2±1.5), P >0.05]. There were no cases complicated with nonunion, delayed union, infection and deformity during the follow-up period. Conclusions: The mid-term outcome of open reduction and internal fixation with plate and close reduction with intramedullary nail for humeral shaft fracture is satisfactory. Although both surgeries are safe and effective, they also have some defaults. The doctors should choose the right surgery carefully according to the actual situation of the patients.
Assessing indoor air quality in New York City nail salons.
Pavilonis, Brian; Roelofs, Cora; Blair, Carly
2018-05-01
Nail salons are an important business and employment sector for recent immigrants offering popular services to a diverse range of customers across the United States. However, due to the nature of nail products and services, salon air can be burdened with a mix of low levels of hazardous airborne contaminants. Surveys of nail technicians have commonly found increased work-related symptoms, such as headaches and respiratory irritation, that are consistent with indoor air quality problems. In an effort to improve indoor air quality in nail salons, the state of New York recently promulgated regulations to require increased outdoor air and "source capture" of contaminants. Existing indoor air quality in New York State salons is unknown. In advance of the full implementation of the rules by 2021, we sought to establish reliable and usable baseline indoor air quality metrics to determine the feasibility and effectiveness of the requirement. In this pilot study, we measured total volatile organic compounds (TVOC) and carbon dioxide (CO 2 ) concentrations in 10 nail salons located in New York City to assess temporal and spatial trends. Within salon contaminant variation was generally minimal, indicating a well-mixed room and similar general exposure despite the task being performed. TVOC and CO 2 concentrations were strongly positively correlated (ρ = 0.81; p < 0.01) suggesting that CO 2 measurements could potentially be used to provide an initial determination of acceptable indoor air quality for the purposes of compliance with the standard. An almost tenfold increase in TVOC concentration was observed when the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) target CO 2 concentration of 850 ppm was exceeded compared to when this target was met.
Takei-Masuda, Naomi; Kubota, Natsuki; Takahata, Sho; Ohyama, Makoto; Kaneda, Kaori; Iida, Maiko; Maebashi, Kazunori
2015-01-01
Fungal nail infection (onychomycosis) is a prevalent disease in many areas of the world, with a high incidence approaching 23%. Available antifungals to treat the disease suffer from a number of disadvantages, necessitating the discovery of new efficacious and safe antifungals. Here, we evaluate the in vitro antifungal activity and nail penetration ability of ME1111, a novel antifungal agent, along with comparator drugs, including ciclopirox, amorolfine, terbinafine, and itraconazole. ME1111 showed potent antifungal activity against Trichophyton rubrum and Trichophyton mentagrophytes (the major etiologic agents of onychomycosis) strains isolated in Japan and reference fungal strains with an MIC range of 0.12 to 0.5 mg/liter and an MIC50 and MIC90 of 0.5 mg/liter for both. Importantly, none of the tested isolates showed an elevated ME1111 MIC. Moreover, the antifungal activity of ME1111 was minimally affected by 5% wool keratin powder in comparison to the other antifungals tested. The ME1111 solution was able to penetrate human nails and inhibit fungal growth in a dose-dependent manner according to the TurChub assay. In contrast, 8% ciclopirox and 5% amorolfine nail lacquers showed no activity under the same conditions. ME1111 demonstrated approximately 60-fold-greater selectivity in inhibition of Trichophyton spp. than of human cell lines. Our findings demonstrate that ME1111 possesses potent antidermatophyte activity, maintains this activity in the presence of keratin, and possesses excellent human nail permeability. These results suggest that ME1111 is a promising topical medication for the treatment of onychomycosis and therefore warrants further clinical evaluation. PMID:26643333
Miltefosine is effective against Candida albicans and Fusarium oxysporum nail biofilms in vitro.
Machado Vila, Taissa Vieira; Sousa Quintanilha, Natália; Rozental, Sonia
2015-11-01
Onychomycosis is a fungal nail infection that represents ∼50 % of all nail disease cases worldwide. Clinical treatment with standard antifungals frequently requires long-term systemic therapy to avoid chronic disease. Onychomycosis caused by non-dermatophyte moulds, such as Fusarium spp., and yeasts, such as Candida spp., is particularly difficult to treat, possibly due to the formation of drug-resistant fungal biofilms on affected areas. Here, we show that the alkylphospholipid miltefosine, used clinically against leishmaniasis and cutaneous breast metastases, has potent activity against biofilms of Fusarium oxysporum and Candida albicans formed on human nail fragments in vitro. Miltefosine activity was compared with that of commercially available antifungals in the treatment of biofilms at two distinct developmental phases: formation and maturation (pre-formed biofilms). Drug activity towards biofilms formed on nail fragments and on microplate surfaces (microdilution assays) was evaluated using XTT [2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide] assays, and drug effects on fingernail biofilms were analysed by scanning electron microscopy (SEM). For F. oxysporum, miltefosine at 8 μg ml- 1 inhibited biofilm formation by 93%, whilst 256 μg ml- 1 reduced the metabolic activity of pre-formed nail biofilms by 93%. Treatment with miltefosine at 1000 μg ml- 1 inhibited biofilm formation by 89% and reduced the metabolic activity of pre-formed C. albicans biofilms by 99%. SEM analyses of biofilms formed on fingernail fragments showed a clear reduction in biofilm biomass after miltefosine treatment, in agreement with XTT results. Our results show that miltefosine has potential as a therapeutic agent against onychomycosis and should be considered for in vivo efficacy studies, especially in topical formulations for refractory disease treatment.
Retained portion of latex glove during femoral nailing. Case report.
Sadat-Ali, M; Marwah, S; al-Habdan, I
1996-11-01
A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.
Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U
2014-12-01
Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and radiologically re-examined on average 19.3 (7-31) months postoperatively. No postoperative bleeding, wound healing disorders and infections. In all patients there was a loading stable consolidation of the fracture in the correct femoral axis, length and rotation with no evidence for radiological signs of loosening of the prosthesis or dislocation of the nails. In one case there was loosening of the prosthesis which had obviously occurred during the operative procedure. After consolidation of the fracture it was necessary to exchange the prosthesis for a long shafted prosthesis. A comparable situation to the preoperative degree of mobility was found in 12 out of the 20 patients, a moderate deterioration in 5 patients, a substantial residual impairment in 2 patients and an improvement of the situation in 1 patient.
Bristow, Ivan; Baran, Robert; Score, Michelle
2016-08-01
Onychomycosis continues to be a common and intractable problem in adults, often responding poorly to topical treatment due to limited drug penetration of the nail plate. Improving penetration has been attempted previously by chemical and physical means with some success. The authors present three cases of toenail onychomycosis treated topical terbinafine 1% solution using controlled micro-penetration of the nail using a novel intelligent nail drill system which is able to drill nail plate without penetrating the delicate nail bed beneath. The cases illustrate how the device has been successfully employed to deliver the anti-fungal drug directly and rapidly to the site of infection with minimal side effects or complications, whilst maintaining the nail integrity.
J Drugs Dermatol. 2016;15(8):974-978.
Control of the micromovements of a composite-material nail design: A finite element analysis.
Ben-Or, Mor; Shavit, Ronen; Ben-Tov, Tomer; Salai, Moshe; Steinberg, Ely L
2016-02-01
Intramedullary nail fixation is the most accepted modality for stabilizing long bone midshaft fractures. The commercially used nails are fabricated from Stainless Steel or Titanium. Composite-materials (CM) mainly carbon-fiber reinforced polymers (CFRP) have been gaining more interest and popularity due to their properties, such as modulus of elasticity close to that of bone, increased fatigue strength, and radio-opacity to irradiation that permits a better visualization of the healing process. The use of CFRP instead of metals allows better control of different directional movements along a fracture site. The purpose of this analysis was to design a CM intramedullary nail to enable micromovements as depicted on a finite element analysis method. We designed a three-dimentional femoral nail model. Three CFRP with different laminates arrangements, were included in the analysis. The finite element analysis involved applying vertical and horizontal loads on each of the designed and tested nails. The nails permitted a transverse micromovement of 0.75mm for the 45° lay-up and 1.5mm for the 90° lay-up for the CM, 1.38mm for the Titanium and 0.74mm for the Stainless Steel nails. The recorded axial movements were 0.53mm for the 45° lay-up, 0.87mm for the 90° lay-up, 0.46mm for the unsymmetrical lay-up CM, 0.046 for the Titanium and 0.02 for the Stainless Steel nails. Overall, the simulations showed that nail transverse micromovements can be reduced by using 45° carbon fiber orientations. Similar results were observed with each metal nails. We found that nail micromovements can be controlled by changing the directional stiffness using different lay-up orientations. These results can be useful for predicting nail micromovements under specified loading conditions which are crucial for stimulating callus formation in the early stages of healing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Effects of nail polish on microbial growth of fingernails. Dispelling sacred cows.
Baumgardner, C A; Maragos, C S; Walz, J; Larson, E
1993-07-01
Nail polish worn on short, healthy nails does not appear to be associated with increased microbial counts on the fingernails. Additional studies to examine the effect of wearing nail polish on other aspects of hand hygiene may be warranted, however.
Treatment of Nail Psoriasis: Common Concepts and New Trends
Oram, Yasemin; Akkaya, A. Deniz
2013-01-01
The lifetime incidence of nail involvement in psoriatic patients is estimated to be 80–90%, and the nails can be affected in 10% to 55% of psoriatic patients. Psoriasis may also solely involve the nails, without any other skin findings, in which the treatment can be more challenging. Nail psoriasis may lead to considerable impairment in quality of life due to aesthetic concerns and more importantly limitations in daily activities resulting from the associated pain, which may be overlooked by the physicians. Several topical and systemic treatment modalities, as well as radiation and light systems, have been used in the treatment of nail psoriasis. In the last decade, the introduction of biologic agents and the utilization of laser systems have brought a new insight into the treatment of nail psoriasis. This paper focuses on the recent advances, as well as the conventional methods, in treating nail psoriasis in adults and children, in reference to an extensive literature search. PMID:23762032
Edwards, Scott G; Argintar, Evan; Lamb, Joshua
2011-06-01
Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.
Slofstra, Christien; Nauta, Maaike H.; Holmes, Emily A.; Bockting, Claudi L. H.
2016-01-01
Background Imagery rescripting (ImRs) is a process by which aversive autobiographical memories are rendered less unpleasant or emotional. ImRs is thought only to be effective if a change in the meaning-relevant (semantic) content of the mental image is produced, according to a cognitive hypothesis of ImRs. We propose an additional hypothesis: that ImRs can also be effective by the manipulation of perceptual features of the memory, without explicitly targeting meaning-relevant content. Methods In two experiments using a within-subjects design (both N = 48, community samples), both Conceptual-ImRs—focusing on changing meaning-relevant content—and Perceptual-ImRs—focusing on changing perceptual features—were compared to Recall-only of aversive autobiographical image-based memories. An active control condition, Recall + Attentional Breathing (Recall+AB) was added in the first experiment. In the second experiment, a Positive-ImRs condition was added—changing the aversive image into a positive image that was unrelated to the aversive autobiographical memory. Effects on the aversive memory’s unpleasantness, vividness and emotionality were investigated. Results In Experiment 1, compared to Recall-only, both Conceptual-ImRs and Perceptual-ImRs led to greater decreases in unpleasantness, and Perceptual-ImRs led to greater decreases in emotionality of memories. In Experiment 2, the effects on unpleasantness were not replicated, and both Conceptual-ImRs and Perceptual-ImRs led to greater decreases in emotionality, compared to Recall-only, as did Positive-ImRs. There were no effects on vividness, and the ImRs conditions did not differ significantly from Recall+AB. Conclusions Results suggest that, in addition to traditional forms of ImRs, targeting the meaning-relevant content of an image during ImRs, relatively simple techniques focusing on perceptual aspects or positive imagery might also yield benefits. Findings require replication and extension to clinical samples. PMID:27486966
Intramedullary nailing of humeral shaft fractures.
Pickering, Robert M; Crenshaw, Andrew H; Zinar, Daniel M
2002-01-01
The development of interlocking humeral nail systems has greatly broadened the indications for nailing of humeral shaft fracture. Rotational control is better than with earlier nail systems, and most nails have an oblong distal hole that allows axial loading of the fracture site with muscle contraction. When nailing is done with closed technique, loss of the fracture hematoma and periosteal stripping are avoided. Even when open reduction is required, periosteal stripping can be kept to a minimum. Surgical wounds are smaller, even when open reduction is necessary, and when closed nailing is done, bone grafting is unnecessary. Intramedullary nails are ideal for segmental fractures, pathologic fractures, and fractures in osteopenic bone. Because the arm usually is not a weight-bearing extremity, hardware failure is rare and union rates are equivalent to those of compression plate and screw fixation. Compression plates and external fixation certainly have their place for some fracture patterns and for severe wounds that are unsuitable for intramedullary nailing. The surgeon should be well versed in all three techniques and should be able to rapidly choose among these, depending upon the fracture pattern, skin wound, associated injuries, and overall condition of the patient.
Creep behavior of soil nail walls in high plasticity index (PI) soils : technical report.
DOT National Transportation Integrated Search
2017-04-01
An aspect of particular concern in the Geotechnical Engineering Circular No. 7: Soil Nail Walls (i.e., the soil : nail wall manual and construction guidelines) is the creep behavior of soil nail systems in high-plasticity : clays. This research proje...
Knee fusion--a new technique using an old Belgian surgical approach and a new intramedullary nail.
Alt, V; Seligson, D
2001-02-01
Knee arthrodesis is a useful procedure in difficult cases such as failed total knee arthroplasty, severe articular trauma, bone tumors, and infected knee joints. The most common techniques for knee fusion include external fixation and intramedullary nailing. Küntscher's nail is driven antegrade from the intertrochanteric region into the knee. We describe a new technique for knee arthrodesis using a new intramedullary nail and an old Belgian surgical approach to the knee joint published by Lambotte in 1913. This approach provides excellent exposure for the implantation of the nail by osteotomizing the patella vertically. The nail is implanted using HeyGroves method, whereby the nail is inserted retrograde into the femur and pulled distally anterograde into the tibia. We now use this technique as our standard procedure for knee fusion.
Clinical and biochemical characteristics of polycystic ovary syndrome in Korean women.
Chae, Soo Jin; Kim, Jin Ju; Choi, Young Min; Hwang, Kyu Ri; Jee, Byung Chul; Ku, Seung Yup; Suh, Chang Suk; Kim, Seok Hyun; Kim, Jung Gu; Moon, Shin Yong
2008-08-01
We investigated the differences in anthropometrical, hormonal and insulin resistance parameters according to the subtype of polycystic ovary syndrome (PCOS) in Korean women. We recruited 166 women with PCOS and retrospectively recruited 277 controls. PCOS was diagnosed by irregular menstruation (IM), polycystic ovary (PCO) and hyperandrogenism (HA). Subjects were divided into four subgroups: the IM/HA/PCO group (n = 87, 52.4%), the IM/PCO group (n = 52, 31.3%), the IM/HA group (n = 23, 13.9%) and the HA/PCO group (n = 4, 2.4%). Clinical and biochemical variables were compared among the PCOS subgroups. The IM/HA/PCO and IM/HA groups showed higher body mass index (P < 0.001) and waist-to-hip ratio (P < 0.001) than the IM/PCO group. The IM/HA group had higher triglyceride levels than the other groups (P < 0.001). Higher fasting insulin (P < 0.001) and postprandial 2 h insulin (P < 0.01) were noted in the IM/HA/PCO group and the IM/HA group, compared with the IM/PCO group. Women with PCOS showed lower sex hormone-binding globulin (P < 0.001) and higher systolic blood pressure (BP) (P = 0.004), diastolic BP (P = 0.001), fasting insulin (P < 0.001), postprandial 2 h insulin (P < 0.001), homeostatic model for insulin resistance (P < 0.001) and clinical and biochemical parameters of metabolic syndrome (P < 0.05) compared with subjects without PCOS. Women with PCOS without HA are common in Korea and are less likely to have metabolic dysfunction, insulin resistance and elevated BP. PCOS without HA may be a mild phenotype of PCOS. Therefore, women with PCOS in Korea could have a reduced likelihood of having metabolic syndrome compared with women of other ethnicities.
78 FR 78382 - Steel Nails From China; Determination
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China... U.S.C. 1675(c)), that revocation of the antidumping duty order on steel nails from China would be... 2013), entitled Steel Nails from China: Investigation No. 731-TA-1114 (Review). By order of the...
Guidance on maintaining personal hygiene in nail care.
Malkin, Bridget; Berridge, Pat
Nail care is important in the maintenance of personal hygiene and is an essential aspect of patient care. Confusion about who should perform nail care for patients has resulted in poor practice and cycles of non-activity. This article provides guidance for nurses on performing routine nail care.
77 FR 27080 - Certain Steel Nails From the United Arab Emirates
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-08
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Final)] Certain Steel Nails From... is materially injured by reason of imports from the United Arab Emirates of certain steel nails... of certain steel nails from the United Arab Emirates were being sold at LTFV within the meaning of...
Zhang, Yanan; Ren, Weiqing
2014-12-28
Droplets on a solid surface patterned with microstructures can exhibit the composite Cassie-Baxter (CB) state or the wetted Wenzel state. The stability of the CB state is determined by the energy barrier separating it from the wetted state. In this work, we study the CB to Wenzel transition using the string method [E et al., J. Chem. Phys. 126, 164103 (2007); W. Ren and E. Vanden-Eijnden, J. Chem. Phys. 138, 134105 (2013)]. We compute the transition states and energy barriers for a three-dimensional droplet on patterned surfaces. The liquid-vapor coexistence is modeled using the mean field theory. Numerical results are obtained for surfaces patterned with straight pillars and nails, respectively. It is found that on both type of surfaces, wetting occurs via infiltration of the liquid in a single groove. The reentrant geometry of nails creates large energy barrier for the wetting of the solid surface compared to straight pillars. We also study the effect of surface chemistry, pillar height, and inter-pillar spacing on the energy barrier and compare it with nails.
NASA Astrophysics Data System (ADS)
Zhang, Yanan; Ren, Weiqing
2014-12-01
Droplets on a solid surface patterned with microstructures can exhibit the composite Cassie-Baxter (CB) state or the wetted Wenzel state. The stability of the CB state is determined by the energy barrier separating it from the wetted state. In this work, we study the CB to Wenzel transition using the string method [E et al., J. Chem. Phys. 126, 164103 (2007); W. Ren and E. Vanden-Eijnden, J. Chem. Phys. 138, 134105 (2013)]. We compute the transition states and energy barriers for a three-dimensional droplet on patterned surfaces. The liquid-vapor coexistence is modeled using the mean field theory. Numerical results are obtained for surfaces patterned with straight pillars and nails, respectively. It is found that on both type of surfaces, wetting occurs via infiltration of the liquid in a single groove. The reentrant geometry of nails creates large energy barrier for the wetting of the solid surface compared to straight pillars. We also study the effect of surface chemistry, pillar height, and inter-pillar spacing on the energy barrier and compare it with nails.
Removal of a broken trigen intertan intertrochanteric antegrade nail.
Zheng, Xuan-Lin; Park, Young-Chang; Kim, Sungmin; An, Haemosu; Yang, Kyu-Hyun
2017-02-01
Implant breakage is a serious complication after cephalomedullary nailing for unstable intertrochanteric fracture. Failure usually occurs at the lag screw hole in the nail body. On the other hand, lag screw failure is extremely rare and occurs around the nail-lag screw junction. We experienced rare mechanical failure of the Intertan nail, which showed breakage at the lag screw hole and failure of the integrated compression screw underneath the main lag screw. Copyright © 2016 Elsevier Ltd. All rights reserved.
Genovese, Giovanni; Fai, Dario; Fai, Carlotta; Mavilia, Luciano; Mercuri, Santo R
2016-05-01
Daylight-photodynamic therapy (D-PDT) and ingenol mebutate (IM) are novel therapies directed to actinic keratoses (AK). The purpose of our study was to compare effectiveness, tolerability, cosmetic outcome and patient preference of D-PDT versus IM in the treatment of grade I and II AK. Twenty-seven patients with AK on the face or scalp were enrolled. Each patient received, in a 25 cm(2) target area, D-PDT on right side and IM on left side. Overall 323 AK were treated. Both target areas achieved complete response in 40.47% of the cases and average AK clearance rate was similar for D-PDT and IM (p=0.74). In D-PDT areas mean grade II AK clearance rate was lower compared with that of grade I AK (p=0.015). In IM areas grade I and II AK average clearance rates were similar (p=0.28). At week 1 and month 1, mean local skin responses (LSR) score were higher in areas treated with IM. IM areas showed more severe pain and cosmetic sequelae. D-PDT had similar effectiveness to IM, even if IM demonstrated higher grade II AK clearance rate. Tolerability profile was superior for D-PDT in terms of LSR and pain. D-PDT was more cosmetically acceptable. Patients preferred D-PDT to IM in most cases. © 2016 Wiley Periodicals, Inc.
New Proximal Femoral Compaction Blade Provides Strong Antirotation Stability of the Femoral Head.
Hayashi, Shinya; Hirata, Yukiaki; Okamoto, Daiki; Kakunai, Satoshi; Hashimoto, Shingo; Takayama, Koji; Matsumoto, Tomoyuki; Niikura, Takahiro; Fujishiro, Takaaki; Hiranaka, Takafumi; Nishida, Kotaro; Kuroda, Ryosuke
2017-05-01
This study investigated the mechanical properties of a new rectangular compaction blade and compared this blade with other types of nail. Three types of nail were tested: the Magnum lag screw (Robert Reid Inc, Tokyo, Japan), proximal femoral nail, and Magnum Fid blade (Robert Reid Inc). The nails were inserted into solid rigid polyurethane foam, and the torsional moments were loaded with an Instron testing machine (Instron, Kanagawa, Japan). The force curve was recorded, and the average maximum torque was calculated from this curve. A simulation study was performed with finite element models to determine the mechanism underlying differences in rotational stability. Mechanical testing showed that the new compaction blade had stronger resistance against rotational force than the helical blade and lag screw implants. Finite element analysis also showed that the new compaction blade had stronger resistance to migration of the polyurethane foam cylinder than the other implant types. In addition, the new compaction blade had strong rotational stability. This implant should be useful for the treatment of unstable trochanteric fracture in patients with osteoporosis. [Orthopedics. 2017; 40(3):e491-e494.]. Copyright 2017, SLACK Incorporated.
Changes in nail keratin observed by Raman spectroscopy after Nd:YAG laser treatment.
Shin, Min Kyung; Kim, Tae In; Kim, Wan Sun; Park, Hun-Kuk; Kim, Kyung Sook
2017-04-01
Lasers and photodynamic therapy have been considered a convergence treatment for onychomycosis, which is a fungal infection on the nail bed and nail plate. Laser therapies have shown satisfactory results without significant complications for onychomycosis; however, the mechanism of clearing remains unknown. In this work, we investigated changes in the chemical structure of nail keratin induced by Nd:YAG laser using Raman spectroscopy. Toe nails with onychomycosis were treated with 1064 nm Nd:YAG laser. After laser treatment, the disulfide band (490-590 cm -1 ) of nail keratin was rarely observed or was reduced in intensity. The amide I band (1500-1700 cm -1 ) also showed changes induced by the laser. The α-helical (1652 cm -1 ) structures dominated the β-sheet (1673 cm -1 ) in nontreated nail, but the opposite phenomenon was observed after laser treatment. © 2016 Wiley Periodicals, Inc.
Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures.
Taylor, Benjamin C; Hansen, Dane C; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel
2016-01-01
Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted.
Hamrick, M W
2001-01-01
Paleontological evidence indicates that the evolutionary diversification of mammals early in the Cenozoic era was characterized by an adaptive radiation of distal limb structures. Likewise, neontological data show that morphological variation in distal limb integumentary appendages (e.g., nails, hooves, and claws) can be observed not only among distantly related mammalian taxa but also among closely related species within the same clade. Comparative analysis of nail, claw, and hoof morphogenesis reveals relatively subtle differences in mesenchymal and epithelial patterning underlying these adult differences in distal limb appendage morphology. Furthermore, studies of regulatory gene expression during vertebrate claw development demonstrate that many of the signaling molecules involved in patterning ectodermal derivatives such as teeth, hair, and feathers are also involved in organizing mammalian distal limb appendages. For example, Bmp4 signaling plays an important role during the recruitment of mesenchymal cells into the condensations forming the terminal phalanges, whereas Msx2 affects the length of nails and claws by suppressing proliferation of germinal epidermal cells. Evolutionary changes in the form of distal integumentary appendages may therefore result from changes in gene expression during formation of mesenchymal condensations (Bmp4, posterior Hox genes), induction of the claw fold and germinal matrix (shh), and/or proliferation of epidermal cells in the claw matrix (Msx1, Msx2). The prevalence of convergences and parallelisms in nail and claw structure among mammals underscores the existence of multiple morphogenetic pathways for evolutionary change in distal limb appendages.
NASA Astrophysics Data System (ADS)
Huang, Fan-Feng; Jiang, Shiuh-Jen; Chen, Yen-Ling; Sahayam, A. C.
2018-02-01
This paper describes a flow injection vapor generation (VG) method using inductively coupled plasma mass spectrometry (ICP-MS) for determining As, Cd, Sb, Hg, and Pb in nail polish. The samples for VG were prepared as aqueous slurries of a nail polish (0.5% m/v), thiourea (1% m/v), Co(II) (0.75 μg mL- 1), and HCl (1.2% v/v). Chemical VG of As, Cd, Sb, Hg, and Pb ions, by reduction with tetrahydroborate (3% m/v in 0.2% m/v NaOH), enabled their separation from the slurry. With VG sample introduction, As, Cd, Sb and Hg signals were increased by 1-2 orders (except Pb) compared to solution nebulization due to better sample introduction. Quantifications were performed by VG ICP-MS using isotope dilution and standard addition methods as slopes of calibration plots of analytes in the slurries were higher. Using the reported procedure, samples of three nail polishes purchased locally were analyzed for their levels of As, Cd, Sb, Hg, and Pb. The results obtained were in good agreement with those measured using electrothermal vaporization ICP-MS. In the original nail polish sample, the detection limits, calculated as 3σ of blank measurements, for As, Cd, Sb, Hg, and Pb, estimated from standard addition curves, were 0.06, 0.12, 0.14, 0.2, and 12 ng g- 1, respectively.
Onychomycosis diagnosis using fluorescence and infrared imaging systems
NASA Astrophysics Data System (ADS)
da Silva, Ana Paula; Fortunato, Thereza Cury; Stringasci, Mirian D.; Kurachi, Cristina; Bagnato, Vanderlei S.; Inada, Natalia M.
2015-06-01
Onychomycosis is a common disease of the nail plate, constituting approximately half of all cases of nail infection. Onychomycosis diagnosis is challenging because it is hard to distinguish from other diseases of the nail lamina such as psoriasis, lichen ruber or eczematous nails. The existing methods of diagnostics so far consist of clinical and laboratory analysis, such as: Direct Mycological examination and culture, PCR and histopathology with PAS staining. However, they all share certain disadvantages in terms of sensitivity and specificity, time delay, or cost. This study aimed to evaluate the use of infrared and fluorescence imaging as new non-invasive diagnostic tools in patients with suspected onychomycosis, and compare them with established techniques. For fluorescence analysis, a Clinical Evince (MM Optics®) was used, which consists of an optical assembly with UV LED light source wavelength 400 nm +/- 10 nm and the maximum light intensity: 40 mW/cm2 +/- 20%. For infrared analysis, a Fluke® Camera FKL model Ti400 was used. Patients with onychomycosis and control group were analyzed for comparison. The fluorescence images were processed using MATLAB® routines, and infrared images were analyzed using the SmartView® 3.6 software analysis provided by the company Fluke®. The results demonstrated that both infrared and fluorescence could be complementary to diagnose different types of onychomycosis lesions. The simplicity of operation, quick response and non-invasive assessment of the nail patients in real time, are important factors to be consider for an implementation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-21
... Review AGENCY: Import Administration, International Trade Administration, Department of Commerce. DATES... review and a request to revoke, in part, the antidumping duty order on certain steel nails from the... nails. In addition to the four physical descriptions of steel nails, Petitioner requested three of the...
76 FR 29266 - Certain Steel Nails From the United Arab Emirates
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 Preliminary] Certain Steel Nails... Emirates of certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the... threatened with material injury by reason of LTFV imports of certain steel nails from the United Arab...
Hui, Xiaoying; Lindahl, Åke; Lamel, Sonia; Maibach, Howard I
2013-09-01
This study determined the onychopharmacokinetics, nail absorption, distribution, and penetration of [¹⁴C]-terbinafine HCl in a new topical formulation into/through the human finger nail using the in vitro finite dose model. This study determined the penetration rate of terbinafine HCl from multiple doses of topical formulation applied daily for 14 days. Results showed that the total dose recovery (mass balance) was almost 100%. The concentration of terbinafine HCl in the deeper nail plate (ventral/intermediate layers) and the cotton-pad nail bed samples after the 14-day treatment were 613 ± 145 and (±S.D.) and 27 ± 1.2 µg/cm³ (or 1.9 ± 0.6 µg/cm³ daily) on average, respectively. In comparison with nail concentration data from the literature for other topical terbinatine formulations, our results show that higher amounts of terbinafine HCl reached the deep nail plate and/or the nail bed after a 14-day topical treatment with this topical formulation in vitro.
Tirant, M; Hercogovấ, J; Fioranelli, M; Gianfaldoni, S; Chokoeva, A A; Tchernev, G; Wollina, U; Novotny, F; Roccia, M G; Maximov, G K; França, K; Lotti, T
2016-01-01
Psoriasis is a common chronic inflammatory dermatosis that causes significant distress and morbidity. Approximately 50% of patients with cutaneous psoriasis and 90% of patients with psoriatic arthritis demonstrate nail involvement of their psoriasis. Left untreated, nail psoriasis may progress to debilitating nail disease that leads to not only impairment of function but also on quality of life. We report the case of a 50-year-old male patient with recalcitrant nail dystrophies on the fingers since the age of 40, who responded successfully to Dr. Michaels® product family. The patient had a 35-year history of plaque psoriasis localised on the scalp, ears, groin, limbs, and trunk and with psoriatic arthritis. The nail symptoms consisted of onycholysis, onychomycosis, leukonychia, transverse grooves, nail plate crumbling and paronychia of the periungal skin. This case represents the efficacy and safety of the Dr. Michaels® (Soratinex® and Nailinex®) product family with successful resolution of nail dystrophies and surrounding paronychia with no reported adverse events.
Comparison of three surgical treatment options for unicameral bone cysts in humerus.
Mavčič, Blaž; Saraph, Vinay; Gilg, Magdalena M; Bergovec, Marko; Brecelj, Janez; Leithner, Andreas
2018-04-23
Treatment of unicameral bone cysts (UBC) in the humerus with drainage screws is scarcely reported in the literature. The aim of this retrospective study was to compare drainage screws and alternative treatment methods with respect to the number of required surgical procedures to achieve sufficient UBC healing, postoperative fractures/recurrences/complications, and radiological outcome. Medical archives of two tertiary orthopedic referral centers were screened for all patients who were treated surgically for humeral UBC in the period 1991-2015 with a histologically/cytologically confirmed diagnosis. Sex, age, all surgical procedures, fractures, complications, recurrences, and the final radiological outcome were compared between patients treated with drainage screws, elastic intramedullary nails, or curettage with optional grafting. The study included 106 operated patients with a mean age of 10.3 years, with a mean follow-up of 5.7 years. The average number of UBC-related surgical procedures in sex-matched and age-matched treatment groups was 2.7 with drainage screws, 2.8 with intramedullary nails, and 3.5 with curettage/grafting (P=0.54). Intramedullary nails (odds ratio 0.20) and older age (odds ratio for each year 0.83) predicted a lower risk of postoperative UBC recurrence. Patients with drainage screws had the highest UBC recurrence rates and the lowest rates of changed initial treatment method. There was no difference between the treatment groups in the postoperative fracture rate, complications, or the final radiological outcome. UBC treatment in the humerus therefore requires approximately three surgical procedures, irrespective of the treatment modality chosen. Adding an elastic intramedullary nail to a humeral UBC cyst may reduce recurrence risk and prevent further fractures. Level III - therapeutic retrospective comparative study.
Influence of pH on Transungual Passive and Iontophoretic Transport
SMITH, KELLY A.; HAO, JINSONG; LI, S. KEVIN
2010-01-01
The present study investigated the effects of pH on nail permeability and the transport of ions such as sodium (Na) and chloride (Cl) ions endogenous to nail and hydronium and hydroxide ions present at low and high pH, which might compete with drug transport across hydrated nail plate during iontophoresis. Nail hydration and passive transport of water across the nail at pH 1–13 were assessed. Subsequently, passive and iontophoretic transport experiments were conducted using 22Na and 36Cl ions under various pH conditions. Nail hydration was independent of pH under moderate pH conditions and increased significantly under extreme pH conditions (pH>11). Likewise, nail permeability for water was pH independent at pH 1–10 and an order of magnitude higher at pH 13. The results of passive and iontophoretic transport of Na and Cl ions are consistent with the permselective property of nail. Interestingly, extremely acidic conditions (e.g., pH 1) altered nail permselectivity with the effect lasting several days at the higher pH conditions. Hydronium and hydroxide ion competition in iontophoretic transport was generally negligible at pH 3–11 was significant at the extreme pH conditions studied. PMID:19904826
Gregorí Valdes, Barbara S; Serro, Ana Paula; Gordo, Paulo M; Silva, Alexandra; Gonçalves, Lídia; Salgado, Ana; Marto, Joana; Baltazar, Diogo; Dos Santos, Rui Galhano; Bordado, João Moura; Ribeiro, Helena Margarida
2017-06-01
Onychomycosis is a fungal nail infection. The development of new topical antifungal agents for the treatment of onychomycosis has focused on formulation enhancements that optimize the pharmacological characteristics required for its effective treatment. Polyurethanes (PUs) have never been used in therapeutic nail lacquers. The aim of this work has been the development of new PU-based nail lacquers with antifungal activity containing 1.0% (wt/wt) of terbinafine hydrochloride. The biocompatibility, wettability, and the prediction of the free volume in the polymeric matrix were assessed using a human keratinocytes cell line, contact angle, and Positron Annihilation Lifetime Spectroscopy determinations, respectively. The morphology of the films obtained was confirmed by scanning electron microscopy, while the nail lacquers' bioadhesion to nails was determined by mechanical tests. Viscosity, in vitro release profiles, and antifungal activity were also assessed. This study demonstrated that PU-terbinafine-based nail lacquers have good keratinocyte compatibility, good wettability properties, and adequate free volume. They formed a homogenous film after application, with suitable adhesion to the nail plate. Furthermore, the antifungal test results demonstrated that the terbinafine released from the nail lacquer Formulation A PU 19 showed activity against dermatophytes, namely Trichophyton rubrum. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Sigurgeirsson, B; Ghannoum, M A; Osman-Ponchet, H; Kerrouche, N; Sidou, F
2016-05-01
As onychomycosis is unsightly, this study clinically evaluated whether the antifungal efficacy of amorolfine 5% nail lacquer (NL) was affected by a masking, natural-coloured, cosmetic nail varnish applied 24 h later; in vitro investigations were also performed. Subjects with mild-to-moderate distal subungual toenail onychomycosis were randomised to receive amorolfine 5% NL once weekly with or without cosmetic nail varnish applied 24 h later. After 12-week treatment, antifungal activity of affected toenail clippings was assessed by measurement of zones of inhibition (ZOIs) on Trichophyton mentagrophytes seeded agar plates. Mean diameters were 53.5 mm for the amorolfine 5% NL-alone group (n = 23) and 53.6 mm for amorolfine 5% NL plus cosmetic nail varnish group (n = 25). Also, mycological cultures of subungual debris at week 12 were negative for all subjects in both groups. Most subjects (88%) reported that cosmetic nail varnish masked their infected toenails. Additionally, cadaver human nails coated in vitro with or without cosmetic nail varnish 10 min or 24 h post amorolfine NL application all gave ZOIs on Trichophyton rubrum agar plates representing potent antifungal activity. In conclusion, cosmetic nail varnish applied post amorolfine had no effect on the subungual antifungal activity of amorolfine 5% NL or its penetration through toenails. © 2016 The Authors Mycoses published by Blackwell Verlag GmbH.
Trochanteric fracture-implant motion during healing - A radiostereometry (RSA) study.
Bojan, Alicja J; Jönsson, Anders; Granhed, Hans; Ekholm, Carl; Kärrholm, Johan
2018-03-01
Cut-out complication remains a major unsolved problem in the treatment of trochanteric hip fractures. A better understanding of the three-dimensional fracture-implant motions is needed to enable further development of clinical strategies and countermeasures. The aim of this clinical study was to characterise and quantify three-dimensional motions between the implant and the bone and between the lag screw and nail of the Gamma nail. Radiostereometry Analysis (RSA) analysis was applied in 20 patients with trochanteric hip fractures treated with an intramedullary nail. The following three-dimensional motions were measured postoperatively, at 1 week, 3, 6 and 12 months: translations of the tip of the lag screw in the femoral head, motions of the lag screw in the nail, femoral head motions relative to the nail and nail movements in the femoral shaft. Cranial migration of the tip of the lag screw dominated over the other two translation components in the femoral head. In all fractures the lag screw slid laterally in the nail and the femoral head moved both laterally and inferiorly towards the nail. All femoral heads translated posteriorly relative to the nail, and rotations occurred in both directions with median values close to zero. The nail tended to retrovert in the femoral shaft. Adverse fracture-implant motions were detected in stable trochanteric hip fractures treated with intramedullary nails with high resolution. Therefore, RSA method can be used to evaluate new implant designs and clinical strategies, which aim to reduce cut-out complications. Future RSA studies should aim at more unstable fractures as these are more likely to fail with cut-out. Copyright © 2018 Elsevier Ltd. All rights reserved.
Can, Gulbeyaz; Aydiner, Adnan; Cavdar, Ikbal
2012-07-01
The primary endpoint of this study was to determine predictors of taxane-related nail toxicity. The secondary endpoint was to evaluate the efficacy of the use of frozen gloves and socks in the prevention of taxane-related nail toxicity. This descriptive, interventional, cross-sectional study was conducted with 200 patients. The patients were assigned to the frozen gloves/socks intervention group or control group. Frozen gloves/socks were applied only in hourly taxane-based treatments. The Patients Record Forms of the clinic were used in data collection. Nail changes were graded using the NCI Common Toxicity Criteria for each patient and treatment. Logistic regression analysis was performed to predict the factors that affect nail changes. The majority of the patients enrolled in the study were women diagnosed with breast cancer. The two groups were statistically similar for the cancer diagnosis, type and number of taxane cycles administered. Grade 1 nail toxicity was found in 34%, grade 2 in 11%, and grade 3 in 5.5% patients. Taxane-related nail toxicity was higher in patients who were female, had a history of diabetes, received capecitabine in conjunction with docetaxel and had breast or gynecological cancer diagnosis. Nail changes increased with an increase in the number of taxane cycles administered, BMI and severity of treatment-related neuropathy. The multivariate analysis demonstrated that BMI, breast or ovarian cancer diagnosis and the number of taxane cycles administered were the independent factors for this toxicity. No statistically significant difference in nail toxicity incidence and time to occurrence of nail changes was found between the intervention and the control groups. Copyright © 2011 Elsevier Ltd. All rights reserved.
[Respiratory manifestations of yellow nail syndrome: report of two cases and literature review].
