NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
NASA Astrophysics Data System (ADS)
Nour, S.; Karam, L. R.; Inn, K. G. W.
2012-01-01
In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Coplen, Tyler B.
1995-01-01
Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).
Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)
NASA Astrophysics Data System (ADS)
Aslanyan, E.; Herrmann, K.
2013-01-01
This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang
2017-10-11
This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.
Tomatis, Laura; Krebs, Andreas; Siegenthaler, Jessica; Murer, Kurt; de Bruin, Eling D
2015-01-01
Health is closely linked to physical activity and fitness. It is therefore important to monitor fitness in children. Although many reports on physical tests have been published, data comparison between studies is an issue. This study reports Swiss first grade norm values of fitness tests and compares these with criterion reference data. A total of 10,565 boys (7.18 ± 0.42 years) and 10,204 girls (7.14 ± 0.41 years) were tested for standing long jump, plate tapping, 20-m shuttle run, lateral jump and 20-m sprint. Average values for six-, seven- and eight-year-olds were analysed and reference curves for age were constructed. Z-values were generated for comparisons with criterion references reported in the literature. Results were better for all disciplines in seven-year-old first grade children compared to six-year-old children (p < 0.01). Eight-year-old children did not perform better compared to seven-year-old children in the sprint run (p = 0.11), standing long jump (p > 0.99) and shuttle run (p = 0.43), whereas they were better in all other disciplines compared to their younger peers. The average performance of boys was better than girls except for tapping at the age of 8 (p = 0.06). Differences in performance due to testing protocol and setting must be considered when test values from a first grade setting are compared to criterion-based benchmarks. In a classroom setting, younger children tended to have better results and older children tended to have worse outcomes when compared to their age group criterion reference values. Norm reference data are valid allowing comparison with other data generated by similar test protocols applied in a classroom setting.
This document provides graphical arrays and tables of key information on the derivation of human inhalation health effect reference values for specific chemicals, allowing comparisons across durations, populations, and intended use. A number of program offices within the Agency, ...
Choice by value encoding and value construction: processes of loss aversion.
Willemsen, Martijn C; Böckenholt, Ulf; Johnson, Eric J
2011-08-01
Loss aversion and reference dependence are 2 keystones of behavioral theories of choice, but little is known about their underlying cognitive processes. We suggest an additional account for loss aversion that supplements the current account of the value encoding of attributes as gains or losses relative to a reference point, introducing a value construction account. Value construction suggests that loss aversion results from biased evaluations during information search and comparison processes. We develop hypotheses that identify the influence of both accounts and examine process-tracing data for evidence. Our data suggest that loss aversion is the result of the initial direct encoding of losses that leads to the subsequent process of directional comparisons distorting attribute valuations and the final choice.
Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A
2017-12-19
As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.
Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix
NASA Astrophysics Data System (ADS)
Archer, Marcellé; Fernandes-Whaley, Maria; Visser, Ria; de Vos, Jayne; Prins, Sara; Rosso, Adriana; Ruiz de Arechavaleta, Mariana; Tahoun, Ibrahim; Kakoulides, Elias; Luvonga, Caleb; Muriira, Geoffrey; Naujalis, Evaldas; Zakaria, Osman Bin; Buzoianu, Mirella; Bebic, Jelena; Achour Mounir, Ben; Thanh, Ngo Huy
2013-01-01
From within AFRIMETS, the Regional Metrology Organization (RMO) for Africa, the RMO Key Comparison AFRIMETS.QM-K27 was coordinated by the National Metrology Institute of South Africa (NMISA) in 2011. Ten Metrology Institutes participated, comprising three AFRIMETS, two APMP, four EURAMET and one SIM participant. Participants were required to determine the forensic level concentration of two aqueous ethanol solutions that were gravimetrically prepared by the NMISA. Concentrations were expected to lie in the range of 0.1 mg/g to 5.0 mg/g. The accurate determination of ethanol content in aqueous medium is critical for regulatory forensic and trade purposes. The CCQM Organic Analysis Working Group has carried out several key comparisons (CCQM-K27 series) on the determination of ethanol in wine and aqueous matrices. Developing NMIs now had the opportunity to link to the earlier CCQM-K27 studies through the AFRIMETS.QM-K27 study. Gas chromatography coupled to flame ionisation or mass spectrometric detection was applied by eight of the participants, while three participants (including NMISA) applied titrimetry for the ethanol assay. The assigned reference value of the aqueous ethanol solutions was used to link AFRIMETS.QM-K27 to the CCQM-K27 key comparison reference value. The assigned reference values for AFRIMETS.QM-K27 Level 1 and Level 2 were (0.3249 ± 0.0021) mg/g (k = 2) and (4.6649 ± 0.0152) mg/g (k = 2), respectively. The reference values were determined using the purity-corrected gravimetric preparation values, while the standard uncertainty incorporated the gravimetric preparation and titrimetric homogeneity uncertainties. From previous CCQM-K27 studies, the expected spread (%CV) of higher order measurements of ethanol in aqueous medium is about 0.85% relative. In this study the CV for Level 1 is about 12% (10% with two outliers removed) and for Level 2 about 4%. Three of the ten laboratories submitted results within 1.5% of the gravimetric reference value for Level 1; four of the ten participating laboratories submitted mean results within 1.5% of the gravimetric reference value for Level 2. Two of the participating laboratories achieved mean results within 1.5% of the gravimetric reference value for both levels. Participants in the AFRIMETS-K27 study would therefore have benefited from a pilot study in which to test their measurement capability prior to participation in the key comparison. Several NMIs, however, will still be able to make new CMC claims based on their performance in this comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Reference values for exposure of wildlife to contaminants are needed to cost effectively determine if a site is contaminated and to rank sites that are above background levels. Epidemiological techniques originally developed for clinical chemistry and for determining exposures t...
Comparison of z-known GRBs with the Main Groups of Bright BATSE Events
NASA Technical Reports Server (NTRS)
Mitrofanov, Igor G.; Sanin, Anton B.; Anfimov, Dmitrij S.; Litvak, Maxim L.; Briggs, Michael S.; Paciesas, William S.; Pendleton, Geoffrey N.; Preece, Robert D.; Meegan, Charles A.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.
Trial-Type Dependent Frames of Reference for Value Comparison
Hunt, Laurence T.; Woolrich, Mark W.; Rushworth, Matthew F. S.; Behrens, Timothy E. J.
2013-01-01
A central question in cognitive neuroscience regards the means by which options are compared and decisions are resolved during value-guided choice. It is clear that several component processes are needed; these include identifying options, a value-based comparison, and implementation of actions to execute the decision. What is less clear is the temporal precedence and functional organisation of these component processes in the brain. Competing models of decision making have proposed that value comparison may occur in the space of alternative actions, or in the space of abstract goods. We hypothesized that the signals observed might in fact depend upon the framing of the decision. We recorded magnetoencephalographic data from humans performing value-guided choices in which two closely related trial types were interleaved. In the first trial type, each option was revealed separately, potentially causing subjects to estimate each action's value as it was revealed and perform comparison in action-space. In the second trial type, both options were presented simultaneously, potentially leading to comparison in abstract goods-space prior to commitment to a specific action. Distinct activity patterns (in distinct brain regions) on the two trial types demonstrated that the observed frame of reference used for decision making indeed differed, despite the information presented being formally identical, between the two trial types. This provides a potential reconciliation of conflicting accounts of value-guided choice. PMID:24068906
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Wätjen, U; Benedik, L; Spasova, Y; Vasile, M; Altzitzoglou, T; Beyermann, M
2010-01-01
In anticipation of new European requirements for monitoring radioactivity concentration in drinking water, IRMM organized an interlaboratory comparison on the determination of low levels of activity concentrations (about 10-100 mBq L(-1)) of the naturally occurring radionuclides (226)Ra, (228)Ra, (234)U and (238)U in three commercially available mineral waters. Using two or three different methods with traceability to the International System of Reference (SIR), the reference values of the water samples were determined prior to the proficiency test within combined standard uncertainties of the order of 3%-10%. An overview of radiochemical separation and measurement methods used by the 45 participating laboratories are given. The results of the participants are evaluated versus the reference values. Several of the participants' results deviate by more than a factor of two from the reference values, in particular for the radium isotopes. Such erroneous analysis results may lead to a crucial omission of remedial actions on drinking water supplies or to economic loss by an unjustified action. Copyright 2009 Elsevier Ltd. All rights reserved.
University Students' Value Priorities and Emotional Empathy.
ERIC Educational Resources Information Center
Myyry, Liisa; Helkama, Klaus
2001-01-01
Presents a comparison of the Schwartz typology of values and the Spranger-Allport-Vernon typology. Investigates the differences among students in business, social science, and technology in emotional empathy and the relationships of value priorities and emotional empathy in different fields. Includes references. (CMK)
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
International comparison CCQM-K111.1—propane in nitrogen
NASA Astrophysics Data System (ADS)
van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique
2017-01-01
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capability of preparing Primary Standard gas Mixtures (PSMs), performing the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this subsequent key comparison is classified as a track B key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities for propane under the default scheme. The artefact was a binary mixture of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The result of the participating laboratory is consistent with the key comparison reference value within the respective expanded uncertainties and deviates less than 0.1 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Dimbylow, Peter
2005-09-01
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
Dimbylow, Peter
2005-09-07
Finite-difference time-domain (FDTD) calculations have been performed of the whole-body averaged specific energy absorption rate (SAR) in a female voxel model, NAOMI, under isolated and grounded conditions from 10 MHz to 3 GHz. The 2 mm resolution voxel model, NAOMI, was scaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the ICRP reference adult female. Comparison was made with SAR values from a reference male voxel model, NORMAN. A broad SAR resonance in the NAOMI values was found around 900 MHz and a resulting enhancement, up to 25%, over the values for the male voxel model, NORMAN. This latter result confirmed previously reported higher values in a female model. The effect of differences in anatomy was investigated by comparing values for 10-, 5- and 1-year-old phantoms rescaled to the ICRP reference values of height and mass which are the same for both sexes. The broad resonance in the NAOMI child values around 1 GHz is still a strong feature. A comparison has been made with ICNIRP guidelines. The ICNIRP occupational reference level provides a conservative estimate of the whole-body averaged SAR restriction. The linear scaling of the adult phantom using different factors in longitudinal and transverse directions, in order to match the ICRP stature and weight, does not exactly reproduce the anatomy of children. However, for public exposure the calculations with scaled child models indicate that the ICNIRP reference level may not provide a conservative estimate of the whole-body averaged SAR restriction, above 1.2 GHz for scaled 5- and 1-year-old female models, although any underestimate is by less than 20%.
NASA Astrophysics Data System (ADS)
Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.
2011-01-01
In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
EURAMET.M.P-S9 / EURAMET 1170, LOOP2. Comparison in the negative gauge pressure range -950 to 0 hPa
NASA Astrophysics Data System (ADS)
Otal, P.; Boineau, F.; Medina, N.; Pražák, D.; Wüthrich, C.; Saxholm, S.; Sabuga, W.; Kocas, I.; Durgut, Y.
2017-01-01
This report gives the results of a comparison of pressure standards of seven European National Metrology institutes in the range of negative gauge pressure from -950 hPa to 0 hPa. This comparison was piloted by LNE and was carried out from January 2011 to March 2012. This work is a part of the EURAMET project 1170 and is registered as a supplementary comparison EURAMET.M.P-S9. The transfer standard used was a pressure monitor RPM4 A160Ks manufactured by DH Instruments Inc., with a resolution of 0.1 Pa. The reference values have been determined from the weighted mean of the deviations reported by the participants for each specified pressure. Seventy-three of the seventy-seven values (96%) reported by the laboratories agree with the reference values within the expanded uncertainties with a coverage factor k = 2. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John
2014-01-01
The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4
NASA Astrophysics Data System (ADS)
Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.
2008-01-01
Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1
NASA Astrophysics Data System (ADS)
Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.
2008-01-01
Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
The conventional tuning fork as a quantitative tool for vibration threshold.
Alanazy, Mohammed H; Alfurayh, Nuha A; Almweisheer, Shaza N; Aljafen, Bandar N; Muayqil, Taim
2018-01-01
This study was undertaken to describe a method for quantifying vibration when using a conventional tuning fork (CTF) in comparison to a Rydel-Seiffer tuning fork (RSTF) and to provide reference values. Vibration thresholds at index finger and big toe were obtained in 281 participants. Spearman's correlations were performed. Age, weight, and height were analyzed for their covariate effects on vibration threshold. Reference values at the fifth percentile were obtained by quantile regression. The correlation coefficients between CTF and RSTF values at finger/toe were 0.59/0.64 (P = 0.001 for both). Among covariates, only age had a significant effect on vibration threshold. Reference values for CTF at finger/toe for the age groups 20-39 and 40-60 years were 7.4/4.9 and 5.8/4.6 s, respectively. Reference values for RSTF at finger/toe for the age groups 20-39 and 40-60 years were 6.9/5.5 and 6.2/4.7, respectively. CTF provides quantitative values that are as good as those provided by RSTF. Age-stratified reference data are provided. Muscle Nerve 57: 49-53, 2018. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Pozdeeva, Valentina; Chalyy, Vladimir
2014-01-01
The supplementary comparison COOMET.AUV.A-S1 for secondary calibration methods using WS1 and WS2 measurement microphones was carried out from 2009 to 2010. The results were submitted to and approved by CCAUV in April 2014. Four National Metrology Institutes took part in this comparison and are as follows: BelGIM (Belarus), VNIIFTRI (Russia), SMU (Slovakia) and DP NDI 'Sistema' (Ukraine). Three of the above NMIs (VNIIFTRI, SMU and DP NDI 'Sistema') had earlier participated in COOMET key comparisons and one NMI (VNIIFTRI) had also participated in CCAUV key comparisons. The Comparison Reference Values were calculated as the weighted mean values from results obtained by three institutes. The comparison results show agreement for all participants in the frequency range from 20 Hz to 12.5 kHz for WS1 microphones, and in the frequency range from 20 Hz to 16 kHz for WS2 microphones. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors
NASA Astrophysics Data System (ADS)
Xu, Gan; Huang, Xuebo; Liu, Yuanjie
2007-01-01
APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Compositional analysis of biomass reference materials: Results from an interlaboratory study
Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...
2015-10-29
Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original characterization, were quantified here.« less
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Measurement of gauge blocks by interferometry
NASA Astrophysics Data System (ADS)
Matus, M.; Haas, S.; Piree, H.; Gavalyugov, V.; Tamakyarska, D.; Thalmann, R.; Balling, P.; Garnaes, J.; Hald, J.; Farid, N.; Prieto, E.; Lassila, A.; Salgado, J. A.; Lewis, A.; Bandis, C.; Mudronja, V.; Banreti, E.; Balsamo, A.; Pedone, P.; Bergmans, R. H.; Karlsson, H.; Ramotowski, Z.; Eusebio, L.; Saraiva, F.; Duta, A.; Zelenika, S.; Bergstrand, S.; Fira, R.; Yandayan, T.; Sendogdu, D.; Ganioglu, O.; Asli Akgoz, S.; Franke, P.
2016-01-01
The key comparison EURAMET.L-K1.2011 on gauge blocks was carried out in the framework of a EURAMET project starting in 2012 and ending in 2015. It involved the participation of 24 National Metrology Institutes from Europe and Egypt, respectively. 38 gauge blocks of steel and ceramic with nominal central lengths between 0.5 mm and 500 mm were circulated. The comparison was conducted in two loops with two sets of artifacts. A statistical technique for linking the reference values was applied. As a consequence the reference value of one loop is influenced by the measurements of the other loop although they did not even see the artifacts of the others. This influence comes solely from three "linking laboratories" which measure both sets of artifacts. In total there were 44 results were not fully consistent with the reference values. This represents 10% of the full set of 420 results which is a considerable high number. At least 12 of them are clearly outliers where the participants have been informed by the pilot as soon as possible. The comparison results help to support the calibration and measurement capabilities (CMCs) of the laboratories involved in the CIPM MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa
NASA Astrophysics Data System (ADS)
Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.
2016-01-01
A comparison in the negative gauge pressure range was arranged in the period 2011 - 2012. A total of 14 laboratories participated in this comparison: BEV (Austria), CMI (Czech Republic), DANIAmet-FORCE (Denmark), EIM (Greece), HMI/FSB-LPM (Croatia), INM (Romania), IPQ (Portugal), LNE (France), MCCAA (Malta), METROSERT (Estonia), MIKES (Finland), MIRS/IMT/LMT (Slovenia), NSAI (Ireland) and UME (Turkey). The project was divided into two loops: Loop1, piloted by MIKES, and Loop2, piloted by LNE. The results of the two loops are reported separately: Loop1 results are presented in this paper. The transfer standard was Beamex MC5 no. 25516865 with internal pressure module INT1C, resolution 0.01 hPa. The nominal pressure range of the INT1C is -1000 hPa to +1000 hPa. The nominal pressure points for the comparison were 0 hPa, -200 hPa, -400 hPa, -600 hPa, -800 hPa and -950 hPa. The reference values and their uncertainties as well as the difference uncertainty between the laboratory results and the reference values were determined from the measurement data by Monte Carlo simulations. Stability uncertainty of the transfer standard was included in the final difference uncertainty. Degrees of equivalences and mutual equivalences between the laboratories were calculated. Each laboratory reported results for all twelve measurement points, which means that there were 168 reported values in total. Some 163 of the 168 values (97 %) agree with the reference values within the expanded uncertainties, with a coverage factor k = 2. Among the laboratories, four different methods were used to determine negative gauge pressure. It is concluded that special attention must be paid to the measurements and methods when measuring negative gauge pressures. There might be a need for a technical guide or a workshop that provides information about details and practices related to the measurements of negative gauge pressure, as well as differences between the different methods. The comparison is registered as EURAMET project no. 1170 and as a supplementary comparison EURAMET.M.P-S9 in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Quantitative Imaging Biomarkers: A Review of Statistical Methods for Computer Algorithm Comparisons
2014-01-01
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research. PMID:24919829
CCQM K6.2 determination of total cholesterol in human serum
NASA Astrophysics Data System (ADS)
Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pabello, Guiomar; Avila Caldero, Marco A.; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Puglisi, Celia; Lopez, Eduardo; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Heuillet, Maud; Nammoonnoy, Jintana; Ceyhan Gören, Ahmet; Bilsel, Gokhan; Konopelko, L.; Krylov, A.; Lopushanskaya, E.
2018-01-01
Cholesterol is one of the most frequently measured substances in human blood/serum to assist in assessing the health status of individuals. Because of its clinical significance, CCQM-K6 determination of cholesterol in serum was completed in 2000 as one of the first key comparison (KC) studies performed within the Organic Analysis Working Group (OAWG). The first subsequent KC for cholesterol, CCQM-K6.1, was completed in 2001. Measurements for this second subsequent, CCQM-K6.2, were completed in 2012. These subsequent comparisons were conducted to enable CCQM members that had not participated in earlier studies to demonstrate their capabilities to measure a nonpolar (pKow < ‑2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (1 mg/g to 3 mg/g) found in normal populations. Successful participation in CCQM-K6.2 demonstrated capabilities in analysis of complex biological matrices including sample preparation (extraction, derivatization), LC or GC separation, and quantification using an isotope dilution mass spectrometry approach. Normally in a subsequent KC, no key comparison reference value (KCRV) would be established and assessment of performance would be via the deviation of participants' results to the anchor institute's results, adjusted to account for the anchor's performance in the original comparison versus its KCRV. Due to the very long-time period since the original key comparison, the OAWG decided that this did not represent the best approach to assess performance in what is a relatively complex measurement. Given the excellent agreement between the anchor institute's results and robust consensus summary of the participants' values, the reference value for this study was taken as the anchor institute's result and treated as a 'KCRV'. Seven of the nine participants demonstrated agreement with the reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Sport fishing at a thermal discharge into Lake Michigan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spigarelli, S.A.; Thommes, M.M.
1976-07-01
Sport fishing censuses were conducted during 1972 and 1973 at the Point Beach Nuclear Plant on Lake Michigan (Two Rivers, Wisconsin). The objectives of this study were to describe the fishery at a typical shoreline thermal discharge into the upper Great Lakes and to make comparisons with reference fisheries in unheated areas. Extensive sport fishing at this power plant resulted in a relatively large catch of trout (4 species) and sporadic catches of salmon and non-salmonid species. Species composition of the catch and catch-per-unit-effort varied daily and seasonally and generally reflected trends in reference fisheries. A comparison between years showedmore » increased fishing effort, total catch, and proportion of trout in 1973, while success (catch-per-unit-effort) decreased. Despite this heavy fishing pressure, catch-per-unit-effort was generally higher at Point Beach than in reference shoreline fisheries. The economic value of thermal discharge fisheries on Lake Michigan is estimated using available value and expenditure data.« less
APMP.QM-K111—propane in nitrogen
NASA Astrophysics Data System (ADS)
Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Kang, Namgoo; Bae, Hyun Kil; Woo, Jin Chun; Bi, Zhe; Zhou, Zeyi; Sinweeruthai, Ratirat; Wongjuk, Arnuttachai; Li, Hou; Beng Keat, Teo; Hui, Liu; Wu, Thomas; Hock Ann, Chua; Smeulders, Damian; Briton McCallum, John; Tendai Satumba, Raymond; Shimosaka, Takuya; Matsumoto, Nobuhiro; Kadir, Haslina Abdul; Fauzi Ahmad, Mohamad; Nasir, Noor Hidaya Abdul; Nishino, Tomoe; Akima, Dai; Uehara, Shinji
2018-01-01
This document describes the result of a key comparison for propane in nitrogen. The nominal amount-of-substance fraction of propane is 1000 μmol/mol. The comparison aimed to assess the measurement capability of participants in gas analysis. Nine NMIs or DIs participated in the comparison. CERI participated in a key comparison CCQM-K111—propane in nitrogen, and coordinated this key comparison. Therefore, every participants' results of this comparison are linking to the CCQM-K111. Gravimetric values of the samples were used as key comparison reference values (KCRVs). Measured values of eight participants were within +/- 0.25 % of the KCRVs. Many participants reported purity or impurity analysis of materials. These results are also able to assess the participants' capability of the analysis. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2013 CFR
2013-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2012 CFR
2012-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
40 CFR 86.1306-07 - Equipment required and specifications; overview.
Code of Federal Regulations, 2011 CFR
2011-07-01
... alternate and reference averages; these are Asd and Rsd respectively. Asd must be less than or equal to Rsd. If Asd is greater than Rsd, the Administrator will not approve the application. (D) For an unpaired comparison, calculate the t-value: tunpaired = (Aavg−Ravg)/((Asd 2+Rsd 2)/n)1/2 (E) For a paired comparison...
An Evaluation Framework for Lossy Compression of Genome Sequencing Quality Values.
Alberti, Claudio; Daniels, Noah; Hernaez, Mikel; Voges, Jan; Goldfeder, Rachel L; Hernandez-Lopez, Ana A; Mattavelli, Marco; Berger, Bonnie
2016-01-01
This paper provides the specification and an initial validation of an evaluation framework for the comparison of lossy compressors of genome sequencing quality values. The goal is to define reference data, test sets, tools and metrics that shall be used to evaluate the impact of lossy compression of quality values on human genome variant calling. The functionality of the framework is validated referring to two state-of-the-art genomic compressors. This work has been spurred by the current activity within the ISO/IEC SC29/WG11 technical committee (a.k.a. MPEG), which is investigating the possibility of starting a standardization activity for genomic information representation.
Chlorine Dioxide Disinfection in the Use of Individual Water Purification Devices
2006-03-01
CTs ranging from 1.7-17.6 mg-min/L necessary for 2-log Giardia muris cyst inactivation (reference 23). The SWTR provides the following CT values...reference 3). A comparison of CTs required for a 2-log inactivation for E. Coli bacteria, Poliovirus 1, and Giardia cysts showed Giardia cysts were 2-5...Cryptosporidium oocysts are the most resistant, being 8-16 times more resistant than Giardia cysts (reference 5). Chlorine dioxide’s general disinfection
Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2016-01-26
Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.
ERIC Educational Resources Information Center
Georgellis, Yannis; Tsitsianis, Nicholas; Yin, Ya Ping
2009-01-01
Using data from the first two rounds of the European Social Survey, we examine the link between income, reference income and life satisfaction across Western Europe. We find that whilst there is a strong positive relationship between income and life satisfaction, reference or comparison income exerts a strong negative influence. Interestingly, our…
Kaafarani, Mirna; Schroer, Christian; Takken, Tim
2017-12-01
Hemodynamic responses to exercise are used as markers of diagnosis for cardiac diseases, systolic blood pressure (SBP) especially. However, the reference values for SBP in children at peak exertion level are outdated. This study aimed to establish current reference values for SBP, rate pressure product (RPP), and circulatory power (CircP). Data from children who previously underwent cardiopulmonary exercise testing were categorized as healthy (N = 184; age 12.6 ± 2.9 years), and CoA patients (N = 25; age 13.0 ± 3.2 years). With the Lambda-Mu-Sigma (LMS) method, percentile curves were made for SBP, CircP, and RPP in function of peak work rate (Wpeak). Data of CoA patients were used to validate the reference values. Wpeak was the best predictor of peak SBP during exercise. The prediction equations for SBP, CircP and RPP were: (0.2853 x Wpeak) + 111.46; (10.56 x Wpeak) + 2550.2 and (61.879 x Wpeak) + 19.887, respectively. CoA patients showed significantly increased values for peak SBP (Z-score 1.063 ± 1.347). This study provides reference values for SBP, RPP, and CircP at peak exercise. These values can be used for objective evaluation of participants 6-18 years of age in a Dutch population.
NASA Technical Reports Server (NTRS)
Findlay, J. T.; Kelly, G. M.; Troutman, P. A.
1984-01-01
The ambient atmospheric parameter comparisons versus derived values from the first twelve Space Shuttle Orbiter entry flights are presented. Available flights, flight data products, and data sources utilized are reviewed. Comparisons are presented based on remote meteorological measurements as well as two comprehensive models which incorporate latitudinal and seasonal effects. These are the Air Force 1978 Reference Atmosphere and the Marshall Space Flight Center Global Reference Model (GRAM). Atmospheric structure sensible in the Shuttle flight data is shown and discussed. A model for consideration in Aero-assisted Orbital Transfer Vehicle (AOTV) trajectory analysis, proposed to modify the GRAM data to emulate Shuttle experiments.
NASA Astrophysics Data System (ADS)
Ishii, Masanori; Kim, Jeong Hwan; Ji, Yu; Cho, Chi Hyun; Zhang, Tim
2018-01-01
The supplementary comparison report APMP.RF-S21.F describes the comparison of loop antennas, which was conducted between April 2013 and January 2014. The two comparison artefacts were well-characterised active loop antennas of diameter 30 cm and 60 cm respectively, which typically operate in a frequency range from 9 kHz to 30 MHz. These antennas represent the main groups of antennas which are used around the world for EMC measurements in the frequency range below 30 MHz. There are several well-known methods for calibrating the antenna factor of these devices. The calibration systems used in this comparison for the loop antennas employed the standard magnetic field method or the three-antenna method. Despite the limitations of the algorithm, which we used to derive the reference value for each case (particularly for small samples), the actual calculated reference values seem to be reasonable. As a result, the agreement between each participant was very good in all cases. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Avison, Janine; Barham, Richard
2014-01-01
This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Numbers of Beauty: An Innovative Aesthetic Analysis for Orthognathic Surgery Treatment Planning.
Marianetti, Tito Matteo; Gasparini, Giulio; Midulla, Giulia; Grippaudo, Cristina; Deli, Roberto; Cervelli, Daniele; Pelo, Sandro; Moro, Alessandro
2016-01-01
The aim of this study was to validate a new aesthetic analysis and establish the sagittal position of the maxilla on an ideal group of reference. We want to demonstrate the usefulness of these findings in the treatment planning of patients undergoing orthognathic surgery. We took a reference group of 81 Italian women participating in a national beauty contest in 2011 on which we performed Arnett's soft tissues cephalometric analysis and our new "Vertical Planning Line" analysis. We used the ideal values to elaborate the surgical treatment planning of a second group of 60 consecutive female patients affected by skeletal class III malocclusion. Finally we compared both pre- and postoperative pictures with the reference values of the ideal group. The ideal group of reference does not perfectly fit in Arnett's proposed norms. From the descriptive statistical comparison of the patients' values before and after orthognathic surgery with the reference values we observed how all parameters considered got closer to the ideal population. We consider our "Vertical Planning Line" a useful help for orthodontist and surgeon in the treatment planning of patients with skeletal malocclusions, in combination with the clinical facial examination and the classical cephalometric analysis of bone structures.
NASA Astrophysics Data System (ADS)
Michotte, C.; Ratel, G.; Courte, S.; Sochorovà, J.; Auerbach, P.; Keightley, J.; Johansson, L.; Bakhshandeiar, E.; Cassette, P.; Moune, M.; Capogni, M.; De Felice, P.
2013-01-01
Since 2009, four national metrology institutes (NMI) have submitted four samples of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Cu-64. The values of the activity submitted were between about 3 MBq and 260 MBq. There are now five results in the BIPM.RI(II)-K1.Cu-64 comparison. A key comparison reference value (KCRV) has been calculated for the first time for this nuclide. The degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated and the results are given in the form of a table. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Kotlarski, Sven; Gutiérrez, José M.; Boberg, Fredrik; Bosshard, Thomas; Cardoso, Rita M.; Herrera, Sixto; Maraun, Douglas; Mezghani, Abdelkader; Pagé, Christian; Räty, Olle; Stepanek, Petr; Soares, Pedro M. M.; Szabo, Peter
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of downscaling methods. Such assessments can be expected to crucially depend on the existence of accurate and reliable observational reference data. In dynamical downscaling, observational data can influence model development itself and, later on, model evaluation, parameter calibration and added value assessment. In empirical-statistical downscaling, observations serve as predictand data and directly influence model calibration with corresponding effects on downscaled climate change projections. We here present a comprehensive assessment of the influence of uncertainties in observational reference data and of scale-related issues on several of the above-mentioned aspects. First, temperature and precipitation characteristics as simulated by a set of reanalysis-driven EURO-CORDEX RCM experiments are validated against three different gridded reference data products, namely (1) the EOBS dataset (2) the recently developed EURO4M-MESAN regional re-analysis, and (3) several national high-resolution and quality-controlled gridded datasets that recently became available. The analysis reveals a considerable influence of the choice of the reference data on the evaluation results, especially for precipitation. It is also illustrated how differences between the reference data sets influence the ranking of RCMs according to a comprehensive set of performance measures.
Quantitative imaging biomarkers: a review of statistical methods for computer algorithm comparisons.
Obuchowski, Nancy A; Reeves, Anthony P; Huang, Erich P; Wang, Xiao-Feng; Buckler, Andrew J; Kim, Hyun J Grace; Barnhart, Huiman X; Jackson, Edward F; Giger, Maryellen L; Pennello, Gene; Toledano, Alicia Y; Kalpathy-Cramer, Jayashree; Apanasovich, Tatiyana V; Kinahan, Paul E; Myers, Kyle J; Goldgof, Dmitry B; Barboriak, Daniel P; Gillies, Robert J; Schwartz, Lawrence H; Sullivan, Daniel C
2015-02-01
Quantitative biomarkers from medical images are becoming important tools for clinical diagnosis, staging, monitoring, treatment planning, and development of new therapies. While there is a rich history of the development of quantitative imaging biomarker (QIB) techniques, little attention has been paid to the validation and comparison of the computer algorithms that implement the QIB measurements. In this paper we provide a framework for QIB algorithm comparisons. We first review and compare various study designs, including designs with the true value (e.g. phantoms, digital reference images, and zero-change studies), designs with a reference standard (e.g. studies testing equivalence with a reference standard), and designs without a reference standard (e.g. agreement studies and studies of algorithm precision). The statistical methods for comparing QIB algorithms are then presented for various study types using both aggregate and disaggregate approaches. We propose a series of steps for establishing the performance of a QIB algorithm, identify limitations in the current statistical literature, and suggest future directions for research. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Enault, Jérôme; Robert, Samuel; Schlosser, Olivier; de Thé, Catherine; Loret, Jean-François
2015-11-01
This study collated 254,441 analytical results from drinking water quality monitoring in order to compare levels of exposure of the French adult population from drinking water with that from total diet for 37 pesticides, 11 mineral elements, 11 polycyclic aromatic hydrocarbons (PAH), 6 non dioxin-like polychlorobiphenyls (NDL PCB), 5 ether polybromodiphenyl ethers (BDE), 2 perfluorinated compounds. It also compares levels of exposure from drinking water with that from inhalation of indoor air for 9 volatile organic compounds (VOC) and 3 phthalates. The vast majority of the water analysis results showed values below the limits of quantification and this comparison was primarily made on the basis of a highly pessimistic scenario consisting in considering the data below the limits of quantification as being equal to the limits of quantification. With this conservative scenario, it can be seen that tap water makes a minor but potentially non-negligible contribution for a few micropollutants, by comparison with diet and air. It also shows that exposure through drinking water remains below the toxicity reference values for these substances. Apart from a few extreme values reflecting exceptional local situations, the concentrations measured for the minority of positive samples (below the 95th percentile value) suggest a very low risk for human health. Lower limits of quantification would however be of use in better estimating the safety margin with regard to the toxicity reference values, in particular for BDE, PAH and NDL PCB. Copyright © 2015 Elsevier GmbH. All rights reserved.
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Key comparison of liquid density standards
NASA Astrophysics Data System (ADS)
Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael
2015-01-01
Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Gerber, Iann C; Jolibois, Franck
2015-05-14
Chemical shift requires the knowledge of both the sample and a reference magnetic shielding. In few cases as nitrogen (15N), the standard experimental reference corresponds to its liquid phase. Theoretical estimate of NMR magnetic shielding parameters of compounds in their liquid phase is then mandatory but usually replaced by an easily-get gas phase value, forbidding direct comparisons with experiments. We propose here to combine ab initio molecular dynamic simulations with the calculations of magnetic shielding using GIAO approach on extracted cluster's structures from MD. Using several computational strategies, we manage to accurately calculate 15N magnetic shielding of nitromethane in its liquid phase. Theoretical comparison between liquid and gas phase allows us to extrapolate an experimental value for the 15N magnetic shielding of nitromethane in gas phase between -121.8 and -120.8 ppm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valoppi, L.; Carlisle, J.; Polisini, J.
1995-12-31
A component of both human health and ecological risk assessments is the evaluation of toxicity values. A comparison between the methodology for the development of Reference Doses (RfDs) to be protective of humans, and that developed for vertebrate wildlife species is presented. For all species, a chronic No Observable Adverse Effect Level (NOAEL) is developed by applying uncertainty factors (UFs) to literature-based toxicity values. Uncertainty factors are used to compensate for the length of exposure, sensitivity of endpoints, and cross-species extrapolations between the test species and the species being assessed. Differences between human and wildlife species could include the toxicologicalmore » endpoint, the critical study, and the magnitude of the cross-species extrapolation factor. Case studies for select chemicals are presented which contrast RfDs developed for humans and those developed for avian and mammalian wildlife.« less
Biometric Subject Verification Based on Electrocardiographic Signals
NASA Technical Reports Server (NTRS)
Dusan, Sorin V. (Inventor); Jorgensen, Charles C. (Inventor)
2014-01-01
A method of authenticating or declining to authenticate an asserted identity of a candidate-person. In an enrollment phase, a reference PQRST heart action graph is provided or constructed from information obtained from a plurality of graphs that resemble each other for a known reference person, using a first graph comparison metric. In a verification phase, a candidate-person asserts his/her identity and presents a plurality of his/her heart cycle graphs. If a sufficient number of the candidate-person's measured graphs resemble each other, a representative composite graph is constructed from the candidate-person's graphs and is compared with a composite reference graph, for the person whose identity is asserted, using a second graph comparison metric. When the second metric value lies in a selected range, the candidate-person's assertion of identity is accepted.
Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M
2010-05-01
Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.
Khan, Muhammad Khalid; Khan, Muhammad Farid; Mustafa, Ghulam; Sualah, Mohammed
2012-01-01
Ciprofloxacin was given orally to 28 healthy male volunteers for single oral dose of 500mg; Plasma samples were collected at different time's interval between 0 and 12h and analyzed both by high pressure liquid chromatography and by a microbiological assay. The detection limits (LOD) were 0.02μg/ml and 0.1μg/ml, for both methods respectively. For each method, coefficients of variation (R(2)) were 0.9995 and 0.9918 in plasma and limit of quantitation (LOQ).02 and 0.5μg/ml. The Comparison of means maximum concentration 2.68 μg/ml at 1.5 hr for test and 2.43 μg/ml are attain in HPLC method of Reference at 2hrs respectively. The plasma concentrations measured by microbiological assay of reference tablet are 3.95μg/ml (mean ± SE) at 1 hour and 3.80μg/ml (mean ± SE) at 1 hour. The concentrations in plasma measured by microbiological method were markedly higher than the high-pressure liquid chromatography values which indicates the presence of antimicrobially active metabolites. The mean ± SE values of pharmacokinetic parameters calculated by HPLC method, for total area under the curve (AUC 0-oo) were 13.11, and 11.91 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 44.91 and 48.42 respectively. The elimination rate constant Kel [l/h] showed 0.17 l/h for test and 0.15 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.67 h for test and 1.04 h for reference respectively. The Mean Residence Time for test is 5.48 h and 5.49 h for reference. The mean ± SE values of pharmacokinetic parameters (Microbiological assay) for total area under the curve (AUC 0-oo) were 22.11 and 19.33 h.mg/l for both test and reference tablets respectively. The mean ± SE values of clearance measured in l/h were 29.02 and 31.63 respectively. The elimination rate constant Kel [l/h] showed 0.21 l/h for test and 0.20 l/h reference tablets and likewise, absorption half-life expressed in hours shown 0.86h for test and 0.56 h for reference respectively. The Mean Residence Time for test is 5.27 h and 4.67 h for reference. Significant difference observed between two methods.
Determination of reference ranges for elements in human scalp hair.
Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W
1998-06-01
Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.
NASA Astrophysics Data System (ADS)
Norranim, Uthai; Nguyen, Mong Kim; Ballico, Mark J.
2007-01-01
Industrial thermometers such as industrial platinum resistance thermometers (iprts) and liquid-in-glass thermometers (LIGTs) are widely used in industry. Because Key Comparisons are limited to direct realizations of ITS-90, and not all APMP NMIs have participated in them, the national metrology institutes (NMIs) of Thailand and Australia (NIMT and NIMA) organized an APMP supplementary comparison to support the approval of CMCs (calibration and measurement capabilities) for these laboratories. The comparison, performed in 2003, covered the range from -40.0 °C to 250.0 °C, using IPRTs (Hart Scientific 5626-12-S), total immersion (ASTM 62C, 120C) and partial immersion (ASTM 40C) LIGTs. Ten NMIs from the APMP: KIM-LIPI (Indonesia), ITDI (Philippines), MSL (New Zealand), NBSM (Nepal), NMIA (Australia), NIMT (Thailand), SCL (Hong Kong), SIRIM (Malaysia), SPRING (Singapore) and VMI (Vietnam) were divided into two loops to shorten the circulation time, and these were linked by the two pilot laboratories. This report describes details of the artifacts, the circulation schedule, the measurement procedures, the results submitted by participants, uncertainties and the analysis of the results. Reference values calculated using simple mean, median and weighted mean were consistent with each other, but as the Birge criterion was satisfied, the weighted mean with its lower uncertainty was adopted. The artifacts were found to be stable over the comparison and the results of the loop linking labs consistent, allowing an uncertainty of 2 mK to 4 mK to be achieved for the IPRT reference value and 10 mK to 20 mK for the LIGT reference values. These uncertainties allowed the comparison data to be used to adequately test the uncertainties of all the participant laboratories, and hence to directly support their CMC claims. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
NASA Astrophysics Data System (ADS)
Metairon, S.; Zamboni, C. B.; Suzuki, M. F.; Júnior, C. R. B.; Sant'Anna, O. A.
2011-08-01
The Br, Ca, Cl, K, Na and S concentrations in whole blood of DMDmdx/J and C57BL/6J mice were determined using Neutron Activation Analysis technique. Reference values obtained from twenty one whole blood samples of these strains were analyzed in the IEA-R1 nuclear reactor at IPEN (São Paulo, Brasil). These data contribute for applications in veterinary medicine related to biochemistry analyses using whole blood as well as to evaluate the performance of treatments in muscular dystrophy.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Calhoun, Peter; Lum, John; Beck, Roy W; Kollman, Craig
2013-09-01
Knowledge of the accuracy of continuous glucose monitoring (CGM) devices is important for its use as a management tool for individuals with diabetes and for its use to assess outcomes in clinical studies. Using data from several inpatient studies, we compared the accuracy of two sensors, the Medtronic Enlite™ using MiniMed Paradigm(®) Veo™ calibration and the Sof-Sensor(®) glucose sensor using Guardian(®) REAL-Time CGM calibration (all from Medtronic Diabetes, Northridge, CA). Nocturnal data were analyzed from eight inpatient studies in which both CGM and reference glucose measurements were available. The analyses included 1,666 CGM-reference paired glucose values for the Enlite in 54 participants over 69 nights and 3,627 paired values for the Sof-Sensor in 66 participants over 91 nights. The Enlite sensor tended to report glucose levels lower than the reference over the entire range of glucose values, whereas the Sof-Sensor values tended to be higher than reference values in the hypoglycemic range and lower than reference values in the hyperglycemic range. The overall median sensor-reference difference was -15 mg/dL for the Enlite and -1 mg/dL for the Sof-Sensor (P<0.001). The median relative absolute difference was 15% for the Enlite versus 12% for the Sof-Sensor (P=0.06); 66% of Enlite values and 73% of Sof-Sensor values met International Organization for Standardization criteria. We found that the Enlite tended to be biased low over the entire glucose range, whereas the Sof-Sensor showed the more typical sensor pattern of being biased high in the hypoglycemic range and biased low in the hyperglycemic range.
Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H
2012-01-01
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.
Iacone, Roberto; Scanzano, Clelia; Santarpia, Lidia; D'Isanto, Anna; Contaldo, Franco; Pasanisi, Fabrizio
2016-03-31
The micronutrient content in standard enteral mixtures should be closer to the dietary reference values for a healthy population since standard enteral diets are formulated for subjects with no special nutritional needs. This study compares the micronutrient content of the most common enteral nutrition (EN) formulas with European dietary reference values (DRVs) for healthy population. Sixty-two nutritionally complete enteral formulas were considered. The micronutrient content was calculated by multiplying the value reported on the nutritional information panel of each formula by the daily dose usually prescribed. The comparison between the micronutrient content of all enteral formulas evaluated and the DRVs indicates that daily fluoride and vitamin K requirements were not covered, while an oversupply of many other micronutrients was provided. Moreover, in some enteral formulas, at a dose of 2000 Kcal/day, zinc and vitamin A content exceeded the tolerable upper limits and, for one diabetes-specific enteral formula, the chromium content exceeded the relevant European standards in both 1500 and 2000 Kcal/day diets. Most enteral formulas evaluated are generally suitable for patients on long-term total EN and formulas with higher content of a specific micronutrient may be a useful tool for patients affected by specific clinical conditions, at least for a period of time, then switching to standard enteral mixtures. The availability of nutritional enteral formulas, well balanced also for micronutrient intake, will further improve individualized treatments, particularly for patients on long-term total EN.
International comparison of activity measurements of a solution of 75Se
NASA Astrophysics Data System (ADS)
Ratel, Guy
2002-04-01
Activity measurements of a solution of 75Se, supplied by the BIPM, have been carried out by 21 laboratories within the framework of an international comparison. Seven different methods were used. Details on source preparation, experimental facilities and counting data are reported. The measured activity-concentration values show a total spread of 6.62% before correction and 6.02% after correction for delayed events, with standard deviations of the unweighted means of 0.45% and 0.36%, respectively. The correction for delayed events was measured directly by four laboratories. Unfortunately no consensus on the activity value could be deduced from their results. The results of the comparison have been entered in the tables of the International Reference System (SIR) for γ-ray emitting radionuclides. The half-life of the metastable state was also determined by two laboratories and found to be in good agreement with the values found in the literature.
Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa
NASA Astrophysics Data System (ADS)
Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook
2015-01-01
This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
2002-01-01
This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations. The first section of the report provides summary tables of all the anatomical and physiological parameters given as reference values in this publication. These results give a comprehensive view of reference values for an individual as influenced by age and gender. The second section describes characteristics of dosimetric importance for the embryo and fetus. Information is provided on the development of the total body and the timing of appearance and development of the various organ systems. Reference values are provided on the mass of the total body and selected organs and tissues, as well as a number of physiological parameters. The third section deals with reference values of important anatomical and physiological characteristics of reference individuals from birth to adulthood. This section begins with details on the growth and composition of the total body in males and females. It then describes and quantifies anatomical and physiological characteristics of various organ systems and changes in these characteristics during growth, maturity, and pregnancy. Reference values are specified for characteristics of dosimetric importance. The final section gives a brief summary of the elemental composition of individuals. Focusing on the elements of dosimetric importance, information is presented on the body content of 13 elements: calcium, carbon, chloride, hydrogen, iodine, iron, magnesium, nitrogen, oxygen, potassium, sodium, sulphur, and phosphorus.
