Cryptanalysis and Improvements for the Quantum Private Comparison Protocol Using EPR Pairs
NASA Astrophysics Data System (ADS)
Wang, Cong; Xu, Gang; Yang, Yi-Xian
2013-07-01
In this paper, we carry out an in-depth analysis of the quantum private comparison (QPC) protocol with the semi-honest third party (TP). The security of QPC protocol using the EPR pairs is re-examined. Unfortunately, we find that TP can use the fake EPR pairs to steal all the secret information. Furthermore, we give two simple and feasible solutions to improve the original QPC protocol. It is shown that the improved protocol is secure, which can resist various kinds of attacks from both the outside eavesdroppers and the inside participants, even the semi-honest TP.
NASA Astrophysics Data System (ADS)
Ye, Tian-Yu
2016-09-01
Recently, Liu et al. proposed a two-party quantum private comparison (QPC) protocol using entanglement swapping of Bell entangled state (Commun. Theor. Phys. 57 (2012) 583). Subsequently Liu et al. pointed out that in Liu et al.'s protocol, the TP can extract the two users' secret inputs without being detected by launching the Bell-basis measurement attack, and suggested the corresponding improvement to mend this loophole (Commun. Theor. Phys. 62 (2014) 210). In this paper, we first point out the information leakage problem toward TP existing in both of the above two protocols, and then suggest the corresponding improvement by using the one-way hash function to encrypt the two users' secret inputs. We further put forward the three-party QPC protocol also based on entanglement swapping of Bell entangled state, and then validate its output correctness and its security in detail. Finally, we generalize the three-party QPC protocol into the multi-party case, which can accomplish arbitrary pair's comparison of equality among K users within one execution. Supported by the National Natural Science Foundation of China under Grant No. 61402407
NASA Astrophysics Data System (ADS)
Xu, Ling; Zhao, Zhiwen
2017-12-01
Quantum private comparison (QPC) protocol, including Alice, Bob and the third party Charlie, aims at comparing Alice and Bob's secret inputs correctly without leaking them. Firstly, χ ^+ state and W-Class state are used to conduct the entanglement swapping in this protocol. Either the basis {|φ ^± > ,|ψ ^± >} or the basis {|χ ^± > ,|ω ^± > } is chosen by Alice and Bob based on the predetermined value to measure the particle pairs. And three bits of secret inputs can be compared in this protocol in every comparison time, while most of previous QPC protocols can only compare one or two bits. The qubit efficiency of this protocol is 60% more than others, which are 50% at most. Secondly, if the eavesdropper intends to obtain the secret inputs, it is important and primary to get the measurement results of particle pairs. In this protocol, even if the eavesdropper gets the accurate particle pairs, he cannot get the right measurement results without the right basis. Finally, this protocol is analyzed to be able to defend the secret inputs against various kinds of attack.
Improvements of Quantum Private Comparison Protocol Based on Cluster States
NASA Astrophysics Data System (ADS)
Zhou, Ming-Kuai
2018-01-01
Quantum private comparison aims to determine whether the secrets from two different users are equal or not by utilizing the laws of quantum mechanics. Recently, Sun and Long put forward a quantum private comparison (QPC) protocol by using four-particle cluster states (Int. J. Theor. Phys. 52, 212-218, 2013). In this paper, we investigate this protocol in depth, and suggest the corresponding improvements. Compared with the original protocol, the improved protocol has the following advantages: 1) it can release the requirements of authenticated classical channels and unitary operations; 2) it can prevent the malicious attack from the genuine semi-honest TP; 3) it can enhance the qubit efficiency.
Quantum Private Comparison Protocol with Linear Optics
NASA Astrophysics Data System (ADS)
Luo, Qing-bin; Yang, Guo-wu; She, Kun; Li, Xiaoyu
2016-12-01
In this paper, we propose an innovative quantum private comparison(QPC) protocol based on partial Bell-state measurement from the view of linear optics, which enabling two parties to compare the equality of their private information with the help of a semi-honest third party. Partial Bell-state measurement has been realized by using only linear optical elements in experimental measurement-device-independent quantum key distribution(MDI-QKD) schemes, which makes us believe that our protocol can be realized in the near future. The security analysis shows that the participants will not leak their private information.
NASA Astrophysics Data System (ADS)
Gao, Xiang; Zhang, Shi-Bin; Chang, Yan; Yang, Fan; Zhang, Yan
2018-02-01
Recently, Li et al. (Int. J. Theor. Phys. 55, 1710-1718, 2016) proposed a Quantum Private Comparison (QPC) protocol based on the Entanglement Swapping Between Three-Particle W-Class State and Bell State. Two parties can check whether their secret information is equal or not with the help of the semi-honest third party (TP). However in this paper, we will point out this kind of semi-honest TP is unreasonable. If we relax the constraint of the semi-honest TP, by using the fake signal attack, TP can know the whole secret information illegally. At last, we give our improvement, which can make this protocol more secure.
NASA Astrophysics Data System (ADS)
Gao, Xiang; Zhang, Shi-Bin; Chang, Yan; Yang, Fan; Zhang, Yan
2018-06-01
Recently, Li et al. (Int. J. Theor. Phys. 55, 1710-1718, 2016) proposed a Quantum Private Comparison (QPC) protocol based on the Entanglement Swapping Between Three-Particle W-Class State and Bell State. Two parties can check whether their secret information is equal or not with the help of the semi-honest third party (TP). However in this paper, we will point out this kind of semi-honest TP is unreasonable. If we relax the constraint of the semi-honest TP, by using the fake signal attack, TP can know the whole secret information illegally. At last, we give our improvement, which can make this protocol more secure.
Measuring quality in community based housing support - the QPC-H instrument.
Lundqvist, Lars-Olov; Rask, Mikael; Brunt, David; Ivarsson, Ann-Britt; Schröder, Agneta
2016-04-18
Purpose - The purpose of this paper is to test the psychometric properties and dimensionality of the instrument Quality in Psychiatric Care-Housing (QPC-H) and briefly describe the residents' perception of quality of housing support. Design/methodology/approach - A sample of 174 residents from 22 housing support services in nine Swedish municipalities participated in the study. Confirmatory factor analysis (CFA) revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the Quality in Psychiatric Care (QPC) family of instruments. Findings - CFA revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the QPC family of instruments. The internal consistency of the factors was acceptable except in the case of secure and secluded environment, probably due to few numbers of items. With this exception, the QPC-H shows adequate psychometric properties. Social implications - The residents' ratings of quality of housing service were generally high; the highest rating was for secluded environment and the lowest for participation. This dimension would thus seem to indicate an important area for improvement. Originality/value - The QPC-H includes important aspects of residents' assessment of quality of housing service and offers a simple and inexpensive way to evaluate housing support services from the residents' perspective.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of QPC Lasers, Inc., Sweet Success Enterprises, Inc., Trinsic, Inc., Veridicom International, Inc., Windswept Environmental Group... securities of QPC Lasers, Inc. because it has not filed any periodic reports since the period ended June 30...
Resistively detected NMR line shapes in a quasi-one-dimensional electron system
NASA Astrophysics Data System (ADS)
Fauzi, M. H.; Singha, A.; Sahdan, M. F.; Takahashi, M.; Sato, K.; Nagase, K.; Muralidharan, B.; Hirayama, Y.
2017-06-01
We observe variation in the resistively detected nuclear magnetic resonance (RDNMR) line shapes in quantum Hall breakdown. The breakdown occurs locally in a gate-defined quantum point contact (QPC) region. Of particular interest is the observation of a dispersive line shape occurring when the bulk two-dimensional electron gas (2DEG) set to νb=2 and the QPC filling factor to the vicinity of νQPC=1 , strikingly resemble the dispersive line shape observed on a 2D quantum Hall state. This previously unobserved line shape in a QPC points to a simultaneous occurrence of two hyperfine-mediated spin flip-flop processes within the QPC. Those events give rise to two different sets of nuclei polarized in the opposite direction and positioned at a separate region with different degrees of electronic spin polarization.
Quantum point contact displacement transducer for a mechanical resonator at sub-Kelvin temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okazaki, Yuma; Mahboob, Imran; Onomitsu, Koji
Highly sensitive displacement transduction of a 1.67 MHz mechanical resonator with a quantum point contact (QPC) formed in a GaAs heterostructure is demonstrated. By positioning the QPC at the point of maximum mechanical strain on the resonator and operating at 80 mK, a displacement responsivity of 3.81 A/m is measured, which represents a two order of magnitude improvement on the previous QPC based devices. By further analyzing the QPC transport characteristics, a sub-Poisson-noise-limited displacement sensitivity of 25 fm/Hz{sup 1/2} is determined which corresponds to a position resolution that is 23 times the standard quantum limit.
The Quebec Pregnancy Cohort – Prevalence of Medication Use during Gestation and Pregnancy Outcomes
Bérard, Anick; Sheehy, Odile
2014-01-01
Purpose We evaluated the potential and the validity of the Quebec Pregnancy Cohort (QPC) as a research tool in perinatal pharmacoepidemiology. Methods The QPC was built by linking four administrative databases: RAMQ (medical and pharmaceutical data), Med-Echo (hospitalizations), ISQ (births/deaths), and MELS (Ministry of Education data). A self-administered questionnaire was sent to a random sample of women to collect lifestyle information. The QPC includes data on all pregnancies of women covered by the Quebec provincial prescription drug insurance between 1998 and 2008. Date of entry in the QPC is the first day of pregnancy, and women are followed during and after pregnancy; children are followed after birth up until 2009. The prevalence of prescribed medications before, during and after pregnancy was compared between time-window. Pregnancy outcomes were also estimated among pregnancies ending with a live born infant. Results The QPC included 289,688 pregnancies of 186,165 women. Among them, 167,398 ended with a delivery representing 19.4% of all deliveries occurring in the Province of Quebec between 1998–2009. The total frequency of abortions was 35.9% in the QPC comparable to the 36.4% observed in the Province of Quebec. The prevalence of prescribed medication use was 74.6%, 59.0%, and 79.6% before, during and after pregnancy, respectively. Although there was a statistically significant decrease in the proportion of use once the pregnancy was diagnosed (p<.01), post-pregnancy prescribed medication use returned above the pre-pregnancy level. The prevalence of pregnancy outcomes found in the QPC were similar to those observed in the Province of Quebec. Conclusion The QPC is an excellent tool for the study of the risk and benefit of drug use during the perinatal period. This cohort has the advantage of including a validated date of beginning of pregnancy giving the possibility of assigning the exact gestational age at the time of maternal exposure. PMID:24705674
The Quebec Pregnancy Cohort--prevalence of medication use during gestation and pregnancy outcomes.
Bérard, Anick; Sheehy, Odile
2014-01-01
We evaluated the potential and the validity of the Quebec Pregnancy Cohort (QPC) as a research tool in perinatal pharmacoepidemiology. The QPC was built by linking four administrative databases: RAMQ (medical and pharmaceutical data), Med-Echo (hospitalizations), ISQ (births/deaths), and MELS (Ministry of Education data). A self-administered questionnaire was sent to a random sample of women to collect lifestyle information. The QPC includes data on all pregnancies of women covered by the Quebec provincial prescription drug insurance between 1998 and 2008. Date of entry in the QPC is the first day of pregnancy, and women are followed during and after pregnancy; children are followed after birth up until 2009. The prevalence of prescribed medications before, during and after pregnancy was compared between time-window. Pregnancy outcomes were also estimated among pregnancies ending with a live born infant. The QPC included 289,688 pregnancies of 186,165 women. Among them, 167,398 ended with a delivery representing 19.4% of all deliveries occurring in the Province of Quebec between 1998-2009. The total frequency of abortions was 35.9% in the QPC comparable to the 36.4% observed in the Province of Quebec. The prevalence of prescribed medication use was 74.6%, 59.0%, and 79.6% before, during and after pregnancy, respectively. Although there was a statistically significant decrease in the proportion of use once the pregnancy was diagnosed (p<.01), post-pregnancy prescribed medication use returned above the pre-pregnancy level. The prevalence of pregnancy outcomes found in the QPC were similar to those observed in the Province of Quebec. The QPC is an excellent tool for the study of the risk and benefit of drug use during the perinatal period. This cohort has the advantage of including a validated date of beginning of pregnancy giving the possibility of assigning the exact gestational age at the time of maternal exposure.
Equilibrium charge fluctuations of a charge detector and its effect on a nearby quantum dot
NASA Astrophysics Data System (ADS)
Ruiz-Tijerina, David; Vernek, Edson; Ulloa, Sergio
2014-03-01
We study the Kondo state of a spin-1/2 quantum dot (QD), in close proximity to a quantum point contact (QPC) charge detector near the conductance regime of the 0.7 anomaly. The electrostatic coupling between the QD and QPC introduces a remote gate on the QD level, which varies with the QPC gate voltage. Furthermore, models for the 0.7 anomaly [Y. Meir et al., PRL 89,196802(2002)] suggest that the QPC lodges a Kondo-screened level with charge-correlated hybridization, which may be also affected by capacitive coupling to the QD, giving rise to a competition between the two Kondo ground states. We model the QD-QPC system as two capacitively-coupled Kondo impurities, and explore the zero-bias transport of both the QD and the QPC for different local gate voltages and coupling strengths, using the numerical renormalization group and variational methods. We find that the capacitive coupling produces a remote gating effect, non-monotonic in the gate voltages, which reduces the gate voltage window for Kondo screening in either impurity, and which can also drive a quantum phase transition out of the Kondo regime. Our study is carried out for intermediate coupling strengths, and as such is highly relevant to experiments; particularly, to recent studies of decoherence effects on QDs. Supported by MWN/CIAM and NSF PIRE.
Shot noise at the quantum point contact in InGaAs heterostructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishihara, Yoshitaka; Nakamura, Shuji; Ono, Teruo
2013-12-04
We study the shot noise at a quantum point contact (QPC) fabricated in an InGaAs/InGaAsP heterostructure, whose conductance can be electrically tuned by the gate voltages. Shot noise suppression is observed at the conductance plateau of N(2e{sup 2}/h) (N = 4,5,and 6), which indicates the coherent quantized channel formation in the QPC. The electron heating effect generated at the QPC explains the deviation of the observed Fano factor from the theory.
Wave-function description of conductance mapping for a quantum Hall electron interferometer
NASA Astrophysics Data System (ADS)
Kolasiński, K.; Szafran, B.
2014-04-01
Scanning gate microscopy of quantum point contacts (QPC) in the integer quantum Hall regime is considered in terms of the scattering wave functions with a finite-difference implementation of the quantum transmitting boundary approach. Conductance (G) maps for a clean QPC as well as for a system including an antidot within the QPC constriction are evaluated. The steplike locally flat G maps for clean QPCs turn into circular resonances that are reentrant in an external magnetic field when the antidot is introduced to the constriction. The current circulation around the antidot and the spacing of the resonances at the magnetic field scale react to the probe approaching the QPC. The calculated G maps with a rigid but soft antidot potential reproduce the features detected recently in the electron interferometer [F. Martins et al., Sci. Rep. 3, 1416 (2013), 10.1038/srep01416].
Staiger, Torben; Wertz, Florian; Xie, Fangqing; Heinze, Marcel; Schmieder, Philipp; Lutzweiler, Christian; Schimmel, Thomas
2018-01-12
Here, we present a silver atomic-scale device fabricated and operated by a combined technique of electrochemical control (EC) and mechanically controllable break junction (MCBJ). With this EC-MCBJ technique, we can perform mechanically controllable bistable quantum conductance switching of a silver quantum point contact (QPC) in an electrochemical environment at room temperature. Furthermore, the silver QPC of the device can be controlled both mechanically and electrochemically, and the operating mode can be changed from 'electrochemical' to 'mechanical', which expands the operating mode for controlling QPCs. These experimental results offer the perspective that a silver QPC may be used as a contact for a nanoelectromechanical relay.
NASA Astrophysics Data System (ADS)
Staiger, Torben; Wertz, Florian; Xie, Fangqing; Heinze, Marcel; Schmieder, Philipp; Lutzweiler, Christian; Schimmel, Thomas
2018-01-01
Here, we present a silver atomic-scale device fabricated and operated by a combined technique of electrochemical control (EC) and mechanically controllable break junction (MCBJ). With this EC-MCBJ technique, we can perform mechanically controllable bistable quantum conductance switching of a silver quantum point contact (QPC) in an electrochemical environment at room temperature. Furthermore, the silver QPC of the device can be controlled both mechanically and electrochemically, and the operating mode can be changed from ‘electrochemical’ to ‘mechanical’, which expands the operating mode for controlling QPCs. These experimental results offer the perspective that a silver QPC may be used as a contact for a nanoelectromechanical relay.
Booker, Kathy; Hilgenberg, Cheryl
2010-01-01
Nursing is often considered expensive in the cost analysis of academic programs. Yet nursing programs have the power to attract many students, and the national nursing shortage has resulted in a high demand for nurses. Methods to systematically assess programs across an entire university academic division are often dissimilar in technique and outcome. At a small, private, Midwestern university, a model for comprehensive program assessment, titled the Quality, Potential and Cost (QPC) model, was developed and applied to each major offered at the university through the collaborative effort of directors, chairs, deans, and the vice president for academic affairs. The QPC model provides a means of equalizing data so that single measures (such as cost) are not viewed in isolation. It also provides a common language to ensure that all academic leaders at an institution apply consistent methods for assessment of individual programs. The application of the QPC model allowed for consistent, fair assessments and the ability to allocate resources to programs according to strategic direction. In this article, the application of the QPC model to School of Nursing majors and other selected university majors will be illustrated. Copyright 2010 Elsevier Inc. All rights reserved.
Khatua, Pradip; Bansal, Bhavtosh; Shahar, Dan
2014-01-10
In a "thought experiment," now a classic in physics pedagogy, Feynman visualizes Young's double-slit interference experiment with electrons in magnetic field. He shows that the addition of an Aharonov-Bohm phase is equivalent to shifting the zero-field wave interference pattern by an angle expected from the Lorentz force calculation for classical particles. We have performed this experiment with one slit, instead of two, where ballistic electrons within two-dimensional electron gas diffract through a small orifice formed by a quantum point contact (QPC). As the QPC width is comparable to the electron wavelength, the observed intensity profile is further modulated by the transverse waveguide modes present at the injector QPC. Our experiments open the way to realizing diffraction-based ideas in mesoscopic physics.
NASA Astrophysics Data System (ADS)
Roldán, J. B.; Miranda, E.; González-Cordero, G.; García-Fernández, P.; Romero-Zaliz, R.; González-Rodelas, P.; Aguilera, A. M.; González, M. B.; Jiménez-Molinos, F.
2018-01-01
A multivariate analysis of the parameters that characterize the reset process in Resistive Random Access Memory (RRAM) has been performed. The different correlations obtained can help to shed light on the current components that contribute in the Low Resistance State (LRS) of the technology considered. In addition, a screening method for the Quantum Point Contact (QPC) current component is presented. For this purpose, the second derivative of the current has been obtained using a novel numerical method which allows determining the QPC model parameters. Once the procedure is completed, a whole Resistive Switching (RS) series of thousands of curves is studied by means of a genetic algorithm. The extracted QPC parameter distributions are characterized in depth to get information about the filamentary pathways associated with LRS in the low voltage conduction regime.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lian, Xiaojuan, E-mail: xjlian2005@gmail.com; Cartoixà, Xavier; Miranda, Enrique
2014-06-28
We depart from first-principle simulations of electron transport along paths of oxygen vacancies in HfO{sub 2} to reformulate the Quantum Point Contact (QPC) model in terms of a bundle of such vacancy paths. By doing this, the number of model parameters is reduced and a much clearer link between the microscopic structure of the conductive filament (CF) and its electrical properties can be provided. The new multi-scale QPC model is applied to two different HfO{sub 2}-based devices operated in the unipolar and bipolar resistive switching (RS) modes. Extraction of the QPC model parameters from a statistically significant number of CFsmore » allows revealing significant structural differences in the CF of these two types of devices and RS modes.« less
Sipes, Carolyn; Baker, Joy Don
2015-09-01
This collaborative study sought to describe technology used by AORN members at work, inclusive of radio-frequency identification or barcode scanning (RFID), data collection tools (DATA), workflow or dashboard management tools (DASHBOARD), and environmental services/room decontamination technologies (ENVIRON), and to identify the perceived effects of each technology on workflow efficiency (WFE) and quality patient care (QPC). The 462 respondents to the AORN Technology in the OR survey reported use of technology (USE) in all categories. Eleven of 17 RFID items had a strong positive correlation between the designated USE item and the perceived effect on WFE and QPC. Five of the most-used technology items were found in the DATA category. Two of the five related to Intraoperative Nursing Documentation and the use of the Perioperative Nursing Data Set. The other three related to Imaging Integration for Radiology Equipment, Video Camera Systems, and Fiber-optic Systems. All three elements explored in the DASHBOARD category (ie, Patient Update, OR Case, OR Efficiency) demonstrated approximately 50% or greater perceived effectiveness in WFE and QPC. There was a low reported use of ENVIRON technologies, resulting in limited WFE and QPC data for this category. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Interactive effects of mechano- and chemo-receptor inputs on cardiorespiratory outputs in the toad.
Wang, T; Taylor, E W; Reid, S G; Milsom, W K
2004-04-20
Arterial blood pressure (P(b)), pulmocutaneous blood flow (Q(pc)), heart rate (f(H)), and fictive ventilation (motor activity in the Vth cranial nerve, V(int)), were recorded from decerebrated, paralysed toads receiving unidirectional ventilation with experimental gas mixtures over a range of lung inflation. At the onset of spontaneous bouts of fictive ventilation, (Q(pc)) and P(b) increased immediately, often with changes in heart rate, implying central cardiorespiratory interactions. Inflation of the lungs with different gas mixtures revealed that the effect of hypercarbia on V(int) was reduced by lung inflation and that feedback from pulmonary stretch receptors may summate with central feedforward control of f(H) and (Q(pc)) in an interactive fashion. The results of bolus injections of cyanide into the carotid or the pulmonary circulations suggest there are oxygen sensitive receptors in both circuits that affect the cardiovascular system directly and respiratory activity by complex central interactions with inputs from central chemoreceptors and pulmonary stretch receptors.
Tunable strength saddle-point contacts impact on quantum rings transmission
NASA Astrophysics Data System (ADS)
González, J. J.; Diago-Cisneros, L.
2016-09-01
A particular subject of investigation is the role of several sadle-point contact (QPC) parameters on the scattering properties of an Aharonov-Bohm-Aharonov-Casher quantum ring (QR) under Rashba-type spin orbit interaction. We discuss the interplay of the conductance with the confinement strengths and height of the QPC, which yields new and tunable harmonic and non-harmonics patterns, while one manipulates these constriction parameters. This phenomenology may be of utility to implement a novel way to modulate spin interference effects in semiconducting QRs, providing an appealing test-platform for spintronics applications.
Onset of Spin Polarization in Four-Gate Quantum Point Contacts
NASA Astrophysics Data System (ADS)
Jones, Alex
A series of simulations which utilize a Non-equilibrium Green's function (NEGF) formalism is suggested which can provide indirect evidence of the fine and non-local electrostatic tuning of the onset of spin polarization in two closely spaced quantum point contacts (QPCs) that experience a phenomenon known as lateral spin-orbit coupling (LSOC). Each of the QPCs that create the device also has its own pair of side gates (SGs) which are in-plane with the device channel. Numerical simulations of the conductance of the two closely spaced QPCs or four-gate QPC are carried out for different biasing conditions applied to two leftmost and rightmost SGs. Conductance plots are then calculated as a function of the variable, Vsweep, which is the common sweep voltage applied to the QPC. When Vsweep is only applied to two of the four side gates, the plots show several conductance anomalies, i.e., below G0 = 2e2/h, characterized by intrinsic bistability, i.e., hysteresis loops due to a difference in the conductance curves for forward and reverse common voltage sweep simulations. The appearance of hysteresis loops is attributed to the co-existence of multistable spin textures in the narrow channel of the four-gate QPC. The shape, location, and number of hysteresis loops are very sensitive to the biasing conditions on the four SGs. The shape and size of the conductance anomalies and hysteresis loops are shown to change when the biasing conditions on the leftmost and rightmost SGs are swapped, a rectifying behavior providing an additional indirect evidence for the onset of spontaneous spin polarization in nanoscale devices made of QPCs. The results of the simulations reveal that the occurrence and fine tuning of conductance anomalies in QPC structures are highly sensitive to the non-local action of closely spaced SGs. It is therefore imperative to take into account this proximity effect in the design of all electrical spin valves making use of middle gates to fine tune the spin precession between QPC based spin injector and detector contacts.
Spin splitting generated in a Y-shaped semiconductor nanostructure with a quantum point contact
NASA Astrophysics Data System (ADS)
Wójcik, P.; Adamowski, J.; Wołoszyn, M.; Spisak, B. J.
2015-07-01
We have studied the spin splitting of the current in the Y-shaped semiconductor nanostructure with a quantum point contact (QPC) in a perpendicular magnetic field. Our calculations show that the appropriate tuning of the QPC potential and the external magnetic field leads to an almost perfect separation of the spin-polarized currents: electrons with opposite spins flow out through different output branches. The spin splitting results from the joint effect of the QPC, the spin Zeeman splitting, and the electron transport through the edge states formed in the nanowire at the sufficiently high magnetic field. The Y-shaped nanostructure can be used to split the unpolarized current into two spin currents with opposite spins as well as to detect the flow of the spin current. We have found that the separation of the spin currents is only slightly affected by the Rashba spin-orbit coupling. The spin-splitter device is an analogue of the optical device—the birefractive crystal that splits the unpolarized light into two beams with perpendicular polarizations. In the magnetic-field range, in which the current is carried through the edges states, the spin splitting is robust against the spin-independent scattering. This feature opens up a possibility of the application of the Y-shaped nanostructure as a non-ballistic spin-splitter device in spintronics.
Interference Effects in a Tunable Quantum Point Contact Integrated with an Electronic Cavity
NASA Astrophysics Data System (ADS)
Yan, Chengyu; Kumar, Sanjeev; Pepper, Michael; See, Patrick; Farrer, Ian; Ritchie, David; Griffiths, Jonathan; Jones, Geraint
2017-08-01
We show experimentally how quantum interference can be produced using an integrated quantum system comprising an arch-shaped short quantum wire (or quantum point contact, QPC) of 1D electrons and a reflector forming an electronic cavity. On tuning the coupling between the QPC and the electronic cavity, fine oscillations are observed when the arch QPC is operated in the quasi-1D regime. These oscillations correspond to interference between the 1D states and a state which is similar to the Fabry-Perot state and suppressed by a small transverse magnetic field of ±60 mT . Tuning the reflector, we find a peak in resistance which follows the behavior expected for a Fano resonance. We suggest that this is an interesting example of a Fano resonance in an open system which corresponds to interference at or near the Ohmic contacts due to a directly propagating, reflected discrete path and the continuum states of the cavity corresponding to multiple scattering. Remarkably, the Fano factor shows an oscillatory behavior taking peaks for each fine oscillation, thus, confirming coupling between the discrete and continuum states. The results indicate that such a simple quantum device can be used as building blocks to create more complex integrated quantum circuits for possible applications ranging from quantum-information processing to realizing the fundamentals of complex quantum systems.
Spin splitting generated in a Y-shaped semiconductor nanostructure with a quantum point contact
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wójcik, P., E-mail: pawel.wojcik@fis.agh.edu.pl; Adamowski, J., E-mail: janusz.adamowski@fis.agh.edu.pl; Wołoszyn, M.
2015-07-07
We have studied the spin splitting of the current in the Y-shaped semiconductor nanostructure with a quantum point contact (QPC) in a perpendicular magnetic field. Our calculations show that the appropriate tuning of the QPC potential and the external magnetic field leads to an almost perfect separation of the spin-polarized currents: electrons with opposite spins flow out through different output branches. The spin splitting results from the joint effect of the QPC, the spin Zeeman splitting, and the electron transport through the edge states formed in the nanowire at the sufficiently high magnetic field. The Y-shaped nanostructure can be usedmore » to split the unpolarized current into two spin currents with opposite spins as well as to detect the flow of the spin current. We have found that the separation of the spin currents is only slightly affected by the Rashba spin-orbit coupling. The spin-splitter device is an analogue of the optical device—the birefractive crystal that splits the unpolarized light into two beams with perpendicular polarizations. In the magnetic-field range, in which the current is carried through the edges states, the spin splitting is robust against the spin-independent scattering. This feature opens up a possibility of the application of the Y-shaped nanostructure as a non-ballistic spin-splitter device in spintronics.« less
Coherence, Charging, and Spin Effects in Quantum Dots and Point Contacts
2001-12-01
requires changing the direction of the external field. Considering the typical fields involved (several tesla) and the high- inductance superconducting ...84 6-5 QPC nonlinear conductance...86 6-6 Nonlinear transconductance colorscales
Development and study of charge sensors for fast charge detection in quantum dots
NASA Astrophysics Data System (ADS)
Thalakulam, Madhu
Charge detection at microsecond time-scales has far reaching consequences in both technology and in our understanding of electron dynamics in nanoscale devices such as quantum dots. Radio-frequency superconducting single electron transistors (RF-SET) and quantum point contacts (QPC) are ultra sensitive charge sensors operating near the quantum limit. The operation of RF-SETs outside the superconducting gap has been a topic of study; the sub-gap operation, especially in the presence of large quantum fluctuations of quasiparticles remains largely unexplored, both theoretically and experimentally. We have investigated the effects of quantum fluctuations of quasiparticles on the operation of RF-SETs for large values of the quasiparticle cotunneling parameter alpha = 8EJ/Ec, where EJ and Ec are the Josephson and charging energies. We find that, for alpha > 1, sub-gap RF-SET operation is still feasible despite quantum fluctuations that wash out quasiparticle tunneling thresholds. Such RF-SETs show linearity and signal-to-noise ratio superior to those obtained when quantum fluctuations are weak, while still demonstrating excellent charge sensitivity. We have operated a QPC charge detector in a radio frequency mode that allows fast charge detection in a bandwidth of several megahertz. The noise limiting the sensitivity of the charge detector is not the noise of a secondary amplifier, but the non-equilibrium device noise of the QPC itself. The noise power averaged over a measurement bandwidth of about 10MHz around the carrier frequency is in agreement with the theory of photon-assisted shot noise. Frequency-resolved measurements, however show several significant discrepancies with the theoretical predictions. The measurement techniques developed can also be used to investigate the noise of other semiconductor nanostructures such as quantum dots in the Kondo regime. A study of the noise characteristics alone can not determine whether the device is operating at the quantum limit; a characterization of back action is also necessary. The inelastic current through a double quantum dot system (DQD) is sensitive to the spectral density of voltage fluctuations in its electromagnetic environment. Electrical transport studies on a DQD system electrostatically coupled to an SET shows qualitative evidence of back-action of SET. The design and fabrication of a few electron DQD device with integrated RF-SET and QPC charge sensors for the study of back action of the sensors and real-time electron dynamics in the DQD are also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selin, Victor; Ankner, John F.; Sukhishvili, Svetlana A.
Here in this paper, we report on the role of molecular diffusivity in the formation of nonlinearly growing polyelectrolyte multilayers (nlPEMs). Electrostatically bound polyelectrolyte multilayers were assembled from poly(methacrylic acid) (PMAA) as a polyanion and quaternized poly(2-(dimethylamino)ethyl methacrylate) (QPC) as a polycation. Film growth as measured by ellipsometry was strongly dependent on the time allowed for each polymer deposition step, suggesting that the diffusivities of the components are crucial in controlling the rate of film growth. Uptake of polyelectrolytes within nlPEMs was relatively slow and occurred on time scales ranging from minutes to hours, depending on the film thickness. Spectroscopicmore » ellipsometry measurements with nlPEM films exposed to aqueous solutions exhibited high (severalfold) degrees of film swelling and different swelling values for films exposed to QPC or PMAA solutions. FTIR spectroscopy showed that the average ionization of film-assembled PMAA increased upon binding of QPC and decreased upon binding of PMAA, in agreement with the charge regulation mechanism for weak polyelectrolytes. The use of neutron reflectometry (NR) enabled quantification of chain intermixing within the film, which was drastically enhanced when longer times were allowed for polyelectrolyte deposition. Diffusion coefficients of the polycation derived from the uptake rates of deuterated chains within hydrogenated films were of the order of 10 –14 cm 2/s, i.e., 5–6 orders of magnitude smaller than those found for diffusion of free polymer chains in solution. Exchange of the polymer solutions to buffer inhibited film intermixing. Taken together, these results contribute to understanding the mechanism of the growth of nonlinear polyelectrolyte multilayers and demonstrate the possibility of controlling film intermixing, which is highly desirable for potential future applications.« less
Nonlinear Layer-by-Layer Films: Effects of Chain Diffusivity on Film Structure and Swelling
Selin, Victor; Ankner, John F.; Sukhishvili, Svetlana A.
2017-08-09
Here in this paper, we report on the role of molecular diffusivity in the formation of nonlinearly growing polyelectrolyte multilayers (nlPEMs). Electrostatically bound polyelectrolyte multilayers were assembled from poly(methacrylic acid) (PMAA) as a polyanion and quaternized poly(2-(dimethylamino)ethyl methacrylate) (QPC) as a polycation. Film growth as measured by ellipsometry was strongly dependent on the time allowed for each polymer deposition step, suggesting that the diffusivities of the components are crucial in controlling the rate of film growth. Uptake of polyelectrolytes within nlPEMs was relatively slow and occurred on time scales ranging from minutes to hours, depending on the film thickness. Spectroscopicmore » ellipsometry measurements with nlPEM films exposed to aqueous solutions exhibited high (severalfold) degrees of film swelling and different swelling values for films exposed to QPC or PMAA solutions. FTIR spectroscopy showed that the average ionization of film-assembled PMAA increased upon binding of QPC and decreased upon binding of PMAA, in agreement with the charge regulation mechanism for weak polyelectrolytes. The use of neutron reflectometry (NR) enabled quantification of chain intermixing within the film, which was drastically enhanced when longer times were allowed for polyelectrolyte deposition. Diffusion coefficients of the polycation derived from the uptake rates of deuterated chains within hydrogenated films were of the order of 10 –14 cm 2/s, i.e., 5–6 orders of magnitude smaller than those found for diffusion of free polymer chains in solution. Exchange of the polymer solutions to buffer inhibited film intermixing. Taken together, these results contribute to understanding the mechanism of the growth of nonlinear polyelectrolyte multilayers and demonstrate the possibility of controlling film intermixing, which is highly desirable for potential future applications.« less
Observation of conductance doubling in an Andreev quantum point contact
NASA Astrophysics Data System (ADS)
Kjaergaard, M.; Nichele, F.; Suominen, H.; Nowak, M.; Wimmer, M.; Akhmerov, A.; Folk, J.; Flensberg, K.; Shabani, J.; Palmstrom, C.; Marcus, C.
One route to study the non-Abelian nature of excitations in topological superconductors is to realise gateable two dimensional (2D) semiconducting systems, with spin-orbit coupling in proximity to an s-wave superconductor. Previous work on coupling 2D electron gases (2DEG) with superconductors has been hindered by a non-ideal interface and unstable gateability. We report measurements on a gateable 2DEG coupled to superconductors through a pristine interface, and use aluminum grown in situ epitaxially on an InGaAs/InAs electron gas. We demonstrate quantization in units of 4e2 / h in a quantum point contact (QPC) in such hybrid systems. Operating the QPC as a tunnel probe, we observe a hard superconducting gap, overcoming the soft-gap problem in 2D superconductor/semiconductor systems. Our work paves way for a new and highly scalable system in which to pursue topological quantum information processing. Research supported by Microsoft Project Q and the Danish National Research Foundation.
Thermal averages in a quantum point contact with a single coherent wave packet.
Heller, E J; Aidala, K E; LeRoy, B J; Bleszynski, A C; Kalben, A; Westervelt, R M; Maranowski, K D; Gossard, A C
2005-07-01
A novel formal equivalence between thermal averages of coherent properties (e.g., conductance) and time averages of a single wave packet arises for Fermi gases and certain geometries. In the case of one open channel in a quantum point contact (QPC), only one wave packet history, with the wave packet width equal to the thermal length, completely determines the thermally averaged conductance. The formal equivalence moreover allows very simple physical interpretations of interference features surviving under thermal averaging. Simply put, pieces of the thermal wave packet returning to the QPC along independent paths must arrive at the same time in order to interfere. Remarkably, one immediate result of this approach is that higher temperature leads to narrower wave packets and therefore better resolution of events in the time domain. In effect, experiments at 4.2 K are performing time-gated experiments at better than a gigahertz. Experiments involving thermally averaged ballistic conductance in 2DEGS are presented as an application of this picture.
Kjaergaard, M; Nichele, F; Suominen, H J; Nowak, M P; Wimmer, M; Akhmerov, A R; Folk, J A; Flensberg, K; Shabani, J; Palmstrøm, C J; Marcus, C M
2016-09-29
Coupling a two-dimensional (2D) semiconductor heterostructure to a superconductor opens new research and technology opportunities, including fundamental problems in mesoscopic superconductivity, scalable superconducting electronics, and new topological states of matter. One route towards topological matter is by coupling a 2D electron gas with strong spin-orbit interaction to an s-wave superconductor. Previous efforts along these lines have been adversely affected by interface disorder and unstable gating. Here we show measurements on a gateable InGaAs/InAs 2DEG with patterned epitaxial Al, yielding devices with atomically pristine interfaces between semiconductor and superconductor. Using surface gates to form a quantum point contact (QPC), we find a hard superconducting gap in the tunnelling regime. When the QPC is in the open regime, we observe a first conductance plateau at 4e 2 /h, consistent with theory. The hard-gap semiconductor-superconductor system demonstrated here is amenable to top-down processing and provides a new avenue towards low-dissipation electronics and topological quantum systems.
NASA Astrophysics Data System (ADS)
Croke, Edward; Borselli, Matthew; Kiselev, Andrey; Deelman, Peter; Milosavljevic, Ivan; Alvarado-Rodriguez, Ivan; Ross, Richard; Schmitz, Adele; Gyure, Mark; Hunter, Andrew
2011-03-01
We report measurements of the spin-relaxation lifetime (T1) as a function of magnetic field in a strained-Si, accumulation-mode quantum dot. An integrated quantum-point contact (QPC) charge sensor was used to detect changes in dot occupancy as a function of bias applied to a single gate electrode. The addition spectra we obtained are consistent with theoretical predictions starting at N=0. The conductance of the charge sensor was measured by applying an AC voltage across the QPC and a 3 k Ω resistor. Lifetime measurements were conducted using a three-pulse technique consisting of a load, read, and flush sequence. T1 was measured by observing the decay of the spin bump amplitude as a function of the load pulse length. We measured decay times ranging from approximately 75 msec at 2T to 12 msec at 3T, consistent with previous reports and theoretical predictions. Sponsored by United States Department of Defense. Approved for Public Release, Distribution Unlimited.
Kjaergaard, M.; Nichele, F.; Suominen, H. J.; Nowak, M. P.; Wimmer, M.; Akhmerov, A. R.; Folk, J. A.; Flensberg, K.; Shabani, J.; Palmstrøm, C. J.; Marcus, C. M.
2016-01-01
Coupling a two-dimensional (2D) semiconductor heterostructure to a superconductor opens new research and technology opportunities, including fundamental problems in mesoscopic superconductivity, scalable superconducting electronics, and new topological states of matter. One route towards topological matter is by coupling a 2D electron gas with strong spin–orbit interaction to an s-wave superconductor. Previous efforts along these lines have been adversely affected by interface disorder and unstable gating. Here we show measurements on a gateable InGaAs/InAs 2DEG with patterned epitaxial Al, yielding devices with atomically pristine interfaces between semiconductor and superconductor. Using surface gates to form a quantum point contact (QPC), we find a hard superconducting gap in the tunnelling regime. When the QPC is in the open regime, we observe a first conductance plateau at 4e2/h, consistent with theory. The hard-gap semiconductor–superconductor system demonstrated here is amenable to top-down processing and provides a new avenue towards low-dissipation electronics and topological quantum systems. PMID:27682268
Vilcacundo, R; Barrio, D; Carpio, C; García-Ruiz, A; Rúales, J; Hernández-Ledesma, B; Carrillo, W
2017-09-01
Quinoa protein concentrate (QPC) was extracted and digested under in vitro gastrointestinal conditions. The protein content of QPC was in the range between 52.40 and 65.01% depending on the assay used. Quinoa proteins were almost completely hydrolyzed by pepsin at pH of 1.2, 2.0, and 3.2. At high pH, only partial hydrolysis was observed. During the duodenal phase, no intact proteins were visible, indicating their susceptibility to the in vitro simulated digestive conditions. Zebrafish larvae model was used to evaluate the in vivo ability of gastrointestinal digests to inhibit lipid peroxidation. Gastric digestion at pH 1.2 showed the highest lipid peroxidation inhibition percentage (75.15%). The lipid peroxidation activity increased after the duodenal phase. The digest obtained at the end of the digestive process showed an inhibition percentage of 82.10%, comparable to that showed when using BHT as positive control (87.13%).
[Quebec Pregnancy Cohort: prevalence of medication use during gestation and pregnancy outcomes].
Bérard, Anick; Sheehy, Odile
2014-01-01
Many women are exposed to medications during pregnancy. The Quebec Pregnancy Cohort (QPC) is a prospective population-based cohort which includes all data on pregnancies and children between January 1997 and December 2008. We linked four administrative databases in Quebec, Canada: RAMQ (medical and pharmaceutical), MED-ECHO (hospitalizations), ISQ (births/deaths), and MELS (Ministry of Education). Pregnancies included were covered by the Quebec prescription drug insurance plan (36% of women aged 15-45 years) from 12 months prior until the end of pregnancy. We analyzed 97,680 pregnancies. Prevalence of medication use was 74% pre-pregnancy, 56% during pregnancy, and 80% post-pregnancy. Most frequently used medications during pregnancy were antibiotics (47%), antiemetic drugs (23%), and non-steroïdal anti-inflammatory drugs (NSAIDs) [17%]. Medication users were more likely to have spontaneous abortions, preterm births, children with congenital malformations and postpartum depression than non-users (p<0.01). Medications are commonly used during pregnancy. The QPC is a powerful tool for perinatal pharmacoepidemiological research. © 2014 Société Française de Pharmacologie et de Thérapeutique.
NASA Astrophysics Data System (ADS)
Hong, Changki; Park, Jinhong; Chung, Yunchul; Choi, Hyungkook; Umansky, Vladimir
2017-11-01
Transmission through a quantum point contact (QPC) in the quantum Hall regime usually exhibits multiple resonances as a function of gate voltage and high nonlinearity in bias. Such behavior is unpredictable and changes sample by sample. Here, we report the observation of a sharp transition of the transmission through an open QPC at finite bias, which was observed consistently for all the tested QPCs. It is found that the bias dependence of the transition can be fitted to the Fermi-Dirac distribution function through universal scaling. The fitted temperature matches quite nicely to the electron temperature measured via shot-noise thermometry. While the origin of the transition is unclear, we propose a phenomenological model based on our experimental results that may help to understand such a sharp transition. Similar transitions are observed in the fractional quantum Hall regime, and it is found that the temperature of the system can be measured by rescaling the quasiparticle energy with the effective charge (e*=e /3 ). We believe that the observed phenomena can be exploited as a tool for measuring the electron temperature of the system and for studying the quasiparticle charges of the fractional quantum Hall states.
USDA-ARS?s Scientific Manuscript database
Seed dormancy has been associated with red grain color in cereal crops. The association was linked to the cluster of quantitative trait loci qSD7-1/qPC7 in weedy red rice. This research delimited the cluster to Os07g11020 or Rc encoding a predicted bHLH family transcription factor by intragenic reco...
ERIC Educational Resources Information Center
Seymour, Daniel
Based on a survey of Quality Management (QM) practitioners at 21 colleges, this study presents the 10 most difficult implementation hurdles to QM in higher education and a set of hurdle-clearing strategies. The hurdles are: (1) lack of time to implement QM; (2) perception that QM is something for janitorial and housing staffs but not applicable to…
The new technological solution for the JT-60SA quench protection circuits
NASA Astrophysics Data System (ADS)
Gaio, E.; Maistrello, A.; Novello, L.; Matsukawa, M.; Perna, M.; Ferro, A.; Yamauchi, K.; Piovan, R.
2018-07-01
An advanced technology has been developed and employed for the main circuit breakers (CB) of the quench protection circuits (QPC) of the superconducting coils of JT-60SA: it consists in a Hybrid mechanical-static CB (HCB) composed of a mechanical Bypass switch (BPS) for conducting the continuous current, in parallel to a static circuit breaker (SCB) based on integrated gate commutated thyristor (IGCT) for current interruption. It was the result of a R&D program carried out since 2006 to identify innovative solutions for the interruption of high dc current, able to improve the maintainability and availability of the CB. The HCB developed for the JT-60SA QPC is the first realization of a dc circuit breaker based on this design approach for interrupting current of some tens of kA with reapplied voltage of some kV. It also represents the first application of hybrid technology with IGCT for protection of superconducting magnets in fusion experiments. The paper aims at giving a comprehensive overview of the main R&D activities devoted to the development of this new technological approach; then, the key aspects of the design, manufacturing and testing of the QPCs for JT-60SA, successfully completed in Naka Site in summer 2015 are presented. Finally, the significance of this research is discussed and the possible future developments, in particular in view of DEMO fusion reactor, are outlined.
On the zero-bias anomaly and Kondo physics in quantum point contacts near pinch-off.
Xiang, S; Xiao, S; Fuji, K; Shibuya, K; Endo, T; Yumoto, N; Morimoto, T; Aoki, N; Bird, J P; Ochiai, Y
2014-03-26
We investigate the linear and non-linear conductance of quantum point contacts (QPCs), in the region near pinch-off where Kondo physics has previously been connected to the appearance of the 0.7 feature. In studies of seven different QPCs, fabricated in the same high-mobility GaAs/AlGaAs heterojunction, the linear conductance is widely found to show the presence of the 0.7 feature. The differential conductance, on the other hand, does not generally exhibit the zero-bias anomaly (ZBA) that has been proposed to indicate the Kondo effect. Indeed, even in the small subset of QPCs found to exhibit such an anomaly, the linear conductance does not always follow the universal temperature-dependent scaling behavior expected for the Kondo effect. Taken collectively, our observations demonstrate that, unlike the 0.7 feature, the ZBA is not a generic feature of low-temperature QPC conduction. We furthermore conclude that the mere observation of the ZBA alone is insufficient evidence for concluding that Kondo physics is active. While we do not rule out the possibility that the Kondo effect may occur in QPCs, our results appear to indicate that its observation requires a very strict set of conditions to be satisfied. This should be contrasted with the case of the 0.7 feature, which has been apparent since the earliest experimental investigations of QPC transport.
Quantum-ring spin interference device tuned by quantum point contacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diago-Cisneros, Leo; Mireles, Francisco
2013-11-21
We introduce a spin-interference device that comprises a quantum ring (QR) with three embedded quantum point contacts (QPCs) and study theoretically its spin transport properties in the presence of Rashba spin-orbit interaction. Two of the QPCs conform the lead-to-ring junctions while a third one is placed symmetrically in the upper arm of the QR. Using an appropriate scattering model for the QPCs and the S-matrix scattering approach, we analyze the role of the QPCs on the Aharonov-Bohm (AB) and Aharonov-Casher (AC) conductance oscillations of the QR-device. Exact formulas are obtained for the spin-resolved conductances of the QR-device as a functionmore » of the confinement of the QPCs and the AB/AC phases. Conditions for the appearance of resonances and anti-resonances in the spin-conductance are derived and discussed. We predict very distinctive variations of the QR-conductance oscillations not seen in previous QR proposals. In particular, we find that the interference pattern in the QR can be manipulated to a large extend by varying electrically the lead-to-ring topological parameters. The latter can be used to modulate the AB and AC phases by applying gate voltage only. We have shown also that the conductance oscillations exhibits a crossover to well-defined resonances as the lateral QPC confinement strength is increased, mapping the eigenenergies of the QR. In addition, unique features of the conductance arise by varying the aperture of the upper-arm QPC and the Rashba spin-orbit coupling. Our results may be of relevance for promising spin-orbitronics devices based on quantum interference mechanisms.« less
Non-Gaussianity in a quasiclassical electronic circuit
NASA Astrophysics Data System (ADS)
Suzuki, Takafumi J.; Hayakawa, Hisao
2017-05-01
We study the non-Gaussian dynamics of a quasiclassical electronic circuit coupled to a mesoscopic conductor. Non-Gaussian noise accompanying the nonequilibrium transport through the conductor significantly modifies the stationary probability density function (PDF) of the flux in the dissipative circuit. We incorporate weak quantum fluctuation of the dissipative LC circuit with a stochastic method and evaluate the quantum correction of the stationary PDF. Furthermore, an inverse formula to infer the statistical properties of the non-Gaussian noise from the stationary PDF is derived in the classical-quantum crossover regime. The quantum correction is indispensable to correctly estimate the microscopic transfer events in the QPC with the quasiclassical inverse formula.
Wong, Anthony F; Pielmeier, Ulrike; Haug, Peter J; Andreassen, Steen
2016-01-01
Objective Develop an efficient non-clinical method for identifying promising computer-based protocols for clinical study. An in silico comparison can provide information that informs the decision to proceed to a clinical trial. The authors compared two existing computer-based insulin infusion protocols: eProtocol-insulin from Utah, USA, and Glucosafe from Denmark. Materials and Methods The authors used eProtocol-insulin to manage intensive care unit (ICU) hyperglycemia with intravenous (IV) insulin from 2004 to 2010. Recommendations accepted by the bedside clinicians directly link the subsequent blood glucose values to eProtocol-insulin recommendations and provide a unique clinical database. The authors retrospectively compared in silico 18 984 eProtocol-insulin continuous IV insulin infusion rate recommendations from 408 ICU patients with those of Glucosafe, the candidate computer-based protocol. The subsequent blood glucose measurement value (low, on target, high) was used to identify if the insulin recommendation was too high, on target, or too low. Results Glucosafe consistently provided more favorable continuous IV insulin infusion rate recommendations than eProtocol-insulin for on target (64% of comparisons), low (80% of comparisons), or high (70% of comparisons) blood glucose. Aggregated eProtocol-insulin and Glucosafe continuous IV insulin infusion rates were clinically similar though statistically significantly different (Wilcoxon signed rank test P = .01). In contrast, when stratified by low, on target, or high subsequent blood glucose measurement, insulin infusion rates from eProtocol-insulin and Glucosafe were statistically significantly different (Wilcoxon signed rank test, P < .001), and clinically different. Discussion This in silico comparison appears to be an efficient nonclinical method for identifying promising computer-based protocols. Conclusion Preclinical in silico comparison analytical framework allows rapid and inexpensive identification of computer-based protocol care strategies that justify expensive and burdensome clinical trials. PMID:26228765
PACIFIC NORTHWEST SIDE-BY-SIDE PROTOCOL COMPARISON TEST
Eleven state, tribal, and federal agencies participated during summer 2005 in a side-by-side comparison of protocols used to measure common in-stream physical attributes to help determine which protocols are best for determining status and trend of stream/watershed condition. Th...
High-efficiency high-brightness diode lasers at 1470 nm/1550 nm for medical and defense applications
NASA Astrophysics Data System (ADS)
Gallup, Kendra; Ungar, Jeff; Vaissie, Laurent; Lammert, Rob; Hu, Wentao
2012-03-01
Diode lasers in the 1400 nm to 1600 nm regime are used in a variety of applications including pumping Er:YAG lasers, range finding, materials processing, aesthetic medical treatments and surgery. In addition to the compact size, efficiency, and low cost advantages of traditional diode lasers, high power semiconductor lasers in the eye-safe regime are becoming widely used in an effort to minimize the unintended impact of potentially hazardous scattered optical radiation from the laser source, the optical delivery system, or the target itself. In this article we describe the performance of high efficiency high brightness InP laser bars at 1470nm and 1550nm developed at QPC Lasers for applications ranging from surgery to rangefinding.
NASA Astrophysics Data System (ADS)
Xu, Ling; Zhao, Zhiwen
2017-08-01
A new quantum protocol with the assistance of a semi-honest third party (TP) is proposed, which allows the participants comparing the equality of their private information without disclosing them. Different from previous protocols, this protocol utilizes quantum key distribution against the collective-dephasing noise and the collective-rotation noise, which is more robust and abandons few samples, to transmit the classical information. In addition, this protocol utilizes the GHZ-like state and the χ + state to produce the entanglement swapping. And the Bell basis and the dual basis are used to measure the particle pair so that 3 bits of each participant's private information can be compared in each comparison time, which is more efficient and consumes fewer comparison times. Meanwhile, there is no need of unitary operation and hash function in this protocol. At the end, various kinds of outside attack and participant attack are discussed and analyzed to be invalid, so it can complete the comparison in security.
Brito, Maíra M; Lúcio, Cristina F; Angrimani, Daniel S R; Losano, João Diego A; Dalmazzo, Andressa; Nichi, Marcílio; Vannucchi, Camila I
2017-01-02
In addition to the existence of several cryopreservation protocols, no systematic research has been carried out in order to confirm the suitable protocol for canine sperm. This study aims to assess the effect of adding 5% glycerol during cryopreservation at 37°C (one-step) and 5°C (two-steps), in addition of testing two thawing protocols (37°C for 30 seconds, and 70°C for 8 seconds). We used 12 sperm samples divided into four experimental groups: Single-Step - Slow Thawing Group; Two-Step - Slow Thawing Group; Single-Step - Fast Thawing Group; and Two-Step - Fast Thawing Group. Frozen-thawed samples were submitted to automated analysis of sperm motility, evaluation of plasmatic membrane integrity, acrosomal integrity, mitochondrial activity, sperm morphology, sperm susceptibility to oxidative stress, and sperm binding assay to perivitellinic membrane of chicken egg yolk. Considering the comparison between freezing protocols, no statistical differences were verified for any of the response variables. When comparison between thawing protocols was performed, slow thawing protocol presented higher sperm count bound to perivitelline membrane of chicken egg yolk, compared to fast thawing protocol. Regardless of the freezing process, the slow thawing protocol can be recommended for the large scale cryopreservation of canine semen, since it shows a consistent better functional result.
Secure multiparty computation of a comparison problem.
Liu, Xin; Li, Shundong; Liu, Jian; Chen, Xiubo; Xu, Gang
2016-01-01
Private comparison is fundamental to secure multiparty computation. In this study, we propose novel protocols to privately determine [Formula: see text], or [Formula: see text] in one execution. First, a 0-1-vector encoding method is introduced to encode a number into a vector, and the Goldwasser-Micali encryption scheme is used to compare integers privately. Then, we propose a protocol by using a geometric method to compare rational numbers privately, and the protocol is information-theoretical secure. Using the simulation paradigm, we prove the privacy-preserving property of our protocols in the semi-honest model. The complexity analysis shows that our protocols are more efficient than previous solutions.
Tunable graphene quantum point contact transistor for DNA detection and characterization
Girdhar, Anuj; Sathe, Chaitanya; Schulten, Klaus; Leburton, Jean-Pierre
2015-01-01
A graphene membrane conductor containing a nanopore in a quantum point contact (QPC) geometry is a promising candidate to sense, and potentially sequence, DNA molecules translocating through the nanopore. Within this geometry, the shape, size, and position of the nanopore as well as the edge configuration influences the membrane conductance caused by the electrostatic interaction between the DNA nucleotides and the nanopore edge. It is shown that the graphene conductance variations resulting from DNA translocation can be enhanced by choosing a particular geometry as well as by modulating the graphene Fermi energy, which demonstrates the ability to detect conformational transformations of a double-stranded DNA, as well as the passage of individual base pairs of a single-stranded DNA molecule through the nanopore. PMID:25765702
Zhang, Jing; Moradi, Emilia; Somekh, Michael G; Mather, Melissa L
2018-01-15
A label-free microscopy method for assessing the differentiation status of stem cells is presented with potential application for characterization of therapeutic stem cell populations. The microscopy system is capable of characterizing live cells based on the use of evanescent wave microscopy and quantitative phase contrast (QPC) microscopy. The capability of the microscopy system is demonstrated by studying the differentiation of live immortalised neonatal mouse neural stem cells over a 15 day time course. Metrics extracted from microscope images are assessed and images compared with results from endpoint immuno-staining studies to illustrate the system's performance. Results demonstrate the potential of the microscopy system as a valuable tool for cell biologists to readily identify the differentiation status of unlabelled live cells.
Bires, Angela Macci; Lawson, Dori; Wasser, Thomas E; Raber-Baer, Donna
2013-12-01
Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.
Stimpfel, Martin; Vrtacnik-Bokal, Eda; Pozlep, Barbara; Virant-Klun, Irma
2015-01-01
The reports on how to stimulate the ovaries for oocyte retrieval in good prognosis patients are contradictory and often favor one type of controlled ovarian hyperstimulation (COH). For this reason, we retrospectively analyzed data from IVF/ICSI cycles carried out at our IVF Unit in good prognosis patients (aged <38 years, first and second attempts of IVF/ICSI, more than 3 oocytes retrieved) to elucidate which type of COH is optimal at our condition. The included patients were undergoing COH using GnRH agonist, GnRH antagonist or GnRH antagonist mild protocol in combination with gonadotrophins. We found significant differences in the average number of retrieved oocytes, immature oocytes, fertilized oocytes, embryos, transferred embryos, embryos frozen per cycle, and cycles with embryo freezing between studied COH protocols. Although there were no differences in live birth rate (LBR), miscarriages, and ectopic pregnancies between compared protocols, pregnancy rate was significantly higher in GnRH antagonist mild protocol in comparison with both GnRH antagonist and GnRH agonist protocols and cumulative LBR per cycle was significantly higher in GnRH antagonist mild protocol in comparison to GnRH agonist protocol. Our data show that GnRH antagonist mild protocol of COH could be the best method of choice in good prognosis patients.
Performance comparison of token ring protocols for hard-real-time communication
NASA Technical Reports Server (NTRS)
Kamat, Sanjay; Zhao, Wei
1992-01-01
The ability to guarantee the deadlines of synchronous messages while maintaining a good aggregate throughput is an important consideration in the design of distributed real-time systems. In this paper, we study two token ring protocols, the priority driven protocol and the timed token protocol, for their suitability for hard real-time systems. Both these protocols use a token to control access to the transmission medium. In a priority driven protocol, messages are assigned priorities and the protocol ensures that messages are transmitted in the order of their priorities. Timed token protocols do not provide for priority arbitration but ensure that the maximum access delay for a station is bounded. For both protocols, we first derive the schedulability conditions under which the transmission deadlines of a given set of synchronous messages can be guaranteed. Subsequently, we use these schedulability conditions to quantitatively compare the average case behavior of the protocols. This comparison demonstrates that each of the protocols has its domain of superior performance and neither dominates the other for the entire range of operating conditions.
[Is there still a future for the French "Perruche" jurisprudence?].
Manaouil, C; Jardé, O
2012-02-01
Since March 1, 2010, French citizens have a new procedure for defending their rights: the Priority preliminary ruling on the issue of constitutionality (QPC). During a trial, any citizen may request that the Constitutional Council be seized if he/she considers that a provision of a law applicable is inconsistent with the Constitution. One of the first QPCs was released regarding the Perruche antijurisprudence provision. The decision of the Supreme Court (Cour de Cassation) on November 17, 2000 had granted the child Nicolas Perruche the right to financial compensation for the material costs related to his physical disability as a result of congenital rubella. In response, Article 1 of the law of March 4, 2002 was passed in order to prohibit the compensation of a child "solely because of his/her birth". Since this law was enacted, only the moral injury of the parents can be indemnified in a case like that of Nicolas Perruche. Over time, the application of this article of the law of March 4, 2002 has become the subject of a heated debate. In the QPC decision of June 11, 2010, the Constitutional Council found the "Perruche antijurisprudence" provision to be consistent with the Constitution, except for the transitional provisions. Thus, it is assumed that the "Perruche antijurisprudence" provision applies to all children born after the entry into force of the law, i.e., as of March 7, 2002. In addition, the Perruche jurisprudence prevails for all claims filed before March 7, 2002. The issue of the cases for which legal action was taken after March 7, 2002 for a child born before March 7, 2002 remains debated. The current debate is whether the implementation of the law of March 4, 2002 should be extended or not to instances subsequent to March 7, 2002 for births prior to that date. In the present state of jurisprudence, the Court of Appeals answers negatively and applies the Perruche jurisprudence to all children born before March 7, 2002, regardless of the date by which the claims were filed. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uribe, Eva C; Sandoval, M Analisa; Sandoval, Marisa N
2009-01-01
With the 6 January 2009 entry into force of the Additional Protocol by the United States of America, all five declared Nuclear Weapon States that are part of the Nonproliferation Treaty have signed, ratified, and put into force the Additional Protocol. This paper makes a comparison of the strengths and weaknesses of the five Additional Protocols in force by the five Nuclear Weapon States with respect to the benefits to international nonproliferation aims. This paper also documents the added safeguards burden to the five declared Nuclear Weapon States that these Additional Protocols put on the states with respect to accessmore » to their civilian nuclear programs and the hosting of complementary access activities as part of the Additional Protocol.« less
NASA Astrophysics Data System (ADS)
Pan, Hong-Ming
2018-03-01
Recently, Jia et al. proposed the quantum private comparison protocol with the genuine four-particle entangled states (Jia et al., Int. J. Theor. Phys. 51(4), 1187-1194 (2012)). Jia et al. claimed that in this protocol, TP cannot obtain Alice and Bob's secrets and only knows their comparison result. However, in this paper, we demonstrate that if TP is a genuine semi-honest third party, he can totally obtain Alice and Bob's secrets by launching a particular intercept-resend-measure attack. After suggesting the intercept-resend-measure attack strategy from TP first, we put forward one corresponding improvement to prevent this attack.
Radio-frequency measurement in semiconductor quantum computation
NASA Astrophysics Data System (ADS)
Han, TianYi; Chen, MingBo; Cao, Gang; Li, HaiOu; Xiao, Ming; Guo, GuoPing
2017-05-01
Semiconductor quantum dots have attracted wide interest for the potential realization of quantum computation. To realize efficient quantum computation, fast manipulation and the corresponding readout are necessary. In the past few decades, considerable progress of quantum manipulation has been achieved experimentally. To meet the requirements of high-speed readout, radio-frequency (RF) measurement has been developed in recent years, such as RF-QPC (radio-frequency quantum point contact) and RF-DGS (radio-frequency dispersive gate sensor). Here we specifically demonstrate the principle of the radio-frequency reflectometry, then review the development and applications of RF measurement, which provides a feasible way to achieve high-bandwidth readout in quantum coherent control and also enriches the methods to study these artificial mesoscopic quantum systems. Finally, we prospect the future usage of radio-frequency reflectometry in scaling-up of the quantum computing models.