Li, S; Huang, H; Xu, K; Xu, Z J
2018-03-12
Objective: To describe the clinical characteristics of respiratory manifestations of yellow nail syndrome. Methods: We conducted a retrospective analysis of 2 patients with respiratory diseases associated with yellow nail syndrome. Their clinical and chest radiological data were collected. We searched PubMed, Wanfang and CNKI databases with the keywords "yellow nail syndrome, yellow nail and lung" in Chinese and English. And the relevant literatures, including 6 articles in Chinese and 81 articles in English, were reviewed. Results: Our 2 patients were male, one 60 years old and the other 76. Typical yellow nails were present in their fingers, and one of them also showed toe yellow nails. One patient was admitted for refractory respiratory infection and he was diagnosed with diffuse bronchiectasis. The respiratory symptoms could be relieved with antibiotics according to the results of sputum microbiological analysis. The other patient was admitted for cough and exertional dyspnea, and refractory pleural effusions were revealed bilaterally. He received repeated effusion drainage by thoracentesis, and Octreotide was tried recently. A total of 373 cases were reviewed in Chinese and English literatures. Pleural effusions (152 cases) and diffuse bronchiectasis (121 cases) were the most common reported respiratory manifestations. Lymphoedema was present in almost all cases with pleural effusion associated with yellow nail syndrome, and the effusion was usually exudative and lymphocyte predominant. Pleurodesis and decortication were effective for them. But, somatostatin analogues had been tried effectively for these patients recently. On the other hand, literatures showed that diffuse bronchiectasis in yellow nail syndrome was less severe than idiopathic diffuse bronchiectasis, and might benefit from long-term macrolide antibiotics. Conclusions: Yellow nail syndrome is a very rare disorder. Besides yellow nail, respiratory manifestations are the main clinical presentations. Diffuse bronchiectasis and recurrent pleural effusions are the common manifestations.
Nail gun injuries to the head with minimal neurological consequences: a case series.
Makoshi, Ziyad; AlKherayf, Fahad; Da Silva, Vasco; Lesiuk, Howard
2016-03-16
An estimated 3700 individuals are seen annually in US emergency departments for nail gun-related injuries. Approximately 45 cases have been reported in the literature concerning nail gun injuries penetrating the cranium. These cases pose a challenge for the neurosurgeon because of the uniqueness of each case, the dynamics of high pressure nail gun injuries, and the surgical planning to remove the foreign body without further vascular injury or uncontrolled intracranial hemorrhage. Here we present four cases of penetrating nail gun injuries with variable presentations. Case 1 is of a 33-year-old white man who sustained 10 nail gunshot injuries to his head. Case 2 is of a 51-year-old white man who sustained bi-temporal nail gun injuries to his head. Cases 3 and 4 are of two white men aged 22 years and 49 years with a single nail gun injury to the head. In the context of these individual cases and a review of similar cases in the literature we present surgical approaches and considerations in the management of nail gun injuries to the cranium. Case 1 presented with cranial nerve deficits, Case 2 required intubation for low Glasgow Coma Scale, while Cases 3 and 4 were neurologically intact on presentation. Three patients underwent angiography for assessment of vascular injury and all patients underwent surgical removal of foreign objects using a vice-grip. No neurological deficits were found in these patients on follow-up. Nail gun injuries can present with variable clinical status; mortality and morbidity is low for surgically managed isolated nail gun-related injuries to the head. The current case series describes the surgical use of a vice-grip for a good grip of the nail head and controlled extraction, and these patients appear to have a good postoperative prognosis with minimal neurological deficits postoperatively and on follow-up.
Mückley, Thomas; Ullm, Sebastian; Petrovitch, Alexander; Klos, Kajetan; Beimel, Claudia; Fröber, Rosemarie; Hofmann, Gunther O
2007-05-01
Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. This study was conducted to see whether, and if so to what extent, nail design modifications would influence the risk to anatomic structures and the bony coverage of the nail base. Six pairs of thawed fresh-frozen cadaver legs received two different intramedullary nails (N1: straight nail, lateral-medial tip locking; N2: valgus-curved nail, medial-lateral tip locking) under simulated operative conditions. The specimens were dissected; distances between the at-risk structures and the hardware were measured. The hindfoot axis and the volume of the intracalcaneal nail portion were determined with CT. At the plantar entry site, N2 was significantly farther from the flexor hallucis longus tendon (p=0.047), the medial plantar artery (p=0.026), and the lateral plantar nerve (p=0.026) than N1. The lateral-medial calcaneal locking screw of N1 damaged significantly more often the peroneus brevis tendon (p=0.03) than N2. The proximal tip-locking screw, N2, was significantly farther from the anterior tibial artery (p=0.075) and the deep (p=0.047) and superficial peroneal nerves (p=0.009) than N1; N1 was significantly farther from the great saphenous vein (p=0.075) than N2. The distal tip-locking screw, N1. damaged significantly more often the extensor digitorum longus (p=0.007), the anterior tibial artery(p = 0.04), and the deep and superficial peroneal nerves (p=0.03) than N2. CT did not show any significant changes in the hindfoot axis with either device; intracalcaneal nail volumes were similar. A curved nail can increase the distance to at-risk plantar structures. Medial-lateral nail-tip locking appears to have less risk to neurovascular structures. Safer retrograde intramedullary nailing for tibiotalocalcaneal fusion requires knowledge of the structures at risk and appropriate operative technique.
Cohen, Philip R
2011-08-01
Longitudinal erythronychia is a linear red band on the nail plate that originates at the proximal nail fold, traverses the lunula, and extends to the free edge of the nail plate. Longitudinal erythronychia is classified based upon the number of nails affected and the number of red streaks present on each nail as follows: type Ia (monodactylous - single band), type Ib (monodactylous - bifid bands), type IIa (polydactylous - single band), and type IIb (polydactylous - multiple bands). Associated morphologic findings that can be present at the distal tip of the nail with longitudinal erythronychia include fragility, onycholysis, splinter hemorrhage, splitting, subungual keratosis, thinning, and V-shaped nick. Some patients with longitudinal erythronychia seek medical evaluation because of pain in the associated distal digit; however, the linear red nail plate dyschromia is often asymptomatic and the individual is concerned about the cosmetic appearance or distal nail fragility. Longitudinal erythronychia can be a clinical manifestation of an underlying local or systemic condition. Benign tumors (glomus tumor, onychopapilloma, and warty dyskeratoma), malignant neoplasms (malignant melanoma and squamous cell carcinoma), and other conditions (hemiplegia and postsurgical scar) can be associated with monodactylous longitudinal erythronychia or it may be idiopathic or the initial stage of polydactylous longitudinal erythronychia-associated systemic conditions. Polydactylous longitudinal erythronychia is most commonly reported in patients with Darier disease (keratosis follicularis); other associated conditions include acantholytic dyskeratotic epidermal nevus, acantholytic epidermolysis bullosa, acrokeratosis verruciformis of Hopf, amyloidosis, graft-versus-host disease, lichen planus, and pseudobulbar syndrome. Polydactylous longitudinal erythronychia has also been observed as an idiopathic finding. Biopsy of the nail matrix and nail bed may be necessary to establish the diagnosis of a longitudinal erythronychia-associated condition. Indeed, a biopsy should be seriously considered in patients aged more than 50 years who present with a monodactylous longitudinal red band to exclude squamous cell carcinoma. Treatment of longitudinal erythronychia depends on the etiology. For patients with longitudinal erythronychia-associated discomfort or severe nail splitting, a surgical excision may provide not only the underlying diagnosis of the nail dyschromia, but also relief of related symptoms.
Füchtmeier, B; May, R; Fierlbeck, J; Hammer, J; Nerlich, M
2006-01-01
A new humerus nail (Sirus) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed for testing. Three randomized groups were formed (n = 4 pairs). A bending moment of 7.5 Nm and a torsional moment of 8.3 Nm were applied in a test of five loading cycles to all intact bones. Loading was consistently initiated at the distal epiphysis. The consequent deformation at the distal epiphysis was continuously recorded. Then an osteotomy with a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one of each pair was stabilized with the Sirus proximal humerus nail. The other side was fixed with a reference implant. The following groups were created.: Group I: Sirus versus Proximal humerus nail (PHN) with spiral blade. Group II: Sirus versus PHILOS plate. Group III: Sirus versus 4.5 mm AO T-plate. The proximal humerus nail (Sirus) demonstrated significantly higher stiffness values than the reference implants for both bending and torsional load. The following values were recorded at a bending moment of 7.5 Nm: Sirus 14.2 mm, PHN 20.7 mm, PHILOS plate 28.1 mm, 4.5 AO T-plate 29.3 mm p < 0.0012). The values at 8.3 Nm torsional moment were: Sirus 8.5 degrees , PHN 12.3 degrees , PHILOS plate 16.4 degrees , 4.5 AO T-Platte 15.6 degrees (p < 0.002). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the fracture model presented here. Supplementary, the Sirus Nail showed higher stiffness values than the PHN. However, the latter are gaining in importance due to the possibility of minimal invasive implantation. Whether this will be associated with functional advantages requires further clinical investigation.
Barel, A; Calomme, M; Timchenko, A; De Paepe, K; Paepe, K De; Demeester, N; Rogiers, V; Clarys, P; Vanden Berghe, D
2005-10-01
Chronic exposure of the skin to sunlight causes damage to the underlying connective tissue with a loss of elasticity and firmness. Silicon (Si) was suggested to have an important function in the formation and maintenance of connective tissue. Choline-stabilized orthosilicic acid ("ch-OSA") is a bioavailable form of silicon which was found to increase the hydroxyproline concentration in the dermis of animals. The effect of ch-OSA on skin, nails and hair was investigated in a randomized, double blind, placebo-controlled study. Fifty women with photodamaged facial skin were administered orally during 20 weeks, 10 mg Si/day in the form of ch-OSA pellets (n=25) or a placebo (n=25). Noninvasive methods were used to evaluate skin microrelief (forearm), hydration (forearm) and mechanical anisotropy (forehead). Volunteers evaluated on a virtual analog scale (VAS, "none=0, severe=3") brittleness of hair and nails. The serum Si concentration was significantly higher after a 20-week supplementation in subjects with ch-OSA compared to the placebo group. Skin roughness parameters increased in the placebo group (Rt:+8%; Rm: +11%; Rz: +6%) but decreased in the ch-OSA group (Rt: -16%; Rm: -19%; Rz: -8%). The change in roughness from baseline was significantly different between ch-OSA and placebo groups for Rt and Rm. The difference in longitudinal and lateral shear propagation time increased after 20 weeks in the placebo group but decreased in the ch-OSA group suggesting improvement in isotropy of the skin. VAS scores for nail and hair brittleness were significantly lower after 20 weeks in the ch-OSA group compared to baseline scores. Oral intake of ch-OSA during the 20 weeks results in a significant positive effect on skin surface and skin mechanical properties, and on brittleness of hair and nails.
Han, Bing; Shi, Zhigang; Fu, Yu; Ye, Yong; Jing, Juehua; Li, Jun
2017-01-01
Abstract Background: Although the method has been used widely, one of the greatest challenges for intramedullary nailing is to position the distal locking screw. A new technology, the electromagnetic navigation system, is a radiation-free way to locate the position of the drill bit and provide 3-dimensional real-time feedback of location and orientation of the drill bit relative to the locking holes. The purpose of our study was to evaluate the reliability and efficiency of the free-hand technique compared to the new electromagnetic navigation system. Methods: Fifty-four patients with femoral fracture who needed treatment with intramedullary nails were divided into 2 groups. One group including 26 patients underwent distal locking using the standard free-hand method, whereas the electromagnetic navigation system was used with the other 29 patients. Intraoperative fluoroscopy exposure times, screw insertion times, and healing times were recorded; these parameters were used for comparison between the 2 groups. Results: There were 17 males and 9 females who had femoral intramedullary nails using the free-hand technique, whereas 21 males and 8 females received intramedullary nails using the electromagnetic navigation system. The mean time of distal locking was 19.5 ± 6.0 minutes in the free-hand (FH) group, whereas the time was 6.1 ± 1.4 minutes in the electromagnetic (ET) group. The exposure time for the FH group was 26.8 ± 13.3 seconds and 2.2 ± 1.1 seconds for the ET group. Healing time proved to be comparable in the FH and ET groups (16.4 ± 3.7 weeks vs 15.1 ± 2.8 weeks). Conclusion: Under the premise of achieving the same effect, the electromagnetic navigation system has the advantage of less distal locking time and less radiation dose. PMID:28723755
Han, Bing; Shi, Zhigang; Fu, Yu; Ye, Yong; Jing, Juehua; Li, Jun
2017-07-01
Although the method has been used widely, one of the greatest challenges for intramedullary nailing is to position the distal locking screw. A new technology, the electromagnetic navigation system, is a radiation-free way to locate the position of the drill bit and provide 3-dimensional real-time feedback of location and orientation of the drill bit relative to the locking holes. The purpose of our study was to evaluate the reliability and efficiency of the free-hand technique compared to the new electromagnetic navigation system. Fifty-four patients with femoral fracture who needed treatment with intramedullary nails were divided into 2 groups. One group including 26 patients underwent distal locking using the standard free-hand method, whereas the electromagnetic navigation system was used with the other 29 patients. Intraoperative fluoroscopy exposure times, screw insertion times, and healing times were recorded; these parameters were used for comparison between the 2 groups. There were 17 males and 9 females who had femoral intramedullary nails using the free-hand technique, whereas 21 males and 8 females received intramedullary nails using the electromagnetic navigation system. The mean time of distal locking was 19.5 ± 6.0 minutes in the free-hand (FH) group, whereas the time was 6.1 ± 1.4 minutes in the electromagnetic (ET) group. The exposure time for the FH group was 26.8 ± 13.3 seconds and 2.2 ± 1.1 seconds for the ET group. Healing time proved to be comparable in the FH and ET groups (16.4 ± 3.7 weeks vs 15.1 ± 2.8 weeks). Under the premise of achieving the same effect, the electromagnetic navigation system has the advantage of less distal locking time and less radiation dose.
Daner, William E; Owen, John R; Wayne, Jennifer S; Graves, Ryan B; Willis, Mark C
2017-12-01
For proximal femur fractures, long cephalomedullary nails (CMNs) are often selected to avoid a diaphyseal stress riser at the tip of a shorter nail. Secondary peri-implant fracture rates for long and short CMN have not been shown to differ clinically. This study biomechanically compares both CMN in a cadaveric model. Ten matched pairs of cadaveric femora with short or long CMN were axially loaded and internally rotated to failure. Resulting fractures involved distal interlocking screws of the short and long CMN. Energy and rotation to failure were significantly greater for short CMN. Torque at failure trended higher for short CMN but not significantly. No statistical difference was detected in stiffness of the short and long CMN. A greater risk of secondary fracture is not indicated for short versus long CMN under torsional stress. Short CMN may be suitable in the younger patient.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... coils using materials such as plastic, paper, or wire. Certain steel nails subject to this investigation... plastic or steel washers (``caps'') already assembled to the nail, having a bright or galvanized finish, a... Initiation Notice,\\2\\ by removing the language referring to the packaging characteristics of certain nails...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Steel Nails From China... steel nails from China would be likely to lead to continuation or recurrence of material injury within a...
[The present study situation and application prospect of nail analysis for abused drugs].
Chen, Hang; Xiang, Ping; Shen, Min
2010-10-01
In forensic toxicology analysis, various types of biological samples have their own special characteristics and scope of applications. In this article, the physiological structure of nails, methods for collecting and pre-processing samples, and for analyzing some poisons and drugs in the nails are reviewed with details. This paper introduces the influence factors of drug abuse of the nails. The prospects of its further applications are concluded based on the research results. Nails, as an unconventional bio-sample without general application, show great potential and advantages in forensic toxicology.
Dowdy, Art; Tincani, Matt; Nipe, Timothy; Weiss, Mary Jane
2018-06-17
Personal hygiene routines, such as nail cutting, are essential for maintaining good health. However, individuals with autism spectrum disorder (ASD) and other developmental disabilities often struggle to comply with essential, personal hygiene routines. We conducted a systematic replication of Schumacher and Rapp (2011), Shabani and Fisher (2006), and Bishop et al. (2013) to evaluate an intervention that did not require escape extinction for increasing compliance with nail cutting. With two adolescents diagnosed with ASD who resisted nail cutting, we evaluated the effects of delivering a preferred edible item contingent on compliance with nail cutting. Results indicated that the treatment reduced participants' escape responses and increased their compliance with nail cutting. © 2018 Society for the Experimental Analysis of Behavior.
[Tibio-talo-calcaneal arthrodesis with the retrograde intramedullary nail MEDIN].
Popelka, S; Vavřík, P; Landor, I; Bek, J; Popelka ml, S; Hromádka, R
2013-01-01
When the talus and the talocalcaneal joint are both affected, their fusion is the method of treatment. Ankle arthrodesis is carried out using various osteosynthetic materials such as external fixators, screws and plates. One of the options is retrograde nailing. Tibio-talo-calcaneal arthrodesis is frequently indicated in patients with rheumatoid arthritis (RA) in whom both the talus and the subtalar joint are often affected. A retrograde nail for tibio-talo-calcaneal arthrodesis was developed at our department in cooperation with MEDIN Company. This is a titanium double-curved nail, with the distal part bent at 8 degrees ventrally and 10 degrees laterally. It is inserted from the transfibular approach. Sixty-two patients, 35 women and 27 men, were treated at our department from 2005. Since one patient had bilateral surgery, 63 ankles were included. The indications for arthrodesis involved rheumatoid arthritis in 42, post-traumatic arthritis in 10, failed ankle arthrodesis in two and failed total ankle arthroplasty in five ankles; tibial stress fractures close above the ankle in two RA patients, one patient with dermatomyositis and one with lupus erythematodes. The average age at the time of surgery was 64.2 years (range, 30 to 80). The average follow-up was 4.5 years (range, 1 to 9 years), Satisfaction with the treatment outcome and willingness to undergo surgery on the other side were reported by 82% of the patients. The AOFAS score improved from 35 to 74 points. Three (4.8%) patients complained of painful feet due to the fact that exact correction of the calcaneus was not achieved and the heel after arthrodesis remained in a slightly varus position. Of them, two had a failed total ankle arthroplasty. Post-operative complications included early infection managed by antibiotic treatment and early surgical revision with irrigation.in two (3.2%) RA patients, who were undergoing biological therapy. Late infection developed at 2 to 3 years after surgery in three (4.3%) patients (two had RA). The infection was managed by revision surgery with nail removal and irrigation. All patients healed well. Necrosis of the talus and development of a pseudoarthrosis were recorded in four (6.4%) patients, who subsequently underwent nail removal and repeat fusion using an external fixator. Retrograde nailing for tibio-talo-calcaneal arthrodesis is used by many authors. Its complication rate is comparable with the other methods of arthrodesis. The use of tibio-talo-calcaneal arthrodesis aims at a painless and stable joint. Arthrodesis of the talus and the subtalar joint using a retrograde nail is an effective surgical treatment of the joints affected. It is especially recommended for RA patients who have severe deviations. Retrograde nailing provides a stable osteosynthesis which does not require plaster cast immobilisation. The double-curved nail allows for its insertion in the solid part of the calcaneus and helps avoiding injury to the neurovascular bundle.
Lahfa, M; Bulai-Livideanu, C; Baran, R; Ortonne, J P; Richert, B; Tosti, A; Piraccini, B M; Szepietowski, J C; Sibaud, V; Coubetergues, H; Voisard, J J; Paul, C
2013-01-01
Toenail onychomycosis is highly prevalent, with 14-28% of people aged 60 or over suffering from the disease. Use of a topical antifungal alone in toenail onychomycosis is associated with low cure rates. This may be due to limited penetration of the topical antifungal through the diseased nail. The objective of the present study was to compare two treatment modalities to obtain diseased nail chemical avulsion in toenail onychomycosis. In this European, multicenter, randomized, parallel-group, open-label, active-controlled study, male or female adult patients with distal-lateral or lateral subungual dermatophyte onychomycosis on at least 12.5% of the great toenail were randomized either to a 40% urea ointment with plastic dressing group (n = 53) or to a bifonazole-urea ointment group (n = 52). The ointments were applied daily for a maximum of 3 weeks according to the summary of product characteristics. After assessment of infected nail debridement, topical antifungal treatment with bifonazole cream was applied daily in both groups for 8 weeks. 102 patients were evaluated, i.e. 51 in the 40% urea ointment with plastic dressing group and 51 in the bifonazole-urea group. The primary end point was complete removal of the nail plate at day 21 (D21). Secondary end points were: complete cure and mycological cure evaluated at D105. Ease of use and local tolerability were also assessed. Complete removal of the clinically infected target nail plate area, assessed by blinded evaluators, was significantly higher in the 40% urea ointment with plastic dressing group (61.2%) than in the control group (39.2%), showing the superiority of 40% urea ointment with plastic dressing (p = 0.028). The same results were observed in the per-protocol population (63.0 vs. 36.6%; p = 0.014). Complete removal of the infected area assessed by the investigator at D21 showed a significantly higher success rate in patients treated with 40% urea ointment with plastic dressing (86.3%) as compared to patients treated with bifonazole-urea (60.8%), confirming the superiority of 40% urea ointment with plastic dressing (p = 0.004). At D105, the complete cure of onychomycosis, a criterion combining clinical and mycological assessments, showed a success rate of 27.7% for 40% urea ointment with plastic dressing versus 20.8% for the control group. No statistical difference was observed between the two treatment groups. The number of patients with at least one adverse event was twice as high in the bifonazole-urea group in comparison to the 40% urea ointment with plastic dressing group. Overall assessment of local tolerability by the investigator was considered good/very good in 98.0% of the 40% urea ointment with plastic dressing patients versus 90.4% of the bifonazole-urea patients, at D21, with no significant difference between both groups. This study shows the superiority of 40% urea ointment with plastic dressing to bifonazole-urea ointment for complete removal of the infected target nail assessed by blinded evaluators and by the investigators. Further studies are needed to assess the impact of preliminary chemical nail avulsion on the efficacy of topical treatment of onychomycosis as assessed by complete cure at 1 year. Copyright © 2013 S. Karger AG, Basel.
High-resolution ultrasonography in assessment of nail-related disorders.
Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J
2012-09-01
Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.
Amarathunga, J P; Schuetz, M A; Yarlagadda, K V D; Schmutz, B
2015-04-01
Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of tibia. Selection of the correct nail insertion point is important for axial alignment of bone fragments and to avoid iatrogenic fractures. However, the standard entry point (SEP) may not always optimise the bone-nail fit due to geometric variations of bones. This study aimed to investigate the optimal entry for a given bone-nail pair using the fit quantification software tool previously developed by the authors. The misfit was quantified for 20 bones with two nail designs (ETN and ETN-Proximal Bend) related to the SEP and 5 entry points which were 5 mm and 10 mm away from the SEP. The SEP was the optimal entry point for 50% of the bones used. For the remaining bones, the optimal entry point was located 5 mm away from the SEP, which improved the overall fit by 40% on average. However, entry points 10 mm away from the SEP doubled the misfit. The optimised bone-nail fit can be achieved through the SEP and within the range of a 5 mm radius, except posteriorly. The study results suggest that the optimal entry point should be selected by considering the fit during insertion and not only at the final position. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Arthrodesis in septic knees using a long intramedullary nail: 17 consecutive cases.
Leroux, B; Aparicio, G; Fontanin, N; Ohl, X; Madi, K; Dehoux, E; Diallo, S
2013-06-01
Intramedullary nailing using long or modular nails is the most reliable mean of achieving femorotibial fusion. Here, we report the operative, clinical, functional, and radiological outcomes of 17 long intramedullary nail arthodeses in patients with infection. Clinical and functional outcomes after long intramedullary nailing are at least as good as those obtained using other implants. We retrospectively reevaluated 17 patients after unilateral two-stage knee arthrodesis with a long titanium intramedullary nail and autologous bone grafting. We evaluated satisfaction, leg length discrepancy, and function (Lequesne and WOMAC indices). Radiographs were obtained to assess fusion, time to fusion, and femorotibial angles. No cases of material failure were recorded. One or more complications occurred in seven patients. Mean limb shortening was 27.6mm. Of the 17 patients, 15 were satisfied with the procedure. The mean Lequesne index was 10.5/24 and the mean overall WOMAC score was 26/88. Fusion was achieved in 16 patients, with a mean time to fusion of 5 months. Mean femorotibial angles were 178.6° of varus and 1.9° of flexion. This simple and rapid surgical technique provides functional outcomes similar to those obtained using modular nails. The fusion rate is high. Nail extraction is simple and causes minimal damage, in contrast to modular nails. Increased attention to misalignment is needed. Level IV, retrospective study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Application of soil nails to the stability of mine waste slopes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tant, C.R.; Drumm, E.C.; Mauldon, M.
1996-12-31
The traditional soil nailed structure incorporates grouted or driven nails, and a wire mesh reinforced shotcrete facing to increase the stability of a slope or wall. This paper describes the construction and monitoring of a full-scale demonstration of nailing to stabilize coal mine spoil. The purpose of the investigation is to evaluate the performance of nailed slopes in mine spoil using methods proven for the stabilization of soil walls and slopes. The site in eastern Tennessee is a 12 meter high slope of dumped fill, composed of weathered shale chips, sandstone, and coal. The slope was formed by {open_quotes}pre-regulatory{close_quotes} contourmore » surface mining operations and served as a work bench during mining. The material varies in size from silt to boulders, and has a small amount of cohesion. Portions of the mine spoil slope have experienced slope instability and erosion which have hampered subsequent reclamation activities. Three different nail spacings and three different nail lengths were used in the design. The 12 meter high structure is instrumented to permit measurement of nail strain, and vertical inclinometer readings and survey measurements will be used for the detection of ground movement. The results of this study will aid in the development of design recommendations and construction guidelines for the application of soil nailing to stabilize mine spoil.« less
Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View.
Callahan, Ryan; Juliano, Paul; Aydogan, Umur; Clayton, Justin
2018-04-01
Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Level V: Expert opinion.
Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad
2018-05-01
Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
Withdrawal strength of ring-shank nails embedded in southern pine lumber
M. J. Skulteti; D. A. Bender; S. G. Winistorfer; D. G. Pollock
1997-01-01
Ring-shank nails are used extensively in post-frame construction due to their superior performance, yet surprisingly little testing has been done on nail sizes above 12d Experience in the post-frame industry suggests that published allowable design values for ring-shank nails may be overly conservative and need revision. The goal of the research reported herein was to...
Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.
Pelton, Kevin; Hofer, Jason K; Thordarson, David B
2006-10-01
Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.
Habit tic nail deformity - a rare presentation in an 8 year old boy.
El-Heis, S; Abadie, Al
2016-11-15
Habit tic nail deformity is a nail dystrophy resulting from habitual, repetitive trauma to the nail. It is usually acquired in adulthood, however, we report a case of habit tic nail deformity in an 8 year old boy. The diagnosis was made clinically with further history revealing that the boy repeatedly rubbed his thumbnails and pushed the cuticles. Emollient cream (Balneum®) was recommended twice daily and both the patient and his mother were educated on the behavioral nature of this condition. There was marked improvement at 6 months of treatment and further improvement at 12 months.We note that habit tic nail deformity is not exclusive to adults. Diagnosis can be made clinically. History and physical examination provide valuable clues and psychosocial links must be explored and addressed. Management is challenging and compliance with treatment is variable. Patient education, barrier methods, and behavioral therapy can be helpful in preventing further trauma to the nails.
Penetrating brain injury caused by nail guns: two case reports and a review of the literature.
Luo, Wei; Liu, Hai; Hao, Shuyu; Zhang, Ying; Li, Jingsheng; Liu, Baiyun
2012-01-01
To the best of the authors' knowledge, there are few case reports of penetrating brain injuries (PBI) caused by nail guns and these have usually involved incomplete penetration of the skull. Complete penetration of a nail into the intracranial cavity is extremely rare. Here, two such cases are presented. In the first, the nail entered through the right temporal bone, lodged in the right temporal lobe and was removed via craniotomy with intra-operative ultrasound guidance. In the second, the nail destroyed the left parietal bone, damaged the left internal capsule and lodged in the left temporal lobe near the left petrous apex and the brain stem. According to the latest literature retrieval, this is the first reported case of nail-gun injury to the internal capsule. The position of the nail precluded removal without further neurologic damage. Treatment strategies designed to optimize outcome, with or without surgery, and possible complications are discussed in this report.
Effectiveness of exchange K-nail and augmented plating in aseptic femoral diaphyseal non-union.
Sancheti, K H; Pradhan, Chetan; Patil, Atul; Puram, Chetan; Bharti, Parkalp; Sancheti, Parag; Shyam, Ashok
2017-08-01
Femoral diaphyseal non-unions present difficult scenario to manage. There are multiple options but most of them still report varying incidences of failure. We combined the principles of augmented plating and exchange nailing and aim to study the effectiveness of this technique. A retrospective study at a tertiary trauma centre was conducted. Seventy patients (60 men, 10 women), average age 40.7±15.27 years (range 18-81 years) with diaphyseal femoral fracture non-unions treated between July 2010 and January 2015 were reviewed. The average interval between first and the last surgery was 18.07±17.65 months (range 4-96 months). Forty six patients had hypertrophic non-union and 24 patients had atrophic non-union. Twenty one patients had undergone a prior surgery for non-union, 13 dynamisation, 4 bone grafting, 1 augmented plating and 3 exchange nailing. Non-unions were treated with implant removal, freshening of bone edges and exchange K-nailing and augmented plating. Autologous bone grafting and raising of osteoperiosteal flaps was done in all cases. Outcome measures were radiographic evidence of fracture union at minimum three out of four cortices, knee range of motion as compared to opposite knee, and study of complications. All patients demonstrated radiographic evidence of fracture union with an average time of 16.77±2.38 weeks (range 12-26 weeks). Mean knee range of motion of unaffected limb was 126±9.76° (range 90-140°) while in operated limb it was 121.1±11.36° (range 80-140°), p>0.01. Patients with hypertrophic non-unions, prior surgery for non-union and supra- or infra-isthmal non-unions had shorter union time. Two patients had superficial infection which was managed by superficial debridement and two patients had pain at proximal nail tip site which was managed by anti-inflammatory medication. None of the patients required additional surgery for implant removal. Exchange K nailing with Bone graft and additional plating technique for non-union diaphyseal femur fracture achieved good union rates with minimal complication. In our series none of the patient required revision and the technique probably will further minimise the revision rates compared to current options for non-union femur. © 2017 Elsevier Ltd. All rights reserved.
Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco
2015-01-01
Background Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. Methods and Findings In this trial, 367 parasite-negative school-aged children (aged 6–15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to 1.04). The intensive follow-up and monitoring during this study made it such that the assessment of the observed intervention benefits was under rather ideal circumstances, and hence the study could possibly overestimate the effects when compared to usual conditions. Conclusions Handwashing with soap at key times and weekly nail clipping significantly decreased intestinal parasite reinfection rates. Furthermore, the handwashing intervention significantly reduced anemia prevalence in children. The next essential step should be implementing pragmatic studies and developing more effective approaches to promote and implement handwashing with soap and nail clipping at larger scales. PMID:26057703
Mahmud, Mahmud Abdulkader; Spigt, Mark; Bezabih, Afework Mulugeta; Pavon, Ignacio Lopez; Dinant, Geert-Jan; Velasco, Roman Blanco
2015-06-01
Intestinal parasitic infections are highly endemic among school-aged children in resource-limited settings. To lower their impact, preventive measures should be implemented that are sustainable with available resources. The aim of this study was to assess the impact of handwashing with soap and nail clipping on the prevention of intestinal parasite reinfections. In this trial, 367 parasite-negative school-aged children (aged 6-15 y) were randomly assigned to receive both, one or the other, or neither of the interventions in a 2 × 2 factorial design. Assignment sequence was concealed. After 6 mo of follow-up, stool samples were examined using direct, concentration, and Kato-Katz methods. Hemoglobin levels were determined using a HemoCue spectrometer. The primary study outcomes were prevalence of intestinal parasite reinfection and infection intensity. The secondary outcome was anemia prevalence. Analysis was by intention to treat. Main effects were adjusted for sex, age, drinking water source, latrine use, pre-treatment parasites, handwashing with soap and nail clipping at baseline, and the other factor in the additive model. Fourteen percent (95% CI: 9% to 19%) of the children in the handwashing with soap intervention group were reinfected versus 29% (95% CI: 22% to 36%) in the groups with no handwashing with soap (adjusted odds ratio [AOR] 0.32, 95% CI: 0.17 to 0.62). Similarly, 17% (95% CI: 12% to 22%) of the children in the nail clipping intervention group were reinfected versus 26% (95% CI: 20% to 32%) in the groups with no nail clipping (AOR 0.51, 95% CI: 0.27 to 0.95). Likewise, following the intervention, 13% (95% CI: 8% to 18%) of the children in the handwashing group were anemic versus 23% (95% CI: 17% to 29%) in the groups with no handwashing with soap (AOR 0.39, 95% CI: 0.20 to 0.78). The prevalence of anemia did not differ significantly between children in the nail clipping group and those in the groups with no nail clipping (AOR 0.53, 95% CI: 0.27 to 1.04). The intensive follow-up and monitoring during this study made it such that the assessment of the observed intervention benefits was under rather ideal circumstances, and hence the study could possibly overestimate the effects when compared to usual conditions. Handwashing with soap at key times and weekly nail clipping significantly decreased intestinal parasite reinfection rates. Furthermore, the handwashing intervention significantly reduced anemia prevalence in children. The next essential step should be implementing pragmatic studies and developing more effective approaches to promote and implement handwashing with soap and nail clipping at larger scales.
Infected Textiloma, 35 Years after the Operation for Femur Fracture, an extermly rare occurance.
Sadeghifar, Amir R; Saeed, Ali R
2013-09-01
Retained gauze after surgery is an uncommon error and it may be associated with many complications. We are reporting our case to call attention to the fact that retained gauze may become symptomatic even after a very long interval. Herein we report on a patient who developed infection and fistula with discharge from this error 35 years after a surgery for femur fracture and insertion of a IM nail. The diagnosis was easily made because of a marker in the gauze. Removal of the gauze and irrigation and debridement of the wound in two stages led to complete recovery of the patient as was shown in the 1 year follow up. Retained gauze after surgery is a preventable complication and may be asymptomatic for a very long period, but can become a complication post-operatively at any time. Hence, if diagnosed immediately after the surgery or at any other time, the gauze should be removed.
Infected Textiloma, 35 Years after the Operation for Femur Fracture, an extermly rare occurance
Sadeghifar, Amir R; Saeed, Ali R
2013-01-01
Retained gauze after surgery is an uncommon error and it may be associated with many complications. We are reporting our case to call attention to the fact that retained gauze may become symptomatic even after a very long interval. Herein we report on a patient who developed infection and fistula with discharge from this error 35 years after a surgery for femur fracture and insertion of a IM nail. The diagnosis was easily made because of a marker in the gauze. Removal of the gauze and irrigation and debridement of the wound in two stages led to complete recovery of the patient as was shown in the 1 year follow up. Retained gauze after surgery is a preventable complication and may be asymptomatic for a very long period, but can become a complication post-operatively at any time. Hence, if diagnosed immediately after the surgery or at any other time, the gauze should be removed. PMID:25207284
Feng, Jun; Yu, Guangrong
2015-09-01
To review the cause, treatment, and prevention of complications of retrograde intramedullary nail fixation for tibiotalocalcaneal arthrodesis and enhance the recognition on the complications of tibiotalocalcaneal arthrodesis. The recent literature concerning intramedullary nail fixation for tibiotalocalcaneal arthrodesis was consulted and reviewed. There are intraoperative and postoperative complications of intramedullary nail fixation for tibiotalocalcaneal arthrodesis, and the causes, treatment, and prevention of complications are various. Progress of retrograde intramedullary nail fixation increases the successful rate of tibiotalocalcaneal arthrodesis. However, there is still a high complication rate, so strict preoperative assessment and skilled surgical technique are necessary to prevent complications.
Intramedullary nailing: experience in 427 patients.
Lambiris, E; Tyllianakis, M; Megas, P; Panagiotopoulos, E
1996-01-01
In the Orthopaedic Department in Patras University 427 intramedullary nailings in the lower limbs were performed between 1989 and 1994 and retrospectively reviewed to evaluate the range of complications. One hundred and seventy-two were nailings of the femur; 80 gamma nails mainly for subtrochanteric and intertrochanteric with subtrochanteric extension fractures were included, (total 252/59%); 175 (41%) were nailings of the tibia. Union was achieved in all case. Overall the complication rate in this series was 3.3% (14 cases) and included infection (4 cases), neuropraxia (2 cases), implant failure (5 cases), limb length deficiency (2 cases) and malrotation (1 case).
Distal tibial fractures and non-unions treated with shortened intramedullary nail.
Megas, P; Zouboulis, P; Papadopoulos, A X; Karageorgos, A; Lambiris, E
2003-01-01
We reviewed 18 patients, 14 with acute fractures and four with non-union of the distal tibia, treated between 1990 and 2001 with a shortened, reamed intramedullary nail. The mean follow-up was 38 (8-144) months. The fractures united at an average of 16 (12-18) weeks and the non-unions at 20 (12-30) weeks. Two patients required nail dynamization. No limb shortening nor material failures were seen. All patients returned to normal daily activities. Although technically demanding, intramedullary nailing for distal tibial fractures and non-unions with a shortened nail represents a safe and reliable method.
Congenital yellow nail syndrome: a case report and its relationship to nonimmune fetal hydrops.
Nanda, Arti; Al-Essa, Fahad H; El-Shafei, Wael M; Alsaleh, Qasem A
2010-01-01
Yellow nail syndrome (YNS) is an uncommon disorder characterized by a triad of nail dystrophy, lymphedema, and pleural effusion. It is rare in children and congenital occurrence of YNS has been very rarely described. We report a 2-year-old Arab boy having congenital yellow nail syndrome with mild facial dysmorphism and bilateral conjunctival pigmentation born to consanguineous parents. One of his older siblings had died of nonimmune fetal hydrops (NIFH). The case supports the genetic basis of yellow nail syndrome with a possible relationship to nonimmune fetal hydrops. © 2010 Wiley Periodicals, Inc.
Enhanced econazole penetration into human nail by 2-n-nonyl-1,3-dioxolane.