Ma, Jun; Wang, Zhiqiang; Song, Yi; Hu, Peijin; Zhang, Bing
2010-12-01
To establish BMI percentile curves that describe the contemporary BMI distribution among Chinese children, and to compare their BMI percentile curves with those in two recently developed international references: the WHO and the US Centers for Disease Control and Prevention (US CDC) growth references. A cross-sectional national survey. Thirty provinces, municipalities and autonomous regions in China. Nationally representative sample of 232 140 school students aged 7-18 years. BMI percentile curves were established using the LMS method, and were compared with the percentiles of the WHO and the US CDC references. BMI distributions and growth patterns in Chinese children were dramatically different from those in the two international reference populations. Compared with the international reference populations, younger Chinese boys (7-12 years of age) had higher values of the percentiles above the median and lower values of the percentiles below the median, suggesting that they had larger proportions of extreme BMI values in both directions. Chinese girls and older Chinese boys (15-18 years of age) had substantially lower BMI percentiles than their counterparts in the reference populations, particularly those high percentiles among older age groups. The present study described the unique patterns of BMI curves at the national level, and these curves are useful as a reference for comparing different regions and for monitoring changes over time in Chinese children. Higher proportions of children with extreme values in both directions indicate that China is currently facing both an increasing level of obesity and a high level of undernutrition, simultaneously.
O’Brien, M.; Lamperti, P.; Williams, T.; Sander, T.
2000-01-01
A direct comparison was made between the air kerma primary standards used for the measurements of low-energy x rays at the National Institute of Standards and Technology (NIST) and the National Physical Laboratory (NPL). The comparison was conducted at the NPL using NPL reference radiation qualities between 10 kV and 80 kV. The results show the primary air-kerma standards to agree within 0.6 % of their values for beam qualities up to 80 kV. PMID:27551632
Nilsson, Markus; Szczepankiewicz, Filip; van Westen, Danielle; Hansson, Oskar
2015-01-01
Conventional motion and eddy-current correction, where each diffusion-weighted volume is registered to a non diffusion-weighted reference, suffers from poor accuracy for high b-value data. An alternative approach is to extrapolate reference volumes from low b-value data. We aim to compare the performance of conventional and extrapolation-based correction of diffusional kurtosis imaging (DKI) data, and to demonstrate the impact of the correction approach on group comparison studies. DKI was performed in patients with Parkinson's disease dementia (PDD), and healthy age-matched controls, using b-values of up to 2750 s/mm2. The accuracy of conventional and extrapolation-based correction methods was investigated. Parameters from DTI and DKI were compared between patients and controls in the cingulum and the anterior thalamic projection tract. Conventional correction resulted in systematic registration errors for high b-value data. The extrapolation-based methods did not exhibit such errors, yielding more accurate tractography and up to 50% lower standard deviation in DKI metrics. Statistically significant differences were found between patients and controls when using the extrapolation-based motion correction that were not detected when using the conventional method. We recommend that conventional motion and eddy-current correction should be abandoned for high b-value data in favour of more accurate methods using extrapolation-based references.
NASA Astrophysics Data System (ADS)
Svitlov, S. M.
2010-06-01
A recent paper (Baumann et al 2009 Metrologia 46 178-86) presents a method to evaluate the free-fall acceleration at a desired point in space, as required for the watt balance experiment. The claimed uncertainty of their absolute gravity measurements is supported by two bilateral comparisons using two absolute gravimeters of the same type. This comment discusses the case where absolute gravity measurements are traceable to a key comparison reference value. Such an approach produces a more complete uncertainty budget and reduces the risk of the results of different watt balance experiments not being compatible.
Selk Ghaffari, Masoud; Sabzevari, Amin; Ghamsari, SeyedMehdi; Shad, Hussein
2017-11-25
This study was conducted to establish normal reference range for the Schirmer tear test (STT) and intraocular pressure (IOP) in clinically normal donkeys for use in clinical practice. Sixteen adult Ethiopian domestic donkeys were used in this study. Complete ophthalmic examinations were performed without chemical restraint. STT values were evaluated in both eyes of all donkeys using a commercial STT strip. IOP was measured in both eyes with a Tono-Pen Vet (Reichert. USA) without using regional nerve blocks. STT values for all eyes (n=32) were 22.1±6.9 mm/minute with a range of 13-35 mm/minute. Comparison of mean STT values between right (n=16) and left eyes (n=16) showed no differences (P=0.6). Mean ±sd IOP values by applanation tonometry were 17.8±3.7 mmHg (range 13.5-24.5 mmHg). Comparison of mean IOP values between right (n=16) and left eyes (n=16) showed no differences (P=0.7). This initial survey provides means and ranges for IOP and STT values in donkeys. These data will assist veterinary ophthalmologists in more accurate diagnosis and management of ophthalmic diseases in donkeys, including keratoconjunctivitis sicca and glaucoma. © British Veterinary Association (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Shafiee, Gita; Ostovar, Afshin; Heshmat, Ramin; Keshtkar, Abbas Ali; Sharifi, Farshad; Shadman, Zhaleh; Nabipour, Iraj; Soltani, Akbar; Larijani, Bagher
2018-01-01
Sacopenia is a common problem in elderly with the adverse outcomes. The objective of this study was to estimate the peak appendicular skeletal muscle mass (ASM) and age of its attainment by sex among the Iranian population. A total of 691 men and women aged 18-94 years participated in this cross-sectional, population-based study in Bushehr, Iran. ASM was measured by dual X-ray absorptiometry. Cutoff points for men and women were established considering two standard deviations (SDs) below the mean values of the skeletal muscle index (SMI) for young reference groups. The relationship between ASM and age was described by the second-degree regression models. Two SDs below the mean SMIs of reference groups were as cutoff values of low muscle mass in Iranian population. The peak ASM values were 21.35 ± 0.12 Kg and 13.68 ± 0.10 Kg, and the age at peak ASM were 26 (24-28) years and 34 (33-35) years for men and women, respectively. Mean and SD of SMI in those ages were 7.01 ± 0.02 Kg/m 2 and 5.44 ± 0.02 Kg/m 2 among men and women, respectively. Calculated cutoff values of low muscle mass among the Iranian population were 7.0 Kg/m 2 and 5.4 Kg/m 2 among men and women, respectively. Iranian reference values of SMI for both genders were similar to Asia Working Group for Sarcopenia recommendation and lower than the United States and European values. Further studies from different nations and the Middle East countries are needed to obtain reference values for populations, enabling the researchers for comparison and also more valid reports on sarcopenia prevalence.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Synchronization trigger control system for flow visualization
NASA Technical Reports Server (NTRS)
Chun, K. S.
1987-01-01
The use of cinematography or holographic interferometry for dynamic flow visualization in an internal combustion engine requires a control device that globally synchronizes camera and light source timing at a predefined shaft encoder angle. The device is capable of 0.35 deg resolution for rotational speeds of up to 73 240 rpm. This was achieved by implementing the shaft encoder signal addressed look-up table (LUT) and appropriate latches. The developed digital signal processing technique achieves 25 nsec of high speed triggering angle detection by using direct parallel bit comparison of the shaft encoder digital code with a simulated angle reference code, instead of using angle value comparison which involves more complicated computation steps. In order to establish synchronization to an AC reference signal whose magnitude is variant with the rotating speed, a dynamic peak followup synchronization technique has been devised. This method scrutinizes the reference signal and provides the right timing within 40 nsec. Two application examples are described.
Realization of the medium and high vacuum primary standard in CENAM, Mexico
NASA Astrophysics Data System (ADS)
Torres-Guzman, J. C.; Santander, L. A.; Jousten, K.
2005-12-01
A medium and high vacuum primary standard, based on the static expansion method, has been set up at Centro Nacional de Metrología (CENAM), Mexico. This system has four volumes and covers a measuring range of 1 × 10-5 Pa to 1 × 103 Pa of absolute pressure. As part of its realization, a characterization was performed, which included volume calibrations, several tests and a bilateral key comparison. To determine the expansion ratios, two methods were applied: the gravimetric method and the method with a linearized spinning rotor gauge. The outgassing ratios for the whole system were also determined. A comparison was performed with Physikalisch-Technische Bundesanstalt (comparison SIM-Euromet.M.P-BK3). By means of this comparison, a link has been achieved with the Euromet comparison (Euromet.M.P-K1.b). As a result, it is concluded that the value obtained at CENAM is equivalent to the Euromet reference value, and therefore the design, construction and operation of CENAM's SEE-1 vacuum primary standard were successful.
Fidler Mis, Nataša; Kobe, Helena; Stimec, Matevž
2012-01-01
Data on a nationally representative dietary intake in Central Europe is lacking. We investigated the diet of adolescents in Slovenia. Dietary habits were assessed using a food frequency questionnaire (n = 2,661), and present nutrition was assessed using a 3-day weighted dietary protocol (n = 197) for validation purposes. Dietary intake was calculated and compared with Central European [German (D), Austrian (A), and Swiss (CH); D-A-CH] recommendations and World Health Organization/Food and Agriculture Organization (WHO/FAO) recommendations. Adolescents consumed exceeding reference intake values of free sugars (boys 16% of energy, girls 17%), saturated fatty acids (SFA; 13% of energy), and sodium (boys 203%, girls 210% of the WHO/FAO upper limit), but below-reference intake values of polyunsaturated fatty acids (PUFA; boys 5% of energy; girls 6%), water (boys 1,786 ml/day, girls 2,016 ml/day), and fiber density (only girls 2.8 g/MJ, p < 0.001). Among micronutrients, below-reference intakes (% of D-A-CH: boys and girls, respectively, p < 0.05) were reported for folate (64 and 69%), fluoride (28 and 31%), and calcium (91 and 97%), as well as for vitamin D (20 and 20%). The dietary habits of Slovenian adolescents are less than optimal. They are characterized by exceeding reference intake values of free sugars, salt, and SFA, and a below-reference intake of PUFA, water, and several micronutrients. Copyright © 2012 S. Karger AG, Basel.
Dilution and permeation standards for the generation of NO, NO2 and SO2 calibration gas mixtures
NASA Astrophysics Data System (ADS)
Haerri, H.-P.; Macé, T.; Waldén, J.; Pascale, C.; Niederhauser, B.; Wirtz, K.; Stovcik, V.; Sutour, C.; Couette, J.; Waldén, T.
2017-03-01
The evaluation results of the metrological performance of a dilution and a permeation standard for generating SI-traceable calibration gas mixtures of NO, SO2 and NO2 for ambient air measurements are presented. The composition of the in situ produced reference gas mixtures is calculated from the instantaneous values of the input quantities of the generating standards. In a measurement comparison, the calibration and measurement capabilities of five laboratories were evaluated for the three analytes at limiting amount of substance fractions in ambient air between 20 and 150 nmol mol-1. For the upper generated reference values the target relative uncertainties of ⩽2% (for NO and SO2) and ⩽3% (for NO2) for evaluating the laboratory results were fulfilled in 12 out of 13 cases. For the analytical results seven out of nine laboratories met the criteria for the upper values for NO and NO2, for SO2 it was one out of four. From the negative degrees of equivalence of all NO2 comparison results it was supposed that the permeation rate of NO2 through the FEP polymer membrane of the permeator was different in air and N2. Subsequent precision permeation measurements with various carrier gases revealed that the permeation rate of NO2 was ≈0.8% lower in synthetic air compared to N2. With the corrected NO2 reference values for air the degrees of equivalence of the laboratory results were improved and closer to be symmetrically distributed.
Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen
2006-01-01
OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726
Automation of the Image Analysis for Thermographic Inspection
NASA Technical Reports Server (NTRS)
Plotnikov, Yuri A.; Winfree, William P.
1998-01-01
Several data processing procedures for the pulse thermal inspection require preliminary determination of an unflawed region. Typically, an initial analysis of the thermal images is performed by an operator to determine the locations of unflawed and the defective areas. In the present work an algorithm is developed for automatically determining a reference point corresponding to an unflawed region. Results are obtained for defects which are arbitrarily located in the inspection region. A comparison is presented of the distributions of derived values with right and wrong localization of the reference point. Different algorithms of automatic determination of the reference point are compared.
New reference materials for nitrogen-isotope-ratio measurements
Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.
1993-01-01
Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.
Zgarbová, Marie; Otyepka, Michal; Sponer, Jirí; Hobza, Pavel; Jurecka, Petr
2010-09-21
The intermolecular interaction energy components for several molecular complexes were calculated using force fields available in the AMBER suite of programs and compared with Density Functional Theory-Symmetry Adapted Perturbation Theory (DFT-SAPT) values. The extent to which such comparison is meaningful is discussed. The comparability is shown to depend strongly on the intermolecular distance, which means that comparisons made at one distance only are of limited value. At large distances the coulombic and van der Waals 1/r(6) empirical terms correspond fairly well with the DFT-SAPT electrostatics and dispersion terms, respectively. At the onset of electronic overlap the empirical values deviate from the reference values considerably. However, the errors in the force fields tend to cancel out in a systematic manner at equilibrium distances. Thus, the overall performance of the force fields displays errors an order of magnitude smaller than those of the individual interaction energy components. The repulsive 1/r(12) component of the van der Waals expression seems to be responsible for a significant part of the deviation of the force field results from the reference values. We suggest that further improvement of the force fields for intermolecular interactions would require replacement of the nonphysical 1/r(12) term by an exponential function. Dispersion anisotropy and its effects are discussed. Our analysis is intended to show that although comparing the empirical and non-empirical interaction energy components is in general problematic, it might bring insights useful for the construction of new force fields. Our results are relevant to often performed force-field-based interaction energy decompositions.
CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s
NASA Astrophysics Data System (ADS)
Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio
2017-01-01
The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Yao, Dezhong; Wang, Li; Arendt-Nielsen, Lars; Chen, Andrew C N
2007-11-01
Reference is a very virtual issue in EEG and ERP. Understanding the difference of various references will make the applications more confident. In this work, somatosensory evoked potential (SEP) with stimulation on the right hand was studied. The SEP spatio-temporal analysis was conducted comparatively on six references, left mastoid (contralateral mastoid reference, CM), right mastoid (ipsilateral mastoid reference, IM), linked mastoids (LM), average reference (AR), vertex reference (Cz) and the infinity reference (IR) newly proposed in 2001. Among the six, CM is the one used in actual recordings, and the other five are obtained by off-line re-referencing. The comparison is conducted on four selected components (P30 ms, P40 ms, N90 ms and P230 ms) in both temporal and spatial aspects. The results show that references may have a distinct influence on the amplitudes of the scalp potentials, with relative error at some electrodes larger than 500%, and for some electrodes it may even change the polarity. Pair-wise multiple comparison (Tukey test) shows that the differences of peak values among various references are very significant (P<0.001) between Cz and IR\\CM\\IM\\LM, and significant (P<0.01) between Cz and AR for component N90 ms; very significant (P<0.001) between Cz and IR\\CM\\IM\\LM\\AR, significant between IMLM and AR (P<0.01), CM and AR (P<0.05) for component P230 ms. The amplitude value order is CM/IM> or =LM>IR>AR>Cz. The two-ways (the six references vs. the four Peaks) repeated measures ANOVA test shows the effect of different references depends on various components; there is a statistically significant interaction between reference and the peak (P=<0.001). While for the spatial map of the potential amplitude, references will not affect the amplitude map shape if the color-bar is selected automatically, but if a fixed color-bar is chosen for data of various references, they may show some differences. These results mean a common reference is important for producing a comparable result between labs. As IR is theoretically a constant reference, we recommend it as the common choice in the future.
Final report on RMO Vickers key comparison COOMET M.H-K1
NASA Astrophysics Data System (ADS)
Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.
2013-01-01
This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Doughten, M.W.; Gillison, J.R.
1990-01-01
Methods for the determination of 24 elements in whole coal and coal ash by inductively coupled argon plasma-atomic emission spectrometry, flame, graphite furnace, and cold vapor atomic absorption spectrometry, and by ion-selective electrode are described. Coal ashes were analyzed in triplicate to determine the precision of the methods. Results of the analyses of NBS Standard Reference Materials 1633, 1633a, 1632a, and 1635 are reported. Accuracy of the methods is determined by comparison of the analysis of standard reference materials to their certified values as well as other values in the literature.
NASA Astrophysics Data System (ADS)
Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.
2009-01-01
A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Wack, Raymund F; Hansen, Eric; Small, Marilyn; Poppenga, Robert; Bunn, David; Johnson, Christine K
2012-04-01
Hematology and plasma biochemistry parameters are useful in the assessment and management of threatened and endangered species. Although reference ranges are readily available for many mammalian species, reference ranges for snakes are lacking for most species. We determined hematology and plasma biochemistry reference ranges for giant garter snakes (Thamnophis gigas) and valley garter snakes (Thamnophis sirtalis fitchi) living in four management areas in the Central Valley of California. White blood cell, heterophil, lymphocyte, and azurophil counts in giant garter snakes were approximately twice the values of valley garter snakes. Statistically significant differences in aspartate aminotransferase, globulin, and potassium between the two species did not appear clinically significant. No significant differences were found in the measured parameters between male and female giant garter snakes. Some differences were found among collection sites. These reference ranges provide baseline data for comparisons over time and between collection sites.
NASA Astrophysics Data System (ADS)
Rodrigo, F. S.; Gómez-Navarro, J. J.; Montávez Gómez, J. P.
2012-01-01
In this work, a reconstruction of climatic conditions in Andalusia (southern Iberian Peninsula) during the period 1701-1850, as well as an evaluation of its associated uncertainties, is presented. This period is interesting because it is characterized by a minimum in solar irradiance (Dalton Minimum, around 1800), as well as intense volcanic activity (for instance, the eruption of Tambora in 1815), at a time when any increase in atmospheric CO2 concentrations was of minor importance. The reconstruction is based on the analysis of a wide variety of documentary data. The reconstruction methodology is based on counting the number of extreme events in the past, and inferring mean value and standard deviation using the assumption of normal distribution for the seasonal means of climate variables. This reconstruction methodology is tested within the pseudoreality of a high-resolution paleoclimate simulation performed with the regional climate model MM5 coupled to the global model ECHO-G. The results show that the reconstructions are influenced by the reference period chosen and the threshold values used to define extreme values. This creates uncertainties which are assessed within the context of climate simulation. An ensemble of reconstructions was obtained using two different reference periods (1885-1915 and 1960-1990) and two pairs of percentiles as threshold values (10-90 and 25-75). The results correspond to winter temperature, and winter, spring and autumn rainfall, and they are compared with simulations of the climate model for the considered period. The mean value of winter temperature for the period 1781-1850 was 10.6 ± 0.1 °C (11.0 °C for the reference period 1960-1990). The mean value of winter rainfall for the period 1701-1850 was 267 ± 18 mm (224 mm for 1960-1990). The mean values of spring and autumn rainfall were 164 ± 11 and 194 ± 16 mm (129 and 162 mm for 1960-1990, respectively). Comparison of the distribution functions corresponding to 1790-1820 and 1960-1990 indicates that during the Dalton Minimum the frequency of dry and warm (wet and cold) winters was lower (higher) than during the reference period: temperatures were up to 0.5 °C lower than the 1960-1990 value, and rainfall was 4% higher.
COMPARISONS OF ACUTE REFERENCE VALUES IN DEVELOPING AN ACUTE INHALATION ASSESSMENT METHOD
A method is being developed for performing assessments of human health risk from acute (less than 24 hour) inhalation exposures. The methodology will be flexible in its ability to utilize variously robust data sets of dose-response information. A supporting task is a comparati...
Diemer, J; Quétel, C R; Taylor, P D P
2002-09-01
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Système International d'Unités). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low micro g kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high micro mol kg(-1) level), SI-traceable reference values with relative expanded uncertainties ( k=2) of less than 2 % were obtained.
Xi, Bo; Zong, Xin’nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M.; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y.T.; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K.; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Ben Romdhane, Habiba; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; Ati, Jalila El; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2015-01-01
Background Several distributions of country-specific blood pressure (BP) percentiles by sex, age and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limit international comparisons of prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents using seven nationally representative data (China, India, Iran, Korea, Poland, Tunisia and USA). Methods and Results Data on BP for 52,636 non-overweight children and adolescents aged 6–19 years were obtained from seven large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and USA. BP values were obtained with certified mercury sphygmomanometers in all seven countries, using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th and 99th) by age and height were estimated using the Generalized Additive Model for Location Scale and Shape (GAMLSS) model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. Compared to BP level of the 90th and 95th percentiles of the U.S. Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower while diastolic BP was similar. Conclusions These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help identify hypertensive youths in diverse populations. PMID:26671979
Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R
2014-05-15
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Husakova, T; Pavlata, L; Pechova, A; Hauptmanova, K; Pitropovska, E; Tichy, L
2014-09-01
The aim of this study was to establish reference interval for biochemical parameters in blood of alpacas on the basis of large population of clinically healthy animals, and to determine the influence of sex, age and season on nitrogen and lipid metabolites, enzymes, electrolytes, vitamins and minerals in blood of alpacas. Blood samples were collected from 311 alpacas (61 males and 201 females >6 months of age and 49 crias (21 males and 28 females) ⩽6 months of age). Selected farms were located in Central Europe (Czech Republic and Germany). We determined 24 biochemical parameters from blood serum. We performed the comparison of results by the sex of animals and for the older group also the comparison of the results with regard to the season, respectively, to the feeding period. We found no highly significant difference (P<0.01) between males and females with the exception of γ-glutamyl transferase (GGT), alkaline phosphatase (ALP) and cholesterol. We found 15 significantly different parameters between the group of crias 6 months of age and the older alpacas. Based on our findings we suggest for most parameters to use different reference intervals (especially ALP, cholesterol, total protein, globulin, non-esterified fatty acids (NEFA), GGT and phosphorus) for the two above-mentioned age groups. Another important finding is the differences between some parameters in older group of alpacas in summer/winter feeding period. Animals in the summer feeding period have higher values of parameters related to fat mobilization (β-hydroxybutyrate, NEFA) and liver metabolism (bilirubin, alanine aminotransferase). The winter period with increased feeding of supplements with higher amount of fat, vitamins and minerals is characteristic by increased values of cholesterol, triglycerides, vitamins A and E, and some minerals (K, Ca, Mg and Cl) in blood serum. Clinical laboratory diagnosis of metabolic disturbances may be improved with use of age-based reference values and with consideration of seasonal differences.
Sin, Della Wai-Mei; Wong, Yee-Lok; Cheng, Eddie Chung-Chin; Lo, Man-Fung; Ho, Clare; Mok, Chuen-Shing; Wong, Siu-Kay
2015-04-01
This paper presents the certification of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in a candidate tea certified reference material (code: GLHK-11-03) according to the requirements of the ISO Guide 30 series. Certification of GLHK-11-03 was based on an analytical method purposely developed for the accurate measurement of the mass fraction of the target analytes in the material. An isotope dilution mass spectrometry (IDMS) method involving determination by (i) gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) and (ii) gas chromatography-electron ionization-high-resolution mass spectrometry (GC-EI-HRMS) techniques was employed. The performance of the described method was demonstrated through participation in the key comparison CCQM-K95 "Mid-Polarity Analytes in Food Matrix: Mid-Polarity Pesticides in Tea" organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry in 2012, where the study material was the same as the certified reference material (CRM). The values reported by using the developed method were in good agreement with the key comparison reference value (KCRV) assigned for beta-endosulfan (727 ± 14 μg kg(-1)) and endosulfan sulfate (505 ± 11 μg kg(-1)), where the degree of equivalence (DoE) values were 0.41 and 0.40, respectively. The certified values of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in dry mass fraction in GLHK-11-03 were 350, 730, and 502 μg kg(-1), respectively, and the respective expanded uncertainties, due to sample inhomogeneity, long-term and short-term stability, and variability in the characterization procedure, were 27 μg kg(-1) (7.8 %), 48 μg kg(-1) (6.6 %), and 33 μg kg(-1) (6.6 %).
NASA Astrophysics Data System (ADS)
Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.
2011-12-01
The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.
Beaufrère, Hugues; Acierno, Mark; Mitchell, Mark; Guzman, David Sanchez-Migallon; Bryant, Heather; Tully, Thomas N
2011-06-01
Birds are routinely presented to veterinarians for dehydration. Success with these cases ultimately depends on providing replacement fluids and re-establishing fluid homeostasis. Few studies have been done to determine reference ranges for plasma osmolality in birds. The goals of this study were to determine reference values for plasma osmolality in 3 species of parrots and to provide recommendations on fluid selection for replacement therapy in these species. Blood samples were collected from 21 adult Hispaniolan Amazon parrots (Amazona ventralis), 21 Congo African grey parrots (Psittacus erithacus erithacus), and 9 red-fronted macaws (Ara rubrogenys), and were placed into lithium heparin containers. Plasma osmolality was measured in duplicate with a freezing point depression osmometer. Summary statistics were computed from the average values. Reference ranges, calculated by using the robust method, were 288-324, 308-345, and 223-369 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. The mean +/- SD values were 306 +/- 7, 327 +/- 7, and 304 +/- 18 mOsm/kg in African grey parrots, Hispaniolan Amazon parrots, and red-fronted macaws, respectively. Comparisons with osmolality values in mammals and values previously reported for psittacine bird species suggest that plasma osmolality is slightly higher in parrots than in mammals, species-specific differences exist, and differences between reported values occur. Overall, fluids with an osmolarity close to 300-320 mOsm/L, such as Normosol-R, Plasmalyte-R, Plasmalyte-A, and NaCl 0.9%, can be recommended in parrots for fluid replacement therapy when isotonic fluids are required.
NASA Astrophysics Data System (ADS)
Rodrigo, F. S.; Gómez-Navarro, J. J.; Montávez Gómez, J. P.
2011-07-01
In this work, a reconstruction of climatic conditions in Andalusia (southern Iberia Peninsula) during the period 1701-1850, as well as an evaluation of its associated uncertainties, is presented. This period is interesting because it is characterized by a minimum in the solar irradiance (Dalton Minimum, around 1800), as well as intense volcanic activity (for instance, the eruption of the Tambora in 1815), when the increasing atmospheric CO2 concentrations were of minor importance. The reconstruction is based on the analysis of a wide variety of documentary data. The reconstruction methodology is based on accounting the number of extreme events in past, and inferring mean value and standard deviation using the assumption of normal distribution for the seasonal means of climate variables. This reconstruction methodology is tested within the pseudoreality of a high-resolution paleoclimate simulation performed with the regional climate model MM5 coupled to the global model ECHO-G. Results show that the reconstructions are influenced by the reference period chosen and the threshold values used to define extreme values. This creates uncertainties which are assesed within the context of the climate simulation. An ensemble of reconstructions was obtained using two different reference periods and two pairs of percentiles as threshold values. Results correspond to winter temperature, and winter, spring, and autumn rainfall, and they are compared with simulations of the climate model for the considered period. The comparison of the distribution functions corresponding to 1790-1820 and 1960-1990 periods indicates that during the Dalton Minimum the frequency of dry and warm (wet and cold) winters was lesser (higher) than during the reference period. In spring and autumn it was detected an increase (decrease) in the frequency of wet (dry) seasons. Future research challenges are outlined.
Notes on numerical reliability of several statistical analysis programs
Landwehr, J.M.; Tasker, Gary D.
1999-01-01
This report presents a benchmark analysis of several statistical analysis programs currently in use in the USGS. The benchmark consists of a comparison between the values provided by a statistical analysis program for variables in the reference data set ANASTY and their known or calculated theoretical values. The ANASTY data set is an amendment of the Wilkinson NASTY data set that has been used in the statistical literature to assess the reliability (computational correctness) of calculated analytical results.
Hrubec, Terry C.; Smith, Stephen A.; Robertson, John L.
2001-01-01
Hybrid striped bass (Morone chrysops X Morone saxatilis ) are an important aquaculture species yet there are few diagnostic tools available to assess their health. Hematology and clinical chemistry analyses are not used extensively in fish medicine due to the lack of reference intervals for various fish species, and because factors such as age can affect blood values. There is little published information regarding age-related changes in blood values of juvenile fish. It is important to evaluate juvenile fish, as this is the time they are raised in aquaculture settings. Determining age-related changes in the blood values of fishes would further develop clinical pathology as a diagnostic tool, enhancing both fish medicine and the aquaculture industry. The results of standard hematology and clinical chemistry analysis were evaluated in juvenile hybrid striped bass at 4, 6, 9, 15, and 19 months of age. Values for PCV and RBC indices were significantly lower, and plasma protein concentration was significantly higher in younger fish. Total WBC and lymphocyte counts were significantly higher in fish at 6 and 9 months of age, while neutrophil and monocyte counts were higher at 6, 9, and 15 months. Eosinophil counts were significantly higher in 9-month-old fish. The majority of hematologic values fell within previously established reference intervals, indicating that only slight modification to the intervals is necessary for evaluating hematologic results of hybrid striped bass at different ages. The following analytes deviated sufficiently from adult reference intervals to warrant separate reference values: plasma protein concentration at 4 months, WBC and lymphocyte counts at 15 and 19 months, and thrombocyte-like-cells at 9 months of age. Values for most biochemical analytes were significantly different among age groups except for creatinine and potassium concentrations. Comparisons with reference intervals were not made for biochemical analytes, because established reference intervals were not available. Age-related changes in hematologic and biochemical values of striped bass were similar to those reported for rainbow trout and mammals.
Energy Index For Aircraft Maneuvers
NASA Technical Reports Server (NTRS)
Chidester, Thomas R. (Inventor); Lynch, Robert E. (Inventor); Lawrence, Robert E. (Inventor); Amidan, Brett G. (Inventor); Ferryman, Thomas A. (Inventor); Drew, Douglas A. (Inventor); Ainsworth, Robert J. (Inventor); Prothero, Gary L. (Inventor); Romanowski, Tomothy P. (Inventor); Bloch, Laurent (Inventor)
2006-01-01
Method and system for analyzing, separately or in combination, kinetic energy and potential energy and/or their time derivatives, measured or estimated or computed, for an aircraft in approach phase or in takeoff phase, to determine if the aircraft is or will be put in an anomalous configuration in order to join a stable approach path or takeoff path. A 3 reference value of kinetic energy andor potential energy (or time derivatives thereof) is provided, and a comparison index .for the estimated energy and reference energy is computed and compared with a normal range of index values for a corresponding aircraft maneuver. If the computed energy index lies outside the normal index range, this phase of the aircraft is identified as anomalous, non-normal or potentially unstable.
Coherent Anti-stokes Raman Spectroscopy (CARS) of gun propellant flames
NASA Technical Reports Server (NTRS)
Mcilwain, M. E.; Harris, L. E.
1980-01-01
Temperature measurements were made in a slightly fuel rich, premixed propane/air reference flame and nitrate ester propellant flames burning in air at atmospheric pressure using coherent anti-stokes raman scattering (CARS). Both single and multiple pulse VARS spectra of nitrogen in the reference flame were in good agreement with calculated and reported values. Single pulse CARS nitrogen spectra obtained in the propellant flames were analyzed to give temperatures consistent with values calculated using the NASA-Lewis thermochemical calculation. Comparison of a 0.1 second separated sequence of single pulse CARS spectra indicate turbulent air mixing in these propellant flames. The CARS spectral results demonstrate that temporal and spatially resolved temperature measurements could be determined in transient, turbulent flames.
Mathematics Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Fraser, Graham, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from previous tests are made available to teachers for the construction of pretests or posttests, reference tests for inter-class comparisons and general assignments. The collection was reviewed for content…
Occupational health standards. An international comparison.
Holmberg, B; Winell, M
1977-03-01
The background for establishing standards for toxic agents is reviewed, and the standards of 14 different countries, including Sweden, are compared with special reference to criteria and organizational aspects. The differences among countries in the numerical limit values for toxic substances are largely due to differences in definitions, biomedical criteria, technical feasibility and sociopolitical judgements.
NASA Astrophysics Data System (ADS)
Mautjana, R. T.; Molefe, P. T.; Mayindu, N. F.; Armah, M. N.; Ramasawmy, V.; Albasini, G. L.; Matali, S.; Richmond, H.; Rusimbi, V.; Kiwanuka, J.; Mutale, D. M.; Mutsimba, F.
2018-01-01
This report summarizes the results of AFRIMETS.M.M-S6 mass standards comparison conducted between eleven participating laboratories/countries. Two sets of five weights with nominal values 100 mg, 100 g, 500 g, 1 kg and 5 kg were used as the traveling standards. These nominal values were decided from the needs of participating laboratories submitted to the pilot laboratory through a questionnaire and agreed upon by all participants. The traveling standards were hand carried between laboratories starting from February 2014 and were received from the last participants in October 2014. The programme was coordinated by National Metrology Institute of South Africa (NMISA), who provided the travelling standards and reference values for the comparison. The corrections to the BIPM as-maintained mass unit [5] have insignificant influence on the results of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong
2013-01-01
Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Anomaly-specified virtual dimensionality
NASA Astrophysics Data System (ADS)
Chen, Shih-Yu; Paylor, Drew; Chang, Chein-I.
2013-09-01
Virtual dimensionality (VD) has received considerable interest where VD is used to estimate the number of spectral distinct signatures, denoted by p. Unfortunately, no specific definition is provided by VD for what a spectrally distinct signature is. As a result, various types of spectral distinct signatures determine different values of VD. There is no one value-fit-all for VD. In order to address this issue this paper presents a new concept, referred to as anomaly-specified VD (AS-VD) which determines the number of anomalies of interest present in the data. Specifically, two types of anomaly detection algorithms are of particular interest, sample covariance matrix K-based anomaly detector developed by Reed and Yu, referred to as K-RXD and sample correlation matrix R-based RXD, referred to as R-RXD. Since K-RXD is only determined by 2nd order statistics compared to R-RXD which is specified by statistics of the first two orders including sample mean as the first order statistics, the values determined by K-RXD and R-RXD will be different. Experiments are conducted in comparison with widely used eigen-based approaches.
Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier
2018-02-01
The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.
Seguel, Mauricio; Muñoz, Francisco; Keenan, Alessandra; Perez-Venegas, Diego J; DeRango, Eugene; Paves, Hector; Gottdenker, Nicole; Müller, Ananda
2016-07-01
The establishment of clinical pathology baseline data is critical to evaluate temporal and spatial changes in marine mammal groups. Despite increased availability of studies on hematology and biochemistry of marine mammals, reference ranges are lacking for many populations, especially among fur seal species. During the austral summers of 2014 and 2015, we evaluated basic hematologic and biochemical parameters in clinically healthy, physically restrained South American fur seal ( Arctocephalus australis ) lactating females and 2-mo-old pups. We also assessed the temporal variation of hematology parameters on the pups during their first 2 mo of life. Reference ranges of lactating females were similar to those previously reported in other fur seal species. In the case of pups, reference ranges are similar to values previously reported in sea lion species. As expected, most biochemical and hematologic values differ significantly between adult females and pups. As in other otariids, South American fur seals pups are born with higher values of total red blood cells, hemoglobin, and packed cell volume, and lower numbers of total leukocytes, neutrophils, lymphocytes, and eosinophils. To the best of our knowledge, data on hematology reference values for South American fur seals has not been previously reported and is useful for continued health monitoring of this species, as well as for comparisons with other otariid groups.
[Features of the lipid exchange in workers employed in aluminium productions].
Kudaeva, I V; Dyakovich, O A; Masnavieva, L B; Popkova, O V; Abramatets, E A
Aluminum production can be referred to the category of industries of the increased health hazard for the workers. During technological process of receiving aluminum the air of a working zone is polluted by a large number of harmful substances. Workers are exposed to the complex of toxicants possessing a polytropic impact on the body. The most significant consequences are violations of different types of metabolism in the organism, including lipid metabolism. The purpose of the study is the investigation of the state of lipid metabolism in persons working in the production of aluminum. The object of research was 108 male workers of aluminum production suffering from occupational pathology of airways. The group of comparison was consisted of 103 men, apparently healthy, not exposed to toxicants. There was determined the content of the total cholesterol (TC), high and low density lipoprotein cholesterol (HDLC and LDLC), triglycerides (TG), phospholipids (PL), atherogenic index (AI). Statistical processing was performed with the use of software «Statistica 6.0». There were established statistically significant differences of indices of lipid exchange in the persons occupied in aluminum production when related to the group of comparison. IA values in persons from the study group proved to be higher than in the comparison group, due to elevated levels of TC and LDLC. The TG and PL level was also higher. The values of IA, TC and TG in workers of aluminum production in more than 50% cases exceeded the reference values. The average concentration of HDL cholesterol in both groups did not differ, and was above the lower reference boundary. Established features of lipid metabolism in workers of aluminum allow us to suggest the distinction in mechanisms of developing proatherogenic disorders from previously established ones for workers exposed to other chemicals. One of the causes of the shaping of these disorders can be oxidative stress, which in turn serves as a response to the exposure of complex of toxic substances to workers.
[South American camelids in Switzerland. II. Reference values for blood parameters].
Hengrave Burri, I; Tschudi, P; Martig, J; Liesegang, A; Meylan, M
2005-08-01
In order to establish reference values for blood parameters of South American camelids in Switzerland, 273 blood samples were collected from 141 llamas and 132 alpacas. These animals were classified in three categories (young animals < six months, adult females and males). Forty-one parameters were measured (red blood cell count, white blood cell count, electrolytes, metabolites and enzymes). Significant differences between llamas and alpacas were evident for 26 parameters. This study also showed that differences between young animals, females and males must be taken into consideration. A comparison of blood values with the results of fecal analysis for parasite eggs showed that an infestation with Dicrocoelium dendriticum was associated with elevated activity of two liver enzymes (GLDH and gamma-GT) in the serum. In contrast, no differences were found in the results of blood analyses between animals shedding eggs of gastrointestinal strongyles or not.
Hot and cold body reference noise generators from 0 to 40 GHz
NASA Technical Reports Server (NTRS)
Hornbostel, D. H.
1974-01-01
This article describes the design, development, and analysis of exceptionally accurate radiometric noise generators from 0-40 GHz to serve as standard references. Size, weight, power, and reliability are optimized to meet the requirements of NASA air- and space-borne radiometers. The radiometric noise temperature of these noise generators is, unavoidably, calculated from measured values rather than measured directly. The absolute accuracy and stability are equal to or better than those of reliable standards available for comparison. A noise generator has been developed whose measurable properties (VSWR, line loss, thermometric temperatures) have been optimized in order to minimize the effects of the uncertainty in the calculated radiometric noise temperatures. Each measurable property is evaluated and analyzed to determine the effects of the uncertainty of the measured value. Unmeasurable properties (primarily temperature gradients) are analyzed, and reasonable precautions are designed into the noise generator to guarantee that the uncertainty of the value remains within tolerable limits.
Ortiz, Roderick F.; Ferguson, Sheryl A.
2001-01-01
A comprehensive water-quality sampling network was implemented by the U.S. Geological Survey from 1995 through 1997 at 12 tributary sites to the Alamosa River. The network was designed to address data gaps identified in the initial ecological risk assessment of the Summitville Superfund site. Tributaries draining hydrothermally altered areas had higher median values for nearly all measured properties and constituents than tributaries draining unaltered areas. Colorado instream standards for pH, copper, iron, and zinc were in attainment at most tributary sites. Instream standards for pH and chronic aquatic-life standards for iron were not attained in Jasper Creek. Toxicological reference values were most often exceeded at Iron Creek, Alum Creek, Bitter Creek, Wightman Fork, and Burnt Creek. These tributaries all drain hydrothermally altered areas.
NASA Astrophysics Data System (ADS)
Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin
2014-01-01
This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
The effect of geographical indices on left ventricular structure in healthy Han Chinese population
NASA Astrophysics Data System (ADS)
Cen, Minyi; Ge, Miao; Liu, Yonglin; Wang, Congxia; Yang, Shaofang
2017-02-01
The left ventricular posterior wall thickness (LVPWT) and interventricular septum thickness (IVST) are generally regarded as the functional parts of the left ventricular (LV) structure. This paper aims to examine the effects of geographical indices on healthy Han adults' LV structural indices and to offer a scientific basis for developing a unified standard for the reference values of adults' LV structural indices in China. Fifteen terrain, climate, and soil indices were examined as geographical explanatory variables. Statistical analysis was performed using correlation analysis. Moreover, a back propagation neural network (BPNN) and a support vector regression (SVR) were applied to developing models to predict the values of two indices. After the prediction models were built, distribution maps were produced. The results show that LV structural indices are characteristically associated with latitude, longitude, altitude, average temperature, average wind velocity, topsoil sand fraction, topsoil silt fraction, topsoil organic carbon, and topsoil sodicity. The model test analyses show the BPNN model possesses better simulative and predictive ability in comparison with the SVR model. The distribution maps of the LV structural indices show that, in China, the values are higher in the west and lower in the east. These results demonstrate that the reference values of the adults' LV structural indices will be different affected by different geographical environment. The reference values of LV structural indices in one region can be calculated by setting up a BPNN, which showed better applicability in this study. The distribution of the reference values of the LV structural indices can be seen clearly on the geographical distribution map.
The effect of geographical indices on left ventricular structure in healthy Han Chinese population.
Cen, Minyi; Ge, Miao; Liu, Yonglin; Wang, Congxia; Yang, Shaofang
2017-02-01
The left ventricular posterior wall thickness (LVPWT) and interventricular septum thickness (IVST) are generally regarded as the functional parts of the left ventricular (LV) structure. This paper aims to examine the effects of geographical indices on healthy Han adults' LV structural indices and to offer a scientific basis for developing a unified standard for the reference values of adults' LV structural indices in China. Fifteen terrain, climate, and soil indices were examined as geographical explanatory variables. Statistical analysis was performed using correlation analysis. Moreover, a back propagation neural network (BPNN) and a support vector regression (SVR) were applied to developing models to predict the values of two indices. After the prediction models were built, distribution maps were produced. The results show that LV structural indices are characteristically associated with latitude, longitude, altitude, average temperature, average wind velocity, topsoil sand fraction, topsoil silt fraction, topsoil organic carbon, and topsoil sodicity. The model test analyses show the BPNN model possesses better simulative and predictive ability in comparison with the SVR model. The distribution maps of the LV structural indices show that, in China, the values are higher in the west and lower in the east. These results demonstrate that the reference values of the adults' LV structural indices will be different affected by different geographical environment. The reference values of LV structural indices in one region can be calculated by setting up a BPNN, which showed better applicability in this study. The distribution of the reference values of the LV structural indices can be seen clearly on the geographical distribution map.
NASA Technical Reports Server (NTRS)
Juang, Jer-Nan; Kim, Hye-Young; Junkins, John L.
2003-01-01
A new star pattern recognition method is developed using singular value decomposition of a measured unit column vector matrix in a measurement frame and the corresponding cataloged vector matrix in a reference frame. It is shown that singular values and right singular vectors are invariant with respect to coordinate transformation and robust under uncertainty. One advantage of singular value comparison is that a pairing process for individual measured and cataloged stars is not necessary, and the attitude estimation and pattern recognition process are not separated. An associated method for mission catalog design is introduced and simulation results are presented.
An Analysis of a Ray Trace Experiment on the Underwater Range at Dabob Bay
1975-03-01
with a local oscil- lator havIng a frequency unique to that hyIrophone. ’The outputs of these oscillators are preamplified and fed to a multiplexer...conmpared with a Eeist value given by the reference gradient plus a designated change from 5 to 30%. When the computed gradient exceeds the test value...mid profile was also performed. This comparison was designed to show the effects of using a single profile to describe the environment when the actual
1000 Norms Project: protocol of a cross-sectional study cataloging human variation.
McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Hiller, Claire E; Nightingale, Elizabeth J; Moloney, Niamh A; Quinlan, Kate G; Pourkazemi, Fereshteh; Sman, Amy D; Nicholson, Leslie L; Mousavi, Seyed J; Rose, Kristy; Raymond, Jacqueline; Mackey, Martin G; Chard, Angus; Hübscher, Markus; Wegener, Caleb; Fong Yan, Alycia; Refshauge, Kathryn M; Burns, Joshua
2016-03-01
Clinical decision-making regarding diagnosis and management largely depends on comparison with healthy or 'normal' values. Physiotherapists and researchers therefore need access to robust patient-centred outcome measures and appropriate reference values. However there is a lack of high-quality reference data for many clinical measures. The aim of the 1000 Norms Project is to generate a freely accessible database of musculoskeletal and neurological reference values representative of the healthy population across the lifespan. In 2012 the 1000 Norms Project Consortium defined the concept of 'normal', established a sampling strategy and selected measures based on clinical significance, psychometric properties and the need for reference data. Musculoskeletal and neurological items tapping the constructs of dexterity, balance, ambulation, joint range of motion, strength and power, endurance and motor planning will be collected in this cross-sectional study. Standardised questionnaires will evaluate quality of life, physical activity, and musculoskeletal health. Saliva DNA will be analysed for the ACTN3 genotype ('gene for speed'). A volunteer cohort of 1000 participants aged 3 to 100 years will be recruited according to a set of self-reported health criteria. Descriptive statistics will be generated, creating tables of mean values and standard deviations stratified for age and gender. Quantile regression equations will be used to generate age charts and age-specific centile values. This project will be a powerful resource to assist physiotherapists and clinicians across all areas of healthcare to diagnose pathology, track disease progression and evaluate treatment response. This reference dataset will also contribute to the development of robust patient-centred clinical trial outcome measures. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Radiation detector device for rejecting and excluding incomplete charge collection events
Bolotnikov, Aleksey E.; De Geronimo, Gianluigi; Vernon, Emerson; Yang, Ge; Camarda, Giuseppe; Cui, Yonggang; Hossain, Anwar; Kim, Ki Hyun; James, Ralph B.
