Sample records for comparing objective measures

  1. Validity of Questionnaire and Representativeness of Objective Methods for Measurements of Mechanical Exposures in Construction and Health Care Work.

    PubMed

    Koch, Markus; Lunde, Lars-Kristian; Gjulem, Tonje; Knardahl, Stein; Veiersted, Kaj Bo

    2016-01-01

    To determine the criterion validity of a questionnaire on physical exposures compared to objective measurements at construction and health care sites and to examine exposure variation over several working days. Five hundred ninety-four construction and health care workers answered a baseline questionnaire. The daily activities (standing, moving, sitting, number of steps), postures (inclination of the arm and the trunk), and relative heart rate of 125 participants were recorded continuously over 3-4 working days. At the end of the first measurement day, the participants answered a second questionnaire (workday questionnaire). All objective activity measurements had significant correlations to their respective questions. Among health care workers, there were no correlations between postures and relative heart rate and the baseline questionnaire. The questionnaires overestimated the exposure durations. The highest explained variance in the adjusted models with self-reported variables were found for objectively measured sitting (R2 = 0.559) and arm inclination > 60° (R2 = 0.420). Objective measurements over several days showed a higher reliability compared to single day measurements. Questionnaires cannot provide an accurate description of mechanical exposures. Objective measurements over several days are recommended in occupations with varying tasks.

  2. Validity of Questionnaire and Representativeness of Objective Methods for Measurements of Mechanical Exposures in Construction and Health Care Work

    PubMed Central

    Koch, Markus; Lunde, Lars-Kristian; Gjulem, Tonje; Knardahl, Stein; Veiersted, Kaj Bo

    2016-01-01

    Objectives To determine the criterion validity of a questionnaire on physical exposures compared to objective measurements at construction and health care sites and to examine exposure variation over several working days. Methods Five hundred ninety-four construction and health care workers answered a baseline questionnaire. The daily activities (standing, moving, sitting, number of steps), postures (inclination of the arm and the trunk), and relative heart rate of 125 participants were recorded continuously over 3–4 working days. At the end of the first measurement day, the participants answered a second questionnaire (workday questionnaire). Results All objective activity measurements had significant correlations to their respective questions. Among health care workers, there were no correlations between postures and relative heart rate and the baseline questionnaire. The questionnaires overestimated the exposure durations. The highest explained variance in the adjusted models with self-reported variables were found for objectively measured sitting (R2 = 0.559) and arm inclination > 60° (R2 = 0.420). Objective measurements over several days showed a higher reliability compared to single day measurements. Conclusions Questionnaires cannot provide an accurate description of mechanical exposures. Objective measurements over several days are recommended in occupations with varying tasks. PMID:27649499

  3. Objective measurements to evaluate glottal space segmentation from laryngeal images.

    PubMed

    Gutiérrez-Arriola, J M; Osma-Ruiz, V; Sáenz-Lechón, N; Godino-Llorente, J I; Fraile, R; Arias-Londoño, J D

    2012-01-01

    Objective evaluation of the results of medical image segmentation is a known problem. Applied to the task of automatically detecting the glottal area from laryngeal images, this paper proposes a new objective measurement to evaluate the quality of a segmentation algorithm by comparing with the results given by a human expert. The new figure of merit is called Area Index, and its effectiveness is compared with one of the most used figures of merit found in the literature: the Pratt Index. Results over 110 laryngeal images presented high correlations between both indexes, demonstrating that the proposed measure is comparable to the Pratt Index and it is a good indicator of the segmentation quality.

  4. Does Occupational Mobility Influence Health among Working Women? Comparing Objective and Subjective Measures of Work Trajectories

    ERIC Educational Resources Information Center

    Wilkinson, Lindsay R.; Shippee, Tetyana P.; Ferraro, Kenneth F.

    2012-01-01

    Occupational mobility is highly valued in American society, but is it consequential to women's health? Previous studies have yielded inconsistent results, but most measured occupational mobility by identifying transitions across occupational categories. Drawing from cumulative inequality theory, this study (1) compares objective and subjective…

  5. A comparison of subjective and objective measures of physical activity from the Newcastle 85+ study.

    PubMed

    Innerd, Paul; Catt, Michael; Collerton, Joanna; Davies, Karen; Trenell, Michael; Kirkwood, Thomas B L; Jagger, Carol

    2015-07-01

    Little is known about physical activity (PA) in the very old, the fastest growing age group in the population. We aimed to examine the convergent validity of subjective and objective measures of PA in adults aged over 85 years. A total of 484 participants aged 87-89 years recruited to the Newcastle 85+ study completed a purpose-designed physical activity questionnaire (PAQ), which categorised participants as mildly active, moderately active and very active. Out of them, 337 participants wore a triaxial, raw accelerometer on the right wrist over a 5-7-day period to obtain objective measures of rest/activity, PA intensity and PA type. Data from subjective and objective measurement methods were compared. Self-reported PA was significantly associated with objective measures of the daily sedentary time, low-intensity PA and activity type classified as sedentary, activities of daily living and walking. Objective measures of PA were significantly different when low, moderate and high self-reported PA categories were compared (all P < 0.001). The Newcastle 85+ PAQ demonstrated convergent validity with objective measures of PA. Our findings suggest that this PAQ can be used in the very old to rank individuals according to their level of total PA. © The Author 2015. Published by Oxford University Press on behalf of the British Geriatrics Society.

  6. Comparison of self-report and objective measures of driving behavior and road safety: A systematic review.

    PubMed

    Kaye, Sherrie-Anne; Lewis, Ioni; Freeman, James

    2018-06-01

    This research systematically reviewed the existing literature in regards to studies which have used both self-report and objective measures of driving behavior. The objective of the current review was to evaluate disparities or similarities between self-report and objective measures of driving behavior. Searches were undertaken in the following electronic databases, PsycINFO, PubMed, and Scopus, for peer-reviewed full-text articles that (1) focused on road safety, and (2) compared both subjective and objective measures of driving performance or driver safety. A total of 22,728 articles were identified, with 19 articles, comprising 20 studies, included as part of the review. The research reported herein suggested that for some behaviors (e.g., driving in stressful situations) there were similarities between self-report and objective measures while for other behaviors (e.g., sleepiness and vigilance states) there were differences between these measurement techniques. In addition, findings from some studies suggested that in-vehicle devices may be a valid measurement tool to assess driving exposure in older drivers. Further research is needed to examine the correspondence between self-report and objective measures of driving behavior. In particular, there is a need to increase the number of studies which compare "like with like" as it is difficult to draw comparisons when there are variations in measurement tools used. Incorporating a range of objective and self-report measurements tools in research would help to ensure that the methods used offer the most reliable measures of assessing on-road behaviors. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  7. Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study.

    PubMed

    Braian, Michael; Jönsson, David; Kevci, Mir; Wennerberg, Ann

    2018-07-01

    To evaluate the accuracy and precision of objects produced by additive manufacturing systems (AM) for use in dentistry and to compare with subtractive manufacturing systems (SM). Ten specimens of two geometrical objects were produced by five different AM machines and one SM machine. Object A mimics an inlay-shaped object, while object B imitates a four-unit bridge model. All the objects were sorted into different measurement dimensions (x, y, z), linear distances, angles and corner radius. None of the additive manufacturing or subtractive manufacturing groups presented a perfect match to the CAD file with regard to all parameters included in the present study. Considering linear measurements, the precision for subtractive manufacturing group was consistent in all axes for object A, presenting results of <0.050mm. The additive manufacturing groups had consistent precision in the x-axis and y-axis but not in the z-axis. With regard to corner radius measurements, the SM group had the best overall accuracy and precision for both objects A and B when compared to the AM groups. Within the limitations of this in vitro study, the conclusion can be made that subtractive manufacturing presented overall precision on all measurements below 0.050mm. The AM machines also presented fairly good precision, <0.150mm, on all axes except for the z-axis. Knowledge regarding accuracy and precision for different production techniques utilized in dentistry is of great clinical importance. The dental community has moved from casting to milling and additive techniques are now being implemented. Thus all these production techniques need to be tested, compared and validated. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  8. Archimedes Revisited: A Faster, Better, Cheaper Method of Accurately Measuring the Volume of Small Objects

    ERIC Educational Resources Information Center

    Hughes, Stephen W.

    2005-01-01

    A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…

  9. Application of comparative digital holography for distant shape control

    NASA Astrophysics Data System (ADS)

    Baumbach, Torsten; Osten, Wolfgang; von Kopylow, Christoph; Juptner, Werner P. O.

    2004-09-01

    The comparison of two objects is of great importance in the industrial production process. Especially comparing the shape is of particular interest for maintaining calibration tools or controlling the tolerance in the deviation between a sample and a master. Outsourcing and globalization of production places can result in large distances between co-operating partners and might cause problems for maintaining quality standards. Consequently new challenges arise for optical measurement techniques especially in the field of industrial shape control. In this paper we describe the progress of implementing a novel technique for comparing directly two objects with different microstructure. The technique is based on the combination of comparative holography and digital holography. Comparing the objects can be done in two ways. One is the digital comparison in the computer and the other way is by using the analogue reconstruction of a master hologram with a spatial light modulator (SLM) as coherent mask for illuminating the test object. Since this mask is stored digitally it can be transmitted via telecommunication networks and this enables the access to the full optical information of the master object at any place wanted. Beside the basic principle of comparative digital holography (CDH), we will show in this paper the set-up for doing the analogue comparison of two objects with increased sensitivity in comparison to former measurements and the calibration of the SLM that is used for the experiments. We will give examples for the digital and the analogue comparison of objects including a verification of our results by another optical measurement technique.

  10. Examination of Skill Acquisition and Grader Bias in a Distal Radius Fracture Fixation Model.

    PubMed

    Putnam, Matthew D; Adams, Julie E; Lender, Paul; Van Heest, Ann E; Shanedling, Janet R; Nuckley, David J; Bechtold, Joan E

    2018-03-01

    Primary: Assess the ability of faculty graders to predict the objectively measured strength of distal radius fracture fixation. Secondary: Compare resident skill variation and retention related to other knowable training data. Residents were allowed 60 minutes to stabilize a standardized distal radius fracture using an assigned fixed-angle volar plate. Faculty observed and subjectively graded the residents without providing real-time feedback. Objective biomechanical evaluation (construct strength and stiffness) was compared to subjective grades. Resident-specific characteristics (sex, PGY, and ACGME case log) were also used to compare the objective data. A simulated operating room in our laboratory. Post-graduate year 2, 3, 4, and 5 orthopedic residents. Primary: Faculty were not successful at predicting objectively measured fixation, and their subjective scoring suggests confirmation bias as PGY increased. Secondary: Resident year-in-training alone did not predict objective measures (p = 0.53), but was predictive of subjective scores (p < 0.001). Skills learned were not always retained, as 29% of residents objectively failed subsequent to passing. Notably, resident-reported case-specific experience alone was inversely correlated with objective fixation strength. This testing model enabled the collection of objective and subjective resident skill scores. Faculty graders did not routinely predict objective measures, and their subjective assessment appears biased related to PGY. Also, in vivo case volume alone does not predict objective results. Familiar faculty teaching consistency, and resident grading by external faculty unfamiliar with tested residents, might alter these results. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Developing a New Similarity Measure from Two Different Perspectives.

    ERIC Educational Resources Information Center

    Zhang, Jin; Rasmussen, Edie M.

    2001-01-01

    Compares two similarity measures for information retrieval in a document vector space, the distance-based and the angle-based, and presents a newly developed similarity measure based on both the distance and angle strengths of two compared objects. Introduces the concept of the iso-extent contour and then compares all three similarity measures.…

  12. Assessment of antitussive efficacy of dextromethorphan in smoking related cough: objective vs. subjective measures

    PubMed Central

    Ramsay, James; Wright, Caroline; Thompson, Rachel; Hull, David; Morice, Alyn H

    2008-01-01

    AIMS Using an established model of smokers cough we measured the antitussive effects of dextromethorphan compared with placebo. METHODS The study was a randomized, double-blind placebo controlled, crossover comparison of 22 mg 0.8 ml−1 dextromethorphan delivered pregastrically with matched placebo. Objective and subjective measurements of cough were recorded. Subjective measures included a daily diary record of cough symptoms and the Leicester quality of life questionnaire. Cough frequency was recorded using a manual cough counter. The objective measure of cough reflex sensitivity was the citric acid, dose–response cough challenge. RESULTS Dextromethorphan was significantly associated with an increase in the concentration of citric acid eliciting an average of two coughs/inhalation (C2) when compared with placebo, 1 h post dose by 0.49 mM (95% CI 0.05, 0.45, geometric mean 3.09) compared with placebo 0.24 mM (geometric mean 1.74) P < 0.05 and at 2 h 0.57 mM (95% CI 0.01, 0.43, geometric mean 3.75) compared with placebo 0.34 mM (geometric mean 2.19) P < 0.05). There was a highly significant improvement in the subjective data when compared with baseline. However, there was no significant difference between placebo and active treatment. No correlation was seen between cough sensitivity to citric acid and recorded cough counts or symptoms. When both subjective and objective data were compared with screening data there was evidence of a marked ‘placebo’ effect. CONCLUSIONS The objective measure of cough sensitivity demonstrates dextromethorphan effectively diminishes the cough reflex sensitivity. However, subjective measures do not support this. Other studies support these findings, which may represent a profound sensitivity of the cough reflex to higher influences. WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT Dextromethorphan is widely used as a cough suppressant in over the counter medications. Its efficacy in altering cough reflex sensitivity has been shown in healthy volunteers. In contrast evidence for an effect on clinically important cough is poor. WHAT THIS STUDY ADDS A significant decrease in evoked cough was seen with dextromethorphan compared with placebo. However, both placebo and active treatment improved subjective data to a similar degree. We doubt the validity of currently used objective tests in the investigation of antitussives. PMID:18279476

  13. Self-perceived versus objectively measured competence in performing clinical practical procedures by final year medical students

    PubMed Central

    Banda, Sekelani

    2016-01-01

    Objectives To determine and compare the self-perceived and objectively measured competence in performing 14 core-clinical practical procedures by Final Year Medical Students of the University of Zambia. Methods The study included 56 out of 60 graduating University of Zambia Medical Students of the 2012/2013 academic year. Self-perceived competence: students rated their competence on 14 core- clinical practical procedures using a self-administered questionnaire on a 5-point Likert scale. Objective competence: it was measured by Objective Structured Clinical Examination (OSCE) by faculty using predetermined rating scales. Rank order correlation test was performed for self-perceived and objectively measured competence. Results Two thirds 36 (66.7%) of the participants perceived themselves as moderately competent, 15 (27.8%) rated themselves as highly competent while 3 (5.6%) had low self-perception. With objective competence, the majority 52 (92.8%) were barely competent while 4 (7.2%) were absolutely competent. When overall self-perception was compared to objectively measured competence, there was a discordance which was demonstrated by a negative correlation (Spearman rho -.123). Conclusions Significant numbers of students reported low self-competence in performing procedures such as endotracheal intubation, gastric lavage and cardiopulmonary resuscitation which most never performed during the clinical years of medical education. In addition, the negative correlation between self-perceived and objectively measured competence demonstrated the inability of students to assess and rate themselves objectively due to fear that others may know their weaknesses and realize that they are not as competent as expected at a specific level of training. PMID:27132255

  14. Electronic heterodyne moire deflectometry: A method for transient and three dimensional density fields measurements

    NASA Technical Reports Server (NTRS)

    Stricker, Josef

    1987-01-01

    Effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are investigated. The deferred deflectometry is used for measurements of nonsteady phase objects where it is difficult to complete the analysis of the field in real time. The sensitivity, accuracy and resolution of the system are calculated and it is shown that they are weakly affected by diffraction and by nonlinear recording. The feactures of the system are significantly improved compared with the conventional deferred intensity moire technique, and are comparable with the online heterodyne moire. The system was evaluated experimentally by deferred measurements of the refractive index gradients of a weak phase object consisting of a large KD*P crystal. This was done by photographing the phase object through a Ronchi grating and analyzing the tranparency with the electronic heterodyne readout system. The results are compared with the measurements performed on the same phase object with online heterodyne moire deflectometry and with heterodyne holographic interferometry methods. Some practical considerations for system improvement are discussed.

  15. Twin Study on Heritability of Activity, Attention, and Impulsivity as Assessed by Objective Measures

    ERIC Educational Resources Information Center

    Heiser, Philip; Heinzel-Gutenbrunner, Monika; Frey, Joachim; Smidt, Judith; Grabarkiewicz, Justyna; Friedel, Susann; Kuhnau, Wolfgang; Schmidtke, Jorg; Remschmidt, Helmut; Hebebrand, Johannes

    2006-01-01

    Objective: The purpose of this study was to assess heritability of activity, attention, and impulsivity by comparing young monozygotic (MZ) twins with dizygotic (DZ) twins using objective measures. Method: The OPTAx test is an infrared motion analysis to record the movement pattern during a continuous performance test. Seventeen MZ and 12 same…

  16. Ability of College Students to Simulate ADHD on Objective Measures of Attention

    ERIC Educational Resources Information Center

    Booksh, Randee Lee; Pella, Russell D.; Singh, Ashvind N.; Gouvier, William Drew

    2010-01-01

    Objective: The authors examined the ability of college students to simulate ADHD symptoms on objective and self-report measures and the relationship between knowledge of ADHD and ability to simulate ADHD. Method: Undergraduate students were assigned to a control or a simulated ADHD malingering condition and compared with a clinical AD/HD group.…

  17. Subjective Sleep Complaints in Pediatric Depression: A Controlled Study and Comparison with EEG Measures of Sleep and Waking

    ERIC Educational Resources Information Center

    Bertocci, Michele A.; Dahl, Ronald E.; Williamson, Douglas E.; Iosif, Ana-Maria; Birmaher, Boris; Axelson, David; Ryan, Neal D.

    2005-01-01

    Objective: Children with major depressive disorder (MDD) often complain of sleep disturbances; however, polysomnographic studies have failed to find objective evidence of these disturbances. This article examines subjective sleep reports of children with MDD and healthy controls focusing on comparing subjective and objective sleep measures.…

  18. "Chips with Everything": A Laboratory Exercise for Comparing Subjective and Objective Measurements of Potato Chips

    ERIC Educational Resources Information Center

    Davies, Cathy

    2005-01-01

    The following laboratory exercise was designed to aid student understanding of the differences between subjective and objective measurements. Students assess the color and texture of different varieties of potato chip (crisps) by means of an intensity rating scale and a rank test and objectively with a colorimeter and texture analyzer. For data…

  19. Self-perceived versus objectively measured competence in performing clinical practical procedures by final year medical students.

    PubMed

    Katowa-Mukwato, Patricia; Banda, Sekelani

    2016-04-30

    To determine and compare the self-perceived and objectively measured competence in performing 14 core-clinical practical procedures by Final Year Medical Students of the University of Zambia. The study included 56 out of 60 graduating University of Zambia Medical Students of the 2012/2013 academic year. Self-perceived competence: students rated their competence on 14 core- clinical practical procedures using a self-administered questionnaire on a 5-point Likert scale. Objective competence: it was measured by Objective Structured Clinical Examination (OSCE) by faculty using predetermined rating scales. Rank order correlation test was performed for self-perceived and objectively measured competence. Two thirds 36 (66.7%) of the participants perceived themselves as moderately competent, 15 (27.8%) rated themselves as highly competent while 3 (5.6%) had low self-perception. With objective competence, the majority 52 (92.8%) were barely competent while 4 (7.2%) were absolutely competent. When overall self-perception was compared to objectively measured competence, there was a discordance which was demonstrated by a negative correlation (Spearman rho -.123). Significant numbers of students reported low self-competence in performing procedures such as endotracheal intubation, gastric lavage and cardiopulmonary resuscitation which most never performed during the clinical years of medical education. In addition, the negative correlation between self-perceived and objectively measured competence demonstrated the inability of students to assess and rate themselves objectively due to fear that others may know their weaknesses and realize that they are not as competent as expected at a specific level of training.

  20. Measurement of Cognitive Load in Multimedia Learning: A Comparison of Different Objective Measures

    ERIC Educational Resources Information Center

    Korbach, Andreas; Brünken, Roland; Park, Babette

    2017-01-01

    Different indicators are interesting for analyzing human learning processes. Recent studies analyze learning performance in combination with cognitive load, as an indicator for learners' invested mental effort. In order to compare different measures of cognitive load research, the present study uses three different objective methods and one…

  1. Sleep Quality in Adolescents With Chronic Fatigue Syndrome/Myalgic Encephalomyelitis (CFS/ME).

    PubMed

    Josev, Elisha K; Jackson, Melinda L; Bei, Bei; Trinder, John; Harvey, Adrienne; Clarke, Cathriona; Snodgrass, Kelli; Scheinberg, Adam; Knight, Sarah J

    2017-09-15

    Little is known about the type and severity of sleep disturbances in the pediatric chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME) population, compared with healthy adolescents. Using a range of objective and subjective measures, the aim of this study was to investigate sleep quality, the relationship between objective and subjective measures of sleep quality, and their associations with anxiety in adolescents with CFS/ME compared with healthy controls. Twenty-one adolescents with CFS/ME aged 13 to 18 years (mean age 15.57 ± 1.40), and 145 healthy adolescents aged 13 to 18 years (mean age 16.2 ± 1.00) wore actigraphy watches continuously for 2 weeks to collect a number of objective sleep variables. The Pittsburgh Sleep Quality Index was used to obtain a subjective measure of sleep quality. Anxiety was measured by the Spence Children's Anxiety scale. On average over the 2-week period, adolescents with CFS/ME were found to have (1) significantly longer objective sleep onset latency, time in bed, total sleep time, and a later rise time (all P < .005), and (2) significantly poorer subjective sleep quality ( P < .001), compared with healthy adolescents. The CFS/ME patient group displayed higher levels of anxiety ( P < .05), and in both groups, higher levels of anxiety were significantly related to poorer subjective sleep quality ( P < .001). This study provides objective and subjective evidence of sleep disturbance in adolescents with CFS/ME compared with healthy adolescent controls. © 2017 American Academy of Sleep Medicine

  2. Comparison of an objective method of measuring bulbar redness to the use of traditional grading scales.

    PubMed

    Sorbara, Luigina; Simpson, Trefford; Duench, Stephanie; Schulze, Marc; Fonn, Desmond

    2007-03-01

    The primary objective was to compare measures of bulbar redness objectively using a photometric method with standard grading methods. Measures of redness were made on 24 participants wearing a silicone hydrogel contact lens in one eye for overnight wear. This report compares hyperaemia after 1 week of daily wear (baseline) with redness measured after 6 months of overnight wear. A new method of objectively measuring bulbar conjunctival redness was performed using the Spectrascan650 Photometer by Photo Research under fixed illumination. Photometric measures in CIEu(*) chromaticity values involve the measurement of chromaticity, a physical analogue of redness, greenness and blueness in the image. This method was validated in Part 1 of the study using repeated measurements on the photographic CCLRU scale. In Part 2 of the study, the photographic grading scale (CCLRU) from 0 (none) to 100 (extreme) was used to make the comparison. Part 1 indicated that the photometer provides a repeatable and reliable measure of bulbar redness (CCC=0.989). A moderately strong and significant correlation was found between the CIEu(*) chromaticity values and the analogue data (R=0.795, p=0.000) at each measurement session (from baseline to 1 day, 1 week, and 1, 3 and 6 months of overnight wear). This new standardized and objective method of measuring bulbar redness has great potential to replace subjective grading scales, especially with multi-centre studies, where variability between investigators occurs. This method may also detect smaller changes between visits or between eyes.

  3. Radiometer calibration procedure and beacon attenuation estimation reference level

    NASA Technical Reports Server (NTRS)

    Crane, Robert K.

    1994-01-01

    The primary objectives are to compare radiometer attenuation with beacon attenuation and to compare sky temperature estimates with calculations using simultaneous meteorological data. Secondary objectives are: (1) noise diode and reference load measurements and (2) to adjust for outside temperature and component temperature changes.

  4. A systematic review of objective burn scar measurements.

    PubMed

    Lee, Kwang Chear; Dretzke, Janine; Grover, Liam; Logan, Ann; Moiemen, Naiem

    2016-01-01

    Problematic scarring remains a challenging aspect to address in the treatment of burns and can significantly affect the quality of life of the burn survivor. At present, there are few treatments available in the clinic to control adverse scarring, but experimental pharmacological anti-scarring strategies are now beginning to emerge. Their comparative success must be based on objective measurements of scarring, yet currently the clinical assessment of scars is not carried out systematically and is mostly based on subjective review of patients. However, several techniques and devices are being introduced that allow objective analysis of the burn scar. The aim of this article is to evaluate various objective measurement tools currently available and recommend a useful panel that is suitable for use in clinical trials of anti-scarring therapies. A systematic literature search was done using the Web of Science, PubMed and Cochrane databases. The identified devices were then classified and grouped according to the parameters they measured. The tools were then compared and assessed in terms of inter- and intra-rater reproducibility, ease of use and cost. After duplicates were removed, 5062 articles were obtained in the search. After further screening, 157 articles which utilised objective burn scar measurement systems or tools were obtained. The scar measurement devices can be broadly classified into those measuring colour, metric variables, texture, biomechanical properties and pathophysiological disturbances. Objective scar measurement tools allow the accurate and reproducible evaluation of scars, which is important for both clinical and scientific use. However, studies to evaluate their relative performance and merits of these tools are scarce, and there remain factors, such as itch and pain, which cannot be measured objectively. On reviewing the available evidence, a panel of devices for objective scar measurement is recommended consisting of the 3D cameras (Eykona/Lifeviz/Vectra H1) for surface area and volume, DSM II colorimeter for colour, Dermascan high-frequency ultrasound for scar thickness and Cutometer for skin elasticity and pliability.

  5. Impact of smoking status on workplace absenteeism and productivity

    PubMed Central

    Halpern, M.; Shikiar, R.; Rentz, A.; Khan, Z.

    2001-01-01

    OBJECTIVES—To: evaluate the impact of smoking status on objective productivity and absenteeism measures; evaluate the impact of smoking status on subjective measures of productivity; and assess the correlation between subjective and objective productivity measures.
DESIGN—Prospective cohort study in a workplace environment.
SUBJECTS—Approximately 300 employees (100 each of former, current, and never smokers) at a reservation office of a large US airline.
MAIN OUTCOME MEASURES—Objective productivity and absenteeism data were supplied by the employer. Subjective assessments of productivity were collected using a self report instrument, the Health and Work Questionnaire (HWQ).
RESULTS—Current smokers had significantly greater absenteeism than did never smokers, with former smokers having intermediate values; among former smokers, absenteeism showed a significant decline with years following cessation. Former smokers showed an increase in seven of 10 objective productivity measures as compared to current smokers, with a mean increase of 4.5%. While objective productivity measures for former smokers decreased compared to measures for current smokers during the first year following cessation, values for former smokers were greater than those for current smokers by 1-4 years following cessation. Subjective assessments of "productivity evaluation by others" and "personal life satisfaction" showed significant trends with highest values for never smokers, lowest for current smokers, and intermediate for former smokers.
CONCLUSIONS—Workplace productivity is increased and absenteeism is decreased among former smokers as compared to current smokers. Productivity among former smokers increases over time toward values seen among never smokers. Subjective measures of productivity provide indications of novel ways of productivity assessment that are sensitive to smoking status.


Keywords: smoking cessation; workplace; absenteeism; productivity; questionnaires PMID:11544387

  6. Using Subjective and Objective Measures to Predict Level of Reading Fluency at the End of First Grade

    ERIC Educational Resources Information Center

    Morris, Darrell; Pennell, Ashley M.; Perney, Jan; Trathen, Woodrow

    2018-01-01

    This study compared reading rate to reading fluency (as measured by a rating scale). After listening to first graders read short passages, we assigned an overall fluency rating (low, average, or high) to each reading. We then used predictive discriminant analyses to determine which of five measures--accuracy, rate (objective); accuracy, phrasing,…

  7. Visual Sensitivities and Discriminations and Their Roles in Aviation.

    DTIC Science & Technology

    1986-03-01

    D. Low contrast letter charts in early diabetic retinopathy , octrlar hypertension, glaucoma and Parkinson’s disease. Br J Ophthalmol, 1984, 68, 885...to detect a camouflaged object that was visible only when moving, and compared these data with similar measurements for conventional objects that were...3) Compare visual detection (i.e. visual acquisition) of camouflaged objects whose edges are defined by velocity differences with visual detection

  8. Relationship between parental estimate and an objective measure of child television watching

    PubMed Central

    Robinson, Jodie L; Winiewicz, Dana D; Fuerch, Janene H; Roemmich, James N; Epstein, Leonard H

    2006-01-01

    Many young children have televisions in their bedrooms, which may influence the relationship between parental estimate and objective measures of child television usage/week. Parental estimates of child television time of eighty 4–7 year old children (6.0 ± 1.2 years) at the 75th BMI percentile or greater (90.8 ± 6.8 BMI percentile) were compared to an objective measure of television time obtained from TV Allowance™ devices attached to every television in the home over a three week period. Results showed that parents overestimate their child's television time compared to an objective measure when no television is present in the bedroom by 4 hours/week (25.4 ± 11.5 vs. 21.4 ± 9.1) in comparison to underestimating television time by over 3 hours/week (26.5 ± 17.2 vs. 29.8 ± 14.4) when the child has a television in their bedroom (p = 0.02). Children with a television in their bedroom spend more objectively measured hours in television time than children without a television in their bedroom (29.8 ± 14.2 versus 21.4 ± 9.1, p = 0.003). Research on child television watching should take into account television watching in bedrooms, since it may not be adequately assessed by parental estimates. PMID:17129381

  9. Comparison of 3D displays using objective metrics

    NASA Astrophysics Data System (ADS)

    Havig, Paul; McIntire, John; Dixon, Sharon; Moore, Jason; Reis, George

    2008-04-01

    Previously, we (Havig, Aleva, Reis, Moore, and McIntire, 2007) presented a taxonomy for the development of three-dimensional (3D) displays. We proposed three levels of metrics: objective (in which physical measurements are made of the display), subjective (Likert-type rating scales to show preferences of the display), and subjective-objective (performance metrics in which one shows how the 3D display may be more or less useful than a 2D display or a different 3D display). We concluded that for each level of metric, drawing practical comparisons among currently disparate 3D displays is difficult. In this paper we attempt to define more clearly the objective metrics for 3D displays. We set out to collect and measure physical attributes of several 3D displays and compare the results. We discuss our findings in terms of both difficulties in making the measurements in the first place, due to the physical set-up of the display, to issues in comparing the results we found and comparing how similar (or dissimilar) two 3D displays may or may not be. We conclude by discussing the next steps in creating objective metrics for three-dimensional displays as well as a proposed way ahead for the other two levels of metrics based on our findings.

  10. [Comparisons of manual and automatic refractometry with subjective results].

    PubMed

    Wübbolt, I S; von Alven, S; Hülssner, O; Erb, C

    2006-11-01

    Refractometry is very important in everyday clinical practice. The aim of this study is to compare the precision of three objective methods of refractometry with subjective dioptometry (Phoropter). The objective methods with the smallest deviation to subjective refractometry results are evaluated. The objective methods/instruments used were retinoscopy, Prism Refractometer PR 60 (Rodenstock) and Auto Refractometer RM-A 7000 (Topcon). The results of monocular dioptometry (sphere, cylinder and axis) of each objective method were compared to the results of the subjective method. The examination was carried out on 178 eyes, which were divided into 3 age-related groups: 6 - 12 years (103 eyes), 13 - 18 years (38 eyes) and older than 18 years (37 eyes). All measurements were made in cycloplegia. The smallest standard deviation of the measurement error was found for the Auto Refractometer RM-A 7000. Both the PR 60 and retinoscopy had a clearly higher standard deviation. Furthermore, the RM-A 7000 showed in three and retinoscopy in four of the nine comparisons a significant bias in the measurement error. The Auto Refractometer provides measurements with the smallest deviation compared to the subjective method. Here it has to be taken into account that the measurements for the sphere have an average deviation of + 0.2 dpt. In comparison to retinoscopy the examination of children with the RM-A 7000 is difficult. An advantage of the Auto Refractometer is the fast and easy handling, so that measurements can be performed by medical staff.

  11. Adaptation or recovery after health shocks? Evidence using subjective and objective health measures.

    PubMed

    Baji, Petra; Bíró, Anikó

    2018-05-01

    In this paper, we analyse the effect of an onset of a health shock on subjective survival probability and compare it with objective survival probability and self-reported health measures. In particular, we are interested in whether expectations of people respond to health shocks and whether these follow the evolution of objective life expectations and self-reported health measures over time. Using longitudinal data from the Health and Retirement Study, we estimate fixed effects models of adaptation for the objective and subjective survival probabilities and for some self-reported health measures. The results show that after cancer diagnosis, conditional on surviving, both the objective and subjective longevity and self-reported health measures drift back to the before diagnosis trajectories. For stroke and heart attack, in spite of their persistent negative effect on survival, subjective life expectations and self-reported health measures seem to indicate only a transient effect of the health shock. The differences between the objective and subjective measures are in line with the concept of adaptation. We discuss the policy implications of our results. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Developing a Comparative Measure of the Learning Climate in Professional Schools

    ERIC Educational Resources Information Center

    Bowen, Donald D.; Kilmann, Ralph H.

    1975-01-01

    The Learning Climate Questionnaire (LCQ) compares the objective properties of schools with measures of overall student satisfaction. The validity of the instrument suggests its use for substantive research investigations into the organizational dynamics of professional schools. (Author/JR)

  13. Object-based warping: an illusory distortion of space within objects.

    PubMed

    Vickery, Timothy J; Chun, Marvin M

    2010-12-01

    Visual objects are high-level primitives that are fundamental to numerous perceptual functions, such as guidance of attention. We report that objects warp visual perception of space in such a way that spatial distances within objects appear to be larger than spatial distances in ground regions. When two dots were placed inside a rectangular object, they appeared farther apart from one another than two dots with identical spacing outside of the object. To investigate whether this effect was object based, we measured the distortion while manipulating the structure surrounding the dots. Object displays were constructed with a single object, multiple objects, a partially occluded object, and an illusory object. Nonobject displays were constructed to be comparable to object displays in low-level visual attributes. In all cases, the object displays resulted in a more powerful distortion of spatial perception than comparable non-object-based displays. These results suggest that perception of space within objects is warped.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scaduto, DA; Hu, Y-H; Zhao, W

    Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spreadmore » function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object-independent. Depth-direction spatial resolution may be measured directly using MTF or indirectly using ASF or SSP as surrogate measurements. While MTF is object-independent, it is invalid for nonlinear reconstructions.« less

  15. Objective and subjective measurement of sleep disturbance in female trauma survivors with posttraumatic stress disorder.

    PubMed

    Werner, Kimberly B; Griffin, Michael G; Galovski, Tara E

    2016-06-30

    Sleep disturbance may be the most often endorsed symptom of posttraumatic stress disorder (PTSD). Much of this research is based on subjective reports from trauma survivors; however, objective measures of sleep-related impairment have yielded findings inconsistent with self-report data. More studies investigating subjective and objective assessments concordantly are needed to understand sleep impairment in PTSD. The current study examined PTSD-related sleep disturbance in a female interpersonal violence cohort with full PTSD diagnoses (N=51) assessing subjective (global and daily diary measures) and objective (actigraphy) sleep measures concurrently. PTSD severity was positively associated with global, subjective reports of sleep impairment and insomnia. Subjective measures of sleep (including global sleep impairment, insomnia, and daily sleep diary reports of total sleep time, sleep efficiency, and sleep onset latency) were moderately to strongly correlated. However, no significant correlations between subjective and objective reports of sleep impairment were found in this cohort. Analyses demonstrated an overall elevation in subjectively reported sleep impairment when compared to objective measurement assessed concurrently. Findings demonstrate a lack of agreement between subjective and objective measurements of sleep in a PTSD-positive female cohort, suggesting objective and subjective sleep impairments are distinct sleep parameters that do not necessarily directly co-vary. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Differences in levels of physical activity between White and South Asian populations within a healthcare setting: impact of measurement type in a cross-sectional study

    PubMed Central

    Yates, Thomas; Henson, Joe; Edwardson, Charlotte; Bodicoat, Danielle H; Davies, Melanie J; Khunti, Kamlesh

    2015-01-01

    Objective We investigate differences between White and South Asian (SA) populations in levels of objectively measured and self-reported physical activity. Design Cross-sectional study. Setting Leicestershire, UK, 2010–2011. Participants Baseline data were pooled from two diabetes prevention trials that recruited a total of 4282 participants from primary care with a high risk score for type 2 diabetes. For this study, 2843 White (age=64±8, female=37%) and 243 SA (age=58±9, female=34%) participants had complete physical activity data and were included in the analysis. Outcome measures Moderate-intensity to vigorous-intensity physical activity (MVPA) and walking activity were measured using the International Physical Activity Questionnaire (IPAQ), and a combination of piezoelectric pedometer (NL-800) and accelerometer (Actigraph GT3X) were used to objectively measure physical activity. Results Compared to White participants, SA participants self-reported less MVPA (30 vs 51 min/day; p<0.001) and walking activity (11 vs 17 min/day; P=0.001). However, there was no difference in objectively measured ambulatory activity (5992 steps/day vs 6157 steps/day; p=0.75) or in time spent in MVPA (18.0 vs 21.5 min/day; p=0.23). Results were largely unaffected when adjusted for age, sex and social deprivation. Compared to accelerometer data, White participants overestimated their time in MVPA by 51 min/day and SA participants by 21 min/day. Conclusions SA and White groups undertook similar levels of physical activity when measured objectively despite self-reported estimates being around 40% lower in the SA group. This emphasises the limitations of comparing self-reported lifestyle measures across different populations and ethnic groups. Trial registration number Reports baseline data from: Walking Away from Type 2 Diabetes (ISRCTN31392913) and Let's Prevent Diabetes (NCT00677937). PMID:26204908

  17. Comparison of DNA fragmentation and color thresholding for objective quantitation of apoptotic cells

    NASA Technical Reports Server (NTRS)

    Plymale, D. R.; Ng Tang, D. S.; Fermin, C. D.; Lewis, D. E.; Martin, D. S.; Garry, R. F.

    1995-01-01

    Apoptosis is a process of cell death characterized by distinctive morphological changes and fragmentation of cellular DNA. Using video imaging and color thresholding techniques, we objectively quantitated the number of cultured CD4+ T-lymphoblastoid cells (HUT78 cells, RH9 subclone) displaying morphological signs of apoptosis before and after exposure to gamma-irradiation. The numbers of apoptotic cells measured by objective video imaging techniques were compared to numbers of apoptotic cells measured in the same samples by sensitive apoptotic assays that quantitate DNA fragmentation. DNA fragmentation assays gave consistently higher values compared with the video imaging assays that measured morphological changes associated with apoptosis. These results suggest that substantial DNA fragmentation can precede or occur in the absence of the morphological changes which are associated with apoptosis in gamma-irradiated RH9 cells.

  18. Reporting Florida's Annual Measurable Objectives (AMOs) in Compliance with ESEA Flexibility Requirements: Guide to Calculations for 2013-14

    ERIC Educational Resources Information Center

    Florida Department of Education, 2014

    2014-01-01

    This Annual Measurable Objective (AMO) is designed to keep Florida moving forward toward national and international competitiveness. Florida will compare its National Assessment of Educational Progress (NAEP) scores to those of the top five states and its Trends in International Mathematics and Science Study (TIMSS), Progress in International…

  19. Measurement of Physical Performance and Objective Fatigability in People with Mild-to-Moderate Traumatic Brain Injury

    ERIC Educational Resources Information Center

    Merritta, Catherine; Cherian, Binu; Macaden, Ashish S.; John, Judy Ann

    2010-01-01

    The aims of this study were to objectively measure the physical performance and physical endurance of patients with traumatic brain injury with minimization of cognitive and psychological fatigue, and to compare the physical performance of brain injured patients with that of healthy controls. This was a nonrandomized partially blinded controlled…

  20. Objective and quantitative definitions of modified food textures based on sensory and rheological methodology

    PubMed Central

    Wendin, Karin; Ekman, Susanne; Bülow, Margareta; Ekberg, Olle; Johansson, Daniel; Rothenberg, Elisabet; Stading, Mats

    2010-01-01

    Introduction Patients who suffer from chewing and swallowing disorders, i.e. dysphagia, may have difficulties ingesting normal food and liquids. In these patients a texture modified diet may enable that the patient maintain adequate nutrition. However, there is no generally accepted definition of ‘texture’ that includes measurements describing different food textures. Objective Objectively define and quantify categories of texture-modified food by conducting rheological measurements and sensory analyses. A further objective was to facilitate the communication and recommendations of appropriate food textures for patients with dysphagia. Design About 15 food samples varying in texture qualities were characterized by descriptive sensory and rheological measurements. Results Soups were perceived as homogenous; thickened soups were perceived as being easier to swallow, more melting and creamy compared with soups without thickener. Viscosity differed between the two types of soups. Texture descriptors for pâtés were characterized by high chewing resistance, firmness, and having larger particles compared with timbales and jellied products. Jellied products were perceived as wobbly, creamy, and easier to swallow. Concerning the rheological measurements, all solid products were more elastic than viscous (G′>G″), belonging to different G′ intervals: jellied products (low G′) and timbales together with pâtés (higher G′). Conclusion By combining sensory and rheological measurements, a system of objective, quantitative, and well-defined food textures was developed that characterizes the different texture categories. PMID:20592965

  1. Monitoring the athlete training response: subjective self-reported measures trump commonly used objective measures: a systematic review

    PubMed Central

    Saw, Anna E; Main, Luana C; Gastin, Paul B

    2016-01-01

    Background Monitoring athlete well-being is essential to guide training and to detect any progression towards negative health outcomes and associated poor performance. Objective (performance, physiological, biochemical) and subjective measures are all options for athlete monitoring. Objective We systematically reviewed objective and subjective measures of athlete well-being. Objective measures, including those taken at rest (eg, blood markers, heart rate) and during exercise (eg, oxygen consumption, heart rate response), were compared against subjective measures (eg, mood, perceived stress). All measures were also evaluated for their response to acute and chronic training load. Methods The databases Academic search complete, MEDLINE, PsycINFO, SPORTDiscus and PubMed were searched in May 2014. Fifty-six original studies reported concurrent subjective and objective measures of athlete well-being. The quality and strength of findings of each study were evaluated to determine overall levels of evidence. Results Subjective and objective measures of athlete well-being generally did not correlate. Subjective measures reflected acute and chronic training loads with superior sensitivity and consistency than objective measures. Subjective well-being was typically impaired with an acute increase in training load, and also with chronic training, while an acute decrease in training load improved subjective well-being. Summary This review provides further support for practitioners to use subjective measures to monitor changes in athlete well-being in response to training. Subjective measures may stand alone, or be incorporated into a mixed methods approach to athlete monitoring, as is current practice in many sport settings. PMID:26423706

  2. Early working memory as a racially and ethnically neutral measure of outcome in extremely preterm children at 18-22 months

    PubMed Central

    Lowe, Jean R.; Duncan, Andrea Freeman; Bann, Carla M.; Fuller, Janell; Hintz, Susan R.; Das, Abhik; Higgins, Rosemary D.; Watterberg, Kristi L.

    2013-01-01

    Background Difficulties with executive function has been found in preterm children, resulting in difficulties with learning and school performance. Aim This study evaluated the relationship of early working memory as measured by object permanence items to the cognitive and language scores on the Bayley Scales-III in a cohort of children born extremely preterm. Study Design Logistic regression models were conducted to compare object permanence scores derived from the Bayley Scales-III by race/ethnicity and maternal education, controlling for medical covariates. Subjects Extremely preterm toddlers (526), who were part of a Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network's multi-center study, were evaluated at 18-22 months corrected age. Outcome Measures Object permanence scores derived from the Bayley Developmental Scales were compared by race/ethnicity and maternal education, controlling for medical covariates. Results There were no significant differences in object permanence mastery and scores among the treatment groups after controlling for medical and social variables, including maternal education and race/ethnicity. Males and children with intraventricular hemorrhage, retinopathy of prematurity, and bronchopulmonary dysplasia were less likely to demonstrate object permanence mastery and had lower object permanence scores. Children who attained object permanence mastery had significantly higher Bayley Scales-III cognitive and language scores after controlling for medical and socio-economic factors. Conclusions Our measure of object permanence is free of influence from race, ethnic and socio-economic factors. Adding this simple task to current clinical practice could help detect early executive function difficulties in young children. PMID:23993309

  3. An Ergonomic Evaluation of Aircraft Pilot Seats

    NASA Astrophysics Data System (ADS)

    Andrade, Yolanda Nicole

    Seat comfort has become increasingly important in today's society as we spend more time at consoles, instrument panels, or just online. However, seat comfort is hard to define and difficult to measure. Several measures both objective and subjective were used to evaluate seat comfort in commercially available average pilot seats. Three pilot seats, which had the same material and similar adjustments but different physical attributes, and a universal classroom seat, with different material and no adjustments, were compared by 20 volunteers using subjective and objective measures in a Latin square controlled repeated measures design. A Friedman's test was used to determine that both the comfort questionnaire and the body-map rating results were able to discriminate objective comfort levels between the seats. One-way repeated measures ANOVA tests were used to analyze both the objective tests, actigraph and pressure pad data. All results indicated that one seat was clearly the most comfortable and another, the classroom seat was clearly the most uncomfortable seat. Furthermore, the overall comments per seat were compiled and compared to Fazlollahtabar's 2010) predictive automobile seat comfort theory to determine which factors influence comfort perception. The use of both subjective and objective data can better distinguish comfort from one seat over the other. These results have implications for future tests of seats that will be used for long durations. Limitations and future recommendations are discussed later in the paper. An interesting finding may explain why pressure pad data are typically seemingly at odds with subjective measures of seat comfort.

  4. Using the Bootstrap Method for a Statistical Significance Test of Differences between Summary Histograms

    NASA Technical Reports Server (NTRS)

    Xu, Kuan-Man

    2006-01-01

    A new method is proposed to compare statistical differences between summary histograms, which are the histograms summed over a large ensemble of individual histograms. It consists of choosing a distance statistic for measuring the difference between summary histograms and using a bootstrap procedure to calculate the statistical significance level. Bootstrapping is an approach to statistical inference that makes few assumptions about the underlying probability distribution that describes the data. Three distance statistics are compared in this study. They are the Euclidean distance, the Jeffries-Matusita distance and the Kuiper distance. The data used in testing the bootstrap method are satellite measurements of cloud systems called cloud objects. Each cloud object is defined as a contiguous region/patch composed of individual footprints or fields of view. A histogram of measured values over footprints is generated for each parameter of each cloud object and then summary histograms are accumulated over all individual histograms in a given cloud-object size category. The results of statistical hypothesis tests using all three distances as test statistics are generally similar, indicating the validity of the proposed method. The Euclidean distance is determined to be most suitable after comparing the statistical tests of several parameters with distinct probability distributions among three cloud-object size categories. Impacts on the statistical significance levels resulting from differences in the total lengths of satellite footprint data between two size categories are also discussed.

  5. ITEM SELECTION TECHNIQUES AND EVALUATION OF INSTRUCTIONAL OBJECTIVES.

    ERIC Educational Resources Information Center

    COX, RICHARD C.

    THE VALIDITY OF AN EDUCATIONAL ACHIEVEMENT TEST DEPENDS UPON THE CORRESPONDENCE BETWEEN SPECIFIED EDUCATIONAL OBJECTIVES AND THE EXTENT TO WHICH THESE OBJECTIVES ARE MEASURED BY THE EVALUATION INSTRUMENT. THIS STUDY IS DESIGNED TO EVALUATE THE EFFECT OF STATISTICAL ITEM SELECTION ON THE STRUCTURE OF THE FINAL EVALUATION INSTRUMENT AS COMPARED WITH…

  6. Observations Regarding Scatter Fraction and NEC Measurements for Small Animal PET

    NASA Astrophysics Data System (ADS)

    Yang, Yongfeng; Cherry, S. R.

    2006-02-01

    The goal of this study was to evaluate the magnitude and origin of scattered radiation in a small-animal PET scanner and to assess the impact of these findings on noise equivalent count rate (NECR) measurements, a metric often used to optimize scanner acquisition parameters and to compare one scanner with another. The scatter fraction (SF) was measured for line sources in air and line sources placed within a mouse-sized phantom (25 mm /spl phi//spl times/70 mm) and a rat-sized phantom (60 mm /spl phi//spl times/150 mm) on the microPET II small-animal PET scanner. Measurements were performed for lower energy thresholds ranging from 150-450 keV and a fixed upper energy threshold of 750 keV. Four different methods were compared for estimating the SF. Significant scatter fractions were measured with just the line source in the field of view, with the spatial distribution of these events consistent with scatter from the gantry and room environment. For mouse imaging, this component dominates over object scatter, and the measured SF is strongly method dependent. The environmental SF rapidly increases as the lower energy threshold decreases and can be more than 30% for an open energy window of 150-750 keV. The object SF originating from the mouse phantom is about 3-4% and does not change significantly as the lower energy threshold increases. The object SF for the rat phantom ranges from 10 to 35% for different energy windows and increases as the lower energy threshold decreases. Because the measured SF is highly dependent on the method, and there is as yet no agreed upon standard for animal PET, care must be exercised when comparing NECR for small objects between different scanners. Differences may be methodological rather than reflecting any relevant difference in the performance of the scanner. Furthermore, these results have implications for scatter correction methods when the majority of the detected scatter does not arise from the object itself.

  7. Validation of self-reported cannabis dose and potency: an ecological study.

    PubMed

    van der Pol, Peggy; Liebregts, Nienke; de Graaf, Ron; Korf, Dirk J; van den Brink, Wim; van Laar, Margriet

    2013-10-01

    To assess the reliability and validity of self-reported cannabis dose and potency measures. Cross-sectional study comparing self-reports with objective measures of amount of cannabis and delta-9-tetrahydrocannabinol (THC) concentration. Ecological study with assessments at participants' homes or in a coffee shop. Young adult frequent cannabis users (n = 106) from the Dutch Cannabis Dependence (CanDep) study. The objectively measured amount of cannabis per joint (dose in grams) was compared with self-reported estimates using a prompt card and average number of joints made from 1 g of cannabis. In addition, objectively assessed THC concentration in the participant's cannabis was compared with self-reported level of intoxication, subjective estimate of cannabis potency and price per gram of cannabis. Objective estimates of doses per joint (0.07-0.88 g/joint) and cannabis potency (1.1-24.7%) varied widely. Self-reported measures of dose were imprecise, but at group level, average dose per joint was estimated accurately with the number of joints made from 1 g [limit of agreement (LOA) = -0.02 g, 95% confidence interval (CI) = -0.29; 0.26], whereas the prompt card resulted in serious underestimation (LOA = 0.14 g, 95% CI = -0.10; 0.37). THC concentration in cannabis was associated with subjective potency ['average' 3.77% (P = 0.002) and '(very) strong' 5.13% more THC (P < 0.001) than '(very) mild' cannabis] and with cannabis price (about 1% increase in THC concentration per euro spent on 1 g of cannabis, P < 0.001), but not with level of intoxication. Self-report measures relating to cannabis use appear at best to be associated weakly with objective measures. Of the self-report measures, number of joints per gram, cannabis price and subjective potency have at least some validity. © 2013 Society for the Study of Addiction.

  8. Assessing the validity and reliability of self-report data on contraception use in the MObile Technology for Improved Family Planning (MOTIF) randomised controlled trial.

    PubMed

    Smith, Chris; Edwards, Phil; Free, Caroline

    2018-03-15

    A variety of different approaches to measuring contraceptive use have been used or proposed, either to assess current use or adherence over time, using subjective or objective measures. This paper reports an overview of approaches to measuring adherence to the oral contraceptive, intra-uterine device, sub-dermal implant, and injectable and describes how we assessed contraception use in the MObile Technology for Improved Family Planning (MOTIF) trial in Cambodia. We summarise and discuss advantages and disadvantages of different subjective and objective approaches to measuring adherence to the oral contraceptive, intra-uterine device, sub-dermal implant, and injectable such as self-reports, clinic records, electronic monitoring devices, clinical examination and biomarkers. For the MOTIF trial, we did not consider it feasible to measure objective contraception use as many participants lived a long distance from the clinic and we were concerned whether it was appropriate to ask women to return to clinic for a physical examination simply to verify self-report information already provided. We aimed to assess the validity of the four-month data with 50 participants, calculating the sensitivity and specificity of self-reported data compared with objective measurement. For the 46 valid measurements obtained, the sensitivity and specificity was 100% for self-reported contraception use compared to objective measurement but this study had some limitations. To assess reliability of self-report data we compared calendar data collected on effective contraception use at months 1-4 post-abortion, collected separately at four and 12 months. Agreement ranged from 80 to 84% with a kappa statistic ranging from 0·59 to 0·67 indicating fair to good agreement. There is no perfect method of assessing contraception use and researchers designing future studies should give consideration of what to measure, for example current use or detailed patterns of use over time, and remain mindful of what will be feasible and acceptable to the study population. Although self-reported data on contraception use are considered less reliable, and prone to social desirability bias, it is often the standard approach for contraception research and provides data comparable to previous studies. ClinicalTrials.gov Identifier: NCT01823861 . Registered: March 30, 2013.

  9. Deviation between self-reported and measured occupational physical activity levels in office employees: effects of age and body composition.

    PubMed

    Wick, Katharina; Faude, Oliver; Schwager, Susanne; Zahner, Lukas; Donath, Lars

    2016-05-01

    Whether occupational physical activity (PA) will be assessed via questionnaires or accelerometry depends on available resources. Although self-reported data collection seems feasible and inexpensive, obtained information could be biased by demographic determinants. Thus, we aimed at comparing self-reported and objectively measured occupational sitting, standing, and walking times adjusted for socio-demographic variables. Thirty-eight office employees (eight males, 30 females, age 40.8 ± 11.4 years, BMI 23.9 ± 4.2 kg/m(2)) supplied with height-adjustable working desks were asked to report sitting, standing, and walking times using the Occupational Sitting and Physical Activity Questionnaire during one working week. The ActiGraph wGT3X-BT was used to objectively measure occupational PA during the same week. Subjectively and objectively measured data were compared computing the intra-class correlation coefficients, paired t tests and Bland-Altman plots. Furthermore, repeated-measurement ANOVAs for measurement (subjective vs. objective) and socio-demographic variables were calculated. Self-reported data yielded a significant underestimation of standing time (13.3 vs. 17.9%) and an overestimation of walking time (12.7 vs. 5.0%). Significant interaction effects of age and measurement of standing time (F = 6.0, p = .02, ηp(2) = .14) and BMI group and measurement of walking time were found (F = 3.7, p = .04, ηp(2) = .17). Older employees (>39 years) underestimated their standing time, while underweight workers (BMI < 20 kg/m(2)) overestimated their walking time. Self-reported PA data differ from objective data. Demographic variables (age, BMI) affect the amount of self-reported misjudging of PA. In order to improve the validity of self-reported data, a correction formula for the economic assessment of PA by subjective measures is needed, considering age and BMI.

  10. Use of Objective Metrics in Dynamic Facial Reanimation: A Systematic Review.

    PubMed

    Revenaugh, Peter C; Smith, Ryan M; Plitt, Max A; Ishii, Lisa; Boahene, Kofi; Byrne, Patrick J

    2018-06-21

    Facial nerve deficits cause significant functional and social consequences for those affected. Existing techniques for dynamic restoration of facial nerve function are imperfect and result in a wide variety of outcomes. Currently, there is no standard objective instrument for facial movement as it relates to restorative techniques. To determine what objective instruments of midface movement are used in outcome measurements for patients treated with dynamic methods for facial paralysis. Database searches from January 1970 to June 2017 were performed in PubMed, Embase, Cochrane Library, Web of Science, and Scopus. Only English-language articles on studies performed in humans were considered. The search terms used were ("Surgical Flaps"[Mesh] OR "Nerve Transfer"[Mesh] OR "nerve graft" OR "nerve grafts") AND (face [mh] OR facial paralysis [mh]) AND (innervation [sh]) OR ("Face"[Mesh] OR facial paralysis [mh]) AND (reanimation [tiab]). Two independent reviewers evaluated the titles and abstracts of all articles and included those that reported objective outcomes of a surgical technique in at least 2 patients. The presence or absence of an objective instrument for evaluating outcomes of midface reanimation. Additional outcome measures were reproducibility of the test, reporting of symmetry, measurement of multiple variables, and test validity. Of 241 articles describing dynamic facial reanimation techniques, 49 (20.3%) reported objective outcome measures for 1898 patients. Of those articles reporting objective measures, there were 29 different instruments, only 3 of which reported all outcome measures. Although instruments are available to objectively measure facial movement after reanimation techniques, most studies do not report objective outcomes. Of objective facial reanimation instruments, few are reproducible and able to measure symmetry and multiple data points. To accurately compare objective outcomes in facial reanimation, a reproducible, objective, and universally applied instrument is needed.

  11. Objective measurements of activity patterns in people with newly diagnosed Type 2 diabetes demonstrate a sedentary lifestyle.

    PubMed

    Cichosz, S L; Fleischer, J; Hoeyem, P; Laugesen, E; Poulsen, P L; Christiansen, J S; Ejskjær, N; Hansen, T K

    2013-09-01

    To evaluate physical activity in people with newly diagnosed Type 2 diabetes using objective measures. We analysed data from a study aimed at assessing carotid femoral pulse wave velocity in which a piezoelectric accelerometer was worn by 100 people with newly diagnosed Type 2 diabetes and by 100 age- and sex-matched control subjects. Differences in physical activity patterns were investigated. Compared with the control group, the people with Type 2 diabetes spent significantly more time engaged in sedentary or lower level activities during the day, with a mean (sd) time of 926 (44) vs 898 (70) min, P < 0.001). This difference remained significant after correction for differences in BMI between the two groups. Using objective measurements, our findings demonstrate that people with newly diagnosed Type 2 diabetes have a more sedentary lifestyle compared with well-matched controls. © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.

  12. Robust dynamic 3-D measurements with motion-compensated phase-shifting profilometry

    NASA Astrophysics Data System (ADS)

    Feng, Shijie; Zuo, Chao; Tao, Tianyang; Hu, Yan; Zhang, Minliang; Chen, Qian; Gu, Guohua

    2018-04-01

    Phase-shifting profilometry (PSP) is a widely used approach to high-accuracy three-dimensional shape measurements. However, when it comes to moving objects, phase errors induced by the movement often result in severe artifacts even though a high-speed camera is in use. From our observations, there are three kinds of motion artifacts: motion ripples, motion-induced phase unwrapping errors, and motion outliers. We present a novel motion-compensated PSP to remove the artifacts for dynamic measurements of rigid objects. The phase error of motion ripples is analyzed for the N-step phase-shifting algorithm and is compensated using the statistical nature of the fringes. The phase unwrapping errors are corrected exploiting adjacent reliable pixels, and the outliers are removed by comparing the original phase map with a smoothed phase map. Compared with the three-step PSP, our method can improve the accuracy by more than 95% for objects in motion.

  13. Comparing Construct Definition in the Angoff and Objective Standard Setting Models: Playing in a House of Cards without a Full Deck

    ERIC Educational Resources Information Center

    Stone, Gregory Ethan; Koskey, Kristin L. K.; Sondergeld, Toni A.

    2011-01-01

    Typical validation studies on standard setting models, most notably the Angoff and modified Angoff models, have ignored construct development, a critical aspect associated with all conceptualizations of measurement processes. Stone compared the Angoff and objective standard setting (OSS) models and found that Angoff failed to define a legitimate…

  14. Methods for Assessing Sleep in Children with Autism Spectrum Disorders: A Review

    ERIC Educational Resources Information Center

    Hodge, Danelle; Parnell, Andrea M. N.; Hoffman, Charles D.; Sweeney, Dwight P.

    2012-01-01

    A literature review completed by Bauer and Blunden (2008) determined that compared to objective measures, subjective assessments of sleep for typically developing children (e.g., parental reports) were of limited utility. No comparable literature review has been undertaken to determine whether subjective measures are appropriate for assessing…

  15. Domain-Specific Self-Reported and Objectively Measured Physical Activity in Children.

    PubMed

    Sprengeler, Ole; Wirsik, Norman; Hebestreit, Antje; Herrmann, Diana; Ahrens, Wolfgang

    2017-03-01

    Little is known about the extent that different domains contribute to total sedentary (SED), light (LPA) and moderate-to-vigorous physical activity (MVPA). We aimed to identify domain-specific physical activity (PA) patterns in school-aged children who were assessed by questionnaire and accelerometry. For the study, 298 German school children and adolescents aged 6-17 years wore an accelerometer for one week and completed a PA recall-questionnaire for the same period. Spearman coefficients (r) were used to evaluate the agreement between self-reported and objectively measured PA in five domains (transport, school hours, physical education, leisure-time, organized sports activities). School hours mainly contributed to the total objectively measured SED, LPA and MVPA (55%, 53% and 46%, respectively), whilst sports activities contributed only 24% to total MVPA. Compared to accelerometry, the proportion of self-reported LPA and MVPA during school hours was substantially underestimated but overestimated during leisure-time. The agreement of self-reported and objectively measured PA was low for total LPA (r = 0.09, 95% CI (confidence interval): -0.03-0.20) and total MVPA (r = 0.21, 95% CI: 0.10-0.32), while moderate agreement was only found for total SED (r = 0.44, 95% CI: 0.34-0.53), LPA during transport (r = 0.59; 95% CI: 0.49-0.67) and MVPA during organized sports activities (r = 0.54; 95% CI: 0.38-0.67). Since school hours mainly contribute to total SED, LPA and MVPA and self-reported LPA and MVPA during school were importantly underestimated compared to objectively measured LPA and MVPA, the application of objective measurements is compulsory to characterize the entire activity pattern of school-aged children.

  16. Domain-Specific Self-Reported and Objectively Measured Physical Activity in Children

    PubMed Central

    Sprengeler, Ole; Wirsik, Norman; Hebestreit, Antje; Herrmann, Diana; Ahrens, Wolfgang

    2017-01-01

    Little is known about the extent that different domains contribute to total sedentary (SED), light (LPA) and moderate-to-vigorous physical activity (MVPA). We aimed to identify domain-specific physical activity (PA) patterns in school-aged children who were assessed by questionnaire and accelerometry. For the study, 298 German school children and adolescents aged 6–17 years wore an accelerometer for one week and completed a PA recall-questionnaire for the same period. Spearman coefficients (r) were used to evaluate the agreement between self-reported and objectively measured PA in five domains (transport, school hours, physical education, leisure-time, organized sports activities). School hours mainly contributed to the total objectively measured SED, LPA and MVPA (55%, 53% and 46%, respectively), whilst sports activities contributed only 24% to total MVPA. Compared to accelerometry, the proportion of self-reported LPA and MVPA during school hours was substantially underestimated but overestimated during leisure-time. The agreement of self-reported and objectively measured PA was low for total LPA (r = 0.09, 95% CI (confidence interval): −0.03–0.20) and total MVPA (r = 0.21, 95% CI: 0.10–0.32), while moderate agreement was only found for total SED (r = 0.44, 95% CI: 0.34–0.53), LPA during transport (r = 0.59; 95% CI: 0.49–0.67) and MVPA during organized sports activities (r = 0.54; 95% CI: 0.38–0.67). Since school hours mainly contribute to total SED, LPA and MVPA and self-reported LPA and MVPA during school were importantly underestimated compared to objectively measured LPA and MVPA, the application of objective measurements is compulsory to characterize the entire activity pattern of school-aged children. PMID:28257046

  17. On the correlation between objective measurements and subjectively felt disturbance from traffic

    NASA Technical Reports Server (NTRS)

    Lans, J.

    1981-01-01

    Measurements of traffic noise during the day were taken at 90 measurement points over the urban area of Vienna; in addition, the vehicle frequency ascertained at the individual measurement points was also noted. Results of these objective measurements or various characteristic single values derived from them are compared with the results of the environmental survey of 1973 on the subjective noise stress experienced within buildings but caused by outside factors. Suggestions for suitable measures to describe the traffic noise and to derive limit values are given considering the relationship between number of vehicles and noise and annoyance.

  18. Detection technique for artificially illuminated objects in the outer solar system and beyond.

    PubMed

    Loeb, Abraham; Turner, Edwin L

    2012-04-01

    Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10(-3). Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=-4, whereas artificially illuminated objects should exhibit α=-2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=-2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars.

  19. Temperament and Self-Soothing Behavior in Children: Object Attachment and Thumbsucking.

    ERIC Educational Resources Information Center

    Lehman, Elyse Brauch; And Others

    A new measure of temperament, Rothbart's Children's Behavior Questionnaire (CBQ), was used to compare children with attachments to objects and those without such attachments. Comparisons were used to determine whether temperament differences between children with and without a history of object attachment held for children with and without a…

  20. Accommodation modulates the individual difference between objective and subjective measures of the final convergence step response.

    PubMed

    Jainta, S; Hoormann, J; Jaschinski, W

    2009-03-01

    Measuring vergence eye movements with dichoptic nonius lines (subjectively) usually leads to an overestimation of the vergence state after a step response: a subjective vergence overestimation (SVO). We tried to reduce this SVO by presenting a vergence stimulus that decoupled vergence and accommodation during the step response, i.e. reduced the degree of 'forced vergence'. In a mirror-stereoscope, we estimated convergence step responses with nonius lines presented at 1000 ms after a disparity step-stimulus and compared it to objective recordings (EyeLink II; n = 6). We presented a vertical line, a cross/rectangle stimulus and a difference-of-gaussians (DOG) pattern. For 180 min arc step stimuli, the subjective measures revealed a larger final vergence response than the objective measure; for the vertical line this SVO was 20 min arc, while it was significantly smaller for the DOG (12 min arc). For 60 min arc step-responses, no overestimation was observed. Additionally, we measured accommodation, which changed more for the DOG-pattern compared with the line-stimulus; this relative increase correlated with the corresponding relative change of SVO (r = 0.77). Both findings (i.e. no overestimation for small steps and a weaker one for the DOG-pattern) reflect lesser conflicting demand on accommodation and vergence under 'forced-vergence' viewing; consequently, sensory compensation is reduced and subjective and objective measures of vergence step responses tend to agree.

  1. Measuring attention using induced motion.

    PubMed

    Gogel, W C; Sharkey, T J

    1989-01-01

    Attention was measured by means of its effect upon induced motion. Perceived horizontal motion was induced in a vertically moving test spot by the physical horizontal motion of inducing objects. All stimuli were in a frontoparallel plane. The induced motion vectored with the physical motion to produce a clockwise or counterclockwise tilt in the apparent path of motion of the test spot. Either a single inducing object or two inducing objects moving in opposite directions were used. Twelve observers were instructed to attend to or to ignore the single inducing object while fixating the test object and, when the two opposing inducing objects were present, to attend to one inducing object while ignoring the other. Tracking of the test spot was visually monitored. The tilt of the path of apparent motion of the test spot was measured by tactile adjustment of a comparison rod. It was found that the measured tilt was substantially larger when the single inducing object was attended rather than ignored. For the two inducing objects, attending to one while ignoring the other clearly increased the effectiveness of the attended inducing object. The results are analyzed in terms of the distinction between voluntary and involuntary attention. The advantages of measuring attention by its effect on induced motion as compared with the use of a precueing procedure, and a hypothesis regarding the role of attention in modifying perceived spatial characteristics are discussed.

  2. Hot flash report and measurement among Bangladeshi migrants, their London neighbors, and their community of origin.

    PubMed

    Sievert, L L; Begum, K; Sharmeen, T; Murphy, L; Whitcomb, B W; Chowdhury, O; Muttukrishna, S; Bentley, G R

    2016-12-01

    To examine hot flashes in relation to climate and activity patterns, and to compare subjective and objective hot flashes among Bangladeshi immigrants to London, their white London neighbors, and women still living in their community of origin, Sylhet, Bangladesh ("sedentees"). Ninety-five women, aged 40-55, wore the Biolog ambulatory hot flash monitor. Objective measurements and subjective hot flash reports were examined in relation to demographic, reproductive, anthropometric, and lifestyle variables; temperature and humidity at 12:00 and 18:00; and time spent on housework and cooking. Concordance of objective and subjective hot flashes was assessed by Kappa statistics and by sensitivity of hot flash classification. During the study period, Bangladeshi sedentees reported more subjective hot flashes (p < .05), but there was no difference in number of objective hot flashes. White Londoners were more likely to describe hot flashes on their face and neck compared to Bangladeshis (p < .05). Sedentees were more likely to describe hot flashes on their feet (p < .05). Postmenopausal status, increasing parity, and high levels of housework were significant determinants of subjective hot flashes, while ambient temperature and humidity were not. Measures of subjective/objective concordance were low but similar across groups (10-20%). The proportion of objective hot flashes that were also self-reported was lowest among immigrants. Hot flashes were not associated with warmer temperatures, but were associated with housework and with site-specific patterns of cooking. The number of objective hot flash measures did not differ, but differences in subjective experience suggest the influence of culture. © 2016 Wiley Periodicals, Inc.