Hui, Xiaoying; Chan, Thomas C K; Barbadillo, Sherry; Lee, Christine; Maibach, Howard I; Wester, Ronald C
2003-01-01
This study determines the enhancing effects of 2-n-nonyl-1,3-dioxolane on the penetration of econazole, an antifungal drug, into the deeper layers of the human nail where fungal infection resides. Aliquots (10 microL) of Econail lacquer formulation containing 0.45 mg of [(14)C]-econazole with 18% 2-n-nonyl-1,3-dioxolane (test group) or without 2-n-nonyl-1,3-dioxolane (control group) were applied twice daily for 14 days to human nails that had been washed with ethanol before each morning's application. The hydration of the nail sample was well controlled to simulate normal physiological conditions. After 14 days of dosing, the inner ventral section of the nail plate was assayed for absorbed drug content, using a micrometer-controlled drilling and nail powder removal system. The mass balance values of [(14)C]-econazole in this study were 90.8 and 96.4% for the test and control groups, respectively. The weight-normalized econazole content in the ventral/intermediate nail plate center in the test group was 6-fold greater than that in the control (p = 0.008). The total econazole absorbed into the supporting bed cotton ball in the test group was nearly 200-fold greater than that in the control group (p = 0.008) over the 14-day period. The amount of econazole after dosing in the inner part of the human nail (potential diseased area) was 11.1 +/- 2.6 (SD) microg/mg of nail powder with 2-n-nonyl-1,3-dioxolane in the lacquer and 1.78 +/- 0.32 microg/mg without 2-n-nonyl-1,3-dioxolane (p = 0.008). The surface nail contained more econazole (p = 0.004), that is, nonabsorbed drug, where 2-n-nonyl-1,3-dioxolane was not part of the dosing solution. Econazole in the support bed under the nail (the total absorbed dose) was 47.5 +/- 22.0 mg in the lacquer with 2-n-nonyl-1,3-dioxolane and 0.2 +/- 0.1 mg in the lacquer without 2-n-nonyl-1,3-dioxolane (p = 0.008). Moreover the concentration in the deep nail layer in the test group is 14,000 times higher than minimum inhibitory concentration (MIC) believed necessary to inhibit the growth of infecting fungi (Dermatophytes species). In a subsequent study, [(14)C]-dioxolane did not penetrate the nail well. Therefore, the mechanism of enhancement of econazole penetration is at the formulation/nail interface. Copyright 2002 Wiley-Liss, Inc. and the American Pharmaceutical Association
ERIC Educational Resources Information Center
Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin
2013-01-01
This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were…
ERIC Educational Resources Information Center
Sisman, Fatma Nevin; Tok, Ozlem; Ergun, Ayse
2017-01-01
Nail-biting is one of the most common behavioral problems in children. This study aimed to examine factors affecting nail-biting among adolescents and the effects of psychological state and social support on nail-biting. This cross-sectional study was conducted between January and May of 2014 in seven schools in Istanbul (N = 724). Data were…
Kamarianakis, Z; Buliev, I; Pallikarakis, N
2011-05-01
Closed intramedullary nailing is a common technique for treatment of femur and tibia fractures. The most challenging step in this procedure is the precise placement of the lateral screws that stabilize the fragmented bone. The present work concerns the development and the evaluation of a method to accurately identify in the 3D space the axes of the nail hole canals. A limited number of projection images are acquired around the leg with the help of a C-arm. On two of them, the locking hole entries are interactively selected and a rough localization of the hole axes is performed. Perpendicularly to one of them, cone-beam computed tomography (CBCT) reconstructions are produced. The accurate identification and localization of the hole axes are done by an identification of the centers of the nail holes on the tomograms and a further 3D linear regression through principal component analysis (PCA). Various feature-based approaches (RANSAC, least-square fitting, Hough transform) have been compared for best matching the contours and the centers of the holes on the tomograms. The robustness of the suggested method was investigated using simulations. Programming is done in Matlab and C++. Results obtained on synthetic data confirm very good localization accuracy - mean translational error of 0.14 mm (std=0.08 mm) and mean angular error of 0.84° (std=0.35°) at no radiation excess. Successful localization can be further used to guide a surgeon or a robot for correct drilling the bone along the nail openings. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Succi, Isabella B; Bernardes-Engemann, Andréa R; Orofino-Costa, Rosane
2013-05-01
Onychomycosis constitutes up to 50% of all nail disorders. Toenails are generally affected, mostly due to dermatophytes. Terbinafine is the most potent antifungal agent in vitro against dermatophytes. There are few randomised controlled trials using a non-continuous dose of terbinafine. The aim of this open-label pilot study was to reduce the total drug amount, the collateral effects and, specially, the costs; albeit maintaining the same efficacy of the standard regimens. Compare the outcomes of two different intermittent regimens with the same total amount of the medication (42 tablets in 6 months). Forty-one patients were divided into the following groups: terbinafine 250 mg day(-1) , for 7 days, monthly or terbinafine 500 mg day(-1) , once daily, for 7 days, every 2 months, both plus nail abrasion during 6 months. The efficacy was evaluated at months 6, 12 and 18 using the disease free nail criteria. Total cure = group I: eight patients (44.4%) and group II: eight patients (44.4%). Partial cure = group I: five patients (27.8%) and group II: four patients (22.2%). Treatment failure = group I: five patients (27.8%) and group II: three patients (16.7%). Recurrence = group I: zero patients (0.0%) and group II: three patients (16.7%). Two intermittent dosing regimens of terbinafine plus nail abrasion proved to be an alternative statistically effective, safe and with reduced drug costs for dermatophytes toenail onychomycosis. © 2012 Blackwell Verlag GmbH.
Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures
Taylor, Benjamin C.; Hansen, Dane C.; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel
2016-01-01
Background Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. Methods In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Results Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. Conclusions This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted. PMID:27528840
Lin, Chia-Min; Wu, Fone-Mao; Kim, Hoi-Kyung; Doyle, Michael P; Michael, Barry S; Williams, L Keoki
2003-12-01
Compared with other parts of the hand, the area beneath fingernails harbors the most microorganisms and is most difficult to clean. Artificial fingernails, which are usually long and polished, reportedly harbor higher microbial populations than natural nails. Hence, the efficacy of different hand washing methods for removing microbes from natural and artificial fingernails was evaluated. Strains of nonpathogenic Escherichia coli JM109 and feline calicivirus (FCV) strain F9 were used as bacterial and viral indicators, respectively. Volunteers with artificial or natural nails were artificially contaminated with ground beef containing E. coli JM109 or artificial feces containing FCV. Volunteers washed their hands with tap water, regular liquid soap, antibacterial liquid soap, alcohol-based hand sanitizer gel, regular liquid soap followed by alcohol gel, or regular liquid soap plus a nailbrush. The greatest reduction of inoculated microbial populations was obtained by washing with liquid soap plus a nailbrush, and the least reduction was obtained by rubbing hands with alcohol gel. Lower but not significantly different (P > 0.05) reductions of E. coli and FCV counts were obtained from beneath artificial than from natural fingernails. However, significantly (P < or = 0.05) higher E. coli and FCV counts were recovered from hands with artificial nails than from natural nails before and after hand washing. In addition, microbial cell numbers were correlated with fingernail length, with greater numbers beneath fingernails with longer nails. These results indicate that best practices for fingernail sanitation of food handlers are to maintain short fingernails and scrub fingernails with soap and a nailbrush when washing hands.
UV-curable gel formulations: Potential drug carriers for the topical treatment of nail diseases.
Kerai, Laxmi Valji; Hilton, Stephen; Murdan, Sudaxshina
2015-08-15
Nail diseases are common, cause significant distress and treatments are far from successful. Our aim was to investigate the potential of UV-curable gels - currently used as cosmetics - as topical drug carriers for their treatment. These formulations have a long residence on the nail, which is expected to increase patient compliance and the success of topical therapy. The gels are composed of the diurethane dimethacrylate, ethyl methacrylate, 2-hydroxy-2-methylpropiophenone, an antifungal drug (amorolfine HCl or terbinafine HCl) and an organic liquid (ethanol or NMP) as drug solvent. Following its application to a substrate and exposure to a UVA lamp for 2 min, the gel polymerises and forms a smooth, glossy and amorphous film, with negligible levels of residual monomers. No drug-polymer interactions were found and drug loading did not affect the film's properties, such as thickness, crystallinity and transition temperatures. In contrast, the organic solvent did influence the film's properties; NMP-containing films had lower glass transition temperatures, adhesion and water resistance than ethanol-based ones. Water-resistance being a desired property, ethanol-based formulations were investigated further for stability, drug release and ungual permeation. The films were stable under accelerated stability testing conditions. Compared to terbinafine, amorolfine was released to a greater extent, had a higher ungual flux, but a lower concentration in the nailplate. However, both drugs were present at considerably high levels in the nail when their MICs are taken into account. We thus conclude that UV-curable gels are promising candidates as topical nail medicines. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
The influence of nail blocking conditions in cattle femoral fractures.
Paolucci, Leopoldo A; Las Casas, Estevam B; Faleiros, Rafael R; Paz, Cahuê F R; Rocha Junior, Sergio S
2018-05-07
To investigate the effect of different fixation strategies of the intramedullary interlocking nail (IIN) on the mechanical behavior of a polymeric implant applied for femoral fracture fixation in calves, and to evaluate the performance of a glass fiber-reinforced polymer applied in a bovine femoral fracture reduction system, five Holstein male animals with a mean weight (±SD) of 62.8 ± 20.4 kg and aged 74 ± 15 were used to generate biomechanical parameters for this study. Twelve models of the fractured bovine femur, simulating a simple oblique fracture, were developed for use during the simulations. The models were divided into three groups, with each group of four models being associated with a different fixation strategy. Models were used to simulate the loading conditions corresponding to a calf in the transition (decubitus position to static position) condition. The maximum stresses found in each set (bone/implant) were compared with the reference stresses of each nail material. Maximum implant stresses were found in the screws and at the interface between the screw and the nail. The performance of implants was influenced by the material and fixation strategy, which can be confirmed by the stress values found in the set. The analysis indicated that the composite nail is able to withstand the loading demands in all fixation strategies. The finite element analysis (FEA) demonstrated that all polymeric materials analyzed provided sufficient resistance to withstand the loading forces imposed to the femur when an adequate blocking strategy was applied. Copyright © 2018 Elsevier Ltd. All rights reserved.
Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence.
Fleming, David E B; Nader, Michel N; Foran, Kelly A; Groskopf, Craig; Reno, Michael C; Ware, Chris S; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J
2017-02-01
The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K α , selenium K α , arsenic K β , selenium K β , and bromine K α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K α peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. Copyright © 2016 Elsevier Ltd. All rights reserved.
Allergic contact dermatitis from acrylic nails in a flamenco guitarist.
Alcántara-Nicolás, F A; Pastor-Nieto, M A; Sánchez-Herreros, C; Pérez-Mesonero, R; Melgar-Molero, V; Ballano, A; De-Eusebio, E
2016-12-01
Acrylates are molecules that are well known for their strong sensitizing properties. Historically, many beauticians and individuals using store-bought artificial nail products have developed allergic contact dermatitis from acrylates. More recently, the use of acrylic nails among flamenco guitarists to strengthen their nails has become very popular. A 40-year-old non-atopic male patient working as a flamenco guitarist developed dystrophy, onycholysis and paronychia involving the first four nails of his right hand. The lesions were confined to the fingers where acrylic materials were used in order to strengthen his nails to play the guitar. He noticed improvement whenever he stopped using these materials and intense itching and worsening when he began reusing them. Patch tests were performed and positive results obtained with 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxyethyl acrylate (2-HEA), ethyleneglycol-dimethacrylate (EGDMA) and 2-hydroxypropyl methacrylate (2-HPMA). The patient was diagnosed with occupational allergic contact dermatitis likely caused by acrylic nails. Artificial nails can contain many kinds of acrylic monomers but most cases of contact dermatitis are induced by 2-HEMA, 2-HPMA and EGDMA. This is the first reported case of occupational allergic contact dermatitis from acrylates in artificial nails in a professional flamenco guitar player. Since the practice of self-applying acrylic nail products is becoming very popular within flamenco musicians, we believe that dermatology and occupational medicine specialists should be made aware of the potentially increasing risk of sensitization from acrylates in this setting. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
External lead contamination of women's nails by surma in Pakistan: Is the biomarker reliable?
Ikegami, Akihiko; Takagi, Mai; Fatmi, Zafar; Kobayashi, Yayoi; Ohtsu, Mayumi; Cui, Xiaoyi; Mise, Nathan; Mizuno, Atsuko; Sahito, Ambreen; Khoso, Aneeta; Kayama, Fujio
2016-11-01
Adverse health effects of heavy metals are a public health concern, especially lead may cause negative health impacts to human fetal and infantile development. The lead concentrations in Pakistani pregnant women's nails, used as a biomarker, were measured to estimate the lead exposure. Thirteen nail samples out of 84 nails analyzed contained lead higher than the concentration (13.6 μg/g) of the fatal lead poisoning case, raising the possibility of an external contamination. Eye cosmetics such as surma are recognized as one of the important sources of lead exposure in Pakistan. We collected in Pakistan 30 eye cosmetics made in Pakistan, Saudi Arabia and western countries. As the metal composition analysis by energy dispersive X-ray fluorescence spectrometry revealed that some surma samples contained lead more than 96%, the surma might contaminate the nail specimen. Scanning electron microscopy observations showed that lead-containing surma consists of fine particle of galena (ore of lead sulfide) in respirable dust range (less than 10 μm). In addition, relative in vitro bioavailability of lead in the surma was determined as 5.2%. Thus, lead-containing surma consists of inhalable and bioavailable particles, and it contributes an increased risk of lead exposure. Moreover, the relationship between the surma and the lead-contaminated nails by lead isotope ratios analysis indicated the potential of lead contamination in nails by surma. These results suggest that lead in the nails was derived both from body burden of lead and external contamination by lead-containing surma. Therefore, nail is not suited as a biomarker for lead exposure in the countries where surma used, because we may overestimate lead exposure by surface lead contamination in the nail by surma. Copyright © 2016 Elsevier Ltd. All rights reserved.
Karaarslan, A A; Acar, N
2018-02-01
Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.
Satam, Vijay; Babu, Balaji; Porte, Alexander; Savagian, Mia; Lee, Megan; Smeltzer, Thomas; Liu, Yang; Ramos, Joseph; Wilson, W David; Lin, Shicai; Kiakos, Kostantinos; Hartley, John A; Lee, Moses
2012-09-15
A novel diamino/dicationic polyamide f-Im(*)PyIm (5) that contains an orthogonally positioned aminopropyl chain on an imidazole (Im(*)) moiety was designed to target 5'-ACGCGT-3'. The DNA binding properties of the diamino polyamide 5, determined by CD, ΔT(M), DNase I footprinting, SPR, and ITC studies, were compared with those of its monoamino/monocationic counterpart f-ImPyIm (1) and its diamino/dicationic isomer f-ImPy(*)Im (2), which has the aminopropyl group attached to the central pyrrole unit (Py(*)). The results gave evidence for the minor groove binding and selectivity of polyamide 5 for the cognate sequence 5'-ACGCGT-3', and with strong affinity (K(eq)=2.3×10(7) M(-1)). However, the binding affinities varied according to the order: f-ImPy(*)Im (2)>f-ImPyIm (1)≥f-Im(*)PyIm (5) confirming that the second amino group can improve affinity, but its position within the polyamide can affect affinity. Copyright © 2012 Elsevier Ltd. All rights reserved.
Effect of vehicle and route of administration of letrozole on ovarian function in a bovine model.
Yapura, M J; Mapletoft, R J; Pierson, R A; Singh, J; Adams, G P
2014-10-01
The objective of this study was to determine the effects of vehicle and route of administration of letrozole on ovarian function in sexually mature beef heifers. On Day 3 (Day 0=ovulation), heifers were assigned randomly to four treatment groups and given 1mgkg(-1) letrozole intravenously (iv, n=10) or intramuscularly (im, n=10) or given a placebo iv (control iv, n=5) or im (control im, n=5). The interwave interval was longer in heifers treated with letrozole im than in im and iv controls (11.7±0.30 vs 9.5±0.50 and 10±0.43, respectively; P<0.05). Corpus luteum diameter profiles and plasma progesterone concentrations were greater (P<0.03 and P<0.05, respectively) in heifers treated with letrozole im compared with control im. Plasma oestradiol concentrations were lower in both letrozole-treated groups compared with controls (P≤0.03). Plasma LH concentrations tended to be elevated at the time of wave emergence in heifers treated with letrozole im compared with other groups (group-by-day interaction, P=0.06) and plasma FSH concentrations tended to be greater (P<0.09) in heifers treated with letrozole by either route compared with a single control group. We conclude that intramuscular administration of letrozole in oil is a feasible route and vehicle for the development of a letrozole-based treatment protocol for herd synchronisation in cattle.
Aging changes in hair and nails
... page: //medlineplus.gov/ency/article/004005.htm Aging changes in hair and nails To use the sharing ... you age, your hair and nails begin to change. HAIR CHANGES AND THEIR EFFECTS Hair color change . ...
Hu, Xue; Li, Li; Yu, Xinyi; Zhang, Ruyi; Yan, Shujuan; Zeng, Zongyue; Shu, Yi; Zhao, Chen; Wu, Xingye; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Yang, Chao; Wu, Ke; Wu, Ying; An, Liping; Huang, Shifeng; Ji, Xiaojuan; Gong, Cheng; Yuan, Chengfu; Zhang, Linghuan; Liu, Wei; Huang, Bo; Feng, Yixiao; Zhang, Bo; Haydon, Rex C; Luu, Hue H; Reid, Russell R; Lee, Michael J; Wolf, Jennifer Moriatis; Yu, Zebo; He, Tong-Chuan
2017-12-19
Mesenchymal stem cells (MSCs) are multipotent non-hematopoietic progenitor cells that can undergo self-renewal and differentiate into multi-lineages. Bone marrow stromal stem cells (BMSCs) represent one of the most commonly-used MSCs. In order to overcome the technical challenge of maintaining primary BMSCs in long-term culture, here we seek to establish reversibly immortalized mouse BMSCs (imBMSCs). By exploiting CRISPR/Cas9-based homology-directed-repair (HDR) mechanism, we target SV40T to mouse Rosa26 locus and efficiently immortalize mouse BMSCs (i.e., imBMSCs). We also immortalize BMSCs with retroviral vector SSR #41 and establish imBMSC41 as a control line. Both imBMSCs and imBMSC41 exhibit long-term proliferative capability although imBMSC41 cells have a higher proliferation rate. SV40T mRNA expression is 130% higher in imBMSC41 than that in imBMSCs. However, FLP expression leads to 86% reduction of SV40T expression in imBMSCs, compared with 63% in imBMSC41 cells. Quantitative genomic PCR analysis indicates that the average copy number of SV40T and hygromycin is 1.05 for imBMSCs and 2.07 for imBMSC41, respectively. Moreover, FLP expression removes 92% of SV40T in imBMSCs at the genome DNA level, compared with 58% of that in imBMSC41 cells, indicating CRISPR/Cas9 HDR-mediated immortalization of BMSCs can be more effectively reversed than that of retrovirus-mediated random integrations. Nonetheless, both imBMSCs and imBMSC41 lines express MSC markers and are highly responsive to BMP9-induced osteogenic, chondrogenic and adipogenic differentiation in vitro and in vivo . Thus, the engineered imBMSCs can be used as a promising alternative source of primary MSCs for basic and translational research in the fields of MSC biology and regenerative medicine.
Hu, Xue; Li, Li; Yu, Xinyi; Zhang, Ruyi; Yan, Shujuan; Zeng, Zongyue; Shu, Yi; Zhao, Chen; Wu, Xingye; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Yang, Chao; Wu, Ke; Wu, Ying; An, Liping; Huang, Shifeng; Ji, Xiaojuan; Gong, Cheng; Yuan, Chengfu; Zhang, Linghuan; Liu, Wei; Huang, Bo; Feng, Yixiao; Zhang, Bo; Haydon, Rex C.; Luu, Hue H.; Reid, Russell R.; Lee, Michael J.; Wolf, Jennifer Moriatis; Yu, Zebo; He, Tong-Chuan
2017-01-01
Mesenchymal stem cells (MSCs) are multipotent non-hematopoietic progenitor cells that can undergo self-renewal and differentiate into multi-lineages. Bone marrow stromal stem cells (BMSCs) represent one of the most commonly-used MSCs. In order to overcome the technical challenge of maintaining primary BMSCs in long-term culture, here we seek to establish reversibly immortalized mouse BMSCs (imBMSCs). By exploiting CRISPR/Cas9-based homology-directed-repair (HDR) mechanism, we target SV40T to mouse Rosa26 locus and efficiently immortalize mouse BMSCs (i.e., imBMSCs). We also immortalize BMSCs with retroviral vector SSR #41 and establish imBMSC41 as a control line. Both imBMSCs and imBMSC41 exhibit long-term proliferative capability although imBMSC41 cells have a higher proliferation rate. SV40T mRNA expression is 130% higher in imBMSC41 than that in imBMSCs. However, FLP expression leads to 86% reduction of SV40T expression in imBMSCs, compared with 63% in imBMSC41 cells. Quantitative genomic PCR analysis indicates that the average copy number of SV40T and hygromycin is 1.05 for imBMSCs and 2.07 for imBMSC41, respectively. Moreover, FLP expression removes 92% of SV40T in imBMSCs at the genome DNA level, compared with 58% of that in imBMSC41 cells, indicating CRISPR/Cas9 HDR-mediated immortalization of BMSCs can be more effectively reversed than that of retrovirus-mediated random integrations. Nonetheless, both imBMSCs and imBMSC41 lines express MSC markers and are highly responsive to BMP9-induced osteogenic, chondrogenic and adipogenic differentiation in vitro and in vivo. Thus, the engineered imBMSCs can be used as a promising alternative source of primary MSCs for basic and translational research in the fields of MSC biology and regenerative medicine. PMID:29340096
A fatal nail gun injury--an unusual ricochet?
Nadesan, K
2000-01-01
An 18-year-old construction worker suddenly collapsed while handling a power-actuated nail gun and died shortly after. A neat, almost circular puncture wound was found on the front of his left chest. No fire-arm residues were detected on the surrounding skin. The police stated that it was an accidental injury, at a construction site, where a nail fired from a nail gun by the deceased had deflected off the wall and struck him on the front of the chest. Since the entry wound appeared to be a neat hole, and that too on the front of the left chest overlying the heart area, there was reluctance on the part of the pathologist to accept it as an accidental injury due to a ricochet. A visit to the scene, interrogation of witnesses, examination of the alleged tool and post-mortem X-ray of the deceased were undertaken prior to autopsy. A bent nail was found in the heart. The scene visit and the subsequent autopsy revealed that the nail took a roughly circular flightpath after it had struck the wall, all the while travelling with its pointed end directed forward. Within the body too, the nail maintained the same path. Various medicolegal issues are discussed pertaining to nail-gun injuries. The importance of a visit to the scene, examination of the alleged tool, interrogation of witnesses and the X-ray of the body, all prior to autopsy, are emphasized. The conclusion was: accidental death due to the unusual ricochet of a nail.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yanan, E-mail: ynzhang@suda.edu.cn; Ren, Weiqing, E-mail: matrw@nus.edu.sg; Institute of High Performance Computing, Singapore 138632
2014-12-28
Droplets on a solid surface patterned with microstructures can exhibit the composite Cassie-Baxter (CB) state or the wetted Wenzel state. The stability of the CB state is determined by the energy barrier separating it from the wetted state. In this work, we study the CB to Wenzel transition using the string method [E et al., J. Chem. Phys. 126, 164103 (2007); W. Ren and E. Vanden-Eijnden, J. Chem. Phys. 138, 134105 (2013)]. We compute the transition states and energy barriers for a three-dimensional droplet on patterned surfaces. The liquid-vapor coexistence is modeled using the mean field theory. Numerical results aremore » obtained for surfaces patterned with straight pillars and nails, respectively. It is found that on both type of surfaces, wetting occurs via infiltration of the liquid in a single groove. The reentrant geometry of nails creates large energy barrier for the wetting of the solid surface compared to straight pillars. We also study the effect of surface chemistry, pillar height, and inter-pillar spacing on the energy barrier and compare it with nails.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-24
... steel nails: (1) Non-collated (i.e., hand-driven or bulk), two-piece steel nails having plastic or steel...-collated (i.e., hand-driven or bulk), steel nails having a bright or galvanized finish, a smooth, barbed or... actual head diameter of 0.3375'' to 0.500'', inclusive; and (4) Non-collated (i.e., hand-driven or bulk...
Sarcoidosis: nail dystrophy without underlying bone changes.
Wakelin, S H; James, M P
1995-06-01
Sarcoidosis is a chronic granulomatous disease of unknown origin that affects multiple organs and may present with a variety of skin lesions. Involvement of the nails is rare and almost invariably associated with underlying bone disease. We describe a patient with sarcoid nail dystrophy in whom this diagnosis was confirmed by a proximal nail fold biopsy. Radiologic investigation did not show evidence of an associated bone dystrophy in this case.
Morawska-Chochół, Anna; Chłopek, Jan; Szaraniec, Barbara; Domalik-Pyzik, Patrycja; Balacha, Ewa; Boguń, Maciej; Kucharski, Rafael
2015-06-01
When it comes to the treatment of long bone fractures, scientists are still investigating new materials for intramedullary nails and different manufacturing methods. Some of the most promising materials used in the field are resorbable polymers and their composites, especially since there is a wide range of potential manufacturing and processing methods. The aim of this work was to select the best manufacturing method and technological parameters to obtain multiphase, and multifunctional, biodegradable intramedullary nails. All composites were based on a poly(l-lactide) matrix. Either magnesium alloy wires or carbon and alginate fibres were introduced in order to reinforce the nails. The polylactide matrix was also modified with tricalcium phosphate and gentamicin sulfate. The composite nails were manufactured using three different methods: forming from solution, injection moulding and hot pressing. The effect of each method of manufacturing on mechanical properties and degradation rate of the nails was evaluated. The study showed that injection moulding provides higher uniformity and homogeneity of the particle-modified polylactide matrix, whereas hot pressing favours applying higher volume fractions of fibres and their better impregnation with the polymer matrix. Thus, it was concluded that the fabrication method should be individually selected dependently on the nail's desired phase composition. Copyright © 2015 Elsevier B.V. All rights reserved.
Zaias, N; Escovar, S X; Rebell, G
2014-08-01
Opportunistic onychomycosis is defined, when a non-dermatophyte mould is cultured from an abnormal nail unit in the absence of a dermatophyte. The presumption is that the mould has caused the abnormal clinical appearance of the nail unit, yet there are no data available to substantiate this claim. Reports have only identified the mould being recovered from the nail unit niche. A review of the published dermatologic literature describing toenail opportunistic onychomycosis by non-dermatophyte fungi has shown toenails with onycholysis, nail bed (NB) keratosis and nail plate surface abnormalities. The appearance of these clinical changes is indistinguishable from the diagnosis of the Asymmetric Gait Nail Unit Signs (AGNUS). AGNUS is produced by the friction of the closed shoe in patients with an asymmetric gait, resulting primarily from the ubiquitous uneven flat feet. Most commonly, species of Acremonium (Cephalosporium), Aspergillus, Fusarium, Scopulariopsis and rarely species of many different fungi genera are capable of surviving and reproducing in a keratinous environment and change the clinical appearance of the involved nail unit. AGNUS toenails predispose to the colonization by the non-dermatophyte opportunistic fungi but not by dermatophyte fungi. © 2014 European Academy of Dermatology and Venereology.
Application of Soil Nailing Technique for Protection and Preservation Historical Buildings
NASA Astrophysics Data System (ADS)
Kulczykowski, Marek; Przewłócki, Jarosław; Konarzewska, Bogusława
2017-10-01
Soil nailing is one of the recent in situ techniques used for soil improvement and in stabilizing slopes. The process of soil nailing consists of reinforcing the natural ground with relatively small steel bars or metal rods, grouted in the pre-drilled holes. This method has a wide range of applications for stabilizing deep excavations and steep slopes. Soil nailing has recently become a very common method of slope stabilisation especially where situated beneath or adjacent to historical buildings. Stabilisation by nails drilled into existing masonry structures such as failing retaining walls abutments, provide long term stability without demolition and rebuilding costs. Two cases of soil nailing technology aimed at stabilising slopes beneath old buildings in Poland are presented in this paper. The first concerns application of this technology to repair a retaining wall supporting the base of the dam at the historic hydroelectric power plant in Rutki. The second regards a concept of improving the slope of the Castle Hill in Sandomierz. An analysis of the slope stability for the latter case, using stabilisation technique with the piling system and soil nailing was performed. Some advantages of soil nailing especially for protection of historical buildings, are also underlined. And, the main results of an economic comparison analysis are additionally presented.
Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar
2011-06-01
Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rankine, Leith; Wan, Hanlin; Parikh, Parag
Purpose: To demonstrate that fiducial tracking during pretreatment Cone-Beam CT (CBCT) can accurately measure tumor motion and that this method should be used to validate 4-dimensional CT (4DCT) margins before each treatment fraction. Methods and Materials: For 31 patients with abdominal tumors and implanted fiducial markers, tumor motion was measured daily with CBCT and fluoroscopy for 202 treatment fractions. Fiducial tracking and maximum-likelihood algorithms extracted 3-dimensional fiducial trajectories from CBCT projections. The daily internal margin (IM) (ie, range of fiducial motion) was calculated for CBCT and fluoroscopy as the 5th-95th percentiles of displacement in each cardinal direction. The planning IMmore » from simulation 4DCT (IM{sub 4DCT}) was considered adequate when within ±1.2 mm (anterior–posterior, left–right) and ±3 mm (superior–inferior) of the daily measured IM. We validated CBCT fiducial tracking as an accurate predictive measure of intrafraction motion by comparing the daily measured IM{sub CBCT} with the daily IM measured by pretreatment fluoroscopy (IM{sub pre-fluoro}); these were compared with pre- and posttreatment fluoroscopy (IM{sub fluoro}) to identify those patients who could benefit from imaging during treatment. Results: Four-dimensional CT could not accurately predict intrafractional tumor motion for ≥80% of fractions in 94% (IM{sub CBCT}), 97% (IM{sub pre-fluoro}), and 100% (IM{sub fluoro}) of patients. The IM{sub CBCT} was significantly closer to IM{sub pre-fluoro} than IM{sub 4DCT} (P<.01). For patients with median treatment time t < 7.5 minutes, IM{sub CBCT} was in agreement with IM{sub fluoro} for 93% of fractions (superior–inferior), compared with 63% for the t > 7.5 minutes group, demonstrating the need for patient-specific intratreatment imaging. Conclusions: Tumor motion determined from 4DCT simulation does not accurately predict the daily motion observed on CBCT or fluoroscopy. Cone-beam CT could replace fluoroscopy for pretreatment verification of simulation IM{sub 4DCT}, reducing patient setup time and imaging dose. Patients with treatment time t > 7.5 minutes could benefit from the addition of intratreatment imaging.« less
Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.
Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S
1979-01-01
The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.
Managing Chemotherapy Side Effects: Skin and Nail Changes
... ational C ancer I nstitute Managing Chemotherapy Side Effects Skin and Nail Changes “I was glad to ... services national institutes of health Managing Chemotherapy Side Effects: Skin and Nail Changes Protect your skin from ...
2017-08-17
the peak serum concentration of TXA when comparing IV and IM administration, IM did reach a minimum concentration which in vitro has been shown to... research is needed to determine the efficacy of TXA given by this route. 200 ::J’ .€ 150 g> .§_ c: 0 1a ...... "E ~ 100 c: 0 u ~ c: ca...serum concentration of TXA when comparing IV and IM administration, IM did reach a minimum concentration which in vitro has been shown to inhibit
NASA Astrophysics Data System (ADS)
Haler, Jean R. N.; Massonnet, Philippe; Chirot, Fabien; Kune, Christopher; Comby-Zerbino, Clothilde; Jordens, Jan; Honing, Maarten; Mengerink, Ynze; Far, Johann; Dugourd, Philippe; De Pauw, Edwin
2018-01-01
Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. [Figure not available: see fulltext.
Wichita fusion nail for patients with failed total knee arthroplasty and active infection.
Barsoum, Wael K; Hogg, Christopher; Krebs, Viktor; Klika, Alison K
2008-01-01
In the study reported here, we retrospectively evaluated short-term results of knee arthrodesis using the Wichita fusion nail (WFN) in patients with active infection. Clinical examinations, x-rays, time to union, knee pain after fusion, and ambulatory status were compared in 7 patients who received the WFN. Mean fusion rate was 86%, mean time to fusion was 9.8 months, and mean complication rate was 57%. Complication rates were high, but clinical outcomes were acceptable, supporting use of WFN as a reasonable way to salvage failed total knee arthroplasty in patients with active infection.
Huang, Peng; Tang, Peifu; Yao, Qi
2007-11-01
To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures. From October 2003 to April 2006, 55 patients with tibial diaphysis fractures (58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirty-four fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days (LCP group). The operation time, the range of motion of knee and ankle joints, fracture healing time, and complications were evaluated. The patients were followed up 8-26 months (13 months on average). The operation time was 84.0+/-9.2 min (intramedullary nailing group) and 69.0+/-8.4 min (LCP group); the average cost in hospital was yen 19,297.78 in the intramedullary nailing group and yen 14,116.55 in the LCP group respectively, showing significant differences (P < 0.05). The flexion and extension of knee joint was 139.0 +/- 3.7 degrees and 4.0 +/- 0.7 degrees in intramedullary nailing group and 149.0+/-4.2 degrees and 0+/-0.4 degrees in LCP group, showing no significant difference (P>0.05). The doral flexion and plantar flexion of ankle joint were 13.0+/-1.7 degrees and 41.0+/-2.6 degrees in intramedullary nailing group, and 10.0+/-1.4 degrees and 44.0+/-2.3 degrees in LCP group, showing no significant differences (P>0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3. 1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing end trouble in 3 cases in intramedullary nailing group; moreover rotation deformity occurred 1 case and anterior knee pain occurred in 6 cases (17.1%). One angulation and open fracture developed osteomyelitis in 1 case 1 week postoperatively and angulation deformity occurred in 1 case of distal-third tibial fractures in LCP group. LCP and locked intramedullary nailing can achieve satisfactory results in treating tibial diaphysis fracture LCP has advantages in less complication, operation time and cost in hospital.
The effect of retained intramedullary nails on tibial bone mineral density.
Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A
2008-07-01
Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.
A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems.
Lowe, Brian D; Albers, James; Hudock, Stephen D
2014-09-01
A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then "bumps" the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2-8% (horizontal nailing) and 9-20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user's perception of muscular effort.
A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems
Lowe, Brian D.; Albers, James; Hudock, Stephen D.
2015-01-01
A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then “bumps” the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2–8% (horizontal nailing) and 9–20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user’s perception of muscular effort. PMID:26321780
Huang, Yihong; Feng, Saran; Xu, Yujie; Chen, Wanru; Wang, Shuhua; Li, Depeng; Li, Zhenyu; Lu, Qunxian; Pan, Xiuying; Xu, Kailin
2015-05-01
The effect of infusion of lentiviral vector‑mediated, genetically engineered dendritic cells (DCs) following allogeneic bone marrow transplantation (allo‑BMT) on graft‑versus‑host disease (GVHD) and graft‑versus‑leukemia (GVL) was investigated in a mouse model. Lentivirus‑mediated expression of soluble tumor necrosis factor receptor 1 (sTNFR1) converted immature DCs (imDCs) from BABL/c mice into engineered DCs in vitro. An EL4 leukemia allo‑BMT model of BABL/c to C57BL/6 mice was established. Engineered DCs with donor bone marrow cells and splenocytes were subsequently transplanted into myeloablatively irradiated recipients. The average survival duration in the sTNFR1‑ and pXZ9‑imDC groups was significantly prolonged compared with that of the allo‑BMT group (P<0.05). Mild histological changes in GVHD or leukemia were observed in the recipients in the sTNFR1‑imDC group and clinical GVHD scores in this group were significantly decreased compared with those of the transplantation and pXZ9‑imDC groups. Serum interferon‑γ levels were decreased in the pXZ9‑imDC and sTNFR1‑imDC groups compared with those in the allo‑BMT group (P<0.05), with the reduction being more significant in the sTNFR1‑imDC group (P<0.05). Serum interleukin‑4 expression levels were decreased in the allo‑BMT group, but gradually increased in the pXZ9‑imDC and sTNFR1‑imDC groups (P<0.05). Co‑injection of donor genetically‑engineered imDCs was able to efficiently protect recipient mice from lethal GVHD while preserving GVL effects during allo‑BMT.
Coexistence of nail lichen planus and lichen planus pigmentosus.
Lemes, Luciana Rodino; Verde, Renata Brandão Villa; Durães, Sandra Maria Barbosa; Araripe, Adolpho de Alencar; Pantaleão, Luciana
2016-01-01
We describe a fifty-six-year old, Afro-descendent female patient showing dystrophy of her twenty nails and hyperchromic, asymptomatic macule on her face. Histopathological examination of the macule showed vacuolization of the basal layer, melanophages in the superficial dermis and lymphoplasmocytic inflammatory infiltrate. Nail biopsy revealed orthokeratotic hyperkeratosis and lichenoid inflammatory infiltrate. Lichen planus pigmentosus is an uncommon variety of lichen planus. It is characterized by typical hyperpigmented macules on the face and neck. Nail changes might be present in 10% of lichen planus cases, but no associations with lichen planus pigmentosus have been described. We report a case of lichen planus in twenty nails associated with lichen planus pigmentosus on the patient's face.
Is Marathon Training Harder than the Ironman Training? An ECO-method Comparison.
Esteve-Lanao, Jonathan; Moreno-Pérez, Diego; Cardona, Claudia A; Larumbe-Zabala, Eneko; Muñoz, Iker; Sellés, Sergio; Cejuela, Roberto
2017-01-01
Purpose: To compare the absolute and relative training load of the Marathon (42k) and the Ironman (IM) training in recreational trained athletes. Methods: Fifteen Marathoners and Fifteen Triathletes participated in the study. Their performance level was the same relative to the sex's absolute winner at the race. No differences were presented neither in age, nor in body weight, height, BMI, running VO 2max max, or endurance training experience ( p > 0.05). They all trained systematically for their respective event (IM or 42k). Daily training load was recorded in a training log, and the last 16 weeks were compared. Before this, gas exchange and lactate metabolic tests were conducted in order to set individual training zones. The Objective Load Scale (ECOs) training load quantification method was applied. Differences between IM and 42k athletes' outcomes were assessed using Student's test and significance level was set at p < 0.05. Results: As expected, Competition Time was significantly different (IM 11 h 45 min ± 1 h 54 min vs. 42k 3 h 6 min ± 28 min, p < 0.001). Similarly, Training Weekly Avg Time (IM 12.9 h ± 2.6 vs. 42k 5.2 ± 0.9), and Average Weekly ECOs (IM 834 ± 171 vs. 42k 526 ± 118) were significantly higher in IM ( p < 0.001). However, the Ratio between Training Load and Training Time was superior for 42k runners when comparing ECOs (IM 65.8 ± 11.8 vs. 42k 99.3 ± 6.8) ( p < 0.001). Finally, all ratios between training time or load vs. Competition Time were superior for 42k ( p < 0.001) (Training Time/Race Time: IM 1.1 ± 0.3 vs. 42k 1.7 ± 0.5), (ECOs Training Load/Race Time: IM 1.2 ± 0.3 vs. 42k 2.9 ± 1.0). Conclusions: In spite of IM athletes' superior training time and total or weekly training load, when comparing the ratios between training load and training time, and training time or training load vs. competition time, the preparation of a 42k showed to be harder.
Is Marathon Training Harder than the Ironman Training? An ECO-method Comparison
Esteve-Lanao, Jonathan; Moreno-Pérez, Diego; Cardona, Claudia A.; Larumbe-Zabala, Eneko; Muñoz, Iker; Sellés, Sergio; Cejuela, Roberto
2017-01-01
Purpose: To compare the absolute and relative training load of the Marathon (42k) and the Ironman (IM) training in recreational trained athletes. Methods: Fifteen Marathoners and Fifteen Triathletes participated in the study. Their performance level was the same relative to the sex's absolute winner at the race. No differences were presented neither in age, nor in body weight, height, BMI, running VO2max max, or endurance training experience (p > 0.05). They all trained systematically for their respective event (IM or 42k). Daily training load was recorded in a training log, and the last 16 weeks were compared. Before this, gas exchange and lactate metabolic tests were conducted in order to set individual training zones. The Objective Load Scale (ECOs) training load quantification method was applied. Differences between IM and 42k athletes' outcomes were assessed using Student's test and significance level was set at p < 0.05. Results: As expected, Competition Time was significantly different (IM 11 h 45 min ± 1 h 54 min vs. 42k 3 h 6 min ± 28 min, p < 0.001). Similarly, Training Weekly Avg Time (IM 12.9 h ± 2.6 vs. 42k 5.2 ± 0.9), and Average Weekly ECOs (IM 834 ± 171 vs. 42k 526 ± 118) were significantly higher in IM (p < 0.001). However, the Ratio between Training Load and Training Time was superior for 42k runners when comparing ECOs (IM 65.8 ± 11.8 vs. 42k 99.3 ± 6.8) (p < 0.001). Finally, all ratios between training time or load vs. Competition Time were superior for 42k (p < 0.001) (Training Time/Race Time: IM 1.1 ± 0.3 vs. 42k 1.7 ± 0.5), (ECOs Training Load/Race Time: IM 1.2 ± 0.3 vs. 42k 2.9 ± 1.0). Conclusions: In spite of IM athletes' superior training time and total or weekly training load, when comparing the ratios between training load and training time, and training time or training load vs. competition time, the preparation of a 42k showed to be harder. PMID:28611674
Uziel, Liad
2014-06-01
This article explores the status of impression management (IM) scales ("lie scales," notably, BIDR-IM) as measures of response bias, offers theory-driven substantive meaning to them, and compares them with self-deception enhancement (SDE). Study 1 (N = 99) compared self-descriptions of actual self and ideal self given in a non-anonymous setting. High similarity indicates self-enhancement. Study 2 (70 dyads) analyzed self-other agreement about IM and SDE. Agreement indicates substantive basis to the scales' scores. Study 3 (N = 182) explored the centrality of self-control in the self-perception of individuals varying in IM and SDE. Study 4 (95 dyads) corroborated self-reports about self-control using informants' reports. In Study 1, IM was associated with relative humility, whereas SDE was associated with self-enhancement. In Study 2, strong self-other agreement was found only for IM, indicating that high IM (but not SDE) is grounded in real-life behavior. In Study 3, self-control was central in the self-perception of high IM and high SDE individuals. In Study 4, strong relations with self-control were corroborated by informants only for IM. IM scales measure substantive content associated with self-control aimed at social adaptation, whereas the SDE scale depicts individuals with a grandiose self-perception, who fail to impress knowledgeable others. © 2013 Wiley Periodicals, Inc.