Jamaludin, Ummu K; M Suhaimi, Fatanah; Abdul Razak, Normy Norfiza; Md Ralib, Azrina; Mat Nor, Mohd Basri; Pretty, Christopher G; Humaidi, Luqman
2018-08-01
Blood glucose variability is common in healthcare and it is not related or influenced by diabetes mellitus. To minimise the risk of high blood glucose in critically ill patients, Stochastic Targeted Blood Glucose Control Protocol is used in intensive care unit at hospitals worldwide. Thus, this study focuses on the performance of stochastic modelling protocol in comparison to the current blood glucose management protocols in the Malaysian intensive care unit. Also, this study is to assess the effectiveness of Stochastic Targeted Blood Glucose Control Protocol when it is applied to a cohort of diabetic patients. Retrospective data from 210 patients were obtained from a general hospital in Malaysia from May 2014 until June 2015, where 123 patients were having comorbid diabetes mellitus. The comparison of blood glucose control protocol performance between both protocol simulations was conducted through blood glucose fitted with physiological modelling on top of virtual trial simulations, mean calculation of simulation error and several graphical comparisons using stochastic modelling. Stochastic Targeted Blood Glucose Control Protocol reduces hyperglycaemia by 16% in diabetic and 9% in nondiabetic cohorts. The protocol helps to control blood glucose level in the targeted range of 4.0-10.0 mmol/L for 71.8% in diabetic and 82.7% in nondiabetic cohorts, besides minimising the treatment hour up to 71 h for 123 diabetic patients and 39 h for 87 nondiabetic patients. It is concluded that Stochastic Targeted Blood Glucose Control Protocol is good in reducing hyperglycaemia as compared to the current blood glucose management protocol in the Malaysian intensive care unit. Hence, the current Malaysian intensive care unit protocols need to be modified to enhance their performance, especially in the integration of insulin and nutrition intervention in decreasing the hyperglycaemia incidences. Improvement in Stochastic Targeted Blood Glucose Control Protocol in terms of u en model is also a must to adapt with the diabetic cohort. Copyright © 2018 Elsevier B.V. All rights reserved.
Colyar, Jessica M; Eggett, Dennis L; Steele, Frost M; Dunn, Michael L; Ogden, Lynn V
2009-09-01
The relative sensitivity of side-by-side and sequential monadic consumer liking protocols was compared. In the side-by-side evaluation, all samples were presented at once and evaluated together 1 characteristic at a time. In the sequential monadic evaluation, 1 sample was presented and evaluated on all characteristics, then returned before panelists received and evaluated another sample. Evaluations were conducted on orange juice, frankfurters, canned chili, potato chips, and applesauce. Five commercial brands, having a broad quality range, were selected as samples for each product category to assure a wide array of consumer liking scores. Without their knowledge, panelists rated the same 5 retail brands by 1 protocol and then 3 wk later by the other protocol. For 3 of the products, both protocols yielded the same order of overall liking. Slight differences in order of overall liking for the other 2 products were not significant. Of the 50 pairwise overall liking comparisons, 44 were in agreement. The different results obtained by the 2 protocols in order of liking and significance of paired comparisons were due to the experimental variation and differences in sensitivity. Hedonic liking scores were subjected to statistical power analyses and used to calculate minimum number of panelists required to achieve varying degrees of sensitivity when using side-by-side and sequential monadic protocols. In most cases, the side-by-side protocol was more sensitive, thus providing the same information with fewer panelists. Side-by-side protocol was less sensitive in cases where sensory fatigue was a factor.
USDA-ARS?s Scientific Manuscript database
In the carbon market, greenhouse gas (GHG) offset protocols need to ensure that emission reductions are of high quality, quantifiable and real. However, lack of consistency across protocols for quantifying emission reductions compromise the credibility of offsets generated. Thus, protocol quantifica...
NASA Astrophysics Data System (ADS)
Zhao-Xu, Ji; Tian-Yu, Ye
2017-07-01
In this paper, a novel multi-party quantum private comparison protocol with a semi-honest third party (TP) is proposed based on the entanglement swapping of d-level cat states and d-level Bell states. Here, TP is allowed to misbehave on his own, but will not conspire with any party. In our protocol, n parties employ unitary operations to encode their private secrets and can compare the equality of their private secrets within one time execution of the protocol. Our protocol can withstand both the outside attacks and the participant attacks on the condition that none of the QKD methods is adopted to generate keys for security. One party cannot obtain other parties' secrets except for the case that their secrets are identical. The semi-honest TP cannot learn any information about these parties' secrets except the end comparison result on whether all private secrets from n parties are equal.
Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle
2017-10-01
To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Mechanical flip-chip for ultra-high electron mobility devices
Bennaceur, Keyan; Schmidt, Benjamin A.; Gaucher, Samuel; ...
2015-09-22
In this study, electrostatic gates are of paramount importance for the physics of devices based on high-mobility two-dimensional electron gas (2DEG) since they allow depletion of electrons in selected areas. This field-effect gating enables the fabrication of a wide range of devices such as, for example, quantum point contacts (QPC), electron interferometers and quantum dots. To fabricate these gates, processing is usually performed on the 2DEG material, which is in many cases detrimental to its electron mobility. Here we propose an alternative process which does not require any processing of the 2DEG material other than for the ohmic contacts. Thismore » approach relies on processing a separate wafer that is then mechanically mounted on the 2DEG material in a flip-chip fashion. This technique proved successful to fabricate quantum point contacts on both GaAs/AlGaAs materials with both moderate and ultra-high electron mobility.« less
Clinical Investigation Program Annual Progress Report
1993-09-30
272 93/200A 0 Comparison of Healing Rates of Bones Plated Following Fracture, Among Yucatan Swine Having Open and Closed Physes...Study Objective: Compare two enteral formulas in respect to nutritional aspects. (16) Technical Approach: Protocol will take place in SICU. (17...Protocol #: 93/200A (3) Status: Ongoing (4) Title: Comparison of Healing Rates of Bones Plated Following Fractures, Among Yucatan Swine Having Open and
Lopez-Rendon, Xochitl; Zhang, Guozhi; Coudyzer, Walter; Develter, Wim; Bosmans, Hilde; Zanca, Federica
2017-11-01
To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI vol of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI vol of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI vol values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. • The z-TCM information is sufficient for accurate dosimetry for standard protocols. • The z-TCM information is sufficient for accurate dosimetry for fast-speed scanning protocols. • For organ-based TCM schemes, the 3D-TCM information is necessary for accurate dosimetry. • At identical CTDI vol , the fast-speed scanning protocol delivered the highest doses. • Lung dose was higher in XCare than standard protocol at identical CTDI vol .
Kolesová, Hana; Čapek, Martin; Radochová, Barbora; Janáček, Jiří; Sedmera, David
2016-08-01
Our goal was to find an optimal tissue clearing protocol for whole-mount imaging of embryonic and adult hearts and whole embryos of transgenic mice that would preserve green fluorescent protein GFP fluorescence and permit comparison of different currently available 3D imaging modalities. We tested various published organic solvent- or water-based clearing protocols intended to preserve GFP fluorescence in central nervous system: tetrahydrofuran dehydration and dibenzylether protocol (DBE), SCALE, CLARITY, and CUBIC and evaluated their ability to render hearts and whole embryos transparent. DBE clearing protocol did not preserve GFP fluorescence; in addition, DBE caused considerable tissue-shrinking artifacts compared to the gold standard BABB protocol. The CLARITY method considerably improved tissue transparency at later stages, but also decreased GFP fluorescence intensity. The SCALE clearing resulted in sufficient tissue transparency up to ED12.5; at later stages the useful depth of imaging was limited by tissue light scattering. The best method for the cardiac specimens proved to be the CUBIC protocol, which preserved GFP fluorescence well, and cleared the specimens sufficiently even at the adult stages. In addition, CUBIC decolorized the blood and myocardium by removing tissue iron. Good 3D renderings of whole fetal hearts and embryos were obtained with optical projection tomography and selective plane illumination microscopy, although at resolutions lower than with a confocal microscope. Comparison of five tissue clearing protocols and three imaging methods for study of GFP mouse embryos and hearts shows that the optimal method depends on stage and level of detail required.
Ferraz Gonçalves, José António; Almeida, Ana; Costa, Isabel; Silva, Paula; Carneiro, Rui
2016-12-01
Agitation is a very distressing problem that must be controlled as quickly as possible, but using a safe method. The authors conducted a comparison of two protocols: a combination of haloperidol and midazolam and haloperidol alone. The combination drug protocol controlled 101 out of 121 (84%) episodes of agitation with only the first dose, whereas the haloperidol alone protocol controlled 47 out of 74 (64%) episodes. This difference is statistically significant (P =.002), with a post hoc analyzed power of 0.88. The median time from the first dose to the control of agitation was 15 minutes (range: 5-210) with the combination and 60 minutes (range: 10-430) with the other protocol, P <.001. There were no complications other than some transient somnolence, mainly with the combination protocol. The authors conclude that the combination of haloperidol and midazolam is effective and safe for the control of agitation in palliative care and it is more effective than haloperidol alone. Therefore, the combination should be adopted as the preferred protocol. It would be helpful if the usefulness of this protocol is confirmed by others.
A Comparison of Inquiry and Worked Example Web-Based Instruction Using Physlets
ERIC Educational Resources Information Center
Lee, Kevin M.; Nicoll, Gayle; Brooks, David W.
2004-01-01
This paper compares two protocols for web-based instruction using simulations in an introductory physics class. The Inquiry protocol allowed students to control input parameters while the Worked Example protocol did not. Students in the Worked Example group performed significantly higher on a common assessment. The ramifications of this study are…
Quantum Private Comparison of Equality Based on Five-Particle Cluster State
NASA Astrophysics Data System (ADS)
Chang, Yan; Zhang, Wen-Bo; Zhang, Shi-Bin; Wang, Hai-Chun; Yan, Li-Li; Han, Gui-Hua; Sheng, Zhi-Wei; Huang, Yuan-Yuan; Suo, Wang; Xiong, Jin-Xin
2016-12-01
A protocol for quantum private comparison of equality (QPCE) is proposed based on five-particle cluster state with the help of a semi-honest third party (TP). In our protocol, TP is allowed to misbehave on its own but can not conspire with either of two parties. Compared with most two-user QPCE protocols, our protocol not only can compare two groups of private information (each group has two users) in one execution, but also compare just two private information. Compared with the multi-user QPCE protocol proposed, our protocol is safer with more reasonable assumptions of TP. The qubit efficiency is computed and analyzed. Our protocol can also be generalized to the case of 2N participants with one TP. The 2N-participant protocol can compare two groups (each group has N private information) in one execution or just N private information. Supported by NSFC under Grant Nos. 61402058, 61572086, the Fund for Middle and Young Academic Leaders of CUIT under Grant No. J201511, the Science and Technology Support Project of Sichuan Province of China under Grant No. 2013GZX0137, the Fund for Young Persons Project of Sichuan Province of China under Grant No. 12ZB017, and the Foundation of Cyberspace Security Key Laboratory of Sichuan Higher Education Institutions under Grant No. szjj2014-074
Cho, S H; Lowenstein, J R; Balter, P A; Wells, N H; Hanson, W F
2000-01-01
A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosimetry based on TG-51 may be somewhat different from those based on TG-21. The Radiological Physics Center has conducted a systematic comparison between the two protocols, in which photon and electron beam outputs following both protocols were compared under identical conditions. Cylindrical chambers used in this study were selected from the list given in the TG-51 report, covering the majority of current manufacturers. Measured ratios between absorbed-dose and air-kerma calibration factors, derived from the standards traceable to the NIST, were compared with calculated values using the TG-21 protocol. The comparison suggests that there is roughly a 1% discrepancy between measured and calculated ratios. This discrepancy may provide a reasonable measure of possible changes between the absorbed-dose to water determined by TG-51 and that determined by TG-21 for photon beam calibrations. The typical change in a 6 MV photon beam calibration following the implementation of the TG-51 protocol was about 1%, regardless of the chamber used, and the change was somewhat smaller for an 18 MV photon beam. On the other hand, the results for 9 and 16 MeV electron beams show larger changes up to 2%, perhaps because of the updated electron stopping power data used for the TG-51 protocol, in addition to the inherent 1% discrepancy presented in the calibration factors. The results also indicate that the changes may be dependent on the electron energy.
Dynamic sentinel lymph node biopsy for penile cancer: a comparison between 1- and 2-day protocols.
Dimopoulos, Panagiotis; Christopoulos, Panagiotis; Shilito, Sam; Gall, Zara; Murby, Brian; Ashworth, David; Taylor, Ben; Carrington, Bernadette; Shanks, Jonathan; Clarke, Noel; Ramani, Vijay; Parr, Nigel; Lau, Maurice; Sangar, Vijay
2016-06-01
To determine the outcome of clinically negative node (cN0) patients with penile cancer undergoing dynamic sentinel node biopsy (DSNB), comparing the results of a 1- and 2-day protocol that can be used as a minimal invasive procedure for staging of penile cancer. This is a retrospective analysis of 151 cN0 patients who underwent DSNB from 2008 to 2013 for newly diagnosed penile cancer. Data were analysed per groin and separated into groups according to the protocol followed. The comparison of the two protocols involved the number of nodes excised, γ-counts, false-negative rates (FNR), and complication rates (Clavien-Dindo grading system). In all, 280 groins from 151 patients underwent DSNB after a negative ultrasound ± fine-needle aspiration cytology. The 1-day protocol was performed in 65 groins and the 2-day protocol in 215. Statistically significantly more nodes were harvested with the 1-day protocol (1.92/groin) compared with the 2-day protocol (1.60/groin). The FNRs were 0%, 6.8% and 5.1%, for the 1-day protocol, 2-day protocol, and overall, respectively. Morbidity of the DSNB was 21.4% for all groins, and 26.2% and 20.1% for the 1-day and 2-day protocols, respectively. Most of the complications were of Clavien-Dindo Grade 1-2. DSNB is safe for staging patients with penile cancer. There is a trend towards a 1-day protocol having a lower FNR than a 2-day protocol, albeit at the expense of a slightly higher complication rate. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.
Comparison of test protocols for standard room/corner tests
R. H. White; M. A. Dietenberger; H. Tran; O. Grexa; L. Richardson; K. Sumathipala; M. Janssens
1998-01-01
As part of international efforts to evaluate alternative reaction-to-fire tests, several series of room/comer tests have been conducted. This paper reviews the overall results of related projects in which different test protocols for standard room/corner tests were used. Differences in the test protocols involved two options for the ignition burner scenario and whether...
Thermogravimetric Analysis of Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Arepalli, Sivram; Nikolaev, Pavel; Gorelik, Olga
2010-01-01
An improved protocol for thermogravimetric analysis (TGA) of samples of single-wall carbon nanotube (SWCNT) material has been developed to increase the degree of consistency among results so that meaningful comparisons can be made among different samples. This improved TGA protocol is suitable for incorporation into the protocol for characterization of carbon nanotube material. In most cases, TGA of carbon nanotube materials is performed in gas mixtures that contain oxygen at various concentrations. The improved protocol is summarized.
Marienau, Karen J; Cramer, Elaine H; Coleman, Margaret S; Marano, Nina; Cetron, Martin S
2014-01-01
In-flight transmission risk of Mycobacterium tuberculosis is not well defined, although studies suggest it is low. The impact of flight-related tuberculosis (TB) contact investigations (TBCIs) on TB prevention and control is not well established, and they compete for resources with activities with established benefits. We sought to determine the risks and cost-benefits of using more restrictive criteria in comparison to the Centers for Disease Control and Prevention (CDC) 2008 protocol for TBCIs. The risk-benefits of a modified CDC protocol were analyzed in comparison to the 2008 CDC protocol using data from flight-related TBCIs conducted in the United States from 2007 through 2009. We predicted the numbers and characteristics of case-travelers that would be identified using each protocol's criteria, and results of the associated passenger-contacts' TB screening tests. The economic analysis compared the costs of TBCIs to avoided costs of TB treatment and mortality using a Return on Investment model. The estimated in-flight transmission risk using a modified CDC protocol was 1.4%-19% versus 1.1%-24% for the 2008 protocol. Numbers of TBCIs and immediate costs to health departments were reduced by half. Long-term cost-benefits were comparable. CDC's modified protocol appears to be a feasible alternative that will conserve public health resources without jeopardizing the public's health. Published by Elsevier Ltd.
Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.
Henríquez, Francisco Cutanda
2009-01-01
Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS‐398 and AAPM TG‐51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison has been carried out for photon beams of nominal energies: 4 MV, 6 MV, 8 MV, 10 MV and 18 MV. An NE 2571 graphite ionization chamber was used in this study, cross‐calibrated against an NE 2611A Secondary Standard, calibrated in the National Physical Laboratory (NPL). Absolute dose in reference conditions was obtained using each of these three protocols including: beam quality indices, beam quality conversion factors both theoretical and NPL experimental ones, correction factors for influence quantities and absolute dose measurements. Each protocol recommendations have been strictly followed. Uncertainties have been obtained according to the ISO Guide to the Expression of Uncertainty in Measurement. Absorbed dose obtained according to all three protocols agree within experimental uncertainty. The largest difference between absolute dose results for two protocols is obtained for the highest energy: 0.7% between IPSM 1990 and IAEA TRS‐398 using theoretical beam quality conversion factors. PACS number: 87.55.tm
A comparison of protocols and observer precision for measuring physical stream attributes
Whitacre, H.W.; Roper, B.B.; Kershner, J.L.
2007-01-01
Stream monitoring programs commonly measure physical attributes to assess the effect of land management on stream habitat. Variability associated with the measurement of these attributes has been linked to a number of factors, but few studies have evaluated variability due to differences in protocols. We compared six protocols, five used by the U.S. Department of Agriculture Forest Service and one by the U.S. Environmental Protection Agency, on six streams in Oregon and Idaho to determine whether differences in protocol affect values for 10 physical stream attributes. Results from Oregon and Idaho were combined for groups participating in both states, with significant differences in attribute means for 9 out of the 10 stream attributes. Significant differences occurred in 5 of 10 in Idaho, and 10 of 10 in Oregon. Coefficients of variation, signal-to-noise ratio, and root mean square error were used to evaluate measurement precision. There were differences among protocols for all attributes when states were analyzed separately and as a combined dataset. Measurement differences were influenced by choice of instruments, measurement method, measurement location, attribute definitions, and training approach. Comparison of data gathered by observers using different protocols will be difficult unless a core set of protocols for commonly measured stream attributes can be standardized among monitoring programs.
NASA Astrophysics Data System (ADS)
Jiang, Dong-Huan; Xu, Guang-Bao
2018-07-01
Based on locally indistinguishable orthogonal product states, we propose a novel multiparty quantum key agreement (QKA) protocol. In this protocol, the private key information of each party is encoded as some orthogonal product states that cannot be perfectly distinguished by local operations and classical communications. To ensure the security of the protocol with small amount of decoy particles, the different particles of each product state are transmitted separately. This protocol not only can make each participant fairly negotiate a shared key, but also can avoid information leakage in the maximum extent. We give a detailed security proof of this protocol. From comparison result with the existing QKA protocols, we can know that the new protocol is more efficient.
Weidner, Christopher; Steinfath, Matthias; Wistorf, Elisa; Oelgeschläger, Michael; Schneider, Marlon R; Schönfelder, Gilbert
2017-08-16
Recent studies that compared transcriptomic datasets of human diseases with datasets from mouse models using traditional gene-to-gene comparison techniques resulted in contradictory conclusions regarding the relevance of animal models for translational research. A major reason for the discrepancies between different gene expression analyses is the arbitrary filtering of differentially expressed genes. Furthermore, the comparison of single genes between different species and platforms often is limited by technical variance, leading to misinterpretation of the con/discordance between data from human and animal models. Thus, standardized approaches for systematic data analysis are needed. To overcome subjective gene filtering and ineffective gene-to-gene comparisons, we recently demonstrated that gene set enrichment analysis (GSEA) has the potential to avoid these problems. Therefore, we developed a standardized protocol for the use of GSEA to distinguish between appropriate and inappropriate animal models for translational research. This protocol is not suitable to predict how to design new model systems a-priori, as it requires existing experimental omics data. However, the protocol describes how to interpret existing data in a standardized manner in order to select the most suitable animal model, thus avoiding unnecessary animal experiments and misleading translational studies.
NASA Technical Reports Server (NTRS)
Wagner, Raymond S.; Barton, Richard J.
2011-01-01
Standards-based wireless sensor network (WSN) protocols are promising candidates for spacecraft avionics systems, offering unprecedented instrumentation flexibility and expandability. Ensuring reliable data transport is key, however, when migrating from wired to wireless data gathering systems. In this paper, we conduct a rigorous laboratory analysis of the relative performances of the ZigBee Pro and ISA100.11a protocols in a representative crewed aerospace environment. Since both operate in the 2.4 GHz radio frequency (RF) band shared by systems such as Wi-Fi, they are subject at times to potentially debilitating RF interference. We compare goodput (application-level throughput) achievable by both under varying levels of 802.11g Wi-Fi traffic. We conclude that while the simpler, more inexpensive ZigBee Pro protocol performs well under moderate levels of interference, the more complex and costly ISA100.11a protocol is needed to ensure reliable data delivery under heavier interference. This paper represents the first published, rigorous analysis of WSN protocols in an aerospace environment that we are aware of and the first published head-to-head comparison of ZigBee Pro and ISA100.11a.
Engelhardt, Othmar G.; Wood, John; Heath, Alan; Katz, Jacqueline M.; Peiris, Malik; Hoschler, Katja; Hungnes, Olav; Zhang, Wenqing; Van Kerkhove, Maria D.
2015-01-01
The microneutralization assay is commonly used to detect antibodies to influenza virus, and multiple protocols are used worldwide. These protocols differ in the incubation time of the assay as well as in the order of specific steps, and even within protocols there are often further adjustments in individual laboratories. The impact these protocol variations have on influenza serology data is unclear. Thus, a laboratory comparison of the 2-day enzyme-linked immunosorbent assay (ELISA) and 3-day hemagglutination (HA) microneutralization (MN) protocols, using A(H1N1)pdm09, A(H3N2), and A(H5N1) viruses, was performed by the CONSISE Laboratory Working Group. Individual laboratories performed both assay protocols, on multiple occasions, using different serum panels. Thirteen laboratories from around the world participated. Within each laboratory, serum sample titers for the different assay protocols were compared between assays to determine the sensitivity of each assay and were compared between replicates to assess the reproducibility of each protocol for each laboratory. There was good correlation of the results obtained using the two assay protocols in most laboratories, indicating that these assays may be interchangeable for detecting antibodies to the influenza A viruses included in this study. Importantly, participating laboratories have aligned their methodologies to the CONSISE consensus 2-day ELISA and 3-day HA MN assay protocols to enable better correlation of these assays in the future. PMID:26108286
COMPARISON OF USEPA FIELD SAMPLING METHODS FOR BENTHIC MACROINVERTEBRATE STUDIES
Two U.S. Environmental Protection Agency (USEPA) macroinvertebrate sampling protocols were compared in the Mid-Atlantic Highlands region. The Environmental Monitoring and Assessment Program (EMAP) wadeable streams protocol results in a single composite sample from nine transects...
Proposed test protocol for video imaging detection at intersection stop lines.
DOT National Transportation Integrated Search
2010-08-01
Test protocols for non-loop detectors have often required comparing the performance : attributes of these detectors with those of loops or other point detectors, or to manual counts. : However, that comparison is not always appropriate for a variety ...
Thomas V. Dietsch
2005-01-01
This study presents a protocol developed to rapidly assess ectoparasite prevalence and intensity. Using this protocol during a mist-netting project in two different coffee agroecosystems in Chiapas, Mexico, data were collected on ectoparasitic chigger mite larvae (Acarina: Trombiculidae) found on resident and migratory birds. Surprisingly high infestation rates were...
ERIC Educational Resources Information Center
Paez-Blarrina, Marisa; Luciano, Carmen; Gutierrez-Martinez, Olga; Valdivia, Sonsoles; Rodriguez-Valverde, Miguel; Ortega, Jose
2008-01-01
This study compares the effect of an acceptance-based protocol (ACT) and a cognitive control-based (CONT) protocol on three measures of pain coping: tolerance, self-report, and believability. Specific methodological controls were employed to further isolate the role of the value of participating in a pain task, compared to previous investigations…
Anaemia management protocols in the care of haemodialysis patients: examining patient outcomes.
Saunders, Sushila; MacLeod, Martha L P; Salyers, Vince; MacMillan, Peter D; Ogborn, Malcolm R
2013-08-01
To determine whether the use of a nurse-driven protocol in the haemodialysis setting is as safe and effective as traditional physician-driven approaches to anaemia management. The role of haemodialysis nurses in renal anaemia management has evolved through the implementation of nurse-driven protocols, addressing the trend of exceeding haemoglobin targets and rising costs of erythropoietin-stimulating agents. Retrospective, non-equivalent case control group design. The sample was from three haemodialysis units in a control group (n = 64) and three haemodialysis units in a protocol group (n = 43). The protocol group used a nurse-driven renal anaemia management protocol, while the control group used a traditional physician-driven approach to renal anaemia management. All retrospective data were obtained from a provincial renal database. Data were analysed using chi-square tests and t-tests. Patient outcomes examined were haemoglobin levels, transferrin saturation levels, erythropoietin-stimulating agents use and intravenous iron use. Cost comparisons were determined using average use of erythropoietin-stimulating agents and intravenous iron. Control and protocol groups reached haemoglobin target levels. In the protocol group, 75% reached transferrin saturation target levels in comparison with 25% of the control group. Use and costs for iron was higher in the control group, while use and costs for erythropoietin was higher in the protocol group. The higher usage of erythropoietin-stimulating agents was potentially related to comorbid conditions amongst the protocol group. A nurse-driven protocol approach to renal anaemia management was as effective as the physician-driven approach in reaching haemoglobin and transferrin saturation levels. Further examination of the use and dosing of erythropoietin-stimulating agents and intravenous iron, their impact on haemoglobin levels related to patient comorbidities and subsequent cost effectiveness of protocols is required. Using a nurse-driven protocol in practice supports the independent nursing role while contributing to safe patient outcomes. © 2013 Blackwell Publishing Ltd.
Comparison of EPA Method 1615 RT-qPCR Assays in Standard and Kit Format
EPA Method 1615 contains protocols for measuring enterovirus and norovirus by reverse transcription quantitative polymerase chain reaction. A commercial kit based upon these protocols was designed and compared to the method's standard approach. Reagent grade, secondary effluent, ...
Distance-Based and Low Energy Adaptive Clustering Protocol for Wireless Sensor Networks
Gani, Abdullah; Anisi, Mohammad Hossein; Ab Hamid, Siti Hafizah; Akhunzada, Adnan; Khan, Muhammad Khurram
2016-01-01
A wireless sensor network (WSN) comprises small sensor nodes with limited energy capabilities. The power constraints of WSNs necessitate efficient energy utilization to extend the overall network lifetime of these networks. We propose a distance-based and low-energy adaptive clustering (DISCPLN) protocol to streamline the green issue of efficient energy utilization in WSNs. We also enhance our proposed protocol into the multi-hop-DISCPLN protocol to increase the lifetime of the network in terms of high throughput with minimum delay time and packet loss. We also propose the mobile-DISCPLN protocol to maintain the stability of the network. The modelling and comparison of these protocols with their corresponding benchmarks exhibit promising results. PMID:27658194
Selmic, L E; Burton, J H; Thamm, D H; Withrow, S J; Lana, S E
2014-01-01
Many chemotherapy protocols have been reported for treatment of canine appendicular osteosarcoma (OSA), but outcome comparisons in a single population are lacking. To evaluate the effects of protocol and dose intensity (DI) on treatment outcomes for carboplatin and doxorubicin-based chemotherapy protocols. Four hundred and seventy dogs with appendicular OSA. A retrospective cohort study was performed comprising consecutive dogs treated (1997-2012) with amputation followed by 1 of 5 chemotherapy protocols: carboplatin 300 mg/m(2) IV q21d for 4 or 6 cycles (CARBO6), doxorubicin 30 mg/m(2) IV q14d or q21d for 5 cycles, and alternating carboplatin 300 mg/m(2) IV and doxorubicin 30 mg/m(2) IV q21d for 3 cycles. Adverse events (AE) and DI were evaluated. Kaplan-Meier survival curves and Cox proportional hazards regression were used to compare disease-free interval (DFI) and survival time (ST) among protocols. The overall median DFI and ST were 291 days and 284 days, respectively. A lower proportion of dogs prescribed CARBO6 experienced AEs compared to other protocols (48.4% versus 60.8-75.8%; P = .001). DI was not associated with development of metastases or death. After adjustment for baseline characteristics and prognostic factors, none of the protocols provided a significant reduction in risk of development of metastases or death. Although choice of protocol did not result in significant differences in DFI or ST, the CARBO6 protocol resulted in a lower proportion of dogs experiencing AEs, which could be advantageous in maintaining high quality of life during treatment. DI was not a prognostic indicator in this study. Copyright © 2014 by the American College of Veterinary Internal Medicine.
A kind of universal quantum secret sharing protocol
NASA Astrophysics Data System (ADS)
Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian
2017-01-01
Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.
A kind of universal quantum secret sharing protocol.
Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian
2017-01-12
Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix.
A kind of universal quantum secret sharing protocol
Chen, Xiu-Bo; Dou, Zhao; Xu, Gang; He, Xiao-Yu; Yang, Yi-Xian
2017-01-01
Universality is an important feature, but less researched in quantum communication protocols. In this paper, a kind of universal quantum secret sharing protocol is investigated. Firstly, we design a quantum secret sharing protocol based on the Borras-Plastino-Batle (BPB) state. Departing from previous research, our protocol has a salient feature in that participants in our protocol only need projective measurement instead of any unitary operations. It makes our protocol more flexible. Secondly, universality of quantum communication protocols is studied for the first time. More specifically, module division of quantum communication protocols and coupling between different modules are discussed. Our aforementioned protocol is analyzed as an example. On one hand, plenty of quantum states (the BPB-class states and the BPB-like-class states, which are proposed in this paper) could be used as carrier to perform our protocol. On the other hand, our protocol also could be regarded as a quantum private comparison protocol with a little revision. These features are rare for quantum communication protocols, and make our protocol more robust. Thirdly, entanglements of the BPB-class states are calculated in the Appendix. PMID:28079109
2010-01-01
Background Surveys from the USA, Australia and Spain have shown significant inter-institutional variation in delivery room (DR) management of very low birth weight infants (VLBWI, < 1500 g) at birth, despite regularly updated international guidelines. Objective To investigate protocols for DR management of VLBWI in Germany, Austria and Switzerland and to compare these with the 2005 ILCOR guidelines. Methods DR management protocols were surveyed in a prospective, questionnaire-based survey in 2008. Results were compared between countries and between academic and non-academic units. Protocols were compared to the 2005 ILCOR guidelines. Results In total, 190/249 units (76%) replied. Protocols for DR management existed in 94% of units. Statistically significant differences between countries were found regarding provision of 24 hr in house neonatal service; presence of a designated resuscitation area; devices for respiratory support; use of pressure-controlled manual ventilation devices; volume control by respirator; and dosage of Surfactant. There were no statistically significant differences regarding application and monitoring of supplementary oxygen, or targeted saturation levels, or for the use of sustained inflations. Comparison of academic and non-academic hospitals showed no significant differences, apart from the targeted saturation levels (SpO2) at 10 min. of life. Comparison with ILCOR guidelines showed good adherence to the 2005 recommendations. Summary Delivery room management in German, Austrian and Swiss neonatal units was commonly based on written protocols. Only minor differences were found regarding the DR setup, devices used and the targeted ranges for SpO2 and FiO2. DR management was in good accordance with 2005 ILCOR guidelines, some units already incorporated evidence beyond the ILCOR statement into their routine practice. PMID:21159574
Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee
2012-01-01
To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.
Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P
2010-08-17
We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.
Multicasting in Wireless Communications (Ad-Hoc Networks): Comparison against a Tree-Based Approach
NASA Astrophysics Data System (ADS)
Rizos, G. E.; Vasiliadis, D. C.
2007-12-01
We examine on-demand multicasting in ad hoc networks. The Core Assisted Mesh Protocol (CAMP) is a well-known protocol for multicast routing in ad-hoc networks, generalizing the notion of core-based trees employed for internet multicasting into multicast meshes that have much richer connectivity than trees. On the other hand, wireless tree-based multicast routing protocols use much simpler structures for determining route paths, using only parent-child relationships. In this work, we compare the performance of the CAMP protocol against the performance of wireless tree-based multicast routing protocols, in terms of two important factors, namely packet delay and ratio of dropped packets.
Student Performances in Various Learning Protocols
ERIC Educational Resources Information Center
Gregorius, Roberto
2011-01-01
A comparison was made between students' overall performance, as measured by overall grade, in different teaching and learning protocols: (1) traditional textbook and lecture along with standard examinations; (2) lectures with online augmentation and PowerPoint lecture notes along with standard examinations; (3) similar to "(2)" but with…
The development, verification, and comparison study between LC-MS libraries for two manufacturers’ instruments and a verified protocol are discussed. The LC-MS library protocol was verified through an inter-laboratory study that involved Federal, State, and private laboratories. ...
Glodkowska, Eliza; Bialas, Agnieszka; Jackowska, Teresa
2007-01-01
Acute lymphoblastic leukaemia (ALL) is one of the most common cancers in children. In Poland, since November 2002 a new protocol of risk stratification has been recommended for assessment of risk factors and for choosing therapy regimens. assessment of accuracy of protocol ALL-IC 2002 in comparison to previously used risk stratification protocols. ALL was diagnosed in 100 children (44 girls, 56 boys; 1-18 years of age) in the Department of Pediatric Hematology and Oncology, Warsaw Medical University, over the period from November 2002 to November 2006. According to the ALL-IC 2002 protocol the patients were divided into three risk groups: SR-standard, IR-intermediate and HR-high. The stratification was by age, leukocyte count, cytogenetic changes, early response to prednisone therapy and bone marrow remission. In the previously used risk stratification protocols-BFM-90, only hepatosplenomegaly and the number of blasts in peripheral blood (PB) were considered, and the patients were divided into three risk groups: low (LRG<0.8), medium (MRG) and high (HRG>1.2). out of the 100 patients qualified for treatment regimens according to the ALL-IC 2002 protocol, 97 entered remission, 11 died and 3 had a relapse. Under the ALL-IC 2002 protocol these children were stratified into the following groups: SR-31%, IR-44% and HR-25%. In the previously used stratification, there would be 26% children in low, 46% in the medium and 28% in the high risk group. According to the BFM-90 protocol 18/31 (58%) and 16/44 (36%) patients from the SR and IR groups respectively would be given more intensive treatment. On the other hand 11/44 (25%) and 14/25 (56%) patients from the IR and HR groups respectively would be given less intensive treatment. 1. ALL-IC 2002 protocol in comparison with the previously used protocol BFM-90, changes the qualification of children with ALL for the SR, IR and HR risk groups. This is linked to basic change of treatment protocol, adequate to severity of disease. 2. Children with ALL qualified according to protocol BFM-90 for moderate risk group (IR) constitute a mixed group in the ALL-IC 2002 classification. Part of the children was moved to the standard risk group (SR), part to high risk group (HR), and the rest remains in the intermediate risk category (IR). 3. Further studies are needed on stratification validity according to ALL-IL 2002 and on the need of further modification (eg assessment of additional factors) in order to decide on the best treatment, adequate to severity of disease.
The effect of relational training on intelligence quotient: a case study.
Vizcaíno-Torres, Rosa M; Ruiz, Francisco J; Luciano, Carmen; López-López, Juan C; Barbero-Rubio, Adrián; Gil, Enriquel
2015-01-01
Relational training protocols based on Relational Frame Theory (RFT) are showing promising results in increasing intelligence quotient. This case study aimed at analyzing the effect of a training protocol in fluency and flexibility in relational responding on intelligence quotient with a 4-year-old child. The child’s cognitive and psychomotor development was evaluated before and after the implementation of the training protocol using the McCarthy’s Aptitudes and Psychomotricity Scale (MSCA). The training protocol consisted of a multiple-exemplar-training (MET) in relational framing in accordance with COORDINATION (Phases 1 and 2), OPPOSITION (Phase 3 and 4), and COMPARISON (Phases 5 and 6). The MET protocol was implemented in approximately 12 hours throughout five and one half months. The training was effective in establishing relational responding in OPPOSITION and COMPARISON frames as well as in promoting fluency and flexibility in all the three types of trained relations. After this training, the child showed an increase above 1.5 SD in the General Cognitive Index of the MSCA (from 106 to 131). This case study adds further empirical evidence of the potential of RFT training to improve cognitive abilities and intelligence.
Vignion-Dewalle, Anne-Sophie; Baert, Gregory; Devos, Laura; Thecua, Elise; Vicentini, Claire; Mortier, Laurent; Mordon, Serge
2017-09-01
Photodynamic therapy (PDT) is an emerging treatment modality for various diseases, especially for dermatological conditions. Although, the standard PDT protocol for the treatment of actinic keratoses in Europe has shown to be effective, treatment-associated pain is often observed in patients. Different modifications to this protocol attempted to decrease pain have been investigated. The decrease in fluence rate seems to be a promising solution. Moreover, it has been suggested that light fractionation significantly increases the efficacy of PDT. Based on a flexible light-emitting textile, the FLEXITHERALIGHT device specifically provides a fractionated illumination at a fluence rate more than six times lower than that of the standard protocol. In a recently completed clinical trial of PDT for the treatment of actinic keratosis, the non-inferiority of a protocol involving illumination with the FLEXITHERALIGHT device after a short incubation time and referred to as the FLEXITHERALIGHT protocol has been assessed compared to the standard protocol. In this paper, we propose a comparison of the two above mentioned 635 nm red light protocols with 37 J/cm 2 in the PDT treatment of actinic keratosis: the standard protocol and the FLEXITHERALIGHT one through a mathematical modeling. This mathematical modeling, which slightly differs from the one we have already published, enables the local damage induced by the therapy to be estimated. The comparison performed in terms of the local damage induced by the therapy demonstrates that the FLEXITHERALIGHT protocol with lower fluence rate, light fractionation and shorter incubation time is somewhat less efficient than the standard protocol. Nevertheless, from the clinical trial results, the FLEXITHERALIGHT protocol results in non-inferior response rates compared to the standard protocol. This finding raises the question of whether the PDT local damage achieved by the FLEXITHERALIGHT protocol (respectively, the standard protocol) is sufficient (respectively, excessive) to destroy actinic keratosis cells. Lasers Surg. Med. 49:686-697, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Yushkevich, Paul A.; Amaral, Robert S. C.; Augustinack, Jean C.; Bender, Andrew R.; Bernstein, Jeffrey D.; Boccardi, Marina; Bocchetta, Martina; Burggren, Alison C.; Carr, Valerie A.; Chakravarty, M. Mallar; Chetelat, Gael; Daugherty, Ana M.; Davachi, Lila; Ding, Song-Lin; Ekstrom, Arne; Geerlings, Mirjam I.; Hassan, Abdul; Huang, Yushan; Iglesias, Eugenio; La Joie, Renaud; Kerchner, Geoffrey A.; LaRocque, Karen F.; Libby, Laura A.; Malykhin, Nikolai; Mueller, Susanne G.; Olsen, Rosanna K.; Palombo, Daniela J.; Parekh, Mansi B; Pluta, John B.; Preston, Alison R.; Pruessner, Jens C.; Ranganath, Charan; Raz, Naftali; Schlichting, Margaret L.; Schoemaker, Dorothee; Singh, Sachi; Stark, Craig E. L.; Suthana, Nanthia; Tompary, Alexa; Turowski, Marta M.; Van Leemput, Koen; Wagner, Anthony D.; Wang, Lei; Winterburn, Julie L.; Wisse, Laura E.M.; Yassa, Michael A.; Zeineh, Michael M.
2015-01-01
OBJECTIVE An increasing number of human in vivo magnetic resonance imaging (MRI) studies have focused on examining the structure and function of the subfields of the hippocampal formation (the dentate gyrus, CA fields 1–3, and the subiculum) and subregions of the parahippocampal gyrus (entorhinal, perirhinal, and parahippocampal cortices). The ability to interpret the results of such studies and to relate them to each other would be improved if a common standard existed for labeling hippocampal subfields and parahippocampal subregions. Currently, research groups label different subsets of structures and use different rules, landmarks, and cues to define their anatomical extents. This paper characterizes, both qualitatively and quantitatively, the variability in the existing manual segmentation protocols for labeling hippocampal and parahippocampal substructures in MRI, with the goal of guiding subsequent work on developing a harmonized substructure segmentation protocol. METHOD MRI scans of a single healthy adult human subject were acquired both at 3 Tesla and 7 Tesla. Representatives from 21 research groups applied their respective manual segmentation protocols to the MRI modalities of their choice. The resulting set of 21 segmentations was analyzed in a common anatomical space to quantify similarity and identify areas of agreement. RESULTS The differences between the 21 protocols include the region within which segmentation is performed, the set of anatomical labels used, and the extents of specific anatomical labels. The greatest overall disagreement among the protocols is at the CA1/subiculum boundary, and disagreement across all structures is greatest in the anterior portion of the hippocampal formation relative to the body and tail. CONCLUSIONS The combined examination of the 21 protocols in the same dataset suggests possible strategies towards developing a harmonized subfield segmentation protocol and facilitates comparison between published studies. PMID:25596463
Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D
2015-10-01
Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.
Schaun, Gustavo Z; Del Vecchio, Fabrício B
2018-01-01
Schaun, GZ and Del Vecchio, FB. High-intensity interval exercises' acute impact on heart rate variability: comparison between whole-body and cycle ergometer protocols. J Strength Cond Res 32(1): 223-229, 2018-Study aimed to compare the effects of 2 high-intensity interval training (HIIT) protocols on heart rate variability. Twelve young adult males (23.3 ± 3.9 years, 177.8 ± 7.4 cm, 76.9 ± 12.9 kg) volunteered to participate. In a randomized cross-over design, subjects performed 2 HIIT protocols, 1 on a cycle ergometer (Tabata protocol [TBT]; eight 20-second bouts at 170% Pmax interspersed by 10-second rest) and another with whole-body calisthenic exercises (McRae protocol; eight 20-second all-out intervals interspersed by 10-second rest). Heart rate variability outcomes in the time, frequency, and nonlinear domains were assessed on 3 moments: (a) presession; (b) immediately postsession; and (c) 24 hours postsession. Results revealed that RRmean, Ln rMSSD, Ln high frequency (HF), and Ln low frequency (LF) were significantly reduced immediately postsession (p ≤ 0.001) and returned to baseline 24 h after both protocols. In addition, LF/HF ratio was reduced 24 h postsession (p ≤ 0.01) and SD2 was significantly lower immediately postsession only in TBT. Our main finding was that responses from heart rate autonomic control were similar in both protocols, despite different modes of exercise performed. Specifically, exercises resulted in a high parasympathetic inhibition immediately after session with subsequent recovery within 1 day. These results suggest that subjects were already recovered the day after and can help coaches to better program training sessions with such protocols.
Dekkers, Olaf M; Cevallos, Myriam; Bührer, Jonas; Poncet, Antoine; Ackermann Rau, Sabine; Perneger, Thomas V; Egger, Matthias
2015-05-01
To compare noninferiority margins defined in study protocols and trial registry records with margins reported in subsequent publications. Comparison of protocols of noninferiority trials submitted 2001 to 2005 to ethics committees in Switzerland and The Netherlands with corresponding publications and registry records. We searched MEDLINE via PubMed, the Cochrane Controlled Trials Register (Cochrane Library issue 01/2012), and Google Scholar in September 2013 to identify published reports, and the International Clinical Trials Registry Platform of the World Health Organization in March 2013 to identify registry records. Two readers recorded the noninferiority margin and other data using a standardized data-abstraction form. The margin was identical in study protocol and publication in 43 (80%) of 54 pairs of study protocols and articles. In the remaining pairs, reporting was inconsistent (five pairs, 9%), or the noninferiority margin was either not reported in the publication (five pairs, 9%) or not defined in the study protocol (one pair). The confidence interval or the exact P-value required to judge whether the result was compatible with noninferior, inferior, or superior efficacy was reported in 43 (80%) publications. Complete and consistent reporting of both noninferiority margin and confidence interval (or exact P-value) was present in 39 (72%) protocol-publication pairs. Twenty-nine trials (54%) were registered in trial registries, but only one registry record included the noninferiority margin. The reporting of noninferiority margins was incomplete and inconsistent with study protocols in a substantial proportion of published trials, and margins were rarely reported in trial registries. Copyright © 2015 Elsevier Inc. All rights reserved.
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison.
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-04-16
To compare between 2 and 4 d colon cleansing protocols. Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Rate of adequate colon preparation. A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children's age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the "gold standard" protocol for children.
Zakaria, A; Schuette, W; Younan, C
2011-01-01
The preceding DIN 6800-2 (1997) protocol has been revised by a German task group and its latest version was published in March 2008 as the national standard dosimetry protocol DIN 6800-2 (2008 March). Since then, in Germany the determination of absorbed dose to water for high-energy photon and electron beams has to be performed according to this new German dosimetry protocol. The IAEA Code of Practice TRS 398 (2000) and the AAPM TG-51 are the two main protocols applied internationally. The new German version has widely adapted the methodology and dosimetric data of TRS-398. This paper investigates systematically the DIN 6800-2 protocol and compares it with the procedures and results obtained by using the international protocols. The investigation was performed with 6 MV and 18 MV photon beams as well as with electron beams from 5 MeV to 21 MeV. While only cylindrical chambers were used for photon beams, the measurements of electron beams were performed by using cylindrical and plane-parallel chambers. It was found that the discrepancies in the determination of absorbed dose to water among the three protocols were 0.23% for photon beams and 1.2% for electron beams. The determination of water absorbed dose was also checked by a national audit procedure using TLDs. The comparison between the measurements following the DIN 6800-2 protocol and the TLD audit-procedure confirmed a difference of less than 2%. The advantage of the new German protocol DIN 6800-2 lies in the renouncement on the cross calibration procedure as well as its clear presentation of formulas and parameters. In the past, the different protocols evoluted differently from time to time. Fortunately today, a good convergence has been obtained in concepts and methods. PMID:22287987
Zakaria, A; Schuette, W; Younan, C
2011-04-01
The preceding DIN 6800-2 (1997) protocol has been revised by a German task group and its latest version was published in March 2008 as the national standard dosimetry protocol DIN 6800-2 (2008 March). Since then, in Germany the determination of absorbed dose to water for high-energy photon and electron beams has to be performed according to this new German dosimetry protocol. The IAEA Code of Practice TRS 398 (2000) and the AAPM TG-51 are the two main protocols applied internationally. The new German version has widely adapted the methodology and dosimetric data of TRS-398. This paper investigates systematically the DIN 6800-2 protocol and compares it with the procedures and results obtained by using the international protocols. The investigation was performed with 6 MV and 18 MV photon beams as well as with electron beams from 5 MeV to 21 MeV. While only cylindrical chambers were used for photon beams, the measurements of electron beams were performed by using cylindrical and plane-parallel chambers. It was found that the discrepancies in the determination of absorbed dose to water among the three protocols were 0.23% for photon beams and 1.2% for electron beams. The determination of water absorbed dose was also checked by a national audit procedure using TLDs. The comparison between the measurements following the DIN 6800-2 protocol and the TLD audit-procedure confirmed a difference of less than 2%. The advantage of the new German protocol DIN 6800-2 lies in the renouncement on the cross calibration procedure as well as its clear presentation of formulas and parameters. In the past, the different protocols evoluted differently from time to time. Fortunately today, a good convergence has been obtained in concepts and methods.
Medrano-Gracia, Pau; Cowan, Brett R; Bluemke, David A; Finn, J Paul; Kadish, Alan H; Lee, Daniel C; Lima, Joao A C; Suinesiaputra, Avan; Young, Alistair A
2013-09-13
Cardiovascular imaging studies generate a wealth of data which is typically used only for individual study endpoints. By pooling data from multiple sources, quantitative comparisons can be made of regional wall motion abnormalities between different cohorts, enabling reuse of valuable data. Atlas-based analysis provides precise quantification of shape and motion differences between disease groups and normal subjects. However, subtle shape differences may arise due to differences in imaging protocol between studies. A mathematical model describing regional wall motion and shape was used to establish a coordinate system registered to the cardiac anatomy. The atlas was applied to data contributed to the Cardiac Atlas Project from two independent studies which used different imaging protocols: steady state free precession (SSFP) and gradient recalled echo (GRE) cardiovascular magnetic resonance (CMR). Shape bias due to imaging protocol was corrected using an atlas-based transformation which was generated from a set of 46 volunteers who were imaged with both protocols. Shape bias between GRE and SSFP was regionally variable, and was effectively removed using the atlas-based transformation. Global mass and volume bias was also corrected by this method. Regional shape differences between cohorts were more statistically significant after removing regional artifacts due to imaging protocol bias. Bias arising from imaging protocol can be both global and regional in nature, and is effectively corrected using an atlas-based transformation, enabling direct comparison of regional wall motion abnormalities between cohorts acquired in separate studies.
The protocol describes the Environmental Technology Verification (ETV) Program's considerations and requirements for verification of emissions reduction provided by selective catalytic reduction (SCR) technologies. The basis of the ETV will be comparison of the emissions and perf...
Two deterministic models (US EPA’s Office of Pesticide Programs Residential Standard Operating Procedures (OPP Residential SOPs) and Draft Protocol for Measuring Children’s Non-Occupational Exposure to Pesticides by all Relevant Pathways (Draft Protocol)) and four probabilistic mo...
A Field Comparison of Sampling Protocols for Measuring Lead in Drinking Water
US EPA Region 5 conducted a sampling study that demonstrates existing sampling protocols used for the Lead and Copper Rule (LCR) underestimate peak and probable mass of lead released in a system with lead service lines (LSLs). This comparative stagnation sampling was conducted i...
Medium Access Control Protocols for Cognitive Radio Ad Hoc Networks: A Survey
Islam, A. K. M. Muzahidul; Baharun, Sabariah; Mansoor, Nafees
2017-01-01
New wireless network paradigms will demand higher spectrum use and availability to cope with emerging data-hungry devices. Traditional static spectrum allocation policies cause spectrum scarcity, and new paradigms such as Cognitive Radio (CR) and new protocols and techniques need to be developed in order to have efficient spectrum usage. Medium Access Control (MAC) protocols are accountable for recognizing free spectrum, scheduling available resources and coordinating the coexistence of heterogeneous systems and users. This paper provides an ample review of the state-of-the-art MAC protocols, which mainly focuses on Cognitive Radio Ad Hoc Networks (CRAHN). First, a description of the cognitive radio fundamental functions is presented. Next, MAC protocols are divided into three groups, which are based on their channel access mechanism, namely time-slotted protocol, random access protocol and hybrid protocol. In each group, a detailed and comprehensive explanation of the latest MAC protocols is presented, as well as the pros and cons of each protocol. A discussion on future challenges for CRAHN MAC protocols is included with a comparison of the protocols from a functional perspective. PMID:28926952
Hammond, Emily; Sloan, Chelsea; Newell, John D; Sieren, Jered P; Saylor, Melissa; Vidal, Craig; Hogue, Shayna; De Stefano, Frank; Sieren, Alexa; Hoffman, Eric A; Sieren, Jessica C
2017-09-01
Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction, and equivalent diameter had smaller measurement differences than area and perimeter measurements. In conclusion, the use of IR with low- and ultralow-dose CT protocols with CT volume dose indices down to 0.32 mGy maintains selected quantitative parenchymal and airway measurements relevant to pulmonary disease characterization. © 2017 American Association of Physicists in Medicine.
Znati, Sami A.; Chedid, Nicholas; Miao, Houxun; Chen, Lei; Bennett, Eric E.; Wen, Han
2016-01-01
Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of x-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in sub-micron-width silicon trenches with an aspect ratio greater than 35 over a grating area of several square centimeters is challenging and has not been described in the literature previously. A comparison of pulsed plating and constant current plating led to a gold electroplating protocol that reliably filled trenches for such structures. PMID:27042384
A secured authentication protocol for wireless sensor networks using elliptic curves cryptography.
Yeh, Hsiu-Lien; Chen, Tien-Ho; Liu, Pin-Chuan; Kim, Tai-Hoo; Wei, Hsin-Wen
2011-01-01
User authentication is a crucial service in wireless sensor networks (WSNs) that is becoming increasingly common in WSNs because wireless sensor nodes are typically deployed in an unattended environment, leaving them open to possible hostile network attack. Because wireless sensor nodes are limited in computing power, data storage and communication capabilities, any user authentication protocol must be designed to operate efficiently in a resource constrained environment. In this paper, we review several proposed WSN user authentication protocols, with a detailed review of the M.L Das protocol and a cryptanalysis of Das' protocol that shows several security weaknesses. Furthermore, this paper proposes an ECC-based user authentication protocol that resolves these weaknesses. According to our analysis of security of the ECC-based protocol, it is suitable for applications with higher security requirements. Finally, we present a comparison of security, computation, and communication costs and performances for the proposed protocols. The ECC-based protocol is shown to be suitable for higher security WSNs.
A Secured Authentication Protocol for Wireless Sensor Networks Using Elliptic Curves Cryptography
Yeh, Hsiu-Lien; Chen, Tien-Ho; Liu, Pin-Chuan; Kim, Tai-Hoo; Wei, Hsin-Wen
2011-01-01
User authentication is a crucial service in wireless sensor networks (WSNs) that is becoming increasingly common in WSNs because wireless sensor nodes are typically deployed in an unattended environment, leaving them open to possible hostile network attack. Because wireless sensor nodes are limited in computing power, data storage and communication capabilities, any user authentication protocol must be designed to operate efficiently in a resource constrained environment. In this paper, we review several proposed WSN user authentication protocols, with a detailed review of the M.L Das protocol and a cryptanalysis of Das’ protocol that shows several security weaknesses. Furthermore, this paper proposes an ECC-based user authentication protocol that resolves these weaknesses. According to our analysis of security of the ECC-based protocol, it is suitable for applications with higher security requirements. Finally, we present a comparison of security, computation, and communication costs and performances for the proposed protocols. The ECC-based protocol is shown to be suitable for higher security WSNs. PMID:22163874
Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios
2018-03-01
The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.
BIASES IN CASTNET FILTER PACK RESULTS ASSOCIATED WITH SAMPLING PROTOCOL
In the current study, single filter weekly (w) results are compared with weekly results aggregated from day and night (dn) weekly samples. Comparisons of the two sampling protocols for all major constituents (SO42-, NO3-, NH4+, HNO3, and SO2) show median bias (MB) of < 5 nmol m-3...
Bennett, Charles R; DiAngelo, Denis J; Kelly, Brian P
2015-01-01
Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension.
Bennett, Charles R.; DiAngelo, Denis J.
2015-01-01
Background Extremely few in-vitro biomechanical studies have incorporated shear loads leaving a gap for investigation, especially when applied in combination with compression and bending under dynamic conditions. The objective of this study was to biomechanically compare sagittal plane application of two standard protocols, pure moment (PM) and follower load (FL), with a novel trunk weight (TW) loading protocol designed to induce shear in combination with compression and dynamic bending in a neutrally potted human cadaveric L4-L5 motion segment unit (MSU) model. A secondary objective and novelty of the current study was the application of all three protocols within the same testing system serving to reduce artifacts due to testing system variability. Methods Six L4-L5 segments were tested in a Cartesian load controlled system in flexion-extension to 8Nm under PM, simulated ideal 400N FL, and vertically oriented 400N TW loading protocols. Comparison metrics used were rotational range of motion (RROM), flexibility, neutral zone (NZ) range of motion, and L4 vertebral body displacements. Results Significant differences in vertebral body translations were observed with different initial force applications but not with subsequent bending moment application. Significant reductions were observed in combined flexion-extension RROM, in flexibility during extension, and in NZ region flexibility with the TW loading protocol as compared to PM loading. Neutral zone ranges of motion were not different between all protocols. Conclusions The combined compression and shear forces applied across the spinal joint in the trunk weight protocol may have a small but significantly increased stabilizing effect on segment flexibility and kinematics during sagittal plane flexion and extension. PMID:26273551
Rosito, G; Sum, K; Chorne, N
2010-10-01
Indomethacin, a non-selective inhibitor of prostaglandin synthesis, is the gold standard treatment for patent ductus arteriosus (PDA). Indomethacin has been shown to permanently close the ductus and when given prophylactically, it reduces the incidence of PDA (1, 2). This study compares PDA closure and surgical ligation rates between patients using two different indomethacin administration protocols. This is a retrospective comparison analysis of 72 neonates, who received one of two indomethacin administration protocols. Our previous protocol suggested an initial dose of 0·2 mg/kg followed by two 0·1 mg/kg, with doses infused over 4 h and a 24-h dosing interval. A new potentially more useful protocol using the same mg/kg dose regimen but with doses infused over 30 min and a 12-h dosing interval, was evaluated. Each neonate was allowed three courses of treatment before surgical ligation was performed for persistent PDA. There were no statistically significant differences between the two protocol groups when comparing percentages of neonates with gestational age≤28 weeks, birth weight≤1000 g, male gender or receiving indomethacin for the indication of PDA prophylaxis vs. treatment. There was a trend towards a higher PDA closure rate and subsequently a lower PDA ligation rate in the new protocol when compared with the previous protocol. In this small population of premature neonates, there was a trend, but no significant difference, towards increasing PDA closure and lower surgical ligation rates in neonates given indomethacin with more frequent dosing and shorter infusion time. A well-powered randomized controlled trial is now needed. Copyright © 2010 The Authors. JCPT © 2010 Blackwell Publishing Ltd.
Polyethylene glycol 3350 based colon cleaning protocol: 2 d vs 4 d head to head comparison
Elitsur, Rotem; Butcher, Lisa; Vicki, Lund; Elitsur, Yoram
2013-01-01
AIM: To compare between 2 and 4 d colon cleansing protocols. METHODS: Children who were scheduled for colonoscopy procedure (2010-2012) for various medical reasons, were recruited from the pediatric gastroenterology clinic at Marshall University School of Medicine, Huntington, WV. Exclusion criteria were patients who were allergic to the medication used in the protocols [polyethylene glycol (PEG) 3350, Bisacodyl], or children with metabolic or renal diseases. Two PEG 3350 protocols for 4 d (A) and 2 d (B) were prescribed as previously described. A questionnaire describing the volume of PEG consumed, clinical data, and side effects were recorded. Colon preparation was graded by two observers according to previously described method. Main outcome measurements: Rate of adequate colon preparation. RESULTS: A total of 78 patients were considered for final calculation (group A: 40, group B: 38). Age and stool consistency at the last day was comparable in both groups, but the number of stools/day was significantly higher in group B (P = 0.001). Adequate colon preparation was reached in 57.5% (A) and 73.6% (B), respectively (P = 0.206). Side effects were minimal and comparable in both groups. There was no difference in children’s age, stool characteristics, or side effects between the children with adequate or inadequate colon preparation. Correlation and agreement between observers was excellent (Pearson correlation = 0.972, kappa = 1.0). CONCLUSION: No difference between protocols was observed, but the 2 d protocol was superior for its shorter time. Direct comparison between different colon cleansing protocols is crucial in order to establish the “gold standard” protocol for children. PMID:23596539
A Standard Mutual Authentication Protocol for Cloud Computing Based Health Care System.
Mohit, Prerna; Amin, Ruhul; Karati, Arijit; Biswas, G P; Khan, Muhammad Khurram
2017-04-01
Telecare Medical Information System (TMIS) supports a standard platform to the patient for getting necessary medical treatment from the doctor(s) via Internet communication. Security protection is important for medical records (data) of the patients because of very sensitive information. Besides, patient anonymity is another most important property, which must be protected. Most recently, Chiou et al. suggested an authentication protocol for TMIS by utilizing the concept of cloud environment. They claimed that their protocol is patient anonymous and well security protected. We reviewed their protocol and found that it is completely insecure against patient anonymity. Further, the same protocol is not protected against mobile device stolen attack. In order to improve security level and complexity, we design a light weight authentication protocol for the same environment. Our security analysis ensures resilience of all possible security attacks. The performance of our protocol is relatively standard in comparison with the related previous research.
Fallah, F; Minaei Chenar, H; Amiri, H; Omodipour, S; Shirbande Ghods, F; Kahrizi, D; Sohrabi, M; Ghorbani, T; Kazemi, E
2017-02-28
High quality DNA is essential for molecular research. Secondary metabolites can affect the quantity and quality DNA. In current research two DNA isolation methods including CTAB and Delaporta (protocols 1 & 2 respectively) were applied in three leave samples from Cotinus coggygria, Citrus sinensis and Genus juglans that their leaves are rich of secondary metabolites. We successfully isolated DNA from C. coggygria, C. sinensis and Genus Juglans using the two protocols described above. Good quality DNA was isolated from C. coggygria, C. sinensis and Genus Juglans using protocol 1, while protocol 2 failed to produce usable DNA from these sources. The highest amount of DNA (1.3-1.6) was obtained from them using protocol 1. As we discovered, procedure 1 may work better for plants with secondary metabolites.
Elsholtz, Fabian Henry Jürgen; Kamp, Julia Evi-Katrin; Vahldiek, Janis Lucas; Hamm, Bernd; Niehues, Stefan Markus
2018-06-18
CT-guided periradicular infiltration of the cervical spine is an effective symptomatic treatment in patients with radiculopathy-associated pain syndromes. This study evaluates the robustness and safety of a low-dose protocol on a CT scanner with iterative reconstruction software. A total of 183 patients who underwent periradicular infiltration therapy of the cervical spine were included in this study. 82 interventions were performed on a new CT scanner with a new intervention protocol using an iterative reconstruction algorithm. Spot scanning was implemented for planning and a basic low-dose setup of 80 kVp and 5 mAs was established during intermittent fluoroscopy. The comparison group included 101 prior interventions on a scanner without iterative reconstruction. The dose-length product (DLP), number of acquisitions, pain reduction on a numeric analog scale, and protocol changes to achieve a safe intervention were recorded. The median DLP for the whole intervention was 24.3 mGy*cm in the comparison group and 1.8 mGy*cm in the study group. The median pain reduction was -3 in the study group and -2 in the comparison group. A 5 mAs increase in the tube current-time product was required in 5 patients of the study group. Implementation of a new scanner and intervention protocol resulted in a 92.6 % dose reduction without a compromise in safety and pain relief. The dose needed here is more than 75 % lower than doses used for similar interventions in published studies. An increase of the tube current-time product was needed in only 6 % of interventions. · The presented ultra-low-dose protocol allows for a significant dose reduction without compromising outcome.. · The protocol includes spot scanning for planning purposes and a basic setup of 80 kVp and 5 mAs.. · The iterative reconstruction algorithm is activated during fluoroscopy.. · Elsholtz FH, Kamp JE, Vahldiek JL et al. Periradicular Infiltration of the Cervical Spine: How New CT Scanner Techniques and Protocol Modifications Contribute to the Achievement of Low-Dose Interventions. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0632-3930. © Georg Thieme Verlag KG Stuttgart · New York.
Monolithic master oscillator power amplifier at 1.58 μm for lidar measurements
NASA Astrophysics Data System (ADS)
Faugeron, M.; Krakowski, M.; Robert, Y.; Vinet, E.; Primiani, P.; Le Goëc, J. P.; Parillaud, O.; van Dijk, F.; Vilera, M.; Consoli, A.; Tijero, J. M. G.; Esquivias, I.
2017-11-01
Nowadays the interest in high power semiconductor devices is growing for applications such as telemetry, lidar system or free space communications. Indeed semiconductor devices can be an alternative to solid state lasers because they are more compact and less power consuming. These characteristics are very important for constrained and/or low power supply environment such as airplanes or satellites. Lots of work has been done in the 800-1200 nm range for integrated and free space Master Oscillator Power Amplifier (MOPA) [1]-[3]. At 1.5 μm, the only commercially available MOPA is from QPC [4]: the fibred output power is about 700 mW and the optical linewidth is 500 kHz. In this paper, we first report on the simulations we have done to determine the appropriate vertical structure and architecture for a good MOPA at 1.58 μm (section II). Then we describe the fabrication of the devices (section III). Finally we report on the optical and electrical measurements we have done for various devices (section IV).