  3. Comparison of measured and modeled radiation, heat and water vapor fluxes: FIFE pilot study

    NASA Technical Reports Server (NTRS)

    Blad, Blaine L.; Verma, Shashi B.; Hubbard, Kenneth G.; Starks, Patrick; Hays, Cynthia; Norman, John M.; Waltershea, Elizabeth

    1988-01-01

    The primary objectives of the 1985 study were to test the feasibility of using radio frequency receivers to collect data from automated weather stations and to evaluate the use of the data collected by the automated weather stations for modeling the fluxes of latent heat, sensible heat, and radiation over wheat. The model Cupid was used to calculate these fluxes which were compared with fluxes of these entities measured using micrometeorological techniques. The primary objectives of the 1986 study were to measure and model reflected and emitted radiation streams at a few locations within the First International Satellite Land-Surface Climatology Project Field Experiment (FIFE) site and to compare modeled and measured latent heat and sensible heat fluxes from the prairie vegetation.

  4. Working Memory Units Are All in Your Head: Factors That Influence Whether Features or Objects Are the Favored Units

    ERIC Educational Resources Information Center

    Vergauwe, Evie; Cowan, Nelson

    2015-01-01

    We compared two contrasting hypotheses of how multifeatured objects are stored in visual working memory (vWM); as integrated objects or as independent features. A new procedure was devised to examine vWM representations of several concurrently held objects and their features and our main measure was reaction time (RT), allowing an examination of…

  5. Radiographic angles in hallux valgus: Comparison between protractor and iPhone measurements.

    PubMed

    Meng, Hong-Zheng; Zhang, Wei-Lin; Li, Xiu-Cheng; Yang, Mao-Wei

    2015-08-01

    Radiographic angles are used to assess the severity of hallux valgus deformity, make preoperative plans, evaluate outcomes after surgery, and compare results between different methods. Traditionally, hallux valgus angle (HVA) has been measured by using a protractor and a marker pen with hardcopy radiographs. The main objective of this study is to compare HVA measurements performed using a smartphone and a traditional protractor. The secondary objective was to compare the time taken between those two methods. Six observers measured major HVA on 20 radiographs of hallux valgus deformity with both a standard protractor and an Apple iPhone. Four of the observers repeated the measurements at least a week after the original measurements. The mean absolute difference between pairs of protractor and smartphone measurements was 3.2°. The 95% confidence intervals for intra-observer variability were ±3.1° for the smartphone measurement and ±3.2° for the protractor method. The 95% confidence intervals for inter-observer variability were ±9.1° for the smartphone measurement and ±9.6° for the protractor measurement. We conclude that the smartphone is equivalent to the protractor for the accuracy of HVA measurement. But, the time taken in smartphone measurement was also reduced. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Subjective versus objective measures of tic severity in Tourette syndrome - The influence of environment.

    PubMed

    Barnea, Meirav; Benaroya-Milshtein, Noa; Gilboa-Sechtman, Eva; Woods, Douglas W; Piacentini, John; Fennig, Silvana; Apter, Alan; Steinberg, Tamar

    2016-08-30

    The objective of this study was to examine the influence of environmental challenges on tic expression by subjective and objective measures. The study group consisted of 41 children aged 6-18 years (M=10.15, SD=2.73) with a primary diagnosis of Tourette syndrome. Subjective measures included the Functional Assessment Interview developed for this study and three standard validated instruments. The objective measure was a video-recording of the patients in five daily-life situations: watching television, doing homework, being alone, receiving attention when ticcing, and talking to a stranger. In addition, the effect of premonitory urges on assessment of tic expression was evaluated. The associations between the subjective and objective measures of tic expression were moderate to low. A significantly higher number of tics were observed in the television situation, and a significantly lower number in the alone situation, compared to the other situations. Higher levels of premonitory urge were associated with greater awareness of objectively measured tic expression. In conclusion, tic expression is significantly influenced by the environment. Subjective measures of tic expression may be misleading. These results have implications for refining the clinical assessment of tics, improving research methodology, and developing new therapeutic strategies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Development of a Distance-to-Roadway Proximity Metric to Compare Near-Road Pollutant Levels to a Central Site Monitor

    EPA Science Inventory

    The primary objective of the Detroit Exposure and Aerosol Research Study (DEARS) was to compare air pollutant concentrations measured at various neighborhoods, or exposure monitoring areas (EMAs), throughout a major metropolitan area to levels measured at a central site or commun...

  8. Executive function in fibromyalgia: Comparing subjective and objective measures.

    PubMed

    Gelonch, Olga; Garolera, Maite; Valls, Joan; Rosselló, Lluís; Pifarré, Josep

    2016-04-01

    There is evidence to suggest the existence of an executive dysfunction in people diagnosed with fibromyalgia, although there are certain inconsistencies between studies. Here, we aim to compare executive performance between patients with fibromyalgia and a control group by using subjective and objective cognitive tests, analyzing the influence of patient mood on the results obtained, and studying associations between the two measures. 82 patients diagnosed with fibromyalgia and 42 healthy controls, matched by age and years of education, were assessed using the Behavioral Rating Inventory of Executive Function - Adult Version (BRIEF-A) as a subjective measure of executive functioning. A selection of objective cognitive tests were also used to measure a series of executive functions and to identify symptoms of depression and anxiety. Patients with fibromyalgia perceived greater difficulties than the control group on all of the BRIEF-A scales. However, after adjustments were made for depression and anxiety the only differences that remained were those associated with the working memory scale and the Metacognition and Global Executive Composite index. In the case of the objective cognitive tests, a significantly worse overall performance was evidenced for the fibromyalgia patients. However, this also disappeared when adjustments were made for depression and anxiety. After this adjustment, fibromyalgia patients only performed significantly worse for the interference effect in the Stroop Test. Although there were no significant associations between most of the objective cognitive tests and the BRIEF-A scales, depression and anxiety exhibited strong associations with almost all of the BRIEF-A scales and with several of the objective cognitive tests. Patients with fibromyalgia showed executive dysfunction in subjective and objective measures, although most of this impairment was associated with mood disturbances. Exceptions to this general rule were observed in the impairment of working memory evidenced on the BRIEF-A scale and the inhibition impairment exhibited by the interference effect from the Stroop Test. The two types of measurement provide different yet complementary information. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Objective-subjective disparity in cancer-related cognitive impairment: does the use of change measures help reconcile the difference?

    PubMed

    O'Farrell, Erin; Smith, Andra; Collins, Barbara

    2017-10-01

    Studies to date have found little correlation between subjective and objective measures of cognitive function in cancer patients, making it difficult to interpret the significance of their cognitive complaints. The purpose of this study was to determine if a stronger correlation would be obtained using measures of cognitive change rather than static scores. Sixty women with early stage breast cancer underwent repeated cognitive assessment over the course of chemotherapy with a neuropsychological test battery (objective measure) and with the FACT-Cog (subjective measure). Their results were compared to 60 healthy women matched on age and education and assessed at similar intervals. We used multilevel modeling, with FACT-Cog as the dependent measure and ordinary least squares slopes of a neuropsychological summary score as the independent variable, to evaluate the co-variation between the subjective and objective measures over time RESULTS: Measures of both objective and subjective cognitive function declined over the course of chemotherapy in the breast cancer patients but there was no significant relationship between them, even when using change measures. Change in objective cognitive function was not related to change in anxiety or fatigue scores but the decline in perceived cognitive function was associated with greater anxiety and fatigue. The discrepancy in objective and subjective measures of cognition in breast cancer patients cannot be accounted for in terms of a failure to use change measures. Although the results are negative, we contend that this is the more appropriate methodology for analyzing cancer-related changes in cognition. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Height Measuring System On Video Using Otsu Method

    NASA Astrophysics Data System (ADS)

    Sandy, C. L. M.; Meiyanti, R.

    2017-01-01

    A measurement of height is comparing the value of the magnitude of an object with a standard measuring tool. The problems that exist in the measurement are still the use of a simple apparatus in which one of them is by using a meter. This method requires a relatively long time. To overcome these problems, this research aims to create software with image processing that is used for the measurement of height. And subsequent that image is tested, where the object captured by the video camera can be known so that the height of the object can be measured using the learning method of Otsu. The system was built using Delphi 7 of Vision Lab VCL 4.5 component. To increase the quality of work of the system in future research, the developed system can be combined with other methods.

  11. A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

    NASA Technical Reports Server (NTRS)

    Decker, A. J.; Stricker, J.

    1985-01-01

    Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD*P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

  12. Kinematic measurement from panned cinematography.

    PubMed

    Gervais, P; Bedingfield, E W; Wronko, C; Kollias, I; Marchiori, G; Kuntz, J; Way, N; Kuiper, D

    1989-06-01

    Traditional 2-D cinematography has used a stationary camera with its optical axis perpendicular to the plane of motion. This method has constrained the size of the object plane or has introduced potential errors from a small subject image size with large object field widths. The purpose of this study was to assess a panning technique that could overcome the inherent limitations of small object field widths, small object image sizes and limited movement samples. The proposed technique used a series of reference targets in the object field that provided the necessary scales and origin translations. A 102 m object field was panned. Comparisons between criterion distances and film measured distances for field widths of 46 m and 22 m resulted in absolute mean differences that were comparable to that of the traditional method.

  13. Objective and quantitative definitions of modified food textures based on sensory and rheological methodology.

    PubMed

    Wendin, Karin; Ekman, Susanne; Bülow, Margareta; Ekberg, Olle; Johansson, Daniel; Rothenberg, Elisabet; Stading, Mats

    2010-06-28

    Patients who suffer from chewing and swallowing disorders, i.e. dysphagia, may have difficulties ingesting normal food and liquids. In these patients a texture modified diet may enable that the patient maintain adequate nutrition. However, there is no generally accepted definition of 'texture' that includes measurements describing different food textures. Objectively define and quantify categories of texture-modified food by conducting rheological measurements and sensory analyses. A further objective was to facilitate the communication and recommendations of appropriate food textures for patients with dysphagia. About 15 food samples varying in texture qualities were characterized by descriptive sensory and rheological measurements. Soups were perceived as homogenous; thickened soups were perceived as being easier to swallow, more melting and creamy compared with soups without thickener. Viscosity differed between the two types of soups. Texture descriptors for pâtés were characterized by high chewing resistance, firmness, and having larger particles compared with timbales and jellied products. Jellied products were perceived as wobbly, creamy, and easier to swallow. Concerning the rheological measurements, all solid products were more elastic than viscous (G'>G''), belonging to different G' intervals: jellied products (low G') and timbales together with pâtés (higher G'). By combining sensory and rheological measurements, a system of objective, quantitative, and well-defined food textures was developed that characterizes the different texture categories.

  14. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor

    PubMed Central

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L.; Minassian, Arpi

    2016-01-01

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. PMID:27138818

  15. Analysis of aerobatic aircraft noise using the FAA's Integrated Noise Model

    DOT National Transportation Integrated Search

    2012-09-30

    This project has three main objectives. The first objective is to model noise from complete aerobatic routines for a range of aircraft. The second is to compare modeled and previously measured aircraft noise from complete aerobatic routines for a ran...

  16. Event-related potentials during word mapping to object shape predict toddlers' vocabulary size

    PubMed Central

    Borgström, Kristina; Torkildsen, Janne von Koss; Lindgren, Magnus

    2015-01-01

    What role does attention to different object properties play in early vocabulary development? This longitudinal study using event-related potentials in combination with behavioral measures investigated 20- and 24-month-olds' (n = 38; n = 34; overlapping n = 24) ability to use object shape and object part information in word-object mapping. The N400 component was used to measure semantic priming by images containing shape or detail information. At 20 months, the N400 to words primed by object shape varied in topography and amplitude depending on vocabulary size, and these differences predicted productive vocabulary size at 24 months. At 24 months, when most of the children had vocabularies of several hundred words, the relation between vocabulary size and the N400 effect in a shape context was weaker. Detached object parts did not function as word primes regardless of age or vocabulary size, although the part-objects were identified behaviorally. The behavioral measure, however, also showed relatively poor recognition of the part-objects compared to the shape-objects. These three findings provide new support for the link between shape recognition and early vocabulary development. PMID:25762957

  17. Kwajalein Infrastructure Prioritization Methodology

    DTIC Science & Technology

    2012-07-01

    Kwajalein are failing apart and if not fixed they could hinder or ruin the base’s ability to execute their mission. The proposed model ranks different ...their perspectives. Multiple Objective Decision Analysis (MODA) was conducted to compare the different value measures together. Since each value...measure is rated differently , it would be difficult to compare them to one another if there was no way to bring them under one type of measurement or unit

  18. Development and preliminary testing of an instrumented object for force analysis during grasping.

    PubMed

    Romeo, R A; Cordella, F; Zollo, L; Formica, D; Saccomandi, P; Schena, E; Carpino, G; Davalli, A; Sacchetti, R; Guglielmelli, E

    2015-01-01

    This paper presents the design and realization of an instrumented object for force analysis during grasping. The object, with spherical shape, has been constructed with three contact areas in order to allow performing a tripod grasp. Force Sensing Resistor (FSR) sensors have been employed for normal force measurements, while an accelerometer has been used for slip detection. An electronic board for data acquisition has been embedded into the object, so that only the cables for power supply exit from it. Validation tests have been carried out for: (i) comparing the force measurements with a ground truth; (ii) assessing the capability of the accelerometer to detect slippage for different roughness values; (iii) evaluating object performance in grasp trials performed by a human subject.

  19. Accuracy of self-reported sleep parameters compared with actigraphy in young people with mental ill-health.

    PubMed

    Biddle, Daniel J; Robillard, Rébecca; Hermens, Daniel F; Hickie, Ian B; Glozier, Nicholas

    2015-09-01

    Validation of self-report assessment of habitual sleep duration and onset time in young people with mental ill-health. Validation sample. Specialized early intervention centers for young people in Sydney, Australia. One hundred and forty-six young people with mental ill-health. N/A. Self-reported habitual sleep duration and onset time were compared against at least 7 days of actigraphy monitoring. Average bias in and calibration of subjective measures were assessed, along with correlation of subjective and objective measures. Differences by age, sex, mental-disorder type, and reported insomnia were also explored. On average, subjective estimates of sleep were unbiased. Overall, each additional hour of objective habitual sleep duration predicted 41 minutes more subjective habitual sleep duration, and each hour later objective habitual sleep onset occurred predicted a 43-minute later subjective habitual sleep onset. There were subgroup differences: subjective habitual sleep duration in self-reported insomnia was shorter than objective duration by 30 minutes (SD = 119), on average. Calibration of habitual sleep duration was worse for those with mood disorders than with other primary diagnoses (t = -2.39, P = .018). Correlation between subjective and objective measures was strong for sleep onset time (Á = .667, P < .001) and moderate for sleep duration (r = .332, P < .001). For the mood disorder group, subjective and objective sleep durations were uncorrelated. Self-reports seem valid for large-scale studies of habitual sleep duration and onset in help-seeking young people, but assessment of habitual sleep duration requires objective measures where individual accuracy is important. Copyright © 2015 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  20. Measurement of adhesion properties between topcoat paint and metallized/galvanized steel with surface energy measurement equipment.

    DOT National Transportation Integrated Search

    2013-09-01

    The objectives of this research project are: (1) Compare the adhesion properties of NEPCOAT-approved topcoat paint over : metallized or galvanized steel. Use surface-energy measuring technique to characterize the wetting properties of the liqui...

  1. Early working memory as a racially and ethnically neutral measure of outcome in extremely preterm children at 18-22 months.

    PubMed

    Lowe, Jean R; Duncan, Andrea Freeman; Bann, Carla M; Fuller, Janell; Hintz, Susan R; Das, Abhik; Higgins, Rosemary D; Watterberg, Kristi L

    2013-12-01

    Difficulties with executive function have been found in preterm children, resulting in difficulties with learning and school performance. This study evaluated the relationship of early working memory as measured by object permanence items to the cognitive and language scores on the Bayley Scales-III in a cohort of children born extremely preterm. Logistic regression models were conducted to compare object permanence scores derived from the Bayley Scales-III by race/ethnicity and maternal education, controlling for medical covariates. Extremely preterm toddlers (526), who were part of a Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network's multi-center study, were evaluated at 18-22 months corrected age. Object permanence scores derived from the Bayley Developmental Scales were compared by race/ethnicity and maternal education, controlling for medical covariates. There were no significant differences in object permanence mastery and scores among the treatment groups after controlling for medical and social variables, including maternal education and race/ethnicity. Males and children with intraventricular hemorrhage, retinopathy of prematurity, and bronchopulmonary dysplasia were less likely to demonstrate object permanence mastery and had lower object permanence scores. Children who attained object permanence mastery had significantly higher Bayley Scales-III cognitive and language scores after controlling for medical and socio-economic factors. Our measure of object permanence is free of influence from race, ethnic and socio-economic factors. Adding this simple task to current clinical practice could help detect early executive function difficulties in young children. Published by Elsevier Ireland Ltd.

  2. Comparing Measures of General and Abdominal Adiposity as Predictors of Blood Pressure in College Students

    ERIC Educational Resources Information Center

    Abshire, Demetrius A.; Mudd-Martin, Gia; Moser, Debra K.; Lennie, Terry A.

    2018-01-01

    Objective: To compare anthropometric measures of body mass index (BMI), waist circumference (WC), waist-to-height ratio (WHtR), and sagittal abdominal diameter (SAD) as predictors of blood pressure in college students. Participants: Students (N = 116) were recruited from November 2012 to May 2014 at an urban university and rural community…

  3. The measurement of ultrasound scattering from individual micron-sized objects and its application in single cell scattering.

    PubMed

    Falou, Omar; Rui, Min; El Kaffas, Ahmed; Kumaradas, J Carl; Kolios, Michael C

    2010-08-01

    The measurement of the ultrasound backscatter from individual micron-sized objects such as cells is required for various applications such as tissue characterization. However, performing such a measurement remains a challenge. For example, the presence of air bubbles in a suspension of cells during the measurements may lead to the incorrect interpretation of the acoustic signals. This work introduces a technique for measuring the ultrasound backscatter from individual micron-sized objects by combining a microinjection system with a co-registered optical microscope and an ultrasound imaging device. This allowed the measurement of the ultrasound backscatter response from a single object under optical microscope guidance. The optical and ultrasonic data were used to determine the size of the object and to deduce its backscatter responses, respectively. In order to calibrate the system, the backscatter frequency responses from polystyrene microspheres were measured and compared to theoretical predictions. A very good agreement was found between the measured backscatter responses of individual microspheres and theoretical predictions of an elastic sphere. The backscatter responses from single OCI-AML-5 cells were also investigated. It was found that the backscatter responses from AML cells are best modeled using the fluid sphere model. The advantages, limitations, and future applications of the developed technique are discussed.

  4. Vibration mode imaging.

    PubMed

    Zhang, Xiaoming; Zeraati, Mohammad; Kinnick, Randall R; Greenleaf, James F; Fatemi, Mostafa

    2007-06-01

    A new method for imaging the vibration mode of an object is investigated. The radiation force of ultrasound is used to scan the object at a resonant frequency of the object. The vibration of the object is measured by laser and the resulting acoustic emission from the object is measured by a hydrophone. It is shown that the measured signal is proportional to the value of the mode shape at the focal point of the ultrasound beam. Experimental studies are carried out on a mechanical heart valve and arterial phantoms. The mode images on the valve are made by the hydrophone measurement and confirmed by finite-element method simulations. Compared with conventional B-scan imaging on arterial phantoms, the mode imaging can show not only the interface of the artery and the gelatin, but also the vibration modes of the artery. The images taken on the phantom surface suggest that an image of an interior artery can be made by vibration measurements on the surface of the body. However, the image of the artery can be improved if the vibration of the artery is measured directly. Imaging of the structure in the gelatin or tissue can be enhanced by small bubbles and contrast agents.

  5. Validity of questionnaire self‐reports on computer, mouse and keyboard usage during a four‐week period

    PubMed Central

    Mikkelsen, Sigurd; Vilstrup, Imogen; Lassen, Christina Funch; Kryger, Ann Isabel; Thomsen, Jane Frølund; Andersen, Johan Hviid

    2007-01-01

    Objective To examine the validity and potential biases in self‐reports of computer, mouse and keyboard usage times, compared with objective recordings. Methods A study population of 1211 people was asked in a questionnaire to estimate the average time they had worked with computer, mouse and keyboard during the past four working weeks. During the same period, a software program recorded these activities objectively. The study was part of a one‐year follow‐up study from 2000–1 of musculoskeletal outcomes among Danish computer workers. Results Self‐reports on computer, mouse and keyboard usage times were positively associated with objectively measured activity, but the validity was low. Self‐reports explained only between a quarter and a third of the variance of objectively measured activity, and were even lower for one measure (keyboard time). Self‐reports overestimated usage times. Overestimation was large at low levels and declined with increasing levels of objectively measured activity. Mouse usage time proportion was an exception with a near 1:1 relation. Variability in objectively measured activity, arm pain, gender and age influenced self‐reports in a systematic way, but the effects were modest and sometimes in different directions. Conclusion Self‐reported durations of computer activities are positively associated with objective measures but they are quite inaccurate. Studies using self‐reports to establish relations between computer work times and musculoskeletal pain could be biased and lead to falsely increased or decreased risk estimates. PMID:17387136

  6. Temperature grid sensor for the measurement of spatial temperature distributions at object surfaces.

    PubMed

    Schäfer, Thomas; Schubert, Markus; Hampel, Uwe

    2013-01-25

    This paper presents results of the development and application of a new temperature grid sensor based on the wire-mesh sensor principle. The grid sensor consists of a matrix of 256 Pt1000 platinum chip resistors and an associated electronics that measures the grid resistances with a multiplexing scheme at high speed. The individual sensor elements can be spatially distributed on an object surface and measure transient temperature distributions in real time. The advantage compared with other temperature field measurement approaches such as infrared cameras is that the object under investigation can be thermally insulated and the radiation properties of the surface do not affect the measurement accuracy. The sensor principle is therefore suited for various industrial monitoring applications. Its applicability for surface temperature monitoring has been demonstrated through heating and mixing experiments in a vessel.

  7. The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial

    PubMed Central

    Feger, Sarah; Rief, Matthias; Zimmermann, Elke; Martus, Peter; Schuijf, Joanne Désirée; Blobel, Jörg; Richter, Felicitas; Dewey, Marc

    2015-01-01

    Purpose The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA), reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D) and compared to filtered back projection (FBP) with quantum denoising software (QDS). Methods Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contour sharpness) was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal. Results Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p≤0.001 at 20/21 measurement points; compared with FBP/QDS). Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP. Conclusions On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness. Trial Registration Clinicaltrials.gov NCT00967876 PMID:25945924

  8. Validation of time to task performance assessment method in simulation: A comparative design study.

    PubMed

    Shinnick, Mary Ann; Woo, Mary A

    2018-05-01

    There is a lack of objective and valid measures for assessing nursing clinical competence which could adversely impact patient safety. Therefore, we evaluated an objective assessment of clinical competence, Time to Task (ability to perform specific, critical nursing care activities within 5 min), and compared it to two subjective measures, (Lasater Clinical Judgement Rubric [LCJR] and common "pass/fail" assessment). Using a prospective, "Known Groups" (Expert vs. Novice nurses) comparative design, Expert nurses (ICU nurses with >5 years of ICU experience) and Novice nurses (senior prelicensure nursing students) participated individually in a simulation of a patient in decompensated heart failure. Fourteen nursing instructors or preceptors, blinded to group assignment, reviewed 28 simulation videos (15 Expert and 13 Novice) and scored them using the LCJR and pass/fail assessments. Time to Task assessment was scored based on time thresholds for specific nursing actions prospectively set by an expert clinical panel. Statistical analysis consisted of Medians Test and sensitivity and specificity analyses. The LCJR total score was significantly different between Experts and Novices (p < 0.01) and revealed adequate sensitivity (ability to correctly identify "Expert" nurses; 0.72) but had a low specificity (ability to correctly identify "Novice" nurses; 0.40). For the subjective measure 'pass/fail', sensitivity was high (0.90) but specificity was low (0.47). The Time to Task measure had statistical significance between Expert and Novice groups (p < 0.01) and sensitivity (0.80) and specificity (0.85) were good. Commonly used subjective measures of clinical nursing competence have difficulties with achieving acceptable specificity. However, an objective measure, Time to Task, had good sensitivity and specificity in differentiating between groups. While more than one assessment instrument should be used to determine nurse competency, an objective measure, such as Time to Task, warrants further study. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Validity of self-reported solar UVR exposure compared with objectively measured UVR exposure.

    PubMed

    Glanz, Karen; Gies, Peter; O'Riordan, David L; Elliott, Tom; Nehl, Eric; McCarty, Frances; Davis, Erica

    2010-12-01

    Reliance on verbal self-report of solar exposure in skin cancer prevention and epidemiologic studies may be problematic if self-report data are not valid due to systematic errors in recall, social desirability bias, or other reasons. This study examines the validity of self-reports of exposure to ultraviolet radiation (UVR) compared to objectively measured exposure among children and adults in outdoor recreation settings in 4 regions of the United States. Objective UVR exposures of 515 participants were measured using polysulfone film badge UVR dosimeters on 2 days. The same subjects provided self-reported UVR exposure data on surveys and 4-day sun exposure diaries, for comparison to their objectively measured exposure. Dosimeter data showed that lifeguards had the greatest UVR exposure (24.5% of weekday ambient UVR), children the next highest exposures (10.3% ambient weekday UVR), and parents had the lowest (6.6% ambient weekday UVR). Similar patterns were observed in self-report data. Correlations between diary reports and dosimeter findings were fair to good and were highest for lifeguards (r = 0.38-0.57), followed by parents (r = 0.28-0.29) and children (r = 0.18-0.34). Correlations between survey and diary measures were moderate to good for lifeguards (r = 0.20-0.54) and children (r = 0.35-0.53). This is the largest study of its kind to date, and supports the utility of self-report measures of solar UVR exposure. Overall, self-reports of sun exposure produce valid measures of UVR exposure among parents, children, and lifeguards who work outdoors. ©2010 AACR.

  10. Young drivers' responses to anti-speeding advertisements: Comparison of self-report and objective measures of persuasive processing and outcomes.

    PubMed

    Kaye, Sherrie-Anne; Lewis, Ioni; Algie, Jennifer; White, Melanie J

    2016-05-18

    Self-report measures are typically used to assess the effectiveness of road safety advertisements. However, psychophysiological measures of persuasive processing (i.e., skin conductance response [SCR]) and objective driving measures of persuasive outcomes (i.e., in-vehicle Global Positioning System [GPS] devices) may provide further insights into the effectiveness of these advertisements. This study aimed to explore the persuasive processing and outcomes of 2 anti-speeding advertisements by incorporating both self-report and objective measures of speeding behavior. In addition, this study aimed to compare the findings derived from these different measurement approaches. Young drivers (N = 20, M age = 21.01 years) viewed either a positive or negative emotion-based anti-speeding television advertisement. While viewing the advertisement, SCR activity was measured to assess ad-evoked arousal responses. The RoadScout GPS device was then installed in participants' vehicles for 1 week to measure on-road speed-related driving behavior. Self-report measures assessed persuasive processing (emotional and arousal responses) and actual driving behavior. There was general correspondence between the self-report measures of arousal and the SCR and between the self-report measure of actual driving behavior and the objective driving data (as assessed via the GPS devices). This study provides insights into how psychophysiological and GPS devices could be used as objective measures in conjunction with self-report measures to further understand the persuasive processes and outcomes of emotion-based anti-speeding advertisements.

  11. Sex and spatial position effects on object location memory following intentional learning of object identities.

    PubMed

    Alexander, Gerianne M; Packard, Mark G; Peterson, Bradley S

    2002-01-01

    Memory for object location relative both to veridical center (left versus right visual hemispace) and to eccentricity (central versus peripheral objects) was measured in 26 males and 25 females using the Silverman and Eals Location Memory Task. A subset of participants (17 males and 13 females) also completed a measure of implicit learning, the mirror-tracing task. No sex differences were observed in memory for object identities. Further, in both sexes, memory for object locations was better for peripherally located objects than for centrally located objects. In contrast to these similarities in female and male task performance, females but not males showed better recovery of object locations in the right compared to the left visual hemispace. Moreover, memory for object locations in the right hemispace was associated with mirror-tracing performance in women but not in men. Together, these data suggest that the processing of object features and object identification in the left cerebral hemisphere may include processing of spatial information that may contribute to superior object location memory in females relative to males.

  12. Object tracking using plenoptic image sequences

    NASA Astrophysics Data System (ADS)

    Kim, Jae Woo; Bae, Seong-Joon; Park, Seongjin; Kim, Do Hyung

    2017-05-01

    Object tracking is a very important problem in computer vision research. Among the difficulties of object tracking, partial occlusion problem is one of the most serious and challenging problems. To address the problem, we proposed novel approaches to object tracking on plenoptic image sequences. Our approaches take advantage of the refocusing capability that plenoptic images provide. Our approaches input the sequences of focal stacks constructed from plenoptic image sequences. The proposed image selection algorithms select the sequence of optimal images that can maximize the tracking accuracy from the sequence of focal stacks. Focus measure approach and confidence measure approach were proposed for image selection and both of the approaches were validated by the experiments using thirteen plenoptic image sequences that include heavily occluded target objects. The experimental results showed that the proposed approaches were satisfactory comparing to the conventional 2D object tracking algorithms.

  13. COMPARISON OF NONLINEAR DYNAMICS OPTIMIZATION METHODS FOR APS-U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Y.; Borland, Michael

    Many different objectives and genetic algorithms have been proposed for storage ring nonlinear dynamics performance optimization. These optimization objectives include nonlinear chromaticities and driving/detuning terms, on-momentum and off-momentum dynamic acceptance, chromatic detuning, local momentum acceptance, variation of transverse invariant, Touschek lifetime, etc. In this paper, the effectiveness of several different optimization methods and objectives are compared for the nonlinear beam dynamics optimization of the Advanced Photon Source upgrade (APS-U) lattice. The optimized solutions from these different methods are preliminarily compared in terms of the dynamic acceptance, local momentum acceptance, chromatic detuning, and other performance measures.

  14. A Theoretical and Empirical Comparison of Three Approaches to Achievement Testing.

    ERIC Educational Resources Information Center

    Haladyna, Tom; Roid, Gale

    Three approaches to the construction of achievement tests are compared: construct, operational, and empirical. The construct approach is based upon classical test theory and measures an abstract representation of the instructional objectives. The operational approach specifies instructional intent through instructional objectives, facet design,…

  15. Geophysics-based method of locating a stationary earth object

    DOEpatents

    Daily, Michael R [Albuquerque, NM; Rohde, Steven B [Corrales, NM; Novak, James L [Albuquerque, NM

    2008-05-20

    A geophysics-based method for determining the position of a stationary earth object uses the periodic changes in the gravity vector of the earth caused by the sun- and moon-orbits. Because the local gravity field is highly irregular over a global scale, a model of local tidal accelerations can be compared to actual accelerometer measurements to determine the latitude and longitude of the stationary object.

  16. The Objective Assessment of Cough Frequency in Bronchiectasis.

    PubMed

    Spinou, Arietta; Lee, Kai K; Sinha, Aish; Elston, Caroline; Loebinger, Michael R; Wilson, Robert; Chung, Kian Fan; Yousaf, Nadia; Pavord, Ian D; Matos, Sergio; Garrod, Rachel; Birring, Surinder S

    2017-10-01

    Cough in bronchiectasis is associated with significant impairment in health status. This study aimed to quantify cough frequency objectively with a cough monitor and investigate its relationship with health status. A secondary aim was to identify clinical predictors of cough frequency. Fifty-four patients with bronchiectasis were compared with thirty-five healthy controls. Objective 24-h cough, health status (cough-specific: Leicester Cough Questionnaire LCQ and bronchiectasis specific: Bronchiectasis Health Questionnaire BHQ), cough severity and lung function were measured. The clinical predictors of cough frequency in bronchiectasis were determined in a multivariate analysis. Objective cough frequency was significantly raised in patients with bronchiectasis compared to healthy controls [geometric mean (standard deviation)] 184.5 (4.0) vs. 20.6 (3.2) coughs/24-h; mean fold-difference (95% confidence interval) 8.9 (5.2, 15.2); p < 0.001 and they had impaired health status. There was a significant correlation between objective cough frequency and subjective measures; LCQ r = -0.52 and BHQ r = -0.62, both p < 0.001. Sputum production, exacerbations (between past 2 weeks to 12 months) and age were significantly associated with objective cough frequency in multivariate analysis, explaining 52% of the variance (p < 0.001). There was no statistically significant association between cough frequency and lung function. Cough is a common and significant symptom in patients with bronchiectasis. Sputum production, exacerbations and age, but not lung function, were independent predictors of cough frequency. Ambulatory objective cough monitoring provides novel insights and should be further investigated as an outcome measure in bronchiectasis.

  17. Secular Extragalactic Parallax and Geometric Distances with Gaia Proper Motions

    NASA Astrophysics Data System (ADS)

    Paine, Jennie; Darling, Jeremiah K.

    2018-06-01

    The motion of the Solar System with respect to the cosmic microwave background (CMB) rest frame creates a well measured dipole in the CMB, which corresponds to a linear solar velocity of about 78 AU/yr. This motion causes relatively nearby extragalactic objects to appear to move compared to more distant objects, an effect that can be measured in the proper motions of nearby galaxies. An object at 1 Mpc and perpendicular to the CMB apex will exhibit a secular parallax, observed as a proper motion, of 78 µas/yr. The relatively large peculiar motions of galaxies make the detection of secular parallax challenging for individual objects. Instead, a statistical parallax measurement can be made for a sample of objects with proper motions, where the global parallax signal is modeled as an E-mode dipole that diminishes linearly with distance. We present preliminary results of applying this model to a sample of nearby galaxies with Gaia proper motions to detect the statistical secular parallax signal. The statistical measurement can be used to calibrate the canonical cosmological “distance ladder.”

  18. Comparison of the accuracy of cone beam computed tomography and medical computed tomography: implications for clinical diagnostics with guided surgery.

    PubMed

    Abboud, Marcus; Calvo-Guirado, Jose Luis; Orentlicher, Gary; Wahl, Gerhard

    2013-01-01

    This study compared the accuracy of cone beam computed tomography (CBCT) and medical-grade CT in the context of evaluating the diagnostic value and accuracy of fiducial marker localization for reference marker-based guided surgery systems. Cadaver mandibles with attached radiopaque gutta-percha markers, as well as glass balls and composite cylinders of known dimensions, were measured manually with a highly accurate digital caliper. The objects were then scanned using a medical-grade CT scanner (Philips Brilliance 64) and five different CBCT scanners (Sirona Galileos, Morita 3D Accuitomo 80, Vatech PaX-Reve3D, 3M Imtech Iluma, and Planmeca ProMax 3D). The data were then imported into commercially available software, and measurements were made of the scanned markers and objects. CT and CBCT measurements were compared to each other and to the caliper measurements. The difference between the CBCT measurements and the caliper measurements was larger than the difference between the CT measurements and the caliper measurements. Measurements of the cadaver mandible and the geometric reference markers were highly accurate with CT. The average absolute errors of the human mandible measurements were 0.03 mm for CT and 0.23 mm for CBCT. The measurement errors of the geometric objects based on CT ranged between 0.00 and 0.12 mm, compared to an error range between 0.00 and 2.17 mm with the CBCT scanners. CT provided the most accurate images in this study, closely followed by one CBCT of the five tested. Although there were differences in the distance measurements of the hard tissue of the human mandible between CT and CBCT, these differences may not be of clinical significance for most diagnostic purposes. The fiducial marker localization error caused by some CBCT scanners may be a problem for guided surgery systems.

  19. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    PubMed

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  20. Validity of questionnaire self-reports on computer, mouse and keyboard usage during a four-week period.

    PubMed

    Mikkelsen, Sigurd; Vilstrup, Imogen; Lassen, Christina Funch; Kryger, Ann Isabel; Thomsen, Jane Frølund; Andersen, Johan Hviid

    2007-08-01

    To examine the validity and potential biases in self-reports of computer, mouse and keyboard usage times, compared with objective recordings. A study population of 1211 people was asked in a questionnaire to estimate the average time they had worked with computer, mouse and keyboard during the past four working weeks. During the same period, a software program recorded these activities objectively. The study was part of a one-year follow-up study from 2000-1 of musculoskeletal outcomes among Danish computer workers. Self-reports on computer, mouse and keyboard usage times were positively associated with objectively measured activity, but the validity was low. Self-reports explained only between a quarter and a third of the variance of objectively measured activity, and were even lower for one measure (keyboard time). Self-reports overestimated usage times. Overestimation was large at low levels and declined with increasing levels of objectively measured activity. Mouse usage time proportion was an exception with a near 1:1 relation. Variability in objectively measured activity, arm pain, gender and age influenced self-reports in a systematic way, but the effects were modest and sometimes in different directions. Self-reported durations of computer activities are positively associated with objective measures but they are quite inaccurate. Studies using self-reports to establish relations between computer work times and musculoskeletal pain could be biased and lead to falsely increased or decreased risk estimates.

  1. Advancing X-ray scattering metrology using inverse genetic algorithms.

    PubMed

    Hannon, Adam F; Sunday, Daniel F; Windover, Donald; Kline, R Joseph

    2016-01-01

    We compare the speed and effectiveness of two genetic optimization algorithms to the results of statistical sampling via a Markov chain Monte Carlo algorithm to find which is the most robust method for determining real space structure in periodic gratings measured using critical dimension small angle X-ray scattering. Both a covariance matrix adaptation evolutionary strategy and differential evolution algorithm are implemented and compared using various objective functions. The algorithms and objective functions are used to minimize differences between diffraction simulations and measured diffraction data. These simulations are parameterized with an electron density model known to roughly correspond to the real space structure of our nanogratings. The study shows that for X-ray scattering data, the covariance matrix adaptation coupled with a mean-absolute error log objective function is the most efficient combination of algorithm and goodness of fit criterion for finding structures with little foreknowledge about the underlying fine scale structure features of the nanograting.

  2. Comparison of Blood Loss in Laser Lipolysis vs Traditional Liposuction.

    PubMed

    Abdelaal, Mohammed Mahmoud; Aboelatta, Yasser Abdallah

    2014-08-01

    Laser-assisted liposuction has been associated with reduced blood loss. However, this clinical finding has not been evaluated objectively. In this study, the authors objectively estimated the blood loss volume associated with laser lipolysis vs traditional liposuction in various anatomic regions. In this prospective study, 56 patients underwent equal amounts of traditional and laser-assisted liposuction at 2 contralateral anatomic sites. Blood loss volumes were calculated from the lipoaspirates by measuring hemoglobin and red blood cell content. The data were analyzed statistically with repeated-measures analysis of variance and the Mann-Whitney U test. Laser lipolysis can reduce blood loss by more than 50% compared with traditional liposuction. Laser lipolysis resulted in significant reductions in mean blood loss volumes in the abdomen, flanks, back, and breast. The authors provide objective evidence that laser lipolysis significantly reduces blood loss compared with traditional liposuction. 3. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  3. Is there a correlation of sonographic measurements of true vocal cords with gender or body mass indices in normal healthy volunteers?

    PubMed Central

    Bright, Leah; Secko, Michael; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard

    2014-01-01

    Background: Ultrasound is a readily available, non-invasive technique to visualize airway dimensions at the patient's bedside and possibly predict difficult airways before invasively looking; however, it has rarely been used for emergency investigation of the larynx. There is limited literature on the sonographic measurements of true vocal cords in adults and normal parameters must be established before abnormal parameters can be accurately identified. Objectives: The primary objective of the following study is to identify the normal sonographic values of human true vocal cords in an adult population. A secondary objective is to determine if there is a difference in true vocal cord measurements in people with different body mass indices (BMIs). The third objective was to determine if there was a statistical difference in the measurements for both genders. Materials and Methods: True vocal cord measurements were obtained in healthy volunteers by ultrasound fellowship trained emergency medicine physicians using a high frequency linear transducer orientated transversely across the anterior surface of the neck at the level of the thyroid cartilage. The width of the true vocal cord was measured perpendicularly to the length of the cord at its mid-portion. This method was duplicated from a previous study to create a standard of measurement acquisition. Results: A total of 38 subjects were enrolled. The study demonstrated no correlation between vocal cord measurements and patient's characteristics of height, weight, or BMI's. When accounting for vocal cord measurements by gender, males had larger BMI's and larger vocal cord measurements compared with females subjects with a statistically significant different in right vocal cord measurements for females compared with male subjects. Conclusion: No correlation was seen between vocal cord measurements and person's BMIs. In the study group of normal volunteers, there was a difference in size between the male and female vocal cord size. PMID:24812456

  4. Painting recognition with smartphones equipped with inertial measurement unit

    NASA Astrophysics Data System (ADS)

    Masiero, Andrea; Guarnieri, Alberto; Pirotti, Francesco; Vettore, Antonio

    2015-06-01

    Recently, several works have been proposed in the literature to take advantage of the diffusion of smartphones to improve people experience during museum visits. The rationale is that of substituting traditional written/audio guides with interactive electronic guides usable on a mobile phone. Augmented reality systems are usually considered to make the use of such electronic guides more effective for the user. The main goal of such augmented reality system (i.e. providing the user with the information of his/her interest) is usually achieved by properly executing the following three tasks: recognizing the object of interest to the user, retrieving the most relevant information about it, properly presenting the retrieved information. This paper focuses on the first task: we consider the problem of painting recognition by means of measure- ments provided by a smartphone. We assume that the user acquires one image of the painting of interest with the standard camera of the device. This image is compared with a set of reference images of the museum objects in order to recognize the object of interest to the user. Since comparing images taken in different conditions can lead to unsatisfactory recognition results, the acquired image is typically properly transformed in order to improve the results of the recognition system: first, the system estimates the homography between properly matched features in the two images. Then, the user image is transformed accordingly to the estimated homography. Finally, it is compared with the reference one. This work proposes a novel method to exploit inertial measurement unit (IMU) measurements to improve the system performance, in particular in terms of computational load reduction: IMU measurements are exploited to reduce both the computational burden required to estimate the transformation to be applied to the user image, and the number of reference images to be compared with it.

  5. Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration.

    PubMed

    Chen, Lei; Kim, Yunie; Santucci, Karen A

    2007-10-01

    Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.

  6. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor.

    PubMed

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L; Minassian, Arpi

    2016-06-30

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. A Comparative Analysis of Results Using Three Leadership Style Measurement Instruments.

    DTIC Science & Technology

    The objective of this research was to determine if there was conceptual similarity among leadership styles as measured by the results of the Ohio...hybrid statistic was developed here to measure the degree of association among the leadership styles recorded by each individual respondent. The

  8. Using passive capillary lysimeter water flux measurements to improve flow predictions in variably saturated soils.

    USDA-ARS?s Scientific Manuscript database

    Passive capillary lysimeters (PCLs) are uniquely suited for measuring water fluxes in variably-saturated soils. The objective of this work was to compare PCL flux measurements with simulated fluxes obtained with a calibrated unsaturated flow model. The Richards equation-based model was calibrated us...

  9. Detection Technique for Artificially Illuminated Objects in the Outer Solar System and Beyond

    PubMed Central

    Loeb, Abraham

    2012-01-01

    Abstract Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10−3. Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=−4, whereas artificially illuminated objects should exhibit α=−2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=−2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars. Key Words: Astrobiology—SETI—Kuiper belt objects—Artificial illumination. Astrobiology 12, 290–294. PMID:22490065

  10. Real-time reliability measure-driven multi-hypothesis tracking using 2D and 3D features

    NASA Astrophysics Data System (ADS)

    Zúñiga, Marcos D.; Brémond, François; Thonnat, Monique

    2011-12-01

    We propose a new multi-target tracking approach, which is able to reliably track multiple objects even with poor segmentation results due to noisy environments. The approach takes advantage of a new dual object model combining 2D and 3D features through reliability measures. In order to obtain these 3D features, a new classifier associates an object class label to each moving region (e.g. person, vehicle), a parallelepiped model and visual reliability measures of its attributes. These reliability measures allow to properly weight the contribution of noisy, erroneous or false data in order to better maintain the integrity of the object dynamics model. Then, a new multi-target tracking algorithm uses these object descriptions to generate tracking hypotheses about the objects moving in the scene. This tracking approach is able to manage many-to-many visual target correspondences. For achieving this characteristic, the algorithm takes advantage of 3D models for merging dissociated visual evidence (moving regions) potentially corresponding to the same real object, according to previously obtained information. The tracking approach has been validated using video surveillance benchmarks publicly accessible. The obtained performance is real time and the results are competitive compared with other tracking algorithms, with minimal (or null) reconfiguration effort between different videos.

  11. Panoramic Images Mapping Tools Integrated Within the ESRI ArcGIS Software

    NASA Astrophysics Data System (ADS)

    Guo, Jiao; Zhong, Ruofei; Zeng, Fanyang

    2014-03-01

    There is a general study on panoramic images which are presented along with appearance of the Google street map. Despite 360 degree viewing of street, we can realize more applications over panoramic images. This paper developed a toolkits plugged in ArcGIS, which can view panoramic photographs at street level directly from ArcMap and measure and capture all visible elements as frontages, trees and bridges. We use a series of panoramic images adjoined with absolute coordinate through GPS and IMU. There are two methods in this paper to measure object from these panoramic images: one is to intersect object position through a stereogram; the other one is multichip matching involved more than three images which all cover the object. While someone wants to measure objects from these panoramic images, each two panoramic images which both contain the object can be chosen to display on ArcMap. Then we calculate correlation coefficient of the two chosen panoramic images so as to calculate the coordinate of object. Our study test different patterns of panoramic pairs and compare the results of measurement to the real value of objects so as to offer the best choosing suggestion. The article has mainly elaborated the principles of calculating correlation coefficient and multichip matching.

  12. The associations between objectively-determined and self-reported urban form characteristics and neighborhood-based walking in adults.

    PubMed

    Jack, Elizabeth; McCormack, Gavin R

    2014-06-04

    Self-reported and objectively-determined neighborhood built characteristics are associated with physical activity, yet little is known about their combined influence on walking. This study: 1) compared self-reported measures of the neighborhood built environment between objectively-determined low, medium, and high walkable neighborhoods; 2) estimated the relative associations between self-reported and objectively-determined neighborhood characteristics and walking and; 3) examined the extent to which the objectively-determined built environment moderates the association between self-reported measures of the neighborhood built environment and walking. A random cross-section of 1875 Canadian adults completed a telephone-interview and postal questionnaire capturing neighborhood walkability, neighborhood-based walking, socio-demographic characteristics, walking attitudes, and residential self-selection. Walkability of each respondent's neighborhood was objectively-determined (low [LW], medium [MW], and high walkable [HW]). Covariate-adjusted regression models estimated the associations between weekly participation and duration in transportation and recreational walking and self-reported and objectively-determined walkability. Compared with objectively-determined LW neighborhoods, respondents in HW neighborhoods positively perceived access to services, street connectivity, pedestrian infrastructure, and utilitarian and recreation destination mix, but negatively perceived motor vehicle traffic and crime related safety. Compared with residents of objectively-determined LW neighborhoods, residents of HW neighborhoods were more likely (p < .05) to participate in (odds ratio [OR] = 3.06), and spend more time, per week (193 min/wk) transportation walking. Perceived access to services, street connectivity, motor vehicle safety, and mix of recreational destinations were also significantly associated with transportation walking. With regard to interactions, HW x utilitarian destination mix was positively associated with participation, HW x physical barriers and MW x pedestrian infrastructure were positively associated with minutes, and HW x safety from crime was negatively associated with minutes, of transportation walking. Neither neighborhood type nor its interactions with perceived measures of walkability were associated with recreational walking, although perceived aesthetics was associated with participation (OR = 1.18, p < .05). Objectively-determined and self-reported built characteristics are associated with neighborhood-based transportation walking. The objectively-determined built environment might moderate associations between perceptions of walkability and neighborhood-based transportation walking. Interventions that target perceptions in addition to modifications to the neighborhood built environment could result in increases in physical activity among adults.

  13. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects

    NASA Astrophysics Data System (ADS)

    Pantelić, Dejan V.; Grujić, Dušan Ž.; Vasiljević, Darko M.

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  14. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects.

    PubMed

    Pantelić, Dejan V; Grujić, Dušan Ž; Vasiljević, Darko M

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  15. Sleep and Sleepiness among First-Time Postpartum Parents: A Field- and Laboratory-Based Multimethod Assessment

    PubMed Central

    Insana, Salvatore P.; Montgomery-Downs, Hawley E.

    2012-01-01

    The study aim was to compare sleep, sleepiness, fatigue, and neurobehavioral performance among first-time mothers and fathers during their early postpartum period. Participants were 21 first-time postpartum mother-father dyads (N=42) and seven childless control dyads (N=14). Within their natural environment, participants completed one week of wrist actigraphy monitoring, along with multi-day self-administered sleepiness, fatigue, and neurobehavioral performance measures. The assessment week was followed by an objective laboratory based test of sleepiness. Mothers obtained more sleep compared to fathers, but mothers’ sleep was more disturbed by awakenings. Fathers had greater objectively measured sleepiness than mothers. Mothers and fathers did not differ on subjectively measured sleep quality, sleepiness, or fatigue; however, mothers had worse neurobehavioral performance than fathers. Compared to control dyads, postpartum parents experienced greater sleep disturbance, sleepiness, and sleepiness associated impairments. Study results inform social policy, postpartum sleep interventions, and research on postpartum family systems and mechanisms that propagate sleepiness. PMID:22553114

  16. Characterization of Orbital Debris Photometric Properties Derived from Laboratory-Based Measurements

    NASA Technical Reports Server (NTRS)

    Cowardin, Heather; Seitzer, Pat; Abercromby, Kira; Barker, Ed; Schildknecht, Thomas

    2010-01-01

    Capitalizing on optical data products and applying them to generate a more complete understanding of orbital space objects, is a key objective of NASA's Optical Measurement Program, and a primary objective for the creation of the Optical Measurements Center(OMC). The OMC attempts to emulate space-based illumination conditions using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The data acquired in the OMC are a function of known shape, size, and material. These three physical parameters are key to understanding the orbital debris environment in more depth. For optical observations, one must rely on spectroscopic or photometric measurements to ascertain an object's material type. Determination of an object s shape using remote observations is more complicated due to the various light scattering properties each object present and is a subject that requires more study. It is much easier to look at the periodicity of the light curve and analyze its structure for rotation. In order to best simulate the orbital debris population, three main sources were used as test fragments for optical measurements: flight-ready materials, destructive hypervelocity testing (simulating on-orbit collisions) and destructive pressure testing (simulating on-orbit explosions). Laboratory optical characteristics of fragments were measured, including light curve shape, phase angle dependence, and photometric and spectroscopic color indices. These characteristics were then compared with similar optical measurements acquired from telescopic observations in order to correlate remote and laboratory properties with the intent of ascertaining the intrinsic properties of the observed orbital debris

  17. Magnetic levitation in the analysis of foods and water.

    PubMed

    Mirica, Katherine A; Phillips, Scott T; Mace, Charles R; Whitesides, George M

    2010-06-09

    This paper describes a method and a sensor that use magnetic levitation (MagLev) to characterize samples of food and water on the basis of measurements of density. The sensor comprises two permanent NdFeB magnets positioned on top of each other in a configuration with like poles facing and a container filled with a solution of paramagnetic ions. Measurements of density are obtained by suspending a diamagnetic object in the container filled with the paramagnetic fluid, placing the container between the magnets, and measuring the vertical position of the suspended object. MagLev was used to estimate the salinity of water, to compare a variety of vegetable oils on the basis of the ratio of polyunsaturated fat to monounsaturated fat, to compare the contents of fat in milk, cheese, and peanut butter, and to determine the density of grains.

  18. Library Objectives and Performance Measures and Their Use in Decision Making

    ERIC Educational Resources Information Center

    Hamburg, Morris; And Others

    1972-01-01

    For optimal allocations of limited funds, it is necessary for libraries to develop measures of output. Various forms of user exposure to documents are discussed in an effort to develop such measures for public libraries. It is suggested that the accrual method of accounting be used to compare such measures with costs. (40 references) (Author/NH)

  19. Empirical Approaches to Measuring the Intelligibility of Different Varieties of English in Predicting Listener Comprehension

    ERIC Educational Resources Information Center

    Kang, Okim; Thomson, Ron I.; Moran, Meghan

    2018-01-01

    This study compared five research-based intelligibility measures as they were applied to six varieties of English. The objective was to determine which approach to measuring intelligibility would be most reliable for predicting listener comprehension, as measured through a listening comprehension test similar to the Test of English as a Foreign…

  20. Meta-Analysis of Treatment Outcomes Measured by the Y-OQ and Y-OQ-SR Comparing Wilderness and Non-Wilderness Treatment Programs

    ERIC Educational Resources Information Center

    Gillis, Harold L.; Speelman, Elizabeth; Linville, Noelle; Bailey, Emily; Kalle, Ashley; Oglesbee, Nathan; Sandlin, James; Thompson, Lauren; Jensen, Jennifer

    2016-01-01

    Background: Monitoring youth treatments requires outcome instruments sensitive to change. The Y-OQ and the Y-OQ-SR measure behavioral change during psychological treatment. Objective: The focus of this study was to compare treatment progress of youth in studies using the Youth Outcome Questionnaire (YOQ) or the Youth Outcome Questionnaire Self…

  1. [Comparison study on subjective and objective measurements of the accommodative convergence to accommodation ratio].

    PubMed

    Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan

    2012-05-01

    To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.

  2. Multi-objective and Perishable Fuzzy Inventory Models Having Weibull Life-time With Time Dependent Demand, Demand Dependent Production and Time Varying Holding Cost: A Possibility/Necessity Approach

    NASA Astrophysics Data System (ADS)

    Pathak, Savita; Mondal, Seema Sarkar

    2010-10-01

    A multi-objective inventory model of deteriorating item has been developed with Weibull rate of decay, time dependent demand, demand dependent production, time varying holding cost allowing shortages in fuzzy environments for non- integrated and integrated businesses. Here objective is to maximize the profit from different deteriorating items with space constraint. The impreciseness of inventory parameters and goals for non-integrated business has been expressed by linear membership functions. The compromised solutions are obtained by different fuzzy optimization methods. To incorporate the relative importance of the objectives, the different cardinal weights crisp/fuzzy have been assigned. The models are illustrated with numerical examples and results of models with crisp/fuzzy weights are compared. The result for the model assuming them to be integrated business is obtained by using Generalized Reduced Gradient Method (GRG). The fuzzy integrated model with imprecise inventory cost is formulated to optimize the possibility necessity measure of fuzzy goal of the objective function by using credibility measure of fuzzy event by taking fuzzy expectation. The results of crisp/fuzzy integrated model are illustrated with numerical examples and results are compared.

  3. Simulating the nasal cycle with computational fluid dynamics

    PubMed Central

    Patel, Ruchin G.; Garcia, Guilherme J. M.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.

    2015-01-01

    Objectives (1) Develop a method to account for the confounding effect of the nasal cycle when comparing pre- and post-surgery objective measures of nasal patency. (2) Illustrate this method by reporting objective measures derived from computational fluid dynamics (CFD) models spanning the full range of mucosal engorgement associated with the nasal cycle in two subjects. Study Design Retrospective Setting Academic tertiary medical center. Subjects and Methods A cohort of 24 nasal airway obstruction patients was reviewed to select the two patients with the greatest reciprocal change in mucosal engorgement between pre- and post-surgery computed tomography (CT) scans. Three-dimensional anatomic models were created based on the pre- and post-operative CT scans. Nasal cycling models were also created by gradually changing the thickness of the inferior turbinate, middle turbinate, and septal swell body. CFD was used to simulate airflow and to calculate nasal resistance and average heat flux. Results Before accounting for the nasal cycle, Patient A appeared to have a paradoxical worsening nasal obstruction in the right cavity postoperatively. After accounting for the nasal cycle, Patient A had small improvements in objective measures postoperatively. The magnitude of the surgical effect also differed in Patient B after accounting for the nasal cycle. Conclusion By simulating the nasal cycle and comparing models in similar congestive states, surgical changes in nasal patency can be distinguished from physiological changes associated with the nasal cycle. This ability can lead to more precise comparisons of pre and post-surgery objective measures and potentially more accurate virtual surgery planning. PMID:25450411

  4. Objectively measured physical activity in obese women with and without migraine.

    PubMed

    Bond, Dale S; Thomas, J Graham; O'Leary, Kevin C; Lipton, Richard B; Peterlin, B Lee; Roth, Julie; Rathier, Lucille; Wing, Rena R

    2015-09-01

    The aim of this article is to cross-sectionally compare objectively measured physical activity (PA) levels and their association with migraine characteristics in obese women with and without migraine. Obese women seeking weight loss treatment were divided into migraine (n = 25) and control (n = 25) groups matched by age and body mass index (BMI). Participants wore the SenseWear Armband monitor for seven days to objectively evaluate daily light-(LPA) and moderate-to-vigorous intensity PA (MVPA). Migraine diagnosis was confirmed by a neurologist using ICHD-3-beta criteria. Migraine characteristics were tracked daily using a smartphone-based diary over a four-week period immediately preceding the objective PA assessment. Migraine participants spent 57.9 fewer minutes/day in LPA (141.1 ± 56.4 vs. 199.1 ± 87.7, p = 0.019) and 24.5 fewer minutes/day in MVPA (27.8 ± 17.0 vs. 52.3 ± 26.0, p < 0.001), compared to controls. Migraine participants reported 4.8 ± 3.1 migraine days/month (mean duration = 17.1 ± 8.9 hours; mean maximum pain severity = 6.4 ± 1.7 on a 0-10 scale). Higher BMI (p < 0.05), but not migraine characteristics, were related to lower total PA. Additionally, total objectively measured PA was not associated with how often PA was reported to exacerbate migraine attacks during the four-week diary assessment. Obese women with migraine spent nearly 1.5 hours/day less in PA compared to controls; however, lower PA was not related to migraine characteristics. Further research is needed to identify PA barriers and effective interventions in obese women with migraine. © International Headache Society 2014.

  5. Cognitive Assessment Interview (CAI): Validity as a co-primary measure of cognition across phases of schizophrenia.

    PubMed

    Ventura, Joseph; Subotnik, Kenneth L; Ered, Arielle; Hellemann, Gerhard S; Nuechterlein, Keith H

    2016-04-01

    Progress has been made in developing interview-based measures for the assessment of cognitive functioning, such as the Cognitive Assessment Interview (CAI), as co-primary measures that compliment objective neurocognitive assessments and daily functioning. However, a few questions remain, including whether the relationships with objective cognitive measures and daily functioning are high enough to justify the CAI as an co-primary measure and whether patient-only assessments are valid. Participants were first-episode schizophrenia patients (n=60) and demographically-similar healthy controls (n=35), chronic schizophrenia patients (n=38) and demographically similar healthy controls (n=19). Participants were assessed at baseline with an interview-based measure of cognitive functioning (CAI), a test of objective cognitive functioning, functional capacity, and role functioning at baseline, and in the first episode patients again 6 months later (n=28). CAI ratings were correlated with objective cognitive functioning, functional capacity, and functional outcomes in first-episode schizophrenia patients at similar magnitudes as in chronic patients. Comparisons of first-episode and chronic patients with healthy controls indicated that the CAI sensitively detected deficits in schizophrenia. The relationship of CAI Patient-Only ratings with objective cognitive functioning, functional capacity, and daily functioning were comparable to CAI Rater scores that included informant information. These results confirm in an independent sample the relationship of the CAI ratings with objectively measured cognition, functional capacity, and role functioning. Comparison of schizophrenia patients with healthy controls further validates the CAI as an co-primary measure of cognitive deficits. Also, CAI change scores were strongly related to objective cognitive change indicating sensitivity to change. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Physical functioning in patients with ankylosing spondylitis: comparing approaches of experienced ability with self-reported and objectively measured physical activity.

    PubMed

    van Genderen, Simon; van den Borne, Carlie; Geusens, Piet; van der Linden, Sjef; Boonen, Annelies; Plasqui, Guy

    2014-04-01

    Physical functioning can be assessed by different approaches that are characterized by increasing levels of individual appraisal. There is insufficient insight into which approach is the most informative in patients with ankylosing spondylitis (AS) compared with control subjects. The objective of this study was to compare patients with AS and control subjects regarding 3 approaches of functioning: experienced ability to perform activities (Bath Ankylosing Spondylitis Functional Index [BASFI]), self-reported amount of physical activity (PA) (Baecke questionnaire), and the objectively measured amount of PA (triaxial accelerometer). This case-control study included 24 AS patients and 24 control subjects (matched for age, gender, and body mass index). Subjects completed the BASFI and Baecke questionnaire and wore a triaxial accelerometer. Subjects also completed other self-reported measures on disease activity (Bath AS Disease Activity Index), fatigue (Multidimensional Fatigue Inventory), and overall health (EuroQol visual analog scale). Both groups included 14 men (58%), and the mean age was 48 years. Patients scored significantly worse on the BASFI (3.9 vs 0.2) than their healthy peers, whereas PA assessed by Baecke and the accelerometer did not differ between groups. Correlations between approaches of physical functioning were low to moderate. Bath Ankylosing Spondylitis Functional Index was associated with disease activity (r = 0.49) and physical fatigue (0.73) and Baecke with physical and activity related fatigue (r = 0.54 and r = 0.54), but total PA assessed by accelerometer was not associated with any of these experience-based health outcomes. Different approaches of the concept physical functioning in patients with AS provide different information. Compared with matched control subjects, patients with AS report more difficulties but report and objectively perform the same amount of PA.

  7. The better way to determine the validity, reliability, objectivity and accuracy of measuring devices.

    PubMed

    Pazira, Parvin; Rostami Haji-Abadi, Mahdi; Zolaktaf, Vahid; Sabahi, Mohammadfarzan; Pazira, Toomaj

    2016-06-08

    In relation to statistical analysis, studies to determine the validity, reliability, objectivity and precision of new measuring devices are usually incomplete, due in part to using only correlation coefficient and ignoring the data dispersion. The aim of this study was to demonstrate the best way to determine the validity, reliability, objectivity and accuracy of an electro-inclinometer or other measuring devices. Another purpose of this study is to answer the question of whether reliability and objectivity represent accuracy of measuring devices. The validity of an electro-inclinometer was examined by mechanical and geometric methods. The objectivity and reliability of the device was assessed by calculating Cronbach's alpha for repeated measurements by three raters and by measurements on the same person by mechanical goniometer and the electro-inclinometer. Measurements were performed on "hip flexion with the extended knee" and "shoulder abduction with the extended elbow." The raters measured every angle three times within an interval of two hours. The three-way ANOVA was used to determine accuracy. The results of mechanical and geometric analysis showed that validity of the electro-inclinometer was 1.00 and level of error was less than one degree. Objectivity and reliability of electro-inclinometer was 0.999, while objectivity of mechanical goniometer was in the range of 0.802 to 0.966 and the reliability was 0.760 to 0.961. For hip flexion, the difference between raters in joints angle measurement by electro-inclinometer and mechanical goniometer was 1.74 and 16.33 degree (P<0.05), respectively. The differences for shoulder abduction measurement by electro-inclinometer and goniometer were 0.35 and 4.40 degree (P<0.05). Although both the objectivity and reliability are acceptable, the results showed that measurement error was very high in the mechanical goniometer. Therefore, it can be concluded that objectivity and reliability alone cannot determine the accuracy of a device and it is preferable to use other statistical methods to compare and evaluate the accuracy of these two devices.

  8. The discrepancy between subjective and objective measures of sleep in older adults receiving CBT for comorbid insomnia.

    PubMed

    Lund, Hannah G; Rybarczyk, Bruce D; Perrin, Paul B; Leszczyszyn, David; Stepanski, Edward

    2013-10-01

    To examine the effect of cognitive-behavioral therapy for insomnia (CBT-I) on the underreporting of sleep relative to objective measurement, a common occurrence among individuals with insomnia. Pre-treatment and post-treatment self-report measures of sleep were compared with those obtained from home-based polysomnography (PSG) in 60 adults (mean age = 69.17; 42 women) with comorbid insomnia. The self-report data were published previously in a randomized controlled trial demonstrating the efficacy of CBT-I compared with a placebo treatment. Self-report measures significantly underestimated sleep at pre-treatment and CBT-I led to a correction in this discrepancy. There were no significant changes in PSG after CBT-I. Path analysis showed that an increase in an objective proxy measure of sleep quality (i.e., decreased stage N1 sleep) after CBT-I was significantly related to improvements in self-report of sleep, with full mediation by reductions in discrepancy. This is the first CBT-I outcome study to analyze discrepancy changes and demonstrate that these changes account for a significant portion of self-report outcome. In addition, improved sleep quality as measured by a decrease in percentage of stage N1 sleep following treatment may be one mechanism that explains why sleep estimation is more accurate following CBT-I. © 2012 Wiley Periodicals, Inc.

  9. Applying graph partitioning methods in measurement-based dynamic load balancing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatele, Abhinav; Fourestier, Sebastien; Menon, Harshitha

    Load imbalance leads to an increasing waste of resources as an application is scaled to more and more processors. Achieving the best parallel efficiency for a program requires optimal load balancing which is a NP-hard problem. However, finding near-optimal solutions to this problem for complex computational science and engineering applications is becoming increasingly important. Charm++, a migratable objects based programming model, provides a measurement-based dynamic load balancing framework. This framework instruments and then migrates over-decomposed objects to balance computational load and communication at runtime. This paper explores the use of graph partitioning algorithms, traditionally used for partitioning physical domains/meshes, formore » measurement-based dynamic load balancing of parallel applications. In particular, we present repartitioning methods developed in a graph partitioning toolbox called SCOTCH that consider the previous mapping to minimize migration costs. We also discuss a new imbalance reduction algorithm for graphs with irregular load distributions. We compare several load balancing algorithms using microbenchmarks on Intrepid and Ranger and evaluate the effect of communication, number of cores and number of objects on the benefit achieved from load balancing. New algorithms developed in SCOTCH lead to better performance compared to the METIS partitioners for several cases, both in terms of the application execution time and fewer number of objects migrated.« less

  10. Early Adverse Experience Increases Emotional Reactivity in Juvenile Rhesus Macaques: Relation to Amygdala Volume

    PubMed Central

    Howell, B.R.; Grand, A. P.; McCormack, K. M.; Shi, Y.; LaPrarie, J.; Maestripieri, D.; Styner, M. A.; Sanchez, M. M.

    2015-01-01

    This study investigated the impact of infant maltreatment on juvenile rhesus monkeys’ behavioral reactivity to novel stimuli and its associations with amygdala volume. Behavioral reactivity to novel stimuli of varying threat intensity was measured using Approach/Avoidance (AA) and Human Intruder (HI) tasks. In vivo magnetic resonance imaging (MRI) was used to measure amygdala volume. Interestingly, group behavioral differences were context-dependent. When exposed to a human intruder, maltreated subjects displayed more anxious behaviors than controls; however, when presented with fear-evoking objects, maltreated animals exhibited increased aggression and a shorter latency to inspect the objects. Finally, under testing conditions with the lowest levels of threat (neutral novel objects) maltreated animals also showed shorter latencies to inspect objects, and reduced avoidance and increased exploration compared to controls. This suggests alterations in threat assessment and less behavioral inhibition in animals with early adverse experience compared to controls. Some of these behavioral responses were associated with amygdala volume, which was positively correlated with abuse rates received during infancy, particularly reflecting a relationship with exploration, consistent with previous studies. PMID:25196846

  11. Effect of space exposure of some epoxy matrix composites on their thermal expansion and mechanical properties (A0138-8)

    NASA Technical Reports Server (NTRS)

    Elberg, R.

    1984-01-01

    This experiment has three objectives. The first and main objective is to detect a possible variation in the coefficient of thermal expansion of composite samples during a 1-year exposure to the near-Earth orbital environment. A second objective is to detect a possible change in the mechanical integrity of composite products, both simple elements and honeycomb sandwich assemblies. A third objective is to compare the behavior of two epoxy resins commonly used in space structural production. The experimental approach is to passively expose samples of epoxy matrix composite materials to the space environment and to compare preflight and postflight measurements of mechanical properties. The experiment will be located in one of the three FRECOPA (French cooperative payload) boxes in a 12-in.-deep peripheral tray that contains nine other experiments from France. The FRECOPA box will protect the samples from contamination during the launch and reentry phases of the mission. The coefficients of thermal expansion are measured on Earth before and after space exposure.

  12. Metamemory function in chemotherapy-treated patients with breast cancer: an explanation for the dissociation between subjective and objective memory measures?