Boonyasirikool, Chinnakart; Tanakeatsakul, Sakkarin; Niempoog, Sunyarn
2015-04-01
The optimal fixation of metacarpal fracture should provide sufficient stability to permit early functionfor all types of fracture. However; it must preserve surrounding soft tissue during application and not require secondary removal due to its prominence. The prototype of metacarpal locked intramedullary nail (MCLN) was designed by our institute aiming to achieve those allfeatures. To biomechanically test our newly designed, locked metacarpal nail and compare with common current available fixation methods. Thirty chicken humeri were devided into 3 groups (n = 1 per group) according tofixation techniques: MCLN, 1.5 mm miniplate (Synthes), and Kirschner wire. After complete fixation, all specimens were osteotomized at mid-shaft creating transverse fractures. Five specimens from each group were tested by load of failure under axial compression, and another five under bending force. In axial compression model, the loads tofailure in MCLN group was greatest (460 ± 17 N), which was significant higher than the Kirschner wire group. The MCLN group also showed the highest load to failure in bending test (341 ± 10 N). This value reaches statistical significance when compared with plate and Kirschner wire groups. The MCLN construct provided higher stability than miniplate and Kirschner wire fixation both in axial and bending mode. Together with the minimally invasive and soft tissue-friendly design concept, this study suggests that MCLN is promising fixation option for metacarpal fracture.
Thomas, A E; Guyver, P M; Taylor, J M; Czipri, M; Talbot, N J; Sharpe, I T
2015-09-01
Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems. This study reports the elective results of combined subtalar and ankle arthrodesis using one design of retrograde intramedullary compression nail. Retrospective review identified 58 patients undergoing 59 tibiotalocalcaneal arthrodesis procedures. Mean follow up was 9.15 (3-36) months with average age 60.7 (22-89) years. A function and subjective patient satisfaction questionnaire was achieved in 89%. 53 patients (93%) achieved union at a mean time of 4.17 months. Four patients (8%) subjectively thought the procedure was of no benefit while 42 (84%) had an excellent or good result. The mean visual analogue scale (VAS) score for preoperative functional pain was 7.46 compared to 1.98 post-operatively (p<0.001). This device and technique offers an effective treatment of hindfoot pathology giving reliable compression and subsequent fusion with excellent patient satisfaction and pain relief. IV case series. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Analysis of human nails by laser-induced breakdown spectroscopy
NASA Astrophysics Data System (ADS)
Hosseinimakarem, Zahra; Tavassoli, Seyed Hassan
2011-05-01
Laser-induced breakdown spectroscopy (LIBS) is applied to analyze human fingernails using nanosecond laser pulses. Measurements on 45 nail samples are carried out and 14 key species are identified. The elements detected with the present system are: Al, C, Ca, Fe, H, K, Mg, N, Na, O, Si, Sr, Ti as well as CN molecule. Sixty three emission lines have been identified in the spectrum that are dominated by calcium lines. A discriminant function analysis is used to discriminate among different genders and age groups. This analysis demonstrates efficient discrimination among these groups. The mean concentration of each element is compared between different groups. Correlation between concentrations of elements in fingernails is calculated. A strong correlation is found between sodium and potassium while calcium and magnesium levels are inversely correlated. A case report on high levels of sodium and potassium in patients with hyperthyroidism is presented. It is shown that LIBS could be a promising technique for the analysis of nails and therefore identification of health problems.
Tsang, S T J; Mills, L A; Frantzias, J; Baren, J P; Keating, J F; Simpson, A H R W
2016-04-01
The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p < 0.001), were predictive for failure of exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p < 0.001). Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. ©2016 The British Editorial Society of Bone & Joint Surgery.
Nail gun injuries among construction workers.
Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas
2003-05-01
Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data suggest that approximately 69 percent of puncture injuries may be due to an inadvertent gun discharge or misfire, preventable in large part by the use of sequential triggers. Worker training and education also are important components of nail gun injury prevention.
How was the Turin Shroud Man crucified?
Bevilacqua, M; Fanti, G; D'Arienzo, M; Porzionato, A; Macchi, V; De Caro, R
2014-12-01
As the literature is not exhaustive with reference to the way the Turin Shroud (TS) Man was crucified, and it is not easy to draw significant information from only a "photograph" of a man on a linen sheet, this study tries to add some detail on this issue based on both image processing of high resolution photos of the TS and on experimental tests on arms and legs of human cadavers. With regard to the TS Man hands, a first hypothesis states that the left hand of the TS Man was nailed twice at two different anatomical sites: the midcarpal joint medially to the pisiform between the lunate/pyramidal and capitate/uncinate bones (Destot's space) and the radiocarpal joint between the radio, lunate and scaphoid; also the right hand would have been nailed twice. A second hypothesis, preferred by the authors, states that the hands were nailed only once in the Destot's space with partial lesion of the ulnar nerve and flexion of the metacarpophalangeal joint of the thumbs. With regard to the TS Man feet, the imprint of the sole of the right foot leads to the conclusion that TS Man suffered a dislocation at the ankle just before the nailing. The entrance hole of the nail on the right foot is a few inches from the ankle, and excludes a double nailing. The nail has been driven between the tarsal bones. The TS Man suffered the following tortures during crucifixion: a very serious and widespread causalgia due to total paralysis of the upper right limb (paradoxical causalgia); a nailing of the left wrist with damage to the ulnar nerve; a similar nailing of the right wrist; and a nailing to both feet using one only nail that injured the plantaris medialis nerves. The respiratory limitation was probably not sufficient to cause death by asphyxiation. Also considering the hypovolemia produced by scourging and the many other tortures detectable on the TS, the principal cause of death can be attributed to a myocardial infarction. Copyright © 2014 Elsevier Ltd. All rights reserved.
Boutaud, B; Laville, J-M
2004-06-01
Elastic sliding centromedullary nailing (ESCN) proposed by Métaizeau in 1987 for the prevention and treatment of limb fractures in osteogenesis imperfecta has never been evaluated. A multicentric serie was studied in order to evaluate results of these procedure. Thirty-six ESCN procedures were performed in fourteen patients. Percutaneous pinning was used for the femur and distal tibia and arthrotomy for the distal femur as needed and in all cases for the proximal tibia. The pins were bent in compliance with the principles of the ESCN system. The ends of the pins were bent back to form a U pushed into the epiphysis. Reaxing osteotomies required minimal incisions. Age at the first procedure, the number of procedures and complications, and time between procedures were recorded. Pin overlap and the angle formed were also recorded. Pin gliding was evaluated. Ability to walk with or without assistance was noted. The medullary canal measured 4 to 10 mm. The first procedure was performed at a mean age of four years (range 15 days to 10 years). Follow-up was eight years (range 1-12). There were 2.5 procedures per patient (range 1-5). Pins had to be changed in 75% of the bone segments. Mean time between two procedures was 3.2 years. There were no cases of defective sliding or infection. There were four cases of secondary fracture with a mean 30% pin overlap, two pin migrations, one nonunion, and one shortening. The majority of the complications occurred after the age of five years. At last follow-up, three patients could not walk, four walked with aids, and eight without aids. The advantages of the technique (size of the pins, nailing without reaming, pin sliding in all cases, low cost) must not overshadow the drawbacks (risk of pin deformation and migration, secondary fracture). Secondary fractures might be limited by discrete valgus of the femoral shaft and preventive pin change when the angle formed approaches 30 degrees and when there is only 30% overlap left. Use of telescopic nails before the age of five years increases the risk of complications while most of the complications observed with ESCN occur after the age of five years. Twenty-five percent of the ESCN complications involved only the femur. The percent of secondary fractures was less than with telescopic nailing (3.6% versus 11%) but there were more cases of nail migration. All pins slid, compared with 6% failure of elongation with telescopic nails. Although proof is not available, surgical treatment of osteogenesis imperfecta before the age of five years appears to provide more rapid functional progress. Sliding centromedulary nailing is an attractive alternative before the age of five years. In older children and to the end of growth, telescopic nail or pinning should be discussed although pinning may permit more secondary fractures which can be limited by rigorous surveillance of pin position.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
... Gun Nail Manufacture Co., Ltd.; 126) Tianjin Xiantong Juxiang Metal MFG Co., Ltd.; 127) Tianjin...., Ltd.; 110) Tianjin Xiantong Fucheng Gun Nail Manufacture Co., Ltd.; 111) Tianjin Xiantong Juxiang...
Use of flexible facing for soil nail walls.
DOT National Transportation Integrated Search
2011-11-01
Soil nail walls are a widely used technology for retaining vertical and nearly vertical cuts in soil. A : significant portion of the cost of soil nail wall construction is related to the construction of a reinforced : concrete face. The potential for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakata, Kouhei; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp
Purpose: This study was designed to compare the strength among bone marrow nails created to treat long bone fractures using interventional procedures. Methods: Twelve resected intact tibiae of healthy swine were used. A circumferential bone fracture was made in nine tibiae and restored with the following created bone marrow nails: acrylic cement alone (ACA) (n = 3), acrylic-cement-filled bare metallic stent (AC-FBMS) (n = 3), and acrylic-cement-filled covered metallic (AC-FCMS) stent (n = 3). The remaining intact tibiae (n = 3) were used as controls. Results: A bone marrow nail was successfully achieved within 30 min in all swine. Themore » maximum injection volume of acrylic cement for creating ACA, AC-FBMS, and AC-FCMS was 1.7 {+-} 0.3, 3.2 {+-} 0.4, and 2.9 {+-} 0.4 mL, respectively. The thickness of bone marrow nail created in the ACA, AC-FBMS, and AC-FCMS groups was 3.6 {+-} 1.0, 10.3 {+-} 0.26, and 9.6 {+-} 0.32 mm, respectively (AC-FBMS group versus AC-FCMS group, p = 0.038), probably because of leakage of acrylic cement surrounding the interstices. The maximum bending power (kilonewton) and bending strength (newton/mm{sup 2}) in the normal long bone, ACA, AC-FBMS, and AC-FCMS groups were: 1.70 {+-} 0.25 and 79.2 {+-} 16.1; 0.21 {+-} 0.11 and 8.8 {+-} 2.8; 0.46 {+-} 0.06 and 18.2 {+-} 1.6; and 0.18 {+-} 0.04 and 7.8 {+-} 2.7, respectively. Conclusions: Although the maximum bending power and bending strength of AC-FBMS were not satisfactory, it was the most robust of the three marrow nails for restoring fractured long bone.« less
Chraim, M; Krenn, S; Alrabai, H M; Trnka, H-J; Bock, P
2018-02-01
Hindfoot arthrodesis with retrograde intramedullary nailing has been described as a surgical strategy to reconstruct deformities of the ankle and hindfoot in patients with Charcot arthropathy. This study presents case series of Charcot arthropathy patients treated with two different retrograde intramedullary straight compression nails in order to reconstruct the hindfoot and assess the results over a mid-term follow-up. We performed a retrospective analysis of 18 consecutive patients and 19 operated feet with Charcot arthropathy who underwent a hindfoot arthrodesis using a retrograde intramedullary compression nail. Patients were ten men and eight women with a mean age of 63.43 years (38.5 to 79.8). We report the rate of limb salvage, complications requiring additional surgery, and fusion rate in both groups. The mean duration of follow-up was 46.36 months (37 to 70). The limb salvage rate was 16 of 19 limbs. Three patients had to undergo below-knee amputation due to persistent infection followed by osteomyelitis resistant to parenteral antibiotic therapy and repeated debridement. Complications including infection, hardware removal, nonunion, and persistent ulcers requiring further intervention were also observed. Postoperative functional scores revealed significant improvement compared with preoperative scores on American Orthopaedic Foot and Ankle Society (AOFAS) - Hindfoot scale, Foot Function Index (FFI), visual analogue scale (VAS), and Foot and Ankle Outcome Score (FAOS). The use of retrograde intramedullary compression nail results in good rates of limb salvage when used for hindfoot reconstruction in patients with Charcot arthropathy. Cite this article: Bone Joint J 2018;100-B:190-6. ©2018 The British Editorial Society of Bone & Joint Surgery.
Dave, M B; Parmar, K D; Sachde, B A
2016-07-01
One of the points made against nailing in radius and ulna shaft fractures has been the loss of radial bow and its impact on function. The aims of the study were to assess the change in magnitude and location of the radial bow in radius and ulna shaft fractures treated with intramedullary square nails and to assess the impact of this change on functional outcome, patient reported disability and the range of motion of the forearm. We measured the magnitude of radial bow and its location in the operated extremity and compared it to the uninjured side in 32 adult patients treated with intramedullary square nailing for radius and ulna shaft fractures at our institute. The mean loss of magnitude of maximum radial bow was 2.18 mm which was statistically significant by both student-T test and Mann-Whitney U test with p value less than 0.01. The location of maximum radial bow shifted distally but was statistically insignificant. The magnitude of maximum radial bow had a negative correlation with DASH score that was statistically insignificant (R=- 0.22, p=0.21). It had a positive, statistically significant correlation to the extent of supination in the operated extremity (R = 0.66, p = 0.0004). A loss of up to 2mm of radial bow did not influence the functional outcome as assessed by criteria reported by Anderson et al. The magnitude of radial bow influenced the supination of the forearm but not the final disability as measured by DASH score. Intramedullary nailing did decrease the magnitude of radial bow but a reduction of up to 2mm did not influence the functional outcome.
Long-term functional outcome following intramedullary nailing of femoral shaft fractures.
el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm
2012-07-01
The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined predictors of these functional outcome scores. In a retrospective study, patients with a femoral shaft fracture but no other injuries to the lower limbs or pelvis were included. A total of 59 patients met the inclusion criteria. Functional outcome scores (Short Musculoskeletal Functional Assessment (SMFA), Western Ontario and McMaster University Osteoarthritis (WOMAC) index, Harris Hip Score (HHS) and the Lysholm knee function scoring scale) were measured at a mean of 7.8 years (± 3.5 years) postoperatively. The Visual Analogue Scale (VAS) was used to determine pain complaints of the lower limb. The range of motion (ROM) of the hip and knee joints was comparable between the injured and uninjured leg, regardless of the nailing technique. Correlation between ROM and the final outcome scores was found to be fair to moderate. Even years after surgery, 17% of the patients still reported moderate to severe pain. A substantial correlation was observed between VAS and the patient-reported outcome scores. The most significant predictor of functional outcome was pain in the lower limb. Our findings suggest that the ROM of hip and knee returns to normal over time, regardless of the nailing method used. However, pain in the lower limb is an important predictor and source of disability after femoral shaft fractures, even though most patients achieved good functional outcome scores. Copyright © 2012 Elsevier Ltd. All rights reserved.
Nail Psoriasis: A Review of Treatment Options.
Pasch, Marcel C
2016-04-01
Nail involvement affects 80-90 % of patients with plaque psoriasis, and is even more prevalent in patients with psoriatic arthritis. This review is the result of a systemic approach to the literature and covers topical, intralesional, conventional systemic, and biologic systemic treatments, as well as non-pharmacological treatment options for nail psoriasis. The available evidence suggests that all anti-tumor necrosis factor-α, anti-interleukin (IL)-17, and anti-IL-12/23 antibodies which are available for plaque psoriasis and psoriatic arthritis are highly effective treatments for nail psoriasis. Conventional systemic treatments, including methotrexate, cyclosporine, acitretin, and apremilast, as well as intralesional corticosteroids, can also be effective treatments for nail psoriasis. Topical treatments, including corticosteroids, calcipotriol, tacrolimus, and tazarotene, have also been shown to have a position in the treatment of nail psoriasis, particularly in mild cases. Finally, non-pharmacological treatment options, including phototherapy, photodynamic therapy, laser therapy, and several radiotherapeutic options, are also reviewed but cannot be advised as first-line treatment options. Another conclusion of this review is that the lack of a reliable core set of outcomes measures for trials in nail psoriasis hinders the interpretation of results, and is urgently needed.
Augmentation plating in management of failed femoral nailing.
Verma, Rahul; Sharma, Pulak; Gaur, Sanjiv
2017-08-01
Non-union following interlocking nailing is a troubling complication in treatment of shaft femur fractures. There is no clear consensus on the treatment of this problem. This research was undertaken to study the role of augmentation plating combined with exchange nailing in such cases. A prospective clinical study was undertaken from January 2010 to December 2015. Patients with aseptic femoral shaft non-union, with or without implant failure following intramedullary nailing were included in the study. Augmentation plating combined with Exchange Nailing with a 4.5mm LCP was done. Fifteen patients (nine male and six female) with an average age of 43.7 years (range 18-67 years) were treated. Average timing from the first surgery was 7.3 months. Complete clinical and radiological union was achieved in all cases in a mean duration of 5.2 months. Average duration of follow up was 12.6 months. All the patients retained the preoperative hip and knee range of motion till the last follow up. Augmentation plating combined with exchange nailing in non-unions following intramedullary nailing of femur shaft fractures is a reasonably good and effective procedure with a very high success rate. © 2017 Elsevier Ltd. All rights reserved.
Unusual penetration of a construction nail through the orbit to the cranium: a case report.
Erkutlu, Ibrahim; Alptekin, Mehmet; Dokur, Mehmet; Geyik, Murat; Gök, Abdulvahap
2011-01-01
Penetrating head and neck trauma with construction nails are uncommon life-threatening injuries and an important problem in developing countries. Assessment of the neurovascular and systemic physical status is a first requirement, and the decision concerning which surgical approach to perform for the removal of the nail is of critical importance. A 10-year-old girl was presented one hour after a fall injury with complaint of a swelling and foreign body lodgment on the left forehead. Neurological and systemic physical examinations were normal except for weak direct pupillary light reflex on the left side and the patient's state of uneasiness. Radiological investigations showed that the head of the nail had entered from the left infra-orbital region and become lodged through the orbital roof, below the frontal bone. Surgical extraction of the nail in the operating room was performed successfully using left pterional craniotomy and lateral orbitotomy technique, and there was no complication after surgery. Here, we report a case with a rare craniocerebral penetrating wound and type, with the head of the nail lodged in the anterior fossa through the orbital roof, which may be defined as 'reverse penetration of the nail'.
Interleukin 28B gene polymorphisms and Epstein-Barr virus-associated lymphoproliferative diseases.
Akay, Ela; Patel, Mauli; Conibear, Tim; Chaggar, Turren; Haque, Tanzina
2014-01-01
Single-nucleotide polymorphisms (SNPs) near the interleukin (IL) 28B gene encoding a type III interferon (IFN-λ) are the most important genetic predictors of treatment response to hepatitis C virus (HCV). This retrospective study was undertaken to determine any association between IL28B SNPs and the development of viraemia in Epstein-Barr virus (EBV)-driven acute infectious mononucleosis (IM) and post-transplant lymphoproliferative disease (PTLD). Genomic DNA extracted from plasma from 45 EBV seropositive controls and 46 acute IM, 23 non-PTLD (transplant) and 21 PTLD patients was tested by PCR for 2 SNPs within IL28B. EBV DNA levels were tested in IM and PTLD samples by a real-time quantitative PCR. No significant differences were seen in SNP frequencies at rs12979860 and rs8099917 in IM and PTLD patients compared to EBV seropositive controls and transplant patients. EBV DNA levels were lower in IM and PTLD patients with CC (a favourable genotype in HCV) at rs12979860 compared to non-CC genotypes (p = 0.055). Acute IM patients with CC had significantly lower levels of EBV DNA in plasma compared to those with non-CC genotypes (p = 0.011). Genotype CC may influence anti-viral responses of IFN-λ, thereby allowing better control of EBV viraemia during lymphoproliferation, particularly in IM.
Beattie, J Renwick; Feskanich, Diane; Caraher, M Clare; Towler, Mark R
2018-01-01
Studies have shown that Raman spectroscopic analysis of fingernail clippings can help differentiate between post-menopausal women who have and who have not suffered a fracture. However, all studies to date have been retrospective in nature, comparing the proteins in nails sourced from women, post-fracture. The objective of this study was to investigate the potential of a prospective test for hip fracture based on spectroscopic analysis of nail tissue. Archived toenail samples from post-menopausal women aged 50 to 63 years in the Nurses’ Health Study were obtained and analysed by Raman spectroscopy. Nails were matched case-controls sourced from 161 women; 82 who underwent a hip fracture up to 20 years after nail collection and 81 age-matched controls. A number of clinical risk factors (CRFs) from the Fracture Risk Assessment (FRAX) tool had been assessed at toenail collection. Using 80% of the spectra, models were developed for increasing time periods between nail collection and fracture. Scores were calculated from these models for the other 20% of the sample and the ability of the score to predict hip fracture was tested in model with and without the CRFs by comparing the odds ratios (ORs) per 1 SD increase in standardised predictive values. The Raman score successfully distinguished between hip fracture cases and controls. With only the score as a predictor, a statistically significant OR of 2.2 (95% confidence interval [CI]: 1.5-3.1) was found for hip fracture for up to 20 years after collection. The OR increased to 3.8 (2.6-5.4) when the CRFs were added to the model. For fractures limited to 13 years after collection, the OR was 6.3 (3.0-13.1) for the score alone. The test based on Raman spectroscopy has potential for identifying individuals who may suffer hip fractures several years in advance. Higher powered studies are required to evaluate the predictive capability of this test. PMID:29371785
Helfen, Tobias; Siebenbürger, Georg; Mayer, Marcel; Böcker, Wolfgang; Ockert, Ben; Haasters, Florian
2016-10-28
Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elderly. One possibility to increase the stability of the screw-bone-interface is the cement augmentation of the screw tips. A second is the use of a multiplanar angle stablentramedullary nail that might provide better biomechanical properties after fixation of 2-part-fractures. A comparison of these two treatment options augmented locking plate versus multiplanar angle stable locking nail in 2-part surgical neck fractures of the proximal humerus has not been carried out up to now. Forty patients (female/male, ≥60 years or female postmenopausal) with a 2-part-fracture of the proximal humerus (AO type 11-A3) will be randomized to either to augmented plate fixation group (PhilosAugment) or to multiplanar intramedullary nail group (MultiLoc). Outcome parameters are Disabilities of the Shoulder, Arm and Hand-Score (DASH) Constant Score (CS), American Shoulder and Elbow Score (ASES), Oxford Shoulder Score (OSS), Range of motion (ROM) and Short Form 36 (SF-36) after 3 weeks, 6 weeks, 3 months, 6 months, 12 and 24 months. Because of the lack of clinical studies that compare cement augmented locking plates with multiplanar humeral nail systems after 2-part surgical neck fractures of the proximal humerus, the decision of surgical method currently depends only on surgeons preference. Because only a randomized clinical trial (RCT) can sufficiently answer the question if one treatment option provides advantages compared to the other method we are planning to perform a RCT. Clinical Trial ( NCT02609906 ), November 18, 2015, registered retrospectively.
Wilding, Chris P; Cooper, George A; Freeman, Alexandra K; Parry, Michael C; Jeys, Lee
2016-11-01
In the unsalvageable, infected total knee arthroplasty, knee arthrodesis is one treatment option with lower reported reinfection rates compared with repeated 2-stage revision and improved function compared with amputation. One possible method for reducing incidence of recurrent infection treated by arthrodesis is the use of a silver-coated implant. We report our experience of silver-coated arthrodesis nails used for managing infected revision arthroplasty. We primarily assess the rate of reinfection and rate of amputation and report functional outcome measures. Retrospective analysis of all patients undergoing knee arthrodesis with a silver-coated arthrodesis nail between 2008 and 2014. Patient-reported data were recorded prearthrodesis and postarthrodesis (Oxford Knee Score and Short Form-36) as well as evidence of recurrent of infection, subsequent surgery, and the necessity for amputation. Eight patients underwent arthrodesis using the silver-coated arthrodesis nail. Mean duration of follow-up was 16 months (5-35 months). At the point of follow-up, there were no amputations, deaths, or implant revisions. One case of recurrent infection was successfully treated with washout and debridement. The mean prearthrodesis and postarthrodesis Oxford Knee Score difference was +8.9 points (P = .086) with significantly improved pain (P = .019), night pain (P = .021), and ease of standing (P = .003). Arthrodesis of the knee using a silver-coated intramedullary device is successful in eradicating infection and allowing limb conservation. Where infection does recur, this can be successfully treated with implant retention. The use of a silver-coated arthrodesis nail should be considered as an alternative to amputation for patients with a multiply revised and infected total knee arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.
Tibial lengthening over intramedullary nails
Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.
2016-01-01
Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351
TOXIC TRACE METALS IN MAMMALIAN HAIR AND NAILS
Data have been compiled from the available world literature on the accumulation and bioconcentration of selected toxic trace metals in human hair and nails and other mammalian hair, fur, nails, claws, and hoofs. The toxic trace metals and metalloids include antimony, arsenic, bor...
CalNail : a design tool for soil nail projects using field case histories.
DOT National Transportation Integrated Search
2006-06-01
Currently, geotechnical staff within Caltrans do not have ready access to detailed information on : previously designed soil nail walls. Much of this information is kept by individual designers, or stored in : paper format, with no organized method o...
Wood, Amber
2016-10-01
Wearing nail polish Key words: nail, polish, UV-cured, gel nail, Shellac. Preventing dry skin Key words: dry skin, chapped, dermatitis, hand hygiene. Wearing rings Key words: ring, jewelry, wedding ring, band, hand hygiene. Copyright © 2016 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Application research of 3D additive manufacturing technology in the nail shell
NASA Astrophysics Data System (ADS)
Xiao, Shanhua; Yan, Ruiqiang; Song, Ning
2018-04-01
Based on the analysis of hierarchical slicing algorithm, 3D scanning of enterprise product nailing handle case file is carried out, point cloud data processing is performed on the source file, and the surface modeling and innovative design of nail handling handle case are completed. Using MakerBot Replicator2X-based 3D printer for layered 3D print samples, for the new nail product development to provide reverse modeling and rapid prototyping technical support.
Contribution of Gypsum Wallboard to Racking Resistance of Light-Frame Walls.
1983-12-01
contribution to wall ’ ~sheathing to the framing members, and axial loads on racking resistance. Such information may lead to more diagonal braces used...wallboard was centered over the joint and fastened to the narrow face of the wood pieces using 1-1/4-inch drywall nails . Two nails were used to fasten...pulled apart placing a lateral load on the nailed connection, similar to the connector loading incurred at the nailed connection along the bottom plate of
Nail disorders in older people, and aspects of their pharmaceutical treatment.
Murdan, Sudaxshina
2016-10-30
The aim of this paper was to explore how aging influences the nail unit, its disorders and its response to treatment, and to identify some of the age-related gaps in the ungual drug delivery literature. Aging causes obvious changes to the nail, some of which are inherently due to old age, while others are due to diseases/conditions which become more prevalent as we age. Alterations in the nail plate's colour, contour, thickness, fragility, surface features, cell size, chemical composition and growth rate are some of the changes, with toenails and fingernails showing different effects. With respect to disease, the incidence of onychomycosis - the most common nail disorder - is considerably higher in older people. Similarly, brittle nails become more common as we age. In contrast, the literature about aging and the incidence of nail psoriasis is inconclusive, although, it is clear that as one gets older, the negative impact of nail psoriasis on one's quality of life decreases. Pharmaceutical treatment of the diseases comprises local and systemic therapies, sometimes in combination. Systemic therapies have the inherent disadvantages of adverse systemic effects, drug interactions and the need for monitoring, disadvantages which are especially problematic for older people who are more likely to suffer from co-morbidities and be on other medications. Topical therapy avoids such disadvantages. However, the success rates of commercially available preparations are low, and older people may need help with their application. It is also proposed that regular inspection and grooming of nails should become part of routine care of older people, as these would provide opportunities to identify and treat any problems at an earlier stage. Copyright © 2016 Elsevier B.V. All rights reserved.
Intramedullary fixation of forearm fractures with new locked nail.
Bansal, Himanshu
2011-09-01
Lack of availability of interlocked nails made plate osteosynthesis the first choice of treatment of forearm fractures inspite of more surgical exposure, periosteal stripping and big skin incision subsequent scar along with higher risk of refracture on implant removal. We hereby report the first 12 cases with 19 forearm bone fractures internally fixed by indegenous interlocked nail. Existing square nails were modified to have a broad proximal end of 5.5 mm with a hole for locking screw of 2.5 mm. The nail has a distal hole of 1/1.2/1.5 mm in 2.5/3/3.5 mm diameter nail, respectively. A new method of distal locking with a clip made of k wire is designed. The clip after insertion into the bone and hole in nail and opposite cortex snuggly fits the bone providing a secure locking system. Twelve skeletally mature patients, mean age 32 years (range 24-45 years) with 19 diaphyseal fractures of the forearm were treated with this indigenously made new nail. The patient were evaluated for fracture union, functional recovery and complications. The functional outcome was assessed by disabilities of arm, shoulder and hand questionnaire (DASH score). Time to radiographic union ranged between 12 and 28 weeks, with a 100% union rate. Complications were minimal, with mild infection in open fracture (n=1) and delayed union (n=1) in patient with comminuted fracture of the ulna only. The clinical results were excellent. The DASH score ranged between 0 and 36 points. This new interlocking nail may be considered as an alternative to plate osteosynthesis for fractures of the forearm in adults. The advantages are benefit of closed reduction, smaller residual scar, reduced cost and early union with allowance of immediate movements.
Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.
Gessmann, Jan; Königshausen, Matthias; Coulibaly, Marlon Osman; Schildhauer, Thomas Armin; Seybold, Dominik
2016-05-01
Humeral shaft nonunion after intramedullary nailing is a rare but serious complication. Treatment options include implant removal, open plating, exchange nailing and external fixation. The objective of this retrospective study was to determine whether augmentation plating without nail removal is feasible for treating a humeral shaft nonunion. Between 2002 and 2014, 37 patients (mean age 51, range 20-84 years) with aseptic humeral shaft nonunions prior to intramedullary nailing were treated with augmentation plating. The initial fractures had been fixed with retrograde nails (10 cases) or anterograde nails (27 cases). There were 34 atrophic nonunions and 3 hypertrophic nonunions. Nonunion treatment of all patients consisted of local debridement through an anterior approach to the humerus and anterior placement of the augmentation plates. Supplemental bone grafting was performed in all atrophic nonunion cases. All patients were followed until union was radiologically confirmed. Union was achieved in 36 patients (97 %) after a mean of 6 months (range 3-24 months). There was one case of iatrogenic median nerve palsy that showed complete spontaneous recovery 6 weeks postoperatively. One patient sustained a peri-implant stress fracture that was treated successfully by exchanging the augmentation plate to bridge the nonunion and the fracture. No infections or wound healing complications developed. At a mean follow-up of 14 months, all patients showed free shoulder and elbow motion and no restrictions in daily or working life. The results indicate that augmentation plating using an anterior approach is a safe and reliable option for humeral shaft nonunions after failed nailing, and the treatment has no substantial complications. Because the healing rates are similar to the standard technique of nail removal and fixation by compression or locking plates, we consider this technique to be an alternative choice for treatment.
The role of intramedullary fixation in ankle fractures - A systematic review.
Jordan, R W; Chapman, A W P; Buchanan, D; Makrides, P
2018-02-01
Ankle fractures are one of the most commonly occurring fractures in the elderly population. The overall incidence has been reported to be up to 184 fractures per 100,000 persons per year, of which 20-30% occur in the elderly. Medical co-morbidities, osteoporosis, suboptimal skin quality and poor toleration of non-weight bearing status all contribute to difficulties in managing these injuries in this population. Intramedullary implants are advantageous as they utilise smaller incisions, minimise soft tissue disruption and may allow early weight bearing. This systematic review aims to analyse the use of both fibula nails and talo-tibial-calcaneal (TTC) implants in the management of fragility ankle fractures. We conducted a systematic review of the literature using the online databases Medline and EMBASE on 26th December 2015. Only studies assessing ankle fractures that were treated with either an intramedullary fibula nail or TTC implant were included. Studies must have reported complications, patient mobility status or a functional outcome measure. Studies were excluded if the intramedullary device utilised was an adjunct to plate fixation or where a variety of surgical treatments were included in the study. The included studies were appraised with respect to a validated quality assessment scale. Our search strategy produced 350 studies although only 17 studies met inclusion criteria; ten assessed a fibula nail and seven assessed a standard hindfoot nail, a TTC implant. 15 studies were case series, the overall quality of the studies was low and only one randomised controlled trial was reviewed. The mean Olerud and Molander Ankle Score for fibula nail studies ranged from 58 to 97 and the complication rate from 0 to 22%. Two comparative studies reported a statistically significant increase in complication rate with plate fixation but similar functional outcomes. Studies assessing TTC implants reported a mean Olerud and Molander Ankle Score of 50-62 and complication rate from 18 to 22.6%. The studies reviewed suggest that fibula nails may be capable of producing similar functional outcomes with lower rates of complications to plate fixation. TTC implants produce lower functional outcomes but this may be acceptable in a subgroup of patients at high risk or with reduced pre-injury mobility. However, the low quality of evidence reviewed, the variation in patients included, implant used and outcome scores measured restricts the ability to draw definitive conclusions. Further comparative studies are required to explore the role of these implants further. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Nail care feature gets to the heart of core nursing skills.
Lindsay, Margot
2009-07-07
Thank you for drawing attention to the importance of personal hygiene in nail care (art&science June 17). Authors Bridget Malkin and Pat Berridge discuss the subject in depth and address the confusion over who should perform nail care for patients.
Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne
2016-09-01
Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dujela, Michael; Hyer, Christopher F; Berlet, Gregory C
2017-11-01
Hindfoot arthritis or significant deformity involving the ankle and subtalar joint (STJ) is a disabling condition with few salvage options. Many surgeons note a decreased STJ fusion rate compared with ankle union when a retrograde nail construct is used. The purpose of this study was to report the STJ fusion rate of tibiotalocalcaneal (TTC) arthrodesis with retrograde nail. A chart and radiographic review was performed. TTC fusions performed in patients with osteoarthritis, posttraumatic arthritis, or deformity correction with retrograde nail fixation were included. Exclusion criteria included neuropathy, Charcot arthropathy, and failed total ankle replacement. Ultimately, 66 retrograde TTC fusions (in 63 patients) met inclusion criteria. The average age was 57.0 years. There were 29 female and 34 male patients. Radiographic fusion of the ankle and STJ was demonstrated in 68.2% of the patients. There were 11 cases (16.7%) of ankle arthrodesis with STJ nonunion, 6 cases (9.1%) of STJ fusion but ankle nonunion, and 4 cases (6.1%) of stable radiographic nonunion of both joints. The mean time to subtalar fusion was 112.1 days. One patient required revision surgery and conversion to below-knee amputation. One patient required a CROW walker for assistance with gait. A 22.8% radiographic nonunion rate of the STJ was noted in retrograde TTC fusion. Despite this, patients were stable and pain free. Level IV: Retrospective Case series.
Bilateral tibial lengthening over the nail: our experience of 143 cases.
Motallebi Zadeh, Nader; Mortazavi, Seyedeh Hamideh; Khaki, Siavash; Heidari, Kazem; Karbasi, Ashraf; Ostad Rahimi, Sedigheh
2014-09-01
Using lengthening over an intramedullary nail as a technique for cosmetic purposes improves the individuals' quality of life and provides more satisfactory results due to less external fixator period. This study reports a case series of 143 individuals who underwent bilateral tibial lengthening over an intramedullary nail for cosmetic purposes together with the review of parameters related to the surgery and complications. Level of satisfaction was measured with the standard visual analog scale at least 1 year after removal of external fixator. In this study, mean (SD) age of patients was 26.6 (7.26) years. 85 (59.4%) participants were male and 58 (40.6%) were female. Mean end lengthening of all individuals was 6.65 cm. The mean external fixator period was 93.7 days. Complication rate was 0.74 per segment but it decreased to 0.45 when pin-tract infection was excluded. Complications were categorized based on Paley et al.'s classification as 129 problems, 85 obstacles and no sequelae. Interestingly, 44 (30.8%) individuals had no problem and obstacle. Lengthening over an intramedullary nail provides bone formation in equal quality to that obtained by the conventional Ilizarov method, along with lower rate of complications. The large number of individuals involved in our study is a remarkable benefit which could be used as an appropriate sample to compare results for outcomes and complications.
Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak
2014-01-01
Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899
Soil nailing of a bridge embankment : report 2 : design and field performance report.
DOT National Transportation Integrated Search
1995-07-01
Soil nailing has recently been introduced in Oregon as an alternative lateral earth support method. The first permanent soil nail wall on the state's highway system was used where an underpass was widened under the existing Oregon Slough Bridge in Po...
Functional Analysis and Treatment of Nail Biting
ERIC Educational Resources Information Center
Dufrene, Brad A.; Watson, T. Steuart; Kazmerski, Jennifer S.
2008-01-01
This study applied functional analysis methodology to nail biting exhibited by a 24-year-old female graduate student. Results from the brief functional analysis indicated variability in nail biting across assessment conditions. Functional analysis data were then used to guide treatment development and implementation. Treatment included a…
Sullivan, Ruth; Kinra, Sanjay; Ekelund, Ulf; Bharathi, A V; Vaz, Mario; Kurpad, Anura; Collier, Tim; Reddy, K Srinath; Prabhakaran, Dorairaj; Ebrahim, Shah; Kuper, Hannah
2012-02-09
Socio-cultural differences for country-specific activities are rarely addressed in physical activity questionnaires. We examined the reliability and validity of the Indian Migration Study Physical Activity Questionnaire (IMS-PAQ) in urban and rural groups in India. A sub-sample of IMS participants (n = 479) was used to examine short term (≤ 1 month [n = 158]) and long term (> 1 month [n = 321]) IMS-PAQ reliability for levels of total, sedentary, light and moderate/vigorous activity (MVPA) intensity using intraclass correlation (ICC) and kappa coefficients (k). Criterion validity (n = 157) was examined by comparing the IMS-PAQ to a uniaxial accelerometer (ACC) worn ≥ 4 days, via Spearman's rank correlations (ρ) and k, using Bland-Altman plots to check for systematic bias. Construct validity (n = 7,000) was established using linear regression, comparing IMS-PAQ against theoretical constructs associated with physical activity (PA): BMI [kg/m2], percent body fat and pulse rate. IMS-PAQ reliability ranged from ICC 0.42-0.88 and k = 0.37-0.61 (≤ 1 month) and ICC 0.26 to 0.62; kappa 0.17 to 0.45 (> 1 month). Criterion validity was ρ = 0.18-0.48; k = 0.08-0.34. Light activity was underestimated and MVPA consistently and substantially overestimated for the IMS-PAQ vs. the accelerometer. Criterion validity was moderate for total activity and MVPA. Reliability and validity were comparable for urban and rural participants but lower in women than men. Increasing time spent in total activity or MVPA, and decreasing time in sedentary activity were associated with decreasing BMI, percent body fat and pulse rate, thereby demonstrating construct validity. IMS-PAQ reliability and validity is similar to comparable self-reported instruments. It is an appropriate tool for ranking PA of individuals in India. Some refinements may be required for sedentary populations and women in India.