2016-05-10
A radiation detector device is provided that is capable of distinguishing between full charge collection (FCC) events and incomplete charge collection (ICC) events based upon a correlation value comparison algorithm that compares correlation values calculated for individually sensed radiation detection events with a calibrated FCC event correlation function. The calibrated FCC event correlation function serves as a reference curve utilized by a correlation value comparison algorithm to determine whether a sensed radiation detection event fits the profile of the FCC event correlation function within the noise tolerances of the radiation detector device. If the radiation detection event is determined to be an ICC event, then the spectrum for the ICC event is rejected and excluded from inclusion in the radiation detector device spectral analyses. The radiation detector device also can calculate a performance factor to determine the efficacy of distinguishing between FCC and ICC events.
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K
2017-04-01
The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
A Comparative Study of Location-sharing Privacy Preferences in the U.S. and China
2012-01-01
Key words: Location Sharing, Cross- cultural Comparison, Location Privacy 3 ABSTRACT...1 By “ cultural factors”, we mean to refer to a broad range of considerations, including beliefs, moral values...different in the U.S. and China. We acknowledge that fully understanding how culture influences location privacy will require a long-term
Soulakova, Julia N; Bright, Brianna C
2013-01-01
A large-sample problem of illustrating noninferiority of an experimental treatment over a referent treatment for binary outcomes is considered. The methods of illustrating noninferiority involve constructing the lower two-sided confidence bound for the difference between binomial proportions corresponding to the experimental and referent treatments and comparing it with the negative value of the noninferiority margin. The three considered methods, Anbar, Falk-Koch, and Reduced Falk-Koch, handle the comparison in an asymmetric way, that is, only the referent proportion out of the two, experimental and referent, is directly involved in the expression for the variance of the difference between two sample proportions. Five continuity corrections (including zero) are considered with respect to each approach. The key properties of the corresponding methods are evaluated via simulations. First, the uncorrected two-sided confidence intervals can, potentially, have smaller coverage probability than the nominal level even for moderately large sample sizes, for example, 150 per group. Next, the 15 testing methods are discussed in terms of their Type I error rate and power. In the settings with a relatively small referent proportion (about 0.4 or smaller), the Anbar approach with Yates' continuity correction is recommended for balanced designs and the Falk-Koch method with Yates' correction is recommended for unbalanced designs. For relatively moderate (about 0.6) and large (about 0.8 or greater) referent proportion, the uncorrected Reduced Falk-Koch method is recommended, although in this case, all methods tend to be over-conservative. These results are expected to be used in the design stage of a noninferiority study when asymmetric comparisons are envisioned. Copyright © 2013 John Wiley & Sons, Ltd.
Straub, Jens; Valerius, Klaus-Peter; Pees, Michael; Krautwald-Junghanns, Maria-Elisabeth
2002-01-01
Due to lack of reference values an objective assessment of myocardial dilatation and hypertrophy in cage and aviary birds so far is not possible. Therefore the thickness of the myocardium of the left and the right ventricle of the heart of 14 budgerigars (Melopsittacus undulatus) and 5 Alisterus parrots (Alisterus s. scapularis) of both sexes was examined according to a standard protocol to establish morphometric data and first reference values. In order to compare the results of birds of different sizes all data were set in relation to the size of the bird's body (length of the sternum). Results of different zones were compared by means of statistical methods within one species. Besides that a comparison between the two species was performed. Only minor significant differences could be noticed.
International comparison Euramet.QM-K111—propane in nitrogen
NASA Astrophysics Data System (ADS)
Wouter van der Hout, J.; van der Veen, Adriaan M. H.; Ziel, Paul R.; Kipphardt, Heinrich; Tuma, Dirk; Maiwald, Michael; Fernández, Teresa E.; Gómez, Concepción; Cieciora, Dariusz; Ochman, Grzegorz; Dias, Florbela; Silvino, Victor; Macé, Tatiana; Sutour, Christophe; Marioni, Fabrice; Ackermann, Andreas; Niederhauser, Bernhard; Fükő, Judit; Büki, Tamás; Nagyné Szilágyi, Zsófia; Tarhan, Tanıl; Engin, Erinç
2017-01-01
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within +/- 1 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.
2009-01-01
In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa
Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina
2017-01-01
The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. PMID:28216793
Qureshi, Waqas T.; Leigh, J. Adam; Swett, Katrina; Ajay, Dharod; Allison, Matthew A.; Cai, Jianwen; Gonzalez, Franklyn; Hurwitz, Barry E.; Shah, Sanjiv J.; Desai, Ankit A.; Spevack, Daniel M.; Rodriguez, Carlos J.
2015-01-01
Background Reference limits for echocardiographic quantification of cardiac chambers in Hispanics are not well studied. Methods and Results We examined the reference values of left atrium (LA) and ventricle (LV) structure in a large ethnically diverse Hispanic cohort. Two-dimensional transthoracic echocardiography was performed in 1,818 participants of the Echocardiographic Study of Latinos (ECHO-SOL). Individuals with body mass index ≥30kg/m2, hypertension, diabetes mellitus, coronary artery disease and atrial fibrillation were excluded leaving 525 participants defined as healthy reference-cohort. We estimated 95th weighted percentiles of LV end systolic volume, LV end diastolic volume, relative wall and septal thickness, LV mass and left atrial volume. We then used upper reference limits of the 2005 and 2015 American Society of Echocardiography (ASE) and 95th percentile of reference cohort to classify the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) target population into abnormal and normal. Reference limits were also calculated for each of 6 Hispanic origins. Using ASE 2015 defined reference values we categorized 7%, 21%, 57% and 17% of males and 18%, 29%, 60% and 26% of females as having abnormal LV mass index, relative, septal and posterior wall thickness, respectively. Conversely, 10%, and 11% of males and 4% and 2% of females were classified as having abnormal end-diastolic volume and internal diameter by ASE 2015 cut-offs, respectively. Similar differences were found when we used 2005 ASE cut offs. Several differences were noted in distribution of cardiac structure and volumes among various Hispanic/Latino origins. Cubans had highest values of echocardiographic measures and Central Americans had the lowest. Conclusions This is the first large study that provides normal reference values for cardiac structure. It further demonstrates that a considerable segment of Hispanic/Latinos residing in US may be classified as having abnormal measures of cardiac chambers when 2015 and 2005 ASE reference cut-offs are used. PMID:26712159
Radiopacity Evaluation of Gutta-Percha Points in Thinner Samples than the ANSI/ADA Recommendation.
Petry, Bruna Lucian; Bodanezi, Augusto; Baldasso, Flávia Emi Razera; Delai, Débora; Larentis, Naiara Leites; Fontanella, Vania Regina Camargo; Kopper, Patrícia Maria Poli
2017-01-01
The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).
Reference values of hip abductor torque among youth athletes: Influence of age, sex and sports.
Bittencourt, Natália Franco Netto; Santos, Thiago Ribeiro Teles; Gonçalves, Gabriela Gomes Pavan; Coelho, Amanda Priscila; Gomes, Bárbara Gonçalves Braz de Magalhães; Mendonça, Luciana De Michelis; Fonseca, Sérgio Teixeira
2016-09-01
(1) To determine the reference values of hip abductor torque in youth athletes; (2) To investigate the influence of sex, age and sports on hip abductors torque. Cross-sectional. Sports clubs. 301 volleyball, basketball and futsal athletes between 10 and 19 years of age. Mean value of three maximal isometric hip abductor torques, evaluated using a hand-held dynamometer. The mean values of maximal isometric hip abductor torque ranged from 1.03 to 1.50 Nm/kg. The dominant hip abductor torque values were greater in 15-19 years old (1.41 ± 0.27 Nm/kg) than in 10-14 years old (1.12 ± 0.31 Nm/kg). In addition, the hip abductor torque values were smaller in basketball players (1.15 ± 0.31 Nm/kg) than futsal (1.34 ± 0.37 Nm/kg) and volleyball players (1.28 ± 0.25 Nm/kg). The comparison of hip abductor torque between futsal and volleyball players revealed no difference. The hip abductor torque values were greater in male volleyball athletes (1.28 ± 0.25 Nm/kg) than female volleyball athletes (1.13 ± 0.22 Nm/kg). This study established reference values for maximal isometric hip abductor torque in youth volleyball, basketball and futsal athletes. In addition, the results demonstrated that sex, age and sports influenced hip abductor torque. Copyright © 2015 Elsevier Ltd. All rights reserved.
Results of the supplementary comparison SIM.M.FF-S12 for volume of liquids at 20 L
NASA Astrophysics Data System (ADS)
Maldonado, M.; Castillo, E.; Rodríguez, L. D.
2018-01-01
A supplementary comparison was performed in order to compare national measurement systems to determine volume of liquids, particularly at fixed volume of 20 L. The participants were CENAM (Mexico), LACOMET (Costa Rica) and RECOPE (Costa Rica). The measurements were carried out from October 2016 to June 2017. The chosen value of volume (20 L) is representative of the Calibration and Measurement Capabilities (CMCs) declared by the three participants. The transfer standard (TS) was a stainless steel pipette for volume at 20 L. Prior to the beginning of the comparison, the TS was tested by CENAM. The results of the test phase showed excellent values for both repeatability and reproducibility. During the SIM.M.FF-S12, the results of the laboratories showed good agreement with the reference values. The best estimation of the measurands, as reported by the participants, showed a +/- 0.0022 % as the largest difference among the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
On the theory of behavioral mechanics.
Dzendolet, E
1999-12-01
The Theory of Behavioral Mechanics is the behavioral analogue of Newton's laws of motion, with the rate of responding in operant conditioning corresponding to physical velocity. In an earlier work, the basic relation between rate of responding and sessions under two FI schedules and over a range of commonly used session values had been shown to be a power function. Using that basic relation, functions for behavioral acceleration, mass, and momentum are derived here. Data from other laboratories also support the applicability of a power function to VI schedules. A particular numerical value is introduced here to be the standard reference value for the behavioral force under the VI-60-s schedule. This reference allows numerical values to be calculated for the behavioral mass and momentum of individual animals. A comparison of the numerical values of the momenta of two animals can be used to evaluate their relative resistances to change, e.g., to extinction, which is itself viewed as a continuously changing behavioral force being imposed on the animal. This overall numerical approach allows behavioral force-values to be assigned to various experimental conditions such as the evaluation of the behavioral force of a medication dosage.
Wu, Liejun; Chen, Maoxue; Chen, Yongli; Li, Qing X.
2013-01-01
Gas holdup time (tM) is a basic parameter in isothermal gas chromatography (GC). Determination and evaluation of tM and retention behaviors of n-alkanes under isothermal GC conditions have been extensively studied since the 1950s, but still remains unresolved. The difference equation (DE) model [J. Chromatogr. A 1260:215–223] reveals retention behaviors of n-alkanes excluding tM, while the quadratic equation (QE) model [J. Chromatogr. A 1260:224–231] including tM is suitable for applications. In the present study, tM values were calculated with the QE model, which is referred to as tMT, evaluated and compared with other three typical nonlinear models. The QE model gives an accurate estimation of tM in isothermal GC. The tMT values are highly accurate, stable, and easy to calculate and use. There is only one tMT value at each GC condition. The proper classification of tM values can clarify their disagreement and facilitate GC retention data standardization for which tMT values are promising reference tM values. PMID:23726077
[Clinical value evaluation of Chinese herbal formula in context of multi-omics network].
Li, Bing; Han, Fei; Wang, Zhong; Wang, Yong-Yan
2017-03-01
Clinical value evaluation is the key issue to solve the problems such as high repetition rate, fuzzy clinical positioning, broad indications and unclear clinical values in Chinese herbal formula(Chinese patent medicine). By analyzing the challenges and opportunities of Chinese herbal formula in clinical value evaluation, this paper introduced a strategy of multi-omic network analysis. Through comparative analysis of three stroke treatment formulas, we suggested their different characteristic advantages for variant symptoms or phenotypes of stroke, which may provide reference for rational clinical choice. Such multi-omic network analysis strategy may open a unique angle of view for clinical evaluation and comparison of Chinese herbal formula. Copyright© by the Chinese Pharmaceutical Association.
Ionospheric foF2 at EIA region: comparison between observations and IRI model
NASA Astrophysics Data System (ADS)
Chuo, Y. J.; Lee, C. C.
We have used data from an equatorial ionization anomaly area station in the western Pacific region to study the monthly variability of foF2 Diurnal seasonal and solar activity effects were investigated The data established by this study are proposed as valid input values for the development of URSI and CCIR options for the International Reference Ionosphere
Comparison of δ18O measurements in nitrate by different combustion techniques
Revesz, Kinga; Böhlke, John Karl
2002-01-01
Three different KNO3 salts with δ18O values ranging from about −31 to +54‰ relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with δ18O values in the midpoint of the δ18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25‰). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the δ18O scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with δ18O values far from that of atmospheric O2, to improve interlaboratory comparability.
Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.
Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T
2017-12-01
The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.
NASA Technical Reports Server (NTRS)
Hastings, E. C., Jr.; Shanks, R. E.; Mueller, A. W.
1976-01-01
Noise measurements have been made with a twin-engine commercial jet aircraft making 3 deg approaches and level flyovers. The flight-test data showed that, in the standard 3 deg approach configuration with 40 deg flaps, effective perceived noise level (EPNL) had a value of 109.5 effective perceived noise decibels (EPNdB). This result was in agreement with unpublished data obtained with the same type of aircraft during noise certification tests; the 3 deg approaches made with 30 deg flaps and slightly reduced thrust reduced the EPNL value by 1 EPNdB. Extended center-line noise determined during the 3 deg approaches with 40 deg flaps showed that the maximum reference A-weighted sound pressure level (LA,max)ref varied from 100.0 A-weighted decibels 2.01 km (108 n. mi.) from the threshold to 87.4 db(A) at 6.12 km (3.30 n. mi.) from the threshold. These test values were about 3 db(A) higher than estimates used for comparison. The test data along the extended center line during approaches with 30 deg flaps were 1 db(A) lower than those for approaches with 40 deg flaps. Flight-test data correlating (LA,max)ref with thrust at altitudes of 122 m (400 ft) and 610 m (2000 ft) were in agreement with reference data used for comparison.
Pratt, Kenneth W
2015-04-01
This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).
KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine
NASA Astrophysics Data System (ADS)
Liu, Fong-Ha; Mackay, Lindsey; Murby, John
2010-01-01
The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
NASA Astrophysics Data System (ADS)
Wuethrich, C.; Alisic, S.; Altintas, A.; van Andel, I.; C, InMook; Eltawil, A. A.; Farár, P.; Hetherington, P.; Koçaş, I.; Lefkopoulos, A.; Otal, P.; Prazak, D.; Sabuga, W.; Salustiano, R.; Sandu, I.; Sardi, M.; Saxholm, S.; Setina, J.; Spohr, I.; Steindl, D.; Testa, N.; Vámossy, C.; Grgec Bermanec, L.
2016-01-01
It was decided at the EURAMET TC-M meeting in Torino in 2006 to realize a comparison in gauge and absolute pressure up to 200 kPa as it would allow a link to the CCM.P-K6 and CCM.P-K2 comparisons to be established. This project interested a lot of laboratories from the beginning with 23 participants, 22 of which have submitted results. The circulation of the transfer standard began in July 2009 and lasted until January 2012. No major problems occurred during the transport. The measurand of the comparison is the effective area of a piston-cylinder determined in gauge and absolute pressure from 25 kPa to 200 kPa with pressure steps of 25 kPa. The transfer standard is a gas lubricated tungsten carbide piston-cylinder with an effective area of ~9.8 cm2, fabricated by DH Instruments and compatible with a PG-7601 pressure balance. Some participants used their own pressure balance while a pressure balance with a reference vacuum sensor has been circulated for the participants not equipped with this system. One participant (SMU, Slovakia) has never provided the measurement results and another participant (FORCE Technology, Denmark) submitted a revised set of measurement results after the pilot laboratory mentioned that the equivalence was not met. After the determination of the reference value, all the 22 participants who delivered the results in gauge pressure demonstrated equivalence respective to the reference value on most of the range. In absolute pressure the equivalence is demonstrated, for all nominal pressures, by all 17 participants who submitted results. The comparison is linked to the CCM.P-K6 for gauge pressure and to CCM.P-K2 for absolute pressure. The link does not strongly affect the equivalence of the results and an excellent degree of equivalence is achieved in gauge and absolute pressure. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Heine, Henry S.; England, Marilyn J.; Waag, David M.; Byrne, W. Russell
2001-01-01
In vitro susceptibilities to 28 antibiotics were determined for 11 strains of Burkholderia mallei by the broth microdilution method. The B. mallei strains demonstrated susceptibility to aminoglycosides, macrolides, quinolones, doxycycline, piperacillin, ceftazidime, and imipenem. For comparison and evaluation, 17 antibiotic susceptibilities were also determined by the E-test. E-test values were always lower than the broth dilution values. Establishing and comparing antibiotic susceptibilities of specific B. mallei strains will provide reference information for assessing new antibiotic agents. PMID:11408233
Nedelcu, R; Olsson, P; Nyström, I; Rydén, J; Thor, A
2018-02-01
To evaluate a novel methodology using industrial scanners as a reference, and assess in vivo accuracy of 3 intraoral scanners (IOS) and conventional impressions. Further, to evaluate IOS precision in vivo. Four reference-bodies were bonded to the buccal surfaces of upper premolars and incisors in five subjects. After three reference-scans, ATOS Core 80 (ATOS), subjects were scanned three times with three IOS systems: 3M True Definition (3M), CEREC Omnicam (OMNI) and Trios 3 (TRIOS). One conventional impression (IMPR) was taken, 3M Impregum Penta Soft, and poured models were digitized with laboratory scanner 3shape D1000 (D1000). Best-fit alignment of reference-bodies and 3D Compare Analysis was performed. Precision of ATOS and D1000 was assessed for quantitative evaluation and comparison. Accuracy of IOS and IMPR were analyzed using ATOS as reference. Precision of IOS was evaluated through intra-system comparison. Precision of ATOS reference scanner (mean 0.6 μm) and D1000 (mean 0.5 μm) was high. Pairwise multiple comparisons of reference-bodies located in different tooth positions displayed a statistically significant difference of accuracy between two scanner-groups: 3M and TRIOS, over OMNI (p value range 0.0001 to 0.0006). IMPR did not show any statistically significant difference to IOS. However, deviations of IOS and IMPR were within a similar magnitude. No statistical difference was found for IOS precision. The methodology can be used for assessing accuracy of IOS and IMPR in vivo in up to five units bilaterally from midline. 3M and TRIOS had a higher accuracy than OMNI. IMPR overlapped both groups. Intraoral scanners can be used as a replacement for conventional impressions when restoring up to ten units without extended edentulous spans. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin
2013-01-01
Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of equivalence of participants in CCQM-K12. The range of participants' results in EURAMET.QM-K12 for both levels (2% and 3% respectively for materials A and B) was greater than the 1% achieved in CCQM-K12. However, it was concluded that this study was suitable to support CMCs for creatinine in serum for 1 µg/g to 100 µg/g with uncertainties at the 1% to 1.5% level. This was found to be fit for purpose and consistent with the majority of CMCs currently approved. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Poynard, Thierry; Pham, Tam; Perazzo, Hugo; Munteanu, Mona; Luckina, Elena; Elaribi, Djamel; Ngo, Yen; Bonyhay, Luminita; Seurat, Noemie; Legroux, Muriel; Ngo, An; Deckmyn, Olivier; Thabut, Dominique; Ratziu, Vlad; Lucidarme, Olivier
2016-01-01
Real-time shear wave elastography (2D-SWE) is a two-dimensional transient elastography and a competitor as a biomarker of liver fibrosis in comparison with the standard reference transient elastography by M probe (TE-M). The aims were to compare several criteria of applicability, and to assess inflammation and steatosis impact on elasticity values, two unmet needs. We took FibroTest as the fibrosis reference and ActiTest and SteatoTest as quantitative estimates of inflammation and steatosis. After standardization of estimates, analyses used curve fitting, quantitative Lin concordance coefficient [LCC], and multivariate logistic regression. A total of 2,251 consecutive patients were included. We validated the predetermined 0.2 kPa cut-off as a too low minimal elasticity value identifying not-reliable 2D-SWE results (LCC with FibroTest = 0.0281[-0.119;0.175]. Other criteria, elasticity CV, body mass index and depth of measures were not sufficiently discriminant. The applicability of 2D-SWE (95%CI) 89.6%(88.2-90.8), was significantly higher than that of TE, 85.6%(84.0-87.0; P<0.0001). In patients with non-advanced fibrosis (METAVIR F0F1F2), elasticity values estimated by 2D-SWE was less impacted by inflammation and steatosis than elasticity value estimated by TE-M: LCC (95%CI) 0.039 (0.021;0.058) vs 0.090 (0.068;0.112;P<0.01) and 0.105 (0.068;0.141) vs 0.192 (0.153;0.230; P<0.01) respectively. The three analyses methods gave similar results. Elasticity results including very low minimal signal in the region of interest should be considered not reliable. 2D-SWE had a higher applicability than TE, the reference elastography, with less impact of inflammation and steatosis especially in patients with non-advanced fibrosis, as presumed by blood tests. ClinicalTrials.gov NCT01927133.
de Jesus, Fillipe M; Magalhães, Luis A G; Kodlulovich, Simone
2016-11-01
A pilot study of dose indicators in paediatric computed tomography (CT) was conducted to prove the need to establish diagnostic reference levels (DRLs) for the county of Rio de Janeiro. The dose descriptors were estimated from the beam dosimetry by applying the protocols used in each examination. The total patient sample included 279 children. Regarding the comparison of the dose-length product values among the hospitals, the high-resolution chest CT scans were distinguished among the three types of examinations, due to the discrepancies of 1148 % (1-5 y age group) and 2248 % (5-10 y age group) presented in Hospital A's dose-length product values relative to Hospital D's dose-length product values. The results showed that without DRL, the dose variation can be significant between hospitals in the same county for the same age group in the same examination. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Discrimination of human and nonhuman blood using Raman spectroscopy with self-reference algorithm
NASA Astrophysics Data System (ADS)
Bian, Haiyi; Wang, Peng; Wang, Jun; Yin, Huancai; Tian, Yubing; Bai, Pengli; Wu, Xiaodong; Wang, Ning; Tang, Yuguo; Gao, Jing
2017-09-01
We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm-1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm-1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C-H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.
Zaid, Abdel Naser; Al Ramahi, Rowa’; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar
2015-01-01
Objective The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix® clopidogrel bisulfate 75 mg film-coated tablets. Methods Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. Results The relationship between concentration and peak area ratio was found to be linear within the range 24.500–1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration–time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration Cmax, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%–125%) specified by the US Food and Drug Administration and the European Medicines Agency. Conclusion The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference. PMID:25987833
Zaid, Abdel Naser; Al Ramahi, Rowa'; Bustami, Rana; Mousa, Ayman; Khasawneh, Sewar
2015-01-01
The aim of this study was to evaluate the bioequivalence of two drug products, generic clopidogrel bisulfate 75 mg film-coated tablets versus the reference Plavix(®) clopidogrel bisulfate 75 mg film-coated tablets. Bioequivalence of tablets was tested by comparisons against the reference brand product in accordance with the requirements of the Declaration of Helsinki, the current Good Clinical Practice Guidelines, and the International Conference on Harmonization. The relationship between concentration and peak area ratio was found to be linear within the range 24.500-1,836.600 pg/mL for clopidogrel. The correlation coefficient (r) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between test and reference. The point estimates (ratios of geometric mean) were 104.122%, 104.184%, and 109.091% for areas under the plasma concentration-time curve (AUC) AUC0-last, AUC0-∞, and peak plasma concentration C max, respectively. These pharmacokinetic parameter values of clopidogrel and its main metabolite lie within the bioequivalence limit (80%-125%) specified by the US Food and Drug Administration and the European Medicines Agency. The tested drug product was bioequivalent to the reference drug under fasting conditions and had the same safety profile, which is important to achieve equivalent therapeutic effect with the reference.
Gerlach, Trevor J; Bandt, Carsten; Conner, Bobbi; Ball, Ray L
2015-11-01
To establish reference ranges for coagulation parameters in healthy Florida manatees (Trichechus manatus latirostris) and compare results with those for debilitated manatees undergoing treatment at a rehabilitation facility. Prospective study. 29 healthy manatees and 45 debilitated manatees with various diseases. Manatees considered healthy on the basis of results of physical examination, CBC, and serum biochemical analysis underwent coagulation testing including measurement of prothrombin time, partial thromboplastin time, D-dimer concentration, platelet count, and fibrinogen concentration to establish reference ranges. For comparison, a group of manatees undergoing rehabilitation was also tested, and the results were compared. Thromboelastography was also performed on some animals. Values for D-dimer concentration were significantly higher in debilitated versus healthy animals. There was no significant difference for prothrombin time, partial thromboplastin time, platelet count, or fibrinogen concentration between groups. Thromboelastography was performed on 8 healthy animals. Reference ranges were established for various tests of coagulation that may assist clinicians during the initial evaluation and rehabilitation of Florida manatees. Future research to evaluate the effect of specific disease processes on the coagulation cascade is recommended.
Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P
2014-01-01
The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger age and drop moderately as age increases. We have presented NHANES reference curves applicable to DXA whole-body scans acquired on GE Healthcare Lunar systems by age, sex and ethnicity. Users of GE Healthcare GE-Lunar DXA systems can now benefit from the large body composition reference data set collected in the NHANES 1999-2004 study. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
[Muscle strength of the cervical and lumbar spine in triathletes].
Miltner, O; Siebert, C H; Müller-Rath, R; Kieffer, O
2010-12-01
The goal of this study was to analyse the muscle strength of the cervical and lumbar spine in ironman triathletes. The values were compared to the results obtained from a reference group. The test of the triathletes was carried out in an attempt to define a specific strength profile for these athletes. In this study, 20 long-distance triathletes (∅ 37.3 ± 7.6 years of age, ∅ 1.80 ± 0.1 m, ∅ 73.7 ± 6.0 kg) were evaluated with regard to their individual and sport-specific strengths of the cervical spine in 2 planes and of the trunk strengths in all 3 planes of motion. The trunk strength profile of the triathletes revealed good average results in the trunk extensors and the lateral flexors of the left trunk. The reference group is the data base of the company Proxomed®, Alzenau. It is based on results of 1045 untrained, symptom-free subjects of different ages. Lumbar extension: The extension of the force values shows no significant difference from the reference group. Lumbar flexion: The flexion tests show highly significantly lower force values (5.025 ± 0.81 N/kg vs. 6.67 ± 0.6 N/kg) than the reference group. Flexion/extension: In the sagittal plane values for the triathletes demonstrate an imbalance in muscle strength ratios. The abdominal muscles turn in relation to the back extensor muscles too weakly to be very significant. Lumbar rotation: The force values of the athletes in both directions (right: 6.185 ± 1.46 N/kg, left: 7.1 ± 1.57 N/kg vs. 10.05 ± 0.34 N/kg) are highly significantly (p ≤ 0.001) lower than the reference values. Ratio of rotation left/right: The ratio of left/right rotation in the reference group is set at 1 and thus shows an equally strong force level between the two sides. Lumbar lateral flexion: The triathletes do not show any significant differences between the force values. Compared to the reference group there is no significant difference to the left side flexion. In the lateral bending the athletes have significantly better values than the reference group. Ratio of lateral left/right: In the reference group the ratio is set at 1. For triathletes, it shows an average value of 0.93. This difference is not significant. Cervical extension: The extension of the force values (1.96 ± 0.59 N/kg vs. 3.03 ± 0.24 N/kg) shows a highly significant difference from the reference group. Cervical flexion: In flexion (1.3 ± 0.42 N/kg vs. 2.17 ± 0.22 N/kg) triathletes have highly significantly lower strength values than the reference group. Flexion/extension: The triathletes did not differ significantly from the reference values (0.69 ± 0.23 and 0.72 ± 0.08). Lateral cervical spine: In comparison to the reference group (left: 1.67 ± 0.48 N/kg, right: 1.55 ± 0.46 N/kg vs. 2.36 ± 0.15 N/kg) in which there is left/right lateral flexion, there is a highly significant difference. Right lateral flexion is weaker than the left. Ratio of lateral left/right: The triathletes have a significant imbalance in the lateral flexion of the cervical spine compared to the reference group (1.07 ± 0.15 to 1). In conclusion, in the triathlon there is a specific stress that is obviously not an adequate stimulus for the muscles of the cervical spine in order to achieve a balanced musculature and the athletes should be advised to practice a preventive approach with regard to these areas. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.
2017-01-01
In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.
2003-01-01
This report summarizes the results of a regional key comparison (APMP-IC-2-97) under the aegis of the Asia Pacific Metrology Program (APMP) for pressure measurements in gas media and in gauge mode from 0.4 MPa to 4.0 MPa. The transfer standard was a pressure-balance with a piston-cylinder assembly with nominal effective area 8.4 mm2 (V-407) and was supplied by the National Metrology Institute of Japan [NMIJ]. Ten standard laboratories from the APMP region with one specially invited laboratory from the EUROMET region, namely Physikalisch-Technische Bundesanstalt (PTB), Germany, participated in this comparison. The comparison started in October 1998 and was completed in May 2001. The pilot laboratory prepared the calibration procedure [1] as per the guidelines of APMP and the International Bureau of Weights and Measures (BIPM) [2-4]. Detailed instructions for performing this key comparison were provided in the calibration protocol [1] and the required data were described in: (1) Annex 3 - characteristics of the laboratory standards, (2) Annex 4 - the effective area (A'p'/mm2) (the prime indicates values based on measured quantities) at 23°C of the travelling standard as a function of nominal pressure (p'/MPa) (five cycles both increasing and decreasing pressures at ten pre-determined pressure points) and (3) Annex 5 - the average effective area at 23°C (A'p'/mm2) obtained for each pressure p'/MPa with all uncertainty statements. The pilot laboratory processed the information and the data provided by the participants for these three annexes, starting with the information about the standards as provided in Annex 3. Based on this information, the participating laboratories are classified into two categories: (I) laboratories that are maintaining primary standards, and (II) laboratories that are maintaining standards loosely classified as secondary standards with a clear traceability as per norm of the BIPM. It is observed that out of these eleven laboratories, six laboratories have primary standards [Category (I)], the remaining five laboratories are placed in Category (II). The obtained data were compiled and processed under the same program as per the Consultative Committee for Mass and Related Quantities (CCM)/BIPM guidelines. From the data of Category (I), we evaluated the APMP reference value as a function of p'/MPa. Then, we estimated the relative difference of the A'p' values with reference to the APMP reference value for all participating laboratories and we observed that they agree well within their expanded uncertainties. We further estimated the effective area at null pressure and at 23°C (A'0/mm2) and the pressure distortion coefficient (lambda'/MPa-1) of the transfer standard for all the participating laboratories. We then estimated the relative deviation of the A'0/mm2 from the reference value for all eleven laboratories and compared this with their estimated expanded uncertainties. The result is once again extremely encouraging and all these eleven laboratories are agreeing within their estimated maximum expanded uncertainties. We also estimated the degree of equivalence between any two participating laboratories following a matrix mechanism. This once again agrees extremely well within the estimated relative standard uncertainty, which is derived for the two participating laboratories. Finally, a new method has been introduced to evaluate these results and establish a link to CCM.P-K1c and EUROMET.M.P-K2 at two nominal pressures, near 1 MPa and 4 MPa. Again the results show an agreement of all participating laboratories in the present comparison to within the estimated expanded uncertainties using a coverage factor k = 2. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual Recognition Arrangement (MRA).
Comparison of ASTM D613 and ASTM D6890
2016-04-01
product , process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement...state or reflect those of the United States Government or the DoA, and shall not be used for advertising or product endorsement purposes...methylnaphthalene proved to be an impractical material for reference values. The ASTM Diesel National Exchange Group ran a study and determined that
NASA Astrophysics Data System (ADS)
Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.; Walden, J.; Augusto, C. R.; Fioravante, A. L.; Ribeiro, C. C.; Sobrinho, D. C. G.; Oudwater, R. J.; da Cunha, V. S.
2014-01-01
Nitrogen monoxide is one of the main contaminants present in the atmospheric air due to emissions of vehicles and power stations. Taking into account the positive experience of VNIIM in the pilot study CCQM-P73 (Nitrogen monoxide gas standards, 30 µmol/mol to 70 µmol/mol), a COOMET project (No 483/RU/09) on the subject was decided and registered in the KCDB as supplementary comparison COOMET.QM-S1. This involved six National Metrology Institutes, aiming to consolidate or support their Calibration and Measurement Capabilities in this field. It was found that most of the results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±1.3% and not exceeding either the appropriate assigned expanded uncertainties. There was, however, one exception: the INMETRO difference from the reference value is slightly higher than the expended uncertainty. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Krissinel, Boris
2018-03-01
The paper reports the results of calculations of the center-to-limb intensity of optically thin line emission in EUV and FUV wavelength ranges. The calculations employ a multicomponent model for the quiescent solar corona. The model includes a collection of loops of various sizes, spicules, and free (inter-loop) matter. Theoretical intensity values are found from probabilities of encountering parts of loops in the line of sight with respect to the probability of absence of other coronal components. The model uses 12 loops with sizes from 3200 to 210000 km with different values of rarefaction index and pressure at the loop base and apex. The temperature at loop apices is 1 400 000 K. The calculations utilize the CHIANTI database. The comparison between theoretical and observed emission intensity values for coronal and transition region lines obtained by the SUMER, CDS, and EIS telescopes shows quite satisfactory agreement between them, particularly for the solar disk center. For the data acquired above the limb, the enhanced discrepancies after the analysis refer to errors in EIS measurements.
Grip strength and body composition in Turkana pastoralist children and adolescents.
Little, Michael A
2017-03-01
In an earlier study, age changes and sex differences in grip strength were documented for adult Turkana pastoralists of Kenya (Little and Johnson, 1986). The objective here is to characterize age changes and sex differences in grip strength of Turkana children and adolescents in the context of arm lean tissue composition, and in comparison with other African, African-American, and non-Western populations. Anthropometric measurements, derived body composition values, and grip strength measures (maximum voluntary contraction) were taken on a sample of 232 nomadic Turkana pastoralist children (94 boys and 138 girls) aged 3 to 21 years. Relationships were tested between grip strength (in Newtons) and mid-upper arm (brachium) lean tissue cross-sectional areas. Comparisons were made among several different ethnic groups. Turkana children and adolescents had low arm muscle (derived lean tissue) and grip strength values when compared with U.S. NHANES percentile references. Girls' percentile rankings were greater than boys' percentile rankings for muscle and for grip strength. Both boys and girls were intermediate when compared with other non-Western populations and U.S. strength grip reference values. Correlations between grip strength and arm lean tissue areas were highly significant for both boys and girls. The greater relative muscle size and grip strength values of late adolescent girls compared to boys is consistent with an earlier study of adults. The difference is likely to result from greater physical subsistence activity and greater access to food in girls than in boys. Several suggestions are given to explain why Turkana youths have relatively small muscle sizes. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Peselnick, L.
1982-08-01
An ultrasonic method is presented which combines features of the differential path and the phase comparison methods. The proposed differential path phase comparison method, referred to as the `hybrid' method for brevity, eliminates errors resulting from phase changes in the bond between the sample and buffer rod. Define r(P) [and R(P)] as the square of the normalized frequency for cancellation of sample waves for shear [and for compressional] waves. Define N as the number of wavelengths in twice the sample length. The pressure derivatives r'(P) and R' (P) for samples of Alcoa 2024-T4 aluminum were obtained by using the phase comparison and the hybrid methods. The values of the pressure derivatives obtained by using the phase comparison method show variations by as much as 40% for small values of N (N < 50). The pressure derivatives as determined from the hybrid method are reproducible to within ±2% independent of N. The values of the pressure derivatives determined by the phase comparison method for large N are the same as those determined by the hybrid method. Advantages of the hybrid method are (1) no pressure dependent phase shift at the buffer-sample interface, (2) elimination of deviatoric stress in the sample portion of the sample assembly with application of hydrostatic pressure, and (3) operation at lower ultrasonic frequencies (for comparable sample lengths), which eliminates detrimental high frequency ultrasonic problems. A reduction of the uncertainties of the pressure derivatives of single crystals and of low porosity polycrystals permits extrapolation of such experimental data to deeper mantle depths.
NASA Astrophysics Data System (ADS)
Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.
2012-01-01
This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Evaluation of six TPS algorithms in computing entrance and exit doses.
Tan, Yun I; Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun; Elliott, Alex
2014-05-08
Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%-3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison.
Demura, Shinichi; Sato, Susumu; Nakada, Masakatsu; Minami, Masaki; Kitabayashi, Tamotsu
2003-07-01
This study compared the accuracy of body density (Db) estimation methods using hydrostatic weighing without complete head submersion (HW(withoutHS)) of Donnelly et al. (1988) and Donnelly and Sintek (1984) as referenced to Goldman and Buskirk's approach (1961). Donnelly et al.'s method estimates Db from a regression equation using HW(withoutHS), moreover, Donnelly and Sintek's method estimates it from HW(withoutHS) and head anthropometric variables. Fifteen Japanese males (173.8+/-4.5 cm, 63.6+/-5.4 kg, 21.2+/-2.8 years) and fifteen females (161.4+/-5.4 cm, 53.8+/-4.8 kg, 21.0+/-1.4 years) participated in this study. All the subjects were measured for head length, width and HWs under the two conditions of with and without head submersion. In order to examine the consistency of estimation values of Db, the correlation coefficients between the estimation values and the reference (Goldman and Buskirk, 1961) were calculated. The standard errors of estimation (SEE) were calculated by regression analysis using a reference value as a dependent variable and estimation values as independent variables. In addition, the systematic errors of two estimation methods were investigated by the Bland-Altman technique (Bland and Altman, 1986). In the estimation, Donnelly and Sintek's equation showed a high relationship with the reference (r=0.960, p<0.01), but had more differences from the reference compared with Donnelly et al.'s equation. Further studies are needed to develop new prediction equations for Japanese considering sex and individual differences in head anthropometry.
NASA Astrophysics Data System (ADS)
Michotte, C.; Courte, S.; Ratel, G.; Moune, M.; Johansson, L.; Keightley, J.
2010-01-01
In 2007 and 2008 respectively, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of 99mTc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNHB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Establishment of a New National Reference Ensemble of Water Triple Point Cells
NASA Astrophysics Data System (ADS)
Senn, Remo
2017-10-01
The results of the Bilateral Comparison EURAMET.T-K3.5 (w/VSL, The Netherlands) with the goal to link Switzerland's ITS-90 realization (Ar to Al) to the latest key comparisons gave strong indications for a discrepancy in the realization of the triple point of water. Due to the age of the cells of about twenty years, it was decided to replace the complete reference ensemble with new "state-of-the-art" cells. Three new water triple point cells from three different suppliers were purchased, as well as a new maintenance bath for an additional improvement of the realization. In several loops measurements were taken, each cell of both ensembles intercompared, and the deviations and characteristics determined. The measurements show a significant lower average value of the old ensemble of 0.59 ± 0.25 mK (k=2) in comparison with the new one. Likewise, the behavior of the old cells is very unstable with a drift downward during the realization of the triple point. Based on these results the impact of the new ensemble on the ITS-90 realization from Ar to Al was calculated and set in the context to performed calibrations and their related uncertainties in the past. This paper presents the instrumentation, cells, measurement procedure, results, uncertainties and impact of the new national reference ensemble of water triple point cells on the current ITS-90 realization in Switzerland.
Comparative study of methodologies for pulse wave velocity estimation.
Salvi, P; Magnani, E; Valbusa, F; Agnoletti, D; Alecu, C; Joly, L; Benetos, A
2008-10-01
Arterial stiffness, estimated by pulse wave velocity (PWV), is an independent predictor of cardiovascular mortality and morbidity. However, the clinical applicability of these measurements and the elaboration of reference PWV values are difficult due to differences between the various devices used. In a population of 50 subjects aged 20-84 years, we compared PWV measurements with three frequently used devices: the Complior and the PulsePen, both of which determine aortic PWV as the delay between carotid and femoral pressure wave and the PulseTrace, which estimates the Stiffness Index (SI) by analyzing photoplethysmographic waves acquired on the fingertip. PWV was measured twice by each device. Coefficient of variation of PWV was 12.3, 12.4 and 14.5% for PulsePen, Complior and PulseTrace, respectively. These measurements were compared with the reference method, that is, a simultaneous acquisition of pressure waves using two tonometers. High correlation coefficients with the reference method were observed for PulsePen (r = 0.99) and Complior (r = 0.83), whereas for PulseTrace correlation with the reference method was much lower (r = 0.55). Upon Bland-Altman analysis, mean differences of values +/- 2s.d. versus the reference method were -0.15 +/- 0.62 m/s, 2.09 +/- 2.68 m/s and -1.12 +/- 4.92 m/s, for PulsePen, Complior and Pulse-Trace, respectively. This study confirms the reliability of Complior and PulsePen devices in estimating PWV, while the SI determined by the PulseTrace device was found to be inappropriate as a surrogate of PWV. The present results indicate the urgent need for evaluation and comparison of the different devices to standardize PWV measurements and establish reference values.
Marrodán Serrano, María Dolores; González-Montero de Espinosa, Marisa; Herráez, Ángel; Alfaro, Emma Laura; Felipe Bejarano, Ignacio; Carmenate, María Margarita; Prado, Consuelo; Beatriz Lomaglio, Delia; López-Ejeda, Noemí; Martínez, Antonio; Mesa, María Soledad; Méndez Pérez, Betty; Meléndez, Juana María; Moreno Romero, Susana; Pacheco, Jose Luis; Vázquez, Vanessa; Dipierri, José E
2015-12-01
the assessment of the skinfold thickness is an objective measure of adiposity. Therefore, it is a useful tool for nutritional diagnosis and prevention of metabolic risk associated with excess fat in chilhood and adolescence. to provide percentiles of subscapular and triceps skinfolds for Hispanic American schoolchildren and compare them with those published by the Centers for Disease Control and Prevention (CDC) from United States, that it have been commonly used as a reference in most of these countries. subscapular and triceps skinfolds were measured in 9.973 schoolchildren 4-19 aged from Spain, Argentina, Cuba, Venezuela and Mexico with Holtain caliper with 0.2 mm accuracy. Percentiles were obtained with the LMS statistical method and were presented in tables divided in stages of 6 months and in curves graphics. The difference between Hispanic American and CDC mean values were provided for P3, P50 and P97 in mm and also were graphically represented. skinfolds measurements obviously increased with age in both sexes but, in boys, this increase is much more marked in highest percentiles between 8 and 13 years; this maximum is reached earlier than what occurs in CDC reference. In both sexes, all percentiles analized in Hispanic American schoolchildren were higher than the CDC reference except P97 up to 10 or 13 years that was notably smaller. the skinfolds percentiles of Hispanic American children and adolescents differ from CDC that are usually used as reference. The values of subscapular and triceps skinfolds provided in this study, could be applied to populations of a similar ethnic background, especially in comparative studies of body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Saravanabhavan, Gurusankar; Werry, Kate; Walker, Mike; Haines, Douglas; Malowany, Morie; Khoury, Cheryl
2017-03-01
Human biomonitoring reference values are statistical estimates that indicate the upper margin of background exposure to a given chemical at a given time. Nationally representative human biomonitoring data on 176 chemicals, including several metals and trace elements, are available in Canada from 2007 to 2013 through the Canadian Health Measures Survey (CHMS). In this work, we used a systematic approach based on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry to derive reference values (RV 95 s) for metals and trace elements. These RV 95 s were derived for blood and urine matrices in the general Canadian population based on the latest biomonitoring data from the CHMS. Biomarkers were chosen based on specific selection criteria, including widespread detection in Canadians (≥66% detection rate). Reference populations were created for each biomarker by applying appropriate exclusion criteria. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for the sub-populations in cases where partitioning was deemed necessary. The RV 95 s for metals and trace elements in blood ranged from 0.18μg/L for cadmium in young children aged 3-5 years to 7900μg/L for zinc in males aged 20-79 years. In the case of urinary biomarkers, the RV 95 s ranged from 0.17μg/L for antimony in the total population aged 3-79 years to 1400mg/L for fluoride in adults aged 20-79 years. These RV 95 s represent the first set of reference values for metals and trace elements in the general Canadian population. We compare the RV 95 s from other countries where available and discuss factors that could influence such comparisons. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
Zheng, Gaoxing; Qi, Xiaoying; Li, Yuzhu; Zhang, Wei; Yu, Yuguo
2018-01-01
The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG) signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST) has been increasingly applied, while the average reference (AR) was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening). The analysis results revealed the following observations: (1) there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2) there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3) the global brain functional connectivity density (FCD) and local FCD have higher values for REST than for AR under different behavior states; and (4) the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands) higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording. PMID:29593490
International comparison CCQM-K111—propane in nitrogen
NASA Astrophysics Data System (ADS)
van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Oudwater, Rutger J.; Fioravante, Andreia L.; Augusto, Cristiane R.; Coutinho Brum, Mariana; Uehara, Shinji; Akima, Dai; Bae, Hyun Kil; Kang, Namgoo; Woo, Jin-Chun; Liaskos, Christina E.; Rhoderick, George C.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique; Brewer, Paul J.; Brown, Andrew S.; Bartlett, Sam; Downey, Michael L.; Konopelko, L. A.; Kolobova, A. V.; Pankov, A. A.; Orshanskaya, A. A.; Efremova, O. V.