    PubMed

    Collins, Barbara; Paquet, Lise; Dominelli, Rachelle; White, Amanda; MacKenzie, Joyce

    2017-01-01

    The purpose of this study was to determine if a deficit in metamemory could account for the disparity between subjective and objective measures of memory function commonly observed in patients with breast cancer (BC). Metamemory refers to the awareness and management of one's own memory function. It is considered an aspect of executive functioning, one of the most common areas of cognitive compromise associated with BC and its treatment. Fifty-four women with early stage BC who had recently completed chemotherapy were compared with 54 healthy women matched on age and education. Cognitive function was objectively assessed with a neuropsychological test battery and subjectively assessed with the Functional Assessment of Cancer Therapy Cognitive Scale. Metamemory was assessed with a Feeling of Knowing (FOK) paradigm. The patients with BC scored significantly lower than the controls on both the objective and subjective cognitive measures, as well as on free recall and recognition conditions of the FOK, suggesting some decline in primary memory functions such as working memory, encoding, and retrieval. The discrepancy between the objective and subjective measures was larger in the patients with BC than in the controls, but there was no difference between the groups on the FOK metamemory index. Discrepancy in objective and subjective measures of cognition in patients with BC cannot be accounted for in terms of a deficit in meta-cognition. Objective and subjective measures are complementary, and a comprehensive cognitive assessment in patients with BC requires both. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Evaluation and comparison of current fetal ultrasound image segmentation methods for biometric measurements: a grand challenge.

    PubMed

    Rueda, Sylvia; Fathima, Sana; Knight, Caroline L; Yaqub, Mohammad; Papageorghiou, Aris T; Rahmatullah, Bahbibi; Foi, Alessandro; Maggioni, Matteo; Pepe, Antonietta; Tohka, Jussi; Stebbing, Richard V; McManigle, John E; Ciurte, Anca; Bresson, Xavier; Cuadra, Meritxell Bach; Sun, Changming; Ponomarev, Gennady V; Gelfand, Mikhail S; Kazanov, Marat D; Wang, Ching-Wei; Chen, Hsiang-Chou; Peng, Chun-Wei; Hung, Chu-Mei; Noble, J Alison

    2014-04-01

    This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

  14. A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS).

    PubMed

    Guo, Junfeng; Wang, Chao; Chan, Kung-Sik; Jin, Dakai; Saha, Punam K; Sieren, Jered P; Barr, R G; Han, MeiLan K; Kazerooni, Ella; Cooper, Christopher B; Couper, David; Newell, John D; Hoffman, Eric A

    2016-05-01

    A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dual source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [-6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors' results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.

  15. A controlled statistical study to assess measurement variability as a function of test object position and configuration for automated surveillance in a multicenter longitudinal COPD study (SPIROMICS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Junfeng; Newell, John D.; Wang, Chao

    Purpose: A test object (phantom) is an important tool to evaluate comparability and stability of CT scanners used in multicenter and longitudinal studies. However, there are many sources of error that can interfere with the test object-derived quantitative measurements. Here the authors investigated three major possible sources of operator error in the use of a test object employed to assess pulmonary density-related as well as airway-related metrics. Methods: Two kinds of experiments were carried out to assess measurement variability caused by imperfect scanning status. The first one consisted of three experiments. A COPDGene test object was scanned using a dualmore » source multidetector computed tomographic scanner (Siemens Somatom Flash) with the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS) inspiration protocol (120 kV, 110 mAs, pitch = 1, slice thickness = 0.75 mm, slice spacing = 0.5 mm) to evaluate the effects of tilt angle, water bottle offset, and air bubble size. After analysis of these results, a guideline was reached in order to achieve more reliable results for this test object. Next the authors applied the above findings to 2272 test object scans collected over 4 years as part of the SPIROMICS study. The authors compared changes of the data consistency before and after excluding the scans that failed to pass the guideline. Results: This study established the following limits for the test object: tilt index ≤0.3, water bottle offset limits of [−6.6 mm, 7.4 mm], and no air bubble within the water bottle, where tilt index is a measure incorporating two tilt angles around x- and y-axis. With 95% confidence, the density measurement variation for all five interested materials in the test object (acrylic, water, lung, inside air, and outside air) resulting from all three error sources can be limited to ±0.9 HU (summed in quadrature), when all the requirements are satisfied. The authors applied these criteria to 2272 SPIROMICS scans and demonstrated a significant reduction in measurement variation associated with the test object. Conclusions: Three operator errors were identified which significantly affected the usability of the acquired scan images of the test object used for monitoring scanner stability in a multicenter study. The authors’ results demonstrated that at the time of test object scan receipt at a radiology core laboratory, quality control procedures should include an assessment of tilt index, water bottle offset, and air bubble size within the water bottle. Application of this methodology to 2272 SPIROMICS scans indicated that their findings were not limited to the scanner make and model used for the initial test but was generalizable to both Siemens and GE scanners which comprise the scanner types used within the SPIROMICS study.« less

  16. Metrology test object for dimensional verification in additive manufacturing of metals for biomedical applications.

    PubMed

    Teeter, Matthew G; Kopacz, Alexander J; Nikolov, Hristo N; Holdsworth, David W

    2015-01-01

    Additive manufacturing continues to increase in popularity and is being used in applications such as biomaterial ingrowth that requires sub-millimeter dimensional accuracy. The purpose of this study was to design a metrology test object for determining the capabilities of additive manufacturing systems to produce common objects, with a focus on those relevant to medical applications. The test object was designed with a variety of features of varying dimensions, including holes, cylinders, rectangles, gaps, and lattices. The object was built using selective laser melting, and the produced dimensions were compared to the target dimensions. Location of the test objects on the build plate did not affect dimensions. Features with dimensions less than 0.300 mm did not build or were overbuilt to a minimum of 0.300 mm. The mean difference between target and measured dimensions was less than 0.100 mm in all cases. The test object is applicable to multiple systems and materials, tests the effect of location on the build, uses a minimum of material, and can be measured with a variety of efficient metrology tools (including measuring microscopes and micro-CT). Investigators can use this test object to determine the limits of systems and adjust build parameters to achieve maximum accuracy. © IMechE 2014.

  17. Appropriate Objective Functions for Quantifying Iris Mechanical Properties Using Inverse Finite Element Modeling.

    PubMed

    Pant, Anup D; Dorairaj, Syril K; Amini, Rouzbeh

    2018-07-01

    Quantifying the mechanical properties of the iris is important, as it provides insight into the pathophysiology of glaucoma. Recent ex vivo studies have shown that the mechanical properties of the iris are different in glaucomatous eyes as compared to normal ones. Notwithstanding the importance of the ex vivo studies, such measurements are severely limited for diagnosis and preclude development of treatment strategies. With the advent of detailed imaging modalities, it is possible to determine the in vivo mechanical properties using inverse finite element (FE) modeling. An inverse modeling approach requires an appropriate objective function for reliable estimation of parameters. In the case of the iris, numerous measurements such as iris chord length (CL) and iris concavity (CV) are made routinely in clinical practice. In this study, we have evaluated five different objective functions chosen based on the iris biometrics (in the presence and absence of clinical measurement errors) to determine the appropriate criterion for inverse modeling. Our results showed that in the absence of experimental measurement error, a combination of iris CL and CV can be used as the objective function. However, with the addition of measurement errors, the objective functions that employ a large number of local displacement values provide more reliable outcomes.

  18. From bead to rod: Comparison of theories by measuring translational drag coefficients of micron-sized magnetic bead-chains in Stokes flow

    PubMed Central

    Lu, Chen; Zhao, Xiaodan; Kawamura, Ryo

    2017-01-01

    Frictional drag force on an object in Stokes flow follows a linear relationship with the velocity of translation and a translational drag coefficient. This drag coefficient is related to the size, shape, and orientation of the object. For rod-like objects, analytical solutions of the drag coefficients have been proposed based on three rough approximations of the rod geometry, namely the bead model, ellipsoid model, and cylinder model. These theories all agree that translational drag coefficients of rod-like objects are functions of the rod length and aspect ratio, but differ among one another on the correction factor terms in the equations. By tracking the displacement of the particles through stationary fluids of calibrated viscosity in magnetic tweezers setup, we experimentally measured the drag coefficients of micron-sized beads and their bead-chain formations with chain length of 2 to 27. We verified our methodology with analytical solutions of dimers of two touching beads, and compared our measured drag coefficient values of rod-like objects with theoretical calculations. Our comparison reveals several analytical solutions that used more appropriate approximation and derived formulae that agree with our measurement better. PMID:29145447

  19. Measuring the circular motion of small objects using laser stroboscopic images.

    PubMed

    Wang, Hairong; Fu, Y; Du, R

    2008-01-01

    Measuring the circular motion of a small object, including its displacement, speed, and acceleration, is a challenging task. This paper presents a new method for measuring repetitive and/or nonrepetitive, constant speed and/or variable speed circular motion using laser stroboscopic images. Under stroboscopic illumination, each image taken by an ordinary camera records multioutlines of an object in motion; hence, processing the stroboscopic image will be able to extract the motion information. We built an experiment apparatus consisting of a laser as the light source, a stereomicroscope to magnify the image, and a normal complementary metal oxide semiconductor camera to record the image. As the object is in motion, the stroboscopic illumination generates a speckle pattern on the object that can be recorded by the camera and analyzed by a computer. Experimental results indicate that the stroboscopic imaging is stable under various conditions. Moreover, the characteristics of the motion, including the displacement, the velocity, and the acceleration can be calculated based on the width of speckle marks, the illumination intensity, the duty cycle, and the sampling frequency. Compared with the popular high-speed camera method, the presented method may achieve the same measuring accuracy, but with much reduced cost and complexity.

  20. Application of an optical interferometer for measuring the surface contour of micro-components

    NASA Astrophysics Data System (ADS)

    Wang, S. H.; Tay, C. J.

    2006-04-01

    The application of an optical interferometric system using a Mireau objective to measure the surface profile of micro-components is described. The proposed system produces a uniform monochromatic illumination over the test area and introduces an interference fringe pattern localized near the test surface. Both the interference fringes and the 2D image of the test surface can be focused by an infinity microscope system consisting of a Mireau objective and a tube lens. A piezoelectric transducer (PZT) attached to the Mireau objective can move precisely along the optical axis of the objective. This enables the implementation of phase-shifting interferometry without changing the focus of a CCD sensor as the combination of the Mireau objective and the tube lens provides a depth of focus which is deep in comparison to the phase-shifting step. Experimental results from surface profilometry of the protrusion/undercut of a polished fibre within an optical connector and of the curved surface of a micromirror demonstrate that features in the order of nanometres are measurable. Measurements on standard blocks also show that the accuracy of the proposed system is comparable to an existing commercial white-light interferometer and a stylus profilometer.

  1. Effects of automobile steering characteristics on driver vehicle system dynamics in regulation tasks

    NASA Technical Reports Server (NTRS)

    Mcruer, D. T.; Klein, R.

    1975-01-01

    A regulation task which subjected the automobile to a random gust disturbance which is countered by driver control action is used to study the effects of various automobile steering characteristics on the driver/vehicle system. The experiments used a variable stability automobile specially configured to permit insertion of the simulated gust disturbance and the measurement of the driver/vehicle system characteristics. Driver/vehicle system dynamics were measured and interpreted as an effective open loop system describing function. Objective measures of system bandwidth, stability, and time delays were deduced and compared. These objective measures were supplemented by driver ratings. A tentative optimum range of vehicle dynamics for the directional regulation task was established.

  2. Multipoint vibrometry with dynamic and static holograms.

    PubMed

    Haist, T; Lingel, C; Osten, W; Winter, M; Giesen, M; Ritter, F; Sandfort, K; Rembe, C; Bendel, K

    2013-12-01

    We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. In addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.

  3. Hydration and Cooling Practices Among Farmworkers in Oregon and Washington

    PubMed Central

    Bethel, Jeffrey W.; Spector, June T.; Krenz, Jennifer

    2018-01-01

    Objectives Although recommendations for preventing occupational heat-related illness among farmworkers include hydration and cooling practices, the extent to which these recommendations are universally practiced is unknown. The objective of this analysis was to compare hydration and cooling practices between farmworkers in Oregon and Washington. Methods A survey was administered to a purposive sample of Oregon and Washington farmworkers. Data collected included demographics, work history and current work practices, hydration practices, access and use of cooling measures, and headwear and clothing worn. Results Oregon farmworkers were more likely than those in Washington to consume beverages containing sugar and/or caffeine. Workers in Oregon more frequently reported using various cooling measures compared with workers in Washington. Availability of cooling measures also varied between the two states. Conclusions These results highlight the large variability between workers in two states regarding access to and use of methods to stay cool while working in the heat. PMID:28402203

  4. Assessing body composition in infants and toddlers

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to compare different body composition techniques in infants and toddlers. Anthropometric measures including mid-upper arm circumference (MAC), triceps skinfold thickness (TSF), and weight-for-height or -length Z-scores (WHZ), and measures of body fat mass assessed wit...

  5. Jonckheere Double Star Photometry - Part VII: Aquarius

    NASA Astrophysics Data System (ADS)

    Knapp, Wilfried R. A.

    2017-10-01

    If any double star discoverer is in urgent need of photometry then it is Jonckheere. There are over 3000 Jonckheere objects listed in the WDS catalog and a good part of them with magnitudes obviously far too bright. This report covers the Jonckheere objects in the constellation Aquarius. One image per object was taken with V-filter to allow for visual magnitude measurement by differential pho-tometry. All objects were additionally checked for common proper motion by comparing 2MASS to GAIA DR1 positions and a rather surprisingly large part of the objects qualify indeed as potential CPM pairs. For a few objects also WDS position errors were found.

  6. Accuracy Assessment of Underwater Photogrammetric Three Dimensional Modelling for Coral Reefs

    NASA Astrophysics Data System (ADS)

    Guo, T.; Capra, A.; Troyer, M.; Gruen, A.; Brooks, A. J.; Hench, J. L.; Schmitt, R. J.; Holbrook, S. J.; Dubbini, M.

    2016-06-01

    Recent advances in automation of photogrammetric 3D modelling software packages have stimulated interest in reconstructing highly accurate 3D object geometry in unconventional environments such as underwater utilizing simple and low-cost camera systems. The accuracy of underwater 3D modelling is affected by more parameters than in single media cases. This study is part of a larger project on 3D measurements of temporal change of coral cover in tropical waters. It compares the accuracies of 3D point clouds generated by using images acquired from a system camera mounted in an underwater housing and the popular GoPro cameras respectively. A precisely measured calibration frame was placed in the target scene in order to provide accurate control information and also quantify the errors of the modelling procedure. In addition, several objects (cinder blocks) with various shapes were arranged in the air and underwater and 3D point clouds were generated by automated image matching. These were further used to examine the relative accuracy of the point cloud generation by comparing the point clouds of the individual objects with the objects measured by the system camera in air (the best possible values). Given a working distance of about 1.5 m, the GoPro camera can achieve a relative accuracy of 1.3 mm in air and 2.0 mm in water. The system camera achieved an accuracy of 1.8 mm in water, which meets our requirements for coral measurement in this system.

  7. Universal Approximation by Using the Correntropy Objective Function.

    PubMed

    Nayyeri, Mojtaba; Sadoghi Yazdi, Hadi; Maskooki, Alaleh; Rouhani, Modjtaba

    2017-10-16

    Several objective functions have been proposed in the literature to adjust the input parameters of a node in constructive networks. Furthermore, many researchers have focused on the universal approximation capability of the network based on the existing objective functions. In this brief, we use a correntropy measure based on the sigmoid kernel in the objective function to adjust the input parameters of a newly added node in a cascade network. The proposed network is shown to be capable of approximating any continuous nonlinear mapping with probability one in a compact input sample space. Thus, the convergence is guaranteed. The performance of our method was compared with that of eight different objective functions, as well as with an existing one hidden layer feedforward network on several real regression data sets with and without impulsive noise. The experimental results indicate the benefits of using a correntropy measure in reducing the root mean square error and increasing the robustness to noise.

  8. Measuring the impact of pollution on property prices in Madrid: objective versus subjective pollution indicators in spatial models

    NASA Astrophysics Data System (ADS)

    Mínguez, Román; Montero, José-María; Fernández-Avilés, Gema

    2013-04-01

    Much work has been done in the context of the hedonic price theory to estimate the impact of air quality on housing prices. Research has employed objective measures of air quality, but only slightly confirms the hedonic theory in the best of cases: the implicit price function relating housing prices to air pollution will, ceteris paribus, be negatively sloped. This paper compares the performance of a spatial Durbin model when using both objective and subjective measures of pollution. On the one hand, we design an Air Pollution Indicator based on measured pollution as the objective measure of pollution. On the other hand, the subjective measure of pollution employed to characterize neighborhoods is the percentage of residents who declare that the neighborhood has serious pollution problems, the percentage being referred to as residents' perception of pollution. For comparison purposes, the empirical part of this research focuses on Madrid (Spain). The study employs a proprietary database containing information about the price and 27 characteristics of 11,796 owner-occupied single family homes. As far as the authors are aware, it is the largest database ever used to analyze the Madrid housing market. The results of the study clearly favor the use of subjective air quality measures.

  9. Lest we forget: comparing retrospective and prospective assessments of adverse childhood experiences in the prediction of adult health.

    PubMed

    Reuben, Aaron; Moffitt, Terrie E; Caspi, Avshalom; Belsky, Daniel W; Harrington, Honalee; Schroeder, Felix; Hogan, Sean; Ramrakha, Sandhya; Poulton, Richie; Danese, Andrea

    2016-10-01

    Adverse childhood experiences (ACEs; e.g. abuse, neglect, and parental loss) have been associated with increased risk for later-life disease and dysfunction using adults' retrospective self-reports of ACEs. Research should test whether associations between ACEs and health outcomes are the same for prospective and retrospective ACE measures. We estimated agreement between ACEs prospectively recorded throughout childhood (by Study staff at Study member ages 3, 5, 7, 9, 11, 13, and 15) and retrospectively recalled in adulthood (by Study members when they reached age 38), in the population-representative Dunedin cohort (N = 1,037). We related both retrospective and prospective ACE measures to physical, mental, cognitive, and social health at midlife measured through both objective (e.g. biomarkers and neuropsychological tests) and subjective (e.g. self-reported) means. Dunedin and U.S. Centers for Disease Control ACE distributions were similar. Retrospective and prospective measures of adversity showed moderate agreement (r = .47, p < .001; weighted Kappa = .31, 95% CI: .27-.35). Both associated with all midlife outcomes. As compared to prospective ACEs, retrospective ACEs showed stronger associations with life outcomes that were subjectively assessed, and weaker associations with life outcomes that were objectively assessed. Recalled ACEs and poor subjective outcomes were correlated regardless of whether prospectively recorded ACEs were evident. Individuals who recalled more ACEs than had been prospectively recorded were more neurotic than average, and individuals who recalled fewer ACEs than recorded were more agreeable. Prospective ACE records confirm associations between childhood adversity and negative life outcomes found previously using retrospective ACE reports. However, more agreeable and neurotic dispositions may, respectively, bias retrospective ACE measures toward underestimating the impact of adversity on objectively measured life outcomes and overestimating the impact of adversity on self-reported outcomes. Associations between personality factors and the propensity to recall adversity were extremely modest and warrant further investigation. Risk predictions based on retrospective ACE reports should utilize objective outcome measures. Where objective outcome measurements are difficult to obtain, correction factors may be warranted. © 2016 Association for Child and Adolescent Mental Health.

  10. Lest we forget: Comparing retrospective and prospective assessments of adverse childhood experiences in the prediction of adult health

    PubMed Central

    Reuben, Aaron; Moffitt, Terrie E.; Caspi, Avshalom; Belsky, Daniel W.; Harrington, Honalee; Schroeder, Felix; Hogan, Sean; Ramrakha, Sandhya; Poulton, Richie; Danese, Andrea

    2017-01-01

    Background Adverse childhood experiences (ACEs; e.g., abuse, neglect, parental loss, etc.) have been associated with increased risk for later-life disease and dysfunction using adults’ retrospective self-reports of ACEs. Research should test whether associations between ACEs and health outcomes are the same for prospective and retrospective ACE measures. Methods We estimated agreement between ACEs prospectively-recorded throughout childhood (by Study staff at Study member ages 3, 5, 7, 9, 11, 13, and 15) and retrospectively-recalled in adulthood (by Study members when they reached age 38), in the population-representative Dunedin cohort (N=1,037). We related both retrospective and prospective ACE measures to physical, mental, cognitive, and social health at midlife measured through both objective (e.g., biomarkers and neuropsychological tests) and subjective (e.g., self-reported) means. Results Dunedin and CDC ACE distributions were similar. Retrospective and prospective measures of adversity showed moderate agreement (r=.47, p<.001; weighted Kappa = .31, 95% CI: .27–.35). Both associated with all midlife outcomes. As compared to prospective ACEs, retrospective ACEs showed stronger associations with life outcomes that were subjectively assessed, and weaker associations with life outcomes that were objectively assessed. Recalled ACEs and poor subjective outcomes were correlated regardless of whether prospectively-recorded ACEs were evident. Individuals who recalled more ACEs than had been prospectively recorded were more neurotic than average, and individuals who recalled fewer ACEs than recorded were more agreeable. Conclusions Prospective ACE records confirm associations between childhood adversity and negative life outcomes found previously using retrospective ACE reports. However, more agreeable and neurotic dispositions may respectively bias retrospective ACE measures toward underestimating the impact of adversity on objectively-measured life outcomes and overestimating the impact of adversity on self-reported outcomes. Associations between personality factors and the propensity to recall adversity were extremely modest and warrant further investigation. Risk predictions based on retrospective ACE reports should utilize objective outcome measures. Where objective outcome measurements are difficult to obtain, correction factors may be warranted. PMID:27647050

  11. The Vanderbilt Expertise Test Reveals Domain-General and Domain-Specific Sex Effects in Object Recognition

    PubMed Central

    McGugin, Rankin W.; Richler, Jennifer J.; Herzmann, Grit; Speegle, Magen; Gauthier, Isabel

    2012-01-01

    Individual differences in face recognition are often contrasted with differences in object recognition using a single object category. Likewise, individual differences in perceptual expertise for a given object domain have typically been measured relative to only a single category baseline. In Experiment 1, we present a new test of object recognition, the Vanderbilt Expertise Test (VET), which is comparable in methods to the Cambridge Face Memory Task (CFMT) but uses eight different object categories. Principal component analysis reveals that the underlying structure of the VET can be largely explained by two independent factors, which demonstrate good reliability and capture interesting sex differences inherent in the VET structure. In Experiment 2, we show how the VET can be used to separate domain-specific from domain-general contributions to a standard measure of perceptual expertise. While domain-specific contributions are found for car matching for both men and women and for plane matching in men, women in this sample appear to use more domain-general strategies to match planes. In Experiment 3, we use the VET to demonstrate that holistic processing of faces predicts face recognition independently of general object recognition ability, which has a sex-specific contribution to face recognition. Overall, the results suggest that the VET is a reliable and valid measure of object recognition abilities and can measure both domain-general skills and domain-specific expertise, which were both found to depend on the sex of observers. PMID:22877929

  12. Objective measures of sleep duration and continuity in major depressive disorder with comorbid hypersomnolence: a primary investigation with contiguous systematic review and meta-analysis.

    PubMed

    Plante, David T; Cook, Jesse D; Goldstein, Michael R

    2017-06-01

    Hypersomnolence plays an important role in the presentation, treatment and course of mood disorders. However, there has been relatively little research that examines objective measures of sleep duration and continuity in patients with depression and hypersomnolence, despite the use of these factors in sleep medicine nosological systems. This study compared total sleep time and efficiency measured by naturalistic actigraphic recordings followed by ad libitum polysomnography (PSG; without prescribed wake time) in 22 patients with major depressive disorder and co-occurring hypersomnolence against age- and sex-matched healthy sleeper controls. The major depressive disorder and co-occurring hypersomnolence group demonstrated significantly longer sleep duration compared with healthy sleeper controls quantified by sleep diaries, actigraphy and ad libitum PSG. No between-group differences in sleep efficiency (SE), latency to sleep or wake after sleep onset were observed when assessed using objective measures. To further contextualize these findings within the broader scientific literature, a systematic review was performed to identify other comparable investigations. A meta-analysis of pooled data demonstrated patients with mood disorders and co-occurring hypersomnolence have significantly greater sleep duration and similar SE compared with healthy controls when assessed using ad libitum PSG. These results suggest current sleep medicine nosology that distinguishes hypersomnia associated with psychiatric disorders primarily as a construct characterized by low SE and increased time in bed may not be accurate. Future studies that establish the biological bases hypersomnolence in mood disorders, as well as clarify the accuracy of nosological thresholds to define excessive sleep duration, are needed to refine the diagnosis and treatment of these disorders. © 2017 European Sleep Research Society.

  13. Objective Measures of Sleep Duration and Continuity in Major Depressive Disorder with Comorbid Hypersomnolence: A Primary Investigation with Contiguous Systematic Review and Meta-Analysis

    PubMed Central

    Plante, David T.; Cook, Jesse D.; Goldstein, Michael R.

    2016-01-01

    SUMMARY Hypersomnolence plays an important role in the presentation, treatment, and course of mood disorders. However, there has been relatively little research that examines objective measures of sleep duration and continuity in patients with depression and hypersomnolence, despite the use of these factors in sleep medicine nosological systems. This study compared total sleep time and efficiency measured by naturalistic actigraphic recordings followed by ad libitum polysomnography (without prescribed wake time) in twenty-two patients with major depressive disorder and co-occurring hypersomnolence (MDD-HYP) against age- and sex-matched healthy sleeper controls (HC). MDD-HYP demonstrated significantly longer sleep duration compared to HC quantified by sleep diaries, actigraphy, and ad libitum polysomnography. No between-group differences in sleep efficiency, latency to sleep, or wake after sleep onset were observed when assessed using objective measures. To further contextualize these findings within the broader scientific literature, a systematic review was performed to identify other comparable investigations. Meta-analysis of pooled data demonstrated patients with mood disorders and co-occurring hypersomnolence have significantly greater sleep duration and similar sleep efficiency compared to healthy controls when assessed using ad libitum polysomnography. These results suggest current sleep medicine nosology that distinguishes hypersomnia associated with psychiatric disorders primarily as a construct characterized by low sleep efficiency and increased time in bed may not be accurate. Future studies that establish the biological bases hypersomnolence in mood disorders, as well as clarify the accuracy of nosological thresholds to define excessive sleep duration, are needed to refine the diagnosis and treatment of these disorders. PMID:28145043

  14. Dynamic Reconstruction Algorithm of Three-Dimensional Temperature Field Measurement by Acoustic Tomography

    PubMed Central

    Li, Yanqiu; Liu, Shi; Inaki, Schlaberg H.

    2017-01-01

    Accuracy and speed of algorithms play an important role in the reconstruction of temperature field measurements by acoustic tomography. Existing algorithms are based on static models which only consider the measurement information. A dynamic model of three-dimensional temperature reconstruction by acoustic tomography is established in this paper. A dynamic algorithm is proposed considering both acoustic measurement information and the dynamic evolution information of the temperature field. An objective function is built which fuses measurement information and the space constraint of the temperature field with its dynamic evolution information. Robust estimation is used to extend the objective function. The method combines a tunneling algorithm and a local minimization technique to solve the objective function. Numerical simulations show that the image quality and noise immunity of the dynamic reconstruction algorithm are better when compared with static algorithms such as least square method, algebraic reconstruction technique and standard Tikhonov regularization algorithms. An effective method is provided for temperature field reconstruction by acoustic tomography. PMID:28895930

  15. Comprehensive Achievement Monitoring for Science. Symposium; National Association of Biology Teachers, San Francisco, California, October 27, 1972.

    ERIC Educational Resources Information Center

    White, Mona E.; And Others

    Comprehensive Achievement Monitoring (CAM) is a system designed to provide a curriculum defined in terms of performance objectives, test items to measure student performance on each objective, a set of comparable test forms to evaluate performance, testing throughout the period of the course, computerized analysis and reporting of results after…

  16. Objective Versus Subjective Measurement of Stress and Social Support: Combat-Related Reactions.

    ERIC Educational Resources Information Center

    Solomon, Zahava; And Others

    1987-01-01

    Studied combat intensity, social support, and related stress reactions among soldiers who fought in the 1982 Israeli-Lebanon War, comparing those who experienced combat stress reaction (N=382) and those who did not (N=344). Subjective indicators were found to be stronger predictors than were objective indicators. Combat stress reaction was clearly…

  17. Modeling 3-D objects with planar surfaces for prediction of electromagnetic scattering

    NASA Technical Reports Server (NTRS)

    Koch, M. B.; Beck, F. B.; Cockrell, C. R.

    1992-01-01

    Electromagnetic scattering analysis of objects at resonance is difficult because low frequency techniques are slow and computer intensive, and high frequency techniques may not be reliable. A new technique for predicting the electromagnetic backscatter from electrically conducting objects at resonance is studied. This technique is based on modeling three dimensional objects as a combination of flat plates where some of the plates are blocking the scattering from others. A cube is analyzed as a simple example. The preliminary results compare well with the Geometrical Theory of Diffraction and with measured data.

  18. Adverse Effects of Induced Hot Flashes on Objectively Recorded and Subjectively Reported Sleep: Results of a Gonadotropin-Releasing Hormone Agonist Experimental Protocol

    PubMed Central

    Joffe, Hadine; White, David P.; Crawford, Sybil L.; McCurnin, Kristin E.; Economou, Nicole; Connors, Stephanie; Hall, Janet E.

    2013-01-01

    Objectives The impact of hot flashes on sleep is of great clinical interest, but results are inconsistent, especially when both hot flashes and sleep are measured objectively. Using objective and subjective measurements, we examined the impact of hot flashes on sleep by inducing hot flashes with a gonadotropin-releasing hormone agonist (GnRHa). Methods The GnRHa leuprolide was administered to 20 healthy premenopausal volunteers without hot flashes or sleep disturbances. Induced hot flashes were assessed objectively (skin-conductance monitor) and subjectively (daily diary) during one-month follow-up. Changes from baseline in objective (actigraphy) and subjective sleep quality (Pittsburgh Sleep Quality Index [PSQI]) were compared between women who did and did not develop objective hot flashes, and, in parallel analyses, subjective hot flashes. Results New-onset hot flashes were recorded in 14 (70%) and reported by 14 (70%) women (80% concordance). Estradiol was universally suppressed. Objective sleep efficiency worsened in women with objective hot flashes and improved in women without objective hot flashes (median decrease 2.6%, increase 4.2%, p=0.005). Subjective sleep quality worsened more in those with than without subjective hot flashes (median increase PSQI 2.5 vs. 1.0, p=0.03). Objective hot flashes were not associated with subjective sleep quality, nor were subjective symptoms linked to objective sleep measures. Conclusions This experimental model of induced hot flashes demonstrates a causal relationship between hot flashes and poor sleep quality. Objective hot flashes result in worse objective sleep efficiency, while subjective hot flashes worsen perceived sleep quality. PMID:23481119

  19. The use of actigraphy in the monitoring of sleep and activity in ADHD: A meta-analysis.

    PubMed

    De Crescenzo, Franco; Licchelli, Serena; Ciabattini, Marco; Menghini, Deny; Armando, Marco; Alfieri, Paolo; Mazzone, Luigi; Pontrelli, Giuseppe; Livadiotti, Susanna; Foti, Francesca; Quested, Digby; Vicari, Stefano

    2016-04-01

    Attention deficit/hyperactivity disorder (ADHD) is the most common neurobehavioral disorder of childhood. There is an increasing need to find objective measures and markers of the disorder in order to assess the efficacy of the therapies and to improve follow-up strategies. Actigraphy is an objective method for recording motor activity and sleep parameters that has been used in many studies in ADHD. Our meta-analysis aimed to assess the current evidence on the role of actigraphy in both the detection of changes in motor activity and in sleep patterns in ADHD. A systematic review was carried out to find studies comparing children with unmedicated ADHD versus controls, using actigraphic measures as an outcome. The primary outcome measures were "sleep duration" and daytime "activity mean". As secondary outcome measures we analyzed "sleep onset latency", "sleep efficiency" and "wake after sleep onset". Twenty-four studies comprising 2179 children were included in this review. We show evidence that ADHD compared to typically developing children present a higher mean activity during structured sessions, a similar sleep duration, and a moderately altered sleep pattern. This study highlights the role of actigraphy as an objective tool for the ambulatory monitoring of sleep and activity in ADHD. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Evaluation of macrozone dimensions by ultrasound and EBSD techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreau, Andre, E-mail: Andre.Moreau@cnrc-nrc.gc.ca; Toubal, Lotfi; Ecole de technologie superieure, 1100, rue Notre-Dame Ouest, Montreal, QC, Canada H3C 1K3

    2013-01-15

    Titanium alloys are known to have texture heterogeneities, i.e. regions much larger than the grain dimensions, where the local orientation distribution of the grains differs from one region to the next. The electron backscattering diffraction (EBSD) technique is the method of choice to characterize these macro regions, which are called macrozones. Qualitatively, the images obtained by EBSD show that these macrozones may be larger or smaller, elongated or equiaxed. However, often no well-defined boundaries are observed between the macrozones and it is very hard to obtain objective and quantitative estimates of the macrozone dimensions from these data. In the presentmore » work, we present a novel, non-destructive ultrasonic technique that provides objective and quantitative characteristic dimensions of the macrozones. The obtained dimensions are based on the spatial autocorrelation function of fluctuations in the sound velocity. Thus, a pragmatic definition of macrozone dimensions naturally arises from the ultrasonic measurement. This paper has three objectives: 1) to disclose the novel, non-destructive ultrasonic technique to measure macrozone dimensions, 2) to propose a quantitative and objective definition of macrozone dimensions adapted to and arising from the ultrasonic measurement, and which is also applicable to the orientation data obtained by EBSD, and 3) to compare the macrozone dimensions obtained using the two techniques on two samples of the near-alpha titanium alloy IMI834. In addition, it was observed that macrozones may present a semi-periodical arrangement. - Highlights: Black-Right-Pointing-Pointer Discloses a novel, ultrasonic NDT technique to measure macrozone dimensions Black-Right-Pointing-Pointer Proposes a quantitative and objective definition of macrozone dimensions Black-Right-Pointing-Pointer Compares macrozone dimensions obtained using EBSD and ultrasonics on 2 Ti samples Black-Right-Pointing-Pointer Observes that macrozones may have a semi-periodical arrangement.« less

  1. The role of objective personality inventories in suicide risk assessment: an evaluation and proposal.

    PubMed

    Johnson, W B; Lall, R; Bongar, B; Nordlund, M D

    1999-01-01

    Objective personality assessment instruments offer a comparatively underutilized source of clinical data in attempts to evaluate and predict risk for suicide. In contrast to focal suicide risk measures, global personality inventories may be useful in identification of long-standing styles that predispose persons to eventual suicidal behavior. This article reviews the empirical literature regarding the efficacy of established personality inventories in predicting suicidality. The authors offer several recommendations for future research with these measures and conclude that such objective personality instruments offer only marginal utility as sources of clinical information in comprehensive suicide risk evaluations. Personality inventories may offer greatest utility in long-term assessment of suicide risk.

  2. Determining characteristics of artificial near-Earth objects using observability analysis

    NASA Astrophysics Data System (ADS)

    Friedman, Alex M.; Frueh, Carolin

    2018-03-01

    Observability analysis is a method for determining whether a chosen state of a system can be determined from the output or measurements. Knowledge of state information availability resulting from observability analysis leads to improved sensor tasking for observation of orbital debris and better control of active spacecraft. This research performs numerical observability analysis of artificial near-Earth objects. Analysis of linearization methods and state transition matrices is performed to determine the viability of applying linear observability methods to the nonlinear orbit problem. Furthermore, pre-whitening is implemented to reformulate classical observability analysis. In addition, the state in observability analysis is typically composed of position and velocity; however, including object characteristics beyond position and velocity can be crucial for precise orbit propagation. For example, solar radiation pressure has a significant impact on the orbit of high area-to-mass ratio objects in geosynchronous orbit. Therefore, determining the time required for solar radiation pressure parameters to become observable is important for understanding debris objects. In order to compare observability analysis results with and without measurement noise and an extended state, quantitative measures of observability are investigated and implemented.

  3. Objective but Not Subjective Short Sleep Duration Associated with Increased Risk for Hypertension in Individuals with Insomnia

    PubMed Central

    Bathgate, Christina J.; Edinger, Jack D.; Wyatt, James K.; Krystal, Andrew D.

    2016-01-01

    Study Objectives: To examine the relationship between hypertension prevalence in individuals with insomnia who have short total sleep duration < 6 h or sleep duration ≥ 6 h, using both objective and subjective measures of total sleep duration. Methods: Using a cross-sectional, observational design, 255 adult volunteers (n = 165 women; 64.7%) meeting current diagnostic criteria for insomnia disorder (MAge = 46.2 y, SDAge = 13.7 y) participated in this study at two large university medical centers. Two nights of polysomnography, 2 w of sleep diaries, questionnaires focused on sleep, medical, psychological, and health history, including presence/absence of hypertension were collected. Logistic regressions assessed the odds ratios of hypertension among persons with insomnia with short sleep duration < 6 h compared to persons with insomnia with a sleep duration ≥ 6 h, measured both objectively and subjectively. Results: Consistent with previous studies using objective total sleep duration, individuals with insomnia and short sleep duration < 6 h were associated with a 3.59 increased risk of reporting hypertension as a current medical problem as compared to individuals with insomnia with sleep duration ≥ 6 h. Increased risk for hypertension was independent of major confounding factors frequently associated with insomnia or hypertension. No significant risk was observed using subjectively determined total sleep time groups. Receiver operating characteristic curve analysis found that the best balance of sensitivity and specificity using subjective total sleep time was at a 6-h cutoff, but the area under the receiver operating characteristic curve showed low accuracy and did not have good discriminant value. Conclusions: Objectively measured short sleep duration increased the odds of reporting hypertension more than threefold after adjusting for potential confounders; this relationship was not significant for subjectively measured sleep duration. This research supports emerging evidence that insomnia with objective short sleep duration is associated with an increased risk of comorbid hypertension. Citation: Bathgate CJ, Edinger JD, Wyatt JK, Krystal AD. Objective but not subjective short sleep duration associated with increased risk for hypertension in individuals with insomnia. SLEEP 2016;39(5):1037–1045. PMID:26951399

  4. Sway Area and Velocity Correlated With MobileMat Balance Error Scoring System (BESS) Scores.

    PubMed

    Caccese, Jaclyn B; Buckley, Thomas A; Kaminski, Thomas W

    2016-08-01

    The Balance Error Scoring System (BESS) is often used for sport-related concussion balance assessment. However, moderate intratester and intertester reliability may cause low initial sensitivity, suggesting that a more objective balance assessment method is needed. The MobileMat BESS was designed for objective BESS scoring, but the outcome measures must be validated with reliable balance measures. Thus, the purpose of this investigation was to compare MobileMat BESS scores to linear and nonlinear measures of balance. Eighty-eight healthy collegiate student-athletes (age: 20.0 ± 1.4 y, height: 177.7 ± 10.7 cm, mass: 74.8 ± 13.7 kg) completed the MobileMat BESS. MobileMat BESS scores were compared with 95% area, sway velocity, approximate entropy, and sample entropy. MobileMat BESS scores were significantly correlated with 95% area for single-leg (r = .332) and tandem firm (r = .474), and double-leg foam (r = .660); and with sway velocity for single-leg (r = .406) and tandem firm (r = .601), and double-leg (r = .575) and single-leg foam (r = .434). MobileMat BESS scores were not correlated with approximate or sample entropy. MobileMat BESS scores were low to moderately correlated with linear measures, suggesting the ability to identify changes in the center of mass-center of pressure relationship, but not higher-order processing associated with nonlinear measures. These results suggest that the MobileMat BESS may be a clinically-useful tool that provides objective linear balance measures.

  5. Objective Measurement of Vocal Fatigue in Classically Trained Singers: A Pilot Study of Vocal Dosimetry Data

    PubMed Central

    Carroll, Thomas; Nix, John; Hunter, Eric; Titze, Ingo; Abaza, Mona

    2016-01-01

    Objectives To evaluate vocal fatigue by using objective and subjective measurements of dose recorded by the National Center for Voice and Speech (NCVS) Dosimeter™ (Dosimeter). Study Design and Setting Seven subjects completed a two-week study period. The Dosimeter recorded vocal load, soft phonation tasks and subjective soft voice ratings. Three vocal doses (time, distance, and cycle) were measured in classical singers' larynges during an intensive practice period. Results Spikes in vocal load are reflected as harsher subjective ratings on the same day as well as 24–72 hours later. When at least 48 hours of vocal rest occurred before a vocal load, improved subjective evaluations were seen after the load. Conclusions The NCVS Dosimeter appears to be an effective tool for data collection on prolonged use of the voice. Significance This is the first multi-day study comparing objective and subjective data on vocal fatigue in a group of professional singers. PMID:17011424

  6. Objective reports versus subjective perceptions of crime and their relationships to accelerometer-measured physical activity in Hispanic caretaker-child dyads.

    PubMed

    van Bakergem, Margaret; Sommer, Evan C; Heerman, William J; Hipp, James Aaron; Barkin, Shari L

    2017-02-01

    Crime and safety are commonly cited barriers to physical activity (PA). We had three objectives, 1) describe the association between objective crime measures and perceptions of crime, 2) analyze the relationships between each type of crime and accelerometer-measured physical activity in caretakers and young children (ages 3-5years), and 3) explore for early gender differences in the relationship between crime and physical activity in young children. Data are from the cross-sectional baseline data of an ongoing randomized controlled trial in Nashville, Tennessee spanning September 2012 through May 2014. Data was analyzed from 480 Hispanic dyads (adult caretaker and 3-5year old child). Objective crime rate was assessed in ArcGIS and perception of crime was measured by caretaker agreement with the statement "The crime rate in my neighborhood makes it unsafe to go on walks." The primary outcome was accelerometer-measured physical activity over seven consecutive days. Objective and perceived crime were significantly positively correlated. Caretaker vigorous PA was significantly related to perceptions of crime; however, its relationship to objective crime was not significant. Child PA was not significantly related to caretaker perceptions of crime. However, interactions suggested that the relationship between crime rate and PA was significantly more negative for girls than for boys. Objective and subjective measures of crime rate are expected to be important correlates of PA, but they appear to have complex relationships that are different for adults than they are for young children, as well as for young girls compared to boys, and research has produced conflicting findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Objective reports versus subjective perceptions of crime and their relationships to accelerometer-measured physical activity in Hispanic caretaker-child dyads

    PubMed Central

    van Bakergem, Margaret; Sommer, Evan C.; Heerman, William J.; Hipp, James Aaron; Barkin, Shari L.

    2016-01-01

    Crime and safety are commonly cited barriers to physical activity (PA). We had three objectives, 1) describe the association between objective crime measures and perceptions of crime, 2) analyze the relationships between each type of crime and accelerometer-measured physical activity in caretakers and young children (ages 3–5 years), and 3) explore for early gender differences in the relationship between crime and physical activity in young children. Data are from the cross-sectional baseline data of an ongoing randomized controlled trial in Nashville, Tennessee spanning September 2012 through May 2014. Data was analyzed from 480 Hispanic dyads (adult caretaker and 3–5 year old child). Objective crime rate was assessed in ArcGIS and perception of crime was measured by caretaker agreement with the statement “The crime rate in my neighborhood makes it unsafe to go on walks.” The primary outcome was accelerometer-measured physical activity over seven consecutive days. Objective and perceived crime were significantly positively correlated. Caretaker vigorous PA was significantly related to perceptions of crime; however, its relationship to objective crime was not significant. Child PA was not significantly related to caretaker perceptions of crime. However, interactions suggested that the relationship between crime rate and PA was significantly more negative for girls than for boys. Objective and subjective measures of crime rate are expected to be important correlates of PA, but they appear to have complex relationships that are different for adults than they are for young children, as well as for young girls compared to boys, and research has produced conflicting findings. PMID:27939263

  8. The effect of two types of memory training on subjective and objective memory performance in healthy individuals aged 55 years and older: a randomized controlled trial.

    PubMed

    Valentijn, Susanne A M; van Hooren, Susan A H; Bosma, Hans; Touw, Dory M; Jolles, Jelle; van Boxtel, Martin P J; Ponds, Rudolf W H M

    2005-04-01

    The objective of the study was to examine the effectiveness of two types of memory training (collective and individual), compared to control (waiting list), on memory performance. Participants were 139 community-dwelling older individuals recruited through media advertisements asking for people with subjective memory complaints to participate in a study. Data were collected at baseline, and at 1 week and 4 months after the intervention. Training efficacy was assessed using measures of subjective and objective memory performance. After the intervention, participants in the collective training group reported more stability in memory functioning and had fewer feelings of anxiety and stress about memory functioning. In addition, positive effects were found on objective memory functioning. Compared with the other two groups, the collective training group participants had an improved recall of a previously learned word list. Compared to controls, participants in the individual training group reported fewer feelings of anxiety and stress in relation to memory functioning.

  9. From Hipparcos to Gaia

    NASA Astrophysics Data System (ADS)

    Eyer, L.; Dubath, P.; Saesen, S.; Evans, D. W.; Wyrzykowski, L.; Hodgkin, S.; Mowlavi, N.

    2012-04-01

    The measurement of the positions, distances, motions and luminosities of stars represents the foundations of modern astronomical knowledge. Launched at the end of the eighties, the ESA Hipparcos satellite was the first space mission dedicated to such measurements. Hipparcos improved position accuracies by a factor of 100 compared to typical ground-based results and provided astrometric and photometric multi-epoch observations of 118,000 stars over the entire sky. The impact of Hipparcos on astrophysics has been extremely valuable and diverse. Building on this important European success, the ESA Gaia cornerstone mission promises an even more impressive advance. Compared to Hipparcos, it will bring a gain of a factor 50 to 100 in position accuracy and of a factor of 10,000 in star number, collecting photometric, spectrophotometric and spectroscopic data for one billion celestial objects. During its 5-year flight, Gaia will measure objects repeatedly, up to a few hundred times, providing an unprecedented database to study the variability of all types of celestial objects. Gaia will bring outstanding contributions, directly or indirectly, to most fields of research in astrophysics, such as the study of our Galaxy and of its stellar constituents, and the search for planets outside the solar system.

  10. Testing the utility of three social-cognitive models for predicting objective and self-report physical activity in adults with type 2 diabetes.

    PubMed

    Plotnikoff, Ronald C; Lubans, David R; Penfold, Chris M; Courneya, Kerry S

    2014-05-01

    Theory-based interventions to promote physical activity (PA) are more effective than atheoretical approaches; however, the comparative utility of theoretical models is rarely tested in longitudinal designs with multiple time points. Further, there is limited research that has simultaneously tested social-cognitive models with self-report and objective PA measures. The primary aim of this study was to test the predictive ability of three theoretical models (social cognitive theory, theory of planned behaviour, and protection motivation theory) in explaining PA behaviour. Participants were adults with type 2 diabetes (n = 287, 53.8% males, mean age = 61.6 ± 11.8 years). Theoretical constructs across the three theories were tested to prospectively predict PA behaviour (objective and self-report) across three 6-month time intervals (baseline-6, 6-12, 12-18 months) using structural equation modelling. PA outcomes were steps/3 days (objective) and minutes of MET-weighted PA/week (self-report). The mean proportion of variance in PA explained by these models was 6.5% for objective PA and 8.8% for self-report PA. Direct pathways to PA outcomes were stronger for self-report compared with objective PA. These theories explained a small proportion of the variance in longitudinal PA studies. Theory development to guide interventions for increasing and maintaining PA in adults with type 2 diabetes requires further research with objective measures. Theory integration across social-cognitive models and the inclusion of ecological levels are recommended to further explain PA behaviour change in this population. Statement of contribution What is already known on this subject? Social-cognitive theories are able to explain partial variance for physical activity (PA) behaviour. What does this study add? The testing of three theories in a longitudinal design over 3, 6-month time intervals. The parallel use and comparison of both objective and self-report PA measures in testing these theories. © 2013 The British Psychological Society.

  11. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    PubMed

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  12. Subjective and objective quantification of physician's workload and performance during radiation therapy planning tasks.

    PubMed

    Mazur, Lukasz M; Mosaly, Prithima R; Hoyle, Lesley M; Jones, Ellen L; Marks, Lawrence B

    2013-01-01

    To quantify, and compare, workload for several common physician-based treatment planning tasks using objective and subjective measures of workload. To assess the relationship between workload and performance to define workload levels where performance could be expected to decline. Nine physicians performed the same 3 tasks on each of 2 cases ("easy" vs "hard"). Workload was assessed objectively throughout the tasks (via monitoring of pupil size and blink rate), and subjectively at the end of each case (via National Aeronautics and Space Administration Task Load Index; NASA-TLX). NASA-TLX assesses the 6 dimensions (mental, physical, and temporal demands, frustration, effort, and performance); scores > or ≈ 50 are associated with reduced performance in other industries. Performance was measured using participants' stated willingness to approve the treatment plan. Differences in subjective and objective workload between cases, tasks, and experience were assessed using analysis of variance (ANOVA). The correlation between subjective and objective workload measures were assessed via the Pearson correlation test. The relationships between workload and performance measures were assessed using the t test. Eighteen case-wise and 54 task-wise assessments were obtained. Subjective NASA-TLX scores (P < .001), but not time-weighted averages of objective scores (P > .1), were significantly lower for the easy vs hard case. Most correlations between the subjective and objective measures were not significant, except between average blink rate and NASA-TLX scores (r = -0.34, P = .02), for task-wise assessments. Performance appeared to decline at NASA-TLX scores of ≥55. The NASA-TLX may provide a reasonable method to quantify subjective workload for broad activities, and objective physiologic eye-based measures may be useful to monitor workload for more granular tasks within activities. The subjective and objective measures, as herein quantified, do not necessarily track each other, and more work is needed to assess their utilities. From a series of controlled experiments, we found that performance appears to decline at subjective workload levels ≥55 (as measured via NASA-TLX), which is consistent with findings from other industries. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  13. Patient-specific optimisation of administered activity and acquisition times for 18F-FDG PET imaging.

    PubMed

    Wickham, Fred; McMeekin, Helena; Burniston, Maria; McCool, Daniel; Pencharz, Deborah; Skillen, Annah; Wagner, Thomas

    2017-12-01

    The purpose of this study is to identify a method for optimising the administered activity and acquisition time for 18 F-FDG PET imaging, yielding images of consistent quality for patients with varying body sizes and compositions, while limiting radiation doses to patients and staff. Patients referred for FDG scans had bioimpedance measurements. They were injected with 3 MBq/kg of 18 F up to 370 MBq and scanned on a Siemens Biograph mCT at 3 or 4 min per bed position. Data were rebinned to simulate 2- and 1-min acquisitions. Subjective assessments of image quality made by an experienced physician were compared with objective measurements based on signal-to-noise ratio and noise equivalent counts (NEC). A target objective measure of image quality was identified. The activity and acquisition time required to achieve this were calculated for each subject. Multiple regression analysis was used to identify expressions for the activity and acquisition time required in terms of easily measurable patient characteristics. One hundred and eleven patients were recruited, and subjective and objective assessments of image quality were compared for 321 full and reduced time scans. NEC-per-metre was identified as the objective measure which best correlated with the subjective assessment (Spearman rank correlation coefficient 0.77) and the best discriminator for images with a subjective assessment of "definitely adequate" (area under the ROC curve 0.94). A target of 37 Mcount/m was identified. Expressions were identified in terms of patient sex, height and weight for the activity and acquisition time required to achieve this target. Including measurements of body composition in these expressions was not useful. Using these expressions would reduce the mean activity administered to this patient group by 66 MBq compared to the current protocol. Expressions have been identified for the activity and acquisition times required to achieve consistent image quality in FDG imaging with reduced patient and staff doses. These expressions might need to be adapted for other systems and reconstruction protocols.

  14. An examination of presenteeism measures: the association of three scoring methods with health, work life, and consumer activation.

    PubMed

    Terry, Paul E; Xi, Min

    2010-12-01

    The objective of this study was to assess the validity of 3 scoring techniques for presenteeism measures by exploring their relationship with patient activation, health, job satisfaction, and socioeconomic characteristics. The sample consisted of 631 employees from 2 predominantly white-collar employee groups in the northern Midwest. Employees completed the World Health Organization's Health and Work Performance Questionnaire, a wellness profile, and the Patient Activation Measure. Absolute measures reflect self-rated performance, while relative and stratified measures compare self-rated performance to that of co-workers. Multivariate analyses were used to validate scoring measures. All measures of presenteeism were positively correlated with being nonwhite, income, and smoking. The significance of age, employment, mental health, and patient activation depends on how presenteeism is defined. Practitioners must carefully consider which scoring method best addresses their program goals and objectives. Clearer measurement guidelines are needed.

  15. Initial Description of a Quantitative, Cross-Species (Chimpanzee-Human) Social Responsiveness Measure

    ERIC Educational Resources Information Center

    Marrus, Natasha; Faughn, Carley; Shuman, Jeremy; Petersen, Steve E.; Constantino, John N.; Povinelli, Daniel J.; Pruett, John R., Jr.

    2011-01-01

    Objective: Comparative studies of social responsiveness, an ability that is impaired in autism spectrum disorders, can inform our understanding of both autism and the cognitive architecture of social behavior. Because there is no existing quantitative measure of social responsiveness in chimpanzees, we generated a quantitative, cross-species…

  16. Using measures of information content and complexity of time series as hydrologic metrics

    USDA-ARS?s Scientific Manuscript database

    The information theory has been previously used to develop metrics that allowed to characterize temporal patterns in soil moisture dynamics, and to evaluate and to compare performance of soil water flow models. The objective of this study was to apply information and complexity measures to characte...

  17. Objective but Not Subjective Short Sleep Duration Associated with Increased Risk for Hypertension in Individuals with Insomnia.

    PubMed

    Bathgate, Christina J; Edinger, Jack D; Wyatt, James K; Krystal, Andrew D

    2016-05-01

    To examine the relationship between hypertension prevalence in individuals with insomnia who have short total sleep duration < 6 h or sleep duration ≥ 6 h, using both objective and subjective measures of total sleep duration. Using a cross-sectional, observational design, 255 adult volunteers (n = 165 women; 64.7%) meeting current diagnostic criteria for insomnia disorder (MAge = 46.2 y, SDAge = 13.7 y) participated in this study at two large university medical centers. Two nights of polysomnography, 2 w of sleep diaries, questionnaires focused on sleep, medical, psychological, and health history, including presence/absence of hypertension were collected. Logistic regressions assessed the odds ratios of hypertension among persons with insomnia with short sleep duration < 6 h compared to persons with insomnia with a sleep duration ≥ 6 h, measured both objectively and subjectively. Consistent with previous studies using objective total sleep duration, individuals with insomnia and short sleep duration < 6 h were associated with a 3.59 increased risk of reporting hypertension as a current medical problem as compared to individuals with insomnia with sleep duration ≥ 6 h. Increased risk for hypertension was independent of major confounding factors frequently associated with insomnia or hypertension. No significant risk was observed using subjectively determined total sleep time groups. Receiver operating characteristic curve analysis found that the best balance of sensitivity and specificity using subjective total sleep time was at a 6-h cutoff, but the area under the receiver operating characteristic curve showed low accuracy and did not have good discriminant value. Objectively measured short sleep duration increased the odds of reporting hypertension more than threefold after adjusting for potential confounders; this relationship was not significant for subjectively measured sleep duration. This research supports emerging evidence that insomnia with objective short sleep duration is associated with an increased risk of comorbid hypertension. © 2016 Associated Professional Sleep Societies, LLC.

  18. Body Density Estimates from Upper-Body Skinfold Thicknesses Compared to Air-Displacement Plethysmography

    USDA-ARS?s Scientific Manuscript database

    Technical Summary Objectives: Determine the effect of body mass index (BMI) on the accuracy of body density (Db) estimated with skinfold thickness (SFT) measurements compared to air displacement plethysmography (ADP) in adults. Subjects/Methods: We estimated Db with SFT and ADP in 131 healthy men an...

  19. Theory of planned behaviour variables and objective walking behaviour do not show seasonal variation in a randomised controlled trial.

    PubMed

    Williams, Stefanie L; French, David P

    2014-02-05

    Longitudinal studies have shown that objectively measured walking behaviour is subject to seasonal variation, with people walking more in summer compared to winter. Seasonality therefore may have the potential to bias the results of randomised controlled trials if there are not adequate statistical or design controls. Despite this there are no studies that assess the impact of seasonality on walking behaviour in a randomised controlled trial, to quantify the extent of such bias. Further there have been no studies assessing how season impacts on the psychological predictors of walking behaviour to date. The aim of the present study was to assess seasonal differences in a) objective walking behaviour and b) Theory of Planned Behaviour (TPB) variables during a randomised controlled trial of an intervention to promote walking. 315 patients were recruited to a two-arm cluster randomised controlled trial of an intervention to promote walking in primary care. A series of repeated measures ANCOVAs were conducted to examine the effect of season on pedometer measures of walking behaviour and TPB measures, assessed immediately post-intervention and six months later. Hierarchical regression analyses were conducted to assess whether season moderated the prediction of intention and behaviour by TPB measures. There were no significant differences in time spent walking in spring/summer compared to autumn/winter. There was no significant seasonal variation in most TPB variables, although the belief that there will be good weather was significantly higher in spring/summer (F = 19.46, p < .001). Season did not significantly predict intention or objective walking behaviour, or moderate the effects of TPB variables on intention or behaviour. Seasonality does not influence objectively measured walking behaviour or psychological variables during a randomised controlled trial. Consequently physical activity behaviour outcomes in trials will not be biased by the season in which they are measured. Previous studies may have overestimated the extent of seasonality effects by selecting the most extreme summer and winter months to assess PA. In addition, participants recruited to behaviour change interventions might have higher levels of motivation to change and are less affected by seasonal barriers. Current Controlled Trials ISRCTN95932902.

  20. Evaluation of experimental methods for assessing safety for ultrasound radiation force elastography.

    PubMed

    Skurczynski, M J; Duck, F A; Shipley, J A; Bamber, J C; Melodelima, D

    2009-08-01

    Standard test tools have been evaluated for the assessment of safety associated with a prototype transducer intended for a novel radiation force elastographic imaging system. In particular, safety has been evaluated by direct measurement of temperature rise, using a standard thermal test object, and detection of inertial cavitation from acoustic emission. These direct measurements have been compared with values of the thermal index and mechanical index, calculated from acoustic measurements in water using standard formulae. It is concluded that measurements using a thermal test object can be an effective alternative to the calculation of thermal index for evaluating thermal hazard. Measurement of the threshold for cavitation was subject to considerable variability, and it is concluded that the mechanical index still remains the preferred standard means for assessing cavitation hazard.

  1. The Use of Neutron Analysis Techniques for Detecting The Concentration And Distribution of Chloride Ions in Archaeological Iron

    PubMed Central

    Watkinson, D; Rimmer, M; Kasztovszky, Z; Kis, Z; Maróti, B; Szentmiklósi, L

    2014-01-01

    Chloride (Cl) ions diffuse into iron objects during burial and drive corrosion after excavation. Located under corrosion layers, Cl is inaccessible to many analytical techniques. Neutron analysis offers non-destructive avenues for determining Cl content and distribution in objects. A pilot study used prompt gamma activation analysis (PGAA) and prompt gamma activation imaging (PGAI) to analyse the bulk concentration and longitudinal distribution of Cl in archaeological iron objects. This correlated with the object corrosion rate measured by oxygen consumption, and compared well with Cl measurement using a specific ion meter. High-Cl areas were linked with visible damage to the corrosion layers and attack of the iron core. Neutron techniques have significant advantages in the analysis of archaeological metals, including penetration depth and low detection limits. PMID:26028670

  2. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    PubMed Central

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  3. Comparison of the VISX wavescan and OPD-scan III with the subjective refraction.

    PubMed

    Zhu, R; Long, K-L; Wu, X-M; Li, Q-D

    2016-07-01

    To compare the refractive errors measured by the VISX WaveScan, OPD-Scan III and the subjective refraction. The optometry accuracy of computer operated aberrometer used before refractive surgery has been debatable. Hence, a clear study on the role of such automated equipment in optometry is the need of the hour as compared to subjective refraction. Seventy-six patients (152 eyes) were recruited from January 2013 to December 2013. All patients were measured with subjective refraction by the phoropter (NIDEK, RT-5100), objective refraction by the WaveScan (AMO Company, USA), OPD-Scan III (Nidek Technologies, Japan). The sphere, cylinder, axis of the three methods were compared and analyzed. The diopter of sphere power measured by WaveScan was lower than that of the subjective refraction and the difference was 0.13 ± 0. 30D (t = 3. 753, p <0. 001). While the diopter of cylinder power was higher and the difference was 0.13 ±0.43D (t = 3. 664, p <0. 001). There was no significance for sphere, cylinder and spherical equivalent between OPD-Scan III and subjective refraction (p >0. 05). The value of the difference between WaveScan and subjective refraction was 5.87°±6.19°on average, while the difference between OPD-Scan III and subjective refraction was 3.82°±3.95°on average. The differences between the two were statistically significant (t =2. 817, p =0. 006). The results of sphere and cylinder measured by WaveScan and subjective refraction were different. As the latest integrated equipment, the Nidek OPD-Scan III gives a more accurate measurement of objective refraction when compared with subjective refraction. The latest Nidek OPD-Scan III may prove to be an useful tool for preoperative optometry deviation based on objective refraction.

  4. Using Comprehensive Achievement Monitoring in the Classroom. Symposium; California Educational Research Association, San Jose, California, November 9, 1972.

    ERIC Educational Resources Information Center

    Easter, John; And Others

    Comprehensive Achievement Monitoring (CAM) is a system designed to provide a curriculum defined in terms of performance objectives, test items to measure student performance on each objective, a set of comparable test forms to evaluate performance, testing throughout the period of the course, computerized analysis and reporting of results after…

  5. Comprehensive Achievement Monitoring in the Sequoia Union High School District. Symposium, California Educational Data Processing Association, December 8, 1972.

    ERIC Educational Resources Information Center

    Easter, John; And Others

    Comprehensive Achievement Monitoring (CAM) is a system designed to provide a curriculum defined in terms of performance objectives, test items to measure student performance on each objective, a set of comparable test forms to evaluate performance, testing throughout the period of course, computerized analysis and reporting of results after test…

  6. A Comparison of Quality of Life Outcomes for People with Intellectual Disabilities in Supported Employment, Day Services and Employment Enterprises

    ERIC Educational Resources Information Center

    Beyer, Stephen; Brown, Tony; Akandi, Rachel; Rapley, Mark

    2010-01-01

    Background: Policy objectives for people with intellectual disabilities include day service modernization and the promotion of paid employment and quality of life. Quality of life is under represented as an outcome measure in vocational research. This research compares subjective and objective quality of life, and quality of work environment for…

  7. Narrative Writing Competence and Internal State Terms of Young Adults Clinically Diagnosed with Childhood Attention Deficit Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Miranda, Ana; Baixauli, Inmaculada; Colomer, Carla

    2013-01-01

    Objective: The first objective of this study was to compare the written expression competence of young adults with attention deficit hyperactivity disorder (ADHD) with that of young adults without ADHD on three types of measures: indicators of the story's microstructure with regard to productivity and morphosyntax; indicators of the macrostructure…

  8. Multipoint vibrometry with dynamic and static holograms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haist, T.; Lingel, C.; Osten, W.

    2013-12-15

    We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. Inmore » addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.« less

  9. Experimental research of digital holographic microscopic measuring

    NASA Astrophysics Data System (ADS)

    Zhu, Xueliang; Chen, Feifei; Li, Jicheng

    2013-06-01

    Digital holography is a new imaging technique, which is developed on the base of optical holography, Digital processing, and Computer techniques. It is using CCD instead of the conventional silver to record hologram, and then reproducing the 3D contour of the object by the way of computer simulation. Compared with the traditional optical holographic, the whole process is of simple measuring, lower production cost, faster the imaging speed, and with the advantages of non-contact real-time measurement. At present, it can be used in the fields of the morphology detection of tiny objects, micro deformation analysis, and biological cells shape measurement. It is one of the research hot spot at home and abroad. This paper introduced the basic principles and relevant theories about the optical holography and Digital holography, and researched the basic questions which influence the reproduce images in the process of recording and reconstructing of the digital holographic microcopy. In order to get a clear digital hologram, by analyzing the optical system structure, we discussed the recording distance and of the hologram. On the base of the theoretical studies, we established a measurement and analyzed the experimental conditions, then adjusted them to the system. To achieve a precise measurement of tiny object in three-dimension, we measured MEMS micro device for example, and obtained the reproduction three-dimensional contour, realized the three dimensional profile measurement of tiny object. According to the experiment results consider: analysis the reference factors between the zero-order term and a pair of twin-images by the choice of the object light and the reference light and the distance of the recording and reconstructing and the characteristics of reconstruction light on the measurement, the measurement errors were analyzed. The research result shows that the device owns certain reliability.

  10. Bias effects of short- and long-term color memory for unique objects.

    PubMed

    Bloj, Marina; Weiß, David; Gegenfurtner, Karl R

    2016-04-01

    Are objects remembered with a more saturated color? Some of the evidence supporting this statement comes from research using "memory colors"-the typical colors of particular objects, for example, the green of grass. The problematic aspect of these findings is that many different exemplars exist, some of which might exhibit a higher saturation than the one measured by the experimenter. Here we avoid this problem by using unique personal items and comparing long- and short-term color memory matches (in hue, value, and chroma) with those obtained with the object present. Our results, on average, confirm that objects are remembered as more saturated than they are.

  11. Effect diffraction on a viewed object has on improvement of object optical image quality in a turbulent medium

    NASA Astrophysics Data System (ADS)

    Banakh, Viktor A.; Sazanovich, Valentina M.; Tsvik, Ruvim S.

    1997-09-01

    The influence of diffraction on the object, coherently illuminated and viewed through a random medium from the same point, on the image quality betterment caused by the counter wave correlation is studied experimentally. The measurements were carried out with the use of setup modeling artificial convective turbulence. It is shown that in the case of spatially limited reflector with the Fresnel number of the reflector surface radius r ranging from 3 to 12 the contribution of the counter wave correlation into image intensity distribution is maximal as compared with the point objects (r U.

  12. Learning-Related Cognitive Self-Regulation Measures for Prekindergarten Children: A Comparative Evaluation of the Educational Relevance of Selected Measures

    ERIC Educational Resources Information Center

    Lipsey, Mark W.; Nesbitt, Kimberly Turner; Farran, Dale C.; Dong, Nianbo; Fuhs, Mary Wagner; Wilson, Sandra Jo

    2017-01-01

    Many cognitive self-regulation (CSR) measures are related to the academic achievement of prekindergarten children and are thus of potential interest for school readiness screening and as outcome variables in intervention research aimed at improving those skills in order to facilitate learning. The objective of this study was to identify…

  13. Generation of Requirements for Simulant Measurements. Revised, May 30, 2010

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Edmunson, Jennifer

    2010-01-01

    This document provides a formal, logical explanation of the parameters selected for the Figure of Merit algorithm used to evaluate lunar regolith simulant. The objectives, requirements, assumptions and analysis behind the parameters is provided. From NASA's objectives for lunar simulants a requirement is derived to verify and validate simulant performance versus lunar regolith. This requirement leads to a specification that comparative measurements be taken the same way on the regolith and the simulant. In turn this leads to a set of 9 criteria with which to evaluate comparative measurement. Many of the potential measurements of interest are not defensible under these criteria, for example many geotechnical properties of interest were not explicitly measured during Apollo and they can only be measured in situ on the Moon. A 2005 workshop identified 32 properties of major interest to users (Sibille Carpenter Schlagheck, and French, 2006). Virtually all of the properties are tightly constrained, though not predictable, if just four parameters are controlled. Three: composition, size and shape, are recognized as being definable at the particle level. The fourth, density, is a bulk property. In recent work a fifth parameter has been identified, which will need to be added to future releases of the Figure of Merit: spectroscopy.

  14. Generation of Requirements for Simulant Measurements

    NASA Technical Reports Server (NTRS)

    Rickman, D. L.; Schrader, C. M.; Edmunson, J. E.

    2010-01-01

    This TM presents a formal, logical explanation of the parameters selected for the figure of merit (FoM) algorithm. The FoM algorithm is used to evaluate lunar regolith simulant. The objectives, requirements, assumptions, and analysis behind the parameters are provided. A requirement is derived to verify and validate simulant performance versus lunar regolith from NASA s objectives for lunar simulants. This requirement leads to a specification that comparative measurements be taken the same way on the regolith and the simulant. In turn, this leads to a set of nine criteria with which to evaluate comparative measurements. Many of the potential measurements of interest are not defensible under these criteria. For example, many geotechnical properties of interest were not explicitly measured during Apollo and they can only be measured in situ on the Moon. A 2005 workshop identified 32 properties of major interest to users. Virtually all of the properties are tightly constrained, though not predictable, if just four parameters are controlled. Three parameters (composition, size, and shape) are recognized as being definable at the particle level. The fourth parameter (density) is a bulk property. In recent work, a fifth parameter (spectroscopy) has been identified, which will need to be added to future releases of the FoM.