2012-01-01
Background Socio-cultural differences for country-specific activities are rarely addressed in physical activity questionnaires. We examined the reliability and validity of the Indian Migration Study Physical Activity Questionnaire (IMS-PAQ) in urban and rural groups in India. Methods A sub-sample of IMS participants (n = 479) was used to examine short term (≤1 month [n = 158]) and long term (> 1 month [n = 321]) IMS-PAQ reliability for levels of total, sedentary, light and moderate/vigorous activity (MVPA) intensity using intraclass correlation (ICC) and kappa coefficients (k). Criterion validity (n = 157) was examined by comparing the IMS-PAQ to a uniaxial accelerometer (ACC) worn ≥4 days, via Spearman's rank correlations (ρ) and k, using Bland-Altman plots to check for systematic bias. Construct validity (n = 7,000) was established using linear regression, comparing IMS-PAQ against theoretical constructs associated with physical activity (PA): BMI [kg/m2], percent body fat and pulse rate. Results IMS-PAQ reliability ranged from ICC 0.42-0.88 and k = 0.37-0.61 (≤1 month) and ICC 0.26 to 0.62; kappa 0.17 to 0.45 (> 1 month). Criterion validity was ρ = 0.18-0.48; k = 0.08-0.34. Light activity was underestimated and MVPA consistently and substantially overestimated for the IMS-PAQ vs. the accelerometer. Criterion validity was moderate for total activity and MVPA. Reliability and validity were comparable for urban and rural participants but lower in women than men. Increasing time spent in total activity or MVPA, and decreasing time in sedentary activity were associated with decreasing BMI, percent body fat and pulse rate, thereby demonstrating construct validity. Conclusion IMS-PAQ reliability and validity is similar to comparable self-reported instruments. It is an appropriate tool for ranking PA of individuals in India. Some refinements may be required for sedentary populations and women in India. PMID:22321669
Erdogan, Fahri; Sarikaya, Ilker Abdullah; Can, Ata; Gorgun, Baris
2018-01-01
Total knee arthroplasty (TKA) is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA). The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Chen, Daoyun; Chen, Jianmin; Liu, Fanggang; Jiang, Yao
2011-03-01
The sequelae of poliomyelitis are the common causes of leg discrepancy. Tibial lengthening is an effective way to solve this problem but it is associated with a high rate of complications. In this study, we combined the use of humeral nail and external fixator in tibial lengthening with the purpose of reducing lengthening complications. Compared with the cases lengthened by a single-plane external fixator alone, this combined strategy was found to be beneficial in maintaining the tibial alignment. Therefore, it can be recommended as a good technique for tibial lengthening in patients with sequelae of poliomyelitis.
Jung, F; Krüger, A; Pindur, G; Sternitzky, R; Franke, R P; Gori, T
2014-01-01
The role of the microcirculation in the pathophysiology and symptoms of peripheral arterial obliterative disease (PAOD) has been progressively emphasized during the past decades. Under resting conditions, already, the tissue oxygen partial pressure in the m. tibialis anterior (pO2im) is reduced to about 50% compared to healthy subjects. In the framework of this study the pO2im of patients with PAOD stage II according to Fontaine (n=16) in the m. tibialis anterior was measured under resting conditions and during walking on a treadmill in comparison to healthy subjects (n=10). Under resting conditions the pO2im only marginally differed between PAOD patients and healthy subjects. But during exercise the pO2im dropped significantly more severely in PAOD patients and a return to baseline values could only be reached when the treadmill was stopped and the patients stood still. The pO2im minima correlated clearly with the clinical symptom of calf pain. The data revealed that the pO2im values were lower in PAOD patients and dropped significantly faster during walking compared to the pO2im values in healthy subjects. The pO2im decrease correlated with the calf pain occurring when the pO2im values approached or fell below 10 mmHg.
Oh, Sooyeon; Kim, Nayoung; Yoon, Hyuk; Choi, Yun Jin; Lee, Ju Yup; Park, Kyoung Jun; Kim, Hee Jin; Kang, Kyu Keun; Oh, Dong Hyun; Seo, A Young; Lee, Jae Woo; Shin, Cheol Min; Park, Young Soo; Oh, Jane C.; Lee, Dong Ho; Jung, Hyun Chae
2013-01-01
Background: To identify whether first-degree relatives (FDRs) of gastric cancer (GC) patients have increased risk for atrophic gastritis (AG) and intestinal metaplasia (IM) in relation to other risk factors of GC. Methods: The study cohort consisted of 224 pairs of age-sex matched controls and FDRs. AG and IM in the gastric mucosa were scored histologically using the updated Sydney classification. Risk of having AG and IM was studied by comparing FDRs to controls. Impacts of age, H. pylori infection, smoking, dietary and socioeconomic factors on the presence of AG and IM were studied. Results: In multivariate regression analysis, FDRs had adjusted OR of 2.69 (95% CI 1.06–6.80, P=0.037) for antral IM in male population. Adjusted OR for antral AG and IM were 9.28 (95% CI 4.73–18.18, P<0.001) and 7.81 (95% CI 3.72–16.40, P<0.001) for the H. pylori infected subjects in total population. Getting old by 5 years increased the ORs of having AG and IM by approximately 1.25 fold (P<0.001). Spicy food increased the OR of antral IM by 2.28 fold (95% CI 1.36–3.84, P=0.002). Conclusions: Family history of GC was an independent risk factor for antral IM in male in our study, which could be one reason for the increase of gastric cancer in the family member of gastric cancer. It could be an evidence for the necessity of frequent endoscopy in the presence of family history of GC compared to general population in male. PMID:25337541
Wang, Xinyu; Bynum, James A; Stavchansky, Solomon; Bowman, Phillip D
2014-07-05
Cellular damage from oxidative stress, in particular following ischemic injury, occurs during heart attack, stroke, or traumatic injury, and is potentially reducible with appropriate drug treatment. We previously reported that caffeic acid phenethyl ester (CAPE), a plant-derived polyphenolic compound, protected human umbilical vein endothelial cells (HUVEC) from menadione-induced oxidative stress and that this cytoprotective effect was correlated with the capacity to induce heme oxygenase-1 (HMOX1) and its protein product, a phase II cytoprotective enzyme. To further improve this cytoprotective effect, we studied a synthetic triterpenoid, 1-[2-cyano-3,12-dioxooleana-1,9(11)-dien-28-oyl]imidazole (CDDO-Im), which is known as a potent phase II enzyme inducer with antitumor and anti-inflammatory activities, and compared it to CAPE. CDDO-Im at 200nM provided more protection to HUVEC against oxidative stress than 20μM CAPE. We explored the mechanism of CDDO-Im cytoprotection with gene expression profiling and pathway analysis and compared to that of CAPE. In addition to potent up-regulation of HMOX1, heat shock proteins (HSP) were also found to be highly induced by CDDO-Im in HUVEC. Pathway analysis results showed that transcription factor Nrf2-mediated oxidative stress response was among the top canonical pathways commonly activated by both CDDO-Im and CAPE. Compared to CAPE, CDDO-Im up-regulated more HSP and some of them to a much higher extent. In addition, CDDO-Im treatment affected Nrf2 pathway more significantly. These findings may provide an explanation why CDDO-Im is a more potent cytoprotectant than CAPE against oxidative stress in HUVEC. Copyright © 2014 Elsevier B.V. All rights reserved.
Cocco, Luiz Fernando; Ejnisman, Benno; Belangero, Paulo Santoro; Cohen, Moises; Dos Reis, Fernando Baldy
2018-01-01
The treatment of humeral fractures remains controversial. Systematic reviews demonstrate similar results between dynamic compression plating and locked intramedullary nailing in the surgical treatment of these fractures. However, it appears that antegrade intramedullary nailing causes higher residual pain in the shoulder. The proposal of this work is to evaluate through the WORC protocol (Western Ontario Rotator Cuff Index) the consequences in the quality of life of patients submitted to osteosynthesis of the humerus with antegrade locked intramedullary nailing. This work is a cohort retrospective study in addition to the application of a questionnaire for self-rated quality of life with its 05 domains (WORC - Western Ontario Rotator Cuff Index) for patients ( N = 26) classified in the Trauma Sector of the Department of Orthopedics and Traumatology of the Federal University of São Paulo (DOT/UNIFESP) submitted to Humerus Osteosynthesis with Antegrade Locked Intramedullary Nailing. There was also the inclusion of data related to the time since surgery, age, sex, surgical laterality, dominance among members and work leave, which were not considered in the original protocol. After, the data were statistically assessed to evaluate the association between numerical and categorical variables. The overall WORC score was 82.75 ± 17.00 (Mean ± SD) and was not different considering sex, age and postoperative period. Among the WORC domains, both Work and Sport / Recreation Protocols were the most unfavorable factors in the evaluation of patients. Although not statistically significant, those who had the procedure on the dominant side presented a lower quality of life score than those who had the surgery on the non-dominant side. Although non-significant again, those who were away from work had an overall lower quality of life score than those who were not. The WORC Quality of Life Protocol shows good results for evaluating patients submitted to humerus osteosynthesis with antegrade locked intramedullary nailing. The data stratified by domains were good, however, Work and Sport/Recreation domains showed the lowest means compared to the other domains. Research Ethics Commitee (CEP 0676/2016) and Plataforma Brasil 56381216.3.0000.550. CAAE: 56381216.3.0000.5505.
Tucker, Adam; Warnock, Michael; McDonald, Sinead; Cusick, Laurence; Foster, Andrew P
2018-04-01
Cephalomedullary nail (CMN) failure is a rare entity following hip fracture treatment. However, it poses significant challenges for revision surgery, both mechanically and biologically. Nail failure rates have been reported at < 2%; however, no published studies have reported revision surgery procedures and their respective outcomes. We present a regional experience, with outcomes, of the revision options. We identified 20 fatigued CMNs that underwent four different revision procedures. Mean age was 73 ± 15.24 years, with a 3:1 female preponderance, and a median ASA grade of 3. Post-operative CMN radiographs demonstrated a significant number of fractures were fixed in varus, with reductions in neck-shaft angles post-operatively. A "poor" quality of reduction resulted in significantly earlier nail failure, compared to "adequate" and "good" (p = 0.027). Tip-Apex Distance (TAD) mean was 23.2 ± 8.3 mm, and an adequate TAD with three-point fixation was seen in only 35% of cases. Mean time to failure was 401.0 ± 237.2 days, with mean age at failure of 74.0 ± 14.8 years. Options after failure included revision CMN nail, proximal femoral locking plate (PFLP), long-stem or restoration arthroplasty, or femoral endoprosthesis. Barthel Functional Index scores showed no significant difference at 3 and 12 months post-operatively, nor any difference between treatment groups. Mean 12-month mortality was 30%, akin to a primary hip fracture mortality risk according to NICE guidelines. Mortality rates were lowest in revision nails. Subsequent revision rates were higher in the PFLP group. There is no reported evidence on the best surgical technique for managing the failed CMN, with no clear functional benefit in the options above. Good surgical technique at the time of primary CMN surgery is critical in minimising fatigue failure. After revision, overall mortality rates were equivalent to reported primary hip fracture mortality rates. Further multicentre evaluations are required to assess which technique convey the best functional outcomes without compromising 12-month mortality rates.
DOT National Transportation Integrated Search
1993-12-01
Finite Difference Methods (FDM) and Finite Element Methods (FEM) studies are reported studying the soil nail wall construction at the Swift Delta I-5 Interchange bridge reconstruction in North Portland, Oregon. Five layers of soil nails were installe...
Mycobacteria in nail salon whirlpool footbaths, California.
Vugia, Duc J; Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L; Desmond, Edward
2005-04-01
In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers.
Mycobacteria in Nail Salon Whirlpool Footbaths, California
Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L.; Desmond, Edward
2005-01-01
In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers. PMID:15829204
Oh, Susan; Vandergriff, Travis
2014-10-15
Scabies limited to the nail unit is quite unusual, but may persist after treatment of crusted scabies. We present a man with a history of crusted scabies that resolved with treatment, but later the patient reported a chronic problem with crumbly, thickened nails, which were found to be harboring scabies mites.
76 FR 19124 - Certain Steel Nails From the United Arab Emirates
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Preliminary)] Certain Steel Nails From the United Arab Emirates AGENCY: United States International Trade Commission. ACTION: Institution... certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the Harmonized...
Dorsal dimelia in patau syndrome: a case report.
Fattah, A; Pickford, M A
2007-10-01
We present a case of a child with Patau syndrome that exhibits features consistent with congenital palmar nail syndrome. The literature is reviewed and evidence presented to demonstrate that this is a defect in the dorso-ventral patterning of the limb and thus a form of dorsal dimelia. In order to differentiate this from other instances of ectopic nail tissue we suggest congenital palmar nail syndrome should be more specifically defined as duplicated nails, absent flexion creases, non-glabrous skin on the palmar surface, reduced movement at the interphalangeal joints and hypoplastic terminal phalanges.
Megas, Panagiotis; Syggelos, Spyros A; Kontakis, Georgios; Giannakopoulos, Andreas; Skouteris, Georgios; Lambiris, Elias; Panagiotopoulos, Elias
2009-07-01
This retrospective, multicentre study aimed to evaluate reamed intramedullary nailing (IMN) for the treatment of 30 cases of aseptic femoral shaft non-union after plating failure. Following nailing, 29 non-unions had healed by a mean 7.93 months. In one case a hypertrophic non-union required renailing after 8 months, using a nail of greater diameter, and united within five further months. Healing times were not related to whether the fracture was open or closed, the type non-union or the type of fracture. The delay from the initial plating to intramedullary nailing had a statistically significant effect on healing time and final outcome. This treatment is cost effective and should be implemented as soon as the non-union is diagnosed.
Benati, E; Ribero, S; Longo, C; Piana, S; Puig, S; Carrera, C; Cicero, F; Kittler, H; Deinlein, T; Zalaudek, I; Stolz, W; Scope, A; Pellacani, G; Moscarella, E; Piraccini, B M; Starace, M; Argenziano, G
2017-04-01
Longitudinal melanonychia might be difficult to differentiate and the use of dermoscopy can be useful for the preoperative evaluation and management decision. The aim of our study was to investigate clinical and dermoscopic criteria of acquired longitudinal melanonychia in adults to identify the best predictors of melanoma using a multivariate analysis and to explore eventual new dermoscopic criteria for nail melanoma diagnosis. In this retrospective observational study, 82 histopathologically diagnosed, acquired nail pigmented bands were collected and examined. All variables were included in the analysis and examined as possible predictors of nail melanoma. Both univariate and multivariable analyses have been performed. Among 82 cases, 25 were diagnosed as nail melanoma and 57 as benign lesions (including 32 melanocytic nevi and 25 benign melanocytic hyperplasia). Melanoma cases were significantly associated with a width of the pigmented band higher than 2/3 of the nail plate, grey and black colours, irregularly pigmented lines, Hutchinson and micro-Hutchinson signs, and nail dystrophy. Granular pigmentation, a newly defined dermoscopic criterion, was found in 40% of melanomas and only in 3.51% of benign lesions. Dermoscopic examination of longitudinal melanonychia provides useful information that could help clinicians to improve melanoma recognition. © 2016 European Academy of Dermatology and Venereology.
Health hazard evaluation report HETA 90-048-2253, Haute Nails, Norman, Oklahoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almaguer, D.; Blade, L.M.
In response to a request from the owner/operator of the Haute Nails Salon, Norman, Oklahoma, an evaluation was undertaken of possible chemical exposures from the use of nail sculpturing products. Haute Nails was an artificial nail sculpturing and tanning salon employing two full time nail sculpturers and four part time receptionists. The company was located on the first floor of a two story brick building. Long term general area air sampling was conducted for volatile organic chemicals, formaldehyde, and methacrylates; personal breathing zone air sampling was conducted for methacrylates. Ethyl-methacrylate concentrations in long term samples ranged from 10.3 to 14.1more » mg/cu m. Breathing zone concentrations of ethyl-methacrylate were 128 mg/cu m for a 7 minute sample and 78.9 mg/cu m for a 14 minute sample during nail sculpturing. Carbon-dioxide measurements exceeded the recommended level of 1000 parts per million. The authors conclude that there were no overexposures to ethyl-methylacrylate during the evaluation. The heating and air conditioning system did not provide for the mechanical exchange of outside air and no exhaust fans were located in the area served by the system. The authors recommend that an outside air supply duct be added to the present system.« less
Nails in Forensic Toxicology: An Update.
Solimini, Renata; Minutillo, Adele; Kyriakou, Chrystalla; Pichini, Simona; Pacifici, Roberta; Busardo, Francesco Paolo
2017-01-01
The analysis of nails as a keratinized matrix to detect drugs or illicit substances has been increasingly used in forensic and clinical toxicology as a complementary test, especially for the specific characteristics of stably accumulating substances for long periods of time. This allows a retrospective investigation of chronic drug abuse, monitoring continuous drug or pharmaceutical use, reveal in utero drug exposure or environmental exposures. We herein review the recent literature investigating drug incorporation mechanisms and drug detection in nails for forensic toxicological purposes. Mechanisms of drug incorporation have not yet been fully elucidated. However, some research has lately contributed to a better understanding of how substances are incorporated into nails, suggesting three potential mechanisms of drug incorporation: contamination from sweat, incorporation from nail bed and incorporation from germinal matrix. In addition, numerous methods dealing with the determination of drugs of abuse, medications and alcohol biomarkers in nails have been reported in studies over the years. The latter methods could find application in clinical and forensic toxicology. The studies herein reviewed point out how important it is to standardize and harmonize the methodologies (either pre-analytical or analytical) for nails analysis and the optimization of sampling as well as the development of proficiency testing programs and the determination of cut-off values. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Zuo, Kangkang; Qin, Wei; Guo, Qing; Palati-Ababaikeli; Qiao, Peiliu; Shen, Mingquan; Yin, Lele; Pan, Qilin; Xu, Xiaoxiong
2014-10-01
To explore the value of electromagnetic navigation interlocking intramedullary nail in the treatment of femoral shaft fracture. Between July 2012 and October 2013, 53 cases of femoral shaft fracture were treated. There were 40 males and 13 females, aged 16-52 years (mean, 38.3 years). The causes of injury were traffic accident in 28 cases, falling from height in 11 cases, falling in 7 cases, crush injury in 4 cases, and other in 3 cases. Of 53 cases, there were 3 cases of open fracture (Gustilo I degree) and 50 cases of closed fracture. Fracture was located in the proximal femur in 17 cases, middle femur in 29 cases, and distal femur in 7 cases. According to Winquist classification, 7 cases were rated as type I, 8 cases as type II, 22 cases as type III, and 16 cases as type IV; according to AO classification, 18 cases were rated as type 32-A, 28 cases as type 32-B, and 7 cases as type 32-C. The time from injury to operation was 3-11 days (mean, 5 days). Distal interlocking intramedullary nail was implanted using electromagnetic navigation. The distal locking nail operation with interlocking intramedullary nail was successfully completed under electromagnetic navigation; the one-time success rate of distal locking nail operation reached 100%; and the locking nail time was 5.0-9.5 minutes (mean, 7.0 minutes). Healing of incision by first intention was obtained after operation, and no complication of skin necrosis, infection, and sinus tract occurred. Fifty-three cases were all followed up 5-12 months (mean, 9 months). One case had hip pain and weaken middle gluteal muscle strength, and the symptoms disappeared after removing the nail. During the follow-up period, no broken nails, nail exit, infection, or re-fracture occurred. All fractures achieved clinical healing, and the healing time was 8-22 weeks (mean, 14.5 weeks). In 49 patients followed up 8 months, the Lysholm score was excellent in 44 cases, good in 4 cases, and acceptable in 1 case, with an excellent and good rate of 98%. Electromagnetic navigation system is safe and reliable, with the advantages of high positioning accuracy, short operation time, and no radiation, the clinical application of the system for distal locking nail operation can obtain excellent short-term effectiveness.
Shukla, Rajendra K; Dhuriya, Yogesh K; Chandravanshi, Lalit P; Gupta, Richa; Srivastava, Pranay; Pant, Aditya B; Kumar, Ajay; Pandey, Chandra M; Siddiqui, M Haris; Khanna, Vinay K
2017-05-01
Experimental studies have been carried out on rats to understand the influence of immobilization stress (IMS), a psychological stressor and forced swim stress (FSS), a physical stressor in the neurotoxicity of lambda-cyhalothrin (LCT), a new generation type II synthetic pyrethroid with extensive applications. No significant change in plasma corticosterone levels and blood brain barrier (BBB) permeability was observed in rats subjected to IMS (one session of 15min/day), FSS (one session of 3min/day) for 28days or LCT treatment (3.0mg/kg body weight, p.o. suspended in groundnut oil) for 3days (26th, 27th and 28th day) as compared to controls. Marginal changes in the levels of biogenic amines and their metabolites (NE, EPN, DA, HVA, DOPAC, 5-HT) in hypothalamus, frontal cortex, hippocampus, and corpus striatum were observed in rats subjected to IMS or FSS or LCT alone as compared to controls. It was interesting to note that pre-exposure to IMS or FSS followed by LCT treatment for 3days caused a marked increase in plasma corticosterone levels associated with disruption in the BBB permeability as compared to rats exposed to IMS or FSS or LCT alone. Pre-exposure to IMS or FSS followed by LCT treatment for 3days resulted to alter the levels of biogenic amines and their metabolites in hypothalamus, frontal cortex, hippocampus, and corpus striatum as compared to rats exposed to IMS or FSS or LCT alone. Although neurochemical changes were more intense in rats pre-exposed to IMS as compared to those subjected to FSS on LCT treatment, the results indicate that both psychological and physical stress could be important influencing factors in the neurotoxicity of LCT. Copyright © 2016. Published by Elsevier B.V.
Zhang, Li; Zhou, Pingping; Meng, Zhaowei; Gong, Lu; Pang, Chongjie; Li, Xue; Jia, Qiang; Tan, Jian; Liu, Na; Hu, Tianpeng; Zhang, Qing; Jia, Qiyu; Song, Kun
2017-01-01
Infectious mononucleosis (IM) due to Epstein-Barr virus infection is common. Uric acid (UA) is an important endogenous antioxidant. To the best of our knowledge, the association between UA and IM has not been comprehensively investigated to date. The aim of the present study was to investigate this association in Chinese patients. A total of 95 patients (47 men and 48 women) with IM were recruited, along with 95 healthy controls. Clinical data were classified by patient sex. Receiver operating characteristic (ROC) curve analysis was adopted to determine the cut-off values of UA for IM diagnosis and prediction. Crude and adjusted odds ratios (ORs) of UA for IM were analyzed by binary logistic regression. The UA levels were significantly lower in IM patients compared with those in controls. In addition, UA levels in men were significantly higher compared with those in women. The ROC curve demonstrated good diagnostic and predictive values of UA for IM in both sexes. The UA cut-off values were 326.00 and 243.50 µmol/l for diagnosing IM in men and women, respectively, with a diagnostic accuracy of 76.596 and 80.208%, respectively. Binary logistic regression analysis revealed a significant risk of IM in the low UA quartiles in both sexes. Following adjustments, the ORs even increased. Women with low UA levels appeared to be more susceptible to IM. For example, the crude ORs in quartile 1 were 24.000 and 52.500 for men and women, respectively, and the respective adjusted ORs were 31.437 and 301.746 (all P<0.01). To the best of our knowledge, the present study is the first to demonstrate the inverse association between UA and IM, suggesting a progressive decrease of antioxidant reserve in IM. Moreover, low UA was suggestive of IM, particularly in women. PMID:29285370
Limb Lengthening Using the PRECICETM Nail System: Complications and Results
Wiebking, Ulrich; Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian
2016-01-01
Background Three types of telescopic nails are mainly used for intramedullary limb lengthening nowadays. Despite some important advantages of this new technology (e.g. controlled distraction rate, not restricted availability, possibility to perform accordion maneuvers), few articles exist on clinical results and complications after lengthening with the PRECICETM nail (Ellipse, USA). Objectives The aim of the current study was to describe and analyze the complications associated with lengthening with the PRECICETM nail. Are the problems preventable when using the PRECICE, related to the distraction rate control, the lengthening goals and technique and handling? Methods We retrospectively reviewed the charts of 9 patients operated between 2012 and 2013 with a PRECICETM nail for a leg length discrepancy (LLD). The mean age of the patients was 32 years (range, 17 - 48 years). There were 5 femoral and 4 tibial procedures. The causes of LLD were posttraumatic (n = 5) and congenital (n = 4). The mean LLD was 36.4 ± 11.4 mm. The minimum follow-ups were 2 months (average, 5 months; range, 2 - 9 months). Results The mean distraction rate was 0.5 ± 0.1 mm/day. We observed in 7 patients differences in achieving the lengthening goals (average, 1.6 mm; range, -20.0 - 5.0 mm). Average lengthening was 34.7 ± 10.7 mm. All patients reached normal alignment and normal joint orientation. An unintentional loss of the achieved length during the consolidation phase was noticed in patients with delayed bone healing in two cases. In the first case (loss of 20mm distraction) the nail could be redistracted and the goal length was achieved. In the second case (loss of 10mm distraction) the nail broke shortly after the diagnosis and the nail was exchanged. Conclusions We report of loss of achieved length after lengthening with a telescopic nail. Weight bearing before complete consolidation of the regenerate might be a risk factor for that. Thorough examination of the limb length and careful evaluation of the radiographs are required in the follow-up period. The PRECICE nail system requires the same vigilance like the other intramedullary systems too. PMID:28144605
Sensory factors affecting female consumers' acceptability of nail polish.
Sun, C; Koppel, K; Adhikari, K
2015-12-01
The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different sensory attributes, could help a nail polish manufacturer modify or improve their nail polish formulas. Nail polish manufacturers could use the consumer cluster information to improve their marketing strategies for specific categories of their products and to target their advertising on particular consumer groups. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?
Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif
2016-12-01
This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.
Higashi, Tatsuya; Yamagata, Kenichiro; Kato, Yuina; Ogawa, Yu; Takano, Kaori; Nakaaze, Yutaro; Iriyama, Takashi; Min, Jun Zhe; Ogawa, Shoujiro
2016-05-01
Fingernail clipping is expected to be a specimen for steroid testing, because it has several advantages over blood; i.e., noninvasive collection, ease of storage, portability and handling, and possibility for an assessment of the steroid status over a relatively long and retrospective time window. In this study, we examined whether there is a difference in the nail contents between the right and left hands for five steroids [glycochenodeoxycholic acid (GCDCA), taurochenodeoxycholic acid (TCDCA), dehydroepiandrosterone sulfate (DHEAS), testosterone (TST) and cortisol (CRT)] using newly developed liquid chromatography/electrospray ionization-tandem mass spectrometry methods. The nail contents between the hands were significantly different for GCDCA, TCDCA and DHEAS, whereas those of TST and CRT only slightly differed. These results might be due to the difference in the binding affinity of each steroid for the nail keratin. The relatively hydrophilic steroids, GCDCA, TCDCA and DHEAS, may be lost from nails in daily life due to their low affinity for keratin, which would produce differences in the nail contents between the hands. Thus, the fingernail GCDCA, TCDCA and DHEAS contents may be influenced by factors other than the disease; the nail analysis is inefficient in the diagnosis of the disease associated with these steroids. On the other hand, the nail analysis looks promising for evaluation of the status of TST and CRT, which are lipophilic and inferred to be tightly bound to the keratin. In fact, the nail TST content showed a significant sex difference, just like its serum/plasma concentration. Copyright © 2016 Elsevier Inc. All rights reserved.
Bisaccia, Michele; Cappiello, Andrea; Meccariello, Luigi; Rinonapoli, Giuseppe; Falzarano, Gabriele; Medici, Antonio; Vicente, Cristina Ibáñez; Piscitelli, Luigi; Stano, Verdiana; Bisaccia, Olga; Caraffa, Auro
2018-01-01
Introduction: Distal tibial fractures are the most common long bone fractures. Several studies focusing on the methods of treatment of displaced distal tibial fractures have been published. To date, locked plates, intramedullary nails and external fixation are the three most used techniques. The aim of our study was to compare intramedullary nail (IMN) and locked plate (LP) for treatment of this kind of fracture. Materials and methods: We collected data on 81 patients with distal tibial fractures (distance from the joint between 40 and 100 mm) and we divided into two groups: IMN and LP. We compared in the 2 groups the mean operation time, the mean union time, the infection rate the rate of malunion and nonunion, the full weight bearing time. Results: No patient in the two groups developed a nonunion. None of the patients obtained a fair or poor outcome. Overall 52 patients obtained an excellent result (69.3%) and 23 obtained a good result (30.6%). Discussion: Our study results indicate a superiority of IMN over LP in terms of lower rates of infections and statistically significant shorter time to full weight bearing. Whereas LP appeared to be advantageous over IMN in terms of leading to a better anatomical and fixed reductions of the fracture and a lower rate of union complications. The two treatments achieved comparable results in terms of operation time, hospital stay, union time and functional outcomes. PMID:29469802
Chevron nails: a normal variant in the pediatric population.
Delano, Sofia; Belazarian, Leah
2014-01-01
A 7-month-old girl was evaluated for V-shaped ridging of the fingernails consistent with chevron nails. Chevron nails are a normal variant in the pediatric population that is frequently outgrown. This case nicely demonstrates this normal finding that has so rarely been reported in the literature. © 2013 Wiley Periodicals, Inc.
Fractures above and below a modular nail for knee arthrodesis. A case report.
Hinarejos, Pedro; Ginés, Alberto; Monllau, Juan C; Puig, Lluis; Cáceres, Enric
2005-06-01
Several techniques have been advocated for knee arthrodesis, and there has been an increasing interest in modular intramedullary nails in the recent last years. We report a case of femoral and tibial fractures at each end of a modular nail in a solidly fused knee 8 months after an arthrodesis.
Code of Federal Regulations, 2013 CFR
2013-07-01
... shipbreaking. (a) General requirements. (1) The use of ladders with broken or missing rungs or steps, broken or... 10d common wire nails or fastened with through bolts or other fasteners of equivalent strength. Cleats... nailed to each rail with five 10d common wire nails or fastened with through bolts or other fasteners of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-22
... United Arab Emirates: Postponement of Preliminary Determination of Antidumping Duty Investigation AGENCY... antidumping duty investigation on nails from the United Arab Emirates. See Certain Steel Nails From the United Arab Emirates: Initiation of Antidumping Duty Investigation, 76 FR 23559 (April 27, 2011). The notice...
The study on length and diameter ratio of nail as preliminary design for slope stabilization
NASA Astrophysics Data System (ADS)
Gunawan, Indra; Silmi Surjandari, Niken; Muslih Purwana, Yusep
2017-11-01
Soil nailing technology has been widely applied in practice for reinforced slope. The number of studies for the effective design of nail-reinforced slopes has also increased. However, most of the previous study was focused on a safety factor of the slope; the ratio of length and diameter itself has likely never been studied before. The aim of this study is to relate the length and diameter ratio of the nail with the safety factor of the 20 m height of sand slope in the various angle of friction and steepness of the slope. Simplified Bishop method was utilized to analyze the safety factor of the slope. This study is using data simulation to calculate the safety factor of the slope with soil nailing reinforcement. The results indicate that safety factor of slope stability increases with the increase of length and diameter ratio of the nail. At any angle of friction and steepness of the slope, certain effective length and diameter ratio was obtain. These results may be considered as a preliminary design for slope stabilization.
Study on laser-assisted drug delivery with optical coherence tomography
NASA Astrophysics Data System (ADS)
Tsai, Wen-Guei; Tsai, Ting-Yen; Yang, Chih-Hsun; Tsai, Meng-Tsan
2017-04-01
The nail provides a functional protection to the fingertips and surrounding tissue from external injuries. Nail plate divided into three layers including dorsal, intermediate, and ventral layers. The dorsal layer consists of compact, hard keratins, limiting topical drug delivery through the nail. In this study, we investigate the application of fractional CO2 laser that produces arrays of microthermal ablation zones (MAZs) to facilitate drug delivery in the nails. Moreover, optical coherence tomography (OCT) is implemented for real-time monitoring of the laser-skin tissue interaction, sparing the patient from invasive surgical sampling procedure. Observations of drug diffusion through the induced MAZ array are achieved by evaluating the time-dependent OCT intensity variance. Subsequently, nails are treated with cream and liquid topical drugs to investigate the feasibility and diffusion efficacy of laser-assisted drug delivery. Our results show that fractional CO2 laser improves the efficacy of topical drug delivery in the nail plate, and that OCT could potentially be used for in vivo monitoring of the depth of laser penetration as well as real-time observations of drug delivery.
New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study
Eisenstein, Emmanuel D.; Rodriguez, Mario
2016-01-01
Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice. PMID:27818800
New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study.
Eisenstein, Emmanuel D; Rodriguez, Mario; Abdelgawad, Amr A
2016-01-01
Introduction . Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods . We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results . Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion . Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.
A novel method for assessing chronic cortisol concentrations in dogs using the nail as a source.
Mack, Z; Fokidis, H B
2017-04-01
Cortisol, a glucocorticoid secreted in response to stress, is used to assess adrenal function and mental health in clinical settings. Current methods assess cortisol sources that reflect short-term secretion that can vary with current stress state. Here, we present a novel method for the extraction and quantification of cortisol from the dog nail using solid phase extraction coupled to enzyme-linked immunosorbent assay. Validation experiments demonstrated accuracy (r = 0.836, P < 0.001) precision (15.1% coefficients of variation), and repeatability (14.4% coefficients of variation) with this method. Furthermore, nail cortisol concentrations were positively correlated to an established hair cortisol method (r = 0.736, P < 0.001). Nail cortisol concentrations did not differ with dog sex, breed, age, or weights; however, sample size limitations may preclude statistical significance. Nail cortisol may provide information on cortisol secretion integrated over the time corresponding to nail growth and may be useful as a tool for diagnosing stress and adrenal disorders in dogs. Copyright © 2016 Elsevier Inc. All rights reserved.
Epithelium-derived Wnt ligands are essential for maintenance of underlying digit bone
Takeo, Makoto; Hale, Christopher S.; Ito, Mayumi
2018-01-01
Clinically, many nail disorders accompany bone deformities, but whether the two defects are causally related is under debate. To investigate the potential interactions between the two tissue types, we analyzed epithelial-specific β-catenin deficient mice, in which nail differentiation is abrogated. These mice showed regression of not only the nail plate but also of the underlying digit bone. Characterization of these bone defects revealed active bone resorption, which is suppressed by Wnt activation in osteoblast and osteoclast precursors. Furthermore, we found that Wntless (Wls) expression, essential for Wnt ligand secretion, was lacking in the β-catenin deficient nail epithelium and that genetic deletion of Wls in the nail epithelium led to the lack of Wnt activation in osteoblast and osteoclast precursors and subsequently led to defective regression of the underlying digit bone. Together, these data show epithelial Wnt ligands can ultimately regulate Wnt signaling in osteoblasts and osteoclast precursors, known to regulate bone homeostasis. These results reveal a critical role for the nail epithelium on the digit bone during homeostatic regeneration and show that Wnt/β-catenin signaling is critical for this interaction. PMID:27021406
Nail haemorrhages in native highlanders of the Peruvian Andes
Heath, Donald; Harris, Peter; Williams, David; Krüger, Hever
1981-01-01
Nail haemorrhages are of interest to the chest physician and cardiologist. While the common type in the distal part of the nail is produced by the minor trauma of daily life, the rarer form—scattered through the nail substance—appears to be related to hypoxaemia brought about by heart and lung disease. We thought it would be of interest to study a population which was naturally hypoxaemic because of living at high altitude. Accordingly we have studied the frequency and types of nail haemorrhage in Quechua Indians who are permanently exposed to the hypobaric hypoxia of the Andes. We found the haemorrhages to be common both in mestizos living on the coastal plain and in the native highlanders. They appeared to increase in frequency with altitude but were of the distal type and would thus seem to be the result of minor trauma as at sea level. However, just as in cases of cyanotic congenital heart disease at low altitude, those with exaggerated hypoxaemia and pronounced elevation of haematocrit—namely, subjects with Monge's disease (chronic mountain sickness)—had scattered haemorrhages in the nail substance. Images
Tibiotalocalcaneal Arthrodesis Using a Nitinol Intramedullary Hindfoot Nail.
Hsu, Andrew R; Ellington, J Kent; Adams, Samuel B
2015-10-01
Tibiotalocalcaneal (TTC) arthrodesis using an intramedullary hindfoot nail is a common procedure for deformity correction and the treatment of combined tibiotalar and subtalar end-stage arthritis. Nonunion at one or both fusion sites is a difficult complication that can result in reoperation, significant morbidity, and below-knee amputation. There is currently a need for sustained compression across fusion sites using a TTC hindfoot nail with good mechanical stability. The DynaNail TTC Fusion System (MedShape, Inc, Atlanta, GA) uses an internal nitinol compression element to apply sustained compression across the tibiotalar and subtalar joints after surgery. In preliminary clinical cases, we have found that the nail is safe, reliable, and has promising clinical and radiographic results in settings of hindfoot arthritis, complex deformity, Charcot arthropathy, and talar avascular necrosis. Expert opinion, Level V. © 2015 The Author(s).
Anatomic structures at risk: curved hindfoot arthrodesis nail--a cadaveric approach.
Knight, Timothy; Rosenfeld, Peter; Jones, Ioan Tudur; Clark, Callum; Savva, Nick
2014-01-01
Retrograde intramedullary nailing of the hindfoot and ankle is an established procedure for salvage of severe foot and ankle deformity, arthritis, tumor, and instability. In the present study, retrograde hindfoot (tibiotalocalcaneal) arthrodesis nailing was performed using a standardized technique on 7 cadaver specimens by trained senior surgeons. The specimens were then dissected to determine the distance of the subcalcaneal structures at risk from the insertion point of the nail. The findings showed that the distance of the lateral neurovascular bundle from the edge of the nail was 6.5 (range 3.5 to 8, 95% confidence interval 5.9 to 7.1) mm. No neurovascular bundle was compromised, and all were within a previously described "safe window." Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
[The direct AAS determination of micro elements in hair and nail by base-digestion].
Ju, Hong-fang
2002-08-01
The study of micro elements is more and more extensively, and people can gain some informations by the level of micro elements in tissue. This paper tempts to dissolve hair or nail in 2 mol.L-1 NaOH and determinate nine micro elements including calcium, zinc, iron, manganese, nickel, cadmium, copper, lead and bismuth in them by base-digestion with FAAS and GFAAS. It shows that the measured value of these elements is coincident with reference articles reported, except bismuth. The elements' percent recoveries are 90.0%-110.8%. The result also shows that the level of zinc and copper in hair are higher than in nail, and the level of bismuth, cadmium and iron in hair are lower than in nail, but the level of micro elements in hair and in nail are not correlative.
[Treatment of trochanteric fractures of the femoral bone].