Lundqvist, Lars-Olov; Ivarsson, Ann-Britt; Rask, Mikael; Brunt, David; Schröder, Agneta
2018-05-01
Community-based day centres in Sweden are well-established arenas for psychiatric rehabilitation, but little is known of the attendees' perception of the quality of the service provided. The aim of the study was thus to describe and investigate the quality of the services in community-based day centre for people with psychiatric disabilities. A sample of 218 attendees in 14 community-based day centre services in Sweden completed the Quality in Psychiatric Care - Daily Activities (QPC-DA). The results showed that people with psychiatric disabilities perceived the quality of community-based day centre services as high. Most notably, quality of service was rated higher by those with lower educational level, had waited shorter time to attend the centre, and had better mental and physical health. However, particularly aspects of a secluded environment and participation (information) may be areas with potential for improvement. From an occupational science perspective, the results adhere to the importance of occupational balance, with periods of rest/privacy during the time at the centre.
Statistics attack on `quantum private comparison with a malicious third party' and its improvement
NASA Astrophysics Data System (ADS)
Gu, Jun; Ho, Chih-Yung; Hwang, Tzonelih
2018-02-01
Recently, Sun et al. (Quantum Inf Process:14:2125-2133, 2015) proposed a quantum private comparison protocol allowing two participants to compare the equality of their secrets via a malicious third party (TP). They designed an interesting trap comparison method to prevent the TP from knowing the final comparison result. However, this study shows that the malicious TP can use the statistics attack to reveal the comparison result. A simple modification is hence proposed to solve this problem.
NASA Astrophysics Data System (ADS)
Panteliadis, P.; Hafkenscheid, T.; Cary, B.; Diapouli, E.; Fischer, A.; Favez, O.; Quincey, P.; Viana, M.; Hitzenberger, R.; Vecchi, R.; Saraga, D.; Sciare, J.; Jaffrezo, J. L.; John, A.; Schwarz, J.; Giannoni, M.; Novak, J.; Karanasiou, A.; Fermo, P.; Maenhaut, W.
2015-02-01
A comparison exercise on thermal-optical elemental carbon/organic carbon (ECOC) analysers was carried out among 17 European laboratories. Contrary to previous comparison exercises, the 17 participants made use of an identical instrument set-up, after correcting for temperature offsets with the application of a recently developed temperature calibration kit (Sunset Laboratory Inc, OR, US). Temperature offsets reported by participants ranged from -93 to +100 °C per temperature step. Five filter samples and two sucrose solutions were analysed with both the EUSAAR2 and NIOSH870 thermal protocols. z scores were calculated for total carbon (TC); nine outliers and three stragglers were identified. Three outliers and eight stragglers were found for EC. Overall, the participants provided results between the warning levels with the exception of two laboratories that showed poor performance, the causes of which were identified and corrected through the course of the comparison exercise. The TC repeatability and reproducibility (expressed as relative standard deviations) were 11 and 15% for EUSAAR2 and 9.2 and 12% for NIOSH870; the standard deviations for EC were 15 and 20% for EUSAAR2 and 20 and 26% for NIOSH870. TC was in good agreement between the two protocols, TCNIOSH870 = 0.98 × TCEUSAAR2 (R2 = 1.00, robust means). Transmittance (TOT) calculated EC for NIOSH870 was found to be 20% lower than for EUSAAR2, ECNIOSH870 = 0.80 × ECEUSAAR2 (R2 = 0.96, robust means). The thermograms and laser signal values were compared and similar peak patterns were observed per sample and protocol for most participants. Notable deviations from the typical patterns indicated either the absence or inaccurate application of the temperature calibration procedure and/or pre-oxidation during the inert phase of the analysis. Low or zero pyrolytic organic carbon (POC), as reported by a few participants, is suggested as an indicator of an instrument-specific pre-oxidation. A sample-specific pre-oxidation effect was observed for filter G, for all participants and both thermal protocols, indicating the presence of oxygen donors on the suspended particulate matter. POC (TOT) levels were lower for NIOSH870 than for EUSAAR2, which is related to the heating profile differences of the two thermal protocols.
Comparison of VDL Modes in the Aeronautical Telecommunications Network
NASA Technical Reports Server (NTRS)
Bretmersky, Steven; Konangi, Vijay K.; Kerczewski, Robert J.
2002-01-01
VHF Digital Link (VDL) has been identified as a method of communication between aircraft and ground stations in the Aeronautical Telecommunications Network (ATN). Three different modes of VDL have been suggested for implementation. Simulations were conducted to compare the data transfer capabilities of VDL Modes 2, 3, and 4. These simulations focus on up to 50 aircraft communicating with a single VDL ground station. The data traffic is generated by the standard File Transfer Protocol (FTP) and Hyper Text Transfer Protocol (HTTP) applications in the aircraft. Comparisons of the modes are based on the number of files and pages transferred and the response time.
Standardizing Quality Assessment of Fused Remotely Sensed Images
NASA Astrophysics Data System (ADS)
Pohl, C.; Moellmann, J.; Fries, K.
2017-09-01
The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.
ERIC Educational Resources Information Center
Kavale, Kenneth A.
Sixteen sixth-grade students participated in a study of the reasoning strategies employed by good and poor readers. Students, trained in applying introspective procedures, completed instruments that measured verbal reasoning, determining cause and effect, reading for inference, and determining main idea. Protocols obtained during five consecutive…
ERIC Educational Resources Information Center
Lovett, Sadie; Rehfeldt, Ruth Anne; Garcia, Yors; Dunning, Johnna
2011-01-01
This study compared the effects of a computer-based stimulus equivalence protocol to a traditional lecture format in teaching single-subject experimental design concepts to undergraduate students. Participants were assigned to either an equivalence or a lecture group, and performance on a paper-and-pencil test that targeted relations among the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suckling, Tara; Smith, Tony; Reed, Warren
2013-06-15
Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 andmore » February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.« less
Shastri, Shefali M; Barbieri, Elizabeth; Kligman, Isaac; Schoyer, Katherine D; Davis, Owen K; Rosenwaks, Zev
2011-02-01
To evaluate in vitro fertilization (IVF) cycle outcomes in young poor responders treated with a luteal estradiol/gonadotropin-releasing hormone antagonist (E(2)/ANT) protocol versus an oral contraceptive pill microdose leuprolide protocol (OCP-MDL). Retrospective cohort. Academic practice. Poor responders: 186 women, aged <35 years undergoing IVF with either E(2)/ANT or OCP-MDL protocols. None. Clinical pregnancies, oocytes retrieved, cancellation rate. Patients in the E(2)/ANT group had a greater gonadotropin requirement (71.9 ± 22.2 vs. 57.6 ± 25.7) and lower E(2) level (1,178.6 ± 668 vs. 1,627 ± 889), yet achieved similar numbers of oocytes retrieved and fertilized, and a greater number of embryos transferred (2.3 ± 0.9 vs. 2.0 ± 1.1) with a better mean grade (2.14 ± .06 vs. 2.7 ± 1.8) compared with the OCP/MDL group. The E2/ANT group exhibited a trend toward improved implantation rates (30.5% vs. 21.1%) and ongoing pregnancy rates per started cycle: 44 out of 117 (37%) versus 17 out of 69 (25%). Poor responders aged <35 years may be treated with the aggressive E(2)/ANT protocol to improve cycle outcomes. Both protocols remain viable options for this group. Adequately powered, randomized clinical comparison appears justified. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Trochesset, Denise A; Serchuk, Richard B; Colosi, Dan C
2014-03-01
Identification of unknown individuals using dental comparison is well established in the forensic setting. The identification technique can be time and resource consuming if many individuals need to be identified at once. Medical CT (MDCT) for dental profiling has had limited success, mostly due to artifact from metal-containing dental restorations and implants. The authors describe a CBCT reformatting technique that creates images, which closely approximate conventional dental images. Using a i-CAT Platinum CBCT unit and standard issue i-CAT Vision software, a protocol is developed to reproducibly and reliably reformat CBCT volumes. The reformatted images are presented with conventional digital images from the same anatomic area for comparison. The authors conclude that images derived from CBCT volumes following this protocol are similar enough to conventional dental radiographs to allow for dental forensic comparison/identification and that CBCT offers a superior option over MDCT for this purpose. © 2013 American Academy of Forensic Sciences.
Comparison of COAP and UW-19 protocols for dogs with multicentric lymphoma.
Hosoya, Kenji; Kisseberth, William C; Lord, Linda K; Alvarez, Francisco J; Lara-Garcia, Ana; Kosarek, Carrie E; London, Cheryl A; Couto, C Guillermo
2007-01-01
Various chemotherapy protocols for treating lymphoma in dogs have been published; however, comparison of protocols from different studies is difficult, especially when evaluating survival time and toxicoses. The choice of COAP (C, cyclophosphamide; O, vincristine; A, cytosine arabinoside; P, prednisone) and a modified University of Wisconsin 19-week (UW-19) induction protocol has no influence on overall survival times in dogs with lymphoma. One hundred and one dogs with multicentric lymphoma. Retrospective study (2001-2006). Dogs induced with either an 8-week COP-based protocol (C, cyclophosphamide; O, vincristine; and P, prednisone) with maintenance therapy (COAP group) or a 19-week CHOP (C, cyclophosphamide; H, doxorubicin; O, vincristine; and P, prednisone) based protocol (UW-19 group) were compared in terms of the duration of first remission, survival time, toxicoses, and cost. There were 71 dogs in the COAP group and 30 dogs in the UW-19 group. Various protocols were used after the first relapse. The median duration of the first remission for the COAP and UW-19 groups were 94 days (range, 6-356 days) and 174 days (28-438 days), respectively (P < .01). The median survival times for dogs in the COAP and UW-19 groups were 309 days (6-620 days) and 275 days (70-1102+ days), respectively (P = .09). Dogs in the COAP group had a hazard ratio of 1.9 (95% CI 1.1-3.4) for death relative to the UW-19 group (P = .03), after controlling for the confounders (World Health Organization clinical stage, age, sex, use of doxorubicin during reinduction). The severity of neutropenia and gastrointestinal toxicoses were significantly higher in the UW-19 group than in the COAP group (P = .01 and P < .01, respectively). Use of a long-term doxorubicin-containing sequential combination chemotherapy protocol is associated with a decreased risk of relapse and death relative to a non-doxorubicin-containing protocol.
Herts, Brian R; Baker, Mark E; Obuchowski, Nancy; Primak, Andrew; Schneider, Erika; Rhana, Harpreet; Dong, Frank
2013-06-01
The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders.
Chaimani, Anna; Caldwell, Deborah M; Li, Tianjing; Higgins, Julian P T; Salanti, Georgia
2017-03-01
The number of systematic reviews that aim to compare multiple interventions using network meta-analysis is increasing. In this study, we highlight aspects of a standard systematic review protocol that may need modification when multiple interventions are to be compared. We take the protocol format suggested by Cochrane for a standard systematic review as our reference and compare the considerations for a pairwise review with those required for a valid comparison of multiple interventions. We suggest new sections for protocols of systematic reviews including network meta-analyses with a focus on how to evaluate their assumptions. We provide example text from published protocols to exemplify the considerations. Standard systematic review protocols for pairwise meta-analyses need extensions to accommodate the increased complexity of network meta-analysis. Our suggested modifications are widely applicable to both Cochrane and non-Cochrane systematic reviews involving network meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.
Packet-Based Protocol Efficiency for Aeronautical and Satellite Communications
NASA Technical Reports Server (NTRS)
Carek, David A.
2005-01-01
This paper examines the relation between bit error ratios and the effective link efficiency when transporting data with a packet-based protocol. Relations are developed to quantify the impact of a protocol s packet size and header size relative to the bit error ratio of the underlying link. These relations are examined in the context of radio transmissions that exhibit variable error conditions, such as those used in satellite, aeronautical, and other wireless networks. A comparison of two packet sizing methodologies is presented. From these relations, the true ability of a link to deliver user data, or information, is determined. Relations are developed to calculate the optimal protocol packet size forgiven link error characteristics. These relations could be useful in future research for developing an adaptive protocol layer. They can also be used for sizing protocols in the design of static links, where bit error ratios have small variability.
Distributed synchronization of networked drive-response systems: A nonlinear fixed-time protocol.
Zhao, Wen; Liu, Gang; Ma, Xi; He, Bing; Dong, Yunfeng
2017-11-01
The distributed synchronization of networked drive-response systems is investigated in this paper. A novel nonlinear protocol is proposed to ensure that the tracking errors converge to zeros in a fixed-time. By comparison with previous synchronization methods, the present method considers more practical conditions and the synchronization time is not dependent of arbitrary initial conditions but can be offline pre-assign according to the task assignment. Finally, the feasibility and validity of the presented protocol have been illustrated by a numerical simulation. Copyright © 2017. Published by Elsevier Ltd.
Machen, Alexandra; Kobayashi, Miwako; Connelly, Mary Robin
2013-01-01
Two novel protocols for inactivation and extraction were developed and used to identify 107 Mycobacterium clinical isolates, including Mycobacterium tuberculosis complex, from solid cultures using Vitek matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry. The protocol using heat inactivation with sonication and cell disruption with glass beads resulted in 82.2% and 88.8% species and genus level identifications, respectively. PMID:24068013
The Quantum-to-Classical Transition in Strongly Interacting Nanoscale Systems
NASA Astrophysics Data System (ADS)
Benatov, Latchezar Latchezarov
This thesis comprises two separate but related studies, dealing with two strongly interacting nanoscale systems on the border between the quantum and classical domains. In Part 1, we use a Born-Markov approximated master equation approach to study the symmetrized-in-frequency current noise spectrum and the oscillator steady state of a nanoelectromechanical system where a nanoscale resonator is coupled linearly via its momentum to a quantum point contact (QPC). Our current noise spectra exhibit clear signatures of the quantum correlations between the QPC current and the back-action force on the oscillator at a value of the relative tunneling phase where such correlations are expected to be maximized. We also show that the steady state of the oscillator obeys a classical Fokker-Planck equation, but can experience thermomechanical noise squeezing in the presence of a momentum-coupled detector bath and a position-coupled environmental bath. Besides, the full master equation clearly shows that half of the detector back-action is correlated with electron tunneling, indicating a departure from the model of the detector as an effective bath and suggesting that a future calculation valid at lower bias voltage, stronger tunneling and/or stronger coupling might reveal interesting quantum effects in the oscillator dynamics. In the second part of the thesis, we study the subsystem dynamics and thermalization of an oscillator-spin star model, where a nanomechanical resonator is coupled to a few two-level systems (TLS's). We use a fourth-order Runge-Kutta numerical algorithm to integrate the Schrodinger equation for the system and obtain our results. We find that the oscillator reaches a Boltzmann steady state when the TLS bath is initially in a thermal state at a temperature higher than the oscillator phonon energy. This occurs in both chaotic and integrable systems, and despite the small number of spins (only six) and the lack of couplings between them. At the same time, pure initial states do not thermalize well in our system, indicating that mixed state thermalization stems from the thermal nature of the initial bath state. Under the influence of a thermal TLS bath, oscillator Fock states decay in an approximately exponential manner, but there is also a concave-down trend at very early times, possibly indicative of Gaussian decay. In the case of initial Fock state superpositions, the diagonal density matrix element behaves very similarly to single initial Fock states, while the off-diagonal matrix element decays sinusoidally with an exponentially decreasing amplitude. The off-diagonal decay time is much smaller then the diagonal one, indicating that superposition states decohere much faster than they decay. Both decay times decrease with increasing Fock state number, but more slowly than the 1/n dependence seen in the presence of an external ohmic bath.
The Virtual Insect Brain protocol: creating and comparing standardized neuroanatomy
Jenett, Arnim; Schindelin, Johannes E; Heisenberg, Martin
2006-01-01
Background In the fly Drosophila melanogaster, new genetic, physiological, molecular and behavioral techniques for the functional analysis of the brain are rapidly accumulating. These diverse investigations on the function of the insect brain use gene expression patterns that can be visualized and provide the means for manipulating groups of neurons as a common ground. To take advantage of these patterns one needs to know their typical anatomy. Results This paper describes the Virtual Insect Brain (VIB) protocol, a script suite for the quantitative assessment, comparison, and presentation of neuroanatomical data. It is based on the 3D-reconstruction and visualization software Amira, version 3.x (Mercury Inc.) [1]. Besides its backbone, a standardization procedure which aligns individual 3D images (series of virtual sections obtained by confocal microscopy) to a common coordinate system and computes average intensities for each voxel (volume pixel) the VIB protocol provides an elaborate data management system for data administration. The VIB protocol facilitates direct comparison of gene expression patterns and describes their interindividual variability. It provides volumetry of brain regions and helps to characterize the phenotypes of brain structure mutants. Using the VIB protocol does not require any programming skills since all operations are carried out at an intuitively usable graphical user interface. Although the VIB protocol has been developed for the standardization of Drosophila neuroanatomy, the program structure can be used for the standardization of other 3D structures as well. Conclusion Standardizing brains and gene expression patterns is a new approach to biological shape and its variability. The VIB protocol provides a first set of tools supporting this endeavor in Drosophila. The script suite is freely available at [2] PMID:17196102
The Traffic Adaptive Data Dissemination (TrAD) Protocol for both Urban and Highway Scenarios.
Tian, Bin; Hou, Kun Mean; Zhou, Haiying
2016-06-21
The worldwide economic cost of road crashes and injuries is estimated to be US$518 billion per year and the annual congestion cost in France is estimated to be €5.9 billion. Vehicular Ad hoc Networks (VANETs) are one solution to improve transport features such as traffic safety, traffic jam and infotainment on wheels, where a great number of event-driven messages need to be disseminated in a timely way in a region of interest. In comparison with traditional wireless networks, VANETs have to consider the highly dynamic network topology and lossy links due to node mobility. Inter-Vehicle Communication (IVC) protocols are the keystone of VANETs. According to our survey, most of the proposed IVC protocols focus on either highway or urban scenarios, but not on both. Furthermore, too few protocols, considering both scenarios, can achieve high performance. In this paper, an infrastructure-less Traffic Adaptive data Dissemination (TrAD) protocol which takes into account road traffic and network traffic status for both highway and urban scenarios will be presented. TrAD has double broadcast suppression techniques and is designed to adapt efficiently to the irregular road topology. The performance of the TrAD protocol was evaluated quantitatively by means of realistic simulations taking into account different real road maps, traffic routes and vehicular densities. The obtained simulation results show that TrAD is more efficient in terms of packet delivery ratio, number of transmissions and delay in comparison with the performance of three well-known reference protocols. Moreover, TrAD can also tolerate a reasonable degree of GPS drift and still achieve efficient data dissemination.
The Traffic Adaptive Data Dissemination (TrAD) Protocol for both Urban and Highway Scenarios
Tian, Bin; Hou, Kun Mean; Zhou, Haiying
2016-01-01
The worldwide economic cost of road crashes and injuries is estimated to be US$518 billion per year and the annual congestion cost in France is estimated to be €5.9 billion. Vehicular Ad hoc Networks (VANETs) are one solution to improve transport features such as traffic safety, traffic jam and infotainment on wheels, where a great number of event-driven messages need to be disseminated in a timely way in a region of interest. In comparison with traditional wireless networks, VANETs have to consider the highly dynamic network topology and lossy links due to node mobility. Inter-Vehicle Communication (IVC) protocols are the keystone of VANETs. According to our survey, most of the proposed IVC protocols focus on either highway or urban scenarios, but not on both. Furthermore, too few protocols, considering both scenarios, can achieve high performance. In this paper, an infrastructure-less Traffic Adaptive data Dissemination (TrAD) protocol which takes into account road traffic and network traffic status for both highway and urban scenarios will be presented. TrAD has double broadcast suppression techniques and is designed to adapt efficiently to the irregular road topology. The performance of the TrAD protocol was evaluated quantitatively by means of realistic simulations taking into account different real road maps, traffic routes and vehicular densities. The obtained simulation results show that TrAD is more efficient in terms of packet delivery ratio, number of transmissions and delay in comparison with the performance of three well-known reference protocols. Moreover, TrAD can also tolerate a reasonable degree of GPS drift and still achieve efficient data dissemination. PMID:27338393
ACIX: Atmospheric Correction Inter-comparison Exercise
NASA Astrophysics Data System (ADS)
Doxani, Georgia; Gascon, Ferran; Vermote, Éric; Roger, Jean-Claude
2017-04-01
The free and open data access policy to Sentinel-2 (S-2) and Landsat-8 (L-8) satellite imagery has stimulated the development of atmospheric correction (AC) processors for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for S-2 and L-8 missions. To this end, the European Space Agency (ESA) and NASA are organizing an exercise on AC processors inter-comparison. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 13 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. A protocol describing the inter-comparison process and the test dataset, which is based on the AERONET sites, will be presented. The protocol has been defined according to what was agreed among the participants during the 1st ACIX workshop held in June 2016. It includes the comparison of aerosol optical thickness and water vapour products of the processors with the AERONET measurements. Moreover, concerning the surface reflectances, the protocol describes the inter-comparison among the processors, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes will be presented and discussed among the participants in the 2nd ACIX workshop, which will be held on 11-12 April 2017 (ESRIN/ESA). The proposed presentation is an opportunity for the user community to be informed for the first time about the ACIX results and conclusions.
A major use of multi-walled carbon nanotubes (MWCNTs) is as functional fillers embedded in a solid matrix, such as plastics or coatings. Weathering and abrasion of the solid matrix during use can lead to environmental releases of the MWCNTs. Here we focus on a protocol to identif...
Zakaria, Golam Abu; Schuette, Wilhelm
2007-01-01
For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit. PMID:21217912
Zakaria, Golam Abu; Schuette, Wilhelm
2007-01-01
For the determination of the absorbed dose to water for high-energy photon and electron beams the IAEA code of practice TRS-398 (2000) is applied internationally. In Germany, the German dosimetry protocol DIN 6800-2 (1997) is used. Recently, the DIN standard has been revised and published as Draft National Standard DIN 6800-2 (2006). It has adopted widely the methodology and dosimetric data of the code of practice. This paper compares these three dosimetry protocols systematically and identifies similarities as well as differences. The investigation was done with 6 and 18 MV photon as well as 5 to 21 MeV electron beams. While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using cylindrical as well as plane-parallel chambers. The discrepancies in the determination of absorbed dose to water between the three protocols were 0.4% for photon beams and 1.5% for electron beams. Comparative measurements showed a deviation of less than 0.5% between our measurements following protocol DIN 6800-2 (2006) and TLD inter-comparison procedure in an external audit.
Comparison of PCR methods for the detection of genetic variants of carp edema virus.
Adamek, Mikolaj; Matras, Marek; Jung-Schroers, Verena; Teitge, Felix; Heling, Max; Bergmann, Sven M; Reichert, Michal; Way, Keith; Stone, David M; Steinhagen, Dieter
2017-09-20
The infection of common carp and its ornamental variety, koi, with the carp edema virus (CEV) is often associated with the occurrence of a clinical disease called 'koi sleepy disease'. The disease may lead to high mortality in both koi and common carp populations. To prevent further spread of the infection and the disease, a reliable detection method for this virus is required. However, the high genetic variability of the CEV p4a gene used for PCR-based diagnostics could be a serious obstacle for successful and reliable detection of virus infection in field samples. By analysing 39 field samples from different geographical origins obtained from koi and farmed carp and from all 3 genogroups of CEV, using several recently available PCR protocols, we investigated which of the protocols would allow the detection of CEV from all known genogroups present in samples from Central European carp or koi populations. The comparison of 5 different PCR protocols showed that the PCR assays (both end-point and quantitative) developed in the Centre for Environment, Fisheries and Aquaculture Science exhibited the highest analytical inclusivity and diagnostic sensitivity. Currently, this makes them the most suitable protocols for detecting viruses from all known CEV genogroups.
Coelho, F; Aguiar, L F; Cunha, G S P; Cardinot, N; Lucena, E
2014-01-01
The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate.
Network protocols for real-time applications
NASA Technical Reports Server (NTRS)
Johnson, Marjory J.
1987-01-01
The Fiber Distributed Data Interface (FDDI) and the SAE AE-9B High Speed Ring Bus (HSRB) are emerging standards for high-performance token ring local area networks. FDDI was designed to be a general-purpose high-performance network. HSRB was designed specifically for military real-time applications. A workshop was conducted at NASA Ames Research Center in January, 1987 to compare and contrast these protocols with respect to their ability to support real-time applications. This report summarizes workshop presentations and includes an independent comparison of the two protocols. A conclusion reached at the workshop was that current protocols for the upper layers of the Open Systems Interconnection (OSI) network model are inadequate for real-time applications.
Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela
2018-06-01
We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.
COMPARISON OF CFC-114 AND HFC-236EA PERFORMANCE IN SHIPBOARD VAPOR COMPRESSION SYSTEMS
The report gives results of a comparison of the performance of two refrigerants - 1,1,1,2,3,3-hexafluoropropane (HFC-236ea) and 1,2-dichloro-tetrafluoroethane (CFC-114) - in shipboard vapor compression refrigeration systems. (NOTE: In compliance with the Montreal Protocol and Dep...
Telehealth Protocol to Prevent Readmission Among High-Risk Patients With Congestive Heart Failure.
Rosen, Daniel; McCall, Janice D; Primack, Brian A
2017-11-01
Congestive heart failure is the leading cause of hospital readmissions. We aimed to assess adherence to and effectiveness of a telehealth protocol designed to prevent hospital admissions for congestive heart failure. We recruited a random sample of 50 patients with congestive heart failure (mean age 61 years) from a managed care organization. We developed a telehealth platform allowing for daily, real-time reporting of health status and video conferencing. We defined adherence as the percentage of days on which the patient completed the daily check-in protocol. To assess efficacy, we compared admission and readmission rates between the 6-month intervention period and the prior 6 months. Primary outcomes were admissions and readmissions due to congestive heart failure, and secondary outcomes were admissions and readmissions due to any cause. Forty-eight patients (96%) completed the protocol. Approximately half (46%) were at high risk for readmission according to standardized measures. Median 120-day adherence was 96% (interquartile range, 92%-98%), and adherence did not significantly differ across sex, race, age, living situation, depression, cognitive ability, or risk for readmission. Approximately equal proportions of patients were admitted for all causes during the 6-month intervention period versus the comparison period (37% vs 43%; P = .32). Half as many patients were admitted for congestive heart failure during the 6-month intervention period compared with the comparison period (12% vs 25%; P = .11). Adherence to this telehealth protocol was excellent and consistent, even among high-risk patients. Future research should test the protocol using a more rigorous randomized design. Copyright © 2017 Elsevier Inc. All rights reserved.
Computational Biology Methods for Characterization of Pluripotent Cells.
Araúzo-Bravo, Marcos J
2016-01-01
Pluripotent cells are a powerful tool for regenerative medicine and drug discovery. Several techniques have been developed to induce pluripotency, or to extract pluripotent cells from different tissues and biological fluids. However, the characterization of pluripotency requires tedious, expensive, time-consuming, and not always reliable wet-lab experiments; thus, an easy, standard quality-control protocol of pluripotency assessment remains to be established. Here to help comes the use of high-throughput techniques, and in particular, the employment of gene expression microarrays, which has become a complementary technique for cellular characterization. Research has shown that the transcriptomics comparison with an Embryonic Stem Cell (ESC) of reference is a good approach to assess the pluripotency. Under the premise that the best protocol is a computer software source code, here I propose and explain line by line a software protocol coded in R-Bioconductor for pluripotency assessment based on the comparison of transcriptomics data of pluripotent cells with an ESC of reference. I provide advice for experimental design, warning about possible pitfalls, and guides for results interpretation.
Jonker, Dirk; Gustafsson, Ewa; Rolander, Bo; Arvidsson, Inger; Nordander, Catarina
2015-01-01
A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k = 0.62) and elbow/hands (84%, k = 0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders. PMID:25761380
Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo
2013-01-01
Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP. PMID:24002231
Tan, Whye Kit; Lee, Sang-Gon; Lam, Jun Huy; Yoo, Seong-Moo
2013-09-02
Wireless mesh networks (WMNs) can act as a scalable backbone by connecting separate sensor networks and even by connecting WMNs to a wired network. The Hybrid Wireless Mesh Protocol (HWMP) is the default routing protocol for the 802.11s WMN. The routing protocol is one of the most important parts of the network, and it requires protection, especially in the wireless environment. The existing security protocols, such as the Broadcast Integrity Protocol (BIP), Counter with cipher block chaining message authentication code protocol (CCMP), Secure Hybrid Wireless Mesh Protocol (SHWMP), Identity Based Cryptography HWMP (IBC-HWMP), Elliptic Curve Digital Signature Algorithm HWMP (ECDSA-HWMP), and Watchdog-HWMP aim to protect the HWMP frames. In this paper, we have analyzed the vulnerabilities of the HWMP and developed security requirements to protect these identified vulnerabilities. We applied the security requirements to analyze the existing secure schemes for HWMP. The results of our analysis indicate that none of these protocols is able to satisfy all of the security requirements. We also present a quantitative complexity comparison among the protocols and an example of a security scheme for HWMP to demonstrate how the result of our research can be utilized. Our research results thus provide a tool for designing secure schemes for the HWMP.
NASA Astrophysics Data System (ADS)
Evans, David J.
2002-11-01
The documentary standards defining internationally adopted methodologies and protocols for calibrating transducers used to measure vibration are currently developed under the International Organization for Standardization (ISO) Technical Committee 108 Sub Committee 3 (Use and calibration of vibration and shock measuring instruments). Recent revisions of the documentary standards on primary methods for the calibration of accelerometers used to measure rectilinear motion have been completed. These standards can be, and have been, used as references in the technical protocols of key international and regional comparisons between National Measurement Institutes (NMIs) on the calibration of accelerometers. These key comparisons are occurring in part as a result of the creation of the Mutual Recognition Arrangement between NMIs which has appendices that document the uncertainties, and the comparisons completed in support of the uncertainties, claimed by the National Laboratories that are signatories of the MRA. The measurements for the first international and the first Interamerican System of Metrology (SIM) regional key comparisons in vibration have been completed. These intercomparisons were promulgated via the relatively new Consultative Committee for Acoustics, Ultrasound and Vibration (CCAUV) of the International Committee for Weights and Measures (CIPM) and SIM Metrology Working Group (MWG) 9, respectively.
Learners' Uses of Two Types of Written Feedback on a L2 Writing Revision Task
ERIC Educational Resources Information Center
Sachs, Rebecca; Polio, Charlene
2007-01-01
This study examines the effectiveness of written error corrections versus reformulations of second language learners' writing as two means of improving learners' grammatical accuracy on a three-stage composition-comparison-revision task. Concurrent verbal protocols were employed during the comparison stage in order to study the learners' reported…
Application of Game Theory Approaches in Routing Protocols for Wireless Networks
NASA Astrophysics Data System (ADS)
Javidi, Mohammad M.; Aliahmadipour, Laya
2011-09-01
An important and essential issue for wireless networks is routing protocol design that is a major technical challenge due to the function of the network. Game theory is a powerful mathematical tool that analyzes the strategic interactions among multiple decision makers and the results of researches show that applied game theory in routing protocol lead to improvement the network performance through reduce overhead and motivates selfish nodes to collaborate in the network. This paper presents a review and comparison for typical representatives of routing protocols designed that applied game theory approaches for various wireless networks such as ad hoc networks, mobile ad hoc networks and sensor networks that all of them lead to improve the network performance.
Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito
2014-01-01
The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.
Aguiar, L. F.; Cunha, G. S. P.; Cardinot, N.; Lucena, E.
2014-01-01
The ovarian stimulation has been applied in order to increase the number of oocytes to compensate for the poor results of in vitro fertilization, allowing the selection of one or more embryos to be transferred. Our aim is to compare the results obtained in IVF/ICSI cycles using the short protocol for controlled ovarian stimulation to the results from the modified mild protocol used in our department. A total of 240 cycles were conducted from January 2010 to December 2011. When comparing both protocols, it could be observed that there was a significant difference in the quantity of gonadotropins doses in the mild protocol and in the short protocol. No significant difference was observed regarding pregnancy rates per cycle, 22% and 26.2%, in short and mild protocols, respectively. The protocols of controlled ovarian stimulation are often associated with high risk of complications such as ovarian hyperstimulation syndrome, excessive emotional stress, high rates of treatment dropouts, and abdominal discomfort. With the data obtained in this study, one can conclude that there are less risks and complications for the patient when using the mild stimulation protocol. It was also observed that in this group there was a slightly higher rate. PMID:25763398
Gabr, Mahmoud M; Zakaria, Mahmoud M; Refaie, Ayman F; Khater, Sherry M; Ashamallah, Sylvia A; Ismail, Amani M; El-Badri, Nagwa; Ghoneim, Mohamed A
2014-01-01
Many protocols were utilized for directed differentiation of mesenchymal stem cells (MSCs) to form insulin-producing cells (IPCs). We compared the relative efficiency of three differentiation protocols. Human bone marrow-derived MSCs (HBM-MSCs) were obtained from three insulin-dependent type 2 diabetic patients. Differentiation into IPCs was carried out by three protocols: conophylline-based (one-step protocol), trichostatin-A-based (two-step protocol), and β -mercaptoethanol-based (three-step protocol). At the end of differentiation, cells were evaluated by immunolabeling for insulin production, expression of pancreatic endocrine genes, and release of insulin and c-peptide in response to increasing glucose concentrations. By immunolabeling, the proportion of generated IPCs was modest ( ≃ 3%) in all the three protocols. All relevant pancreatic endocrine genes, insulin, glucagon, and somatostatin, were expressed. There was a stepwise increase in insulin and c-peptide release in response to glucose challenge, but the released amounts were low when compared with those of pancreatic islets. The yield of functional IPCs following directed differentiation of HBM-MSCs was modest and was comparable among the three tested protocols. Protocols for directed differentiation of MSCs need further optimization in order to be clinically meaningful. To this end, addition of an extracellular matrix and/or a suitable template should be attempted.
Namboodri, Brooke L; Rosen, Tony; Dayaa, Joseph A; Bischof, Jason J; Ramadan, Nadeem; Patel, Mehul D; Grover, Joseph; Brice, Jane H; Platts-Mills, Timothy F
2018-03-22
To describe statewide emergency medical service (EMS) protocols relating to identification, management, and reporting of elder abuse in the prehospital setting. Cross-sectional analysis. Statewide EMS protocols in the United States. Publicly available statewide EMS protocols identified from published literature, http://EMSprotocols.org, and each state's public health website. Protocols were reviewed to determine whether elder abuse was mentioned, elder abuse was defined, potential indicators of elder abuse were listed, management of older adults experiencing abuse was described, and instructions regarding reporting were provided. EMS protocols for child abuse were reviewed in the same manner for the purpose of comparison. Of the 35 publicly available statewide EMS protocols, only 14 (40.0%) mention elder abuse. Of protocols that mention elder abuse, 6 (42.9%) define elder abuse, 10 (71.4%) describe indicators of elder abuse, 8 (57.1%) provide instruction regarding management, and 12 (85.7%) provide instruction regarding reporting. Almost twice as many states met each of these metrics for child abuse. Statewide EMS protocols for elder abuse vary in regard to identification, management, and reporting, with the majority of states having no content on this subject. Expansion and standardization of protocols may increase the identification of elder abuse. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
NASA Astrophysics Data System (ADS)
Shukla, Chitra; Thapliyal, Kishore; Pathak, Anirban
2017-12-01
Semi-quantum protocols that allow some of the users to remain classical are proposed for a large class of problems associated with secure communication and secure multiparty computation. Specifically, first-time semi-quantum protocols are proposed for key agreement, controlled deterministic secure communication and dialogue, and it is shown that the semi-quantum protocols for controlled deterministic secure communication and dialogue can be reduced to semi-quantum protocols for e-commerce and private comparison (socialist millionaire problem), respectively. Complementing with the earlier proposed semi-quantum schemes for key distribution, secret sharing and deterministic secure communication, set of schemes proposed here and subsequent discussions have established that almost every secure communication and computation tasks that can be performed using fully quantum protocols can also be performed in semi-quantum manner. Some of the proposed schemes are completely orthogonal-state-based, and thus, fundamentally different from the existing semi-quantum schemes that are conjugate coding-based. Security, efficiency and applicability of the proposed schemes have been discussed with appropriate importance.
An Efficient Mutual Authentication Framework for Healthcare System in Cloud Computing.
Kumar, Vinod; Jangirala, Srinivas; Ahmad, Musheer
2018-06-28
The increasing role of Telecare Medicine Information Systems (TMIS) makes its accessibility for patients to explore medical treatment, accumulate and approach medical data through internet connectivity. Security and privacy preservation is necessary for medical data of the patient in TMIS because of the very perceptive purpose. Recently, Mohit et al.'s proposed a mutual authentication protocol for TMIS in the cloud computing environment. In this work, we reviewed their protocol and found that it is not secure against stolen verifier attack, many logged in patient attack, patient anonymity, impersonation attack, and fails to protect session key. For enhancement of security level, we proposed a new mutual authentication protocol for the similar environment. The presented framework is also more capable in terms of computation cost. In addition, the security evaluation of the protocol protects resilience of all possible security attributes, and we also explored formal security evaluation based on random oracle model. The performance of the proposed protocol is much better in comparison to the existing protocol.
Auto-Configuration Protocols in Mobile Ad Hoc Networks
Villalba, Luis Javier García; Matesanz, Julián García; Orozco, Ana Lucila Sandoval; Díaz, José Duván Márquez
2011-01-01
The TCP/IP protocol allows the different nodes in a network to communicate by associating a different IP address to each node. In wired or wireless networks with infrastructure, we have a server or node acting as such which correctly assigns IP addresses, but in mobile ad hoc networks there is no such centralized entity capable of carrying out this function. Therefore, a protocol is needed to perform the network configuration automatically and in a dynamic way, which will use all nodes in the network (or part thereof) as if they were servers that manage IP addresses. This article reviews the major proposed auto-configuration protocols for mobile ad hoc networks, with particular emphasis on one of the most recent: D2HCP. This work also includes a comparison of auto-configuration protocols for mobile ad hoc networks by specifying the most relevant metrics, such as a guarantee of uniqueness, overhead, latency, dependency on the routing protocol and uniformity. PMID:22163814
A lightweight and secure two factor anonymous authentication protocol for Global Mobility Networks.
Baig, Ahmed Fraz; Hassan, Khwaja Mansoor Ul; Ghani, Anwar; Chaudhry, Shehzad Ashraf; Khan, Imran; Ashraf, Muhammad Usman
2018-01-01
Global Mobility Networks(GLOMONETs) in wireless communication permits the global roaming services that enable a user to leverage the mobile services in any foreign country. Technological growth in wireless communication is also accompanied by new security threats and challenges. A threat-proof authentication protocol in wireless communication may overcome the security flaws by allowing only legitimate users to access a particular service. Recently, Lee et al. found Mun et al. scheme vulnerable to different attacks and proposed an advanced secure scheme to overcome the security flaws. However, this article points out that Lee et al. scheme lacks user anonymity, inefficient user authentication, vulnerable to replay and DoS attacks and Lack of local password verification. Furthermore, this article presents a more robust anonymous authentication scheme to handle the threats and challenges found in Lee et al.'s protocol. The proposed protocol is formally verified with an automated tool(ProVerif). The proposed protocol has superior efficiency in comparison to the existing protocols.
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks.
Rajeswari, S Raja; Seenivasagam, V
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated.
Enhanced just-in-time plus protocol for optical burst switching networks
NASA Astrophysics Data System (ADS)
Rodrigues, Joel J. P. C.; Gregório, José M. B.; Vasilakos, Athanasios V.
2010-07-01
We propose a new one-way resource reservation protocol for optical burst switching (OBS) networks, called Enhanced Just-in-Time Plus (E-JIT+). The protocol is described in detail, and its formal specification is presented, following an extended finite state machine approach. The performance evaluation of E-JIT+ is analyzed in comparison with other proposed OBS protocols (JIT+ and E-JIT) for the following network topologies: rings; degree-two, degree-three, and degree-four chordal rings; mesh-torus; NSFNET; ARPANET; FCCN-NET; and the European Optical Network. We evaluate and compare the performance of the different protocols in terms of burst loss probability, taking into account the most important OBS network parameters. It was shown that E-JIT+ performs better than available one-way resource reservation protocols for all the evaluated network topologies. Moreover, the scalability of E-JIT+ was observed, and when the network traffic increases, the burst loss probability also increases, leading to a worse network performance.
Comparative Study on Various Authentication Protocols in Wireless Sensor Networks
Rajeswari, S. Raja; Seenivasagam, V.
2016-01-01
Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated. PMID:26881272
A lightweight and secure two factor anonymous authentication protocol for Global Mobility Networks
2018-01-01
Global Mobility Networks(GLOMONETs) in wireless communication permits the global roaming services that enable a user to leverage the mobile services in any foreign country. Technological growth in wireless communication is also accompanied by new security threats and challenges. A threat-proof authentication protocol in wireless communication may overcome the security flaws by allowing only legitimate users to access a particular service. Recently, Lee et al. found Mun et al. scheme vulnerable to different attacks and proposed an advanced secure scheme to overcome the security flaws. However, this article points out that Lee et al. scheme lacks user anonymity, inefficient user authentication, vulnerable to replay and DoS attacks and Lack of local password verification. Furthermore, this article presents a more robust anonymous authentication scheme to handle the threats and challenges found in Lee et al.’s protocol. The proposed protocol is formally verified with an automated tool(ProVerif). The proposed protocol has superior efficiency in comparison to the existing protocols. PMID:29702675
Goldstein, B C; Harris, K C; Klein, M D
1993-02-01
This study investigated the relationship between reading comprehension and oral storytelling abilities. Thirty-one Latino junior high school students with learning handicaps were selected as subjects based on learning handicapped designation, home language, and language proficiency status. Reading comprehension was measured by the Reading Comprehension subtest of the Peabody Individual Achievement Test. Storytelling was measured by (a) the Oral Production subtest of the Language Assessment Scales using the standard scoring protocol and (b) a story structure analysis. A comparison of the standard scoring protocol and reading comprehension revealed no relationship, while the comparison of the story structure analysis and reading comprehension revealed a significant correlation. The implications of these results for language assessment of bilingual students are discussed.
Department of Clinical Investigation Annual Research Progress Report, Fiscal Year 1993. Volume 1
1993-10-01
monocytes, total periphernuclear cells, and alveolar macrophages from four study groups : patients with concurrent Mycobacterium tuberculosis (MTBI and...research design, similar to the Solomon Four Group design will be utilized to determine if the educational intervention provided has an impact on nurses...members with approved protocols: 173 Number of approved protocols held by this group : 230 Drug evaluation/comparison studies : 94 (Does not include
Relative Importance of Different Water Categories as Sources of N-Nitrosamine Precursors.
Zeng, Teng; Glover, Caitlin M; Marti, Erica J; Woods-Chabane, Gwen C; Karanfil, Tanju; Mitch, William A; Dickenson, Eric R V
2016-12-20
A comparison of loadings of N-nitrosamines and their precursors from different source water categories is needed to design effective source water blending strategies. Previous research using Formation Potential (FP) chloramination protocols (high dose and prolonged contact times) raised concerns about precursor loadings from various source water categories, but differences in the protocols employed rendered comparisons difficult. In this study, we applied Uniform Formation Condition (UFC) chloramination and ozonation protocols mimicking typical disinfection practice to compare loadings of ambient specific and total N-nitrosamines as well as chloramine-reactive and ozone-reactive precursors in 47 samples, including 6 pristine headwaters, 16 eutrophic waters, 4 agricultural runoff samples, 9 stormwater runoff samples, and 12 municipal wastewater effluents. N-Nitrosodimethylamine (NDMA) formation from UFC and FP chloramination protocols did not correlate, with NDMA FP often being significant in samples where no NDMA formed under UFC conditions. N-Nitrosamines and their precursors were negligible in pristine headwaters. Conventional, and to a lesser degree, nutrient removal wastewater effluents were the dominant source of NDMA and its chloramine- and ozone-reactive precursors. While wastewater effluents were dominant sources of TONO and their precursors, algal blooms, and to a lesser degree agricultural or stormwater runoff, could be important where they affect a major fraction of the water supply.
Comparison of mild and microdose GnRH agonist flare protocols on IVF outcome in poor responders.
Karimzadeh, Mohammad Ali; Mashayekhy, Mehri; Mohammadian, Farnaz; Moghaddam, Fatemeh Mansoori
2011-05-01
To compare the IVF outcome of clomiphene citrate/gonadotropin/antagonist (mild protocol) and microdose GnRH agonist flare protocols for poor responders undergoing in vitro fertilization. 159 poor responder patients were randomized and ovarian stimulation was performed with clomiphene citrate, gonadotropin and antagonist (group I) or microdose GnRH agonist flare (group II) protocols. Main outcome was clinical pregnancy rate and secondary outcomes were doses of gonadotropin administration and duration of stimulation. There were no significant differences in age, causes of infertility, basal FSH, BMI, duration of infertility, E(2) level on the day of hCG injection in both groups. Although the cancellation, fertilization, and clinical pregnancy rates were similar in both groups, the endometrial thickness, number of retrieved oocytes, mature oocytes and implantation rate were significantly higher in mild protocol. The doses of gonadotropin administration and duration of stimulation were significantly lower in mild protocol. We recommend mild protocol in assisted reproductive technology cycles for poor responders based on our results regarding less doses of used gonadotropin and a shorter duration of stimulation.
Wang, Shang-Lin; Lee, Jih-Jong; Liao, Albert Taiching
2016-01-01
Forty-four dogs with multicentric lymphoma were treated using a cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) induction protocol or treated using a cyclophosphamide, mitoxantrone, vincristine, and prednisolone (CMOP) induction protocol. There was no statistical difference in signalment and the presence of historical negative prognostic factors between the groups. The median progression-free survival (PFS) in the CHOP and CMOP groups were 222 d and 162 d, respectively (P = 0.75). The median survival time (MST) of dogs in CHOP and CMOP groups were 318 d and 242 d, respectively (P = 0.63). Anorexia and diarrhea episodes were significantly higher in the CHOP group than in the CMOP group (P = 0.02 and P = 0.01, respectively). These results suggest that the CMOP protocol provides similar PFS, MST and causes fewer side effects compared to the CHOP protocol. Therefore, the CMOP protocol may be another treatment choice for canine multicentric lymphoma. PMID:26933263
Wang, Shang-Lin; Lee, Jih-Jong; Liao, Albert Taiching
2016-03-01
Forty-four dogs with multicentric lymphoma were treated using a cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) induction protocol or treated using a cyclophosphamide, mitoxantrone, vincristine, and prednisolone (CMOP) induction protocol. There was no statistical difference in signalment and the presence of historical negative prognostic factors between the groups. The median progression-free survival (PFS) in the CHOP and CMOP groups were 222 d and 162 d, respectively (P = 0.75). The median survival time (MST) of dogs in CHOP and CMOP groups were 318 d and 242 d, respectively (P = 0.63). Anorexia and diarrhea episodes were significantly higher in the CHOP group than in the CMOP group (P = 0.02 and P = 0.01, respectively). These results suggest that the CMOP protocol provides similar PFS, MST and causes fewer side effects compared to the CHOP protocol. Therefore, the CMOP protocol may be another treatment choice for canine multicentric lymphoma.
Evaluation of a discharge education protocol for pediatric patients with gastrostomy tubes.
Schweitzer, Michelle; Aucoin, Julia; Docherty, Sharron L; Rice, Henry E; Thompson, Julie; Sullivan, Dori Taylor
2014-01-01
To evaluate the impact of a preprocedure education protocol for children who receive a gastrostomy tube (GT). A preintervention-postintervention design, using surveys and comparison between preprotocol and postprotocol cohorts, was used to evaluate the effect of implementation of a standardized GT education protocol with 26 subjects on caregiver, patient, and provider outcomes. The use of a preprocedure education protocol resulted in improved patient outcomes and increased caregiver knowledge and confidence and was considered a positive change by the providers. Often education is a forgotten part of a medical procedure, and the importance of education is typically only recognized after an adverse event occurs. Establishing a standardized evidence-based education protocol for GT care improves overall care and satisfaction. Use of a systematic and family-centered interdisciplinary approach markedly improves patient care. Copyright © 2014 National Association of Pediatric Nurse Practitioners. Published by Mosby, Inc. All rights reserved.
A protocol for evaluating video trackers under real-world conditions.
Nawaz, Tahir; Cavallaro, Andrea
2013-04-01
The absence of a commonly adopted performance evaluation framework is hampering advances in the design of effective video trackers. In this paper, we present a single-score evaluation measure and a protocol to objectively compare trackers. The proposed measure evaluates tracking accuracy and failure, and combines them for both summative and formative performance assessment. The proposed protocol is composed of a set of trials that evaluate the robustness of trackers on a range of test scenarios representing several real-world conditions. The protocol is validated on a set of sequences with a diversity of targets (head, vehicle and person) and challenges (occlusions, background clutter, pose changes and scale changes) using six state-of-the-art trackers, highlighting their strengths and weaknesses on more than 187000 frames. The software implementing the protocol and the evaluation results are made available online and new results can be included, thus facilitating the comparison of trackers.
Yang, Lei; Chen, Shouming; Yang, Di; Li, Jiajin; Wu, Taixiang; Zuo, Yunxia
2018-05-15
To learn about the overall quality of clinical anaesthesia study protocols from the Chinese Clinical Trials Registry and to discuss the way to improve study protocol quality. We defined completeness of each sub-item in SPIRIT as N/A (not applicable) or with a score of 0, 1, or 2. For each protocol, we calculated the proportion of adequately reported items (score = 2 and N/A) and unreported items (score = 0). Protocol quality was determined according to the proportion of reported items, with values >50% indicating high quality. Protocol quality was determined according to the proportion of reported items. For each sub-item in SPIRIT, we calculated the adequately reported rate (percentage of all protocols with score 2 and NA on one sub-item) as well as the unreported rate (percentage of all protocols with score 0 on one sub-item). Total 126 study protocols were available for assessment. Among these, 88.1% were assessed as being of low quality. By comparison, the percentage of low-quality protocols was 88.9% after the publication of the SPIRIT statement. Among the 51 SPIRIT sub-items, 18 sub-items had an unreported rate above 90% while 16 had a higher adequately reported rate than an unreported rate. The overall quality of clinical anaesthesia study protocols registered in the ChiCTR was poor. A mandatory protocol upload and self-check based on the SPIRIT statement during the trial registration process may improve protocol quality in the future.
Mangold, Stefanie; De Cecco, Carlo N; Wichmann, Julian L; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Fuller, Stephen R; Bamberg, Fabian; Nikolaou, Konstantin; Schoepf, U Joseph
2016-05-01
To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Comparison of H.323 and SIP for IP telephony signaling
NASA Astrophysics Data System (ADS)
Dalgic, Ismail; Fang, Hanlin
1999-11-01
Two standards currently compete for the dominance of IP telephony signaling: the H.323 protocol suite by ITU-T, and the Session Initiation Protocol (SIP) by IETF. Both of these signaling protocols provide mechanisms for call establishment and teardown, call control and supplementary services, and capability exchange. We investigate and compare these two protocols in terms of Functionality, Quality of Service (QoS), Scalability, Flexibility, Interoperability, and Ease of Implementation. For fairness of comparison, we consider similar scenarios for both protocols. In particular, we focus on scenarios that involve a gatekeeper for H.323, and a Proxy/Redirect server for SIP. The reason is that medium-to-large IP Telephony systems are not manageable without a gatekeeper or proxy server. We consider all three versions of H.323. In terms of functionality and services that can be supported, H.323 version 2 and SIP are very similar. However, supplementary services in H.323 are more rigorously defined, and therefore fewer interoperability issues are expected among its implementations. Furthermore, H.323 has taken more steps to ensure compatibility among its different versions, and to interoperate with PSTN. The two protocols are comparable in their QoS support [similar call setup delays, no support for resource reservation or class of service (CoS) setting], but H.323 version 3 will allow signaling of the requested CoS. SIP's primary advantages are (1) flexibility to add new features, and (2) relative ease of implementation and debugging. Finally, we note that H.323 and SIP are improving themselves by learning from each other, and the differences between them are diminishing with each new version.
Zuppa, A A; Alighieri, G; Fracchiolla, A; Catenazzi, P; D'Antuono, A; Riccardi, R; Cavani, M; Romagnoli, C
2012-01-01
[corrected] The Rh-hemolytic disease can lead to a late anemia by hemolytic and hyporigenerative mechanism. We compared the effectiveness of rHuEPO in two care protocols that differ for doses of rHuEPO administrated and for timing of administration. A cohort of 14 neonates was investigated. The neonates were treated with two different protocols. Protocol A: a dose of 200 U/kg/day of rHuEpo administered subcutaneously starting from the end of the second week of life; Protocol B: a dose of 400 U/kg/day of rHuEpo administered subcutaneously starting from the end of the first week of life. The hematocrit values in the protocol A group decreased during treatment (32,5% vs 25,2%), whereas the hematocrit value in protocol B group remained almost stable (38,7% vs 42,8%). The mean numbers of platelets remained stable in both groups while neutrophils increased in protocol A group and decreased in protocol B (p<0,05). Reticulocyte count increased during treatment in both groups, although only in protocol B group it was statistically significative (p<0,05). Our results suggest a similar efficacy between the two treatment protocols. Increasing doses of rHuEPO do not seem enhancing their effectiveness and the incidence of side effects.
A methodological comparison of customer service analysis techniques
James Absher; Alan Graefe; Robert Burns
2003-01-01
Techniques used to analyze customer service data need to be studied. Two primary analysis protocols, importance-performance analysis (IP) and gap score analysis (GA), are compared in a side-by-side comparison using data from two major customer service research projects. A central concern is what, if any, conclusion might be different due solely to the analysis...
A Secure Three-Factor User Authentication and Key Agreement Protocol for TMIS With User Anonymity.
Amin, Ruhul; Biswas, G P
2015-08-01
Telecare medical information system (TMIS) makes an efficient and convenient connection between patient(s)/user(s) and doctor(s) over the insecure internet. Therefore, data security, privacy and user authentication are enormously important for accessing important medical data over insecure communication. Recently, many user authentication protocols for TMIS have been proposed in the literature and it has been observed that most of the protocols cannot achieve complete security requirements. In this paper, we have scrutinized two (Mishra et al., Xu et al.) remote user authentication protocols using smart card and explained that both the protocols are suffering against several security weaknesses. We have then presented three-factor user authentication and key agreement protocol usable for TMIS, which fix the security pitfalls of the above mentioned schemes. The informal cryptanalysis makes certain that the proposed protocol provides well security protection on the relevant security attacks. Furthermore, the simulator AVISPA tool confirms that the protocol is secure against active and passive attacks including replay and man-in-the-middle attacks. The security functionalities and performance comparison analysis confirm that our protocol not only provide strong protection on security attacks, but it also achieves better complexities along with efficient login and password change phase as well as session key verification property.
Carretero, M I; Giuliano, S M; Arraztoa, C C; Santa Cruz, R C; Fumuso, F G; Neild, D M
2017-08-01
Seminal plasma (SP) of South American Camelids could interfere with the interaction of spermatozoa with the extenders; therefore it becomes necessary to improve semen management using enzymatic treatment. Our objective was to compare two cooling protocols for llama semen. Twelve ejaculates were incubated in 0.1% collagenase and then were divided into two aliquots. One was extended in lactose and egg yolk (LEY) (Protocol A: collagenase and SP present). The other aliquot was centrifuged, and the pellet was resuspended in LEY (Protocol B: collagenase and SP absent). Both samples were maintained at 5°C during 24 hr. Routine and DNA evaluations were carried out in raw and cooled semen. Both cooling protocols maintained sperm viability, membrane function and DNA fragmentation, with Protocol A showing a significantly lowered total and progressive motility (p < .05) and Protocol B showing a significant increase in chromatin decondensation (p < .05). Protocol A avoids centrifugation, reducing processing times and making application in the field simpler. However, as neither protocol showed a significant superiority over the other, studies should be carried out in vivo to evaluate the effect on pregnancy rates of the presence of collagenase and SP in semen samples prior to either cooling or freeze-thawing. © 2016 Blackwell Verlag GmbH.
McNair, Helen A; Hansen, Vibeke N; Parker, Christopher C; Evans, Phil M; Norman, Andrew; Miles, Elizabeth; Harris, Emma J; Del-Acroix, Louise; Smith, Elizabeth; Keane, Richard; Khoo, Vincent S; Thompson, Alan C; Dearnaley, David P
2008-05-01
To evaluate the utility of intraprostatic markers in the treatment verification of prostate cancer radiotherapy. Specific aims were: to compare the effectiveness of offline correction protocols, either using gold markers or bony anatomy; to estimate the potential benefit of online correction protocol's using gold markers; to determine the presence and effect of intrafraction motion. Thirty patients with three gold markers inserted had pretreatment and posttreatment images acquired and were treated using an offline correction protocol and gold markers. Retrospectively, an offline protocol was applied using bony anatomy and an online protocol using gold markers. The systematic errors were reduced from 1.3, 1.9, and 2.5 mm to 1.1, 1.1, and 1.5 mm in the right-left (RL), superoinferior (SI), and anteroposterior (AP) directions, respectively, using the offline correction protocol and gold markers instead of bony anatomy. The subsequent decrease in margins was 1.7, 3.3, and 4 mm in the RL, SI, and AP directions, respectively. An offline correction protocol combined with an online correction protocol in the first four fractions reduced random errors further to 0.9, 1.1, and 1.0 mm in the RL, SI, and AP directions, respectively. A daily online protocol reduced all errors to <1 mm. Intrafraction motion had greater impact on the effectiveness of the online protocol than the offline protocols. An offline protocol using gold markers is effective in reducing the systematic error. The value of online protocols is reduced by intrafraction motion.
Using semantics for representing experimental protocols.
Giraldo, Olga; García, Alexander; López, Federico; Corcho, Oscar
2017-11-13
An experimental protocol is a sequence of tasks and operations executed to perform experimental research in biological and biomedical areas, e.g. biology, genetics, immunology, neurosciences, virology. Protocols often include references to equipment, reagents, descriptions of critical steps, troubleshooting and tips, as well as any other information that researchers deem important for facilitating the reusability of the protocol. Although experimental protocols are central to reproducibility, the descriptions are often cursory. There is the need for a unified framework with respect to the syntactic structure and the semantics for representing experimental protocols. In this paper we present "SMART Protocols ontology", an ontology for representing experimental protocols. Our ontology represents the protocol as a workflow with domain specific knowledge embedded within a document. We also present the S ample I nstrument R eagent O bjective (SIRO) model, which represents the minimal common information shared across experimental protocols. SIRO was conceived in the same realm as the Patient Intervention Comparison Outcome (PICO) model that supports search, retrieval and classification purposes in evidence based medicine. We evaluate our approach against a set of competency questions modeled as SPARQL queries and processed against a set of published and unpublished protocols modeled with the SP Ontology and the SIRO model. Our approach makes it possible to answer queries such as Which protocols use tumor tissue as a sample. Improving reporting structures for experimental protocols requires collective efforts from authors, peer reviewers, editors and funding bodies. The SP Ontology is a contribution towards this goal. We build upon previous experiences and bringing together the view of researchers managing protocols in their laboratory work. Website: https://smartprotocols.github.io/ .
Selin, Victor; Ankner, John Francis; Sukhishvili, Svetlana
2018-01-11
Despite intense recent interest in weakly bound nonlinear (“exponential”) multilayers, the underlying structure-property relationships of these films are still poorly understood. This study explores the effect of time used for deposition of individual layers of nonlinearly growing layer-by-layer (LbL) films composed of poly(methacrylic acid) (PMAA) and quaternized poly-2-(dimethylamino)ethyl methacrylate (QPC) on film internal structure, swelling, and stability in salt solution, as well as the rate of penetration of invading polyelectrolyte chains. Thicknesses of dry and swollen films were measured by spectroscopic ellipsometry, film internal structure—by neutron reflectometry (NR), and degree of PMAA ionization—by Fourier-transform infrared spectroscopy (FTIR). The results suggestmore » that longer deposition times resulted in thicker films with higher degrees of swelling (up to swelling ratio as high as 4 compared to dry film thickness) and stronger film intermixing. The stronger intermixed films were more swollen in water, exhibited lower stability in salt solutions, and supported a faster penetration rate of invading polyelectrolyte chains. These results can be useful in designing polyelectrolyte nanoassemblies for biomedical applications, such as drug delivery coatings for medical implants or tissue engineering matrices.« less
Radio-frequency measurement of an asymmetric single electron transistor
NASA Astrophysics Data System (ADS)
Ji, Zhongqing; Xue, Weiwei; Rimberg, A. J.
2007-03-01
Since the invention of the radio-frequency single-electron transistor (RF-SET) by Schoelkopf et al.,[1] most measurements have focused on the symmetric single electron transistor. It has been shown, however, that the symmetric SET has a rather low measurement efficiency in its normal working regime.[2][3] Recently, it has been pointed out that an asymmetric SET can be considerably more efficient than a symmetric SET as a quantum amplifier. In this case the measurement efficiency of the asymmetric SET becomes similar to that of the quantum point contact (QPC) detector which can approach the quantum limit. We investigate the asymmetric SET by fabricating Al/AlOx SETs with junction areas 40x40 nm^2 and 40x80nm^2 and total resistance of about 25kφ. The results of RF and DC characterization of such asymmetric SETs will be discussed. [1] R. J. Schoelkopf, P. Wahlgren, A. A. Kozhevnikov, P. Delsing, D. E. Prober, Science, 280, 1242 (1998). [2] A. N. Korotkov, Phys. Rev. B, 63, 085312 (2001); 63, 115403 (2001). [3] D. Mozyrsky, I. Martin, and M. B. Hastings, Phys. Rev. Lett., 92, 018303 (2004). [4] S. A. Gurvitz and G. P. Berman, Phys. Rev. B, 72 , 073303(2005).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selin, Victor; Ankner, John Francis; Sukhishvili, Svetlana
Despite intense recent interest in weakly bound nonlinear (“exponential”) multilayers, the underlying structure-property relationships of these films are still poorly understood. This study explores the effect of time used for deposition of individual layers of nonlinearly growing layer-by-layer (LbL) films composed of poly(methacrylic acid) (PMAA) and quaternized poly-2-(dimethylamino)ethyl methacrylate (QPC) on film internal structure, swelling, and stability in salt solution, as well as the rate of penetration of invading polyelectrolyte chains. Thicknesses of dry and swollen films were measured by spectroscopic ellipsometry, film internal structure—by neutron reflectometry (NR), and degree of PMAA ionization—by Fourier-transform infrared spectroscopy (FTIR). The results suggestmore » that longer deposition times resulted in thicker films with higher degrees of swelling (up to swelling ratio as high as 4 compared to dry film thickness) and stronger film intermixing. The stronger intermixed films were more swollen in water, exhibited lower stability in salt solutions, and supported a faster penetration rate of invading polyelectrolyte chains. These results can be useful in designing polyelectrolyte nanoassemblies for biomedical applications, such as drug delivery coatings for medical implants or tissue engineering matrices.« less
Comparison of seven protocols to identify fecal contamination sources using Escherichia coli
Stoeckel, D.M.; Mathes, M.V.; Hyer, K.E.; Hagedorn, C.; Kator, H.; Lukasik, J.; O'Brien, T. L.; Fenger, T.W.; Samadpour, M.; Strickler, K.M.; Wiggins, B.A.