  15. Extracting contours of oval-shaped objects by Hough transform and minimal path algorithms

    NASA Astrophysics Data System (ADS)

    Tleis, Mohamed; Verbeek, Fons J.

    2014-04-01

    Circular and oval-like objects are very common in cell and micro biology. These objects need to be analyzed, and to that end, digitized images from the microscope are used so as to come to an automated analysis pipeline. It is essential to detect all the objects in an image as well as to extract the exact contour of each individual object. In this manner it becomes possible to perform measurements on these objects, i.e. shape and texture features. Our measurement objective is achieved by probing contour detection through dynamic programming. In this paper we describe a method that uses Hough transform and two minimal path algorithms to detect contours of (ovoid-like) objects. These algorithms are based on an existing grey-weighted distance transform and a new algorithm to extract the circular shortest path in an image. The methods are tested on an artificial dataset of a 1000 images, with an F1-score of 0.972. In a case study with yeast cells, contours from our methods were compared with another solution using Pratt's figure of merit. Results indicate that our methods were more precise based on a comparison with a ground-truth dataset. As far as yeast cells are concerned, the segmentation and measurement results enable, in future work, to retrieve information from different developmental stages of the cell using complex features.

  16. Explaining significant differences in subjective and objective measures of cardiovascular health: evidence for the socioeconomic gradient in a population-based study

    PubMed Central

    2013-01-01

    Background To assess prevalence rates of subjective and objective reports of two cardiovascular disorders (hypertension and hypercholesterolemia) for the same subset of respondents in a large-scale study. To determine whether and the extent to which the socioeconomic health gradient differed in the subjective and objective reports of the two cardiovascular disorders. Methods Data from the first wave (2009/2011) of The Irish Longitudinal Study on Ageing were used (n = 4,179). This is a nationally representative study of community-dwelling adults aged 50+ residing in Ireland. Subjective measures were derived from self-reports of doctor-diagnosed hypertension and high cholesterol. Objective measure of hypertension was defined as: systolic blood pressure ≥140 mm Hg and/or diastolic blood pressure ≥90 mm Hg and/or on antihypertensive medication. Objective measure of hypercholesterolemia was defined as: total cholesterol ≥5.2 mmol/L and/or on cholesterol-lowering medication. Objective measures of low-density-lipoprotein cholesterol and high-density-lipoprotein cholesterol were also used. Two measures of socioeconomic gradient were employed: education and wealth. Binary and multinomial logistic and linear regression analyses were used. Analyses were adjusted for an extensive battery of covariates, including demographics and measures of physical/behavioural health and health care utilization. Results Prevalence of cardiovascular disorders: prevalence of hypertension and hypercholesterolemia was significantly higher when the cardiovascular disorders were measured objectively as compared to self-reports (64% and 72.1% versus 37% and 41.1%, respectively). Socioeconomic gradient in hypertension: the odds of being objectively hypertensive were significantly lower for individuals with tertiary/higher education (OR, 0.74; 95% CI, 0.60-0.92) and in the highest tertile of the wealth distribution (OR, 0.77; 95% CI, 0.62-0.95). In contrast, the associations between socioeconomic status and self-reported hypertension were not statistically significant. Socioeconomic gradient in hypercholesterolemia: wealthier individuals had higher odds of self-reporting elevated cholesterol (OR, 1.28; 95% CI, 1.03-1.58). Associations between socioeconomic status and objectively measured hypercholesterolemia and low-density-lipoprotein cholesterol were not significant. Higher education and, to a lesser extent, greater wealth were associated with higher levels of high-density-lipoprotein cholesterol. Conclusions Clear discrepancies in prevalence rates and gradients by socioeconomic status were found between subjective and objective reports of both disorders. This emphasizes the importance of objective measures when collecting population data. PMID:24119371

  17. Systems and Methods for Locating a Target in a GPS-Denied Environment

    NASA Technical Reports Server (NTRS)

    Mackay, John D. (Inventor); Murdock, Ronald G. (Inventor); Cummins, Douglas A. (Inventor)

    2017-01-01

    A system for locating an object in a GPS-denied environment includes first and second stationary nodes of a network and an object out of synchronization with a common time base of the network. The system includes one or more processors that are configured to estimate distances between the first stationary node and the object and a distance between the second stationary node and the object by comparing time-stamps of messages relayed between the object and the nodes. A position of the object can then be trilaterated using a location of each of the first and second stationary nodes and the measured distances between the object and each of the first and second stationary nodes.

  18. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed Central

    Hastings, Gareth D.; Marsack, Jason D.; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A.

    2017-01-01

    Purpose To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Methods Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. Results For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ±SD was −0.06 ±0.04 with both refractions; dilated was −0.05 ±0.04 with the objective, and −0.05 ±0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. Conclusions A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. PMID:28370389

  19. Information Filtering via Clustering Coefficients of User-Object Bipartite Networks

    NASA Astrophysics Data System (ADS)

    Guo, Qiang; Leng, Rui; Shi, Kerui; Liu, Jian-Guo

    The clustering coefficient of user-object bipartite networks is presented to evaluate the overlap percentage of neighbors rating lists, which could be used to measure interest correlations among neighbor sets. The collaborative filtering (CF) information filtering algorithm evaluates a given user's interests in terms of his/her friends' opinions, which has become one of the most successful technologies for recommender systems. In this paper, different from the object clustering coefficient, users' clustering coefficients of user-object bipartite networks are introduced to improve the user similarity measurement. Numerical results for MovieLens and Netflix data sets show that users' clustering effects could enhance the algorithm performance. For MovieLens data set, the algorithmic accuracy, measured by the average ranking score, can be improved by 12.0% and the diversity could be improved by 18.2% and reach 0.649 when the recommendation list equals to 50. For Netflix data set, the accuracy could be improved by 14.5% at the optimal case and the popularity could be reduced by 13.4% comparing with the standard CF algorithm. Finally, we investigate the sparsity effect on the performance. This work indicates the user clustering coefficients is an effective factor to measure the user similarity, meanwhile statistical properties of user-object bipartite networks should be investigated to estimate users' tastes.

  20. A comparison of effects from prescribed fires and wildfires managed for resource objectives in Sequoia and Kings Canyon National Parks

    USGS Publications Warehouse

    Nesmith, C.B.; Caprio, Anthony C.; Pfaff, Anne H.; McGinnis, Thomas W.; Keeley, Jon E.

    2011-01-01

    Current goals for prescription burning are focused on measures of fuel consumption and changes in forest density. These benchmarks, however, do not address the extent to which prescription burning meets perceived ecosystem needs of heterogeneity in burning, both for overstory trees and understory herbs and shrubs. There are still questions about how closely prescribed fires mimic these patterns compared to natural wildfires. This study compared burn patterns of prescribed fires and managed unplanned wildfires to understand how the differing burning regimes affect ecosystem properties. Measures of forest structure and fire severity were sampled in three recent prescribed fires and three wildfires managed for resource objectives in Sequoia and Kings Canyon National Parks. Fine scale patterns of fire severity and heterogeneity were compared between fire types using ground-based measures of fire effects on fuels and overstory and understory vegetation. Prescribed fires and wildfires managed for resource objectives displayed similar patterns of overstory and understory fire severity, heterogeneity, and seedling and sapling survival. Variation among plots within the same fire was always greater than between fire types. Prescribed fires can provide burned landscapes that approximate natural fires in many ways. It is recognized that constraints placed on when wildfires managed for resource objectives are allowed to burn freely may bias the range of conditions that might have been experienced under more natural conditions. Therefore they may not exactly mimic natural wildfires. Overall, the similarity in fire effects that we observed between prescribed fires and managed wildfires indicate that despite the restrictions that are often placed on prescribed fires, they appear to be creating post-fire conditions that approximate natural fires when assessed on a fine spatial scale.

  1. Dual-wavelength digital holographic imaging with phase background subtraction

    NASA Astrophysics Data System (ADS)

    Khmaladze, Alexander; Matz, Rebecca L.; Jasensky, Joshua; Seeley, Emily; Holl, Mark M. Banaszak; Chen, Zhan

    2012-05-01

    Three-dimensional digital holographic microscopic phase imaging of objects that are thicker than the wavelength of the imaging light is ambiguous and results in phase wrapping. In recent years, several unwrapping methods that employed two or more wavelengths were introduced. These methods compare the phase information obtained from each of the wavelengths and extend the range of unambiguous height measurements. A straightforward dual-wavelength phase imaging method is presented which allows for a flexible tradeoff between the maximum height of the sample and the amount of noise the method can tolerate. For highly accurate phase measurements, phase unwrapping of objects with heights higher than the beat (synthetic) wavelength (i.e. the product of the original two wavelengths divided by their difference), can be achieved. Consequently, three-dimensional measurements of a wide variety of biological systems and microstructures become technically feasible. Additionally, an effective method of removing phase background curvature based on slowly varying polynomial fitting is proposed. This method allows accurate volume measurements of several small objects with the same image frame.

  2. Assessment of neutron dosemeters around standard sources and nuclear fissile objects.

    PubMed

    Raimondi, N; Tournier, B; Groetz, J E; Piot, J; Riebler, E; Crovisier, P; Chambaudet, A; Cabanné, N

    2002-01-01

    In order to evaluate the neutron doses around nuclear fissile objects, a comparative study has been made on several neutron dosemeters: bubble dosemeters, etched-track detectors (CR-39) and 3He-filled proportional counters used as dose-rate meters. The measurements were made on the ambient and the personal dose equivalents H*(10) and Hp(10). Results showed that several bubble dosemeters should have been used due to a low reproducibility in the measurements. A strong correlation with the neutron energy was also found, with about a 30% underestimation of Hp(10) for neutrons from the PuBe source, and about a 9% overestimation for neutrons from the 252Cf source. Measurements of the nuclear fissile objects were made using the CR-39 and the dose-rate meters. The CR-39 led to an underestimation of 30% with respect to the neutron dose-rate meter measurements. In addition, the MCNP calculation code was used in the different configurations.

  3. Tissue tonometry is a simple, objective measure for pliability of burn scar: is it reliable?

    PubMed

    Lye, Ian; Edgar, Dale W; Wood, Fiona M; Carroll, Sara

    2006-01-01

    Objective measurement of burn scar response to treatment is important to facilitate individual patient care, research, and service development. This work examines the validity and reliability of the tonometer as a means of quantifying scar pliability. Ten burn survivors were recruited into the study. Triplicate measures were taken for each of four scar and one normal skin point. The pliability score from the Vancouver Scar Scale also was used as a comparison. The tonometer demonstrated a high degree of reliability (intraclass correlation coefficients 0.91-0.94). It also was shown to provide a valid measure of pliability by quantifying decreased tissue deformation for scar (2.04 +/- 0.45 mm) compared with normal tissue (3.02 +/- 0.92 mm; t = 4.28, P = .004) and a moderate correlation with Vancouver Scar Scale scores. The tissue tonometer provides a repeatable, objective index of burn scar pliability. Using the methods described, it is a simple, clinically useful technique for monitoring an individual's scar.

  4. An objective long-term evaluation of Integra (a dermal skin substitute) and split thickness skin grafts, in acute burns and reconstructive surgery.

    PubMed

    Nguyen, Dai Q A; Potokar, Tom S; Price, Patricia

    2010-02-01

    The field of wound healing and tissue repair has advanced rapidly in the last decade, with this there is an increasing emphasis on the importance of the functional and cosmetic outcomes following injury. Integra artificial skin is the most widely used synthetic skin substitute and is reported to have better outcomes in relation to the appearance and elasticity when compared to split thickness skin grafting (SSG). A review of the literature reveals very few trials that are based on an objective evaluation of Integra treated scars as compared to SSGs. This research aimed to provide objective data on the long-term outcome of Integra. All adult patients from the Welsh Burns Centre who had been successfully treated with Integra+/-SSG were invited to attend a clinic for a follow up provided they had been healed for greater than one year. The hypothesis that Integra scars are more pliable than skin grafts was tested objectively using the Cutometer, a suction device which measures skin elasticity. Of the 13 patients eligible, six were available for assessment. The results of this study suggest that Integra treated sites correlate well with normal skin as measured by the Cutometer. This was statistically significant for the parameters Ur/Ue (elastic function) and Ur/Uf (gross elasticity). On the other hand there was no correlation seen between the patients SSG sites and the patient's normal skin. With advances in medicine we are increasingly able to modulate wound healing and the resultant scars. In order to assess new and often costly treatments the need for objective scar measurement tools have become apparent. Integra has been advocated to improve scarring from injury. However, there have been few studies to evaluate the long-term outcome of Integra as compared to traditional methods such as SSG. In the past scar evaluation has been based on subjective scores by patients and clinicians. Now the mechanical properties of the skin can be evaluated using simple bioengineering methods such as the Cutometer Suction Device. Using this device our study has objectively demonstrated that the elastic properties of areas treated with Integra is comparable to normal skin. Copyright (c) 2009 Elsevier Ltd and ISBI. All rights reserved.

  5. Fatigue and Sleep Among Employees With Prospective Increase in Work Time Control: A 1-Year Observational Study With Objective Assessment.

    PubMed

    Kubo, Tomohide; Takahashi, Masaya; Liu, Xinxin; Ikeda, Hiroki; Togo, Fumiharu; Shimazu, Akihito; Tanaka, Katsutoshi; Kamata, Naoki; Kubo, Yoshiko; Uesugi, Junko

    2016-11-01

    This observational study aimed to determine how 1-year changes in work time control (WTC) have an impact upon objectively measured fatigue and sleep among employees. Thirty-nine employees were divided into two groups according to whether or not their WTC increased from baseline to 1 year later. Psychomotor vigilance task (PVT) and wrist actigraphy were used to objectively measure fatigue and sleep, respectively. Self-reported outcomes were also measured. The increased WTC group showed gradual improvements in PVT performance and sleep quality over the course of the follow-up period compared with the not-increased WTC group. Between-group differences were statistically significant for PVT lapses and tended to be significant for PVT speed after 1 year. A progressive increase in WTC could play a crucial role in reducing fatigue and promoting sleep among employees.

  6. Comparison of Pitch Strength With Perceptual and Other Acoustic Metric Outcome Measures Following Medialization Laryngoplasty.

    PubMed

    Rubin, Adam D; Jackson-Menaldi, Cristina; Kopf, Lisa M; Marks, Katherine; Skeffington, Jean; Skowronski, Mark D; Shrivastav, Rahul; Hunter, Eric J

    2018-05-14

    The diagnoses of voice disorders, as well as treatment outcomes, are often tracked using visual (eg, stroboscopic images), auditory (eg, perceptual ratings), objective (eg, from acoustic or aerodynamic signals), and patient report (eg, Voice Handicap Index and Voice-Related Quality of Life) measures. However, many of these measures are known to have low to moderate sensitivity and specificity for detecting changes in vocal characteristics, including vocal quality. The objective of this study was to compare changes in estimated pitch strength (PS) with other conventionally used acoustic measures based on the cepstral peak prominence (smoothed cepstral peak prominence, cepstral spectral index of dysphonia, and acoustic voice quality index), and clinical judgments of voice quality (GRBAS [grade, roughness, breathiness, asthenia, strain] scale) following laryngeal framework surgery. This study involved post hoc analysis of recordings from 22 patients pretreatment and post treatment (thyroplasty and behavioral therapy). Sustained vowels and connected speech were analyzed using objective measures (PS, smoothed cepstral peak prominence, cepstral spectral index of dysphonia, and acoustic voice quality index), and these results were compared with mean auditory-perceptual ratings by expert clinicians using the GRBAS scale. All four acoustic measures changed significantly in the direction that usually indicates improved voice quality following treatment (P < 0.005). Grade and breathiness correlated the strongest with the acoustic measures (|r| ~0.7) with strain being the least correlated. Acoustic analysis on running speech highly correlates with judged ratings. PS is a robust, easily obtained acoustic measure of voice quality that could be useful in the clinical environment to follow treatment of voice disorders. Copyright © 2018. Published by Elsevier Inc.

  7. Towards a formalism for mapping the spacetimes of massive compact objects: Bumpy black holes and their orbits

    NASA Astrophysics Data System (ADS)

    Collins, Nathan A.; Hughes, Scott A.

    2004-06-01

    Astronomical observations have established that extremely compact, massive objects are common in the Universe. It is generally accepted that these objects are, in all likelihood, black holes. As observational technology has improved, it has become possible to test this hypothesis in ever greater detail. In particular, it is or will be possible to measure the properties of orbits deep in the strong field of a black hole candidate (using x-ray timing or future gravitational-wave measurements) and to test whether they have the characteristics of black hole orbits in general relativity. Past work has shown that, in principle, such measurements can be used to map the spacetime of a massive compact object, testing in particular whether the object’s multipolar structure satisfies the rather strict constraints imposed by the black hole hypothesis. Performing such a test in practice requires that we be able to compare against objects with the “wrong” multipole structure. In this paper, we present tools for constructing the spacetimes of bumpy black holes: objects that are almost black holes, but that have some multipoles with the wrong value. In this first analysis, we focus on objects with no angular momentum. Generalization to bumpy Kerr black holes should be straightforward, albeit labor intensive. Our construction has two particularly desirable properties. First, the spacetimes which we present are good deep into the strong field of the object—we do not use a “large r” expansion (except to make contact with weak field intuition). Second, our spacetimes reduce to the exact black hole spacetimes of general relativity in a natural way, by dialing the “bumpiness” of the black hole to zero. We propose that bumpy black holes can be used as the foundation for a null experiment: if black hole candidates are indeed the black holes of general relativity, their bumpiness should be zero. By comparing the properties of orbits in a bumpy spacetime with those measured from an astrophysical source, observations should be able to test this hypothesis, stringently testing whether they are in fact the black holes of general relativity.

  8. Improving educational objectives of the Industrial and Management Systems Engineering programme at Kuwait University

    NASA Astrophysics Data System (ADS)

    Aldowaisan, Tariq; Allahverdi, Ali

    2016-05-01

    This paper describes the process of developing programme educational objectives (PEOs) for the Industrial and Management Systems Engineering programme at Kuwait University, and the process of deployment of these PEOs. Input of the four constituents of the programme, faculty, students, alumni, and employers, is incorporated in the development and update of the PEOs. For each PEO an assessment process is employed where performance measures are defined along with target attainment levels. Results from assessment tools are compared with the target attainment levels to measure performance with regard to the PEOs. The assessment indicates that the results meet or exceed the target attainment levels of the PEOs' performance measures.

  9. Subjective vs Objective Accommodative Amplitude: Preschool to Presbyopia

    PubMed Central

    Anderson, Heather A.; Stuebing, Karla K.

    2014-01-01

    Purpose This study compared subjective and objective accommodative amplitudes to characterize changes from preschool to presbyopia. Methods Monocular accommodative amplitude was measured with three techniques in random order (subjective push-up, objective minus lens stimulated, and objective proximal stimulated) on 236 subjects 3–64 years using a 1.5mm letter. Subjective push-up amplitudes were the dioptric distance at which the target first blurred along a near-point rod. Objective minus lens stimulated amplitudes were the greatest accommodative response obtained by Grand Seiko autorefraction as subjects viewed the stimulus at 33cm through increasing minus lens powers. Objective proximal stimulated amplitudes were the greatest accommodative response obtained by Grand Seiko autorefraction as subjects viewed the stimulus at increasing proximity from 40cm up to 3.33cm. Results In comparison with subjective push-up amplitudes, objective amplitudes were lower at all ages, with the most dramatic difference occurring in the 3–5 year group (subjective push-up = 16.00 ± 4.98D versus objective proximal stimulated = 7.94 ± 2.37D and objective lens stimulated = 6.20 ± 1.99D). Objective proximal and lens stimulated amplitudes were largest in the 6–10 year group (8.81 ± 1.24D and 8.05 ± 1.82D, respectively) and gradually decreased until the fourth decade of life when a rapid decline to presbyopia occurred. There was a significant linear relationship between objective techniques (y = 0.74 + 0.96x, R2 = 0.85, p<0.001) with greater amplitudes measured for the proximal stimulated technique (mean difference = 0.55D). Conclusions Objective measurements of accommodation demonstrate that accommodative amplitude is substantially less than that measured by the subjective push-up technique, particularly in young children. These findings have important clinical implications for the management of uncorrected hyperopia. PMID:25602235

  10. Measuring Compliance with Tobacco-Free Campus Policy

    ERIC Educational Resources Information Center

    Fallin, Amanda; Murrey, Megan; Johnson, Andrew O.; Riker, Carol A.; Rayens, Mary Kay; Hahn, Ellen J.

    2012-01-01

    Objective: The purpose is to describe psychometric testing and feasibility of the Tobacco-Free Compliance Assessment Tool (TF-CAT) to measure tobacco-free policy compliance at a public university and medical center. The aims are to (1) investigate concurrent validity by comparing the number of cigarette butts in areas covered by the policy with…

  11. SOIL RESPIRATION RESPONSE TO THREE YEARS OF ELEVATED CO-2 AND N FERTILIZATION IN PONDEROSA PINE (PINUS PONDEROSA DOUG. EX LAWS.)

    EPA Science Inventory

    We measured growing season soil CO-2 evolution under elevated atmospheric (CO-2) and soil nitrogen (N) additions. Our objectives were to determine treatment effects, quantify seasonal variation, and compare two measurement techniques. Elevated (CO-2) treatments were applied in op...

  12. Large Capacitance Measurement by Multiple Uses of MBL Charge Sensor

    ERIC Educational Resources Information Center

    Lee, Jung Sook; Chae, Min; Kim, Jung Bog

    2010-01-01

    A recent article by Morse described interesting electrostatics experiments using an MBL charge sensor. In this application, the charge sensor has a large capacitance compared to the charged test object, so nearly all charges can be transferred to the sensor capacitor from the capacitor to be measured. However, the typical capacitance of commercial…

  13. Kinematic Measures of Imitation Fidelity in Primary School Children

    ERIC Educational Resources Information Center

    Williams, Justin H. G.; Casey, Jackie M.; Braadbaart, Lieke; Culmer, Peter R.; Mon-Williams, Mark

    2014-01-01

    We sought to develop a method for measuring imitation accuracy objectively in primary school children. Children imitated a model drawing shapes on the same computer-tablet interface they saw used in video clips, allowing kinematics of model and observers' actions to be directly compared. Imitation accuracy was reported as a correlation reflecting…

  14. Quantitative endoscopy: initial accuracy measurements.

    PubMed

    Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P

    2000-02-01

    The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.

  15. Cardiac output and systemic vascular resistance: Clinical assessment compared with a noninvasive objective measurement in children with shock.

    PubMed

    Razavi, Asma; Newth, Christopher J L; Khemani, Robinder G; Beltramo, Fernando; Ross, Patrick A

    2017-06-01

    To evaluate physician assessment of cardiac output and systemic vascular resistance in patients with shock compared with an ultrasonic cardiac output monitor (USCOM). To explore potential changes in therapy decisions if USCOM data were available using physician intervention answers. Double-blinded, prospective, observational study in a tertiary hospital pediatric intensive care unit. Forty children (<18years) admitted with shock, requiring ongoing volume resuscitation or inotropic support. Two to 3 physicians clinically assessed cardiac output and systemic vascular resistance, categorizing them as high, normal, or low. An investigator simultaneously measured cardiac index (CI) and systemic vascular resistance index (SVRI) with USCOM categorized as high, normal, or low. Overall agreement between physician and USCOM for CI (48.5% [κ = 0.18]) and SVRI (45.9% [κ = 0.16]) was poor. Interobserver agreement was also poor for CI (58.7% [κ = 0.33]) and SVRI (52.3% [κ = 0.28]). Comparing theoretical physician interventions to "acceptable" or "unacceptable" clinical interventions, based on USCOM measurement, 56 (21%) physician interventions were found to be "unacceptable." There is poor agreement between physician-assessed CI and SVRI and USCOM, with significant interobserver variability among physicians. Objective measurement of CI and SVRI may reduce variability and improve diagnostic accuracy. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Structural Analysis of Character Education: A Crosscultural Investigation

    ERIC Educational Resources Information Center

    Sivo, Stephen; Karl, Shannon; Fox, Jesse; Taub, Gordon; Robinson, Edward

    2017-01-01

    The primary objective of this cross-cultural investigation is to compare patterns in student responses to an empirically scrutinized character education measure administered to students in four school districts in Florida with students in a school in Kenya. In this way, the generalizability of findings for scale scores could be compared across…

  17. Stress Levels of Agricultural Science Cooperating Teachers and Student Teachers: A Repeated Measures Comparative Assessment

    ERIC Educational Resources Information Center

    McKim, Billy R.; Rayfield, John; Harlin, Julie; Adams, Andy

    2013-01-01

    This study compared job stress levels of Texas agricultural science cooperating teachers and Texas agricultural science student teachers across a semester. The research objectives included describing secondary agricultural science cooperating teachers and student teachers perceptions of stressors, by time of semester (beginning, middle, and end),…

  18. Optical Photometric Observations of GEO Debris

    NASA Technical Reports Server (NTRS)

    Seitzer, Patrick; Rodriquez-Cowardin, Heather M.; Barker, Edwin S.; Abercromby, Kira J.; Kelecy, Thomas M.; Horstman, Matt

    2010-01-01

    We report on a continuing program of optical photometric measurements of faint orbital debris at geosynchronous Earth orbit (GEO). These observations can be compared with laboratory studies of actual spacecraft materials in an effort to determine what the faint debris at GEO may be. We have optical observations from Cerro Tololo Inter-American Observatory (CTIO) in Chile of two samples of debris: 1. GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Curtis-Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the CTIO/SMARTS 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R = 15 t11 magnitude that are discovered in the MODEST survey. 2. A smaller sample of high area to mass ratio (AMR) objects discovered independently, and acquired using predictions from orbits derived from independent tracking data collected days prior to the observations. Our optical observations in standard astronomical BVRI filters are done with either telescope, and with the telescope tracking the debris object at the object's angular rate. Observations in different filters are obtained sequentially. We have obtained 71 calibrated sequences of R-B-V-I-R magnitudes. A total of 66 of these sequences have 3 or more good measurements in all filters (not contaminated by star streaks or in Earth's shadow). Most of these sequences show brightness variations, but a small subset has observed brightness variations consistent with that expected from observational errors alone. The majority of these stable objects are redder than a solar color in both B-R and R-I. There is no dependence on color with brightness. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and duration of observations are the same to better than 50 milliseconds. Thus, the B-R color is a true measure of the surface of the debris piece facing the telescopes for that observation. Any change in color reflects a real change in the debris surface. We will compare our observations with models and laboratory measurements of selected surfaces.

  19. On the three-quarter view advantage of familiar object recognition.

    PubMed

    Nonose, Kohei; Niimi, Ryosuke; Yokosawa, Kazuhiko

    2016-11-01

    A three-quarter view, i.e., an oblique view, of familiar objects often leads to a higher subjective goodness rating when compared with other orientations. What is the source of the high goodness for oblique views? First, we confirmed that object recognition performance was also best for oblique views around 30° view, even when the foreshortening disadvantage of front- and side-views was minimized (Experiments 1 and 2). In Experiment 3, we measured subjective ratings of view goodness and two possible determinants of view goodness: familiarity of view, and subjective impression of three-dimensionality. Three-dimensionality was measured as the subjective saliency of visual depth information. The oblique views were rated best, most familiar, and as approximating greatest three-dimensionality on average; however, the cluster analyses showed that the "best" orientation systematically varied among objects. We found three clusters of objects: front-preferred objects, oblique-preferred objects, and side-preferred objects. Interestingly, recognition performance and the three-dimensionality rating were higher for oblique views irrespective of the clusters. It appears that recognition efficiency is not the major source of the three-quarter view advantage. There are multiple determinants and variability among objects. This study suggests that the classical idea that a canonical view has a unique advantage in object perception requires further discussion.

  20. Perceived object stability depends on multisensory estimates of gravity.

    PubMed

    Barnett-Cowan, Michael; Fleming, Roland W; Singh, Manish; Bülthoff, Heinrich H

    2011-04-27

    How does the brain estimate object stability? Objects fall over when the gravity-projected centre-of-mass lies outside the point or area of support. To estimate an object's stability visually, the brain must integrate information across the shape and compare its orientation to gravity. When observers lie on their sides, gravity is perceived as tilted toward body orientation, consistent with a representation of gravity derived from multisensory information. We exploited this to test whether vestibular and kinesthetic information affect this visual task or whether the brain estimates object stability solely from visual information. In three body orientations, participants viewed images of objects close to a table edge. We measured the critical angle at which each object appeared equally likely to fall over or right itself. Perceived gravity was measured using the subjective visual vertical. The results show that the perceived critical angle was significantly biased in the same direction as the subjective visual vertical (i.e., towards the multisensory estimate of gravity). Our results rule out a general explanation that the brain depends solely on visual heuristics and assumptions about object stability. Instead, they suggest that multisensory estimates of gravity govern the perceived stability of objects, resulting in objects appearing more stable than they are when the head is tilted in the same direction in which they fall.

  1. Effect of Two Isolated Vocal-facilitating Techniques Chant Talk and Pitch Inflections on the Phonation of Female Speech-language Pathology Students: A Pilot Study.

    PubMed

    Meerschman, Iris; Bettens, Kim; Dejagere, Stefanie; Tetaert, Lieselot; D'haeseleer, Evelien; Claeys, Sofie; Van Lierde, Kristiane

    2016-11-01

    The purpose of this study was to determine the effect of the isolated vocal-facilitating techniques Chant Talk and Pitch Inflections on the phonation of healthy female speech-language pathology (SLP) students. A multigroup pretest-posttest design was used. A homogenous group of 40 healthy female SLP students with a mean age of 18.7 years were randomly assigned into 3 groups: a Chant Talk group (practicing Chant Talk across 18 weeks), a Pitch Inflections group (practicing Pitch Inflections across 18 weeks), and a control group (practicing no facilitating techniques). To compare vocal measures before and after this time span, an identical objective voice assessment protocol (aerodynamic measurement, acoustic analysis, voice range profile, and Dysphonia Severity Index) was performed in the 3 groups. Both Chant Talk and Pitch Inflections groups resulted in a significant decrease of the acoustic measure noise-to-harmonics ratio compared with the control group. The Chant Talk group resulted in a significant increase in the acoustic measure fundamental frequency compared with the control group. The results of this pilot study suggest that the facilitating techniques Chant Talk and Pitch Inflections may improve the objective measure of breathiness (noise-to-harmonics ratio) in healthy female SLP students. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Tracking Success: Outputs Versus Outcomes-A Comparison of Accredited and Non-Accredited Public Health Agencies' Community Health Improvement Plan objectives.

    PubMed

    Perrault, Evan K; Inderstrodt-Stephens, Jill; Hintz, Elizabeth A

    2018-06-01

    With funding for public health initiatives declining, creating measurable objectives that are focused on tracking and changing population outcomes (i.e., knowledge, attitudes, or behaviors), instead of those that are focused on health agencies' own outputs (e.g., promoting services, developing communication messages) have seen a renewed focus. This study analyzed 4094 objectives from the Community Health Improvement Plans (CHIPs) of 280 local PHAB-accredited and non-accredited public health agencies across the United States. Results revealed that accredited agencies were no more successful at creating outcomes-focused objectives (35% of those coded) compared to non-accredited agencies (33% of those coded; Z = 1.35, p = .18). The majority of objectives were focused on outputs (accredited: 61.2%; non-accredited: 63.3%; Z = 0.72, p = .47). Outcomes-focused objectives primarily sought to change behaviors (accredited: 85.43%; non-accredited: 80.6%), followed by changes in knowledge (accredited: 9.75%; non-accredited: 10.8%) and attitudes (accredited: 1.6%; non-accredited: 5.1%). Non-accredited agencies had more double-barreled objectives (49.9%) compared to accredited agencies (32%; Z = 11.43, p < .001). The authors recommend that accreditation procedures place a renewed focus on ensuring that public health agencies strive to achieve outcomes. It is also advocated that public health agencies work with interdisciplinary teams of Health Communicators who can help them develop procedures to effectively and efficiently measure outcomes of knowledge and attitudes that are influential drivers of behavioral changes.

  3. Evaluating the Information Content of Newly Retrieved SAGEII NO2 Measurements in the Lower Stratosphere

    NASA Technical Reports Server (NTRS)

    Newchurch, Michael J.; Cunnold, Derek M.; Zawodny, Joseph M.

    2000-01-01

    The objective of this research project is: to calculate ozone trends in the stratosphere from Dobson Umkehr measurements, to determine the vertical profile of trends at Arosa by using a sophisticated statistical model (MARCH) to separate solar, aerosol, and QBO effects on Dobson Umkehr measurements, and to compare Umkehr trends with SBUV and SAGE I/II trends in the stratosphere.

  4. Examination of Relationship Between Photonic Signatures and Fracture Strength of Fused Silica Used in Orbiter Windows

    NASA Technical Reports Server (NTRS)

    Yost, William T.; Cramer, K. Elliott; Estes, Linda R.; Salem, Jonathan A.; Lankford, James, Jr.; Lesniak, Jon

    2011-01-01

    A commercially available grey-field polariscope (GFP) instrument for photoelastic examination is used to assess impact damage inflicted upon the outermost pane of the orbiter windows. Four categories of damage: hyper-velocity impacts that occur during space-flight (HVI); hypervelocity impacts artificially made at the Hypervelocity Impact Technology Facility (HIT-F); impacts made by larger objects falling onto the pane surface to simulate dropped items on the window during service/storage of vehicle (Bruises); and light scratches from dull objects designed to mimic those that might occur by dragging a dull object across the glass surface (Chatter Checks) are examined. The damage sites are cored from fused silica window carcasses, examined with the GFP and other methodologies, and broken using the ASTM Standard C1499-09 to measure the fracture strength. A correlation is made between the fracture strength and damage-site measurements including geometrical measurements and GFP measurements of photoelastic retardation (stress patterns) surrounding the damage sites. An analytical damage model to predict fracture strength from photoelastic retardation measurements is presented and compared with experimental results.

  5. Histogram Curve Matching Approaches for Object-based Image Classification of Land Cover and Land Use

    PubMed Central

    Toure, Sory I.; Stow, Douglas A.; Weeks, John R.; Kumar, Sunil

    2013-01-01

    The classification of image-objects is usually done using parametric statistical measures of central tendency and/or dispersion (e.g., mean or standard deviation). The objectives of this study were to analyze digital number histograms of image objects and evaluate classifications measures exploiting characteristic signatures of such histograms. Two histograms matching classifiers were evaluated and compared to the standard nearest neighbor to mean classifier. An ADS40 airborne multispectral image of San Diego, California was used for assessing the utility of curve matching classifiers in a geographic object-based image analysis (GEOBIA) approach. The classifications were performed with data sets having 0.5 m, 2.5 m, and 5 m spatial resolutions. Results show that histograms are reliable features for characterizing classes. Also, both histogram matching classifiers consistently performed better than the one based on the standard nearest neighbor to mean rule. The highest classification accuracies were produced with images having 2.5 m spatial resolution. PMID:24403648

  6. Urban Latino Families' Food Built Environment and Young Children's Produce Consumption.

    PubMed

    Mathieu, Ne P; Sommer, Evan C; Mitchell, Stephanie J; Barkin, Shari L

    2016-01-01

    This study explored the association between objective and subjective ratings of the food environment and child produce consumption for Latino preschoolers at-risk for obesity. Parental surveys (N = 115) assessed perceptions of food availability, affordability, and acceptability. Comparable factors were objectively rated by a trained observer, using the Nutrition Environment Measures Survey for Stores (NEMS-S), in commonly frequented grocery stores cited by participants. There were no significant correlations between objective and subjective measures of food availability, affordability, and acceptability. Greater household income was associated with higher participant perceptions of food acceptability (r = .33, p = .003) and affordability (r = .22, p = .04). Participant-perceived affordability of food was correlated with more frequent child fruit and vegetable consumption (r = .21, p = .03). These findings support that parental subjective ratings of the food environment affects their child's eating behaviors more than objective ratings.

  7. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    PubMed

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  8. Comparison of Methods for Evaluating Urban Transportation Alternatives

    DOT National Transportation Integrated Search

    1975-02-01

    The objective of the report was to compare five alternative methods for evaluating urban transportation improvement options: unaided judgmental evaluation cost-benefit analysis, cost-effectiveness analysis based on a single measure of effectiveness, ...

  9. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    NASA Astrophysics Data System (ADS)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  10. MCNP6 simulation of radiographs generated from megaelectron volt X-rays for characterizing a computed tomography system

    NASA Astrophysics Data System (ADS)

    Dooraghi, Alex A.; Tringe, Joseph W.

    2018-04-01

    To evaluate conventional munition, we simulated an x-ray computed tomography (CT) system for generating radiographs from nominal x-ray energies of 6 or 9 megaelectron volts (MeV). CT simulations, informed by measured data, allow for optimization of both system design and acquisition techniques necessary to enhance image quality. MCNP6 radiographic simulation tools were used to model ideal detector responses (DR) that assume either (1) a detector response proportional to photon flux (N) or (2) a detector response proportional to energy flux (E). As scatter may become significant with MeV x-ray systems, simulations were performed with and without the inclusion of object scatter. Simulations were compared against measurements of a cylindrical munition component principally composed of HMX, tungsten and aluminum encased in carbon fiber. Simulations and measurements used a 6 MeV peak energy x-ray spectrum filtered with 3.175 mm of tantalum. A detector response proportional to energy which includes object scatter agrees to within 0.6 % of the measured line integral of the linear attenuation coefficient. Exclusion of scatter increases the difference between measurement and simulation to 5 %. A detector response proportional to photon flux agrees to within 20 % when object scatter is included in the simulation and 27 % when object scatter is excluded.

  11. Comparison of Three Optical Methods for Measuring Model Deformation

    NASA Technical Reports Server (NTRS)

    Burner, A. W.; Fleming, G. A.; Hoppe, J. C.

    2000-01-01

    The objective of this paper is to compare the current state-of-the-art of the following three optical techniques under study by NASA for measuring model deformation in wind tunnels: (1) video photogrammetry, (2) projection moire interferometry, and (3) the commercially available Optotrak system. An objective comparison of these three techniques should enable the selection of the best technique for a particular test undertaken at various NASA facilities. As might be expected, no one technique is best for all applications. The techniques are also not necessarily mutually exclusive and in some cases can be complementary to one another.

  12. A hybrid continuous-wave terahertz imaging system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolganova, Irina N., E-mail: in.dolganova@gmail.com; Zaytsev, Kirill I., E-mail: kirzay@gmail.ru; Metelkina, Anna A.

    2015-11-15

    A hybrid (active-passive mode) terahertz (THz) imaging system and an algorithm for imaging synthesis are proposed to enhance the THz image quality. The concept of image contrast is used to compare active and passive THz imaging. Combining the measurement of the self-emitted radiation of the object with the back-scattered source radiation measurement, it becomes possible to use the THz image to retrieve maximum information about the object. The experimental results confirm the advantages of hybrid THz imaging systems, which can be generalized for a wide range of applications in the material sciences, chemical physics, bio-systems, etc.

  13. Zopiclone as a preoperative night hypnotic: a double-blind comparison with temazepam and placebo.

    PubMed

    Whitehead, C; Sanders, L; Appadurai, I; Power, I; Rosen, M; Robinson, J

    1994-04-01

    We have examined the hypnotic effects of zopiclone 7.5 mg and temazepam 20 mg compared with placebo in a double-blind, randomized, clinical study of 60 patients on the night before operation. Evaluation was both subjective (visual analogue scales and a sleep questionnaire), to measure the quality of sleep, and objective (critical flicker fusion, object recall and paired associates tasks), to measure residual impairment. We found that zopiclone was an effective single-dose hypnotic with similar residual effects to the benzodiazepine and it may therefore provide a suitable alternative to benzodiazepines.

  14. Self-Monitoring of Listening Abilities in Normal-Hearing Children, Normal-Hearing Adults, and Children with Cochlear Implants

    PubMed Central

    Rothpletz, Ann M.; Wightman, Frederic L.; Kistler, Doris J.

    2012-01-01

    Background Self-monitoring has been shown to be an essential skill for various aspects of our lives, including our health, education, and interpersonal relationships. Likewise, the ability to monitor one’s speech reception in noisy environments may be a fundamental skill for communication, particularly for those who are often confronted with challenging listening environments, such as students and children with hearing loss. Purpose The purpose of this project was to determine if normal-hearing children, normal-hearing adults, and children with cochlear implants can monitor their listening ability in noise and recognize when they are not able to perceive spoken messages. Research Design Participants were administered an Objective-Subjective listening task in which their subjective judgments of their ability to understand sentences from the Coordinate Response Measure corpus presented in speech spectrum noise were compared to their objective performance on the same task. Study Sample Participants included 41 normal-hearing children, 35 normal-hearing adults, and 10 children with cochlear implants. Data Collection and Analysis On the Objective-Subjective listening task, the level of the masker noise remained constant at 63 dB SPL, while the level of the target sentences varied over a 12 dB range in a block of trials. Psychometric functions, relating proportion correct (Objective condition) and proportion perceived as intelligible (Subjective condition) to target/masker ratio (T/M), were estimated for each participant. Thresholds were defined as the T/M required to produce 51% correct (Objective condition) and 51% perceived as intelligible (Subjective condition). Discrepancy scores between listeners’ threshold estimates in the Objective and Subjective conditions served as an index of self-monitoring ability. In addition, the normal-hearing children were administered tests of cognitive skills and academic achievement, and results from these measures were compared to findings on the Objective-Subjective listening task. Results Nearly half of the children with normal hearing significantly overestimated their listening in noise ability on the Objective-Subjective listening task, compared to less than 9% of the adults. There was a significant correlation between age and results on the Objective-Subjective task, indicating that the younger children in the sample (age 7–12 yr) tended to overestimate their listening ability more than the adolescents and adults. Among the children with cochlear implants, eight of the 10 participants significantly overestimated their listening ability (as compared to 13 of the 24 normal-hearing children in the same age range). We did not find a significant relationship between results on the Objective-Subjective listening task and performance on the given measures of academic achievement or intelligence. Conclusions Findings from this study suggest that many children with normal hearing and children with cochlear implants often fail to recognize when they encounter conditions in which their listening ability is compromised. These results may have practical implications for classroom learning, particularly for children with hearing loss in mainstream settings. PMID:22436118

  15. In-Situ Assays Using a New Advanced Mathematical Algorithm - 12400

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oginni, B.M.; Bronson, F.L.; Field, M.B.

    2012-07-01

    Current mathematical efficiency modeling software for in-situ counting, such as the commercially available In-Situ Object Calibration Software (ISOCS), typically allows the description of measurement geometries via a list of well-defined templates which describe regular objects, such as boxes, cylinder, or spheres. While for many situations, these regular objects are sufficient to describe the measurement conditions, there are occasions in which a more detailed model is desired. We have developed a new all-purpose geometry template that can extend the flexibility of current ISOCS templates. This new template still utilizes the same advanced mathematical algorithms as current templates, but allows the extensionmore » to a multitude of shapes and objects that can be placed at any location and even combined. In addition, detectors can be placed anywhere and aimed at any location within the measurement scene. Several applications of this algorithm to in-situ waste assay measurements, as well as, validations of this template using Monte Carlo calculations and experimental measurements are studied. Presented in this paper is a new template of the mathematical algorithms for evaluating efficiencies. This new template combines all the advantages of the ISOCS and it allows the use of very complex geometries, it also allows stacking of geometries on one another in the same measurement scene and it allows the detector to be placed anywhere in the measurement scene and pointing in any direction. We have shown that the template compares well with the previous ISOCS software within the limit of convergence of the code, and also compare well with the MCNPX and measured data within the joint uncertainties for the code and the data. The new template agrees with ISOCS to within 1.5% at all energies. It agrees with the MCNPX to within 10% at all energies and it agrees with most geometries within 5%. It finally agrees with measured data to within 10%. This mathematical algorithm can now be used for quickly and accurately evaluating efficiencies for wider range of gamma-ray spectroscopy applications. (authors)« less

  16. Is there a correlation of sonographic measurements of true vocal cords with gender or body mass indices in normal healthy volunteers?

    PubMed

    Bright, Leah; Secko, Michael; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard

    2014-04-01

    Ultrasound is a readily available, non-invasive technique to visualize airway dimensions at the patient's bedside and possibly predict difficult airways before invasively looking; however, it has rarely been used for emergency investigation of the larynx. There is limited literature on the sonographic measurements of true vocal cords in adults and normal parameters must be established before abnormal parameters can be accurately identified. The primary objective of the following study is to identify the normal sonographic values of human true vocal cords in an adult population. A secondary objective is to determine if there is a difference in true vocal cord measurements in people with different body mass indices (BMIs). The third objective was to determine if there was a statistical difference in the measurements for both genders. True vocal cord measurements were obtained in healthy volunteers by ultrasound fellowship trained emergency medicine physicians using a high frequency linear transducer orientated transversely across the anterior surface of the neck at the level of the thyroid cartilage. The width of the true vocal cord was measured perpendicularly to the length of the cord at its mid-portion. This method was duplicated from a previous study to create a standard of measurement acquisition. A total of 38 subjects were enrolled. The study demonstrated no correlation between vocal cord measurements and patient's characteristics of height, weight, or BMI's. When accounting for vocal cord measurements by gender, males had larger BMI's and larger vocal cord measurements compared with females subjects with a statistically significant different in right vocal cord measurements for females compared with male subjects. No correlation was seen between vocal cord measurements and person's BMIs. In the study group of normal volunteers, there was a difference in size between the male and female vocal cord size.

  17. Everyday listening questionnaire: correlation between subjective hearing and objective performance.

    PubMed

    Brendel, Martina; Frohne-Buechner, Carolin; Lesinski-Schiedat, Anke; Lenarz, Thomas; Buechner, Andreas

    2014-01-01

    Clinical experience has demonstrated that speech understanding by cochlear implant (CI) recipients has improved over recent years with the development of new technology. The Everyday Listening Questionnaire 2 (ELQ 2) was designed to collect information regarding the challenges faced by CI recipients in everyday listening. The aim of this study was to compare self-assessment of CI users using ELQ 2 with objective speech recognition measures and to compare results between users of older and newer coding strategies. During their regular clinical review appointments a group of representative adult CI recipients implanted with the Advanced Bionics implant system were asked to complete the questionnaire. The first 100 patients who agreed to participate in this survey were recruited independent of processor generation and speech coding strategy. Correlations between subjectively scored hearing performance in everyday listening situations and objectively measured speech perception abilities were examined relative to the speech coding strategies used. When subjects were grouped by strategy there were significant differences between users of older 'standard' strategies and users of the newer, currently available strategies (HiRes and HiRes 120), especially in the categories of telephone use and music perception. Significant correlations were found between certain subjective ratings and the objective speech perception data in noise. There is a good correlation between subjective and objective data. Users of more recent speech coding strategies tend to have fewer problems in difficult hearing situations.

  18. Enhanced detection and visualization of anomalies in spectral imagery

    NASA Astrophysics Data System (ADS)

    Basener, William F.; Messinger, David W.

    2009-05-01

    Anomaly detection algorithms applied to hyperspectral imagery are able to reliably identify man-made objects from a natural environment based on statistical/geometric likelyhood. The process is more robust than target identification, which requires precise prior knowledge of the object of interest, but has an inherently higher false alarm rate. Standard anomaly detection algorithms measure deviation of pixel spectra from a parametric model (either statistical or linear mixing) estimating the image background. The topological anomaly detector (TAD) creates a fully non-parametric, graph theory-based, topological model of the image background and measures deviation from this background using codensity. In this paper we present a large-scale comparative test of TAD against 80+ targets in four full HYDICE images using the entire canonical target set for generation of ROC curves. TAD will be compared against several statistics-based detectors including local RX and subspace RX. Even a perfect anomaly detection algorithm would have a high practical false alarm rate in most scenes simply because the user/analyst is not interested in every anomalous object. To assist the analyst in identifying and sorting objects of interest, we investigate coloring of the anomalies with principle components projections using statistics computed from the anomalies. This gives a very useful colorization of anomalies in which objects of similar material tend to have the same color, enabling an analyst to quickly sort and identify anomalies of highest interest.

  19. A Comparative Analysis of Three Monocular Passive Ranging Methods on Real Infrared Sequences

    NASA Astrophysics Data System (ADS)

    Bondžulić, Boban P.; Mitrović, Srđan T.; Barbarić, Žarko P.; Andrić, Milenko S.

    2013-09-01

    Three monocular passive ranging methods are analyzed and tested on the real infrared sequences. The first method exploits scale changes of an object in successive frames, while other two use Beer-Lambert's Law. Ranging methods are evaluated by comparing with simultaneously obtained reference data at the test site. Research is addressed on scenarios where multiple sensor views or active measurements are not possible. The results show that these methods for range estimation can provide the fidelity required for object tracking. Maximum values of relative distance estimation errors in near-ideal conditions are less than 8%.

  20. Measuring vibrational motion in the presence of speckle using off-axis holography.

    PubMed

    Redding, Brandon; Davis, Allen; Kirkendall, Clay; Dandridge, Anthony

    2016-02-20

    We present a holographic laser vibrometer designed to mitigate the effects of speckle noise when measuring the vibrational motion of a rough object. We show that multiplexing the interferometric measurement across 105 pixels provides a 50 dB reduction in the incoherent noise. Using a high-speed camera, this enables a displacement sensitivity of 50  fm/√Hz with a bandwidth of 12.5 kHz when measuring rough objects, representing a 20 dB improvement compared with a commercially available single-detector-based laser vibrometer. Finally, we show that the holographic vibrometer system is capable of stand-off acoustic sensing by measuring the acoustic-induced vibrations of a piece of paper with sensitivity as low as 10 dB (re 20 μPa). The ability to sensitively and noninvasively measure the vibrations of arbitrary rough surfaces could enable new applications in laser vibrometry.

  1. Comparison of Object-Based Image Analysis Approaches to Mapping New Buildings in Accra, Ghana Using Multi-Temporal QuickBird Satellite Imagery

    PubMed Central

    Tsai, Yu Hsin; Stow, Douglas; Weeks, John

    2013-01-01

    The goal of this study was to map and quantify the number of newly constructed buildings in Accra, Ghana between 2002 and 2010 based on high spatial resolution satellite image data. Two semi-automated feature detection approaches for detecting and mapping newly constructed buildings based on QuickBird very high spatial resolution satellite imagery were analyzed: (1) post-classification comparison; and (2) bi-temporal layerstack classification. Feature Analyst software based on a spatial contextual classifier and ENVI Feature Extraction that uses a true object-based image analysis approach of image segmentation and segment classification were evaluated. Final map products representing new building objects were compared and assessed for accuracy using two object-based accuracy measures, completeness and correctness. The bi-temporal layerstack method generated more accurate results compared to the post-classification comparison method due to less confusion with background objects. The spectral/spatial contextual approach (Feature Analyst) outperformed the true object-based feature delineation approach (ENVI Feature Extraction) due to its ability to more reliably delineate individual buildings of various sizes. Semi-automated, object-based detection followed by manual editing appears to be a reliable and efficient approach for detecting and enumerating new building objects. A bivariate regression analysis was performed using neighborhood-level estimates of new building density regressed on a census-derived measure of socio-economic status, yielding an inverse relationship with R2 = 0.31 (n = 27; p = 0.00). The primary utility of the new building delineation results is to support spatial analyses of land cover and land use and demographic change. PMID:24415810

  2. How Prevalent Is Object-Based Attention?

    PubMed Central

    Pilz, Karin S.; Roggeveen, Alexa B.; Creighton, Sarah E.; Bennett, Patrick J.; Sekuler, Allison B.

    2012-01-01

    Previous research suggests that visual attention can be allocated to locations in space (space-based attention) and to objects (object-based attention). The cueing effects associated with space-based attention tend to be large and are found consistently across experiments. Object-based attention effects, however, are small and found less consistently across experiments. In three experiments we address the possibility that variability in object-based attention effects across studies reflects low incidence of such effects at the level of individual subjects. Experiment 1 measured space-based and object-based cueing effects for horizontal and vertical rectangles in 60 subjects comparing commonly used target detection and discrimination tasks. In Experiment 2 we ran another 120 subjects in a target discrimination task in which rectangle orientation varied between subjects. Using parametric statistical methods, we found object-based effects only for horizontal rectangles. Bootstrapping methods were used to measure effects in individual subjects. Significant space-based cueing effects were found in nearly all subjects in both experiments, across tasks and rectangle orientations. However, only a small number of subjects exhibited significant object-based cueing effects. Experiment 3 measured only object-based attention effects using another common paradigm and again, using bootstrapping, we found only a small number of subjects that exhibited significant object-based cueing effects. Our results show that object-based effects are more prevalent for horizontal rectangles, which is in accordance with the theory that attention may be allocated more easily along the horizontal meridian. The fact that so few individuals exhibit a significant object-based cueing effect presumably is why previous studies of this effect might have yielded inconsistent results. The results from the current study highlight the importance of considering individual subject data in addition to commonly used statistical methods. PMID:22348018

  3. SU-E-J-197: Investigation of Microsoft Kinect 2.0 Depth Resolution for Patient Motion Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverstein, E; Snyder, M

    2015-06-15

    Purpose: Investigate the use of the Kinect 2.0 for patient motion tracking during radiotherapy by studying spatial and depth resolution capabilities. Methods: Using code written in C#, depth map data was abstracted from the Kinect to create an initial depth map template indicative of the initial position of an object to be compared to the depth map of the object over time. To test this process, simple setup was created in which two objects were imaged: a 40 cm × 40 cm board covered in non reflective material and a 15 cm × 26 cm textbook with a slightly reflective,more » glossy cover. Each object, imaged and measured separately, was placed on a movable platform with object to camera distance measured. The object was then moved a specified amount to ascertain whether the Kinect’s depth camera would visualize the difference in position of the object. Results: Initial investigations have shown the Kinect depth resolution is dependent on the object to camera distance. Measurements indicate that movements as small as 1 mm can be visualized for objects as close as 50 cm away. This depth resolution decreases linearly with object to camera distance. At 4 m, the depth resolution had decreased to observe a minimum movement of 1 cm. Conclusion: The improved resolution and advanced hardware of the Kinect 2.0 allows for increase of depth resolution over the Kinect 1.0. Although obvious that the depth resolution should decrease with increasing distance from an object given the decrease in number of pixels representing said object, the depth resolution at large distances indicates its usefulness in a clinical setting.« less

  4. Relative Navigation of Formation-Flying Satellites

    NASA Technical Reports Server (NTRS)

    Long, Anne; Kelbel, David; Lee, Taesul; Leung, Dominic; Carpenter, J. Russell; Grambling, Cheryl

    2002-01-01

    This paper compares autonomous relative navigation performance for formations in eccentric, medium and high-altitude Earth orbits using Global Positioning System (GPS) Standard Positioning Service (SPS), crosslink, and celestial object measurements. For close formations, the relative navigation accuracy is highly dependent on the magnitude of the uncorrelated measurement errors. A relative navigation position accuracy of better than 10 centimeters root-mean-square (RMS) can be achieved for medium-altitude formations that can continuously track at least one GPS signal. A relative navigation position accuracy of better than 15 meters RMS can be achieved for high-altitude formations that have sparse tracking of the GPS signals. The addition of crosslink measurements can significantly improve relative navigation accuracy for formations that use sparse GPS tracking or celestial object measurements for absolute navigation.

  5. Diurnal rhythm and concordance between objective and subjective hot flashes: The Hilo Women’s Health Study

    PubMed Central

    Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.

    2010-01-01

    Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538

  6. Documentation of Historical Underground Object in Skorkov Village with Selected Measuring Methods, Data Analysis and Visualization

    NASA Astrophysics Data System (ADS)

    Dlesk, A.

    2016-06-01

    The author analyzes current methods of 3D documentation of historical tunnels in Skorkov village, which lies at the Jizera river, approximately 30 km away from Prague. The area is known as a former military camp from Thirty Years' War in 17th Century. There is an extensive underground compound with one entrance corridor and two transverse, situated approximately 2 to 5 m under the local development. The object has been partly documented by geodetic polar method, intersection photogrammetry, image-based modelling and laser scanning. Data have been analyzed and methods have been compared. Then the 3D model of object has been created and compound with cadastral data, orthophoto, historical maps and digital surface model which was made by photogrammetric method using remotely piloted aircraft system. Then the measuring has been realized with ground penetrating radar. Data have been analyzed and the result compared with real status. All the data have been combined and visualized into one 3D model. Finally, the discussion about advantages and disadvantages of used measuring methods has been livened up. The tested methodology has been also used for other documentation of historical objects in this area. This project has been created as a part of research at EuroGV. s.r.o. Company lead by Ing. Karel Vach CSc. in cooperation with prof. Dr. Ing. Karel Pavelka from Czech Technical University in Prague and Miloš Gavenda, the renovator.

  7. Well-Being With Objects: Evaluating a Museum Object-Handling Intervention for Older Adults in Health Care Settings.

    PubMed

    Thomson, Linda J M; Chatterjee, Helen J

    2016-03-01

    The extent to which a museum object-handling intervention enhanced older adult well-being across three health care settings was examined. The program aimed to determine whether therapeutic benefits could be measured objectively using clinical scales. Facilitator-led, 30 to 40 min sessions handling and discussing museum objects were conducted in acute and elderly care (11 one-to-ones), residential (4 one-to-ones and 1 group of five), and psychiatric (4 groups of five) settings. Pre-post measures of psychological well-being (Positive Affect and Negative Affect Schedule) and subjective wellness and happiness (Visual Analogue Scales) were compared. Positive affect and wellness increased significantly in acute and elderly and residential care though not psychiatric care whereas negative affect decreased and happiness increased in all settings. Examination of audio recordings revealed enhanced confidence, social interaction, and learning. The program allowed adults access to a museum activity who by virtue of age and ill health would not otherwise have engaged with museum objects. © The Author(s) 2014.

  8. Comparative analysis of imaging configurations and objectives for Fourier microscopy.

    PubMed

    Kurvits, Jonathan A; Jiang, Mingming; Zia, Rashid

    2015-11-01

    Fourier microscopy is becoming an increasingly important tool for the analysis of optical nanostructures and quantum emitters. However, achieving quantitative Fourier space measurements requires a thorough understanding of the impact of aberrations introduced by optical microscopes that have been optimized for conventional real-space imaging. Here we present a detailed framework for analyzing the performance of microscope objectives for several common Fourier imaging configurations. To this end, we model objectives from Nikon, Olympus, and Zeiss using parameters that were inferred from patent literature and confirmed, where possible, by physical disassembly. We then examine the aberrations most relevant to Fourier microscopy, including the alignment tolerances of apodization factors for different objective classes, the effect of magnification on the modulation transfer function, and vignetting-induced reductions of the effective numerical aperture for wide-field measurements. Based on this analysis, we identify an optimal objective class and imaging configuration for Fourier microscopy. In addition, the Zemax files for the objectives and setups used in this analysis have been made publicly available as a resource for future studies.

  9. Combination of optically measured coordinates and displacements for quantitative investigation of complex objects

    NASA Astrophysics Data System (ADS)

    Andrae, Peter; Beeck, Manfred-Andreas; Jueptner, Werner P. O.; Nadeborn, Werner; Osten, Wolfgang

    1996-09-01

    Holographic interferometry makes it possible to measure high precision displacement data in the range of the wavelength of the used laser light. However, the determination of 3D- displacement vectors of objects with complex surfaces requires the measurement of 3D-object coordinates not only to consider local sensitivities but to distinguish between in-plane deformation, i.e. strains, and out-of-plane components, i.e. shears, too. To this purpose both the surface displacement and coordinates have to be combined and it is advantageous to make the data available for CAE- systems. The object surface has to be approximated analytically from the measured point cloud to generate a surface mesh. The displacement vectors can be assigned to the nodes of this surface mesh for visualization of the deformation of the object under test. They also can be compared to the results of FEM-calculations or can be used as boundary conditions for further numerical investigations. Here the 3D-object coordinates are measured in a separate topometric set-up using a modified fringe projection technique to acquire absolute phase values and a sophisticated geometrical model to map these phase data onto coordinates precisely. The determination of 3D-displacement vectors requires the measurement of several interference phase distributions for at least three independent sensitivity directions depending on the observation and illumination directions as well as the 3D-position of each measuring point. These geometric quantities have to be transformed into a reference coordinate system of the interferometric set-up in order to calculate the geometric matrix. The necessary transformation can be realized by means of a detection of object features in both data sets and a subsequent determination of the external camera orientation. This paper presents a consistent solution for the measurement and combination of shape and displacement data including their transformation into simulation systems. The described procedure will be demonstrated on an automotive component. Thus more accurate and effective measurement techniques make it possible to bring experimental and numerical displacement analysis closer.

  10. Naming Speed of Adolescents and Young Adults with Attention Deficit Hyperactivity Disorder: Differences in Alphanumeric Versus Color/Object Naming.

    PubMed

    Whipple, Brittany D; Nelson, Jason M

    2016-02-01

    This study investigated the performance of adolescents and young adults with Attention Deficit Hyperactivity Disorder (ADHD), Reading Disorder (RD), and ADHD/RD on measures of alphanumeric and nonalphanumeric naming speed and the relationship between naming speed and academic achievement. The sample (N = 203) included students aged 17-28 years diagnosed with ADHD (n = 83), RD (n = 71), or ADHD/RD (n = 49). Individuals with ADHD performed significantly faster on measures of alphanumeric naming compared with RD and comorbid groups and, within group, demonstrated significantly quicker naming of letters/digits compared with colors/objects. Both alphanumeric rapid naming scores and processing speed scores variably predicted academic achievement scores across groups, whereas nonalphanumeric rapid naming only predicted reading comprehension scores within the ADHD group. Results support findings that older individuals with ADHD show relative weakness in rapid naming of objects and colors. Implications of these findings in regard to assessment of older individuals for ADHD are discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Consistency between subjectively and objectively measured hazard perception skills among young male drivers.

    PubMed

    Ābele, Līva; Haustein, Sonja; Møller, Mette; Martinussen, Laila M

    2018-03-01

    Young male drivers have lower hazard perception skills (HPS) than older and more experienced drivers and a tendency to overestimate their skills in hazardous situations. Both factors contribute to an over-representation in traffic accidents. Based on a sample of 63 drivers aged 18-24, this study compares the consistency of HPS measured by objective and subjective measures and the link between these measures is the key contribution of the study. Both visible and hidden hazards are included. Objective measures of HPS include responsiveness and eye movements while driving in a driving simulator. Subjective measures of HPS include self-reports derived based on the Hazard Perception Questionnaire (HPQ), Driving Skill Questionnaire (DSQ), and Brief Sensation Seeking Scale (BSSS). Results show that drivers who respond to the hazards on time, as compared to drivers who do not respond, have higher scores on subjective measures of HPS and higher driving skills in the visible but not in the hidden condition. Eye movement analysis confirms the difference and shows that response in time to hazards indicate higher HPS and young drivers are poor at detecting hidden hazards. Drivers with a response in time locate the hazard faster, have more fixations, but dwell less on the hazard. At the same time, those who do not respond have a later first fixation and fewer but longer fixations on the hazard. High sensation seeking drivers respond to visible hazards on time, suggesting that sensation seeking does not affect HPS negatively when the hazard is visible. To enhance the HPS among young drivers, the results of this study suggest that specific hazard perception training is relevant, especially for hazards that require more advanced HPS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Blunted vocal affect and expression is not associated with schizophrenia: A computerized acoustic analysis of speech under ambiguous conditions.

    PubMed

    Meaux, Lauren T; Mitchell, Kyle R; Cohen, Alex S

    2018-05-01

    Patients with schizophrenia are consistently rated by clinicians as having high levels of blunted vocal affect and alogia. However, objective technologies have often failed to substantiate these abnormalities. It could be the case that negative symptoms are context-dependent. The present study examined speech elicited under conditions demonstrated to exacerbate thought disorder. The Rorschach Test was administered to 36 outpatients with schizophrenia and 25 nonpatient controls. Replies to separate "perceptual" and "memory" phases were analyzed using validated acoustic analytic methods. Compared to nonpatient controls, schizophrenia patients did not display abnormal speech expression on objective measure of blunted vocal affect or alogia. Moreover, clinical ratings of negative symptoms were not significantly correlated with objective measures. These findings suggest that in patients with schizophrenia, vocal affect/alogia is generally unremarkable under ambiguous conditions. Clarifying the nature of blunted vocal affect and alogia, and how objective measures correspond to what clinicians attend to when making clinical ratings are important directions for future research. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Quantitative comparison of topical aluminum salt solution efficacy for management of sweating: a randomized, controlled trial.

    PubMed

    Swary, Jillian H; West, Dennis P; Kakar, Rohit; Ortiz, Sara; Schaeffer, Matthew R; Veledar, Emir; Alam, Murad

    2015-12-01

    There is a lack of studies objectively comparing the efficacy of topical antiperspirants in reducing sweat. To objectively and quantitatively compare the efficacy of two aluminum salt solutions for the reduction of induced sweating. A subject, rater, and statistician-blinded, randomized, controlled trial. Nineteen subjects were exposed to a standardized heat challenge for 3 h. Topical agent A (20% aluminum chloride hexahydrate) was randomized to either axilla, and topical agent B (1% aluminum acetate) assigned to the contralateral side. A sauna suit induced sweating during three 30-min heat intervals: (1) with no study agents (pre); (2) with both study agents, one on each side; and (3) after the agents were washed off (post). Sweat levels were measured by securing Whatman(®) filter paper to each axilla and measuring the paper weight after each heat interval. The difference in paper weight following each heat interval between Study Agent A and Study Agent B was measured by a gravimetric scale. Topical agent A had a significantly greater effect at reducing axillary sweating than B (P = 0.0002). In a sweating simulation, 20% aluminum chloride hexahydrate quantitatively and objectively appeared to reduce sweat more effectively than 1% aluminum acetate. © 2015 Wiley Periodicals, Inc.

  14. Evaluating roadway surface rating technologies.

    DOT National Transportation Integrated Search

    2015-06-01

    The key project objective was to assess and evaluate the feasibility and accuracy of : custom software used in smartphones to measure road roughness from the : accelerometer data collected from smartphones and compare results with PASER : (Pavement S...

  15. Evaluating Robotic Surgical Skills Performance Under Distractive Environment Using Objective and Subjective Measures.

    PubMed

    Suh, Irene H; LaGrange, Chad A; Oleynikov, Dmitry; Siu, Ka-Chun

    2016-02-01

    Distractions are recognized as a significant factor affecting performance in safety critical domains. Although operating rooms are generally full of distractions, the effect of distractions on robot-assisted surgical (RAS) performance is unclear. Our aim was to investigate the effect of distractions on RAS performance using both objective and subjective measures. Fifteen participants performed a knot-tying task using the da Vinci Surgical System and were exposed to 3 distractions: (1) passive distraction entailed listening to noise with a constant heart rate, (2) active distraction included listening to noise and acknowledging a change of random heart rate from 60 to 120 bpm, and (3) interactive distraction consisted of answering math questions. The objective kinematics of the surgical instrument tips were used to evaluate performance. Electromyography (EMG) of the forearm and hand muscles of the participants were collected. The median EMG frequency (EMG(fmed)) and the EMG envelope (EMG(env)) were analyzed. NASA Task Load Index and Fundamentals of Laparoscopic Surgery score were used to evaluate the subjective performance. One-way repeated analysis of variance was applied to examine the effects of distraction on skills performance. Spearman's correlations were conducted to compare objective and subjective measures. Significant distraction effect was found for all objective kinematics measures (P < .05). There were significant distraction effects for EMG measures (EMG(env), P < .004; EMG(fmed), P = .031). Significant distraction effects were also found for subjective measurements. Distraction impairs surgical skills performance and increases muscle work. Understanding how the surgeons cope with distractions is important in developing surgical education. © The Author(s) 2015.