2017-01-01
This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare primary standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as a track A key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities using the flexible scheme, and for propane under the default scheme. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results but one are within +/- 0.2 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Comparing physiographic maps with different categorisations
NASA Astrophysics Data System (ADS)
Zawadzka, J.; Mayr, T.; Bellamy, P.; Corstanje, R.
2015-02-01
This paper addresses the need for a robust map comparison method suitable for finding similarities between thematic maps with different forms of categorisations. In our case, the requirement was to establish the information content of newly derived physiographic maps with regards to set of reference maps for a study area in England and Wales. Physiographic maps were derived from the 90 m resolution SRTM DEM, using a suite of existing and new digital landform mapping methods with the overarching purpose of enhancing the physiographic unit component of the Soil and Terrain database (SOTER). Reference maps were seven soil and landscape datasets mapped at scales ranging from 1:200,000 to 1:5,000,000. A review of commonly used statistical methods for categorical comparisons was performed and of these, the Cramer's V statistic was identified as the most appropriate for comparison of maps with different legends. Interpretation of multiple Cramer's V values resulting from one-by-one comparisons of the physiographic and baseline maps was facilitated by multi-dimensional scaling and calculation of average distances between the maps. The method allowed for finding similarities and dissimilarities amongst physiographic maps and baseline maps and informed the recommendation of the most suitable methodology for terrain analysis in the context of soil mapping.
NASA Astrophysics Data System (ADS)
Kim, Han Sung; Yeom, Yeon Soo; Tat Nguyen, Thang; Choi, Chansoo; Han, Min Cheol; Lee, Jai Ki; Kim, Chan Hyeong; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik; Qiu, Rui; Eckerman, Keith; Chung, Beom Sun
2017-03-01
It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.
Advanced Life Support Research and Technology Development Metric
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
The Metric is one of several measures employed by the NASA to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2004. The values are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. For Fiscal Year 2004, the Advanced Life Support Research and Technology Development Metric value is 2.03 for an Orbiting Research Facility and 1.62 for an Independent Exploration Mission.
Towards a new tool for the evaluation of the quality of ultrasound compressed images.
Delgorge, Cécile; Rosenberger, Christophe; Poisson, Gérard; Vieyres, Pierre
2006-11-01
This paper presents a new tool for the evaluation of ultrasound image compression. The goal is to measure the image quality as easily as with a statistical criterion, and with the same reliability as the one provided by the medical assessment. An initial experiment is proposed to medical experts and represents our reference value for the comparison of evaluation criteria. Twenty-one statistical criteria are selected from the literature. A cumulative absolute similarity measure is defined as a distance between the criterion to evaluate and the reference value. A first fusion method based on a linear combination of criteria is proposed to improve the results obtained by each of them separately. The second proposed approach combines different statistical criteria and uses the medical assessment in a training phase with a support vector machine. Some experimental results are given and show the benefit of fusion.
NASA Astrophysics Data System (ADS)
Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik
2016-06-01
A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.
Final report of the APMP water flow key comparison: APMP.M.FF-K1
NASA Astrophysics Data System (ADS)
Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.
2011-01-01
The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the numbers of equivalence showed values less than 1, indicating equivalence. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Mahabeer, S; Naidoo, C; Norman, R J; Jialal, I; Reddi, K; Joubert, S M
1990-10-01
Clinical parameters, androgen status and lipoprotein lipid profiles were assessed in 10 non-obese and 10 obese patients with polycystic ovarian disease (PCOD) and reference subjects matched for age, height and weight. Both obese and non-obese women with PCOD had significantly higher androgen levels when compared to the reference groups. When comparison of lipoprotein lipid profiles were made between groups, non-obese women with PCOD had significantly higher total cholesterol, triglycerides and LDL-cholesterol levels than non-obese reference subjects. Obese PCOD women manifested significantly higher total cholesterol, LDL-cholesterol, cholesterol/HDL, and LDL/HDL values than did obese reference subjects. Correlations between serum androgens and lipoprotein lipid concentrations in PCOD and normal women were unhelpful. Both non-obese and obese patients with PCOD had significantly higher systolic and diastolic blood pressures (BPs) than the reference groups. Thus, both non-obese and obese women with PCOD manifest hyperandrogenaemia which may result in a male pattern of lipoprotein lipid concentrations.
Understanding arid environments using fossil rodent middens
Pearson, S.; Betancourt, J.L.
2002-01-01
American rodent middens have made a more dramatic contribution to understanding past environments and the development of ecological theory than Australian rodent middens. This relates to differences in the natural environment, the landscape histories, the scale and scientific approaches of the researchers. The comparison demonstrates: the power of synoptic perspectives; the value of thorough macrofossil identification in midden analysis and its potential advance in Australia where pollen has dominated analyses, the value of herbaria and reference collections; the potential of environmental databases; the importance of scientific history and 'critical research mass' and; finally, the opportunistic nature of palaeoecological research. ?? 2002 Elsevier Science Ltd.
Tsetlin, E M; Volkova, R A
1996-01-01
Ninety-eight lots of commercial antirabies vaccine manufactured by Immunopreparat Research and Production Amalgamation have been tested using enzyme immunoassay system for the detection of rabies virus antigens. Comparison of different variants of interpreting and expressing the results helped define the optimal method for assessment of vaccine titer and reference values: optical density value equal to 0.2 is taken as the cut-off. Antigenic activity of the vaccine may be expressed in international units, similarly as immunogenic activity.
Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M
2012-11-01
Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.
Underwater Sound Radiation from Large Raindrops
1991-09-01
decreasing shape of the impact spectrum, one must pick a reference point rather that a peak value to compare one drop with another. For comparison of...34 1. Type I Bubble Spectral Density and Peak Pressure ............... 34 2. Type II Bubble Average Spectral Densities at 1 m on Axis (20 C...32 Table 4. TYPE II BUBBLE AVERAGE PEAK SPECTRAL DENSITY SU M M A RY ............................................. 39 Table 5. SUMMARY
Surface Optical Property Measurements on Bark and Leaf Samples
1990-12-31
individually positionable in sample measurement position. 100% Value Absolute, or in comparison to high-reflectance evaporated gold reference sample...evaporated gold on a smooth fused silica substrate. The absolute 100% measurement requires removing the sample from the measurement position and...choice is evaporated gold on a polished glass substrate. As- already noted, SOC uses two instruments to cover the full spectral region from 0.2 to 40.0
Techno-economic assessment of the Mobil Two-Stage Slurry Fischer-Tropsch/ZSM-5 process
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Sawy, A.; Gray, D.; Neuworth, M.
1984-11-01
A techno-economic assessment of the Mobil Two-Stage Slurry Fischer-Tropsch reactor system was carried out. Mobil bench-scale data were evaluated and scaled to a commercial plant design that produced specification high-octane gasoline and high-cetane diesel fuel. Comparisons were made with three reference plants - a SASOL (US) plant using dry ash Lurgi gasifiers and Synthol synthesis units, a modified SASOL plant with a British Gas Corporation slagging Lurgi gasifier (BGC/Synthol) and a BGC/slurry-phase process based on scaled data from the Koelbel Rheinpreussen-Koppers plant. A conceptual commercial version of the Mobil two-stage process shows a higher process efficiency than a SASOL (US)more » and a BGC/Synthol plant. The Mobil plant gave lower gasoline costs than obtained from the SASOL (US) and BGC/Synthol versions. Comparison with published data from a slurry-phase Fischer-Tropsch (Koelbel) unit indicated that product costs from the Mobil process were within 6% of the Koelbel values. A high-wax version of the Mobil process combined with wax hydrocracking could produce gasoline and diesel fuel at comparable cost to the lowest values achieved from prior published slurry-phase results. 27 references, 18 figures, 49 tables.« less
Bréas, Olivier; Thomas, Freddy; Zeleny, Reinhard; Calderone, Giovanni; Jamin, Eric; Guillou, Claude
2007-01-01
Tetramethylurea (TMU) with a certified D/H ratio is the internal standard for Site-specific Natural Isotope Fractionation measured by Nuclear Magnetic Resonance (SNIF-NMR) analysis of wine ethanol for detection of possible adulterations (Commission Regulation 2676/90). A new batch of a TMU certified reference material (CRM) is currently being prepared. Whereas SNIF-NMR has been employed up to now, Elemental Analysis/Isotope Ratio Mass Spectrometry ((2)H-EA-IRMS) was envisaged as the method of choice for value assignment of the new CRM, as more precise (better repeatable) data might be obtained, resulting in lower uncertainty of the certified value. In order to evaluate the accuracy and intra- and inter-laboratory reproducibility of (2)H-EA-IRMS methods, a laboratory inter-comparison was carried out by analysing TMU and other organic compounds, as well as some waters. The results revealed that experienced laboratories are capable of generating robust and well comparable data, which highlights the emerging potential of IRMS in food authenticity testing. However, a systematic bias between IRMS and SNIF-NMR reference data was observed for TMU; this lack of data consistency rules out the (2)H-IRMS technique for the characterisation measurement of the new TMU CRM.
Regional flow duration curves: Geostatistical techniques versus multivariate regression
Pugliese, Alessio; Farmer, William H.; Castellarin, Attilio; Archfield, Stacey A.; Vogel, Richard M.
2016-01-01
A period-of-record flow duration curve (FDC) represents the relationship between the magnitude and frequency of daily streamflows. Prediction of FDCs is of great importance for locations characterized by sparse or missing streamflow observations. We present a detailed comparison of two methods which are capable of predicting an FDC at ungauged basins: (1) an adaptation of the geostatistical method, Top-kriging, employing a linear weighted average of dimensionless empirical FDCs, standardised with a reference streamflow value; and (2) regional multiple linear regression of streamflow quantiles, perhaps the most common method for the prediction of FDCs at ungauged sites. In particular, Top-kriging relies on a metric for expressing the similarity between catchments computed as the negative deviation of the FDC from a reference streamflow value, which we termed total negative deviation (TND). Comparisons of these two methods are made in 182 largely unregulated river catchments in the southeastern U.S. using a three-fold cross-validation algorithm. Our results reveal that the two methods perform similarly throughout flow-regimes, with average Nash-Sutcliffe Efficiencies 0.566 and 0.662, (0.883 and 0.829 on log-transformed quantiles) for the geostatistical and the linear regression models, respectively. The differences between the reproduction of FDC's occurred mostly for low flows with exceedance probability (i.e. duration) above 0.98.
Findlay, R P; Dimbylow, P J
2009-04-21
If an antenna is located close to a person, the electric and magnetic fields produced by the antenna will vary in the region occupied by the human body. To obtain a mean value of the field for comparison with reference levels, the Institute of Electrical and Electronic Engineers (IEEE) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend spatially averaging the squares of the field strength over the height the body. This study attempts to assess the validity and accuracy of spatial averaging when used for half-wave dipoles at frequencies between 65 MHz and 2 GHz and distances of lambda/2, lambda/4 and lambda/8 from the body. The differences between mean electric field values calculated using ten field measurements and that of the true averaged value were approximately 15% in the 600 MHz to 2 GHz range. The results presented suggest that the use of modern survey equipment, which takes hundreds rather than tens of measurements, is advisable to arrive at a sufficiently accurate mean field value. Whole-body averaged and peak localized SAR values, normalized to calculated spatially averaged fields, were calculated for the NORMAN voxel phantom. It was found that the reference levels were conservative for all whole-body SAR values, but not for localized SAR, particularly in the 1-2 GHz region when the dipole was positioned very close to the body. However, if the maximum field is used for normalization of calculated SAR as opposed to the lower spatially averaged value, the reference levels provide a conservative estimate of the localized SAR basic restriction for all frequencies studied.
Intraocular pressure in the smallest primate aging model: the gray mouse lemur.
Dubicanac, Marko; Joly, Marine; Strüve, Julia; Nolte, Ingo; Mestre-Francés, Nadine; Verdier, Jean-Michel; Zimmermann, Elke
2018-05-01
The aim of this study was to assess the practicability of common tonometers used in veterinary medicine for rapid intraocular pressure (IOP) screening, to calibrate IOP values gained by the tonometers, and to define a reference IOP value for the healthy eye in a new primate model for aging research, the gray mouse lemur. TonoVet ® and the TonoPen ™ measurements were calibrated manometrically in healthy enucleated eyes of mouse lemurs euthanized for veterinary reasons. For comparison of the practicability of both tonometers as a rapid IOP assessment tool for living mouse lemurs, the IOP of 24 eyes of 12 animals held in the hand was measured. To define a standard reference value for IOP in mouse lemurs, 258 healthy animals were measured using the TonoVet ® . Intraocular pressure measurements for the TonoVet ® can be corrected using the formula: y = 0.981 + (1.962*TonoVet ® value), and those for the TonoPen ™ using that of y = 5.38 + (1.426*TonoPen ™ value). The calibrated IOP for a healthy mouse lemur eye was 20.3 ± 2.8 mmHg. The TonoVet ® showed advantages in practicability, for example, small corneal contact area, short and painless corneal contact, shortened total time spent on investigation, as well as the more accurate measured values. IOP measurements of healthy mouse lemur eyes were not affected by age, sex, eye side, or colony. Tonometry using TonoVet ® is the more practicable assessment tool for IOP measurement of the tiny eyes of living mouse lemurs. Pathological deviations can be identified based on the described reference value. © 2016 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.
2014-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Power, O.; Stock, M.
2016-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Power, O.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.
A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of themore » CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.« less
Kêkê, L M; Samouda, H; Jacobs, J; di Pompeo, C; Lemdani, M; Hubert, H; Zitouni, D; Guinhouya, B C
2015-06-01
This study aims to compare three body mass index (BMI)-based classification systems of childhood obesity: the French, the International Obesity Task Force (IOTF) and the World Health Organization (WHO) references. The study involved 1382 schoolchildren, recruited from the Lille Academic District in France in May 2009 aged 8.4±1.7 years (4.0-12.0 years). Their mean height and body mass were 131.5±10.9cm and 30.7±9.2kg, respectively, resulting in a BMI of 17.4±3.2kg/m(2). The weight status was defined according to the three systems considered in this study. The agreement between these references was tested using the Cohen's kappa coefficient. The prevalence of overweight was higher with the WHO references (20.0%) in comparison with the French references (13.8%; P<0.0001) and the IOTF (16.2%; P≤0.01). A similar result was found with obesity (WHO: 11.6% vs. IOTF: 6.7%; or French references: 6.7%; P<0.0001). Agreement between the three references ranged from "moderate" to "perfect" (0.43≤κ≤1.00; P<0.0001). Kappa coefficients were higher when the three references were used to classify children as obese (0.63≤κ≤1.00; P<0.0001) as compared to classification in the overweight (obesity excluded) category (0.43≤κ≤0.94; P<0.0001). When sex and age categories (4-6 years vs. 7-12 years) were considered to define the overweight status, the lowest kappa coefficient was found between the French and WHO references in boys aged 7-12 years (κ=0.28; P<0.0001), and the highest one in girls aged 7-12 years between the French references and IOTF (κ=0.97; P<0.0001). As for obesity, agreement between the three references ranged from 0.60 to 1.00 (P<0.0001), with the lowest values obtained in the comparison of the WHO references against French references or IOTF among boys aged 7-12 years (κ=0.60; P<0.0001). Overall, the WHO references yield an overestimation in overweight and/or obesity within this sample of schoolchildren as compared to the French references and the IOTF. The magnitude of agreement coefficients between the three references depends on of both sex and age categories. The French references seem to be in rather close agreement with the IOTF in defining overweight, especially in 7-12-year-old children. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stathakis, S; Defoor, D; Linden, P
2015-06-15
Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was usedmore » for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.« less
Koenigstein, Stefan; Pöhlmann, Kevin; Held, Christoph; Abele, Doris
2013-05-16
Rising temperatures and other environmental factors influenced by global climate change can cause increased physiological stress for many species and lead to range shifts or regional population extinctions. To advance the understanding of species' response to change and establish links between individual and ecosystem adaptations, physiological reactions have to be compared between populations living in different environments. Although changes in expression of stress genes are relatively easy to quantify, methods for reliable comparison of the data remain a contentious issue. Using normalization algorithms and further methodological considerations, we compare cellular stress response gene expression levels measured by RT-qPCR after air exposure experiments among different subpopulations of three species of the intertidal limpet Nacella. Reference gene assessment algorithms reveal that stable reference genes can differ among investigated populations and / or treatment groups. Normalized expression values point to differential defense strategies to air exposure in the investigated populations, which either employ a pronounced cellular stress response in the inducible Hsp70 forms, or exhibit a comparatively high constitutive expression of Hsps (heat shock proteins) while showing only little response in terms of Hsp induction. This study serves as a case study to explore the methodological prerequisites of physiological stress response comparisons among ecologically and phylogenetically different organisms. To improve the reliability of gene expression data and compare the stress responses of subpopulations under potential genetic divergence, reference gene stability algorithms are valuable and necessary tools. As the Hsp70 isoforms have been shown to play different roles in the acute stress responses and increased constitutive defenses of populations in their different habitats, these comparative studies can yield insight into physiological strategies of adaptation to environmental stress and provide hints for the prudent use of the cellular stress response as a biomarker to study environmental stress and stress adaptation of populations under changing environmental conditions.
NASA Astrophysics Data System (ADS)
Yamaguchi, Kizashi; Nishihara, Satomichi; Saito, Toru; Yamanaka, Shusuke; Kitagawa, Yasutaka; Kawakami, Takashi; Yamada, Satoru; Isobe, Hiroshi; Okumura, Mitsutaka
2015-01-01
First principle calculations of effective exchange integrals (J) in the Heisenberg model for diradical species were performed by both symmetry-adapted (SA) multi-reference (MR) and broken-symmetry (BS) single reference (SR) methods. Mukherjee-type (Mk) state specific (SS) MR coupled-cluster (CC) calculations by the use of natural orbital (NO) references of ROHF, UHF, UDFT and CASSCF solutions were carried out to elucidate J values for di- and poly-radical species. Spin-unrestricted Hartree Fock (UHF) based coupled-cluster (CC) computations were also performed to these species. Comparison between UHF-NO(UNO)-MkMRCC and BS UHF-CC computational results indicated that spin-contamination of UHF-CC solutions still remains at the SD level. In order to eliminate the spin contamination, approximate spin-projection (AP) scheme was applied for UCC, and the AP procedure indeed corrected the error to yield good agreement with MkMRCC in energy. The CC double with spin-unrestricted Brueckner's orbital (UBD) was furthermore employed for these species, showing that spin-contamination involved in UHF solutions is largely suppressed, and therefore AP scheme for UBCCD removed easily the rest of spin-contamination. We also performed spin-unrestricted pure- and hybrid-density functional theory (UDFT) calculations of diradical and polyradical species. Three different computational schemes for total spin angular momentums were examined for the AP correction of the hybrid (H) UDFT. HUDFT calculations followed by AP, HUDFT(AP), yielded the S-T gaps that were qualitatively in good agreement with those of MkMRCCSD, UHF-CC(AP) and UB-CC(AP). Thus a systematic comparison among MkMRCCSD, UCC(AP) UBD(AP) and UDFT(AP) was performed concerning with the first principle calculations of J values in di- and poly-radical species. It was found that BS (AP) methods reproduce MkMRCCSD results, indicating their applicability to large exchange coupled systems.
2013-01-01
Background Rising temperatures and other environmental factors influenced by global climate change can cause increased physiological stress for many species and lead to range shifts or regional population extinctions. To advance the understanding of species’ response to change and establish links between individual and ecosystem adaptations, physiological reactions have to be compared between populations living in different environments. Although changes in expression of stress genes are relatively easy to quantify, methods for reliable comparison of the data remain a contentious issue. Using normalization algorithms and further methodological considerations, we compare cellular stress response gene expression levels measured by RT-qPCR after air exposure experiments among different subpopulations of three species of the intertidal limpet Nacella. Results Reference gene assessment algorithms reveal that stable reference genes can differ among investigated populations and / or treatment groups. Normalized expression values point to differential defense strategies to air exposure in the investigated populations, which either employ a pronounced cellular stress response in the inducible Hsp70 forms, or exhibit a comparatively high constitutive expression of Hsps (heat shock proteins) while showing only little response in terms of Hsp induction. Conclusions This study serves as a case study to explore the methodological prerequisites of physiological stress response comparisons among ecologically and phylogenetically different organisms. To improve the reliability of gene expression data and compare the stress responses of subpopulations under potential genetic divergence, reference gene stability algorithms are valuable and necessary tools. As the Hsp70 isoforms have been shown to play different roles in the acute stress responses and increased constitutive defenses of populations in their different habitats, these comparative studies can yield insight into physiological strategies of adaptation to environmental stress and provide hints for the prudent use of the cellular stress response as a biomarker to study environmental stress and stress adaptation of populations under changing environmental conditions. PMID:23680017
Remote Determination of the in situ Sensitivity of a Streckeisen STS-2 Broadband Seismometer
NASA Astrophysics Data System (ADS)
Uhrhammer, R. A.; Taira, T.; Hellweg, M.
2015-12-01
The sensitivity of a STS-2 broadband seismometer can be determined remotely by two basic methods: 1) via comparison of the inferred ground motions with a reference seismometer, and: 2) via excitation of the calibration coil with a simultaneously recorded stimulus signal. The first method is limited by the accuracy of the reference seismometer and the second method is limited by the accuracy of the motor constant (Gc) of the calibration coil. The accuracy of both methods is also influenced by the signal-to-noise ratio (SNR) in the presence of background seismic noise and the degree of orthogonality of the tri-axial suspension in the STS-2 seismometer. The Streckeisen STS-2 manual states that the signal coil sensitivity (Gs) is 1500 V/(m/s) (+/-1.5%) and it gives Gc to only one decimal place (ie, Gc = 2 g/A). Unfortunately the factory Gc value is not given with sufficient accuracy to be useful for determining the sensitivity of Gs to within 1.5%. Thus we need to determine Gc to enable accurate calibration of the STS-2 via remote excitation of the Gc with a known stimulus. The Berkeley Digital Seismic Network (BDSN) has 12 STS-2 seismometers with co-sited reference sensors (strong motion accelerometers) and they are all recorded by Q330HR data loggers with factory cabling. The procedure is to first verify the sensitivity of the STS-2 signal coils (Gs) via comparison of the ground motions recorded by the STS-2 with the ground motions recorded by the co-sited strong motion accelerometer for an earthquake with has sufficiently high SNR in a passband common to both sensors. The second step in the procedure is to remotely (from Berkeley) excite to calibration coil with a 1 Hz sinusoid which is simultaneously recorded and, using the above measured Gs values, solve for Gc of the calibration coils. The resulting Gc values are typically 2.20-2.50 g/A (accurate to 3+ decimal places) and once the Gc values are found, the STS-2 absolute sensitivity can be determined remotely to an accuracy of better than 1%. The primary advantage of using strong motion accelerometers as the reference instrument is that their absolute calibration can be checked via tilt tests if the need arises.
MaCH-Admix: Genotype Imputation for Admixed Populations
Liu, Eric Yi; Li, Mingyao; Wang, Wei; Li, Yun
2012-01-01
Imputation in admixed populations is an important problem but challenging due to the complex linkage disequilibrium (LD) pattern. The emergence of large reference panels such as that from the 1,000 Genomes Project enables more accurate imputation in general, and in particular for admixed populations and for uncommon variants. To efficiently benefit from these large reference panels, one key issue to consider in modern genotype imputation framework is the selection of effective reference panels. In this work, we consider a number of methods for effective reference panel construction inside a hidden Markov model and specific to each target individual. These methods fall into two categories: identity-by-state (IBS) based and ancestry-weighted approach. We evaluated the performance on individuals from recently admixed populations. Our target samples include 8,421 African Americans and 3,587 Hispanic Americans from the Women’s Health Initiative, which allow assessment of imputation quality for uncommon variants. Our experiments include both large and small reference panels; large, medium, and small target samples; and in genome regions of varying levels of LD. We also include BEAGLE and IMPUTE2 for comparison. Experiment results with large reference panel suggest that our novel piecewise IBS method yields consistently higher imputation quality than other methods/software. The advantage is particularly noteworthy among uncommon variants where we observe up to 5.1% information gain with the difference being highly significant (Wilcoxon signed rank test P-value < 0.0001). Our work is the first that considers various sensible approaches for imputation in admixed populations and presents a comprehensive comparison. PMID:23074066
Wenric, Stephane; Sticca, Tiberio; Caberg, Jean-Hubert; Josse, Claire; Fasquelle, Corinne; Herens, Christian; Jamar, Mauricette; Max, Stéphanie; Gothot, André; Caers, Jo; Bours, Vincent
2017-01-01
An increasing number of bioinformatic tools designed to detect CNVs (copy number variants) in tumor samples based on paired exome data where a matched healthy tissue constitutes the reference have been published in the recent years. The idea of using a pool of unrelated healthy DNA as reference has previously been formulated but not thoroughly validated. As of today, the gold standard for CNV calling is still aCGH but there is an increasing interest in detecting CNVs by exome sequencing. We propose to design a metric allowing the comparison of two CNV profiles, independently of the technique used and assessed the validity of using a pool of unrelated healthy DNA instead of a matched healthy tissue as reference in exome-based CNV detection. We compared the CNV profiles obtained with three different approaches (aCGH, exome sequencing with a matched healthy tissue as reference, exome sequencing with a pool of eight unrelated healthy tissue as reference) on three multiple myeloma samples. We show that the usual analyses performed to compare CNV profiles (deletion/amplification ratios and CNV size distribution) lack in precision when confronted with low LRR values, as they only consider the binary status of each CNV. We show that the metric-based distance constitutes a more accurate comparison of two CNV profiles. Based on these analyses, we conclude that a reliable picture of CNV alterations in multiple myeloma samples can be obtained from whole-exome sequencing in the absence of a matched healthy sample. © 2016 WILEY PERIODICALS, INC.
Sharpless, K E; Gill, L M
2000-01-01
A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of the AOAC triangle. Five of these materials have values assigned for total dietary fiber-the first such information provided for materials available from NIST.
Villalobos Reyes, Marjorie; Mederico, Maracelly; Paoli de Valeri, Mariela; Briceño, Yajaira; Zerpa, Yajaira; Gómez-Pérez, Roald; Camacho, Nolis; Martínez, José Luis; Valeri, Lenín; Arata-Bellabarba, Gabriela
2014-11-01
To obtain local reference values for blood lipids and blood pressure (BP), and to determine the prevalence of metabolic syndrome (MS) in children and adolescents from Mérida, Venezuela, and to compare results using local and international cut-off values. The study enrolled 916 participants of both sexes aged 9-18 years of age from educational institutions. Demographic, anthropometric, and BP data were collected. Fasting blood glucose and lipid profile were measured. Percentile distribution of lipid and BP values was done by age group and sex. Prevalence of MS was estimated based on the NCEP-ATPIII classification (as modified by Cook et al.) and the classification of the International Diabetes Federation, using percentiles of Mérida and the USA as cut-off points. Agreement between both classifications was estimated using the kappa test (κ). Prevalence of MS was 2.2% by Cook-Merida percentiles, as compared to 1.8% by Cook-USA percentiles, a moderate agreement (κ=0.54). Agreement between Cook et al. and IDF using Merida percentiles was weak (κ=0.28). There was a higher frequency of abdominal obesity, hypertriglyceridemia and hypertension, and a lower frequency of low HDL-C using Mérida percentiles. The risk (odds ratio) of having MS is greater if abdominal obesity exists (OR: 98.63, CI: 22.45-433.35, p=0.0001). MS was significantly more common in obese subjects (18.3%, p=0.0001). Prevalence of MS in this sample of children and adolescents was 2.2%. Lipid and BP values were lower in Venezuelan as compared to US, European, and Asian children and adolescents, and similar to those in Latin-American references. Own reference values are required for accurate diagnosis of MS, as well as a worldwide consensus on its diagnostic criteria. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.
Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie
2013-01-01
Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449
NASA Astrophysics Data System (ADS)
Budovsky, Ilya
2010-01-01
The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
NASA Technical Reports Server (NTRS)
Kirstettier, Pierre-Emmanual; Honh, Y.; Gourley, J. J.; Chen, S.; Flamig, Z.; Zhang, J.; Howard, K.; Schwaller, M.; Petersen, W.; Amitai, E.
2011-01-01
Characterization of the error associated to satellite rainfall estimates is a necessary component of deterministic and probabilistic frameworks involving space-born passive and active microwave measurement") for applications ranging from water budget studies to forecasting natural hazards related to extreme rainfall events. We focus here on the error structure of NASA's Tropical Rainfall Measurement Mission (TRMM) Precipitation Radar (PR) quantitative precipitation estimation (QPE) at ground. The problem is addressed by comparison of PR QPEs with reference values derived from ground-based measurements using NOAA/NSSL ground radar-based National Mosaic and QPE system (NMQ/Q2). A preliminary investigation of this subject has been carried out at the PR estimation scale (instantaneous and 5 km) using a three-month data sample in the southern part of US. The primary contribution of this study is the presentation of the detailed steps required to derive trustworthy reference rainfall dataset from Q2 at the PR pixel resolution. It relics on a bias correction and a radar quality index, both of which provide a basis to filter out the less trustworthy Q2 values. Several aspects of PR errors arc revealed and quantified including sensitivity to the processing steps with the reference rainfall, comparisons of rainfall detectability and rainfall rate distributions, spatial representativeness of error, and separation of systematic biases and random errors. The methodology and framework developed herein applies more generally to rainfall rate estimates from other sensors onboard low-earth orbiting satellites such as microwave imagers and dual-wavelength radars such as with the Global Precipitation Measurement (GPM) mission.
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Al-Raees, Ghada Y; Al-Amer, Maryam A; Musaiger, Abdulrahman O; D'Souza, Reshma
2009-01-01
A cross-sectional study was carried out on Bahraini preschoolers aged 2-5 years (354 males and 344 females) to determine the prevalence of overweight and obesity using the World Health Organization and the International Obesity Task Force cut-off values. Weight and height were recorded and body mass index (BMI) was calculated to determine the proportion of overweight and obesity. Using the World Health Organization percentile cut-off values, overweight (12.3%) and obesity (8.4%) was higher in females between 2 and <4 years of age whereas, the proportion of both overweight (8.4%) and obesity (7.2%) were higher in males between 4 and <6 years of age. Relative to the International Obesity Task Force indicators, the World Health Organization cut-off values produced nearly a 2-fold increase in both overweight and obesity at most ages. It is therefore important to ensure that the same cut-off reference values are used to define overweight and obesity particularly in preschoolers. Shifting to the new World Health Organization child growth standards may have important implications for child health programmes.
Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.
2017-01-01
Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884
NASA Astrophysics Data System (ADS)
Kirstetter, P.; Hong, Y.; Gourley, J. J.; Chen, S.; Flamig, Z.; Zhang, J.; Howard, K.; Petersen, W. A.
2011-12-01
Proper characterization of the error structure of TRMM Precipitation Radar (PR) quantitative precipitation estimation (QPE) is needed for their use in TRMM combined products, water budget studies and hydrological modeling applications. Due to the variety of sources of error in spaceborne radar QPE (attenuation of the radar signal, influence of land surface, impact of off-nadir viewing angle, etc.) and the impact of correction algorithms, the problem is addressed by comparison of PR QPEs with reference values derived from ground-based measurements (GV) using NOAA/NSSL's National Mosaic QPE (NMQ) system. An investigation of this subject has been carried out at the PR estimation scale (instantaneous and 5 km) on the basis of a 3-month-long data sample. A significant effort has been carried out to derive a bias-corrected, robust reference rainfall source from NMQ. The GV processing details will be presented along with preliminary results of PR's error characteristics using contingency table statistics, probability distribution comparisons, scatter plots, semi-variograms, and systematic biases and random errors.
NASA Astrophysics Data System (ADS)
Chalyy, V.
2011-01-01
A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Pilot study on peptide purity—synthetic human C-peptide
NASA Astrophysics Data System (ADS)
Josephs, R. D.; Li, M.; Song, D.; Daireaux, A.; Choteau, T.; Stoppacher, N.; Westwood, S.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Melanson, J. E.; Ün, I.; Gören, A. C.; Quaglia, M.; Warren, J.
2017-01-01
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P55.2, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Four Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-P55.2. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a quantitative nuclear magnetic resonance spectroscopy (qNMR) corrected for peptide impurities. Other participants provided results obtained by peptide impurity corrected amino acid analysis (PICAA) or elemental analysis (PICCHN). It was decided to assign reference values based on the KCRVs of CCQM-K115 for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most exhaustive and elaborate set of results is taken for the calculation of the reference value. The reference value for the peptide related impurity mass fractions of the material was 83.3 mg/g with a combined standard uncertainty of 1.5 mg/g. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in many cases only a very small number of impurities have been identified and quantified resulting in an underestimation of the peptide related impurity mass fractions. The reference value for the mass fraction of hCP for CCQM-KP55.2 is 801.8 mg/g with a corresponding combined standard uncertainty of 3.1 mg/g. Inspection of the degree of equivalence plots for CCQM-P55.2 for the mass fraction of hCP shows that three results agree with the reference value. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.
Mining-related metals in terrestrial food webs of the upper Clark Fork River basin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pastorok, R.A.; LaTier, A.J.; Butcher, M.K.
1994-12-31
Fluvial deposits of tailings and other mining-related waste in selected riparian habitats of the Upper Clark Fork River basin (Montana) have resulted in metals enriched soils. The significance of metals exposure to selected wildlife species was evaluated by measuring tissue residues of metals (arsenic, cadmium, copper, lead, zinc) in key dietary species, including dominant grasses (tufted hair grass and redtop), willows, alfalfa, barley, invertebrates (grasshoppers, spiders, and beetles), and deer mice. Average metals concentrations in grasses, invertebrates, and deer mice collected from tailings-affected sites were elevated relative to reference to reference levels. Soil-tissue bioconcentration factors for grasses and invertebrates weremore » generally lower than expected based on the range of values in the literature, indicating the reduced bioavailability of metals from mining waste. In general, metals concentrations in willows, alfalfa, and barley were not elevated above reference levels. Using these data and plausible assumptions for other exposure parameters for white-tailed deer, red fox, and American kestrel, metals intake was estimated for soil and diet ingestion pathways. Comparisons of exposure estimates with toxicity reference values indicated that the elevated concentrations of metals in key food web species do not pose a significant risk to wildlife.« less
Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro
2016-11-01
Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.
Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro
2017-01-01
Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) −1.292 (n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was −0.71%, −0.42% and −0.13%, respectively. For the combined precision, the equation y (CV) = −0.398 × (triglycerides value) + 1.797 (n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time. PMID:26680645
NASA Astrophysics Data System (ADS)
Power, O.; Chayramy, R.; Solve, S.; Stock, M.
2014-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Power, O.; Stock, M.
2014-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Psychosocial workload and stress in the workers’ representative
2012-01-01
Background Using a data set of works councils of trade union IG Metal, this paper investigates psychosocial stress and strain on this specific group in comparison to employees working in administration in general (leadership and non-leadership-role) and a national reference value. Methods For assessing psychosocial work factors on works councils within the sector represented by the trade union IG Metal in Germany, a research by using the German standard version of COPSOQ (Copenhagen Psychosocial Questionnaire) was performed. The instrument includes 87 single items forming 25 aspects of strain and stress. Results from the study group of works councils were compared to those from employees working in administration and to the general population mean (COPSOQ database). Statistical analysis included t-tests, analysis of variance and multiple comparisons of means. To be significant in terms of statistics, p<0.05 (two-tailed) and a minimum deviation of 5 or more points between groups′ mean values identify the relevant values. Results All in all, 309 works councils from a national survey of the German chemical and metalworking industries took part in the study. 113 were full-time works council members (exempted from the duty to perform their regular work), 196 were voluntary members (acting as employee representatives on an honorary basis alongside their normal duties). Comparison between works councils and employees working in administration (leadership roles (N=1810) and non-leadership roles (N=2970)) and for employees in general (N=35.000) showed unfavourable values for works councils for most scales. Significantly higher values indicating higher strain and stress were found for the scales: emotional demands, work-privacy conflict, role conflicts, mobbing, cognitive stress symptoms and burnout. Unfavourable results were obtained for the aspects: quality of leadership, social support, sense of community and general health. Favourable findings were found on the scales: influence at work, quantity of social relations and the partly positive values for quantitative demands and commitment to the workplace. Conclusion Compared to the reference groups, works council members perceive the psychosocial demands of working life as more exhausting for the majority of aspects. This allows several conclusions. One reason may be the extended tasks employee representatives face, an other may be that the education of most works council members does not seem appropriate to the high demands of their managerial and executive tasks. PMID:23101876
The "beauty arch: " a new aesthetic analysis for malar augmentation planning.
Marianetti, Tito Matteo; Cozzolino, Salvatore; Torroni, Andrea; Gasparini, Giulio; Pelo, Sandro
2015-05-01
Midface is a critical area for the aesthetics of the face. Despite malar hypoplasia is often combined with a class III malocclusion, there are few studies focusing on the results of a combined approach of malar implants and Le Fort I. We describe a new aesthetic analysis, named "beauty arch" analysis, for the assessment of sagittal projection of the malar region. We took a reference group of 74 Italian women participating in a national beauty contest in 2011 on which we performed our analysis. We used the ideal values to elaborate the surgical treatment planning of a second group of 45 consecutive female patients affected by skeletal class III malocclusion.Twenty-three patients undergo simultaneous Le Fort I osteotomy and malar implants. From the descriptive statistical comparison of the patients' values before and after orthognathic surgery and malar implants with the reference values, we observed how all parameters considered got closer to the ideal population. We consider our beauty arch a useful help for surgeon in the treatment planning of patients with skeletal malocclusions and malar implants.
Schwenteck, T; Knappe, M; Moros, I
2012-09-01
Golmann applanation tonometry represents a well-established procedure for measuring intraocular pressure (IOP). This implies the necessity of an accurate measurement of IOP with the reference tonometer. One example is the contour tonometer Pascal with a measuring probe, adapted to the cornea geometry, for measuring the IOP and the ocular pulse amplitude. There is controversy of how strongly corneal thickness affects the measurement of IOP. We thus analysed, for a number of eyes, the correlation of IOP, as measured by two types of applanation tonometers and one contour tonometer and the central corneal thickness. In all 158 patient eyes were investigated in a clinical comparison of applanation tonometers AT 870 and Ocuton-A. The study was performed by a trained ophthalmologist and the comparison was in accordance with international standard ISO 8612. In addition, the corneal thickness in the vertex was repeatedly determined using an Oculus Pentacam. The potential effect of central corneal thickness on the IOP as measured by the mentioned tonometers was statistically evaluated by rank correlation analysis. We found that the measured IOP values for the three investigated tonometers were not normally distributed. The central corneal thickness values, in contrast, measured on 158 eyes by means of an ultrasound pachymeter and additionally on 235 eyes by the Pentacam, obeyed a Gaussian distribution. For the correlation analysis of both parameters the Spearman linear rank correlation coefficient (r) was considered. We found a very weak (|r| < 0.2) correlation between central corneal thickness and IOP for all 3 tonometers. The softness of the correlation is also illustrated by a large standard deviation of the regression line. A comparison of the different devices for corneal-thickness measurements shows less variance and a smaller variation coefficient when the ultrasoundpachymeter AL-1000 is used. The measured values for IOP are only very weakly correlated to the central corneal thickness. For the 3 tonometer types studied there is no need to correct the indicated pressure values according to the central corneal thickness of the investigated eye. Clinical comparisons according to the ISO 8612 standard between a tonometer under test and a reference Goldmann applanation tonometer are always a time-consuming procedure. Additional measures to determine the central corneal thickness of every investigated eyes are dispensable. © Georg Thieme Verlag KG Stuttgart · New York.
Taylor, C M; Golding, J; Emond, A M
2014-02-01
For heavy metals that have any degree of transfer though the placenta to the fetus, it is unlikely that there are safe limits for maternal blood levels. The only means of reducing fetal exposure is to minimise maternal exposure. There are few recommendations for levels of concern. With the exception of US recommendations for maternal Pb levels, but there are no international levels of concern or cut-off levels specifically for pregnancy for heavy metals, so that comparisons can generally only be made with national reference values relating to similar physiological statuses or age groups. These include recommendations for Cd levels by Germany (reference value for non-smoking adults aged 18-69 years, 1 µg/l) and for Hg by Germany (reference value for adults age 18-60 years with fish intake < or =3 times per month, 2.0 µg/l) and the USA (cut-off level for women, 5.8 µg/dl). To illustrate the lack of cohesion, we present data on blood Pb, Cd and Hg levels from pregnant women enroled in the UK Avon Longitudinal Study of Parents and Children study and compare the values with present levels of concern and recommended cut-off values. We also compare the levels with those found in other groups of pregnant women worldwide to strengthen the database for the development of levels of concern in pregnancy. The need for clarity of terminology in describing levels of concern is discussed. There is a pressing need for international consensus on levels of concern for all age groups and physiological statuses, particularly for pregnancy.
Pearman, Timothy; Yanez, Betina; Peipert, John; Wortman, Katy; Beaumont, Jennifer; Cella, David
2014-09-15
Health-related quality of life (HRQOL) measures are commonly used in oncology research. Interest in their use for monitoring or screening is increasing. The Functional Assessment of Cancer Therapy (FACT) is one of the most widely used HRQOL instruments. Consequently, oncology researchers and practitioners have an increasing need for reference values for the Functional Assessment of Cancer Therapy-General (FACT-G) and its 7-item rapid version, the Functional Assessment of Cancer Therapy-General 7 (FACT-G7), to compare FACT scores across specific subgroups of patients in research trials and practice. The objectives of this study are to provide 1) reference values from a sample of the general US adult population and a sample of adults diagnosed with cancer and 2) cutoff scores for quality of life. A sample of the general US population (N = 1075) and a sample of patients with cancer from 12 studies (N = 5065) were analyzed. Cutoff scores were established using distribution- and anchor-based methods. Mean values for the cancer sample were analyzed by performance status, cancer type, and disease status. Also, t tests and established criteria for meaningful differences were used to compare values. FACT-G and FACT-G7 scores in the general US population sample and cancer sample were generally comparable. Among the sample of patients with cancer, FACT-G and FACT-G7 scores worsened with declining performance status and increasing disease status. These data will aid interpretation of the magnitude and meaning of FACT scores, and allow for comparisons of scores across studies. © 2014 American Cancer Society.
CCM key comparison CCM.D-K4 'Hydrometer'
NASA Astrophysics Data System (ADS)
Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.
2016-01-01
This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was added to this comparison so that all participants were engaged after the breakage of the 9340171 artefact. A particularly good agreement was found among the results provided by most of the participants, even if some systematic differences and either underestimated or overestimated uncertainties of the submitted results can be identified with respect to the KCRVs. In general the deviations of the laboratory results to the KCRVs are within of 1/3rd to 1/4th of a scale division and the uncertainty at 95% is usually within half a division. During the analysis of the submitted results, a systematic difference between the first and last immersed mark was also noted, possibly due to a temperature gradient along the stem and/or wetting of the stem around the tested mark, and therefore a corrected claimed uncertainty from each laboratory is expected. However this comparison may help the laboratories to solve some residual or marginal problems as well as to better understand the uncertainty components. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database (KCDB). The results can be used to link regional comparisons to this CCM key comparison Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Evaluation of the Water Film Weber Number in Glaze Icing Scaling
NASA Technical Reports Server (NTRS)
Tsao, Jen-Ching; Kreeger, Richard E.; Feo, Alejandro
2010-01-01
Icing scaling tests were performed in the NASA Glenn Icing Research Tunnel to evaluate a new scaling method, developed and proposed by Feo for glaze icing, in which the scale liquid water content and velocity were found by matching reference and scale values of the nondimensional water-film thickness expression and the film Weber number. For comparison purpose, tests were also conducted using the constant We(sub L) method for velocity scaling. The reference tests used a full-span, fiberglass, 91.4-cm-chord NACA 0012 model with velocities of 76 and 100 knot and MVD sizes of 150 and 195 microns. Scale-to-reference model size ratio was 1:2.6. All tests were made at 0deg AOA. Results will be presented for stagnation point freezing fractions of 0.3 and 0.5.