2004-01-01
Microbial source tracking (MST) uses various approaches to classify fecal-indicator microorganisms to source hosts. Reproducibility, accuracy, and robustness of seven phenotypic and genotypic MST protocols were evaluated by use of Escherichia coli from an eight-host library of known-source isolates and a separate, blinded challenge library. In reproducibility tests, measuring each protocol's ability to reclassify blinded replicates, only one (pulsed-field gel electrophoresis; PFGE) correctly classified all test replicates to host species; three protocols classified 48-62% correctly, and the remaining three classified fewer than 25% correctly. In accuracy tests, measuring each protocol's ability to correctly classify new isolates, ribotyping with EcoRI and PvuII approached 100% correct classification but only 6% of isolates were classified; four of the other six protocols (antibiotic resistance analysis, PFGE, and two repetitive-element PCR protocols) achieved better than random accuracy rates when 30-100% of challenge isolates were classified. In robustness tests, measuring each protocol's ability to recognize isolates from nonlibrary hosts, three protocols correctly classified 33-100% of isolates as "unknown origin," whereas four protocols classified all isolates to a source category. A relevance test, summarizing interpretations for a hypothetical water sample containing 30 challenge isolates, indicated that false-positive classifications would hinder interpretations for most protocols. Study results indicate that more representation in known-source libraries and better classification accuracy would be needed before field application. Thorough reliability assessment of classification results is crucial before and during application of MST protocols.
Comparing the biocidal properties of non-thermal plasma sources by reference protocol
NASA Astrophysics Data System (ADS)
Khun, Josef; Jirešová, Jana; Kujalová, Lucie; Hozák, Pavel; Scholtz, Vladimír
2017-10-01
The previously proposed reference protocol enabling easy comparison of biocidal properties of different non-thermal plasma sources has been followed and discussed. For inactivation tests the reference protocol has used spores of Gram positive bacterium Bacillus subtilis (ATCC 6633) deposited on a polycarbonate membrane as reference sample. In this work, biocidal properties of a negative glow corona, positive streamer corona, positive transient spark and cometary discharges are being compared in both open air and closed apparatus. Despite the total number of bacteria surviving 1 h exposure has decreased by up to 7 orders in closed apparatus, in open one, only weak inhibition bactericidal effect has been observed.
Shanks, O.C.; Sivaganesan, M.; Peed, L.; Kelty, C.A.; Blackwood, A.D.; Greene, M.R.; Noble, R.T.; Bushon, R.N.; Stelzer, E.A.; Kinzelman, J.; Anan'Eva, T.; Sinigalliano, C.; Wanless, D.; Griffith, J.; Cao, Y.; Weisberg, S.; Harwood, V.J.; Staley, C.; Oshima, K.H.; Varma, M.; Haugland, R.A.
2012-01-01
The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol. ?? 2011 American Chemical Society.
Shavit, Tal; Agdi, Mohammed; Son, Weon Y; Hasson, Josseph; Dahan, Michael H
2016-08-01
The aim of this study was to compare pregnancy rates and stimulation parameters in patients with diminished ovarian reserve, who were treated with recombinant human luteinizing hormone (r-LH) or menopausal gonadotropins (hMG), as part of a microdose flare protocol. A retrospective cohort study was performed. Comparisons between the group that was stimulated with r-LH plus follicle stimulating hormone (FSH) to those treated with hMG and FSH, were performed. Measurements included: medication doses, number of oocyte collected, number of embryos obtained, pregnancy and clinical pregnancy rates. Patients in the r-LH group (N.=40) had significant higher clinical pregnancy rates (33% vs. 14%; P=0.04) and used lower dose of LH (1938 IU vs. 2807 IU; P=0.02) compared to patients that were stimulated with hMG (N.=39). r-LH may offer advantages for the treatment of diminished ovarian reserve when performing a microdose flare protocol when compared to hMG. Both larger and prospective studies should be carried out to confirm these findings.
Yang, Lei; Chen, Shouming; Yang, Di; Li, Jiajin; Wu, Taixiang; Zuo, Yunxia
2018-01-01
Objective To learn about the overall quality of clinical anaesthesia study protocols from the Chinese Clinical Trials Registry and to discuss the way to improve study protocol quality. Methods We defined completeness of each sub-item in SPIRIT as N/A (not applicable) or with a score of 0, 1, or 2. For each protocol, we calculated the proportion of adequately reported items (score = 2 and N/A) and unreported items (score = 0). Protocol quality was determined according to the proportion of reported items, with values >50% indicating high quality. Protocol quality was determined according to the proportion of reported items. For each sub-item in SPIRIT, we calculated the adequately reported rate (percentage of all protocols with score 2 and NA on one sub-item) as well as the unreported rate (percentage of all protocols with score 0 on one sub-item). Results Total 126 study protocols were available for assessment. Among these, 88.1% were assessed as being of low quality. By comparison, the percentage of low-quality protocols was 88.9% after the publication of the SPIRIT statement. Among the 51 SPIRIT sub-items, 18 sub-items had an unreported rate above 90% while 16 had a higher adequately reported rate than an unreported rate. Conclusions The overall quality of clinical anaesthesia study protocols registered in the ChiCTR was poor. A mandatory protocol upload and self-check based on the SPIRIT statement during the trial registration process may improve protocol quality in the future. PMID:29872509
Schmiegelow, Kjeld; Attarbaschi, Andishe; Barzilai, Shlomit; Escherich, Gabriele; Frandsen, Thomas Leth; Halsey, Christina; Hough, Rachael; Jeha, Sima; Kato, Motohiro; Liang, Der-Cherng; Mikkelsen, Torben Stamm; Möricke, Anja; Niinimäki, Riitta; Piette, Caroline; Putti, Maria Caterina; Raetz, Elizabeth; Silverman, Lewis B; Skinner, Roderick; Tuckuviene, Ruta; van der Sluis, Inge; Zapotocka, Ester
2016-06-01
Although there are high survival rates for children with acute lymphoblastic leukaemia, their outcome is often counterbalanced by the burden of toxic effects. This is because reported frequencies vary widely across studies, partly because of diverse definitions of toxic effects. Using the Delphi method, 15 international childhood acute lymphoblastic leukaemia study groups assessed acute lymphoblastic leukaemia protocols to address toxic effects that were to be considered by the Ponte di Legno working group. 14 acute toxic effects (hypersensitivity to asparaginase, hyperlipidaemia, osteonecrosis, asparaginase-associated pancreatitis, arterial hypertension, posterior reversible encephalopathy syndrome, seizures, depressed level of consciousness, methotrexate-related stroke-like syndrome, peripheral neuropathy, high-dose methotrexate-related nephrotoxicity, sinusoidal obstructive syndrome, thromboembolism, and Pneumocystis jirovecii pneumonia) that are serious but too rare to be addressed comprehensively within any single group, or are deemed to need consensus definitions for reliable incidence comparisons, were selected for assessment. Our results showed that none of the protocols addressed all 14 toxic effects, that no two protocols shared identical definitions of all toxic effects, and that no toxic effect definition was shared by all protocols. Using the Delphi method over three face-to-face plenary meetings, consensus definitions were obtained for all 14 toxic effects. In the overall assessment of outcome of acute lymphoblastic leukaemia treatment, these expert opinion-based definitions will allow reliable comparisons of frequencies and severities of acute toxic effects across treatment protocols, and facilitate international research on cause, guidelines for treatment adaptation, preventive strategies, and development of consensus algorithms for reporting on acute lymphoblastic leukaemia treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Eberlein-König, B; Varga, R; Mempel, M; Darsow, U; Behrendt, H; Ring, J
2006-09-01
Flow cytometric basophil activation tests have been developed as cellular tests for in vitro diagnosis of IgE-mediated reactions. Different activation markers (CD63 or CD203c) with distinct ways of regulation have been used after stimulation with various allergens. It was the aim of the present study to compare basophil activation tests by measuring both CD63 and CD203c upregulation in patients with insect venom allergy. 43 patients with a history of insect venom anaphylaxis were examined. A careful allergy history was taken, and skin tests and determination of specific IgE-antibodies were performed. Basophil activation tests (BAT) using CD63 or CD203c expression were done after stimulation with different concentrations of bee and wasp venom extracts. 25 healthy subjects with negative history of insect venom allergy were studied as controls. The CD203c protocol showed a slightly higher sensitivity than the CD63 protocol (97% vs. 89%) with regard to patients' history. The magnitude of basophil response was higher with CD203c in comparison to CD63 for both insect venoms. Specificity was 100% for the CD63 protocol and 89% for the CD203c protocol with regard to controls with negative history and negative RAST. These results support the reliability of basophil activation tests using either CD63 or CD203c as cellular tests in the in vitro diagnosis of patients with bee or wasp venom allergy with a slightly higher sensitivity for the CD203c protocol.
A scoping review of indirect comparison methods and applications using individual patient data.
Veroniki, Areti Angeliki; Straus, Sharon E; Soobiah, Charlene; Elliott, Meghan J; Tricco, Andrea C
2016-04-27
Several indirect comparison methods, including network meta-analyses (NMAs), using individual patient data (IPD) have been developed to synthesize evidence from a network of trials. Although IPD indirect comparisons are published with increasing frequency in health care literature, there is no guidance on selecting the appropriate methodology and on reporting the methods and results. In this paper we examine the methods and reporting of indirect comparison methods using IPD. We searched MEDLINE, Embase, the Cochrane Library, and CINAHL from inception until October 2014. We included published and unpublished studies reporting a method, application, or review of indirect comparisons using IPD and at least three interventions. We identified 37 papers, including a total of 33 empirical networks. Of these, only 9 (27 %) IPD-NMAs reported the existence of a study protocol, whereas 3 (9 %) studies mentioned that protocols existed without providing a reference. The 33 empirical networks included 24 (73 %) IPD-NMAs and 9 (27 %) matching adjusted indirect comparisons (MAICs). Of the 21 (64 %) networks with at least one closed loop, 19 (90 %) were IPD-NMAs, 13 (68 %) of which evaluated the prerequisite consistency assumption, and only 5 (38 %) of the 13 IPD-NMAs used statistical approaches. The median number of trials included per network was 10 (IQR 4-19) (IPD-NMA: 15 [IQR 8-20]; MAIC: 2 [IQR 3-5]), and the median number of IPD trials included in a network was 3 (IQR 1-9) (IPD-NMA: 6 [IQR 2-11]; MAIC: 2 [IQR 1-2]). Half of the networks (17; 52 %) applied Bayesian hierarchical models (14 one-stage, 1 two-stage, 1 used IPD as an informative prior, 1 unclear-stage), including either IPD alone or with aggregated data (AD). Models for dichotomous and continuous outcomes were available (IPD alone or combined with AD), as were models for time-to-event data (IPD combined with AD). One in three indirect comparison methods modeling IPD adjusted results from different trials to estimate effects as if they had come from the same, randomized, population. Key methodological and reporting elements (e.g., evaluation of consistency, existence of study protocol) were often missing from an indirect comparison paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, David C.; Christophersen, Jon P.; Bennett, Taylor
Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. A change in capacity fade mechanism from linear-with-time to t1/2 was observed when the power density measurement was included in the QC/T 743 testing. The rate of resistance increase was linear with time using both protocols. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depthmore » of discharge and pulse width had a direct effect on estimated cell life. At greater percent depth of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin.« less
Yucel, Oguz; Ekin, Murat; Cengiz, Hüseyin; Zebitay, Ali Galip; Yalcinkaya, Sener; Karahuseyinoglu, Sercin
2014-09-01
To compare the effect of the GnRH antagonist/letrozole/gonadotropin protocol with the microdose GnRH agonist flare-up protocol in poor ovarian responders for intracytoplasmic sperm injection. One hundred twenty-one consecutive patients suspected of having or with a history of poor ovarian response between January 2009 and June 2010, who were undergoing ICSI were enrolled. The microdose flareup (MF) protocol was used in 79 patients and the estradiol + progesterone/letrozole + gonadotropin and GnRH antagonist (EP/ALG) protocol was used in 42 patients. Age of the patients, duration of infertility, basal FSH, the total gonadotropin consumption, duration of stimulation, E2 level on the day of hCG administration, the number of embryo transferred, the fertilization rate, implantation rate, clinical pregnancy rate and the live birth rate were not statistically different (p > 0.05). Only the number of oocytes retrieved was significantly higher in the EP/LGA group (1.7 ± 0.7 versus 2.6 ± 0.6). The EP/LGA protocol has no significant improvement against the microdose flare-up protocol in poor responder patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, David C.; Christophersen, Jon P.; Bennett, Taylor
Two testing protocols, QC/T 743 and those used by the U.S. Advanced Battery Consortium (USABC), were compared using cells based on LiFePO4/graphite chemistry. Differences in the protocols directly affected the data and the performance decline mechanisms deduced from the data. In all cases, the rate of capacity fade was linear with time. Overall, the testing protocols produced very similar data when the testing conditions and metrics used to define performance were similar. The choice of depth of discharge and pulse width had a direct effect on the apparent rate of resistance increased and estimated cell life. At greater percent depthmore » of discharge (%DOD) and pulse width, the estimated life was shorter that at lower %DOD and shorter pulse width. This indicates that cells which were at the end of life based on the USABC protocol were not at end of life based on the QC/T 743 protocol by a large margin. (C) 2016 ELSEVIER B.V. All rights reserved.« less
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNair, Helen A.; Hansen, Vibeke N.; Parker, Christopher
2008-05-01
Purpose: To evaluate the utility of intraprostatic markers in the treatment verification of prostate cancer radiotherapy. Specific aims were: to compare the effectiveness of offline correction protocols, either using gold markers or bony anatomy; to estimate the potential benefit of online correction protocol's using gold markers; to determine the presence and effect of intrafraction motion. Methods and Materials: Thirty patients with three gold markers inserted had pretreatment and posttreatment images acquired and were treated using an offline correction protocol and gold markers. Retrospectively, an offline protocol was applied using bony anatomy and an online protocol using gold markers. Results: Themore » systematic errors were reduced from 1.3, 1.9, and 2.5 mm to 1.1, 1.1, and 1.5 mm in the right-left (RL), superoinferior (SI), and anteroposterior (AP) directions, respectively, using the offline correction protocol and gold markers instead of bony anatomy. The subsequent decrease in margins was 1.7, 3.3, and 4 mm in the RL, SI, and AP directions, respectively. An offline correction protocol combined with an online correction protocol in the first four fractions reduced random errors further to 0.9, 1.1, and 1.0 mm in the RL, SI, and AP directions, respectively. A daily online protocol reduced all errors to <1 mm. Intrafraction motion had greater impact on the effectiveness of the online protocol than the offline protocols. Conclusions: An offline protocol using gold markers is effective in reducing the systematic error. The value of online protocols is reduced by intrafraction motion.« less
Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum
Rothe, H.; Obringer, C.; Manwaring, J.; Avci, C.; Wargniez, W.; Eilstein, J.; Hewitt, N.; Cubberley, R.; Duplan, H.; Lange, D.; Jacques‐Jamin, C.; Klaric, M.; Schepky, A.
2017-01-01
Abstract Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics‐relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration‐depth profile using tape‐stripping (measures KSC/v and DSC/HSC 2, where HSC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of KSC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures KSC/v and DSC/HSC 2, and is based on Fick's laws). KSC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two‐fold higher, and all values were within 10‐fold of each other. Only indirect determination of KSC/v by Protocol 2B was different from the direct measurement of KSC/v by Protocol 2A and Protocol 1 for 7‐EC. The variability of KSC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. DSC/HSC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, KSC/v, and DSC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:28139006
Düzgün, Irem; Baltacı, Gül; Atay, O Ahmet
2011-01-01
In this study, we sought to compare the effects of the slow and accelerated protocols on pain and functional activity level after arthroscopic rotator cuff repair. The study included 29 patients (3 men, 26 women) who underwent arthroscopic repair of stage 2 and 3 rotator cuff tears. Patients were randomized in two groups: the accelerated protocol group (n=13) and slow protocol group (n=16). Patients in the accelerated protocol group participated in a preoperative rehabilitation program for 4-6 weeks. Patients were evaluated preoperatively and for 24 weeks postoperatively. Pain was assessed by visual analog scale, and functional activity level was assessed by The Disabilities of The Arm Shoulder and Hand (DASH) questionnaire. The active range of motion was initiated at week 3 after surgery for the accelerated rehabilitation protocol and at week 6 for the slow protocol. The rehabilitation program was completed by the 8th week with the accelerated protocol and by the 22nd week with the slow protocol. There was no significant difference between the slow and accelerated protocols with regard to pain at rest (p>0.05). However, the accelerated protocol was associated with less pain during activity at weeks 5 and 16, and with less pain at night during week 5 (p<0.05). The accelerated protocol was superior to the slow protocol in terms of functional activity level, as determined by DASH at weeks 8, 12, and 16 after surgery (p<0.05). The accelerated protocol is recommended to physical therapists during rehabilitation after arthroscopic rotator cuff repair to prevent the negative effects of immobilization and to support rapid reintegration to daily living activities.
van Zanten, E; Wisselink, G J; Stoll, S; Alvarez, R; Kooistra-Smid, A M D
2011-02-01
A shortened DNA extraction protocol for the QIAsymphony SP was evaluated by quantitative and qualitative comparison of real-time PCR results of 150 co-extracted stool samples. The average ∆Cycle threshold value for positive pathogenic targets was 0.28 Ct. A consensus of 96.91%, with a correlation coefficient of 0.9880 was recorded. Copyright © 2010 Elsevier B.V. All rights reserved.
Cryptographic Protocol for Comparing Sets without Leaking Them: Applications in Astronomy
NASA Astrophysics Data System (ADS)
McCullough, Peter R.
2011-09-01
We describe a cryptographic protocol for two or more persons to compare individual lists of astronomical objects of interest without leaking them. Cryptographers have long known such protocols; astronomers and other scientists may benefit from them also. We describe some latent opportunities that would be enabled by this protocol. Consider the following scenario: Alice has a set of stars that are candidate hosts of transiting planets. Bob has a similar set. Alice and Bob have a mutual desire to know the intersection of their two lists without revealing them to each other. Alice and Bob can recruit a trusted third party, Josephine, to make the comparison, report the results, and then destroy each list. Limitations of that approach are that 1) Josephine must devote time to make each comparison, 2) Alice and Bob may not know a Josephine that they both can trust, especially if Alice and Bob are from different communities, 3) Josephine may not indeed be trustworthy, 4) a fourth person may wittingly or unwittingly intercept one or both of the lists in Josephine's care, and 5) anticipating those limitations, Alice and Bob may elect not to recruit a Josephine and hence not compare their lists. We describe a variant that overcomes those limitations by A) encrypting the lists prior to transmitting them to Josephine, and B) replacing a human Josephine with a computer website.
Żuk, Magdalena; Pezowicz, Celina
2015-01-01
Objective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. Methods. Four healthy subjects were analysed with both marker sets: an HH marker set and four marker clusters in ISB 6DOF. A navigated pointer was used to indicate the anatomical landmark position in the cluster reference system according to the ISB recommendation. Three gait cycles were selected from the data collected simultaneously for the two marker sets. Results. Two protocols showed good intertrial repeatability, which apart from pelvic rotation did not exceed 2°. The greatest differences between protocols were observed in the transverse plane as well as for knee angles. Knee internal/external rotation revealed the lowest subject-to-subject and interprotocol repeatability and inconsistent patterns for both protocols. Knee range of movement in transverse plane was overestimated for the HH set (the mean is 34°), which could indicate the cross-talk effect. Conclusions. The ISB 6DOF anatomically based protocol enabled full 3D kinematic description of joints according to the current standard with clinically acceptable intertrial repeatability and minimal equipment requirements.
Rassnick, K M; Bailey, D B; Malone, E K; Intile, J L; Kiselow, M A; Flory, A B; Barlow, L L; Balkman, C E; Barnard, S M; Waite, A H
2010-12-01
An L-CHOP protocol with interposed treatments of CCNU and MOPP (L-CHOP-CCNU-MOPP) was evaluated in 66 dogs with stages III-V lymphoma. Results were compared with a historical group of 71 dogs treated with an L-CHOP protocol. Complete remission (CR) rates (85 and 80%, respectively) did not differ significantly between protocols (P = 0.48). First CR duration for dogs treated with L-CHOP-CCNU-MOPP was significantly longer: median, 317 days; 2-year CR rate, 35% versus median, 298 days; 2-year CR rate, 13%, P = 0.05). For the L-CHOP-CCNU-MOPP protocol, dogs in substage-b had a 4.3 times greater hazard of having a relapse than dogs in substage-a (P = 0.002). Frequency of adverse chemotherapy-associated gastrointestinal effects did not differ between protocols (P = 0.77). Neutropenia (primarily after CCNU) occurred more frequently in dogs treated with L-CHOP-CCNU-MOPP (P < 0.001). In summary, the L-CHOP-CCNU-MOPP protocol showed an improved duration of first CR as compared with an L-CHOP protocol, but the relevance of this finding might be subject to clinical judgement. © 2010 Blackwell Publishing Ltd.
Faithful teleportation with partially entangled states
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gour, Gilad
2004-10-01
We write explicitly a general protocol for faithful teleportation of a d-state particle (qudit) via a partially entangled pair of (pure) n-state particles. The classical communication cost (CCC) of the protocol is log{sub 2}(nd) bits, and it is implemented by a projective measurement performed by Alice, and a unitary operator performed by Bob (after receiving from Alice the measurement result). We prove the optimality of our protocol by a comparison with the concentrate and teleport strategy. We also show that if d>n/2, or if there is no residual entanglement left after the faithful teleportation, the CCC of any protocol ismore » at least log{sub 2}(nd) bits. Furthermore, we find a lower bound on the CCC in the process transforming one bipartite state to another by means of local operation and classical communication.« less
Comparison of two progressive treadmill tests in patients with peripheral arterial disease.
Riebe, D; Patterson, R B; Braun, C M
2001-11-01
In a vascular rehabilitation program, 28% of our frail elderly patients are unable to be tested with traditional progressive exercise protocols at program entry due to the high (2.0 miles/h or 3.2 km/h) initial treadmill speeds. The purpose of this investigation was to compare a new progressive treadmill protocol which has a reduced initial speed (1.0 mile/h or 1.6 km/h) to an established protocol performed at 2.0 miles/h (3.2 km/h) to determine the comparability and reproducibility of the new protocol. Eleven patients with arterial claudication performed three symptom-limited exercise tests in random order. Two tests used the new protocol while the remaining trial used the established protocol. Claudication pain was measured using a 5-point scale. Oxygen consumption, heart rate, minute ventilation, respiratory exchange ratio and blood pressure at peak exercise were similar among the three trials. There were strong intraclass correlations for peak oxygen consumption (r = 0.97), onset of claudication (r = 0.96) and maximum walking time (r = 0.98) between the two trials using the new protocol. There was also a significant correlation between the new protocol and the established protocol for peak oxygen consumption (r = 0.90) and maximum walking time (r = 0.89). The new progressive treadmill protocol represents a valid, reliable protocol for patients with arterial claudication. This protocol may be useful for testing patients with a low functional capacity so that clinically appropriate exercise prescriptions can be established and the efficacy of treatments can be determined.
Berker, Bülent; Duvan, Candan İltemir; Kaya, Cemil; Aytaç, Ruşen; Satıroğlu, Hakan
2010-01-01
To determine the potential effect of the ultrashort gonadotropin-releasing hormone (GnRH) agonist/GnRH antagonist protocol versus the microdose GnRH agonist protocol in poor responders undergoing intracytoplasmic sperm injection (ICSI). The patients in the Agonist-Antagonist Group (n=41) were administered the ultrashort GnRH-agonist/ antagonist protocol, while the patients in the Microdose Group (n=41) were stimulated according to the microdose flare-up protocol. The mean number of mature oocytes retrieved was the primary outcome measure. Fertilization rate, implantation rate per embryo and clinical pregnancy rates were secondary outcome measures. There was no differenc between the mean number of mature oocytes retrieved in the two groups. There were also no statistical differences between the two groups in terms of peak serum E2 level, canceled cycles, endometrial thickness on hCG day, number of 2 pronucleus and number of embryos transferred. However, the total gonadotropin consumption and duration of stimulation were significantly higher with the Agonist-Antagonist Group compared with the Microdose Group. The implantation and clinical pregnancy rates were similar between the two groups. Despite the high dose of gonadotropin consumption and longer duration of stimulation with the ultrashort GnRH agonist/ antagonist protocol, it seems that the Agonist-Antagonist Protocol is not inferior to the microdose protocol in poor responders undergoing ICSI.
Comparison of Gluten Extraction Protocols Assessed by LC-MS/MS Analysis.
Fallahbaghery, Azadeh; Zou, Wei; Byrne, Keren; Howitt, Crispin A; Colgrave, Michelle L
2017-04-05
The efficiency of gluten extraction is of critical importance to the results derived from any analytical method for gluten detection and quantitation, whether it employs reagent-based technology (antibodies) or analytical instrumentation (mass spectrometry). If the target proteins are not efficiently extracted, the end result will be an under-estimation in the gluten content posing a health risk to people affected by conditions such as celiac disease (CD) and nonceliac gluten sensitivity (NCGS). Five different extraction protocols were investigated using LC-MRM-MS for their ability to efficiently and reproducibly extract gluten. The rapid and simple "IPA/DTT" protocol and related "two-step" protocol were enriched for gluten proteins, 55/86% (trypsin/chymotrypsin) and 41/68% of all protein identifications, respectively, with both methods showing high reproducibility (CV < 15%). When using multistep protocols, it was critical to examine all fractions, as coextraction of proteins occurred across fractions, with significant levels of proteins existing in unexpected fractions and not all proteins within a particular gluten class behaving the same.
Quantum counterfactual communication without a weak trace
NASA Astrophysics Data System (ADS)
Arvidsson-Shukur, D. R. M.; Barnes, C. H. W.
2016-12-01
The classical theories of communication rely on the assumption that there has to be a flow of particles from Bob to Alice in order for him to send a message to her. We develop a quantum protocol that allows Alice to perceive Bob's message "counterfactually"; that is, without Alice receiving any particles that have interacted with Bob. By utilizing a setup built on results from interaction-free measurements, we outline a communication protocol whereby the information travels in the opposite direction of the emitted particles. In comparison to previous attempts on such protocols, this one is such that a weak measurement at the message source would not leave a weak trace that could be detected by Alice's receiver. While some interaction-free schemes require a large number of carefully aligned beam splitters, our protocol is realizable with two or more beam splitters. We demonstrate this protocol by numerically solving the time-dependent Schrödinger equation for a Hamiltonian that implements this quantum counterfactual phenomenon.
An Enhanced Reservation-Based MAC Protocol for IEEE 802.15.4 Networks
Afonso, José A.; Silva, Helder D.; Macedo, Pedro; Rocha, Luis A.
2011-01-01
The IEEE 802.15.4 Medium Access Control (MAC) protocol is an enabling standard for wireless sensor networks. In order to support applications requiring dedicated bandwidth or bounded delay, it provides a reservation-based scheme named Guaranteed Time Slot (GTS). However, the GTS scheme presents some drawbacks, such as inefficient bandwidth utilization and support to a maximum of only seven devices. This paper presents eLPRT (enhanced Low Power Real Time), a new reservation-based MAC protocol that introduces several performance enhancing features in comparison to the GTS scheme. This MAC protocol builds on top of LPRT (Low Power Real Time) and includes various mechanisms designed to increase data transmission reliability against channel errors, improve bandwidth utilization and increase the number of supported devices. A motion capture system based on inertial and magnetic sensors has been used to validate the protocol. The effectiveness of the performance enhancements introduced by each of the new features is demonstrated through the provision of both simulation and experimental results. PMID:22163826
Multivoxel MR Spectroscopy in Acute Ischemic Stroke:Comparison to the Stroke Protocol MRI
Dani, Krishna A.; An, Li; Henning, Erica C.; Shen, Jun; Warach, Steven
2014-01-01
Background and Purpose Few patients with stroke have been imaged with MR spectroscopy (MRS) within the first few hours after onset. We compared data from current MRI protocols to MRS in subjects with ischemic stroke. Methods MRS was incorporated into the standard clinical MRI stroke protocol for subjects <24 hours after onset. MRI and clinical correlates for the metabolic data from MRS were sought. Results One hundred thirty-six MRS voxels from 32 subjects were analyzed. Lactate preceded the appearance of the lesion on diffusion-weighted imaging in some voxels but in others lagged behind it. Current protocols may predict up to 41% of the variance of MRS metabolites. Serum glucose concentration and time to maximum partially predicted the concentration of all major metabolites. Conclusion MRS may be helpful in acute stroke, especially for lactate detection when perfusion-weighted imaging is unavailable. Current MRI protocols do provide surrogate markers for some indices of metabolic activity. PMID:23091121
Robustness of quantum key distribution with discrete and continuous variables to channel noise
NASA Astrophysics Data System (ADS)
Lasota, Mikołaj; Filip, Radim; Usenko, Vladyslav C.
2017-06-01
We study the robustness of quantum key distribution protocols using discrete or continuous variables to the channel noise. We introduce the model of such noise based on coupling of the signal to a thermal reservoir, typical for continuous-variable quantum key distribution, to the discrete-variable case. Then we perform a comparison of the bounds on the tolerable channel noise between these two kinds of protocols using the same noise parametrization, in the case of implementation which is perfect otherwise. Obtained results show that continuous-variable protocols can exhibit similar robustness to the channel noise when the transmittance of the channel is relatively high. However, for strong loss discrete-variable protocols are superior and can overcome even the infinite-squeezing continuous-variable protocol while using limited nonclassical resources. The requirement on the probability of a single-photon production which would have to be fulfilled by a practical source of photons in order to demonstrate such superiority is feasible thanks to the recent rapid development in this field.
Adiabatic state preparation of stripe phases with strongly magnetic atoms
NASA Astrophysics Data System (ADS)
Mazloom, Azadeh; Vermersch, Benoît; Baranov, Mikhail A.; Dalmonte, Marcello
2017-09-01
We propose a protocol for realizing the stripe phase in two spin models on a two-dimensional square lattice, which can be implemented with strongly magnetic atoms (Cr, Dy, Er, etc.) in optical lattices by encoding spin states into Zeeman sublevels of the ground-state manifold. The protocol is tested with cluster-mean-field time-dependent variational Ansätze, validated by comparison with exact results for small systems, which enable us to simulate the dynamics of systems with up to 64 sites during the state-preparation protocol. This allows us, in particular, to estimate the time required for preparation of the stripe phase with high fidelity under real experimental conditions.
Jeziorowska, Dorota; Fontaine, Vincent; Jouve, Charlène; Villard, Eric; Dussaud, Sébastien; Akbar, David; Letang, Valérie; Cervello, Pauline; Itier, Jean-Michiel; Pruniaux, Marie-Pierre; Hulot, Jean-Sébastien
2017-01-01
Human induced pluripotent stem cells (iPSCs) represent a powerful human model to study cardiac disease in vitro, notably channelopathies and sarcomeric cardiomyopathies. Different protocols for cardiac differentiation of iPSCs have been proposed either based on embroid body formation (3D) or, more recently, on monolayer culture (2D). We performed a direct comparison of the characteristics of the derived cardiomyocytes (iPSC-CMs) on day 27 ± 2 of differentiation between 3D and 2D differentiation protocols with two different Wnt-inhibitors were compared: IWR1 (inhibitor of Wnt response) or IWP2 (inhibitor of Wnt production). We firstly found that the level of Troponin T (TNNT2) expression measured by FACS was significantly higher for both 2D protocols as compared to the 3D protocol. In the three methods, iPSC-CM show sarcomeric structures. However, iPSC-CM generated in 2D protocols constantly displayed larger sarcomere lengths as compared to the 3D protocol. In addition, mRNA and protein analyses reveal higher cTNi to ssTNi ratios in the 2D protocol using IWP2 as compared to both other protocols, indicating a higher sarcomeric maturation. Differentiation of cardiac myocytes with 2D monolayer-based protocols and the use of IWP2 allows the production of higher yield of cardiac myocytes that have more suitable characteristics to study sarcomeric cardiomyopathies. PMID:28587156
Comparison of Physiological and Perceptual Responses Between Continuous and Intermittent Cycling
Brasil, Roxana M.; Barreto, Ana C.; Nogueira, Leandro; Santos, Edil; Novaes, Jefferson S.; Reis, Victor M.
2011-01-01
The present study tested the hypothesis that the exercise protocol (continuous vs. intermittent) would affect the physiological response and the perception of effort during aquatic cycling. Each protocol was divided on four stages. Heart rate, arterial blood pressure, blood lactate concentration, central and peripheral rate of perceived exertion were collected in both protocols in aquatic cycling in 10 women (values are mean ± SD): age=32.8 ± 4.8 years; height=1.62 ± 0.05 cm; body mass=61.60 ± 5.19 kg; estimated body fat=27.13 ± 4.92%. Protocols were compared through two way ANOVA with Scheffé’s post-hoc test and the test of Mann- Whitney for rate of perceived exertion with α=0.05. No systematic and consistent differences in heart rate, arterial blood pressure, double product and blood lactate concentration were found between protocols. On the other hand, central rate of perceived exertion was significantly higher at stage four during continuous protocol compared with intermittent protocol (p=0.01), while the peripheral rate of perceived exertion presented higher values at stages three (p=0.02) and four (p=0.00) in the continuous protocol when compared to the results found in intermittent protocol. These findings suggest that although the aquatic cycling induces similar physiologic demands in both protocols, the rate of perceived exertion may vary according to the continuous vs. intermittent nature of the exercise. PMID:23487483
Quantum key distribution with finite resources: Secret key rates via Renyi entropies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus
A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.
Jahnmatz, Maja; Kesa, Gun; Netterlid, Eva; Buisman, Anne-Marie; Thorstensson, Rigmor; Ahlborg, Niklas
2013-05-31
B-cell responses after infection or vaccination are often measured as serum titers of antigen-specific antibodies. Since this does not address the aspect of memory B-cell activity, it may not give a complete picture of the B-cell response. Analysis of memory B cells by ELISpot is therefore an important complement to conventional serology. B-cell ELISpot was developed more than 25 years ago and many assay protocols/reagents would benefit from optimization. We therefore aimed at developing an optimized B-cell ELISpot for the analysis of vaccine-induced human IgG-secreting memory B cells. A protocol was developed based on new monoclonal antibodies to human IgG and biotin-avidin amplification to increase the sensitivity. After comparison of various compounds commonly used to in vitro-activate memory B cells for ELISpot analysis, the TLR agonist R848 plus interleukin (IL)-2 was selected as the most efficient activator combination. The new protocol was subsequently compared to an established protocol, previously used in vaccine studies, based on polyclonal antibodies without biotin avidin amplification and activation of memory B-cells using a mix of antigen, CpG, IL-2 and IL-10. The new protocol displayed significantly better detection sensitivity, shortened the incubation time needed for the activation of memory B cells and reduced the amount of antigen required for the assay. The functionality of the new protocol was confirmed by analyzing specific memory B cells to five different antigens, induced in a limited number of subjects vaccinated against tetanus, diphtheria and pertussis. The limited number of subjects did not allow for a direct comparison with other vaccine studies. Optimization of the B-cell ELISpot will facilitate an improved analysis of IgG-secreting B cells in vaccine studies. Copyright © 2013 Elsevier B.V. All rights reserved.
A protocol for lifetime energy and environmental impact assessment of building insulation materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S., E-mail: shresthass@ornl.gov; Biswas, Kaushik; Desjarlais, Andre O.
This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist,more » which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined.« less
O’Connell, Dylan P.; Thomas, David H.; Dou, Tai H.; Lamb, James M.; Feingold, Franklin; Low, Daniel A.; Fuld, Matthew K.; Sieren, Jered P.; Sloan, Chelsea M.; Shirk, Melissa A.; Hoffman, Eric A.; Hofmann, Christian
2015-01-01
Purpose: To demonstrate that a “5DCT” technique which utilizes fast helical acquisition yields the same respiratory-gated images as a commercial technique for regular, mechanically produced breathing cycles. Methods: Respiratory-gated images of an anesthetized, mechanically ventilated pig were generated using a Siemens low-pitch helical protocol and 5DCT for a range of breathing rates and amplitudes and with standard and low dose imaging protocols. 5DCT reconstructions were independently evaluated by measuring the distances between tissue positions predicted by a 5D motion model and those measured using deformable registration, as well by reconstructing the originally acquired scans. Discrepancies between the 5DCT and commercial reconstructions were measured using landmark correspondences. Results: The mean distance between model predicted tissue positions and deformably registered tissue positions over the nine datasets was 0.65 ± 0.28 mm. Reconstructions of the original scans were on average accurate to 0.78 ± 0.57 mm. Mean landmark displacement between the commercial and 5DCT images was 1.76 ± 1.25 mm while the maximum lung tissue motion over the breathing cycle had a mean value of 27.2 ± 4.6 mm. An image composed of the average of 30 deformably registered images acquired with a low dose protocol had 6 HU image noise (single standard deviation) in the heart versus 31 HU for the commercial images. Conclusions: An end to end evaluation of the 5DCT technique was conducted through landmark based comparison to breathing gated images acquired with a commercial protocol under highly regular ventilation. The techniques were found to agree to within 2 mm for most respiratory phases and most points in the lung. PMID:26133604
NASA Astrophysics Data System (ADS)
Buckley, J.; Wilkinson, D.; Malaroda, A.; Metcalfe, P.
2017-01-01
Three alternative methodologies to the Computed-Tomography Dose Index for the evaluation of Cone-Beam Computed Tomography dose are compared, the Cone-Beam Dose Index, IAEA Human Health Report No. 5 recommended methodology and the AAPM Task Group 111 recommended methodology. The protocols were evaluated for Pelvis and Thorax scan modes on Varian® On-Board Imager and Truebeam kV XI imaging systems. The weighted planar average dose was highest for the AAPM methodology across all scans, with the CBDI being the second highest overall. A 17.96% and 1.14% decrease from the TG-111 protocol to the IAEA and CBDI protocols for the Pelvis mode and 18.15% and 13.10% decrease for the Thorax mode were observed for the XI system. For the OBI system, the variation was 16.46% and 7.14% for Pelvis mode and 15.93% to the CBDI protocol in Thorax mode respectively.
Self-Configuration and Self-Optimization Process in Heterogeneous Wireless Networks
Guardalben, Lucas; Villalba, Luis Javier García; Buiati, Fábio; Sobral, João Bosco Mangueira; Camponogara, Eduardo
2011-01-01
Self-organization in Wireless Mesh Networks (WMN) is an emergent research area, which is becoming important due to the increasing number of nodes in a network. Consequently, the manual configuration of nodes is either impossible or highly costly. So it is desirable for the nodes to be able to configure themselves. In this paper, we propose an alternative architecture for self-organization of WMN based on Optimized Link State Routing Protocol (OLSR) and the ad hoc on demand distance vector (AODV) routing protocols as well as using the technology of software agents. We argue that the proposed self-optimization and self-configuration modules increase the throughput of network, reduces delay transmission and network load, decreases the traffic of HELLO messages according to network’s scalability. By simulation analysis, we conclude that the self-optimization and self-configuration mechanisms can significantly improve the performance of OLSR and AODV protocols in comparison to the baseline protocols analyzed. PMID:22346584
Self-configuration and self-optimization process in heterogeneous wireless networks.
Guardalben, Lucas; Villalba, Luis Javier García; Buiati, Fábio; Sobral, João Bosco Mangueira; Camponogara, Eduardo
2011-01-01
Self-organization in Wireless Mesh Networks (WMN) is an emergent research area, which is becoming important due to the increasing number of nodes in a network. Consequently, the manual configuration of nodes is either impossible or highly costly. So it is desirable for the nodes to be able to configure themselves. In this paper, we propose an alternative architecture for self-organization of WMN based on Optimized Link State Routing Protocol (OLSR) and the ad hoc on demand distance vector (AODV) routing protocols as well as using the technology of software agents. We argue that the proposed self-optimization and self-configuration modules increase the throughput of network, reduces delay transmission and network load, decreases the traffic of HELLO messages according to network's scalability. By simulation analysis, we conclude that the self-optimization and self-configuration mechanisms can significantly improve the performance of OLSR and AODV protocols in comparison to the baseline protocols analyzed.
A Comprehensive Comparison of Multiparty Secure Additions with Differential Privacy
Goryczka, Slawomir; Xiong, Li
2016-01-01
This paper considers the problem of secure data aggregation (mainly summation) in a distributed setting, while ensuring differential privacy of the result. We study secure multiparty addition protocols using well known security schemes: Shamir’s secret sharing, perturbation-based, and various encryptions. We supplement our study with our new enhanced encryption scheme EFT, which is efficient and fault tolerant. Differential privacy of the final result is achieved by either distributed Laplace or Geometric mechanism (respectively DLPA or DGPA), while approximated differential privacy is achieved by diluted mechanisms. Distributed random noise is generated collectively by all participants, which draw random variables from one of several distributions: Gamma, Gauss, Geometric, or their diluted versions. We introduce a new distributed privacy mechanism with noise drawn from the Laplace distribution, which achieves smaller redundant noise with efficiency. We compare complexity and security characteristics of the protocols with different differential privacy mechanisms and security schemes. More importantly, we implemented all protocols and present an experimental comparison on their performance and scalability in a real distributed environment. Based on the evaluations, we identify our security scheme and Laplace DLPA as the most efficient for secure distributed data aggregation with privacy. PMID:28919841
A Comprehensive Comparison of Multiparty Secure Additions with Differential Privacy.
Goryczka, Slawomir; Xiong, Li
2017-01-01
This paper considers the problem of secure data aggregation (mainly summation) in a distributed setting, while ensuring differential privacy of the result. We study secure multiparty addition protocols using well known security schemes: Shamir's secret sharing, perturbation-based, and various encryptions. We supplement our study with our new enhanced encryption scheme EFT, which is efficient and fault tolerant. Differential privacy of the final result is achieved by either distributed Laplace or Geometric mechanism (respectively DLPA or DGPA), while approximated differential privacy is achieved by diluted mechanisms. Distributed random noise is generated collectively by all participants, which draw random variables from one of several distributions: Gamma, Gauss, Geometric, or their diluted versions. We introduce a new distributed privacy mechanism with noise drawn from the Laplace distribution, which achieves smaller redundant noise with efficiency. We compare complexity and security characteristics of the protocols with different differential privacy mechanisms and security schemes. More importantly, we implemented all protocols and present an experimental comparison on their performance and scalability in a real distributed environment. Based on the evaluations, we identify our security scheme and Laplace DLPA as the most efficient for secure distributed data aggregation with privacy.
Toye, Warren; Das, Ram; Kron, Tomas; Franich, Rick; Johnston, Peter; Duchesne, Gillian
2009-05-01
To develop an in vivo dosimetry based investigative action level relevant for a corrective protocol for HDR brachytherapy boost treatment. The dose delivered to points within the urethra and rectum was measured using TLD in vivo dosimetry in 56 patients. Comparisons between the urethral and rectal measurements and TPS calculations showed differences, which are related to the relative position of the implant and TLD trains, and allowed shifts of implant position relative to the prostate to be estimated. Analysis of rectal dose measurements is consistent with implant movement, which was previously only identified with the urethral data. Shift corrected doses were compared with results from the TPS. Comparison of peak doses to the urethra and rectum has been assessed against the proposed corrective protocol to limit overdosing these critical structures. An initial investigative level of 20% difference between measured and TPS peak dose was established, which corresponds to 1/3 of patients which was practical for the caseload. These patients were assessed resulting in corrective action being applied for one patient. Multiple triggering for selective investigative action is outlined. The use of a single in vivo measurement in the first fraction optimizes patient benefit at acceptable cost.
Braune, S; Sperling, C; Maitz, M F; Steinseifer, U; Clauser, J; Hiebl, B; Krajewski, S; Wendel, H P; Jung, F
2017-10-01
The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols. Copyright © 2017 Elsevier B.V. All rights reserved.
Comparison of inter-trial recovery times for the determination of critical power and W' in cycling.
Karsten, Bettina; Hopker, James; Jobson, Simon A; Baker, Jonathan; Petrigna, Luca; Klose, Andreas; Beedie, Christopher
2017-07-01
Critical Power (CP) and W' are often determined using multi-day testing protocols. To investigate this cumbersome testing method, the purpose of this study was to compare the differences between the conventional use of a 24-h inter-trial recovery time with those of 3 h and 30 min for the determination of CP and W'. 9 moderately trained cyclists performed an incremental test to exhaustion to establish the power output associated with the maximum oxygen uptake (p[Formula: see text] max ), and 3 protocols requiring time-to-exhaustion trials at a constant work-rate performed at 80%, 100% and 105% of p[Formula: see text] max. Design: Protocol A utilised 24-h inter-trial recovery (CP 24 /W' 24 ), protocol B utilised 3-h inter-trial recovery (CP 3 /W' 3 ), and protocol C used 30-min inter-trial recovery period (CP 0.5 /W' 0.5 ). CP and W' were calculated using the inverse time (1/t) versus power (P) relation (P = W'(1/t) + CP). 95% Limits of Agreement between protocol A and B were -9 to 15 W; -7.4 to 7.8 kJ (CP/W') and between protocol A and protocol C they were -27 to 22 W; -7.2 to 15.1 kJ (CP/W'). Compared to criterion protocol A, the average prediction error of protocol B was 2.5% (CP) and 25.6% (W'), whilst for protocol C it was 3.7% (CP) and 32.9% (W'). 3-h and 30-min inter-trial recovery time protocols provide valid methods of determining CP but not W' in cycling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinshaw, J. Louis, E-mail: jhinshaw@uwhealth.or; Littrup, Peter J.; Durick, Nathan
2010-12-15
The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols.more » Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not significantly different from the double freeze-thaw protocol (mean diameter: 1.67 {+-} 0.41 cm vs. 1.66 {+-} 0.21 cm, P = 0.77; area: 2.1 {+-} 0.48 cm{sup 2} vs. 1.99 {+-} 0.62 cm{sup 2}, P = 0.7; and circularity: 0.95 {+-} 0.04 vs. 0.96 {+-} 0.03, P = 0.62, respectively). This study suggests that there may be several advantages of a triple freeze-thaw protocol for pulmonary cryoablation, including earlier identification of the imaging findings associated with the ablation, the promise of a shorter procedure time or larger zones of ablation, and theoretically, more effective cytotoxicity related to the additional freeze-thaw cycle.« less
Zhang, Sheng; Liang, Fei; Li, Wenfeng
2017-11-01
The decision to make protocols of phase III randomized controlled trials (RCTs) publicly accessible by leading journals was a landmark event in clinical trial reporting. Here, we compared primary outcomes defined in protocols with those in publications describing the trials and in trial registration. We identified phase III RCTs published between January 1, 2012, and June 30, 2015, in The New England Journal of Medicine, The Lancet, The Journal of the American Medical Association, and The BMJ with available protocols. Consistency in primary outcomes between protocols and registries (articles) was evaluated. We identified 299 phase III RCTs with available protocols in this analysis. Out of them, 25 trials (8.4%) had some discrepancy for primary outcomes between publications and protocols. Types of discrepancies included protocol-defined primary outcome reported as nonprimary outcome in publication (11 trials, 3.7%), protocol-defined primary outcome omitted in publication (10 trials, 3.3%), new primary outcome introduced in publication (8 trials, 2.7%), protocol-defined nonprimary outcome reported as primary outcome in publication (4 trials, 1.3%), and different timing of assessment of primary outcome (4 trials, 1.3%). Out of trials with discrepancies in primary outcome, 15 trials (60.0%) had discrepancies that favored statistically significant results. Registration could be seen as a valid surrogate of protocol in 237 of 299 trials (79.3%) with regard to primary outcome. Despite unrestricted public access to protocols, selective outcome reporting persists in a small fraction of phase III RCTs. Only studies from four leading journals were included, which may cause selection bias and limit the generalizability of this finding. Copyright © 2017 Elsevier Inc. All rights reserved.
Dong, Feng; Vijayakumar, M; Zhou, Huan-Xiang
2003-07-01
The contributions of electrostatic interactions to the binding stability of barnase and barstar were studied by the Poisson-Boltzmann model with three different protocols: a), the dielectric boundary specified as the van der Waals (vdW) surface of the protein along with a protein dielectric constant (epsilon (p)) of 4; b), the dielectric boundary specified as the molecular (i.e., solvent-exclusion (SE)) surface along with epsilon (p) = 4; and c), "SE + epsilon (p) = 20." The "vdW + epsilon (p) = 4" and "SE + epsilon (p) = 20" protocols predicted an overall electrostatic stabilization whereas the "SE + epsilon (p) = 4" protocol predicted an overall electrostatic destabilization. The "vdW + epsilon (p) = 4" protocol was most consistent with experiment. It quantitatively reproduced the observed effects of 17 mutations neutralizing charged residues lining the binding interface and the measured coupling energies of six charge pairs across the interface and reasonably rationalized the experimental ionic strength and pH dependences of the binding constant. In contrast, the "SE + epsilon (p) = 4" protocol predicted significantly larger coupling energies of charge pairs whereas the "SE + epsilon (p) = 20" protocol did not predict any pH dependence. This study calls for further scrutiny of the different Poisson-Boltzmann protocols and demonstrates potential danger in drawing conclusions on electrostatic contributions based on a particular calculation protocol.
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole. PMID:28121992
A Secure Region-Based Geographic Routing Protocol (SRBGR) for Wireless Sensor Networks.
Adnan, Ali Idarous; Hanapi, Zurina Mohd; Othman, Mohamed; Zukarnain, Zuriati Ahmad
2017-01-01
Due to the lack of dependency for routing initiation and an inadequate allocated sextant on responding messages, the secure geographic routing protocols for Wireless Sensor Networks (WSNs) have attracted considerable attention. However, the existing protocols are more likely to drop packets when legitimate nodes fail to respond to the routing initiation messages while attackers in the allocated sextant manage to respond. Furthermore, these protocols are designed with inefficient collection window and inadequate verification criteria which may lead to a high number of attacker selections. To prevent the failure to find an appropriate relay node and undesirable packet retransmission, this paper presents Secure Region-Based Geographic Routing Protocol (SRBGR) to increase the probability of selecting the appropriate relay node. By extending the allocated sextant and applying different message contention priorities more legitimate nodes can be admitted in the routing process. Moreover, the paper also proposed the bound collection window for a sufficient collection time and verification cost for both attacker identification and isolation. Extensive simulation experiments have been performed to evaluate the performance of the proposed protocol in comparison with other existing protocols. The results demonstrate that SRBGR increases network performance in terms of the packet delivery ratio and isolates attacks such as Sybil and Black hole.
Coleman, Margaret S; Marienau, Karen J; Marano, Nina; Marks, Suzanne M; Cetron, Martin S
2014-01-01
In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. Published by Elsevier Ltd.
Coleman, Margaret S.; Marienau, Karen J.; Marano, Nina; Marks, Suzanne M.; Cetron, Martin S.
2017-01-01
Summary Background In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. Methods A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. Results At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. Conclusion The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. PMID:24262643
Salmon, Paul Matthew; Goode, Natassia; Spiertz, Antje; Thomas, Miles; Grant, Eryn; Clacy, Amanda
2017-06-01
Questions have been raised regarding the impact that providing concurrent verbal protocols has on task performance in various settings; however, there has been little empirical testing of this in road transport. The aim of this study was to examine the impact of providing concurrent verbal protocols on driving performance. Participants drove an instrumented vehicle around a set route, twice whilst providing a concurrent verbal protocol, and twice without. A comparison revealed no differences in behaviour related to speed, braking and steering wheel angle when driving mid-block, but a significant difference in aspects of braking and acceleration at roundabouts. When not providing a verbal protocol, participants were found to brake harder on approach to a roundabout and accelerate more heavily coming out of roundabouts. It is concluded that providing verbal protocols may have a positive effect on braking and accelerating. Practical implications related to driver training and future research are discussed. Practitioner Summary: Verbal protocol analysis is used by ergonomists to understand aspects of cognition and decision-making during complex tasks such as driving and control room operation. This study examines the impact that it has on driving performance, providing evidence to support its continued use in ergonomics applications.
Secure quantum private information retrieval using phase-encoded queries
NASA Astrophysics Data System (ADS)
Olejnik, Lukasz
2011-08-01
We propose a quantum solution to the classical private information retrieval (PIR) problem, which allows one to query a database in a private manner. The protocol offers privacy thresholds and allows the user to obtain information from a database in a way that offers the potential adversary, in this model the database owner, no possibility of deterministically establishing the query contents. This protocol may also be viewed as a solution to the symmetrically private information retrieval problem in that it can offer database security (inability for a querying user to steal its contents). Compared to classical solutions, the protocol offers substantial improvement in terms of communication complexity. In comparison with the recent quantum private queries [Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.100.230502 100, 230502 (2008)] protocol, it is more efficient in terms of communication complexity and the number of rounds, while offering a clear privacy parameter. We discuss the security of the protocol and analyze its strengths and conclude that using this technique makes it challenging to obtain the unconditional (in the information-theoretic sense) privacy degree; nevertheless, in addition to being simple, the protocol still offers a privacy level. The oracle used in the protocol is inspired both by the classical computational PIR solutions as well as the Deutsch-Jozsa oracle.
Secure quantum private information retrieval using phase-encoded queries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olejnik, Lukasz
We propose a quantum solution to the classical private information retrieval (PIR) problem, which allows one to query a database in a private manner. The protocol offers privacy thresholds and allows the user to obtain information from a database in a way that offers the potential adversary, in this model the database owner, no possibility of deterministically establishing the query contents. This protocol may also be viewed as a solution to the symmetrically private information retrieval problem in that it can offer database security (inability for a querying user to steal its contents). Compared to classical solutions, the protocol offersmore » substantial improvement in terms of communication complexity. In comparison with the recent quantum private queries [Phys. Rev. Lett. 100, 230502 (2008)] protocol, it is more efficient in terms of communication complexity and the number of rounds, while offering a clear privacy parameter. We discuss the security of the protocol and analyze its strengths and conclude that using this technique makes it challenging to obtain the unconditional (in the information-theoretic sense) privacy degree; nevertheless, in addition to being simple, the protocol still offers a privacy level. The oracle used in the protocol is inspired both by the classical computational PIR solutions as well as the Deutsch-Jozsa oracle.« less
Zakaria, Golam Abu; Schütte, Wilhelm
2003-01-01
The determination of absorbed dose to water for high-energy photon and electron beams is performed in Germany according to the dosimetry protocol DIN 6800-2 (1997). At an international level, the main protocols used are the AAPM dosimetry protocol TG-51 (1999) and the IAEA Code of Practice TRS-398 (2000). The present paper systematically compares these three dosimetry protocols, and identifies similarities and differences. The investigations were performed using 4 and 10 MV photon beams, as well as 6, 8, 9, 10, 12 and 14 MeV electron beams. Two cylindrical and two plane-parallel type chambers were used for measurements. In general, the discrepancies among the three protocols were 1.0% for photon beams and 1.6% for electron beams. Comparative measurements in the context of measurement technical control (MTK) with TLD showed a deviation of less than 1.3% between the measurements obtained according to protocols DIN 6800-2 and MTK (exceptions: 4 MV photons with 2.9% and 6 MeV electrons with 2.4%). While only cylindrical chambers were used for photon beams, measurements of electron beams were performed using both cylindrical and plane-parallel chambers (the latter used after a cross-calibration to a cylindrical chamber, as required by the respective dosimetry protocols). Notably, unlike recommended in the corresponding protocols, we found out that cylindrical chambers can be used also for energies from 6 to 10 MeV.
Berker, Bülent; Duvan, Candan İltemir; Kaya, Cemil; Aytaç, Ruşen; Şatıroğlu, Hakan
2010-01-01
Objective To determine the potential effect of the ultrashort gonadotropin-releasing hormone (GnRH) agonist/GnRH antagonist protocol versus the microdose GnRH agonist protocol in poor responders undergoing intracytoplasmic sperm injection (ICSI). Material and Methods The patients in the Agonist-Antagonist Group (n=41) were administered the ultrashort GnRH-agonist/ antagonist protocol, while the patients in the Microdose Group (n=41) were stimulated according to the microdose flare-up protocol. The mean number of mature oocytes retrieved was the primary outcome measure. Fertilization rate, implantation rate per embryo and clinical pregnancy rates were secondary outcome measures. Results There was no differenc between the mean number of mature oocytes retrieved in the two groups. There were also no statistical differences between the two groups in terms of peak serum E2 level, canceled cycles, endometrial thickness on hCG day, number of 2 pronucleus and number of embryos transferred. However, the total gonadotropin consumption and duration of stimulation were significantly higher with the Agonist-Antagonist Group compared with the Microdose Group. The implantation and clinical pregnancy rates were similar between the two groups. Conclusion Despite the high dose of gonadotropin consumption and longer duration of stimulation with the ultrashort GnRH agonist/ antagonist protocol, it seems that the Agonist-Antagonist Protocol is not inferior to the microdose protocol in poor responders undergoing ICSI. PMID:24591934
Ganry, L; Quilichini, J; Bandini, C M; Leyder, P; Hersant, B; Meningaud, J P
2017-08-01
Very few surgical teams currently use totally independent and free solutions to perform three-dimensional (3D) surgical modelling for osseous free flaps in reconstructive surgery. This study assessed the precision and technical reproducibility of a 3D surgical modelling protocol using free open-source software in mandibular reconstruction with fibula free flaps and surgical guides. Precision was assessed through comparisons of the 3D surgical guide to the sterilized 3D-printed guide, determining accuracy to the millimetre level. Reproducibility was assessed in three surgical cases by volumetric comparison to the millimetre level. For the 3D surgical modelling, a difference of less than 0.1mm was observed. Almost no deformations (<0.2mm) were observed post-autoclave sterilization of the 3D-printed surgical guides. In the three surgical cases, the average precision of fibula free flap modelling was between 0.1mm and 0.4mm, and the average precision of the complete reconstructed mandible was less than 1mm. The open-source software protocol demonstrated high accuracy without complications. However, the precision of the surgical case depends on the surgeon's 3D surgical modelling. Therefore, surgeons need training on the use of this protocol before applying it to surgical cases; this constitutes a limitation. Further studies should address the transfer of expertise. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Shuang; Yin, Zhen-Qiang; Chau, H. F.; Chen, Wei; Wang, Chao; Guo, Guang-Can; Han, Zheng-Fu
2018-04-01
In comparison to qubit-based protocols, qudit-based quantum key distribution ones generally allow two cooperative parties to share unconditionally secure keys under a higher channel noise. However, it is very hard to prepare and measure the required quantum states in qudit-based protocols in general. One exception is the recently proposed highly error tolerant qudit-based protocol known as the Chau15 (Chau 2015 Phys. Rev. A 92 062324). Remarkably, the state preparation and measurement in this protocol can be done relatively easily since the required states are phase encoded almost like the diagonal basis states of a qubit. Here we report the first proof-of-principle demonstration of the Chau15 protocol. One highlight of our experiment is that its post-processing is based on practical one-way manner, while the original proposal in Chau (2015 Phys. Rev. A 92 062324) relies on complicated two-way post-processing, which is a great challenge in experiment. In addition, by manipulating time-bin qudit and measurement with a variable delay interferometer, our realization is extensible to qudit with high-dimensionality and confirms the experimental feasibility of the Chau15 protocol.
Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting.
Fot, Evgenia V; Izotova, Natalia N; Yudina, Angelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y
2017-01-01
The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning ( n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning ( n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO 2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group ( p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.
NASA Astrophysics Data System (ADS)
Jian, Wei; Estevez, Claudio; Chowdhury, Arshad; Jia, Zhensheng; Wang, Jianxin; Yu, Jianguo; Chang, Gee-Kung
2010-12-01
This paper presents an energy-efficient Medium Access Control (MAC) protocol for very-high-throughput millimeter-wave (mm-wave) wireless sensor communication networks (VHT-MSCNs) based on hybrid multiple access techniques of frequency division multiplexing access (FDMA) and time division multiplexing access (TDMA). An energy-efficient Superframe for wireless sensor communication network employing directional mm-wave wireless access technologies is proposed for systems that require very high throughput, such as high definition video signals, for sensing, processing, transmitting, and actuating functions. Energy consumption modeling for each network element and comparisons among various multi-access technologies in term of power and MAC layer operations are investigated for evaluating the energy-efficient improvement of proposed MAC protocol.
Evaluation of Protocol Uniformity Concerning Laparoscopic Cholecystectomy in The Netherlands
Goossens, Richard H. M.; van Eijk, Daan J.; Lange, Johan F.
2008-01-01
Background Iatrogenic bile duct injury remains a current complication of laparoscopic cholecystectomy. One uniform and standardized protocol, based on the “critical view of safety” concept of Strasberg, should reduce the incidence of this complication. Furthermore, owing to the rapid development of minimally invasive surgery, technicians are becoming more frequently involved. To improve communication between the operating team and technicians, standardized actions should also be defined. The aim of this study was to compare existing protocols for laparoscopic cholecystectomy from various Dutch hospitals. Methods Fifteen Dutch hospitals were contacted for evaluation of their protocols for laparoscopic cholecystectomy. All evaluated protocols were divided into six steps and were compared accordingly. Results In total, 13 hospitals responded—5 academic hospitals, 5 teaching hospitals, 3 community hospitals—of which 10 protocols were usable for comparison. Concerning the trocar positions, only minor differences were found. The concept of “critical view of safety” was represented in just one protocol. Furthermore, the order of clipping and cutting the cystic artery and duct differed. Descriptions of instruments and apparatus were also inconsistent. Conclusions Present protocols differ too much to define a universal procedure among surgeons in The Netherlands. The authors propose one (inter)national standardized protocol, including standardized actions. This uniform standardized protocol has to be officially released and recommended by national scientific associations (e.g., the Dutch Society of Surgery) or international societies (e.g., European Association for Endoscopic Surgery and Society of American Gastrointestinal and Endoscopic Surgeons). The aim is to improve patient safety and professional communication, which are necessary for new developments. PMID:18224485
Kim, Chang Rae; Jeon, Ji Young
2018-05-01
The purpose of this article is to compare radiation doses and conspicuity of anatomic landmarks of the temporal bone between the CT technique using spectral beam shaping at 150 kVp with a dedicated tin filter (150 kVp-Sn) and the conventional protocol at 120 kVp. 25 patients (mean age, 46.8 ± 21.2 years) were examined using the 150-kVp Sn protocol (200 reference mAs using automated tube current modulation, 64 × 0.6 mm collimation, 0.6 mm slice thickness, pitch 0.8), whereas 30 patients (mean age, 54.5 ± 17.8 years) underwent the 120-kVp protocol (180 mAs, 128 × 0.6 mm collimation, 0.6 mm slice thickness, pitch 0.8). Radiation doses were compared between the two acquisition techniques, and dosimetric data from the literature were reviewed for comparison of radiation dose reduction. Subjective conspicuity of 23 anatomic landmarks of the temporal bone, expressed by 5-point rating scale and objective conspicuity by signal-to-noise ratio (SNR) which measured in 4 different regions of interest (ROI), were compared between 150-kVp Sn and 120-kVp acquisitions. The mean dose-length-product (DLP) and effective dose were significantly lower for the 150-kVp Sn scans (0.26 ± 0.26 mSv) compared with the 120-kVp scans (0.92 ± 0.10 mSv, p < 0.001). The lowest effective dose from the literature-based protocols was 0.31 ± 0.12 mSv, which proposed as a low-dose protocol in the setting of spiral multislice temporal bone CT. SNR was slightly superior for 120-kVp images, however analyzability of the 23 anatomic structures did not differ significantly between 150-kVp Sn and 120-kVp scans. Temporal bone CT performed at 150 kVp with an additional tin filter for spectral shaping markedly reduced radiation exposure when compared with conventional temporal bone CT at 120 kVp while maintaining anatomic conspicuity. The decreased radiation dose of the 150-kVp Sn was also lower in comparison to the previous literature-based low-dose temporal bone CT protocol. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum.