Wierer, I; Pospísil, M; Holubár, J; Volf, V
1994-01-01
The authors present the evaluation of some most often methods of treatment of trochanteric fractures of femur. They analyze the group of 235 patients in the years 1987 - 1991 treated for fractures by the McLaughlin technique and by Ender nailing. The first method was performed on 121 people and the technique of Ender nailing on 97 people. The results and complications of these methods of osteosynthesis are presented in the paper. The experiences of the authors confirm the advantage of Ender nailing in treating fractures of the oldest injured patients. The Ender nailing method of osteosynthesis is the more advantageous, because the operation takes less time and is easier for patients. After Ender nailing, the possibility of functional rehabilitation and walking on crutches is greater. McLaughlin osteosynthesis of these fractures proved the more advantageous in younger injured patients.
A C, Unger; E, Wilde; B, Kienast; C, Jürgens; A P, Schulz
2014-01-01
There is only sparse data on clinical results and complications of the third-generation Gamma nailing system (Gamma3, Stryker). Therefore, we started a large multi-centre case series in 2008. The aim of this paper is to present the study design and early results of a single arm of a prospective, consecutive, monitored, post-market follow-up evaluation of Gamma3 nails. From September 2009 to January 2012, 154 consecutive patients with an average age of 80 ± 1.43 years (50-99 years) and a trochanteric femoral fracture were included in the local arm of the trial. All patients that fulfilled the inclusion criteria were treated with a Gamma3 nail. Preoperative variables included age, gender, fracture classification, walking ability (Merle d'Aubigné score), daily activity level (retrospective Zuckerman score), ASA rating of operative risk, waiting time for operation, use of walker or crutches and body mass index (BMI). Skin-to-skin time, fluoroscopy time, blood loss, intraoperative complications and device information were recorded for each patient. Follow-up postoperative assessment was undertaken at 4, 12 and 24 months. Hip range of motion, pain around the hip and the tight, walking ability (Merle d'Aubigné score, Sahlgrenska mobility score) and management of daily life (Zuckerman score) were used to evaluate the outcome. The descriptive data of age, gender, BMI, ASA classification, fracture type and skin-to-skin time is similar to other studies. Median fluoroscopy time was 62 seconds (range: 4-225 seconds) and significantly shorter in closed reductions. No intraoperative implant-related complication was recorded. A cut-out of the leg-screw during assessment period occurred in 2.6% patients (n = 4). At the 12-month assessment two (1.8%) non-unions were identified and two patients (1.8%) had broken the femoral shaft below the 180 mm nail after a fall. Analysis of the scores showed significantly declined mobility and activity in daily life four months after operation which increased significantly from four to 12 months and increased slightly between 12 and 24 months after fracture. A low implant-associated complication rate was achieved in geriatric patients with trochanteric femoral fractures using the Gamma3 nail. A better outcome concerning mobility, activity in daily life and complications compared to the Gamma2 nail could not be found in comparison to historic data.
Lacy, Eilyn R.; Cox, Kari K.; Wilson, W. David; Lee, Moses
2002-01-01
An imidazole-containing polyamide trimer, f-ImImIm, where f is a formamido group, was recently found using NMR methods to recognize T·G mismatched base pairs. In order to characterize in detail the T·G recognition affinity and specificity of imidazole-containing polyamides, f-ImIm, f-ImImIm and f-PyImIm were synthesized. The kinetics and thermodynamics for the polyamides binding to Watson–Crick and mismatched (containing one or two T·G, A·G or G·G mismatched base pairs) hairpin oligonucleotides were determined by surface plasmon resonance and circular dichroism (CD) methods. f-ImImIm binds significantly more strongly to the T·G mismatch-containing oligonucleotides than to the sequences with other mismatched or with Watson–Crick base pairs. Compared with the Watson–Crick CCGG sequence, f-ImImIm associates more slowly with DNAs containing T·G mismatches in place of one or two C·G base pairs and, more importantly, the dissociation rate from the T·G oligonucleotides is very slow (small kd). These results clearly demonstrate the binding selectivity and enhanced affinity of side-by-side imidazole/imidazole pairings for T·G mismatches and show that the affinity and specificity increase arise from much lower kd values with the T·G mismatched duplexes. CD titration studies of f-ImImIm complexes with T·G mismatched sequences produce strong induced bands at ∼330 nm with clear isodichroic points, in support of a single minor groove complex. CD DNA bands suggest that the complexes remain in the B conformation. PMID:11937638
The efficacy of single-stage open intramedullary nailing of neglected femur fractures.
Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel
2014-02-01
Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in treating patients with this injury, and may offer advantages in resource-constrained environments.
Liang, Chung-Yu; Lin, Tung-Yi; Lin, Yin-Ku
2013-01-01
Psoriasis of the nail greatly affects quality of life because of the difficulty in achieving long-lasting remission. Pustular psoriasis of the nail apparatus is characterized by the formation of sterile pustules, starting on one or two fingers or less often on the toes, and spontaneous improvement has rarely been observed. This case presents a girl with refractory nail psoriasis accompanied by periodic pustular eruption that responded well to topical treatment with indigo naturalis oil extract drops, achieving a remission of longer than 1 year. © 2012 Wiley Periodicals, Inc.
Füchtmeier, B; May, R; Hente, R; Maghsudi, M; Völk, M; Hammer, J; Nerlich, M; Prantl, L
2007-08-01
The biomechanical stability of a newly developed humerus nail (Sirustrade mark) for the treatment of fractures of the proximal humerus was analyzed in comparison to established systems. In total, three randomized groups were formed (n = 4 pairs) from 12 matched pairs of human cadaver humeri. All intact bones were mechanically characterized by five subsequent load cycles under bending and torsional loading. The bending moment at the osteotomy was 7.5 N m the torsional moment was 8.3 N m over the hole specimen length. Loading was consistently initiated at the distal epiphysis and the deformation at the distal epiphysis was continuously recorded. Prior to implant reinforcement, a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one humerus of each pair was stabilized with the Sirus proximal humerus nail while the counterpart was stabilized by a reference implant. In detail, the following groups were created: Sirus versus Proximal humerus nail (PHN) with spiral blade (group I); Sirus versus PHILOS plate (group II); Sirus versus 4.5 mm AO T-plate (group III). The Sirus nail demonstrated significantly higher stiffness values compared to the reference implants for both bending and torsional loading. The following distal epiphyseal displacements were recorded for a bending moment of 7.5 N m at the osteotomy: Sirus I: 8.8 mm, II: 8.4 mm, III: 7.7 mm (range 6.9-10.9), PHN 21.1 mm (range 15.7-25.2) (P = 0.005), PHILOS plate 27.5 mm (range 21.6-35.8) (P < 0.001), 4.5 AO T-plate 26.3 mm (range 24.3-33.9) (P = 0.01). The rotations corresponding to 8.3 N m torsional moment were: Sirus I: 9.1 degrees , II: 9.3 degrees , III: 10.6 degrees (range 7.5-12.2), PHN 13.5 degrees (range 10.3-15.6) (P = 0.158), PHILOS plate 15.6 degrees (range 13.7-20.8) (P = 0.007), 4.5 AO T-Platte 14.1 degrees (range 11.5-19.7) (P = 0.158). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the fracture model presented here. Supplementary, the Sirus Nail showed higher stiffness values than the PHN. However, the latter are gaining in importance due to the possibility of minimal invasive implantation. Whether this will be associated with functional advantages requires further clinical investigation.
Continuous decompression with intramedullary nailing for the treatment of unicameral bone cysts.
Masquijo, Julio Javier; Baroni, Eduardo; Miscione, Horacio
2008-08-01
To evaluate the efficacy of decompression of unicameral bone cysts (UBCs) of the long bones with intramedullary nailing and to compare responses to treatment according to location. We evaluated 48 consecutive patients treated between January 1988 and June 2000. Mean age was 10.3 years. Mean follow-up was 9.8 years. Evaluation was performed according to the radiographic criteria of Capanna. UBCs were located in the proximal humerus (n = 24), humeral shaft (n = 2), proximal femur (n = 19), distal tibia (n = 2) and fibula (n = 1). A total of 62.5% presented a pathological fracture. Successful results were observed in 89.5% (26 total healing, 17 healing with residual radiolucent areas), and there were four recurrences and, in one case, no response to treatment. There was more healing in the humerus than in the femur (92.3% versus 84.2%), and more tendency to restitution ad integrum, although the difference was not statistically significant (P = 0.1499). Intramedullary nailing is a minimally invasive method, which permits early stability and decompresses the cyst allowing healing. Significant differences were not observed among results from different locations.
Heat profiles of laser-irradiated nails
NASA Astrophysics Data System (ADS)
Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A.; Kendler, Michael; Simon, Jan C.; Grunewald, Sonja
2014-01-01
Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.
Investigating relations among stress, sleep and nail cortisol and DHEA.
Doan, Stacey N; DeYoung, Gerrit; Fuller-Rowell, Thomas E; Liu, Cindy; Meyer, Jerrold
2018-03-01
In the current study, we present data investigating the relationships among stress, sleep disturbance, self-control, and levels of cortisol (CORT) and dehydroepiandrosterone (DHEA) in fingernail clippings. Currently, hair CORT is the only routinely used noninvasive, validated, biomarker of chronic exposure to stress-related hormones. Nail clippings represent an important potential alternative sample matrix for assessing chronic hormone exposure, as it offers a different timeline of hormone incorporation than scalp hair, and may be obtainable from populations in which hair either is lacking or is unavailable for cultural reasons. Moreover, there is established precedent for using fingernail clippings to attain biomarker data. However, the value of nail hormone assessment for psychological research is currently unknown due to a paucity of information on the relations between nail hormone concentrations and environmental or psychological variables. In the present study, we collected data from a low income, minority population (N = 47; 97% African American) to demonstrate feasibility and acceptability of nail collection and analysis of the adrenal steroids CORT and DHEA. Participants reported on perceived stress, sleep and self-control abilities. Correlational analyses suggest that exposure to stressful events, disturbances in sleep and waking were associated with higher levels of nail DHEA, while self-control was associated with higher levels of nail CORT. We discuss the potential importance of this methodology for investigating biological, behavioral, and subjective indices of stress and well-being.
Heat profiles of laser-irradiated nails.
Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A; Kendler, Michael; Simon, Jan C; Grunewald, Sonja
2014-01-01
Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.
Neurovascular Structures at Risk With Curved Retrograde TTC Fusion Nails.
de Cesar Netto, Cesar; Johannesmeyer, David; Cone, Brent; Araoye, Ibukunoluwa; Hudson, Parke William; Sahranavard, Bahman; Johnson, Michael; Shah, Ashish
2017-10-01
The purpose of this study was to assess the risk of iatrogenic injury to plantar neurovascular structures of the foot during insertion of a curved retrograde tibiotalocalcaneal (TTC) fusion nail. Ten below-knee thawed fresh-frozen cadaveric specimens underwent curved retrograde nailing of the ankle. The shortest distance between the nail and the main plantar neurovascular branches and injured structures were recorded during dissection. We also evaluated the relative position of these structures along 2 lines (AB, connecting the calcaneus to the first metatarsal, and BC, connecting the first and fifth metatarsal). The lateral plantar artery was found to be in direct contact with the nail 70% of the time, with a macroscopic laceration 30% of the time. The Baxter nerve was injured 20% of the time, as was the lateral plantar nerve. The medial plantar artery and nerve were never injured. The most proximal structure to cross line AB was the Baxter nerve followed by the lateral plantar artery, the nail, the lateral plantar nerve, and the medial plantar nerve. Our cadaveric anatomic study found that the most common structures at risk for iatrogenic injury by lateral curved retrograde TTC fusion nails were the lateral plantar artery and nerve, and the Baxter nerve. Determination of a true neurovascular safe zone is challenging and therefore warrants careful operative dissection to minimize neurovascular injuries.
Retrograde nailing for distal third femoral shaft fractures: a prospective study.
Acharya, K N; Rao, M R
2006-12-01
To evaluate the postoperative knee function and results of unreamed retrograde nailing for distal third femoral shaft fractures. Between January 2002 and 2003 inclusive, a consecutive series of 27 patients (with 28 fractures) who underwent retrograde nailing were prospectively evaluated. Outcome measures were union time, initiation of weight bearing, deformity and shortening, functional length of the nail, knee function assessed using a modified Knee Society Knee Score. Correlations between union time and other variables were also studied. In these patients 26 (93%) of the 28 fractures achieved union, of which 5 underwent dynamisation; the mean union time for the other 21 fractures was 4.4 months. Angular malalignment was present in 4 patients and shortening in 4 others. There was negligible correlation between union time and variables of nail-canal diameter mismatch, functional length of nail, fracture geometry, or initiation of partial weight bearing ambulation. Knee flexion of more than 100 degrees was achieved in 26 patients. 19 patients had anterior knee pain and 10 had instability. By the end of one year, excellent or good scores for pain and function were recorded in 77% and 73% respectively, of the 26 patients. In view of such favourable union rates but significant deterioration in overall knee joint function, at best retrograde nailing is a reliable alternative in the management of selected complicated fractures of the distal femoral shaft.
Stanislawczuk, Rodrigo; Reis, Alessandra; Loguercio, Alessandro D
2011-01-01
This study evaluated the effect of 2% chlorhexidine-containing acid (Ac/CHX) and 2% chlorhexidine digluconate solution (CHX) on immediate (IM) and 2-year (2Y) resin-dentin bond strength (BS) and silver nitrate uptake (SNU) for two simplified etch-and-rinse adhesives. Forty-two caries-free extracted molars had a flat dentin surface exposed. In the control groups (groups 1), the surfaces were acid etched with conventional phosphoric acid and the adhesives Prime&Bond NT (PB) or Adper Single Bond 2 (SB) was applied after rinsing, drying and rewetting with water. In groups 2, Ac/CHX groups the adhesives were applied in a similar manner; however a 2% CHX-containing acid was previously applied. In groups 3, the adhesives were applied according to the control group; however the rewetting procedure was performed with an aqueous solution of 2% CHX for 60s. Composite build-ups were constructed incrementally and microtensile specimens (0.8mm(2)) were prepared for microtensile bond strength testing in the IM or 2Y periods at 0.5mm/min. For SNU, 2 bonded sticks from each tooth were coated with nail varnish, placed in the silver nitrate, polished down with SiC papers and analysed by EDX-SEM. The data from each adhesive was submitted to a two-way repeated measures ANOVA and Tukey's test (α=0.05). After 2Y, significant reductions of BS were observed for both adhesives in the control group (p<0.05). In Ac/CHX or CHX groups the BS remained stable for both systems. SNU was more evident in the control than in the experimental groups (p<0.05) both in IM and 2Y periods. The use of CHX in an aqueous solution or associated with the acid conditioner was effective to reduce the degradation of dentin bonds over a 2-year period. The addition of CHX digluconate in the acidic conditioner may be an excellent tool to increase the long-term stability of collagens fibrils within the hybrid layer against host-derived metalloproteinases without the need for additional steps for the bonding protocol. Copyright © 2010 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
...), the Department received a NSR request from Shanghai Colour Nail Co., Ltd. (``Shanghai Colour''). Shanghai Colour's request was properly made during August 2010, which is the annual anniversary of the Antidumping Duty Order. Shanghai Colour certified that it is the exporter and Wuxi Colour Nail Co., Ltd...
The Hammer-and-Nail Phenomenon in Mathematics Education
ERIC Educational Resources Information Center
Lim, Kien H.
2012-01-01
This paper uses the hammer-and-nail metaphor to highlight the rigidity and impulsiveness that can be found in student mathematical behaviour. The hammer-and-nail phenomenon can be attributed to two plausible causes: (1) the way the human mind works; and (2) the way mathematics is traditionally taught in school. In this paper, the following aspects…
Wright, Jennifer G; Plikaytis, Brian D; Rose, Charles E; Parker, Scott D; Babcock, Janiine; Keitel, Wendy; El Sahly, Hana; Poland, Gregory A; Jacobson, Robert M; Keyserling, Harry L; Semenova, Vera A; Li, Han; Schiffer, Jarad; Dababneh, Hanan; Martin, Sandra K; Martin, Stacey W; Marano, Nina; Messonnier, Nancy E; Quinn, Conrad P
2014-02-12
We evaluated an alternative administration route, reduced schedule priming series, and increased intervals between booster doses for anthrax vaccine adsorbed (AVA). AVA's originally licensed schedule was 6 subcutaneous (SQ) priming injections administered at months (m) 0, 0.5, 1, 6, 12 and 18 with annual boosters; a simpler schedule is desired. Through a multicenter randomized, double blind, non-inferiority Phase IV human clinical trial, the originally licensed schedule was compared to four alternative and two placebo schedules. 8-SQ group participants received 6 SQ injections with m30 and m42 "annual" boosters; participants in the 8-IM group received intramuscular (IM) injections according to the same schedule. Reduced schedule groups (7-IM, 5-IM, 4-IM) received IM injections at m0, m1, m6; at least one of the m0.5, m12, m18, m30 vaccine doses were replaced with saline. All reduced schedule groups received a m42 booster. Post-injection blood draws were taken two to four weeks following injection. Non-inferiority of the alternative schedules was compared to the 8-SQ group at m2, m7, and m43. Reactogenicity outcomes were proportions of injection site and systemic adverse events (AEs). The 8-IM group's m2 response was non-inferior to the 8-SQ group for the three primary endpoints of anti-protective antigen IgG geometric mean concentration (GMC), geometric mean titer, and proportion of responders with a 4-fold rise in titer. At m7 anti-PA IgG GMCs for the three reduced dosage groups were non-inferior to the 8-SQ group GMCs. At m43, 8-IM, 5-IM, and 4-IM group GMCs were superior to the 8-SQ group. Solicited injection site AEs occurred at lower proportions in the IM group compared to SQ. Route of administration did not influence the occurrence of systemic AEs. A 3 dose IM priming schedule with doses administered at m0, m1, and m6 elicited long term immunological responses and robust immunological memory that was efficiently stimulated by a single booster vaccination at 42 months. A priming series of 3 intramuscular doses administered at m0, m1, and m6 with a triennial booster was non-inferior to more complex schedules for achieving antibody response. Published by Elsevier Ltd.
Gorse, Geoffrey J; Falsey, Ann R; Fling, John A; Poling, Terry L; Strout, Cynthia B; Tsang, Peter H
2013-05-01
To increase vaccine acceptance, intradermal (ID) influenza vaccine (Fluzone(®) Intradermal, Sanofi Pasteur Inc.) may be an attractive alternative to intramuscular (IM) vaccination due to smaller needle and volume injected. A multicenter, randomized (2:1 ID vs IM vaccines) study, blinded for ID vaccine lots, was conducted among 4292 adults 18-64 years of age enrolled in October 2008. Three lots of investigational trivalent influenza vaccine containing 9μg hemagglutinin (HA) per strain in 0.1mL administered ID with a 30 gauge, 1.5mm long needle were compared to standard dose vaccine (0.5mL containing 15μg HA/strain) given IM. The post-vaccination antibody geometric mean titers (GMT) for the ID vaccine were similar to the IM vaccine (H1N1: 193.2 vs. 178.3, H3N2: 246.7 vs. 230.7, and B: 102.5 vs. 126.9). Non-inferiority was met for the ID vaccine compared to IM vaccine as assessed by antibody GMT ratios (IM/ID) for all three virus strains (H1N1: 0.92, H3N2: 0.94, and B: 1.24). Seroconversion rates were non-inferior for H1N1 and H3N2, but not for B (ID vs. IM: H1N1: 61.2% vs. 60.5%, H3N2: 75.3% vs. 74.8%, and B: 46.2% vs. 54.2%). Seroprotection (HAI titer ≥1:40) rates were similar between groups (ID vs. IM, H1N1: 91.1% vs. 91.7%, H3N2: 90.7% vs. 91.4%, and B: 87.4% vs. 89.3%). Local injection site reactions overall were more common with ID than IM vaccine (ID vs. IM: 89.2% vs. 60.2%), but were usually grade 1 or 2 and transient. The frequencies of local injection site pain and systemic reactions were similar between vaccine groups, except more myalgia with IM vaccine. The ID vaccine elicited immune responses comparable to IM vaccine except for the seroconversion rate to B virus. With the exception of pain, local injection site reactions were more common with the ID vaccine, but well-tolerated and of short duration. ClinicalTrials.gov identifier: NCT00772109. Copyright © 2013 Elsevier Ltd. All rights reserved.
Management of Nail Bed Injuries Associated with Fingertip Injuries.
George, Alexander; Alexander, Reena; Manju, C
2017-01-01
Management of nail injuries can often be a challenging experience, especially in presence of complex fingertips' injuries that include soft tissue loss and distal phalanx injury. Most studies found in the literature focus on individual injuries and describe methods to tackle those injuries, notwithstanding the fact that the nail, nailbed, distal phalanx, soft tissue and skin of the finger tip form a complex and often more than one element of this complex is injured. This retrospective study therefore focuses on the management of nail bed injuries as a part of the complex finger tip injury and outlines the surgical principles and techniques that were used in their management. Two hundred and forty patients from a tertiary care center in different clinical settings where a wide variety of cases involving the nail bed injuries were included in this study. Patients comprised of 192 (80%) males and 48 (20%) females with the average male age of 37.3 years (range 1-66 years) and average female age of 29 years (range 1-59 years). 210 patients had single finger involment, 30 patients had two finger involvement (total fingers involved- 270). The middle finger was most commonly involved while the index finger was the second most commonest finger involved. In 198 (89.18%) patients local anaesthesia was used while in the rest: regional blocks [ n = 10 (4.5%)] and general anaesthesia [ n = 14 (6.3%)] were used. In this retrospective study, out of the total of two hundred and forty patients, 222 (92.5%) patients underwent surgery, while the rest 18 (7.5%) were treated conservatively. Two hundred and ten patients who underwent surgery had complete healing over the course of treatment and followup, while four patients needed secondary interventional. Eight patients who had surgery were migrant workers were lost to follow up after surgery. Eight patients had postoperative complications that included infection, secondary necrosis, wound breakdown and non healing fractures. Accurate and timely diagnosis of nail bed injury and its meticulous repair is cardinal to the management of any nail bed injury. However all nail bed injuries must be seen in the context of associated injuries of the finger tip complex, namely skin, soft tissue and distal phalanx injuries. Fixation of associated bony injury which closely underlines the nail bed and provides physical support to the nail bed along with correction of soft tissue injuries in the form of flaps or grafts, compounded by the repair or replacement of nail plate in the first 24 hours.
Knee arthodesis using a modular customized intramedullary nail.
Letartre, R; Combes, A; Autissier, G; Bonnevialle, N; Gougeon, F
2009-11-01
Arthrodesis of the knee, particularly in infectious situations, can be achieved using either an external fixator or an intramedullary device. The objective of this study is to report the clinical, functional, and radiographic outcomes of a continuous series of 19 cases of knee arthrodesis using a customized modular intramedullary nailing system. The modular intramedullary nail offers a satisfactory functional result while maintaining limb length, in spite of a nonunion risk, since acting like a true endoprosthesis. In our retrospective series of 19 patients, the main source of patients were infected total knee replacements. The nail was customized from assembling a dual surface-sanded titanium component (femoral and tibial). The Lequesne Algofunctional score and the WOMAC score were recorded, as well as the length discrepancy between the lower extremities. Arthrodesis consolidation and the nail's fit in the shaft were verified on anterior-posterior (AP) and lateral radiographs. Five complications were observed: one anterior cortical break, one excessive tibial rotation, two cases of delayed union, and one nail revision due to residual nail instability. The postoperative Lequesne Algofunctional score was 13/24 and the WOMAC score 57/100. The nonunion rate was 32%. From a functional point of view, the patients who did not achieve complete union and those who did had similar scores. The subjective results were not as good in patients who did not achieve final consolidation. Modular intramedullary nailing simplifies the technique, shortens the procedure, and reduces the amount of blood loss at surgery. Our nonunion rate was high, although the functional result did not seem compromised by such nonunion. The risk of long-term implant failure was not studied and requires longer follow-up studies. Level IV therapeutic study. 2009 Published by Elsevier Masson SAS.
[Results of femoral lengthening over an intramedullary nail and external fixator].
Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz
2008-01-01
Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.
Debarbieux, S; Gaspar, R; Depaepe, L; Dalle, S; Balme, B; Thomas, L
2015-04-01
Ex vivo fluorescence confocal microscopy (FCM) permits real-time imaging of freshly excised skin tissues. Its usefulness as a time-sparing alternative to frozen sections in Mohs surgery of basal cell carcinoma is well documented. The purpose of this study was to describe the ex vivo FCM features of a series of benign and malignant nonpigmented tumours of the nail unit, and to correlate them with conventional histopathology. Nail apparatus tumours from 10 patients were imaged during surgical exploration using ex vivo FCM after immersion in acridine orange. Confocal mosaics of the freshly performed biopsies were evaluated in real time and retrospectively compared with haematoxylin and eosin sections. Our series included two invasive epithelial tumours (Group 1), four in situ or minimally invasive squamous cell carcinomas (SCC) (Group 2), three benign epithelial tumours (Group 3) and one nodular melanoma (Group 4). The correlation was excellent for malignant epithelial tumours exhibiting marked cytological and architectural atypias (Bowen disease, invasive SCC and onycholemmal carcinoma). Onychomatricomas exhibited a very peculiar aspect with densely cellular papillae. The correlation was less favourable for minimally invasive well-differentiated SCCs with slight cytological atypias. The correlation was poor for our case of amelanotic invasive subungual melanoma. Ex vivo FCM could be a useful tool to shorten management of nonpigmented nail tumours: in the case of a malignant tumour, it could indeed lead to performing wide excision during the same surgical procedure and possibly assessing the surgical margins. © 2014 British Association of Dermatologists.
Limb lengthening over a nail can safely reduce the duration of external fixation
Chaudhary, Milind
2008-01-01
Background: Limb lengthening using Ilizarov external fixation is safe, but the consolidation phase tends to take too long. A method that can safely reduce the time spent in external fixation would help increase patient tolerance and comfort. We report our results of lengthening over nails (LON) method in which an interlocking nail was used along with an Ilizarov external fixator to reduce external fixation duration in limb lengthening. This is a retrospective study. Materials and Methods: Twenty-seven lengthening surgeries were done with the LON method in 23 patients with 22 tibiae and five femora during the last 12 years. Length gain ranged from 1.5 cm to a maximum of 9.8 cm with a mean of 4.6 cm. The mean modified Paley difficulty score was 7.6 points. Fourteen associated procedures were performed in these patients, including equinus contracture releases, supracondylar osteotomies, ilizarov hip reonstruction and ankle fusion. We had a 29% rate of complications which included one problem, three obstacles and four complications with no serious deep intramedullary infections. Our rate of complications compares favorably with series reported in the literature. External fixation duration was reduced significantly to a mean of 17.8 days per cm. Conclusions: A combination of intramedullary nailing along with external fixation significantly reduces external fixation time while maintaining low rate of complications. Great care needs to be taken to prevent pin track infection and deep intramedullary sepsis. PMID:19753160
2017-01-01
Purpose. The purpose of this study is to evaluate the learning curve of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures, to provide valuable information and experience for surgeons who decide to learn a new procedure. Methods. We retrospectively analyzed data from 53 patients who underwent surgery using an InterTan intramedullary nail at our hospital between July 2012 and September 2015. The negative exponential curve-fit regression analysis was used to evaluate the learning curve. According to 90% learning milestone, patients were divided into two group, and the outcomes were compared. Results. The mean operative time was 69.28 (95% CI 64.57 to 74.00) minutes; with the accumulation of surgical experience, the operation time was gradually decreased. 90% of the potential improvement was expected after 18 cases. In terms of operative time, intraoperative blood loss, hospital stay, and Harris hip score significant differences were found between two groups (p = 0.009, p = 0.000, p = 0.030, and p = 0.002, resp.). Partial weight bearing time, fracture union time, tip apex distance, and the number of blood transfusions and complications were similar between two groups (p > 0.5). Conclusion. This study demonstrated that the learning curve of performing surgery with the InterTan intramedullary nail is acceptable and 90% of the expert's proficiency level is achieved at around 18 cases. PMID:28503572
Intramedullary nails with two lag screws.
Brown, C J; Wang, C J; Yettram, A L; Procter, P
2004-06-01
To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cut-out to occur. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws. Comparative analyses demonstrate that two lag screws may be advantageous in patients whose cancellous bone quality is good and who impose large loads on the lag screw/nail interface. However, the use of two screws might pre-dispose to failure by cut-out of the lag screws. The addition of a slotted hole for the upper lag screw appears to do nothing significant to reduce the risk of such a failure. Copyright 2004 Elsevier Ltd.
Shukla, Rajendra K; Gupta, Richa; Srivastava, Pranay; Dhuriya, Yogesh K; Singh, Anshuman; Chandravanshi, Lalit P; Kumar, Ajay; Siddiqui, M Haris; Parmar, Devendra; Pant, Aditya B; Khanna, Vinay K
2016-02-01
Role of immobilization stress (IMS), a psychological stressor and forced swim stress (FSS), a physical stressor was investigated on the neurobehavioral toxicity of lambda-cyhalothrin (LCT), a new generation type-II synthetic pyrethroid. Pre-exposure of rats to IMS (15 min/day) or FSS (3 min/day) for 28 days on LCT (3.0 mg/kg body weight, p.o.) treatment for 3 days resulted to decrease spatial learning and memory and muscle strength associated with cholinergic-muscarinic receptors in frontal cortex and hippocampus as compared to those exposed to IMS or FSS or LCT alone. Decrease in acetylcholinesterase activity, protein expression of ChAT and PKC-β1 associated with decreased mRNA expression of CHRM2, AChE and ChAT in frontal cortex and hippocampus was also evident in rats pre-exposed to IMS or FSS on LCT treatment, compared to rats exposed to IMS or FSS or LCT alone. Interestingly, changes both in behavioral and neurochemical endpoints were marginal in rats subjected to IMS or FSS for 28 days or those exposed to LCT for 3 days alone, compared to controls. The results suggest that stress is an important contributor in LCT induced cholinergic deficits. Copyright © 2016 Elsevier Ltd. All rights reserved.
Müller, M; Freude, T; Stöckle, U; Kraus, T M
2017-02-01
Closed reduction and intramedullary nailing is common in diaphyseal clavicle fractures. The aim of this report is to demonstrate a surgical method with minimally invasive percutaneous reduction in cases where closed reduction fails. The procedure is associated with good cosmetic results. Percutaneous reduction using two reduction forceps enables intramedullary nailing without an open procedure. Open, multifragmented or non-dislocated fractures, oblique fractures due to postoperative dislocation or shortening risk, fracture having potential to become compound fractures, neurovascular complications, pseudoarthroses. The patient is in beach-chair position. After an incision, the nail is entered from medial, two reduction forceps are mounted percutaneously at the lateral and medial fragment. After reduction the nail is pushed forward into the lateral fragment. Thereby, the fracture hematoma is not disturbed for the most part. Early functional rehabilitation with maximal abduction and anteversion of 90° for 6 weeks. Anatomic reduction can be achieved with mild cosmetic impairment.
Invasive onychocytic carcinoma.
Wang, Lei; Gao, Tianwen; Wang, Gang
2015-05-01
Neoplasms originating from nail matrix keratinocytes are very rare. Onychomatricoma and onychocytic matricoma are benign tumors arising from nail matrix keratinocytes. Only one case of onychocytic carcinoma, the malignant counterpart of onychocytic matricoma, has been reported in the literature. Herein, we describe a case of invasive onychocytic carcinoma. Two biopsy specimens of the tumor, obtained at early and invasive stages, were examined histopathologically. The first biopsy specimen showed a retiform proliferation of eosinophilic and basophilic cells in the nail matrix. The second biopsy specimen showed a retiform basophilic cell proliferation with focal keratinization. Similar to normal nail matrix keratinocytes, the proliferating basophilic cells failed to express cytokeratin (CK)1, CK6 and CK10. Focal expression of hair-specific keratins, including K31, K85 and K86, was observed. On the basis of these findings, the tumor was identified as an invasive malignant tumor originating from nail matrix keratinocytes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Refractures of the paediatric forearm with the intramedullary nail in situ.
van Egmond, Pim W; van der Sluijs, Hans A; van Royen, Barend J; Saouti, Rachid
2013-09-24
Forearm fractures in children are common. When conservative treatment fails, internal fixation with Elastic Stable Intramedullary Nailing (ESIN) become the first choice in the operative treatment of diaphyseal forearm shaft fractures. Refractures with the intramedullary nail in situ are known to occur but formal guidelines to guide management in such fractures are lacking. We present a well-documented case of a radius midshaft refracture in a 12-year-old boy with the intramedullary nail in situ, managed by closed reduction. Literature is reviewed for this type of complication, the treatment of 30 similar cases is discussed and a treatment strategy is defined. The refracture of the paediatric forearm fracture with the intramedullary nail in situ is a rare, but probably under recognised complication which is observed in approximately 2.3% of the study population. Closed reduction may be considered in these cases.
Welt, C K; Gudmundsson, J A; Arason, G; Adams, J; Palsdottir, H; Gudlaugsdottir, G; Ingadottir, G; Crowley, W F
2006-12-01
The Rotterdam criteria for polycystic ovary syndrome (PCOS) defines discrete subgroups whose phenotypes are not yet clear. The phenotypic characteristics of women in the PCOS subgroups defined by the Rotterdam criteria were compared. The study was observational. Subjects were studied in an outpatient setting in Boston and Reykjavik. Four subgroups of subjects with PCOS defined by 1) irregular menses (IM), hyperandrogenism (HA), and polycystic ovary morphology (PCOM, n = 298); 2) IM/HA (n = 7); 3) HA/PCOM (n = 77); and 4) IM/PCOM (n = 36) and a group of controls (n = 64), aged 18-45 yr, were examined. Subjects underwent a physical exam; fasting blood samples for androgens, gonadotropins, and metabolic parameters; and a transvaginal ultrasound. The phenotype was compared between groups. Ninety-seven percent of women with IM/HA had PCOM. Therefore, the groups with and without PCOM were combined. The Ferriman-Gallwey score and androgen levels were highest in the hyperandrogenic groups (IM/HA and HA/PCOM), whereas ovarian volume was higher in all PCOS subgroups compared with controls, as expected based on the definitions of the PCOS subgroups. Body mass index and insulin levels were highest in the IM/HA subgroup. Subjects with PCOS defined by IM/HA are the most severely affected women on the basis of androgen levels, ovarian volumes, and insulin levels. Their higher body mass index partially accounts for the increased insulin levels, suggesting that weight gain exacerbates the symptoms of PCOS.
Cost-effectiveness of Ingenol Mebutate Gel for the Treatment of Actinic Keratosis in Greece.
Athanasakis, Kostas; Boubouchairopoulou, Nadia; Tarantilis, Filippos; Tsiantou, Vasiliki; Kontodimas, Stathis; Kyriopoulos, John
2017-05-01
The present study aimed to perform a cost-effectiveness analysis of ingenol mebutate (IM) versus other topical alternatives for the treatment of actinic keratosis (AK). The analysis used a decision tree to calculate the clinical effects and costs of AK first-line treatments, IM (2-3 days), diclofenac 3% (for 8 or 12 weeks), imiquimod 5% (for 4 or 8 weeks), during a 24-month horizon, using discrete intervals of 6 months. A hypothetical cohort of immunocompetent adult patients with clinically confirmed AK on the face and scalp or trunk and extremities was considered. Clinical data on the relative efficacy were obtained from a network meta-analysis. Inputs concerning resource use derived from an expert panel. All costs were calculated from a Greek third-party payer perspective. IM 0.015% and 0.05% were both cost-effective compared with diclofenac and below a willingness-to-pay threshold of €30,000 per quality-adjusted life-year (QALY) (€199 and €167 per QALY, respectively). Comparing IM on the face and scalp AK lesions for 3 days versus imiquimod for 4 weeks resulted in an incremental cost-effectiveness ratio of €10,868 per QALY. IM was dominant during the 8-week imiquimod period. IM use on the trunk and extremities compared with diclofenac (8 or 12 weeks) led to incremental cost-effectiveness ratios estimated at €1584 and €1316 per QALY accordingly. Results remained robust to deterministic and probabilistic sensitivity analyses. From a social insurance perspective in Greece, IM 0.015% and IM 0.05% could be the most cost-effective first-line topical field treatment options in all cases for AK treatment. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.
Wietholter, Jon P; Ponte, Charles D; Long, Dustin M
2017-10-01
Few publications have addressed the perceptions of pharmacists and physicians regarding the value of clinical pharmacist services. A survey-based study was conducted to determine whether Internal Medicine (IM) and Family Medicine (FM) pharmacists and physicians differed in their attitudes regarding the benefits of collaboration in an acute care setting. The primary objective was to evaluate perceived differences regarding self-assessment of value between IM and FM pharmacists. The secondary objective was to evaluate perceived differences of clinical pharmacist benefit between IM and FM physicians. An eight-item questionnaire assessed the attitudes and beliefs of pharmacists and physicians regarding the value of clinical pharmacy services. Surveys were emailed and participants marked their responses using a 7-point Likert scale for each item. Demographic data and overall comments were collected from each participant. Overall, 167 surveys were completed. When comparing cumulative physician and pharmacist responses, none of the eight questions showed significant differences. Statistically significant differences were noted when comparing IM and FM clinical pharmacists on five of the eight survey items; for each of these items, FM pharmacists had more favourable perceptions than their IM counterparts. No statistically significant differences were noted when comparing responses of IM and FM physicians. This study found that FM pharmacists perceived a greater benefit regarding participation in inpatient acute care rounds when compared to their IM pharmacist counterparts. Future studies are necessary to determine if other medical specialties' perceptions of clinical pharmacy provision differ from our findings and to evaluate the rationale behind specific attitudes and behaviours. © 2016 Royal Pharmaceutical Society.
Development of a high-value care subscore on the internal medicine in-training examination.
Ryskina, Kira L; Korenstein, Deborah; Weissman, Arlene; Masters, Philip; Alguire, Patrick; Smith, Cynthia D
2014-11-18
Although high-value care (HVC) that balances benefits of tests or treatments against potential harms and costs has been a recently emphasized competency for internal medicine (IM) residents, few tools to assess residents' knowledge of HVC are available. To describe the development and initial results of an HVC subscore of the Internal Medicine In-Training Examination (IM-ITE). The HVC concepts were introduced to IM-ITE authors during question development. Three physicians independently reviewed each examination question for selection in the HVC subscore according to 6 HVC principles. The final subscore was determined by consensus. Data from the IM-ITE administered in October 2012 were analyzed at the program level. U.S. IM residency programs. 362 U.S. IM residency programs with IM-ITE data for at least 10 residents. Program-level performance on the HVC subscore was compared with performance on the overall IM-ITE, the Dartmouth Atlas hospital care intensity (HCI) index of the program's primary training hospital, and residents' attitudes about HVC assessed with a voluntary survey. The HVC subscore comprised 38 questions, including 21 (55%) on managing conservatively when appropriate and 14 (37%) on identifying low-value care. Of the 362 U.S. IM programs in the sample, 41% were in a different quartile when ranked based on the HVC subscore compared with overall IM-ITE performance. Rankings by HVC subscore and HCI index were modestly inversely associated, with 30% of programs ranked in the same quartile based on both measures. Knowledge of HVC assessed from examination vignettes may not reflect practice of HVC. Although the HVC subscore has face validity and can contribute to evaluation of residents' HVC knowledge, additional tools are needed to accurately measure residents' proficiency in HVC. None.