Shu, Y Y; Lao, R C; Chiu, C H; Turle, R
2000-12-01
The microwave-assisted extraction (MAE) of polycyclic aromatic hydrocarbons (PAHs) from harbor sediment reference material EC-1, marine sediment reference material HS-2 and PAH-spiked river bed soil was conducted. The extraction conditions for EC-1 were carried out at 70 degrees C and 100 degrees C under pressure in closed vessels with cyclohexane acetone (1:1), cyclohexane-water (3:1), hexane acetone (1:1), and hexane-water (3:1) for 10 min. A comparison between MAE and a 16-h Soxhlet extraction (SX) method showed that both techniques gave comparable results with certified values. MAE has advantages over the currently used Soxhlet technique due to a faster extraction time and lower quantity of solvent used. The consumption of organic solvent of the microwave method was less than one-tenth compared to Soxhlet.
NASA Astrophysics Data System (ADS)
Huang, Xuebo
2009-01-01
In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.
Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina
2018-03-01
To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.
Biodegradation of biodiesel fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, X.; Haws, R.; Wright, B.
1995-12-31
Biodiesel fuel test substances Rape Ethyl Ester (REE), Rape Methyl Ester (RME), Neat Rape Oil (NR), Say Methyl Ester (SME), Soy Ethyl Ester (SEE), Neat Soy Oil (NS), and proportionate combinations of RME/diesel and REE/diesel were studied to test the biodegradability of the test substances in an aerobic aquatic environment using the EPA 560/6-82-003 Shake Flask Test Method. A concurrent analysis of Phillips D-2 Reference Diesel was also performed for comparison with a conventional fuel. The highest rates of percent CO{sub 2} evolution were seen in the esterified fuels, although no significant difference was noted between them. Ranges of percentmore » CO{sub 2} evolution for esterified fuels were from 77% to 91%. The neat rape and neat soy oils exhibited 70% to 78% CO{sub 2} evolution. These rates were all significantly higher than those of the Phillips D-2 reference fuel which evolved from 7% to 26% of the organic carbon to CO{sub 2}. The test substances were examined for BOD{sub 5} and COD values as a relative measure of biodegradability. Water Accommodated Fraction (WAF) was experimentally derived and BOD{sub 5} and COD analyses were carried out with a diluted concentration at or below the WAF. The results of analysis at WAF were then converted to pure substance values. The pure substance BOD{sub 5} and COD values for test substances were then compared to a control substance, Phillips D-2 Reference fuel. No significant difference was noted for COD values between test substances and the control fuel. (p > 0.20). The D-2 control substance was significantly lower than all test substances for BCD, values at p << 0.01. RME was also significantly lower than REE (p < 0.05) and MS (p < 0.01) for BOD{sub 5} value.« less
Enhanced pid vs model predictive control applied to bldc motor
NASA Astrophysics Data System (ADS)
Gaya, M. S.; Muhammad, Auwal; Aliyu Abdulkadir, Rabiu; Salim, S. N. S.; Madugu, I. S.; Tijjani, Aminu; Aminu Yusuf, Lukman; Dauda Umar, Ibrahim; Khairi, M. T. M.
2018-01-01
BrushLess Direct Current (BLDC) motor is a multivariable and highly complex nonlinear system. Variation of internal parameter values with environment or reference signal increases the difficulty in controlling the BLDC effectively. Advanced control strategies (like model predictive control) often have to be integrated to satisfy the control desires. Enhancing or proper tuning of a conventional algorithm results in achieving the desired performance. This paper presents a performance comparison of Enhanced PID and Model Predictive Control (MPC) applied to brushless direct current motor. The simulation results demonstrated that the PSO-PID is slightly better than the PID and MPC in tracking the trajectory of the reference signal. The proposed scheme could be useful algorithms for the system.
Comparison of Realizations of the Terrestrial Reference Frame
NASA Technical Reports Server (NTRS)
Ma, C.; Macmillan, D.; Bolotin, S.; Le Bail, K.; Gordon, D.; Gipson, J.
2015-01-01
IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We compared the IGN and DGFI TRFs with a GSFC CALC/SOLVE TRF. WRMS position and velocity differences for the 40 most frequently observed sites were 2-3 mm and 0.3-0.4 mm/year. There was a scale difference of 0.39/0.09 ppb between the IGN/DGFI realizations and the GSFC solution. When we fixed positions and velocities to either the IGN or DGFI values in CALC/SOLVE solutions, the resulting EOP estimates were not significantly different from the estimates from a standard TRF solution.
Body Weight, Length and Head Circumference at Birth in a Cohort of Turkish Newborns
Kurtoğlu, Selim; Hatipoğlu, Nihal; Mazıcıoğlu, Mustafa Mümtaz; Akın, Mustafa Ali; Çoban, Dilek; Gökoğlu, Sonay; Baştuğ, Osman
2012-01-01
Objective: Intrauterine growth references are primarily useful indicators in the assessment of the general health status of newborn infants. Although Lubchenco’s references are still used in many neonatal care units, we believe that there is a need for up-to-date intrauterine growth references specific for different populations. To develop gestational age-and gender-specific national references for birth weight, birth length and head circumference. Methods: Data were collected from neonatal records of perinatology services of eleven hospitals from January to December 2009. The anthropometry of a total of 4750 singleton live births born between 28 and 41 weeks of gestation were recorded. Means and standard deviations were calculated, and percentiles for each gender and gestational week were produced using the LMS program. The results were compared with US infants and also with local data. Results: Gestational age- and gender-specific 3rd, 5th, 10th, 15th, 25th, 50th, 75th, 85th, 90th, 95th and 97th percentile values were produced. Comparison of the 10th, 50th and 90th percentile values showed that the boys were heavier and longer than the girls. Head circumference values were also higher in the boys. Proportions of small for gestational age (SGA), appropriate for gestational age (AGA) and large for gestational age (LGA) infants in the sample were 10.1%, 79.1% and 10.8%, respectively. Conclusion: These gender- and gestational age-specific references will be of use in clinical practice and also for research purposes until more comprehensive, reliable and accessible national data pertaining to the intrauterine growth of Turkish infants are produced. Conflict of interest:None declared. PMID:22664362
New Carbonate Standard Reference Materials for Boron Isotope Geochemistry
NASA Astrophysics Data System (ADS)
Stewart, J.; Christopher, S. J.; Day, R. D.
2015-12-01
The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and Geoanalytical Research, 2004. 28(3): p. 411-416.
Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)
NASA Astrophysics Data System (ADS)
Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola
2015-01-01
Cosmetics are used in practically all walks of life as a means of improving skin and beautifying complexion. In recent years, more and more attention has been paid to the cosmetic safety. In response to the cosmetic safety issue, the accurate measurement of the heavy metals in cosmetics is, therefore, particularly important. NMIs from different countries should establish their chemical metrology traceability system in this area, which includes both measurement methods research and certain CRMs development. It should be noted that because the matrix of many cosmetics is complex and the contents of the heavy metals are relatively low, it still is a challenging task to measure the analytes with high accuracy and precision. CCQM-K106 followed up CCQM pilot study 'CCQM-P128: Pb, As measurements in cosmetic (cream)' coordinated by the National Institute of Metrology, China (NIM) in 2009. The cream was selected as the testing material, which is widely used as a daily skin care worldwide. This is the first CCQM key comparison regarding the measurement of toxic metal elements with the cosmetic matrix, which includes pure water, liquid paraffin, silicone oil, synthetic squalane, hyaluronic acid, glycerin, propylene glycol, allantoin, preservative and so on. The aim of the CCQM-K106 is to demonstrate the capability of participating NMIs and designated institutes in measuring the contents of poisonous elements, including lead, arsenic and mercury in a cosmetic sample (cream), and support CMC claims relating to inorganic elements in cosmetic materials and similar chemical industry products. The cream matrix sample was prepared under the guidance of professional technicians. The formula of the cream was carefully chosen to match with a real cosmetic. The homogeneity and stability level of Pb, As and Hg in the cream sample were fit for the objective of the comparison. Each participant received two numbered bottles containing about 5g samples in each bottle. The instruction relating to CCQM-K106 was sent to each participant by e-mail, which consisted of technical protocol, results report form and inorganic core capabilities tables. The results were reported as mass faction (mg/kg). Calculation of the uncertainty expressed as a combined standard uncertainty and an expanded uncertainty at 95% confidence. In order to allow a sufficient evaluation of the comparison, the report was required to include a detailed description of the applied method of measurement, information about sample digestion and preparation, information about the reference material used for calibration. The methods of measurement were free to be selected by the participants. For the sample treatment, most of the participants used microwave digestion method. For instrumental determination, a variety of techniques such as ICP-MS, AAS, INAA were adopted by the participants. Most participants choose ID-ICP-MS method to measure Pb and Hg, which showed the better performance in terms of consistency and reliability of the measurement results. The reference mass fraction values and associated uncertainties were calculated by different statistic ways. As the result, the median and uncertainty of median were proposed as the key comparison reference value (KCRV) and its associated key comparison reference uncertainty after removal of suspected extreme values. In general, the performances of the majority of the CCQM-K106 participants are excellent, illustrating their measurement capability for Pb, As and Hg in a complex greasy matrix. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Maccioni, Francesca; Al Ansari, Najwa; Mazzamurro, Fabrizio; Civitelli, Fortunata; Viola, Franca; Cucchiara, Salvatore; Catalano, Carlo
2014-11-01
The purpose of this article is to prospectively determine the accuracy of MR enterography in detecting Crohn disease lesions from the jejunum to the anorectal region in pediatric patients, in comparison with main reference investigations. Fifty consecutive children with known Crohn disease underwent MR enterography with oral contrast agent and gadolinium-chelate intravenous injection. Two radiologists detected and localized lesions by dividing the bowel into nine segments (450 analyzed segments in 50 patients). Ileocolonoscopy, barium studies, intestinal ultrasound, and capsule endoscopy were considered as first- and second-level reference examinations and were performed within 15 days of MR enterography. MR enterography detected lesions in 164 of 450 segments, with 155 true-positive and nine false-positive findings; overall sensitivity, specificity, and positive and negative predictive values for small- and large-bowel lesions were 94.5%, 97%, 94.5%, and 97%, respectively (ĸ = 0.93; 95% CI, 0.89-0.97). Sensitivity and specificity values were 88% and 97%, respectively, for the jejunum, 100% and 97% for the proximal-to-mid ileum, 100% and 100% for the distal ileum, 93% and 100% for the cecum, 70% and 97% for the ascending colon, 80% and 100% for the transverse colon, 100% and 92% for the descending colon, 96% and 90% for the sigmoid colon, and 96% and 88% for the rectum. From jejunum to rectum, the AUC value ranged between 0.916 (jejunum) and 1.00 (distal ileum). Perianal fistulas were diagnosed in 15 patients, and other complications were found in 13 patients. MR enterography showed an accuracy comparable to that of reference investigations, for both small- and large-bowel lesions. Because MR enterography is safer and more comprehensive than the reference examinations, it should be considered the primary examination for detecting Crohn disease lesions in children.
Assessment of crack opening area for leak rates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharples, J.K.; Bouchard, P.J.
1997-04-01
This paper outlines the background to recommended crack opening area solutions given in a proposed revision to leak before break guidance for the R6 procedure. Comparisons with experimental and analytical results are given for some selected cases of circumferential cracks in cylinders. It is shown that elastic models can provide satisfactory estimations of crack opening displacement (and area) but they become increasingly conservative for values of L{sub r} greater than approximately 0.4. The Dugdale small scale yielding model gives conservative estimates of crack opening displacement with increasing enhancement for L{sub r} values greater than 0.4. Further validation of the elastic-plasticmore » reference stress method for up to L{sub r} values of about 1.0 is presented by experimental and analytical comparisons. Although a more detailed method, its application gives a best estimate of crack opening displacement which may be substantially greater than small scale plasticity models. It is also shown that the local boundary conditions in pipework need to be carefully considered when evaluating crack opening area for through-wall bending stresses resulting from welding residual stresses or geometry discontinuities.« less
Poynard, Thierry; Pham, Tam; Perazzo, Hugo; Munteanu, Mona; Luckina, Elena; Elaribi, Djamel; Ngo, Yen; Bonyhay, Luminita; Seurat, Noemie; Legroux, Muriel; Ngo, An; Deckmyn, Olivier; Thabut, Dominique; Ratziu, Vlad; Lucidarme, Olivier
2016-01-01
Background and Aims Real-time shear wave elastography (2D-SWE) is a two-dimensional transient elastography and a competitor as a biomarker of liver fibrosis in comparison with the standard reference transient elastography by M probe (TE-M). The aims were to compare several criteria of applicability, and to assess inflammation and steatosis impact on elasticity values, two unmet needs. Methods We took FibroTest as the fibrosis reference and ActiTest and SteatoTest as quantitative estimates of inflammation and steatosis. After standardization of estimates, analyses used curve fitting, quantitative Lin concordance coefficient [LCC], and multivariate logistic regression. Results A total of 2,251 consecutive patients were included. We validated the predetermined 0.2 kPa cut-off as a too low minimal elasticity value identifying not-reliable 2D-SWE results (LCC with FibroTest = 0.0281[-0.119;0.175]. Other criteria, elasticity CV, body mass index and depth of measures were not sufficiently discriminant. The applicability of 2D-SWE (95%CI) 89.6%(88.2–90.8), was significantly higher than that of TE, 85.6%(84.0–87.0; P<0.0001). In patients with non-advanced fibrosis (METAVIR F0F1F2), elasticity values estimated by 2D-SWE was less impacted by inflammation and steatosis than elasticity value estimated by TE-M: LCC (95%CI) 0.039 (0.021;0.058) vs 0.090 (0.068;0.112;P<0.01) and 0.105 (0.068;0.141) vs 0.192 (0.153;0.230; P<0.01) respectively. The three analyses methods gave similar results. Conclusions Elasticity results including very low minimal signal in the region of interest should be considered not reliable. 2D-SWE had a higher applicability than TE, the reference elastography, with less impact of inflammation and steatosis especially in patients with non-advanced fibrosis, as presumed by blood tests. Trial Registration ClinicalTrials.gov NCT01927133 PMID:27706177
Kerns, James R; Followill, David S; Lowenstein, Jessica; Molineu, Andrea; Alvarez, Paola; Taylor, Paige A; Stingo, Francesco C; Kry, Stephen F
2016-05-01
Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Distributions of the parameter data were shown to be robust and derive from a student's t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist's acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.
Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope
2009-04-01
The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.
Okunade, Akintunde A.
2007-01-01
In order to achieve uniformity in radiological imaging, it is recommended that the concept of equivalence in shape (quality) and size (quantity) of clinical Xray beams should be used for carrying out the comparative evaluation of image and patient dose. When used under the same irradiation geometry, X-ray beams that are strictly or relatively equivalent in terms of shape and size will produce identical or relatively identical image quality and patient dose. Simple mathematical models and software program EQSPECT.FOR were developed for the comparative evaluation of the performance characteristics in terms of contrast (C), contrast to noise ratio (CNR) and figure-of-merit (FOM = CNR2/DOSE) for spectrally equivalent beams transmitted through filter materials referred to as conventional and k-edged. At the same value of operating potential (kVp), results show that spectrally equivalent beam transmitted through conventional filter with higher atomic number (Z-value) in comparison with that transmitted through conventional filter with lower Z-value resulted in the same value of C and FOM. However, in comparison with the spectrally equivalent beam transmitted through filter of lower Z-value, the beam through filter of higher Z-value produced higher value of CNR and DOSE at equal tube loading (mAs) and kVp. Under the condition of equivalence of spectrum, at scaled (or reduced) tube loading and same kVp, filter materials of higher Z-value can produce the same values of C, CNR, DOSE and FOM as filter materials of lower Z-value. Unlike the case of comparison of spectrally equivalent beam transmitted through one conventional filter and that through another conventional filter, it is not possible to derive simple mathematical formulations for the relative performance of spectrally equivalent beam transmitted through a given conventional filter material and that through kedge filter material. PMID:21224928
Daleu, C. L.; Plant, R. S.; Woolnough, S. J.; ...
2015-10-24
Here, as part of an international intercomparison project, a set of single-column models (SCMs) and cloud-resolving models (CRMs) are run under the weak-temperature gradient (WTG) method and the damped gravity wave (DGW) method. For each model, the implementation of the WTG or DGW method involves a simulated column which is coupled to a reference state defined with profiles obtained from the same model in radiative-convective equilibrium. The simulated column has the same surface conditions as the reference state and is initialized with profiles from the reference state. We performed systematic comparison of the behavior of different models under a consistentmore » implementation of the WTG method and the DGW method and systematic comparison of the WTG and DGW methods in models with different physics and numerics. CRMs and SCMs produce a variety of behaviors under both WTG and DGW methods. Some of the models reproduce the reference state while others sustain a large-scale circulation which results in either substantially lower or higher precipitation compared to the value of the reference state. CRMs show a fairly linear relationship between precipitation and circulation strength. SCMs display a wider range of behaviors than CRMs. Some SCMs under the WTG method produce zero precipitation. Within an individual SCM, a DGW simulation and a corresponding WTG simulation can produce different signed circulation. When initialized with a dry troposphere, DGW simulations always result in a precipitating equilibrium state. The greatest sensitivities to the initial moisture conditions occur for multiple stable equilibria in some WTG simulations, corresponding to either a dry equilibrium state when initialized as dry or a precipitating equilibrium state when initialized as moist. Multiple equilibria are seen in more WTG simulations for higher SST. In some models, the existence of multiple equilibria is sensitive to some parameters in the WTG calculations.« less
Development and validation of a cancer-specific swallowing assessment tool: MASA-C.
Carnaby, Giselle D; Crary, Michael A
2014-03-01
We present data from a sample of patients receiving radiotherapy for head/neck cancer to define and measure the validity of a new clinical assessment measure for swallowing. Fifty-eight patients undergoing radiotherapy (±chemotherapy) for head/neck cancer (HNC) supported the development of a physiology-based assessment tool of swallowing (Mann Assessment of Swallowing Ability--Cancer: MASA-C) administered at two time points (baseline and following radiotherapy treatment). The new exam was evaluated for internal consistency of items using Cronbach's alpha. Reliability of measurement was evaluated with intraclass correlation (ICC) and the Kappa statistic between two independent raters. Concurrent validity was established through comparison with the original MASA examination and against the referent standard videofluoroscopic swallowing examination (VFE). Sensitivity, specificity, and likelihood ratios along with 95 % confidence intervals (CIs) were derived for comparison of the two evaluation forms (MASA vs. MASA-C). Accuracy of diagnostic precision was displayed using receiver operator characteristic curves. The new MASA-C tool demonstrated superior validity to the original MASA examination applied to a HNC population. In comparison to the VFE referent exam, the MASA-C revealed strong sensitivity and specificity (Se 83, Sp 96), predictive values (positive predictive value (PPV) 0.95, negative predictive value (NPV) 0.86), and likelihood ratios (21.6). In addition, it demonstrated good reliability (ICC = 0.96) between speech-language pathology raters. The MASA-C is a reliable and valid scale that is sensitive to differences in swallowing performance in HNC patients with and without dysphagia. Future longitudinal evaluation of this tool in larger samples is suggested. The development and refinement of this swallowing assessment tool for use in multidisciplinary HNC teams will facilitate earlier identification of patients with swallowing difficulties and enable more efficient allocation of resources to the management of dysphagia in this population. The MASA-C may also prove useful in future clinical HNC rehabilitation trials with this population.
NASA Astrophysics Data System (ADS)
Xu, Jing; Liu, Xiaofei; Wang, Yutian
2016-08-01
Parallel factor analysis is a widely used method to extract qualitative and quantitative information of the analyte of interest from fluorescence emission-excitation matrix containing unknown components. Big amplitude of scattering will influence the results of parallel factor analysis. Many methods of eliminating scattering have been proposed. Each of these methods has its advantages and disadvantages. The combination of symmetrical subtraction and interpolated values has been discussed. The combination refers to both the combination of results and the combination of methods. Nine methods were used for comparison. The results show the combination of results can make a better concentration prediction for all the components.
CCQM-K90, formaldehyde in nitrogen, 2 μmol mol-1 Final report
NASA Astrophysics Data System (ADS)
Viallon, Joële; Flores, Edgar; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert Ian; Kim, D.; Kim, Y. D.; Lee, S.; Persijn, S.; Konopelko, L. A.; Kustikov, Y. A.; Malginov, A. V.; Chubchenko, I. K.; Klimov, A. Y.; Efremova, O. V.; Zhou, Z.; Possolo, A.; Shimosaka, T.; Brewer, P.; Macé, T.; Ferracci, Valerio; Brown, Richard J. C.; Aoki, Nobuyuki
2017-01-01
The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 μmol mol-1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Yozova, Ivayla D; Howard, Judith; Henke, Diana; Dirkmann, Daniel; Adamik, Katja N
2017-06-19
Hyperosmolar therapy with either mannitol or hypertonic saline (HTS) is commonly used in the treatment of intracranial hypertension (ICH). In vitro data indicate that both mannitol and HTS affect coagulation and platelet function in dogs. The aim of this study was to compare the effects of 20% mannitol and 7.2% HTS on whole blood coagulation using rotational thromboelastometry (ROTEM®) and platelet function using a platelet function analyzer (PFA®) in dogs with suspected ICH. Thirty client-owned dogs with suspected ICH needing osmotherapy were randomized to receive either 20% mannitol (5 ml/kg IV over 15 min) or 7.2% HTS (4 ml/kg IV over 5 min). ROTEM® (EXTEM® and FIBTEM® assays) and PFA® analyses (collagen/ADP cartridges) were performed before (T 0 ), as well as 5 (T 5 ), 60 (T 60 ) and 120 (T 120 ) minutes after administration of HTS or mannitol. Data at T 5 , T 60 and T 120 were analyzed as a percentage of values at T 0 for comparison between groups, and as absolute values for comparison between time points, respectively. No significant difference was found between the groups for the percentage change of any parameter at any time point except for FIBTEM® clotting time. Within each group, no significant difference was found between time points for any parameter except for FIBTEM® clotting time in the HTS group, and EXTEM® and FIBTEM® maximum clot firmness in the mannitol group. Median ROTEM® values lay within institutional reference intervals in both groups at all time points, whereas median PFA® values were above the reference intervals at T 5 (both groups) and T 60 (HTS group). Using currently recommended doses, mannitol and HTS do not differ in their effects on whole blood coagulation and platelet function in dogs with suspected ICH. Moreover, no relevant impairment of whole blood coagulation was found following treatment with either solution, whereas a short-lived impairment of platelet function was found after both solutions.
NASA Astrophysics Data System (ADS)
Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.
2016-01-01
This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Final report on the regional supplementary comparison APMP.AUV.A-S1
NASA Astrophysics Data System (ADS)
Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung
2014-01-01
A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Varrone, Andrea; Gulyás, Balázs; Takano, Akihiro; Stabin, Michael G; Jonsson, Cathrine; Halldin, Christer
2012-02-01
[(18)F]FE-PE2I is a promising dopamine transporter (DAT) radioligand. In nonhuman primates, we examined the accuracy of simplified quantification methods and the estimates of radiation dose of [(18)F]FE-PE2I. In the quantification study, binding potential (BP(ND)) values previously reported in three rhesus monkeys using kinetic and graphical analyses of [(18)F]FE-PE2I were used for comparison. BP(ND) using the cerebellum as reference region was obtained with four reference tissue methods applied to the [(18)F]FE-PE2I data that were compared with the kinetic and graphical analyses. In the whole-body study, estimates of adsorbed radiation were obtained in two cynomolgus monkeys. All reference tissue methods provided BP(ND) values within 5% of the values obtained with the kinetic and graphical analyses. The shortest imaging time for stable BP(ND) estimation was 54 min. The average effective dose of [(18)F]FE-PE2I was 0.021 mSv/MBq, similar to 2-deoxy-2-[(18)F]fluoro-d-glucose. The results in nonhuman primates suggest that [(18)F]FE-PE2I is suitable for accurate and stable DAT quantification, and its radiation dose estimates would allow for a maximal administered radioactivity of 476 MBq in human subjects. Copyright © 2012 Elsevier Inc. All rights reserved.
[European community guidelines and standards in indoor air quality: what proposals for Italy].
Settimo, Gaetano; D'Alessandro, Daniela
2014-01-01
Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.
NASA Astrophysics Data System (ADS)
Ding, Liang; Wang, Shui; Cai, Bingjie; Zhang, Mancheng; Qu, Changsheng
2018-02-01
In this study, portable X-ray fluorescence spectrometry (pXRF) was used to measure the heavy metal contents of As, Cu, Cr, Ni, Pb and Zn in the soils of heavy metal-contaminated sites. The precision, accuracy and system errors of pXRF were evaluated and compared with traditional laboratory methods to examine the suitability of in situ pXRF. The results show that the pXRF analysis achieved satisfactory accuracy and precision in measuring As, Cr, Cu, Ni, Pb, and Zn in soils, and meets the requirements of the relevant detection technology specifications. For the certified reference soil samples, the pXRF results of As, Cr, Cu, Ni, Pb, and Zn show good linear relationships and coefficients of determination with the values measured using the reference analysis methods; with the exception of Ni, all the measured values were within the 95% confidence level. In the soil samples, the coefficients of determination between Cu, Zn, Pb, and Ni concentrations measured laboratory pXRF and the values measured with laboratory analysis all reach 0.9, showing a good linear relationship; however, there were large deviations between methods for Cr and As. This study provides reference data and scientific support for rapid detection of heavy metals in soils using pXRF in site investigation, which can better guide the practical application of pXRF.
NASA Astrophysics Data System (ADS)
Janssen, Christof; Elandaloussi, Hadj; Gröbner, Julian
2018-03-01
The room temperature (294.09 K) absorption cross section of ozone at the 325 nm HeCd wavelength has been determined under careful consideration of possible biases. At the vacuum wavelength of 325.126 nm, thus in a region used by a variety of ozone remote sensing techniques, an absorption cross-section value of σ = 16.470×10-21 cm2 was measured. The measurement provides the currently most accurate direct photometric absorption value of ozone in the UV with an expanded (coverage factor k = 2) standard uncertainty u(σ) = 31×10-24 cm2, corresponding to a relative level of 2 ‰. The measurements are most compatible with a relative temperature coefficient cT = σ-1 ∂ Tσ = 0.0031 K-1 at 294 K. The cross section and its uncertainty value were obtained using generalised linear regression with correlated uncertainties. It will serve as a reference for ozone absorption spectra required for the long-term remote sensing of atmospheric ozone in the Huggins bands. The comparison with commonly used absorption cross-section data sets for remote sensing reveals a possible bias of about 2 %. This could partly explain a 4 % discrepancy between UV and IR remote sensing data and indicates that further studies will be required to reach the accuracy goal of 1 % in atmospheric reference spectra.
Cawello, Willi; Schäfer, Carina
2014-08-01
Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.
Entropy vs. energy waveform processing: A comparison based on the heat equation
Hughes, Michael S.; McCarthy, John E.; Bruillard, Paul J.; ...
2015-05-25
Virtually all modern imaging devices collect electromagnetic or acoustic waves and use the energy carried by these waves to determine pixel values to create what is basically an “energy” picture. However, waves also carry “information”, as quantified by some form of entropy, and this may also be used to produce an “information” image. Numerous published studies have demonstrated the advantages of entropy, or “information imaging”, over conventional methods. The most sensitive information measure appears to be the joint entropy of the collected wave and a reference signal. The sensitivity of repeated experimental observations of a slowly-changing quantity may be definedmore » as the mean variation (i.e., observed change) divided by mean variance (i.e., noise). Wiener integration permits computation of the required mean values and variances as solutions to the heat equation, permitting estimation of their relative magnitudes. There always exists a reference, such that joint entropy has larger variation and smaller variance than the corresponding quantities for signal energy, matching observations of several studies. Moreover, a general prescription for finding an “optimal” reference for the joint entropy emerges, which also has been validated in several studies.« less
Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W
2013-12-01
To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.
Identification of Dynapenia in Older Adults Through the Use of Grip Strength T-Scores
Bohannon, Richard W; Magasi, Susan
2014-01-01
Objective To generate reference values and t-scores (1.0 to 2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Design Secondary analysis of cross-sectional grip strength data from the NIH Toolbox norming sample. Setting Population-based general community sample. Participants Community dwelling adults, between the ages 20 and 40 years (n=558); and 60 to 85 years (n=390) Main Outcomes Measures Grip strength measured with a Jamar plus dynamometer. Results Maximum grip strengths were consistent over the 20–40 year age span. For men they were 108.0 lbs (S.D. 22.6). For women, they were 65.8 lbs (S.D. 14.6) Comparison of older participant grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2–87.1% of older men and 50.0–82.4% of older women could be designated as dynapenic on the basis of t-scores. Conclusion The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. PMID:24729356
Identification of dynapenia in older adults through the use of grip strength t-scores.
Bohannon, Richard W; Magasi, Susan
2015-01-01
The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zakharchenko, V. D.; Kovalenko, I. G.; Pak, O. V.; Ryzhkov, V. Yu.
2018-05-01
The problem of coherence violation in stroboscopic ranging with a high resolution in the range due to mutual phase instability of probing and reference radio signals has been considered. It has been shown that the violation of coherence in stroboscopic ranging systems is equivalent to the action of modulating interface and leads to a decrease in the system sensitivity. Requirements have been formulated for the coherence of reference generators in the stroboscopic processing system. The results of statistical modeling have been presented. It was shown that, in the current state of technology with stability of the frequencies of the reference generators, the achieved coherence is sufficient to probe asteroids with super-resolving signals in the range of up to 70 million kilometers. In this case, the dispersion of the signal in cosmic plasma limits the value of the linear resolution of the asteroid details at this range by the value of 2.7 m. Comparison with the current radar resolution of asteroids has been considered, which, at the end of 2015, were 7.5 m in the range of 7 million kilometers.
Hlushak, S P; Cummings, P T; McCabe, C
2013-12-21
Adsorption of flexible oligomers into narrow cylindrical pores has been studied by means of several versions of classical density functional theory (CDFT) and Monte Carlo simulation. The adsorption process is interesting to study due to the competition between the entropic depletion of oligomers from the pores and the wall-oligomer attraction. It is also challenging to describe using current CDFTs, which tend to overestimate the amount of the adsorbed fluid. From a comparison of several different CDFT approaches, we find that this is due to the assumption of ideal or freely jointed chain conformations. Moreover, it is demonstrated that it is impossible to obtain a reasonable description of the adsorption isotherms without taking into account accurate contact values in the distribution functions describing the structure of the reference monomer fluid. At low densities, more accurate result are obtained in comparison with Monte Carlo simulation data when accurate contact values are incorporated into the theory rather than the more commonly used hard-sphere contact value. However, even the CDFT with accurate contact values still overestimates the amount of the adsorbed fluid due to the ideal or freely jointed chain approximation, used for the description of chain conformations in most CDFT approaches. We find that significant improvement can achieved by employing self-consistent field theory, which samples self-avoiding chain conformations and decreases the number of possible chain conformations, and, consequently, the amount of the adsorbed fluid.
Ladwiniec, Andrew; Cunnington, Michael S; Rossington, Jennifer; Thackray, Simon; Alamgir, Farquad; Hoye, Angela
2016-05-01
The aim of this study was to compare microvascular resistance under both baseline and hyperemic conditions immediately after percutaneous coronary intervention (PCI) of a chronic total occlusion (CTO) with an unobstructed reference vessel in the same patient Microvascular dysfunction has been reported to be prevalent immediately after CTO PCI. However, previous studies have not made comparison with a reference vessel. Patients with a CTO may have global microvascular and/or endothelial dysfunction, making comparison with established normal values misleading. After successful CTO PCI in 21 consecutive patients, coronary pressure and flow velocity were measured at baseline and hyperemia in distal segments of the CTO/target vessel and an unobstructed reference vessel. Hemodynamics including hyperemic microvascular resistance (HMR), basal microvascular resistance (BMR), and instantaneous minimal microvascular resistance at baseline and hyperemia were calculated and compared between reference and target/CTO vessels. After CTO PCI, BMR was reduced in the target/CTO vessel compared with the reference vessel: 3.58 mm Hg/cm/s vs 4.94 mm Hg/cm/s, difference -1.36 mm Hg/cm/s (-2.33 to -0.39, p = 0.008). We did not detect a difference in HMR: 1.82 mm Hg/cm/s vs 2.01 mm Hg/cm/s, difference -0.20 (-0.78 to 0.39, p = 0.49). Instantaneous minimal microvascular resistance correlated strongly with the length of stented segment at baseline (r = 0.63, p = 0.005) and hyperemia (r = 0.68, p = 0.002). BMR is reduced in a recanalized CTO in the immediate aftermath of PCI compared to an unobstructed reference vessel; however, HMR appears to be preserved. A longer stented segment is associated with increased microvascular resistance. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Error and Uncertainty in the Accuracy Assessment of Land Cover Maps
NASA Astrophysics Data System (ADS)
Sarmento, Pedro Alexandre Reis
Traditionally the accuracy assessment of land cover maps is performed through the comparison of these maps with a reference database, which is intended to represent the "real" land cover, being this comparison reported with the thematic accuracy measures through confusion matrixes. Although, these reference databases are also a representation of reality, containing errors due to the human uncertainty in the assignment of the land cover class that best characterizes a certain area, causing bias in the thematic accuracy measures that are reported to the end users of these maps. The main goal of this dissertation is to develop a methodology that allows the integration of human uncertainty present in reference databases in the accuracy assessment of land cover maps, and analyse the impacts that uncertainty may have in the thematic accuracy measures reported to the end users of land cover maps. The utility of the inclusion of human uncertainty in the accuracy assessment of land cover maps is investigated. Specifically we studied the utility of fuzzy sets theory, more precisely of fuzzy arithmetic, for a better understanding of human uncertainty associated to the elaboration of reference databases, and their impacts in the thematic accuracy measures that are derived from confusion matrixes. For this purpose linguistic values transformed in fuzzy intervals that address the uncertainty in the elaboration of reference databases were used to compute fuzzy confusion matrixes. The proposed methodology is illustrated using a case study in which the accuracy assessment of a land cover map for Continental Portugal derived from Medium Resolution Imaging Spectrometer (MERIS) is made. The obtained results demonstrate that the inclusion of human uncertainty in reference databases provides much more information about the quality of land cover maps, when compared with the traditional approach of accuracy assessment of land cover maps. None
Physical profile of elite young motorcyclists.
Sánchez-Muñoz, C; Rodríguez, M A; Casimiro-Andújar, A J; Ortega, F B; Mateo-March, M; Zabala, M
2011-10-01
The aim of the study was to describe anthropometric and physical characteristics of elite young road-race motorcyclists (MC). 27 riders (15.6±1.1 years, 54.6±6.9 kg, 166.9±6.7 cm) competing at international elite level participated in this study. Anthropometric variables, hand grip and lumbar isometric strength, and lower-body muscular strength were measured. Comparisons of the MC and a reference group of Spanish physically active adolescents (16.0±0.6 years) showed that the riders were significantly lighter (-12.5 kg), and smaller (-4.7 cm). Riders also had significantly lower values for almost all skinfolds, and for all the measured girths (except forearm) than the reference group. Motorcyclists showed significantly less percent body fat (%BF) and higher muscle mass, and differences were observed for somatotype components compared to the reference group, except for the ectomorphy. Somatotype could be defined as mesomorphic-ectomorph (2.5-4.4-3.7). Mean (±SD) values of all riders were 34.8±5.0 cm for vertical jump height, 402.1±74.5 N for the right hand and 370.7±77.5 N for the left hand strengths, and 120.6±19.3 kg for lumbar isometric strength, respectively. Results demonstrate that MC are small and light, with lower body mass index, skinfolds, girth and breadth dimensions, and %BF than a reference group and other athletes, with high values of hand grip and lumbar isometric strength. © Georg Thieme Verlag KG Stuttgart · New York.
Hosseininasab, Abufazel; Mohammadi, Mohammadreza; Jouzi, Samira; Esmaeilinasab, Maryam; Delavar, Ali
2016-01-01
Objective: This study aimed to provide a normative study documenting how 114 five-seven year-old non-patient Iranian children respond to the Rorschach test. We compared this especial sample to international normative reference values for the Comprehensive System (CS). Method: One hundred fourteen 5- 7- year-old non-patient Iranian children were recruited from public schools. Using five child and adolescent samples from five countries, we compared Iranian Normative Reference Data- based on reference means and standard deviations for each sample. Results: Findings revealed that how the scores in each sample were distributed and how the samples were compared across variables in eight Rorschach Comprehensive System (CS) clusters. We reported all descriptive statistics such as reference mean and standard deviation for all variables. Conclusion: Iranian clinicians could rely on country specific or “local norms” when assessing children. We discourage Iranian clinicians to use many CS scores to make nomothetic, score-based inferences about psychopathology in children and adolescents. PMID:27928247
Ice-Accretion Scaling Using Water-Film Thickness Parameters
NASA Technical Reports Server (NTRS)
Anderson, David N.; Feo, Alejandro
2003-01-01
Studies were performed at INTA in Spain to determine water-film thickness on a stagnation-point probe inserted in a simulated cloud. The measurements were correlated with non-dimensional parameters describing the flow and the cloud conditions. Icing scaling tests in the NASA Glenn Icing Research Tunnel were then conducted using the Ruff scaling method with the scale velocity found by matching scale and reference values of either the INTA non-dimensional water-film thickness or a Weber number based on that film thickness. For comparison, tests were also performed using the constant drop-size Weber number and the average-velocity methods. The reference and scale models were both aluminum, 61-cm-span, NACA 0012 airfoil sections at 0 deg. AOA. The reference had a 53-cm-chord and the scale, 27 cm (1/2 size). Both models were mounted vertically in the center of the IRT test section. Tests covered a freezing fraction range of 0.28 to 1.0. Rime ice (n = 1.0) tests showed the consistency of the IRT calibration over a range of velocities. At a freezing fraction of 0.76, there was no significant difference in the scale ice shapes produced by the different methods. For freezing fractions of 0.40, 0.52 and 0.61, somewhat better agreement with the reference horn angles was typically achieved with the average-velocity and constant-film thickness methods than when either of the two Weber numbers was matched to the reference value. At a freezing fraction of 0.28, the four methods were judged equal in providing simulations of the reference shape.
Caselli, Thaisa Barboza; Lomazi, Elizete Aparecida; Montenegro, Maria Augusta Santos; Bellomo-Brandão, Maria Angela
2017-01-01
Due to several factors, such as gastrointestinal's diseases and difficulty in feeding, children with Spastic Quadriplegic Cerebral Palsy tend to present nutritional deficits. To assess the nutritional status of pediatric patients with Spastic Quadriplegic Cerebral Palsy according to reference curves for this population and with the measures of folds and circumferences, obtained by the upper arm circumference and triceps skin fold. The data were obtained from: knee-height, estimated height, weight, upper arm circumference, and triceps skin fold. Values of folds and circumferences were compared with Frisancho, and specific curves for these patients were used as reference. The relationship between the values in the growth curve for healthy children, Z-Score, and comparison with the reference curve were verified by Fisher's exact test. We adopted the significance level of 5%. We evaluated 54 patients. The mean age was 10.2 years, and 34 were male, 25 fed by gastrostomy and 29, orally. The frequency of low weight by the reference curve was 22.22%. More than half of the patients presented the parameters indicating lean mass below the 5th percentile. The height of all patients was classified as adequate for the age by the reference curve. Low weight was found in 22% of patients, and there is a greater tendency to present reduced muscle mass and increased fat mass, showing the need for evaluation and appropriate interventions for patients with Spastic Quadriplegic Cerebral Palsy.
Ionospheric tomography over South Africa: Comparison of MIDAS and ionosondes measurements
NASA Astrophysics Data System (ADS)
Giday, Nigussie M.; Katamzi, Zama T.; McKinnell, Lee-Anne
2016-01-01
This paper aims to show the results of an ionospheric tomography algorithm called Multi-Instrument Data Analysis System (MIDAS) over the South African region. Recorded data from a network of 49-53 Global Positioning System (GPS) receivers over the South African region was used as input for the inversion. The inversion was made for April, July, October and December representing the four distinct seasons (Autumn, Winter, Spring and Summer respectively) of the year 2012. MIDAS reconstructions were validated by comparing maximum electron density of the F2 layer (NmF2) and peak height (hmF2) values predicted by MIDAS to those derived from three South African ionosonde measurements. The diurnal and seasonal trends of the MIDAS NmF2 values were in good agreement with the respective NmF2 values derived from the ionosondes. In addition, good agreement was found between the two measurements with minimum and maximum coefficients of determination (r2) between 0.84 and 0.96 in all the stations and validation days. The seasonal trend of the NmF2 values over the South Africa region has been reproduced using this inversion which was in good agreement with the ionosonde measurements. Moreover, a comparison of the International Reference Ionosphere (IRI-2012) model NmF2 values with the respective ionosonde derived NmF2 values showed to have higher deviation than a similar comparison between the MIDAS reconstruction and the ionosonde measurements. However, the monthly averaged hmF2 values derived from IRI 2012 model showed better agreement than the respective MIDAS reconstructed hmF2 values compared with the ionosonde derived hmF2 values.The performance of the MIDAS reconstruction was observed to deteriorate with increased geomagnetic conditions. MIDAS reconstructed electron density were slightly elevated during three storm periods studied (24 April, 15 July and 8 October) which was in good agreement with the ionosonde measurements.
Kaminsky, Leonard A; Imboden, Mary T; Arena, Ross; Myers, Jonathan
2017-02-01
The importance of cardiorespiratory fitness (CRF) is well established. This report provides newly developed standards for CRF reference values derived from cardiopulmonary exercise testing (CPX) using cycle ergometry in the United States. Ten laboratories in the United States experienced in CPX administration with established quality control procedures contributed to the "Fitness Registry and the Importance of Exercise: A National Database" (FRIEND) Registry from April 2014 through May 2016. Data from 4494 maximal (respiratory exchange ratio, ≥1.1) cycle ergometer tests from men and women (20-79 years) from 27 states, without cardiovascular disease, were used to develop these references values. Percentiles of maximum oxygen consumption (VO 2max ) for men and women were determined for each decade from age 20 years through age 79 years. Comparisons of VO 2max were made to reference data established with CPX data from treadmill data in the FRIEND Registry and previously published reports. As expected, there were significant differences between sex and age groups for VO 2max (P<.01). For cycle tests within the FRIEND Registry, the 50th percentile VO 2max of men and women aged 20 to 29 years declined from 41.9 and 31.0 mLO 2 /kg/min to 19.5 and 14.8 mLO 2 /kg/min for ages 70 to 79 years, respectively. The rate of decline in this cohort was approximately 10% per decade. The FRIEND Registry reference data will be useful in providing more accurate interpretations for the US population of CPX-measured VO 2max from exercise tests using cycle ergometry compared with previous approaches based on estimations of standard differences from treadmill testing reference values. Copyright © 2016 Mayo Foundation for Medical Education and Research. All rights reserved.