Rothe, H; Obringer, C; Manwaring, J; Avci, C; Wargniez, W; Eilstein, J; Hewitt, N; Cubberley, R; Duplan, H; Lange, D; Jacques-Jamin, C; Klaric, M; Schepky, A; Grégoire, S
2017-07-01
Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics-relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration-depth profile using tape-stripping (measures K SC/v and D SC /H SC 2 , where H SC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of K SC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures K SC/v and D SC /H SC 2 , and is based on Fick's laws). K SC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were ~two-fold higher, and all values were within 10-fold of each other. Only indirect determination of K SC/v by Protocol 2B was different from the direct measurement of K SC/v by Protocol 2A and Protocol 1 for 7-EC. The variability of K SC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. D SC /H SC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, K SC/v, and D SC values were comparable using different methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd.
Beard, Brian B; Kainz, Wolfgang
2004-10-13
We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head.
Beard, Brian B; Kainz, Wolfgang
2004-01-01
We reviewed articles using computational RF dosimetry to compare the Specific Anthropomorphic Mannequin (SAM) to anatomically correct models of the human head. Published conclusions based on such comparisons have varied widely. We looked for reasons that might cause apparently similar comparisons to produce dissimilar results. We also looked at the information needed to adequately compare the results of computational RF dosimetry studies. We concluded studies were not comparable because of differences in definitions, models, and methodology. Therefore we propose a protocol, developed by an IEEE standards group, as an initial step in alleviating this problem. The protocol calls for a benchmark validation study comparing the SAM phantom to two anatomically correct models of the human head. It also establishes common definitions and reporting requirements that will increase the comparability of all computational RF dosimetry studies of the human head. PMID:15482601
Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli
2011-11-01
The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.
Staub, Gabrielle Marmier; von Overbeck, Jan; Blozik, Eva
2013-09-30
Quality assessment and continuous quality feedback to the staff is crucial for safety and efficiency of teleconsultation and triage. This study evaluates whether it is feasible to use an already existing telephone triage protocol to assess the appropriateness of point-of-care and time-to-treat recommendations after teleconsultations. Based on electronic patient records, we retrospectively compared the point-of-care and time-to-treat recommendations of the paediatric telephone triage protocol with the actual recommendations of trained physicians for children with abdominal pain, following a teleconsultation. In 59 of 96 cases (61%) these recommendations were congruent with the paediatric telephone protocol. Discrepancies were either of organizational nature, due to factors such as local referral policies or gatekeeping insurance models, or of medical origin, such as milder than usual symptoms or clear diagnosis of a minor ailment. A paediatric telephone triage protocol may be applicable in healthcare systems other than the one in which it has been developed, if triage rules are adapted to match the organisational aspects of the local healthcare system.
Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard
2017-10-23
This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.
NASA Astrophysics Data System (ADS)
Sahasrabudhe, Harshad; Fallahi, Saeed; Nakamura, James; Povolotskyi, Michael; Novakovic, Bozidar; Rahman, Rajib; Manfra, Michael; Klimeck, Gerhard
Quantum Point Contacts (QPCs) are extensively used in semiconductor devices for charge sensing, tunneling and interference experiments. Fabry-Pérot interferometers containing 2 QPCs have applications in quantum computing, in which electrons/quasi-particles undergo interference due to back-scattering from the QPCs. Such experiments have turned out to be difficult because of the complex structure of edge states near the QPC boundary. We present realistic simulations of the edge states in QPCs based on GaAs/AlGaAs heterostructures, which can be used to predict conductance and edge state velocities. Conduction band profile is obtained by solving decoupled effective mass Schrödinger and Poisson equations self-consistently on a finite element mesh of a realistic geometry. In the integer quantum Hall regime, we obtain compressible and in-compressible regions near the edges. We then use the recursive Green`s function algorithm to solve Schrödinger equation with open boundary conditions for calculating transmission and local current density in the QPCs. Impurities are treated by inserting bumps in the potential with a Gaussian distribution. We compare observables with experiments for fitting some adjustable parameters. The authors would like to thank Purdue Research Foundation and Purdue Center for Topological Materials for their support.
Hawley, Philippa Helen; Byeon, Jai Jun
2008-05-01
Constipation is a common and distressing condition in patients with cancer, especially those taking opioid analgesics. Many institutions prevent and treat constipation with titrated laxatives, which is known as a bowel protocol. An effective and well-tolerated bowel protocol is a very important component of cancer care, and there is little evidence on which to base selection of the most appropriate agents. This study compares a protocol of the stimulant laxative sennosides alone with a protocol of sennosides plus the stool softener docusate, in hospitalized patients at an oncology center. The docusate-containing protocol had an initial docusate-only step for patients not taking opioids, and four to six 100-mg capsules of docusate sodium in addition to the sennosides for the rest of the protocol. Thirty patients received the sennosides-only (S) protocol and 30 the sennosides plus docusate (DS) protocol. The efficacy and adverse effects of the protocols were monitored for 5-12 days. The two protocols were used sequentially, creating two cohorts, one on each protocol. Eighty percent of patients were taking oral opioids and 72% were admitted for symptom control/supportive care. Over a total of 488 days of observation it was found that the S protocol produced more bowel movements than the DS protocol, and in the symptom control/supportive care patients this difference was statistically significant (p < 0.05). In the S group admitted for symptom control/supportive care 62.5% had a bowel movement more than 50% of days, as compared with 32% in those receiving the DS protocol. Fifty-seven percent of the DS group required additional interventions (lactulose, suppositories or enemas) compared to 40% in the S group. Cramps were reported equally by 3 (10%) patients in each group. Eight patients (27%) experienced diarrhea in the S group compared to 4 (13%) in the DS group. The addition of the initial docusate-only step and adding docusate 400-600 mg/d to the sennosides did not reduce bowel cramps, and was less effective in inducing laxation than the sennosides-only protocol. Further research into the appropriate use of docusate and into the details of bowel protocol design are required.
Larue, A E; Swider, P; Duru, P; Daviaud, D; Quintard, M; Davit, Y
2018-06-21
Optical imaging techniques for biofilm observation, like laser scanning microscopy, are not applicable when investigating biofilm formation in opaque porous media. X-ray micro-tomography (X-ray CMT) might be an alternative but it finds limitations in similarity of X-ray absorption coefficients for the biofilm and aqueous phases. To overcome this difficulty, barium sulphate was used in Davit et al. (2011) to enable high-resolution 3D imaging of biofilm via X-ray CMT. However, this approach lacks comparison with well-established imaging methods, which are known to capture the fine structures of biofilms, as well as uncertainty quantification. Here, we compare two-photon laser scanning microscopy (TPLSM) images of Pseudomonas Aeruginosa biofilm grown in glass capillaries against X-ray CMT using an improved protocol where barium sulphate is combined with low-gelling temperature agarose to avoid sedimentation. Calibrated phantoms consisting of mono-dispersed fluorescent and X-ray absorbent beads were used to evaluate the uncertainty associated with our protocol along with three different segmentation techniques, namely hysteresis, watershed and region growing, to determine the bias relative to image binarization. Metrics such as volume, 3D surface area and thickness were measured and comparison of both imaging modalities shows that X-ray CMT of biofilm using our protocol yields an accuracy that is comparable and even better in certain respects than TPLSM, even in a nonporous system that is largely favourable to TPLSM. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.
Perfect joint remote state preparation of arbitrary six-qubit cluster-type states
NASA Astrophysics Data System (ADS)
Choudhury, Binayak S.; Samanta, Soumen
2018-07-01
In this paper, a joint remote state preparation protocol, which is applicable to six-qubit cluster states, is presented. The scheme is performed with the help of three quantum channels constituted by eight qubits. A new index of efficiency for JRSP protocols is defined. A comparison is made with the existing similar schemes from which it is concluded that the present scheme utilizes its resources more efficiently. The work is a part of the line of research on transfer and remote preparation of entanglement.
A comparison of two methods for quantifying parasitic nematode fecundity
USDA-ARS?s Scientific Manuscript database
Accurate measures of nematode fecundity can provide important information for investigating parasite life history evolution, transmission potential, and effects on host health. Understanding differences among fecundity assessment protocols and standardizing methods, where possible, will enable compa...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P., E-mail: Eiberg@dadlnet.d; Logager, Vibeke B., E-mail: viloe@heh.regionh.d
The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as wellmore » as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.« less
Nestor, Sean M; Gibson, Erin; Gao, Fu-Qiang; Kiss, Alex; Black, Sandra E
2013-02-01
Hippocampal volumetry derived from structural MRI is increasingly used to delineate regions of interest for functional measurements, assess efficacy in therapeutic trials of Alzheimer's disease (AD) and has been endorsed by the new AD diagnostic guidelines as a radiological marker of disease progression. Unfortunately, morphological heterogeneity in AD can prevent accurate demarcation of the hippocampus. Recent developments in automated volumetry commonly use multi-template fusion driven by expert manual labels, enabling highly accurate and reproducible segmentation in disease and healthy subjects. However, there are several protocols to define the hippocampus anatomically in vivo, and the method used to generate atlases may impact automatic accuracy and sensitivity - particularly in pathologically heterogeneous samples. Here we report a fully automated segmentation technique that provides a robust platform to directly evaluate both technical and biomarker performance in AD among anatomically unique labeling protocols. For the first time we test head-to-head the performance of five common hippocampal labeling protocols for multi-atlas based segmentation, using both the Sunnybrook Longitudinal Dementia Study and the entire Alzheimer's Disease Neuroimaging Initiative 1 (ADNI-1) baseline and 24-month dataset. We based these atlas libraries on the protocols of (Haller et al., 1997; Killiany et al., 1993; Malykhin et al., 2007; Pantel et al., 2000; Pruessner et al., 2000), and a single operator performed all manual tracings to generate de facto "ground truth" labels. All methods distinguished between normal elders, mild cognitive impairment (MCI), and AD in the expected directions, and showed comparable correlations with measures of episodic memory performance. Only more inclusive protocols distinguished between stable MCI and MCI-to-AD converters, and had slightly better associations with episodic memory. Moreover, we demonstrate that protocols including more posterior anatomy and dorsal white matter compartments furnish the best voxel-overlap accuracies (Dice Similarity Coefficient=0.87-0.89), compared to expert manual tracings, and achieve the smallest sample sizes required to power clinical trials in MCI and AD. The greatest distribution of errors was localized to the caudal hippocampus and the alveus-fimbria compartment when these regions were excluded. The definition of the medial body did not significantly alter accuracy among more comprehensive protocols. Voxel-overlap accuracies between automatic and manual labels were lower for the more pathologically heterogeneous Sunnybrook study in comparison to the ADNI-1 sample. Finally, accuracy among protocols appears to significantly differ the most in AD subjects compared to MCI and normal elders. Together, these results suggest that selection of a candidate protocol for fully automatic multi-template based segmentation in AD can influence both segmentation accuracy when compared to expert manual labels and performance as a biomarker in MCI and AD. Copyright © 2012 Elsevier Inc. All rights reserved.
Nestor, Sean M.; Gibson, Erin; Gao, Fu-Qiang; Kiss, Alex; Black, Sandra E.
2012-01-01
Hippocampal volumetry derived from structural MRI is increasingly used to delineate regions of interest for functional measurements, assess efficacy in therapeutic trials of Alzheimer’s disease (AD) and has been endorsed by the new AD diagnostic guidelines as a radiological marker of disease progression. Unfortunately, morphological heterogeneity in AD can prevent accurate demarcation of the hippocampus. Recent developments in automated volumetry commonly use multitemplate fusion driven by expert manual labels, enabling highly accurate and reproducible segmentation in disease and healthy subjects. However, there are several protocols to define the hippocampus anatomically in vivo, and the method used to generate atlases may impact automatic accuracy and sensitivity – particularly in pathologically heterogeneous samples. Here we report a fully automated segmentation technique that provides a robust platform to directly evaluate both technical and biomarker performance in AD among anatomically unique labeling protocols. For the first time we test head-to-head the performance of five common hippocampal labeling protocols for multi-atlas based segmentation, using both the Sunnybrook Longitudinal Dementia Study and the entire Alzheimer’s Disease Neuroimaging Initiative 1 (ADNI-1) baseline and 24-month dataset. We based these atlas libraries on the protocols of (Haller et al., 1997; Killiany et al., 1993; Malykhin et al., 2007; Pantel et al., 2000; Pruessner et al., 2000), and a single operator performed all manual tracings to generate de facto “ground truth” labels. All methods distinguished between normal elders, mild cognitive impairment (MCI), and AD in the expected directions, and showed comparable correlations with measures of episodic memory performance. Only more inclusive protocols distinguished between stable MCI and MCI-to-AD converters, and had slightly better associations with episodic memory. Moreover, we demonstrate that protocols including more posterior anatomy and dorsal white matter compartments furnish the best voxel-overlap accuracies (Dice Similarity Coefficient = 0.87–0.89), compared to expert manual tracings, and achieve the smallest sample sizes required to power clinical trials in MCI and AD. The greatest distribution of errors was localized to the caudal hippocampus and alveus-fimbria compartment when these regions were excluded. The definition of the medial body did not significantly alter accuracy among more comprehensive protocols. Voxel-overlap accuracies between automatic and manual labels were lower for the more pathologically heterogeneous Sunnybrook study in comparison to the ADNI-1 sample. Finally, accuracy among protocols appears to significantly differ the most in AD subjects compared to MCI and normal elders. Together, these results suggest that selection of a candidate protocol for fully automatic multi-template based segmentation in AD can influence both segmentation accuracy when compared to expert manual labels and performance as a biomarker in MCI and AD. PMID:23142652
Meyer, C W; Hill, K D
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.
Meyer, C.W.; Hill, K.D.
2015-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952
Dong, Feng; Vijayakumar, M.; Zhou, Huan-Xiang
2003-01-01
The contributions of electrostatic interactions to the binding stability of barnase and barstar were studied by the Poisson-Boltzmann model with three different protocols: a), the dielectric boundary specified as the van der Waals (vdW) surface of the protein along with a protein dielectric constant (ɛp) of 4; b), the dielectric boundary specified as the molecular (i.e., solvent-exclusion (SE)) surface along with ɛp = 4; and c), “SE + ɛp = 20.” The “vdW + ɛp = 4” and “SE + ɛp = 20” protocols predicted an overall electrostatic stabilization whereas the “SE + ɛp = 4” protocol predicted an overall electrostatic destabilization. The “vdW + ɛp = 4” protocol was most consistent with experiment. It quantitatively reproduced the observed effects of 17 mutations neutralizing charged residues lining the binding interface and the measured coupling energies of six charge pairs across the interface and reasonably rationalized the experimental ionic strength and pH dependences of the binding constant. In contrast, the “SE + ɛp = 4” protocol predicted significantly larger coupling energies of charge pairs whereas the “SE + ɛp = 20” protocol did not predict any pH dependence. This study calls for further scrutiny of the different Poisson-Boltzmann protocols and demonstrates potential danger in drawing conclusions on electrostatic contributions based on a particular calculation protocol. PMID:12829463
Maher, Dermot P; Chen, Lucy; Mao, Jianren
2017-02-01
Intravenous ketamine infusions have been used extensively to treat often-intractable neuropathic pain conditions. Because there are many widely divergent ketamine infusion protocols described in the literature, the variation in these protocols presents a challenge for direct comparison of one protocol with another and in discerning an optimal protocol. Careful examination of the published literature suggests that ketamine infusions can be useful to treat neuropathic pain and that certain characteristics of ketamine infusions may be associated with better clinical outcomes. Increased duration of relief from neuropathic pain is associated with (1) higher total infused doses of ketamine; (2) prolonged infusion durations, although the rate of infusion does not appear to be a factor; and (3) coadministration of adjunct medications such as midazolam and/or clonidine that mitigate some of the unpleasant psychomimetic side effects. However, there are few studies designed to optimize ketamine infusion protocols by defining what an effective infusion protocol entails with regard to a respective neuropathic pain condition. Therefore, despite common clinical practice, the current state of the literature leaves the use of ketamine infusions without meaningful guidance from high-quality comparative evidence. The objectives of this topical review are to (1) analyze the available clinical evidence related to ketamine infusion protocols and (2) call for clinical studies to identify optimal ketamine infusion protocols tailored for individual neuropathic pain conditions. The Oxford Center for Evidence-Based Medicine classification for levels of evidence was used to stratify the grades of clinical recommendation for each infusion variable studied.
Prediction of anaerobic power values from an abbreviated WAnT protocol.
Stickley, Christopher D; Hetzler, Ronald K; Kimura, Iris F
2008-05-01
The traditional 30-second Wingate anaerobic test (WAnT) is a widely used anaerobic power assessment protocol. An abbreviated protocol has been shown to decrease the mild to severe physical discomfort often associated with the WAnT. Therefore, the purpose of this study was to determine whether a 20-second WAnT protocol could be used to accurately predict power values of a standard 30-second WAnT. In 96 college females, anaerobic power variables were assessed using a standard 30-second WAnT protocol. Maximum power values as well as instantaneous power at 10, 15, and 20 seconds were recorded. Based on these results, stepwise regression analysis was performed to determine the accuracy with which mean power, minimum power, 30-second power, and percentage of fatigue for a standard 30-second WAnT could be predicted from values obtained during the first 20 seconds of testing. Mean power values showed the highest level of predictability (R2 = 0.99) from the 20-second values. Minimum power, 30-second power, and percentage of fatigue also showed high levels of predictability (R2 = 0.91, 0.84, and 0.84, respectively) using only values obtained during the first 20 seconds of the protocol. An abbreviated (20-second) WAnT protocol appears to effectively predict results of a standard 30-second WAnT in college-age females, allowing for comparison of data to published norms. A shortened test may allow for a decrease in unwanted side effects associated with the traditional WAnT protocol.
Del-Valle-Soto, Carolina; Mex-Perera, Carlos; Orozco-Lugo, Aldo; Lara, Mauricio; Galván-Tejada, Giselle M; Olmedo, Oscar
2014-12-02
Wireless Sensor Networks deliver valuable information for long periods, then it is desirable to have optimum performance, reduced delays, low overhead, and reliable delivery of information. In this work, proposed metrics that influence energy consumption are used for a performance comparison among our proposed routing protocol, called Multi-Parent Hierarchical (MPH), the well-known protocols for sensor networks, Ad hoc On-Demand Distance Vector (AODV), Dynamic Source Routing (DSR), and Zigbee Tree Routing (ZTR), all of them working with the IEEE 802.15.4 MAC layer. Results show how some communication metrics affect performance, throughput, reliability and energy consumption. It can be concluded that MPH is an efficient protocol since it reaches the best performance against the other three protocols under evaluation, such as 19.3% reduction of packet retransmissions, 26.9% decrease of overhead, and 41.2% improvement on the capacity of the protocol for recovering the topology from failures with respect to AODV protocol. We implemented and tested MPH in a real network of 99 nodes during ten days and analyzed parameters as number of hops, connectivity and delay, in order to validate our Sensors 2014, 14 22812 simulator and obtain reliable results. Moreover, an energy model of CC2530 chip is proposed and used for simulations of the four aforementioned protocols, showing that MPH has 15.9% reduction of energy consumption with respect to AODV, 13.7% versus DSR, and 5% against ZTR.
Step length and individual anaerobic threshold assessment in swimming.
Fernandes, R J; Sousa, M; Machado, L; Vilas-Boas, J P
2011-12-01
Anaerobic threshold is widely used for diagnosis of swimming aerobic endurance but the precise incremental protocols step duration for its assessment is controversial. A physiological and biomechanical comparison between intermittent incremental protocols with different step lengths and a maximal lactate steady state (MLSS) test was conducted. 17 swimmers performed 7×200, 300 and 400 m (30 s and 24 h rest between steps and protocols) in front crawl until exhaustion and an MLSS test. The blood lactate concentration values ([La-]) at individual anaerobic threshold were 2.1±0.1, 2.2±0.2 and 1.8±0.1 mmol.l - 1 in the 200, 300 and 400 m protocols (with significant differences between 300 and 400 m tests), and 2.9±1.2 mmol.l - 1 at MLSS (higher than the incremental protocols); all these values are much lower than the traditional 4 mmol.l - 1 value. The velocities at individual anaerobic threshold obtained in incremental protocols were similar (and highly related) to the MLSS, being considerably lower than the velocity at 4 mmol.l - 1. Stroke rate increased and stroke length decreased throughout the different incremental protocols. It was concluded that it is valid to use intermittent incremental protocols of 200 and 300 m lengths to assess the swimming velocity corresponding to individual anaerobic threshold, the progressive protocols tend to underestimate the [La-] at anaerobic threshold assessed by the MLSS test, and swimmers increase velocity through stroke rate increases. © Georg Thieme Verlag KG Stuttgart · New York.
Energy-Aware RFID Anti-Collision Protocol.
Arjona, Laura; Simon, Hugo Landaluce; Ruiz, Asier Perallos
2018-06-11
The growing interest in mobile devices is transforming wireless identification technologies. Mobile and battery-powered Radio Frequency Identification (RFID) readers, such as hand readers and smart phones, are are becoming increasingly attractive. These RFID readers require energy-efficient anti-collision protocols to minimize the tag collisions and to expand the reader's battery life. Furthermore, there is an increasing interest in RFID sensor networks with a growing number of RFID sensor tags. Thus, RFID application developers must be mindful of tag anti-collision protocols. Energy-efficient protocols involve a low reader energy consumption per tag. This work presents a thorough study of the reader energy consumption per tag and analyzes the main factor that affects this metric: the frame size update strategy. Using the conclusion of this analysis, the anti-collision protocol Energy-Aware Slotted Aloha (EASA) is presented to decrease the energy consumption per tag. The frame size update strategy of EASA is configured to minimize the energy consumption per tag. As a result, EASA presents an energy-aware frame. The performance of the proposed protocol is evaluated and compared with several state of the art Aloha-based anti-collision protocols based on the current RFID standard. Simulation results show that EASA, with an average of 15 mJ consumed per tag identified, achieves a 6% average improvement in the energy consumption per tag in relation to the strategies of the comparison.
A comparison of VO2max and metabolic variables between treadmill running and treadmill skating.
Koepp, Kriston K; Janot, Jeffrey M
2008-03-01
The purpose of this study was to determine differences in VO2max and metabolic variables between treadmill running and treadmill skating. This study also examined VO2max responses during a continuous skating treadmill protocol and a discontinuous skating treadmill protocol. Sixteen male high school hockey players, who had a mean age of 16 +/- 1 years and were of an above-average fitness level, participated in this study. All subjects completed 4 exercise trials: a 1-hour skating treadmill familiarization trial, a treadmill running trial, and 2 randomized skating treadmill trials. Minute ventilation (VE), oxygen consumption VO2), carbon dioxide production VCO2), respiratory exchange ratio (RER), and heart rate were averaged every 15 seconds up to VO2max for each exercise test. The results showed that there was a significant difference (P < 0.05) for VO2max (mL.kg.min) and maximal VCO2 (L.min) between the running treadmill protocol and discontinuous skating treadmill protocol. There was also a significant difference for maximal RER between the discontinuous and continuous skating treadmill protocol and between the discontinuous skating treadmill protocol and running treadmill protocol. In conclusion, the running treadmill elicited a greater VO2max (mL.kg.min) than the skating treadmill did, but when it comes to specificity of ice skating, the skating treadmill may be ideal. Also, there was no significant difference between the discontinuous and continuous skating treadmill protocols. Therefore, a continuous protocol is possible on the skating treadmill without compromising correct skating position and physiologic responses. However, the continuous skating treadmill protocol should undergo validation before other scientists, coaches, and strength and conditioning professionals can apply it correctly.
Neuroimaging paradigms for tonotopic mapping (II): the influence of acquisition protocol.
Langers, Dave R M; Sanchez-Panchuelo, Rosa M; Francis, Susan T; Krumbholz, Katrin; Hall, Deborah A
2014-10-15
Numerous studies on the tonotopic organisation of auditory cortex in humans have employed a wide range of neuroimaging protocols to assess cortical frequency tuning. In the present functional magnetic resonance imaging (fMRI) study, we made a systematic comparison between acquisition protocols with variable levels of interference from acoustic scanner noise. Using sweep stimuli to evoke travelling waves of activation, we measured sound-evoked response signals using sparse, clustered, and continuous imaging protocols that were characterised by inter-scan intervals of 8.8, 2.2, or 0.0 s, respectively. With regard to sensitivity to sound-evoked activation, the sparse and clustered protocols performed similarly, and both detected more activation than the continuous method. Qualitatively, tonotopic maps in activated areas proved highly similar, in the sense that the overall pattern of tonotopic gradients was reproducible across all three protocols. However, quantitatively, we observed substantial reductions in response amplitudes to moderately low stimulus frequencies that coincided with regions of strong energy in the scanner noise spectrum for the clustered and continuous protocols compared to the sparse protocol. At the same time, extreme frequencies became over-represented for these two protocols, and high best frequencies became relatively more abundant. Our results indicate that although all three scanning protocols are suitable to determine the layout of tonotopic fields, an exact quantitative assessment of the representation of various sound frequencies is substantially confounded by the presence of scanner noise. In addition, we noticed anomalous signal dynamics in response to our travelling wave paradigm that suggest that the assessment of frequency-dependent tuning is non-trivially influenced by time-dependent (hemo)dynamics when using sweep stimuli. Copyright © 2014. Published by Elsevier Inc.
Ruberu, Shryamalie R; Liu, Yun-Gang; Wong, Carolyn T; Perera, S Kusum; Langlois, Gregg W; Doucette, Gregory J; Powell, Christine L
2003-01-01
A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California Department of Health Services, which uses a Packard TopCount scintillation counter. Due to differences in the detector arrangement between these 2 counters, markedly different counting efficiencies were exhibited, requiring optimization of the RBA protocol for the TopCount instrument. Precision, accuracy, and sensitivity [limit of detection = 0.2 microg saxitoxin (STX) equiv/100 g shellfish tissue] of the modified protocol were equivalent to those of the original protocol. The RBA robustness and adaptability were demonstrated by an interlaboratory study, in which STX concentrations in shellfish generated by the TopCount were consistent with MicroBeta-derived values. Comparison of STX reference standards obtained from the U.S. Food and Drug Administration and the National Research Council, Canada, showed no observable differences. This study confirms the RBA's value as a rapid, high throughput screen prior to testing by the conventional mouse bioassay (MBA) and its suitability for providing an early warning of increasing PSP toxicity when toxin levels are below the MBA limit of detection.
Barbás, María G; Gallego, Sandra V; Castro, Gonzalo M; Baumeister, Elsa; Kademian, Silvia; De Leon, Juan; Cudolá, Analía
2012-01-01
At the time of influenza A (H1N1) emergency, the WHO responded with remarkable speed by releasing guidelines and a protocol for a real-time RT-PCR assay (rRT-PCR). The aim of the present study was to evalúate the performance of the "Real Time Ready Influenza A/H1N1 Detection Set" (June 2009)-Roche kit in comparison to the CDC reference rRT-PCR protocol. The overall sensitivity of the Roche assay for detection of the Inf A gene in the presence or absence of the H1 gene was 74.5 %. The sensitivity for detecting samples that were only positive for the Inf A gene (absence of the H1 gene) was 53.3 % whereas the sensitivity for H1N1-positive samples (presence of the Inf A gene and any other swine gene) was 76.4 %. The specificity of the assay was 97.1 %. A new version of the kit (November 2009) is now available, and a recent evaluation of its performance showed good sensitivity to detect pandemic H1N1 compared to other molecular assays.
Comparison of electro-fusion and intracytoplasmic nuclear injection methods in pig cloning.
Kurome, Mayuko; Fujimura, Tatsuya; Murakami, Hiroshi; Takahagi, Yoichi; Wako, Naohiro; Ochiai, Takashi; Miyazaki, Koji; Nagashima, Hiroshi
2003-01-01
This paper methodologically compares the electro-fusion (EF) and intracytoplasmic injection (ICI) methods, as well as simultaneous fusion/activation (SA) and delayed activation (DA), in somatic nuclear transfer in pigs using fetal fibroblast cells. Comparison of the remodeling pattern of donor nuclei after nuclear transfer by ICI or EF showed that a high rate (80-100%) of premature chromosome condensation occurred in both cases whether or not Ca2+ was present in the fusion medium. Formation of pseudo-pronuclei tended to be lower for nuclear transfer performed by the ICI method (65% vs. 85-97%, p < 0.05). In vitro developmental potential of nuclear transfer embryos reconstructed with IVM oocytes using the EF method was higher than that of those produced by the ICI method (blastocyst formation: 19 vs. 5%, p < 0.05), and it was not improved using in vivo-matured oocytes as recipient cytoplasts. Embryos produced using SA protocol developed to blastocysts with the same degree of efficiency as those produced under the DA protocol (11 vs. 12%). Use of the EF method in conjunction with SA was shown to be an efficient method for producing cloned pigs based on producing a cloned normal pig fetus. However, subtle differences in nuclear remodeling patterns between the SA and DA protocols may imply variations in their nuclear reprogramming efficiency.
Prazeres, Carlos Eduardo Elias Dos; Magalhães, Tiago Augusto; de Castro Carneiro, Adriano Camargo; Cury, Roberto Caldeira; de Melo Moreira, Valéria; Bello, Juliana Hiromi Silva Matsumoto; Rochitte, Carlos Eduardo
The aim of this study was to compare image quality and radiation dose of coronary computed tomography (CT) angiography performed with dual-source CT scanner using 2 different protocols in patients with atrial fibrillation. Forty-seven patients with AF underwent 2 different acquisition protocols: double high-pitch (DHP) spiral acquisition and retrospective spiral acquisition. The image quality was ranked according to a qualitative score by 2 experts: 1, no evident motion; 2, minimal motion not influencing coronary artery luminal evaluation; and 3, motion with impaired luminal evaluation. A third expert solved any disagreement. A total of 732 segments were evaluated. The DHP group (24 patients, 374 segments) showed more segments classified as score 1 than the retrospective spiral acquisition group (71.3% vs 37.4%). Image quality evaluation agreement was high between observers (κ = 0.8). There was significantly lower radiation exposure for the DHP group (3.65 [1.29] vs 23.57 [10.32] mSv). In this original direct comparison, a DHP spiral protocol for coronary CT angiography acquisition in patients with atrial fibrillation resulted in lower radiation exposure and superior image quality compared with conventional spiral retrospective acquisition.
Aguiar, Lorena Andrade de; Melo, Lauro; de Lacerda de Oliveira, Lívia
2018-04-03
A major drawback of conventional descriptive profile (CDP) in sensory evaluation is the long time spent in panel training. Rapid descriptive methods (RDM) have increased significantly. Some of them have been compared with CDP for validation. In Health Sciences, systematic reviews (SR) are performed to evaluate validation of diagnostic tests in relation to a gold standard method. SR present a well-defined protocol to summarize research evidence and to evaluate the quality of the studies with determined criteria. We adapted SR protocol to evaluate the validation of RDM against CDP as satisfactory procedures to obtain food characterization. We used "Population Intervention Comparison Outcome Study - PICOS" framework to design the research in which "Population" was food/ beverages; "intervention" were RDM, "Comparison" was CDP as gold standard, "Outcome" was the ability of RDM to generate similar descriptive profiles in comparison with CDP and "Studies" was sensory descriptive analyses. The proportion of studies concluding for similarity of the RDM with CDP ranged from 0% to 100%. Low and moderate risk of bias were reached by 87% and 13% of the studies, respectively, supporting the conclusions of SR. RDM with semi-trained assessors and evaluation of individual attributes presented higher percentages of concordance with CDP.
Dyjack, D T; Levine, S P; Holtshouser, J L; Schork, M A
1998-06-01
Numerous manufacturing and service organizations have integrated or are considering integration of their respective occupational health and safety management and audit systems into the International Organization for Standardization-based (ISO) audit-driven Quality Management Systems (ISO 9000) or Environmental Management Systems (ISO 14000) models. Companies considering one of these options will likely need to identify and evaluate several key factors before embarking on such efforts. The purpose of this article is to identify and address the key factors through a case study approach. Qualitative and quantitative comparisons of the key features of the American Industrial Hygiene Association ISO-9001 harmonized Occupational Health and Safety Management System with The Goodyear Tire & Rubber Co. management and audit system were conducted. The comparisons showed that the two management systems and their respective audit protocols, although structured differently, were not substantially statistically dissimilar in content. The authors recommend that future studies continue to evaluate the advantages and disadvantages of various audit protocols. Ideally, these studies would identify those audit outcome measures that can be reliably correlated with health and safety performance.
Comparison of different cooling rates for fibroblast and keratinocyte cryopreservation.
Naaldijk, Yahaira; Friedrich-Stöckigt, Annett; Sethe, Sebastian; Stolzing, Alexandra
2016-10-01
Easy, cost-effective and reliable cryopreservation protocols are crucial for the successful and effective application of tissue engineering. Several different protocols are in use, but no comprehensive comparisons across different machine-based and manual methods have been made. Here, we compare the effects of different cooling rates on the post-thaw survival and proliferative capacity of two basic cell lines for skin tissue engineering fibroblasts and keratinocytes, cultured and frozen in suspension or as a monolayer. We demonstrate that effectiveness of cryopreservation cannot be reliably determined immediately after thawing: the results at this stage were not indicative of cell growth in culture 3 days post-thaw. Cryopreservation of fibroblasts in an adherent state greatly diminishes their subsequent growth potential. This was not observed when freezing in suspension. In keratinocytes, however, adherent freezing is as effective as freezing in suspension, which could lead to significant cost and labour savings in a tissue-engineering environment. The 'optimal' cryopreservation protocol depends on cell type and intended use. Where time, ease and cost are dominant factors, the direct freezing into a nitrogen tank (straight freeze) approach remains a viable method. The most effective solution across the board, as measured by viability 3 days post-thaw, was the commonly used, freezing container method. Where machine-controlled cryopreservation is deemed important for tissue-engineering Good Manufacturing Practice, we present results using a portfolio of different cooling rates, identifying the 'optimal' protocol depending on cell type and culture method. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Grappone, J. M., Jr.; Biggin, A. J.; Barrett, T. J.; Hill, M. J.
2017-12-01
Deep in the Earth, thermodynamic behavior drives the geodynamo and creates the Earth's magnetic field. Determining how the strength of the field, its paleointensity (PI), varies with time, is vital to our understanding of Earth's evolution. Thellier-style paleointensity experiments assume the presence of non-interacting, single domain (SD) magnetic particles, which follow Thellier's laws. Most natural rocks however, contain larger, multi-domain (MD) or interacting single domain (ISD) particles that often violate these laws and cause experiments to fail. Even for samples that pass reliability criteria designed to minimize the impact of MD or ISD grains, different PI techniques can give systematically different estimates, implying violation of Thellier's laws. Our goal is to identify any disparities in PI results that may be explainable by protocol-specific MD and ISD behavior and determine optimum methods to maximize accuracy. Volcanic samples from the Hawai'ian SOH1 borehole previously produced method-dependent PI estimates. Previous studies showed consistently lower PI values when using a microwave (MW) system and the perpendicular method than using the original thermal Thellier-Thellier (OT) technique. However, the data were ambiguous regarding the cause of the discrepancy. The diverging estimates appeared to be either the result of using OT instead of the perpendicular method or the result of using MW protocols instead of thermal protocols. Comparison experiments were conducted using the thermal perpendicular method and microwave OT technique to bridge the gap. Preliminary data generally show that the perpendicular method gives lower estimates than OT for comparable Hlab values. MW estimates are also generally lower than thermal estimates using the same protocol.
A Comparison of Five FMRI Protocols for Mapping Speech Comprehension Systems
Binder, Jeffrey R.; Swanson, Sara J.; Hammeke, Thomas A.; Sabsevitz, David S.
2008-01-01
Aims Many fMRI protocols for localizing speech comprehension have been described, but there has been little quantitative comparison of these methods. We compared five such protocols in terms of areas activated, extent of activation, and lateralization. Methods FMRI BOLD signals were measured in 26 healthy adults during passive listening and active tasks using words and tones. Contrasts were designed to identify speech perception and semantic processing systems. Activation extent and lateralization were quantified by counting activated voxels in each hemisphere for each participant. Results Passive listening to words produced bilateral superior temporal activation. After controlling for pre-linguistic auditory processing, only a small area in the left superior temporal sulcus responded selectively to speech. Active tasks engaged an extensive, bilateral attention and executive processing network. Optimal results (consistent activation and strongly lateralized pattern) were obtained by contrasting an active semantic decision task with a tone decision task. There was striking similarity between the network of brain regions activated by the semantic task and the network of brain regions that showed task-induced deactivation, suggesting that semantic processing occurs during the resting state. Conclusions FMRI protocols for mapping speech comprehension systems differ dramatically in pattern, extent, and lateralization of activation. Brain regions involved in semantic processing were identified only when an active, non-linguistic task was used as a baseline, supporting the notion that semantic processing occurs whenever attentional resources are not controlled. Identification of these lexical-semantic regions is particularly important for predicting language outcome in patients undergoing temporal lobe surgery. PMID:18513352
Li, Jie; Li, Qiyue; Qu, Yugui; Zhao, Baohua
2011-01-01
Conventional MAC protocols for wireless sensor network perform poorly when faced with a delay-tolerant mobile network environment. Characterized by a highly dynamic and sparse topology, poor network connectivity as well as data delay-tolerance, delay-tolerant mobile sensor networks exacerbate the severe power constraints and memory limitations of nodes. This paper proposes an energy-efficient MAC protocol using dynamic queue management (EQ-MAC) for power saving and data queue management. Via data transfers initiated by the target sink and the use of a dynamic queue management strategy based on priority, EQ-MAC effectively avoids untargeted transfers, increases the chance of successful data transmission, and makes useful data reach the target terminal in a timely manner. Experimental results show that EQ-MAC has high energy efficiency in comparison with a conventional MAC protocol. It also achieves a 46% decrease in packet drop probability, 79% increase in system throughput, and 25% decrease in mean packet delay.
Li, Jie; Li, Qiyue; Qu, Yugui; Zhao, Baohua
2011-01-01
Conventional MAC protocols for wireless sensor network perform poorly when faced with a delay-tolerant mobile network environment. Characterized by a highly dynamic and sparse topology, poor network connectivity as well as data delay-tolerance, delay-tolerant mobile sensor networks exacerbate the severe power constraints and memory limitations of nodes. This paper proposes an energy-efficient MAC protocol using dynamic queue management (EQ-MAC) for power saving and data queue management. Via data transfers initiated by the target sink and the use of a dynamic queue management strategy based on priority, EQ-MAC effectively avoids untargeted transfers, increases the chance of successful data transmission, and makes useful data reach the target terminal in a timely manner. Experimental results show that EQ-MAC has high energy efficiency in comparison with a conventional MAC protocol. It also achieves a 46% decrease in packet drop probability, 79% increase in system throughput, and 25% decrease in mean packet delay. PMID:22319385
Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus
2017-01-01
To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.
A smart checkpointing scheme for improving the reliability of clustering routing protocols.
Min, Hong; Jung, Jinman; Kim, Bongjae; Cho, Yookun; Heo, Junyoung; Yi, Sangho; Hong, Jiman
2010-01-01
In wireless sensor networks, system architectures and applications are designed to consider both resource constraints and scalability, because such networks are composed of numerous sensor nodes with various sensors and actuators, small memories, low-power microprocessors, radio modules, and batteries. Clustering routing protocols based on data aggregation schemes aimed at minimizing packet numbers have been proposed to meet these requirements. In clustering routing protocols, the cluster head plays an important role. The cluster head collects data from its member nodes and aggregates the collected data. To improve reliability and reduce recovery latency, we propose a checkpointing scheme for the cluster head. In the proposed scheme, backup nodes monitor and checkpoint the current state of the cluster head periodically. We also derive the checkpointing interval that maximizes reliability while using the same amount of energy consumed by clustering routing protocols that operate without checkpointing. Experimental comparisons with existing non-checkpointing schemes show that our scheme reduces both energy consumption and recovery latency.
Humphreys, Michael K; Panacek, Edward; Green, William; Albers, Elizabeth
2013-03-01
Protocols for determining postmortem submersion interval (PMSI) have long been problematic for forensic investigators due to the wide variety of factors affecting the rate of decomposition of submerged carrion. Likewise, it has been equally problematic for researchers to develop standardized experimental protocols to monitor underwater decomposition without artificially affecting the decomposition rate. This study compares two experimental protocols: (i) underwater in situ evaluation with photographic documentation utilizing the Heaton et al. total aquatic decomposition (TAD) score and (ii) weighing the carrion before and after submersion. Complete forensic necropsies were performed as a control. Perinatal piglets were used as human analogs. The results of this study indicate that in order to objectively measure decomposition over time, the human analog should be examined at depth using the TAD scoring system rather than utilizing a carrion weight evaluation. The acquired TAD score can be used to calculate an approximate PMSI. © 2012 American Academy of Forensic Sciences.
A Smart Checkpointing Scheme for Improving the Reliability of Clustering Routing Protocols
Min, Hong; Jung, Jinman; Kim, Bongjae; Cho, Yookun; Heo, Junyoung; Yi, Sangho; Hong, Jiman
2010-01-01
In wireless sensor networks, system architectures and applications are designed to consider both resource constraints and scalability, because such networks are composed of numerous sensor nodes with various sensors and actuators, small memories, low-power microprocessors, radio modules, and batteries. Clustering routing protocols based on data aggregation schemes aimed at minimizing packet numbers have been proposed to meet these requirements. In clustering routing protocols, the cluster head plays an important role. The cluster head collects data from its member nodes and aggregates the collected data. To improve reliability and reduce recovery latency, we propose a checkpointing scheme for the cluster head. In the proposed scheme, backup nodes monitor and checkpoint the current state of the cluster head periodically. We also derive the checkpointing interval that maximizes reliability while using the same amount of energy consumed by clustering routing protocols that operate without checkpointing. Experimental comparisons with existing non-checkpointing schemes show that our scheme reduces both energy consumption and recovery latency. PMID:22163389
Mamon, J; Green, L; Levine, D M; Gibson, G; Gurley, H T
1987-08-01
This study describes the development and testing of a high blood pressure protocol for use in emergency departments (ED) to enhance detection of those patients appropriate for subsequent referral. The protocol involves two serial blood pressure measurements and a patient interview to determine: 1) previous history of high blood pressure (HBP), 2) treatment in past year for HBP, and 3) usual source of medical care. The accuracy of patient reporting was validated by comparison with the patients' hospital record (reflecting outpatient and inpatient visits). Results indicate that these self-reports have high levels of sensitivity (range 90-100%) and specificity (range 79-96%). Use of the additional patient information increased the sensitivity of the screening protocol in identifying when and where a patient should be referred. Use of this methodology indicates that the protocol is a simple and effective method for HBP screening. The findings also suggest that the ED is an ideal site for screening the "hard-to-reach" hypertensive population.
Cyr, Mireille; Lamb, Michael E
2009-05-01
The study was designed to assess the effectiveness of the flexibly structured NICHD Investigative Interview Protocol for child sexual abuse (CSA) investigative interviews by police officers and mental health workers in Quebec. The NICHD Protocol was designed to operationalize "best practice" guidelines and to help forensic interviewers use open-ended prompts to facilitate free recall by alleged victims. A total of 83 interviews with 3- to 13-year-old alleged victims were matched with 83 interviews conducted by the same interviewers before they were trained to use the Protocol. Interviews were matched with respect to the children's ages, children-perpetrator relationships, and the types and frequency of abuse. Coders categorized each of the prompts used to elicit information about the abuse and tabulated the numbers of new forensically relevant details provided in each response. Interviewers used three times as many open-ended prompts in Protocol interviews than in non-Protocol interviews, whereas use of all other types of questions was halved, and the total number of questions asked decreased by 25%. Protocol-guided interviews yielded more details than comparison interviews. The mean number of details per prompt increased from 3 to 5 details when the Protocol was used. Even with young children, interviewers using the Protocol employed more invitations to elicit forensically relevant details. French-speaking investigators using the NICHD Protocol used open-ended prompts rather than focused questions when interviewing alleged victims. In addition, these interviewers needed fewer questions to get relevant information when using the Protocol. A French version of the NICHD Protocol is now available to police officers and social workers who investigate the alleged sexual abuse of young children in French-speaking countries. This French version allowed trained interviewers to increase the use of invitations and reduce the use of more focused and risky questions. When the number of questions was controlled, more central details and more details in total were obtained in Protocol interviews, because the average prompt elicited more detailed answers in Protocol interviews. However, learning to use the NICHD Protocol required extended training and continued feedback sessions to maintain the high quality of interviewing.
Comparison of 2 intravenous insulin protocols: Glycemia variability in critically ill patients.
Gómez-Garrido, Marta; Rodilla-Fiz, Ana M; Girón-Lacasa, María; Rodríguez-Rubio, Laura; Martínez-Blázquez, Anselmo; Martínez-López, Fernando; Pardo-Ibáñez, María Dolores; Núñez-Marín, Juan M
2017-05-01
Glycemic variability is an independent predictor of mortality in critically ill patients. The objective of this study was to compare two intravenous insulin protocols in critically ill patients regarding the glycemic variability. This was a retrospective observational study performed by reviewing clinical records of patients from a Critical Care Unit for 4 consecutive months. First, a simpler Scale-Based Intravenous Insulin Protocol (SBIIP) was reviewed and later it was compared for the same months of the following year with a Sliding Scale-Based Intravenous Insulin Protocol (SSBIIP). All adult patients admitted to the unit during the referred months were included. Patients in whom the protocol was not adequately followed were excluded. A total of 557 patients were reviewed, of whom they had needed intravenous insulin 73 in the first group and 52 in the second group. Four and two patients were excluded in each group respectively. Glycemic variability for both day 1 (DS1) and total stay (DST) was lower in SSBIIP patients compared to SBIIP patients: SD1 34.88 vs 18.16 and SDT 36.45 vs 23.65 (P<.001). A glycemic management protocol in critically ill patients based on sliding scales decreases glycemic variability. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.
Grace, M; Fletcher, L; Powers, S K; Hughes, M; Coombes, J
1996-12-01
Homogenization of tissue for analysis of bioenergetic enzyme activities is a common practice in studies examining metabolic properties of skeletal muscle adaptation to disease, aging, inactivity or exercise. While numerous homogenization techniques are in use today, limited information exists concerning the efficacy of specific homogenization protocols. Therefore, the purpose of this study was to compare the efficacy of four commonly used approaches to homogenizing skeletal muscle for analysis of bioenergetic enzyme activity. The maximal enzyme activity (Vmax) of citrate synthase (CS) and lactate dehydrogenase (LDH) were measured from homogenous muscle samples (N = 48 per homogenization technique) and used as indicators to determine which protocol had the highest efficacy. The homogenization techniques were: (1) glass-on-glass pestle; (2) a combination of a mechanical blender and a teflon pestle (Potter-Elvehjem); (3) a combination of the mechanical blender and a biological detergent; and (4) the combined use of a mechanical blender and a sonicator. The glass-on-glass pestle homogenization protocol produced significantly higher (P < 0.05) enzyme activities compared to all other protocols for both enzymes. Of the four protocols examined, the data demonstrate that the glass-on-glass pestle homogenization protocol is the technique of choice for studying bioenergetic enzyme activity in skeletal muscle.
Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conover, David R.; Crawford, Alasdair J.; Fuller, Jason
This Protocol provides a set of “best practices” for characterizing energy storage systems (ESSs) and measuring and reporting their performance. It serves as a basis for assessing how an ESS will perform with respect to key performance attributes relevant to different applications. It is intended to provide a valid and accurate basis for the comparison of different ESSs. By achieving the stated purpose, the Protocol will enable more informed decision-making in the selection of ESSs for various stationary applications. The Protocol identifies general information and technical specifications relevant in describing an ESS and also defines a set of test, measurement,more » and evaluation criteria with which to express the performance of ESSs that are intended for energy-intensive and/or power-intensive stationary applications. An ESS includes a storage device, battery management system, and any power conversion systems installed with the storage device. The Protocol is agnostic with respect to the storage technology and the size and rating of the ESS. The Protocol does not apply to single-use storage devices and storage devices that are not coupled with power conversion systems, nor does it address safety, security, or operations and maintenance of ESSs, or provide any pass/fail criteria.« less
Campagne, Fabien
2008-02-29
The evaluation of information retrieval techniques has traditionally relied on human judges to determine which documents are relevant to a query and which are not. This protocol is used in the Text Retrieval Evaluation Conference (TREC), organized annually for the past 15 years, to support the unbiased evaluation of novel information retrieval approaches. The TREC Genomics Track has recently been introduced to measure the performance of information retrieval for biomedical applications. We describe two protocols for evaluating biomedical information retrieval techniques without human relevance judgments. We call these protocols No Title Evaluation (NT Evaluation). The first protocol measures performance for focused searches, where only one relevant document exists for each query. The second protocol measures performance for queries expected to have potentially many relevant documents per query (high-recall searches). Both protocols take advantage of the clear separation of titles and abstracts found in Medline. We compare the performance obtained with these evaluation protocols to results obtained by reusing the relevance judgments produced in the 2004 and 2005 TREC Genomics Track and observe significant correlations between performance rankings generated by our approach and TREC. Spearman's correlation coefficients in the range of 0.79-0.92 are observed comparing bpref measured with NT Evaluation or with TREC evaluations. For comparison, coefficients in the range 0.86-0.94 can be observed when evaluating the same set of methods with data from two independent TREC Genomics Track evaluations. We discuss the advantages of NT Evaluation over the TRels and the data fusion evaluation protocols introduced recently. Our results suggest that the NT Evaluation protocols described here could be used to optimize some search engine parameters before human evaluation. Further research is needed to determine if NT Evaluation or variants of these protocols can fully substitute for human evaluations.
A survey on routing protocols for large-scale wireless sensor networks.
Li, Changle; Zhang, Hanxiao; Hao, Binbin; Li, Jiandong
2011-01-01
With the advances in micro-electronics, wireless sensor devices have been made much smaller and more integrated, and large-scale wireless sensor networks (WSNs) based the cooperation among the significant amount of nodes have become a hot topic. "Large-scale" means mainly large area or high density of a network. Accordingly the routing protocols must scale well to the network scope extension and node density increases. A sensor node is normally energy-limited and cannot be recharged, and thus its energy consumption has a quite significant effect on the scalability of the protocol. To the best of our knowledge, currently the mainstream methods to solve the energy problem in large-scale WSNs are the hierarchical routing protocols. In a hierarchical routing protocol, all the nodes are divided into several groups with different assignment levels. The nodes within the high level are responsible for data aggregation and management work, and the low level nodes for sensing their surroundings and collecting information. The hierarchical routing protocols are proved to be more energy-efficient than flat ones in which all the nodes play the same role, especially in terms of the data aggregation and the flooding of the control packets. With focus on the hierarchical structure, in this paper we provide an insight into routing protocols designed specifically for large-scale WSNs. According to the different objectives, the protocols are generally classified based on different criteria such as control overhead reduction, energy consumption mitigation and energy balance. In order to gain a comprehensive understanding of each protocol, we highlight their innovative ideas, describe the underlying principles in detail and analyze their advantages and disadvantages. Moreover a comparison of each routing protocol is conducted to demonstrate the differences between the protocols in terms of message complexity, memory requirements, localization, data aggregation, clustering manner and other metrics. Finally some open issues in routing protocol design in large-scale wireless sensor networks and conclusions are proposed.
A Survey on Routing Protocols for Large-Scale Wireless Sensor Networks
Li, Changle; Zhang, Hanxiao; Hao, Binbin; Li, Jiandong
2011-01-01
With the advances in micro-electronics, wireless sensor devices have been made much smaller and more integrated, and large-scale wireless sensor networks (WSNs) based the cooperation among the significant amount of nodes have become a hot topic. “Large-scale” means mainly large area or high density of a network. Accordingly the routing protocols must scale well to the network scope extension and node density increases. A sensor node is normally energy-limited and cannot be recharged, and thus its energy consumption has a quite significant effect on the scalability of the protocol. To the best of our knowledge, currently the mainstream methods to solve the energy problem in large-scale WSNs are the hierarchical routing protocols. In a hierarchical routing protocol, all the nodes are divided into several groups with different assignment levels. The nodes within the high level are responsible for data aggregation and management work, and the low level nodes for sensing their surroundings and collecting information. The hierarchical routing protocols are proved to be more energy-efficient than flat ones in which all the nodes play the same role, especially in terms of the data aggregation and the flooding of the control packets. With focus on the hierarchical structure, in this paper we provide an insight into routing protocols designed specifically for large-scale WSNs. According to the different objectives, the protocols are generally classified based on different criteria such as control overhead reduction, energy consumption mitigation and energy balance. In order to gain a comprehensive understanding of each protocol, we highlight their innovative ideas, describe the underlying principles in detail and analyze their advantages and disadvantages. Moreover a comparison of each routing protocol is conducted to demonstrate the differences between the protocols in terms of message complexity, memory requirements, localization, data aggregation, clustering manner and other metrics. Finally some open issues in routing protocol design in large-scale wireless sensor networks and conclusions are proposed. PMID:22163808
Kallet, Richard H; Zhuo, Hanjing; Yip, Vivian; Gomez, Antonio; Lipnick, Michael S
2018-01-01
Spontaneous breathing trials (SBTs) and daily sedation interruptions (DSIs) reduce both the duration of mechanical ventilation and ICU length of stay (LOS). The impact of these practices in patients with ARDS has not previously been reported. We examined whether implementation of SBT/DSI protocols reduce duration of mechanical ventilation and ICU LOS in a retrospective group of subjects with ARDS at a large, urban, level-1 trauma center. All ARDS survivors from 2002 to 2016 ( N = 1,053) were partitioned into 2 groups: 397 in the pre-SBT/DSI group (June 2002-December 2007) and 656 in the post-SBT/DSI group (January 2009-April 2016). Patients from 2008, during the protocol implementation period, were excluded. An additional SBT protocol database (2008-2010) was used to assess the efficacy of SBT in transitioning subjects with ARDS to unassisted breathing. Comparisons were assessed by either unpaired t tests or Mann-Whitney tests. Multiple comparisons were made using either one-way analysis of variance or Kruskal-Wallis and Dunn's tests. Linear regression modeling was used to determine variables independently associated with mechanical ventilation duration and ICU LOS; differences were considered statistically significant when P < .05. Compared to the pre-protocol group, subjects with ARDS managed with SBT/DSI protocols experienced pronounced reductions both in median (IQR) mechanical ventilation duration (14 [6-29] vs 9 [4-17] d, respectively, P < .001) and median ICU LOS (18 [8-33] vs 13 [7-22] d, respectively P < .001). In the final model, only treatment in the SBT/DSI period and higher baseline respiratory system compliance were independently associated with reduced mechanical ventilation duration and ICU LOS. Among subjects with ARDS in the SBT performance database, most achieved unassisted breathing with a median of 2 SBTs. Evidenced-based protocols governing weaning and sedation practices were associated with both reduced mechanical ventilation duration and ICU LOS in subjects with ARDS. However, higher respiratory system compliance in the SBT/DSI cohort also contributed to these improved outcomes. Copyright © 2018 by Daedalus Enterprises.
Recommendations following a multi-laboratory comparison of microbial source tracking methods
Microbial source tracking (MST) methods are under development to provide resource managers with tools to identify sources of fecal contamination in water. Some of the most promising methods currently under development were recently evaluated in the Source Identification Protocol ...
Leaving A Mark: A Comparison Arthropod Protein Marking Protocols
USDA-ARS?s Scientific Manuscript database
Knowledge of arthropod pest and natural enemy disperal patterns is needed for effective and environmentally benign pest control. The most common tactics used to monitor arthropod dispersal patterns include mark-release-recapture (MRR) and mark-capture methodologies. Both methods require the applica...
Yaylalı, Yalın Tolga; Fındıkoğlu, Gülin; Yurtdaş, Mustafa; Konukçu, Sibel; Şenol, Hande
2015-09-01
It is unclear which exercise training protocol yields superior heart rate recovery (HRR) improvement in heart failure (HF) patients. Whether baseline HRR normality plays a role in the improvement is unknown. We hypothesized that an exercise training protocol and baseline HRR normality would be factors in altering HRR in HF patients. In this prospective, randomized, controlled and 3 group parallel study, 41 stable HF patients were randomly assigned to 3-times-weekly training sessions for 12 weeks, consisting of i) 30 minutes of interval training (IT) (n=17, 63.7±8.8 years old) versus ii) 30 minutes of continuous training (CT) (n=13, 59.6±6.8 years old) versus iii) no training (CON) (n=11, 60.6±9.9 years old). Each patient had cardiopulmonary exercise testing before and after the training program. Maximum heart rates attained during the test and heart rates at 1 and 2 min (HRR1 and HRR2) during the recovery phase were recorded. Paired samples t-test or Wilcoxon signed-rank test was used for comparisons before and after training. One-way ANOVA or Kruskal-Wallis variance analysis was used for comparisons among groups. HRR1 was unchanged after training. HRR2 improved in the IT group after training, and post-training HRR2 values were significantly faster in the IT group than in controls. Both HRR1 and HRR2 was significantly faster, irrespective of exercise protocol in patients with abnormal baseline values after training. HRR1 did not improve after training. HRR2 improved only in the IT group. Both HRRs in patients with abnormal baseline values improved after both exercise protocols. IT might be superior to CT in improving HRR2. Baseline HRR might play a role in its response to exercise.
Quantum Counterfactual Information Transmission Without a Weak Trace
NASA Astrophysics Data System (ADS)
Arvidsson Shukur, David; Barnes, Crispin
The classical theories of communication rely on the assumption that there has to be a flow of particles from Bob to Alice in order for him to send a message to her. We have developed a quantum protocol that allows Alice to perceive Bob's message ``counterfactually''. That is, without Alice receiving any particles that have interacted with Bob. By utilising a setup built on results from interaction-free measurements and the quantum Zeno effect, we outline a communication protocol in which the information travels in the opposite direction of the emitted particles. In comparison to previous attempts on such protocols, this one is such that a weak measurement at the message source would not leave a weak trace that could be detected by Alice's receiver. Whilst some interaction-free schemes require a large number of carefully aligned beam-splitters, our protocol is realisable with two or more beam-splitters. Furthermore, we outline how Alice's obtained classical Fisher information between a weak variable at Bob's laboratory is negligible in our scheme. We demonstrate this protocol by numerically solving the time-dependent Schrödinger Equation (TDSE) for a Hamiltonian that implements this quantum counterfactual phenomenon.
McCaw, Travis J; Hwang, Min-Sig; Jang, Si Young; Huq, M Saiful
2017-07-01
This work quantified differences between recommendations of the TG-51 and TG-51 addendum reference dosimetry protocols. Reference dosimetry was performed for flattened photon beams with nominal energies of 6, 10, 15, and 23 MV, as well as flattening-filter free (FFF) beam energies of 6 and 10 MV, following the recommendations of both the TG-51 and TG-51 addendum protocols using both a Farmer ® ionization chamber and a scanning ionization chamber with calibration coefficients traceable to absorbed dose-to-water (D w ) standards. Differences in D w determined by the two protocols were 0.1%-0.3% for beam energies with a flattening filter, and up to 0.2% and 0.8% for FFF beams measured with the scanning and Farmer ® ionization chambers, respectively, due to k Q determination, volume-averaging correction, and collimator jaw setting. Combined uncertainty was between 0.91% and 1.2% (k = 1), varying by protocol and detector. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Gkinis, Vasileios; Holme, Christian; Morris, Valerie; Thayer, Abigail Grace; Vaughn, Bruce; Kjaer, Helle Astrid; Vallelonga, Paul; Simonsen, Marius; Jensen, Camilla Marie; Svensson, Anders; Maffrezzoli, Niccolo; Vinther, Bo; Dallmayr, Remi
2017-04-01
We present a performance comparison study between two state of the art Cavity Ring Down Spectrometers (Picarro L2310-i, L2140-i). The comparison took place during the Continuous Flow Analysis (CFA) campaign for the measurement of the Renland ice core, over a period of three months. Instant and complete vaporisation of the ice core melt stream, as well as of in-house water reference materials is achieved by accurate control of microflows of liquid into a homemade calibration system by following simple principles of the Hagen-Poiseuille law. Both instruments share the same vaporisation unit in a configuration that minimises sample preparation discrepancies between the two analyses. We describe our SMOW-SLAP calibration and measurement protocols for such a CFA application and present quality control metrics acquired during the full period of the campaign on a daily basis. The results indicate an unprecedented performance for all 3 isotopic ratios (δ2H, δ17O, δ18O ) in terms of precision, accuracy and resolution. We also comment on the precision and accuracy of the second order excess parameters of HD16O and H217O over H218O (Dxs, Δ17O ). To our knowledge these are the first reported CFA measurements at this level of precision and accuracy for all three isotopic ratios. Differences on the performance of the two instruments are carefully assessed during the measurement and reported here. Our quality control protocols extend to the area of low water mixing ratios, a regime in which often atmospheric vapour measurements take place and Cavity Ring Down Analysers show a poorer performance due to the lower signal to noise ratios. We address such issues and propose calibration protocols from which water vapour isotopic analyses can benefit from.
Faye, Sherry A.; Richards, Jason M.; Gallardo, Athena M.; ...
2017-02-07
Sequential extraction is a useful technique for assessing the potential to leach actinides from soils; however, current literature lacks uniformity in experimental details, making direct comparison of results impossible. This work continued development toward a standardized five-step sequential extraction protocol by analyzing extraction behaviors of 232Th, 238U, 239,240Pu and 241Am from lake and ocean sediment reference materials. Results produced a standardized procedure after creating more defined reaction conditions to improve method repeatability. A NaOH fusion procedure is recommended following sequential leaching for the complete dissolution of insoluble species.
Dunn, Thomas M; Dalton, Alice; Dorfman, Todd; Dunn, William W
2004-01-01
To be a first step in determining whether emergency medicine technician (EMT)-Basics are capable of using a protocol that allows for selective immobilization of the cervical spine. Such protocols are coming into use at an advanced life support level and could be beneficial when used by basic life support providers. A convenience sample of participants (n=95) from 11 emergency medical services agencies and one college class participated in the study. All participants evaluated six patients in written scenarios and decided which should be placed into spinal precautions according to a selective spinal immobilization protocol. Systems without an existing selective spinal immobilization protocol received a one-hour continuing education lecture regarding the topic. College students received a similar lecture written so laypersons could understand the protocol. All participants showed proficiency when applying a selective immobilization protocol to patients in paper-based scenarios. Furthermore, EMT-Basics performed at the same level as paramedics when following the protocol. Statistical analysis revealed no significant differences between EMT-Basics and paramedics. A follow-up group of college students (added to have a non-EMS comparison group) also performed as well as paramedics when making decisions to use spinal precautions. Differences between college students and paramedics were also statistically insignificant. The results suggest that EMT-Basics are as accurate as paramedics when making decisions regarding selective immobilization of the cervical spine during paper-based scenarios. That laypersons are also proficient when using the protocol could indicate that it is extremely simple to follow. This study is a first step toward the necessary additional studies evaluating the efficacy of EMT-Basics using selective immobilization as a regular practice.