Ramaswamy, Preeti; Babl, Franz E; Deasy, Conor; Sharwood, Lisa N
2009-02-01
Ketamine is an attractive agent for pediatric procedural sedation. There are limited data on time to discharge comparing intramuscular (IM) vs. intravenous (IV) ketamine. The authors set out to determine whether IM or IV ketamine leads to quicker discharge from the emergency department (ED) and how side effect profiles compare. All patients who had received ketamine IM or IV at a tertiary children's hospital ED during the 3-year study period (2004-2007) were identified. Prospective sedation registry data, retrospective medical records, and administrative data were reviewed for drug dosages, use of additional agents, time of drug administration to discharge, total ED time (triage to discharge), and adverse events. A subgroup analysis for patients requiring five or fewer sutures (short suture group) was performed. A total of 229 patients were enrolled (60% male) with median age of 2.8 years (IQR =1.8-4.3 years) and median weight of 15.7 kg (range = 8.7-74 kg). Ketamine was most frequently employed for laceration repair (80%) and foreign body removal (9%). Overall, 48% received ketamine IM and 52% received it IV. In the short-suture subgroup, 52% received ketamine IM, while 48% received it IV. Multivariate linear regression analysis determined time from drug administration to patient discharge as 21 minutes shorter for IV compared with IM administration, adjusted for age and number of additional doses (R(2) = -0.35; 95% CI = -0.5 to -0.19; p < 0.001). Total time in the ED (triage to discharge) comparing IV versus IM administration, adjusting for age and gender and number of additional doses, was not significantly different (p = 0.16). In the short-suture subgroup, time to discharge from administration was also shorter in the IV ketamine group (R(2) = -0.454; 95%CI = -0.66 to -0.25; p < 0.001) but similar for total time in ED (p = 0.16). Overall, adverse events occurred in 35% (95% CI = 27% to 45%) of the IM group and 20% (95% CI = 13% to 28%) of the IV group (p = 0.01). Only one patient required brief bag-mask ventilation. In this institution, time from drug injection to discharge was shorter in the IV compared to IM ketamine group, both overall and for the short-suture group. However, time from triage to discharge was similar.
Piñol, S; Sala, A; Guzman, C; Marcos, S; Joya, X; Puig, C; Velasco, M; Velez, D; Vall, O; Garcia-Algar, O
2015-11-01
Arsenic is a highly toxic element that pollutes groundwater, being a major environmental problem worldwide, especially in the Bengal Basin. About 40% of patients in our outpatient clinics come from those countries, and there is no published data about their arsenic exposure. This study compares arsenic exposure between immigrant and native children. A total of 114 children (57 natives, 57 immigrants), aged 2 months to 16 years, were recruited and sociodemographic and environmental exposure data were recorded. Total arsenic in urine, hair, and nails and arsenic-speciated compounds in urine were determined. We did not find significant differences in total and inorganic arsenic levels in urine and hair, but in organic arsenic monomethylarsenic acid (MMA) and dimethylarsinous acid (DMA) in urine and in total arsenic in nails. However, these values were not in the toxic range. There were significant differences between longer than 5 years exposure and less than 5 years exposure (consumption of water from tube wells), with respect to inorganic and organic MMA arsenic in urine and total arsenic in nails. There was partial correlation between the duration of exposure and inorganic arsenic levels in urine. Immigrant children have higher arsenic levels than native children, but they are not toxic. At present, there is no need for specific arsenic screening or follow-up in immigrant children recently arrived in Spain from exposure high-risk countries.
Petinataud, Dimitri; Berger, Sibel; Ferdynus, Cyril; Debourgogne, Anne; Contet-Audonneau, Nelly; Machouart, Marie
2016-05-01
Onychomycosis is a common nail disorder mainly due to dermatophytes for which the conventional diagnosis requires direct microscopic observation and culture of a biological sample. Nevertheless, antifungal treatments are commonly prescribed without a mycological examination having been performed, partly because of the slow growth of dermatophytes. Therefore, molecular biology has been applied to this pathology, to support a quick and accurate distinction between onychomycosis and other nail damage. Commercial kits are now available from several companies for improving traditional microbiological diagnosis. In this paper, we present the first evaluation of the real-time PCR kit marketed by Bio Evolution for the diagnosis of dermatophytosis. Secondly, we compare the efficacy of the kit on optimal and non-optimal samples. This study was conducted on 180 nails samples, processed by conventional methods and retrospectively analysed using this kit. According to our results, this molecular kit has shown high specificity and sensitivity in detecting dermatophytes, regardless of sample quality. On the other hand, and as expected, optimal samples allowed the identification of a higher number of dermatophytes by conventional mycological diagnosis, compared to non-optimal samples. Finally, we have suggested several strategies for the practical use of such a kit in a medical laboratory for quick pathogen detection. © 2016 Blackwell Verlag GmbH.
Özcan, Çağrı; Sökücü, Sami; Beng, Kubilay; Çetinkaya, Engin; Demir, Bilal; Kabukçuoğlu, Yavuz Selim
2016-10-01
The aim of this study was to compare the radiological and functional results of two different methods of fixation for the correction of femoral valgus deformities. Patients who had undergone osteotomy and correction of a valgus deformity from 2007 to 2013 were prospectively followed. Thirty three patients (20 females, 13 males) with 39 lower limbs were included in the study. Seventeen lower limbs were treated with retrograde intramedullary nailing (IMN) and 22 with less invasive stabilization system plating. Standing orthoroentgenograms of the lower limbs were taken pre-operatively and at the final follow-up. mLDFA, aLDFA, mechanical axis deviation (MAD) were measured in this orthoroentgenograms. Knee osteoarthritis outcome score (KOOS) and knee range of motion were used pre-operatively and at the final follow-up as part of the evaluation of the clinical results. All patients duration of surgery, length of hospital stay were assessed. Operations were performed by two orthopedic surgeons. The choice of correction method for each patient was determined by the surgeon. Pre-operative and post-operative values were simultaneously measured by two additional orthopedic surgeons. The mean age of the patients was 26.2 years (18.0-51.0) in the plating group and 29.3 years (18.0-55.0) in the nailing group. Patients in the plating and nailing groups were followed up for 24.0 (12.0-60.0) and 27.8 (12.0-60.0) months. All patients were followed for a minimum of 12 months. No significant differences were observed between the groups in terms of age, sex, or duration of follow-up (p > 0.05) Comparison of the pre- and post-operative mLDFA, aLDFA, MAD, length of hospital stay, and duration of surgery between the plating group and nailing group, no significant difference was observed between the groups (p > 0.05). However, patients treated with retrograde IMN had significantly better post-operative results in terms of the KOOS and range of motion of the knee according to plating group (p < 0.05). Retrograde IMN does not provide a radiological advantage over the LISS plating technique for valgus deformity but retrograde IMN and correction offered better functional results in cases of femoral valgus deformity than did the LISS plating method.
Zhou, Bing Rong; Lu, Yan; Permatasari, Felicia; Huang, He; Li, Jin; Liu, Juan; Zhang, Jia An; Luo, Dan; Xu, Yang
2016-11-01
To evaluate the efficacy of fractional carbon dioxide (CO2) laser combined with luliconazole 1% cream for the treatment of onychomycosis and to compare it with that of fractional CO2 laser alone. This was a randomized, parallel group, 2-arm, positive-controlled, single-center, superiority trial with a 1:2 allocation ratio. Sixty patients with clinical and mycological diagnosis of onychomycosis were enrolled from the Dermatology Department of the First Affiliated Hospital of Nanjing Medical University in Nanjing, China from March 2015 to May 2015. Patients were randomized following simple randomization procedures (computerized random number generator) into 2 groups; L group only received 12 sessions of laser treatment at 2-week interval for 6 months, while L + D group received 12 sessions of laser treatment at 2-week interval combined with luliconazole 1% cream once daily for 6 months. This was not a blind trial. The main outcome measures were the clinical efficacy rate (CER) assessed from the percentage of fully and >60% normal-appearing nails and the mycological clearance rate (MCR) assessed from the percentage of nails with negative fungal microscopy. There were no changes to trial outcome measures after the trial commenced. A total of 60 patients (N = 233 nails) completed treatments and follow-up, and were randomized and divided into 2 groups: L group (31 patients, N = 108 nails) and L + D group (29 patients, N = 115 nails). The CER and MCR of L + D group were 69.6% and 57.4%, respectively. L + D group showed significantly higher CER (69.6% vs 50.9%; χ = 8.1, P = 0.004) and MCR (57.4% vs 38.9%; χ = 7.6, P = 0.006) compared with those in L group. Some patients experienced mild pain during laser treatment, but there was no bleeding or oozing during or after treatment. There were no adverse effects reported during the observation period. Fractional CO2 laser treatment combined with 1% luliconazole cream for 6 months was an effective and safe method for the treatment of onychomycosis, and had a higher efficacy than fractional CO2 laser treatment alone.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-24
... shaft length up to 12 inches. Certain steel nails include, but are not limited to, nails made of round... finishes, heads, shanks, point types, shaft lengths and shaft diameters. Finishes include, but are not... collated with adhesive or polyester film tape backed with a heat seal adhesive. Also excluded from the...
John J. Janowiak; Robert H. Falk; Brad A. Gething; John A. Tsirigotis
2014-01-01
This study determined the mechanical properties of nail-laminated (nail-lam) posts manufactured from reclaimed chromated copper arsenate (CCA)âtreated decking lumber. Though CCA-treated lumber is no longer accepted for use in residential applications, it is permitted in agricultural and industrial applications where health and environmental impacts are deemed to be...
Torga-Spak, Roger; Gugala, Zbigniew; Lindsey, Ronald W
2006-03-01
We present a case report of a patient who had a transverse subtrochanteric femur fracture develop 2 months after uneventful placement of a long femorotibial intramedullary nail for knee arthrodesis. To date, diaphyseal fracture of a femur already stabilized with an intramedullary nail has not been reported. The possible etiology for this unusual complication is discussed.
Extraction of the Wichita Fusion Nail after Knee Arthrodesis.
Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose
2016-01-01
To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary.
Attic Retrofits Using Nail-Base Insulated Panels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, David; Kochkin, Vladimir
This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.
[Tibio-talo-calcaneal arthrodesis by retrograde intramedullary nail--a case report].
Lipiński, Łukasz; Synder, Marek; Sibiński, Marcin
2011-01-01
We described a case of 64 year old overweight women, who was treated with revision tibio-talo-calcaneal artrodesis with the use of retrograde intramedullary nail. The procedure was performed after failed primary arthrodesis with the use of lateral approach and fibula osteotomy. Stabilization with intramedullary nail gave good clinical and functional result with a good bone healing.
ERIC Educational Resources Information Center
Moritz, Steffen; Treszl, Andras; Rufer, Michael
2011-01-01
Nail-biting is currently classified as an impulse control disorder not otherwise specified. Although seldom targeted as a primary symptom, nail-biting is often associated with somatic complications and decreased quality of life. The present study assessed the effectiveness of an innovative self-help technique, titled decoupling (DC). DC aims at…
Knee arthrodesis with the Wichita fusion nail.
Domingo, L J; Caballero, M J; Cuenca, J; Herrera, A; Sola, A; Herrero, L
2004-02-01
We reviewed 32 patients who all had knee arthrodesis performed after failed knee replacement. The minimum clinical follow-up was 1 year. The arthrodesis was performed by means of the Wichita fusion nail in 11, by external fixation in 15 cases, by plating in three and by intramedullary nailing in three. The mean patient age was 68.6 years. When the Wichita nail was used, fusion was achieved in ten out of 11 cases after a mean period of 4.5 (3-7) months. Of the remaining 21 patients, fusion was only achieved in 11 cases after a mean period of 6.5 (4.5-10) months.
[Onychocola canadensis Sigler in onychomycosis : A new dermatophyte-like mould in Germany].
Nenoff, P; Schorlemmer, B; Uhrlaß, S; Baunacke, A; Baunacke, A; Friedrichs, C; Iffländer, J; Syhre, E; Schneider, A; Krüger, C; Maier, T
2016-09-01
Moulds or non-dermatophyte moulds (NDM) are being increasingly isolated as causative agent of onychomycoses. Known causes of a NDM-OM are Scopulariopsis brevicaulis, Fusarium, Aspergillus, Acremonium, Neoscytalidium dimidiatum, Arthrographis kalrae, and Chaetomium. In this article, 5 patients with suspected nail infection due to Onychocola canadensis are reported for the first time in Germany. Systemic antifungal agents are not considered to be effective in NDM onychomycosis. In individual cases, however, terbinafine seems to be effective in Onychocola canadensis infection of the nails. Treatment of choice represents, however, nontraumatic nail avulsion using 40 % urea ointment followed by antifungal nail lacquer with ciclopirox olamine or amorolfine.
Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge
2012-01-01
Methylmethacrylate was first reported in 1941 as a cause of contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and industry have been reported, but few reports are found in the literature as a consequence of the contact with sculptured artificial acrylic nails which are increasingly popular. We describe here 3 patients with contact allergy to acrylates in artificial sculptured nails. Patch tests were performed with the Portuguese baseline series of contact allergens and an extended series of acrylates were applied. In particular, we tested three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one presented only with face and eyelid dermatitis had no other lesions. The tests showed positive reaction to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in all the three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic sculptured nails. They show the need to warn patients of persistent and sometimes permanent side effects of these products. They also emphasize the importance of cosmetic ingredient labeling. PMID:25386316
[Scabies of the nail unit in an infant].
Finon, A; Desoubeaux, G; Nadal, M; Georgescou, G; Baran, R; Maruani, A
2017-05-01
There are no guidelines regarding the management of scabies in infants and recurrence is common at this age. We report the case of an infant with subungual hyperkeratosis and ungual lesions subsequent to classic scabies. A 7-month-girl, treated 6 weeks earlier with esdepallethrin for scabies, consulted for acquired lesions on 3 toe nails. These nails were thickened and displayed subungual hyperkeratosis. Physical examination of the skin, the finger nails and mucous membranes was otherwise normal. Fungal analyses were negative, but direct microscopic examination revealed numerous larvae of Sarcoptes scabiei as well as ovular debris. The child was treated with urea 40% to obtain chemical avulsion of the nails, and with topical esdepallethrin and a quarter tablet of ivermectin orally; there was no follow-up of the child. Ungual scabies has already been reported in crusted scabies and very rarely in classic scabies. Subungual and ungual locations of S. scabiei may constitute a source of reinfestation with scabies in infants. Treatment is not well defined and currently involves chemical avulsion of the nails and the application of topical antiscabies treatment. Copyright © 2016. Published by Elsevier Masson SAS.
Epithelium-Derived Wnt Ligands Are Essential for Maintenance of Underlying Digit Bone.
Takeo, Makoto; Hale, Christopher S; Ito, Mayumi
2016-07-01
Clinically, many nail disorders accompany bone deformities, but whether the two defects are causally related is under debate. To investigate the potential interactions between the two tissue types, we analyzed epithelial-specific β-catenin-deficient mice, in which nail differentiation is abrogated. These mice showed regression of not only the nail plate but also of the underlying digit bone. Characterization of these bone defects revealed active bone resorption, which is suppressed by Wnt activation in osteoblast and osteoclast precursors. Furthermore, we found that Wntless expression, essential for Wnt ligand secretion, was lacking in the β-catenin-deficient nail epithelium and that genetic deletion of Wntless (Wls) in the nail epithelium led to the lack of Wnt activation in osteoblast and osteoclast precursors and subsequently led to defective regression of the underlying digit bone. Together, these data show that epithelial Wnt ligands can ultimately regulate Wnt signaling in osteoblast and osteoclast precursors, known to regulate bone homeostasis. These results reveal a critical role for the nail epithelium on the digit bone during homeostatic regeneration and show that Wnt/β-catenin signaling is critical for this interaction. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Buchmueller, Karen L; Staples, Andrew M; Uthe, Peter B; Howard, Cameron M; Pacheco, Kimberly A O; Cox, Kari K; Henry, James A; Bailey, Suzanna L; Horick, Sarah M; Nguyen, Binh; Wilson, W David; Lee, Moses
2005-01-01
Polyamides containing an N-terminal formamido (f) group bind to the minor groove of DNA as staggered, antiparallel dimers in a sequence-specific manner. The formamido group increases the affinity and binding site size, and it promotes the molecules to stack in a staggered fashion thereby pairing itself with either a pyrrole (Py) or an imidazole (Im). There has not been a systematic study on the DNA recognition properties of the f/Py and f/Im terminal pairings. These pairings were analyzed here in the context of f-ImPyPy, f-ImPyIm, f-PyPyPy and f-PyPyIm, which contain the central pairing modes, -ImPy- and -PyPy-. The specificity of these triamides towards symmetrical recognition sites allowed for the f/Py and f/Im terminal pairings to be directly compared by SPR, CD and DeltaT (M) experiments. The f/Py pairing, when placed next to the -ImPy- or -PyPy- central pairings, prefers A/T and T/A base pairs to G/C base pairs, suggesting that f/Py has similar DNA recognition specificity to Py/Py. With -ImPy- central pairings, f/Im prefers C/G base pairs (>10 times) to the other Watson-Crick base pairs; therefore, f/Im behaves like the Py/Im pair. However, the f/Im pairing is not selective for the C/G base pair when placed next to the -PyPy- central pairings.
Nair, Anroop B; Singh, Kishan; Shinu, Pottathil; Harsha, Sree; Al-Dhubiab, Bandar E
2013-05-01
Treatment of nail diseases by topical drug delivery continues to draw much attention in the recent days. This study aims to systematically investigate the effect of constant voltage iontophoresis in the transungual drug delivery, using ciclopirox as a model drug. Preliminary permeation studies were carried out by applying constant voltage (6 V for 24 h) using a gel formulation across the human nail plate in a Franz diffusion cell. Different protocols have been studied to authenticate the potential of the proposed technique. Antifungal studies were carried out to assess the pharmacodynamic effect of drug depot formed in the nail plate. Initial studies revealed that application of constant voltage iontophoresis enhanced the permeation by an order of magnitude (p = 0.019) and delivered significant amount of drug into the deeper nail layers. Noticeably higher permeation was observed during the active phase in on-off studies. Excellent correlation was observed in permeation (r(2) = 0.98) and drug load (r(2) = 0.97) with the increase in applied voltage (3-12 V), indicating that the current technique is predictable. The data observed suggest that any further increase in voltage could eventually lead to increase in the permeation and drug load, as the saturation level is very distant. Furthermore, the enhancement in permeation with the applied voltage (3-12 V) was found to be 6-20 folds, compared to the passive process. Results of step up and step down studies substantiated the viability of the current technique. Zone of inhibition measured during the antifungal studies demonstrated that the drug molecules loaded into the nail plate by low voltage iontophoresis is active and releases over an extended period of time (~32 days). Given the excellent results, the current technique could be used as an effective approach for the delivery of antimycotics, which would localize the drug at the infection site and potentially offer higher patient compliance.
Kuhl, Mitchell; Beimel, Claudia
2016-10-01
The goal of this study was to evaluate the ability of a novel computer assisted surgery system to guide ideal placement of a lag screw during cephalomedullary nailing and then accurately measure the tip-apex distance (TAD) measurement intraoperatively. Retrospective case review. Level II trauma hospital. The initial 98 consecutive clinical cases treated with a cephalomedullary nail in conjunction with a novel computer assisted surgery system were retrospectively reviewed. A novel computer assisted surgery system was utilized to enhance lag screw placement during cephalomedullary nailing procedures. The computer assisted surgery system calculates the TAD intraoperatively after final lag screw placement. The ideal TAD was considered to be within a range of 5mm-20mm. The ability of the computer assisted surgery system (CASS) to assist in placement of a lag screw within the ideal TAD was evaluated. Intraoperative TAD measurements provided by the computer assisted surgery system were then compared to standard postoperative TAD measurements on PACS (picture archiving and communication system) images to determine whether these measurements are equivalent. 79 cases (80.6%) were available with complete information for a retrospective review. All cases had CASS TAD and PACS TAD measurements >5mm and<20mm. In addition, no significant difference could be detected between the intraoperative CASS TAD and the postoperative PACS TAD (p=0.374, Wilcoxon Test; p=0.174, paired T-Test). A cut-out rate of 0% was observed in all patients who were treated with CASS in this case series (95% CI: 0 - 3.01%). The novel computer assisted surgery system tested here is an effective and reliable adjunct that can be utilized for optimal lag screw placement in cephalomedullary nailing procedures. The computer assisted surgery system provides an accurate intraoperative TAD measurement that is equivalent to the standard postoperative measurement utilizing PACS images. Therapeutic Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Residue of organic fluorine pollutants in hair and nails collected from Tianjin].
Yao, Dan; Zhang, Hong; Chai, Zhi-Fang; Shen, Jin-Can; Yang, Bo; Wang, Yan-Ping; Liu, Guo-Qing
2013-02-01
In order to explore the residue and distributions of organic fluorine pollutants in hair and nails, the residue levels of total fluorine (TF), extractable organic fluorine (EOF) and perfluorinated chemicals (PFCs) in hair and nails collected from Tianjin adults were measured by the cyclic neutron activation analysis (CNAA) combined with the high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The results showed that inorganic fluorine (mean: 2.0 mg.kg-1, 4.5 mg.kg-1) was the primary fluorine in TF while EOF(mean: 0.7 mg.kg-1, 1.8 mg.kg-1) was minor. The average amount of identified fluorine (IF) was 0.038 mg.kg-1 in hair and 0.047 mg.kg-1 in nails, accounting or 7.1% (2.6%-16%) and 3.5% (1.1%-11%) of EOF, respectively, which indicated that more than 84% of EOF was unknown. The major residue in hair and nails were medium-and short-chain PFCs,in which perfluorooctane sulfonate, perfluorooctanoic acid and perfluorononanoic acid were the main species. TF, EOF and IF levels in dyed and permed hair were significantly higher than untreated hair (P <0.05), and the concentrations of Sigma PFCs in hair and nails showed no difference between genders. With significantly higher levels of sigma PFCs and PFOS residues than hair (P <0.01), nails could potentially become a more sensitive bioindicator for the exposure level of PFCs in human.
Risk and predictors of fatigue after infectious mononucleosis in a large primary-care cohort.
Petersen, I; Thomas, J M; Hamilton, W T; White, P D
2006-01-01
Fatigue has been found to complicate infectious mononucleosis (IM) when patients are directly asked about it. We do not know whether such fatigue is clinically significant, nor whether IM is a specific risk for fatigue (or whether it can follow other common infections). Various risk markers for post-infectious fatigue have been identified, but findings are inconsistent. To determine the risk of clinically reported fatigue (compared with depression) after IM (compared with both influenza and tonsillitis) in patients attending primary care, and to examine risk markers for post-IM fatigue. Comparison of matched primary-care cohorts. We identified 1438 adult patients with a positive heterophil antibody test for IM from the UK General Practice Research Database. These patients were individually matched on age, sex and practice to two comparison groups; one with a clinical diagnosis of influenza and the other of tonsillitis. The odds ratios (ORs) (95%CI) for reported fatigue after IM vs. influenza and tonsillitis were 4.4 (2.9-6.9) and 6.6 (4.2-10.4), respectively. Risk markers for post-IM fatigue included female sex and premorbid mood disorder. By comparison, the ORs for depression after IM vs. influenza and tonsillitis were 1.6 (0.9-2.6) and 2.3 (1.4-3.9), respectively. IM is a specific and significant risk for clinically reported fatigue, which is both separate from, and more common than, depression. Female sex and premorbid mood disorder are risk markers for fatigue. These can be used both to target prevention strategies and to explore aetiological mechanisms.
Cation symmetry effect on the volatility of ionic liquids.
Rocha, Marisa A A; Coutinho, João A P; Santos, Luís M N B F
2012-09-06
This work reports the first data for the vapor pressures at several temperatures of the ionic liquids, [C(N/2)C(N/2)im][NTf(2)] (N = 4, 6, 8, 10, 12) measured using a Knudsen effusion apparatus combined with a quartz crystal microbalance. The morphology and the thermodynamic parameters of vaporization derived from the vapor pressures, are compared with those for the 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide series, [C(N-1)C(1)im][NTf(2)] (N = 3 - 9, 11, and 13). It was found that the volatility of [C(N/2)C(N/2)im][NTf(2)] series is significantly higher than the asymmetric cation ILs with the same total number of carbons in the alkyl side chains, [C(N-1)C(1)im][NTf(2)]. The observed higher volatility is related with the lower enthalpy of vaporization. The symmetric cation, [C(N/2)C(N/2)im][NTf(2)], presents lower entropies of vaporization compared with the asymmetric [C(N-1)C(1)im][NTf(2)], indicating an increase of the absolute liquid entropy in the symmetric cation ILs, being a reflection of a change of the ion dynamics in the IL liquid phase. Moreover both the enthalpy and entropy of vaporization of the [C(N/2)C(N/2)im][NTf(2)] ILs, present a clear odd-even effect with higher enthalpies/entropies of vaporization for the odd number of carbons in each alkyl chain ([C(3)C(3)im][NTf(2)] and [C(5)C(5)im][NTf(2)]).
Properties of three graphite/toughened resin composites
NASA Technical Reports Server (NTRS)
Smith, Donald L.; Dow, Marvin B.
1991-01-01
Results are presented from an experimental evaluation of IM7/977-2, IM7/F655, and T800/F3900. Data presented include ply-level (unidirectional laminate) strength and moduli, unnotched and notched (open hole) tension and compression properties of quasi-isotropic laminates, and compression-after-impact strengths. These data are compared with properties of other toughened (IM7/8551-7 and IM6/18081) and brittle (T300/5208) graphite-epoxy materials. The IM7/977-2, IM7/F655, and T800/F3900 materials are substantially stronger and more damage tolerant than widely used first generation composite materials such as T300/5208. The T800/F3900 outperforms IM7/977-2 and IM7/F655 materials in tolerance to projectile impacts. Compression-after-impact strengths were found to be dependent on impactor velocity for a given impact energy. The open hole compression properties of all three materials are degraded by the combination of heat and moisture.
NASA Technical Reports Server (NTRS)
Paris, H. G.; Chellman, D. J.
1986-01-01
The advantages of rapid solidification processing over ingot metallurgy processing in the development of 2XXX aluminum alloy compositions were evaluated using a similarly processed ingot metallurgy (IM) control alloy. The powder metallurgy (PM) alloy extrusions showed a reduced age-hardening response in comparison with similar IM compositions, with higher tensile properties for naturally aged extrusions but lower properties for artificially aged ones. However, the tensile properties of naturally and artificially aged PM alloy extrusions based on a version of IM 2034 alloy, but containing 0.6 weight percent zirconium, were comparable to those of the IM control extrusions and had significantly superior combinations of strength and toughness. The tensile properties of this PM alloy showed even greater advantage in 6.4-mm (0.25-in.) and 1.8-mm (0.070-in.) plate and sheet, the yield strength being about 68 MPa (10 ksi) greater than reported values for the IM 2034 alloy sheet. An artificially aged PM alloy based on 2219 alloy also showed a strength and strength-toughness combination comparable to those of the PM Al-Cu-Mg-Zr alloy, substantially outperforming the IM 2219 alloy. These results show that rapid solidification offers the flexibility needed to modify conventional IM compositions to produce new alloy compositions with superior mechanical properties.
Zinc(II)-methimazole complexes: synthesis and reactivity.
Isaia, Francesco; Aragoni, Maria Carla; Arca, Massimiliano; Bettoschi, Alexandre; Caltagirone, Claudia; Castellano, Carlo; Demartin, Francesco; Lippolis, Vito; Pivetta, Tiziana; Valletta, Elisa
2015-06-07
The tetrahedral S-coordinated complex [Zn(MeImHS)4](ClO4)2, synthesised from the reaction of [Zn(ClO4)2] with methimazole (1-methyl-3H-imidazole-2-thione, MeImHS), reacts with triethylamine to yield the homoleptic complex [Zn(MeImS)2] (MeImS = anion methimazole). ESI-MS and MAS (13)C-NMR experiments supported MeImS acting as a (N,S)-chelating ligand. The DFT-optimised structure of [Zn(MeImS)2] is also reported and the main bond lengths compared to those of related Zn-methimazole complexes. The complex [Zn(MeImS)2] reacts under mild conditions with methyl iodide and separates the novel complex [Zn(MeImSMe)2I2] (MeImSMe = S-methylmethimazole). X-ray diffraction analysis of the complex shows a ZnI2N2 core, with the methyl thioethers uncoordinated to zinc. Conversely, the reaction of [Zn(MeImS)2] with hydroiodic acid led to the formation of the complex [Zn(MeImHS)2I2] having a ZnI2S2 core with the neutral methimazole units S-coordinating the metal centre. The Zn-coordinated methimazole can markedly modify the coordination environment when changing from its thione to thionate form and vice versa. The study of the interaction of the drug methimazole with the complex [Zn(MeIm)4](2+) (MeIm = 1-methylimidazole) - as a model for Zn-enzymes containing a N4 donor set from histidine residues - shows that methimazole displaces only one of the coordinated MeIm molecules; the formation constant of the mixed complex [Zn(MeIm)3(MeImHS)](2+) was determined.
Wukich, Dane K.; Mallory, Brady R.; Suder, Natalie C.; Rosario, Bedda L.
2017-01-01
Retrograde intramedullary nailing for tibiotalocalcaneal arthrodesis is a salvage procedure reserved for severe cases of deformity. The aim of the present study was to compare the outcomes of this technique in patients with and without diabetes mellitus (DM). A total of 61 patients with and 56 without DM underwent retrograde intramedullary nailing and had a minimum follow-up period of 12 months. The overall incidence of complication was 45.2%; however, the overall incidence of complications between those with and without DM was not significantly different (odds ratio [OR] 0.79, 95% confidence interval [CI] 0.38 to 1.65, p = .54). Patients with DM had a significantly greater rate of superficial infections (OR 8.3, 95% CI 1.01 to 68.67, p = .03). However, no difference was seen in the rate of deep infection (OR 0.90, 95% CI 0.34 to 2.46, p = .83) or noninfectious complications (OR 0.50, 95% CI 0.23 to 1.13, p = .09). Successful limb salvage was achieved for 96.8% of the patients with DM and 94.7% of those without DM (p = .66). A femoral head allograft was used in 32 (27.4%) of 117 patients to substitute for an osseous void. Of the 32 patients who required a femoral head allograft, 21 (67.7%) experienced a complication compared with 32 (37.6%) of 85 patients who did not require a femoral head allograft (OR 3.16, 95% CI 1.35 to 7.41, p = .008). The incidence of patient satisfaction was 80% for patients with DM and 72% for those without DM (p = .36). Despite a high incidence of complications, limb salvage was accomplished in approximately 95% of patients with complicated deformities. Four patients (6.56%) with DM experienced a tibia fracture; therefore, we now routinely use a 300-mm-long nail for this reconstruction. PMID:26015305
Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming
2013-12-17
To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.
Extraction of the Wichita Fusion Nail after Knee Arthrodesis
Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose
2016-01-01
To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary. PMID:28529847
Exposure test of fasteners in preservative-treated wood
Samuel L. Zelinka; Douglas R. Rammer
2006-01-01
This study examined nails and screws exposed to ACQ-treated wood for up to 12 months in a controlled environment. The environment (27ºC, 100% relative humidity) was chosen so that comparisons could be made with previous exposure tests run using CCA-treated wood in the same environment. Five types of fasteners (common 8d nail, hot-dipped galvanized 8d nail, 4d aluminum...
Chang, Carina; Beutler, Bryce D; Cohen, Philip R
2017-06-01
Redness of the nail plate-erythronychia-is a common condition involving one or multiple digits. It may affect the entire nail or present as longitudinal red bands that extend from the proximal nail fold to the distal tip of the nail plate. Rarely, red bands may traverse the nail bed horizontally. Although erythronychia is often idiopathic, it has also been associated with amyloidosis, Darier's disease, lichen planus, and various other cutaneous conditions. We describe the clinical features of a 64-year-old Caucasian man who presented with transverse and longitudinal erythronychia affecting his fingernails. In addition, we review the classification of erythronychia and summarize the acute and chronic conditions that have been associated with this clinical finding. The features of a man with polydactylous transverse and longitudinal erythronychia are presented. In addition, PubMed was used to search the following terms: erythronychia, longitudinal erythronychia, red lunulae, and subungual. All papers were reviewed, and relevant articles, along with their references, were evaluated. Informed consent was obtained from the patient for being included in the study. A 64-year-old Caucasian man with a past medical history significant for testicular cancer and pulmonary embolism presented with multiple horizontal pink-red bands affecting his fingernails. The discoloration was most prominent in the region distal to the lunula. In addition, the nails of the fifth digit of his left hand and third digit of his right hand featured longitudinal red bands extending from the distal curvature of the lunula to the free edge of the nail plate. A diagnosis of polydactylous longitudinal and transverse erythronychia, based on the clinical presentation, was established. Our patient's red bands were asymptomatic and he was not concerned about the cosmetic appearance of his nails; therefore, no additional investigation or treatment was required. Polydactylous transverse erythronychia is a rare condition characterized by the development of horizontal red bands affecting the fingernails or toe nails. It has only been previously described in a man with multiple system atrophy. In our patient, both transverse and longitudinal red bands were present simultaneously. Therefore, it is possible that horizontal erythronychia is an early clinical manifestation of longitudinal erythronychia.
Reinhardt, Sophia; Martin, Heiner; Ulmar, Benjamin; Döbele, Stefan; Zwipp, Hans; Rammelt, Stefan; Richter, Martinus; Pompach, Martin; Mittlmeier, Thomas
2016-08-01
Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. Both minimally invasive interlocking nail systems displayed a high primary stability that was not inferior to an interlocking plate. Based on our results, both interlocking nails appear to represent a viable option for treating displaced intra-articular calcaneal fractures. © The Author(s) 2016.
[Design of Minimal Invasive Screw on Posterior Pelvis Ring and Pelvic Finite Element Analysis].
Tang, Fan; Min, Li; Wang, Yan-Ling; Qu, Bo; Zhou, Yong; Luo, Yi; Zhang, Wen-Li; Shi, Rui; Duan, Hong; Tu, Chong-Qi
2017-09-01
To design minimal invasive screw on posterior pelvic ring and perform threedimensional finite element analysis based on a pelvis finite element model. We measured the pelvic anatomical data of 20 healthy volunteers and identified potential designs for minimal invasive screw on posterior pelvic ring. A finite element model of pelvis was then established. Threedimensional finite element analyses were performed under static and dynamic mechanical loading,respectively. Three screw tracks on ilium (A,B and C) were identified based on a threedimensional reconstruction of pelvis. Nail track B and C had greater length and width,but shorter distance between nailing and soft tissue compared with nail track A. Static loading under an external rotation load of 500 N generated a maximum Mises Von stress of 582.05 Pa and sacral iliac complex of 107.38 Pa. The greatest strain was located at the articular cartilage on the side of the nail,followed by lateral sacral joint cartilage and symphysis pubis. The largest displacement was located at the ilium on the side of the nail,with a gradient decrease to the opposite side. The largest displacement of the anterior superior iliac spine was 0.35 cm on the side of the nail. The dynamic loading identified displacement of the anterior superior iliac spine with 1.5 mm in Z axis,1.8 mm in X axis and -0.2 mm in Y axis; and displacement of the pubic bone with 0.8 mm in Z axis,1.0 mm in X axis and 0.03 mm in Y axis. The maximum displacement appeared along the impact direction: Y axis. Relatively large equivalent stress was found in pubis and ischium,anterior superior iliac spine,sacrum,acetabular that are prone to fracture. With increased impact force,the stress of pelvis increased over time. The maximum impact force,stress and displacement of the pelvis occurred at 10 ms when peak force was reached. Under the impact of 4 000 N and 5 000 N,the bone was subject to a stress level of over 200 MPa,exceeding its average yield strength,which suggests a possibility of pelvic fracture. Taking B/C as a main screw track and A as an auxiliary screw track is a reasonable choice. The pelvic finite element model lays a foundation for further studies into sacral fracture and design of screw tracks.
Yadav, Pravesh; Singal, Archana; Pandhi, Deepika; Das, Shukla
2015-01-01
Dermatophytes are the most frequently implicated agents in toenail onychomycosis and oral terbinafine has shown the best cure rates in this condition. The pharmacokinetics of terbinafine favors its efficacy in pulse dosing. To compare the efficacy of terbinafine in continuous and pulse dosing schedules in the treatment of toenail dermatophytosis. Seventy-six patients of potassium hydroxide (KOH) and culture positive dermatophyte toenail onychomycosis were randomly allocated to two treatment groups receiving either continuous terbinafine 250 mg daily for 12 weeks or 3 pulses of terbinafine (each of 500 mg daily for a week) repeated every 4 weeks. Patients were followed up at 4, 8 and 12 weeks during treatment and post-treatment at 24 weeks. At each visit, a KOH mount and culture were performed. In each patient, improvement in a target nail was assessed using a clinical score; total scores for all nails and global assessments by physician and patient were also recorded. Mycological, clinical and complete cure rates, clinical effectivity and treatment failure rates were then compared. The declines in target nail and total scores from baseline were significant at each follow-up visit in both the treatment groups. However, the inter-group difference was statistically insignificant. The same was true for global assessment indices, clinical effectivity as well as clinical, mycological, and complete cure rates. The short follow-up in our study may have led to lower cure rates being recorded. Terbinafine in pulse dosing is as effective as continuous dosing in the treatment of dermatophyte toenail onychomycosis.
Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P
2016-10-01
Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.
Cancer incidence following infectious mononucleosis.
Carter, C D; Brown, T M; Herbert, J T; Heath, C W
1977-01-01
By means of a mailed questionnaire, the investigators examined the incidence of cancer among 2282 former college students in whom heterophile-positive infectious mononucleosis (IM) was diagnosed between 1949 and 1969 at five U.S. universities. Cancer incidence among these IM cases was compared both with national incidence rates and with an age and sex-matched group of 2779 non-IM students. No significant increase in cancer incidence was found. Three cases of Hodgkin's disease (HD) had occurred in the IM group (1.3 cases expected) and one case in the control group. All three post-IM cases of HD were in males. Intervals between diagnoses of IM and HD were three, four, and seven years, respectively. Only two other cases of lymphoma or leukemia were observed, and both were in the control group.
Acute and chronic symptoms of mononucleosis.
Lambore, S; McSherry, J; Kraus, A S
1991-07-01
The clinical symptoms and durations of illness of patients with infectious mononucleosis (IM) are variable and are poorly documented in the scientific literature. Patients who presented for care at the Student Health Service of a Canadian university between September 1985 and May 1988 and had been diagnosed as having IM were surveyed. Health experience during the acute and convalescent phases of IM was compared with that of a group of patients matched for age, sex, date of diagnosis, and year of study, who had suffered acute upper respiratory tract infections (URI), other than Epstein-Barr virus (EBV)-induced, during the same period. Students were sicker for longer after IM than after non-EBV-induced URI. During the acute phase of illness, the symptoms of fatigue (P = less than .000001), night sweats (P = .000001), and painful neck swelling (P = .00003) were seen significantly more often in the IM group. The severity and duration of these symptoms were also significantly worse in IM patients. Getting tired easily (P = .002), diurnal somnolence (P = .002), and depression (P = .002) were significantly more common postacute symptoms. Eleven percent of IM patients reported persistence of symptoms longer than 100 days, and in 6% of patients the symptoms had persisted after 1 year. Convalescent cases showed a trend toward reduced alcohol intake and, perhaps, reduced alcohol tolerance. IM involves excessive morbidity in a student community compared with URI that was other than EBV-induced, during both the acute and the postacute phases of infection.
Nail injury to the brain obfuscated by a fall from height - homicide or suicide? a case report.
Aggrawal, Anil; Pradhan, Monisha; Sreenivas, M
2015-01-01
Penetrating head injuries caused by unconventional objects such as a nail generate speculation and doubt regarding the manner of infliction. We report a case of a 24-year-old woman alleged to have committed suicide by a fall from height. Autopsy revealed an unprecedented penetrating intracranial injury caused by a nail over the right temporal region, confounding the manner of death. The underlying intersecting pattern of fractures determined the chronological sequence of events. In this paper, we discuss the manner, incidence and pathology of nail injuries to the brain. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
The use of intramedullary nails in tibiotalocalcaneal arthrodesis.