NASA Astrophysics Data System (ADS)
Liedberg, Hans
2012-01-01
The Comité Consulatif de Thermométrie (CCT) has organized several key comparisons to compare realizations of the ITS-90 in different National Metrology Institutes. To keep the organization, time scale and data processing of such a comparison manageable, the number of participants in a CCT key comparison (CCT KC) is limited to a few laboratories in each major economic region. Subsequent regional key comparisons are linked to the applicable CCT KC by two or more linking laboratories. For the temperature range from 83.8058 K (triple point of Ar) to 933.473 K (freezing point of Al), a key comparison, CCT-K3, was carried out from 1997 to 2001 among representative laboratories in North America, Europe and Asia. Following CCT-K3, the Asia-Pacific Metrology Program Key Comparison 3 (APMP.T-K3) was organized for National Metrology Institutes in the Asia/Pacific region. NMIA (Australia) and KRISS (South Korea) provided the link between CCT-K3 and APMP.T-K3. APMP.T-K3, which took place from February 2000 to June 2003, covered the temperature range from -38.8344 °C (triple point of Hg) to 419.527 °C (freezing point of Zn), using a standard platinum resistance thermometer (SPRT) as the artefact. In June 2007 the Vietnam Metrology Institute (VMI) requested a bilateral comparison to link their SPRT calibration capabilities to APMP.T-K3, and in October 2007 the National Metrology Institute of South Africa (NMISA) agreed to provide the link to APMP.T-K3. Like APMP.T-K3, the comparison was restricted to the Hg to Zn temperature range to reduce the chance of drift in the SPRT artefact. The comparison was carried out in a participant-pilot-participant topology (with NMISA as the pilot and VMI as the participant). VMI's results in the comparison were linked to the Average Reference Values of CCT-K3 via NMISA's results in APMP.T-K3. The resistance ratios measured by VMI and NMISA at Zn, Sn, Ga and Hg fixed points agree within their combined uncertainties, and VMI's results also agree with the CCT-K3 reference values at these fixed points. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaguchi, Kizashi; Nishihara, Satomichi; Saito, Toru
First principle calculations of effective exchange integrals (J) in the Heisenberg model for diradical species were performed by both symmetry-adapted (SA) multi-reference (MR) and broken-symmetry (BS) single reference (SR) methods. Mukherjee-type (Mk) state specific (SS) MR coupled-cluster (CC) calculations by the use of natural orbital (NO) references of ROHF, UHF, UDFT and CASSCF solutions were carried out to elucidate J values for di- and poly-radical species. Spin-unrestricted Hartree Fock (UHF) based coupled-cluster (CC) computations were also performed to these species. Comparison between UHF-NO(UNO)-MkMRCC and BS UHF-CC computational results indicated that spin-contamination of UHF-CC solutions still remains at the SD level.more » In order to eliminate the spin contamination, approximate spin-projection (AP) scheme was applied for UCC, and the AP procedure indeed corrected the error to yield good agreement with MkMRCC in energy. The CC double with spin-unrestricted Brueckner's orbital (UBD) was furthermore employed for these species, showing that spin-contamination involved in UHF solutions is largely suppressed, and therefore AP scheme for UBCCD removed easily the rest of spin-contamination. We also performed spin-unrestricted pure- and hybrid-density functional theory (UDFT) calculations of diradical and polyradical species. Three different computational schemes for total spin angular momentums were examined for the AP correction of the hybrid (H) UDFT. HUDFT calculations followed by AP, HUDFT(AP), yielded the S-T gaps that were qualitatively in good agreement with those of MkMRCCSD, UHF-CC(AP) and UB-CC(AP). Thus a systematic comparison among MkMRCCSD, UCC(AP) UBD(AP) and UDFT(AP) was performed concerning with the first principle calculations of J values in di- and poly-radical species. It was found that BS (AP) methods reproduce MkMRCCSD results, indicating their applicability to large exchange coupled systems.« less
FT-IR imaging for quantitative determination of liver fat content in non-alcoholic fatty liver.
Kochan, K; Maslak, E; Chlopicki, S; Baranska, M
2015-08-07
In this work we apply FT-IR imaging of large areas of liver tissue cross-section samples (∼5 cm × 5 cm) for quantitative assessment of steatosis in murine model of Non-Alcoholic Fatty Liver (NAFLD). We quantified the area of liver tissue occupied by lipid droplets (LDs) by FT-IR imaging and Oil Red O (ORO) staining for comparison. Two alternative FT-IR based approaches are presented. The first, straightforward method, was based on average spectra from tissues and provided values of the fat content by using a PLS regression model and the reference method. The second one – the chemometric-based method – enabled us to determine the values of the fat content, independently of the reference method by means of k-means cluster (KMC) analysis. In summary, FT-IR images of large size liver sections may prove to be useful for quantifying liver steatosis without the need of tissue staining.
Clinical chemistry and hematology values in a Caribbean population of African green monkeys.
Liddie, Shervin; Goody, Robin J; Valles, Rodrigo; Lawrence, Matthew S
2010-12-01
Hematology and clinical chemistry (HCC) reference values are critical in veterinary practice and in vivo pre-clinical research, enabling detection of health abnormalities, response to therapeutic intervention or adverse toxicological effects, as well as monitoring of clinical management. In this report, reference ranges for 46 HCC parameters were characterized in 331 wild-caught and colony-bred African green monkeys. Effects of sex, weight and duration of captivity were determined by one-way analysis of variance. Significant sex differences were observed for several HCC parameters. Significant differences were also observed for select HCC variables between newly caught animals and those held in captivity for 1-12 months or longer. Comparison of this data with other non-human primate species and humans highlights similarities and disparities between species. Potential causes of interpopulation variability and relevance to the use of the African green monkey as a non-human primate model are discussed. © 2010 John Wiley & Sons A/S.
Microwave assisted extraction for trace element analysis of plant materials by ICP-AES.
Borkowska-Burnecka, J
2000-11-01
Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.
Turk, G C; Yu, L L; Salit, M L; Guthrie, W F
2001-06-01
Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma-mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.
Evaluation of six TPS algorithms in computing entrance and exit doses
Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun P.; Elliott, Alex
2014-01-01
Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%‐3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.N‐, 87.53.Bn PMID:24892349
Micro-mass standards to calibrate the sensitivity of mass comparators
NASA Astrophysics Data System (ADS)
Madec, Tanguy; Mann, Gaëlle; Meury, Paul-André; Rabault, Thierry
2007-10-01
In mass metrology, the standards currently used are calibrated by a chain of comparisons, performed using mass comparators, that extends ultimately from the international prototype (which is the definition of the unit of mass) to the standards in routine use. The differences measured in the course of these comparisons become smaller and smaller as the standards approach the definitions of their units, precisely because of how accurately they have been adjusted. One source of uncertainty in the determination of the difference of mass between the mass compared and the reference mass is the sensitivity error of the comparator used. Unfortunately, in the market there are no mass standards small enough (of the order of a few hundreds of micrograms) for a valid evaluation of this source of uncertainty. The users of these comparators therefore have no choice but to rely on the characteristics claimed by the makers of the comparators, or else to determine this sensitivity error at higher values (at least 1 mg) and interpolate from this result to smaller differences of mass. For this reason, the LNE decided to produce and calibrate micro-mass standards having nominal values between 100 µg and 900 µg. These standards were developed, then tested in multiple comparisons on an A5 type automatic comparator. They have since been qualified and calibrated in a weighing design, repeatedly and over an extended period of time, to establish their stability with respect to oxidation and the harmlessness of the handling and storage procedure associated with their use. Finally, the micro-standards so qualified were used to characterize the sensitivity errors of two of the LNE's mass comparators, including the one used to tie France's Platinum reference standard (Pt 35) to stainless steel and superalloy standards.
Changes in radiation dose with variations in human anatomy: moderately and severely obese adults.
Clark, Landon D; Stabin, Michael G; Fernald, Michael J; Brill, Aaron B
2010-06-01
The phantoms used in standardized dose assessment are based on a median (i.e., 50th percentile) individual of a large population, for example, adult males or females or children of a particular age. Here we describe phantoms that model instead the influence of obesity on specific absorbed fractions (SAFs) and dose factors in adults. The literature was reviewed to evaluate how individual organ sizes change with variations in body weight in mildly and severely obese adult men and women. On the basis of the literature evaluation, changes were made to our deformable reference adult male and female total-body models. Monte Carlo simulations of radiation transport were performed. SAFs for photons were generated for mildly and severely obese adults, and comparisons were made to the reference (50th) percentile SAF values. SAFs studied between the obese phantoms and the 50th percentile reference phantoms were not significantly different from the reference 50th percentile individual, with the exception of intestines irradiating some abdominal organs, because of an increase in separation between folds caused by an increase in mesenteric adipose deposits. Some low-energy values for certain organ pairs were different, possibly due only to the statistical variability of the data at these low energies. The effect of obesity on dose calculations for internal emitters is minor and may be neglected in the routine use of standardized dose estimates.
Utility of Reference Change Values for Delta Check Limits.
Ko, Dae-Hyun; Park, Hae-Il; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Shin, Dong Hoon
2017-10-01
To assess the utility of reference change values (RCVs) as delta check limits. A total of 1,650,518 paired results for 23 general chemistry test results from June 1, 2014, to October 31, 2016, were analyzed. The RCVs for each analyte were calculated from the analytical imprecision and within-subject biological variation. The percent differences between two consecutive results in one patient were categorized into one of four groups: outpatients, inpatients, emergency care, and general health care. For each, 2.5th and 97.5th percentile values were computed and compared with their RCVs. The distributions were assessed for normality using the Kolmogorov-Smirnov test. Most of the estimated limits were larger than the corresponding RCVs and, furthermore, with notable differences across the groups. Patients in the emergency care group usually demonstrated larger delta percent values than those in the other groups. None of the distributions of the percent differences passed tests of normality when subjected to Kolmogorov-Smirnov analysis. Comparison of estimated RCVs and real-world patient data revealed the pitfalls of applying RCVs in clinical laboratories. Laboratory managers should be aware of the limitations of RCVs and exercise caution when using them. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoenig, M.; Elsen, Y.V.; Cauter, R.V.
The progressive degradation of the pyrolytic graphite surface of atomizers provides variable and misleading results of molybdenum peak-height measurements. The changes in the peak shapes produce no analytical problems during the lifetime of the atomizer (approx.300 firings) when integrated absorbance (A.s signals) is considered and the possible base-line drifts are controlled. This was demonstrated on plant samples mineralized by simple digestion with a mixture of HNO/sub 3/ and H/sub 2/O/sub 2/. The value of this method was assessed by comparison with a standard dry oxidation method and by molybdenum determination in National Bureau of Standards reference plant samples. The relativemore » standard deviations (n = 5) of the full analytical procedure do not exceed 7%. 13 references, 3 figures, 3 tables.« less
[Comparison of refraction with or without cycloplegia using Retinomax® or Plusoptix® devices].
Bui Quoc, E; Guilmin Crepon, S; Tinguely, S; Lavallee, G; Busquet, G; Angot, M; Vera, L
2017-03-01
To evaluate the refraction in children measured with Plusoptix ® without cycloplegia vs. Retinomax ® apparatus with cycloplegia. Measure of refraction with Plusoptix ® in children>1year old referred for systematic vision screening, then measurement after cycloplegia with cyclopentolate by the Retinomax ® device. Thirty-three children were included, i.e. 66eyes. Mean age was 40.7months (minimum 12; maximum 114). The Spearman correlation coefficient for the spherical equivalent was 0.52 (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=moderate correlation). The Spearman correlation coefficient was 0.73 for astigmatism (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=strong correlation). The Plusoptix ® sensitivity for measurement of refraction was 57%, 43% and 43% respectively for spherical equivalent, sphere and astigmatism. The correlation of astigmatism values is strong, whereas the correlation of sphere values is moderate. Plusoptix ® seems to be unable to measure the exact refraction, because there is too large a dispersion of refraction measurements with Plusoptix ® , compared to the exact refraction measured with the Retinomax ® . Moreover, the sensitivity of Plusoptix ® is low. Cycloplegic refraction remains indispensable in children. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Initial comparison of single cylinder Stirling engine computer model predictions with test results
NASA Technical Reports Server (NTRS)
Tew, R. C., Jr.; Thieme, L. G.; Miao, D.
1979-01-01
A NASA developed digital computer code for a Stirling engine, modelling the performance of a single cylinder rhombic drive ground performance unit (GPU), is presented and its predictions are compared to test results. The GPU engine incorporates eight regenerator/cooler units and the engine working space is modelled by thirteen control volumes. The model calculates indicated power and efficiency for a given engine speed, mean pressure, heater and expansion space metal temperatures and cooler water inlet temperature and flow rate. Comparison of predicted and observed powers implies that the reference pressure drop calculations underestimate actual pressure drop, possibly due to oil contamination in the regenerator/cooler units, methane contamination in the working gas or the underestimation of mechanical loss. For a working gas of hydrogen, the predicted values of brake power are from 0 to 6% higher than experimental values, and brake efficiency is 6 to 16% higher, while for helium the predicted brake power and efficiency are 2 to 15% higher than the experimental.
Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency.
LaRue, Nicole; Kahn, Maria; Murray, Marjorie; Leader, Brandon T; Bansil, Pooja; McGray, Sarah; Kalnoky, Michael; Zhang, Hao; Huang, Huiqiang; Jiang, Hui; Domingo, Gonzalo J
2014-10-01
A barrier to eliminating Plasmodium vivax malaria is inadequate treatment of infected patients. 8-Aminoquinoline-based drugs clear the parasite; however, people with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk for hemolysis from these drugs. Understanding the performance of G6PD deficiency tests is critical for patient safety. Two quantitative assays and two qualitative tests were evaluated. The comparison of quantitative assays gave a Pearson correlation coefficient of 0.7585 with significant difference in mean G6PD activity, highlighting the need to adhere to a single reference assay. Both qualitative tests had high sensitivity and negative predictive value at a cutoff G6PD value of 40% of normal activity if interpreted conservatively and performed under laboratory conditions. The performance of both tests dropped at a cutoff level of 45%. Cytochemical staining of specimens confirmed that heterozygous females with > 50% G6PD-deficient cells can seem normal by phenotypic tests. © The American Society of Tropical Medicine and Hygiene.
Cusack, Lara; Field, Cara L; Hoopes, Lisa; McDermott, Alexa; Clauss, Tonya
2016-06-01
Though one of the most widely kept elasmobranchs in human care, the cownose ray (CNR; Rhinoptera bonasus ), remains a species with minimal published information on hematologic reference intervals. As part of a larger study investigating the health and nutrition of the CNR, this study established a preliminary data set of plasma chemistry and hematology values specific to animals recently caught from the wild and compared this data set (intake sample) to values obtained following a period of quarantine (27-40 days) in an aquarium (exit sample). Blood samples were collected from 47 wild female (n = 46) and male (n = 1) CNR caught in pound nets off the coast of North Carolina and South Carolina. Differences between intake and exit values were analyzed. Due to the preponderance of female animals, data were not analyzed for sex differences. Plasma biochemical profiles were performed and analyzed. A select number of complete blood cell counts were performed (n = 24 from 12 animals). Statistically significant differences (P < 0.05) specific to time of sampling were determined for packed cell volume, total solids, blood urea nitrogen, sodium, chloride, potassium, phosphorus, cholesterol, glucose, and aspartate aminotransferase. Values reported are a significant expansion on the existing limited data for CNRs and will serve as a reference for health assessment of individuals both in the wild and in exhibit populations.
Ram, E; Marcus, O; Joubran, S; Abdo, B; Asal, N R
2013-12-01
Lack of published data. Absence of Ethnic specific data. Lack of focus on obesity prevention in Arab schools. First set of data on obesity for Arab children. Data will be used as reference data. Alert health/school official for intervention. Objective The objective is to produce the first set of obesity prevalence data and use the data as reference values of body mass index (BMI) trends for Arab children in Israel and compare with Jewish and international data. Methods A prevalence study was carried out in 2009 in which 4130 children aged 6-12, were selected from eight Arab sector schools representing the Nazareth Municipality. Height, weight and BMI measurements were obtained and presented by age, mean age, size, weight, gender and percentile. Appropriate epidemiological and statistical methods used for comparison. Results The obesity and overweight prevalence rates in Arab children by age ranges from 0% to 2.6% and 0% to 11.2%, respectively. Comparison with international and Jewish data revealed differences in almost all age groups but higher rates in Arabs, especially boys. Discussion The higher rates/trends in Arab children may be explained by more Arab women entering the workforce, increase in single-parent families and changes in food and physical activity environments. Conclusion Based on our data, we recommend either an ethnic-specific BMI reference curves and/or inclusion of Arab data in the Israeli data system. Research need to focus on reasons for the increase and interventions to reverse/slow the trend. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.
NASA Astrophysics Data System (ADS)
Power, O.; Solve, S.; Chayramy, R.; Stock, M.
2012-01-01
As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Kutelia, E. R.; Dzigrashvili, T. A.; Kukava, T. G.; Darsavelidze, G. Sh.; Kurashvili, I. R.; Riedel, H.; Donth, B.
2017-02-01
The present research is dealing with the comparative study of inelastic/elastic behavior of reference ˜12%Cr steel ZL3 and three new trial steels ZU1, ZU2, ZU3, with different ratio of alloying elements and equal content of Cr, using internal friction measurements. The samples were examined in "as-received" condition and after additional electric current tempering at 700˚C under different fixed external mechanical tensions. The values of deformation critical amplitudes for dislocation breakaway (ɛ1) and for microplastic deformation beginning (ɛ2) were determined in addition to the activation energies of relaxation processes in the investigated steels. It is shown that all the three trial steel samples in "as-received" condition exhibit considerably higher values of ɛ2 in comparison to those of reference ZL3 steel. Among them the ZU3 steel has the highest values of ɛ1 and ɛ2, and demonstrates the visible (˜40%) increase in strength characteristics at elevated temperatures (600÷750˚C), achieved by the additional electric current tempering under mechanical tension.
The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron; Sengupta, Manajit; Andreas, Afshin
2016-06-02
This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturersmore » are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.« less
Steevens, Jeffery A.; Baumann, Paul C.; Jones, Susan B.
1996-01-01
β-Adrenoceptors (βARs) and muscarinic cholinergic receptors were measured in brain, gill, and heart tissues of brown bullhead catfish exposed to polycyclic aromatic hydrocarbons in the Black River, Ohio, USA, and were compared to values from Old Woman Creek, Ohio, a reference site. A decreased number of βARs were found in the gill from Black River fish, possibly indicating a compensatory response subsequent to chemical stress.
NASA Astrophysics Data System (ADS)
Antón, M.; Loyola, D.; Román, R.; Vömel, H.
2015-03-01
The main goal of this paper is to validate the total water vapour column (TWVC) measured by the Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensor and generated using the GOME Data Processor (GDP) retrieval algorithm developed by the German Aerospace Centre (DLR). For this purpose, spatially and temporally collocated TWVC data from highly accurate sounding measurements for the period January 2009-May 2014 at six sites are used. These balloon-borne data are provided by the GCOS Reference Upper-Air Network (GRUAN). The correlation between GOME-2 and sounding TWVC data is reasonably good (determination coefficient, R2, of 0.89) when all available radiosondes (1400) are employed in the inter-comparison. When cloud-free cases (544) are selected by means of the satellite cloud fraction (CF < 5%), the correlation exhibits a remarkable improvement (R2 ~ 0.95). Nevertheless, the analysis of the relative differences between GOME-2 and GRUAN data shows a mean absolute bias error (weighted with the combined uncertainty derived from the estimated errors of both data sets) of 15% for all-sky conditions (9% for cloud-free cases). These results evidence a notable bias in the satellite TWVC data against the reference balloon-borne measurements, partially related to the cloudy conditions during the satellite overpass. The detailed analysis of the influence of cloud properties - CF, cloud top albedo (CTA) and cloud top pressure (CTP) - on the satellite-sounding differences reveals, as expected, a large effect of clouds in the GOME-2 TWVC data. For instance, the relative differences exhibit a large negative dependence on CTA, varying from -6 to -23% when CTA rises from 0.3 to 0.8. Furthermore, the satellite-sounding TWVC differences show a strong dependence on the satellite solar zenith angle (SZA) for values above 50°. Hence the smallest relative differences found in this satellite-sounding comparison are achieved for those cloud-free cases with satellite SZA below 50°. Finally, the relative differences also show a negative dependence on the reference TWVC values, e.g. changing from +10% (TWVC below 10 mm) to -10% (TWVC above 40 mm) when cloud-free conditions with SZA below 50° are selected. Overall, relative differences within ±10% with respect to reference sounding data for a large range of TWVC values can be considered as a good result for satellite retrievals.
NASA Astrophysics Data System (ADS)
Nel, R.; Barrera-Figueroa, S.; Dobrowolska, D.; Defilippo Soares, Z. M.; Maina, A. K.; Hof, C.
2016-01-01
This is the final report of the AFRIMETS.AUV-S1 comparison of the pressure sensitivity, modulus and phase, of LS2aP microphones in the frequency range 1 Hz to 31.5 kHz in accordance with IEC 61094-2. Six national metrology institutes from three different regional metrology organisations participated in the comparison for which two LS2aP microphones were circulated simultaneously to all the participants in a hybrid-star configuration. The comparison reference values were calculated as the weighted mean for modulus and phase for each individual microphone. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.
2016-01-01
The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Henry, M J; Pasco, J A; Seeman, E; Nicholson, G C; Sanders, K M; Kotowicz, M A
2001-01-01
Fracture risk is determined by bone mineral density (BMD). The T-score, a measure of fracture risk, is the position of an individual's BMD in relation to a reference range. The aim of this study was to determine the magnitude of change in the T-score when different sampling techniques were used to produce the reference range. Reference ranges were derived from three samples, drawn from the same region: (1) an age-stratified population-based random sample, (2) unselected volunteers, and (3) a selected healthy subset of the population-based sample with no diseases or drugs known to affect bone. T-scores were calculated using the three reference ranges for a cohort of women who had sustained a fracture and as a group had a low mean BMD (ages 35-72 yr; n = 484). For most comparisons, the T-scores for the fracture cohort were more negative using the population reference range. The difference in T-scores reached 1.0 SD. The proportion of the fracture cohort classified as having osteoporosis at the spine was 26, 14, and 23% when the population, volunteer, and healthy reference ranges were applied, respectively. The use of inappropriate reference ranges results in substantial changes to T-scores and may lead to inappropriate management.
Lazar, Cosmin; Gatto, Laurent; Ferro, Myriam; Bruley, Christophe; Burger, Thomas
2016-04-01
Missing values are a genuine issue in label-free quantitative proteomics. Recent works have surveyed the different statistical methods to conduct imputation and have compared them on real or simulated data sets and recommended a list of missing value imputation methods for proteomics application. Although insightful, these comparisons do not account for two important facts: (i) depending on the proteomics data set, the missingness mechanism may be of different natures and (ii) each imputation method is devoted to a specific type of missingness mechanism. As a result, we believe that the question at stake is not to find the most accurate imputation method in general but instead the most appropriate one. We describe a series of comparisons that support our views: For instance, we show that a supposedly "under-performing" method (i.e., giving baseline average results), if applied at the "appropriate" time in the data-processing pipeline (before or after peptide aggregation) on a data set with the "appropriate" nature of missing values, can outperform a blindly applied, supposedly "better-performing" method (i.e., the reference method from the state-of-the-art). This leads us to formulate few practical guidelines regarding the choice and the application of an imputation method in a proteomics context.
A comparison of model short-range forecasts and the ARM Microbase data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hnilo, J J
2006-09-22
For the fourth quarter ARM metric we will make use of new liquid water data that has become available, and called the 'Microbase' value added product (referred to as OBS, within the text) at three sites: the North Slope of Alaska (NSA), Tropical West Pacific (TWP) and the Southern Great Plains (SGP) and compare these observations to model forecast data. Two time periods will be analyzed March 2000 for the SGP and October 2004 for both TWP and NSA. The Microbase data have been averaged to 35 pressure levels (e.g., from 1000hPa to 100hPa at 25hPa increments) and time averagedmore » to 3hourly data for direct comparison to our model output.« less
Xu, Jing; Liu, Xiaofei; Wang, Yutian
2016-08-05
Parallel factor analysis is a widely used method to extract qualitative and quantitative information of the analyte of interest from fluorescence emission-excitation matrix containing unknown components. Big amplitude of scattering will influence the results of parallel factor analysis. Many methods of eliminating scattering have been proposed. Each of these methods has its advantages and disadvantages. The combination of symmetrical subtraction and interpolated values has been discussed. The combination refers to both the combination of results and the combination of methods. Nine methods were used for comparison. The results show the combination of results can make a better concentration prediction for all the components. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Villarini, Gabriele; Khouakhi, Abdou; Cunningham, Evan
2017-12-01
Daily temperature values are generally computed as the average of the daily minimum and maximum observations, which can lead to biases in the estimation of daily averaged values. This study examines the impacts of these biases on the calculation of climatology and trends in temperature extremes at 409 sites in North America with at least 25 years of complete hourly records. Our results show that the calculation of daily temperature based on the average of minimum and maximum daily readings leads to an overestimation of the daily values of 10+ % when focusing on extremes and values above (below) high (low) thresholds. Moreover, the effects of the data processing method on trend estimation are generally small, even though the use of the daily minimum and maximum readings reduces the power of trend detection ( 5-10% fewer trends detected in comparison with the reference data).
Zeman, Kirby L; Wu, Jihong; Donaldson, Scott H; Bennett, William D
2013-04-01
Quantification of particle deposition in the lung by gamma scintigraphy requires a reference image for location of regions of interest (ROIs) and normalization to lung thickness. In various laboratories, the reference image is made by a transmission scan ((57)Co or (99m)Tc) or gas ventilation scan ((133)Xe or (81)Kr). There has not been a direct comparison of measures from the two methods. We compared (99m)Tc transmission scans to (133)Xe equilibrium ventilation scans as reference images for 38 healthy subjects and 14 cystic fibrosis (CF) patients for their effects on measures of regional particle deposition: the central-to-peripheral ratio of lung counts (C/P); and ROI area versus forced vital capacity. Whole right lung ROI was based on either an isocontour threshold of three times the soft tissue transmission (TT) or a threshold of 20% of peak xenon ventilation counts (XV). We used a central ROI drawn to 50% of height and of width of the whole right lung ROI and placed along the left lung margin and centered vertically. In general, the correlation of normalized C/P (nC/P) between the two methods was strong. However, the value of nC/P was significantly smaller for the XV method than the TT method. Regression equations for the relationship of nC/P between the two methods were, for healthy subjects, y=0.75x+0.61, R(2)=0.64 using rectangular ROIs and y=0.76x+0.45, R(2)=0.66 using isocontour ROIs; and for CF patients, y=0.94x+0.46, R(2)=0.43 and y=0.85x+0.42, R(2)=0.41, respectively. (1) A transmission scan with an isocontour outline in combination with a rectangular central region to define the lung borders may be more useful than a ventilation scan. (2) Close correlation of nC/Ps measured by transmission or gas ventilation should allow confident comparison of values determined by the two methods.
Schaly, Bryan; Kempe, Jeff; Venkatesan, Varagur; Mitchell, Sylvia; Battista, Jerry J
2017-11-01
During radiation therapy of head and neck cancer, the decision to consider replanning a treatment because of anatomical changes has significant resource implications. We developed an algorithm that compares cone-beam computed tomography (CBCT) image pairs and provides an automatic alert as to when remedial action may be required. Retrospective CBCT data from ten head and neck cancer patients that were replanned during their treatment was used to train the algorithm on when to recommend a repeat CT simulation (re-CT). An additional 20 patients (replanned and not replanned) were used to validate the predictive power of the algorithm. CBCT images were compared in 3D using the gamma index, combining Hounsfield Unit (HU) difference with distance-to-agreement (DTA), where the CBCT study acquired on the first fraction is used as the reference. We defined the match quality parameter (MQP x ) as a difference between the x th percentiles of the failed-pixel histograms calculated from the reference gamma comparison and subsequent comparisons, where the reference gamma comparison is taken from the first two CBCT images acquired during treatment. The decision to consider re-CT was based on three consecutive MQP values being less than or equal to a threshold value, such that re-CT recommendations were within ±3 fractions of the actual re-CT order date for the training cases. Receiver-operator characteristic analysis showed that the best trade-off in sensitivity and specificity was achieved using gamma criteria of 3 mm DTA and 30 HU difference, and the 80 th percentile of the failed-pixel histogram. A sensitivity of 82% and 100% was achieved in the training and validation cases, respectively, with a false positive rate of ~30%. We have demonstrated that gamma analysis of CBCT-acquired anatomy can be used to flag patients for possible replanning in a manner consistent with local clinical practice guidelines. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Shah, Sachita P; Penn, Kevin; Kaplan, Stephen J; Vrablik, Michael; Jablonowski, Karl; Pham, Tam N; Reed, May J
2018-04-14
Frailty is linked to poor outcomes in older patients. We prospectively compared the utility of the picture-based Clinical Frailty Scale (CFS9), clinical assessments, and ultrasound muscle measurements against the reference FRAIL scale in older adult trauma patients in the emergency department (ED). We recruited a convenience sample of adults 65 yrs. or older with blunt trauma and injury severity scores <9. We queried subjects (or surrogates) on the FRAIL scale, and compared this to: physician-based and subject/surrogate-based CFS9; mid-upper arm circumference (MUAC) and grip strength; and ultrasound (US) measures of muscle thickness (limbs and abdominal wall). We derived optimal diagnostic thresholds and calculated performance metrics for each comparison using sensitivity, specificity, predictive values, and area under receiver operating characteristic curves (AUROC). Fifteen of 65 patients were frail by FRAIL scale (23%). CFS9 performed well when assessed by subject/surrogate (AUROC 0.91 [95% CI 0.84-0.98] or physician (AUROC 0.77 [95% CI 0.63-0.91]. Optimal thresholds for both physician and subject/surrogate were CFS9 of 4 or greater. If both physician and subject/surrogate provided scores <4, sensitivity and negative predictive value were 90.0% (54.1-99.5%) and 95.0% (73.1-99.7%). Grip strength and MUAC were not predictors. US measures that combined biceps and quadriceps thickness showed an AUROC of 0.75 compared to the reference standard. The ED needs rapid, validated tools to screen for frailty. The CFS9 has excellent negative predictive value in ruling out frailty. Ultrasound of combined biceps and quadriceps has modest concordance as an alternative in trauma patients who cannot provide a history. Copyright © 2017 Elsevier Inc. All rights reserved.
Reference values for CSF outflow resistance and intracranial pressure in healthy elderly.
Malm, Jan; Jacobsson, Johan; Birgander, Richard; Eklund, Anders
2011-03-08
The intracranial pressure (ICP) and CSF outflow resistance (R(out)) are essential to describe the dynamics of the CSF system. R(out) affects ICP, pulse amplitudes, CSF absorption, and the compliance of the system. The objective of this study was to determine the reference values in healthy elderly subjects. Elderly people (60-82 years), who considered themselves healthy, were recruited through an advertisement in the local newspaper. All were evaluated with a 3-T MRI. Subjects were eligible if they did not have any psychiatric or neurologic disorder or signs of advanced atherosclerotic disease. CSF resting pressure (ICP) and R(out) were determined by a constant pressure infusion method with the patient in the supine position. The study population consisted of 40 subjects (mean age 70 years; 23 women). The median ICP was 11.6 mm Hg (15.8 cmH(2)O) and the reference interval was ICP 7.8-14.3 mm Hg (10.6-19.4 cmH(2)O) (defined as 5th to 95th percentiles). The median R(out) was 8.6 mm Hg/mL/min. The variation in R(out) was large and not normally distributed. The 90th percentile of R(out) was 17.4 mm Hg/mL/min. This study reports reference values for ICP and R(out) and should be used for comparison when investigating disorders with suspected CSF dynamic disturbances in the elderly. ICP was in the same range as that reported in the young and middle-aged. The upper limit of R(out) was higher than previously believed to be the upper limit of normal for this age group.
Díaz Bonilla, Edilberto; Torres Galvis, Claudia L; Gómez Campos, Rossana; de Arruda, Miguel; Pacheco Carrillo, Jaime; Cossio Bolaños, Marco
2018-04-01
There is increasing concern over the study of physical growth in different regions of the world, although altitude is not considered an adjustment factor. Compare physical growth variables and body mass index (BMI) patterns with the Centers for Disease Control and Prevention (CDC) 2012 reference data and develop percentiles for children and adolescents. School children living at moderate altitude in Bogotá (Colombia) were studied. Their weight and height were evaluated and their BMI was calculated. Anthropometric variables were compared against reference data of the CDC-2012, Brazil, Peru and Argentina. Curves were constructed using the least mean square (LMS) method. A total of 2241 school children (1159 girls) aged 6.0 to 17.9 years were included. There were no significant differences in weight and BMI in 6 to 8 year-olds relative to CDC-2012 reference data; in 9 to 17 year-old children, however, this sample evidenced lower values in terms of weight and BMI as compared to those of the CDC-2012. As far as height is concerned, in both sexes, values were lower than those of the CDC-2012. Comparisons against the regional curves of Argentina, Peru and Brazil yielded relatively similar results, with the exception of girls' BMI, as 13 to 17 year-old girls exhibited lower values. Growth variables of school children were lower relative to the CDC-2012 reference data. There were slight discrepancies in physical growth and BMI in relation to the curves of Argentina, Peru and Brazil. Curves were constructed to evaluate growth in school children living at moderate altitude in Colombia. Sociedad Argentina de Pediatría.
Comparison of the NIST and PTB Air-Kerma Standards for Low-Energy X-Rays.
O'Brien, Michelle; Bueermann, Ludwig
2009-01-01
A comparison has been made of the air-kerma standards for low-energy x rays at the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). The comparison involved a series of measurements at the PTB and the NIST using the air-kerma standards and two NIST reference-class transfer ionization chamber standards. Results are presented for the reference radiation beam qualities in the range from 25 kV to 50 kV for low energy x rays, including the techniques used for mammography dose traceability. The tungsten generated reference radiation qualities, between 25 kV and 50 kV used for this comparison, are new to NIST; therefore this comparison will serve as the preliminary comparison for NIST and a verification of the primary standard correction factors. The mammography comparison will repeat two previously unpublished comparisons between PTB and NIST. The results show the standards to be in reasonable agreement within the standard uncertainty of the comparison of about 0.4 %.
NASA Astrophysics Data System (ADS)
Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pritchett, Jeanita; Pabello, Guiomar; Avila Calderon, Marco A.; Balderas, Miryan; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Monteiro, Tânia; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Peignaux, Maryline; Kawaguchi, Migaku; Bei, Xu; Can, Quan; Nammoonnoy, Jintana; Schild, Katrin; Ohlendorf, Rüdiger; Henrion, Andre; Ceyhan Gören, Ahmet; Yılmaz, Hasibe; Bilsel, Mine; Konopelko, L.; Krylov, A.; Lopushanskaya, E.
2018-01-01
Glucose and creatinine are two of the most frequently measured substances in human blood/serum for assessing the health status of individuals. Because of their clinical significance, CCQM-K11 glucose in human serum and CCQM-K12 creatinine in human serum were the fourth and fifth key comparisons (KCs) performed by the Organic Analysis Working Group (OAWG). These KCs were conducted in parallel and were completed in 2001. The initial subsequent KCs for glucose, CCQM-K11.1, and creatinine, CCQM-K12.1, were completed in 2005. Measurements for the next KCs for these two measurands, CCQM-K11.2 and CCQM-K12.2, were completed in 2013. While designed as subsequent KCs, systematic discordances between the participants' and the anchor institution's results in both comparisons lead the OAWG to request reference results from two experienced laboratories that had participated in the 2001 comparisons. Based on the totality of the available information, the OAWG converted both CCQM-K11.2 and CCQM-K12.2 to 'Track C' KCs where the key comparison reference value is estimated by consensus. These comparisons highlighted that carrying out comparisons for complex chemical measurements and expecting to be able to treat them under the approaches used for formal CIPM subsequent comparisons is not an appropriate strategy. The approach used here is a compromise to gain the best value from the comparison; it is not an approach that will be used in the future. Instead, the OAWG will focus on Track A and Track C comparisons that are treated as stand-alone entities. Participation in CCQM-K11.2 demonstrates a laboratory's capabilities to measure a polar (pKow > 2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (0.1 mg/g to 10 mg/g). Participation in CCQM-K12.2 demonstrates capabilities to measure similar classes of metabolites at relatively low concentrations (1 μg/g to 30 μg/g). The capabilities required for the analysis of complex biological matrices include sample preparation (protein precipitation, extraction, derivatization), gas chromatographic (GC) or liquid chromatographic (LC) separation, and quantification using an isotope dilution mass spectrometry (IDMS) approach. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Wunderli, S; Fortunato, G; Reichmuth, A; Richard, Ph
2003-06-01
A new method to correct for the largest systematic influence in mass determination-air buoyancy-is outlined. A full description of the most relevant influence parameters is given and the combined measurement uncertainty is evaluated according to the ISO-GUM approach [1]. A new correction method for air buoyancy using an artefact is presented. This method has the advantage that only a mass artefact is used to correct for air buoyancy. The classical approach demands the determination of the air density and therefore suitable equipment to measure at least the air temperature, the air pressure and the relative air humidity within the demanded uncertainties (i.e. three independent measurement tasks have to be performed simultaneously). The calculated uncertainty is lower for the classical method. However a field laboratory may not always be in possession of fully traceable measurement systems for these room climatic parameters.A comparison of three approaches applied to the calculation of the combined uncertainty of mass values is presented. Namely the classical determination of air buoyancy, the artefact method, and the neglecting of this systematic effect as proposed in the new EURACHEM/CITAC guide [2]. The artefact method is suitable for high-precision measurement in analytical chemistry and especially for the production of certified reference materials, reference values and analytical chemical reference materials. The method could also be used either for volume determination of solids or for air density measurement by an independent method.
Wadwa, R Paul; Laffel, Lori M; Shah, Viral N; Garg, Satish K
2018-06-01
Frequent use of continuous glucose monitoring (CGM) systems is associated with improved glycemic outcomes in persons with diabetes, but the need for calibrations and sensor insertions are often barriers to adoption. In this study, we evaluated the performance of G6, a sixth-generation, factory-calibrated CGM system specified for 10-day wear. The study enrolled participants of ages 6 years and up with type 1 diabetes or insulin-treated type 2 diabetes at 11 sites in the United States. Participation involved one sensor wear period of up to 10 days. Adults wore the system on the abdomen; youth of ages 6-17 years could choose to wear it on the abdomen or upper buttocks. Clinic sessions for frequent comparison with reference blood glucose measurements took place on days 1, 4-5, 7, and/or 10. Participants of ages 13 years and up underwent purposeful supervised glucose manipulation during in-clinic sessions. During the study, participants calibrated the systems once daily. However, analysis was performed on glucose values that were derived from reprocessed raw sensor data, independently of self-monitored blood glucose values used for calibration. Reprocessing used assigned sensor codes and a factory-calibration algorithm. Performance evaluation included the proportion of CGM values that were within ±20% of reference glucose values >100 mg/dL or within ±20 mg/dL of reference glucose values ≤100 mg/dL (%20/20), the analogous %15/15, and the mean absolute relative difference (MARD, expressed as a percentage) between temporally matched CGM and reference values. Data from 262 study participants (21,569 matched CGM reference pairs) were analyzed. The overall %15/15, %20/20, and MARD were 82.4%, 92.3%, and 10.0%, respectively. Matched pairs from 134 adults and 128 youth of ages 6-17 years were similar with respect to %20/20 (92.4% and 91.9%) and MARD (9.9% and 10.1%). Overall %20/20 values on days 1 and 10 of sensor wear were 88.6% and 90.6%, respectively. The system's "Urgent Low Soon" (predictive of hypoglycemia within 20 min) hypoglycemia alert was correctly provided 84% of the time within 30 min before impending biochemical hypoglycemia (<70 mg/dL). The 10-day sensor survival rate was 87%. The new factory-calibrated G6 real-time CGM system provides accurate readings for 10 days and removes several clinical barriers to broader CGM adoption.
SIM key comparison for luminous flux. SIM.PR-K4
NASA Astrophysics Data System (ADS)
Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.
2016-01-01
In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.
2015-01-01
A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Final report on the Seventh International Comparison of Absolute Gravimeters (ICAG 2005)
Jiang, Z.; Francis, O.; Vitushkin, L.; Palinkas, V.; Germak, A.; Becker, M.; D'Agostino, G.; Amalvict, M.; Bayer, R.; Bilker-Koivula, M.; Desogus, S.; Faller, J.; Falk, R.; Hinderer, J.; Gagnon, C.; Jakob, T.; Kalish, E.; Kostelecky, J.; Lee, C.; Liard, J.; Lokshyn, Y.; Luck, B.; Makinen, J.; Mizushima, S.; Le, Moigne N.; Origlia, C.; Pujol, E.R.; Richard, P.; Robertsson, L.; Ruess, D.; Schmerge, D.; Stus, Y.; Svitlov, S.; Thies, S.; Ullrich, C.; Van Camp, M.; Vitushkin, A.; Ji, W.; Wilmes, H.
2011-01-01
The Bureau International des Poids et Mesures (BIPM), S??vres, France, hosted the 7th International Comparison of Absolute Gravimeters (ICAG) and the associated Relative Gravity Campaign (RGC) from August to September 2005. ICAG 2005 was prepared and performed as a metrological pilot study, which aimed: To determine the gravity comparison reference values; To determine the offsets of the absolute gravimeters; and As a pilot study to accumulate experience for the CIPM Key Comparisons. This document presents a complete and extensive review of the technical protocol and data processing procedures. The 1st ICAG-RGC comparison was held at the BIPM in 1980-1981 and since then meetings have been organized every 4 years. In this paper, we present an overview of how the meeting was organized, the conditions of BIPM gravimetric sites, technical specifications, data processing strategy and an analysis of the final results. This 7th ICAG final report supersedes all previously published reports. Readings were obtained from participating instruments, 19 absolute gravimeters and 15 relative gravimeters. Precise levelling measurements were carried out and all measurements were performed on the BIPM micro-gravity network which was specifically designed for the comparison. ?? 2011 BIPM & IOP Publishing Ltd.
Kelishadi, Roya; Gouya, Mohammad Mehdi; Ardalan, Gelayol; Hosseini, Mohsen; Motaghian, Molouk; Delavari, Alireza; Majdzadeh, Reza; Heidarzadeh, Abtin; Mahmoud-Arabi, Minou Sadat; Riazi, Mohammad Mehdi
2007-06-01
The Objective of the present study is to develop the first age- and gender-specific reference curves for waist and hip circumferences in an Asian population of youths. This cross-sectional population survey was conducted in 2003-04 on a nationally representative sample of 21111 school-students living in urban (84.6%) and rural (15.4%) areas of 23 provinces in Iran. After anthropometric measurements, smoothed reference curves for waist and hip circumference (WC, HiC) and waist-to-hip ratio (WHR) were developed by the LMS method. In both genders, WC and HiC percentile values increased with age. For girls, the 50th to 95th percentile curves for WC had a sharp increase between 8 and 13 years and 11-15 years, respectively, and began to plateau after this age, whereas for boys, these curves had a persistent and less sharp increase with age, until the age of 18 years. The WHR curves of girls decreased with age until 15 years and began to plateau thereafter, whereas for boys the 25th to 95th curves had a plateau pattern. Comparison of the current reference curves with the British ones showed that in boys, the 5th and 50th percentile curves were similar in both studies, but the 95th percentile curve of our study was higher than the British curves. For girls, the 5th percentile curves of both studies were similar, but the 50th and 95th percentile curves of our study were higher than the British ones. These curves represent the first childhood WC, HiC and WHR reference curves obtained in Asia. These curves can provide baseline data for analysis of time trends, as well as for international comparisons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daleu, C. L.; Plant, R. S.; Woolnough, S. J.
Here, as part of an international intercomparison project, a set of single-column models (SCMs) and cloud-resolving models (CRMs) are run under the weak-temperature gradient (WTG) method and the damped gravity wave (DGW) method. For each model, the implementation of the WTG or DGW method involves a simulated column which is coupled to a reference state defined with profiles obtained from the same model in radiative-convective equilibrium. The simulated column has the same surface conditions as the reference state and is initialized with profiles from the reference state. We performed systematic comparison of the behavior of different models under a consistentmore » implementation of the WTG method and the DGW method and systematic comparison of the WTG and DGW methods in models with different physics and numerics. CRMs and SCMs produce a variety of behaviors under both WTG and DGW methods. Some of the models reproduce the reference state while others sustain a large-scale circulation which results in either substantially lower or higher precipitation compared to the value of the reference state. CRMs show a fairly linear relationship between precipitation and circulation strength. SCMs display a wider range of behaviors than CRMs. Some SCMs under the WTG method produce zero precipitation. Within an individual SCM, a DGW simulation and a corresponding WTG simulation can produce different signed circulation. When initialized with a dry troposphere, DGW simulations always result in a precipitating equilibrium state. The greatest sensitivities to the initial moisture conditions occur for multiple stable equilibria in some WTG simulations, corresponding to either a dry equilibrium state when initialized as dry or a precipitating equilibrium state when initialized as moist. Multiple equilibria are seen in more WTG simulations for higher SST. In some models, the existence of multiple equilibria is sensitive to some parameters in the WTG calculations.« less
References for Haplotype Imputation in the Big Data Era
Li, Wenzhi; Xu, Wei; Li, Qiling; Ma, Li; Song, Qing
2016-01-01
Imputation is a powerful in silico approach to fill in those missing values in the big datasets. This process requires a reference panel, which is a collection of big data from which the missing information can be extracted and imputed. Haplotype imputation requires ethnicity-matched references; a mismatched reference panel will significantly reduce the quality of imputation. However, currently existing big datasets cover only a small number of ethnicities, there is a lack of ethnicity-matched references for many ethnic populations in the world, which has hampered the data imputation of haplotypes and its downstream applications. To solve this issue, several approaches have been proposed and explored, including the mixed reference panel, the internal reference panel and genotype-converted reference panel. This review article provides the information and comparison between these approaches. Increasing evidence showed that not just one or two genetic elements dictate the gene activity and functions; instead, cis-interactions of multiple elements dictate gene activity. Cis-interactions require the interacting elements to be on the same chromosome molecule, therefore, haplotype analysis is essential for the investigation of cis-interactions among multiple genetic variants at different loci, and appears to be especially important for studying the common diseases. It will be valuable in a wide spectrum of applications from academic research, to clinical diagnosis, prevention, treatment, and pharmaceutical industry. PMID:27274952
NASA Astrophysics Data System (ADS)
Apel, W. D.; Arteaga-Velázquez, J. C.; Bähren, L.; Bekk, K.; Bertaina, M.; Biermann, P. L.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Falcke, H.; Fuchs, B.; Gemmeke, H.; Grupen, C.; Haungs, A.; Heck, D.; Hiller, R.; Hörandel, J. R.; Horneffer, A.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Krömer, O.; Kuijpers, J.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Melissas, M.; Morello, C.; Nehls, S.; Oehlschläger, J.; Palmieri, N.; Pierog, T.; Rautenberg, J.; Rebel, H.; Roth, M.; Rühle, C.; Saftoiu, A.; Schieler, H.; Schmidt, A.; Schoo, S.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Weindl, A.; Wochele, J.; Zabierowski, J.; Zensus, J. A.