  16. Comparison of methods to assess change in children’s body composition123

    PubMed Central

    Elberg, Jane; McDuffie, Jennifer R; Sebring, Nancy G; Salaita, Christine; Keil, Margaret; Robotham, Delphine; Reynolds, James C; Yanovski, Jack A

    2008-01-01

    Background Little is known about how simpler and more available methods to measure change in body fatness compare with criterion methods such as dual-energy X-ray absorptiometry (DXA) in children. Objective Our objective was to determine the ability of air-displacement plethysmography (ADP) and formulas based on triceps skinfold thickness (TSF) and bioelectrical impedance analysis (BIA) to estimate changes in body fat over time in children. Design Eighty-six nonoverweight and overweight boys (n = 34) and girls (n = 52) with an average age of 11.0 ± 2.4 y underwent ADP, TSF measurement, BIA, and DXA to estimate body fatness at baseline and 1 ± 0.3 y later. Recent equations were used to estimate percentage body fat by TSF measurement (Dezenberg equation) and by BIA (Suprasongsin and Lewy equations). Percentage body fat estimates by ADP, TSF measurement, and BIA were compared with those by DXA. Results All methods were highly correlated with DXA (P < 0.001). No mean bias for estimates of percentage body fat change was found for ADP (Siri equation) compared with DXA for all subjects examined together, and agreement between body fat estimation by ADP and DXA did not vary with race or sex. Magnitude bias was present for ADP relative to DXA (P < 0.01). Estimates of change in percentage body fat were systematically overestimated by BIA equations (1.37 ± 6.98%; P < 0.001). TSF accounted for only 13% of the variance in percentage body fat change. Conclusion Compared with DXA, there appears to be no noninvasive and simple method to measure changes in children’s percentage body fat accurately and precisely, but ADP performed better than did TSF or BIA. ADP could prove useful for measuring changes in adiposity in children. PMID:15213029

  17. Positive outcomes following gait therapy intervention for hip osteoarthritis: A longitudinal study.

    PubMed

    Solomonow-Avnon, Deborah; Herman, Amir; Levin, Daniel; Rozen, Nimrod; Peled, Eli; Wolf, Alon

    2017-10-01

    Footwear-generated biomechanical manipulation of lower-limb joints was shown to beneficially impact gait and quality of life in knee osteoarthritis patients, but has not been tested in hip osteoarthritis patients. We examined a customized gait treatment program using a biomechanical device shown in previous investigations to be capable of manipulating hip biomechanics via foot center of pressure (COP) modulation. The objective of this study was to assess the treatment program for hip osteoarthritis patients, enrolled in a 1-year prospective investigation, by means of objective gait and spatiotemporal parameters, and subjective quality of life measures. Gait analysis and completion of questionnaires were performed at the start of the treatment (baseline), and after 3, 6, and 12 months. Outcome parameters were evaluated over time using linear mixed effects models, and association between improvement in quality of life measures and change in objective outcomes was tested using mixed effect linear regression models. Quality of life measures improved compared to baseline, accompanied by increased gait speed and cadence. Sagittal-plane hip joint kinetics, kinematics, and spatiotemporal parameters changed throughout the study compared to baseline, in a manner suggesting improvement of gait. The most substantial improvement occurred within 3 months after treatment initiation, after which improvement approximately plateaued, but was sustained at 12 months. Speed and cadence, as well as several sagittal-plane gait parameters, were significant predictors of improvement in quality of life. Evidence suggests that a biomechanical gait therapy program improves subjective and objective outcomes measures and is a valid treatment option for hip osteoarthritis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2222-2232, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. A comparison of the effect of different surgical gloves on objective measurement of fingertip cutaneous sensibility

    PubMed Central

    Bucknor, A; Karthikesalingam, A; Markar, SR; Holt, PJ; Jones, I; Allen-Mersh, TG

    2010-01-01

    INTRODUCTION The prudent selection of surgical gloves can deliver significant efficiency savings. However, objective data are lacking to compare differences in cutaneous sensibility between competing gloves. Therefore, the present study examined the use of a single comparable model of sterile surgical glove from two competing providers, Gammex PF HyGrip® (Ansell Limited, Red Bank, NJ, USA) with Biogel® (Mölnlycke Health Care AB, Göteborg, Sweden). SUBJECTS AND METHODS Cutaneous pressure threshold, static and moving two-point discrimination were measured as indices of objective surgical glove performance in 52 blinded healthcare professionals. RESULTS The mean cutaneous pressure threshold was 0.0680 ± 0.0923 g for skin, 0.411 ± 0.661 g for Ansell gloves and 0.472 ± 0.768 g for Biogel gloves. Skin was significantly more sensitive than Ansell (P< 0.0001) or Biogel (P< 0.0001) gloves (Wilcoxon signed rank test). There was no statistical difference between Biogel and Ansell gloves (P = 0.359). There was no significant difference between static or moving 2-point discrimination of skin and Ansell gloves (P= 0.556, P = 0.617; Wilcoxon signed rank test), skin and Biogel gloves (P= 0.486, P= 0.437; Wilcoxon signed rank test) or Ansell and Biogel gloves (P= 0.843, P= 0.670; Wilcoxon signed rank test). CONCLUSIONS No demonstrable objective difference was found between competing gloves in the outcome measures of cutaneous sensibility and two-point discrimination. However, a difference in subjective preference was noted. Untested factors may underlie this discrepancy, and further research should employ more sophisticated measurements of surgical performance using competing models of surgical glove. PMID:21118618

  19. Soil respiration response to three years of elevated CO2 and N fertilization in ponderosa pine (Pinus ponderosa Doug. ex Laws.)

    Treesearch

    James M. Vose; Katherine J. Elliott; Dale W. Johnson; David T. Tingey; Mark G. Johnson

    1997-01-01

    We measured growing season soil CO2 evolution under elevated atmospheric [CO2 and soil nitrogen (N) additions. Our objectives were to determine treatment effects, quantify seasonal variation, and compare two measurement techniques. Elevated [CO2] treatments were applied in open-top chambers...

  20. Spontaneous Representations of Small Numbers of Objects by Rhesus Macaques: Examinations of Content and Format

    ERIC Educational Resources Information Center

    Hauser, Marc D.; Carey, Susan

    2003-01-01

    The project of comparative cognition benefits from common measures across species. We report here on five experiments using the violation of expectancy looking time measure with free-ranging rhesus macaques ("Macaca mulatta"), each designed to build on current knowledge concerning spontaneous representations of number. Each subject, tested in only…

  1. Comparative Effectiveness of Alternative Administrative Structures. Final Report on a Pilot Investigation. Programme on Institutional Management in Higher Education.

    ERIC Educational Resources Information Center

    Rivett, B. H. P.; And Others

    Initial objectives of this pilot study were to: define the effectiveness and structure of administration in institutions of higher education; explore and identify measures of administrative effectiveness and structure; test the practicability of such definitions and measures against on-going processes at Sussex University; direct, coordinate, and…

  2. Measuring Adult Literacy in Health Care: Performance of the Newest Vital Sign

    ERIC Educational Resources Information Center

    Osborn, Chandra Y.; Weiss, Barry D.; Davis, Terry C.; Skripkauskas, Silvia; Rodrigue, Christopher; Bass, Pat F., III; Wolf, Michael S.

    2007-01-01

    Objective: To compare performance of the newest vital sign (NVS) with existing literacy measures. Methods: We administered the NVS and REALM to 129 patients, and NVS and S-TOFHLA to 119 patients all in public clinics. Results: The NVS demonstrated high sensitivity for detecting limited literacy and moderate specificity (area under the receiver…

  3. Comparison of measured direct normal irradiance data to values calculated using the DISC model for Texas Panhandle

    USDA-ARS?s Scientific Manuscript database

    Direct normal irradiance (DNI) is required in the performance estimation of concentrating solar energy systems. The objective of this paper is to compare measured and modeled DNI data for a site in the Texas Panhandle (Bushland, Texas) to determine the accuracy of the model and where improvements mi...

  4. Two Reference Systems for School Quality Analysis.

    ERIC Educational Resources Information Center

    Danowski, Charles E.

    1967-01-01

    This paper compares key financial measures of the Metropolitan School Study Council (MSSC) with those of the Associated Public School Systems (APSS) to obtain data relative to school system quality. The objectives of the discussion are (1) to describe the 11 year trend from 1955-56 to 1965-66 for each group on measures of net current expenditure…

  5. Objective characterization of airway dimensions using image processing.

    PubMed

    Pepper, Victoria K; Francom, Christian; Best, Cameron A; Onwuka, Ekene; King, Nakesha; Heuer, Eric; Mahler, Nathan; Grischkan, Jonathan; Breuer, Christopher K; Chiang, Tendy

    2016-12-01

    With the evolution of medical and surgical management for pediatric airway disorders, the development of easily translated techniques of measuring airway dimensions can improve the quantification of outcomes of these interventions. We have developed a technique that improves the ability to characterize endoscopic airway dimensions using common bronchoscopic equipment and an open-source image-processing platform. We validated our technique of Endoscopic Airway Measurement (EAM) using optical instruments in simulation tracheas. We then evaluated EAM in a large animal model (Ovis aries, n = 5), comparing tracheal dimensions obtained with EAM to measurements obtained via 3-D fluoroscopic reconstruction. The animal then underwent resection of the measured segment, and direct measurement of this segment was performed and compared to radiographic measurements and those obtained using EAM. The simulation tracheas had a direct measurement of 13.6, 18.5, and 24.2 mm in diameter. The mean difference of diameter in simulation tracheas between direct measurements and measurements obtained using EAM was 0.70 ± 0.57 mm. The excised ovine tracheas had an average diameter of 18.54 ± 0.68 mm. The percent difference in diameter obtained from EAM and from 3-D fluoroscopic reconstruction when compared to measurement of the excised tracheal segment was 4.98 ± 2.43% and 10.74 ± 4.07% respectively. Comparison of these three measurements (EAM, measurement of resected trachea, 3-D fluoroscopic reconstruction) with repeated measures ANOVA demonstrated no statistical significance. Endoscopic airway measurement (EAM) provides equivalent measurements of the airway with the improved versatility of measuring non-circular and multi-level dimensions. Using optical bronchoscopic instruments and open-source image-processing software, our data supports preclinical and clinical translation of an accessible technique to provide objective quantification of airway diameter. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Differences in Self-Reported Physical Limitation Among Older Women and Men in Ismailia, Egypt

    PubMed Central

    2012-01-01

    Objectives. This study explores the reasons for gender differences in self-reported physical limitation among older adults in Ismailia, Egypt. Method. 435 women and 448 men, 50 years and older in Ismailia, Egypt, participated in a social survey and tests of physical performance. Ordered logit models were estimated to compare unadjusted gender differences in reported disability with these differences adjusted sequentially for (a) age and objective measures of physical performance, (b) self-reported morbidities and health care use, and (c) social and economic attributes. Results. Compared with men, women more often reported higher levels of limitation in activities of daily living (ADLs), upper-extremity range of motion (ROM), and lower-extremity gross mobility (GM). Adjusting for age and objective measures of physical performance, women and men had similar odds of self-reporting difficulty with ADLs. With sequential adjustments for the remaining variables, women maintained significantly higher odds of self-reported difficulty with upper-extremity ROM and lower-extremity GM. Discussion. Cross-culturally, gender differences in self-reported disability may arise from objective and subjective perceptions of disability. Collectively, these results and those from prior studies in Bangladesh and the United States suggest that gender gaps in self-reported physical limitation may be associated with the degree of gender equality in society. PMID:22929399

  7. Measurement Issues in Health Disparities Research

    PubMed Central

    Ramírez, Mildred; Ford, Marvella E; Stewart, Anita L; A Teresi, Jeanne

    2005-01-01

    Background Racial and ethnic disparities in health and health care have been documented; the elimination of such disparities is currently part of a national agenda. In order to meet this national objective, it is necessary that measures identify accurately the true prevalence of the construct of interest across diverse groups. Measurement error might lead to biased results, e.g., estimates of prevalence, magnitude of risks, and differences in mean scores. Addressing measurement issues in the assessment of health status may contribute to a better understanding of health issues in cross-cultural research. Objective To provide a brief overview of issues regarding measurement in diverse populations. Findings Approaches used to assess the magnitude and nature of bias in measures when applied to diverse groups include qualitative analyses, classic psychometric studies, as well as more modern psychometric methods. These approaches should be applied sequentially, and/or iteratively during the development of measures. Conclusions Investigators performing comparative studies face the challenge of addressing measurement equivalence, crucial for obtaining accurate results in cross-cultural comparisons. PMID:16179000

  8. Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Black, Jonathan T.

    2003-01-01

    Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored, circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retroreflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

  9. Videogrammetry Using Projected Circular Targets: Proof-of-Concept Test

    NASA Technical Reports Server (NTRS)

    Black, Jonathan T.; Pappa, Richard S.

    2003-01-01

    Videogrammetry is the science of calculating 3D object coordinates as a function of time from image sequences. It expands the method of photogrammetry to multiple time steps enabling the object to be characterized dynamically. Photogrammetry achieves the greatest accuracy with high contrast, solid-colored circular targets. The high contrast is most often effected using retro-reflective targets attached to the measurement article. Knowledge of the location of each target allows those points to be tracked in a sequence of images, thus yielding dynamic characterization of the overall object. For ultra-lightweight and inflatable gossamer structures (e.g. solar sails, inflatable antennae, sun shields, etc.) where it may be desirable to avoid physically attaching retro-targets, a high-density grid of projected circular targets - called dot projection - is a viable alternative. Over time the object changes shape or position independently of the dots. Dynamic behavior, such as deployment or vibration, can be characterized by tracking the overall 3D shape of the object instead of tracking specific object points. To develop this method, an oscillating rigid object was measured using both retro- reflective targets and dot projection. This paper details these tests, compares the results, and discusses the overall accuracy of dot projection videogrammetry.

  10. Comparison of objective and subjective assessments of sleep time in subjects with bipolar disorder.

    PubMed

    Gonzalez, R; Tamminga, C; Tohen, M; Suppes, T

    2013-07-01

    Sleep disturbance is a core feature of bipolar disorder. To date there are a limited number of studies that compare subjective and objective measures of sleep in populations of subjects with mood disorders. This study evaluated the relationship between subjective and objective measurements of total sleep time (TST) in a bipolar type I disorder (BD I) population. Thirty-nine subjects diagnosed with BD I participated in the study. Mood symptoms were assessed via YMRS and IDS-30-C. Subjects wore an actigraph device and maintained a sleep diary for seven consecutive days. Differences between TST as estimated via sleep diaries and actigraphy were calculated. Objective and subjective measures of TST were significantly correlated (r=0.5151, p=0.0008). Secondary analysis revealed that the severity of depressive symptoms did correlate to this discrepancy (t=2.65, p=0.01). The impact that medications have on the accuracy of TST reported was not investigated. Also, sleep diaries may have acted to prompt subjects to pay closer attention to their sleep habits and therefore more accurately report TST than in the average clinical setting. The results of the current study demonstrate a significant correlation between the estimation of TST as measured objectively via actigraphy and subjectively via sleep diaries in BD patients. Mood symptomotology might impact the accuracy of TST reported. Further study is warranted. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Different Gestalt Processing for Different Actions? Comparing Object-Directed Reaching and Looking Time Measures

    ERIC Educational Resources Information Center

    Vishton, P.M.; Ware, E.A.; Badger, A.N.

    2005-01-01

    Six experiments compared the Gestalt processing that mediates infant reaching and looking behaviors. Experiment 1 demonstrated that the positioning and timing of 8- and 9-month-olds' reaching was influenced by remembered relative motion. Experiment 2 suggested that a visible gap, without this relative motion, was not sufficient to produce these…

  12. An Evaluation of a Self-Paced Approach to Elementary Chemistry Instruction.

    ERIC Educational Resources Information Center

    Schaumburg, Gary F.

    The objectives of this study were: (1) to compare retention rates between self-paced (SP) and classical lecture (CL) chemistry students as measured by the proportion of students who received a withdrawal or unofficial withdrawal grade; (2) as indicated by the distribution of final grades, to compare student achievement between SP and CL students;…

  13. A Comparative Analysis of the Costs of Administration of an OSCE.

    ERIC Educational Resources Information Center

    Cusimano, Michael D.; And Others

    1994-01-01

    A study compared the costs of a six-station structured oral examination and an objective structured clinical examination (OSCE) for a surgery clerkship, assessing both faculty and materials costs. The OSCE was found to be more time consuming and expensive. Cost-cutting measures and guidelines to assist medical schools in selecting test type are…

  14. Are Self-Management Interventions Suitable for All? Comparing Obese Versus Nonobese Type 2 Diabetes Patients

    ERIC Educational Resources Information Center

    Kroese, Floor M.; Adriaanse, Marieke A.; De Ridder, Denise T. D.

    2013-01-01

    Objective: The aim of the current study was to compare obese and nonobese type 2 diabetes patients at baseline and after participating in an existing self-management intervention (i.e., "Beyond Good Intentions") on cognitive, self-care, and behavioral measures to examine whether both groups are equally prepared and able to adopt…

  15. Theory of planned behaviour variables and objective walking behaviour do not show seasonal variation in a randomised controlled trial

    PubMed Central

    2014-01-01

    Background Longitudinal studies have shown that objectively measured walking behaviour is subject to seasonal variation, with people walking more in summer compared to winter. Seasonality therefore may have the potential to bias the results of randomised controlled trials if there are not adequate statistical or design controls. Despite this there are no studies that assess the impact of seasonality on walking behaviour in a randomised controlled trial, to quantify the extent of such bias. Further there have been no studies assessing how season impacts on the psychological predictors of walking behaviour to date. The aim of the present study was to assess seasonal differences in a) objective walking behaviour and b) Theory of Planned Behaviour (TPB) variables during a randomised controlled trial of an intervention to promote walking. Methods 315 patients were recruited to a two-arm cluster randomised controlled trial of an intervention to promote walking in primary care. A series of repeated measures ANCOVAs were conducted to examine the effect of season on pedometer measures of walking behaviour and TPB measures, assessed immediately post-intervention and six months later. Hierarchical regression analyses were conducted to assess whether season moderated the prediction of intention and behaviour by TPB measures. Results There were no significant differences in time spent walking in spring/summer compared to autumn/winter. There was no significant seasonal variation in most TPB variables, although the belief that there will be good weather was significantly higher in spring/summer (F = 19.46, p < .001). Season did not significantly predict intention or objective walking behaviour, or moderate the effects of TPB variables on intention or behaviour. Conclusion Seasonality does not influence objectively measured walking behaviour or psychological variables during a randomised controlled trial. Consequently physical activity behaviour outcomes in trials will not be biased by the season in which they are measured. Previous studies may have overestimated the extent of seasonality effects by selecting the most extreme summer and winter months to assess PA. In addition, participants recruited to behaviour change interventions might have higher levels of motivation to change and are less affected by seasonal barriers. Trial registration Current Controlled Trials ISRCTN95932902 PMID:24499405

  16. Safety impacts of Design Exceptions in Utah

    DOT National Transportation Integrated Search

    2012-06-01

    The objective of this research was to compare safety, measured by expected crash frequency and severity, on road segments where design exceptions were approved and constructed to similar road segments where no design exceptions were approved or const...

  17. Safety Impacts of Design Exceptions in Utah

    DOT National Transportation Integrated Search

    2012-08-01

    The objective of this research was to compare safety, measured by expected crash frequency and severity, on road segments where design exceptions were approved and constructed to similar road segments where no design exceptions were approved or const...

  18. Subgroups Among Opiate Addicts

    ERIC Educational Resources Information Center

    Berzins, Juris I.; And Others

    1974-01-01

    The principal objective of the present investigation was to delineate homogeneous MMPI profile subgroups (types) through multivariate clustering procedures and to compare the derived (replicable) types on measures of the components of "sociopathy" as well as on other psychometric devices. (Author)

  19. Comparison of solid shapes geometry derived by a laser scanner and a total station

    NASA Astrophysics Data System (ADS)

    Sidiropoulos, Andreas; Lakakis, Konstantinos

    2016-08-01

    The laser scanning technology has become a common method for the daily applications of a large variety of scientists and professionals. Even for more sophisticated projects, laser scanners have been proved a very useful tool at researchers' and engineers' disposal. In this paper, we investigated the ability of a laser scanner compared to the ability of a total station to provide the geometry of solids. The tests were made in the laboratory facilities of the Aristotle University of Thessaloniki, in a variety of distances between the measuring instrument and the object. The solids that were used differ in shape, material and color. The objects are a wooden cube, a metal cube and a wooden pyramid. The absolute dimensions of the solid shapes were provided by the use of a caliper and were compared to the dimensions that were calculated by the coordinates produced by the total station and laser scanner measurements.

  20. Chromatic dispersive confocal technology for intra-oral scanning: first in-vitro results

    NASA Astrophysics Data System (ADS)

    Ertl, T.; Zint, M.; Konz, A.; Brauer, E.; Hörhold, H.; Hibst, R.

    2015-02-01

    Various test objects, plaster models, partially equipped with extracted teeth and pig jaws representing various clinical situations of tooth preparations were used for in-vitro scanning tests with an experimental intra-oral scanning system based on chromatic-dispersive confocal technology. Scanning results were compared against data sets of the same object captured by an industrial μCT measuring system. Compared to μCT data an average error of 18 - 30 μm was achieved for a single tooth scan area and less than 40 to 60 μm error measured over the restoration + the neighbor teeth and pontic areas up to 7 units. Mean error for a full jaw is within 100 - 140 μm. The length error for a 3 - 4 unit bridge situation form contact point to contact point is below 100 μm and excellent interproximal surface coverage and prep margin clarity was achieved.

  1. Using relative survival measures for cross-sectional and longitudinal benchmarks of countries, states, and districts: the BenchRelSurv- and BenchRelSurvPlot-macros

    PubMed Central

    2013-01-01

    Background The objective of screening programs is to discover life threatening diseases in as many patients as early as possible and to increase the chance of survival. To be able to compare aspects of health care quality, methods are needed for benchmarking that allow comparisons on various health care levels (regional, national, and international). Objectives Applications and extensions of algorithms can be used to link the information on disease phases with relative survival rates and to consolidate them in composite measures. The application of the developed SAS-macros will give results for benchmarking of health care quality. Data examples for breast cancer care are given. Methods A reference scale (expected, E) must be defined at a time point at which all benchmark objects (observed, O) are measured. All indices are defined as O/E, whereby the extended standardized screening-index (eSSI), the standardized case-mix-index (SCI), the work-up-index (SWI), and the treatment-index (STI) address different health care aspects. The composite measures called overall-performance evaluation (OPE) and relative overall performance indices (ROPI) link the individual indices differently for cross-sectional or longitudinal analyses. Results Algorithms allow a time point and a time interval associated comparison of the benchmark objects in the indices eSSI, SCI, SWI, STI, OPE, and ROPI. Comparisons between countries, states and districts are possible. Exemplarily comparisons between two countries are made. The success of early detection and screening programs as well as clinical health care quality for breast cancer can be demonstrated while the population’s background mortality is concerned. Conclusions If external quality assurance programs and benchmark objects are based on population-based and corresponding demographic data, information of disease phase and relative survival rates can be combined to indices which offer approaches for comparative analyses between benchmark objects. Conclusions on screening programs and health care quality are possible. The macros can be transferred to other diseases if a disease-specific phase scale of prognostic value (e.g. stage) exists. PMID:23316692

  2. Smartphone-Based Self-Assessment of Stress in Healthy Adult Individuals: A Systematic Review

    PubMed Central

    Þórarinsdóttir, Helga; Kessing, Lars Vedel

    2017-01-01

    Background Stress is a common experience in today’s society. Smartphone ownership is widespread, and smartphones can be used to monitor health and well-being. Smartphone-based self-assessment of stress can be done in naturalistic settings and may potentially reflect real-time stress level. Objective The objectives of this systematic review were to evaluate (1) the use of smartphones to measure self-assessed stress in healthy adult individuals, (2) the validity of smartphone-based self-assessed stress compared with validated stress scales, and (3) the association between smartphone-based self-assessed stress and smartphone generated objective data. Methods A systematic review of the scientific literature was reported and conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement. The scientific databases PubMed, PsycINFO, Embase, IEEE, and ACM were searched and supplemented by a hand search of reference lists. The databases were searched for original studies involving healthy individuals older than 18 years, measuring self-assessed stress using smartphones. Results A total of 35 published articles comprising 1464 individuals were included for review. According to the objectives, (1) study designs were heterogeneous, and smartphone-based self-assessed stress was measured using various methods (e.g., dichotomized questions on stress, yes or no; Likert scales on stress; and questionnaires); (2) the validity of smartphone-based self-assessed stress compared with validated stress scales was investigated in 3 studies, and of these, only 1 study found a moderate statistically significant positive correlation (r=.4; P<.05); and (3) in exploratory analyses, smartphone-based self-assessed stress was found to correlate with some of the reported smartphone generated objective data, including voice features and data on activity and phone usage. Conclusions Smartphones are being used to measure self-assessed stress in different contexts. The evidence of the validity of smartphone-based self-assessed stress is limited and should be investigated further. Smartphone generated objective data can potentially be used to monitor, predict, and reduce stress levels. PMID:28193600

  3. Preoperative prediction of lymph node metastasis and deep stromal invasion in women with invasive cervical cancer: prospective multicenter study using 2D and 3D ultrasound.

    PubMed

    Pálsdóttir, K; Fischerova, D; Franchi, D; Testa, A; Di Legge, A; Epstein, E

    2015-04-01

    To determine how various objective two-dimensional (2D) and three-dimensional (3D) ultrasound parameters allow prediction of deep stromal tumor invasion and lymph node involvement, in comparison to subjective ultrasound assessment, in women scheduled for surgery for cervical cancer. This was a prospective multicenter trial including 104 women with cervical cancer at FIGO Stages IA2-IIB, verified histologically. Patients scheduled for surgery underwent a preoperative ultrasound examination. The value of various 2D (size, color score) and 3D (volume, vascular indices) ultrasound parameters was compared to that of subjective assessment in the prediction of deep stromal tumor invasion and lymph node involvement. Histology obtained from radical hysterectomy or trachelectomy and pelvic lymphadenectomy was considered as the gold standard for assessment. All women underwent pelvic lymphadenectomy, with 99 (95%) undergoing subsequent radical surgery; five underwent only pelvic lymphadenectomy because of the presence of a positive sentinel lymph node. Women with deep stromal invasion or lymph node involvement had significantly larger tumors (diameter and volume) but there was no correlation with vascular indices measured on 3D ultrasound. Subjective evaluation was superior (AUC, 0.93; sensitivity, 90.5%; specificity, 97.2%) in the prediction of deep stromal invasion when compared to any objective measurement technique, with maximal tumor diameter at 20.5-mm cut-off (AUC, 0.83; sensitivity, 90.5%; specificity, 61.1%) and 3D tumor volume at 9.1-mm(3) cut-off (AUC, 0.85; sensitivity, 79.4%; specificity, 83.3%) providing the best performance among the objective parameters. Both subjective assessment and objective measurements were poorly predictive of lymph node involvement. In women with cervical cancer, subjective ultrasound evaluation allowed better prediction of deep stromal invasion than did objective measurements; however, neither subjective evaluation nor objective parameters were adequate to predict lymph node involvement. 3D vascular indices were ineffective in the prediction of advanced stages of the disease. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  4. Effects of a Web-Based Personalized Intervention on Physical Activity in European Adults: A Randomized Controlled Trial

    PubMed Central

    Celis-Morales, Carlos; Fallaize, Rosalind; Macready, Anna L; Kolossa, Silvia; Woolhead, Clara; O'Donovan, Clare B; Forster, Hannah; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Lambrinou, Christina-Paulina; Moschonis, George; Surwillo, Agnieszka; Godlewska, Magdalena; Goris, Annelies; Hoonhout, Jettie; Drevon, Christian A; Manios, Yannis; Traczyk, Iwona; Walsh, Marianne C; Gibney, Eileen R; Brennan, Lorraine; Martinez, J Alfredo; Lovegrove, Julie A; Gibney, Michael J; Daniel, Hannelore; Mathers, John C; Saris, Wim HM

    2015-01-01

    Background The high prevalence of physical inactivity worldwide calls for innovative and more effective ways to promote physical activity (PA). There are limited objective data on the effectiveness of Web-based personalized feedback on increasing PA in adults. Objective It is hypothesized that providing personalized advice based on PA measured objectively alongside diet, phenotype, or genotype information would lead to larger and more sustained changes in PA, compared with nonpersonalized advice. Methods A total of 1607 adults in seven European countries were randomized to either a control group (nonpersonalized advice, Level 0, L0) or to one of three personalized groups receiving personalized advice via the Internet based on current PA plus diet (Level 1, L1), PA plus diet and phenotype (Level 2, L2), or PA plus diet, phenotype, and genotype (Level 3, L3). PA was measured for 6 months using triaxial accelerometers, and self-reported using the Baecke questionnaire. Outcomes were objective and self-reported PA after 3 and 6 months. Results While 1270 participants (85.81% of 1480 actual starters) completed the 6-month trial, 1233 (83.31%) self-reported PA at both baseline and month 6, but only 730 (49.32%) had sufficient objective PA data at both time points. For the total cohort after 6 months, a greater improvement in self-reported total PA (P=.02) and PA during leisure (nonsport) (P=.03) was observed in personalized groups compared with the control group. For individuals advised to increase PA, we also observed greater improvements in those two self-reported indices (P=.006 and P=.008, respectively) with increased personalization of the advice (L2 and L3 vs L1). However, there were no significant differences in accelerometer results between personalized and control groups, and no significant effect of adding phenotypic or genotypic information to the tailored feedback at month 3 or 6. After 6 months, there were small but significant improvements in the objectively measured physical activity level (P<.05), moderate PA (P<.01), and sedentary time (P<.001) for individuals advised to increase PA, but these changes were similar across all groups. Conclusions Different levels of personalization produced similar small changes in objective PA. We found no evidence that personalized advice is more effective than conventional “one size fits all” guidelines to promote changes in PA in our Web-based intervention when PA was measured objectively. Based on self-reports, PA increased to a greater extent with more personalized advice. Thus, it is crucial to measure PA objectively in any PA intervention study. Trial Registration ClinicalTrials.gov NCT01530139; http://clinicaltrials.gov/show/NCT01530139 (Archived by WebCite at: http://www.webcitation.org/6XII1QwHz) PMID:26467573

  5. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction?

    PubMed

    Hastings, Gareth D; Marsack, Jason D; Nguyen, Lan Chi; Cheng, Han; Applegate, Raymond A

    2017-05-01

    To prospectively examine whether using the visual image quality metric, visual Strehl (VSX), to optimise objective refraction from wavefront error measurements can provide equivalent or better visual performance than subjective refraction and which refraction is preferred in free viewing. Subjective refractions and wavefront aberrations were measured on 40 visually-normal eyes of 20 subjects, through natural and dilated pupils. For each eye a sphere, cylinder, and axis prescription was also objectively determined that optimised visual image quality (VSX) for the measured wavefront error. High contrast (HC) and low contrast (LC) logMAR visual acuity (VA) and short-term monocular distance vision preference were recorded and compared between the VSX-objective and subjective prescriptions both undilated and dilated. For 36 myopic eyes, clinically equivalent (and not statistically different) HC VA was provided with both the objective and subjective refractions (undilated mean ± S.D. was -0.06 ± 0.04 with both refractions; dilated was -0.05 ± 0.04 with the objective, and -0.05 ± 0.05 with the subjective refraction). LC logMAR VA provided by the objective refraction was also clinically equivalent and not statistically different to that provided by the subjective refraction through both natural and dilated pupils for myopic eyes. In free viewing the objective prescription was preferred over the subjective by 72% of myopic eyes when not dilated. For four habitually undercorrected high hyperopic eyes, the VSX-objective refraction was more positive in spherical power and VA poorer than with the subjective refraction. A method of simultaneously optimising sphere, cylinder, and axis from wavefront error measurements, using the visual image quality metric VSX, is described. In myopic subjects, visual performance, as measured by HC and LC VA, with this VSX-objective refraction was found equivalent to that provided by subjective refraction, and was typically preferred over subjective refraction. Subjective refraction was preferred by habitually undercorrected hyperopic eyes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  6. Motion coherence affects human perception and pursuit similarly.

    PubMed

    Beutter, B R; Stone, L S

    2000-01-01

    Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.

  7. Motion coherence affects human perception and pursuit similarly

    NASA Technical Reports Server (NTRS)

    Beutter, B. R.; Stone, L. S.

    2000-01-01

    Pursuit and perception both require accurate information about the motion of objects. Recovering the motion of objects by integrating the motion of their components is a difficult visual task. Successful integration produces coherent global object motion, while a failure to integrate leaves the incoherent local motions of the components unlinked. We compared the ability of perception and pursuit to perform motion integration by measuring direction judgments and the concomitant eye-movement responses to line-figure parallelograms moving behind stationary rectangular apertures. The apertures were constructed such that only the line segments corresponding to the parallelogram's sides were visible; thus, recovering global motion required the integration of the local segment motion. We investigated several potential motion-integration rules by using stimuli with different object, vector-average, and line-segment terminator-motion directions. We used an oculometric decision rule to directly compare direction discrimination for pursuit and perception. For visible apertures, the percept was a coherent object, and both the pursuit and perceptual performance were close to the object-motion prediction. For invisible apertures, the percept was incoherently moving segments, and both the pursuit and perceptual performance were close to the terminator-motion prediction. Furthermore, both psychometric and oculometric direction thresholds were much higher for invisible apertures than for visible apertures. We constructed a model in which both perception and pursuit are driven by a shared motion-processing stage, with perception having an additional input from an independent static-processing stage. Model simulations were consistent with our perceptual and oculomotor data. Based on these results, we propose the use of pursuit as an objective and continuous measure of perceptual coherence. Our results support the view that pursuit and perception share a common motion-integration stage, perhaps within areas MT or MST.

  8. Effect of sway on image fidelity in whole-body digitizing

    NASA Astrophysics Data System (ADS)

    Corner, Brian D.; Hu, Anmin

    1998-03-01

    For 3D digitizers to be useful data collection tools in scientific and human factors engineering applications, the models created from scan data must match the original object very closely. Factors such as ambient light, characteristics of the object's surface, and object movement, among others can affect the quality of the image produced by any 3D digitizing system. Recently, Cyberware has developed a whole body digitizer for collecting data on human size and shape. With a digitizing time of about 15 seconds, the effect subject movement, or sway, on model fidelity is an important issue to be addressed. The effect of sway is best measured by comparing the dimensions of an object of known geometry to the model of the same object captured by the digitizer. Since it is difficult to know the geometry of a human body accurately, it was decided to compare an object of simple geometry to its digitized counterpart. Preliminary analysis showed that a single cardboard tube would provide the best artifact for detecting sway. A tube was attached to the subjects using supports that allowed the cylinder to stand away from the body. The stand-off was necessary to minimize occluded areas. Multiple scans were taken of 1 subject and the cylinder extracted from the images. Comparison of the actual cylinder dimensions to those extracted from the whole body images found the effect of sway to be minimal. This follows earlier findings that anthropometric dimensions extracted from whole body scans are very close to the same dimensions measured using standard manual methods. Recommendations for subject preparation and stabilization are discussed.

  9. Analyzing course objectives: assessing critical thinking in the pharmacy curriculum.

    PubMed

    Vuchetich, Phillip J; Hamilton, William R; Ahmad, S Omar; Makoid, Michael C

    2006-01-01

    Assessment of critical thinking objectives in a pharmacy program curriculum is an important part of program assessment. This study measures the proportion of cognitive learning objectives at various levels of Bloom's taxonomy throughout the required curriculum using the stated objectives in course syllabi (the explicit curriculum). In one entry level doctor of pharmacy program, 54.90% of cognitive objectives identified critical thinking outcomes using the rubric of Bloom's level 3 or higher as an indicator of critical thinking. In this program, there was a similar percent of critical thinking objectives in each of the first three years, but the final year of the curriculum had a higher percent of critical thinking objectives than each of the first three years (p = 0.0018, Kruskal-Wallis test). The increase in critical thinking in the final year suggests that the explicit expectations in the syllabi are weighted toward a higher percent of critical thinking objectives during clinical rotations. The methods described in the study may serve as tools for a curriculum committee or program assessment team to compare critical thinking in the curriculum at different points in time, and may assist in curricular mapping efforts. These methods may complement studies measuring the implicit curriculum (that which the faculty actually teach, which may not be stated in the explicit curriculum.).

  10. Agreement between self-reported sleep patterns and actigraphy in fibromyalgia and healthy women.

    PubMed

    Segura-Jiménez, Víctor; Camiletti-Moirón, Daniel; Munguía-Izquierdo, Diego; Álvarez-Gallardo, Inmaculada C; Ruiz, Jonatan R; Ortega, Francisco B; Delgado-Fernández, Manuel

    2015-01-01

    To examine the agreement between objective (accelerometer) and subjective measures of sleep in fibromyalgia women (FW) and healthy women (HW). To identify explanatory variables of the discrepancies between the objective and subjective measures in FW and in HW. 127 diagnosed FW and 53 HW filled the Fibromyalgia Impact Questionnaire (FIQ) and wore the SenseWear Pro Armband (SWA) for 7 days in order to assess sleep over the last week. Participants completed the Pittsburgh Sleep Quality Index (PSQI) when the SWA was returned. The SWA showed greater total duration (74 vs. 88 min/day) and average duration (7 vs. 9 min) of wake after sleep onset in FW compared with HW. The PSQI showed poorer sleep quality in all the variables studied in FW than in HW (all, p<0.001), except time in bed. There was a lack of inter-method agreement for total sleep time, sleep time without naps and sleep latency in FW. Age and educational status explained the inter-method mean difference in sleep time in FW. High discrepancy in sleep time between the SWA and the PSQI was related to higher FIQ scores (p<0.05). The objective measure only showed higher frequency and average duration of wake after sleep onset in FW compared with HW. The agreement between the SWA and the PSQI measures of sleep were poor in the FW group. Age, educational level and the impact of fibromyalgia might be explanatory variables of the inter-method discrepancies in FW.

  11. Objective but not subjective sleep predicts memory in community-dwelling older adults.

    PubMed

    Cavuoto, Marina G; Ong, Ben; Pike, Kerryn E; Nicholas, Christian L; Bei, Bei; Kinsella, Glynda J

    2016-08-01

    Research on the relationship between habitual sleep patterns and memory performance in older adults is limited. No previous study has used objective and subjective memory measures in a large, older-aged sample to examine the association between sleep and various domains of memory. The aim of this study was to examine the association between objective and subjective measures of sleep with memory performance in older adults, controlling for the effects of potential confounds. One-hundred and seventy-three community-dwelling older adults aged 65-89 years in Victoria, Australia completed the study. Objective sleep quality and length were ascertained using the Actiwatch 2 Mini-Mitter, while subjective sleep was measured using the Pittsburgh Sleep Quality Index. Memory was indexed by tests of retrospective memory (Hopkins Verbal Learning Test - Revised), working memory (n-back, 2-back accuracy) and prospective memory (a habitual button pressing task). Compared with normative data, overall performance on retrospective memory function was within the average range. Hierarchical regression was used to determine whether objective or subjective measures of sleep predicted memory performances after controlling for demographics, health and mood. After controlling for confounds, actigraphic sleep indices (greater wake after sleep onset, longer sleep-onset latency and longer total sleep time) predicted poorer retrospective (∆R(2)  = 0.05, P = 0.016) and working memory (∆R(2)  = 0.05, P = 0.047). In contrast, subjective sleep indices did not significantly predict memory performances. In community-based older adults, objectively-measured, habitual sleep indices predict poorer memory performances. It will be important to follow the sample longitudinally to determine trajectories of change over time. © 2016 European Sleep Research Society.

  12. Designing an experiment to measure cellular interaction forces

    NASA Astrophysics Data System (ADS)

    McAlinden, Niall; Glass, David G.; Millington, Owain R.; Wright, Amanda J.

    2013-09-01

    Optical trapping is a powerful tool in Life Science research and is becoming common place in many microscopy laboratories and facilities. The force applied by the laser beam on the trapped object can be accurately determined allowing any external forces acting on the trapped object to be deduced. We aim to design a series of experiments that use an optical trap to measure and quantify the interaction force between immune cells. In order to cause minimum perturbation to the sample we plan to directly trap T cells and remove the need to introduce exogenous beads to the sample. This poses a series of challenges and raises questions that need to be answered in order to design a set of effect end-point experiments. A typical cell is large compared to the beads normally trapped and highly non-uniform - can we reliably trap such objects and prevent them from rolling and re-orientating? In this paper we show how a spatial light modulator can produce a triple-spot trap, as opposed to a single-spot trap, giving complete control over the object's orientation and preventing it from rolling due, for example, to Brownian motion. To use an optical trap as a force transducer to measure an external force you must first have a reliably calibrated system. The optical trapping force is typically measured using either the theory of equipartition and observing the Brownian motion of the trapped object or using an escape force method, e.g. the viscous drag force method. In this paper we examine the relationship between force and displacement, as well as measuring the maximum displacement from equilibrium position before an object falls out of the trap, hence determining the conditions under which the different calibration methods should be applied.

  13. Shape Measurement by Means of Phase Retrieval using a Spatial Light Modulator

    NASA Astrophysics Data System (ADS)

    Agour, Mostafa; Huke, Philipp; Kopylow, Christoph V.; Falldorf, Claas

    2010-04-01

    We present a novel approach to investigate the shape of a diffusely reflecting technical object. It is based on a combination of a multiple-illumination contouring procedure and phase retrieval from a set of intensity measurements. Special consideration is given to the design of the experimental configuration for phase retrieval and the iterative algorithm to extract the 3D phase map. It is mainly based on a phase-only spatial light modulator (SLM) in the Fourier domain of a 4f-imaging system. The SLM is used to modulate the light incident in the Fourier plane with the transfer function of propagation. Thus, a set of consecutive intensity measurements of the wave field scattered by the investigated object in various propagation states can be realized in a common recording plane. In contrast to already existing methods, no mechanical adjustment is required during the recording process and thus the measuring time is considerably reduced. The method is applied to investigate the shape of micro-objects obtained from a metalforming process. Finally, the experimental results are compared to those provided by a standard interferometric contouring procedure.

  14. The evaluation of three treatments for plantar callus: a three-armed randomised, comparative trial using biophysical outcome measures.

    PubMed

    Hashmi, Farina; Nester, Christopher J; Wright, Ciaran R F; Lam, Sharon

    2016-05-17

    Callus is one of the most common foot skin complaints experienced by people of all ages. These painful and unsightly lesions often result in disability. The 'gold standard' of treatment is scalpel debridement by a trained specialist; however, people also seek over-the-counter remedies. There is a lack of clinical evidence for the efficacy of such products, which makes selection by patients and practitioners difficult. This randomised, three-armed, parallel, comparative trial aimed to test the efficacy of two home treatments for plantar callus using novel, objective outcome measures (skin hydration using the capacitance method; elasticity using negative pressure application; and surface texture using imaging). Additional outcome measures were: size of callus, quality of life (Foot Health Status Questionnaire) and self-reported participant satisfaction and compliance. The results were compared to a podiatry treatment. Participants were randomly allocated to one of three groups: potassium hydroxide (KOH, 40 %); trichloroacetic acid (TCA); and podiatry treatment. Participants were followed for 3 weeks after their initial intervention appointment (days 7, 14 and 21). The primary outcomes were the change from baseline in callus hydration, elasticity, texture, and size at each of the three time points. The secondary outcomes where: change in quality of life 21 days after treatment; resolution of calluses via visual inspection; and participant compliance and perception. Forty-six participants (61 ft) with plantar calluses were recruited. The podiatry treatment showed immediate and significant changes in all objective outcomes, associated foot pain and function (p <0.01). Lesser changes in skin quality and perceived pain and functional benefits occurred with TCA and KOH over 21 days. This is the first study where objective outcome measures have been used to measure changes in the nature of skin in response to callus treatments. We found significant differences in plantar callus in response to podiatry and two home treatments. The podiatry treatment showed immediate and significant changes in skin and associated foot pain and function. Lesser, but sometimes comparable, changes in skin and perceived pain and functional benefits occurred with TCA and KOH over 21 days. ISRCTN14751843 : date of registration: 30 April 2015.

  15. Spitzer DDT observations of the interstellar comet A/2017 U1

    NASA Astrophysics Data System (ADS)

    Trilling, David; Hora, Joe; Mommert, Michael; Carey, Sean; Lisse, Carey; Werner, Mike; Chesley, Steve; Emery, Josh; Fazio, Giovanni; Fernandez, Yan; Harris, Alan; Marengo, Massimo; Mueller, Migo; Roegge, Alissa; Smith, Howard; Smith, Nathan; Weaver, Hal

    2017-11-01

    We propose to observe the newly discovered interstellar comet A/2017 U1 to measure its diameter and albedo. Little is known about this object, which presumably formed in another planetary system. This is the only opportunity *ever* to determine the albedo of this object, which will help us understand how planetary system formation in other systems compares to what occurred in our Solar System. The proposed observations -- requiring 32.6 hours in late November -- are the last telescopic observations that will ever be made of this object. The return from these proposed observations would be tremendous -- characterizing the first ever known object from beyond our Solar System. Because the object is faint and fading, these observations must be made as soon as possible.

  16. Herbig-Haro objects as the heads of radiative jets

    NASA Technical Reports Server (NTRS)

    Blondin, John M.; Konigl, Arieh; Fryxell, Bruce A.

    1989-01-01

    The interpretation of certain HH objects as the heads of nonadiabatic supersonic jets is examined using two-dimensional numerical simulations. It is found that radiative jets develop a dense shell between the jet shock and the leading bow shock when the cooling distance behind either one of these shocks is smaller than the jet radius. It is proposed that the radiatively cooling shell may account for the variable emission pattern from objects like HH 1. Also, it is suggested that HH objects with measured space velocities that exceed the spectroscopically inferred shock velocities could correspond to heavy jets in which the bow shock is effectively adiabatic. Low-excitation objects in which these velocities are comparable may represent light jets where the jet shock is nonradiative.

  17. Pathways to Program Success: A Qualitative Comparative Analysis (QCA) of Communities Putting Prevention to Work Case Study Programs

    PubMed Central

    Kane, Heather; Hinnant, Laurie; Day, Kristine; Council, Mary; Tzeng, Janice; Soler, Robin; Chambard, Megan; Roussel, Amy; Heirendt, Wendy

    2016-01-01

    Objective To examine the elements of capacity, a measure of organizational resources supporting program implementation that result in successful completion of public health program objectives in a public health initiative serving 50 communities. Design We used crisp set Qualitative Comparative Analysis (QCA) to analyze case study and quantitative data collected during the evaluation of the Communities Putting Prevention to Work (CPPW) program. Setting CPPW awardee program staff and partners implemented evidence-based public health improvements in counties, cities, and organizations (eg, worksites, schools). Participants Data came from case studies of 22 CPPW awardee programs that implemented evidence-based, community-and organizational-level public health improvements. Intervention Program staff implemented a range of evidence-based public health improvements related to tobacco control and obesity prevention. Main Outcome Measure The outcome measure was completion of approximately 60% of work plan objectives. Results Analysis of the capacity conditions revealed 2 combinations for completing most work plan objectives: (1) having experience implementing public health improvements in combination with having a history of collaboration with partners; and (2) not having experience implementing public health improvements in combination with having leadership support. Conclusion Awardees have varying levels of capacity. The combinations identified in this analysis provide important insights into how awardees with different combinations of elements of capacity achieved most of their work plan objectives. Even when awardees lack some elements of capacity, they can build it through strategies such as hiring staff and engaging new partners with expertise. In some instances, lacking 1 or more elements of capacity did not prevent an awardee from successfully completing objectives. Implications for Policy & Practice These findings can help funders and practitioners recognize and assemble different aspects of capacity to achieve more successful programs; awardees can draw on extant organizational strengths to compensate when other aspects of capacity are absent. PMID:27598714

  18. Quenching of Particle-Gas Combustible Mixtures Using Electric Particulate Suspension (EPS) and Dispersion Methods

    NASA Technical Reports Server (NTRS)

    Colver, Gerald M.; Goroshin, Samuel; Lee, John H. S.

    2001-01-01

    A cooperative study is being carried out between Iowa State University and McGill University. The new study concerns wall and particle quenching effects in particle-gas mixtures. The primary objective is to measure and interpret flame quenching distances, flammability limits, and burning velocities in particulate suspensions. A secondary objective is to measure particle slip velocities and particle velocity distribution as these influence flame propagation. Two suspension techniques will be utilized and compared: (1) electric particle suspension/EPS; and (2) flow dispersion. Microgravity tests will permit testing of larger particles and higher and more uniform dust concentrations than is possible in normal gravity.

  19. The shape of novel objects contributes to shared impressions.

    PubMed

    Kurosu, Aaron; Todorov, Alexander

    2017-11-01

    How do people share impressions of novel objects, and is this even possible? We tested whether the shape of novel 3-D objects can lead to similar impressions across people. To do this, we introduced a technique for manipulating highly complex shapes and measured four types of evaluative impressions (approachable, dangerous, beautiful, likable). Because relatively little is understood regarding how people form impressions of novel objects, we first sought to confirm the reliability of this behavior by examining how similar impressions are for an individual asked to re-evaluate the stimuli (i.e., impression consistency). To situate the magnitude of reliability, we compared novel objects to faces-familiar and extensively studied stimuli. Impression consistency was always present for both types of stimuli and comparable across all evaluations. Second, and more importantly, we tested how similar impressions are across people (i.e., impression consensus). Impression consensus was always present for faces, but not always for novel objects. In Study 2 we examined a greater diversity of shapes and replicated the findings of Study 1 for novel objects. The findings suggest that impression consensus for novel objects only emerges when certain types of shapes and evaluations map together. When such mapping is possible, impressions are isomorphic with the parametrized shapes.

  20. Setup calibration and optimization for comparative digital holography

    NASA Astrophysics Data System (ADS)

    Baumbach, Torsten; Osten, Wolfgang; Kebbel, Volker; von Kopylow, Christoph; Jueptner, Werner

    2004-08-01

    With increasing globalization many enterprises decide to produce the components of their products at different locations all over the world. Consequently, new technologies and strategies for quality control are required. In this context the remote comparison of objects with regard to their shape or response on certain loads is getting more and more important for a variety of applications. For such a task the novel method of comparative digital holography is a suitable tool with interferometric sensitivity. With this technique the comparison in shape or deformation of two objects does not require the presence of both objects at the same place. In contrast to the well known incoherent techniques based on inverse fringe projection this new approach uses a coherent mask for the illumination of the sample object. The coherent mask is created by digital holography to enable the instant access to the complete optical information of the master object at any wanted place. The reconstruction of the mask is done by a spatial light modulator (SLM). The transmission of the digital master hologram to the place of comparison can be done via digital telecommunication networks. Contrary to other interferometric techniques this method enables the comparison of objects with different microstructure. In continuation of earlier reports our investigations are focused here on the analysis of the constraints of the setup with respect to the quality of the hologram reconstruction with a spatial light modulator. For successful measurements the selection of the appropriate reconstruction method and the adequate optical set-up is mandatory. In addition, the use of a SLM for the reconstruction requires the knowledge of its properties for the accomplishment of this method. The investigation results for the display properties such as display curvature, phase shift and the consequences for the technique will be presented. The optimization and the calibration of the set-up and its components lead to improved results in comparative digital holography with respect to the resolution. Examples of measurements before and after the optimization and calibration will be presented.

  1. Perirhinal cortical inactivation impairs object-in-place memory and disrupts task-dependent firing in hippocampal CA1, but not in CA3.

    PubMed

    Lee, Inah; Park, Seong-Beom

    2013-01-01

    Objects and their locations can associatively define an event and a conjoint representation of object-place can form an event memory. Remembering how to respond to a certain object in a spatial context is dependent on both hippocampus and perirhinal cortex (PER). However, the relative functional contributions of the two regions are largely unknown in object-place associative memory. We investigated the PER influence on hippocampal firing in a goal-directed object-place memory task by comparing the firing patterns of CA1 and CA3 of the dorsal hippocampus between conditions of PER muscimol inactivation and vehicle control infusions. Rats were required to choose one of the two objects in a specific spatial context (regardless of the object positions in the context), which was shown to be dependent on both hippocampus and PER. Inactivation of PER with muscimol (MUS) severely disrupted performance of well-trained rats, resulting in response bias (i.e., choosing any object on a particular side). MUS did not significantly alter the baseline firing rates of hippocampal neurons. We measured the similarity in firing patterns between two trial conditions in which the same target objects were chosen on opposite sides within the same arm [object-in-place (O-P) strategy] and compared the results with the similarity in firing between two trial conditions in which the rat chose any object encountered on a particular side [response-in-place (R-P) strategy]. We found that the similarity in firing patterns for O-P trials was significantly reduced with MUS compared to control conditions (CTs). Importantly, this was largely because MUS injections affected the O-P firing patterns in CA1 neurons, but not in CA3. The results suggest that PER is critical for goal-directed organization of object-place associative memory in the hippocampus presumably by influencing how object information is associated with spatial information in CA1 according to task demand.

  2. Surface radiation dose comparison of a dedicated extremity cone beam computed tomography (CBCT) device and a multidetector computed tomography (MDCT) machine in pediatric ankle and wrist phantoms

    PubMed Central

    Nagy, Eszter; Apfaltrer, Georg; Riccabona, Michael; Singer, Georg; Stücklschweiger, Georg; Guss, Helmuth; Sorantin, Erich

    2017-01-01

    Objectives To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. Methods Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. Results Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). Conclusions Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications. PMID:28570626

  3. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools.

    PubMed

    Byun, Wonwoo; Blair, Steven N; Pate, Russell R

    2013-01-03

    This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as <200 counts/15-second. The accelerometry data were summarized into the average minutes per hour spent in sedentary behavior during the in-school, the after-school, and the total-day period. Mixed linear regression models were used to determine differences in the average time spent in sedentary behavior between children attending traditional and Montessori preschools, after adjusting for selected potential correlates of preschoolers' sedentary behavior. Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03), after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04), and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009) periods. School type (Montessori or traditional), preschool setting (private or public), socio-demographic factors (age, gender, and socioeconomic status) were found to be significant predictors of preschoolers' sedentary behavior. Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools.

  4. The effects of energy drink in combination with alcohol on performance and subjective awareness.

    PubMed

    Alford, Chris; Hamilton-Morris, Jennifer; Verster, Joris C

    2012-08-01

    This study investigated the coadministration of an energy drink with alcohol to study the effects on subjective intoxication and objective performance. This study aims to evaluate the objective and subjective effects of alcohol versus placebo at two alcohol doses, alone and in combination with an energy drink, in a balanced order, placebo-controlled, double-blind design. Two groups of ten healthy volunteers, mean (SD) age of 24 (6.5), participated in the study. One group consumed energy drink containing 80 mg of caffeine and the other consumed a placebo drink, with both receiving two alcohol doses (0.046 and 0.087% breathalyser alcohol concentration). Tests included breath alcohol assessment, objective measures of performance (reaction time, word memory and Stroop task) and subjective visual analogue mood scales. Participants showed significantly impaired reaction time and memory after alcohol compared to the no alcohol condition and had poorer memory after the higher alcohol dose. Stroop performance was improved with the energy drink plus alcohol combination compared to the placebo drink plus alcohol combination. Participants felt significant subjective dose-related impairment after alcohol compared to no alcohol. Neither breath alcohol concentration nor the subjective measures showed a significant difference between the energy drink and the placebo energy drink when combined with alcohol. Subjective effects reflected awareness of alcohol intoxication and sensitivity to increasing alcohol dose. There were no overall significant group differences for subjective measures between energy drink and placebo groups in the presence of alcohol and no evidence that the energy drink masked the subjective effects of alcohol at either dose.

  5. 3D reconstruction optimization using imagery captured by unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Bassie, Abby L.; Meacham, Sean; Young, David; Turnage, Gray; Moorhead, Robert J.

    2017-05-01

    Because unmanned air vehicles (UAVs) are emerging as an indispensable image acquisition platform in precision agriculture, it is vitally important that researchers understand how to optimize UAV camera payloads for analysis of surveyed areas. In this study, imagery captured by a Nikon RGB camera attached to a Precision Hawk Lancaster was used to survey an agricultural field from six different altitudes ranging from 45.72 m (150 ft.) to 121.92 m (400 ft.). After collecting imagery, two different software packages (MeshLab and AgiSoft) were used to measure predetermined reference objects within six three-dimensional (3-D) point clouds (one per altitude scenario). In-silico measurements were then compared to actual reference object measurements, as recorded with a tape measure. Deviations of in-silico measurements from actual measurements were recorded as Δx, Δy, and Δz. The average measurement deviation in each coordinate direction was then calculated for each of the six flight scenarios. Results from MeshLab vs. AgiSoft offered insight into the effectiveness of GPS-defined point cloud scaling in comparison to user-defined point cloud scaling. In three of the six flight scenarios flown, MeshLab's 3D imaging software (user-defined scale) was able to measure object dimensions from 50.8 to 76.2 cm (20-30 inches) with greater than 93% accuracy. The largest average deviation in any flight scenario from actual measurements was 14.77 cm (5.82 in.). Analysis of the point clouds in AgiSoft (GPS-defined scale) yielded even smaller Δx, Δy, and Δz than the MeshLab measurements in over 75% of the flight scenarios. The precisions of these results are satisfactory in a wide variety of precision agriculture applications focused on differentiating and identifying objects using remote imagery.

  6. Objectively measured physical activity has a negative but weak association with academic performance in children and adolescents.

    PubMed

    Esteban-Cornejo, Irene; Tejero-González, Carlos M; Martinez-Gomez, David; Cabanas-Sánchez, Verónica; Fernández-Santos, Jorge R; Conde-Caveda, Julio; Sallis, James F; Veiga, Oscar L

    2014-11-01

    There is an emerging body of evidence on the potential effects of regular physical activity on academic performance. The aim of this study was to add to the debate, by examining the association between objectively measured physical activity and academic performance in a relatively large sample of children and adolescents. The Spanish UP & DOWN study is a 3-year longitudinal study designed to assess the impact, overtime, of physical activity and sedentary behaviours on health indicators. This present analysis was conducted with 1778 children and adolescents aged 6-18 years. Physical activity was objectively measured by accelerometry. Academic performance was assessed using school grades. Physical activity was inversely associated with all academic performance indicators after adjustment for potential confounders, including neonatal variables, fatness and fitness (all p < 0.05). This association became nonsignificant among quartiles of physical activity. There were only slight differences in academic performance between the lowest and the second quartile of physical activity, compared to the highest quartile, with very small effect size (d < 0.20). Objectively measured physical activity may influence academic performance during both childhood and adolescence, but this association was negative and very weak. Longitudinal and intervention studies are necessary to further our understanding. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  7. ConvPhot: A profile-matching algorithm for precision photometry

    NASA Astrophysics Data System (ADS)

    De Santis, C.; Grazian, A.; Fontana, A.; Santini, P.

    2007-02-01

    We describe in this paper a new, public software for accurate "PSF-matched" multiband photometry for images of different resolution and depth, that we have named ConvPhot, of which we analyse performances and limitations. It is designed to work when a high resolution image is available to identify and extract the objects, and colours or variations in luminosity are to be measured in another image of lower resolution but comparable depth. To maximise the usability of this software, we explicitly use the outputs of the popular SExtractor code that is used to extract all objects from the high resolution "detection" image. The technique adopted by the code is essentially to convolve each object to the PSF of the lower resolution "measure" image, and to obtain the flux of each object by a global χ2 minimisation on such measure image. We remark that no a priori assumption is done on the shape of the objects. In this paper we provide a full description of the algorithm, a discussion of the possible systematic effects involved and the results of a set of simulations and validation tests that we have performed on real as well as simulated images. The source code of ConvPhot, written in C language under the GNU Public License, is released worldwide.

  8. The Reliability and Concurrent Validity of the Figure-of-Eight Method of Measuring Hand Edema in Patients with Burns

    DTIC Science & Technology

    2007-02-01

    Travis L. Hedman, MPT, OCS, Ted T. Chapman, OTR/L, Steven E. Wolf, MD, FACS, John B. Holcomb, MD, FACS Objective: Water volumetry is considered the...hand, using the figure-of-eight technique. A third tester per- formed two measurements, using water volumetry . An independent investigator recorded...all measurements. Intratester and intertester reliability were analyzed. Concurrent validity was examined and compared with water volumetry

  9. Creating objective and measurable postgraduate year 1 residency graduation requirements.

    PubMed

    Starosta, Kaitlin; Davis, Susan L; Kenney, Rachel M; Peters, Michael; To, Long; Kalus, James S

    2017-03-15

    The process of developing objective and measurable postgraduate year 1 (PGY1) residency graduation requirements and a progress tracking system is described. The PGY1 residency accreditation standard requires that programs establish criteria that must be met by residents for successful completion of the program (i.e., graduation requirements), which should presumably be aligned with helping residents to achieve the purpose of residency training. In addition, programs must track a resident's progress toward fulfillment of residency goals and objectives. Defining graduation requirements and establishing the process for tracking residents' progress are left up to the discretion of the residency program. To help standardize resident performance assessments, leaders of an academic medical center-based PGY1 residency program developed graduation requirement criteria that are objective, measurable, and linked back to residency goals and objectives. A system for tracking resident progress relative to quarterly progress targets was instituted. Leaders also developed a focused, on-the-spot skills assessment termed "the Thunderdome," which was designed for objective evaluation of direct patient care skills. Quarterly data on residents' progress are used to update and customize each resident's training plan. Implementation of this system allowed seamless linkage of the training plan, the progress tracking system, and the specified graduation requirement criteria. PGY1 residency requirements that are objective, that are measurable, and that attempt to identify what skills the resident must demonstrate in order to graduate from the program were developed for use in our residency program. A system for tracking the residents' progress by comparing residents' performance to predetermined quarterly benchmarks was developed. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  10. Early Detection of Autism Spectrum Disorder in Young isiZulu-Speaking Children in South Africa

    ERIC Educational Resources Information Center

    Chambers, Nola J.; Wetherby, Amy M.; Stronach, Sheri T.; Njongwe, Nonyameko; Kauchali, Shuaib; Grinker, Richard R.

    2017-01-01

    Culturally appropriate tools are needed for detecting symptoms of autism spectrum disorder in young South African children. The objectives of this study were to (1) adapt and translate into isiZulu existing measures for detecting early signs of autism spectrum disorder, (2) use the measures to characterize and compare behavioural profiles of young…

  11. Evaluating Journal Quality: Is the H-Index a Better Measure than Impact Factors?

    ERIC Educational Resources Information Center

    Hodge, David R.; Lacasse, Jeffrey R.

    2011-01-01

    Objectives: This study evaluates the utility of a new measure--the h-index--that may provide a more valid approach to evaluating journal quality in the social work profession. Method: H-index values are compared with Thomson ISI 5-year impact factors and expert opinion. Results: As hypothesized, the h-index correlates highly with ISI 5-year impact…

  12. The SWAN Captures Variance at the Negative and Positive Ends of the ADHD Symptom Dimension

    ERIC Educational Resources Information Center

    Arnett, Anne B.; Pennington, Bruce F.; Friend, Angela; Willcutt, Erik G.; Byrne, Brian; Samuelsson, Stefan; Olson, Richard K.

    2013-01-01

    Objective: The Strengths and Weaknesses of ADHD Symptoms and Normal Behavior (SWAN) Rating Scale differs from previous parent reports of ADHD in that it was designed to also measure variability at the positive end of the symptom spectrum. Method: The psychometric properties of the SWAN were tested and compared with an established measure of ADHD,…

  13. Electrochemical corrosion studies

    NASA Technical Reports Server (NTRS)

    Knockemus, W. W.

    1986-01-01

    The objective was to gain familiarity with the Model 350 Corrosion Measurement Console, to determine if metal protection by grease coatings can be measured by the polarization-resistance method, and to compare corrosion rates of 4130 steel coated with various greases. Results show that grease protection of steel may be determined electrochemically. Studies were also conducted to determine the effectiveness of certain corrosion inhibitors on aluminum and steel.

  14. Behavioral and Cardiovascular Responses to Frustration during Simulated Driving Tasks in Young Adults with and without Attention Disorder Symptoms

    ERIC Educational Resources Information Center

    Oliver, Michele L.; Nigg, Joel T.; Cassavaugh, Nicholas D.; Backs, Richard W.

    2012-01-01

    Objective: The present study examined the role of negative emotions on driving performance in relation to ADHD, by comparing young adults scoring high on measures of ADHD (n = 20) with a control group (n = 22). Method: The authors used cardiorespiratory physiological measures, simulated driving behavior, and self-report to examine how participants…

  15. How to compare movement? A review of physical movement similarity measures in geographic information science and beyond.

    PubMed

    Ranacher, Peter; Tzavella, Katerina

    2014-05-27

    In geographic information science, a plethora of different approaches and methods is used to assess the similarity of movement. Some of these approaches term two moving objects similar if they share akin paths. Others require objects to move at similar speed and yet others consider movement similar if it occurs at the same time. We believe that a structured and comprehensive classification of movement comparison measures is missing. We argue that such a classification not only depicts the status quo of qualitative and quantitative movement analysis, but also allows for identifying those aspects of movement for which similarity measures are scarce or entirely missing. In this review paper we, first, decompose movement into its spatial, temporal, and spatiotemporal movement parameters. A movement parameter is a physical quantity of movement, such as speed, spatial path, or temporal duration. For each of these parameters we then review qualitative and quantitative methods of how to compare movement. Thus, we provide a systematic and comprehensive classification of different movement similarity measures used in geographic information science. This classification is a valuable first step toward a GIS toolbox comprising all relevant movement comparison methods.

  16. Visual- and Vestibular-Autonomic Influence on Short-Term Cardiovascular Regulatory Mechanisms

    NASA Technical Reports Server (NTRS)

    Mullen, Thomas J.; Ramsdell, Craig D.

    1999-01-01

    This synergy project was a one-year effort conducted cooperatively by members of the NSBRI Cardiovascular Alterations and Neurovestibular Adaptation Teams in collaboration with NASA Johnson Space Center (JSC) colleagues. The objective of this study was to evaluate visual autonomic interactions on short-term cardiovascular regulatory mechanisms. Based on established visual-vestibular and vestibular-autonomic shared neural pathways, we hypothesized that visually induced changes in orientation will trigger autonomic cardiovascular reflexes. A second objective was to compare baroreflex changes during postural changes as measured with the new Cardiovascular System Identification (CSI) technique with those measured using a neck barocuff. While the neck barocuff stimulates only the carotid baroreceptors, CSI provides a measure of overall baroreflex responsiveness. This study involved a repeated measures design with 16 healthy human subjects (8 M, 8 F) to examine cardiovascular regulatory responses during actual and virtual head-upright tilts. Baroreflex sensitivity was first evaluated with subjects in supine and upright positions during actual tilt-table testing using both neck barocuff and CSI methods. The responses to actual tilts during this first session were then compared to responses during visually induced tilt and/or rotation obtained during a second session.

  17. How to compare movement? A review of physical movement similarity measures in geographic information science and beyond

    PubMed Central

    Ranacher, Peter; Tzavella, Katerina

    2014-01-01

    In geographic information science, a plethora of different approaches and methods is used to assess the similarity of movement. Some of these approaches term two moving objects similar if they share akin paths. Others require objects to move at similar speed and yet others consider movement similar if it occurs at the same time. We believe that a structured and comprehensive classification of movement comparison measures is missing. We argue that such a classification not only depicts the status quo of qualitative and quantitative movement analysis, but also allows for identifying those aspects of movement for which similarity measures are scarce or entirely missing. In this review paper we, first, decompose movement into its spatial, temporal, and spatiotemporal movement parameters. A movement parameter is a physical quantity of movement, such as speed, spatial path, or temporal duration. For each of these parameters we then review qualitative and quantitative methods of how to compare movement. Thus, we provide a systematic and comprehensive classification of different movement similarity measures used in geographic information science. This classification is a valuable first step toward a GIS toolbox comprising all relevant movement comparison methods. PMID:27019646

  18. Long-term evaluation of posterior lateral meniscus root tears left in situ at the time of anterior cruciate ligament reconstruction.

    PubMed

    Shelbourne, K Donald; Roberson, Troy A; Gray, Tinker

    2011-07-01

    The long-term radiographic and subjective results of patients with posterior lateral meniscus root tears left in situ at the time of anterior cruciate ligament reconstruction has not been reported. The authors hypothesized that patients who had posterior lateral meniscus root tears left in situ would have statistically significantly lower subjective scores and greater joint-space narrowing as compared with a control group. Cohort study; Level of evidence, 3. Thirty-three patients who had isolated posterior lateral meniscus root tear and >5 years objective and subjective follow-up were evaluated and compared with a matched control group without meniscal tears based on sex, chronicity of tear, age, and follow-up time. Patients were evaluated subjectively and objectively using the International Knee Documentation Committee criteria. The mean objective follow-up time was 10.6 ± 4.5 years. The mean subjective total score was 84.6 ± 14 in the study group versus 90.5 ± 13 in the control group (P = .09). Radiographs showed lateral joint-space narrowing rated as normal in 19, mild in 10, moderate in 3, and severe in 1 versus the control group, which was normal in 28 and mild in 5 patients. The measured amount of lateral joint-space narrowing compared with the other knee was 1.0 ± 1.6 mm in the study group versus 0 ± 1.1 mm in the controls on 45° flexed posteroanterior radiographs (P < .006). At a mean of 10 years' follow-up of posterior lateral meniscus root tears left in situ, mild lateral joint-space narrowing was measured without significant differences in subjective or objective scores compared with controls. This study provides a baseline that can be used to compare the results of procedures used to treat these tears in other manners.