Thomas, Ruth L; Sathe, Vinayak; Habib, Syed I
2012-01-01
Tibiotalocalcaneal arthrodesis is a salvage procedure undertaken for hindfoot problems that affect both the ankle and subtalar joints (eg, two-joint arthritis, severe acute trauma, osteonecrosis of the talus, severe malalignment deformities, significant hindfoot bone loss). Methods of achieving fusion include Steinmann pins, screws, plates, external fixators, and retrograde intramedullary nailing. Retrograde intramedullary nailing provides a load-sharing fixation device with superior biomechanical properties and is an excellent choice for use in tibiotalocalcaneal arthrodesis. This technique can be performed through relatively small incisions. In addition, recent design modifications include the availability of dynamization and the choice of curved or straight nails. Contraindications to the technique include the presence of infection, severe vascular disease, and severe malalignment of the tibia.
Belangero, William Dias; Santos Pires, Robinson Esteves; Livani, Bruno; Rossi, Felipe Lins; de Andrade, Andre Luis Lugnani
2018-05-01
Treatment of proximal tibial shaft fractures is always challenging. Despite the development of modern techniques, the literature still shows high complication rates, especially regarding proximal fragment malalignment. It is well known that knee position in flexion during tibial nailing is responsible for extension and valgus deformities of the proximal fragment. Unlike in tibial shaft fractures, nails do not reduce proximal tibial fractures due to the medullary canal width. This study aims to describe a simple, useful, and inexpensive technique to prevent valgus and extension deformities when treating proximal tibial fractures using conventional nails: the so-called clothesline technique.
Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.
2013-01-01
Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527
Buchmueller, Karen L.; Staples, Andrew M.; Uthe, Peter B.; Howard, Cameron M.; Pacheco, Kimberly A. O.; Cox, Kari K.; Henry, James A.; Bailey, Suzanna L.; Horick, Sarah M.; Nguyen, Binh; Wilson, W. David; Lee, Moses
2005-01-01
Polyamides containing an N-terminal formamido (f) group bind to the minor groove of DNA as staggered, antiparallel dimers in a sequence-specific manner. The formamido group increases the affinity and binding site size, and it promotes the molecules to stack in a staggered fashion thereby pairing itself with either a pyrrole (Py) or an imidazole (Im). There has not been a systematic study on the DNA recognition properties of the f/Py and f/Im terminal pairings. These pairings were analyzed here in the context of f-ImPyPy, f-ImPyIm, f-PyPyPy and f-PyPyIm, which contain the central pairing modes, –ImPy– and –PyPy–. The specificity of these triamides towards symmetrical recognition sites allowed for the f/Py and f/Im terminal pairings to be directly compared by SPR, CD and ΔTM experiments. The f/Py pairing, when placed next to the –ImPy– or –PyPy– central pairings, prefers A/T and T/A base pairs to G/C base pairs, suggesting that f/Py has similar DNA recognition specificity to Py/Py. With –ImPy– central pairings, f/Im prefers C/G base pairs (>10 times) to the other Watson–Crick base pairs; therefore, f/Im behaves like the Py/Im pair. However, the f/Im pairing is not selective for the C/G base pair when placed next to the –PyPy– central pairings. PMID:15703305
Osteosynthesis of fractures of the femur with flexible metallic intramedullary nails.
Firica, A; Troianescu, O; Petre, M
1978-04-01
The authors discuss their use of Ender's method in the treatment of fractures of the femur. The diameter and length of the nails depends on the type of fracture. 1) Three nails of 4 mm diameter are introduced in parallel from the medial condyle in fractures of the femoral neck; 2) 5 mm nails are used, in similar fashion, for the fixation of intertrochanteric and subtrochanteric fractures; 3) 5 mm nails are used for diaphyseal, supracondylar and intercondylar fractures, introduced in crossed fashion ("Eiffel Tower" technique) from both medial and lateral condyles. This method of fixation has proved to be extremely stable. The operation itself is quick, with no blood loss or shock. The patient can resume partial weight bearing after a week in stabilised intertrochanteric and shaft fractures, after a month in less stable types, and after three to four months in fractures of the neck of the femur. This report is based on the first 250 cases treated by this method.
A Review of Indigo Naturalis as an Alternative Treatment for Nail Psoriasis.
McDermott, Laura; Madan, Raman; Rupani, Reena; Siegel, Daniel
2016-03-01
Nail psoriasis is challenging to treat. The few currently available therapies are limited in efficacy, and often produce unfavorable side effects. A plant extract widely used in Traditional Chinese Medicine, indigo naturalis (Qing Dai), is presented in this review as an alternative topical treatment for skin and nail psoriasis. The purpose of this article is to present information on a viable alternative treatment with a favorable side effect profile for a difficult disease to treat. A PubMed search for the term "indigo naturalis" was performed, and literature from 2006 to the present relevant to indigo naturalis and treatment of psoriasis and nail psoriasis was reviewed. Indigo naturalis shares several therapeutic mechanisms with current psoriasis treatments, such as regulation of keratinocyte proliferation and differentiation, restoration of epidermal barrier function, and reduction of inflammatory processes. Clinically, it is well tolerated. Recent research of indigo naturalis suggests that it is a safe, inexpensive, and effective alternative topical treatment for skin and nail psoriasis.
Complications of tibio-talar-calcaneal fusion using intramedullary nails.
Fenton, P; Bali, N; Matheshwari, R; Youssef, B; Meda, K
2014-12-01
Hindfoot nails are being increasingly used, however significant complications can occur. The purpose of this study was to assess the complications following the use of hindfoot nails at our institution. We identified patients from a retrospective database. All underwent hindfoot nailing under the care of the senior author. Details of complications were recorded. We identified 52 patients undergoing 55 procedures. Mean follow up was 44.8 months (18-69). Forty patients achieved ankle fusion and 36 subtalar joint fusion. Complications included prominent metalwork in 13 patients, CRPS in five and one peri-prosthetic fracture. Nine developed deep infection, and of these limb salvage was achieved in six patients by removal of metalwork, debridement and insertion of antibiotic loaded cement beads. The remaining three patients underwent below knee amputation. Significant complications can occur, although limb preservation was possible in most cases of deep infection. Hindfoot nailing should be reserved as salvage procedure. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
The SIGN nail for knee fusion: technique and clinical results.
Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M; Feyissa, Abebe Chala
2016-02-05
Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18-50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8-14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options.
Intramedullary knee arthrodesis as a salvage procedure after failed total knee replacement.
Panagiotopoulos, E; Kouzelis, A; Matzaroglou, Ch; Saridis, A; Lambiris, E
2006-12-01
Septic and aseptic loosening with or without extensive bone loss after total knee replacement are the most common indications for knee fusion. Both external fixation and intramedullary nailing can be used for the treatment, though the latter appears to be the method of choice for most patients. Nine patients were treated after a total knee replacement failure using intramedullary nailing. A long intramedullary nail with a proximal interlocking screw was used in five cases, and a customised nail was used in four cases. Successful fusion occurred in eight of nine patients (89%). Average time for the joint union was 6.5 months, and average operative blood loss was 860 ml. In two patients, iliac crest and patellar bone graft were also used. In conclusion, intramedullary nailing can give excellent results in achieving knee fusion after a failed knee replacement as it allows early weight bearing and at the same time offers stability, pain relief, and a high rate of union, even though the surgical technique is demanding.
Mihailovic, Zoran; Savic, Slobodan; Atanasijevic, Tatjana
2007-09-01
An interesting case of firearm suicide carried out using an unusual type of handmade weapon and a peculiar combination of tandem missiles is presented. A nail and a screw were placed in the rifle barrel ahead of a bullet, and all 3 were simultaneously discharged. The inflicted injury began with 1 common channel, which later split in 2 separate channels, both directed backwards and upwards; one was caused by the screw, ending in the epistropheal body, and the other, caused by the bullet and the nail, penetrated into the cranial cavity, where it bifurcated in 2 branches, one from the bullet, ending in the cerebellar tissue, and the other from the nail, penetrated through the brain stem. The established site of the entrance suicidal wound, the appearance of the weapon, and the unusual missiles are discussed with regard to the available references dealing with different types of nail injuries to the head.
Imaging technique for the diagnosis of onychomatricoma.
Cinotti, E; Veronesi, G; Labeille, B; Cambazard, F; Piraccini, B M; Dika, E; Perrot, J L; Rubegni, P
2018-06-05
Onychomatricoma is a rare tumour that derives from the nail matrix and grows within the nail plate. The clinical presentation can mimic many other tumours and conditions, and surgical biopsy and histopathological examination are necessary to confirm the diagnosis. As nail surgery is a painful experience for the patient and sometimes can leave permanent onychodistrophy, more precise preoperative diagnosis is needed to distinguish onychomatricoma from other nail diseases more accurately and to limit surgical interventions. The objective of this study was to evaluate current literature on imaging techniques for the diagnosis of onychomatricoma in order to understand how this technology can help the presurgical diagnosis of this tumour. We searched in the Cochrane Skin Group Specialised library, Medline, Embase and LILACS databases all studies evaluating imaging technique for the diagnosis of onychomatricoma up to February 2018. We found that not only nail dermoscopy, but also reflectance confocal microscopy, optical coherence tomography, ultrasonography and magnetic resonance can be useful in this field. © 2018 European Academy of Dermatology and Venereology.
An electrochemical modeling of lithium-ion battery nail penetration
NASA Astrophysics Data System (ADS)
Chiu, Kuan-Cheng; Lin, Chi-Hao; Yeh, Sheng-Fa; Lin, Yu-Han; Chen, Kuo-Ching
2014-04-01
Nail penetration into a battery pack, resulting in a state of short-circuit and thus burning, is likely to occur in electric car collisions. To demonstrate the behavior of a specific battery when subject to such incidents, a standard nail penetration test is usually performed; however, conducting such an experiment is money consuming. The purpose of this study is to propose a numerical electrochemical model that can simulate the test accurately. This simulation makes two accurate predictions. First, we are able to model short-circuited lithium-ion batteries (LIBs) via electrochemical governing equations so that the mass and charge transfer effect could be considered. Second, the temperature variation of the cell during and after nail penetration is accurately predicted with the help of simulating the temperature distribution of thermal runaway cells by thermal abuse equations. According to this nail penetration model, both the onset of battery thermal runaway and the cell temperature profile of the test are obtained, both of which are well fitted with our experimental results.
Nail-fold excision for the treatment of ingrown toenail in children.
Haricharan, Ramanath N; Masquijo, Javier; Bettolli, Marcos
2013-02-01
To evaluate the effectiveness of the nail-fold excision procedure in children. Prospectively collected data on patients less than 18 years of age who underwent a nail-fold excision for symptomatic ingrown toenail were analyzed. Patients were seen in 2 centers and data collected included demographics, site of ingrown toenail, complications (including recurrence), patient satisfaction, and duration of follow-up. Overall, 67 procedures were performed on 50 patients between June 2009 and July 2011 at the 2 institutions. The mean age was 14 years (range, 9-18 years) and 30 were male patients. No recurrences were seen after a follow-up for a median of 14 months (range 6-28 months). Patients were very satisfied with the cosmetic outcomes. Six minor complications occurred, including 3 patients with bleeding requiring dressing change, 2 with excessive granulation tissue, and 1 with nail growth abnormality. The nail-fold excision technique is highly effective in the pediatric population, with no recurrence, excellent cosmesis, and very high patient satisfaction. Copyright © 2013 Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ashraf Mohamad Ismail, Mohd; Ng, Soon Min; Hazreek Zainal Abidin, Mohd; Madun, Aziman
2018-04-01
The application of geophysical seismic refraction for slope stabilization design using soil nailing method was demonstrated in this study. The potential weak layer of the study area is first identify prior to determining the appropriate length and location of the soil nail. A total of 7 seismic refraction survey lines were conducted at the study area with standard procedures. The refraction data were then analyzed by using the Pickwin and Plotrefa computer software package to obtain the seismic velocity profiles distribution. These results were correlated with the complementary borehole data to interpret the subsurface profile of the study area. It has been identified that layer 1 to 3 is the potential weak zone susceptible to slope failure. Hence, soil nails should be installed to transfer the tensile load from the less stable layer 3 to the more stable layer 4. The soil-nail interaction will provide a reinforcing action to the soil mass thereby increasing the stability of the slope.
Harper, Brett; Neumann, Elizabeth K; Stow, Sarah M; May, Jody C; McLean, John A; Solouki, Touradj
2016-10-05
Ion mobility (IM) is an important analytical technique for determining ion collision cross section (CCS) values in the gas-phase and gaining insight into molecular structures and conformations. However, limited instrument resolving powers for IM may restrict adequate characterization of conformationally similar ions, such as structural isomers, and reduce the accuracy of IM-based CCS calculations. Recently, we introduced an automated technique for extracting "pure" IM and collision-induced dissociation (CID) mass spectra of IM overlapping species using chemometric deconvolution of post-IM/CID mass spectrometry (MS) data [J. Am. Soc. Mass Spectrom., 2014, 25, 1810-1819]. Here we extend those capabilities to demonstrate how extracted IM profiles can be used to calculate accurate CCS values of peptide isomer ions which are not fully resolved by IM. We show that CCS values obtained from deconvoluted IM spectra match with CCS values measured from the individually analyzed corresponding peptides on uniform field IM instrumentation. We introduce an approach that utilizes experimentally determined IM arrival time (AT) "shift factors" to compensate for ion acceleration variations during post-IM/CID and significantly improve the accuracy of the calculated CCS values. Also, we discuss details of this IM deconvolution approach and compare empirical CCS values from traveling wave (TW)IM-MS and drift tube (DT)IM-MS with theoretically calculated CCS values using the projected superposition approximation (PSA). For example, experimentally measured deconvoluted TWIM-MS mean CCS values for doubly-protonated RYGGFM, RMFGYG, MFRYGG, and FRMYGG peptide isomers were 288.8 Å(2), 295.1 Å(2), 296.8 Å(2), and 300.1 Å(2); all four of these CCS values were within 1.5% of independently measured DTIM-MS values. Copyright © 2016 Elsevier B.V. All rights reserved.
Filardi, Vincenzo
2015-01-01
Aims The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. Unreamed nailing favours biology at the expense of the achievable mechanical stability, it is therefore of interest to define the limits of the clinical indications for this method. Extra-articular fractures of the distal tibial metaphysis, meta-diaphyseal junction, and adjacent diaphysis are distinct in their management from impaction derived ‘‘pilon’’ type fractures and mid-diaphyseal fractures. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bones in a fractured tibia. With this purpose a complete model of the human leg was realised, simulating a mid-diaphyseal fracture, classified as A2 type 1, according to the AO classification. The analysis of the entire chain allows to have a complete picture of the stress distribution and of the most stressed bones and soft tissues, but, more importantly can overcome problems connected with boundary conditions imposed at single bony components. Methods Model consists of six bony structures: pelvis, femur, patella, fibula, tibia, and a simplified lump of the feet, configured in a standing up position. Their articular cartilage layers, were simulated by 3D membranes of opportune stiffness connecting the different segments. Moreover an unreamed intra-medullary nail Expert Tibial Nail (DePuy Synthes®) stabilized the fractured tibia. A load of 700 N has been applied at the top of pelvis and a part the feet, at the tip, was rigidly fixed. Five different contact interfaces have been imposed at the different bony surfaces in contact. Results Three different conditions were analysed: the initially healthy tibia, the A2 type 1 fractured tibia with the Expert tibial nail implanted, and the follow up stage after complete healing of tibia. Non-linear finite element analysis of the models were performed with Abaqus version 5.4 (Hibbitt, Karlsson and Sorensen, Inc., Pawtucket, RI) using the geometric non linearity and automatic time stepping options. Conclusion The obtained results reveal interesting consequences deriving by taking into account how the stress shielding can influence the integrity and resistance of bones, in order to identify the mechanical reasons for the unfavourable clinical results, and to identify borderline indications due to biomechanical factors. The evolution of treatment options for these fractures has been closely linked to developments in implant technology and surgical technique. Further developments in this area, particularly with respect to minimally invasive plating techniques and nail design are ongoing. PMID:26719629
Scanning electron microscopy of superficial white onychomycosis*
de Almeida Jr., Hiram Larangeira; Boabaid, Roberta Oliveira; Timm, Vitor; Silva, Ricardo Marques e; de Castro, Luis Antonio Suita
2015-01-01
Superficial white onychomycosis is characterized by opaque, friable, whitish superficial spots on the nail plate. We examined an affected halux nail of a 20-year-old male patient with scanning electron microscopy. The mycological examination isolated Trichophyton mentagrophytes. Abundant hyphae with the formation of arthrospores were found on the nail's surface, forming small fungal colonies. These findings showed the great capacity for dissemination of this form of onychomycosis. PMID:26560225
Kamath, Atul F; Austin, Daniel; Lee, Gwo-Chin
2012-08-01
Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer mated with an intramedullary nail. The acetabulum was then exposed and the necrotic cartilage was removed and curetted. The acetabulum was reamed to accept a PROSTALAC acetabular shell. The shell was cemented into the acetabulum with antibiotic cement. The custom-made spacer was then inserted distally first into the tibia. The distal end of the intramedullary nail was interlocked with a bicortical bolt to minimise nail rotation. Antibiotic-impregnated cement was moulded around the nail and spacer. The proximal end of the spacer was then reduced into the acetabular socket, and the joint was irrigated and the wound closed. A customised abduction brace was fitted, and partial weight bearing was allowed. Sufficient leg length, soft-tissue tension, and range of hip motion were restored, and a total femur and constrained liner was re-implanted 4 months later. Mating of an intramedullary nail with a PROSTALAC spacer is a viable reconstructive option.
Advanced concepts in knee arthrodesis.
Wood, Jennifer H; Conway, Janet D
2015-03-18
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty.
Advanced concepts in knee arthrodesis
Wood, Jennifer H; Conway, Janet D
2015-01-01
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty. PMID:25793160
Anderson, Thomas; Linder, Lars; Rydholm, Urban; Montgomery, Fredrik; Besjakov, Jack; Carlsson, Ake
2005-08-01
Arthrodesis of the ankle joint using screws or external fixation is often a demanding procedure, notably in patients with rheumatoid arthritis. We investigated whether tibio-talocalcaneal arthrodesis with the use of an intramedullary nail is a safe and simple procedure. We retrospectively reviewed 25 ankles (25 patients) at median 3 (1-7) years after tibio-talocalcaneal arthrodesis because of rheumatoid arthritis. All had been operated on by retrograde insertion of a retrograde nail. 5 types of nail had been used. Complications, functional outcome scores, and patient satisfaction were determined and the radiographs evaluated for healing. All but 1 ankle had a radiographically healed arthrodesis. We recorded 3 deep infections, all healed--in 2 cases after extraction of the nail--and the arthrodesis healed in all 3 patients. The average functional scores at follow-up were high, considering that the patients suffered from rheumatoid arthritis. 23 patients were satisfied with the outcome. We found a correlation between the functional scores and the general activity of the disease expressed as a Health Assessment Questionnaire score. In patients with rheumatoid arthritis, tibio-talocalcaneal arthrodesis with a retrograde intra-medullary nail results in a high rate of healing, a high rate of patient satisfaction, and relatively few complications.
Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.
Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer
2013-03-01
To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.
Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning
2013-03-01
Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Patterns of clinical nail appearances in patients with cutaneous psoriasis
MARINA, ELENA MIHAELA; BOTAR-JID, CAROLINA; BOLBOACA, SORANA DANIELA; ROMAN, IULIA IOANA; SENILA, CORINA SIMONA; MIHU, CARMEN MIHAELA; TATARU, DUMITRU ALEXANDRU
2017-01-01
Background and aim Nail manifestations are often an overlooked aspect in psoriatic disease, cutaneous and joint involvement being far more often reported and investigated. The reported prevalence of nail changes varies in literature, specific fingernail clinical features having different degrees of occurrence. The aim of this study was to describe specific clinical patterns of fingernail alterations in adult patients with plaque-type psoriasis in a university hospital in the North-West of Romania. Methods Clinical data of 35 patients with fingernail psoriasis were collected and analyzed. Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores were used to quantify disease extension in each patient. Results PASI score proved linearly correlated with NAPSI score (p<0.05). The age of onset of fingernail psoriasis was positively correlated with age of onset cutaneous psoriasis (p<0.0001). Furthermore, the duration of cutaneous involvement and NAPSI proved significantly related (p<0.05). The third fingernail in the right hand and first fingernail in the left hand were in most of the cases severely affected. The most common observed nail pattern was pitting, followed by salmon patches and subungual hyperkeratosis. Conclusion Important nail changes appear even in moderate forms of cutaneous psoriasis. Particular localization of specific fingernail psoriasis pattern enables the possibility of detecting early stage disease. PMID:28246493
Sensitivity and specificity of the online version of ImPACT in high school and collegiate athletes.
Schatz, Philip; Sandel, Natalie
2013-02-01
The utility of postconcussion neurocognitive testing versus symptom data has been debated. The sensitivity of the desktop version of the Immediate Post-concussion assessment and cognitive testing (ImPACT) tool has been documented, but psychometric properties of the recently released online version of ImPACT have yet to be fully established. To document the sensitivity of the online ImPACT version in samples of (1) symptomatic concussed (high school and collegiate) athletes, and (2) asymptomatic concussed (high school and collegiate) athletes suspected of hiding their concussions. Cohort study; level of evidence, 3. A total of 81 athletes observed to sustain a concussion by a certified athletic trainer or team physician, a finding that was confirmed with reported postconcussion symptoms, completed the ImPACT test within 3 days of injury. Data were compared with an independent sample of 81 athletes who completed preseason baseline cognitive assessments using ImPACT and who were matched (with concussed athletes) on the basis of sex, age, sport, concussion history, and absence of attention deficit hyperactivity disorder and learning disability. An independent group of 37 athletes who were also observed to sustain a concussion completed ImPACT within 3 days of injury. These athletes reported no postconcussion symptoms but were noted for suspected invalid response patterns on ImPACT (impulse control index >30 and verbal memory index <69%). The subscale data from the assessments (excluding those contributing to the aforementioned indices) were compared with a matched sample of 37 athletes who completed preseason baseline cognitive assessments in ImPACT (using the same criteria described above). Data from the ImPACT online version yielded 91.4% sensitivity and 69.1% specificity. For asymptomatic athletes suspected of hiding their concussion, data from ImPACT yielded 94.6% sensitivity and 97.3% specificity. The online version of the ImPACT tool is a valid measure of neurocognitive performance at the acute stages of concussion, with high levels of sensitivity and specificity, even when athletes appear to be denying postconcussion symptoms.
Wong, Carlos; Jiang, Minghuan; You, Joyce H S
2016-01-01
The influenza vaccine coverage rate of children is low in Hong Kong. Microneedle patches (MNPs) is a technology under development for painless delivery of vaccines. This study aimed to examine the potential clinical outcomes and direct medical costs of an influenza program offering MNP vaccine to children who have declined intramuscular (IM) vaccine in Hong Kong. A decision model was designed to compare potential outcomes between IM vaccine program and a program offering MNP vaccine to those declined IM vaccine (IM/MNP program) in a hypothetical cohort of children over one-year time horizon. The model outcomes included direct medical cost, influenza infection rate, mortality rate, and quality-adjusted life-years (QALYs) loss. Model inputs were retrieved from published literature. Sensitivity analyses were performed to examine the robustness of model results. In base-case analysis, IM/MNP program was more costly per child (USD19.13 versus USD13.69; USD1 = HKD7.8) with lower influenza infection rate (98.9 versus 124.8 per 1,000 children), hospitalization rate (0.83 versus 1.05 per 1,000 children) and influenza-related mortality rate (0.00042 versus 0.00052 per 1,000 children) when compared to IM program. The incremental cost per QALY saved (ICER) of IM/MNP program versus IM program was 27,200 USD/QALY. Using gross domestic product (GDP) per capita of Hong Kong (USD40,594) as threshold of willingness-to-pay (WTP) per QALY, one-way sensitivity analysis found ICER of IM/MNP to exceed WTP when duration of illness in outpatient setting was <5.7 days or cost per MNP vaccine was >1.39-time of IM vaccine cost. In 10,000 Monte Carlo simulations, IM/MNP program was the preferred option in 57.28% and 91.68% of the time, using 1x and 3x GDP per capita as WTP threshold, respectively. Acceptance of IM/MNP program as the preferred program was subject to the WTP threshold, duration of illness in outpatient settings, and cost of MNP vaccine.
Klos, Kajetan; Gueorguiev, Boyko; Schwieger, Karsten; Fröber, Rosemarie; Brodt, Steffen; Hofmann, Gunther O; Windolf, Markus; Mückley, Thomas
2009-12-01
Retrograde intramedullary nailing is an established technique for tibiotalocalcaneal arthrodesis (TTCA). In poor bone stock (osteoporosis, neuroarthropathy), device fixation in the hindfoot remains a problem. Fixed-angle spiral-blade fixation of the nail in the calcaneus could be useful. In seven matched pairs of human below-knee specimens, bone mineral density (BMD) was determined, and TTCA was performed with an intramedullary nail (Synthes Hindfoot Arthrodesis Nail HAN Expert Nailing System), using a conventional screw plus a fixed-angle spiral blade versus a conventional screw plus a fixed-angle screw, in the calcaneus. The constructs were subjected to quasi-static loading (dorsiflexion/plantarflexion, varus/valgus, rotation) and to cyclic loading to failure. Parameters studied were construct neutral zone (NZ) and range of motion (ROM), and number of cycles to failure. With dorsiflexion/plantarflexion loading, the screw-plus-spiral-blade constructs had a significantly smaller ROM in the quasi-static test (p = 0.028) and early in the cyclic test (p = 0.02); differences in the other parameters were not significant. There was a significant correlation between BMD and cycles to failure for the two-screw constructs (r = 0.94; p = 0.002) and for the screw-plus-spiral-blade constructs (r = 0.86; p = 0.014). In TTCA with a HAN Expert Nailing System, the use of a calcaneal spiral blade can further reduce motion within the construct. This may be especially useful in poor bone stock. Results obtained in this study could be used to guide the operating surgeon's TTCA strategy.
Kuwayama, Kenji; Miyaguchi, Hajime; Iwata, Yuko T; Kanamori, Tatsuyuki; Tsujikawa, Kenji; Yamamuro, Tadashi; Segawa, Hiroki; Inoue, Hiroyuki
2017-04-01
Hair and nails are often used to prove long-term intake of drugs in forensic drug testing. The aim of this study was to evaluate the effectiveness of drug testing using hair and nails and the feasibility of determining when drugs were ingested by measuring the time-courses of drug concentrations in hair and toenails after single administrations of various drugs. Healthy subjects ingested four pharmaceutical products containing eight active ingredients in single doses. Hair and toenails were collected at predetermined intervals, and drug concentrations in hair and nails were measured for 12 months. The administered drugs and their main metabolites were extracted using micropulverized extraction with a stainless steel bullet and were analyzed using liquid chromatography/tandem mass spectrometry. Acidic compounds such as ibuprofen and its metabolites were not detected in both specimens. Acetaminophen, a weakly acidic compound, was detected in nails more frequently than in hair. The maximum concentration of allyl isopropyl acetylurea, a neutral compound, in nails was significantly higher than in hair. Nails are an effective specimen to detect neutral and weakly acidic compounds. For fexofenadine, a zwitterionic compound, and for most basic compounds, the maximum concentrations in hair segments tended to be higher than those in nails. The hair segments showing the maximum concentrations varied between drugs, samples, and subjects. Drug concentrations in hair segments greatly depended on the selection of the hair. Careful interpretation of analytical results is required to predict the time of drug intake. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
A preliminary survey of Vietnamese nail salon workers in Alameda County, California.
Quach, Thu; Nguyen, Kim-Dung; Doan-Billings, Phuong-An; Okahara, Linda; Fan, Cathyn; Reynolds, Peggy
2008-10-01
In recent decades, the nail salon industry has been one of the fastest growing in the U.S. California has over 300,000 workers licensed to perform nail care services. Though little is known about their health, these workers routinely handle cosmetic products containing carcinogens and endocrine disruptors that may increase a woman's breast cancer risk. Additionally, an estimated 59-80% of California nail salons are run by Vietnamese women who face socio-cultural barriers that may compromise their workplace safety and health care access. In a pilot project designed to characterize Vietnamese nail salon workers in Alameda County, California in order to inform future health interventions and reduce occupational exposures, we conducted face-to-face surveys with a convenience sample of 201 Vietnamese nail salon workers at 74 salons. Of the workers surveyed, a majority reported that they are concerned about their health from exposure to workplace chemicals. Additionally, a sizeable proportion reported having experienced some health problem after they began working in the industry, particularly acute health problems that may be associated with solvent exposure (e.g. skin and eye irritation, breathing difficulties and headaches). Our findings highlight a critical need for further investigation into the breast cancer risk of nail salon workers, underscored by the workers' routine use of carcinogenic and endocrine-disrupting chemicals, their prevalent health concerns about such chemicals, and their high level of acute health problems. Moreover, the predominance of Vietnamese immigrant women in this workforce makes it an important target group for further research and health interventions.
Takahashi, María Denise; Chouela, Edgardo Néstor; Dorantes, Gladys Leon; Roselino, Ana Maria; Santamaria, Jesùs; Allevato, Miguel Angel; Cestari, Tania; de Aillaud, Maria Eugenia Manzanera; Stengel, Fernando Miguel; Licu, Daiana
2010-01-01
Introduction Plaque-type psoriasis affecting the nails, scalp, hands or feet can often be difficult to treat; for example, topical treatments and phototherapy may not penetrate the nail plate or scalp. The objective of this large, international, multicentre study was to investigate the efficacy of efalizumab in a Latin American population of adult patients with moderate-to-severe chronic plaque psoriasis who were candidates for systemic therapy or phototherapy. Methods Eligible patients were enrolled in a 24-week, open-label, single-arm, Phase IIIb/IV study of continuous treatment with subcutaneous efalizumab, 1.0 mg/kg/wk. Involvement of the nails, scalp, or hands or feet was assessed using the Nail Psoriasis Severity Index (NAPSI), the Psoriasis Scalp Severity Index (PSSI), or the Palmoplantar Pustulosis Psoriasis Area and Severity Index (PPPASI), respectively. Missing data were handled using a last observation carried forward or nonresponder imputation approach. Results Of the 189 patients who received treatment, 112 patients had nail involvement, 172 had scalp involvement, and 19 had palmoplantar disease at baseline. At Week 24, ≥50% improvement on the NAPSI, PSSI and PPPASI was observed in 31%, 71% and 68% of patients, respectively, whereas ≥75% improvement on these scores was observed in 17%, 52% and 63%, respectively. Descriptive statistics showed lower NAPSI-75 and higher PSSI-75 and -50 response rates among patients with higher baseline scores. Conclusions This open-label, uncontrolled study provides supportive evidence of the potential of efalizumab as a treatment for nail, scalp and palmoplantar psoriasis. PMID:20428227
The pharmacokinetics of intraosseous atropine in hypovolemic swine.
Yost, Jonathan; Baldwin, Phillip; Bellenger, Sarah; Bradshaw, Freida; Causapin, Edna; Demotica, Richelle; Livingston, Michael; Lee, Cynthia; Gegel, Brian; Burgert, James; Claessens, Adam; Johnson, Don; Loughren, Michael
2015-01-01
Compare the pharmacokinetics of atropine administered via the intravenous (IV), intramuscular (IM), and intraosseous (IO) routes in a normovolemic and hypovolemic swine model. Prospective, between subjects, experimental study. Vivarium. Yorkshire-cross swine (N = 36). Atropine was administered via IV, IM, or IO routes to normovolemic and hypovolemic swine. Blood samples were drawn at regular intervals after atropine administration and analyzed for plasma atropine concentration. Pharmacokinetic parameters were obtained from modeling the plasma concentrations. Pharmacokinetic parameters, maximum concentration (Cmax) and time to maximum concentration (Tmax). The IV and IO groups in both the normovolemic and hypovolemic models reached peak plasma concentration immediately and had a very rapid distribution phase with no apparent absorption phase for the IO groups. Peak plasma concentration and time to reach peak concentration were both significantly lower for the IM groups. There was a significant increase in absorption time with IM administration in the hypovolemic model compared to the normovolemic model. The IO route is an effective method of administering atropine and is comparable to the IV route even under conditions of significant hemorrhage. Therapeutic levels of atropine may be delayed and possibly difficult to obtain via IM injection in the presence of hypovolemic shock.
Yang, Jun; Hall, Keri; Nuriddin, Azizeh; Woolard, Diane
2014-01-01
The potential for hepatitis B and C virus (HBV/HCV) transmission in nail salons and barbershops has been reported, but a systematic review has not been conducted. These businesses are regulated by state cosmetology or barbering boards, but adequacy of sanitary requirements has not been evaluated. To conduct literature review to assess risk for HBV/HCV transmission in nail salons and barbershops and to evaluate sanitary requirements in HBV/HCV prevention in these businesses in 50 states and District of Columbia. Several search engines were used for literature search. Studies that quantified risks associated with manicuring, pedicuring, or barbering were included. State requirements for disinfection and sterilization were reviewed and evaluated. For literature review, odds ratios, 95% confidence intervals, and confounding adjustment were extracted and evaluated. For regulation review, requirements for disinfection or sterilization for multiuse items in nail salons and barbershops were assessed according to the US federal guidelines. Forty-six studies were identified and 36 were included in this study. Overall, the results were not consistent on risk for HBV/HCV transmission in nail salons and barbershops. For sanitary requirements, disinfection with an Environmental Protection Agency-registered disinfectant is required in 39 states for nail salons and in 26 states for barbershops. Sterilization was described in 15 states for nail salons and in 11 states for barbershops, but the majority of these states listed it as an optional approach. Sanitary requirements are consistent in states where 1 board regulates both businesses but are substantially discrepant in states with separate boards. Current literature cannot confirm or exclude the risk for HBV/HCV transmission in nail salons and barbershops. Existing sanitary requirements are adequate in the majority of states, but compliance is needed to prevent HBV/HCV transmission in these businesses.
Shi, Jian; Li, Jin; Huang, He; Permatasari, Felicia; Liu, Juan; Xu, Yang; Wu, Di; Zhou, Bing-Rong; Luo, Dan
2017-10-01
Although systemic and topical antifungal agents are widely used to treat onychomycosis, oral medications can cause adverse effects and the efficacy of topical agents is not satisfying. Currently, laser treatment has been studied for its efficacy in the treatment of onychomycosis. Our study was aimed to evaluate the efficacy of fractional carbon dioxide (CO 2 ) laser treatment combined with terbinafine cream for 6 months in the treatment of onychomycosis and to analyze the influencing factors. A total of 30 participants (124 nails) with clinical and mycological diagnosis of onychomycosis received fractional CO 2 laser treatment at 2-week interval combined with terbinafine cream once daily for 6 months. The clinical efficacy rate (CER) was assessed from the percentage of fully normal-appearing nails or nails with ≤5% abnormal appearance, and the mycological clearance rate (MCR) was assessed from the percentage of nails with negative fungal microscopy. The CER was evaluated at 3 time points: at the end of treatment (58.9%), at 1 month after the last treatment (63.5%), and at 3 months after the last treatment (68.5%). The MCRs at 1 month and 3 months after the last treatment were 77.4 and 74.2%, respectively. The evaluation of influencing factors showed significantly higher CER (p < 0.05) in nails of participants with age <50 years, distal lateral subungual onychomycosis (DLSO), superficial white onychomycosis (SWO), nail thickness <2 mm, affected first-to-fourth finger/toenails, Trichophyton rubrum, and Trichophyton mentagrophytes. All participants experienced tolerable mild burning sensation during laser treatment, but there were no other adverse reactions reported. Fractional CO 2 laser treatment combined with terbinafine cream for 6 months was an effective and safe method for the treatment of onychomycosis. There were 5 factors that positively influenced the treatment outcome: age, clinical type of onychomycosis, nail thickness, involved nail, and species of fungus.
White, T O; Bugler, K E; Appleton, P; Will, E; McQueen, M M; Court-Brown, C M
2016-09-01
The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems. A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months. Significantly fewer wound infections occurred in the fibular nail group (p = 0.002). At one year, there was no evidence of difference in mean functional scores (Olerud and Molander Scores 63; 30 to 85, versus 61; 10 to 35, p = 0.61) or scar satisfaction. The overall cost of treatment in the fibular nail group was £91 less than in the ORIF group despite the higher initial cost of the implant. We conclude that the fibular nail allows accurate reduction and secure fixation of ankle fractures, with a significantly lower rate of soft-tissue complications, and is more cost-effective than ORIF. Cite this article: Bone Joint J 2016;98-B:1248-52. ©2016 The British Editorial Society of Bone & Joint Surgery.
Razii, Nima; Abbas, Ammar M I; Kakar, Rahul; Agarwal, Sanjeev; Morgan-Jones, Rhidian
2016-12-01
Periprosthetic infection following total knee arthroplasty is a devastating complication, which is not always satisfactorily resolved by revision surgery. Arthrodesis is a salvage alternative to above-knee amputation or permanent resection arthroplasty. Fixation options include internal compression plating, external fixation, and intramedullary nails. We retrospectively reviewed twelve consecutive cases (9 males, 3 females; mean age, 67 years) of knee arthrodesis with a long intramedullary nail, performed at a single institution between 2003 and 2014. Desired outcomes were the ability to mobilize without pain, solid radiographic fusion, and the eradication of infection. Mean follow-up was 48.5 months (range, 9-120 months). Eleven patients (92 %) demonstrated stable fusion, ten patients (83 %) were ambulatory without pain, and ten patients (83 %) remained without infection at most recent follow-up. Eight patients (67 %) achieved union at an average of 12 months; three required repeat procedures, achieving union at an average of 9 months. There was a significant difference (P < 0.01) between the numbers of previous operations amongst the eight patients who initially achieved union (mean, 3.25) and three who subsequently required repeat procedures (mean, 8.33). In contrast to similar studies, we performed a single-stage exchange where possible, while comparable ambulatory and fusion rates were observed. Numerous previous attempts at revision arthroplasty, co-morbidities, and infections with highly resistant organisms have been associated with further complications. Although technically challenging, knee arthrodesis with a long intramedullary nail offers an acceptable limb salvage procedure for carefully selected patients with complex periprosthetic infections.
[Hindfoot fusion for Charcot osteoarthropathy with a curved retrograde nail].
Pyrc, J; Fuchs, A; Zwipp, H; Rammelt, S
2015-01-01
Charcot osteoarthropathy of the hindfoot with considerable dislocation and instability represents a therapeutic dilemma. The treatment goal is a plantigrade, stable foot that is free of infection and ulceration with the ability to ambulate in special footwear. Over a period of 6 years, we performed 23 hindfoot fusions in 21 patients with manifest Charcot arthropathy with the help of a curved retrograde nail (HAN). All patients suffered from insulin-dependent diabetes mellitus with polyneuropathy; 12 patients had additional peripheral vasculopathy. An average of 3.5 previous surgeries had been performed prior to hindfoot fusion. Complete tibiotalocalcaneal fusion was obtained in 16 of 21 patients (76 %). Of these 21 patients, 18 (86 %) were followed clinically and radiologically for an average of 2 years. Overall, 16 patients (89 %) reported a substantial subjective improvement compared to the preoperative state. Hardware failure occurred in 7 cases (30 %) that could be brought to consolidation with exchange of the locking bolts or the complete nail. In 5 cases (22 %), a postoperative hematoma had to be removed and in 8 cases (35 %) wound edge necrosis was treated with local wound care. In 2 cases (9 %), a secondary or reactivated osteitis occurred that finally required below knee amputation. Tibiotalocalcaneal fusion with a curved retrograde intramedullary nail (HAN) is an effective treatment option in highly unstable and deforming Charcot osteoarthropathy of the hindfoot. It is an alternative to external or other internal fixation methods and helps to avoid below knee amputation in more than 90 % of cases.