2016-02-01
LOPES was a digital antenna array detecting the radio emission of cosmic-ray air showers. The calibration of the absolute amplitude scale of the measurements was done using an external, commercial reference source, which emits a frequency comb with defined amplitudes. Recently, we obtained improved reference values by the manufacturer of the reference source, which significantly changed the absolute calibration of LOPES. We reanalyzed previously published LOPES measurements, studying the impact of the changed calibration. The main effect is an overall decrease of the LOPES amplitude scale by a factor of 2.6 ± 0.2, affecting all previously published values for measurements of the electric-field strength. This results in a major change in the conclusion of the paper 'Comparing LOPES measurements of air-shower radio emission with REAS 3.11 and CoREAS simulations' published by Apel et al. (2013) : With the revised calibration, LOPES measurements now are compatible with CoREAS simulations, but in tension with REAS 3.11 simulations. Since CoREAS is the latest version of the simulation code incorporating the current state of knowledge on the radio emission of air showers, this new result indicates that the absolute amplitude prediction of current simulations now is in agreement with experimental data.
Korshøj, Mette; Skotte, Jørgen H; Christiansen, Caroline S; Mortensen, Pelle; Kristiansen, Jesper; Hanisch, Christiana; Ingebrigtsen, Jørgen; Holtermann, Andreas
2014-01-01
The validity of inclinometer measurements by ActiGraph GT3X+ (AG) accelerometer, when analysed with the Acti4 customised software, was examined by comparison of inclinometer measurements with a reference system (TrakStar) in a protocol with standardised arm movements and simulated working tasks. The sensors were placed at the upper arm (distal to the deltoid insertion) and at the spine (level of T1-T2) on eight participants. Root mean square errors (RMSEs) values of inclination between the two systems were low for the slow- and medium-speed standardised arm movements and in simulated working tasks. Fast arm movements caused the inclination estimated by the AG to deviate from the reference measurements (RMSE values up to ∼10°). Furthermore, it was found that AG positioned at the upper arm provided inclination data without bias compared to the reference system. These findings indicate that the AG provides valid estimates of arm and upper body inclination in working participants. Being inexpensive, small, water-resistant and without wires, ActiGraph GT3X+ seems to be a valid mean for direct long-term field measurements of arm and trunk inclinations when analysed by the Acti4 customised software.
Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R
2015-10-01
Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.
Füchtmeier, B; May, R; Fierlbeck, J; Hammer, J; Nerlich, M
2006-01-01
A new humerus nail (Sirus) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed for testing. Three randomized groups were formed (n = 4 pairs). A bending moment of 7.5 Nm and a torsional moment of 8.3 Nm were applied in a test of five loading cycles to all intact bones. Loading was consistently initiated at the distal epiphysis. The consequent deformation at the distal epiphysis was continuously recorded. Then an osteotomy with a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one of each pair was stabilized with the Sirus proximal humerus nail. The other side was fixed with a reference implant. The following groups were created.: Group I: Sirus versus Proximal humerus nail (PHN) with spiral blade. Group II: Sirus versus PHILOS plate. Group III: Sirus versus 4.5 mm AO T-plate. The proximal humerus nail (Sirus) demonstrated significantly higher stiffness values than the reference implants for both bending and torsional load. The following values were recorded at a bending moment of 7.5 Nm: Sirus 14.2 mm, PHN 20.7 mm, PHILOS plate 28.1 mm, 4.5 AO T-plate 29.3 mm p < 0.0012). The values at 8.3 Nm torsional moment were: Sirus 8.5 degrees , PHN 12.3 degrees , PHILOS plate 16.4 degrees , 4.5 AO T-Platte 15.6 degrees (p < 0.002). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the fracture model presented here. Supplementary, the Sirus Nail showed higher stiffness values than the PHN. However, the latter are gaining in importance due to the possibility of minimal invasive implantation. Whether this will be associated with functional advantages requires further clinical investigation.
FFT swept filtering: a bias-free method for processing fringe signals in absolute gravimeters
NASA Astrophysics Data System (ADS)
Křen, Petr; Pálinkáš, Vojtech; Mašika, Pavel; Val'ko, Miloš
2018-05-01
Absolute gravimeters, based on laser interferometry, are widely used for many applications in geoscience and metrology. Although currently the most accurate FG5 and FG5X gravimeters declare standard uncertainties at the level of 2-3 μGal, their inherent systematic errors affect the gravity reference determined by international key comparisons based predominately on the use of FG5-type instruments. The measurement results for FG5-215 and FG5X-251 clearly showed that the measured g-values depend on the size of the fringe signal and that this effect might be approximated by a linear regression with a slope of up to 0.030 μGal/mV . However, these empirical results do not enable one to identify the source of the effect or to determine a reasonable reference fringe level for correcting g-values in an absolute sense. Therefore, both gravimeters were equipped with new measuring systems (according to Křen et al. in Metrologia 53:27-40, 2016. https://doi.org/10.1088/0026-1394/53/1/27 applied for FG5), running in parallel with the original systems. The new systems use an analogue-to-digital converter HS5 to digitize the fringe signal and a new method of fringe signal analysis based on FFT swept bandpass filtering. We demonstrate that the source of the fringe size effect is connected to a distortion of the fringe signal due to the electronic components used in the FG5(X) gravimeters. To obtain a bias-free g-value, the FFT swept method should be applied for the determination of zero-crossings. A comparison of g-values obtained from the new and the original systems clearly shows that the original system might be biased by approximately 3-5 μGal due to improperly distorted fringe signal processing.
Squeri, Angelo; Censi, Stefano; Reverberi, Claudio; Gaibazzi, Nicola; Baldelli, Marco; Binno, Simone Maurizio; Properzi, Enrico; Bosi, Stefano
2017-03-01
Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2 = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.
The use of biotic and abiotic components of Red Sea coastal areas as indicators of ecosystem health.
Omar, Wael A; Saleh, Yousef S; Marie, Mohamed-Assem S
2016-03-01
A biomonitoring study was conducted using some biotic (Pomadasys hasta and Lutjanus russellii fish) and abiotic (water and sediment) components of the Red Sea coast of Hodeida, Yemen Republic along two polluted sites (Al-Dawar beach and Urj village) in comparison to a reference site (Al-Nukhailah beach). The studied fish biomarkers included hepatosomatic index (HSI), condition factor (K), scaled mass index (SMI), catalase, glutathione-S-transferase (GST), malondialdehyde (MDA), total protein and albumin. In addition, metals (Fe, Cu, Zn, Pb and Cd) concentrations in water and sediment were measured and sediment pollution assessment was carried out using contamination factor (CF), geoaccumulation index (Igeo), pollution load index (PLI) and enrichment factor (EF). The studied metals concentration in water and sediment samples showed significant increase among the polluted sites in comparison to the reference site. Sediment pollution assessment generally confirmed that Urj village was the most contaminated site followed by Al-Dawar beach. Catalase, GST and MDA proved to be the most responsive biomarkers with increased values of GST and MDA at sites influenced by agricultural, urban and industrial activities while catalase, HSI, K, SMI, total protein and albumin showed the opposite trend. This study recommends monitoring of sediment Igeo and EF values as well as SMI, catalase, GST and MDA as sensitive indicators of different anthropogenic activities and their effects on aquatic ecosystems under complex and different gradients of metal pollution. In addition, P. hasta proved to be more sensitive towards the detected pollution condition.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-10-13
The diagnostic values of diffusion weighted imaging (DWI) and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73-0.85), 0.69 (0.61-0.77), and 0.81 (0.77-0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39-0.64), 0.88 (0.61-0.97), and 0.66 (0.62-0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18 F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18 F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18 F-FDG PET/CT had limited utility for preoperative N-staging.
Jibiri, Nnamdi N.
2016-01-01
In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hindered. The aim of the present study was to estimate the dose‐area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in Nigeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/minimum ratio ranged from 3 for thigh AP to 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18–17.16, and 0.25–28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB‐HPE reference values. The DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB‐HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose optimization implementation in Nigeria would lead to lower DAP value, especially in abdomen AP. The 75th percentile DAP distribution reported in this study could be taken as regional diagnostic reference level in the Southwestern Nigeria; however, a more extensive nationwide dose survey is required to establish national reference dose. PACS number(s): 87.53.Bn, 87.59.B PMID:27929511
Monitoring hydrofrac-induced seismicity by surface arrays - the DHM-Project Basel case study
NASA Astrophysics Data System (ADS)
Blascheck, P.; Häge, M.; Joswig, M.
2012-04-01
The method "nanoseismic monitoring" was applied during the hydraulic stimulation at the Deep-Heat-Mining-Project (DHM-Project) Basel. Two small arrays in a distance of 2.1 km and 4.8 km to the borehole recorded continuously for two days. During this time more than 2500 seismic events were detected. The method of the surface monitoring of induced seismicity was compared to the reference which the hydrofrac monitoring presented. The latter was conducted by a network of borehole seismometers by Geothermal Explorers Limited. Array processing provides a outlier resistant, graphical jack-knifing localization method which resulted in a average deviation towards the reference of 850 m. Additionally, by applying the relative localization master-event method, the NNW-SSE strike direction of the reference was confirmed. It was shown that, in order to successfully estimate the magnitude of completeness as well as the b-value at the event rate and detection sensibility present, 3 h segments of data are sufficient. This is supported by two segment out of over 13 h of evaluated data. These segments were chosen so that they represent a time during the high seismic noise during normal working hours in daytime as well as the minimum anthropogenic noise at night. The low signal-to-noise ratio was compensated by the application of a sonogram event detection as well as a coincidence analysis within each array. Sonograms allow by autoadaptive, non-linear filtering to enhance signals whose amplitudes are just above noise level. For these events the magnitude was determined by the master-event method, allowing to compute the magnitude of completeness by the entire-magnitude-range method provided by the ZMAP toolbox. Additionally, the b-values were determined and compared to the reference values. An introduction to the method of "nanoseismic monitoring" will be given as well as the comparison to reference data in the Basel case study.
Jibiri, Nnamdi N; Olowookere, Christopher J
2016-11-08
In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hin-dered. The aim of the present study was to estimate the dose-area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in Nigeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/ minimum ratio ranged from 3 for thigh AP to 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18-17.16, and 0.25-28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB-HPE reference values. The DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB-HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose optimization implementation in Nigeria would lead to lower DAP value, especially in abdomen AP. The 75th percentile DAP distribution reported in this study could be taken as regional diagnostic reference level in the Southwestern Nigeria; however, a more extensive nationwide dose survey is required to establish national reference dose. © 2016 The Authors.
Selectivity of similar compounds' identification using IR spectrometry: β-Lactam antibiotics
NASA Astrophysics Data System (ADS)
Sadlej-Sosnowska, Nina; Ocios, Agnieszka; Fuks, Leon
2006-07-01
The study aims to develop a reliable, quantitative method for positive identification or discrimination of a substance, when it is compared to a set of similar ones. In the course of the study a group of structurally related compounds, namely a set of β-lactam antimicrobial agents has been explored. Identification of a substance was based on the comparison of its spectrum with that of a reference material by using two functional algorithms. The algorithm based on the calculation of correlation coefficient between the first derivatives of the spectra has been proved more powerful than that using the original spectra. Then the results in a few spectral regions were likened. Limiting values were proposed for correlation coefficients that allow for qualification of a substance as identical to the reference one.
Munoz, Alexis R; Salsman, John M; Stein, Kevin D; Cella, David
2015-06-01
Health-related quality of life measures are common in oncology research, trials, and practice. Spiritual well-being has emerged as an important aspect of health-related quality of life and the Functional Assessment of Chronic Illness Therapy-Spiritual Well-Being; The 12-item Spiritual Well-Being Scale (FACIT-Sp-12) is the most widely used measure of spiritual well-being among those with cancer. However, there is an absence of reference values with which to facilitate the interpretation of scores in research and clinical practice. The objective of the current study was to provide FACIT-Sp-12 reference values from a representative sample of adult cancer survivors. As part of the American Cancer Society's Study of Cancer Survivors-II, a national cross-sectional study of cancer survivors (8864 survivors) completed questionnaires assessing demographic characteristics, clinical information, and the FACIT-Sp-12. Scores were calculated and summarized by FACIT-Sp-12 subscale and total scores across age, sex, race/ethnicity, time after treatment, and cancer type. Student t tests for independent samples found that women reported significantly higher FACIT-Sp-12 scores (P<.001). Analyses of variance found significant main effects for FACIT-Sp-12 scores by age (P<.01), race/ethnicity (P<.05), and cancer type (P<.001). Post hoc comparisons revealed that older adults (those aged 60-69 years and 70-79 years) and black non-Hispanic individuals reported the highest FACIT-Sp-12 scores compared with those aged 18 to 39 years (P<.05; Cohen d [an effect size used to indicate the standardized difference between 2 means], 0.20-0.50) and white non-Hispanic individuals (P<.05; Cohen d, 0.02-0.62), respectively. All other significant main effects were small in magnitude (effect size range, 0.001-0.032). These data will aid in the interpretation of the magnitude and meaning of FACIT-Sp-12 scores, and allow for comparisons of scores across studies. © 2015 American Cancer Society.
Thiele, Maja; Madsen, Bjørn Stæhr; Hansen, Janne Fuglsang; Detlefsen, Sönke; Antonsen, Steen; Krag, Aleksander
2018-04-01
Alcohol is the leading cause of cirrhosis and liver-related mortality, but we lack serum markers to detect compensated disease. We compared the accuracy of the Enhanced Liver Fibrosis test (ELF), the FibroTest, liver stiffness measurements (made by transient elastography and 2-dimensional shear-wave elastography), and 6 indirect marker tests in detection of advanced liver fibrosis (Kleiner stage ≥F3). We performed a prospective study of 10 liver fibrosis markers (patented and not), all performed on the same day. Patients were recruited from primary centers (municipal alcohol rehabilitation, n = 128; 6% with advanced fibrosis) and secondary health care centers (hospital outpatient clinics, n = 161; 36% with advanced fibrosis) in the Region of Southern Denmark from 2013 through 2016. Biopsy-verified fibrosis stage was used as the reference standard. The primary aim was to validate ELF in detection of advanced fibrosis in patients with alcoholic liver disease recruited from primary and secondary health care centers, using the literature-based cutoff value of 10.5. Secondary aims were to assess the diagnostic accuracy of ELF for significant fibrosis and cirrhosis and to determine whether combinations of fibrosis markers increase diagnostic yield. The ELF identified patients with advanced liver fibrosis with an area under the receiver operating characteristic curve (AUROC) of 0.92 (95% confidence interval 0.89-0.96); findings did not differ significantly between patients from primary vs secondary care (P = .917). ELF more accurately identified patients with advanced liver fibrosis than indirect marker tests, but ELF and FibroTest had comparable diagnostic accuracies (AUROC of FibroTest, 0.90) (P = .209 for comparison with ELF). Results from the ELF and FibroTest did not differ significantly from those of liver stiffness measurement in intention-to-diagnose analyses (AUROC for transient elastography, 0.90), but did differ in the per-protocol analysis (AUROC for transient elastography, 0.97) (P = .521 and .004 for comparison with ELF). Adding a serum marker to transient elastography analysis did not increase accuracy. For patients in primary care, ELF values below 10.5 and FibroTest values below 0.58 had negative predictive values for advanced liver fibrosis of 98% and 94%, respectively. In a prospective, direct comparison of tests, ELF and FibroTest identified advanced liver fibrosis in alcoholic patients from primary and secondary care with high diagnostic accuracy (AUROC values of 0.90 or higher using biopsy as reference). Advanced fibrosis can be ruled out in primary health care patients based on an ELF value below 10.5 or a FibroTest value below 0.58. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Demeke, Tigst; Eng, Monika
2018-05-01
Droplet digital PCR (ddPCR) has been used for absolute quantification of genetically engineered (GE) events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences ( HMG-I/Y , FatA(A), CruA and Ccf) for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A), reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the HMG-I/Y reference gene was less consistent than FatA(A) reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences) were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes.
The development of an automatic recognition system for earmark and earprint comparisons.
Junod, Stéphane; Pasquier, Julien; Champod, Christophe
2012-10-10
The value of earmarks as an efficient means of personal identification is still subject to debate. It has been argued that the field is lacking a firm systematic and structured data basis to help practitioners to form their conclusions. Typically, there is a paucity of research guiding as to the selectivity of the features used in the comparison process between an earmark and reference earprints taken from an individual. This study proposes a system for the automatic comparison of earprints and earmarks, operating without any manual extraction of key-points or manual annotations. For each donor, a model is created using multiple reference prints, hence capturing the donor within source variability. For each comparison between a mark and a model, images are automatically aligned and a proximity score, based on a normalized 2D correlation coefficient, is calculated. Appropriate use of this score allows deriving a likelihood ratio that can be explored under known state of affairs (both in cases where it is known that the mark has been left by the donor that gave the model and conversely in cases when it is established that the mark originates from a different source). To assess the system performance, a first dataset containing 1229 donors elaborated during the FearID research project was used. Based on these data, for mark-to-print comparisons, the system performed with an equal error rate (EER) of 2.3% and about 88% of marks are found in the first 3 positions of a hitlist. When performing print-to-print transactions, results show an equal error rate of 0.5%. The system was then tested using real-case data obtained from police forces. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Final report on key comparison CCQM-K100: Analysis of copper in ethanol
NASA Astrophysics Data System (ADS)
Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto
2014-01-01
The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Chisholm, Jim
2005-06-01
A further comparison of the Health and Safety Executive (HSE) standard quartz, A9950 (Sikron F600), and the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1878, standard respirable alpha-quartz, has been carried out for the four principal diffraction peaks. In the earlier comparison by Jeyaratnam and Nagar (1993, Ann Occup Hyg; 37: 167-79), the standards were both treated in ways which might change the particle size distribution and therefore the proportion of crystalline quartz. The two standards have now been compared in the most direct way possible with the minimum of sample treatment. There are no significant differences in the diffraction peak positions for the two standards. Nor do the peak area intensities differ significantly. The peak height intensities are consistently and significantly higher for Sikron F600 than for NIST SRM 1878. The particle size broadening of the diffraction peaks is evidently greater for NIST 1878, whose mass median diameter is quoted as 1.6 microm against 2.6 microm for Sikron F600. Taking the certified reference value for SRM 1878 as 95.5 +/- 1.1% crystalline quartz, the HSE standard A9950 (Sikron F600) contains 96.3 +/- 1.4% crystalline quartz based on a comparison of peak area intensities. On the same basis but using peak height intensities, the nominal crystalline quartz content of A9950 (Sikron F600) is 101.2 +/- 1.8%. Results obtained by comparison of quartz standards may not be generally applicable because of the effect of sample treatment on particle size and crystalline quartz content.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Arterial blood gas reference values for sea level and an altitude of 1,400 meters.
Crapo, R O; Jensen, R L; Hegewald, M; Tashkin, D P
1999-11-01
Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.
Comparison of lysimeter based and calculated ASCE reference evapotranspiration in a subhumid climate
NASA Astrophysics Data System (ADS)
Nolz, Reinhard; Cepuder, Peter; Eitzinger, Josef
2016-04-01
The standardized form of the well-known FAO Penman-Monteith equation, published by the Environmental and Water Resources Institute of the American Society of Civil Engineers (ASCE-EWRI), is recommended as a standard procedure for calculating reference evapotranspiration (ET ref) and subsequently plant water requirements. Applied and validated under different climatic conditions it generally achieved good results compared to other methods. However, several studies documented deviations between measured and calculated reference evapotranspiration depending on environmental and weather conditions. Therefore, it seems generally advisable to evaluate the model under local environmental conditions. In this study, reference evapotranspiration was determined at a subhumid site in northeastern Austria from 2005 to 2010 using a large weighing lysimeter (ET lys). The measured data were compared with ET ref calculations. Daily values differed slightly during a year, at which ET ref was generally overestimated at small values, whereas it was rather underestimated when ET was large, which is supported also by other studies. In our case, advection of sensible heat proved to have an impact, but it could not explain the differences exclusively. Obviously, there were also other influences, such as seasonal varying surface resistance or albedo. Generally, the ASCE-EWRI equation for daily time steps performed best at average weather conditions. The outcomes should help to correctly interpret ET ref data in the region and in similar environments and improve knowledge on the dynamics of influencing factors causing deviations.
Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa
NASA Astrophysics Data System (ADS)
Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina
2017-01-01
The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Evaluation of analytical performance based on partial order methodology.
Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin
2015-01-01
Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.
Clinical biochemistry of pregnant and nursing mares.
Harvey, John W; Pate, Melanie G; Kivipelto, Jan; Asquith, Richard L
2005-09-01
Pregnancy and lactation result in increased metabolic demands. Although homeostatic mechanisms function to keep substances in blood at relatively constant levels, some changes in the concentrations of routine clinical chemistry analytes are likely to occur. The purpose of this study was to determine what physiological changes occur in serum clinical biochemistry analytes in pregnant and nursing mares, and to determine whether the changes were substantial enough to warrant separate reference intervals for pregnant or lactating horses. Forty-two Quarter Horse, Thoroughbred, Saddlebred, Standardbred and Morgan mares were entered into the study while pregnant. They were bled once each month through birth. Studies were continued on 20 mares until their foals were weaned. Test results were tabulated by time before or after birth. Serum biochemistry values were determined by standard methods using automated analyzers. Test results were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks. If a significant difference was found (P<.05), Dunn's multiple comparison procedure was performed on all pairs. Results from pregnant and nursing mares also were compared with a reference group of 19 open, nonlactating mares. Serum triglyceride, potassium, creatinine, and total bilirubin concentrations were lower during lactation than during pregnancy. Serum calcium concentration also was slightly decreased at 2 time points during lactation. Triglyceride concentration was highest during midgestation, while bilirubin and creatinine values increased, and potassium and calcium remained constant during pregnancy. Serum urea concentration also remained constant during pregnancy but increased during lactation. Serum phosphate concentration was lowest during midgestation and highest during lactation. Total CO2 values were highest, and anion gaps were lowest, during midgestation. No significant differences were found in serum albumin, globulin, albumin:globulin ratio, total protein, or glucose values. When compared with the reference group of open mares, serum triglyceride, potassium, bilirubin, and total CO2 concentrations were lower, and anion gap was higher in horses that were nursing. Although most biochemical values remained relatively constant, significant differences were observed during pregnancy and lactation. Changes in the concentrations of triglycerides, potassium, bilirubin, total CO2, and anion gap during lactation were substantial enough to warrant separate reference intervals for lactating horses.
Leister, Iris; Mattiassich, Georg; Kindermann, Harald; Ortmaier, Reinhold; Barthofer, Jürgen; Vasvary, Imre; Katzensteiner, Klaus; Stelzhammer, Christine; Kulnik, Stefan Tino
2018-01-01
There is sparse evidence for return to sport criteria after knee injury. Functional performance deficits, particularly in fatigued muscular condition, should be verified prior to the attempt to return to high-risk pivoting sports. The purpose of this study was to generate reference values for the limb symmetry index (LSI) of healthy subjects in fatigued and non-fatigued muscular condition in a newly designed test battery. Forty-two healthy subjects [22 females, 20 males; mean (SD) age 30.4 (6.6) years] were evaluated using a test battery consisting of an isometric strength test, a series of five single-leg hop tests and an integrated fatigue protocol. Subjective physical activity was assessed with the Tegner Activity Scale (TAS). The cut-off values for healthy subjects were calculated considering the fifth percentile as the minimum reference value for the LSI and single-leg hop distance. The mean (SD) overall LSI was 98.8% (4.6). No significant gender or age specific differences in limb symmetry were observed. The comparison of the non-fatigued LSI with the overall LSI revealed no clinically relevant change due to muscular fatigue. Repeated measures ANOVA revealed a significant within effect on fatigue/non-fatigue condition ( F (1,38) = 18.000; p < 0.001, η 2 = 0.321) on absolute single-leg hop distance. Moreover, a significant between effect on the TAS-parameter ( F (1,38) = 5.928; p = 0.020, η 2 = 0.135 between: TAS ≤ 5/TAS > 5) and on gender ( F (1,38) = 23.956; p < 0.001, η 2 = 0.387) could be detected. The absolute jumping distance in the single-leg hop for distance was significantly reduced due to fatigue. No clinically relevant effect of muscular fatigue was observed on limb symmetry in our study sample. Gender and physical activity are important factors to be considered when interpreting reference values.
Noto, Nobutaka; Kato, Masataka; Abe, Yuriko; Kamiyama, Hiroshi; Karasawa, Kensuke; Ayusawa, Mamoru; Takahashi, Shori
2015-01-01
Previous studies that used carotid ultrasound have been largely conflicting in regards to whether or not patients after Kawasaki disease (KD) have a greater carotid intima-media thickness (CIMT) than controls. To test the hypothesis that there are significant differences between the values of CIMT expressed as absolute values and standard deviation scores (SDS) in children and adolescents after KD and controls, we reviewed 12 published articles regarding CIMT on KD patients and controls. The mean ± SD of absolute CIMT (mm) in the KD patients and controls obtained from each article was transformed to SDS (CIMT-SDS) using age-specific reference values established by Jourdan et al. (J: n = 247) and our own data (N: n = 175), and the results among these 12 articles were compared between the two groups and the references for comparison of racial disparities. There were no significant differences in mean absolute CIMT and mean CIMT-SDS for J between KD patients and controls (0.46 ± 0.06 mm vs. 0.44 ± 0.04 mm, p = 0.133, and 1.80 ± 0.84 vs. 1.25 ± 0.12, p = 0.159, respectively). However, there were significant differences in mean CIMT-SDS for N between KD patients and controls (0.60 ± 0.71 vs. 0.01 ± 0.65, p = 0.042). When we assessed the nine articles on Asian subjects, the difference of CIMT-SDS between the two groups was invariably significant only for N (p = 0.015). Compared with the reference values, CIMT-SDS of controls was within the normal range at a rate of 41.6 % for J and 91.6 % for N. These results indicate that age- and race-specific reference values for CIMT are mandatory for performing accurate assessment of the vascular status in healthy children and adolescents, particularly in those after KD considered at increased long-term cardiovascular risk.
Status and Opportunities for Improving the Consistency of Technical Reference Manuals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayaweera, Tina; Velonis, Aquila; Haeri, Hossein
Across the United States, energy-efficiency program administrators rely on Technical Reference Manuals (TRMs) as sources for calculations and deemed savings values for specific, well-defined efficiency measures. TRMs play an important part in energy efficiency program planning by providing a common and consistent source for calculation of ex ante and often ex post savings. They thus help reduce energy-efficiency resource acquisition costs by obviating the need for extensive measurement and verification and lower performance risk for program administrators and implementation contractors. This paper considers the benefits of establishing region-wide or national TRMs and considers the challenges of such undertaking due tomore » the difficulties in comparing energy savings across jurisdictions. We argue that greater consistency across TRMs in the approaches used to determine deemed savings values, with more transparency about assumptions, would allow better comparisons in savings estimates across jurisdictions as well as improve confidence in reported efficiency measure savings. To support this thesis, we review approaches for the calculation of savings for select measures in TRMs currently in use in 17 jurisdictions. The review reveals differences in the saving methodologies, technical assumptions, and input variables used for estimating deemed savings values. These differences are described and their implications are summarized, using four, common energy-efficiency measures as examples. Recommendations are then offered for establishing a uniform approach for determining deemed savings values.« less
Rathish, Devarajan; Senavirathna, Indika; Jayasumana, Channa; Agampodi, Suneth
2018-06-21
Assessment of acetylcholinesterase-inhibitor insecticide (AChEII) toxicity depends on the measurement of red blood cell acetylcholinesterase (RBC-AChE) activity. Its interpretation requires baseline values which is lacking in scientific literature. We aim to find the measures of central tendency and variation for RBC-AChE activity among dwellers of Anuradhapura, where the use and abuse of AChEIIs were rampant for the last few decades. A descriptive cross-sectional study with a community-based sampling for 100 healthy non-farmers (male:female = 1:1) was done using pre-determined selection criteria. Duplicate measurements of RBC-AChE activity were performed according to the modified Ellman procedure. Pearson's correlation and regression analysis were sort for RBC-AChE activity against its possible determinants. RBC-AChE activity had a mean of 449.8 (SD 74.2) mU/μM Hb with a statistical power of 0.847. It was similar to values of "healthy controls" from previous Sri Lankan toxicological studies but was low against international reference value [586.1 (SD 65.1) mU/μM Hb]. None of the possible determinants showed a significant strength of relationship with RBC-AChE activity. The baseline RBC-AChE activity among people of Anuradhapura is low in comparison with international reference values. This arises a need to find a causative mechanism.
SU-E-T-146: Reference Dosimetry for Protons and Light-Ion Beams Based on Graphite Calorimetry.
Rossomme, S; Palmans, H; Thomas, R; Lee, N; Bailey, M; Shipley, D; Al-Sulaiti, L; Cirrone, P; Romano, F; Kacperek, A; Bertrand, D; Vynckier, S
2012-06-01
The IAEA TRS-398 code of practice can be applied for the measurement of absorbed dose to water under reference conditions with an ionization chamber. For protons, the combined relative standard uncertainty on those measurements is less than 2% while for light-ion beams, it is considerably larger, i.e. 3.2%, mainly due to the higher uncertainty contributions for the water to air stopping power ration and the W air-value on the beam quality correction factors kQ,Q 0 . To decrease this uncertainty, a quantification of kQ,Q 0 is proposed using a primary standard level graphite calorimeter. This work includes numerical and experimental determinations of dose conversion factors to derive dose to water from graphite calorimetry. It also reports on the first experimental data obtained with the graphite calorimeter in proton, alpha and carbon ion beams. Firstly, the dose conversion has been calculated with by Geant4 Monte-Carlo simulations through the determination of the water to graphite stopping power ratio and the fluence correction factor. The latter factor was also derived by comparison of measured ionization curves in graphite and water. Secondly, kQ,Q 0 was obtained by comparison of the dose response of ionization chambers with that of the calorimeter. Stopping power ratios are found to vary by no more than 0.35% up to the Bragg peak, while fluence correction factors are shown to increase slightly above unity close to the Bragg peak. The comparison of the calorimeter with ionization chambers is currently under analysis. For the modulated proton beam, preliminary results on W air confirm the value recommended in TRS-398. Data in both the non-modulated proton and light-ion beams indicate higher values but further investigation of heat loss corrections is needed. The application of graphite calorimetry to proton, alpha and carbon ion beams has been demonstrated successfully. Other experimental campaigns will be held in 2012. This work is supported by the BioWin program of the Wallon Government. © 2012 American Association of Physicists in Medicine.
Invited Article: Concepts and tools for the evaluation of measurement uncertainty
NASA Astrophysics Data System (ADS)
Possolo, Antonio; Iyer, Hari K.
2017-01-01
Measurements involve comparisons of measured values with reference values traceable to measurement standards and are made to support decision-making. While the conventional definition of measurement focuses on quantitative properties (including ordinal properties), we adopt a broader view and entertain the possibility of regarding qualitative properties also as legitimate targets for measurement. A measurement result comprises the following: (i) a value that has been assigned to a property based on information derived from an experiment or computation, possibly also including information derived from other sources, and (ii) a characterization of the margin of doubt that remains about the true value of the property after taking that information into account. Measurement uncertainty is this margin of doubt, and it can be characterized by a probability distribution on the set of possible values of the property of interest. Mathematical or statistical models enable the quantification of measurement uncertainty and underlie the varied collection of methods available for uncertainty evaluation. Some of these methods have been in use for over a century (for example, as introduced by Gauss for the combination of mutually inconsistent observations or for the propagation of "errors"), while others are of fairly recent vintage (for example, Monte Carlo methods including those that involve Markov Chain Monte Carlo sampling). This contribution reviews the concepts, models, methods, and computations that are commonly used for the evaluation of measurement uncertainty, and illustrates their application in realistic examples drawn from multiple areas of science and technology, aiming to serve as a general, widely accessible reference.
A value-based medicine comparison of interventions for subfoveal neovascular macular degeneration.
Brown, Gary C; Brown, Melissa M; Brown, Heidi C; Kindermann, Sylvia; Sharma, Sanjay
2007-06-01
To perform a value-based medicine analysis of clinical trials that evaluate the interventions of laser photocoagulation, intravitreal pegaptanib therapy, and photodynamic therapy (PDT) with verteporfin for the treatment of classic subfoveal choroidal neovascularization. Reference case cost-utility analysis using value-based medicine principles, which use patient-based utility values and standardized, input variable criteria. Data from participants in the Macular Photocoagulation Study, Pegaptanib for Neovascular Age-Related Macular Degeneration Study, and the Treatment of Age-Related Macular Degeneration with Photodynamic Therapy Study. Visual data were converted to a value-based format using time tradeoff utility analysis values from patients with macular degeneration. Costs were obtained from 2005 Medicare data. Outcomes (quality-adjusted life-years [QALYs]) and costs were discounted at a 3% annual rate. Interventional QALYs gained, percent improvement in quality of life, and dollars spent per QALY gained. Laser photocoagulation confers a 4.4% (P = 0.03 versus pegaptanib therapy) improvement in quality of life for the reference case, whereas pegaptanib therapy confers a 5.9% improvement and PDT confers an 8.1% (P = 0.0002 versus pegaptanib therapy) improvement. The cost-utility associated with laser photocoagulation is $8179, that for pegaptanib therapy is $66978, and that for PDT is $31544. All sensitivity analyses remain within the conventional standards of cost-effectiveness. Photodynamic therapy confers greater patient value than intravitreal pegaptanib therapy and laser photocoagulation for the treatment of classic subfoveal choroidal neovascularization. Despite the fact that laser photocoagulation is the most cost-effective intervention, both PDT and pegaptanib therapy deliver greater value, and thus are both preferred over laser photocoagulation. Using an economic measure, photodynamic therapy is the preferred treatment among these 3 interventions.
Sorokin, Victoria; Alkhoury, Razan; Al-Rawabdeh, Sura; Houston, Ronald H; Thornton, David; Kerlin, Bryce; O'Brien, Sarah; Baker, Peter; Boesel, Carl; Uddin, Minhaj; Yin, Han; Kahwash, Samir
This study sought to determine delta granule normal ranges for children and to validate methodology for the appropriate diagnosis of delta granule deficiency (storage pool disease) by using the whole-mount technique in electron microscopy. Specimens obtained from 40 healthy volunteers (2 months of age through 21 years old, 21 females and 19 males) were tested. Results showed dense granules/platelet (DG/Plt) ranged from 1.78 to 5.25. The 5th percentile was 1.96 DG/Plt with an overall mean ± SEM 3.07 ± 0.12 DG/Plt. In comparison, a previously published lower cutoff value, 3.68 DG/Plt, was significantly higher than the mean from our volunteers (P < 0.0001). We found no variability in dense granules/platelet based on race or sex and no significant variation by age subgroup. Pending wider studies, the value of 2 DG/Plt is a more appropriate lower limit of normal. In the absence of wider studies (in healthy volunteers and patients), laboratories should consider establishing their own reference ranges.
Polyfluorinated substances in abiotic standard reference ...
The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781. Journal article published in Analytical and Bioanalytical Chemistry
Polyfluorinated substances in abiotic standard reference materials.
Reiner, Jessica L; Blaine, Andrea C; Higgins, Christopher P; Huset, Carin; Jenkins, Thomas M; Kwadijk, Christiaan J A F; Lange, Cleston C; Muir, Derek C G; Reagen, William K; Rich, Courtney; Small, Jeff M; Strynar, Mark J; Washington, John W; Yoo, Hoon; Keller, Jennifer M
2015-04-01
The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781.
Estimation of gene induction enables a relevance-based ranking of gene sets.
Bartholomé, Kilian; Kreutz, Clemens; Timmer, Jens
2009-07-01
In order to handle and interpret the vast amounts of data produced by microarray experiments, the analysis of sets of genes with a common biological functionality has been shown to be advantageous compared to single gene analyses. Some statistical methods have been proposed to analyse the differential gene expression of gene sets in microarray experiments. However, most of these methods either require threshhold values to be chosen for the analysis, or they need some reference set for the determination of significance. We present a method that estimates the number of differentially expressed genes in a gene set without requiring a threshold value for significance of genes. The method is self-contained (i.e., it does not require a reference set for comparison). In contrast to other methods which are focused on significance, our approach emphasizes the relevance of the regulation of gene sets. The presented method measures the degree of regulation of a gene set and is a useful tool to compare the induction of different gene sets and place the results of microarray experiments into the biological context. An R-package is available.
NASA Astrophysics Data System (ADS)
Kim, Chan Hyeong; Hyoun Choi, Sang; Jeong, Jong Hwi; Lee, Choonsik; Chung, Min Suk
2008-08-01
A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hnilo, J.
2006-09-19
For the fourth quarter ARM metric we will make use of new liquid water data that has become available, and called the “Microbase” value added product (referred to as OBS, within the text) at three sites: the North Slope of Alaska (NSA), Tropical West Pacific (TWP) and the Southern Great Plains (SGP) and compare these observations to model forecast data. Two time periods will be analyzed March 2000 for the SGP and October 2004 for both TWP and NSA. The Microbase data have been averaged to 35 pressure levels (e.g., from 1000hPa to 100hPa at 25hPa increments) and time averagedmore » to 3hourly data for direct comparison to our model output.« less
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Salleh, Fatmah M; Al-Mekhlafi, Abdulsalam M; Nordin, Anisah; Yasin, 'Azlin M; Al-Mekhlafi, Hesham M; Moktar, Norhayati
2011-01-01
This study was conducted to evaluate the modification of the usual Gram-chromotrope staining technique developed in-house known as Gram-chromotrope Kinyoun (GCK) in comparison with the Weber Modified Trichrome (WMT) staining technique; as the reference technique. Two hundred and ninety fecal specimens received by the Microbiology Diagnostic Laboratory of Hospital Universiti Kebangsaan Malaysia were examined for the presence of microsporidial spores. The sensitivity and specificity of GCK compared to the reference technique were 98% and 98.3%, respectively. The positive and negative predictive values were 92.5% and 99.6%, respectively. The agreement between the reference technique and the GCK staining technique was statistically significant by Kappa statistics (K = 0.941, P < 0.001). It is concluded that the GCK staining technique has high sensitivity and specificity in the detection of microsporidial spores in fecal specimens. Hence, it is recommended to be used in the diagnosis of intestinal microsporidiosis. Copyright © 2011 Elsevier Inc. All rights reserved.
Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W
2010-07-01
The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.
ERIC Educational Resources Information Center
Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.
2016-01-01
The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.
2018-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.
2016-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
PARRoT- a homology-based strategy to quantify and compare RNA-sequencing from non-model organisms.
Gan, Ruei-Chi; Chen, Ting-Wen; Wu, Timothy H; Huang, Po-Jung; Lee, Chi-Ching; Yeh, Yuan-Ming; Chiu, Cheng-Hsun; Huang, Hsien-Da; Tang, Petrus
2016-12-22
Next-generation sequencing promises the de novo genomic and transcriptomic analysis of samples of interests. However, there are only a few organisms having reference genomic sequences and even fewer having well-defined or curated annotations. For transcriptome studies focusing on organisms lacking proper reference genomes, the common strategy is de novo assembly followed by functional annotation. However, things become even more complicated when multiple transcriptomes are compared. Here, we propose a new analysis strategy and quantification methods for quantifying expression level which not only generate a virtual reference from sequencing data, but also provide comparisons between transcriptomes. First, all reads from the transcriptome datasets are pooled together for de novo assembly. The assembled contigs are searched against NCBI NR databases to find potential homolog sequences. Based on the searched result, a set of virtual transcripts are generated and served as a reference transcriptome. By using the same reference, normalized quantification values including RC (read counts), eRPKM (estimated RPKM) and eTPM (estimated TPM) can be obtained that are comparable across transcriptome datasets. In order to demonstrate the feasibility of our strategy, we implement it in the web service PARRoT. PARRoT stands for Pipeline for Analyzing RNA Reads of Transcriptomes. It analyzes gene expression profiles for two transcriptome sequencing datasets. For better understanding of the biological meaning from the comparison among transcriptomes, PARRoT further provides linkage between these virtual transcripts and their potential function through showing best hits in SwissProt, NR database, assigning GO terms. Our demo datasets showed that PARRoT can analyze two paired-end transcriptomic datasets of approximately 100 million reads within just three hours. In this study, we proposed and implemented a strategy to analyze transcriptomes from non-reference organisms which offers the opportunity to quantify and compare transcriptome profiles through a homolog based virtual transcriptome reference. By using the homolog based reference, our strategy effectively avoids the problems that may cause from inconsistencies among transcriptomes. This strategy will shed lights on the field of comparative genomics for non-model organism. We have implemented PARRoT as a web service which is freely available at http://parrot.cgu.edu.tw .
NASA Astrophysics Data System (ADS)
Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo
2009-01-01
The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Reference Values for Cardiorespiratory Fitness and Incidence of Type 2 Diabetes
Kawakami, Ryoko; Sawada, Susumu S.; Matsushita, Munehiro; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko
2014-01-01
Background In “Physical Activity Reference for Health Promotion 2013” the Japan Ministry of Health, Labour and Welfare publication gives reference values for cardiorespiratory fitness (CRF) required for good health. We examined the associations between the CRF reference values and incidence of type 2 diabetes. Methods This prospective cohort study enrolled 4633 nondiabetic Japanese men aged 20 to 39 years at baseline. CRF was measured using the cycle ergometer test, and maximal oxygen uptake was estimated. On the basis of the CRF reference value, participants were classified into 2 groups: those with values less than the reference value (under-RV) and those with values equal to or greater than reference value (over-RV). Hazard ratios (HRs) and 95% CIs for incident type 2 diabetes were estimated using a Cox proportional hazards model. Results A total of 266 participants developed type 2 diabetes during the 14 years of follow-up. As compared with the under-RV group, the over-RV group had a significantly lower multivariable-adjusted HR for type 2 diabetes (HR 0.67; 95% CI, 0.51–0.89). In receiver operating characteristic analysis, the optimal CRF cut-off value for predicting incident type 2 diabetes was 10.8 metabolic equivalents (sensitivity, 0.64; specificity, 0.64), which was close to the CRF reference value of 11.0 metabolic equivalents. Conclusions The reference CRF value appears to be reasonably valid for prevention of type 2 diabetes, especially among Japanese men younger than 40 years. Development of type 2 diabetes can be prevented by maintaining a CRF level above the reference value. PMID:24240630
NASA Astrophysics Data System (ADS)
Heinonen, Martti
2010-01-01
The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Comparison of methods for accurate end-point detection of potentiometric titrations
NASA Astrophysics Data System (ADS)
Villela, R. L. A.; Borges, P. P.; Vyskočil, L.
2015-01-01
Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.
Checking the statistical theory of liquids by ultraacoustic measurements
NASA Technical Reports Server (NTRS)
Dima, V. N.
1974-01-01
The manner of theoretically obtaining radial distribution functions 9(r) for n-hexane as a function of temperature is described. With the aid of function g(r) the coefficient of dynamic viscosity and the coefficient of volumetric viscosity for temperatures ranging from 213 K to 273 K were calculated. With the aid of the two coefficients of viscosity the coefficient of absorption of ultrasounds in n-hexane referred to the square of the frequency was determined. The same values were measured experimentally. Comparison of theory with experiments resulted in satisfactory agreement.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
Tables for simplifying calculations of activities produced by thermal neutrons
Senftle, F.E.; Champion, W.R.
1954-01-01
The method of calculation described is useful for the types of work of which examples are given. It is also useful in making rapid comparison of the activities that might be expected from several different elements. For instance, suppose it is desired to know which of the three elements, cobalt, nickel, or vanadium is, under similar conditions, activated to the greatest extent by thermal neutrons. If reference is made to a cross-section table only, the values may be misleading unless properly interpreted by a suitable comparison of half-lives and abundances. In this table all the variables have been combined and the desired information can be obtained directly from the values of A 3??, the activity produced per gram per second of irradiation, under the stated conditions. Hence, it is easily seen that, under similar circumstances of irradiation, vanadium is most easily activated even though the cross section of one of the cobalt isotopes is nearly five times that of vanadium and the cross section of one of the nickel isotopes is three times that of vanadium. ?? 1954 Societa?? Italiana di Fisica.
NASA Astrophysics Data System (ADS)
Fedchak, J. A.; Bock, Th; Jousten, K.