Towgood, Karren; Barker, Gareth J; Caceres, Alejandro; Crum, William R; Elwes, Robert D C; Costafreda, Sergi G; Mehta, Mitul A; Morris, Robin G; von Oertzen, Tim J; Richardson, Mark P
2015-04-01
fMRI is increasingly implemented in the clinic to assess memory function. There are multiple approaches to memory fMRI, but limited data on advantages and reliability of different methods. Here, we compared effect size, activation lateralisation, and between-sessions reliability of seven memory fMRI protocols: Hometown Walking (block design), Scene encoding (block design and event-related design), Picture encoding (block and event-related), and Word encoding (block and event-related). All protocols were performed on three occasions in 16 patients with temporal lobe epilepsy (TLE). Group T-maps showed activity bilaterally in medial temporal lobe for all protocols. Using ANOVA, there was an interaction between hemisphere and seizure-onset lateralisation (P = 0.009) and between hemisphere, protocol and seizure-onset lateralisation (P = 0.002), showing that the distribution of memory-related activity between left and right temporal lobes differed between protocols and between patients with left-onset and right-onset seizures. Using voxelwise intraclass Correlation Coefficient, between-sessions reliability was best for Hometown and Scenes (block and event). The between-sessions spatial overlap of activated voxels was also greatest for Hometown and Scenes. Lateralisation of activity between hemispheres was most reliable for Scenes (block and event) and Words (event). Using receiver operating characteristic analysis to explore the ability of each fMRI protocol to classify patients as left-onset or right-onset TLE, only the Words (event) protocol achieved a significantly above-chance classification of patients at all three sessions. We conclude that Words (event) protocol shows the best combination of between-sessions reliability of the distribution of activity between hemispheres and reliable ability to distinguish between left-onset and right-onset patients. © 2015 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.
Comparison of Ovulation Induction Protocols After Endometrioma Resection
Yasa, Cenk; Dural, Ozlem; Mutlu, Mehmet Firat; Celik, Cem; Ugurlucan, Funda Gungor; Buyru, Faruk
2014-01-01
Background and Objectives: The aim of this study was to compare the in vitro fertilization (IVF) outcomes of long gonadotropin-releasing hormone agonist (GnRH-a) and GnRH-antagonist (GnRH-ant) protocols in endometriosis patients who have undergone laparoscopic endometrioma resection surgery. To our knowledge, there is no study in the current literature that compares the effectiveness of long GnRH-a and GnRH-ant protocols in management of IVF cycles in endometriosis patients who underwent laparoscopic endometrioma resection surgery. Methods: Eighty-six patients with stage III to IV endometriosis who had undergone laparoscopic resection surgery for endometrioma were divided into 2 groups: those who had ovarian stimulation with a long GnRH-a protocol (n = 44), and those who had ovarian stimulation with a GnRH-ant protocol (n = 42). Results: The number of follicles on human chorionic gonadotropin injection day, duration of hyperstimulation, number of retrieved metaphase II oocytes, and total number of grade 1 embryos were statically significantly higher in the long GnRH-a protocol. There were no significant differences in positive β-human chorionic gonadotropin pregnancy rates (25% vs 21.4%; P = .269) and ongoing pregnancy rates per patient (20.5% vs 19.1%; P = .302) between the 2 protocols. Conclusions: Long GnRH-a and GnRH-ant protocols both present similar IVF outcomes in patients with endometriosis who have undergone laparoscopic endometrioma resection surgery. A long GnRH-a protocol may lead to a higher number of embryos that can be cryopreserved, providing the possibility of additional embryo transfers without having to go through the process of ovarian stimulation again. PMID:25392665
Şükür, Yavuz Emre; Koyuncu, Kazibe; Seval, Mehmet Murat; Çetinkaya, Esra; Dökmeci, Fulya
2017-12-01
To evaluate the performances of five different βhCG follow-up protocols after single-dose methotrexate therapy for tubal ectopic pregnancy (EP). Data of patients who received single-dose methotrexate therapy for tubal EP at a university hospital between January 2011 and July 2016 were reviewed. A 'successful methotrexate treatment' was defined if the EP treated with no need for surgery. The performances of different protocols were tested by comparing with the currently used '15% βhCG decrease between days 4 and 7' protocol. The tested follow-up protocols were '20, 25%, and any βhCG decrease between days 0/1 and 7' and '20% and any βhCG decrease between days 0/1 and 4'. Among the 96 patients evaluated, 12 (12.5%) required second dose. Totally, 91 (94.8%) patients treated successfully with no need for surgery. Four patients were operated within 4 days following the second dose. One patient who did not need second dose according to the standard follow-up protocol was operated on the 10th day due to rupture (specificity = 80%). Two protocols, namely '20% βhCG decrease between days 0/1 and 7' and 'any βhCG decrease between days 0/1 and 7' did not show statistically significant differences from the index protocol regarding the number of patients who should be assigned to 2nd dose. 'Any βhCG decrease between days 0/1 and 7' protocol may substitute the currently used one to decide second dose methotrexate in tubal EP management. Omitting 4th day measurement seems to be more convenient and cost effective.
2017-08-10
simulation models the conformational plasticity along the helix-forming reaction coordinate was limited by free - energy barriers. By comparison the coarse...revealed. The latter becomes evident in comparing the energy Z-score landscapes , where CHARMM22 simulation shows a manifold of shuttling...solvent simulations of calculating the charging free energy of protein conformations.33 Deviation to the protocol by modification of Born radii
Tan, J S P; Tan, K-L; Lee, J C L; Wan, C-M; Leong, J-L; Chan, L-L
2009-02-01
To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16- and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16- and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols. Three cadaveric heads were scanned on 16- and 64-section MDCT by using standard neuroimaging CT protocols. Eye lens dose was measured by using thermoluminescent dosimeters (TLD), and each scanning was repeated to reduce random error. The dose-length product, volume CT dose index (CTDI(vol)), and TLD readings for each imaging protocol were averaged and compared between scanners and protocols, by using the paired Student t test. Statistical significance was defined at P < .05. The radiation dose delivered and eye lens doses were lower by 28.1%-45.7% (P < .000) on the 64-section MDCT for near-identical imaging protocols. On the 16-section MDCT, lens dose reduction was greatest (81.1%) on a tilted axial mode, compared with a nontilted helical mode for CT brain scans. Among the protocols studied, CT of the temporal bone delivered the greatest radiation dose to the eye lens. Eye lens radiation doses delivered by the 64-section MDCT are significantly lower, partly due to improvements in automatic tube current modulation technology. However, where applicable, protection of the eyes from the radiation beam by either repositioning the head or tilting the gantry remains the best way to reduce eye lens dose.
Weakley, Jonathon Js; Till, Kevin; Read, Dale B; Phibbs, Padraic J; Roe, Gregory; Darrall-Jones, Joshua; Jones, Ben L
2017-08-04
Training that is efficient and effective is of great importance to an athlete. One method of improving efficiency is by incorporating supersets into resistance training routines. However, the structuring of supersets is still unexplored. Therefore, the purpose of this study was to assess the effects of agonist-antagonist (A-A), alternate peripheral (A-P), and similar biomechanical (SB) superset configurations on rate of perceived exertion (RPE), kinetic and kinematic changes during the bench press. 10 subjects performed resistance training protocols in a randomized-crossover design, with magnitude-based inferences assessing changes/differences within and between protocols. Changes in RPE were very likely and almost certainly greater in the A-P and SB protocols when compared with the A-A, while all superset protocols had very likely to almost certain reductions in mean velocity and power from baseline. Reductions in mean velocity and power were almost certainly greater in the SB protocol, with differences between the A-A and A-P protocols being unclear. Decreases in peak force were likely and almost certain in the A-A and SB protocols respectively, with changes in A-P being unclear. Differences between these protocols showed likely greater decreases in SB peak forces when compared to A-A, with all other superset comparisons being unclear. This study demonstrates the importance of exercise selection when incorporating supersets into a training routine. It is suggested that the practitioner uses A-A supersets when aiming to improve training efficiency and minimize reductions in kinetic and kinematic output of the agonist musculature while completing the barbell bench press.
Behbehani, Gregory K.; Thom, Colin; Zunder, Eli R.; Finck, Rachel; Gaudilliere, Brice; Fragiadakis, Gabriela K.; Fantl, Wendy J.; Nolan, Garry P.
2015-01-01
Fluorescent cellular barcoding and mass-tag cellular barcoding are cytometric methods that enable high sample throughput, minimize inter-sample variation, and reduce reagent consumption. Previously employed barcoding protocols require that barcoding be performed after surface marker staining, complicating combining the technique with measurement of alcohol-sensitive surface epitopes. This report describes a method of barcoding fixed cells after a transient partial permeabilization with 0.02% saponin that results in efficient and consistent barcode staining with fluorescent or mass-tagged reagents while preserving surface marker staining. This approach simplifies barcoding protocols and allows direct comparison of surface marker staining of multiple samples without concern for variations in the antibody cocktail volume, antigen-antibody ratio, or machine sensitivity. Using this protocol, cellular barcoding can be used to reliably detect subtle differences in surface marker expression. PMID:25274027
Schmidt, Olga; Hausmann, Axel; Cancian de Araujo, Bruno; Sutrisno, Hari; Peggie, Djunijanti; Schmidt, Stefan
2017-01-01
Here we present a general collecting and preparation protocol for DNA barcoding of Lepidoptera as part of large-scale rapid biodiversity assessment projects, and a comparison with alternative preserving and vouchering methods. About 98% of the sequenced specimens processed using the present collecting and preparation protocol yielded sequences with more than 500 base pairs. The study is based on the first outcomes of the Indonesian Biodiversity Discovery and Information System (IndoBioSys). IndoBioSys is a German-Indonesian research project that is conducted by the Museum für Naturkunde in Berlin and the Zoologische Staatssammlung München, in close cooperation with the Research Center for Biology - Indonesian Institute of Sciences (RCB-LIPI, Bogor).
Is there pre-attentive memory-based comparison of pitch?
Jacobsen, T; Schröger, E
2001-07-01
The brain's responsiveness to changes in sound frequency has been demonstrated by an overwhelming number of studies. Change detection occurs unintentionally and automatically. It is generally assumed that this brain response, the so-called mismatch negativity (MMN) of the event-related brain potential or evoked magnetic field, is based on the outcome of a memory-comparison mechanism rather than being due to a differential state of refractoriness of tonotopically organized cortical neurons. To the authors' knowledge, however, there is no entirely compelling evidence for this belief. An experimental protocol controlling for refractoriness effects was developed and a true memory-comparison-based brain response to pitch change was demonstrated.
Lim, Jiyeon; Park, Eun-Ah; Lee, Whal; Shim, Hackjoon; Chung, Jin Wook
2015-06-01
To assess the image quality and radiation exposure of 320-row area detector computed tomography (320-ADCT) coronary angiography with optimal tube voltage selection with the guidance of an automatic exposure control system in comparison with a body mass index (BMI)-adapted protocol. Twenty-two patients (study group) underwent 320-ADCT coronary angiography using an automatic exposure control system with the target standard deviation value of 33 as the image quality index and the lowest possible tube voltage. For comparison, a sex- and BMI-matched group (control group, n = 22) using a BMI-adapted protocol was established. Images of both groups were reconstructed by an iterative reconstruction algorithm. For objective evaluation of the image quality, image noise, vessel density, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were measured. Two blinded readers then subjectively graded the image quality using a four-point scale (1: nondiagnostic to 4: excellent). Radiation exposure was also measured. Although the study group tended to show higher image noise (14.1 ± 3.6 vs. 9.3 ± 2.2 HU, P = 0.111) and higher vessel density (665.5 ± 161 vs. 498 ± 143 HU, P = 0.430) than the control group, the differences were not significant. There was no significant difference between the two groups for SNR (52.5 ± 19.2 vs. 60.6 ± 21.8, P = 0.729), CNR (57.0 ± 19.8 vs. 67.8 ± 23.3, P = 0.531), or subjective image quality scores (3.47 ± 0.55 vs. 3.59 ± 0.56, P = 0.960). However, radiation exposure was significantly reduced by 42 % in the study group (1.9 ± 0.8 vs. 3.6 ± 0.4 mSv, P = 0.003). Optimal tube voltage selection with the guidance of an automatic exposure control system in 320-ADCT coronary angiography allows substantial radiation reduction without significant impairment of image quality, compared to the results obtained using a BMI-based protocol.
USDA-ARS?s Scientific Manuscript database
Mechanography during the vertical jump test allows for evaluation of force-time variables reflecting jump execution, which may enhance screening for functional deficits that reduce physical performance and determining mechanistic causes underlying performance changes. However, utility of jump mechan...
ASSESSMENT OF LARGE RIVER MACROINVERTEBRATES: HOW FAR IS ENOUGH?
During the summer of 2001, twelve sites were sampled for macroinvertebrates, six each on the Great Miami and Kentucky Rivers. Sites were chosen to reflect a disturbance gradient in each river using sites sampled in a 1999 methods comparison study. Our sampling protocol improves...
DEVELOPMENT OF A PROTOCOL FOR TESTING EFFECTS OF TOXIC SUBSTANCES ON PLANTS
This study was designed to devise a rapid, simple, reproducible bioassay procedure to determine effects of so-called 'toxic substances in the environment' on vegetation and provide a standardized procedure for evaluation and comparison of effects of diverse compounds. Eight diffe...
Microbial Genome Analysis and Comparisons: Web-based Protocols and Resources
USDA-ARS?s Scientific Manuscript database
Fully annotated genome sequences of many microorganisms are publicly available as a resource. However, in-depth analysis of these genomes using specialized tools is required to derive meaningful information. We describe here the utility of three powerful publicly available genome databases and ana...
Typically, in vitro hazard assessments for the identification of endocrine-disrupting compounds (EDCs), including those outlined in the Endocrine Disruptor Screening and Testing Advisory Committee (EDSTAC) Tier 1 Screening protocols, utilize mammalian receptors. Evidence, however...
Preclinical experimental stress studies: protocols, assessment and comparison.
Bali, Anjana; Jaggi, Amteshwar Singh
2015-01-05
Stress is a state of threatened homeostasis during which a variety of adaptive processes are activated to produce physiological and behavioral changes. Preclinical models are pivotal for understanding these physiological or pathophysiological changes in the body in response to stress. Furthermore, these models are also important for the development of novel pharmacological agents for stress management. The well described preclinical stress models include immobilization, restraint, electric foot shock and social isolation stress. Stress assessment in animals is done at the behavioral level using open field, social interaction, hole board test; at the biochemical level by measuring plasma corticosterone and ACTH; at the physiological level by measuring food intake, body weight, adrenal gland weight and gastric ulceration. Furthermore the comparison between different stressors including electric foot shock, immobilization and cold stressor is described in terms of intensity, hormonal release, protein changes in brain, adaptation and sleep pattern. This present review describes these preclinical stress protocols, and stress assessment at different levels. Copyright © 2014 Elsevier B.V. All rights reserved.
[Prolonged desensitization pretreatment for in vitro fertilization in women with polycystic ovary].
Kuczyński, W; Czech, R; Redźko, S; Wasilewski, T; Mrugacz, G; Wołczyński, S; Pietrewicz, P; Grochowski, D; Szamatowicz, M
2000-09-01
To analyse the outcome of intracytoplasmic sperm injection (ICSI) in women with severe polycystic ovary disease (PCD), stimulated after prolonged pituitary desensitization in comparison with regular long protocol therapy. The results of controlled ovarian hyperstimulation (COH), fertilization rate, early embryo development parameters and clinical pregnancy rates were compared depending on the duration of pituitary desensitization before gonadotropin administration. A total of 60 patients with severe PCOD were desensitized with GnRH agonist up to 30 days before COH. The results were compared with the group of 213 patients with mild PCOD treated with regular long protocol (control). We observed a slightly higher rate of mature oocytes MII as well as the number of embryos obtained in the control group, however the pregnancy rate in the group with prolonged desensitization was significantly higher (50%) in comparison to the control group (33.8%). The prolonged pituitary desensitization before controlled ovarian hyperstimulation gives better chance for obtaining pregnancy in patients with severe PCOD. It could be recommended facing previous treatment failure.
Lando, David; Stevens, Tim J; Basu, Srinjan; Laue, Ernest D
2018-01-01
Single-cell chromosome conformation capture approaches are revealing the extent of cell-to-cell variability in the organization and packaging of genomes. These single-cell methods, unlike their multi-cell counterparts, allow straightforward computation of realistic chromosome conformations that may be compared and combined with other, independent, techniques to study 3D structure. Here we discuss how single-cell Hi-C and subsequent 3D genome structure determination allows comparison with data from microscopy. We then carry out a systematic evaluation of recently published single-cell Hi-C datasets to establish a computational approach for the evaluation of single-cell Hi-C protocols. We show that the calculation of genome structures provides a useful tool for assessing the quality of single-cell Hi-C data because it requires a self-consistent network of interactions, relating to the underlying 3D conformation, with few errors, as well as sufficient longer-range cis- and trans-chromosomal contacts.
Boar taint detection: A comparison of three sensory protocols.
Trautmann, Johanna; Meier-Dinkel, Lisa; Gertheiss, Jan; Mörlein, Daniel
2016-01-01
While recent studies state an important role of human sensory methods for daily routine control of so-called boar taint, the evaluation of different heating methods is still incomplete. This study investigated three common heating methods (microwave (MW), hot-water (HW), hot-iron (HI)) for boar fat evaluation. The comparison was carried out on 72 samples with a 10-person sensory panel. The heating method significantly affected the probability of a deviant rating. Compared to an assumed 'gold standard' (chemical analysis), the performance was best for HI when both sensitivity and specificity were considered. The results show the superiority of the panel result compared to individual assessors. However, the consistency of the individual sensory ratings was not significantly different between MW, HW, and HI. The three protocols showed only fair to moderate agreement. Concluding from the present results, the hot-iron method appears to be advantageous for boar taint evaluation as compared to microwave and hot-water. Copyright © 2015. Published by Elsevier Ltd.
Lautscham, E M; Kessler, M; Ernst, T; Willimzig, L; Neiger, R
2017-03-25
The recommendation to treat canine lymphoma with a discontinuous protocol is based on small case numbers and mostly historic controls. This study compares duration of first remission (DFR) and overall survival time (ST) with a discontinuous protocol to the same protocol with maintenance phase. 408 dogs were treated with a CHOP-LAsp (C=cyclophosphamide; H=hydroxydaunorubicin; O=Oncovin; P=prednisolone; LAsp=l-asparaginase)-based 28-week induction protocol. In 75 dogs (cohort 1), this was followed by a maintenance phase consisting of vincristine, chlorambucil and actinomycin-D with a total treatment duration of two years. In the subsequent 333 dogs, therapy was discontinued after induction (cohort 2). Median DFR and ST in cohort 1 were 216 and 375 days and 184 and 304 days in cohort 2. 6-Month, 1-year and 2-year survival rates in cohort 1 were 73 per cent, 50 per cent, 24 per cent and 67 per cent, 39 per cent, 21 per cent in cohort 2. There was no significant difference between the two protocols (P=0.291 for ST, P=0.071 for DFR). On multivariate analysis, corticosteroid pretreatment (P=0.005), thrombocytopenia at diagnosis (P=0.019), stage (P=0.009), substage b at relapse (P<0.001), age (P=0.002) and incomplete or unstable remission necessitating intensification of therapy (P=0.004) were negatively correlated with ST in both groups. This study supports the use of a discontinuous protocol for canine multicentric lymphoma. British Veterinary Association.
Alba, Annia; Marcet, Ricardo; Otero, Oscar; Hernández, Hilda M; Figueredo, Mabel; Sarracent, Jorge
2016-02-01
Purification of immunoglobulin M (IgM) antibodies could be challenging, and is often characterized by the optimization of the purification protocol to best suit the particular features of the molecule. Here, two different schemes were compared to purify, from ascites, the 1E4 IgM monoclonal antibody (mAb) previously raised against the stage of redia of the trematode Fasciola hepatica. This immunoglobulin is used as capture antibody in an immunoenzymatic assay to detect parasite ongoing infection in its intermediate hosts. The first purification protocol of the 1E4 mAb involved two chromatographic steps: an affinity chromatography on a Concanavalin A matrix followed by size exclusion chromatography. An immunoaffinity chromatography was selected as the second protocol for one-step purification of the antibody using the crude extract of adult parasites coupled to a commercial matrix. Immunoreactivity of the fractions during purification schemes was assessed by indirect immunoenzymatic assays against the crude extract of F. hepatica rediae, while purity was estimated by protein electrophoresis. Losses on the recovery of the antibody isolated by the first purification protocol occurred due to protein precipitation during the concentration of the sample and to low resolution of the size exclusion molecular chromatography step regarding this particular immunoglobulin. The immunoaffinity chromatography using F. hepatica antigens as ligands proved to be the most suitable protocol yielding a pure and immunoreactive antibody. The purification protocols used are discussed regarding efficiency and difficulties.
A review of seafood safety after the deepwater horizon blowout.
Gohlke, Julia M; Doke, Dzigbodi; Tipre, Meghan; Leader, Mark; Fitzgerald, Timothy
2011-08-01
The Deepwater Horizon (DH) blowout resulted in fisheries closings across the Gulf of Mexico. Federal agencies, in collaboration with impacted Gulf states, developed a protocol to determine when it is safe to reopen fisheries based on sensory and chemical analyses of seafood. All federal waters have been reopened, yet concerns have been raised regarding the robustness of the protocol to identify all potential harmful exposures and protect the most sensitive populations. We aimed to assess this protocol based on comparisons with previous oil spills, published testing results, and current knowledge regarding chemicals released during the DH oil spill. We performed a comprehensive review of relevant scientific journal articles and government documents concerning seafood contamination and oil spills and consulted with academic and government experts. Protocols to evaluate seafood safety before reopening fisheries have relied on risk assessment of health impacts from polycyclic aromatic hydrocarbon (PAH) exposures, but metal contamination may also be a concern. Assumptions used to determine levels of concern (LOCs) after oil spills have not been consistent across risk assessments performed after oil spills. Chemical testing results after the DH oil spill suggest PAH levels are at or below levels reported after previous oil spills, and well below LOCs, even when more conservative parameters are used to estimate risk. We recommend use of a range of plausible risk parameters to set bounds around LOCs, comparisons of post-spill measurements with baseline levels, and the development and implementation of long-term monitoring strategies for metals as well as PAHs and dispersant components. In addition, the methods, results, and uncertainties associated with estimating seafood safety after oil spills should be communicated in a transparent and timely manner, and stakeholders should be actively involved in developing a long-term monitoring strategy.
Richtrova, Pavlina; Opatrny, Karel; Vit, Ladislav; Sefrna, Frantisek; Perlik, Radek
2007-10-01
Thrombogenicity is an important parameter of haemodialysis (HD) membrane biocompatibility. The surface of the polyacrylonitrile AN69 ST membrane is coated with a polyethylenimine. This modification allows heparin adsorption. The binding of heparin to the membrane surface occurs during priming of the extracorporeal circuit (ECC) by rinsing it with saline and heparin. Our aims were to assess and compare the thrombogenicity of the AN69 ST membrane under conditions of two extracorporeal circuit (ECC) rinse protocols-with and without unfractionated heparin (UFH). In a prospective, crossover and randomized study, we examined 10 patients during HD after ECC preparation with either rinse protocols. Prior to HD and at 15, 60 and 240 min, we determined plasma levels of the thrombin-antithrombin complexes (TAT), platelet factor 4 (PF4), heparin concentration (antiXa) and thrombocyte count. Systemic anticoagulation was performed using UFH. During HD after ECC rinse without UFH, there was a significantly earlier and more marked increase in TAT compared with UFH-containing rinse (P <0.05). Using Spearman coefficient, we demonstrated a significant correlation between TAT and antiXa at 60 min (r = -0.534) and 240 min (r = -0.538). A comparison of the TAT/antiXa ratios between rinses at 60 min revealed a significantly higher increase in TAT following UFH-free rinse (P <0.05). There was no difference in PF4 between the rinses. Platelet count did not change significantly during HD using either rinse protocol. Based on plasma TAT levels, ECC priming with an UFH-containing solution reduces the thrombogenicity of the AN69 ST membrane. There is no significant difference between both types of priming concerning PF4 and thrombocyte count.
Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan
2008-04-01
Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.
DCBRP: a deterministic chain-based routing protocol for wireless sensor networks.
Marhoon, Haydar Abdulameer; Mahmuddin, M; Nor, Shahrudin Awang
2016-01-01
Wireless sensor networks (WSNs) are a promising area for both researchers and industry because of their various applications The sensor node expends the majority of its energy on communication with other nodes. Therefore, the routing protocol plays an important role in delivering network data while minimizing energy consumption as much as possible. The chain-based routing approach is superior to other approaches. However, chain-based routing protocols still expend substantial energy in the Chain Head (CH) node. In addition, these protocols also have the bottleneck issues. A novel routing protocol which is Deterministic Chain-Based Routing Protocol (DCBRP). DCBRP consists of three mechanisms: Backbone Construction Mechanism, Chain Head Selection (CHS), and the Next Hop Connection Mechanism. The CHS mechanism is presented in detail, and it is evaluated through comparison with the CCM and TSCP using an ns-3 simulator. It show that DCBRP outperforms both CCM and TSCP in terms of end-to-end delay by 19.3 and 65%, respectively, CH energy consumption by 18.3 and 23.0%, respectively, overall energy consumption by 23.7 and 31.4%, respectively, network lifetime by 22 and 38%, respectively, and the energy*delay metric by 44.85 and 77.54%, respectively. DCBRP can be used in any deterministic node deployment applications, such as smart cities or smart agriculture, to reduce energy depletion and prolong the lifetimes of WSNs.
Olson, Nancy C
2016-06-01
To compare 2 standard protocols for head elevation following removal of a femoral artery sheath after coronary angiography and their effects on bleeding complications and reported levels of back pain. One protocol involved flat supine bed rest; the other allowed progressive head elevation. A prospective comparative study of 80 adult patients undergoing coronary angiography via the femoral approach. The Numeric Rating Scale was used as the measure of reported pain. No bleeding complications occurred in either group. Both groups had very low mean pain scores. Repeated-measures analysis demonstrated that the experience of pain differed significantly over time by location (F5,70 = 3.864, P = .004), with a notable decrease in pain scores more than 1 hour after sheath removal at the location that used the progressive head elevation protocol. Patients' satisfaction scores after discharge did not differ significantly between the 2 groups. Patients with a history of chronic back pain had consistently higher pain scores, but those pain scores did not differ significantly by location (or protocol). It appears that using a progressive head-elevation protocol within the first 3 hours after diagnostic angiography is not associated with an increased risk of bleeding complications at the access site and warrants further exploration in the mitigation of back pain associated with prolonged supine bed rest. ©2016 American Association of Critical-Care Nurses.
Afshari, Amirali; Uhde-Stone, Claudia; Lu, Biao
2015-03-13
Luciferase assay has become an increasingly important technique to monitor a wide range of biological processes. However, the mainstay protocols require a luminometer to acquire and process the data, therefore limiting its application to specialized research labs. To overcome this limitation, we have developed an alternative protocol that utilizes a commonly available cooled charge-coupled device (CCCD), instead of a luminometer for data acquiring and processing. By measuring activities of different luciferases, we characterized their substrate specificity, assay linearity, signal-to-noise levels, and fold-changes via CCCD. Next, we defined the assay parameters that are critical for appropriate use of CCCD for different luciferases. To demonstrate the usefulness in cultured mammalian cells, we conducted a case study to examine NFκB gene activation in response to inflammatory signals in human embryonic kidney cells (HEK293 cells). We found that data collected by CCCD camera was equivalent to those acquired by luminometer, thus validating the assay protocol. In comparison, The CCCD-based protocol is readily amenable to live-cell and high-throughput applications, offering fast simultaneous data acquisition and visual and quantitative data presentation. In conclusion, the CCCD-based protocol provides a useful alternative for monitoring luciferase reporters. The wide availability of CCCD will enable more researchers to use luciferases to monitor and quantify biological processes. Copyright © 2015 Elsevier Inc. All rights reserved.
NGS Pretesting and QC Using Illumina Infinium Arrays CIDR IGES Posters - 2017 A Comparison of Methods fragmentation methods for input into library construction protocol Development of a Low Input FFPE workflow for Evaluation of Copy Number Variation (CNV) detection methods in whole exome sequencing (WES) data CIDR AGBT
THE INFLUENCE OF PHYSICAL FACTORS ON COMPARATIVE PERFORMANCE OF SAMPLING METHODS IN LARGE RIVERS
In 1999, we compared five existing benthic macroinvertebrate sampling methods used in boatable rivers. Each sampling protocol was performed at each of 60 sites distributed among four rivers in the Ohio River drainage basin. Initial comparison of methods using key macroinvertebr...
Randomized Comparison of 3 Methods to Screen for Domestic Violence in Family Practice
Chen, Ping-Hsin; Rovi, Sue; Washington, Judy; Jacobs, Abbie; Vega, Marielos; Pan, Ko-Yu; Johnson, Mark S.
2007-01-01
PURPOSE We undertook a study to compare 3 ways of administering brief domestic violence screening questionnaires: self-administered questionnaire, medical staff interview, and physician interview. METHODS We conducted a randomized trial of 3 screening protocols for domestic violence in 4 urban family medicine practices with mostly minority patients. We randomly assigned 523 female patients, aged 18 years or older and currently involved with a partner, to 1 of 3 screening protocols. Each included 2 brief screening tools: HITS and WAST-Short. Outcome measures were domestic violence disclosure, patient and clinician comfort with the screening, and time spent screening. RESULTS Overall prevalence of domestic violence was 14%. Most patients (93.4%) and clinicians (84.5%) were comfortable with the screening questions and method of administering them. Average time spent screening was 4.4 minutes. Disclosure rates, patient and clinician comfort with screening, and time spent screening were similar among the 3 protocols. In addition, WAST-Short was validated in this sample of minority women by comparison with HITS and with the 8-item WAST. CONCLUSIONS Domestic violence is common, and we found that most patients and clinicians are comfortable with domestic violence screening in urban family medicine settings. Patient self-administered domestic violence screening is as effective as clinician interview in terms of disclosure, comfort, and time spent screening. PMID:17893385
A Protocol for Lifetime Energy and Environmental Impact Assessment of Building Insulation Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Biswas, Kaushik; Desjarlais, Andre Omer
This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors, and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules existmore » that provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines.« less
Lie, Marie Udnesseter; Matre, Dagfinn; Hansson, Per; Stubhaug, Audun; Zwart, John-Anker; Nilsen, Kristian Bernhard
2017-01-01
Abstract Introduction: The interest in conditioned pain modulation (CPM) as a clinical tool for measuring endogenously induced analgesia is increasing. There is, however, large variation in the CPM methodology, hindering comparison of results across studies. Research comparing different CPM protocols is needed in order to obtain a standardized test paradigm. Objectives: The aim of the study was to assess whether a protocol with phasic heat stimuli as test-stimulus is preferable to a protocol with tonic heat stimulus as test-stimulus. Methods: In this experimental crossover study, we compared 2 CPM protocols with different test-stimulus; one with tonic test-stimulus (constant heat stimulus of 120-second duration) and one with phasic test-stimuli (3 heat stimulations of 5 seconds duration separated by 10 seconds). Conditioning stimulus was a 7°C water bath in parallel with the test-stimulus. Twenty-four healthy volunteers were assessed on 2 occasions with minimum 1 week apart. Differences in the magnitude and test–retest reliability of the CPM effect in the 2 protocols were investigated with repeated-measures analysis of variance and by relative and absolute reliability indices. Results: The protocol with tonic test-stimulus induced a significantly larger CPM effect compared to the protocol with phasic test-stimuli (P < 0.001). Fair and good relative reliability was found with the phasic and tonic test-stimuli, respectively. Absolute reliability indices showed large intraindividual variability from session to session in both protocols. Conclusion: The present study shows that a CPM protocol with a tonic test-stimulus is preferable to a protocol with phasic test-stimuli. However, we emphasize that one should be cautious to use the CPM effect as biomarker or in clinical decision making on an individual level due to large intraindividual variability. PMID:29392240
NASA Astrophysics Data System (ADS)
Martinez, Ralph; Nam, Jiseung
1992-07-01
Picture Archiving and Communication Systems (PACS) is an integration of digital image formation in a hospital, which encompasses various imaging equipment, image viewing workstations, image databases, and a high speed network. The integration requires a standardization of communication protocols to connect devices from different vendors. The American College of Radiology and the National Electrical Manufacturers Association (ACR- NEMA) standard Version 2.0 provides a point-to-point hardware interface, a set of software commands, and a consistent set of data formats for PACS. But, it is inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks and an approach were proposed to ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS''s capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization/Open Systems Interconnection (ISO/OSI), TCP/IP protocols, and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the ISO-based protocol into a PACS prototype. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance comparison between the ISO and TCP/IP implementations are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is done by prototyping PACS on available platforms, which are Micro VAX II, DECstation and SUN Workstation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Jundi, I.M.
Qatar NGL/2 plant, commissioned in December, 1979, was designed to process the associated gas from the offshore crude oil fields of Qatar. The dehydrated sour lean gas and wet sour liquids are transported via two separate lines to Umm Said NGL Complex about 120 kms. from the central offshore station. The liquids line 300 mm diameter (12 inch) has suffered general and severe pitting corrosion. The lean gas line 600 mm diameter (24 inch) has suffered corrosion and extensively hydrogen induced cracking (HIC), also known as HIPC. Both lines never performed to their design parameters and many problems in themore » downstream facilities have been experienced. All efforts to clean the liquids lines from the solids (debris) have failed. This inturn interfered with the planned corrosion control programe, thus allowing corrosion to continue. Investigation work has been done by various specialists in an attempt to find the origin of the solids and to recommend necessary remedial actions. Should lines fall from pitting corrosion, the effect of liquids leak at a pressure of about 11000 kpa will be very dangerous especially if it occurs onshore. In order to protect the NGL-2 operations against possible risks, both interms of safety as well as losses in revenue, critically sections of the pipelines have been replaced, whilst the whole gas liquids pipelines would be replaced shortly. Supplementary documents to the API standards were prepared by QPC for the replaced pipelines.« less
NASA Astrophysics Data System (ADS)
Yang, D.-M.; Stronach, A. F.; MacConnell, P.; Penman, J.
2002-03-01
This paper addresses the development of a novel condition monitoring procedure for rolling element bearings which involves a combination of signal processing, signal analysis and artificial intelligence methods. Seven approaches based on power spectrum, bispectral and bicoherence vibration analyses are investigated as signal pre-processing techniques for application in the diagnosis of a number of induction motor rolling element bearing conditions. The bearing conditions considered are a normal bearing and bearings with cage and inner and outer race faults. The vibration analysis methods investigated are based on the power spectrum, the bispectrum, the bicoherence, the bispectrum diagonal slice, the bicoherence diagonal slice, the summed bispectrum and the summed bicoherence. Selected features are extracted from the vibration signatures so obtained and these are used as inputs to an artificial neural network trained to identify the bearing conditions. Quadratic phase coupling (QPC), examined using the magnitude of bispectrum and bicoherence and biphase, is shown to be absent from the bearing system and it is therefore concluded that the structure of the bearing vibration signatures results from inter-modulation effects. In order to test the proposed procedure, experimental data from a bearing test rig are used to develop an example diagnostic system. Results show that the bearing conditions examined can be diagnosed with a high success rate, particularly when using the summed bispectrum signatures.
A comparison of methods to assess long-term changes in Sonoran Desert vegetation
Munson, S.M.; Webb, R.H.; Hubbard, J.A.
2011-01-01
Knowledge about the condition of vegetation cover and composition is critical for assessing the structure and function of ecosystems. To effectively quantify the impacts of a rapidly changing environment, methods to track long-term trends of vegetation must be precise, repeatable, and time- and cost-efficient. Measuring vegetation cover and composition in arid and semiarid regions is especially challenging because vegetation is typically sparse, discontinuous, and individual plants are widely spaced. To meet the goal of long-term vegetation monitoring in the Sonoran Desert and other arid and semiarid regions, we determined how estimates of plant species, total vegetation, and soil cover obtained using a widely-implemented monitoring protocol compared to a more time- and resource-intensive plant census. We also assessed how well this protocol tracked changes in cover through 82 years compared to the plant census. Results from the monitoring protocol were comparable to those from the plant census, despite low and variable plant species cover. Importantly, this monitoring protocol could be used as a rapid, "off-the shelf" tool for assessing land degradation (or desertification) in arid and semiarid ecosystems.
A Survey of Authentication Schemes in Telecare Medicine Information Systems.
Aslam, Muhammad Umair; Derhab, Abdelouahid; Saleem, Kashif; Abbas, Haider; Orgun, Mehmet; Iqbal, Waseem; Aslam, Baber
2017-01-01
E-Healthcare is an emerging field that provides mobility to its users. The protected health information of the users are stored at a remote server (Telecare Medical Information System) and can be accessed by the users at anytime. Many authentication protocols have been proposed to ensure the secure authenticated access to the Telecare Medical Information System. These protocols are designed to provide certain properties such as: anonymity, untraceability, unlinkability, privacy, confidentiality, availability and integrity. They also aim to build a key exchange mechanism, which provides security against some attacks such as: identity theft, password guessing, denial of service, impersonation and insider attacks. This paper reviews these proposed authentication protocols and discusses their strengths and weaknesses in terms of ensured security and privacy properties, and computation cost. The schemes are divided in three broad categories of one-factor, two-factor and three-factor authentication schemes. Inter-category and intra-category comparison has been performed for these schemes and based on the derived results we propose future directions and recommendations that can be very helpful to the researchers who work on the design and implementation of authentication protocols.
Meyer, C W; Solano, A
2016-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.
Meyer, C.W.; Solano, A.
2016-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029
Worldwide trends in volume and quality of published protocols of randomized controlled trials
Alldinger, Ingo; Cieslak, Kasia P.; Wennink, Roos; Clarke, Mike; Ali, Usama Ahmed; Besselink, Marc G. H.
2017-01-01
Introduction Publishing protocols of randomized controlled trials (RCT) facilitates a more detailed description of study rational, design, and related ethical and safety issues, which should promote transparency. Little is known about how the practice of publishing protocols developed over time. Therefore, this study describes the worldwide trends in volume and methodological quality of published RCT protocols. Methods A systematic search was performed in PubMed and EMBASE, identifying RCT protocols published over a decade from 1 September 2001. Data were extracted on quality characteristics of RCT protocols. The primary outcome, methodological quality, was assessed by individual methodological characteristics (adequate generation of allocation, concealment of allocation and intention-to-treat analysis). A comparison was made by publication period (First, September 2001- December 2004; Second, January 2005-May 2008; Third, June 2008-September 2011), geographical region and medical specialty. Results The number of published RCT protocols increased from 69 in the first, to 390 in the third period (p<0.0001). Internal medicine and paediatrics were the most common specialty topics. Whereas most published RCT protocols in the first period originated from North America (n = 30, 44%), in the second and third period this was Europe (respectively, n = 65, 47% and n = 190, 48%, p = 0.02). Quality of RCT protocols was higher in Europe and Australasia, compared to North America (OR = 0.63, CI = 0.40–0.99, p = 0.04). Adequate generation of allocation improved with time (44%, 58%, 67%, p = 0.001), as did concealment of allocation (38%, 53%, 55%, p = 0.03). Surgical protocols had the highest quality among the three specialty topics used in this study (OR = 1.94, CI = 1.09–3.45, p = 0.02). Conclusion Publishing RCT protocols has become popular, with a five-fold increase in the past decade. The quality of published RCT protocols also improved, although variation between geographical regions and across medical specialties was seen. This emphasizes the importance of international standards of comprehensive training in RCT methodology. PMID:28296925
Cvetanovich, Gregory L; Lizzio, Vincent; Meta, Fabien; Chan, Derek; Zaltz, Ira; Nho, Shane J; Makhni, Eric C
2017-11-01
To assess comprehensiveness and variability of postoperative physical therapy protocols published online following hip arthroscopy for femoroacetabular impingement (FAI) and/or labral repair. Surgeons were identified by the International Society for Hip Arthroscopy "Find a Surgeon" feature in North America (http://www.isha.net/members/, search August 10, 2016). Exclusion criteria included nonsurgeons and protocols for conditions other than hip arthroscopy for FAI and/or labral tear. Protocols were identified by review of surgeons' personal and departmental websites and evaluated for postoperative restrictions, rehabilitation components, and the time points for ending restrictions and initiating activities. Of 111 surgeons available online, 31 (27.9%) had postoperative hip arthroscopy physical therapy protocols available online. Bracing was used in 54.8% (17/31) of protocols for median 2-week duration (range, 1-6 weeks). Most protocols specified the initial postoperative weight-bearing status (29/31, 93.5%), most frequently partial weight-bearing with 20 pounds foot flat (20/29, 69.0%). The duration of weight-bearing restriction was median 3 weeks (range, 2-6) for FAI and median 6 weeks (range, 3-8) for microfracture. The majority of protocols specified initial range of motion limitations (26/31, 83.9%) for median 3 weeks (range, 1.5-12). There was substantial variation in the rehabilitation activities and time points for initiating activities. Time to return to running was specified by 20/31 (64.5%) protocols at median 12 weeks (range, 6-19), and return to sport timing was specified by 13/31 (41.9%) protocols at median 15.5 weeks (range, 9-23). There is considerable variability in postoperative physical therapy protocols available online following hip arthroscopy for FAI, including postoperative restrictions, rehabilitation activities, and time points for activities. This information offers residents, fellows, and established hip arthroscopists a centralized comparison of publicly available physical therapy protocols following hip arthroscopy. Practicing arthroscopists might find this analysis useful to compare various therapy strategies to their own recommendations. The variability we report can also provide inspiration for future efficacy research toward a more standard rehabilitation. Copyright © 2017. Published by Elsevier Inc.
Comparison of two MAC protocols based on LEO satellite networks
NASA Astrophysics Data System (ADS)
Guan, Mingxiang; Wang, Ruichun
2009-12-01
With the development of LEO satellite communication, it is the basic requirement that various kinds of services will be provided. Considering that weak channel collision detection ability, long propagation delay and heavy load in LEO satellite communication system, a valid adaptive access control protocol APRMA is proposed. Different access probability functions for different services are obtained and appropriate access probabilities for voice and data users are updated slot by slot based on the estimation of the voice traffic and the channel status. Finally simulation results demonstrate that the performance of system is improved by the APRMA compared with the conventional PRMA, with an acceptable trade-off between QoS of voice and delay of data. Also the APRMA protocol will be suitable for HAPS (high altitude platform station) with the characters of weak channel collision detection ability, long propagation delay and heavy load.
An improved 96-well turbidity assay for T4 lysozyme activity.
Toro, Tasha B; Nguyen, Thao P; Watt, Terry J
2015-01-01
T4 lysozyme (T4L) is an important model system for investigating the relationship between protein structure and function. Despite being extensively studied, a reliable, quantitative activity assay for T4L has not been developed. Here, we present an improved T4L turbidity assay as well as an affinity-based T4L expression and purification protocol. This assay is designed for 96-well format and utilizes conditions amenable for both T4L and other lysozymes. This protocol enables easy, efficient, and quantitative characterization of T4L variants and allows comparison between different lysozymes. Our method: •Is applicable for all lysozymes, with enhanced sensitivity for T4 lysozyme compared to other 96-well plate turbidity assays;•Utilizes standardized conditions for comparing T4 lysozyme variants and other lysozymes; and•Incorporates a simplified expression and purification protocol for T4 lysozyme.
An improved 96-well turbidity assay for T4 lysozyme activity
Toro, Tasha B.; Nguyen, Thao P.; Watt, Terry J.
2015-01-01
T4 lysozyme (T4L) is an important model system for investigating the relationship between protein structure and function. Despite being extensively studied, a reliable, quantitative activity assay for T4L has not been developed. Here, we present an improved T4L turbidity assay as well as an affinity-based T4L expression and purification protocol. This assay is designed for 96-well format and utilizes conditions amenable for both T4L and other lysozymes. This protocol enables easy, efficient, and quantitative characterization of T4L variants and allows comparison between different lysozymes. Our method: • Is applicable for all lysozymes, with enhanced sensitivity for T4 lysozyme compared to other 96-well plate turbidity assays; • Utilizes standardized conditions for comparing T4 lysozyme variants and other lysozymes; and • Incorporates a simplified expression and purification protocol for T4 lysozyme. PMID:26150996
Hausmann, Axel; Cancian de Araujo, Bruno; Sutrisno, Hari; Peggie, Djunijanti; Schmidt, Stefan
2017-01-01
Abstract Here we present a general collecting and preparation protocol for DNA barcoding of Lepidoptera as part of large-scale rapid biodiversity assessment projects, and a comparison with alternative preserving and vouchering methods. About 98% of the sequenced specimens processed using the present collecting and preparation protocol yielded sequences with more than 500 base pairs. The study is based on the first outcomes of the Indonesian Biodiversity Discovery and Information System (IndoBioSys). IndoBioSys is a German-Indonesian research project that is conducted by the Museum für Naturkunde in Berlin and the Zoologische Staatssammlung München, in close cooperation with the Research Center for Biology – Indonesian Institute of Sciences (RCB-LIPI, Bogor). PMID:29134041
Atencia, Rebeca; Stöhr, Eric J; Drane, Aimee L; Stembridge, Mike; Howatson, Glyn; Del Rio, Pablo Rodriguez Lopez; Feltrer, Yedra; Tafon, Babila; Redrobe, Sharon; Peck, Bruce; Eng, Jaclyn; Unwin, Steve; Sanchez, Carlos R; Shave, Rob E
2017-09-01
Limited data are available on hemodynamic responses to anesthetic protocols in wild-born chimpanzees (Pan troglodytes). Accordingly, this study characterized the heart rate (HR) and blood pressure responses to four anesthetic protocols in 176 clinically healthy, wild-born chimpanzees undergoing routine health assessments. Animals were anesthetized with medetomidine-ketamine (MK) (n = 101), tiletamine-zolazepam (TZ) (n = 30), tiletamine-zolazepam-medetomidine (TZM) (n = 24), or medetomidine-ketamine (maintained with isoflurane) (MKI) (n = 21). During each procedure, HR, systolic blood pressure (SBP), and diastolic blood pressure (DBP) were regularly recorded. Data were grouped according to anesthetic protocol, and mean HR, SBP, and DBP were calculated. Differences between mean HR, SBP, and DBP for each anesthetic protocol were assessed using the Kruskall-Wallis test and a Dunn multiple comparisons post hoc analysis. To assess the hemodynamic time course response to each anesthetic protocol, group mean data (±95% confidence interval [CI]) were plotted against time postanesthetic induction. Mean HR (beats/min [CI]) was significantly higher in TZ (86 [80-92]) compared to MKI (69 [61-78]) and MK (62 [60-64]) and in TZM (73 [68-78]) compared to MK. The average SBP and DBP values (mm Hg [CI]) were significantly higher in MK (130 [126-134] and 94 [91-97]) compared to TZ (104 [96-112] and 58 [53-93]) and MKI (113 [103-123] and 78 [69-87]) and in TZM (128 [120-135] and 88 [83-93]) compared to TZ. Time course data were markedly different between protocols, with MKI showing the greatest decline over time. Both the anesthetic protocol adopted and the timing of measurement after injection influence hemodynamic recordings in wild-born chimpanzees and need to be considered when monitoring or assessing cardiovascular health.
Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T.
Prakkamakul, Supada; Witzel, Thomas; Huang, Susie; Boulter, Daniel; Borja, Maria J; Schaefer, Pamela; Rosen, Bruce; Heberlein, Keith; Ratai, Eva; Gonzalez, Gilberto; Rapalino, Otto
2016-09-01
To compare an ultrafast brain magnetic resonance imaging (MRI) protocol to the conventional protocol in motion-prone inpatient clinical settings. This retrospective study was HIPAA compliant and approved by the Institutional Review Board with waived inform consent. Fifty-nine inpatients (30 males, 29 females; mean age 55.1, range 23-93 years)who underwent 3-Tesla brain MRI using ultrafast and conventional protocols, both including five sequences, were included in the study. The total scan time for five ultrafast sequences was 4 minutes 59 seconds. The ideal conventional acquisition time was 10 minutes 32 seconds but the actual acquisition took 15-20 minutes. The average scan times for ultrafast localizers, T1-weighted, T2-weighted, fluid-attenuated inversion recovery (FLAIR), diffusion-weighted, T2*-weighted sequences were 14, 41, 62, 96, 80, 6 seconds, respectively. Two blinded neuroradiologists independently assessed three aspects: (1) image quality, (2) gray-white matter (GM-WM) differentiation, and (3) diagnostic concordance for the detection of six clinically relevant imaging findings. Wilcoxon signed-rank test was used to compare image quality and GM-WM scores. Interobserver reproducibility was calculated. The ultrafast T1-weighted sequence demonstrated significantly better image quality (P = .005) and GM-WM differentiation (P < .001) compared to the conventional sequence. There was high agreement (>85%) between both protocols for the detection of mass-like lesion, hemorrhage, diffusion restriction, WM FLAIR hyperintensities, subarachnoid FLAIR hyperintensities, and hydrocephalus. The ultrafast protocol achieved at least comparable image quality and high diagnostic concordance compared to the conventional protocol. This fast protocol can be a viable option to replace the conventional protocol in motion-prone inpatient clinical settings. Copyright © 2016 by the American Society of Neuroimaging.
Comparison of two instruments for assessing risk of postoperative nausea and vomiting.
Kapoor, Rachna; Hola, Eric T; Adamson, Robert T; Mathis, A Scott
2008-03-01
Two instruments for assessing patients' risk of postoperative nausea and vomiting (PONV) were compared. The existing protocol (protocol 1) assessed PONV risk using 16 weighted risk factors and was used for both adults and pediatric patients. The new protocol (protocol 2) included a form for adults and a pediatric-specific form. The form for adults utilized the simplified risk score, calculated using a validated, nonweighted, 4-point scale, and categorized patients' risk of PONV as low, moderate, or high. The form for pediatric patients used a 7-point, non-weighted scale and categorized patients' risk of PONV as moderate or high. A list was generated of all patients who had surgery during August 2005, for whom protocol 1 was used, and during April 2006, for whom protocol 2 was used. Fifty patients from each time period were randomly selected for data analysis. Data collected included the percentage of the form completed, the development of PONV, the number of PONV risk factors, patient demographics, and the appropriateness of prophylaxis. The mean +/- S.D. number of PONV risk factors was significantly lower in the group treated according to protocol 2 ( p = 0.001), but fewer patients in this group were categorized as low or moderate risk and more patients were identified as high risk (p < 0.001). More patients assessed by protocol 2 received fewer interventions than recommended (p < 0.001); however, the frequency of PONV did not significantly differ between groups. Implementation of a validated and simplified PONV risk-assessment tool appeared to improve form completion rates and appropriate risk assessment; however, the rates of PONV remained similar and fewer patients received appropriate prophylaxis compared with patients assessed by the existing risk-assessment tool.
Clark, Sean; Iltis, Peter W
2008-05-01
Controlled laboratory study. To compare postural performance measures of athletes with those of nonathletes when completing the standard Sensory Organization Test (SOT) and a modified SOT that included dynamic head tilts (DHT-SOT). Authors of recently published research have suggested that modifications to the SOT protocol (eg, introduction of pitch and roll head tilts) may enhance the test's sensitivity when assessing postural stability in individuals with higher balance capabilities or with well-compensated sensory deficits. Nineteen athletes and 19 nonathletes (group) completed both the SOT and DHT-SOT (protocol). During the SOT, participants stood upright as steadily as possible for 20 seconds during each of 6 different sensory conditions. As a variation of the SOT, the DHT-SOT incorporated active pitch and roll head tilts into the SOT protocol. Four 2-way mixed-model analyses of variance (with protocol as the repeated factor) were performed to determine if the composite equilibrium score or the visual, vestibular, or somatosensory ratio scores differed between the 2 groups across the 2 testing protocols. Significant group-by-protocol interaction effects were present for both the composite equilibrium score and visual ratio. Follow-up simple main-effects analyses indicated that these measures did not differ between groups for the SOT protocol but were significantly different on the DHT-SOT. The addition of dynamic head tilts to the SOT protocol resulted in subtle differences in balance function between athletes and nonathletes. Athletes demonstrated an increased ability to adapt to sensory disruptions during the DHT-SOT. Therapists should consider including active pitch and roll head tilts to the SOT when evaluating individuals with higher balance function or to detect subtle deficits in balance function. Diagnosis, level 3b.
Pisu, Maria Carmela; Ponzio, Patrizia; Rovella, Chiara; Baravalle, Michela; Veronesi, Maria Cristina
2017-10-01
Objectives Although less often requested in comparison with dogs, the collection of semen in cats can be necessary for artificial insemination, for semen evaluation in tom cats used for breeding and for semen storage. Urethral catheterisation after pharmacological induction with medetomidine has proved to be useful for the collection of semen in domestic cats. However, most of the previously used protocols require the administration of high doses of medetomidine that can increase the risk of side effects, especially on the cardiovascular system. In routine clinical practice, one safe and useful injectable anaesthetic protocol for short-term clinical investigations or surgery in cats involves premedication with low intramuscular doses of dexmedetomidine with methadone, followed by intravenous propofol bolus injection. We aimed to assess the usefulness of this injectable anaesthetic protocol for semen collection, via urethral catheterisation, in domestic cats. Methods The study was performed on 38 purebred, adult cats, during the breeding season, and semen was collected via urethral catheterisation using an injectable anaesthesia protocol with methadone (0.2 mg/kg) and dexmedetomidine (5 µg/kg) premedication, followed by induction with propofol. Results The anaesthetic protocol used in the present study allowed the collection of large-volume semen samples, characterised by good parameters and without side effects. Conclusions and relevance The results from the present study suggest that the injectable anaesthetic protocol using methadone and dexmedetomidine premedication, followed by induction with propofol, could be suitable and safe for the collection of a good-quality semen sample, via urethral catheterisation, in domestic cats. It can therefore be used as an alternative to previous medetomidine-based sedation protocols.
2006-06-01
51 Appendix C. Promega Restriction Digest Protocol ....................................................53...Rsa1 Restriction Digest Results............................................................................180 9. DNA Base Pair Comparison...particular restriction endonuclease, the length of the fragments produced will differ when the DNA is digested with a restriction enzyme (Edwards
We compared three benthic macroinvertebrate sampling methods on the St. Croix, Wisconsin and Scioto Rivers in summer 2004 and 2005. EPA's newly developed, multi-habitat Large River Bioassessment Protocol (LR-BP) was compared to the multi-habitat method of the Minnesota Pollution...
USDA-ARS?s Scientific Manuscript database
Mechanography during the vertical jump may enhance screening and determining mechanistic causes for functional deficits that reduce physical performance. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the tes...
The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized proto...
Problem Solving Techniques for the Design of Algorithms.
ERIC Educational Resources Information Center
Kant, Elaine; Newell, Allen
1984-01-01
Presents model of algorithm design (activity in software development) based on analysis of protocols of two subjects designing three convex hull algorithms. Automation methods, methods for studying algorithm design, role of discovery in problem solving, and comparison of different designs of case study according to model are highlighted.…
COMPARISON OF TWO ARSENIC EXPOSURE ASSESSMENT PROTOCOLS IN A CHRONICALLY EXPOSED POPULATION
Consistent with the US EPA 1997 Arsenic Research Plan's emphasis on studies in US populations to obtain data to support a revised Maximum Contaminant Level (MCL) for arsenic, two studies were conducted in Millard County, Utah; the first in 1997 and a second in 1999. This locat...
Audio/ Videoconferencing Packages: Low Cost
ERIC Educational Resources Information Center
Treblay, Remy; Fyvie, Barb; Koritko, Brenda
2005-01-01
A comparison was conducted of "Voxwire MeetingRoom" and "iVocalize" v4.1.0.3, both Web-conferencing products using voice-over-Internet protocol (VoIP) to provide unlimited, inexpensive, international audio communication, and high-quality Web-conferencing fostering collaborative learning. The study used the evaluation criteria used in earlier…
Numerous laboratory test systems have been developed for the comparison of efficacy between various chemical oil dispersant formulations. However, for the assessment of chemical dispersant effectiveness under realistic sea state, test protocols are required to produce hydrodynam...
Environmental Health Promotion Interventions: Considerations for Preparation and Practice
ERIC Educational Resources Information Center
Kegler, Michelle Crozier; Miner, Kathleen
2004-01-01
Interventions to address current, future, and potential public health dilemmas, such as air pollution, urban sprawl, brown field reclamation, and threats of intentional toxic exposures would benefit from a synergy between the disciplines of environmental health and health education. A comparison between the Protocol for Assessing Community…
An Analysis of State and Local Alignment of Teacher Evaluation in Maryland
ERIC Educational Resources Information Center
Peterson, Serene N.
2014-01-01
This study explored the components of Maryland's newly-implemented teacher evaluation framework and compared state requirements with evaluations to three local school systems' evaluation procedures. The study sought to investigate the relationship between three evaluation protocols in comparison to the state requirements. Three local school…
Luna, Jorge M; Yip, Natalie; Pivovarov, Rimma; Vawdrey, David K
2016-08-01
Clinical teams in acute inpatient settings can greatly benefit from automated charting technologies that continuously monitor patient vital status. NewYork-Presbyterian has designed and developed a real-time patient monitoring system that integrates vital signs sensors, networking, and electronic health records, to allow for automatic charting of patient status. We evaluate the representativeness (a combination of agreement, safety and timing) of a core vital sign across nursing intensity care protocols for preliminary feasibility assessment. Our findings suggest an automated way of summarizing heart rate provides representation of true heart rate status and can facilitate alternatives approaches to burdensome manual nurse charting of physiological parameters.
Usage of the hybrid encryption in a cloud instant messages exchange system
NASA Astrophysics Data System (ADS)
Kvyetnyy, Roman N.; Romanyuk, Olexander N.; Titarchuk, Evgenii O.; Gromaszek, Konrad; Mussabekov, Nazarbek
2016-09-01
A new approach for constructing cloud instant messaging represented in this article allows users to encrypt data locally by using Diffie - Hellman key exchange protocol. The described approach allows to construct a cloud service which operates only by users encrypted messages; encryption and decryption takes place locally at the user party using a symmetric AES encryption. A feature of the service is the conferences support without the need for messages reecryption for each participant. In the article it is given an example of the protocol implementation on the ECC and RSA encryption algorithms basis, as well as a comparison of these implementations.
Comparison of Fixed Point Realisations between Inmetro and PTB
NASA Astrophysics Data System (ADS)
Santiago, J. F. N.; Petkovic, S. G.; Teixeira, R. N.; Noatsch, U.; Thiele-Krivoj, B.
2003-09-01
An interlaboratory comparison in the temperature range between -190 °C and 420 °C was organised between the National Institute of Quality, Normalisation and Industrial Quality (Inmetro), Brazil, and the Physikalisch Technische Bundesanstalt (PTB), Germany. This comparison followed the same protocol as the EUROMET project 552 comparison and was carried out in the years 2001-2002. A standard platinum resistance thermometer (SPRT) of 25 Ω was calibrated at the temperature fixed points of Ar, Hg, the triple point of water (TWP), Ga, In, Sn and Zn, with at least three realisations of each fixed point at both institutes. The uncertainty evaluation is given by Inmetro and some differences in the calibration procedures or in the measuring instruments used are described. The agreement between the results of laboratories was not in all cases within the combined uncertainties. Results of other comparisons are presented, which give additional information on the equivalence of the realised temperature scales.
Screening protocol for dysphagia in adults: comparison with videofluoroscopic findings.
Sassi, Fernanda C; Medeiros, Gisele C; Zilberstein, Bruno; Jayanthi, Shri Krishna; de Andrade, Claudia R F
2017-12-01
To compare the videofluoroscopic findings of patients with suspected oropharyngeal dysphagia with the results of a clinical screening protocol. A retrospective observational cohort study was conducted on all consecutive patients with suspected oropharyngeal dysphagia between March 2015 and February 2016 who were assigned to receive a videofluoroscopic assessment of swallowing. All patients were first submitted to videofluoroscopy and then to the clinical assessment of swallowing. The clinical assessment was performed within the first 24 hours after videofluoroscopy. The videofluoroscopy results were analyzed regarding penetration/aspiration using an 8-point multidimensional perceptual scale. The accuracy of the clinical protocol was analyzed using the sensitivity, specificity, likelihood ratios and predictive values. The selected sample consisted of 50 patients. The clinical protocol presented a sensitivity of 50% and specificity of 95%, with an accuracy of 88%. "Cough" and "wet-hoarse" vocal quality after/during swallowing were clinical indicators that appeared to correctly identify the presence of penetration/aspiration risk. The clinical protocol used in the present study is a simple, rapid and reliable clinical assessment. Despite the absence of a completely satisfactory result, especially in terms of the sensitivity and positive predictive values, we suggest that lower rates of pneumonia can be achieved using a formal dysphagia screening method.
Miniaturization of the Clonogenic Assay Using Confluence Measurement
Mayr, Christian; Beyreis, Marlena; Dobias, Heidemarie; Gaisberger, Martin; Pichler, Martin; Ritter, Markus; Jakab, Martin; Neureiter, Daniel; Kiesslich, Tobias
2018-01-01
The clonogenic assay is a widely used method to study the ability of cells to ‘infinitely’ produce progeny and is, therefore, used as a tool in tumor biology to measure tumor-initiating capacity and stem cell status. However, the standard protocol of using 6-well plates has several disadvantages. By miniaturizing the assay to a 96-well microplate format, as well as by utilizing the confluence detection function of a multimode reader, we here describe a new and modified protocol that allows comprehensive experimental setups and a non-endpoint, label-free semi-automatic analysis. Comparison of bright field images with confluence images demonstrated robust and reproducible detection of clones by the confluence detection function. Moreover, time-resolved non-endpoint confluence measurement of the same well showed that semi-automatic analysis was suitable for determining the mean size and colony number. By treating cells with an inhibitor of clonogenic growth (PTC-209), we show that our modified protocol is suitable for comprehensive (broad concentration range, addition of technical replicates) concentration- and time-resolved analysis of the effect of substances or treatments on clonogenic growth. In summary, this protocol represents a time- and cost-effective alternative to the commonly used 6-well protocol (with endpoint staining) and also provides additional information about the kinetics of clonogenic growth. PMID:29510509
NASA Astrophysics Data System (ADS)
Gordon, Isabel Jiménez; Genies, Sylvie; Si Larbi, Gregory; Boulineau, Adrien; Daniel, Lise; Alias, Mélanie
2016-03-01
Understanding ageing mechanisms of Li-ion batteries is essential for further optimizations. To determine performance loss causes, post-mortem analyses are commonly applied. For each type of post-mortem test, different sample preparation protocols are adopted. However, reports on the reliability of these protocols are rare. Herein, Li-ion pouch cells with LiNi1/3Mn1/3Co1/3O2 - polyvinylidene fluoride positive electrode, graphite-carboxymethyl cellulose-styrene rubber negative electrode and LiPF6 - carbonate solvents mixture electrolyte, are opened and electrodes are recovered following a specified protocol. Negative and positive symmetric cells are assembled and their impedances are recorded. A signal analysis is applied to reconstruct the Li-ion pouch cell impedance from the symmetric cells, then comparison against the pouch cell true impedance allows the evaluation of the sample preparation protocols. The results are endorsed by Transmission Electronic Microscopy (TEM) and Gas Chromatography - Mass Spectrometry (GC-MS) analyses. Carbonate solvents used to remove the salt impacts slightly the surface properties of both electrodes. Drying electrodes under vacuum at 25 °C produces an impedance increase, particularly very marked for the positive electrode. Drying at 50 °C under vacuum or/and exposition to the anhydrous room atmosphere is very detrimental.