  19. Behind the Final Grade in Hybrid v. Traditional Courses: Comparing Student Performance by Assessment Type, Core Competency, and Course Objective

    ERIC Educational Resources Information Center

    Bain, Lisa Z.

    2012-01-01

    There are many different delivery methods used by institutions of higher education. These include traditional, hybrid, and online course offerings. The comparisons of these typically use final grade as the measure of student performance. This research study looks behind the final grade and compares student performance by assessment type, core…

  20. A Contrast between Mothers' Assessments of Child Malnutrition and Physical Anthropometry in Rural Mexico: A Mixed Methods Community Study

    ERIC Educational Resources Information Center

    Turnbull, Bernardo; Martinez-Andrade, Gloria; Huerfano, Nazly; Ryan, Gery W.; Martinez, Homero

    2009-01-01

    Objective: To compare mothers' assessments of nutritional status with anthropometric measures and gain further insights into mothers' reasons for their judgment. Design: Each mother was asked to assess the nutritional status of her child and 2 other children and to compare all 3. Rates for "hits" and "misses" between mothers'…

  1. Facial Expression of Affect in Children with Cornelia de Lange Syndrome

    ERIC Educational Resources Information Center

    Collis, L.; Moss, J.; Jutley, J.; Cornish, K.; Oliver, C.

    2008-01-01

    Background: Individuals with Cornelia de Lange syndrome (CdLS) have been reported to show comparatively high levels of flat and negative affect but there have been no empirical evaluations. In this study, we use an objective measure of facial expression to compare affect in CdLS with that seen in Cri du Chat syndrome (CDC) and a group of…

  2. Multi-Objective vs. Single Objective Calibration of a Hydrologic Model using Either Different Hydrologic Signatures or Complementary Data Sources

    NASA Astrophysics Data System (ADS)

    Mai, J.; Cuntz, M.; Zink, M.; Schaefer, D.; Thober, S.; Samaniego, L. E.; Shafii, M.; Tolson, B.

    2015-12-01

    Hydrologic models are traditionally calibrated against discharge. Recent studies have shown however, that only a few global model parameters are constrained using the integral discharge measurements. It is therefore advisable to use additional information to calibrate those models. Snow pack data, for example, could improve the parametrization of snow-related processes, which might be underrepresented when using only discharge. One common approach is to combine these multiple objectives into one single objective function and allow the use of a single-objective algorithm. Another strategy is to consider the different objectives separately and apply a Pareto-optimizing algorithm. Both methods are challenging in the choice of appropriate multiple objectives with either conflicting interests or the focus on different model processes. A first aim of this study is to compare the two approaches employing the mesoscale Hydrologic Model mHM at several distinct river basins over Europe and North America. This comparison will allow the identification of the single-objective solution on the Pareto front. It is elucidated if this position is determined by the weighting and scaling of the multiple objectives when combing them to the single objective. The principal second aim is to guide the selection of proper objectives employing sensitivity analyses. These analyses are used to determine if an additional information would help to constrain additional model parameters. The additional information are either multiple data sources or multiple signatures of one measurement. It is evaluated if specific discharge signatures can inform different parts of the hydrologic model. The results show that an appropriate selection of discharge signatures increased the number of constrained parameters by more than 50% compared to using only NSE of the discharge time series. It is further assessed if the use of these signatures impose conflicting objectives on the hydrologic model. The usage of signatures is furthermore contrasted to the use of additional observations such as soil moisture or snow height. The gain of using an auxiliary dataset is determined using the parametric sensitivity on the respective modeled variable.

  3. The use of Peer Optic Nerve Photographs for Teaching Direct Ophthalmoscopy

    PubMed Central

    Milani, Behrad Y.; Majdi, Mercede N.; Green, Wesley; Mehralian, Amir; Moarefi, Majid; Oh, Freddie S.; Riddle, Janet M.; Djalilian, Ali R.

    2014-01-01

    Objective To use a novel teaching exercise to encourage students to practice ophthalmoscopy and to measure the learning effect both subjectively and objectively. Design Comparative case series. Participants One-hundred thirty-one fourth-year medical students on their one-week ophthalmology rotations with 89 in the experimental group and 42 in the control group. Methods Those in the experimental group had one eye dilated and their optic nerve photographed on the first day. The next day, these students received an unlabeled optic nerve photograph belonging to one of their peers (typically 8–10 per group) and were given three days to identify the student matching the photograph. The students in the control group were simply encouraged to practice ophthalmoscopy on each other without the use of photographs. Main Outcome Measures Both objective and subjective changes from the beginning to the end of the rotation were measured and compared between the two groups. Results In the 89 students who used peer optic nerve photographs, 75 (84.3%) showed improvement in direct ophthalmoscopy skills over the course of the week. In contrast, only 12 (28.6%) of the 42 control students demonstrated an objective improvement (P < 0.001). The subjective confidence levels were likewise more improved in the students who took part in the optic nerve photograph exercise. Conclusions These results suggest that the task of matching an unknown optic nerve photograph to the correct eye of a peer leads to increased self-confidence and more proficient use of the direct ophthalmoscope. PMID:23246117

  4. The effect of local cryotherapy on subjective and objective recovery characteristics following an exhaustive jump protocol

    PubMed Central

    Hohenauer, Erich; Clarys, Peter; Baeyens, Jean-Pierre; Clijsen, Ron

    2016-01-01

    The purpose of this controlled trial was to investigate the effects of a single local cryotherapy session on the recovery characteristics over a period of 72 hours. Twenty-two young and healthy female (n=17; mean age: 21.9±1.1 years) and male (n=5;mean age: 25.4±2.8 years) adults participated in this study. Following an exhaustive jump protocol (3×30 countermovement jumps), half of the participants received either a single local cryotherapy application (+8°C) or a single local thermoneutral application (+32°C) of 20-minute duration using two thigh cuffs. Subjective measures of recovery (delayed-onset muscle soreness and ratings of perceived exertion) and objective measures of recovery (vertical jump performance and peak power output) were assessed immediately following the postexercise applications (0 hours) and at 24 hours, 48 hours, and 72 hours after the jump protocol. Local cryotherapy failed to significantly affect any subjective recovery variable during the 72-hour recovery period (P>0.05). After 72 hours, the ratings of perceived exertion were significantly lower in the thermoneutral group compared to that in the cryotherapy group (P=0.002). No significant differences were observed between the cryotherapy and the thermoneutral groups with respect to any of the objective recovery variables. In this experimental study, a 20-minute cryotherapy cuff application failed to demonstrate a positive effect on any objective measures of recovery. The effects of local thermoneutral application on subjective recovery characteristics were superior when compared to the effects of local cryotherapy application at 72 hours postapplication. PMID:27579000

  5. The effect of local cryotherapy on subjective and objective recovery characteristics following an exhaustive jump protocol.

    PubMed

    Hohenauer, Erich; Clarys, Peter; Baeyens, Jean-Pierre; Clijsen, Ron

    2016-01-01

    The purpose of this controlled trial was to investigate the effects of a single local cryotherapy session on the recovery characteristics over a period of 72 hours. Twenty-two young and healthy female (n=17; mean age: 21.9±1.1 years) and male (n=5;mean age: 25.4±2.8 years) adults participated in this study. Following an exhaustive jump protocol (3×30 countermovement jumps), half of the participants received either a single local cryotherapy application (+8°C) or a single local thermoneutral application (+32°C) of 20-minute duration using two thigh cuffs. Subjective measures of recovery (delayed-onset muscle soreness and ratings of perceived exertion) and objective measures of recovery (vertical jump performance and peak power output) were assessed immediately following the postexercise applications (0 hours) and at 24 hours, 48 hours, and 72 hours after the jump protocol. Local cryotherapy failed to significantly affect any subjective recovery variable during the 72-hour recovery period (P>0.05). After 72 hours, the ratings of perceived exertion were significantly lower in the thermoneutral group compared to that in the cryotherapy group (P=0.002). No significant differences were observed between the cryotherapy and the thermoneutral groups with respect to any of the objective recovery variables. In this experimental study, a 20-minute cryotherapy cuff application failed to demonstrate a positive effect on any objective measures of recovery. The effects of local thermoneutral application on subjective recovery characteristics were superior when compared to the effects of local cryotherapy application at 72 hours postapplication.

  6. Assessment of satisfaction and Quality of Life using self - reported questionnaires after urethroplasty: a prospective analysis

    PubMed Central

    Lucas, Eduardo Terra; Koff, Walter José; Rosito, Tiago Elias; Berger, Milton; Bortolini, Tiago; Silva, Brasil

    2017-01-01

    ABSTRACT Objectives To assess patient satisfaction and quality of life after urethroplasty using two different self-reported outcome measures and to compare it with objective clinical data. Materials and Methods We prospectively collected data from 35 consecutive patients who underwent urethroplasty from January 2013 to September 2014. Patient demographics, International Prostate Symptom Score (IPSS), quality of life score, urethral stricture surgery patient-reported outcome measure (USS-PROM), maximum flow rate (Qmax) and post-void residual urine were collected before, two and eight months after surgery. Failure occurred when any postoperative instrumentation was performed. General estimation equation was used to compare the results and linear regression analysis to correlate both questionnaires with objective data. Results Mean age was 61 years. Urethroplasties were equally divided between anastomotic and buccal mucosa grafts and 19 patients (59.3%) had a previous urethral procedure. Overall success rate was 87.5%. IPSS improved from a mean 19 at baseline to 5.32 at 8 months (p <0.001). The mean USS-PROM score also improved from 13.21 preoperatively to 3.36 after surgery (p <0.001) and 84.3% of patients were satisfied or very satisfied with surgical results. Mean Qmax increased from 4.64mL/s to 11mL/s (p <0.001). Strong negative correlation was found respectively between flow rate and USS-PROM (r=-0.531, p <0.001) and with IPSS (r=-0.512, p <0.001). Conclusions Significant improvements in urinary symptoms and in quality of life are expected after urethroplasty and they are correlated with objective measures. PMID:28128915

  7. Objective Measures of Emotion Related to Brand Attitude: A New Way to Quantify Emotion-Related Aspects Relevant to Marketing

    PubMed Central

    Walla, Peter; Brenner, Gerhard; Koller, Monika

    2011-01-01

    With this study we wanted to test the hypothesis that individual like and dislike as occurring in relation to brand attitude can be objectively assessed. First, individuals rated common brands with respect to subjective preference. Then, they volunteered in an experiment during which their most liked and disliked brand names were visually presented while three different objective measures were taken. Participant's eye blinks as responses to acoustic startle probes were registered with electromyography (EMG) (i) and their skin conductance (ii) and their heart rate (iii) were recorded. We found significantly reduced eye blink amplitudes related to liked brand names compared to disliked brand names. This finding suggests that visual perception of liked brand names elicits higher degrees of pleasantness, more positive emotion and approach-oriented motivation than visual perception of disliked brand names. Also, skin conductance and heart rate were both reduced in case of liked versus disliked brand names. We conclude that all our physiological measures highlight emotion-related differences depending on the like and dislike toward individual brands. We suggest that objective measures should be used more frequently to quantify emotion-related aspects of brand attitude. In particular, there might be potential interest to introduce startle reflex modulation to measure emotion-related impact during product development, product design and various further fields relevant to marketing. Our findings are discussed in relation to the idea that self reported measures are most often cognitively polluted. PMID:22073192

  8. Immersion in Cold-Water Evaluation (ICE) and self-reported cold intolerance are reliable but unrelated measures.

    PubMed

    Traynor, Robyn; MacDermid, Joy C

    2008-09-01

    Intolerance to the cold is common following peripheral nerve injury and surgery of the upper extremity. Despite its prevalence, the exact pathophysiology and natural history of this condition are not well understood. Subjective, self-report questionnaires have been created and validated as reliable measures of post-traumatic cold intolerance. The difficulty currently lies in assigning an objective measure to this predominantly subjective phenomenon. The present study evaluated the test-retest reliability of a proposed objective measure of cold intolerance, the Immersion in Cold-water Evaluation (ICE), and its correlation with subjective measures in healthy control subjects. Two age groups were also compared to investigate the effect of age on cold intolerance and temperature recovery. On two separate testing days, subjects completed three health-related questionnaires and submersed their dominant hands in cold water. The temperature of their second and fifth digits was monitored during recovery. Both the objective cold-provocation testing and the subjective self-report questionnaires were highly reliable albeit not significantly correlated. No significant temperature recovery trend was noted between the age groups. Post-traumatic cold intolerance is postulated to have both a vascular and neural etiology among other contributing causes. The protocol studied here was centered predominantly on the former etiology, examining peripheral blood flow and associated temperature recovery. This study established ICE as a reliable means to objectively measure cold response, supplementing information provided by previously validated self-report methods.

  9. Objective measures of emotion related to brand attitude: a new way to quantify emotion-related aspects relevant to marketing.

    PubMed

    Walla, Peter; Brenner, Gerhard; Koller, Monika

    2011-01-01

    With this study we wanted to test the hypothesis that individual like and dislike as occurring in relation to brand attitude can be objectively assessed. First, individuals rated common brands with respect to subjective preference. Then, they volunteered in an experiment during which their most liked and disliked brand names were visually presented while three different objective measures were taken. Participant's eye blinks as responses to acoustic startle probes were registered with electromyography (EMG) (i) and their skin conductance (ii) and their heart rate (iii) were recorded. We found significantly reduced eye blink amplitudes related to liked brand names compared to disliked brand names. This finding suggests that visual perception of liked brand names elicits higher degrees of pleasantness, more positive emotion and approach-oriented motivation than visual perception of disliked brand names. Also, skin conductance and heart rate were both reduced in case of liked versus disliked brand names. We conclude that all our physiological measures highlight emotion-related differences depending on the like and dislike toward individual brands. We suggest that objective measures should be used more frequently to quantify emotion-related aspects of brand attitude. In particular, there might be potential interest to introduce startle reflex modulation to measure emotion-related impact during product development, product design and various further fields relevant to marketing. Our findings are discussed in relation to the idea that self reported measures are most often cognitively polluted.

  10. An approach for quantitative image quality analysis for CT

    NASA Astrophysics Data System (ADS)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  11. The Late Positive Potential (LPP) in Response to Varying Types of Emotional and Cigarette Stimuli in Smokers: A Content Comparison

    PubMed Central

    Minnix, Jennifer A.; Versace, Francesco; Robinson, Jason D.; Lam, Cho Y.; Engelmann, Jeffrey M.; Cui, Yong; Brown, Victoria L.; Cinciripini, Paul M.

    2013-01-01

    Identifying neural mechanisms associated with addiction has substantially improved the overall understanding of addictive processes. Indeed, research suggests that drug-associated cues may take advantage of neural mechanisms originally intended for emotional processing of stimuli relevant to survival. In this study, we investigated cortical responses to several categories of emotional cues (erotic, romance, pleasant objects, mutilation, sadness, unpleasant objects) as well as two types of smoking-related cues (people smoking and cigarette-related objects). We recorded ERPs from 180 smokers prior to their participation in a smoking cessation clinical trial and assessed emotional salience by measuring the amplitude of the late positive potential (LPP; 400 to 600 ms after picture onset). As expected, emotional and cigarette-related pictures prompted a significantly larger LPP than neutral pictures. The amplitude of the LPP increased as a function of picture arousal level, with high-arousing erotic and mutilation pictures showing the largest response in contrast to low-arousing pleasant and unpleasant objects, which showed the smallest response (other than neutral). Compared to females, male participants showed larger LPPs for high-arousing erotic and mutilation pictures. However, unlike emotional pictures, no difference was noted for the LPP between cigarette stimuli containing people versus those containing only objects, suggesting that in contrast to emotional objects, cigarette-related objects are highly relevant for smokers. We also compared the smokers to a small (N=40), convenience sample of never-smokers. We found that never-smokers had significantly smaller LPPs in response to erotic and cigarette stimuli containing only objects compared to smokers. PMID:23643564

  12. Perceptual video quality assessment in H.264 video coding standard using objective modeling.

    PubMed

    Karthikeyan, Ramasamy; Sainarayanan, Gopalakrishnan; Deepa, Subramaniam Nachimuthu

    2014-01-01

    Since usage of digital video is wide spread nowadays, quality considerations have become essential, and industry demand for video quality measurement is rising. This proposal provides a method of perceptual quality assessment in H.264 standard encoder using objective modeling. For this purpose, quality impairments are calculated and a model is developed to compute the perceptual video quality metric based on no reference method. Because of the shuttle difference between the original video and the encoded video the quality of the encoded picture gets degraded, this quality difference is introduced by the encoding process like Intra and Inter prediction. The proposed model takes into account of the artifacts introduced by these spatial and temporal activities in the hybrid block based coding methods and an objective modeling of these artifacts into subjective quality estimation is proposed. The proposed model calculates the objective quality metric using subjective impairments; blockiness, blur and jerkiness compared to the existing bitrate only calculation defined in the ITU G 1070 model. The accuracy of the proposed perceptual video quality metrics is compared against popular full reference objective methods as defined by VQEG.

  13. The exploratory behaviour of rats in the hole-board apparatus: Is head-dipping a valid measure of neophilia?

    PubMed Central

    Brown, Gillian R.; Nemes, Christopher

    2008-01-01

    The exploratory behaviour of laboratory rodents is of interest within a number of areas of behavioural pharmacology. However, how best to measure exploratory behaviour in rodents remains a contentious issue. Many unconditioned tests, such as the open field, potentially confound general locomotor activity with exploration. The hole-board apparatus appears to avoid this confound, as head-dipping into holes in the floor is assumed to be a valid measure of the subject's attraction towards novelty (neophilia). This study aimed to investigate whether head-dipping should be considered a valid measure of neophilia by comparing performance of adult male and female Lister hooded rats on the hole-board task (a) over repeated sessions and (b) when novel objects were absent or present underneath the holes. The results show that head-dipping initially decreased across repeated exposures, while time spent in the aversive central area increased. No change in head-dipping was seen in response to objects being placed underneath the holes. Rather than being a measure of neophilia, these results support the hypothesis that head-dipping represents an escape response, which declines as the subject becomes less fearful. These results are compared with previous studies of repeated exposure to other novel environments. PMID:18406075

  14. Subjectively and objectively measured sleep with and without posttraumatic stress disorder and trauma exposure.

    PubMed

    Kobayashi, Ihori; Huntley, Edward; Lavela, Joseph; Mellman, Thomas A

    2012-07-01

    Although reports of sleep disturbances are common among individuals with posttraumatic stress disorder (PTSD), results of polysomnographic (PSG) studies have inconsistently documented abnormalities and have therefore suggested "sleep state misperception." The authors' study objectives were to compare sleep parameters measured objectively and subjectively in the laboratory and at home in civilians with and without trauma exposure and PTSD. Cross-sectional study. PSG recordings in a sleep laboratory and actigraphic recordings in participants' homes. One hundred three urban-residing African Americans with and without trauma exposure and PTSD who participated in a larger study. N/A. Sleep parameters (total sleep time [TST], sleep onset latency [SOL], and wake after sleep onset [WASO]) were assessed using laboratory PSG and home actigraphy. A sleep diary was completed in the morning after PSG and actigraphy recordings. Habitual TST, SOL, and WASO were assessed using a sleep questionnaire. The Clinician Administered PTSD Scale was administered to assess participants' trauma exposure and PTSD diagnostic status. Participants, regardless of their trauma exposure/PTSD status, underestimated WASO in the diary and questionnaire relative to actigraphy and overestimated SOL in the diary relative to PSG. Among participants with current PTSD, TST diary estimates did not differ from the actigraphy measure in contrast with those without current PTSD who overestimated TST. No other significant group differences in discrepancies between subjective and objective sleep measures were found. Discrepancies between subjectively and objectively measured sleep parameters were not associated with trauma exposure or PTSD. This challenges prior assertions that individuals with PTSD overreport their sleep disturbances.

  15. Using rate of divergence as an objective measure to differentiate between voice signal types based on the amount of disorder in the signal

    PubMed Central

    Calawerts, William M; Lin, Liyu; Sprott, JC; Jiang, Jack J

    2016-01-01

    Objective/Hypothesis The purpose of this paper is to introduce rate of divergence as an objective measure to differentiate between the four voice types based on the amount of disorder present in a signal. We hypothesized that rate of divergence would provide an objective measure that can quantify all four voice types. Study Design 150 acoustic voice recordings were randomly selected and analyzed using traditional perturbation, nonlinear, and rate of divergence analysis methods. ty Methods We developed a new parameter, rate of divergence, which uses a modified version of Wolf’s algorithm for calculating Lyapunov exponents of a system. The outcome of this calculation is not a Lyapunov exponent, but rather a description of the divergence of two nearby data points for the next three points in the time series, followed in three time delayed embedding dimensions. This measure was compared to currently existing perturbation and nonlinear dynamic methods of distinguishing between voice signals. Results There was a direct relationship between voice type and rate of divergence. This calculation is especially effective at differentiating between type 3 and type 4 voices (p<0.001), and is equally effective at differentiating type 1, type 2, and type 3 signals as currently existing methods. Conclusion The rate of divergence calculation introduced is an objective measure that can be used to distinguish between all four voice types based on amount of disorder present, leading to quicker and more accurate voice typing as well as an improved understanding of the nonlinear dynamics involved in phonation. PMID:26920858

  16. A Brief Measure for Assessing Patient Perceptions of Cognitive Side Effects After Electroconvulsive Therapy: The Subjective Assessment of Memory Impairment.

    PubMed

    Kumar, Divya Rani; Han, Hank Ke; Tiller, John; Loo, Colleen K; Martin, Donel M

    2016-12-01

    Directly inquiring about patient experiences of memory problems after ECT may alert clinicians to the existence of treatment side effects and provide an impression of their intrusiveness. In this study, we examined use of a novel and brief patient-reported measure to assess perceptions of memory side effects and their functional consequences before and after an acute ECT treatment course. These outcomes were compared with objective cognitive and subjective quality of life measures. Data for 75 patients who were prescribed an acute course of ECT were analyzed. Subjective and objective measures were assessed before ECT (pretreatment) and at posttreatment. Patient perceptions were assessed using the Subjective Assessment of Memory Impairment, which consists of two items: The Memory Problems item, and The Impact of Cognitive Adverse Events item. Objective cognitive outcomes were assessed using the Montreal Cognitive Assessment. Quality of life was assessed using the Quality of Life Enjoyment and Satisfaction Questionnaire-Short Form. Patient perceptions of their memory problems did not change across the ECT course, and their functional impact were considered less intrusive after ECT. Greater functional impact of memory impairment was related to poorer quality of life at posttreatment, but not at pretreatment. Subjectively rated cognitive functioning was not associated with objective cognitive outcomes. The Subjective Assessment of Memory Impairment is a brief tool for measuring patient-rated memory function. Overall, patients did not report any change in subjective memory problems after ECT. Although perceptions of functional memory impairment and quality of life were related after ECT, there was no association with objectively assessed cognitive outcomes.

  17. Face Validity of the Single Work Ability Item: Comparison with Objectively Measured Heart Rate Reserve over Several Days

    PubMed Central

    Gupta, Nidhi; Jensen, Bjørn Søvsø; Søgaard, Karen; Carneiro, Isabella Gomes; Christiansen, Caroline Stordal; Hanisch, Christiana; Holtermann, Andreas

    2014-01-01

    Purpose: The purpose of this study was to investigate the face validity of the self-reported single item work ability with objectively measured heart rate reserve (%HRR) among blue-collar workers. Methods: We utilized data from 127 blue-collar workers (Female = 53; Male = 74) aged 18–65 years from the cross-sectional “New method for Objective Measurements of physical Activity in Daily living (NOMAD)” study. The workers reported their single item work ability and completed an aerobic capacity cycling test and objective measurements of heart rate reserve monitored with Actiheart for 3–4 days with a total of 5,810 h, including 2,640 working hours. Results: A significant moderate correlation between work ability and %HRR was observed among males (R = −0.33, P = 0.005), but not among females (R = 0.11, P = 0.431). In a gender-stratified multi-adjusted logistic regression analysis, males with high %HRR were more likely to report a reduced work ability compared to males with low %HRR [OR = 4.75, 95% confidence interval (95% CI) = 1.31 to 17.25]. However, this association was not found among females (OR = 0.26, 95% CI 0.03 to 2.16), and a significant interaction between work ability, %HRR and gender was observed (P = 0.03). Conclusions: The observed association between work ability and objectively measured %HRR over several days among male blue-collar workers supports the face validity of the single work ability item. It is a useful and valid measure of the relation between physical work demands and resources among male blue-collar workers. The contrasting association among females needs to be further investigated. PMID:24840350

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heintz, P; Heintz, B; Sandoval, D

    Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. Themore » subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.« less

  19. Fusion of light-field and photogrammetric surface form data

    NASA Astrophysics Data System (ADS)

    Sims-Waterhouse, Danny; Piano, Samanta; Leach, Richard K.

    2017-08-01

    Photogrammetry based systems are able to produce 3D reconstructions of an object given a set of images taken from different orientations. In this paper, we implement a light-field camera within a photogrammetry system in order to capture additional depth information, as well as the photogrammetric point cloud. Compared to a traditional camera that only captures the intensity of the incident light, a light-field camera also provides angular information for each pixel. In principle, this additional information allows 2D images to be reconstructed at a given focal plane, and hence a depth map can be computed. Through the fusion of light-field and photogrammetric data, we show that it is possible to improve the measurement uncertainty of a millimetre scale 3D object, compared to that from the individual systems. By imaging a series of test artefacts from various positions, individual point clouds were produced from depth-map information and triangulation of corresponding features between images. Using both measurements, data fusion methods were implemented in order to provide a single point cloud with reduced measurement uncertainty.

  20. [Quality of the structured abstracts presented at a congress].

    PubMed

    dos Santos, Edilson F; Pereira, Maurício G

    2007-01-01

    To assess and compare quality of abstracts presented at a medical congress (XIV Congresso da Sociedade Brasileira de Infectologia, November, 2005). The hypothesis is that material of better quality is chosen for oral presentation. All the 63 abstracts selected for oral presentation were compared with a random sample (n=63) of the 664 abstracts registered as poster presentations. Quality was measured by a structured questionnaire comprised of 33 criteria, distributed in eight categories: purpose, research design, setting, subjects, intervention, measurement, results and conclusions. The questionnaire was applied by one of the authors who were not blind to the objective of the study. The final score could range from 0 (bad) to 1 (excellent). Abstracts quality was considered moderately good. The overall mean quality scores were 0.60 and 0.62 respectively, for poster and oral presentation (p = 0.086). The criteria rated poorly were: subjects, variable measurements, location and conclusion. The tested hypothesis of better quality in abstracts selected for oral presentation has not been confirmed. It is recommended that organizers of the congresses the use of objective quality criteria to select the form of presentation while improving on quality.

  1. Out-of-equilibrium body potential measurements in pseudo-MOSFET for sensing applications

    NASA Astrophysics Data System (ADS)

    Benea, Licinius; Bawedin, Maryline; Delacour, Cécile; Ionica, Irina

    2018-05-01

    The aim of this paper is to present the out-of-equilibrium body potential behaviour in the Ψ-MOSFET configuration. Consistent measurements in this experimental setup succeeded in providing a substantial understanding of its characteristics in the depletion region. The final objective of this work is to envision this new measurement technique for biochemical sensor applications. Among its advantages, the most important are its simplicity, the good sensitivity, the measurement of a potential instead of a current and the low bias needed for detection compared to the conventional drain current measurements.

  2. Initial Parameters of Neutron Stars

    NASA Astrophysics Data System (ADS)

    Popov, S. B.; Turolla, R.

    2012-12-01

    A subpopulation of neutron stars (NSs), known as central compact objects (CCOs) in supernova remnants, are suspected to be low-field objects basing on P - ṗ measurements for three of them. The birth rate of low-field NSs is probably comparable with the birth rate of normal radio pulsars. However, among compact objects in High-Mass X-ray Binaries (HMXBs) we do not see robust candidates for low-field NSs. We propose that this contradiction can be solved if magnetic fields of CCOs was buried due to strong fall-back, and then the field emerges on the time scale 104 -105 yrs.

  3. Coherent diffraction imaging by moving a lens.

    PubMed

    Shen, Cheng; Tan, Jiubin; Wei, Ce; Liu, Zhengjun

    2016-07-25

    A moveable lens is used for determining amplitude and phase on the object plane. The extended fractional Fourier transform is introduced to address the single lens imaging. We put forward a fast algorithm for the transform by convolution. Combined with parallel iterative phase retrieval algorithm, it is applied to reconstruct the complex amplitude of the object. Compared with inline holography, the implementation of our method is simple and easy. Without the oversampling operation, the computational load is less. Also the proposed method has a superiority of accuracy over the direct focusing measurement for the imaging of small size objects.

  4. A coarse-to-fine kernel matching approach for mean-shift based visual tracking

    NASA Astrophysics Data System (ADS)

    Liangfu, L.; Zuren, F.; Weidong, C.; Ming, J.

    2009-03-01

    Mean shift is an efficient pattern match algorithm. It is widely used in visual tracking fields since it need not perform whole search in the image space. It employs gradient optimization method to reduce the time of feature matching and realize rapid object localization, and uses Bhattacharyya coefficient as the similarity measure between object template and candidate template. This thesis presents a mean shift algorithm based on coarse-to-fine search for the best kernel matching. This paper researches for object tracking with large motion area based on mean shift. To realize efficient tracking of such an object, we present a kernel matching method from coarseness to fine. If the motion areas of the object between two frames are very large and they are not overlapped in image space, then the traditional mean shift method can only obtain local optimal value by iterative computing in the old object window area, so the real tracking position cannot be obtained and the object tracking will be disabled. Our proposed algorithm can efficiently use a similarity measure function to realize the rough location of motion object, then use mean shift method to obtain the accurate local optimal value by iterative computing, which successfully realizes object tracking with large motion. Experimental results show its good performance in accuracy and speed when compared with background-weighted histogram algorithm in the literature.

  5. Evaluating structural pattern recognition for handwritten math via primitive label graphs

    NASA Astrophysics Data System (ADS)

    Zanibbi, Richard; Mouchère, Harold; Viard-Gaudin, Christian

    2013-01-01

    Currently, structural pattern recognizer evaluations compare graphs of detected structure to target structures (i.e. ground truth) using recognition rates, recall and precision for object segmentation, classification and relationships. In document recognition, these target objects (e.g. symbols) are frequently comprised of multiple primitives (e.g. connected components, or strokes for online handwritten data), but current metrics do not characterize errors at the primitive level, from which object-level structure is obtained. Primitive label graphs are directed graphs defined over primitives and primitive pairs. We define new metrics obtained by Hamming distances over label graphs, which allow classification, segmentation and parsing errors to be characterized separately, or using a single measure. Recall and precision for detected objects may also be computed directly from label graphs. We illustrate the new metrics by comparing a new primitive-level evaluation to the symbol-level evaluation performed for the CROHME 2012 handwritten math recognition competition. A Python-based set of utilities for evaluating, visualizing and translating label graphs is publicly available.

  6. Electric fish as natural models for technical sensor systems

    NASA Astrophysics Data System (ADS)

    von der Emde, Gerhard; Bousack, Herbert; Huck, Christina; Mayekar, Kavita; Pabst, Michael; Zhang, Yi

    2009-05-01

    Instead of vision, many animals use alternative senses for object detection. Weakly electric fish employ "active electrolocation", during which they discharge an electric organ emitting electrical current pulses (electric organ discharges, EOD). Local EODs are sensed by electroreceptors in the fish's skin, which respond to changes of the signal caused by nearby objects. Fish can gain information about attributes of an object, such as size, shape, distance, and complex impedance. When close to the fish, each object projects an 'electric image' onto the fish's skin. In order to get information about an object, the fish has to analyze the object's electric image by sampling its voltage distribution with the electroreceptors. We now know a great deal about the mechanisms the fish use to gain information about objects in their environment. Inspired by the remarkable capabilities of weakly electric fish in detecting and recognizing objects with their electric sense, we are designing technical sensor systems that can solve similar sensing problems. We applied the principles of active electrolocation to devices that produce electrical current pulses in water and simultaneously sense local current densities. Depending on the specific task, sensors can be designed which detect an object, localize it in space, determine its distance, and measure certain object properties such as material properties, thickness, or material faults. We present first experiments and FEM simulations on the optimal sensor arrangement regarding the sensor requirements e. g. localization of objects or distance measurements. Different methods of the sensor read-out and signal processing are compared.

  7. Extrapyramidal signs in normal pressure hydrocephalus: an objective assessment

    PubMed Central

    Mandir, Allen S; Hilfiker, Jennifer; Thomas, George; Minahan, Robert E; Crawford, Thomas O; Williams, Michael A; Rigamonti, Daniele

    2007-01-01

    Background Beyond the classic Normal Pressure Hydrocephalus (NPH) triad of gait disturbance, incontinence, and dementia are characteristic signs of motor dysfunction in NPH patients. We used highly sensitive and objective methods to characterize upper limb extrapyramidal signs in a series of NPH subjects compared with controls. Concentrated evaluation of these profound, yet underappreciated movement disorders of NPH before and after techniques of therapeutic intervention may lead to improved diagnosis, insight into pathophysiology, and targeted treatment. Methods Twenty-two (22) consecutive NPH patients and 17 controls performed an upper limb motor task battery where highly sensitive and objective measures of akinesia/bradykinesia, tone, and tremor were conducted. NPH subjects performed this test battery before and more than 36 h after continuous CSF drainage via a spinal catheter over 72 h and, in those subjects undergoing permanent ventriculo-peritoneal shunt placement, at least 12 weeks later. Control subjects performed the task battery at the same dates as the NPH subjects. Statistical analyses were applied to group populations of NPH and control subjects and repeated measures for within subject performance. Results Twenty (20) NPH subjects remained in the study following CSF drainage as did 14 controls. NPH subjects demonstrated akinesia/bradykinesia (prolonged reaction and movement times) and increased resting tone compared with controls. Furthermore, the NPH group demonstrated increased difficulty with self-initiated tasks compared with stimulus-initiated tasks. Following CSF drainage, some NPH subjects demonstrated reduced movement times with greater improvement in self- versus stimulus-initiated tasks. Group reaction time was unchanged. Resting tremor present in one NPH subject resolved following shunt placement. Tone measures were consistent for all subjects throughout the study. Conclusion Clinical motor signs of NPH subjects extend beyond gait deficits and include extrapyramidal manifestations of bradykinesia, akinesia, rigidity, and propensity to perform more poorly when external cues to move are absent. Objective improvement of some but not all of these features was seen following temporary or permanent CSF diversion. PMID:17697324

  8. Measurement of Flat Slab Deformations by the Multi-Image Photogrammetry Method

    NASA Astrophysics Data System (ADS)

    Marčiš, Marián; Fraštia, Marek; Augustín, Tomáš

    2017-12-01

    The use of photogrammetry during load tests of building components is a common practise all over the world. It is very effective thanks to its contactless approach, 3D measurement, fast data collection, and partial or full automation of image processing; it can deliver very accurate results. Multi-image convergent photogrammetry supported by artificial coded targets is the most accurate photogrammetric method when the targets are detected in an image with a higher degree of accuracy than a 0.1 pixel. It is possible to achieve an accuracy of 0.03 mm for all the points measured on the object observed if the camera is close enough to the object, and the positions of the camera and the number of shots are precisely planned. This contribution deals with the design of a special hanging frame for a DSLR camera used during the photogrammetric measurement of the deformation of flat concrete slab. The results of the photogrammetric measurements are compared to the results from traditional contact measurement techniques during load tests.

  9. Active Transportation to and on Campus is Associated With Objectively Measured Fitness Outcomes Among College Students.

    PubMed

    Bopp, Melissa; Bopp, Christopher; Schuchert, Megan

    2015-03-01

    Active transportation (AT) has been associated with positive health outcomes, yet limited research has addressed this with college students, a population at-risk for inactivity. The purpose of this study was to examine the relationship between AT behavior and objectively measured fitness outcomes. A volunteer, convenience sample (n = 299) of college students from a large northeastern university completed a survey about their AT habits to and on campus and psychosocial constructs related to AT and participated in a laboratory-based fitness assessment (cardiovascular endurance, muscular strength and endurance, flexibility, body composition).Off-campus students were dichotomized as nonactive (0-1 AT trips/day) or active travelers (> 1 AT trips/day) to campus; t-tests compared nonactive and active travelers for psychosocial and fitness variables. Students were 56.3% male, 79.2% non-Hispanic White, and primarily living off-campus (87%). Most students (n = 177, 59.2%) reported active travel between classes. Off-campus students were primarily active travelers (76.1%). Active travelers to campus had greater cardiovascular fitness (P = .005), were more flexible (P = .006) and had lower systolic blood pressure (P = .05) compared with nonactive travelers. This study documents a relationship between AT behavior and objectively measured fitness among college students and provides a rationale for targeting this behavior as a method for improving health outcomes.

  10. Cognitive-behavioral versus non-directive therapy for preschoolers with severe nighttime fears and sleep-related problems.

    PubMed

    Kahn, Michal; Ronen, Alon; Apter, Alan; Sadeh, Avi

    2017-04-01

    To compare the efficacy of a developmentally appropriate cognitive-behavioral therapy protocol for preschoolers with severe nighttime fears and sleep-related problems, with an active control treatment. Ninety children aged four to six years (63% boys) with severe nighttime fears and their parents were randomized to either cognitive-behavioral therapy including parent involved play (CBT-PIP) or to a structurally equivalent non-directive treatment (TEPT; triadic expressive play therapy). Treatment conditions were also equivalent in parent- and child-rated credibility and expectancy, and in therapist-rated compliance. Children and parents were assessed at baseline, during the first intervention week and four weeks after treatment. Measures included actigraphy, daily sleep logs, structured diagnostic interviews and parent questionnaires. Significant reductions were observed in nighttime fears and objectively and subjectively measured sleep disruptions in both intervention groups following treatment. Parent reports indicated more advantageous outcomes for CBT-PIP compared to TEPT, with greater reductions in sleep problems and co-sleeping as well as higher customer satisfaction in the former group. While CBT-PIP showed no significant advantage compared to the active control in reducing fears or in improving objectively measured sleep, it was significantly more beneficial in reducing the adverse behavioral features of nighttime fears. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Separating the effects of shelter from additional cage enhancements for group-housed BALB/cJ mice.

    PubMed

    Swetter, Brentt J; Karpiak, Christie P; Cannon, J Timothy

    2011-05-20

    Enrichment studies with rodents have demonstrated that cage enhancements can improve animal welfare and performance on common behavioral measures, but few studies have compared more than one type of enrichment or controlled for confounds, and some have revealed undesirable effects including increased aggression. We compared effects on male (n=51) and female (n=52) BALB/cJ mice of three common additions to a standard home cage: shelter, shelter+running wheel, and shelter+novel objects. Mice in all conditions lived in standard sized cages with 3-4 mice per cage. Males evidenced significant condition effects. Shelter increased longevity and maintained low levels of aggression. Adding a running wheel increased aggression over shelter alone, changed behavior in the elevated plus (EP) and open field (OF), and maintained the improved longevity seen in all shelter conditions. Novel objects impacted behavioral measures compared to the standard condition. An Igloo shelter without running wheel creates a very different home cage environment than the same shelter with the running wheel attached. Shelter, with positive impact on animal welfare, minimal effects on some common behavioral measures, and some positive effects on test variance, warrants consideration for routine inclusion with group-housed BALB/cJ males. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Drag measurements on a laminar flow body of revolution in Langley's 13 inch magnetic suspension and balance system. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Dress, David A.

    1988-01-01

    Low-speed wind tunnel drag force measurements were taken on a laminar flow body of revolution free of support interference. This body was tested at zero incidence in the NASA Langley 13 inch Magnetic Suspension and Balance System (MSBS). The primary objective of these tests was to substantiate the drag force measuring capabilities of the 13 inch MSBS. A secondary objective was to obtain support interference free drag measurements on an axisymmetric body of interest. Both objectives were met. The drag force calibrations and wind-on repeatability data provide a means of assessing the drag force measuring capabilities of the 13 inch MSBS. The measured drag coefficients for this body are of interest to researchers actively involved in designing minimum drag fuselage shapes. Additional investigations included: the effects of fixing transition; the effects of fins installed in the tail; surface flow visualizations using both liquid crystals and oil flow; and base pressure measurements using a one-channel telemetry system. Two drag prediction codes were used to assess their usefulness in estimating overall body drag. These theoretical results did not compare well with the measured values because of the following: incorrect or non-existent modeling of a laminar separation bubble on the body and incorrect of non-existent estimates of base pressure drag.

  13. Comparing visual and objective skin assessment with pressure injury risk.

    PubMed

    Borzdynski, Caroline J; McGuiness, William; Miller, Charne

    2016-08-01

    Contemporary approaches to pressure injury (PI) risk identification rely on the use of risk assessment tools and visual skin assessment. Objective biophysical measures that assess skin hydration, melanin, erythema and lipids have not been traditionally used in PI risk; however, these may prove useful as a risk assessment tool. The relationship between subjective visual assessments of skin condition, biophysical measures and PI risk warrants investigation. This study used a descriptive correlational design to examine the relationship between measures of skin hydration, colour (melanin and erythema) and lipids at PI-prone areas amongst geriatric persons (n = 38), obtained using biophysical skin measures and visual skin assessment. Twice daily measures of epidermal hydration, colour and lipids were assessed using the SD202 Skin Diagnostic (Courage + Khazaka GmBH, Cologne, Germany) over pressure-prone areas of the body of study participants over seven consecutive days. Concurrent visual assessment of skin hydration and colour was performed. Results obtained using the SD202 Skin Diagnostic were compared with results gathered from visual assessment and examined for their association with participants' PI risk based on scores of the Norton Risk Assessment Scale. While epidermal hydration and skin colour reading scores did not vary significantly over the data collection period, lipid readings could not be registered on any occasion. With the exception of skin dryness, skin parameters via both objective and subjective means had significant, positive correlations. Statistically significant correlations emerged between visual assessment of skin wetness at the sacrum (r = -0·441, P < 0·01) and ischia (r = -0·468, P < 0·01) and Norton Risk Assessment Scale scores. It was found that the objective assessment of epidermal hydration (skin wetness) was also significantly associated with PI risk at the sacrum (r = -0·528, P < 0·01), as well as the right ischia (r = -0·410, P < 0·05) and left ischia (r = -0·407, P < 0·05). Erythema, when assessed objectively, was significantly correlated with PI risk at the sacrum (r = -0·322, P < 0·05). Such findings indicating that the finer measures afforded by the SD202 Skin Diagnostic in the assessment of the subtle red hues displayed in erythematous skin may provide an additional advantage over traditional, clinician assessment. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  14. Evaluation of low-cost, objective instruments for assessing physical activity in 10-11-year-old children.

    PubMed

    Hart, Teresa L; Brusseau, Timothy; Kulinna, Pamela Hodges; McClain, James J; Tudor-Locke, Catrine

    2011-12-01

    This study compared step counts detected by four, low-cost, objective, physical-activity-assessment instruments and evaluated their ability to detect moderate-to-vigorous physical activity (MVPA) compared to the ActiGraph accelerometer (AG). Thirty-six 10-11-year-old children wore the NL-1000, Yamax Digiwalker SW 200, Omron HJ-151, and Walk4Life MVP concurrently with the AG during school hours on a single day. AG MVPA was derived from activity count data using previously validated cut points. Two of the evaluated instruments provided similar group mean MVPA and step counts compared to AG (dependent on cut point). Low-cost instruments may be useful for measurement of both MVPA and steps in children's physical activity interventions and program evaluation.

  15. Real three-dimensional objects: effects on mental rotation.

    PubMed

    Felix, Michael C; Parker, Joshua D; Lee, Charles; Gabriel, Kara I

    2011-08-01

    The current experiment investigated real three-dimensional (3D) objects with regard to performance on a mental rotation task and whether the appearance of sex differences may be mediated by experiences with spatially related activities. 40 men and 40 women were presented with alternating timed trials consisting of real-3D objects or two-dimensional illustrations of 3D objects. Sex differences in spatially related activities did not significantly influence the finding that men outperformed women on mental rotation of either stimulus type. However, on measures related to spatial activities, self-reported proficiency using maps correlated positively with performance only on trials with illustrations whereas self-reported proficiency using GPS correlated negatively with performance regardless of stimulus dimensionality. Findings may be interpreted as suggesting that rotating real-3D objects utilizes distinct but overlapping spatial skills compared to rotating two-dimensional representations of 3D objects, and real-3D objects can enhance mental rotation performance.

  16. Graphical representation of robot grasping quality measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varma, V.; Tasch, U.

    1993-11-01

    When an object is held by a multi-fingered hand, the values of the contact forces can be multivalued. An objective function, when used in conjunction with the frictional and geometric constraints of the grasp, can however, give a unique set of finger force values. The selection of the objective function in determining the finger forces is dependent on the type of grasp required, the material properties of the object, and the limitations of the robot fingers. In this paper several optimization functions are studied and their merits highlighted. A graphical representation of the finger force values and the objective functionmore » is introduced that enable one in selecting and comparing various grasping configurations. The impending motion of the object at different torque and finger force values are determined by observing the normalized coefficient of friction plots.« less

  17. Dimensional analyses of frontal posed smile attractiveness in Japanese female patients.

    PubMed

    Hata, Kyoko; Arai, Kazuhito

    2016-01-01

    To identify appropriate dimensional items in objective diagnostic analysis for attractiveness of frontal posed smile in Japanese female patients by comparing with the result of human judgments. Photographs of frontal posed smiles of 100 Japanese females after orthodontic treatment were evaluated by 20 dental students (10 males and 10 females) using a visual analogue scale (VAS). The photographs were ranked based on the VAS evaluations and the 25 photographs with the highest evaluations were selected as group A, and the 25 photos with the lowest evaluations were designated group B. Then 12 dimensional items of objective analysis selected from a literature review were measured. Means and standard deviations for measurements of the dimensional items were compared between the groups using the unpaired t-test with a significance level of P < .05. Mean values were significantly smaller in group A than in group B for interlabial gap, intervermilion distance, maxillary gingival display, maximum incisor exposure, and lower lip to incisor (P < .05). Significant differences were observed only in the vertical dimension, not in the transverse dimension. Five of the 12 objective diagnostic items were correlated with human judgments of the attractiveness of frontal posed smile in Japanese females after orthodontic treatment.

  18. Evaluation of the geometric stability and the accuracy potential of digital cameras — Comparing mechanical stabilisation versus parameterisation

    NASA Astrophysics Data System (ADS)

    Rieke-Zapp, D.; Tecklenburg, W.; Peipe, J.; Hastedt, H.; Haig, Claudia

    Recent tests on the geometric stability of several digital cameras that were not designed for photogrammetric applications have shown that the accomplished accuracies in object space are either limited or that the accuracy potential is not exploited to the fullest extent. A total of 72 calibrations were calculated with four different software products for eleven digital camera models with different hardware setups, some with mechanical fixation of one or more parts. The calibration procedure was chosen in accord to a German guideline for evaluation of optical 3D measuring systems [VDI/VDE, VDI/VDE 2634 Part 1, 2002. Optical 3D Measuring Systems-Imaging Systems with Point-by-point Probing. Beuth Verlag, Berlin]. All images were taken with ringflashes which was considered a standard method for close-range photogrammetry. In cases where the flash was mounted to the lens, the force exerted on the lens tube and the camera mount greatly reduced the accomplished accuracy. Mounting the ringflash to the camera instead resulted in a large improvement of accuracy in object space. For standard calibration best accuracies in object space were accomplished with a Canon EOS 5D and a 35 mm Canon lens where the focusing tube was fixed with epoxy (47 μm maximum absolute length measurement error in object space). The fixation of the Canon lens was fairly easy and inexpensive resulting in a sevenfold increase in accuracy compared with the same lens type without modification. A similar accuracy was accomplished with a Nikon D3 when mounting the ringflash to the camera instead of the lens (52 μm maximum absolute length measurement error in object space). Parameterisation of geometric instabilities by introduction of an image variant interior orientation in the calibration process improved results for most cameras. In this case, a modified Alpa 12 WA yielded the best results (29 μm maximum absolute length measurement error in object space). Extending the parameter model with FiBun software to model not only an image variant interior orientation, but also deformations in the sensor domain of the cameras, showed significant improvements only for a small group of cameras. The Nikon D3 camera yielded the best overall accuracy (25 μm maximum absolute length measurement error in object space) with this calibration procedure indicating at the same time the presence of image invariant error in the sensor domain. Overall, calibration results showed that digital cameras can be applied for an accurate photogrammetric survey and that only a little effort was sufficient to greatly improve the accuracy potential of digital cameras.

  19. Segmentation quality evaluation using region-based precision and recall measures for remote sensing images

    NASA Astrophysics Data System (ADS)

    Zhang, Xueliang; Feng, Xuezhi; Xiao, Pengfeng; He, Guangjun; Zhu, Liujun

    2015-04-01

    Segmentation of remote sensing images is a critical step in geographic object-based image analysis. Evaluating the performance of segmentation algorithms is essential to identify effective segmentation methods and optimize their parameters. In this study, we propose region-based precision and recall measures and use them to compare two image partitions for the purpose of evaluating segmentation quality. The two measures are calculated based on region overlapping and presented as a point or a curve in a precision-recall space, which can indicate segmentation quality in both geometric and arithmetic respects. Furthermore, the precision and recall measures are combined by using four different methods. We examine and compare the effectiveness of the combined indicators through geometric illustration, in an effort to reveal segmentation quality clearly and capture the trade-off between the two measures. In the experiments, we adopted the multiresolution segmentation (MRS) method for evaluation. The proposed measures are compared with four existing discrepancy measures to further confirm their capabilities. Finally, we suggest using a combination of the region-based precision-recall curve and the F-measure for supervised segmentation evaluation.

  20. Distance measurement based on light field geometry and ray tracing.

    PubMed

    Chen, Yanqin; Jin, Xin; Dai, Qionghai

    2017-01-09

    In this paper, we propose a geometric optical model to measure the distances of object planes in a light field image. The proposed geometric optical model is composed of two sub-models based on ray tracing: object space model and image space model. The two theoretic sub-models are derived on account of on-axis point light sources. In object space model, light rays propagate into the main lens and refract inside it following the refraction theorem. In image space model, light rays exit from emission positions on the main lens and subsequently impinge on the image sensor with different imaging diameters. The relationships between imaging diameters of objects and their corresponding emission positions on the main lens are investigated through utilizing refocusing and similar triangle principle. By combining the two sub-models together and tracing light rays back to the object space, the relationships between objects' imaging diameters and corresponding distances of object planes are figured out. The performance of the proposed geometric optical model is compared with existing approaches using different configurations of hand-held plenoptic 1.0 cameras and real experiments are conducted using a preliminary imaging system. Results demonstrate that the proposed model can outperform existing approaches in terms of accuracy and exhibits good performance at general imaging range.

  1. Effects of a Web-Based Personalized Intervention on Physical Activity in European Adults: A Randomized Controlled Trial.

    PubMed

    Marsaux, Cyril Fm; Celis-Morales, Carlos; Fallaize, Rosalind; Macready, Anna L; Kolossa, Silvia; Woolhead, Clara; O'Donovan, Clare B; Forster, Hannah; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Lambrinou, Christina-Paulina; Moschonis, George; Surwillo, Agnieszka; Godlewska, Magdalena; Goris, Annelies; Hoonhout, Jettie; Drevon, Christian A; Manios, Yannis; Traczyk, Iwona; Walsh, Marianne C; Gibney, Eileen R; Brennan, Lorraine; Martinez, J Alfredo; Lovegrove, Julie A; Gibney, Michael J; Daniel, Hannelore; Mathers, John C; Saris, Wim Hm

    2015-10-14

    The high prevalence of physical inactivity worldwide calls for innovative and more effective ways to promote physical activity (PA). There are limited objective data on the effectiveness of Web-based personalized feedback on increasing PA in adults. It is hypothesized that providing personalized advice based on PA measured objectively alongside diet, phenotype, or genotype information would lead to larger and more sustained changes in PA, compared with nonpersonalized advice. A total of 1607 adults in seven European countries were randomized to either a control group (nonpersonalized advice, Level 0, L0) or to one of three personalized groups receiving personalized advice via the Internet based on current PA plus diet (Level 1, L1), PA plus diet and phenotype (Level 2, L2), or PA plus diet, phenotype, and genotype (Level 3, L3). PA was measured for 6 months using triaxial accelerometers, and self-reported using the Baecke questionnaire. Outcomes were objective and self-reported PA after 3 and 6 months. While 1270 participants (85.81% of 1480 actual starters) completed the 6-month trial, 1233 (83.31%) self-reported PA at both baseline and month 6, but only 730 (49.32%) had sufficient objective PA data at both time points. For the total cohort after 6 months, a greater improvement in self-reported total PA (P=.02) and PA during leisure (nonsport) (P=.03) was observed in personalized groups compared with the control group. For individuals advised to increase PA, we also observed greater improvements in those two self-reported indices (P=.006 and P=.008, respectively) with increased personalization of the advice (L2 and L3 vs L1). However, there were no significant differences in accelerometer results between personalized and control groups, and no significant effect of adding phenotypic or genotypic information to the tailored feedback at month 3 or 6. After 6 months, there were small but significant improvements in the objectively measured physical activity level (P<.05), moderate PA (P<.01), and sedentary time (P<.001) for individuals advised to increase PA, but these changes were similar across all groups. Different levels of personalization produced similar small changes in objective PA. We found no evidence that personalized advice is more effective than conventional "one size fits all" guidelines to promote changes in PA in our Web-based intervention when PA was measured objectively. Based on self-reports, PA increased to a greater extent with more personalized advice. Thus, it is crucial to measure PA objectively in any PA intervention study. ClinicalTrials.gov NCT01530139; http://clinicaltrials.gov/show/NCT01530139 (Archived by WebCite at: http://www.webcitation.org/6XII1QwHz).

  2. Kinesthetic deficits after perinatal stroke: robotic measurement in hemiparetic children.

    PubMed

    Kuczynski, Andrea M; Semrau, Jennifer A; Kirton, Adam; Dukelow, Sean P

    2017-02-15

    While sensory dysfunction is common in children with hemiparetic cerebral palsy (CP) secondary to perinatal stroke, it is an understudied contributor to disability with limited objective measurement tools. Robotic technology offers the potential to objectively measure complex sensorimotor function but has been understudied in perinatal stroke. The present study aimed to quantify kinesthetic deficits in hemiparetic children with perinatal stroke and determine their association with clinical function. Case-control study. Participants were 6-19 years of age. Stroke participants had MRI confirmed unilateral perinatal arterial ischemic stroke or periventricular venous infarction, and symptomatic hemiparetic cerebral palsy. Participants completed a robotic assessment of upper extremity kinesthesia using a robotic exoskeleton (KINARM). Four kinesthetic parameters (response latency, initial direction error, peak speed ratio, and path length ratio) and their variabilities were measured with and without vision. Robotic outcomes were compared across stroke groups and controls and to clinical measures of sensorimotor function. Forty-three stroke participants (23 arterial, 20 venous, median age 12 years, 42% female) were compared to 106 healthy controls. Stroke cases displayed significantly impaired kinesthesia that remained when vision was restored. Kinesthesia was more impaired in arterial versus venous lesions and correlated with clinical measures. Robotic assessment of kinesthesia is feasible in children with perinatal stroke. Kinesthetic impairment is common and associated with stroke type. Failure to correct with vision suggests sensory network dysfunction.

  3. A comparison of participation outcome measures and the International Classification of Functioning, Disability and Health Core Sets for traumatic brain injury.

    PubMed

    Chung, Pearl; Yun, Sarah Jin; Khan, Fary

    2014-02-01

    To compare the contents of participation outcome measures in traumatic brain injury with the International Classification of Functioning, Disability and Health (ICF) Core Sets for traumatic brain injury. A systematic search with an independent review process selected relevant articles to identify outcome measures in participation in traumatic brain injury. Instruments used in two or more studies were linked to the ICF categories, which identified categories in participation for comparison with the ICF Core Sets for traumatic brain injury. Selected articles (n = 101) identified participation instruments used in two or more studies (n = 9): Community Integration Questionnaire, Craig Handicap Assessment and Reporting Technique, Mayo-Portland Adaptability Inventory-4 Participation Index, Sydney Psychosocial Reintegration Scale Version-2, Participation Assessment with Recombined Tool-Objective, Community Integration Measure, Participation Objective Participation Subjective, Community Integration Questionnaire-2, and Quality of Community Integration Questionnaire. Each instrument was linked to 4-35 unique second-level ICF categories, of which 39-100% related to participation. Instruments addressed 86-100% and 50-100% of the participation categories in the Comprehensive and Brief ICF Core Sets for traumatic brain injury, respectively. Participation measures in traumatic brain injury were compared with the ICF Core Sets for traumatic brain injury. The ICF Core Sets for traumatic brain injury could contribute to the development and selection of participation measures.

  4. Are Self-report Measures Able to Define Individuals as Physically Active or Inactive?

    PubMed

    Steene-Johannessen, Jostein; Anderssen, Sigmund A; van der Ploeg, Hidde P; Hendriksen, Ingrid J M; Donnelly, Alan E; Brage, Søren; Ekelund, Ulf

    2016-02-01

    Assess the agreement between commonly used self-report methods compared with objectively measured physical activity (PA) in defining the prevalence of individuals compliant with PA recommendations. Time spent in moderate and vigorous PA (MVPA) was measured at two time points in 1713 healthy individuals from nine European countries using individually calibrated combined heart rate and movement sensing. Participants also completed the Recent Physical Activity Questionnaire (RPAQ), short form of the International Physical Activity Questionnaire (IPAQ), and short European Prospective Investigation into Cancer and Nutrition Physical Activity Questionnaire (EPIC-PAQ). Individuals were categorized as active (e.g., reporting ≥150 min of MVPA per week) or inactive, based on the information derived from the different measures. Sensitivity and specificity analyses and Kappa statistics were performed to evaluate the ability of the three PA questionnaires to correctly categorize individuals as active or inactive. Prevalence estimates of being sufficiently active varied significantly (P for all <0.001) between self-report measures (IPAQ 84.2% [95% confidence interval {CI}, 82.5-85.9], RPAQ 87.6% [95% CI, 85.9-89.1], EPIC-PAQ 39.9% [95% CI, 37.5-42.1] and objective measure 48.5% [95% CI, 41.6-50.9]. All self-report methods showed low or moderate sensitivity (IPAQ 20.0%, RPAQ 18.7%, and EPIC-PAQ 69.8%) to correctly classify inactive people and the agreement between objective and self-reported PA was low (ĸ = 0.07 [95% CI, 0.02-0.12], 0.12 [95% CI, 0.06-0.18], and 0.19 [95% CI, 0.13-0.24] for IPAQ, RPAQ, and EPIC-PAQ, respectively). The modest agreement between self-reported and objectively measured PA suggests that population levels of PA derived from self-report should be interpreted cautiously. Implementation of objective measures in large-scale cohort studies and surveillance systems is recommended.

  5. Comparison of RCS prediction techniques, computations and measurements

    NASA Astrophysics Data System (ADS)

    Brand, M. G. E.; Vanewijk, L. J.; Klinker, F.; Schippers, H.

    1992-07-01

    Three calculation methods to predict radar cross sections (RCS) of three dimensional objects are evaluated by computing the radar cross sections of a generic wing inlet configuration. The following methods are applied: a three dimensional high frequency method, a three dimensional boundary element method, and a two dimensional finite difference time domain method. The results of the computations are compared with the data of measurements.

  6. A SOFTWARE TOOL TO COMPARE MEASURED AND SIMULATED BUILDING ENERGY PERFORMANCE DATA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maile, Tobias; Bazjanac, Vladimir; O'Donnell, James

    2011-11-01

    Building energy performance is often inadequate when compared to design goals. To link design goals to actual operation one can compare measured with simulated energy performance data. Our previously developed comparison approach is the Energy Performance Comparison Methodology (EPCM), which enables the identification of performance problems based on a comparison of measured and simulated performance data. In context of this method, we developed a software tool that provides graphing and data processing capabilities of the two performance data sets. The software tool called SEE IT (Stanford Energy Efficiency Information Tool) eliminates the need for manual generation of data plots andmore » data reformatting. SEE IT makes the generation of time series, scatter and carpet plots independent of the source of data (measured or simulated) and provides a valuable tool for comparing measurements with simulation results. SEE IT also allows assigning data points on a predefined building object hierarchy and supports different versions of simulated performance data. This paper briefly introduces the EPCM, describes the SEE IT tool and illustrates its use in the context of a building case study.« less

  7. What is in a name? Comparing diagnostic criteria for chronic fatigue syndrome with or without fibromyalgia.

    PubMed

    Meeus, Mira; Ickmans, Kelly; Struyf, Filip; Kos, Daphne; Lambrecht, Luc; Willekens, Barbara; Cras, Patrick; Nijs, Jo

    2016-01-01

    The current study had two objectives. (1) to compare objective and self-report measures in patients with chronic fatigue syndrome (CFS) according to the 1994 Center for Disease Control (CDC) criteria, patients with multiple sclerosis (MS), and healthy controls, and (2) to contrast CFS patients who only fulfill CDC criteria to those who also fulfill the criteria for myalgic encephalomyelitis (ME), the 2003 Canadian criteria for ME/CFS, or the comorbid diagnosis of fibromyalgia (FM). One hundred six participants (48 CFS patients diagnosed following the 1994 CDC criteria, 19 MS patients, and 39 healthy controls) completed questionnaires assessing symptom severity, quality of life, daily functioning, and psychological factors. Objective measures consisted of activity monitoring, evaluation of maximal voluntary contraction and muscle recovery, and cognitive performance. CFS patients were screened whether they also fulfilled ME criteria, the Canadian criteria, and the diagnosis of FM. CFS patients scored higher on symptom severity, lower on quality of life, and higher on depression and kinesiophobia and worse on MVC, muscle recovery, and cognitive performance compared to the MS patients and the healthy subjects. Daily activity levels were also lower compared to healthy subjects. Only one difference was found between those fulfilling the ME criteria and those who did not regarding the degree of kinesiophobia (lower in ME), while comorbidity for FM significantly increased the symptom burden. CFS patients report more severe symptoms and are more disabled compared to MS patients and healthy controls. Based on the present study, fulfillment of the ME or Canadian criteria did not seem to give a clinically different picture, whereas a diagnosis of comorbid FM selected symptomatically worse and more disabled patients.

  8. Accuracy and reliability testing of two methods to measure internal rotation of the glenohumeral joint.

    PubMed

    Hall, Justin M; Azar, Frederick M; Miller, Robert H; Smith, Richard; Throckmorton, Thomas W

    2014-09-01

    We compared accuracy and reliability of a traditional method of measurement (most cephalad vertebral spinous process that can be reached by a patient with the extended thumb) to estimates made with the shoulder in abduction to determine if there were differences between the two methods. Six physicians with fellowship training in sports medicine or shoulder surgery estimated measurements in 48 healthy volunteers. Three were randomly chosen to make estimates of both internal rotation measurements for each volunteer. An independent observer made objective measurements on lateral scoliosis films (spinous process method) or with a goniometer (abduction method). Examiners were blinded to objective measurements as well as to previous estimates. Intraclass coefficients for interobserver reliability for the traditional method averaged 0.75, indicating good agreement among observers. The difference in vertebral level estimated by the examiner and the actual radiographic level averaged 1.8 levels. The intraclass coefficient for interobserver reliability for the abduction method averaged 0.81 for all examiners, indicating near-perfect agreement. Confidence intervals indicated that estimates were an average of 8° different from the objective goniometer measurements. Pearson correlation coefficients of intraobserver reliability for the abduction method averaged 0.94, indicating near-perfect agreement within observers. Confidence intervals demonstrated repeated estimates between 5° and 10° of the original. Internal rotation estimates made with the shoulder abducted demonstrated interobserver reliability superior to that of spinous process estimates, and reproducibility was high. On the basis of this finding, we now take glenohumeral internal rotation measurements with the shoulder in abduction and use a goniometer to maximize accuracy and objectivity. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  9. Diurnal rhythm and concordance between objective and subjective hot flashes: the Hilo Women's Health Study.

    PubMed

    Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E

    2010-01-01

    The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.

  10. Moire technique utilization for detection and measurement of scoliosis

    NASA Astrophysics Data System (ADS)

    Zawieska, Dorota; Podlasiak, Piotr

    1993-02-01

    Moire projection method enables non-contact measurement of the shape or deformation of different surfaces and constructions by fringe pattern analysis. The fringe map acquisition of the whole surface of the object under test is one of the main advantages compared with 'point by point' methods. The computer analyzes the shape of the whole surface and next user can selected different points or cross section of the object map. In this paper a few typical examples of an application of the moire technique in solving different medical problems will be presented. We will also present to you the equipment the moire pattern analysis is done in real time using the phase stepping method with CCD camera.

  11. Observations of emission in bright, low redshift quasars

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Ultraviolet, infrared, and optical spectra were combined to obtain a data set sample as broad as possible in the range of hydrogen lines in individual quasars. From the measured Lyman fluxes, coupled with Balmer and Paschen line fluxes measured in these same objects, an effort was made to establish observational constraints that would guide models of the broad emission line regions of quasars. It was found that IUE spectra were generally of sufficiently high quality to derive line profiles of the ultraviolet lines Lyman alpha and CIV 1550 A, which were compared to the Balmer line profiles. The objects observed and the line fluxes are tabulated. Plots of line profiles are included.

  12. An analysis of labor and multifactor productivity in air transportation : 1990 - 2001

    DOT National Transportation Integrated Search

    2002-01-01

    The analysis has two main objectives: 1) to examine : labor productivity and multifactor productivity : (MFP) in U.S. air transportation during the 1990 : to 2001 period and to compare these measures to : those of two other transportation subsectors ...

  13. Aircraft Engine On-Line Diagnostics Through Dual-Channel Sensor Measurements: Development of an Enhanced System

    NASA Technical Reports Server (NTRS)

    Kobayashi, Takahisa; Simon, Donald L.

    2008-01-01

    In this paper, an enhanced on-line diagnostic system which utilizes dual-channel sensor measurements is developed for the aircraft engine application. The enhanced system is composed of a nonlinear on-board engine model (NOBEM), the hybrid Kalman filter (HKF) algorithm, and fault detection and isolation (FDI) logic. The NOBEM provides the analytical third channel against which the dual-channel measurements are compared. The NOBEM is further utilized as part of the HKF algorithm which estimates measured engine parameters. Engine parameters obtained from the dual-channel measurements, the NOBEM, and the HKF are compared against each other. When the discrepancy among the signals exceeds a tolerance level, the FDI logic determines the cause of discrepancy. Through this approach, the enhanced system achieves the following objectives: 1) anomaly detection, 2) component fault detection, and 3) sensor fault detection and isolation. The performance of the enhanced system is evaluated in a simulation environment using faults in sensors and components, and it is compared to an existing baseline system.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paschoal, Cinthia M. M.; Ferreira, Fernanda Carla L.; Santos, Luiz A. P.

    The advance of multislice computed tomography (CT) has become inadequate the currently dosimetric protocol used in CT. Instead of dosimetry based on the measurement of CTDI using a pencil ion chamber of 100 m of length, it was proposed the use of a small ion chamber (IC) and the calculating the dose equilibrium (Deq) at the location of the chamber. The objective of this work was to compare the performance of a short IC and a commercial photodiode to measure the accumulated dose at the center of the scan length L, DL(0), and to obtain the equilibrium dose Deq usingmore » the two detectors. The result for L=100 mm was compared with the result of a pencil chamber. The results indicate that the commercial photodiode is suitable to measure the accumulated dose at the center of the scan length L as compared with the ion chambers. This methodology allows measurements of the accumulated dose for any desired scan length, allowing measuring the equilibrium dose Deq if the phantom is long enough to allow it. (authors)« less

  15. [Comparative study of cone-beam CT and spiral CT in measuring the length of styloid process].

    PubMed

    Song, Y S; Liu, L F

    2018-06-19

    Objective: To compare the difference of measuring the length of styloid process between spiral CT with high resolution and cone-beam CT(CBCT). Methods: Five specimens (including 5 pairs of styloid processes) were selected randomly from the Anatomy Laboratory of Otolaryngology Department, all the specimens underwent spiral CT with high resolution and cone-beam CT retrospectively.With the original DICOM data, the styloid processes were shown in one plate by multiple plate reconstruction technique, and later the length of styloid processes of each specimen were measured separately by software NNT Viewer (to CBCT) or Osrix (to spiral CT with high resolution). Results: The length of styloid processes measured by CBCT and spiral CT was (26.8±5.5) mm and (27.1±5.4) mm respectively, and there was no statistical difference between the two groups. Conclusion: In respect of measuring the length of styloid process, the CBCT has the same value in clinical practice comparing to spiral CT with high resolution.