Circadian temperature rhythms of older people
NASA Technical Reports Server (NTRS)
Monk, T. H.; Buysse, D. J.; Reynolds, C. F. 3rd; Kupfer, D. J.; Houck, P. R.
1995-01-01
This collection of studies had the aim of exploring whether older (77+ years) men and women have circadian body temperature rhythms different from those of younger adults. A total of 20 older men and 28 older women were compared with either 22 young men or 14 middle-aged men in four protocols; all but the first protocol using a subset of the sample. The four protocols were: 1) 24 h, and 2) 72 h data collections on a normal laboratory routine (sleeping at night); 3) between 36 h and 153 h of field data collection at home; and 4) 36 h of a constant conditions routine (wakeful bedrest under temporal isolation) in the laboratory. There was some evidence for an age-related phase advance in temperature rhythm, especially for the older men on a normal routine, though this was not present in the constant conditions protocol, where 5 of the older subjects showed major delays in the timing of the body temperature trough (10:00 or later). There was no statistically significant evidence from any of the protocols that older subjects generally had lower temperature rhythm amplitudes than younger adults. Only when older men were compared with younger men in 24-h rhythm amplitude by simple t-test did any comparison involving amplitude achieve statistical significance (p < 0.05).
Vidotto, Laís Silva; Bigliassi, Marcelo; Alencar, Tatiane Romanini Rodrigues; Silva, Thaísa Maria Santos; Probst, Vanessa Suziane
2015-07-01
To compare the acute effects of a standardized physiotherapy protocol versus a typical non-standardized physiotherapy protocol on pain and performance of patients undergoing alveolar bone graft (ABG). Sixteen patients (9 males; 12 [11-13] years) with cleft lip and palate undergoing ABG were allocated into two groups: (1) experimental group--EG (standardized physiotherapy protocol); and (2) control group--CG (typical, non-standardized physiotherapy treatment). Range of motion, muscle strength, gait speed, and pain level were assessed prior to surgical intervention (PRE), as well as on the first, second, and third post-operative days (1st, 2nd, and 3rd PO, respectively). Recovery with respect to range of motion of hip flexion was more pronounced in the EG (64.6 ± 11.0°) in comparison to the CG (48.5 ± 17.7° on the 3rd PO; p < 0.05). In addition, less pain was observed in the EG (0 [0-0.2] versus 2 [0.7-3] in the CG on the 3rd PO; p < 0.05). A standardized physiotherapy protocol appears to be better than a non-standardized physiotherapy protocol for acute improvement of range of motion of hip flexion and for reducing pain in patients undergoing ABG.
Weitzman, Vanessa N; Engmann, Lawrence; DiLuigi, Andrea; Maier, Donald; Nulsen, John; Benadiva, Claudio
2009-07-01
To compare IVF outcomes in poor-responder patients undergoing stimulation after luteal phase E(2) patch/GnRH antagonist (LPG) protocol versus microdose GnRH agonist protocol. Retrospective analysis. University-based IVF center. Forty-five women undergoing ovarian stimulation for IVF using the LPG protocol were compared with 76 women stimulated with the microdose GnRH agonist protocol from May 2005 to April 2006. Cancellation rate, number of oocytes retrieved, and clinical pregnancy rates. The mean number of oocytes (9.1 +/- 4.1 vs. 8.9 +/- 4.3) and mature oocytes (6.7 +/- 3.5 vs. 6.8 +/- 3.1) retrieved were similar, as were the fertilization rates (70.0% +/- 24.2% vs. 69.9% +/- 21.5%) and the number of embryos transferred (2.5 +/- 1.1 vs. 2.7 +/- 1.3). The cancellation rate was not significantly different between the groups (13/45, 28.9% vs. 23/76, 30.3%). Likewise, there were no significant differences among the implantation rate (15.0% vs. 12.5%), clinical pregnancy rate (43.3% vs. 45.1%), and ongoing pregnancy rate per transfer (33.3% vs. 26.0%) between both groups. This study demonstrates that the use of an E(2) patch and a GnRH antagonist during the preceding luteal phase in patients with a history of failed cycles can provide similar IVF outcomes when compared with the microdose GnRH agonist protocol.
Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G
2006-06-01
Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (
Grissa, Ibtissem; Vergnaud, Gilles; Pourcel, Christine
2009-01-01
Clustered regularly interspaced short palindromic repeats (CRISPRs) are DNA sequences composed of a succession of repeats (23- to 47-bp long) separated by unique sequences called spacers. Polymorphism can be observed in different strains of a species and may be used for genotyping. We describe protocols and bioinformatics tools that allow the identification of CRISPRs from sequenced genomes, their comparison, and their component determination (the direct repeats and the spacers). A schematic representation of the spacer organization can be produced, allowing an easy comparison between strains.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tfaily, Malak M.; Chu, Rosalie K.; Toyoda, Jason
A vast number of organic compounds are present in soil organic matter (SOM) and play an important role in the terrestrial carbon cycle, facilitate interactions between organisms, and represent a sink for atmospheric CO2. The diversity of different SOM compounds and their molecular characteristics is a function of the organic source material and biogeochemical history. By understanding how SOM composition changes with sources and the processes by which it is biogeochemically altered in different terrestrial ecosystems, it may be possible to predict nutrient and carbon cycling, response to system perturbations, and impact of climate change will have on SOM composition.more » In this study, a sequential chemical extraction procedure was developed to reveal the diversity of organic matter (OM) in different ecosystems and was compared to the previously published protocol using parallel solvent extraction (PSE). We compared six extraction methods using three sample types, peat soil, spruce forest soil and river sediment, so as to select the best method for extracting a representative fraction of organic matter from soils and sediments from a wide range of ecosystems. We estimated the extraction yield of dissolved organic carbon (DOC) by total organic carbon analysis, and measured the composition of extracted OM using high resolution mass spectrometry. This study showed that OM composition depends primarily on soil and sediment characteristics. Two sequential extraction protocols, progressing from polar to non-polar solvents, were found to provide the highest number and diversity of organic compounds extracted from the soil and sediments. Water (H2O) is the first solvent used for both protocols followed by either co-extraction with methanol-chloroform (MeOH-CHCl3) mixture, or acetonitrile (ACN) and CHCl3 sequentially. The sequential extraction protocol developed in this study offers improved sensitivity, and requires less sample compared to the PSE workflow where a new sample is used for each solvent type. Furthermore, a comparison of SOM composition from the different sample types revealed that our sequential protocol allows for ecosystem comparisons based on the diversity of compounds present, which in turn could provide new insights about source and processing of organic compounds in different soil and sediment types.« less
Tfaily, Malak M; Chu, Rosalie K; Toyoda, Jason; Tolić, Nikola; Robinson, Errol W; Paša-Tolić, Ljiljana; Hess, Nancy J
2017-06-15
A vast number of organic compounds are present in soil organic matter (SOM) and play an important role in the terrestrial carbon cycle, facilitate interactions between organisms, and represent a sink for atmospheric CO 2 . The diversity of different SOM compounds and their molecular characteristics is a function of the organic source material and biogeochemical history. By understanding how SOM composition changes with sources and the processes by which it is biogeochemically altered in different terrestrial ecosystems, it may be possible to predict nutrient and carbon cycling, response to system perturbations, and impact of climate change will have on SOM composition. In this study, a sequential chemical extraction procedure was developed to reveal the diversity of organic matter (OM) in different ecosystems and was compared to the previously published protocol using parallel solvent extraction (PSE). We compared six extraction methods using three sample types, peat soil, spruce forest soil and river sediment, so as to select the best method for extracting a representative fraction of organic matter from soils and sediments from a wide range of ecosystems. We estimated the extraction yield of dissolved organic carbon (DOC) by total organic carbon analysis, and measured the composition of extracted OM using high resolution mass spectrometry. This study showed that OM composition depends primarily on soil and sediment characteristics. Two sequential extraction protocols, progressing from polar to non-polar solvents, were found to provide the highest number and diversity of organic compounds extracted from the soil and sediments. Water (H 2 O) is the first solvent used for both protocols followed by either co-extraction with methanol-chloroform (MeOH-CHCl 3 ) mixture, or acetonitrile (ACN) and CHCl 3 sequentially. The sequential extraction protocol developed in this study offers improved sensitivity, and requires less sample compared to the PSE workflow where a new sample is used for each solvent type. Furthermore, a comparison of SOM composition from the different sample types revealed that our sequential protocol allows for ecosystem comparisons based on the diversity of compounds present, which in turn could provide new insights about source and processing of organic compounds in different soil and sediment types. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Xuebo
2009-01-01
In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Campoy, Irene; Lanau, Lucia; Altadill, Tatiana; Sequeiros, Tamara; Cabrera, Silvia; Cubo-Abert, Montserrat; Pérez-Benavente, Assumpción; Garcia, Angel; Borrós, Salvador; Santamaria, Anna; Ponce, Jordi; Matias-Guiu, Xavier; Reventós, Jaume; Gil-Moreno, Antonio; Rigau, Marina; Colas, Eva
2016-06-18
Uterine aspirates are used in the diagnostic process of endometrial disorders, yet further applications could emerge if its complex milieu was simplified. Exosome-like vesicles isolated from uterine aspirates could become an attractive source of biomarkers, but there is a need to standardize isolation protocols. The objective of the study was to determine whether exosome-like vesicles exist in the fluid fraction of uterine aspirates and to compare protocols for their isolation, characterization, and analysis. We collected uterine aspirates from 39 pre-menopausal women suffering from benign gynecological diseases. The fluid fraction of 27 of those aspirates were pooled and split into equal volumes to evaluate three differential centrifugation-based procedures: (1) a standard protocol, (2) a filtration protocol, and (3) a sucrose cushion protocol. Characterization of isolated vesicles was assessed by electron microscopy, nanoparticle tracking analysis and immunoblot. Specifically for RNA material, we evaluate the effect of sonication and RNase A treatment at different steps of the protocol. We finally confirmed the efficiency of the selected methods in non-pooled samples. All protocols were useful to isolate exosome-like vesicles. However, the Standard procedure was the best performing protocol to isolate exosome-like vesicles from uterine aspirates: nanoparticle tracking analysis revealed a higher concentration of vesicles with a mode of 135 ± 5 nm, and immunoblot showed a higher expression of exosome-related markers (CD9, CD63, and CD81) thus verifying an enrichment in this type of vesicles. RNA contained in exosome-like vesicles was successfully extracted with no sonication treatment and exogenous nucleic acids digestion with RNaseA, allowing the analysis of the specific inner cargo by Real-Time qPCR. We confirmed the existence of exosome-like vesicles in the fluid fraction of uterine aspirates. They were successfully isolated by differential centrifugation giving sufficient proteomic and transcriptomic material for further analyses. The Standard protocol was the best performing procedure since the other two tested protocols did not ameliorate neither yield nor purity of exosome-like vesicles. This study contributes to establishing the basis for future comparative studies to foster the field of biomarker research in gynecology.
Perlmutter, A S; Tran, V-T; Dechartres, A; Ravaud, P
2017-04-01
Protocols are often unavailable to peer-reviewers and readers. To detect outcome reporting bias (ORB), readers usually have to resort to publicly available descriptions of study design such as public clinical trial registries. We compared primary outcomes in protocols, ClinicalTrials.gov and publications of oncology trials and evaluated the use of ClinicalTrials.gov as compared with protocols in detecting discrepancies between planned and published outcomes. We searched for phase III oncology trials registered in ClinicalTrials.gov and published in the Journal of Clinical Oncology and New England Journal of Medicine between January 2014 and June 2015. We extracted primary outcomes reported in the protocol, ClinicalTrials.gov and the publication. First, we assessed the quality of primary outcome descriptions by using a published framework. Second, we evaluated modifications of primary outcomes between each source. Finally, we evaluated the agreement, specificity and sensitivity of detecting modifications between planned and published outcomes by using protocols or ClinicalTrials.gov. We included 65 trials, with 81 primary outcomes common among the 3 sources. The proportion of primary outcomes reporting all items from the framework was 73%, 22%, and 75% for protocols, ClinicalTrials.gov and publications, respectively. Eight (12%) trials presented a discrepancy between primary outcomes reported in the protocol and in the publication. Twelve (18.5%) trials presented a discrepancy between primary outcomes registered at ClinicalTrials.gov and in publications. We found a moderate agreement in detecting discrepant reporting of outcomes by using protocols or ClinicalTrials.gov [κ = 0.53, 95% confidence interval (0.25-0.81)]. Using ClinicalTrials.gov to detect discrepant reporting of outcomes showed high specificity (89.5%) but lacked sensitivity (75%) as compared with use of protocols. In oncology trials, primary outcome descriptions in ClinicalTrials.gov are often of low quality and may not reflect what is in the protocol, thus limiting the detection of modifications between planned and published outcomes. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Probst, Alexander; Facius, Rainer; Wirth, Reinhard; Moissl-Eichinger, Christine
2010-01-01
In order to meet planetary-protection requirements, culturable bacterial spore loads are measured representatively for the total microbial contamination of spacecraft. However, the National Aeronautics and Space Administration's (NASA's) cotton swab protocols for spore load determination have not changed for decades. To determine whether a more efficient alternative was available, a novel swab was evaluated for recovery of different Bacillus atrophaeus spore concentrations on stainless steel and other surfaces. Two protocols for the nylon-flocked swab (NFS) were validated and compared to the present NASA standard protocol. The results indicate that the novel swab protocols recover 3- to 4-fold more (45.4% and 49.0% recovery efficiency) B. atrophaeus spores than the NASA standard method (13.2%). Moreover, the nylon-flocked-swab protocols were superior in recovery efficiency for spores of seven different Bacillus species, including Bacillus anthracis Sterne (recovery efficiency, 20%). The recovery efficiencies for B. atrophaeus spores from different surfaces showed a variation from 5.9 to 62.0%, depending on the roughness of the surface analyzed. Direct inoculation of the swab resulted in a recovery rate of about 80%, consistent with the results of scanning electron micrographs that allowed detailed comparisons of the two swab types. The results of this investigation will significantly contribute to the cleanliness control of future life detection missions and will provide significant improvement in detection of B. anthracis contamination for law enforcement and security efforts. PMID:20543054
Ren, Jianzhi; Sha, Aiguo; Han, Dongmei; Li, Ping; Geng, Jie; Ma, Chaihui
2014-07-01
To evaluate the effects of a prolonged duration of gonadotropin-releasing hormone agonist (GnRH-a) in pituitary down-regulation for controlled ovarian hyperstimulation (COH) on the live-birth rate in nonendometriotic women undergoing in vitro fertilization and embryo transfer (IVF-ET). Retrospective cohort study. University-affiliated hospital. Normogonadotropic women undergoing IVF. Three hundred seventy-eight patients receiving a prolonged pituitary down-regulation with GnRH-a before ovarian stimulation and 422 patients receiving a GnRH-a long protocol. Live-birth rate per fresh ET. In comparison with the long protocol, the prolonged down-regulation protocol required a higher total dose of gonadotropins. A lower serum luteinizing hormone (LH) level on the starting day of gonadotropin and the day of human chorionic gonadotropin (hCG) and a fewer number of oocytes and embryos were observed in the prolonged down-regulation protocol. However, the duration of stimulation and number of high-quality embryos were comparable between the two groups. A statistically significantly higher implantation rate (50.27% vs. 39.69%), clinical pregnancy rate (64.02% vs. 56.87%) and live-birth rate per fresh transfer cycle (55.56% vs. 45.73%) were observed in the prolonged protocol. Prolonged down-regulation in a GnRH-a protocol might increase the live-birth rates in normogonadotropic women. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
2012-01-01
Background Management of cancer treatment-related symptoms is an important safety issue given that symptoms can become life-threatening and often occur when patients are at home. With funding from the Canadian Partnership Against Cancer, a pan-Canadian steering committee was established with representation from eight provinces to develop symptom protocols using a rigorous methodology (CAN-IMPLEMENT©). Each protocol is based on a systematic review of the literature to identify relevant clinical practice guidelines. Protocols were validated by cancer nurses from across Canada. The aim of this study is to build an effective and sustainable approach for implementing evidence-informed protocols for nurses to use when providing remote symptom assessment, triage, and guidance in self-management for patients experiencing symptoms while undergoing cancer treatments. Methods A prospective mixed-methods study design will be used. Guided by the Knowledge to Action Framework, the study will involve (a) establishing an advisory knowledge user team in each of three targeted settings; (b) assessing factors influencing nurses’ use of protocols using interviews/focus groups and a standardized survey instrument; (c) adapting protocols for local use, ensuring fidelity of the content; (d) selecting intervention strategies to overcome known barriers and implementing the protocols; (e) conducting think-aloud usability testing; (f) evaluating protocol use and outcomes by conducting an audit of 100 randomly selected charts at each of the three settings; and (g) assessing satisfaction with remote support using symptom protocols and change in nurses’ barriers to use using survey instruments. The primary outcome is sustained use of the protocols, defined as use in 75% of the calls. Descriptive analysis will be conducted for the barriers, use of protocols, and chart audit outcomes. Content analysis will be conducted on interviews/focus groups and usability testing with comparisons across settings. Discussion Given the importance of patient safety, patient-centered care, and delivery of quality services, learning how to effectively implement evidence-informed symptom protocols in oncology healthcare services is essential for ensuring safe, consistent, and effective care for individuals with cancer. This study is likely to have a significant contribution to the delivery of remote oncology services, as well as influence symptom management by patients at home. PMID:23164244
Ryan, Gareth; Dooley, Joe; Windrim, Rory; Bollinger, Megan; Gerber Finn, Lianne; Kelly, Len
2017-06-01
To describe/analyse a novel, community-based prenatal monitoring protocol for opioid-exposed pregnancies developed by our centre in 2014 to optimize prenatal care for this population. A literature review of published monitoring protocols for this population is also presented. Retrospective comparison of pre-protocol (n = 215) and post-protocol (n = 251) cohorts. Medline and Embase were searched between 2000-2016 using MeSH terms: [fetal monitoring OR prenatal care] AND [opioid-related disorders OR substance-related disorders] in Medline and [fetal monitoring OR prenatal care] AND [opiate addiction OR substance abuse] in Embase, producing 518 results. Thirteen studies included protocols for monitoring opioid-exposed pregnancies. No comprehensive monitoring protocols with high-quality supporting evidence were found. We evaluated 466 opioid-exposed pregnancies, 215 before and 251 after introduction of the protocol. Since implementation, there was a significant increase in the number of opioid-exposed patients who have underwent urine drug screening (72.6% to 89.2%, P < 0.0001); a significant reduction in the number of urine drug screenings positive for illicit opioids (50.2% to 29.1%, P < 0.0001); and a significant increase in the number of patients who discontinued illicit opioid use by the time of delivery (24.7% to 39.4%, P < 0.01). There was no difference in the CS rate (27.4% vs. 26.3%, P > 0.05). There were no observed differences in the rate of preterm birth, birth weight <2500 g, or Apgar score <7 (P > 0.05). Care of women with increased opioid use during pregnancy is an important but under-studied health issue. A novel protocol for focused antenatal care provision for women with opioid-exposed pregnancies improves standard of care and maternal/fetal outcomes. Copyright © 2017. Published by Elsevier Inc.
Is the flexible GnRH antagonist protocol better suited for fresh eSET cycles?
Dahdouh, Elias M; Gomes, Francisco L A F; Granger, Louis; Carranza-Mamane, Belina; Faruqi, Faez; Kattygnarath, Tiao-Virirak; St-Michel, Pierre
2014-10-01
This study was performed to evaluate the efficacy of the flexible GnRH antagonist protocol in comparison with the long GnRH agonist protocol in elective single embryo transfer (eSET) practice. It was conducted in a publicly funded in vitro fertilization program. We performed a prospective cohort analysis of data from a private infertility clinic from August 2010 to August 2011. Three hundred fourteen women with normal ovarian reserve and undergoing fresh eSET cycles were included. Sixty-four women underwent follicular stimulation using a flexible GnRH antagonist protocol, and 250 underwent stimulation with a standard long mid-luteal GnRH agonist protocol. Implantation rates (35.9% in the GnRH antagonist group and 29.6% in the GnRH agonist group, P = 0.5) and ongoing pregnancy rates (32.8% in the GnRH antagonist group and 28.8% in the GnRH agonist group, P = 0.5) were equivalent in both groups. The duration of stimulation (9.8 ± 2 days vs. 10.7 ± 1.8 days, P < 0.001) and total FSH dose required (2044 vs. 2775 IU, P < 0.001) were lower in the GnRH antagonist group than in the GnRH agonist group. The number of mature oocytes (6.0 vs. 10.0, P < 0. 001) and number of embryos (5.0 vs. 7.0, P < 0.001) were also lower in GnRH antagonist group. However, the number of embryos cryopreserved was similar in both groups (median 2.0, P = 0.3). In women undergoing in vitro fertilization, the flexible GnRH antagonist protocol yields implantation and ongoing pregnancy rates that are similar to the long GnRH agonist protocol, and requires lower doses of gonadotropins and a shorter duration of treatment. The flexible GnRH antagonist protocol appears to be the protocol of choice for an eSET IVF program.
Verger, Antoine; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, François; Koehl, Grégoire; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Roch, Véronique; Le Guludec, Dominique; Karcher, Gilles; Marie, Pierre-Yves
2013-02-01
The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving (201)Tl (n = 120) or (99m)Tc-sestamibi injected at low dose at stress ((99m)Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ((99m)Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, (201)Tl 92 %, (99m)Tc-Low 86 %, (99m)Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the (201)Tl or (99m)Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shea, S; Diak, A; Surucu, M
2015-06-15
Purpose: To investigate the effect of readout bandwidth and voxel size on the appearance of distortion artifacts caused by a titanium brachytherapy applicator. Methods: An acrylic phantom was constructed to rigidly hold a MR conditional, titanium Fletcher-Suit-Delclos-style applicator set (Varian Medical Systems) for imaging on CT (Philips Brilliance) and 1.5T MRI (Siemens Magnetom Aera). Several variants of MRI parameters were tried for 2D T2-weighted turbo spin echo imaging in comparison against the standard clinical protocol with the criteria to keep relative SNR loss less than 20% and imaging time as short as possible. Two 3D sequences were also used formore » comparison with similar parameters. The applicator tandem was segmented on axial CT images (0.4×0.4×1.5mm {sup 3} resolution) and the CT images were registered to the 3D MR images in Eclipse (Varian). The applicator volume was then overlaid on all MRI sets in 3D-Slicer and distances were measured from the tandem tip to the MRI artifact edge in right/left/superior and anterior/posterior/superior directions from coronal and sagittal 2D acquisitions, respectively, or 3D data reformats. Artifact regions were also manually contoured in coronal/sagittal orientations for area measurements. Results: As would be expected, reductions in voxel size and increases in readout bandwidth reduced artifact size (average max artifact length decreased by 0.95 mm and average max area decrease by 0.27 cm{sup 2}). Interestingly, bandwidth increases yielded reductions in area (0.19 cm{sup 2}) and in distance measurements (1 mm) even with voxel increases, as compared to a standard protocol. This could be useful when high performance protocols are not feasible due to long imaging times. Conclusion: We have characterized artifacts caused by cervical brachytherapy applicator across multiple sequence parameters at 1.5T. Future work will focus on finalizing an optimal protocol that balances artifact reduction with imaging time and then testing this new protocol in patients.« less
A comparison of two methods of eluting insect DNA from Flinders Technology Associates Cards
USDA-ARS?s Scientific Manuscript database
Flinders Technology Associates (FTA) technology lyses cells and stabilizes DNA for room-temperature storage in a single step but it has been infrequently used with arthropods. One possible reason is the paucity of quick and inexpensive protocols to subsequently elute the DNA from the card matrix. Th...
The Lifestyles of Blind, Low Vision, and Sighted Youths: A Quantitative Comparison.
ERIC Educational Resources Information Center
Wolffe, K.; Sacks, S. Z.
1997-01-01
Analysis of interviews and time-diary protocols with 48 students (16 blind, 16 low-vision, and 16 sighted), ages 15-21, and their parents focused on four lifestyle areas: academic involvement and performance, daily living and personal care activities, recreation and leisure activities, and work and vocational experiences. Similarities and…
To comply with legal mandates, meet local management objectives, or both, many federal, state, and tribal organizations have monitoring groups that assess stream habitat at different scales. This myriad of groups has difficulty sharing data and scaling up stream habitat assessmen...
Stream macroinvertebrate collection methods described in the Rapid Bioassessment Protocols (RBPs) have been used widely throughout the U.S. The first edition of the RBP manual in 1989 described a single habitat approach that focused on riffles and runs, where macroinvertebrate d...
Review of soil organic carbon measurement protocols: A US and Brazil comparison and recommendation
USDA-ARS?s Scientific Manuscript database
The global soil carbon pool represents three to four times the amount of carbon stored in the atmosphere and in living biomass. Accurate measurements of changes in soil carbon are important to understand the impacts of current land management and to identify opportunities to enhance carbon sequestra...
COMPARISON OF THE EFFECT OF AMERICAN BISON AND CATTLE ON PASTURE AND DIRECT ACCESS STREAMS
If the Bison are managed in a low impact method then we can count on meat that is free of antibiotics, added hormones, and other industry byproducts. In fact, Federal regulations prohibit the use of artificial growth hormones in bison, and industry protocols prohibit the use ...
A Comparison of Hamster Anesthetics and Their Effect on Mosquito Blood Feeding
USDA-ARS?s Scientific Manuscript database
Hamsters or mice are often anesthetized when they are used as the hosts for insect feeding experiments. An experiment was done to determine if there was a difference in mosquito blood feeding success when fed on hamsters anesthetized using two commonly used protocols. The number of blood-fed females...
Financial Indicators of Reduced Impact Logging Performance in Brazil: Case Study Comparisons
Thomas P. Holmes; Frederick Boltz; Douglas R. Carter
2001-01-01
Indicators of financial performance are compared for three case studies in the Brazilian Amazon. Each case study presents parameters obtained from monitoring initial harvest entries into primary forests for reduced impact logging (RIL) and conventional logging (CL) operations. Differences in cost definitions and data collection protocols complicate the analysis, and...
Karen Kuers
2002-01-01
Plant species richness in 24 year-old planted lobiolly pine (Pinus taeda L.), eastern white pine (Pinus strobus L.), yellow-poplar (Liriodendron tulipifera L.), naturally regenerated hardwoods, and mature hardwoods was compared using the North Carolina Vegetation Survey protocol. Comparisons were made in...
World-Wide Web: The Information Universe.
ERIC Educational Resources Information Center
Berners-Lee, Tim; And Others
1992-01-01
Describes the World-Wide Web (W3) project, which is designed to create a global information universe using techniques of hypertext, information retrieval, and wide area networking. Discussion covers the W3 data model, W3 architecture, the document naming scheme, protocols, document formats, comparison with other systems, experience with the W3…
Paediatric oral peanut challenges: a comparison of practice in London and western Switzerland.
Ludman, S; Wassenberg, J; Du Toit, G; Fox, A T; Lack, G; Eigenmann, P A
2013-04-01
There are guidelines on how to develop a food challenge protocol, but at present there is no gold standard guidance on method, and separate units produce differing protocols. We performed a retrospective analysis of 200 patients' data from the paediatric allergy units in Lausanne and Geneva, Western Switzerland, and St Thomas' Hospital (STH), UK. St Thomas' Hospital has a younger cohort with a lower overall mean spIgE (2.36 kU/l vs. 8.00 kU/l, P = 0.004). The target peanut protein volumes differed: Switzerland 4.4 g vs. STH 8.4 g. Despite this, the dose actually achieved in positive challenges was not significantly different (2.33 g vs. 1.49 g, P = 0.16). 26% of challenges reacted at 4 g or more of peanut protein. The differences in results highlight how the variation in reasoning behind food challenge alters the outcome. Standardization of food challenges would allow easy comparison between hospitals and geographical areas for research purposes. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Fast charge implications: Pack and cell analysis and comparison
NASA Astrophysics Data System (ADS)
Tanim, Tanvir R.; Shirk, Matthew G.; Bewley, Randy L.; Dufek, Eric J.; Liaw, Bor Yann
2018-03-01
This study investigates the effect of 50-kW (about 2C) direct current fast charging on a full-size battery electric vehicle's battery pack in comparison to a pack exclusively charged at 3.3 kW, which is the common alternating current Level 2 charging power level. Comparable scaled charging protocols are also independently applied to individual cells at three different temperatures, 20 °C, 30 °C, and 40 °C, to perform a comparative analysis with the packs. Dominant cell-level aging modes were identified through incremental capacity analysis and compared with full packs to gain a clear understanding of additional key factors that affect pack aging. While the cell-level study showed a minor impact on performance due to direct current fast charging, the packs showed a significantly higher rate of capacity fade under similar charging protocols. This indicates that pack-level aging cannot be directly extrapolated from cell evaluation. Delayed fast charging, completing shortly before discharge, was found to have less of an impact on battery degradation than conventional alternating current Level 2 charging.
Yoshitake, Tadayuki; Giacomelli, Michael G; Cahill, Lucas C; Schmolze, Daniel B; Vardeh, Hilde; Faulkner-Jones, Beverly E; Connolly, James L; Fujimoto, James G
2016-12-01
Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue.
Yoshitake, Tadayuki; Giacomelli, Michael G.; Cahill, Lucas C.; Schmolze, Daniel B.; Vardeh, Hilde; Faulkner-Jones, Beverly E.; Connolly, James L.; Fujimoto, James G.
2016-01-01
Abstract. Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue. PMID:28032121
Violanti, S; Fraschetta, M; Adda, S; Caputo, E
2009-12-01
Within the framework of Environmental Agencies system's activities, coordinated by ISPRA (superior institute for environmental protection and research), a comparison among measurements was designed and accomplished, in order to go into depth on the matter of measurement problems and to evaluate magnetic field at power frequencies. These measurements have been taken near medium voltage /low voltage transformer substation. This project was developed with the contribution of several experts who belong to different Regional Agencies. In three of these regions, substations having specific international standard characteristics were chosen; then a measurement and data analysis protocol was arranged. Data analysis showed a good level of coherence among results obtained by different laboratories. However, a range of problems emerged, either during the protocol predisposition and definition of the data analysis procedure or during the execution of measures and data reprocessing, because of the spatial and temporal variability of magnetic field. These problems represent elements of particular interest in determining a correct measurement methodology, whose purpose is the comparison with limits of exposure, attention values and quality targets.
Comparative Analysis of Single-Cell RNA Sequencing Methods.
Ziegenhain, Christoph; Vieth, Beate; Parekh, Swati; Reinius, Björn; Guillaumet-Adkins, Amy; Smets, Martha; Leonhardt, Heinrich; Heyn, Holger; Hellmann, Ines; Enard, Wolfgang
2017-02-16
Single-cell RNA sequencing (scRNA-seq) offers new possibilities to address biological and medical questions. However, systematic comparisons of the performance of diverse scRNA-seq protocols are lacking. We generated data from 583 mouse embryonic stem cells to evaluate six prominent scRNA-seq methods: CEL-seq2, Drop-seq, MARS-seq, SCRB-seq, Smart-seq, and Smart-seq2. While Smart-seq2 detected the most genes per cell and across cells, CEL-seq2, Drop-seq, MARS-seq, and SCRB-seq quantified mRNA levels with less amplification noise due to the use of unique molecular identifiers (UMIs). Power simulations at different sequencing depths showed that Drop-seq is more cost-efficient for transcriptome quantification of large numbers of cells, while MARS-seq, SCRB-seq, and Smart-seq2 are more efficient when analyzing fewer cells. Our quantitative comparison offers the basis for an informed choice among six prominent scRNA-seq methods, and it provides a framework for benchmarking further improvements of scRNA-seq protocols. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yoshitake, Tadayuki; Giacomelli, Michael G.; Cahill, Lucas C.; Schmolze, Daniel B.; Vardeh, Hilde; Faulkner-Jones, Beverly E.; Connolly, James L.; Fujimoto, James G.
2016-12-01
Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue.
2014-01-01
Background Patients with type 2 diabetes (T2DM) are subjected to reduction in the quality and oxidative capacity of muscles. The effect of duration of diabetes on the muscle endurance response is not clear and strength as well. Objective The aim of this study was the assessment of strength and endurance of knee extensor and flexor in the patients with T2DM < 10 and T2DM > 10 years in comparison with age, sex, BMI, ABI and PAI-matched health control subjects. Methods Isometric maximal peak torque (MPT) of knee extensor and flexor before and after 40 isokinetic repetitions with velocity of 150 degree/s were recorded in 18 patients with T2DM < 10 Y , 12 patients with T2DM > 10 Y and 20 matched health control (HC) groups. Results Both diabetic patient groups had significant lower isometric and isotonic knee extensor and flexor strength than HC. The endurance indices indicated that whereas the isometric MPT of flexor movement was reduced after isokinetic protocol in the both patient groups in comparison with HC, the less decline was seen in the isotonic torque and work during isokinetic protocol in the T2DM > 10 Y group in comparison with two other groups. The HbA1c and FPG were significantly correlated with strength not with endurance indices. Conclusions It seems the progression of diabetes accompanied with vascular, neural and muscular deficits activate, some adaptive and compensatory processes which can maintain muscle performance. PMID:24476108
Forestieri, Patrícia; Guizilini, Solange; Peres, Monique; Bublitz, Caroline; Bolzan, Douglas W.; Rocco, Isadora S.; Santos, Vinícius B.; Moreira, Rita Simone L.; Breda, João R.; de Almeida, Dirceu R.; Carvalho, Antonio Carlos de C.; Arena, Ross; Gomes, Walter J.
2016-01-01
Objective The purpose of this study was to evaluate the effect of a cycle ergometer exercise program on exercise capacity and inspiratory muscle function in hospitalized patients with heart failure awaiting heart transplantation with intravenous inotropic support. Methods Patients awaiting heart transplantation were randomized and allocated prospectively into two groups: 1) Control Group (n=11) - conventional protocol; and 2) Intervention Group (n=7) - stationary cycle ergometer exercise training. Functional capacity was measured by the six-minute walk test and inspiratory muscle strength assessed by manovacuometry before and after the exercise protocols. Results Both groups demonstrated an increase in six-minute walk test distance after the experimental procedure compared to baseline; however, only the intervention group had a significant increase (P=0.08 and P=0.001 for the control and intervention groups, respectively). Intergroup comparison revealed a greater increase in the intervention group compared to the control (P<0.001). Regarding the inspiratory muscle strength evaluation, the intragroup analysis demonstrated increased strength after the protocols compared to baseline for both groups; statistical significance was only demonstrated for the intervention group, though (P=0.22 and P<0.01, respectively). Intergroup comparison showed a significant increase in the intervention group compared to the control (P<0.01). Conclusion Stationary cycle ergometer exercise training shows positive results on exercise capacity and inspiratory muscle strength in patients with heart failure awaiting cardiac transplantation while on intravenous inotropic support. PMID:27982348
An affordable method to obtain cultured endothelial cells from peripheral blood
Bueno-Betí, Carlos; Novella, Susana; Lázaro-Franco, Macarena; Pérez-Cremades, Daniel; Heras, Magda; Sanchís, Juan; Hermenegildo, Carlos
2013-01-01
The culture of endothelial progenitor cells (EPC) provides an excellent tool to research on EPC biology and vascular regeneration and vasculogenesis. The use of different protocols to obtain EPC cultures makes it difficult to obtain comparable results in different groups. This work offers a systematic comparison of the main variables of most commonly used protocols for EPC isolation, culture and functional evaluation. Peripheral blood samples from healthy individuals were recovered and mononuclear cells were cultured. Different recovery and culture conditions were tested: blood volume, blood anticoagulant, coating matrix and percentage of foetal bovine serum (FBS) in culture media. The success of culture procedure, first colonies of endothelial cells appearance time, correlation with number of circulating EPC (cEPC) and functional comparison with human umbilical vein endothelial cells (HUVEC) were studied. The use of heparin, a minimum blood volume of 30 ml, fibronectin as a coating matrix and endothelial growing media-2 supplemented with 20% FBS increased the success of obtaining EPC cultures up to 80% of the processed samples while reducing EPC colony appearance mean time to a minimum of 13 days. Blood samples exhibiting higher cEPC numbers resulted in reduced EPC colony appearance mean time. Cells isolated by using this combination were endothelial cell-like EPCs morphological and phenotypically. Functionally, cultured EPC showed decreased growing and vasculogenic capacity when compared to HUVEC. Thus, above-mentioned conditions allow the isolation and culture of EPC with smaller blood volumes and shorter times than currently used protocols. PMID:24118735
Röösli, Martin; Frei, Patrizia; Bolte, John; Neubauer, Georg; Cardis, Elisabeth; Feychting, Maria; Gajsek, Peter; Heinrich, Sabine; Joseph, Wout; Mann, Simon; Martens, Luc; Mohler, Evelyn; Parslow, Roger C; Poulsen, Aslak Harbo; Radon, Katja; Schüz, Joachim; Thuroczy, György; Viel, Jean-François; Vrijheid, Martine
2010-05-20
The development of new wireless communication technologies that emit radio frequency electromagnetic fields (RF-EMF) is ongoing, but little is known about the RF-EMF exposure distribution in the general population. Previous attempts to measure personal exposure to RF-EMF have used different measurement protocols and analysis methods making comparisons between exposure situations across different study populations very difficult. As a result, observed differences in exposure levels between study populations may not reflect real exposure differences but may be in part, or wholly due to methodological differences. The aim of this paper is to develop a study protocol for future personal RF-EMF exposure studies based on experience drawn from previous research. Using the current knowledge base, we propose procedures for the measurement of personal exposure to RF-EMF, data collection, data management and analysis, and methods for the selection and instruction of study participants. We have identified two basic types of personal RF-EMF measurement studies: population surveys and microenvironmental measurements. In the case of a population survey, the unit of observation is the individual and a randomly selected representative sample of the population is needed to obtain reliable results. For microenvironmental measurements, study participants are selected in order to represent typical behaviours in different microenvironments. These two study types require different methods and procedures. Applying our proposed common core procedures in future personal measurement studies will allow direct comparisons of personal RF-EMF exposures in different populations and study areas.
2010-01-01
Background The development of new wireless communication technologies that emit radio frequency electromagnetic fields (RF-EMF) is ongoing, but little is known about the RF-EMF exposure distribution in the general population. Previous attempts to measure personal exposure to RF-EMF have used different measurement protocols and analysis methods making comparisons between exposure situations across different study populations very difficult. As a result, observed differences in exposure levels between study populations may not reflect real exposure differences but may be in part, or wholly due to methodological differences. Methods The aim of this paper is to develop a study protocol for future personal RF-EMF exposure studies based on experience drawn from previous research. Using the current knowledge base, we propose procedures for the measurement of personal exposure to RF-EMF, data collection, data management and analysis, and methods for the selection and instruction of study participants. Results We have identified two basic types of personal RF-EMF measurement studies: population surveys and microenvironmental measurements. In the case of a population survey, the unit of observation is the individual and a randomly selected representative sample of the population is needed to obtain reliable results. For microenvironmental measurements, study participants are selected in order to represent typical behaviours in different microenvironments. These two study types require different methods and procedures. Conclusion Applying our proposed common core procedures in future personal measurement studies will allow direct comparisons of personal RF-EMF exposures in different populations and study areas. PMID:20487532
Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang
2018-02-01
The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.
A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas
NASA Astrophysics Data System (ADS)
Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.
2007-03-01
Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.
NASA Astrophysics Data System (ADS)
Shi, Jin; Claussen, Jonathan C.; McLamore, Eric S.; Haque, Aeraj ul; Jaroch, David; Diggs, Alfred R.; Calvo-Marzal, Percy; Rickus, Jenna L.; Porterfield, D. Marshall
2011-09-01
This work addresses the comparison of different strategies for improving biosensor performance using nanomaterials. Glucose biosensors based on commonly applied enzyme immobilization approaches, including sol-gel encapsulation approaches and glutaraldehyde cross-linking strategies, were studied in the presence and absence of multi-walled carbon nanotubes (MWNTs). Although direct comparison of design parameters such as linear range and sensitivity is intuitive, this comparison alone is not an accurate indicator of biosensor efficacy, due to the wide range of electrodes and nanomaterials available for use in current biosensor designs. We proposed a comparative protocol which considers both the active area available for transduction following nanomaterial deposition and the sensitivity. Based on the protocol, when no nanomaterials were involved, TEOS/GOx biosensors exhibited the highest efficacy, followed by BSA/GA/GOx and TMOS/GOx biosensors. A novel biosensor containing carboxylated MWNTs modified with glucose oxidase and an overlying TMOS layer demonstrated optimum efficacy in terms of enhanced current density (18.3 ± 0.5 µA mM - 1 cm - 2), linear range (0.0037-12 mM), detection limit (3.7 µM), coefficient of variation (2%), response time (less than 8 s), and stability/selectivity/reproducibility. H2O2 response tests demonstrated that the most possible reason for the performance enhancement was an increased enzyme loading. This design is an excellent platform for versatile biosensing applications.
Mayer, Kerstin; Wyckoff, Sarah Nicole; Fallgatter, Andreas J; Ehlis, Ann-Christine; Strehl, Ute
2015-04-18
Neurofeedback has been applied effectively in various areas, especially in the treatment of children with attention-deficit/hyperactivity disorder (ADHD). This study protocol is designed to investigate the effect of slow cortical potential (SCP) feedback and a new form of neurofeedback using near-infrared spectroscopy (NIRS) on symptomatology and neurophysiological parameters in an adult ADHD population. A comparison of SCP and NIRS feedback therapy methods has not been previously conducted and may yield valuable findings about alternative treatments for adult ADHD. The outcome of both neurofeedback techniques will be assessed over 30 treatment sessions and after a 6-month follow-up period, and then will be compared to a nonspecific biofeedback treatment. Furthermore, to investigate if treatment effects in this proof-of-principle study can be predicted by specific neurophysiological baseline parameters, regression models will be applied. Finally, a comparison with healthy controls will be conducted to evaluate deviant pretraining neurophysiological parameters, stability of assessment measures, and treatment outcome. To date, an investigation and comparison of SCP and NIRS feedback training to an active control has not been conducted; therefore, we hope to gain valuable insights in effects and differences of these types of treatment for ADHD in adults. This study is registered with the German Registry of Clinical Trials: DRKS00006767 , date of registration: 8 October 2014.
Saccharin Aza Bioisosteres-Synthesis and Preclinical Property Comparisons.
Chen, Yantao; Aurell, Carl-Johan; Pettersen, Anna; Lewis, Richard J; Hayes, Martin A; Lepistö, Matti; Jonson, Anna C; Leek, Hanna; Thunberg, Linda
2017-06-08
Saccharin is a well-known scaffold in drug discovery. Herein, we report the synthesis and preclinical property comparisons of three bioisosteres of saccharin: aza-pseudosaccharins (cluster B ), and two new types of aza-saccharins (clusters C and D ). We demonstrate a convenient protocol to selectively synthesize products in cluster C or D when primary amines are used. Preclinical characterization of selected matched-pair products is reported. Through comparison of two diastereomers, we highlight how stereochemistry affects the preclinical properties. Given that saccharin-based derivatives are widely used in many chemistry fields, we foresee that structures exemplified by clusters C and D offer new opportunities for novel drug design, creating a chiral center on the sulfur atom and the option of substitution at two different nitrogens.
Panelli, Simona; Damiani, Giuseppe; Espen, Luca; Micheli, Gioacchino; Sgaramella, Vittorio
2006-05-10
The development of methods for the analysis and comparison of the nucleic acids contained in single cells is an ambitious and challenging goal that may provide useful insights in many physiopathological processes. We review here some of the published protocols for the amplification of whole genomes (WGA). We focus on the reaction known as Multiple Displacement Amplification (MDA), which probably represents the most reliable and efficient WGA protocol developed to date. We discuss some recent advances and applications, as well as some modifications to the reaction, which should improve its use and enlarge its range of applicability possibly to degraded genomes, and also to RNA via complementary DNA.
Zhang, P; Aungskunsiri, K; Martín-López, E; Wabnig, J; Lobino, M; Nock, R W; Munns, J; Bonneau, D; Jiang, P; Li, H W; Laing, A; Rarity, J G; Niskanen, A O; Thompson, M G; O'Brien, J L
2014-04-04
We demonstrate a client-server quantum key distribution (QKD) scheme. Large resources such as laser and detectors are situated at the server side, which is accessible via telecom fiber to a client requiring only an on-chip polarization rotator, which may be integrated into a handheld device. The detrimental effects of unstable fiber birefringence are overcome by employing the reference-frame-independent QKD protocol for polarization qubits in polarization maintaining fiber, where standard QKD protocols fail, as we show for comparison. This opens the way for quantum enhanced secure communications between companies and members of the general public equipped with handheld mobile devices, via telecom-fiber tethering.
Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F
2012-09-07
We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.
NASA Astrophysics Data System (ADS)
Jacak, Monika; Jacak, Janusz; Jóźwiak, Piotr; Jóźwiak, Ireneusz
2016-06-01
The overview of the current status of quantum cryptography is given in regard to quantum key distribution (QKD) protocols, implemented both on nonentangled and entangled flying qubits. Two commercial R&D platforms of QKD systems are described (the Clavis II platform by idQuantique implemented on nonentangled photons and the EPR S405 Quelle platform by AIT based on entangled photons) and tested for feasibility of their usage in commercial TELECOM fiber metropolitan networks. The comparison of systems efficiency, stability and resistivity against noise and hacker attacks is given with some suggestion toward system improvement, along with assessment of two models of QKD.
Benton, Katie; Thomson, Iain; Isenring, Elisabeth; Mark Smithers, B; Agarwal, Ekta
2018-06-01
Enhanced Recovery After Surgery (ERAS) protocols have been effectively expanded to various surgical specialities including oesophagectomy. Despite nutrition being a key component, actual nutrition outcomes and specific guidelines are lacking. This cohort comparison study aims to compare nutritional status and adherence during implementation of a standardised post-operative nutritional support protocol, as part of ERAS, compared to those who received usual care. Two groups of patients undergoing resection of oesophageal cancer were studied. Group 1 (n = 17) underwent oesophagectomy between Oct 2014 and Nov 2016 during implementation of an ERAS protocol. Patients in group 2 (n = 16) underwent oesophagectomy between Jan 2011 and Dec 2012 prior to the implementation of ERAS. Demographic, nutritional status, dietary intake and adherence data were collected. Ordinal data was analysed using independent t tests, and categorical data using chi-square tests. There was no significant difference in nutrition status, dietary intake or length of stay following implementation of an ERAS protocol. Malnutrition remained prevalent in both groups at day 42 post surgery (n = 10, 83% usual care; and n = 9, 60% ERAS). A significant difference was demonstrated in adherence with earlier initiation of oral free fluids (p <0.008), transition to soft diet (p <0.004) and continuation of jejunostomy feeds on discharge (p <0.000) for the ERAS group. A standardised post-operative nutrition protocol, within an ERAS framework, results in earlier transition to oral intake; however, malnutrition remains prevalent post surgery. Further large-scale studies are warranted to examine individualised decision-making regarding nutrition support within an ERAS protocol.
Beus, Christopher; Safavi, Kamran; Stratton, Jeffrey; Kaufman, Blythe
2012-11-01
The purpose of this prospective, randomized clinical study was to compare the results of a nonactivated single-irrigation protocol (NAI) that used only 1% NaOCl with a passive ultrasonic multi-irrigation protocol (PUI) that used 1% NaOCl, 17% ethylenediaminetetraacetic acid, and 2% chlorhexidine in rendering canals bacteria free. In addition, the effect of a second-visit instrumentation after intra-appointment calcium hydroxide (CaOH(2)) was also evaluated in bacterial elimination. Fifty patients were recruited with a posterior tooth requiring primary endodontic treatment of apical periodontitis. Standard nonsurgical endodontic therapy was performed on both groups in a 2-visit approach by using calcium hydroxide intracanal medicament. Teeth were randomly treated with the NAI or PUI protocols in the first visit after complete instrumentation. Bacterial cultures were obtained at 4 periods during treatment from the canals: (1) before instrumentation, (2) after irrigation protocol, (3) after CaOH(2) medication, and (4) before obturation. Statistical analysis was performed on data by using the Fisher exact test and multivariate analysis. NAI and PUI rendered canals 80% and 84% bacteria free, respectively, at the end of the first visit. After CaOH(2) medication the total sample (NAI + PUI) had increased to 87% bacteria free, and the second-visit instrumentation resulted in a total of 91% bacteria free. These differences were not significant (P > .05). There was no statistical difference between irrigation methods. Each protocol resulted in a high frequency of negative cultures. This high frequency of negative cultures obtained in 1 visit is most likely related to an increased volume and depth of irrigation compared with previously reported protocols. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Williams, N; Coburn, J; Gillum, T
2015-11-01
The aim of this paper was to determine if two different warm-up protocols differently affect torque of the quadriceps and hamstrings, and electromyography (EMG) output of the rectus femoris (RF) and vastus lateralis (VL) when completing 30 maximal leg extensions and curls. Twenty-one healthy male (N.=8) and female (N.=13) subjects volunteered to participate in a familiarization session and three testing sessions. The three testing sessions control, dynamic, and static were completed in a counterbalanced order on non-consecutive days. First, subjects warmed-up on a treadmill for five minutes before completing six dynamic movements, six static-stretches, or no stretches. They then rested for five minutes before completing 30 maximal leg extensions and curls at a speed of 60 s-1. A significant decrease in quadriceps torque output over time was determined for the dynamic protocol when compared to the control (P<0.01) and static (P<0.05) protocols. A significant decrease was found in peak quadriceps torque for the dynamic protocol (P<0.01) when compared to the static, and a significant increase was found for the static protocol (P<0.05) when compared to the control. A significant decrease in average quadriceps torque was found for the dynamic protocol when compared to the static (P<0.05) and control (P<0.01) protocols. No difference was found in hamstring torque or EMG output of the RF and VL. Short duration static-stretching has the ability to increase peak and average torque of the leg extensors, while some types of anaerobic exercise involving maximal contractions to fatigue may be hindered by performing dynamic movements as part of the warm-up.
Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A
2014-03-01
Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.
Bischel, Alexander; Stratis, Andreas; Kakar, Apoorv; Bosmans, Hilde; Jacobs, Reinhilde; Gassner, Eva-Maria; Puelacher, Wolfgang; Pauwels, Ruben
2016-01-01
Objective: The aim of this study was to evaluate whether application of ultralow dose protocols and iterative reconstruction technology (IRT) influence quantitative Hounsfield units (HUs) and contrast-to-noise ratio (CNR) in dentomaxillofacial CT imaging. Methods: A phantom with inserts of five types of materials was scanned using protocols for (a) a clinical reference for navigated surgery (CT dose index volume 36.58 mGy), (b) low-dose sinus imaging (18.28 mGy) and (c) four ultralow dose imaging (4.14, 2.63, 0.99 and 0.53 mGy). All images were reconstructed using: (i) filtered back projection (FBP); (ii) IRT: adaptive statistical iterative reconstruction-50 (ASIR-50), ASIR-100 and model-based iterative reconstruction (MBIR); and (iii) standard (std) and bone kernel. Mean HU, CNR and average HU error after recalibration were determined. Each combination of protocols was compared using Friedman analysis of variance, followed by Dunn's multiple comparison test. Results: Pearson's sample correlation coefficients were all >0.99. Ultralow dose protocols using FBP showed errors of up to 273 HU. Std kernels had less HU variability than bone kernels. MBIR reduced the error value for the lowest dose protocol to 138 HU and retained the highest relative CNR. ASIR could not demonstrate significant advantages over FBP. Conclusions: Considering a potential dose reduction as low as 1.5% of a std protocol, ultralow dose protocols and IRT should be further tested for clinical dentomaxillofacial CT imaging. Advances in knowledge: HU as a surrogate for bone density may vary significantly in CT ultralow dose imaging. However, use of std kernels and MBIR technology reduce HU error values and may retain the highest CNR. PMID:26859336
Boza, Aysen; Cakar, Erbil; Boza, Barıs; Api, Murat; Kayatas, Semra; Sofuoglu, Kenan
2016-01-01
Background: Microdose flare-up GnRH agonist and GnRH antagonist have become more popular in the management of poor ovarian responders (POR) in recent years; however, the optimal protocol for POR patients undergoing in vitro fertilization has still been a challenge. Methods: In this observational study design, two hundred forty four poor ovarian responders were retrospectively evaluated for their response to GnRH agonist protocol (group-1, n=135) or GnRH antagonist protocol (group-2, n=109). Clinical pregnancy rate was the primary end point and was compared between the groups. Student t-test, Mann Whitney U test and χ2-test were used to compare the groups. The p<0.05 was considered to show a statistically significant result. Results: The mean total gonadotropin doses were 3814±891 IU in group 1 and 3539±877 IU in group 2 (p=0.02). The number of metaphase-II oocytes (3.6±2.4 vs. 2.8±1.9, p=0.005) and implantation rates (27.8% vs. 18.8%, p=0.04) in group 1 and group 2, respectively were significantly different. The fertilization rate in group 1 and group 2 was 73% vs. 68%, respectively (p=0.5) and clinical pregnancy rate was 19.8% vs. 14.4%, respectively (p=0.13). Conclusion: The GnRH agonist microdose flare-up protocol has favorable outcomes with respect to the number of oocytes retrieved and implantation rate; nevertheless, the clinical pregnancy rate was found to be similar in comparison to GnRH antagonist protocol in poor ovarian responders. GnRH antagonist protocol appears to be promising with significantly lower gonadotropin requirement and lower treatment cost in poor ovarian responders. PMID:27478770
Boza, Aysen; Cakar, Erbil; Boza, Barıs; Api, Murat; Kayatas, Semra; Sofuoglu, Kenan
2016-01-01
Microdose flare-up GnRH agonist and GnRH antagonist have become more popular in the management of poor ovarian responders (POR) in recent years; however, the optimal protocol for POR patients undergoing in vitro fertilization has still been a challenge. In this observational study design, two hundred forty four poor ovarian responders were retrospectively evaluated for their response to GnRH agonist protocol (group-1, n=135) or GnRH antagonist protocol (group-2, n=109). Clinical pregnancy rate was the primary end point and was compared between the groups. Student t-test, Mann Whitney U test and χ (2)-test were used to compare the groups. The p<0.05 was considered to show a statistically significant result. The mean total gonadotropin doses were 3814±891 IU in group 1 and 3539±877 IU in group 2 (p=0.02). The number of metaphase-II oocytes (3.6±2.4 vs. 2.8±1.9, p=0.005) and implantation rates (27.8% vs. 18.8%, p=0.04) in group 1 and group 2, respectively were significantly different. The fertilization rate in group 1 and group 2 was 73% vs. 68%, respectively (p=0.5) and clinical pregnancy rate was 19.8% vs. 14.4%, respectively (p=0.13). The GnRH agonist microdose flare-up protocol has favorable outcomes with respect to the number of oocytes retrieved and implantation rate; nevertheless, the clinical pregnancy rate was found to be similar in comparison to GnRH antagonist protocol in poor ovarian responders. GnRH antagonist protocol appears to be promising with significantly lower gonadotropin requirement and lower treatment cost in poor ovarian responders.
de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A
2018-05-01
This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.
Mellors, L J; Gibbs, C L; Barclay, C J
2001-05-01
The results of previous studies suggest that the maximum mechanical efficiency of rat papillary muscles is lower during a contraction protocol involving sinusoidal length changes than during one involving afterloaded isotonic contractions. The aim of this study was to compare directly the efficiency of isolated rat papillary muscle preparations in isotonic and sinusoidal contraction protocols. Experiments were performed in vitro (27 degrees C) using left ventricular papillary muscles from adult rats. Each preparation performed three contraction protocols: (i) low-frequency afterloaded isotonic contractions (10 twitches at 0.2 Hz), (ii) sinusoidal length change contractions with phasic stimulation (40 twitches at 2 Hz) and (iii) high-frequency afterloaded isotonic contractions (40 twitches at 2 Hz). The first two protocols resembled those used in previous studies and the third combined the characteristics of the first two. The parameters for each protocol were adjusted to those that gave maximum efficiency. For the afterloaded isotonic protocols, the afterload was set to 0.3 of the maximum developed force. The sinusoidal length change protocol incorporated a cycle amplitude of +/-5% resting length and a stimulus phase of -10 degrees. Measurements of force output, muscle length change and muscle temperature change were used to calculate the work and heat produced during and after each protocol. Net mechanical efficiency was defined as the proportion of the energy (enthalpy) liberated by the muscle that appeared as work. The efficiency in the low-frequency, isotonic contraction protocol was 21.1+/-1.4% (mean +/- s.e.m., N=6) and that in the sinusoidal protocol was 13.2+/-0.7%, consistent with previous results. This difference was not due to the higher frequency or greater number of twitches because efficiency in the high-frequency, isotonic protocol was 21.5+/-1.0%. Although these results apparently confirm that efficiency is protocol-dependent, additional experiments designed to measure work output unambiguously indicated that the method used to calculate work output in isotonic contractions overestimated actual work output. When net work output, which excludes work done by parallel elastic elements, rather than total work output was used to determine efficiency in afterloaded isotonic contractions, efficiency was similar to that for sinusoidal contractions. The maximum net mechanical efficiency of rat papillary muscles performing afterloaded isotonic or sinusoidal length change contractions was between 10 and 15%.
Self-adaptive trust based ABR protocol for MANETs using Q-learning.
Kumar, Anitha Vijaya; Jeyapal, Akilandeswari
2014-01-01
Mobile ad hoc networks (MANETs) are a collection of mobile nodes with a dynamic topology. MANETs work under scalable conditions for many applications and pose different security challenges. Due to the nomadic nature of nodes, detecting misbehaviour is a complex problem. Nodes also share routing information among the neighbours in order to find the route to the destination. This requires nodes to trust each other. Thus we can state that trust is a key concept in secure routing mechanisms. A number of cryptographic protection techniques based on trust have been proposed. Q-learning is a recently used technique, to achieve adaptive trust in MANETs. In comparison to other machine learning computational intelligence techniques, Q-learning achieves optimal results. Our work focuses on computing a score using Q-learning to weigh the trust of a particular node over associativity based routing (ABR) protocol. Thus secure and stable route is calculated as a weighted average of the trust value of the nodes in the route and associativity ticks ensure the stability of the route. Simulation results show that Q-learning based trust ABR protocol improves packet delivery ratio by 27% and reduces the route selection time by 40% over ABR protocol without trust calculation.
Self-Adaptive Trust Based ABR Protocol for MANETs Using Q-Learning
Jeyapal, Akilandeswari
2014-01-01
Mobile ad hoc networks (MANETs) are a collection of mobile nodes with a dynamic topology. MANETs work under scalable conditions for many applications and pose different security challenges. Due to the nomadic nature of nodes, detecting misbehaviour is a complex problem. Nodes also share routing information among the neighbours in order to find the route to the destination. This requires nodes to trust each other. Thus we can state that trust is a key concept in secure routing mechanisms. A number of cryptographic protection techniques based on trust have been proposed. Q-learning is a recently used technique, to achieve adaptive trust in MANETs. In comparison to other machine learning computational intelligence techniques, Q-learning achieves optimal results. Our work focuses on computing a score using Q-learning to weigh the trust of a particular node over associativity based routing (ABR) protocol. Thus secure and stable route is calculated as a weighted average of the trust value of the nodes in the route and associativity ticks ensure the stability of the route. Simulation results show that Q-learning based trust ABR protocol improves packet delivery ratio by 27% and reduces the route selection time by 40% over ABR protocol without trust calculation. PMID:25254243
Eustachian tube function in adults without middle ear disease.
Swarts, J Douglas; Alper, Cuneyt M; Mandel, Ellen M; Villardo, Richard; Doyle, William J
2011-04-01
We sought to develop normative values for 5 eustachian tube function (ETF) test protocols in adults without otitis media (OM). Twenty adults (19 to 48 years of age) without a recent history of OM (5 had OM in childhood) underwent unilateral myringotomy and were evaluated for ETF by use of the forced response, inflation, deflation, forcible "sniff", and Valsalva test protocols. When possible, these tests were repeated on a second day. Normative values for the parameters of these protocols in adult subjects without a recent history of OM were developed. Between-day data for the forced response test were highly correlated. A percentage of these tests showed eustachian tube "constriction" during swallowing--an abnormal condition. The percent reduction in applied pressures for the inflation and deflation tests was high, indicative of good ETF. Few subjects had a positive "sniff" test, whereas most had a positive Valsalva test, and the results for both tests were effort-dependent. Results of ETF tests in adults with and without recent OM have not been published. Normative data are now available for comparison with ETF test results in adults with OM. These protocols will be used to evaluate the efficacy of surgical procedures designed to improve ETF.
Rozenberg, Andrey; Leese, Florian; Weiss, Linda C; Tollrian, Ralph
2016-01-01
Tag-Seq is a high-throughput approach used for discovering SNPs and characterizing gene expression. In comparison to RNA-Seq, Tag-Seq eases data processing and allows detection of rare mRNA species using only one tag per transcript molecule. However, reduced library complexity raises the issue of PCR duplicates, which distort gene expression levels. Here we present a novel Tag-Seq protocol that uses the least biased methods for RNA library preparation combined with a novel approach for joint PCR template and sample labeling. In our protocol, input RNA is fragmented by hydrolysis, and poly(A)-bearing RNAs are selected and directly ligated to mixed DNA-RNA P5 adapters. The P5 adapters contain i5 barcodes composed of sample-specific (moderately) degenerate base regions (mDBRs), which later allow detection of PCR duplicates. The P7 adapter is attached via reverse transcription with individual i7 barcodes added during the amplification step. The resulting libraries can be sequenced on an Illumina sequencer. After sample demultiplexing and PCR duplicate removal with a free software tool we designed, the data are ready for downstream analysis. Our protocol was tested on RNA samples from predator-induced and control Daphnia microcrustaceans.
Dissociation of learned helplessness and fear conditioning in mice: a mouse model of depression.
Landgraf, Dominic; Long, Jaimie; Der-Avakian, Andre; Streets, Margo; Welsh, David K
2015-01-01
The state of being helpless is regarded as a central aspect of depression, and therefore the learned helplessness paradigm in rodents is commonly used as an animal model of depression. The term 'learned helplessness' refers to a deficit in escaping from an aversive situation after an animal is exposed to uncontrollable stress specifically, with a control/comparison group having been exposed to an equivalent amount of controllable stress. A key feature of learned helplessness is the transferability of helplessness to different situations, a phenomenon called 'trans-situationality'. However, most studies in mice use learned helplessness protocols in which training and testing occur in the same environment and with the same type of stressor. Consequently, failures to escape may reflect conditioned fear of a particular environment, not a general change of the helpless state of an animal. For mice, there is no established learned helplessness protocol that includes the trans-situationality feature. Here we describe a simple and reliable learned helplessness protocol for mice, in which training and testing are carried out in different environments and with different types of stressors. We show that with our protocol approximately 50% of mice develop learned helplessness that is not attributable to fear conditioning.
Atmospheric Correction Inter-comparison Exercise (ACIX)
NASA Astrophysics Data System (ADS)
Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.