  16. Objective and subjective treatment evaluation of scars using optical coherence tomography, sonography, photography, and standardised questionnaires.

    PubMed

    Reinholz, Markus; Schwaiger, Hannah; Poetschke, Julian; Epple, Andreas; Ruzicka, Thomas; Von Braunmühl, Tanja; Gauglitz, Gerd G

    2016-12-01

    Currently, different types of treatments for pathological scars are available, however, to date, there is no established method of measurement to objectively assess therapeutic outcome. Treatment success is usually evaluated clinically by the physician and patient. Non-invasive imaging techniques, such as HD-OCT (high-definition optical coherence tomography), may represent a valuable diagnostic tool to objectively measure therapeutic outcome. To compare HD-OCT with ultrasound and subjective evaluation tools, such as questionnaires. In total, eight patients with pathological scars were treated in this pilot study with cryotherapy and intralesional steroid injections, and evaluated pre- and post-treatment using clinical examination, photography, sonography, and HD-OCT. The analysis of objective and subjective measuring methods was used to draw direct comparisons. HD-OCT revealed reduced epidermal and dermal thickness of the scar after four treatments with triamcinolone acetonide and cryotherapy. Based on sonography, a total reduction in scar height and reduction in scar depth was demonstrated. Both methods correlated well with the injected amount of triamcinolone acetonide. In addition, a positive correlation between well-established subjective and objective evaluation methods was found. We demonstrate that HD-OCT may be used as an objective diagnostic instrument to evaluate skin thickness under therapy for pathological scars, and serves as a valuable adjunctive device in combination with ultrasound and subjective evaluation tools. This provides additional information for the therapist concerning the quality and success of the applied treatment.

  17. A fast neural signature of motivated attention to consumer goods separates the sexes.

    PubMed

    Junghöfer, Markus; Kissler, Johanna; Schupp, Harald T; Putsche, Christian; Elling, Ludger; Dobel, Christian

    2010-01-01

    Emotional stimuli guide selective visual attention and receive enhanced processing. Previous event-related potential studies have identified an early (>120 ms) negative potential shift over occipito-temporal regions (early posterior negativity, EPN) presumed to indicate the facilitated processing of survival-relevant stimuli. The present study investigated whether this neural signature of motivated attention is also responsive to the intrinsic significance of man-made objects and consumer goods. To address this issue, we capitalized on gender differences towards specific man-made objects, shoes and motorcycles, for which the Statistical Yearbook 2005 of Germany's Federal Statistical Office (Statistisches Bundesamt, 2005) revealed pronounced differences in consumer behavior. In a passive viewing paradigm, male and female participants viewed pictures of motorcycles and shoes, while their magnetoencephalographic brain responses were measured. Source localization of the magnetic counterpart of the EPN (EPNm) revealed pronounced gender differences in picture processing. Specifically, between 130 and 180 ms, all female participants generated stronger activity in occipito-temporal regions when viewing shoes compared to motorcycles, while all men except one showed stronger activation for motorcycles than shoes. Thus, the EPNm allowed a sex-dimorphic classification of the processing of consumer goods. Self-report data confirmed gender differences in consumer behavior, which, however, were less distinct compared to the brain based measure. Considering the latency of the EPNm, the reflected automatic emotional network activity is most likely not yet affected by higher cognitive functions such as response strategies or social expectancy. Non-invasive functional neuroimaging measures of early brain activity may thus serve as objective measure for individual preferences towards consumer goods.

  18. The moderating role of objective and subjective numeracy in attribute framing.

    PubMed

    Gamliel, Eyal; Kreiner, Hamutal; Garcia-Retamero, Rocio

    2016-04-01

    Previous research has found that objective numeracy moderates framing effects: People who are less numerate were found to be more susceptible to goal-framing and attribute-framing effects than people who are highly numerate. This study examined the possibility that subjective numeracy likewise moderates attribute framing in contexts where participants are presented with percentages of success or failure. The results show that compared with highly numerate participants, less numerate participants were more susceptible to the effect of attribute framing. Interestingly, this moderating effect was revealed only when using objective numeracy measures, and not when subjective numeracy measures were used. Future research is suggested to replicate these findings, to establish the generalizability of numeracy as a moderator of other cognitive biases, and to examine several possible theoretical explanations for the differential moderation of attribute-framing bias. © 2015 International Union of Psychological Science.

  19. Calibrating excitation light fluxes for quantitative light microscopy in cell biology

    PubMed Central

    Grünwald, David; Shenoy, Shailesh M; Burke, Sean; Singer, Robert H

    2011-01-01

    Power output of light bulbs changes over time and the total energy delivered will depend on the optical beam path of the microscope, filter sets and objectives used, thus making comparison between experiments performed on different microscopes complicated. Using a thermocoupled power meter, it is possible to measure the exact amount of light applied to a specimen in fluorescence microscopy, regardless of the light source, as the light power measured can be translated into a power density at the sample. This widely used and simple tool forms the basis of a new degree of calibration precision and comparability of results among experiments and setups. Here we describe an easy-to-follow protocol that allows researchers to precisely estimate excitation intensities in the object plane, using commercially available opto-mechanical components. The total duration of this protocol for one objective and six filter cubes is 75 min including start-up time for the lamp. PMID:18974739

  20. Physical Function Does Not Predict Care Assessment Need Score in Older Veterans.

    PubMed

    Serra, Monica C; Addison, Odessa; Giffuni, Jamie; Paden, Lydia; Morey, Miriam C; Katzel, Leslie

    2017-01-01

    The Veterans Health Administration's Care Assessment Need (CAN) score is a statistical model, aimed to predict high-risk patients. We were interested in determining if a relationship existed between physical function and CAN scores. Seventy-four older (71 ± 1 years) male Veterans underwent assessment of CAN score and subjective (Short Form-36 [SF-36]) and objective (self-selected walking speed, four square step test, short physical performance battery) assessment of physical function. Approximately 25% of participants self-reported limitations performing lower intensity activities, while 70% to 90% reported limitations with more strenuous activities. When compared with cut points indicative of functional limitations, 35% to 65% of participants had limitations for each of the objective measures. Any measure of subjective or objective physical function did not predict CAN score. These data indicate that the addition of a physical function assessment may complement the CAN score in the identification of high-risk patients.

  1. The book availability study as an objective measure of performance in a health sciences library.

    PubMed Central

    Kolner, S J; Welch, E C

    1985-01-01

    In its search for an objective overall diagnostic evaluation, the University of Illinois Library of the Health Sciences' Program Evaluation Committee selected a book availability measure; it is easy to administer and repeat, results are reproducible, and comparable data exist for other academic and health sciences libraries. The study followed the standard methodology in the literature with minor modifications. Patrons searching for particular books were asked to record item(s) needed and the outcome of the search. Library staff members then determined the reasons for failures in obtaining desired items. The results of the study are five performance scores. The first four represent the percentage probability of a library's operating with ideal effectiveness; the last provides an overall performance score. The scores of the Library of the Health Sciences demonstrated no unusual availability problems. The study was easy to implement and provided meaningful, quantitative, and objective data. PMID:3995202

  2. Accuracy of a smartphone to test laryngoscope's light and an audit to our laryngoscopes using an ISO standard.

    PubMed

    Machado, Diogo Alcino de Abreu Ribeiro Carvalho; Esteves, Dina da Assunção Azevedo; Branca, Pedro Manuel Araújo de Sousa

    Laryngoscope is a key tool in anesthetic practice. Direct laryngoscopy is a crucial moment and inadequate laryngoscope's light can lead to catastrophic consequences. From our experience laryngoscope's light is assessed in a subjective manner and we believe a more precise evaluation should be used. Our objective is to compare the accuracy of a smartphone compared to a lux meter. Secondly we audited our Operating Room laryngoscopes. We designed a pragmatic study, using as primary outcome the accuracy of a smartphone compared to the lux meter. Further we audited with both the lux meter and the smartphone all laryngoscopes and blades ready to use in our Operating Rooms, using the International Standard form the International Organization for Standardization. For primary outcome we found no significant difference between devices. Our audit showed that only 2 in 48 laryngoscopes complied with the ISO norm. When comparing the measurements between the lux meter and the smartphone we found no significant difference. Ideally every laryngoscope should perform as required. We believe all laryngoscopes should have a practical but reliable and objective test prior to its utilization. Our results suggest the smartphone was accurate enough to be used as a lux meter to test laryngoscope's light. Audit results showing only 4% comply with the ISO standard are consistent with other studies. The tested smartphone has enough accuracy to perform light measurement in laryngoscopes. We believe this is a step further to perform an objective routine check to laryngoscope's light. Copyright © 2016. Published by Elsevier Editora Ltda.

  3. Picture agnosia as a characteristic of posterior cortical atrophy.

    PubMed

    Sugimoto, Azusa; Midorikawa, Akira; Koyama, Shinichi; Futamura, Akinori; Hieda, Sotaro; Kawamura, Mitsuru

    2012-01-01

    Posterior cortical atrophy (PCA) is a degenerative disease characterized by progressive visual agnosia with posterior cerebral atrophy. We examine the role of the picture naming test and make a number of suggestions with regard to diagnosing PCA as atypical dementia. We investigated 3 cases of early-stage PCA with 7 control cases of Alzheimer disease (AD). The patients and controls underwent a naming test with real objects and colored photographs of familiar objects. We then compared rates of correct answers. Patients with early-stage PCA showed significant inability to recognize photographs compared to real objects (F = 196.284, p = 0.0000) as measured by analysis of variants. This difficulty was also significant to AD controls (F = 58.717, p = 0.0000). Picture agnosia is a characteristic symptom of early-stage PCA, and the picture naming test is useful for the diagnosis of PCA as atypical dementia at an early stage. Copyright © 2012 S. Karger AG, Basel.

  4. [Fundamental frequency analysis - a contribution to the objective examination of the speaking and singing voice (author's transl)].

    PubMed

    Schultz-Coulon, H J

    1975-07-01

    The applicability of a newly developed fundamental frequency analyzer to diagnosis in phoniatrics is reviewed. During routine voice examination, the analyzer allows a quick and accurate measurement of fundamental frequency and sound level of the speaking voice, and of vocal range and maximum phonation time. By computing fundamental frequency histograms, the median fundamental frequency and the total pitch range can be better determined and compared. Objective studies of certain technical faculties of the singing voice, which usually are estimated subjectively by the speech therapist, may now be done by means of this analyzer. Several examples demonstrate the differences between correct and incorrect phonation. These studies compare the pitch perturbations during the crescendo and decrescendo of a swell-tone, and show typical traces of staccato, thrill and yodel. Conclusions of the study indicate that fundamental frequency analysis is a valuable supplemental method for objective voice examination.

  5. Changes in quality of life after elective surgery: an observational study comparing two measures.

    PubMed

    Kronzer, Vanessa L; Jerry, Michelle R; Ben Abdallah, Arbi; Wildes, Troy S; McKinnon, Sherry L; Sharma, Anshuman; Avidan, Michael S

    2017-08-01

    Our main objective was to compare the change in a validated quality of life measure to a global assessment measure. The secondary objectives were to estimate the minimum clinically important difference (MCID) and to describe the change in quality of life by surgical specialty. This prospective cohort study included 7902 adult patients undergoing elective surgery. Changes in the Veterans RAND 12-Item Health Survey (VR-12), composed of a physical component summary (PCS) and a mental component summary (MCS), were calculated using preoperative and postoperative questionnaires. The latter also contained a global assessment question for quality of life. We compared PCS and MCS to the global assessment using descriptive statistics and weighted kappa. MCID was calculated using an anchor-based approach. Analyses were pre-specified and registered (NCT02771964). By the change in VR-12 scores, an equal proportion of patients experienced improvement and deterioration in quality of life (28% for PCS, 25% for MCS). In contrast, by the global assessment measure, 61% reported improvement, while only 10% reported deterioration. Agreement with the global assessment was slight for both PCS (kappa = 0.20, 57% matched) and MCS (kappa = 0.10, 54% matched). The MCID for the overall VR-12 score was approximately 2.5 points. Patients undergoing orthopedic surgery showed the most improvement in quality of life measures, while patients undergoing gastrointestinal/hepatobiliary or urologic surgery showed the most deterioration. Subjective global quality of life report does not agree well with a validated quality of life instrument, perhaps due to patient over-optimism.

  6. Heterochromatic Flicker Photometry for Objective Lens Density Quantification.

    PubMed

    Najjar, Raymond P; Teikari, Petteri; Cornut, Pierre-Loïc; Knoblauch, Kenneth; Cooper, Howard M; Gronfier, Claude

    2016-03-01

    Although several methods have been proposed to evaluate lens transmittance, to date there is no consensual in vivo approach in clinical practice. The aim of this study was to compare ocular lens density and transmittance measurements obtained by an improved psychophysical scotopic heterochromatic flicker photometry (sHFP) technique to the results obtained by three other measures: a psychophysical threshold technique, a Scheimpflug imaging technique, and a clinical assessment using a validated subjective scale. Forty-three subjects (18 young, 9 middle aged, and 16 older) were included in the study. Individual lens densities were measured and transmittance curves were derived from sHFP indexes. Ocular lens densities were compared across methods by using linear regression analysis. The four approaches showed a quadratic increase in lens opacification with age. The sHFP technique revealed that transmittance decreased with age over the entire visual spectrum. This decrease was particularly pronounced between young and older participants in the short (53.03% decrease in the 400-500 nm range) wavelength regions of the light spectrum. Lens density derived from sHFP highly correlated with the values obtained with the other approaches. Compared to other objective measures, sHFP also showed the lowest variability and the best fit with a quadratic trend (r2 = 0.71) of lens density increase as a function of age. The sHFP technique offers a practical, reliable, and accurate method to measure lens density in vivo and predict lens transmittance over the visible spectrum. An accurate quantification of lens transmittance should be obtained in clinical practice, but also in research in visual and nonvisual photoreception.

  7. Pilot study on objective measurement of abdominal wall strength in patients with ventral incisional hernia.

    PubMed

    Parker, Michael; Goldberg, Ross F; Dinkins, Maryane M; Asbun, Horacio J; Daniel Smith, C; Preissler, Susanne; Bowers, Steven P

    2011-11-01

    Outcomes after ventral incisional hernia (VIH) repair are measured by recurrence rate and subjective measures. No objective metrics evaluate functional outcomes after abdominal wall reconstruction. This study aimed to develop testing of abdominal wall strength (AWS) that could be validated as a useful metric. Data were prospectively collected during 9 months from 35 patients. A total of 10 patients were evaluated before and after VIH repair, for a total of 45 encounters. The patients were tested simultaneously or in succession by two of three examiners. Data were collected for three tests: double leg lowering (DLL), trunk raising (TR), and supine reaching (SR). Raw data were compared and tested for validity, and continuous data were transformed to categorical data. Agreement was measured using the intraclass correlation coefficient (ICC) for DLL and using kappa for the ordinal measures. Simultaneous testing yielded the following interobserver reliability: DLL (0.96 and 0.87), TR (1.00 and 0.95), and SR (0.76). Reproducibility was assessed by consecutive tests, with correlation as follows: DLL (0.81), TR (0.81), and RCH (0.21). Due to poor interobserver reliability for the SR test compared with the DLL and TR tests, the SR test was excluded from calculation of an overall score. Based on raw data distribution from the DLL and TR tests, the DLL data were categorized into 10º increments, allowing construction of a 10-point score. The median AWS score was 5 (interquartile range [IQR], 4-7), and there was agreement within 1 point for 42 of the 45 encounters (93%). The findings from this study demonstrate that the 10-point AWS score may measure AWS in an accurate and reproducible fashion, with potential for objective description of abdominal wall function of VIH patients. This score may help to identify patients suited for abdominal wall reconstruction while measuring progress after VIH repair. Further longitudinal outcomes studies are needed.

  8. Pressure-Flow Analysis for the Assessment of Pediatric Oropharyngeal Dysphagia.

    PubMed

    Ferris, Lara; Rommel, Nathalie; Doeltgen, Sebastian; Scholten, Ingrid; Kritas, Stamatiki; Abu-Assi, Rammy; McCall, Lisa; Seiboth, Grace; Lowe, Katie; Moore, David; Faulks, Jenny; Omari, Taher

    2016-10-01

    To determine which objective pressure-impedance measures of pharyngeal swallowing function correlated with clinically assessed severity of oropharyngeal dysphagia (OPD) symptoms. Forty-five children with OPD and 34 control children without OPD were recruited and up to 5 liquid bolus swallows were recorded with a solid-state high-resolution manometry with impedance catheter. Individual measures of pharyngeal and upper esophageal sphincter (UES) function and a swallow risk index composite score were derived for each swallow, and averaged data for patients with OPD were compared with those of control children without OPD. Clinical severity of OPD symptoms and oral feeding competency was based on the validated Dysphagia Disorders Survey and Functional Oral Intake Scale. Those objective measures that were markers of UES relaxation, UES opening, and pharyngeal flow resistance differentiated patients with and without OPD symptoms. Patients demonstrating abnormally high pharyngeal intrabolus pressures and high UES resistance, markers of outflow obstruction, were most likely to have signs and symptoms of overt Dysphagia Disorders Survey (OR 9.24, P = .05, and 9.7, P = .016, respectively). Pharyngeal motor patterns can be recorded in children by the use of HRIM and pharyngeal function can be defined objectively with the use of pressure-impedance measures. Objective measurements suggest that pharyngeal dysfunction is common in children with clinical signs of OPD. A key finding of this study was evidence of markers of restricted UES opening. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. OROS-methylphenidate efficacy on specific executive functioning deficits in adults with ADHD: a randomized, placebo-controlled cross-over study.

    PubMed

    Bron, Tannetje I; Bijlenga, Denise; Boonstra, A Marije; Breuk, Minda; Pardoen, Willem F H; Beekman, Aartjan T F; Kooij, J J Sandra

    2014-04-01

    Attention-deficit/hyperactivity disorder (ADHD) is linked to impaired executive functioning (EF). This is the first study to objectively investigate the effects of a long-acting methylphenidate on neurocognitive test performance of adults with ADHD. Twenty-two adults with ADHD participated in a 6-weeks study examining the effect of osmotic-release oral system methylphenidate (OROS-mph) on continuous performance tests (CPTs; objective measures), and on the self-reported ADHD rating scale (subjective measure) using a randomized, double-blind, placebo-controlled cross-over design. OROS-mph significantly improved reaction time variability (RTV), commission errors (CE) and d-prime (DP) as compared to baseline (Cohen's d>.50), but did not affect hit reaction time (HRT) or omission errors (OE). Compared to placebo, OROS-mph only significantly influenced RTV on one of two CPTs (p<.050). Linear regression analyses showed predictive ability of more beneficial OROS-mph effects in ADHD patients with higher EF severity (RTV: β=.670, t=2.097, p=.042; omission errors (OE): β=-.098, t=-4.759, p<.001), and with more severe ADHD symptoms (RTV: F=6.363, p=.019; HRT: F=3.914, p=.061). Side effects rates were substantially but non-significantly greater for OROS-mph compared to placebo (77% vs. 46%, p=.063). OROS-mph effects indicated RTV as the most sensitive parameter for measuring both neuropsychological and behavioral deficits in adults with ADHD. These findings suggest RTV as an endophenotypic parameter for ADHD symptomatology, and propose CPTs as an objective method for monitoring methylphenidate titration. Copyright © 2014 Elsevier B.V. and ECNP. All rights reserved.

  10. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools

    PubMed Central

    2013-01-01

    Background This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. Methods The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as <200 counts/15-second. The accelerometry data were summarized into the average minutes per hour spent in sedentary behavior during the in-school, the after-school, and the total-day period. Mixed linear regression models were used to determine differences in the average time spent in sedentary behavior between children attending traditional and Montessori preschools, after adjusting for selected potential correlates of preschoolers’ sedentary behavior. Results Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03), after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04), and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009) periods. School type (Montessori or traditional), preschool setting (private or public), socio-demographic factors (age, gender, and socioeconomic status) were found to be significant predictors of preschoolers’ sedentary behavior. Conclusions Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools. PMID:23286454

  11. Quantitative morphometrical characterization of human pronuclear zygotes.

    PubMed

    Beuchat, A; Thévenaz, P; Unser, M; Ebner, T; Senn, A; Urner, F; Germond, M; Sorzano, C O S

    2008-09-01

    Identification of embryos with high implantation potential remains a challenge in in vitro fertilization (IVF). Subjective pronuclear (PN) zygote scoring systems have been developed for that purpose. The aim of this work was to provide a software tool that enables objective measuring of morphological characteristics of the human PN zygote. A computer program was created to analyse zygote images semi-automatically, providing precise morphological measurements. The accuracy of this approach was first validated by comparing zygotes from two different IVF centres with computer-assisted measurements or subjective scoring. Computer-assisted measurement and subjective scoring were then compared for their ability to classify zygotes with high and low implantation probability by using a linear discriminant analysis. Zygote images coming from the two IVF centres were analysed with the software, resulting in a series of precise measurements of 24 variables. Using subjective scoring, the cytoplasmic halo was the only feature which was significantly different between the two IVF centres. Computer-assisted measurements revealed significant differences between centres in PN centring, PN proximity, cytoplasmic halo and features related to nucleolar precursor bodies distribution. The zygote classification error achieved with the computer-assisted measurements (0.363) was slightly inferior to that of the subjective ones (0.393). A precise and objective characterization of the morphology of human PN zygotes can be achieved by the use of an advanced image analysis tool. This computer-assisted analysis allows for a better morphological characterization of human zygotes and can be used for classification.

  12. Non-Invasive Imaging of Reactor Cores Using Cosmic Ray Muons

    NASA Astrophysics Data System (ADS)

    Milner, Edward

    2011-10-01

    Cosmic ray muons penetrate deeply in material, with some passing completely through very thick objects. This penetrating quality is the basis of two distinct, but related imaging techniques. The first measures the number of cosmic ray muons transmitted through parts of an object. Relatively fewer muons are absorbed along paths in which they encounter less material, compared to higher density paths, so the relative density of material is measured. This technique is called muon transmission imaging, and has been used to infer the density and structure of a variety of large masses, including mine overburden, volcanoes, pyramids, and buildings. In a second, more recently developed technique, the angular deflection of muons is measured by trajectory-tracking detectors placed on two opposing sides of an object. Muons are deflected more strongly by heavy nuclei, since multiple Coulomb scattering angle is approximately proportional to the nuclear charge. Therefore, a map showing regions of large deflection will identify the location of uranium in contrast to lighter nuclei. This technique is termed muon scattering tomography (MST) and has been developed to screen shipping containers for the presence of concealed nuclear material. Both techniques are a good way of non-invasively inspecting objects. A previously unexplored topic was applying MST to imaging large objects. Here we demonstrate extending the MST technique to the task of identifying relatively thick objects inside very thick shielding. We measured cosmic ray muons passing through a physical arrangement of material similar to a nuclear reactor, with thick concrete shielding and a heavy metal core. Newly developed algorithms were used to reconstruct an image of the ``mock reactor core,'' with resolution of approximately 30 cm.

  13. Dual physiological rate measurement instrument

    NASA Technical Reports Server (NTRS)

    Cooper, Tommy G. (Inventor)

    1990-01-01

    The object of the invention is to provide an instrument for converting a physiological pulse rate into a corresponding linear output voltage. The instrument which accurately measures the rate of an unknown rectangular pulse wave over an extended range of values comprises a phase-locked loop including a phase comparator, a filtering network, and a voltage-controlled oscillator, arranged in cascade. The phase comparator has a first input responsive to the pulse wave and a second input responsive to the output signal of the voltage-controlled oscillator. The comparator provides a signal dependent on the difference in phase and frequency between the signals appearing on the first and second inputs. A high-input impedance amplifier accepts an output from the filtering network and provides an amplified output DC signal to a utilization device for providing a measurement of the rate of the pulse wave.

  14. Photometric Studies of GEO Orbital Debris

    NASA Technical Reports Server (NTRS)

    Seitzer, Patrick; Rodriquez-Cowardin, Heather M.; Barker, Ed; Abercromby, Kira J.; Foreman, Gary; Horstman, Matt

    2009-01-01

    The photometric signature of a debris object can be useful in determining what the physical characteristics of a piece of debris are. We report on optical observations in multiple filters of debris at geosynchronous Earth orbit (GEO). Our sample is taken from GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the Cerro Tololo Inter- American Observatory (CTIO) 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R=15th magnitude that are discovered in the MODEST survey. At this magnitude the distribution of observed angular rates changes significantly from that of brighter objects. There are two objectives: 1. Estimate the orbital distribution of objects selected on the basis of two observational criteria: brightness (magnitude) and angular rates. 2. Obtain magnitudes and colors in standard astronomical filters (BVRI) for comparison with reflectance spectra of likely spacecraft materials. What is the faint debris likely to be? More than 90 calibrated sequences of R-B-V-I-R magnitudes for a sample of 50 objects have been obtained with the CTIO 0.9-m. For objects that do not show large brightness variations, the colors are largely redder than solar in both B-R and R-I. The width of the color distribution may be intrinsic to the nature of the surfaces, but also could be that we are seeing irregularly shaped objects and measuring the colors at different times with just one telescope. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and duration of observations are the same to better than 50 milliseconds. Thus the B-R color is a true measure of the surface of the debris piece facing the telescopes for that observation. Any change in color reflects a real change in the debris surface. We will compare our observations with models and laboratory measurements of selected surfaces.

  15. Psychological and autonomic effects of art making in college-aged students.

    PubMed

    Sandmire, David A; Rankin, Nancy E; Gorham, Sarah R; Eggleston, Daniel T; French, Cecelia A; Lodge, Emily E; Kuns, Gavin C; Grimm, David R

    2016-09-01

    Anxiety disorders comprise the most common category of mental illness among US young adults. Art making might be one method to help reduce anxiety, but the few studies investigating this have used only subjective measures of anxiety. This study employed both subjective (self-reported state anxiety from the State-Trait Anxiety Inventory) and objective (heart rate variability) measures to assess whether 30-minute periods of art making reduced anxiety in 47 first-year college students prior to their final examinations. Students participated in free-form painting, mandala coloring, clay modeling, and control sessions. Repeated-measures ANOVA with post hoc analysis revealed significantly greater pre- to post-session reductions in anxiety for all three types of art-making sessions than for the control session, as measured objectively. Measured subjectively, only free-form painting yielded a significant decrease in anxiety compared to the control session. Given the health benefits of anxiety reduction, further study is warranted to determine the duration of art making's anxiety-reducing effect.

  16. Fourteen-month-olds selectively search for and use information depending on the familiarity of the informant in both laboratory and home contexts.

    PubMed

    Schieler, Andy; Koenig, Melissa; Buttelmann, David

    2018-06-20

    Infants are selective in their learning from others. However, there is only very limited research on the possible factors that shape this selectivity, especially when it comes to the impact of infants' familiarity with the informant and the context. The current study investigated whether 14-month-olds preferred to receive and use information provided by an unfamiliar informant (experimenter) compared with a familiar informant (parent) and whether this pattern depended on the context (home vs. laboratory). We tested infants either in the laboratory (n = 67) or in their home (n = 70). When both informants presented a novel object with positive or negative emotions, we measured infants' gaze behavior as an indicator for information search. When infants acted on the novel object themselves, we measured their exploratory behavior as an indicator of information use. Results revealed no effect of context on infants' information search and use. Rather, we found that the familiarity of informant had distinct effects on infant attention and object exploration. Namely, infants looked longer at the unfamiliar informant across contexts, but they explored more when the familiar informant presented the object compared with when the unfamiliar informant did so. Thus, during information search, 14-month-olds paid most attention to an unfamiliar source of information. However, participants explored the objects more when they came from a familiar source than when they came from an unfamiliar one. Possible explanations for these findings are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. The late positive potential (LPP) in response to varying types of emotional and cigarette stimuli in smokers: a content comparison.

    PubMed

    Minnix, Jennifer A; Versace, Francesco; Robinson, Jason D; Lam, Cho Y; Engelmann, Jeffrey M; Cui, Yong; Brown, Victoria L; Cinciripini, Paul M

    2013-07-01

    Identifying neural mechanisms associated with addiction has substantially improved the overall understanding of addictive processes. Indeed, research suggests that drug-associated cues may take advantage of neural mechanisms originally intended for emotional processing of stimuli relevant to survival. In this study, we investigated cortical responses to several categories of emotional cues (erotic, romance, pleasant objects, mutilation, sadness, and unpleasant objects) as well as two types of smoking-related cues (people smoking and cigarette-related objects). We recorded ERPs from 180 smokers prior to their participation in a smoking cessation clinical trial and assessed emotional salience by measuring the amplitude of the late positive potential (LPP; 400 to 600 ms after picture onset). As expected, emotional and cigarette-related pictures prompted a significantly larger LPP than neutral pictures. The amplitude of the LPP increased as a function of picture arousal level, with high-arousing erotic and mutilation pictures showing the largest response in contrast to low-arousing pleasant and unpleasant objects, which showed the smallest response (other than neutral). Compared to females, male participants showed larger LPPs for high-arousing erotic and mutilation pictures. However, unlike emotional pictures, no difference was noted for the LPP between cigarette stimuli containing people versus those containing only objects, suggesting that in contrast to emotional objects, cigarette-related objects are highly relevant for smokers. We also compared the smokers to a small (N=40), convenience sample of never-smokers. We found that never-smokers had significantly smaller LPPs in response to erotic and cigarette stimuli containing only objects compared to smokers. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Perception of faces in schizophrenia: Subjective (self-report) vs. objective (psychophysics) assessments

    PubMed Central

    Chen, Yue; Ekstrom, Tor

    2016-01-01

    Objectives Face perception impairment in schizophrenia has been demonstrated, mostly through experimental studies. How this laboratory-defined behavioral impairment is associated with patients’ perceptual experience of various faces in everyday life is however unclear. This question is important because a first-person account of face perception has direct consequences on social functioning of patients. In this study, we adapted and administered a self-reported questionnaire on narrative perceptual experience of faces along with psychophysical assessments of face perception in schizophrenia. Methods The self-reported questionnaire includes six rating items of face-related functioning in everyday life, providing a subjective measure of face perception. The psychophysical assessment determines perceptual threshold for discriminating different facial identities, providing an objective measure of face perception. Results Compared to controls (n=25), patients (n=35) showed significantly lower scores (worse performance) in the subjective assessment and significantly higher thresholds (worse performance) in the objective assessment. The subjective and objective face perception assessments were moderately correlated in controls but not in patients. The subjective face perception assessments were significantly correlated with measurements of a social cognitive ability (Theory of Mind), again in controls but not in patients. Conclusion These results suggest that in schizophrenia the quality of face-related functioning in everyday life is degraded and the role that basic face discrimination capacity plays in face-related everyday functioning is disrupted. PMID:26938027

  19. Posters in a sample of professional worksites have no effect on objectively measured physical activity.

    PubMed

    Badland, Hannah M; Schofield, Grant M

    2005-04-01

    Whether posters promoting stair use are effective in increasing objectively measured physical activity in a sample of New Zealand professional employees. Forty-six participants (27 men and 19 women) recruited from two professional worksites wore one sealed pedometer during all waking hours (total physical activity [TPV]), and another sealed pedometer during working hours (worksite physical activity [WPV]), for three days over four separate occasions. The study protocol was a crossover design with the first worksite receiving the treatment (posters) for three weeks, followed by a six-week washout period, then a three-week control. The second worksite received the control prior to the treatment period. Measurements were taken at the beginning and end of each three-week block. The posters were ineffective at increasing objectively measured work and total physical activity levels in this sample. Trivial (0.04) to moderate Cohen effect sizes (-0.79) were shown. When posters were visible in the worksites, mean step counts decreased (-868 steps [WPV], and -1,861 steps [TPV]). Women's step counts (-9% [WPV] and -13% [TPV]) were more negatively affected by the posters' appearance when compared with men (-2% [WPV] and -8% [TPV]).

  20. Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs.

    PubMed

    Goossen, A; Weber, G M; Dries, S P M

    2012-01-01

    For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs. In a two step approach we first detect and segment any implants or other artificial objects within the image. We exploit physical characteristics and avoid prior shape information to cope with the vast amount of implant types. Subsequently, we exploit the implant delineations to adapt the initialization and adaptation phase of a dedicated bone segmentation scheme using deformable template models. Implant and bone contours are fused to derive the final joint segmentation and thus the alignment measurements. We evaluated our method on clinical long leg radiographs and compared both the initialization rate, corresponding to the number of images successfully processed by the proposed algorithm, and the accuracy of the alignment measurement. Ground truth has been generated by an experienced orthopedic surgeon. For comparison a second reader reevaluated the measurements. Experiments on two sets of 70 and 120 digital radiographs show that 92% of the joints could be processed automatically and the derived measurements of the automatic method are comparable to a human reader for pre-operative as well as post-operative images with a typical error of 0.7° and correlations of r = 0.82 to r = 0.99 with the ground truth. The proposed method allows deriving objective measures of joint alignment from clinical radiographs. Its accuracy and precision are on par with a human reader for all evaluated measurements.

  1. A verification and errors analysis of the model for object positioning based on binocular stereo vision for airport surface surveillance

    NASA Astrophysics Data System (ADS)

    Wang, Huan-huan; Wang, Jian; Liu, Feng; Cao, Hai-juan; Wang, Xiang-jun

    2014-12-01

    A test environment is established to obtain experimental data for verifying the positioning model which was derived previously based on the pinhole imaging model and the theory of binocular stereo vision measurement. The model requires that the optical axes of the two cameras meet at one point which is defined as the origin of the world coordinate system, thus simplifying and optimizing the positioning model. The experimental data are processed and tables and charts are given for comparing the positions of objects measured with DGPS with a measurement accuracy of 10 centimeters as the reference and those measured with the positioning model. Sources of visual measurement model are analyzed, and the effects of the errors of camera and system parameters on the accuracy of positioning model were probed, based on the error transfer and synthesis rules. A conclusion is made that measurement accuracy of surface surveillances based on binocular stereo vision measurement is better than surface movement radars, ADS-B (Automatic Dependent Surveillance-Broadcast) and MLAT (Multilateration).

  2. Fragmentation of Solid Materials Using Shock Tubes. Part 1: First Test Series in a Small Diameter Shock Tube

    DTIC Science & Technology

    2017-01-01

    time histories with peak pressures of approximately 250 psi and 500 psi. 1.2 TESTING OBJECTIVES The first goal of this test series was to explore how...finally the late- time at-rest fragments were physically collected and analyzed post-test. Because this test series physically collected over 50,000...for a single fragmenting object. Comparing the three measurement techniques used in this test series , the late- time physically- collected mass

  3. Smartphone-Based Self-Assessment of Stress in Healthy Adult Individuals: A Systematic Review.

    PubMed

    Þórarinsdóttir, Helga; Kessing, Lars Vedel; Faurholt-Jepsen, Maria

    2017-02-13

    Stress is a common experience in today's society. Smartphone ownership is widespread, and smartphones can be used to monitor health and well-being. Smartphone-based self-assessment of stress can be done in naturalistic settings and may potentially reflect real-time stress level. The objectives of this systematic review were to evaluate (1) the use of smartphones to measure self-assessed stress in healthy adult individuals, (2) the validity of smartphone-based self-assessed stress compared with validated stress scales, and (3) the association between smartphone-based self-assessed stress and smartphone generated objective data. A systematic review of the scientific literature was reported and conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement. The scientific databases PubMed, PsycINFO, Embase, IEEE, and ACM were searched and supplemented by a hand search of reference lists. The databases were searched for original studies involving healthy individuals older than 18 years, measuring self-assessed stress using smartphones. A total of 35 published articles comprising 1464 individuals were included for review. According to the objectives, (1) study designs were heterogeneous, and smartphone-based self-assessed stress was measured using various methods (e.g., dichotomized questions on stress, yes or no; Likert scales on stress; and questionnaires); (2) the validity of smartphone-based self-assessed stress compared with validated stress scales was investigated in 3 studies, and of these, only 1 study found a moderate statistically significant positive correlation (r=.4; P<.05); and (3) in exploratory analyses, smartphone-based self-assessed stress was found to correlate with some of the reported smartphone generated objective data, including voice features and data on activity and phone usage. Smartphones are being used to measure self-assessed stress in different contexts. The evidence of the validity of smartphone-based self-assessed stress is limited and should be investigated further. Smartphone generated objective data can potentially be used to monitor, predict, and reduce stress levels. ©Helga Þórarinsdóttir, Lars Vedel Kessing, Maria Faurholt-Jepsen. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 13.02.2017.

  4. Object-based change detection method using refined Markov random field

    NASA Astrophysics Data System (ADS)

    Peng, Daifeng; Zhang, Yongjun

    2017-01-01

    In order to fully consider the local spatial constraints between neighboring objects in object-based change detection (OBCD), an OBCD approach is presented by introducing a refined Markov random field (MRF). First, two periods of images are stacked and segmented to produce image objects. Second, object spectral and textual histogram features are extracted and G-statistic is implemented to measure the distance among different histogram distributions. Meanwhile, object heterogeneity is calculated by combining spectral and textual histogram distance using adaptive weight. Third, an expectation-maximization algorithm is applied for determining the change category of each object and the initial change map is then generated. Finally, a refined change map is produced by employing the proposed refined object-based MRF method. Three experiments were conducted and compared with some state-of-the-art unsupervised OBCD methods to evaluate the effectiveness of the proposed method. Experimental results demonstrate that the proposed method obtains the highest accuracy among the methods used in this paper, which confirms its validness and effectiveness in OBCD.

  5. Like a rolling stone: naturalistic visual kinematics facilitate tracking eye movements.

    PubMed

    Souto, David; Kerzel, Dirk

    2013-02-06

    Newtonian physics constrains object kinematics in the real world. We asked whether eye movements towards tracked objects depend on their compliance with those constraints. In particular, the force of gravity constrains round objects to roll on the ground with a particular rotational and translational motion. We measured tracking eye movements towards rolling objects. We found that objects with rotational and translational motion that was congruent with an object rolling on the ground elicited faster tracking eye movements during pursuit initiation than incongruent stimuli. Relative to a condition without rotational component, we compared objects with this motion with a condition in which there was no rotational component, we essentially obtained benefits of congruence, and, to a lesser extent, costs from incongruence. Anticipatory pursuit responses showed no congruence effect, suggesting that the effect is based on visually-driven predictions, not on velocity storage. We suggest that the eye movement system incorporates information about object kinematics acquired by a lifetime of experience with visual stimuli obeying the laws of Newtonian physics.

  6. Polarization microscopy by use of digital holography: application to optical-fiber birefringence measurements.

    PubMed

    Colomb, Tristan; Dürr, Florian; Cuche, Etienne; Marquet, Pierre; Limberger, Hans G; Salathé, René-Paul; Depeursinge, Christian

    2005-07-20

    We present a digital holographic microscope that permits one to image polarization state. This technique results from the coupling of digital holographic microscopy and polarization digital holography. The interference between two orthogonally polarized reference waves and the wave transmitted by a microscopic sample, magnified by a microscope objective, is recorded on a CCD camera. The off-axis geometry permits one to reconstruct separately from this single hologram two wavefronts that are used to image the object-wave Jones vector. We applied this technique to image the birefringence of a bent fiber. To evaluate the precision of the phase-difference measurement, the birefringence induced by internal stress in an optical fiber is measured and compared to the birefringence profile captured by a standard method, which had been developed to obtain high-resolution birefringence profiles of optical fibers.

  7. Strength characterization of knee flexor and extensor muscles in Prader-Willi and obese patients.

    PubMed

    Capodaglio, Paolo; Vismara, Luca; Menegoni, Francesco; Baccalaro, Gabriele; Galli, Manuela; Grugni, Graziano

    2009-05-06

    despite evidence of an obesity-related disability, there is a lack of objective muscle functional data in overweight subjects. Only few studies provide instrumental strength measurements in non-syndromal obesity, whereas no data about Prader-Willi syndrome (PWS) are reported. The aim of our study was to characterize the lower limb muscle function of patients affected by PWS as compared to non-syndromal obesity and normal-weight subjects. We enrolled 20 obese (O) females (age: 29.1 +/- 6.5 years; BMI: 38.1 +/- 3.1), 6 PWS females (age: 27.2 +/- 4.9 years; BMI: 45.8 +/- 4.4) and 14 healthy normal-weight (H) females (age: 30.1 +/- 4.7 years; BMI: 21 +/- 1.6). Isokinetic strength during knee flexion and extension in both lower limbs at the fixed angular velocities of 60 degrees /s, 180 degrees /s, 240 degrees /s was measured with a Cybex Norm dynamometer. the H, O and PWS populations appear to be clearly stratified with regard to muscle strength.: PWS showed the lowest absolute peak torque (PT) for knee flexor and extensor muscles as compared to O (-55%) and H (-47%) (P = 0.00001). O showed significantly higher strength values than H as regard to knee extension only (P = 0.0014). When strength data were normalised by body weight, PWS showed a 50% and a 70% reduction in PT as compared to O and H, respectively. Knee flexors strength values were on average half of those reported for extension in all of the three populations. the novel aspect of our study is the determination of objective measures of muscle strength in PWS and the comparison with O and H patients. The objective characterization of muscle function performed in this study provides baseline and outcome measures that may quantify specific strength deficits amendable with tailored rehabilitation programs and monitor effectiveness of treatments.

  8. Strength characterization of knee flexor and extensor muscles in Prader-Willi and obese patients

    PubMed Central

    Capodaglio, Paolo; Vismara, Luca; Menegoni, Francesco; Baccalaro, Gabriele; Galli, Manuela; Grugni, Graziano

    2009-01-01

    Background despite evidence of an obesity-related disability, there is a lack of objective muscle functional data in overweight subjects. Only few studies provide instrumental strength measurements in non-syndromal obesity, whereas no data about Prader-Willi syndrome (PWS) are reported. The aim of our study was to characterize the lower limb muscle function of patients affected by PWS as compared to non-syndromal obesity and normal-weight subjects. Methods We enrolled 20 obese (O) females (age: 29.1 ± 6.5 years; BMI: 38.1 ± 3.1), 6 PWS females (age: 27.2 ± 4.9 years; BMI: 45.8 ± 4.4) and 14 healthy normal-weight (H) females (age: 30.1 ± 4.7 years; BMI: 21 ± 1.6). Isokinetic strength during knee flexion and extension in both lower limbs at the fixed angular velocities of 60°/s, 180°/s, 240°/s was measured with a Cybex Norm dynamometer. Results the H, O and PWS populations appear to be clearly stratified with regard to muscle strength.: PWS showed the lowest absolute peak torque (PT) for knee flexor and extensor muscles as compared to O (-55%) and H (-47%) (P = 0.00001). O showed significantly higher strength values than H as regard to knee extension only (P = 0.0014). When strength data were normalised by body weight, PWS showed a 50% and a 70% reduction in PT as compared to O and H, respectively. Knee flexors strength values were on average half of those reported for extension in all of the three populations. Conclusion the novel aspect of our study is the determination of objective measures of muscle strength in PWS and the comparison with O and H patients. The objective characterization of muscle function performed in this study provides baseline and outcome measures that may quantify specific strength deficits amendable with tailored rehabilitation programs and monitor effectiveness of treatments. PMID:19419559

  9. Efficiencies for the statistics of size discrimination.

    PubMed

    Solomon, Joshua A; Morgan, Michael; Chubb, Charles

    2011-10-19

    Different laboratories have achieved a consensus regarding how well human observers can estimate the average orientation in a set of N objects. Such estimates are not only limited by visual noise, which perturbs the visual signal of each object's orientation, they are also inefficient: Observers effectively use only √N objects in their estimates (e.g., S. C. Dakin, 2001; J. A. Solomon, 2010). More controversial is the efficiency with which observers can estimate the average size in an array of circles (e.g., D. Ariely, 2001, 2008; S. C. Chong, S. J. Joo, T.-A. Emmanouil, & A. Treisman, 2008; K. Myczek & D. J. Simons, 2008). Of course, there are some important differences between orientation and size; nonetheless, it seemed sensible to compare the two types of estimate against the same ideal observer. Indeed, quantitative evaluation of statistical efficiency requires this sort of comparison (R. A. Fisher, 1925). Our first step was to measure the noise that limits size estimates when only two circles are compared. Our results (Weber fractions between 0.07 and 0.14 were necessary for 84% correct 2AFC performance) are consistent with the visual system adding the same amount of Gaussian noise to all logarithmically transduced circle diameters. We exaggerated this visual noise by randomly varying the diameters in (uncrowded) arrays of 1, 2, 4, and 8 circles and measured its effect on discrimination between mean sizes. Efficiencies inferred from all four observers significantly exceed 25% and, in two cases, approach 100%. More consistent are our measurements of just-noticeable differences in size variance. These latter results suggest between 62 and 75% efficiency for variance discriminations. Although our observers were no more efficient comparing size variances than they were at comparing mean sizes, they were significantly more precise. In other words, our results contain evidence for a non-negligible source of late noise that limits mean discriminations but not variance discriminations.

  10. Artificial sweeteners versus regular mixers increase breath alcohol concentrations in male and female social drinkers

    PubMed Central

    Marczinski, Cecile A.; Stamates, Amy L.

    2012-01-01

    Background Limited research suggests that alcohol consumed with an artificially sweetened mixer (e.g., diet soft drink) results in higher breath alcohol concentrations (BrACs) compared to the same amount of alcohol consumed with a similar beverage containing sugar. The purpose of this study was to determine the reliability of this effect in both male and female social drinkers and to determine if there are measureable objective and subjective differences when alcohol is consumed with an artificially-sweetened versus sugar-sweetened mixer. Methods Participants (n = 16) of equal gender attended three sessions where they received one of 3 doses (1.97 ml/kg vodka mixed with 3.94 ml/kg Squirt, 1.97 ml/kg vodka mixed with 3.94 ml/kg diet Squirt, and a placebo beverage) in random order. BrACs were recorded, as was self-reported ratings of subjective intoxication, fatigue, impairment and willingness to drive. Objective performance was assessed using a cued go/no-go reaction time task. Results BrACs were significantly higher in the alcohol + diet beverage condition compared with the alcohol + regular beverage condition. The mean peak BrAC was .091 g/210 L in the alcohol + diet condition compared to .077 g/210 L in the alcohol + regular condition. Cued go/no-go task performance indicated the greatest impairment for the alcohol + diet beverage condition. Subjective measures indicated that participants appeared unaware of any differences in the two alcohol conditions, given that no significant differences in subjective ratings were observed for the two alcohol conditions. No gender differences were observed for BrACs, objective and subjective measures. Conclusions Mixing alcohol with a diet soft drink resulted in elevated BrACs, as compared to the same amount of alcohol mixed with a sugar sweetened beverage. Individuals were unaware of these differences, a factor that may increase the safety risks associated with drinking alcohol. PMID:23216417

  11. Associations between self-reported and objectively measured physical activity, sedentary behavior and overweight/obesity in NHANES 2003-2006.

    PubMed

    Wanner, M; Richard, A; Martin, B; Faeh, D; Rohrmann, S

    2017-01-01

    To investigate associations between self-reported and objectively measured physical activity, sedentary behavior and overweight/obesity based on percent body fat measured with Dual Energy X-Ray Absorptiometry (DXA), waist circumference (WC), waist-to-height ratio and body mass index, focusing on different intensities and domains of physical activity. Data from NHANES 2003-2006 were analyzed using linear and ordered logistic regression analyses. A total of 4794 individuals aged 18-69 years with valid physical activity and DXA data were included. Objectively measured physical activity and sedentary behavior were assessed using accelerometers, self-reported physical activity using the NHANES physical activity questionnaire. Weight, height, WC and DXA measures were assessed in the mobile examination centers. We observed statistically significant associations between objectively measured moderate and vigorous physical activity and all definitions of overweight/obesity. For total physical activity, the odds of being in the higher percent body fat category were 0.56 (95% confidence interval (CI) 0.41, 0.77) for the medium and 0.30 (95% CI 0.22, 0.40) for the highest physical activity tertile compared with the lowest. For light activities, lifestyle activities and sedentary behavior, associations were only observed in the linear models with percent total body fat but not in the ordered logistic regression models. Regarding self-reported physical activity, consistent significant associations with overweight/obesity were only observed for vigorous and for transport activity. Regarding moderate and vigorous physical activity, more active individuals were less affected by overweight/obesity than less active individuals, emphasizing the public health effect of physical activity in the prevention of overweight/obesity. The fact that associations were more consistent for objectively measured than for self-reported physical activity may be due to bias related to self-reporting. Associations between lower intensity activities and overweight/obesity were weak or inexistent.

  12. Twin study on heritability of activity, attention, and impulsivity as assessed by objective measures.

    PubMed

    Heiser, Philip; Heinzel-Gutenbrunner, Monika; Frey, Joachim; Smidt, Judith; Grabarkiewicz, Justyna; Friedel, Susann; Kühnau, Wolfgang; Schmidtke, Jörg; Remschmidt, Helmut; Hebebrand, Johannes

    2006-05-01

    The purpose of this study was to assess heritability of activity, attention, and impulsivity by comparing young monozygotic (MZ) twins with dizygotic (DZ) twins using objective measures. The OPTAx test is an infrared motion analysis to record the movement pattern during a continuous performance test. Seventeen MZ and 12 same sexed DZ twin pairs in the range of 6 to 12 years were tested. The zygosity was determined by DNA-fingerprinting. The measures under investigation were activity (microevents and spatial scaling), impulsivity (errors of commission), and attention (accuracy and variability). For statistical analyses, the classical model of Falconer and the ACE and ADE genetic model for twin data were applied in order to estimate the proportion of the variance in activity, impulsivity and attention that is due to genetic effects. The respective coefficients of intraclass correlations in MZ twins ranged between .35 and .65 whereas for DZ twins the correlations were between .12 and .88. The heritability estimates resulting from both models were about 30% for 4 of the 5 measures, but none of these was significantly different from 0. We found no significant influence of genetic factors for activity, attention, and impulsivity. The authors conclude that further investigation of heritability of ADHD is necessary using larger sample sizes and objective measures.

  13. Planned flight test of a mercury ion auxiliary propulsion system. Part 2: Integration with host spacecraft

    NASA Technical Reports Server (NTRS)

    Knight, R. M.

    1978-01-01

    The objectives of the flight test and a description on how those objectives are in support of an overall program goal of attaining user application were described. The approach to accomplishment was presented as it applies to integrating the propulsion system with the host spacecraft. A number of known interface design considerations which affect the propulsion system and the spacecraft were discussed. Analogies were drawn comparing the relationship of the organizations involved with this flight test with those anticipated for future operational missions. The paper also expanded upon objectives, system description, mission operations, and measurement of plume effects.

  14. 3D reconstruction of hollow parts analyzing images acquired by a fiberscope

    NASA Astrophysics Data System (ADS)

    Icasio-Hernández, Octavio; Gonzalez-Barbosa, José-Joel; Hurtado-Ramos, Juan B.; Viliesid-Alonso, Miguel

    2014-07-01

    A modified fiberscope used to reconstruct difficult-to-reach inner structures is presented. By substituting the fiberscope’s original illumination system, we can project a profile-revealing light line inside the object of study. The light line is obtained using a sandwiched power light-emitting diode (LED) attached to an extension arm on the tip of the fiberscope. Profile images from the interior of the object are then captured by a camera attached to the fiberscope’s eyepiece. Using a series of those images at different positions, the system is capable of generating a 3D reconstruction of the object with submillimeter accuracy. Also proposed is the use of a combination of known filters to remove the honeycomb structures produced by the fiberscope and the use of ring gages to obtain the extrinsic parameters of the camera attached to the fiberscope and the metrological traceability of the system. Several standard ring diameter measurements were compared against their certified values to improve the accuracy of the system. To exemplify an application, a 3D reconstruction of the interior of a refrigerator duct was conducted. This reconstruction includes accuracy assessment by comparing the measurements of the system to a coordinate measuring machine. The system, as described, is capable of 3D reconstruction of the interior of objects with uniform and non-uniform profiles from 10 to 60 mm in transversal dimensions and a depth of 1000 mm if the material of the walls of the object is translucent and allows the detection of the power LED light from the exterior through the wall. If this is not possible, we propose the use of a magnetic scale which reduces the working depth to 170 mm. The assessed accuracy is around ±0.15 mm in 2D cross-section reconstructions and ±1.3 mm in 1D position using a magnetic scale, and ±0.5 mm using a CCD camera.

  15. Large Ice Discharge From the Greenland Ice Sheet

    NASA Technical Reports Server (NTRS)

    Rignot, Eric

    1999-01-01

    The objectives of this work are to measure the ice discharge of the Greenland Ice Sheet close to the grounding line and/or calving front, and compare the results with mass accumulation and ablation in the interior to estimate the ice sheet mass balance.

  16. Treating Depression during Pregnancy and the Postpartum: A Preliminary Meta-Analysis

    ERIC Educational Resources Information Center

    Bledsoe, Sarah E.; Grote, Nancy K.

    2006-01-01

    Objectives: This meta-analysis evaluates treatment effects for nonpsychotic major depression during pregnancy and postpartum comparing interventions by type and timing. Methods: Studies for decreasing depressive severity during pregnancy and postpartum applying treatment trials and standardized measures were included. Standardized mean differences…

  17. Cultural competency, race, and skin tone bias among pharmacy, nursing, and medical students: implications for addressing health disparities.

    PubMed

    White-Means, Shelley; Zhiyong Dong; Hufstader, Meghan; Brown, Lawrence T

    2009-08-01

    The Institute of Medicine report, Unequal Treatment, asserts that conscious and unconscious bias of providers may affect treatments delivered and contribute to health disparities. The primary study objective is to measure, compare, and contrast objective and subjective cognitive processes among pharmacy, nursing, and medical students to discern potential implications for health disparities. Data were collected using a cultural competency questionnaire and two implicit association tests (IATs). Race and skin tone IATs measure unconscious bias. Cultural competency scores were significantly higher for non-Hispanic Blacks and Hispanics in medicine and pharmacy compared with non-Hispanic Whites. Multiracial nursing students also had significantly higher cultural competency scores than non-Hispanic Whites. The IAT results indicate that these health care preprofessionals exhibit implicit race and skin tone biases: preferences for Whites versus Blacks and light skin versus dark skin. Cultural competency curricula and disparities research will be advanced by understanding the factors contributing to cultural competence and bias.

  18. Neighbourhood crime and smoking: the role of objective and perceived crime measures

    PubMed Central

    2011-01-01

    Background Smoking is a major public health problem worldwide. Research has shown that neighbourhood of residence is independently associated with the likelihood of individuals' smoking. However, a fine comprehension of which neighbourhood characteristics are involved and how remains limited. In this study we examine the relative contribution of objective (police-recorded) and subjective (resident-perceived) measures of neighbourhood crime on residents' smoking behaviours. Methods Data from 2,418 men and women participating in the 2007/8 sweep of the West of Scotland Twenty-07 Study were analyzed. Smoking status and perceived crime were collected through face-to-face interviews with participants. Police-recorded crime rates were obtained from the Scottish Neighbourhood Statistics website at the datazone scale. Adjusted odds ratios and 95% confidence intervals were estimated for the likelihood of current smoking using logistic regression models. Adjusted mean daily amount smoked and F statistics were calculated using general linear models. Analyses were conducted for all respondents and stratified by sex and age cohort. Results Compared to individuals living in low crime areas, those residing in an area characterized by high police-recorded crime rates or those perceiving high crime in their neighbourhood were more likely to be current smokers, after controlling for individual characteristics. The association with smoking was somewhat stronger for police-recorded crime than for perceived crime. Associations were only slightly attenuated when adjusting for either the objective or subjective crime measures, suggesting that these indicators may exert an independent influence on the risk of smoking. Stronger effects were observed for women compared to men. Police-recorded crime rates were more strongly related to smoking status among older respondents than among the younger cohort, whereas the strongest effect for perceived crime was observed among younger participants. Conclusions Our findings highlight the relevance of paying attention to both objective and perceived neighbourhood crime measures when aiming to prevent smoking. PMID:22168151

  19. Cadmium content of Cameroonian cigarettes: Comparison with other foreign brands sold in Cameroon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamboue, H.S.; Tamboue, E.D.; Leno, M.

    Given the increasing concern about heavy metal and in particular cadmium toxicity, the present study has two objectives. First, the authors wanted to measure and compare the amount of cadmium found in Cameroonian cigarettes and in foreign brands sold in Cameroon. Secondly, they measured the amount of cadmium in smoke, ashes and the amount retained by filters of some Cameroonian cigarettes after using a smoking machine.

  20. Double Star Measurements at the Internationale Amateur Sternwarte (IAS) in Namibia in 2008 and 2009

    NASA Astrophysics Data System (ADS)

    Anton, Rainer

    2010-04-01

    A 40-cm-Cassegrain telescope in Namibia was used for observing double and multiple systems in the southern sky. Digital images were recorded with a CCD camera at high frame rates via a firewire interface directly in a computer. Measurements of 34 double and multiple systems are presented and compared with literature data. Some noteworthy objects are discussed in more detail.

  1. Object's optical geometry measurements based on Extended Depth of Field (EDoF) approach

    NASA Astrophysics Data System (ADS)

    Szydłowski, Michał; Powałka, Bartosz; Chady, Tomasz; Waszczuk, Paweł

    2017-02-01

    The authors propose a method of using EDoF in macro inspections using bi-telecentric lenses and a specially designed experimental machine setup, allowing accurate focal distance changing. Also a software method is presented allowing EDoF image reconstruction using the continuous wavelet transform (CWT). Exploited method results are additionally compared with measurements performed with Keyence's LJ-V Series in-line Profilometer for reference matters.

  2. Radiographic measurement of internal organs in Spix's macaws (Cyanopsitta spixii).

    PubMed

    Rettmer, Helen; Deb, Amrita; Watson, Ryan; Hatt, Jean-Michel; Hammer, Sven

    2011-12-01

    Radiology is an important diagnostic instrument in avian medicine, but standard measurement ranges for the objective evaluation of radiographs of birds are rare. To establish radiographic reference ranges for the critically endangered Spix's macaw (Cyanopsitta spixii), we measured radiographic silhouettes of the heart, liver, kidneys, spleen, proventriculus, and keel of the sternum on 29 radiographs taken under standardized conditions in adult and juvenile, clinically healthy birds. Ratios were determined for the proventricular diameter-to-keel height, the width of the heart to the width of the thorax, and for the "hourglass shape" (ratio of the width of the heart to the width of the liver). No significant differences were found between the sexes among the adult birds. Compared with adult birds, juvenile females had a significantly larger heart width (19.8 +/- 1.4 mm versus 21.2 +/- 0.7 mm), ratio of the heart width to the thorax width (0.86 +/- 0.08 versus 0.94 +/- 0.09), and horizontal width of the spleen (7.7 +/- 0.6 mm versus 8.5 +/- 0.4 mm). Results of radiographic measurements in the Spix's macaws were comparable to those published from other psittacine species. These reference ranges will facilitate a more objective radiographic evaluation of captive Spix's macaws.

  3. The Longitudinal Relationship between Fatigue and Sleep in Breast Cancer Patients Undergoing Chemotherapy

    PubMed Central

    Liu, Lianqi; Rissling, Michelle; Natarajan, Loki; Fiorentino, Lavinia; Mills, Paul J.; Dimsdale, Joel E.; Sadler, Georgia Robins; Parker, Barbara A.; Ancoli-Israel, Sonia

    2012-01-01

    Study Objective: Fatigue and sleep disturbances are two of the most common and distressing symptoms of cancer patients. A relationship between the two symptoms was reported in symptom cluster studies; however, only subjective measurements of sleep were examined and most studies were cross-sectional. In this study of women with breast cancer undergoing chemotherapy, we explored the longitudinal relationship between fatigue and sleep measured both subjectively and objectively. Design: Prospective study. Data were collected at 7 time points: before (baseline) and during the 3 weeks of cycle 1 and cycle 4 chemotherapy. Participants: Ninety-seven women with newly diagnosed stage I-III breast cancer who were scheduled to receive at least four 3-week cycles of chemotherapy. Measurement and Results: Objective sleep parameters were measured with an Actillume actigraph (Ambulatory Monitoring Inc.). Subjective sleep quality was assessed with the Pittsburgh Sleep Quality Index (PSQI). Fatigue was assessed with the Multidimensional Fatigue Symptom Inventory-Short Form (MFSI-SF). Fatigue became worse during both cycles of chemotherapy (P-values < 0.01). Subjective sleep quality was poor at baseline and remained unchanged throughout treatment. Objective nighttime and daytime total sleep time increased compared to baseline during the treatment administration week of both cycles; daytime total wake time decreased during the treatment week of both cycles and during the last 2 week of cycle 4. Mixed model results revealed that fatigue was positively associated with total PSQI scores and with objective measures of total nap time, and negatively associated with total wake time during the day (all P-values < 0.01). Conclusion: Fatigue was significantly associated with subjective reports of poor sleep and objective measures of daytime sleepiness, but not with nocturnal sleep as measured with actigraphy. This relationship between fatigue and sleep warrants further studies to explore their possible common underlying etiology. Citation: Liu L; Rissling M; Natarajan L; Fiorentino L; Mills PJ; Dimsdale JE; Sadler GR; Parker BA; Ancoli-Israel S. The longitudinal relationship between fatigue and sleep in breast cancer patients undergoing chemotherapy. SLEEP 2012;35(2):237-245. PMID:22294814

  4. Accelerometer thresholds: Accounting for body mass reduces discrepancies between measures of physical activity for individuals with overweight and obesity.

    PubMed

    Raiber, Lilian; Christensen, Rebecca A G; Jamnik, Veronica K; Kuk, Jennifer L

    2017-01-01

    The objective of this study was to explore whether accelerometer thresholds that are adjusted to account for differences in body mass influence discrepancies between self-report and accelerometer-measured physical activity (PA) volume for individuals with overweight and obesity. We analyzed 6164 adults from the National Health and Nutrition Examination Survey between 2003-2006. Established accelerometer thresholds were adjusted to account for differences in body mass to produce a similar energy expenditure (EE) rate as individuals with normal weight. Moderate-, vigorous-, and moderate- to vigorous-intensity PA (MVPA) durations were measured using established and adjusted accelerometer thresholds and compared with self-report. Durations of self-report were longer than accelerometer-measured MVPA using established thresholds (normal weight: 57.8 ± 2.4 vs 9.0 ± 0.5 min/day, overweight: 56.1 ± 2.7 vs 7.4 ± 0.5 min/day, and obesity: 46.5 ± 2.2 vs 3.7 ± 0.3 min/day). Durations of subjective and objective PA were negatively associated with body mass index (BMI) (P < 0.05). Using adjusted thresholds increased MVPA durations, and reduced discrepancies between accelerometer and self-report measures for overweight and obese groups by 6.0 ± 0.3 min/day and 17.7 ± 0.8 min/day, respectively (P < 0.05). Using accelerometer thresholds that represent equal EE rates across BMI categories reduced the discrepancies between durations of subjective and objective PA for overweight and obese groups. However, accelerometer-measured PA generally remained shorter than durations of self-report within all BMI categories. Further research may be necessary to improve analytical approaches when using objective measures of PA for individuals with overweight or obesity.

  5. A Comparison of Measures of Boldness and Their Relationships to Survival in Young Fish

    PubMed Central

    White, James R.; Meekan, Mark G.; McCormick, Mark I.; Ferrari, Maud C. O.

    2013-01-01

    Boldness is the propensity of an animal to engage in risky behavior. Many variations of novel-object or novel-environment tests have been used to quantify the boldness of animals, although the relationship between test outcomes has rarely been investigated. Furthermore, the relationship of outcomes to any ecological aspect of fitness is generally assumed, rather than measured directly. Our study is the first to compare how the outcomes of the same test of boldness differ among observers and how different tests of boldness relate to the survival of individuals in the field. Newly-metamorphosed lemon damselfish, Pomacentrus moluccensis, were placed onto replicate patches of natural habitat. Individual behavior was quantified using four tests (composed of a total of 12 different measures of behavior): latency to enter a novel environment, activity in a novel environment, and reactions to threatening and benign novel objects. After behavior was quantified, survival was monitored for two days during which time fish were exposed to natural predators. Variation among observers was low for most of the 12 measures, except distance moved and the threat test (reaction to probe thrust), which displayed unacceptable amounts of inter-observer variation. Overall, the results of the behavioral tests suggested that novel environment and novel object tests quantified similar behaviors, yet these behavioral measures were not interchangeable. Multiple measures of behavior within the context of novel environment or object tests were the most robust way to assess boldness and these measures have a complex relationship with survivorship of young fish in the field. Body size and distance ventured from shelter were the only variables that had a direct and positive relationship with survival. PMID:23874804

  6. A comparison of measures of boldness and their relationships to survival in young fish.

    PubMed

    White, James R; Meekan, Mark G; McCormick, Mark I; Ferrari, Maud C O

    2013-01-01

    Boldness is the propensity of an animal to engage in risky behavior. Many variations of novel-object or novel-environment tests have been used to quantify the boldness of animals, although the relationship between test outcomes has rarely been investigated. Furthermore, the relationship of outcomes to any ecological aspect of fitness is generally assumed, rather than measured directly. Our study is the first to compare how the outcomes of the same test of boldness differ among observers and how different tests of boldness relate to the survival of individuals in the field. Newly-metamorphosed lemon damselfish, Pomacentrus moluccensis, were placed onto replicate patches of natural habitat. Individual behavior was quantified using four tests (composed of a total of 12 different measures of behavior): latency to enter a novel environment, activity in a novel environment, and reactions to threatening and benign novel objects. After behavior was quantified, survival was monitored for two days during which time fish were exposed to natural predators. Variation among observers was low for most of the 12 measures, except distance moved and the threat test (reaction to probe thrust), which displayed unacceptable amounts of inter-observer variation. Overall, the results of the behavioral tests suggested that novel environment and novel object tests quantified similar behaviors, yet these behavioral measures were not interchangeable. Multiple measures of behavior within the context of novel environment or object tests were the most robust way to assess boldness and these measures have a complex relationship with survivorship of young fish in the field. Body size and distance ventured from shelter were the only variables that had a direct and positive relationship with survival.

  7. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    PubMed

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  8. A Comparison of Subjective and Objective Job Demands and Fit with Personal Resources as Predictors of Retirement Timing in a National U.S. Sample.

    PubMed

    Sonnega, Amanda; Helppie-McFall, Brooke; Hudomiet, Peter; Willis, Robert J; Fisher, Gwenith G

    2017-12-19

    Population aging and attendant pressures on public budgets have spurred considerable interest in understanding factors that influence retirement timing. A range of sociodemographic and economic characteristics predict both earlier and later retirement. Less is known about the role of job characteristics on the work choices of older workers. Researchers are increasingly using the subjective ratings of job characteristics available in the Health and Retirement Study in conjunction with more objective measures of job characteristics from the Occupational Information Network (O*NET) database. Employing a theoretically-informed model of job demands-personal resources fit, we constructed mismatch measures between resources and job demands (both subjectively and objectively assessed) in physical, emotional, and cognitive domains. When we matched comparable measures across the two data sources in the domains of physical, emotional, and cognitive job demands, we found that both sources of information held predictive power in relation to retirement timing. Physical and emotional but not cognitive mismatch were associated with earlier retirement. We discuss theoretical and practical implications of these findings and directions for future research.

  9. A subjective study and an objective metric to quantify the granularity level of textures

    NASA Astrophysics Data System (ADS)

    Subedar, Mahesh M.; Karam, Lina J.

    2015-03-01

    Texture granularity is an important visual characteristic that is useful in a variety of applications, including analysis, recognition, and compression, to name a few. A texture granularity measure can be used to quantify the perceived level of texture granularity. The granularity level of the textures is influenced by the size of the texture primitives. A primitive is defined as the smallest recognizable repetitive object in the texture. If the texture has large primitives then the perceived granularity level tends to be lower as compared to a texture with smaller primitives. In this work we are presenting a texture granularity database referred as GranTEX which consists of 30 textures with varying levels of primitive sizes and granularity levels. The GranTEX database consists of both natural and man-made textures. A subjective study is conducted to measure the perceived granularity level of textures present in the GranTEX database. An objective metric that automatically measures the perceived granularity level of textures is also presented as part of this work. It is shown that the proposed granularity metric correlates well with the subjective granularity scores.

  10. Change Detection Algorithms for Surveillance in Visual IoT: A Comparative Study

    NASA Astrophysics Data System (ADS)

    Akram, Beenish Ayesha; Zafar, Amna; Akbar, Ali Hammad; Wajid, Bilal; Chaudhry, Shafique Ahmad

    2018-01-01

    The VIoT (Visual Internet of Things) connects virtual information world with real world objects using sensors and pervasive computing. For video surveillance in VIoT, ChD (Change Detection) is a critical component. ChD algorithms identify regions of change in multiple images of the same scene recorded at different time intervals for video surveillance. This paper presents performance comparison of histogram thresholding and classification ChD algorithms using quantitative measures for video surveillance in VIoT based on salient features of datasets. The thresholding algorithms Otsu, Kapur, Rosin and classification methods k-means, EM (Expectation Maximization) were simulated in MATLAB using diverse datasets. For performance evaluation, the quantitative measures used include OSR (Overall Success Rate), YC (Yule's Coefficient) and JC (Jaccard's Coefficient), execution time and memory consumption. Experimental results showed that Kapur's algorithm performed better for both indoor and outdoor environments with illumination changes, shadowing and medium to fast moving objects. However, it reflected degraded performance for small object size with minor changes. Otsu algorithm showed better results for indoor environments with slow to medium changes and nomadic object mobility. k-means showed good results in indoor environment with small object size producing slow change, no shadowing and scarce illumination changes.

  11. Healthy Volunteer 2020: Comparing Peace Corps Volunteers' health metrics with Healthy People 2020 national objectives.

    PubMed

    Henderson, Susan J; Newman, Jeannette; Ferguson, Rennie W; Jung, Paul

    2016-12-01

    Healthy People 2020 (HP2020) provides a set of quantifiable objectives for improving the health and well-being of Americans. This study examines Peace Corps Volunteers' health metrics in comparison with the Leading Health Indicators (LHIs) in order to set baseline measures for Volunteers' health care and align our measurements with Healthy People 2020 standards. Health data from multiple internal Peace Corps datasets were compared with relevant LHIs and analyzed using descriptive statistics. Seventeen (65%) of the 26 LHIs were relevant to Peace Corps Volunteers. Of these, Volunteers' health measures met or were more favorable than the goals of 13 (76%) of the LHIs. There were no data available for 4 (24%) of the LHIs. The entire Volunteer population has full access to primary care, oral health, and reproductive health services. No suicides or homicides were reported among Volunteers during the analyzed time period. Utilizing the LHIs, we have identified high-priority public health issues relevant for the Peace Corps Volunteer population. We discuss the need for quality data to measure and monitor Volunteers' health progress and outcomes over time, and also to standardize our measurements with Healthy People 2020 benchmarks. This framework may foster greater collaboration to engage in health promotion and disease prevention activities driven by evidence-based information, which may, in turn, encourage healthy behavior among Volunteers.

  12. Subjective perception of sleep benefit in Parkinson's disease: Valid or irrelevant?

    PubMed

    Lee, Will; Evans, Andrew; Williams, David R

    2017-09-01

    The phenomenon of sleep benefit (SB) in Parkinson's disease (PD), whereby waking motor function is improved despite no dopaminergic treatment overnight, is controversial. Previous studies suggested a significant discrepancy between subjective functional and objective motor improvement. The aim of this study was to determine how well subjective reporting of SB correlates with objective measures and if true motor improvement can be predicted by a standardized questionnaire. Ninety-two patients with PD participated. A structured questionnaire was developed to assess subjective SB. Quantitative motor assessment was performed using a validated smartphone application. Objective motor SB was considered to be present when the waking motor function was similar or superior to the daytime on-state. Twenty (22%) patients showed objective motor improvement on waking compared to end-of-dose. Most patients (77%) reported subjective SB without corresponding objective motor benefit. Our structured questionnaire could not predict Motor SB. The ability to delay morning medications and a perception of indifference or paradoxical worsening following the morning levodopa dose may suggest Motor SB. Most patients experience subjective SB with no measureable motor improvement. This perceived benefit could be related to non-motor improvement that is distinctly different to objective motor benefit. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. In multiple situational light settings, visual observation for skin colour assessment is comparable with colorimeter measurement.

    PubMed

    Wright, C Y; Wilkes, M; du Plessis, J L; Reeder, A I; Albers, P N

    2016-08-01

    Finding inexpensive and reliable techniques for assessing skin colour is important, given that it is related to several adverse human health outcomes. Visual observation is considered a subjective approach assessment and, even when made by trained assessor, concern has been raised about the need for controlled lighting in the study venue. The aim of this study is to determine whether visual skin colour assessments correlate with objective skin colour measurements in study venues with different lighting types and configurations. Two trained investigators, with confirmed visual acuity, visually classified the inner, upper arm skin colour of 556 adults using Munsell(®) colour classifications converted to Individual Typology Angle (°ITA) values based on published data. Skin colour at the same anatomic site was also measured using a colorimeter. Each participant was assessed in one of 10 different buildings, each with a different study day. Munsell(®) -derived °ITA values were compared to colorimeter °ITA values for the full sample and by building/day. We found a strong positive, monotonic correlation between Munsell(®) derived °ITA values and colorimeter °ITA values for all participants (Spearman ρ = 0.8585, P < 0.001). Similar relationships were found when Munsell(®) and colorimeter °ITA values were compared for participants assessed in the same building for all 10 buildings (Spearman ρ values ranged from 0.797 to 0.934, all correlations were statistically significant at P < 0.001). It is possible to visually assess individual skin colour in multiple situational lighting settings and retrieve results that are comparable with objective measurements of skin colour. This was true for individuals of varying population groups and skin pigmentation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Unmixing techniques for better segmentation of urban zones, roads, and open pit mines

    NASA Astrophysics Data System (ADS)

    Nikolov, Hristo; Borisova, Denitsa; Petkov, Doyno

    2010-10-01

    In this paper the linear unmixing method has been applied in classification of manmade objects, namely urbanized zones, roads etc. The idea is to exploit to larger extent the possibilities offered by multispectral imagers having mid spatial resolution in this case TM/ETM+ instruments. In this research unmixing is used to find consistent regression dependencies between multispectral data and those gathered in-situ and airborne-based sensors. The correct identification of the mixed pixels is key element for the subsequent segmentation forming the shape of the artificial feature is determined much more reliable. This especially holds true for objects with relatively narrow structure for example two-lane roads for which the spatial resolution is larger that the object itself. We have combined ground spectrometry of asphalt, Landsat images of RoI, and in-situ measured asphalt in order to determine the narrow roads. The reflectance of paving stones made from granite is highest compared to another ones which is true for open and stone pits. The potential for mapping is not limited to the mid-spatial Landsat data, but also may be used if the data has higher spatial resolution (as fine as 0.5 m). In this research the spectral and directional reflection properties of asphalt and concrete surfaces compared to those of paving stone made from different rocks have been measured. The in-situ measurements, which plays key role have been obtained using the Thematically Oriented Multichannel Spectrometer (TOMS) - designed in STIL-BAS.

  15. Persistent Fatigue in Hematopoietic Stem Cell Transplantation Survivors

    PubMed Central

    Hacker, Eileen Danaher; Fink, Anne M.; Peters, Tara; Park, Chang; Fantuzzi, Giamila; Rondelli, Damiano

    2016-01-01

    Background Fatigue is highly prevalent following hematopoietic stem cell transplantation (HCT). It has been described as intense and may last for years following treatment. Objective to compare fatigue, physical activity, sleep, emotional distress, cognitive function, and biological measures in HCT survivors with persistent fatigue (n = 25) to age- and gender-matched healthy controls with occasional tiredness (n = 25). Methods Data were collected using: (a) objective, real-time assessments of physical activity and sleep over 7 days; (b) patient-reported fatigue assessments; (c) computerized objective testing of cognitive functioning; and (d) biological measures. Differences between groups were examined using MANOVA. Results HCT survivors reported increased physical (p < .001), mental (p <.001), and overall fatigue (p < .001) as well as increased anxiety (p < .05) and depression (p < .01) compared to healthy controls. Red blood cell (RBC) levels were significantly lower in HCT survivors (p < .001). RBC levels for both groups, however, were in the normal range. TNF-α (p < .001) and IL-6 (p < .05) were significantly higher in HCT survivors. Conclusions Persistent fatigue in HCT survivors compared to healthy controls with occasional tiredness is accompanied by increased anxiety and depression along with decreased RBCs. Elevated TNF-α and IL-6 may be important biomarkers. Implications for Practice This study provides preliminary support for the conceptualization of fatigue as existing on a continuum, with tiredness anchoring one end and exhaustion the other. Persistent fatigue experienced by HCT survivors is more severe than the occasional tiredness of everyday life. PMID:27333126

  16. Pixel-based flood mapping from SAR imagery: a comparison of approaches

    NASA Astrophysics Data System (ADS)

    Landuyt, Lisa; Van Wesemael, Alexandra; Van Coillie, Frieke M. B.; Verhoest, Niko E. C.

    2017-04-01

    Due to their all-weather, day and night capabilities, SAR sensors have been shown to be particularly suitable for flood mapping applications. Thus, they can provide spatially-distributed flood extent data which are valuable for calibrating, validating and updating flood inundation models. These models are an invaluable tool for water managers, to take appropriate measures in times of high water levels. Image analysis approaches to delineate flood extent on SAR imagery are numerous. They can be classified into two categories, i.e. pixel-based and object-based approaches. Pixel-based approaches, e.g. thresholding, are abundant and in general computationally inexpensive. However, large discrepancies between these techniques exist and often subjective user intervention is needed. Object-based approaches require more processing but allow for the integration of additional object characteristics, like contextual information and object geometry, and thus have significant potential to provide an improved classification result. As means of benchmark, a selection of pixel-based techniques is applied on a ERS-2 SAR image of the 2006 flood event of River Dee, United Kingdom. This selection comprises Otsu thresholding, Kittler & Illingworth thresholding, the Fine To Coarse segmentation algorithm and active contour modelling. The different classification results are evaluated and compared by means of several accuracy measures, including binary performance measures.

  17. Reconstruction of vibroacoustic responses of a highly nonspherical structure using Helmholtz equation least-squares method.

    PubMed

    Lu, Huancai; Wu, Sean F

    2009-03-01

    The vibroacoustic responses of a highly nonspherical vibrating object are reconstructed using Helmholtz equation least-squares (HELS) method. The objectives of this study are to examine the accuracy of reconstruction and the impacts of various parameters involved in reconstruction using HELS. The test object is a simply supported and baffled thin plate. The reason for selecting this object is that it represents a class of structures that cannot be exactly described by the spherical Hankel functions and spherical harmonics, which are taken as the basis functions in the HELS formulation, yet the analytic solutions to vibroacoustic responses of a baffled plate are readily available so the accuracy of reconstruction can be checked accurately. The input field acoustic pressures for reconstruction are generated by the Rayleigh integral. The reconstructed normal surface velocities are validated against the benchmark values, and the out-of-plane vibration patterns at several natural frequencies are compared with the natural modes of a simply supported plate. The impacts of various parameters such as number of measurement points, measurement distance, location of the origin of the coordinate system, microphone spacing, and ratio of measurement aperture size to the area of source surface of reconstruction on the resultant accuracy of reconstruction are examined.

  18. Objective evaluation of slanted edge charts

    NASA Astrophysics Data System (ADS)

    Hornung, Harvey (.

    2015-01-01

    Camera objective characterization methodologies are widely used in the digital camera industry. Most objective characterization systems rely on a chart with specific patterns, a software algorithm measures a degradation or difference between the captured image and the chart itself. The Spatial Frequency Response (SFR) method, which is part of the ISO 122331 standard, is now very commonly used in the imaging industry, it is a very convenient way to measure a camera Modulation transfer function (MTF). The SFR algorithm can measure frequencies beyond the Nyquist frequency thanks to super-resolution, so it does provide useful information on aliasing and can provide modulation for frequencies between half Nyquist and Nyquist on all color channels of a color sensor with a Bayer pattern. The measurement process relies on a chart that is simple to manufacture: a straight transition from a bright reflectance to a dark one (black and white for instance), while a sine chart requires handling precisely shades of gray which can also create all sort of issues with printers that rely on half-toning. However, no technology can create a perfect edge, so it is important to assess the quality of the chart and understand how it affects the accuracy of the measurement. In this article, I describe a protocol to characterize the MTF of a slanted edge chart, using a high-resolution flatbed scanner. The main idea is to use the RAW output of the scanner as a high-resolution micro-densitometer, since the signal is linear it is suitable to measure the chart MTF using the SFR algorithm. The scanner needs to be calibrated in sharpness: the scanner MTF is measured with a calibrated sine chart and inverted to compensate for the modulation loss from the scanner. Then the true chart MTF is computed. This article compares measured MTF from commercial charts and charts printed on printers, and also compares how of the contrast of the edge (using different shades of gray) can affect the chart MTF, then concludes on what distance range and camera resolution the chart can reliably measure the camera MTF.

  19. BENTHIC MICROBIAL RESPIRATION IN APPALACHIAN MOUNTAIN, PIEDMONT, AND COASTAL PLAINS, STREAMS OF THE EASTERN USA

    EPA Science Inventory

    Our study had two objectives. First, in order to quantify the potential underestimation of community respiration caused by the exclusion of anaerobic processes, we compared benthic microbial respiration measured as 02 consumption with estimated based on DHA. Second, our previous ...

  20. Hologram repositioning by an interferometric technique.

    PubMed

    Soares, O D

    1979-11-15

    An interferometric technique for hologram repositioning is described where the hologram is compared with the interference pattern of the reference and object waves. Analytical expressions to evaluate the accuracy of the repositioning are presented for the method. Two applications of the method in metrology for micromovement measurements are proposed.

  1. 7 CFR 3052.210 - Subrecipient and vendor determinations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT... performance measured against whether the objectives of the Federal program are met; (3) Has responsibility for... requirements; and (5) Uses the Federal funds to carry out a program of the organization as compared to...

  2. Parental Perceptions of Their Adolescent's Weight Status: The ECHO Study

    ERIC Educational Resources Information Center

    Hearst, Mary O.; Sherwood, Nancy E.; Klein, Elizabeth G.; Pasch, Keryn E.; Lytle, Leslie A.

    2011-01-01

    Objectives: To assess the correlates of parental classification of adolescent weight status. Methods: Measured adolescent weight status was compared to parent self-report perception data (n 374 dyads) using multivariate analyses with interactions to identify characteristics associated with inaccurate parent classification of adolescent weight…

  3. Wants, Needs and Satisfaction: A Comparative Study in Thailand and Bangladesh

    ERIC Educational Resources Information Center

    Camfield, Laura; Guillen-Royo, Monica

    2010-01-01

    Within international development greater income is assumed to lead to greater need fulfilment, which increases subjective wellbeing. The Wellbeing in Developing Countries ESRC Research Group's dataset provides an opportunity to test these relationships using measures of income, expenditure, perceived and "objective" need satisfaction and…

  4. Functional dissociation between action and perception of object shape in developmental visual object agnosia.

    PubMed

    Freud, Erez; Ganel, Tzvi; Avidan, Galia; Gilaie-Dotan, Sharon

    2016-03-01

    According to the two visual systems model, the cortical visual system is segregated into a ventral pathway mediating object recognition, and a dorsal pathway mediating visuomotor control. In the present study we examined whether the visual control of action could develop normally even when visual perceptual abilities are compromised from early childhood onward. Using his fingers, LG, an individual with a rare developmental visual object agnosia, manually estimated (perceptual condition) the width of blocks that varied in width and length (but not in overall size), or simply picked them up across their width (grasping condition). LG's perceptual sensitivity to target width was profoundly impaired in the manual estimation task compared to matched controls. In contrast, the sensitivity to object shape during grasping, as measured by maximum grip aperture (MGA), the time to reach the MGA, the reaction time and the total movement time were all normal in LG. Further analysis, however, revealed that LG's sensitivity to object shape during grasping emerged at a later time stage during the movement compared to controls. Taken together, these results demonstrate a dissociation between action and perception of object shape, and also point to a distinction between different stages of the grasping movement, namely planning versus online control. Moreover, the present study implies that visuomotor abilities can develop normally even when perceptual abilities developed in a profoundly impaired fashion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Interactive Multiple Object Tracking (iMOT)

    PubMed Central

    Thornton, Ian M.; Bülthoff, Heinrich H.; Horowitz, Todd S.; Rynning, Aksel; Lee, Seong-Whan

    2014-01-01

    We introduce a new task for exploring the relationship between action and attention. In this interactive multiple object tracking (iMOT) task, implemented as an iPad app, participants were presented with a display of multiple, visually identical disks which moved independently. The task was to prevent any collisions during a fixed duration. Participants could perturb object trajectories via the touchscreen. In Experiment 1, we used a staircase procedure to measure the ability to control moving objects. Object speed was set to 1°/s. On average participants could control 8.4 items without collision. Individual control strategies were quite variable, but did not predict overall performance. In Experiment 2, we compared iMOT with standard MOT performance using identical displays. Object speed was set to 2°/s. Participants could reliably control more objects (M = 6.6) than they could track (M = 4.0), but performance in the two tasks was positively correlated. In Experiment 3, we used a dual-task design. Compared to single-task baseline, iMOT performance decreased and MOT performance increased when the two tasks had to be completed together. Overall, these findings suggest: 1) There is a clear limit to the number of items that can be simultaneously controlled, for a given speed and display density; 2) participants can control more items than they can track; 3) task-relevant action appears not to disrupt MOT performance in the current experimental context. PMID:24498288

  6. Bonding and expressed emotion: two interlinked concepts?

    PubMed

    Duclos, Jeanne; Maria, Anne-Solène; Dorard, Géraldine; Curt, Florence; Apfel, Alexandre; Vibert, Sarah; Rein, Zoé; Perdereau, Fabienne; Godart, Nathalie

    2013-01-01

    Bonding and expressed emotion (EE) are two concepts modeling family relationships. Two studies, with contradictory results, have explored whether these concepts and their corresponding instruments [the Parental Bonding Instrument (PBI) and the Camberwell Family Interview] do indeed measure the same aspects of family relationships. Our first objective was to compare the adolescents' perceptions of family relationships using the PBI, and the parental viewpoint using the Five-Minute Speech Sample (FMSS-EE). Secondly, we compared the PBI scores and EE levels of the parents. Sixty adolescent girls with anorexia nervosa completed the PBI. The FMSS and a modified version of the PBI were administered to parents separately. No significant link was identified between adolescent PBI scores and parental EE levels. However, a link between maternal 'modified' PBI scores and maternal EE was observed: when mothers registered a high Final EE, they were more likely to deny their daughter's psychological autonomy compared to mothers with lower EE. Our empirical results do not support the hypothesis of an overlap between the two concepts. Indeed bonding and EE measure the same object, i.e. the quality of family relationships, but time scales differ and so do the perspectives (patient vs. parental viewpoint). Copyright © 2012 S. Karger AG, Basel.

  7. An Objective Verification of the North American Mesoscale Model for Kennedy Space Center and Cape Canaveral Air Force Station

    NASA Technical Reports Server (NTRS)

    Bauman, William H., III

    2010-01-01

    The 45th Weather Squadron (45 WS) Launch Weather Officers use the 12-km resolution North American Mesoscale (NAM) model (MesoNAM) text and graphical product forecasts extensively to support launch weather operations. However, the actual performance of the model at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) has not been measured objectively. In order to have tangible evidence of model performance, the 45 WS tasked the Applied Meteorology Unit to conduct a detailed statistical analysis of model output compared to observed values. The model products are provided to the 45 WS by ACTA, Inc. and include hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The objective analysis compared the MesoNAM forecast winds, temperature and dew point, as well as the changes in these parameters over time, to the observed values from the sensors in the KSC/CCAFS wind tower network. Objective statistics will give the forecasters knowledge of the model's strength and weaknesses, which will result in improved forecasts for operations.

  8. Comparative analysis of autofocus functions in digital in-line phase-shifting holography.

    PubMed

    Fonseca, Elsa S R; Fiadeiro, Paulo T; Pereira, Manuela; Pinheiro, António

    2016-09-20

    Numerical reconstruction of digital holograms relies on a precise knowledge of the original object position. However, there are a number of relevant applications where this parameter is not known in advance and an efficient autofocusing method is required. This paper addresses the problem of finding optimal focusing methods for use in reconstruction of digital holograms of macroscopic amplitude and phase objects, using digital in-line phase-shifting holography in transmission mode. Fifteen autofocus measures, including spatial-, spectral-, and sparsity-based methods, were evaluated for both synthetic and experimental holograms. The Fresnel transform and the angular spectrum reconstruction methods were compared. Evaluation criteria included unimodality, accuracy, resolution, and computational cost. Autofocusing under angular spectrum propagation tends to perform better with respect to accuracy and unimodality criteria. Phase objects are, generally, more difficult to focus than amplitude objects. The normalized variance, the standard correlation, and the Tenenbaum gradient are the most reliable spatial-based metrics, combining computational efficiency with good accuracy and resolution. A good trade-off between focus performance and computational cost was found for the Fresnelet sparsity method.

  9. A phase-stepped point diffraction interferometer using liquid crystals

    NASA Technical Reports Server (NTRS)

    Mercer, Carolyn R.; Creath, Katherine; Rashidnia, Nasser

    1995-01-01

    A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

  10. Measuring skin necrosis in a randomised controlled feasibility trial of heat preconditioning on wound healing after reconstructive breast surgery: study protocol and statistical analysis plan for the PREHEAT trial.

    PubMed

    Cro, Suzie; Mehta, Saahil; Farhadi, Jian; Coomber, Billie; Cornelius, Victoria

    2018-01-01

    Essential strategies are needed to help reduce the number of post-operative complications and associated costs for breast cancer patients undergoing reconstructive breast surgery. Evidence suggests that local heat preconditioning could help improve the provision of this procedure by reducing skin necrosis. Before testing the effectiveness of heat preconditioning in a definitive randomised controlled trial (RCT), we must first establish the best way to measure skin necrosis and estimate the event rate using this definition. PREHEAT is a single-blind randomised controlled feasibility trial comparing local heat preconditioning, using a hot water bottle, against standard care on skin necrosis among breast cancer patients undergoing reconstructive breast surgery. The primary objective of this study is to determine the best way to measure skin necrosis and to estimate the event rate using this definition in each trial arm. Secondary feasibility objectives include estimating recruitment and 30 day follow-up retention rates, levels of compliance with the heating protocol, length of stay in hospital and the rates of surgical versus conservative management of skin necrosis. The information from these objectives will inform the design of a larger definitive effectiveness and cost-effectiveness RCT. This article describes the PREHEAT trial protocol and detailed statistical analysis plan, which includes the pre-specified criteria and process for establishing the best way to measure necrosis. This study will provide the evidence needed to establish the best way to measure skin necrosis, to use as the primary outcome in a future RCT to definitively test the effectiveness of local heat preconditioning. The pre-specified statistical analysis plan, developed prior to unblinded data extraction, sets out the analysis strategy and a comparative framework to support a committee evaluation of skin necrosis measurements. It will increase the transparency of the data analysis for the PREHEAT trial. ISRCTN ISRCTN15744669. Registered 25 February 2015.

  11. Optical extensometer

    DOEpatents

    Walker, Ray A.; Reich, Fred R.; Russell, James T.

    1978-01-01

    An optical extensometer is described using sequentially pulsed light beams for measuring the dimensions of objects by detecting two opposite edges of the object without contacting the object. The light beams may be of different distinguishable light characteristics, such as polarization or wave length, and are time modulated in an alternating manner at a reference frequency. The light characteristics are of substantially the same total light energy and are distributed symmetrically. In the preferred embodiment two light beam segments of one characteristic are on opposite sides of a middle segment of another characteristic. As a result, when the beam segments are scanned sequentially across two opposite edges of the object, they produce a readout signal at the output of a photoelectric detector that is compared with the reference signal by a phase comparator to produce a measurement signal with a binary level transition when the light beams cross an edge. The light beams may be of different cross sectional geometries, including two superimposed and concentric circular beam cross sections of different diameter, or two rectangular cross sections which intersect with each other substantially perpendicular so only their central portions are superimposed. Alternately, a row of three light beams can be used including two outer beams on opposite sides and separate from a middle beam. The three beams may all be of the same light characteristic. However it is preferable that the middle beam be of a different characteristic but of the same total energy as the two outer beams.

  12. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    PubMed

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P < 0.001). The 3DWM device yielded correlations of ρ = 0.990, 0.987, 0.996 with P < 0.001 for length, width, and area when compared to manual measurements. The 3DWM device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  13. Safe sleep practices and sudden infant death syndrome risk reduction: NICU and well-baby nursery graduates.

    PubMed

    Fowler, Aja J; Evans, Patricia W; Etchegaray, Jason M; Ottenbacher, Allison; Arnold, Cody

    2013-11-01

    Our primary objective was to compare parents of infants cared for in newborn intensive care units (NICUs) and infants cared for in well-baby ("general") nurseries with regard to knowledge and practice of safe sleep practices/sudden infant death syndrome risk reduction measures and guidelines. Our secondary objective was to obtain qualitative data regarding reasons for noncompliance in both populations. Sixty participants (30 from each population) completed our survey measuring safe sleep knowledge and practice. Parents of NICU infants reported using 2 safe sleep practices-(a) always placing baby in crib to sleep and (b) always placing baby on back to sleep-significantly more frequently than parents of well infants. Additional findings and implications for future studies are discussed.

  14. Differences in self-reported physical limitation among older women and men in Ismailia, Egypt.

    PubMed

    Khadr, Zeinab; Yount, Kathryn

    2012-09-01

    This study explores the reasons for gender differences in self-reported physical limitation among older adults in Ismailia, Egypt. 435 women and 448 men, 50 years and older in Ismailia, Egypt, participated in a social survey and tests of physical performance. Ordered logit models were estimated to compare unadjusted gender differences in reported disability with these differences adjusted sequentially for (a) age and objective measures of physical performance, (b) self-reported morbidities and health care use, and (c) social and economic attributes. Compared with men, women more often reported higher levels of limitation in activities of daily living (ADLs), upper-extremity range of motion (ROM), and lower-extremity gross mobility (GM). Adjusting for age and objective measures of physical performance, women and men had similar odds of self-reporting difficulty with ADLs. With sequential adjustments for the remaining variables, women maintained significantly higher odds of self-reported difficulty with upper-extremity ROM and lower-extremity GM. Cross-culturally, gender differences in self-reported disability may arise from objective and subjective perceptions of disability. Collectively, these results and those from prior studies in Bangladesh and the United States suggest that gender gaps in self-reported physical limitation may be associated with the degree of gender equality in society.

  15. Properties of resonant trans-Neptunian objects based on Herschel Space Observatory data

    NASA Astrophysics Data System (ADS)

    Farkas Anikó, Takácsné; Kiss, Csaba; Mueller, Thomas G.; Mommert, Michael; Vilenius, Esa

    2016-10-01

    The goal of our work is to characterise the physical characteristics of resonant, detached and scattered disk objects in the trans-Neptunian region, observed in the framework of the "TNOs are Cool!" Herschel Open Time Key Program. Based on thermal emission measurements with the Herschel/PACS and Spitzer/MIPS instruments we were able to determine size, albedo, and surface thermal properties for 23 objects using radiometric modelling techniques. This is the first analysis in which the physical properties of objects in the outer resonances are determined for a larger sample. In addition to the results for individual objects, we have compared these characteristic with the bulk properties of other populations of the trans-Neptunian region. The newly analysed objects show e.g. a large variety of beaming factors, indicating diverse surfaces, and in general they follow the albedo-colour clustering identified earlier for Kuiper belt objects and Centaurs, further strengthening the evidence for a compositional discontinuity in the young solar system.

  16. Automated volumetric evaluation of stereoscopic disc photography

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S

    2010-01-01

    PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996

  17. Measurement of wall thickness alone does not accurately assess the presence of left ventricular hypertrophy.

    PubMed

    Leibowitz, David; Planer, David; Ben-Ibgi, Fanny; Rott, David; Weiss, A Teddy; Bursztyn, Michael

    2007-02-01

    Clinical echocardiographic assessment of left ventricular hypertrophy (LVH) is generally performed by measuring wall thickness alone (WT). The objective of this study was to compare the assessment of LVH using the measurement of WT to that using indexed LV mass. Hypertensive patients underwent echocardiography with the measurement of LV WT and LV mass. For each patient, the presence of LVH was assessed by both methods with WT compared to the gold standard of LV mass index. In all, 92 patients (51M/41F) were entered, and in only 55 patients (60%) were the two methods concordant. There was a tendency for WT to underestimate LVH in females (sensitivity 37%, specificity 79%) and overestimate LVH in males (sensitivity 88%, specificity 56%). The measurement of WT alone overestimates LVH in males and underestimates LVH in females and should not be used as a surrogate marker for increased LV mass.

  18. An Exploratory Study of Autonomic Function Investigations in Hemophiliacs on Homoeopathy Medications Using Impedance Plethysmography

    PubMed Central

    Kundu, Tapas K.; Barde, Pradip B.; Jindal, Ghanshyam D.; Motiwala, Farooq F.

    2017-01-01

    Background. Status of autonomic homoeostasis in hemostasic disturbances due to hemophilia needs to be studied. Objectives. To compare autonomic nervous system markers measured by heart rate variability (HRV) and blood flow variability (BFV) in hemophiliacs and healthy age-matched control population using medical analyzer system. Design. Cross-sectional study. Settings. Motiwala Homoeopathy Medical College, and Hemophilia Clinics, Nashik. Subjects. Eighty subjects. Interventions. Nil. Outcome Measures. Autonomic function markers for HRV and BFV. Results. Among 80 subjects, BFV time domain measure, root mean square of successive NN (normal-to-normal) interval differences (RMSSD), was significantly higher among hemophiliacs than nonhemophiliacs. Frequency domain analysis parameter, low frequency for both HRV and BFV was significantly higher among hemophiliacs as compared with nonhemophiliacs. Conclusions. Hemophiliacs were shown to have higher autonomic activity as compared with healthy controls. Homoeopathic medicines used as an adjunct was associated with decrease in parasympathetic modulations. PMID:28719973

  19. Comparison of Two Methods for the Measurement of Medial and Lateral Metapodial Bones in Karagouniko Sheep (Ovis aries, L. 1758) and Hellenic Goat (Capra hircus, L. 1758)

    PubMed Central

    Pourlis, Aris; Chatzis, Theodoros; Katsoulos, Panagiotis

    2014-01-01

    The objective of this study was to compare the metapodial lengths of sheep and goats measured with a caliper with those measured using a 2-dimensional digital method. Complementarily, the lengths of medial and lateral metapodials in these species were compared. The limbs of 30 ewes and 30 goats were used. After preparation, the lateral and medial length of the metacarpals and metatarsals were measured twice with a caliper. Afterwards, each bone was scanned and the same lengths were digitally measured twice using commercial software. Data analysis revealed strong linear relationship between the two methods but the absolute relative deviation of the measurements with the caliper was significantly higher than those with the 2-dimensional method (P < 0.05). All lengths measured with the caliper were significantly higher compared to those measured with the 2-dimensional method (P < 0.05). In goats, the lateral length of both metacarpals and metatarsals was significantly higher than medial length (P < 0.05); in sheep the lateral length was significantly higher compared to the medial one only in metatarsal bones (P < 0.05). In conclusion, the 2-dimensional method is more accurate for the measurement of the metapodials' length than the caliper and there is asymmetry between the medial and lateral metapodials in these species. PMID:25530882

  20. Loneliness, social isolation and social relationships: what are we measuring? A novel framework for classifying and comparing tools

    PubMed Central

    Kanaan, Mona; Gilbody, Simon; Hanratty, Barbara

    2016-01-01

    Objectives We present a novel way of classifying and comparing measures of social relationships to help readers interpret the growing literature on loneliness and social isolation and to provide researchers with a starting point to guide their choice of measuring tool. Methods Measures of social relationships used in epidemiological studies were identified from two systematic reviews—one review on the association between social relationships and health and social care service use, and a second review on the association between social relationships and health. Questions from each measure were retrieved and tabulated to derive a classification of social relationship measures. Results We present a classification of measures according to two dimensions: (1) whether instruments cover structural or functional aspects of social relationships and (2) the degree of subjectivity asked of respondents. We explain how this classification can be used to clarify the remit of the many questionnaires used in the literature and to compare them. Conclusions Different dimensions of social relationships are likely to have different implications for health. Our classification of social relationship measures transcends disciplinary and conceptual boundaries, allowing researchers to compare tools that developed from different theoretical perspectives. Careful choice of measures is essential to further our understanding of the links between social relationships and health, to identify people in need of help and to design appropriate prevention and intervention strategies. PMID:27091822

  1. No Measured Effect of a Familiar Contextual Object on Color Constancy.

    PubMed

    Kanematsu, Erika; Brainard, David H

    2014-08-01

    Some familiar objects have a typical color, such as the yellow of a banana. The presence of such objects in a scene is a potential cue to the scene illumination, since the light reflected from them should on average be consistent with their typical surface reflectance. Although there are many studies on how the identity of an object affects how its color is perceived, little is known about whether the presence of a familiar object in a scene helps the visual system stabilize the color appearance of other objects with respect to changes in illumination. We used a successive color matching procedure in three experiments designed to address this question. Across the experiments we studied a total of 6 subjects (2 in Experiment 1, 3 in Experiment 2, and 4 in Experiment 3) with partial overlap of subjects between experiments. We compared measured color constancy across conditions in which a familiar object cue to the illuminant was available with conditions in which such a cue was not present. Overall, our results do not reveal a reliable improvement in color constancy with the addition of a familiar object to a scene. An analysis of the experimental power of our data suggests that if there is such an effect, it is small: less than approximately a change of 0.09 in a constancy index where an absence of constancy corresponds to an index value of 0 and perfect constancy corresponds to an index value of 1.

  2. No Measured Effect of a Familiar Contextual Object on Color Constancy

    PubMed Central

    Kanematsu, Erika; Brainard, David H.

    2013-01-01

    Some familiar objects have a typical color, such as the yellow of a banana. The presence of such objects in a scene is a potential cue to the scene illumination, since the light reflected from them should on average be consistent with their typical surface reflectance. Although there are many studies on how the identity of an object affects how its color is perceived, little is known about whether the presence of a familiar object in a scene helps the visual system stabilize the color appearance of other objects with respect to changes in illumination. We used a successive color matching procedure in three experiments designed to address this question. Across the experiments we studied a total of 6 subjects (2 in Experiment 1, 3 in Experiment 2, and 4 in Experiment 3) with partial overlap of subjects between experiments. We compared measured color constancy across conditions in which a familiar object cue to the illuminant was available with conditions in which such a cue was not present. Overall, our results do not reveal a reliable improvement in color constancy with the addition of a familiar object to a scene. An analysis of the experimental power of our data suggests that if there is such an effect, it is small: less than approximately a change of 0.09 in a constancy index where an absence of constancy corresponds to an index value of 0 and perfect constancy corresponds to an index value of 1. PMID:25313267

  3. Measurement equivalence: a glossary for comparative population health research.

    PubMed

    Morris, Katherine Ann

    2018-03-06

    Comparative population health studies are becoming more common and are advancing solutions to crucial public health problems, but decades-old measurement equivalence issues remain without a common vocabulary to identify and address the biases that contribute to non-equivalence. This glossary defines sources of measurement non-equivalence. While drawing examples from both within-country and between-country studies, this glossary also defines methods of harmonisation and elucidates the unique opportunities in addition to the unique challenges of particular harmonisation methods. Its primary objective is to enable population health researchers to more clearly articulate their measurement assumptions and the implications of their findings for policy. It is also intended to provide scholars and policymakers across multiple areas of inquiry with tools to evaluate comparative research and thus contribute to urgent debates on how to ameliorate growing health disparities within and between countries. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Locomotor activity, object exploration and space preference in children with autism and Down syndrome.

    PubMed

    Kawa, Rafał; Pisula, Ewa

    2010-01-01

    There have been ambiguous accounts of exploration in children with intellectual disabilities with respect to the course of that exploration, and in particular the relationship between the features of explored objects and exploratory behaviour. It is unclear whether reduced exploratory activity seen with object exploration but not with locomotor activity is autism-specific or if it is also present in children with other disabilities. The purpose of the present study was to compare preschool children with autism with their peers with Down syndrome and typical development in terms of locomotor activity and object exploration and to determine whether the complexity of explored objects affects the course of exploration activity in children with autism. In total there were 27 children in the study. The experimental room was divided into three zones equipped with experimental objects providing visual stimulation of varying levels of complexity. Our results indicate that children with autism and Down syndrome differ from children with typical development in terms of some measures of object exploration (i.e. looking at objects) and time spent in the zone with the most visually complex objects.

  5. Do Japanese American Women Really Have Fewer Hot Flashes than European Americans? The Hilo Women's Health Study

    PubMed Central

    Brown, Daniel E.; Sievert, Lynnette Leidy; Morrison, Lynn A.; Reza, Angela M.; Mills, Phoebe S.

    2009-01-01

    Objective Many studies have found a significantly lower frequency of reported hot flashes (HFs) in Japanese and Japanese American (JA) populations, leading to speculation about possible dietary, genetic, or cultural differences. These studies have relied upon subjective reports of HFs. Accordingly, the purpose of this study was to compare both reported and objective HFs measured by sternal and nuchal skin conductance among JA and European American (EA) women. Design Two surveys of hot flash frequencies were carried out among women of either EA or JA ethnicity, aged 45-55, living in Hilo, Hawaii, and not using exogenous hormones. The first was a postal questionnaire (N=325), the second was carried out during a clinical study of hot flashes (N=134). Women in the second group underwent 24-hour ambulatory and 3-hour laboratory monitoring for objective HFs measured through skin conductance at sternal and nuchal sites. Subjective HFs were recorded on the monitor, or in a diary. Results JAs were significantly less likely to report having had HFs in the previous two weeks compared with EAs (postal sample: JAs: 30.9%, EAs: 43.9%, χ2=6.9, p < .01; monitored sample: JAs: 26.1%, EAs: 46.6%, χ2=5.3, p < 0.05). JAs were also significantly less likely to report experiencing other symptoms (15 out of 30 in the postal sample; 6 of 30 in the monitored sample) than EAs. However, JAs did not significantly differ in likelihood of reporting subjective HFs during the 24-hour ambulatory period (JAs: 51.1%, EAs: 55.8%, χ2=0.3, ns), nor in percentage of individuals displaying one or more objective HFs as measured by the skin conductance monitor (JAs: 77.8%, EAs: 72.1%, χ2=0.5, ns). JAs also did not have a significantly fewer number of objective HFs (t=0.2, ns) nor of subjective HFs (t = 0.8, ns) during the monitoring period, and these results were unchanged when analyses controlled for menopausal status and BMI. Conclusions The common finding of fewer reported HFs in people of Japanese ancestry may be a consequence of reporting bias: JAs report fewer symptoms of many conditions compared to people from other ethnic groups. This is likely due to cultural conceptions of what is appropriate to report. PMID:19367185

  6. Simple Learned Weighted Sums of Inferior Temporal Neuronal Firing Rates Accurately Predict Human Core Object Recognition Performance

    PubMed Central

    Hong, Ha; Solomon, Ethan A.; DiCarlo, James J.

    2015-01-01

    To go beyond qualitative models of the biological substrate of object recognition, we ask: can a single ventral stream neuronal linking hypothesis quantitatively account for core object recognition performance over a broad range of tasks? We measured human performance in 64 object recognition tests using thousands of challenging images that explore shape similarity and identity preserving object variation. We then used multielectrode arrays to measure neuronal population responses to those same images in visual areas V4 and inferior temporal (IT) cortex of monkeys and simulated V1 population responses. We tested leading candidate linking hypotheses and control hypotheses, each postulating how ventral stream neuronal responses underlie object recognition behavior. Specifically, for each hypothesis, we computed the predicted performance on the 64 tests and compared it with the measured pattern of human performance. All tested hypotheses based on low- and mid-level visually evoked activity (pixels, V1, and V4) were very poor predictors of the human behavioral pattern. However, simple learned weighted sums of distributed average IT firing rates exactly predicted the behavioral pattern. More elaborate linking hypotheses relying on IT trial-by-trial correlational structure, finer IT temporal codes, or ones that strictly respect the known spatial substructures of IT (“face patches”) did not improve predictive power. Although these results do not reject those more elaborate hypotheses, they suggest a simple, sufficient quantitative model: each object recognition task is learned from the spatially distributed mean firing rates (100 ms) of ∼60,000 IT neurons and is executed as a simple weighted sum of those firing rates. SIGNIFICANCE STATEMENT We sought to go beyond qualitative models of visual object recognition and determine whether a single neuronal linking hypothesis can quantitatively account for core object recognition behavior. To achieve this, we designed a database of images for evaluating object recognition performance. We used multielectrode arrays to characterize hundreds of neurons in the visual ventral stream of nonhuman primates and measured the object recognition performance of >100 human observers. Remarkably, we found that simple learned weighted sums of firing rates of neurons in monkey inferior temporal (IT) cortex accurately predicted human performance. Although previous work led us to expect that IT would outperform V4, we were surprised by the quantitative precision with which simple IT-based linking hypotheses accounted for human behavior. PMID:26424887

  7. Comparing visual representations across human fMRI and computational vision

    PubMed Central

    Leeds, Daniel D.; Seibert, Darren A.; Pyles, John A.; Tarr, Michael J.

    2013-01-01

    Feedforward visual object perception recruits a cortical network that is assumed to be hierarchical, progressing from basic visual features to complete object representations. However, the nature of the intermediate features related to this transformation remains poorly understood. Here, we explore how well different computer vision recognition models account for neural object encoding across the human cortical visual pathway as measured using fMRI. These neural data, collected during the viewing of 60 images of real-world objects, were analyzed with a searchlight procedure as in Kriegeskorte, Goebel, and Bandettini (2006): Within each searchlight sphere, the obtained patterns of neural activity for all 60 objects were compared to model responses for each computer recognition algorithm using representational dissimilarity analysis (Kriegeskorte et al., 2008). Although each of the computer vision methods significantly accounted for some of the neural data, among the different models, the scale invariant feature transform (Lowe, 2004), encoding local visual properties gathered from “interest points,” was best able to accurately and consistently account for stimulus representations within the ventral pathway. More generally, when present, significance was observed in regions of the ventral-temporal cortex associated with intermediate-level object perception. Differences in model effectiveness and the neural location of significant matches may be attributable to the fact that each model implements a different featural basis for representing objects (e.g., more holistic or more parts-based). Overall, we conclude that well-known computer vision recognition systems may serve as viable proxies for theories of intermediate visual object representation. PMID:24273227

  8. Heart Rate Variability as a Measure of Airport Ramp-Traffic Controllers Workload

    NASA Technical Reports Server (NTRS)

    Hayashi, Miwa; Dulchinos, Victoria Lee

    2016-01-01

    Heart Rate Variability (HRV) has been reported to reflect the person's cognitive and emotional stress levels, and may offer an objective measure of human-operator's workload levels, which are recorded continuously and unobtrusively to the task performance. The present paper compares the HRV data collected during a human-in-the-loop simulation of airport ramp-traffic control operations with the controller participants' own verbal self-reporting ratings of their workload.

  9. Development of a Novel, Objective Measure of Health Care–Related Financial Burden for U.S. Families with Children

    PubMed Central

    Wisk, Lauren E; Gangnon, Ronald; Vanness, David J; Galbraith, Alison A; Mullahy, John; Witt, Whitney P

    2014-01-01

    Objective To develop and validate a theoretically based and empirically driven objective measure of financial burden for U.S. families with children. Data Sources The measure was developed using 149,021 families with children from the National Health Interview Survey, and it was validated using 18,488 families with children from the Medical Expenditure Panel Survey. Study Design We estimated the marginal probability of unmet health care need due to cost using a bivariate tensor product spline for family income and out-of-pocket health care costs (OOPC; e.g., deductibles, copayments), while adjusting for confounders. Recursive partitioning was performed on these probabilities, as a function of income and OOPC, to establish thresholds demarcating levels of predicted risk. Principal Findings We successfully generated a novel measure of financial burden with four categories that were associated with unmet need (vs. low burden: midlow OR: 1.93, 95 percent CI: 1.78–2.09; midhigh OR: 2.78, 95 percent CI: 2.49–3.10; high OR: 4.38, 95 percent CI: 3.99–4.80). The novel burden measure demonstrated significantly better model fit and less underestimation of financial burden compared to an existing measure (OOPC/income ≥10 percent). Conclusion The newly developed measure of financial burden establishes thresholds based on different combinations of family income and OOPC that can be applied in future studies of health care utilization and expenditures and in policy development and evaluation. PMID:25328073

  10. Reach and Validity of An Objective Medication Adherence Measure among Safety Net Health Plan Members with Diabetes: A Cross-Sectional Study

    PubMed Central

    Ratanawongsa, Neda; Karter, Andrew J.; Quan, Judy; Parker, Melissa M.; Handley, Margaret; Sarkar, Urmimala; Schmittdiel, Julie A.; Schillinger, Dean

    2015-01-01

    Background With the expansion of Medicaid and low-cost health insurance plans among diverse patient populations, objective measures of medication adherence using pharmacy claims could advance clinical care and translational research for safety net care. However, safety net patients may experience fluctuating prescription drug coverage, affecting the performance of adherence measures. Objective To evaluate the performance of continuous medication gap (CMG) for diverse, low-income managed care members with diabetes. Methods We conducted this cross-sectional analysis using administrative and clinical data for 680 members eligible for a self-management support trial at a non-profit, government-sponsored managed care plan. We applied CMG methodology to cardiometabolic medication claims for English-, Cantonese-, or Spanish-speaking members with diabetes. We examined inclusiveness (the proportion with calculable CMG) and selectivity (sociodemographic and medical differences from members without CMG). To examine validity, we examined unadjusted associations of suboptimal adherence (CMG>20%) with suboptimal cardiometabolic control. Results 429 members (63%) had calculable CMG. Compared to members without CMG, members with CMG were younger; more likely employed; and had poorer glycemic control, but better blood pressure and lipid control. Suboptimal adherence occurred more frequently among members with poor cardiometabolic control than among members with optimal control (28% vs. 12%, p=0.02). Conclusions CMG demonstrated acceptable inclusiveness and validity in a diverse, low-income safety net population, comparable to its performance in studies among other insured populations. CMG may provide a useful tool to measure adherence among increasingly diverse Medicaid populations, complemented by other strategies to reach those not captured by CMG. Trial Registration NCT00683020 PMID:26233541

  11. Validity and inter-observer reliability of subjective hand-arm vibration assessments.

    PubMed

    Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen

    2014-07-01

    Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. "Did you call me?" 5-month-old infants own name guides their attention.

    PubMed

    Parise, Eugenio; Friederici, Angela D; Striano, Tricia

    2010-12-03

    An infant's own name is a unique social cue. Infants are sensitive to their own name by 4 months of age, but whether they use their names as a social cue is unknown. Electroencephalogram (EEG) was measured as infants heard their own name or stranger's names and while looking at novel objects. Event related brain potentials (ERPs) in response to names revealed that infants differentiate their own name from stranger names from the first phoneme. The amplitude of the ERPs to objects indicated that infants attended more to objects after hearing their own names compared to another name. Thus, by 5 months of age infants not only detect their name, but also use it as a social cue to guide their attention to events and objects in the world.

  13. An evaluation of the impact of memory and mood on antiepileptic drug adherence.

    PubMed

    McAuley, James W; Passen, Nina; Prusa, Christine; Dixon, Joanne; Cotterman-Hart, Sheri; Shneker, Bassel F

    2015-02-01

    Antiepileptic drugs are the mainstay of treatment for patients with epilepsy. Adherence to the prescribed regimen is a major factor in achieving a reduced seizure burden, which can decrease morbidity and mortality. Patients with epilepsy oftentimes complain about difficulty with memory. Because little is known about the relationship between memory and mood and adherence, the purpose of this project was to determine the impact of the confounding factors of memory and mood on antiepileptic drug adherence in patients with epilepsy. One hundred adult patients with epilepsy were recruited from the outpatient neurology clinic for this cross-sectional study. Patients who met the inclusion criteria completed measures of subjective memory (subset of 6 memory questions from the QOLIE-89) and objective memory (Hopkins Verbal Learning Test - Revised), subjective adherence (Morisky scale) and objective adherence (medication possession ratio), and mood (Neurological Disorders Depression Inventory for Epilepsy). Refill records from each patient's community pharmacy were used to objectively assess adherence. Medication possession ratios were calculated based on the antiepileptic drug refill records over the previous 6months. Patients were considered adherent if their MPR was >80%. Women made up the majority of the sample (n=59), and, on average, patients had been living with epilepsy for nearly 20years. Approximately 40% of the sample were on antiepileptic drug monotherapy; most patients (>70%) took their antiepileptic drugs twice daily, and the mean number of total medications was 4.25±2.98. Based on the objective measure of adherence, 35% of the patients were nonadherent. Patients self-reported better adherence than what was objectively measured. Only the retention metric of the objective memory measure differentiated adherent patients from nonadherent patients. Patients in the adherent group had significantly lower depression scores (indicating better mood) compared with those in the nonadherent group (p=0.04). Objective memory measures were not robustly correlated with adherence. However, we observed that patients with higher depressed mood scores were more likely to be nonadherent. By targeting patients with epilepsy and comorbid depression, practitioners may identify patients at greatest risk of nonadherence and subsequent harm. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Application of vaginal temperature measurement in bitches.

    PubMed

    Maeder, B; Arlt, S; Burfeind, O; Heuwieser, W

    2012-12-01

    Finding innovative, non-invasive methods for continuously measuring body temperature minimizing human interference is important for accurate data collection. The objective of this study was to assess feasibility and accuracy of continuous body temperature measurements with loggers placed in the vaginal cavity of bitches. First, an in vitro experiment was performed to compare values obtained by temperature loggers (n = 26) to a calibrated liquid-in-glass thermometer. The mean differences between the two methods were low. Next, an in vivo experiment was performed using five healthy bitches, and values obtained by the vaginal loggers were compared to measurements collected rectally with digital thermometers. The results show that rectal and vaginal temperatures were correlated. The mean differences between rectal and vaginal temperatures were negligible. We conclude that the utilized temperature loggers provide accurate and reliable data. © 2012 Blackwell Verlag GmbH.

  15. The importance of quantitative measurement methods for uveitis: laser flare photometry endorsed in Europe while neglected in Japan where the technology measuring quantitatively intraocular inflammation was developed.

    PubMed

    Herbort, Carl P; Tugal-Tutkun, Ilknur

    2017-06-01

    Laser flare photometry (LFP) is an objective and quantitative method to measure intraocular inflammation. The LFP technology was developed in Japan and has been commercially available since 1990. The aim of this work was to review the application of LFP in uveitis practice in Europe compared to Japan where the technology was born. We reviewed PubMed articles published on LFP and uveitis. Although LFP has been largely integrated in routine uveitis practice in Europe, it has been comparatively neglected in Japan and still has not received FDA approval in the USA. As LFP is the only method that provides a precise measure of intraocular inflammation, it should be used as a gold standard in uveitis centres worldwide.

  16. In-Vacuum Photogrammetry of a 10-Meter Solar Sail

    NASA Technical Reports Server (NTRS)

    Meyer, Chris G.; Jones, Thomas W.; Lunsford, Charles B.; Pappa, Richard S.

    2005-01-01

    In July 2004, a 10-meter solar sail structure developed by L Garde, Inc. was tested in vacuum at the NASA Glenn 30-meter Plum Brook Space Power Facility in Sandusky, Ohio. The three main objections of the test were to demonstrate unattended deployment from a stowed configuration, to measure the deployed shape of the sail at both ambient and cryogenic room temperatures, and to measure the deployed structural dynamic characteristics (vibration modes). This paper summarizes the work conducted to fulfill the second test objective. The deployed shape was measured photogrammetrically in vacuum conditions with four 2-megapixel digital video cameras contained in custom made pressurized canisters. The canisters included high-intensity LED ring lights to illuminate a grid of retroreflective targets distributed on the solar sail. The test results closely matched pre-test photogrammetry numerical simulations and compare well with ABAQUS finite-element model predictions.

  17. Airborne Dioxins, Furans and Polycyclic Aromatic Hydrocarbons Exposure to Military Personnel in Iraq

    PubMed Central

    Masiol, Mauro; Mallon, Timothy; Haines, Kevin M.; Utell, Mark J.; Hopke, Philip K.

    2016-01-01

    Objectives The objective was to use ambient polycyclic aromatic hydrocarbon (PAH), polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) concentrations measured at Joint Base Balad in Iraq in 2007 to identify the sources of these species and their spatial patterns. Methods The ratios of the measured species were compared to literature data for likely emission sources. Using the multiple site measurements on specific days, contour maps have been drawn using inverse distance weighting (IDW). Results These analyses suggest multiple sources including the burn pit (primarily a source of PCDD/PCDFs), the transportation field (primarily as source of PAHs) and other sources of PAHs that include aircraft, space heating, and diesel power generation. Conclusions The nature and locations of the sources were identified. PCDD/PCDFs were emitted by the burn pit. Multiple PAH sources exist across the base. PMID:27501100

  18. Accuracy assessment of the Precise Point Positioning method applied for surveys and tracking moving objects in GIS environment

    NASA Astrophysics Data System (ADS)

    Ilieva, Tamara; Gekov, Svetoslav

    2017-04-01

    The Precise Point Positioning (PPP) method gives the users the opportunity to determine point locations using a single GNSS receiver. The accuracy of the determined by PPP point locations is better in comparison to the standard point positioning, due to the precise satellite orbit and clock corrections that are developed and maintained by the International GNSS Service (IGS). The aim of our current research is the accuracy assessment of the PPP method applied for surveys and tracking moving objects in GIS environment. The PPP data is collected by using preliminary developed by us software application that allows different sets of attribute data for the measurements and their accuracy to be used. The results from the PPP measurements are directly compared within the geospatial database to different other sets of terrestrial data - measurements obtained by total stations, real time kinematic and static GNSS.

  19. Experimental study of acoustic radiation force of an ultrasound beam on absorbing and scattering objects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nikolaeva, Anastasiia V., E-mail: niko200707@mail.ru; Kryzhanovsky, Maxim A.; Tsysar, Sergey A.

    Acoustic radiation force is a nonlinear acoustic effect caused by the transfer of wave momentum to absorbing or scattering objects. This phenomenon is exploited in modern ultrasound metrology for measurement of the acoustic power radiated by a source and is used for both therapeutic and diagnostic sources in medical applications. To calculate radiation force an acoustic hologram can be used in conjunction with analytical expressions based on the angular spectrum of the measured field. The results of an experimental investigation of radiation forces in two different cases are presented in this paper. In one case, the radiation force of anmore » obliquely incident ultrasound beam on a large absorber (which completely absorbs the beam) is considered. The second case concerns measurement of the radiation force on a spherical target that is small compared to the beam diameter.« less

  20. Passive vs. active safety belt systems in Volkswagen rabbits : a comparison of owner use habits and attitudes

    DOT National Transportation Integrated Search

    1976-08-01

    The overall objective of this research is to measure usage of, and attitudes toward, the passive restraint system, compared with the active restraint system on 1975 model year Volkswagen Rabbits. Methods used to carry out the research include: Interv...

  1. Seven Criteria for an Effective Classroom Environment

    ERIC Educational Resources Information Center

    Ediger, Marlow

    2009-01-01

    There are a plethora of variables which affect pupils in the classroom. These might involve the obvious such as uncomfortable temperature readings a well as the following: (1) small group work as compared to individual activities; (2) use of measurably stated objectives versus constructivism as psychologies of learning; (3) a very quiet…

  2. Importance of fuel treatment for limiting moderate-to-high intensity fire: Findings from comparative fire modeling

    Treesearch

    Geoffrey J. Cary; Ian D. Davies; Ross A. Bradstock; Robert E. Keane; Mike D. Flannigan

    2017-01-01

    Context: Wildland fire intensity influences natural communities, soil properties, erosion, and sequestered carbon. Measuring effectiveness of fuel treatment for reducing area of higher intensity unplanned fire is argued to be more meaningful than determining effect on total unplanned area burned. Objectives...

  3. Executive Function and ADHD: A Comparison of Children's Performance during Neuropsychological Testing and Real-World Activities

    ERIC Educational Resources Information Center

    Lawrence, Vivienne; Houghton, Stephen; Douglas, Graham; Durkin, Kevin; Whiting, Ken; Tannock, Rosemary

    2004-01-01

    Objective: Current understanding of executive function deficits in Attention-Deficit/Hyperactivity Disorder (ADHD) is derived almost exclusively from neuropsychological testing conducted in laboratory settings. This study compared children's performance on both neuropsychological and real-life measures of executive function and processing speed.…

  4. The Michigan Public High School Context and Performance Report Card

    ERIC Educational Resources Information Center

    Van Beek, Michael; Bowen, Daniel; Mills, Jonathan

    2012-01-01

    Assessing a high school's effectiveness is not straightforward. Comparing a school's standardized test scores to those of other schools is one approach to measuring effectiveness, but a major objection to this method is that students' test scores tend to be related to students' "socioeconomic" status--family household income, for…

  5. Participation in International Large-Scale Assessments from a US Perspective

    ERIC Educational Resources Information Center

    Plisko, Valena White

    2013-01-01

    International large-scale assessments (ILSAs) play a distinct role in the United States' decentralized federal education system. Separate from national and state assessments, they offer an external, objective measure for the United States to assess student performance comparatively with other countries and over time. The US engagement in ILSAs…

  6. VISUALLY OBSERVED MOLD AND MOLDY ODOR VERSUS QUANTITATIVELY MEASURED MICROBIAL EXPOSURE IN HOMES

    EPA Science Inventory

    The main study objective was to compare different methods for assessing mold exposure in conjunction with an epidemiologic study on the development of children's asthma. Homes of 184 children were assessed for mold by visual observations and dust sampling at child's age 1 (Year ...

  7. Memory and Learning in Pediatric Bipolar Disorder.

    ERIC Educational Resources Information Center

    McClure, Erin B.; Treland, Julia E.; Snow, Joseph; Dickstein, Daniel P.; Towbin, Kenneth E.; Charney, Dennis S.; Pine, Daniel S.; Leibenluft, Ellen

    2005-01-01

    Objective: To test the hypothesis that patients with pediatric bipolar disorder (PBPD) would demonstrate impairment relative to diagnosis-free controls of comparable age, gender, and IQ on measures of memory functioning. Method: The authors administered a battery of verbal and visuospatial memory tests to 35 outpatients with PBPD and 20 healthy…

  8. Racist Experiences and Health Outcomes: An Examination of Spirituality as a Buffer.

    ERIC Educational Resources Information Center

    Bowen-Reid, Terra L.; Harrell, Jules P.

    2002-01-01

    Examined whether perception of racist experiences would predict differently for self-reported health symptoms compared to an objective health measure (cardiovascular reactivity) among African Americans, noting the influence of spirituality. Perceived racist experiences and racial stress negatively related to health symptoms and inversely related…

  9. A Survey Version of Full-Profile Conjoint Analysis.

    ERIC Educational Resources Information Center

    Chrzan, Keith

    Two studies were conducted to test the viability of a survey version of full-profile conjoint analysis. Conjoint analysis describes a variety of analytic techniques for measuring subjects'"utilities," or preferences for the individual attributes or levels of attributes that constitute objects under study. The first study compared the…

  10. Self-Assessment and Continuing Professional Development: The Canadian Perspective

    ERIC Educational Resources Information Center

    Silver, Ivan; Campbell, Craig; Marlow, Bernard; Sargeant, Joan

    2008-01-01

    Introduction: Several recent studies highlight that physicians are not very accurate at assessing their competence in clinical domains when compared to objective measures of knowledge and performance. Instead of continuing to try to train physicians to be more accurate self-assessors, the research suggests that physicians will benefit from…

  11. Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System

    PubMed Central

    Koenen, Paola; Schneider, Marco M.; Fröhlich, Matthias; Driessen, Arne; Bouillon, Bertil; Bäthis, Holger

    2016-01-01

    Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA. PMID:27313898

  12. Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function

    PubMed Central

    Hunt, O A; Wolffsohn, J S; Gilmartin, B

    2003-01-01

    Background/aim: The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim of this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany). Method: The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autorefraction (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session. Results: On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference +0.05 (0.63) D, p = 0.41) and more negative than the SRW-5000 prescription (by −0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of −8.75D to +4.00D (mean spherical equivalent) examined. Conclusion: The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types. PMID:14660462

  13. Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function.

    PubMed

    Hunt, O A; Wolffsohn, J S; Gilmartin, B

    2003-12-01

    The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim of this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany). The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autorefraction (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session. On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference +0.05 (0.63) D, p=0.41) and more negative than the SRW-5000 prescription (by -0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of -8.75D to +4.00D (mean spherical equivalent) examined. The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types.

  14. Correspondence of Parent Report and Laboratory Measures of Inattention and Hyperactivity in Children with Heavy Prenatal Alcohol Exposure

    PubMed Central

    Glass, Leila; Graham, Diana M.; Deweese, Benjamin N.; Jones, Kenneth Lyons; Riley, Edward P.; Mattson, Sarah N.

    2014-01-01

    Clinical research and practice support a multi-method approach to validating behavioral problems in children. We examined whether parent-reported symptoms of hyperactivity and inattention (using the Disruptive Behavior Disorder Rating Scale) were substantiated by objective laboratory measures [hyperactivity measured by wrist-worn actigraphy (ACT) and inattention assessed using a 20-minute continuous performance task (CPT)] in three age- and demographically-matched groups of school-age children: children with prenatal alcohol exposure (AE), non-exposed children with idiopathic ADHD (ADHD), and controls (CON). Results indicated that the clinical groups (AE, ADHD) had significantly higher parent-reported levels for both domains compared to the CON group, and did not differ from each other. On the laboratory measures, the clinical groups were more inattentive than controls on the CPT, but did not differ from each other. In contrast, the ADHD group had higher objective activity on the ACT than AE and CON, which did not differ from each other. Thus, laboratory measures differentially validated parent reports in a group-dependent manner. Actigraphy substantiated parent-reported hyperactivity for children in the ADHD group but not for children in the AE group, while the CPT validated parent-reported inattention for both clinical groups. Although the majority of children in the AE group met criteria for ADHD, objective activity levels were not different from controls, indicating that hyperactivity may be a less prominent feature in the AE group. Thus, while there is considerable overlap between the effects of prenatal alcohol exposure and ADHD, differences in behavioral profiles may be clinically useful in differential diagnosis. Further, these data indicate that objective measures should be used to validate parent reports. PMID:24512965

  15. Quantifying learning in medical students during a critical care medicine elective: a comparison of three evaluation instruments.

    PubMed

    Rogers, P L; Jacob, H; Rashwan, A S; Pinsky, M R

    2001-06-01

    To compare three different evaluative instruments and determine which is able to measure different aspects of medical student learning. Student learning was evaluated by using written examinations, objective structured clinical examination, and patient simulator that used two clinical scenarios before and after a structured critical care elective, by using a crossover design. Twenty-four 4th-yr students enrolled in the critical care medicine elective. All students took a multiple-choice written examination; evaluated a live simulated critically ill patient, requested data from a nurse, and intervened as appropriate at different stations (objective structured clinical examination); and evaluated the computer-controlled patient simulator and intervened as appropriate. Students' knowledge was assessed by using a multiple-choice examination containing the same data incorporated into the other examinations. Student performance on the objective structured clinical examination was evaluated at five stations. Both objective structured clinical examination and simulator tests were videotaped for subsequent scores of responses, quality of responses, and response time. The videotapes were reviewed for specific behaviors by faculty masked to time of examination. Students were expected to perform the following: a) assess airway, breathing, and circulation; b) prepare a mannequin for intubation; c) provide appropriate ventilator settings; d) manage hypotension; and e) request, interpret, and provide appropriate intervention for pulmonary artery catheter data. Students were expected to perform identical behaviors during the simulator examination; however, the entire examination was performed on the whole-body computer-controlled mannequin. The primary outcome measure was the difference in examination scores before and after the rotation. The mean preelective scores were 77 +/- 16%, 47 +/- 15%, and 41 +/- 14% for the written examination, objective structured clinical examination, and simulator, respectively, compared with 89 +/- 11%, 76 +/- 12%, and 62 +/- 15% after the elective (p <.0001). Prerotation scores for the written examination were significantly higher than the objective structured clinical examination or the simulator; postrotation scores were highest for the written examination and lowest for the simulator. Written examinations measure acquisition of knowledge but fail to predict if students can apply knowledge to problem solving, whereas both the objective structured clinical examination and the computer-controlled patient simulator can be used as effective performance evaluation tools.

  16. Liquid-Crystal Point-Diffraction Interferometer for Wave-Front Measurements

    NASA Technical Reports Server (NTRS)

    Mercer, Carolyn R.; Creath, Katherine

    1996-01-01

    A new instrument, the liquid-crystal point-diffraction interferometer (LCPDI), is developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point-diffraction interferometer and adds to it a phase-stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave fronts with very high data density and with automated data reduction. We describe the theory and design of the LCPDI. A focus shift was measured with the LCPDI, and the results are compared with theoretical results,

  17. The Impact of Magnesium Sulfate Therapy on Angiogenic Factors in Preeclampsia

    PubMed Central

    VADNAIS, Mary A.; RANA, Sarosh; QUANT, Hayley S.; SALAHUDDIN, Saira; DODGE, Laura E.; LIM, Kee-Hak; KARUMANCHI, S. Ananth; HACKER, Michele R.

    2011-01-01

    Objective The objective was to evaluate whether intravenous magnesium sulfate (magnesium) alters levels of angiogenic factors in women with preeclampsia. Study Design This was a prospective cohort study comparing women with preeclampsia treated with magnesium for seizure prophylaxis to those who were not. Serum levels of angiogenic factors, soluble fms-like tyrosine kinase 1, soluble endoglin and placental growth factor, were measured at the time of diagnosis and approximately 24 hours later. Secondary analysis compared women receiving magnesium for preeclampsia to women receiving magnesium for preterm labor. Analysis of covariance was used to compare levels at 24 hours, adjusting for levels at enrollment and potential confounders. Results Angiogenic factor levels did not differ between preeclampsia groups with and without magnesium or between preeclampsia and preterm labor groups treated with magnesium (all P > 0.05). Conclusion Magnesium likely decreases seizure risk in preeclampsia by a mechanism other than altering angiogenic factor levels. PMID:22247820

  18. The Impact of Magnesium Sulfate Therapy on Angiogenic Factors in Preeclampsia.

    PubMed

    Vadnais, Mary A; Rana, Sarosh; Quant, Hayley S; Salahuddin, Saira; Dodge, Laura E; Lim, Kee-Hak; Karumanchi, S Ananth; Hacker, Michele R

    2012-01-01

    OBJECTIVE: The objective was to evaluate whether intravenous magnesium sulfate (magnesium) alters levels of angiogenic factors in women with preeclampsia. STUDY DESIGN: This was a prospective cohort study comparing women with preeclampsia treated with magnesium for seizure prophylaxis to those who were not. Serum levels of angiogenic factors, soluble fms-like tyrosine kinase 1, soluble endoglin and placental growth factor, were measured at the time of diagnosis and approximately 24 hours later. Secondary analysis compared women receiving magnesium for preeclampsia to women receiving magnesium for preterm labor. Analysis of covariance was used to compare levels at 24 hours, adjusting for levels at enrollment and potential confounders. RESULTS: Angiogenic factor levels did not differ between preeclampsia groups with and without magnesium or between preeclampsia and preterm labor groups treated with magnesium (all P > 0.05). CONCLUSION: Magnesium likely decreases seizure risk in preeclampsia by a mechanism other than altering angiogenic factor levels.

  19. Multirate and event-driven Kalman filters for helicopter flight

    NASA Technical Reports Server (NTRS)

    Sridhar, Banavar; Smith, Phillip; Suorsa, Raymond E.; Hussien, Bassam

    1993-01-01

    A vision-based obstacle detection system that provides information about objects as a function of azimuth and elevation is discussed. The range map is computed using a sequence of images from a passive sensor, and an extended Kalman filter is used to estimate range to obstacles. The magnitude of the optical flow that provides measurements for each Kalman filter varies significantly over the image depending on the helicopter motion and object location. In a standard Kalman filter, the measurement update takes place at fixed intervals. It may be necessary to use a different measurement update rate in different parts of the image in order to maintain the same signal to noise ratio in the optical flow calculations. A range estimation scheme that accepts the measurement only under certain conditions is presented. The estimation results from the standard Kalman filter are compared with results from a multirate Kalman filter and an event-driven Kalman filter for a sequence of helicopter flight images.

  20. A 100,000 Scale Factor Radar Range.

    PubMed

    Blanche, Pierre-Alexandre; Neifeld, Mark; Peyghambarian, Nasser

    2017-12-19

    The radar cross section of an object is an important electromagnetic property that is often measured in anechoic chambers. However, for very large and complex structures such as ships or sea and land clutters, this common approach is not practical. The use of computer simulations is also not viable since it would take many years of computational time to model and predict the radar characteristics of such large objects. We have now devised a new scaling technique to overcome these difficulties, and make accurate measurements of the radar cross section of large items. In this article we demonstrate that by reducing the scale of the model by a factor 100,000, and using near infrared wavelength, the radar cross section can be determined in a tabletop setup. The accuracy of the method is compared to simulations, and an example of measurement is provided on a 1 mm highly detailed model of a ship. The advantages of this scaling approach is its versatility, and the possibility to perform fast, convenient, and inexpensive measurements.

Top