2017-12-01
The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison outcomes were presented and discussed among the ACIX participants in the 2nd ACIX workshop, which was held on 11-12 April 2017 (ESRIN/ESA) and a detailed report was compiled. The proposed presentation is an opportunity for the user community to be informed about the ACIX results and conclusions.
Guidelines for randomized clinical trial protocol content: a systematic review
2012-01-01
Background All randomized clinical trials (RCTs) require a protocol; however, numerous studies have highlighted protocol deficiencies. Reporting guidelines may improve the content of research reports and, if developed using robust methods, may increase the utility of reports to stakeholders. The objective of this study was to systematically identify and review RCT protocol guidelines, to assess their characteristics and methods of development, and to compare recommendations. Methods We conducted a systematic review of indexed literature (MEDLINE, EMBASE and the Cochrane Methodology Register from inception to September 2010; reference lists; related article features; forward citation searching) and a targeted search of supplementary sources, including a survey of major trial funding agencies in six countries. Records were eligible if they described a content guideline in English or French relevant to RCT protocols. Guidelines were excluded if they specified content for protocols for trials of specific procedures or conditions or were intended to assess trial quality. We extracted guideline characteristics and methods. Content was mapped for a subset of guidelines that described development methods or had institutional endorsement. Results Forty guidelines published in journals, books and institutional reports were included in the review; seven were specific to RCT protocols. Only eight (20%) described development methods which included informal consensus methods, pilot testing and formal validation; no guideline described all of these methods. No guideline described formal consensus methods or a systematic retrieval of empirical evidence to inform its development. The guidelines included a median of 23 concepts per guideline (interquartile range (IQR) = 14 to 34; range = 7 to 109). Among the subset of guidelines (n = 23) for which content was mapped, approximately 380 concepts were explicitly addressed (median concepts per guideline IQR = 31 (24,80); range = 16 to 150); most concepts were addressed in a minority of guidelines. Conclusions Existing guidelines for RCT protocol content varied substantially in their recommendations. Few reports described the methods of guideline development, limiting comparisons of guideline validity. Given the importance of protocols to diverse stakeholders, we believe a systematically developed, evidence-informed guideline for clinical trial protocols is needed. PMID:23006870
Delefortrie, Quentin; Schatt, Patricia; Grimmelprez, Alexandre; Gohy, Patrick; Deltour, Didier; Collard, Geneviève; Vankerkhoven, Patrick
2016-02-01
Although colonoscopy associated with histopathological sampling remains the gold standard in the diagnostic and follow-up of inflammatory bowel disease (IBD), calprotectin is becoming an essential biomarker in gastroenterology. The aim of this work is to compare a newly developed kit (Liaison® Calprotectin - Diasorin®) and its two distinct extraction protocols (weighing and extraction device protocol) with a well established point of care test (Quantum Blue® - Bühlmann-Alere®) in terms of analytical performances and ability to detect relapses amongst a Crohn's population in follow-up. Stool specimens were collected over a six month period and were composed of control and Crohn's patients. Amongst the Crohn's population disease activity (active vs quiescent) was evaluated by gastroenterologists. A significant difference was found between all three procedures in terms of calprotectin measurements (weighing protocol=30.3μg/g (median); stool extraction device protocol=36.9μg/g (median); Quantum Blue® (median)=63; Friedman test, P value=0.05). However, a good correlation was found between both extraction methods coupled with the Liaison® analyzer and between the Quantum Blue® (weighing protocol/extraction device protocol Rs=0.844, P=0.01; Quantum Blue®/extraction device protocol Rs=0.708, P=0.01; Quantum Blue®/weighing protocol, Rs=0.808, P=0.01). Finally, optimal cut-offs (and associated negative predictive values - NPV) for detecting relapses were in accordance with above results (Quantum Blue® 183.5μg/g and NPV of 100%>extraction device protocol+Liaison® analyzer 124.5μg/g and NPV of 93.5%>weighing protocol+Liaison® analyzer 106.5μg/g and NPV of 95%). Although all three methods correlated well and had relatively good NPV in terms of detecting relapses amongst a Crohn's population in follow-up, the lack of any international standard is the origin of different optimal cut-offs between the three procedures. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Guidelines for randomized clinical trial protocol content: a systematic review.
Tetzlaff, Jennifer M; Chan, An-Wen; Kitchen, Jessica; Sampson, Margaret; Tricco, Andrea C; Moher, David
2012-09-24
All randomized clinical trials (RCTs) require a protocol; however, numerous studies have highlighted protocol deficiencies. Reporting guidelines may improve the content of research reports and, if developed using robust methods, may increase the utility of reports to stakeholders. The objective of this study was to systematically identify and review RCT protocol guidelines, to assess their characteristics and methods of development, and to compare recommendations. We conducted a systematic review of indexed literature (MEDLINE, EMBASE and the Cochrane Methodology Register from inception to September 2010; reference lists; related article features; forward citation searching) and a targeted search of supplementary sources, including a survey of major trial funding agencies in six countries. Records were eligible if they described a content guideline in English or French relevant to RCT protocols. Guidelines were excluded if they specified content for protocols for trials of specific procedures or conditions or were intended to assess trial quality. We extracted guideline characteristics and methods. Content was mapped for a subset of guidelines that described development methods or had institutional endorsement. Forty guidelines published in journals, books and institutional reports were included in the review; seven were specific to RCT protocols. Only eight (20%) described development methods which included informal consensus methods, pilot testing and formal validation; no guideline described all of these methods. No guideline described formal consensus methods or a systematic retrieval of empirical evidence to inform its development. The guidelines included a median of 23 concepts per guideline (interquartile range (IQR) = 14 to 34; range = 7 to 109). Among the subset of guidelines (n = 23) for which content was mapped, approximately 380 concepts were explicitly addressed (median concepts per guideline IQR = 31 (24,80); range = 16 to 150); most concepts were addressed in a minority of guidelines. Existing guidelines for RCT protocol content varied substantially in their recommendations. Few reports described the methods of guideline development, limiting comparisons of guideline validity. Given the importance of protocols to diverse stakeholders, we believe a systematically developed, evidence-informed guideline for clinical trial protocols is needed.
Kollara, Lakshmi; Schenck, Graham; Jaskolka, Michael; Perry, Jamie L
2017-04-14
To date, no studies have imaged the velopharynx in children with 22q11.2 deletion syndrome (22q11.2 DS) without the use of sedation. Dysmorphology in velopharyngeal structures has been shown to have significant negative implications on speech among these individuals. This single case study was designed to assess the feasibility of a child-friendly magnetic resonance imaging (MRI) scanning protocol in this clinically challenging population and to determine the utility of this MRI protocol for future work in this area. One 6-year-old White girl diagnosed with 22q11.2 DS was imaged using a child-friendly, nonsedated MRI protocol. Quantitative and qualitative measures of the velopharyngeal area and associated structures were evaluated, and comparisons were made to age-matched control subjects with normal velopharyngeal anatomy. MRI data were successfully obtained using the child-friendly scanning protocol in the subject in the present study. Quantitative and qualitative differences of the levator muscle and associated velopharyngeal structures were noted. Using these MRI and structural analyses methods, insights related to muscle morphology can be obtained and considered as part of the research and clinical examination of children with 22q11.2 DS. The imaging protocol described in this study presents an effective means to counteract difficulties in imaging young children.
Rahman, Shafiq; Griffin, Michelle; Naik, Anish; Szarko, Matthew; Butler, Peter E M
2018-02-15
Decellularized scaffolds can induce chondrogenic differentiation of stem cells. This study compares different methods to optimise the decellularization of auricular cartilage. The process consisted of an initial 12 hour dry freeze thaw which froze the cartilage specimens in an empty tube at -20 °C. Samples were allowed to thaw at room temperature followed by submersion in phosphate buffer solution in which they were frozen at -20 °C for a 12 hour period. They were then allowed to thaw at room temperature as before. Protocol A subsequently involved subjecting specimens to both deoxyribonuclease and sodium deoxycholate. Protocol B and C were adaptations of this using 0.25% trypsin (7 cycles) and a 0.5 molar solution of ethylenediaminetetraacetic acid (3 hours for each cycle) respectively as additional steps. Trypsin accelerated the decellularization process with a reduction in DNA content from 55.4 ng/μL (native) to 17.3 ng/μL (P-value < 0.05) after 14 days. Protocol B showed a faster reduction in DNA content when compared with protocol A. In comparison to protocol C after 14 days, trypsin also showed greater decellularization with a mean difference of 11.7 ng/μL (P-value < 0.05). Histological analysis with H&E and DAPI confirmed depletion of cells at 14 days with trypsin.
Chian, Teo Chee; Nassir, Norziana Mat; Ibrahim, Mohd Izuan; Yusof, Ahmad Khairuddin Md; Sabarudin, Akmal
2017-02-01
This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols. Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software. Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp. There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.
Iskandar, Michèle M.; Lands, Larry C.; Sabally, Kebba; Azadi, Behnam; Meehan, Brian; Mawji, Nadir; Skinner, Cameron D.; Kubow, Stan
2015-01-01
Whey proteins have well-established antioxidant and anti-inflammatory bioactivities. High hydrostatic pressure processing of whey protein isolates increases their in vitro digestibility resulting in enhanced antioxidant and anti-inflammatory effects. This study compared the effects of different digestion protocols on the digestibility of pressurized (pWPI) and native (nWPI) whey protein isolates and the antioxidant and anti-inflammatory properties of the hydrolysates. The pepsin-pancreatin digestion protocol was modified to better simulate human digestion by adjusting temperature and pH conditions, incubation times, enzymes utilized, enzyme-to-substrate ratio and ultrafiltration membrane molecular weight cut-off. pWPI showed a significantly greater proteolysis rate and rate of peptide appearance regardless of digestion protocol. Both digestion methods generated a greater relative abundance of eluting peptides and the appearance of new peptide peaks in association with pWPI digestion in comparison to nWPI hydrolysates. Hydrolysates of pWPI from both digestion conditions showed enhanced ferric-reducing antioxidant power relative to nWPI hydrolysates. Likewise, pWPI hydrolysates from both digestion protocols showed similar enhanced antioxidant and anti-inflammatory effects in a respiratory epithelial cell line as compared to nWPI hydrolysates. These findings indicate that regardless of considerable variations of in vitro digestion protocols, pressurization of WPI leads to more efficient digestion that improves its antioxidant and anti-inflammatory properties. PMID:28231198
Iskandar, Michèle M; Lands, Larry C; Sabally, Kebba; Azadi, Behnam; Meehan, Brian; Mawji, Nadir; Skinner, Cameron D; Kubow, Stan
2015-05-28
Whey proteins have well-established antioxidant and anti-inflammatory bioactivities. High hydrostatic pressure processing of whey protein isolates increases their in vitro digestibility resulting in enhanced antioxidant and anti-inflammatory effects. This study compared the effects of different digestion protocols on the digestibility of pressurized (pWPI) and native (nWPI) whey protein isolates and the antioxidant and anti-inflammatory properties of the hydrolysates. The pepsin-pancreatin digestion protocol was modified to better simulate human digestion by adjusting temperature and pH conditions, incubation times, enzymes utilized, enzyme-to-substrate ratio and ultrafiltration membrane molecular weight cut-off. pWPI showed a significantly greater proteolysis rate and rate of peptide appearance regardless of digestion protocol. Both digestion methods generated a greater relative abundance of eluting peptides and the appearance of new peptide peaks in association with pWPI digestion in comparison to nWPI hydrolysates. Hydrolysates of pWPI from both digestion conditions showed enhanced ferric-reducing antioxidant power relative to nWPI hydrolysates. Likewise, pWPI hydrolysates from both digestion protocols showed similar enhanced antioxidant and anti-inflammatory effects in a respiratory epithelial cell line as compared to nWPI hydrolysates. These findings indicate that regardless of considerable variations of in vitro digestion protocols, pressurization of WPI leads to more efficient digestion that improves its antioxidant and anti-inflammatory properties.
Hatchett, Andrew; Berry, Christopher; Oliva, Claudia; Wiley, Douglas; St. Hilaire, Jacob; LaRochelle, Alex
2016-01-01
This investigation sought to examine the effect that a chocolate milk solution (CMS) and a raw milk solution (RMS) had on lower extremity induced delayed onset of muscle soreness (DOMS). Twenty trained male participants completed a set of questionnaires, prior to completing a lower extremity DOMS protocol, to determine the level of discomfort and functional limitations. Once the DOMS protocol was completed, participants were randomly assigned to either the CM or RM group. Once assigned, participants ingested 240 mL of the respective solution and completed the same set of questionnaires immediately post, 24-, 48- and 72-h post DOMS protocol. Additionally, for 10 days post-ingestion participants were contacted to learn if any negative effects were experienced as a result of ingesting either solution. Both groups reported an increase in lower extremity discomfort at each data collection interval post-DOMS protocol (post, 24-, 48- and 72-h). Participants assigned to the RM group reported high discomfort post and a relative decline in discomfort from immediately post-DOMS protocol to 72-h post. The RMS group reported substantially less discomfort at 72-h when compared to the CMS group. Ingestion of a raw milk solution immediately post strength exercise can substantially reduce the level of self-reported discomfort associated with DOMS. PMID:29910267
Chang, Yuchao; Tang, Hongying; Cheng, Yongbo; Zhao, Qin; Yuan, Baoqing Li andXiaobing
2017-07-19
Routing protocols based on topology control are significantly important for improving network longevity in wireless sensor networks (WSNs). Traditionally, some WSN routing protocols distribute uneven network traffic load to sensor nodes, which is not optimal for improving network longevity. Differently to conventional WSN routing protocols, we propose a dynamic hierarchical protocol based on combinatorial optimization (DHCO) to balance energy consumption of sensor nodes and to improve WSN longevity. For each sensor node, the DHCO algorithm obtains the optimal route by establishing a feasible routing set instead of selecting the cluster head or the next hop node. The process of obtaining the optimal route can be formulated as a combinatorial optimization problem. Specifically, the DHCO algorithm is carried out by the following procedures. It employs a hierarchy-based connection mechanism to construct a hierarchical network structure in which each sensor node is assigned to a special hierarchical subset; it utilizes the combinatorial optimization theory to establish the feasible routing set for each sensor node, and takes advantage of the maximum-minimum criterion to obtain their optimal routes to the base station. Various results of simulation experiments show effectiveness and superiority of the DHCO algorithm in comparison with state-of-the-art WSN routing algorithms, including low-energy adaptive clustering hierarchy (LEACH), hybrid energy-efficient distributed clustering (HEED), genetic protocol-based self-organizing network clustering (GASONeC), and double cost function-based routing (DCFR) algorithms.
On-farm comparisons of different cleaning protocols in broiler houses.
Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K
2015-08-01
The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.
NASA Astrophysics Data System (ADS)
Iwase, Satoshi; Sugenoya, Junichi; Sato, Maki; Shimizu, Yuuki; Kanikowska, Dominika; Nishimura, Nooki; Takada, Hiroki; Takada, Masumi; Mano, Tadaki; Ishida, Koji; Akima, Hiroshi; Katayama, Keisho; Hirayanagi, Kaname; Shiozawa, Tomoki; Yajima, Katzuyoshi; Watanabe, Yoriko; Suzuki, Satomi; Fukunnaga, Tetsuo; Masuo, Yoshihisa
2008-06-01
Effectiveness of centrifuge-induced artificial gravity and ergometric exercise as a countermeasure to space deconditioning, including cardiovascular deconditioning, myatrophy, and osteoporosis, induced by 20 days of head-down bedrest., was examined in 12 healthy men in 2006, and 8 healthy men in 2007. Bedrest was performed with 2300 kcal of diet. Water intake was recommended more than the urine volume in a previous day. A new protocol for artificial gravity with ergometric exercise was adopted, with 1.6 G of artificial gravity at heart level and 60 W of exercise every day in 2006, and every other day in 2007. The load was suspended when subjects complained all-out, and was continued until 30 min cumulative total load time. Gravity was stepped up by 0.2 G or exercise load was stepped up by 15 W alternately when the subject endured the load for 5 min. Gravity tolerance was examined by using centrifuge, and anti-G score was determined before and after the bedrest. Not all result has been analyzed, however, effectiveness of artificial gravity with ergometric exercise was evidenced in orthostatic tolerance, physical fitness, cardiac function, myatrophy, and bone metabolism in everyday protocol, but not in every other day protocol. We concluded this everyday protocol was effective in cardiovascular deconditioning myatrophy, and bone metabolism.
Classification of pregnancies of unknown location according to four different hCG-based protocols.
Fistouris, J; Bergh, C; Strandell, A
2016-10-01
How do four protocols based on serial human chorionic gonadotropin (hCG) measurements perform when classifying pregnancies of unknown location (PULs) as low or high risk of being an ectopic pregnancy (EP)? The use of cut-offs in hCG level changes published by NICE, and a logistic regression model, M4, correctly classify more PULs as high risk, compared with two other protocols. A logistic regression model, M4, based on the mean of two consecutive hCG values and the hCG ratio (hCG 48 h/hCG 0 h) that classify PULs into low- and high-risk groups for triage purposes, identifies more EPs than a protocol using the cut-offs between a 13% decline and a 66% rise in hCG levels over 48 h. A retrospective comparative study of four different hCG-based protocols classifying PULs as low or high risk of being an EP was performed at a gynaecological emergency unit over 3 years. We identified 915 women with a PUL. Initial transvaginal ultrasonography (TVS) findings categorised 187 of the PULs as probable intrauterine pregnancies (IUPs) and 16 as probable EPs. The rate of change in hCG levels over 48 h was calculated for each patient and subjected to three different hCG threshold intervals and a logistic regression model for outcome prediction. Each PUL was subsequently dichotomised to either low-risk (i.e. failed PUL/IUP) or high-risk (i.e. EP) classification, which allowed us to compare the diagnostic performance. In 'Protocol A', a PUL was classified as low risk if >13% hCG level decline or >66% hCG level rise was achieved; otherwise, the PUL was classified as high risk of being an EP. 'Protocol B' classified a PUL as low or high risk using cut-offs of 35-50% declining hCG levels and of 53% rising hCG levels. Similarly, 'Protocol C' used hCG level cut-offs published by NICE, 50% for declining hCG levels and 63% for rising hCG levels. Finally, if a logistic regression model 'Protocol M4' calculated a ≥5% risk of the PUL being an EP, it was classified as high risk, and otherwise the PUL was classified as low risk. When the time interval between two hCG measurements failed to meet an exact 48 h, extrapolation and interpolation of hCG values was made, using log linear transformation. Protocols A, B, C and M4 classified 73, 66, 55 and 56% of PULs as low risk. The sensitivity for protocols A, B, C and M4 was 68% (95% confidence interval (CI) 61-75%), 81% (74-86%), 87% (82-92%) and 88% (83-93%), respectively. The specificity was 82% (80-85%), 77% (74-80%), 66% (62-69%) and 67% (63-70%) for protocols A, B, C and M4, respectively. All comparisons of sensitivity and specificity between the protocols were statistically significant except for protocol C versus protocol M4. In protocol C, 87% (66-97%) of misclassified EPs had rising hCG levels, compared with 19% (6-41%) for protocol M4 (P < 0.01). In a secondary analysis excluding probable IUPs and probable EPs, the results for 712 PULs were analysed. The sensitivity subsequently remained stable for all protocols. Protocol M4 reached a 78% (74-81%) specificity, which was significantly higher than 70% (66-74%) for protocol C (P = 0.01) and protocol M4 classified 63% of PULs as low risk compared with 58% for protocol C. The retrospective design of the study is a limitation. The results are derived from a population where laparoscopy played an important role in PUL management and diagnosis of EPs, although it did reflect real clinical practice. Although we tried to adhere to definitions of PUL and final outcomes as in previous studies and a recent consensus statement, potential differences in this regard must be acknowledged. Where the time interval between two serial hCG measurements deviated from 48 h we estimated 48 h hCG values. A logistic regression model, M4, classifies more PULs correctly as low risk in a selected PUL population without probable IUPs and EPs and identifies as many EPs, in comparison with the cut-offs available in the NICE guideline. This advantage for model M4 may result in a reduction of unnecessary follow-up visits, when fewer low-risk PULs are misclassified as high risk. These findings, however, ought to be clarified in a randomised controlled trial. The study was supported by LUA/ALF grant No. 70940. There are no competing interests. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
[Ethics of research in psychiatry. Comparison of France and the United States].
Lemoine, P; Pacault-Legendre, V
1983-01-01
This article presents a comparison of research ethics in psychopharmacology in France and the United States. The authors present some elements of definition, etymology and of history. In addition, they study how this very specific research is actually done. Many questions are discussed, including the right of the patient, and the problem of normal volunteers. Other aspects are more technical i.e. remuneration, protocol, and the product. Finally the role of the ethics committees is investigated. These committees comprise the third component of the trial that consists of the research and the subject.
Portu, Agustina; Postuma, Ian; Gadan, Mario Alberto; Saint Martin, Gisela; Olivera, María Silvina; Altieri, Saverio; Protti, Nicoletta; Bortolussi, Silva
2015-11-01
An inter-comparison of three boron determination techniques was carried out between laboratories from INFN-University of Pavia (Italy) and CNEA (Argentina): alpha spectrometry (alpha-spect), neutron capture radiography (NCR) and quantitative autoradiography (QTA). Samples of different nature were analysed: liquid standards, liver homogenates and tissue samples from different treatment protocols. The techniques showed a good agreement in a concentration range of interest in BNCT (1-100ppm), thus demonstrating their applicability as precise methods to quantify boron and determine its distribution in tissues. Copyright © 2015 Elsevier Ltd. All rights reserved.
Recommendations for the use of mist nets for inventory and monitoring of bird populations
Ralph, C. John; Dunn, Erica H.; Peach, Will J.; Handel, Colleen M.; Ralph, C. John; Dunn, Erica H.
2004-01-01
We provide recommendations on the best practices for mist netting for the purposes of monitoring population parameters such as abundance and demography. Studies should be carefully thought out before nets are set up, to ensure that sampling design and estimated sample size will allow study objectives to be met. Station location, number of nets, type of nets, net placement, and schedule of operation should be determined by the goals of the particular project, and we provide guidelines for typical mist-net studies. In the absence of study-specific requirements for novel protocols, commonly used protocols should be used to enable comparison of results among studies. Regardless of the equipment, net layout, or netting schedule selected, it is important for all studies that operations be strictly standardized, and a well-written operation protocol will help in attaining this goal. We provide recommendations for data to be collected on captured birds, and emphasize the need for good training of project personnel
Shiravand, Fatemeh; Hutchinson, John M.; Calventus, Yolanda; Ferrando, Francesc
2014-01-01
Three different protocols for the preparation of polymer layered silicate nanocomposites based upon a tri-functional epoxy resin, triglycidyl para-amino phenol (TGAP), have been compared in respect of the cure kinetics, the nanostructure and their mechanical properties. The three preparation procedures involve 2 wt% and 5 wt% of organically modified montmorillonite (MMT), and are: isothermal cure at selected temperatures; pre-conditioning of the resin-clay mixture before isothermal cure; incorporation of an initiator of cationic homopolymerisation, a boron tri-fluoride methyl amine complex, BF3·MEA, within the clay galleries. It was found that features of the cure kinetics and of the nanostructure correlate with the measured impact strength of the cured nanocomposites, which increases as the degree of exfoliation of the MMT is improved. The best protocol for toughening the TGAP/MMT nanocomposites is by the incorporation of 1 wt% BF3·MEA into the clay galleries of nanocomposites containing 2 wt% MMT. PMID:28788672
Nguyen, S M; Thamm, D H; Vail, D M; London, C A
2015-09-01
In veterinary medical oncology, there is currently no standardized protocol for assessing response to therapy in solid tumours. The lack of such a formalized guideline makes it challenging to critically compare outcome measures across various treatment protocols. The Veterinary Cooperative Oncology Group (VCOG) membership consensus document presented here is based on the recommendations of a subcommittee of American College of Veterinary Internal Medicine (ACVIM) board-certified veterinary oncologists. This consensus paper has used the human response evaluation criteria in solid tumours (RECIST v1.1) as a framework to establish standard procedures for response assessment in canine solid tumours that is meant to be easy to use, repeatable and applicable across a variety of clinical trial structures in veterinary oncology. It is hoped that this new canine RECIST (cRECIST v1.0) will be adopted within the veterinary oncology community and thereby facilitate the comparison of current and future treatment protocols used for companion animals with cancer. © 2013 Blackwell Publishing Ltd.
McClements, Jake; McClements, David Julian
2016-06-10
There has been a rapid increase in the fabrication of various kinds of edible nanoparticles for oral delivery of bioactive agents, such as those constructed from proteins, carbohydrates, lipids, and/or minerals. It is currently difficult to compare the relative advantages and disadvantages of different kinds of nanoparticle-based delivery systems because researchers use different analytical instruments and protocols to characterize them. In this paper, we briefly review the various analytical methods available for characterizing the properties of edible nanoparticles, such as composition, morphology, size, charge, physical state, and stability. This information is then used to propose a number of standardized protocols for characterizing nanoparticle properties, for evaluating their stability to environmental stresses, and for predicting their biological fate. Implementation of these protocols would facilitate comparison of the performance of nanoparticles under standardized conditions, which would facilitate the rational selection of nanoparticle-based delivery systems for different applications in the food, health care, and pharmaceutical industries.
Scollo, Francesco; Egea, Leticia A; Gentile, Alessandra; La Malfa, Stefano; Dorado, Gabriel; Hernandez, Pilar
2016-12-15
Olive oil is considered a premium product for its nutritional value and health benefits, and the ability to define its origin and varietal composition is a key step towards ensuring the traceability of the product. However, isolating the DNA from such a matrix is a difficult task. In this study, the quality and quantity of olive oil DNA, isolated using four different DNA isolation protocols, was evaluated using the qRT-PCR and ddPCR techniques. The results indicate that CTAB-based extraction methods were the best for unfiltered oil, while Nucleo Spin-based extraction protocols showed greater overall reproducibility. The use of both qRT-PCR and ddPCR led to the absolute quantification of the DNA copy number. The results clearly demonstrate the importance of the choice of DNA-isolation protocol, which should take into consideration the qualitative aspects of DNA and the evaluation of the amplified DNA copy number. Copyright © 2016 Elsevier Ltd. All rights reserved.
Harding, Krystal M; Dyo, Melissa; Goebel, Joy R; Gorman, Nik; Levine, Julia
2016-08-01
Malnutrition among skilled nursing facility (SNF) patients can lead to hospital readmissions and multiple complications. To evaluate the effect of an existing malnutrition screening and management program on prealbumin levels of patients in skilled nursing facilities. A retrospective design was used to evaluate baseline admission data including a prealbumin level. Patients with malnutrition received an oral protein supplement according to protocol. A comparison prealbumin level was obtained at 30days. Nearly half of the patients were severely malnourished on admission. Patients receiving the prescribed protocol had significantly increased prealbumin levels at 30days than those patients that did not receive the protocol as prescribed. A prealbumin level upon admission at a SNF could represent a reliable tool to evaluate malnutrition. Initiation of an early malnutrition screening and protein supplement program in this setting is essential to identifying and treating at-risk patients before complications occur. Copyright © 2015 Elsevier Inc. All rights reserved.
Potvin, Olivier; Dieumegarde, Louis; Duchesne, Simon
2017-08-01
We recently built normative data for FreeSurfer morphometric estimates of cortical regions using its default atlas parcellation (Desikan-Killiany or DK) according to individual and scanner characteristics. We aimed to produced similar normative values for Desikan-Killianny-Tourville (DKT) and ex vivo-based labeling protocols, as well as examine the differences between these three atlases. Surfaces, thicknesses, and volumes of cortical regions were produced using cross-sectional magnetic resonance scans from the same 2713 healthy individuals aged 18-94 years as used in the reported DK norms. Models predicting regional cortical estimates of each hemisphere were produced using age, sex, estimated intracranial volume (eTIV), scanner manufacturer and magnetic field strength (MFS) as predictors. The DKT and DK models generally included the same predictors and produced similar R 2 . Comparison between DK, DKT, ex vivo atlases normative cortical measures showed that the three protocols generally produced similar normative values. Copyright © 2017 Elsevier Inc. All rights reserved.
Design and Implementation of BDS RTCM SSR Message
NASA Astrophysics Data System (ADS)
Xiao, Xia; Cheng, Fang; Liu, Feng; Lu, XiaoChun
2017-09-01
Based on the real-time differential positioning system of Beidou wide area, a set of Beidou high-precision differential information transmission protocol is studied and designed. After the system generates satellite precise orbit and clock difference products, it needs to be sent to the users in a certain data format through C band GEO communication satellite. The transport protocol should be designed according to the data volume and update rate of the system. At the same time, it is necessary to combine the signal system, satellite resources and the restriction and restriction of the receiver implementation technology. It refers to the relevant fields and international similar systems of technology and standards to design. This paper establishes a set of technical indicators which can measure the pros and cons of differential message organization and broadcasting strategy. Through modeling, simulation and actual test, this paper makes a comprehensive comparison of different strategies. Finally, a transmission protocol design scheme which has good performance and meets the system service requirements is presented.
Comparison between PRP, PRGF and PRF: lights and shadows in three similar but different protocols.
Giannini, S; Cielo, A; Bonanome, L; Rastelli, C; Derla, C; Corpaci, F; Falisi, G
2015-01-01
The main goal of the modern surgery is to get a low invasiveness and a high rate of clinical healing: in the last years, it has been introduced the concept of a "regenerative surgery", and many techniques has been widely described in the literature. The most used are PRP, PRGF and PRF techniques. Aim of this research is to compare the three protocol of PRP, PRF and PRGF in their essential features, so to suggest to the practitioners the best blood product to use in the regenerative surgery. Among the advantages that shows the PRF, compared to PRP and PRGF, we can cite a greater simplicity of production for the absence of manipulation that leads to a reduced possibility of alteration of the protocol due to an error of the operator. The special texture of the PRF and its biological features shows clearly an interesting surgical versatility and all the characteristics that can support a faster tissues regeneration and high-quality clinical outcomes.
Comparison of Two Methods of RNA Extraction from Formalin-Fixed Paraffin-Embedded Tissue Specimens
Gouveia, Gisele Rodrigues; Ferreira, Suzete Cleusa; Ferreira, Jerenice Esdras; Siqueira, Sheila Aparecida Coelho; Pereira, Juliana
2014-01-01
The present study aimed to compare two different methods of extracting RNA from formalin-fixed paraffin-embedded (FFPE) specimens of diffuse large B-cell lymphoma (DLBCL). We further aimed to identify possible influences of variables—such as tissue size, duration of paraffin block storage, fixative type, primers used for cDNA synthesis, and endogenous genes tested—on the success of amplification from the samples. Both tested protocols used the same commercial kit for RNA extraction (the RecoverAll Total Nucleic Acid Isolation Optimized for FFPE Samples from Ambion). However, the second protocol included an additional step of washing with saline buffer just after sample rehydration. Following each protocol, we compared the RNA amount and purity and the amplification success as evaluated by standard PCR and real-time PCR. The results revealed that the extra washing step added to the RNA extraction process resulted in significantly improved RNA quantity and quality and improved success of amplification from paraffin-embedded specimens. PMID:25105117
Shiravand, Fatemeh; Hutchinson, John M; Calventus, Yolanda; Ferrando, Francesc
2014-05-30
Three different protocols for the preparation of polymer layered silicate nanocomposites based upon a tri-functional epoxy resin, triglycidyl para -amino phenol (TGAP), have been compared in respect of the cure kinetics, the nanostructure and their mechanical properties. The three preparation procedures involve 2 wt% and 5 wt% of organically modified montmorillonite (MMT), and are: isothermal cure at selected temperatures; pre-conditioning of the resin-clay mixture before isothermal cure; incorporation of an initiator of cationic homopolymerisation, a boron tri-fluoride methyl amine complex, BF₃·MEA, within the clay galleries. It was found that features of the cure kinetics and of the nanostructure correlate with the measured impact strength of the cured nanocomposites, which increases as the degree of exfoliation of the MMT is improved. The best protocol for toughening the TGAP/MMT nanocomposites is by the incorporation of 1 wt% BF₃·MEA into the clay galleries of nanocomposites containing 2 wt% MMT.
Hieu, Tran Dinh; Duy, Tran Trung; Dung, Le The; Choi, Seong Gon
2018-06-05
To solve the problem of energy constraints and spectrum scarcity for cognitive radio wireless sensor networks (CR-WSNs), an underlay decode-and-forward relaying scheme is considered, where the energy constrained secondary source and relay nodes are capable of harvesting energy from a multi-antenna power beacon (PB) and using that harvested energy to forward the source information to the destination. Based on the time switching receiver architecture, three relaying protocols, namely, hybrid partial relay selection (H-PRS), conventional opportunistic relay selection (C-ORS), and best opportunistic relay selection (B-ORS) protocols are considered to enhance the end-to-end performance under the joint impact of maximal interference constraint and transceiver hardware impairments. For performance evaluation and comparison, we derive the exact and asymptotic closed-form expressions of outage probability (OP) and throughput (TP) to provide significant insights into the impact of our proposed protocols on the system performance over Rayleigh fading channel. Finally, simulation results validate the theoretical results.
SCTP as scalable video coding transport
NASA Astrophysics Data System (ADS)
Ortiz, Jordi; Graciá, Eduardo Martínez; Skarmeta, Antonio F.
2013-12-01
This study presents an evaluation of the Stream Transmission Control Protocol (SCTP) for the transport of the scalable video codec (SVC), proposed by MPEG as an extension to H.264/AVC. Both technologies fit together properly. On the one hand, SVC permits to split easily the bitstream into substreams carrying different video layers, each with different importance for the reconstruction of the complete video sequence at the receiver end. On the other hand, SCTP includes features, such as the multi-streaming and multi-homing capabilities, that permit to transport robustly and efficiently the SVC layers. Several transmission strategies supported on baseline SCTP and its concurrent multipath transfer (CMT) extension are compared with the classical solutions based on the Transmission Control Protocol (TCP) and the Realtime Transmission Protocol (RTP). Using ns-2 simulations, it is shown that CMT-SCTP outperforms TCP and RTP in error-prone networking environments. The comparison is established according to several performance measurements, including delay, throughput, packet loss, and peak signal-to-noise ratio of the received video.
Comparison of gradual and rapid onset runs in a short-arm centrifugation
NASA Astrophysics Data System (ADS)
Miyamoto, A.; Saga, K.; Kinoue, T.; Nakazato, T.; Hirayanagi, K.; Yajima, K.; Hayashi, S.; Matsumoto, S.
A gradual onset run (GOR) in a short-arm centrifugation was performed on ten healthy students. The centrifuge had a 1.8 m radius, and the subjects sat on a chair in a cabin. The Gz force increased to 2.2 Gz at 0.1 °/sec 2 for 32 min. and the same Gz-level was maintained for 20 min. Three out of ten subjects completed the whole protocol; the load on the others was terminated because of symptoms or increased heart rate. There were few symptoms such as vertigo, that was a common problem with a rapid onset run (ROR) in former experiments, due to the short-arm centrifugation. The changes of the flicker test after the load were much less in the GOR protocol than in the ROR protocol, even in the terminated group. GOR seemed preferable to ROR in preventing vertigo even though it took longer to reach the necessary G load.
USDA-ARS?s Scientific Manuscript database
The diversity of in situ soil moisture network protocols and instrumentation led to the development of a testbed for comparing in situ soil moisture sensors. Located in Marena, Oklahoma on the Oklahoma State University Range Research Station, the testbed consists of four base stations. Each station ...
Comparison of intraocular lens types for cataract surgery in eyes with uveitis
Ssemanda, Elizabeth; Lindsley, Kristina; Ervin, Ann-Margret; Kempen, John
2013-01-01
This is the protocol for a review and there is no abstract. The objectives are as follows: The aim of this systematic review is to summarize the effects of different IOLs after cataract surgery in uveitis patients. Alternative types of IOLs include PMMA, silicone, acrylic with or without heparin-surface modification. PMID:25013384
Race and Emotion in Computer-Based HIV Prevention Videos for Emergency Department Patients
ERIC Educational Resources Information Center
Aronson, Ian David; Bania, Theodore C.
2011-01-01
Computer-based video provides a valuable tool for HIV prevention in hospital emergency departments. However, the type of video content and protocol that will be most effective remain underexplored and the subject of debate. This study employs a new and highly replicable methodology that enables comparisons of multiple video segments, each based on…
ERIC Educational Resources Information Center
Lamar, Mary F.; Wilhelm, Jennifer Anne; Cole, Merryn
2018-01-01
The authors compare three teachers' adaptations and implementation of a lunar modeling lesson to explain marked differences in student learning outcomes on a spatial-scientific lunar assessment. They used a modified version of the Practices of Science Observation Protocol (P-SOP; Forbes, Biggers, & Zangori, 2013) to identify ways in which…
Ashraf, Asma; Hadjinicolaou, Andreas V; Doree, Carolyn; Hopewell, Sally; Trivella, Marialena; Estcourt, Lise J
2016-01-01
This is the protocol for a review and there is no abstract. The objectives are as follows: To compare a therapeutic-only versus prophylactic platelet transfusion policy for people with myelodysplasia, inherited or acquired aplastic anaemia, and other congenital bone marrow failure disorders. PMID:27660553
IMPROVE protocol data were collected at the urban Beacon Hill monitoring site in Seattle, WA from 1996-99. The 289 sets of PM2.5 filters were analyzed for: metals using PIXIE and XRF, anions using ion chromatography, elemental hydrogen (H) by proton scattering, and elemental an...
ERIC Educational Resources Information Center
Schandler, Steven L.; Dana, Edward R.
1983-01-01
Examined changes in tension behaviors and reductions in physiological tension associated with cognitive imagery and electromyographic biofeedback relaxation procedures in 45 college students. Results showed: imagery significantly reduced state anxiety. Self-rest was less effective; biofeedback greatly reduced physiological tension, but not state…
ERIC Educational Resources Information Center
Hout, Michael C.; Goldinger, Stephen D.; Ferguson, Ryan W.
2013-01-01
Although traditional methods to collect similarity data (for multidimensional scaling [MDS]) are robust, they share a key shortcoming. Specifically, the possible pairwise comparisons in any set of objects grow rapidly as a function of set size. This leads to lengthy experimental protocols, or procedures that involve scaling stimulus subsets. We…
An anthropomorphic phantom for quantitative evaluation of breast MRI.
Freed, Melanie; de Zwart, Jacco A; Loud, Jennifer T; El Khouli, Riham H; Myers, Kyle J; Greene, Mark H; Duyn, Jeff H; Badano, Aldo
2011-02-01
In this study, the authors aim to develop a physical, tissue-mimicking phantom for quantitative evaluation of breast MRI protocols. The objective of this phantom is to address the need for improved standardization in breast MRI and provide a platform for evaluating the influence of image protocol parameters on lesion detection and discrimination. Quantitative comparisons between patient and phantom image properties are presented. The phantom is constructed using a mixture of lard and egg whites, resulting in a random structure with separate adipose- and glandular-mimicking components. T1 and T2 relaxation times of the lard and egg components of the phantom were estimated at 1.5 T from inversion recovery and spin-echo scans, respectively, using maximum-likelihood methods. The image structure was examined quantitatively by calculating and comparing spatial covariance matrices of phantom and patient images. A static, enhancing lesion was introduced by creating a hollow mold with stereolithography and filling it with a gadolinium-doped water solution. Measured phantom relaxation values fall within 2 standard errors of human values from the literature and are reasonably stable over 9 months of testing. Comparison of the covariance matrices of phantom and patient data demonstrates that the phantom and patient data have similar image structure. Their covariance matrices are the same to within error bars in the anterior-posterior direction and to within about two error bars in the right-left direction. The signal from the phantom's adipose-mimicking material can be suppressed using active fat-suppression protocols. A static, enhancing lesion can also be included with the ability to change morphology and contrast agent concentration. The authors have constructed a phantom and demonstrated its ability to mimic human breast images in terms of key physical properties that are relevant to breast MRI. This phantom provides a platform for the optimization and standardization of breast MRI imaging protocols for lesion detection and characterization.
Yu, Kate; Little, David; Plumb, Rob; Smith, Brian
2006-01-01
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.
Peterson, David A.; Zumberge, Jeremy R.
2006-01-01
Samples of benthic macroinvertebrates were collected side-by-side from riffles at 12 stream sites in Wyoming, Colorado, and Montana during 2000-2001, following protocols established by the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program and the U.S. Environmental Protection Agency Environmental Monitoring and Assessment Program (EMAP). Samples from riffles were collected following NAWQA protocols, using a sampler with 425-micron net mesh-opening size from a total area of 1.25 m2 per sample in multiple riffles. Samples also were collected following EMAP protocols, using a sampler with 500-micron net mesh-opening size from a total area of 0.72 m2 per sample in multiple riffles. The taxonomic identification and enumeration of the samples followed procedures established for each program. Benthic macroinvertebrate community structure was compared between the data sets using individual metrics, a multimetric index, and multivariate analysis. Comparisons between the macroinvertebrate community structures were made after sequentially adjusting both data sets for: (1) ambiguous taxa, (2) taxonomic inconsistencies, and (3) differences in laboratory subsampling. After removal of ambiguous taxa, pair-wise differences in total taxa richness and Ephemeroptera taxa richness were statistically significant (p < 0.05). Differences between the data sets generally were not significant for richness of other taxa, tolerant taxa, semi-voltine taxa, functional feeding groups, diversity, and dominance. Sample scores calculated using the Wyoming Stream Integrity Index were not significantly different between the two data sets. After reconciling both data sets for taxonomic inconsistencies, total taxa richness and Ephemeroptera taxa richness remained significantly different between the data sets. After adjusting the data for differences in laboratory subsampling, the differences in taxa richness were no longer significant. Bray-Curtis similarity coefficients and non-metric multi-dimensional scaling were used to examine macroinvertebrate community structure. Similarity in community structure between sites was affected to a greater extent by taxa reconciliation than by adjustment for subsampling.
Golkar-Narenji, Afsaneh; Gourabi, Hamid; Eimani, Hussein; Barekati, Zeinab; Akhlaghi, Aliasghar
2012-10-01
To study assisted reproductive technology (ART) protocols including superovulation, in vitro fertilization (IVF) and in vitro development (IVD) for BALB/cJ mice in comparison with a common ART protocol for NMRI mice. Adult NMRI and BALB/cJ mice were superovulated using a 48 h G-interval. In order to find a more suitable G-interval for the BALB/cJ strain, G-intervals including 44, 46 and 50 h were also examined. Superovulation rates were recorded in all groups. IVF rate of BALB/c oocytes in T6 and mHTF media were compared. IVD rates of BALB/cJ zygotes in mHTF, T6 and G1V 5 /G2V 5 media were compared. In addition, IVF and IVD rates of BALB/cJ and NMRI oocytes were compared in T6 medium during IVF-IVD procedures. In BALB/cJ mice the highest superovulation rates were observed with 44-46 h G-intervals. However, with a 48 h G-interval, superovulation rates were significantly lower in BALB/cJ compared to NMRI mice ( p < 0.05). mHTF medium significantly increased in vitro fertilization of BALB/cJ oocytes compared to T6 medium ( p < 0.05). Fertilization rate of NMRI oocytes was significantly higher than BALB/cJ oocytes in T6 medium ( p < 0.05). The BALB/cJ embryo IVD was significantly higher in G1/G2 medium compared to mHTF and T6 media ( p < 0.01). Superovulation with 48 h G-interval and using T6 during all in vitro procedures produces embryos more efficiently for NMRI mice than for BALB/cJ mice. For BALB/cJ mice, a protocol including superovulation with a 44-46 h G-interval, using mHTF during IVF and G1V 5 /G2V 5 medium during IVD, may improve in vitro embryo production.
S-EMG signal compression based on domain transformation and spectral shape dynamic bit allocation
2014-01-01
Background Surface electromyographic (S-EMG) signal processing has been emerging in the past few years due to its non-invasive assessment of muscle function and structure and because of the fast growing rate of digital technology which brings about new solutions and applications. Factors such as sampling rate, quantization word length, number of channels and experiment duration can lead to a potentially large volume of data. Efficient transmission and/or storage of S-EMG signals are actually a research issue. That is the aim of this work. Methods This paper presents an algorithm for the data compression of surface electromyographic (S-EMG) signals recorded during isometric contractions protocol and during dynamic experimental protocols such as the cycling activity. The proposed algorithm is based on discrete wavelet transform to proceed spectral decomposition and de-correlation, on a dynamic bit allocation procedure to code the wavelets transformed coefficients, and on an entropy coding to minimize the remaining redundancy and to pack all data. The bit allocation scheme is based on mathematical decreasing spectral shape models, which indicates a shorter digital word length to code high frequency wavelets transformed coefficients. Four bit allocation spectral shape methods were implemented and compared: decreasing exponential spectral shape, decreasing linear spectral shape, decreasing square-root spectral shape and rotated hyperbolic tangent spectral shape. Results The proposed method is demonstrated and evaluated for an isometric protocol and for a dynamic protocol using a real S-EMG signal data bank. Objective performance evaluations metrics are presented. In addition, comparisons with other encoders proposed in scientific literature are shown. Conclusions The decreasing bit allocation shape applied to the quantized wavelet coefficients combined with arithmetic coding results is an efficient procedure. The performance comparisons of the proposed S-EMG data compression algorithm with the established techniques found in scientific literature have shown promising results. PMID:24571620
Effect of Low-Level Laser Therapy and Strength Training Protocol on Hand Grip by Dynamometry
Barbosa, Rafael; Marcolino, Alexandre; Souza, Vitor; Bertolino, Guilherme; Fonseca, Marisa; Guirro, Rinaldo
2017-01-01
Introduction: The purpose of this study was to investigate the effect of low-level laser therapy (LLLT) – 660 nm and 904 nm - before grip strength protocol in healthy subjects. Methods: The study included 45 healthy volunteers with an average age of 22.7 (±1.4) years, subdivided into the following groups, control group: grip strength training associated with placebo LLLT; 660 nm group: LLLT (660 nm, 20 J/cm2, power of 30 mW, and beam area of 0.06 cm2, continuous, energy 1.2 J, and exposure time 40 seconds per point) before grip strength training and 904 nm group: LLLT (904 nm, 10 J/cm2, peak power of 70 W and 0.13 cm2 beam area, with pulsed beam 9.500 Hz and 30 seconds of exposure time per point and emitted energy 1.2 J) before grip strength training. The LLLT was timed to contact 10 points located in the region of the superficial and deep flexor muscles of the fingers, with a total energy of 12.0 J per session. For the strength training protocol, the volunteer exercised their fingers with the dominant hand on a small table, elbow flexed at 90°, forearm in neutral, using a light extension handle. The Oxford protocol was performed during four weeks. The grip strength was assessed using a dynamometer (Jamar™). The data were evaluated by the analysis of variance (ANOVA) statistical method. Results: In the comparison of intragroup evaluation, only the 904 nm group showed a difference compared to the baseline assessment after 4 weeks (P < 0.05), in the final intergroup evaluation, a difference was observed in the comparison between the control and 904 nm groups Conclusion: In conclusion, LLLT (904 nm) applied before resistance training was effective in gaining grip strength when compared to LLLT (660 nm) and isolated strength training after 4 weeks. PMID:29123629
Acute Effects of Drop-Jump Protocols on Explosive Performances of Elite Handball Players.
Dello Iacono, Antonio; Martone, Domenico; Padulo, Johnny
2016-11-01
Dello Iacono, A, Martone, D, and Padulo, J. Acute effects of drop-jump protocols on explosive performances of elite handball players. J Strength Cond Res 30(11): 3122-3133, 2016-This study aimed to assess the acute effects of vertical and horizontal drop jump-based postactivation potentiation (PAP) protocols on neuromuscular abilities in tasks such as jumping, sprinting, and change of direction (COD). Eighteen handball players were assessed before and after PAP regimens, consisting of either vertical single-leg drop-jumps (VDJ) or horizontal single-leg drop-jumps (HDJ) single-leg drop-jumps, on countermovement jump (CMJ), linear sprint, shuttle sprint, and agility performance. The HDJ led to greater improvement of the COD performance in comparison with the VDJ (-6.8 vs. -1.3%; p ≤ 0.05), whereas the VDJ caused greater improvement in the CMJ task compared with the HDJs (+6.5 vs. +1%; p ≤ 0.05). Moreover, the VDJ regimens compared with HDJ induced greater changes in most of the kinetic variables associated with vertical jumping performance, such as peak ground reaction forces (+9.6 vs. +1.3%), vertical displacement (-13.4 vs. -5.3%), leg-spring stiffness (+18.6 vs. +3.6%), contact time (-9.2 vs. -1.3%), and reactive strength index (+7.3 vs. +2.4%) (all comparisons with p ≤ 0.05). Conversely, the HDJ regimens were able to improve the COD performance only by reducing the contact time on COD more than the VDJ (-13.3 vs. -2.4% with p ≤ 0.05). The results showed that both PAPs were able to improve the performances that specifically featured similar force-orientation production. This investigation showed the crucial role that different and specific PAP regimens play in optimizing related functional performances. Specifically oriented vertical and horizontal single-leg drop-jump protocols represent viable means for achieving enhanced explosive-based tasks such as jumping and COD.
NASA Astrophysics Data System (ADS)
Yu, Dong-Su; Cho, Jae-Hwan; Park, Cheol-Soo; Yoo, Heung-Joon; Choi, Cheon-Woong; Kim, Dae-Hyun
2013-10-01
The purpose of this study is to obtain a good quality image and to minimize patient doses and re-examination rates through an optimization of the protocol for coronary computed tomography angiography (CCTA) examination based on a comparison and an analysis of the heart rates (HRs) of patients who had left ventricular ejection fraction (LVEF) values of less than 40% and the HRs of ordinary patients. This study targeted 16 patients who received thallium single-photon emission computed tomography (SPECT) or echocardiography simultaneously among the patients who took the CCTA examinations. Depending on the LVEF value (30 ˜ 39, 40 ˜ 49, 50 ˜ 59, and 60% or above), the patients were divided into groups of four based on HR (50 ˜ 59, 60 ˜ 69, 70 ˜ 79, and 80 or above). DynEva software was used to set the region of interest (ROI) on the ascending aorta and for a measurement of the threshold value. Comparisons and analyses were made based on the LVEF values and the HRs, after which the results were compared with the ones from the existing examination protocols and contrast medium protocols. According to the study results, the relation between the HR and the LVEF demonstrated that it took a long time to reach the true 100 hounsfield unit (HU) when the LVEF was 40% or below. Contrasting media showed significant differences, except in the case where the HR was 80 or above, and/or the LVEF was less than 40%. Moreover, for an LVEF of less than 40%, time differences were significant when contrasting media reached the true 100 HU to begin the scanning process. Therefore, it was possible to predict that the contrasting media were already being washed out from the left ventricle.
Optimization of intra-voxel incoherent motion imaging at 3.0 Tesla for fast liver examination.
Leporq, Benjamin; Saint-Jalmes, Hervé; Rabrait, Cecile; Pilleul, Frank; Guillaud, Olivier; Dumortier, Jérôme; Scoazec, Jean-Yves; Beuf, Olivier
2015-05-01
Optimization of multi b-values MR protocol for fast intra-voxel incoherent motion imaging of the liver at 3.0 Tesla. A comparison of four different acquisition protocols were carried out based on estimated IVIM (DSlow , DFast , and f) and ADC-parameters in 25 healthy volunteers. The effects of respiratory gating compared with free breathing acquisition then diffusion gradient scheme (simultaneous or sequential) and finally use of weighted averaging for different b-values were assessed. An optimization study based on Cramer-Rao lower bound theory was then performed to minimize the number of b-values required for a suitable quantification. The duration-optimized protocol was evaluated on 12 patients with chronic liver diseases No significant differences of IVIM parameters were observed between the assessed protocols. Only four b-values (0, 12, 82, and 1310 s.mm(-2) ) were found mandatory to perform a suitable quantification of IVIM parameters. DSlow and DFast significantly decreased between nonadvanced and advanced fibrosis (P < 0.05 and P < 0.01) whereas perfusion fraction and ADC variations were not found to be significant. Results showed that IVIM could be performed in free breathing, with a weighted-averaging procedure, a simultaneous diffusion gradient scheme and only four optimized b-values (0, 10, 80, and 800) reducing scan duration by a factor of nine compared with a nonoptimized protocol. Preliminary results have shown that parameters such as DSlow and DFast based on optimized IVIM protocol can be relevant biomarkers to distinguish between nonadvanced and advanced fibrosis. © 2014 Wiley Periodicals, Inc.
Beauchamp, Gillian A; Hart, Kimberly W; Lindsell, Christopher J; Lyons, Michael S; Otten, Edward J; Smith, Carol L; Ward, Michael J; Wright, Stewart W
2013-09-01
The availability of 20-h N-acetylcysteine (NAC) infusion for low-risk acetaminophen (APAP) overdose enabled our center to implement an Emergency Department observation unit (OU) protocol as an alternative to hospitalization. Our objective was to evaluate our early experience with this protocol. This retrospective cohort study included all patients treated for low-risk APAP overdose in our academic hospital between 2006 and 2011. Cases were identified using OU and pharmacy records. Successful OU discharge was defined as disposition with no inpatient admission. Differences in medians with 95 % confidence intervals were used for comparisons. One hundred ninety-six patients received NAC for APAP overdose with a mean age of 35 years (SD 14); 73 % were white, and 43 % were male. Twenty (10 %) received care in the OU; 3/20(15 %) met criteria for inclusion in the OU protocol and 13/20(65 %) were discharged successfully. Out of the 196 patients, 10 met criteria for inclusion in the OU protocol but instead received care in the inpatient setting. The median total length of stay from presentation to ED discharge was 41 h for all patients treated in the OU, compared to 68 h for ten patients who met criteria for inclusion in the OU protocol but who were admitted (difference 27 h, 95 % CI 18-72 h). ED observation for APAP overdose can be a viable alternative to inpatient admission. Most patients were successfully discharged from the OU. This evaluation identified both over- and under-utilization of the OU. OU treatment resulted in shorter median length of stay than inpatient admission.
NASA Astrophysics Data System (ADS)
Strocchi, Sabina; Colli, Vittoria; Novario, Raffaele; Carrafiello, Gianpaolo; Giorgianni, Andrea; Macchi, Aldo; Fugazzola, Carlo; Conte, Leopoldo
2007-03-01
Aim of this work is to compare the performances of a Xoran Technologies i-CAT Cone Beam CT for dental applications with those of a standard total body multislice CT (Toshiba Aquilion 64 multislice) used for dental examinations. Image quality and doses to patients have been compared for the three main i-CAT protocols, the Toshiba standard protocol and a Toshiba modified protocol. Images of two phantoms have been acquired: a standard CT quality control phantom and an Alderson Rando ® anthropomorphic phantom. Image noise, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and geometric accuracy have been considered. Clinical image quality was assessed. Effective dose and doses to main head and neck organs were evaluated by means of thermo-luminescent dosimeters (TLD-100) placed in the anthropomorphic phantom. A Quality Index (QI), defined as the ratio of squared CNR to effective dose, has been evaluated. The evaluated effective doses range from 0.06 mSv (i-CAT 10 s protocol) to 2.37 mSv (Toshiba standard protocol). The Toshiba modified protocol (halved tube current, higher pitch value) imparts lower effective dose (0.99 mSv). The conventional CT device provides lower image noise and better SNR, but clinical effectiveness similar to that of dedicated dental CT (comparable CNR and clinical judgment). Consequently, QI values are much higher for this second CT scanner. No geometric distortion has been observed with both devices. As a conclusion, dental volumetric CT supplies adequate image quality to clinical purposes, at doses that are really lower than those imparted by a conventional CT device.
Cohen, Clay; King, Amber; Lin, Chee Paul; Friedman, Gregory K; Monroe, Kathy; Kutny, Matthew
2016-11-01
Patients with febrile neutropenia are at high risk of morbidity and mortality from infectious causes. Decreasing time to antibiotic (TTA) administration is associated with improved patient outcomes. We sought to reduce TTA for children presenting to the emergency department with fever and neutropenia. In a prospective cohort study with historical comparison, TTA administration was evaluated in patients with neutropenia presenting to the Children's of Alabama Emergency Department. A protocol was established to reduce delays in antibiotic administration and increase the percentage of patients who receive treatment within 60 minutes of presentation. One hundred pre-protocol patient visits between August 2010 and December 2011 were evaluated and 153 post-protocol visits were evaluated between August 2012 and September 2013. We reviewed individual cases to determine barriers to rapid antibiotic administration. Antibiotics were administered in 96.9 ± 57.8 minutes in the pre-protocol patient group, and only 35% of patients received antibiotics within 60 minutes of presentation and 70% received antibiotics within 120 minutes. After implementation of the protocol, TTA for neutropenic patients was decreased to 64.3 ± 28.4 minutes (P < 0.0001) with 51.4% receiving antibiotics within 60 minutes and 93.2% within 120 minutes. Implementing a standard approach to patients at risk for neutropenia decreased TTA. There are numerous challenges in providing timely antibiotics to children with febrile neutropenia. Identified delays included venous access (time to effect of topical anesthetics, and difficulty obtaining access), physicians waiting on laboratory results, and antibiotic availability.
Faller, Maximilian; Wilhelmsson, Peter; Kjelland, Vivian; Andreassen, Åshild; Dargis, Rimtas; Quarsten, Hanne; Dessau, Ram; Fingerle, Volker; Margos, Gabriele; Noraas, Sølvi; Ornstein, Katharina; Petersson, Ann-Cathrine; Matussek, Andreas; Lindgren, Per-Eric; Henningsson, Anna J.
2017-01-01
Introduction Lyme borreliosis (LB) is the most common tick transmitted disease in Europe. The diagnosis of LB today is based on the patient´s medical history, clinical presentation and laboratory findings. The laboratory diagnostics are mainly based on antibody detection, but in certain conditions molecular detection by polymerase chain reaction (PCR) may serve as a complement. Aim The purpose of this study was to evaluate the analytical sensitivity, analytical specificity and concordance of eight different real-time PCR methods at five laboratories in Sweden, Norway and Denmark. Method Each participating laboratory was asked to analyse three different sets of samples (reference panels; all blinded) i) cDNA extracted and transcribed from water spiked with cultured Borrelia strains, ii) cerebrospinal fluid spiked with cultured Borrelia strains, and iii) DNA dilution series extracted from cultured Borrelia and relapsing fever strains. The results and the method descriptions of each laboratory were systematically evaluated. Results and conclusions The analytical sensitivities and the concordance between the eight protocols were in general high. The concordance was especially high between the protocols using 16S rRNA as the target gene, however, this concordance was mainly related to cDNA as the type of template. When comparing cDNA and DNA as the type of template the analytical sensitivity was in general higher for the protocols using DNA as template regardless of the use of target gene. The analytical specificity for all eight protocols was high. However, some protocols were not able to detect Borrelia spielmanii, Borrelia lusitaniae or Borrelia japonica. PMID:28937997
Automated selective disruption of slow wave sleep
Ooms, Sharon J.; Zempel, John M.; Holtzman, David M.; Ju, Yo-El S.
2017-01-01
Background Slow wave sleep (SWS) plays an important role in neurophysiologic restoration. Experimentally testing the effect of SWS disruption previously required highly time-intensive and subjective methods. Our goal was to develop an automated and objective protocol to reduce SWS without affecting sleep architecture. New Method We developed a custom Matlab™ protocol to calculate electroencephalogram spectral power every 10 seconds live during a polysomnogram, exclude artifact, and, if measurements met criteria for SWS, deliver increasingly louder tones through earphones. Middle-aged healthy volunteers (n=10) each underwent 2 polysomnograms, one with the SWS disruption protocol and one with sham condition. Results The SWS disruption protocol reduced SWS compared to sham condition, as measured by spectral power in the delta (0.5–4 Hz) band, particularly in the 0.5–2 Hz range (mean 20% decrease). A compensatory increase in the proportion of total spectral power in the theta (4–8 Hz) and alpha (8–12 Hz) bands was seen, but otherwise normal sleep features were preserved. N3 sleep decreased from 20±34 to 3±6 minutes, otherwise there were no significant changes in total sleep time, sleep efficiency, or other macrostructural sleep characteristics. Comparison with existing method This novel SWS disruption protocol produces specific reductions in delta band power similar to existing methods, but has the advantage of being automated, such that SWS disruption can be performed easily in a highly standardized and operator-independent manner. Conclusion This automated SWS disruption protocol effectively reduces SWS without impacting overall sleep architecture. PMID:28238859
Developing and Validating Trace Fear Conditioning Protocols in C57BL/6 Mice
Burman, Michael A; Simmons, Cassandra A; Hughes, Miles; Lei, Lei
2013-01-01
Background Classical fear conditioning is commonly used to study the biology of fear, anxiety and memory. Previous research demonstrated that delay conditioning requires a neural circuit involving the amygdala, but not usually the hippocampus. Trace and contextual fear conditioning require the amygdala and hippocampus. While these paradigms were developed primarily using rat models, they are increasingly being used in mice. New Method The current studies develop trace fear conditioning and control paradigms to allow for the assessment of trace and delay fear conditioning in C57BL/6N mice. Our initial protocol yielded clear delay and contextual conditioning. However, trace conditioning failed to differentiate from an unpaired group and was not hippocampus-dependent. These results suggested that the protocol needed to be modified to specifically accommodate trace conditioning the mice. In order to reduce unconditioned freezing and increase learning, the final protocol was developed by decreasing the intensity of the tone and by increasing the inter-trial interval. Results Our final protocol produced trace conditioned freezing that was significantly greater than that followed unpaired stimulus exposure and was disrupted by hippocampus lesions. Comparison with Existing Methods A review of the literature produced 90 articles using trace conditioning in mice. Few of those articles used any kind of behavioral control group, which is required to rule out non-associative factors causing fearful behavior. Fewer used unpaired groups involving tones and shocks within a session, which is the optimal control group. Conclusions Our final trace conditioning protocol can be used in future studies examining genetically modified C57BL/6N mice. PMID:24269252
Beigi, Manije; Afarande, Fatemeh; Ghiasi, Hosein
2016-01-01
The aim of this study was to compare two bunkers designed by only protocols recommendations and Monte Carlo (MC) based upon data derived for an 18 MV Varian 2100Clinac accelerator. High energy radiation therapy is associated with fast and thermal photoneutrons. Adequate shielding against the contaminant neutron has been recommended by IAEA and NCRP new protocols. The latest protocols released by the IAEA (safety report No. 47) and NCRP report No. 151 were used for the bunker designing calculations. MC method based upon data was also derived. Two bunkers using protocols and MC upon data were designed and discussed. From designed door's thickness, the door designed by the MC simulation and Wu-McGinley analytical method was closer in both BPE and lead thickness. In the case of the primary and secondary barriers, MC simulation resulted in 440.11 mm for the ordinary concrete, total concrete thickness of 1709 mm was required. Calculating the same parameters value with the recommended analytical methods resulted in 1762 mm for the required thickness using 445 mm as recommended by TVL for the concrete. Additionally, for the secondary barrier the thickness of 752.05 mm was obtained. Our results showed MC simulation and the followed protocols recommendations in dose calculation are in good agreement in the radiation contamination dose calculation. Difference between the two analytical and MC simulation methods revealed that the application of only one method for the bunker design may lead to underestimation or overestimation in dose and shielding calculations.
Schindera, Sebastian T; Nelson, Rendon C; Toth, Thomas L; Nguyen, Giao T; Toncheva, Greta I; DeLong, David M; Yoshizumi, Terry T
2008-02-01
The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.