2014-01-01
This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Bowden, John A; Heckert, Alan; Ulmer, Candice Z; Jones, Christina M; Koelmel, Jeremy P; Abdullah, Laila; Ahonen, Linda; Alnouti, Yazen; Armando, Aaron M; Asara, John M; Bamba, Takeshi; Barr, John R; Bergquist, Jonas; Borchers, Christoph H; Brandsma, Joost; Breitkopf, Susanne B; Cajka, Tomas; Cazenave-Gassiot, Amaury; Checa, Antonio; Cinel, Michelle A; Colas, Romain A; Cremers, Serge; Dennis, Edward A; Evans, James E; Fauland, Alexander; Fiehn, Oliver; Gardner, Michael S; Garrett, Timothy J; Gotlinger, Katherine H; Han, Jun; Huang, Yingying; Neo, Aveline Huipeng; Hyötyläinen, Tuulia; Izumi, Yoshihiro; Jiang, Hongfeng; Jiang, Houli; Jiang, Jiang; Kachman, Maureen; Kiyonami, Reiko; Klavins, Kristaps; Klose, Christian; Köfeler, Harald C; Kolmert, Johan; Koal, Therese; Koster, Grielof; Kuklenyik, Zsuzsanna; Kurland, Irwin J; Leadley, Michael; Lin, Karen; Maddipati, Krishna Rao; McDougall, Danielle; Meikle, Peter J; Mellett, Natalie A; Monnin, Cian; Moseley, M Arthur; Nandakumar, Renu; Oresic, Matej; Patterson, Rainey; Peake, David; Pierce, Jason S; Post, Martin; Postle, Anthony D; Pugh, Rebecca; Qiu, Yunping; Quehenberger, Oswald; Ramrup, Parsram; Rees, Jon; Rembiesa, Barbara; Reynaud, Denis; Roth, Mary R; Sales, Susanne; Schuhmann, Kai; Schwartzman, Michal Laniado; Serhan, Charles N; Shevchenko, Andrej; Somerville, Stephen E; St John-Williams, Lisa; Surma, Michal A; Takeda, Hiroaki; Thakare, Rhishikesh; Thompson, J Will; Torta, Federico; Triebl, Alexander; Trötzmüller, Martin; Ubhayasekera, S J Kumari; Vuckovic, Dajana; Weir, Jacquelyn M; Welti, Ruth; Wenk, Markus R; Wheelock, Craig E; Yao, Libin; Yuan, Min; Zhao, Xueqing Heather; Zhou, Senlin
2017-12-01
As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.
NASA Astrophysics Data System (ADS)
Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.
2011-01-01
The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Baker, Karen; Li, Jianbo; Sabanegh, Edmund
2015-01-01
To [1] determine the impact of semen reference limits on referrals for male fertility evaluations, [2] analyze the stratification of subjects based on published "normal" thresholds, [3] analyze the odds of changing fertility categories during serial tests and thereby the potential impact of inherent variability of semen parameters on referrals, and [4] determine variable(s) predictive of change. Retrospective chart review. Academic referral center for male fertility. New encounters in a male fertility clinic over a 5-year period that straddles the publication of World Health Organization (WHO) 2010 reference values. None. Demographic and clinical variables, semen values, and fertility categories as follows: BE (below WHO 2010 criteria), BTWN (above WHO 2010 but below WHO 1999 criteria), and N (above WHO 1999 criteria). A total of 82.3% of initial semen tests were categorized as BE, and the predominance of this category was unchanged by publication of the WHO 2010 criteria. Men with initial semen analysis categorized as BTWN or N represented 16.2% and 1.5% of the referral population, respectively. Subjects initially categorized as BTWN were more likely to change fertility categories, and overwhelmingly this migration was downward. Analysis of normal individual semen parameters revealed statistically worse mean concentration and motility when at least one other parameter fell below the WHO 2010 criteria. Men with semen results above reference criteria are underrepresented, indicating that reference limits influence referral patterns for male fertility evaluations. Normal mean concentration and motility were lower in men with at least one other individual semen parameter below the 2010 criteria, suggesting global dysfunction in spermatogenesis. Published by Elsevier Inc.
The Influence of Social Comparison and Peer Group Size on Risky Decision-Making.
Wang, Dawei; Zhu, Liping; Maguire, Phil; Liu, Yixin; Pang, Kaiyuan; Li, Zhenying; Hu, Yixin
2016-01-01
This study explores the influence of different social reference points and different comparison group sizes on risky decision-making. Participants were presented with a scenario describing an exam, and presented with the opportunity of making a risky decision in the context of different information provided about the performance of their peers. We found that behavior was influenced, not only by comparison with peers, but also by the size of the comparison group. Specifically, the larger the reference group, the more polarized the behavior it prompted. In situations describing social loss, participants were led to make riskier decisions after comparing themselves against larger groups, while in situations describing social gain, they become more risk averse. These results indicate that decision making is influenced both by social comparison and the number of people making up the social reference group.
Balaban, M O; Aparicio, J; Zotarelli, M; Sims, C
2008-11-01
The average colors of mangos and apples were measured using machine vision. A method to quantify the perception of nonhomogeneous colors by sensory panelists was developed. Three colors out of several reference colors and their perceived percentage of the total sample area were selected by untrained panelists. Differences between the average colors perceived by panelists and those from the machine vision were reported as DeltaE values (color difference error). Effects of nonhomogeneity of color, and using real samples or their images in the sensory panels on DeltaE were evaluated. In general, samples with more nonuniform colors had higher DeltaE values, suggesting that panelists had more difficulty in evaluating more nonhomogeneous colors. There was no significant difference in DeltaE values between the real fruits and their screen image, therefore images can be used to evaluate color instead of the real samples.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Hullstein, Ingunn; Sagredo, Carlos; Hemmersbach, Peter
2014-01-01
Determining the origin of anabolic androgenic steroids (AAS) that also are produced endogenously in the human body is a major issue in doping control. In some cases, the presence of nandrolone and boldenone metabolites might result from endogenous production. The GC-C-IRMS technique (gas chromatography-combustion-isotope ratio mass spectrometry) enables the carbon isotopic ratio (CIR) to be measured to determine the origin of these metabolites. The aim of this study was to use GC-C-IRMS to determine the δ(13) CVPDB values of seized boldenone and nandrolone preparations to decide if the steroids themselves were depleted in (13) C, compared to what is normally seen in endogenously produced steroids. In addition, several testosterone preparations were analyzed. A total of 69 seized preparations were analyzed. The nandrolone preparations showed δ(13) CVPDB values in the range of -31.5 ‰ to -26.7 ‰. The boldenone preparations showed δ(13) CVPDB values in the range of -32.0 ‰ to -27.8 ‰, and for comparison the testosterone preparations showed δ(13) CVPDB values of -31.0 ‰ to -24.2 ‰. The results showed that the values measured in the nandrolone and boldenone preparations were in the same range as those measured in the testosterone preparations. The study also included measurements of CIR of endogenously produced steroids in a Norwegian/Danish reference population. The δ(13) CVPDB values measured for the endogenous steroids in this population were in the range of -21.7 to -26.8. In general, most of the preparations investigated in this study show (13) C-depleted delta values compared to endogenously produced steroids reflecting a northern European diet. Copyright © 2014 John Wiley & Sons, Ltd.
Aylward, L L; Hays, S M
2015-12-01
Urinary biomonitoring data for 2,4-dichlorophenoxyacetic acid (2,4-D) reflect aggregate population exposures to trace 2,4-D residues in diet and the environment. These data can be interpreted in the context of current risk assessments by comparison to a Biomonitoring Equivalent (BE), which is an estimate of the average biomarker concentration consistent with an exposure guidance value such as the US EPA Reference Dose (RfD). BE values are updated here from previous published BE values to reflect a change in the US EPA RfD. The US EPA RfD has been updated to reflect a revised point of departure (POD) based on new information from additional toxicological studies and updated assessment of applicable uncertainty factors. In addition, new biomonitoring data from both the US National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS) have been published. The updated US EPA chronic RfD of 0.21 mg/kg-d results in updated BE values of 10,500 and 7000 μg/L for adults and children, respectively. Comparison of the current population-representative data to these BE values shows that upper bound population biomarker concentrations are more than 5000-fold below BE values corresponding to the updated US EPA RfD. This biomonitoring-based risk assessment supports the conclusion that current use patterns in the US and Canada result in incidental exposures in the general population that can be considered negligible in the context of the current 2,4-D risk assessment. Copyright © 2015 Elsevier Inc. All rights reserved.
Klippenstein, Stephen J; Harding, Lawrence B; Ruscic, Branko
2017-09-07
The fidelity of combustion simulations is strongly dependent on the accuracy of the underlying thermochemical properties for the core combustion species that arise as intermediates and products in the chemical conversion of most fuels. High level theoretical evaluations are coupled with a wide-ranging implementation of the Active Thermochemical Tables (ATcT) approach to obtain well-validated high fidelity predictions for the 0 K heat of formation for a large set of core combustion species. In particular, high level ab initio electronic structure based predictions are obtained for a set of 348 C, N, O, and H containing species, which corresponds to essentially all core combustion species with 34 or fewer electrons. The theoretical analyses incorporate various high level corrections to base CCSD(T)/cc-pVnZ analyses (n = T or Q) using H 2 , CH 4 , H 2 O, and NH 3 as references. Corrections for the complete-basis-set limit, higher-order excitations, anharmonic zero-point energy, core-valence, relativistic, and diagonal Born-Oppenheimer effects are ordered in decreasing importance. Independent ATcT values are presented for a subset of 150 species. The accuracy of the theoretical predictions is explored through (i) examination of the magnitude of the various corrections, (ii) comparisons with other high level calculations, and (iii) through comparison with the ATcT values. The estimated 2σ uncertainties of the three methods devised here, ANL0, ANL0-F12, and ANL1, are in the range of ±1.0-1.5 kJ/mol for single-reference and moderately multireference species, for which the calculated higher order excitations are 5 kJ/mol or less. In addition to providing valuable references for combustion simulations, the subsequent inclusion of the current theoretical results into the ATcT thermochemical network is expected to significantly improve the thermochemical knowledge base for less-well studied species.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klippenstein, Stephen J.; Harding, Lawrence B.; Ruscic, Branko
Here, the fidelity of combustion simulations is strongly dependent on the accuracy of the underlying thermochemical properties for the core combustion species that arise as intermediates and products in the chemical conversion of most fuels. High level theoretical evaluations are coupled with a wide-ranging implementation of the Active Thermochemical Tables (ATcT) approach to obtain well-validated high fidelity predictions for the 0 K heat of formation for a large set of core combustion species. In particular, high level ab initio electronic structure based predictions are obtained for a set of 348 C, N, O, and H containing species, which corresponds tomore » essentially all core combustion species with 34 or fewer electrons. The theoretical analyses incorporate various high level corrections to base CCSD(T)/cc-pVnZ analyses (n = T or Q) using H 2, CH 4, H 2O, and NH 3 as references. Corrections for the complete-basis-set limit, higher-order excitations, anharmonic zeropoint energy, core–valence, relativistic, and diagonal Born–Oppenheimer effects are ordered in decreasing importance. Independent ATcT values are presented for a subset of 150 species. The accuracy of the theoretical predictions is explored through (i) examination of the magnitude of the various corrections, (ii) comparisons with other high level calculations, and (iii) through comparison with the ATcT values. The estimated 2σ uncertainties of the three methods devised here, ANL0, ANL0-F12, and ANL1, are in the range of ±1.0–1.5 kJ/mol for single-reference and moderately multireference species, for which the calculated higher order excitations are 5 kJ/mol or less. In addition to providing valuable references for combustion simulations, the subsequent inclusion of the current theoretical results into the ATcT thermochemical network is expected to significantly improve the thermochemical knowledge base for less-well studied species.« less
A candidate reference method using ICP-MS for sweat chloride quantification.
Collie, Jake T; Massie, R John; Jones, Oliver A H; Morrison, Paul D; Greaves, Ronda F
2016-04-01
The aim of the study was to develop a method for sweat chloride (Cl) quantification using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to present to the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as a candidate reference method for the diagnosis of cystic fibrosis (CF). Calibration standards were prepared from sodium chloride (NaCl) to cover the expected range of sweat Cl values. Germanium (Ge) and scandium (Sc) were selected as on-line (instrument based) internal standards (IS) and gallium (Ga) as the off-line (sample based) IS. The method was validated through linearity, accuracy and imprecision studies as well as enrolment into the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) for sweat electrolyte testing. Two variations of the ICP-MS method were developed, an on-line and off-line IS, and compared. Linearity was determined up to 225 mmol/L with a limit of quantitation of 7.4 mmol/L. The off-line IS demonstrated increased accuracy through the RCPAQAP performance assessment (CV of 1.9%, bias of 1.5 mmol/L) in comparison to the on-line IS (CV of 8.0%, bias of 3.8 mmol/L). Paired t-tests confirmed no significant differences between sample means of the two IS methods (p=0.53) or from each method against the RCPAQAP target values (p=0.08 and p=0.29). Both on and off-line IS methods generated highly reproducible results and excellent linear comparison to the RCPAQAP target results. ICP-MS is a highly accurate method with a low limit of quantitation for sweat Cl analysis and should be recognised as a candidate reference method for the monitoring and diagnosis of CF. Laboratories that currently practice sweat Cl analysis using ICP-MS should include an off-line IS to help negate any pre-analytical errors.
Klippenstein, Stephen J.; Harding, Lawrence B.; Ruscic, Branko
2017-07-31
Here, the fidelity of combustion simulations is strongly dependent on the accuracy of the underlying thermochemical properties for the core combustion species that arise as intermediates and products in the chemical conversion of most fuels. High level theoretical evaluations are coupled with a wide-ranging implementation of the Active Thermochemical Tables (ATcT) approach to obtain well-validated high fidelity predictions for the 0 K heat of formation for a large set of core combustion species. In particular, high level ab initio electronic structure based predictions are obtained for a set of 348 C, N, O, and H containing species, which corresponds tomore » essentially all core combustion species with 34 or fewer electrons. The theoretical analyses incorporate various high level corrections to base CCSD(T)/cc-pVnZ analyses (n = T or Q) using H 2, CH 4, H 2O, and NH 3 as references. Corrections for the complete-basis-set limit, higher-order excitations, anharmonic zeropoint energy, core–valence, relativistic, and diagonal Born–Oppenheimer effects are ordered in decreasing importance. Independent ATcT values are presented for a subset of 150 species. The accuracy of the theoretical predictions is explored through (i) examination of the magnitude of the various corrections, (ii) comparisons with other high level calculations, and (iii) through comparison with the ATcT values. The estimated 2σ uncertainties of the three methods devised here, ANL0, ANL0-F12, and ANL1, are in the range of ±1.0–1.5 kJ/mol for single-reference and moderately multireference species, for which the calculated higher order excitations are 5 kJ/mol or less. In addition to providing valuable references for combustion simulations, the subsequent inclusion of the current theoretical results into the ATcT thermochemical network is expected to significantly improve the thermochemical knowledge base for less-well studied species.« less
NASA Astrophysics Data System (ADS)
Sharma, Vashundhra; Jaiswal, Pradeep K.; Saran, Mukesh; Yadav, Dharmendra Kumar; Saloni; Mathur, Manas; Swami, Ajit K.; Misra, Sanjeev; Kim, Mi-hyun; Chaudhary, Sandeep
2018-03-01
The discovery of C-3 tethered 2-oxo-benzo[1,4]oxazines as potent antioxidants is disclosed. All the analogues 20a-20ab have been synthesized via “on water” ultrasound-assisted in excellent yields (upto 98%). All the compounds have been evaluated for their in vitro antioxidant activities using DPPH free radical scavenging assay as well as FRAP assay. The result showed promising antioxidant activities having IC50 values in the range of 4.74 ± 0.08 to 92.20 ± 1.54 μg/mL taking ascorbic acid (IC50 = 4.57 μg/mL) as standard reference. In this study, compounds 20b and 20t, the most active compound of the series, showed IC50 values of 6.89 ± 0.07μg/mL and 4.74 ± 0.08 μg/mL, respectively in comparison with ascorbic acid. In addition, the detailed SAR study shows that electron-withdrawing group increases antioxidant activity and vice versa. Furthermore, in the FRAP assay, eight compounds (20c, 20j, 20m, 20n, 20r, 20u, 20z and 20aa) were found more potent than standard reference BHT (C0.5FRAP = 546.0 ± 13.6 μM). The preliminary cytotoxic study reveals the non-toxic nature of active compounds 20b and 20t in non-cancerous 3T3 fibroblast cell lines in MTT assay up to 250 μg/mL concentration. The results were validated via carrying out insilico molecular docking studies of promising compounds 20a, 20b and 20t in comparison with standard reference. To the best of our knowledge, this is the first detailed study of C-3 tethered 2-oxo-benzo[1,4]oxazines as potential antioxidant agents.
Dynamic Heights in the Great Lakes at Different Epochs
NASA Astrophysics Data System (ADS)
Roman, D. R.
2016-12-01
Vertical control in the Great Lakes region is currently defined by the International Great Lakes Datum of 1985 (IGLD 85) in the form of dynamic heights. Starting in 2025, dynamic heights will be defined through GNSS-derived geometric coordinates and a geopotential model. This paper explores the behavior of an existing geopotential model at different epochs when the Great Lakes were at significantly different (meter-level) geopotential surfaces. Water surfaces were examined in 2015 and 2010 at six sites on Lakes Superior and Lake Erie (three on each Lake). These sites have collocated a Continuously Operating Reference Station (CORS) and a Water Level Sensor (WLS). The offset between the antenna phase center for the CORS and the WLS datum are known at each site. The WLS then measures the distance from its datum to the Lake surface via an open well. Thus it is possible to determine the height above an ellipsoid datum at these sites as long as both the CORS and WLS are operational. The geometric coordinates are then used to estimate the geopotential value from the xGEOID16B model. This accomplished in two steps. To provide an improved reference model, EGM2008 was spectrally enhanced using observations from the GOCE satellite gravity mission and aerogravity from the Gravity for the Redefinition of the American Vertical Datum (GRAV-D) Project. This enhanced model, xGEOID16B_Ref, is still only a five arcminute resolution model (d/o 2160), but resolves dynamic heights at about 2 cm on Lake Superior for December 2015. The reference model was primarily developed to determine a one arcminute geoid height grid, xGEOID16B, available on the NGS website. This geoid height model was used to iteratively develop improved geopotential value for each of the site locations, which then improved comparisons to the cm-level. Comparisons were then made at the 2010 epoch for these same locations to determine if the performance of the geopotential model was consistent.
Social comparison, personal relative deprivation, and materialism.
Kim, Hyunji; Callan, Mitchell J; Gheorghiu, Ana I; Matthews, William J
2017-06-01
Across five studies, we found consistent evidence for the idea that personal relative deprivation (PRD), which refers to resentment stemming from the belief that one is deprived of deserved outcomes compared to others, uniquely contributes to materialism. In Study 1, self-reports of PRD positively predicted materialistic values over and above socioeconomic status, personal power, self-esteem, and emotional uncertainty. The experience of PRD starts with social comparison, and Studies 2 and 3 found that PRD mediated the positive relation between a tendency to make social comparisons of abilities and materialism. In Study 4, participants who learned that they had less (vs. similar) discretionary income than people like them reported a stronger desire for more money relative to donating more to charity. In Study 5, during a windfall-spending task, participants higher in PRD spent more on things they wanted relative to other spending categories (e.g., paying off debts). © 2016 The Authors. British Journal of Social Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
Intermolecular symmetry-adapted perturbation theory study of large organic complexes.
Heßelmann, Andreas; Korona, Tatiana
2014-09-07
Binding energies for the complexes of the S12L database by Grimme [Chem. Eur. J. 18, 9955 (2012)] were calculated using intermolecular symmetry-adapted perturbation theory combined with a density-functional theory description of the interacting molecules. The individual interaction energy decompositions revealed no particular change in the stabilisation pattern as compared to smaller dimer systems at equilibrium structures. This demonstrates that, to some extent, the qualitative description of the interaction of small dimer systems may be extrapolated to larger systems, a method that is widely used in force-fields in which the total interaction energy is decomposed into atom-atom contributions. A comparison of the binding energies with accurate experimental reference values from Grimme, the latter including thermodynamic corrections from semiempirical calculations, has shown a fairly good agreement to within the error range of the reference binding energies.
NASA Technical Reports Server (NTRS)
Keating, G. M. (Editor)
1989-01-01
A set of preliminary reference atmosphere models of significant trace species which play important roles in controlling the chemistry, radiation budget, and circulation patterns of the atmosphere were produced. These models of trace species distributions are considered to be reference models rather than standard models; thus, it was not crucial that they be correct in an absolute sense. These reference models can serve as a means of comparison between individual observations, as a first guess in inversion algorithms, and as an approximate representation of observations for comparison to theoretical calculations.
KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas
NASA Astrophysics Data System (ADS)
Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.
2010-01-01
Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Interleukin-6 and tumor necrosis factor-alpha values in elk neonates
Barber-Meyer, S. M.; Johnson, C.R.; Murtaugh, M.P.; Mech, L.D.; White, P.J.
2007-01-01
Serological indicators of general condition would be helpful for monitoring or assessing ungulate wildlife. Toward that end, we report the 1st reference values for 2 cytokines, interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-??), in neonatal elk (Cervus elaphus). We obtained blood samples from 140 calves ??? 6 days old in Yellowstone National Park during summer 2003-2005. TL-6 values ranged from 0 to 1.21 pg/ml with a median of 0.03 pg/ml. TNF-?? values ranged from 0 to 225.43 pg/ml with a median of 1.85 pg/ml. IL-6 and TNF-?? concentrations were not significant predictors of elk calf survival through 21 days. Development of ungulate-based IL-6 and TNF-?? assays that provide greater sensitivity than cross-reacting human-based assays could be helpful in monitoring ungulate condition and health status comparisons among herds. Such information could provide indirect assessments of range quality or environmental influences among herds.
Wang, Qiang; Jia, Qingzhu; Yan, Lihong; Xia, Shuqian; Ma, Peisheng
2014-08-01
The aquatic toxicity value of hazardous contaminants plays an important role in the risk assessments of aquatic ecosystems. The following study presents a stable and accurate structure-toxicity relationship model based on the norm indexes for the prediction of toxicity value (log(LC50)) for 190 diverse narcotic pollutants (96 h LC50 data for Poecilia reticulata). Research indicates that this new model is very efficient and provides satisfactory results. The suggested prediction model is evidenced by R(2) (square correlation coefficient) and ARD (average relative difference) values of 0.9376 and 10.45%, respectively, for the training set, and 0.9264 and 13.90% for the testing set. Comparison results with reference models demonstrate that this new method, based on the norm indexes proposed in this work, results in significant improvements, both in accuracy and stability for predicting aquatic toxicity values of narcotic pollutants. Copyright © 2014 Elsevier Ltd. All rights reserved.
2013-01-01
Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145
Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao
2013-03-12
The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.
NASA Astrophysics Data System (ADS)
Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Zivkovic, V.
2015-01-01
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Directorate of Measures and Precious Metals (DMDM), Beograd, Serbia, was carried out from January to March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMA (ZA), were transported by freight to DMDM. At DMDM, the reference standard for DC voltage is a Josephson Voltage Standard. The output electromotive force of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DMDM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DMDM, at the level of 1.018 V and 10 V, at DMDM, UDMDM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 13 February 2014. UDMDM - UBIPM = 0.094 µV uc = 0.072 µV, at 1 V UDMDM - UBIPM = 0.39 µV uc = 0.12 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DMDM, based on KJ-90, and the uncertainty related to the comparison. The results at the 10 V level are not covered by the uncertainties with a coverage factor of 2. After the distribution of the Draft A, the DMDM discovered that the pressure gauge was defective. Some considerations on the correction to apply on the comparison result and the corresponding uncertainties are presented in the report. Nevertheless, the above results fully cover the CMCs of DMDM which are significantly larger. No corrections for temperature and pressure are applied in calibrations for customers' secondary standards. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Astrometry of the h and χ Persei clusters based on the processing of digitized photographic plates
NASA Astrophysics Data System (ADS)
Muminov, Muydin; Yuldoshev, Qudrat; Ehgamberdiev, Shukhrat; Kahharov, Bakhtiyor; Relke, Helena; Protsyuk, Yury; Pakuliak, Ludmila; Andruk, Vitaly
2017-01-01
The work was carried out to ascertain the possibility of using the scanner Epson Expression 10000XL of Astronomical Institute Academy of Sciences of Uzbekistan for any astrometric and photometric works. Photographic plates were obtained with the normal astrograph of Astronomical Institute (D/F = 330mm/3467mm, M = 59.56 "/mm). The digitizing of photographic plates with linear dimensions 16 x 16 cm was made with a spatial resolution of 1200 dpi (1px = 1.25"). For this study the images of the first (1935.0) and second (1976.9 ) epochs were used in the sky area of 4 sq. degrees with the χ and h Persei open clusters. Positions and B-magnitudes of the stars were obtained in the system of the TYCHO2 reference catalogue. The errors of differences in the positions and proper motions for the 655 reference stars used for the astrometric reduction are σ_{αδ} = ± 0.0.074" and σ_{μαδ} = ± 0.0018"/year respectively. The internal photometric errors σ_m are ±0.065^m. The comparison of the determined B-magnitudes with the B-magnitudes of the TYCHO2 gave the error values of σ_B = ±0.208^m. The comparison of 8123 common stars down to B ≤ 17.5^m with UCAC4 gave the error values of σ_{αδ} = ±0.28", σ_{μαδ} = ±0.0075"/year and σ_m = ±0.139^m for positions, proper motions and stellar magnitudes respectively.
Luo, Mingxu; Song, Hongmei; Liu, Gang; Lin, Yikai; Luo, Lintao; Zhou, Xin; Chen, Bo
2017-01-01
The diagnostic values of diffusion weighted imaging (DWI) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for N-staging of gastric cancer (GC) were identified and compared. After a systematic search to identify relevant articles, meta-analysis was used to summarize the sensitivities, specificities, and areas under curves (AUCs) for DWI and PET/CT. To better understand the diagnostic utility of DWI and PET/CT for N-staging, the performance of multi-detector computed tomography (MDCT) was used as a reference. Fifteen studies were analyzed. The pooled sensitivity, specificity, and AUC with 95% confidence intervals of DWI were 0.79 (0.73–0.85), 0.69 (0.61–0.77), and 0.81 (0.77–0.84), respectively. For PET/CT, the corresponding values were 0.52 (0.39–0.64), 0.88 (0.61–0.97), and 0.66 (0.62–0.70), respectively. Comparison of the two techniques revealed DWI had higher sensitivity and AUC, but no difference in specificity. DWI exhibited higher sensitivity but lower specificity than MDCT, and 18F-FDG PET/CT had lower sensitivity and equivalent specificity. Overall, DWI performed better than 18F-FDG PET/CT for preoperative N-staging in GC. When the efficacy of MDCT was taken as a reference, DWI represented a complementary imaging technique, while 18F-FDG PET/CT had limited utility for preoperative N-staging. PMID:29137440
NASA Technical Reports Server (NTRS)
Strapp, John W.; Lilie, Lyle E.; Ratvasky, Thomas P.; Davison, Craig R.; Dumont, Christopher J.
2016-01-01
A new Isokinetic Total Water Content Evaporator (IKP2) was downsized from a prototype instrument, specifically to make airborne measurements of hydrometeor total water content (TWC) in deep tropical convective clouds to assess the new ice crystal Appendix D icing envelope. The probe underwent numerous laboratory and wind tunnel investigations to ensure reliable operation under the difficult high altitude/speed/TWC conditions under which other TWC instruments have been known to either fail, or have unknown performance characteristics. The article tracks the testing and modifications of the IKP2 probe to ensure its readiness for three flight campaigns in 2014 and 2015. Comparisons are made between the IKP2 and the NASA Icing Research Tunnel reference values in liquid conditions, and to an exploratory technique estimating ice water content from a bulk ice capture cylinder method in glaciated conditions. These comparisons suggest that the initial target of 20 percent accuracy in TWC has been achieved and likely exceeded for tested TWC values in excess of about 0.5 gm (exp -3). Uncertainties in the ice water content reference method have been identified. Complications are introduced in the necessary subtraction of an independently measured background water vapour concentration, errors of which are small at the colder flight temperatures, but increase rapidly with increasing temperature, and ultimately limit the practical use of the instrument in a tropical convective atmosphere to conditions colder than about 0 degrees C. A companion article in this conference traces the accuracy of the components of the IKP2 to derive estimated system accuracy.
NASA Technical Reports Server (NTRS)
Strapp, J. Walter; Lilie, Lyle E.; Ratvasky, Thomas P.; Davison, Craig; Dumont, Chris
2016-01-01
A new Isokinetic Total Water Content Evaporator (IKP2) was downsized from a prototype instrument, specifically to make airborne measurements of hydrometeor total water content (TWC) in deep tropical convective clouds to assess the new ice crystal Appendix D icing envelope. The probe underwent numerous laboratory and wind tunnel investigations to ensure reliable operation under the difficult high altitude/speed/TWC conditions under which other TWC instruments have been known to either fail, or have unknown performance characteristics. The article tracks the testing and modifications of the IKP2 probe to ensure its readiness for three flight campaigns in 2014 and 2015. Comparisons are made between the IKP2 and the NASA Icing Research Tunnel reference values in liquid conditions, and to an exploratory technique estimating ice water content from a bulk ice capture cylinder method in glaciated conditions. These comparisons suggest that the initial target of 20% accuracy in TWC has been achieved and likely exceeded for tested TWC values in excess of about 0.5/cu gm. Uncertainties in the ice water content reference method have been identified. Complications are introduced in the necessary subtraction of an independently measured background water vapor concentration, errors of which are small at the colder flight temperatures, but increase rapidly with increasing temperature, and ultimately limit the practical use of the instrument in a tropical convective atmosphere to conditions colder than about 0 C. A companion article in this conference traces the accuracy of the components of the IKP2 to derive estimated system accuracy.
Nasal potential difference outcomes support diagnostic decisions in cystic fibrosis.
Tridello, Gloria; Menin, Laura; Pintani, Emily; Bergamini, Gabriella; Assael, Baroukh Maurice; Melotti, Paola
2016-09-01
When cystic fibrosis (CF) is suspected Nasal Potential Difference (NPD) measurements are proposed to support controversial diagnosis: we investigated appropriate outcomes at the CF Centre of Verona. NPD were measured in 196 subjects: 50 non-CF, 65 classical CF (the reference group) and 81 with uncertain CF (case group). Discriminating power was determined by comparison between several outcomes from the CF reference group versus non-CF: basal, amiloride, 0Cl, isoproterenol, ATP, Delta-amiloride, Delta-0Cl, Delta-isoproterenol, Delta-ATP, Delta-isoproterenol+Delta-0Cl, Wilschanski Index (WI) and Sermet score (SS). The most appropriate cut-off values for variables with the best discriminating power were then applied to the case group. Descriptive statistics, logistic regression models and ROC curve analysis were applied. WI and SS were the most powerful in discriminating CF from non-CF subjects. In the reference group sensitivity of the 0.82 WI cut-off was 98%, specificity 96%; both sensitivity and specificity of the -0.44 SS cut-off value were 100%. For the case group, WI and SS were, respectively, consistent with CF diagnosis in 94% and 92% of the cases. Formulae have the highest discriminating power and can support the diagnosis in uncertain cases; they should be utilized for standardized interpretation of NPD for diagnosis and possibly for clinical research. Copyright © 2016. Published by Elsevier B.V.
Reference charts for fetal biometric parameters in twin pregnancies according to chorionicity.
Araujo Júnior, Edward; Ruano, Rodrigo; Javadian, Pouya; Martins, Wellington P; Elito, Julio; Pires, Claudio Rodrigues; Zanforlin Filho, Sebastião Marques
2014-04-01
The objective of this article is to determine reference values for fetal biometric parameters in twin pregnancies and to compare these values between monochorionic and dichorionic pregnancies. A retrospective cross-sectional study was conducted among 157 monochorionic and 176 dichorionic twin pregnancies between 14 and 38 weeks of gestation. Biometric measurements included the biparietal diameter (BPD), abdominal circumference (AC), femurs length (FL) and estimated fetal weight (EFW). To evaluate the correlation between biometric parameters and gestational age, polynomial regression models were created, with adjustments using the coefficient of determination (R(2) ). Comparison between monochorionic and dichorionic pregnancies was performed using analysis of covariance. The mean BPD, AC, FL and EFW for the dichorionic pregnancies were 56.16 mm, 191.1 mm, 41.08 mm and 816.1 g, respectively. The mean BPD, AC, FL and EFW for the monochorionic pregnancies were 57.14 mm, 184.2 mm, 39.29 mm and 723.4 g, respectively. There was a statistical difference between mono and dichorionic pregnancies for all the biometric parameters (BPD p = 0.012; AC p = 0.047; FL p = 0.007; EFW p = 0.011). Reference curves of biometric parameters in twin pregnancies were determined. Biometric parameters were statistically different between monochorionic and dichorionic pregnancies. © 2014 John Wiley & Sons, Ltd.
Work ability of workers in western China: reference data.
Lin, Sihao; Wang, Zhiming; Wang, Mianzhen
2006-03-01
The Work Ability Index (WAI) is a validated and widely used research tool. Reference data for Chinese workers by age, gender and work content are poorly documented or lacking. To provide reference data for work ability among workers in western China. A random sample of 10 218 workers (including manual, professional, clerical and semi-skilled workers) in western China, aged 16-69 years, was taken from several studies and the WAI questionnaire was administered. All the WAI scores were distributed continuously and nearly normally. The WAI for female workers was significantly higher than for males (P < 0.01) and the 'poor' WAI category only accounted for 3% of females, against 6% of males. WAI scores declined with age and changed variably among workers according to work content and age. Mean WAI scores of manual workers declined rapidly beyond the age of 35 years, and beyond age 45 years for professional and clerical workers. WAI scores were distributed differently according to work content and age group (P < 0.01). WAI categories differed by work content and age group both for male and female workers. WAI is validated in Chinese occupational practices. Some reference data are different from Finnish data. This study provides gender, age and work-content-specific WAI reference values that will help enable comparison and intervention evaluation in further studies.
The Influence of Social Comparison and Peer Group Size on Risky Decision-Making
Wang, Dawei; Zhu, Liping; Maguire, Phil; Liu, Yixin; Pang, Kaiyuan; Li, Zhenying; Hu, Yixin
2016-01-01
This study explores the influence of different social reference points and different comparison group sizes on risky decision-making. Participants were presented with a scenario describing an exam, and presented with the opportunity of making a risky decision in the context of different information provided about the performance of their peers. We found that behavior was influenced, not only by comparison with peers, but also by the size of the comparison group. Specifically, the larger the reference group, the more polarized the behavior it prompted. In situations describing social loss, participants were led to make riskier decisions after comparing themselves against larger groups, while in situations describing social gain, they become more risk averse. These results indicate that decision making is influenced both by social comparison and the number of people making up the social reference group. PMID:27582723
Comparative Study of Impedance Eduction Methods. Part 1; DLR Tests and Methodology
NASA Technical Reports Server (NTRS)
Busse-Gerstengarbe, Stefan; Bake, Friedrich; Enghardt, Lars; Jones, Michael G.
2013-01-01
The absorption efficiency of acoustic liners used in aircraft engines is characterized by the acoustic impedance. World wide, many grazing ow test rigs and eduction methods are available that provide values for that impedance. However, a direct comparison and assessment of the data of the di erent rigs and methods is often not possible because test objects and test conditions are quite di erent. Only a few papers provide a direct comparison. Therefore, this paper together with a companion paper, present data measured with a reference test object under similar conditions in the DLR and NASA grazing ow test rigs. Additionally, by applying the in-house methods Liner Impedance Non-Uniform ow Solving algorithm (LINUS, DLR) and Convected Helmhholtz Equation approach (CHE, NASA) on the data sets, similarities and differences due to underlying theory are identi ed and discussed.
NASA Astrophysics Data System (ADS)
Widlowski, J.-L.; Pinty, B.; Lopatka, M.; Atzberger, C.; Buzica, D.; Chelle, M.; Disney, M.; Gastellu-Etchegorry, J.-P.; Gerboles, M.; Gobron, N.; Grau, E.; Huang, H.; Kallel, A.; Kobayashi, H.; Lewis, P. E.; Qin, W.; Schlerf, M.; Stuckens, J.; Xie, D.
2013-07-01
The radiation transfer model intercomparison (RAMI) activity aims at assessing the reliability of physics-based radiative transfer (RT) models under controlled experimental conditions. RAMI focuses on computer simulation models that mimic the interactions of radiation with plant canopies. These models are increasingly used in the development of satellite retrieval algorithms for terrestrial essential climate variables (ECVs). Rather than applying ad hoc performance metrics, RAMI-IV makes use of existing ISO standards to enhance the rigor of its protocols evaluating the quality of RT models. ISO-13528 was developed "to determine the performance of individual laboratories for specific tests or measurements." More specifically, it aims to guarantee that measurement results fall within specified tolerance criteria from a known reference. Of particular interest to RAMI is that ISO-13528 provides guidelines for comparisons where the true value of the target quantity is unknown. In those cases, "truth" must be replaced by a reliable "conventional reference value" to enable absolute performance tests. This contribution will show, for the first time, how the ISO-13528 standard developed by the chemical and physical measurement communities can be applied to proficiency testing of computer simulation models. Step by step, the pre-screening of data, the identification of reference solutions, and the choice of proficiency statistics will be discussed and illustrated with simulation results from the RAMI-IV "abstract canopy" scenarios. Detailed performance statistics of the participating RT models will be provided and the role of the accuracy of the reference solutions as well as the choice of the tolerance criteria will be highlighted.
Nofoam System Technology for Aircraft Hangar Fire Suppression Foam System
2011-07-01
use of a firefighting agent that meets Military Specification MIL - F - 24385 [Reference 2]. Significant amounts of AFFF wastewater is generated...rates, Table 3, were the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference...flow rates, Table 3, was the established baseline for comparison. Table 3 theoretical flow rates were derived from Military Specification MIL - F - 24385 [Reference
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.
Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela
2013-10-01
Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.
The genotypic diversity and lipase production of some thermophilic bacilli from different genera
Koc, Melih; Cokmus, Cumhur; Cihan, Arzu Coleri
2015-01-01
Abstract Thermophilic 32 isolates and 20 reference bacilli were subjected to Rep-PCR and ITS-PCR fingerprinting for determination of their genotypic diversity, before screening lipase activities. By these methods, all the isolates and references could easily be differentiated up to subspecies level from each other. In screening assay, 11 isolates and 7 references were found to be lipase producing. Their extracellular lipase activities were measured quantitatively by incubating in both tributyrin and olive oil broths at 60 °C and pH 7.0. During the 24, 48 and 72-h period of incubation, the changes in the lipase activities, culture absorbance, wet weight of biomass and pH were all measured. The activity was determined by using pNPB in 50 mM phosphate buffer at pH 7.0 at 60 °C. The lipase production of the isolates in olive oil broths varied between 0.008 and 0.052, whereas these values were found to be 0.002-0.019 (U/mL) in the case of tyributyrin. For comparison, an index was established by dividing the lipase activities to cell biomass (U/mg). The maximum thermostable lipase production was achieved by the isolates F84a, F84b, and G. thermodenitrificans DSM 465T (0.009, 0.008 and 0.008 U/mg) within olive oil broth, whereas G. stearothermophilus A113 displayed the highest lipase activity than its type strain in tyributyrin. Therefore, as some of these isolates displayed higher activities in comparison to references, new lipase producing bacilli were determined by presenting their genotypic diversity with DNA fingerprinting techniques. PMID:26691464
Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers
NASA Astrophysics Data System (ADS)
del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.
2015-01-01
An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Dobrowolska, D.; Kosterov, A.
2016-01-01
This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)
NASA Astrophysics Data System (ADS)
Šetina, Janez; Vičar, Martin; Pražák, Dominik
2015-01-01
The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.
2011-01-01
A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Interferometric measurement of the 1S/sub 1/2/-2S/sub 1/2/ transition frequency in atomic hydrogen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barr, J.R.M.; Girkin, J.M.; Tolchard, J.M.
The 1S/sub 1/2/-2S/sub 1/2/ transition frequency in atomic hydrogen has been interferometrically measured by comparison with a reference line in /sup 130/Te/sub 2/ by Doppler-free two-photon laser spectroscopy. The measured 1S/sub 1/2/-2S/sub 1/2/ transition frequency of 2 466 061 397(25) MHz is in good agreement with the theoretical predictions of Erickson modified to take account of recent measurements of the Rydberg constant. This measurement can be used to deduce a value for the ground-state Lamb shift and gives the result of 8182(25) MHz which compares with a value of 8173.248(81) MHz predicted by Erickson.
NASA Astrophysics Data System (ADS)
Protsyuk, Yu. I.; Kovylianska, O. E.; Protsyuk, S. V.; Yizhakevych, O. M.; Andruk, V. M.; Golovnia, V. V.; Yuldoshev, Q. K.
2017-02-01
The bulk of planet observations was obtained in RI MAO and MAO NASU from 1961 to 1994. Plates from AI UAS were also used. Each plate of NAO was scanned 6 times, in other observatories - only once. All images are processed, most of them are identified and the equatorial coordinates of all objects were obtained. Positional accuracy of the reference stars has value of 0.04"-0.30". Standard deviation of the planets' position is in the range 0.10-0.12 pixels, that corresponds, depending on the scale, from 0".08 to 0".26. The comparison of the new topocentric positions of the planets with JPL/HORIZONS ephemeris was made. Calculation of (O-C) values and their standard deviation is obtained.
A new NIST primary standardization of 18F.
Fitzgerald, R; Zimmerman, B E; Bergeron, D E; Cessna, J C; Pibida, L; Moreira, D S
2014-02-01
A new primary standardization of (18)F by NIST is reported. The standard is based on live-timed beta-gamma anticoincidence counting with confirmatory measurements by three other methods: (i) liquid scintillation (LS) counting using CIEMAT/NIST (3)H efficiency tracing; (ii) triple-to-double coincidence ratio (TDCR) counting; and (iii) NaI integral counting and HPGe γ-ray spectrometry. The results are reported as calibration factors for NIST-maintained ionization chambers (including some "dose calibrators"). The LS-based methods reveal evidence for cocktail instability for one LS cocktail. Using an ionization chamber to link this work with previous NIST results, the new value differs from the previous reports by about 4%, but appears to be in good agreement with the key comparison reference value (KCRV) of 2005. © 2013 Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza
2013-01-01
The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance regression was used to establish the key comparison reference function (KCRF) relating the assigned values to the repeatability measurements. Parametric bootstrap Monte Carlo was used to estimate 95% level-of-confidence coverage intervals for the degrees of equivalence of materials, d +/- U95(d), and of the participating NMIs, D +/- U95(D). Because of the wide range of creatinine mass fraction in the materials, these degrees of equivalence are expressed in percent relative form: %d +/- U95(%d) and %D +/- U95(%D). On the basis of leave-one-out cross-validation, the assigned values for 16 of the 17 materials were deemed equivalent at the 95% level of confidence. These materials were used to define the KCRF. The excluded material was identified as having a marginally underestimated assigned uncertainty, giving it large and potentially anomalous influence on the KCRF. However, this material's %d of 1.4 +/- 1.5 indicates that it is equivalent with the other materials at the 95% level of confidence. The median |%d| for all 17 of the materials is 0.3 with a median U95(%d) of 1.9. All of these higher-order CRMs for creatinine in human serum are equivalent within their assigned uncertainties. The median |%D| for the participating NMIs is 0.3 with a median U95(%D) of 2.1. These results demonstrate that all participating NMIs have the ability to correctly value-assign CRMs and proficiency test materials for creatinine in human serum and similar measurands. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Time evolution of an SLR reference frame
NASA Astrophysics Data System (ADS)
Angermann, D.; Gerstl, M.; Kelm, R.; Müller, H.; Seemüller, W.; Vei, M.
2002-07-01
On the basis of LAGEOS-1 and LAGEOS-2 data we computed a 10-years (1990-2000) solution for SLR station positions and velocities. The paper describes the data processing with the DGFI software package DOGS. We present results for station coordinates and their time variation for 41 stations of the global SLR network, and discuss the stability and time evolution of the SLR reference frame established in the same way. We applied different methods to assess the quality and consistency of the SLR results. The results presented in this paper include: (1) a time series of weekly estimated station coordinates; (2) a comparison of a 10-year LAGEOS-1 and LAGEOS-2 solution; (3) a comparison of 2.5-year solutions with the combined 10-year solution to assess the internal stability and the time evolution of the SLR reference frame; (4) a comparison of the SLR reference frame with ITRF97; and (5) a comparison of SLR station velocities with those of ITRF97 and NNR NUVEL-1A.
Masala, Silvia; Ahmed, Trifa; Bergvall, Christoffer; Westerholm, Roger
2011-12-01
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Peddie, N.W.; Zunde, A.K.
1985-01-01
The new International Geomagnetic Reference Field (IGRF) model of the main geomagnetic field for 1980 is based heavily on measurements from the MAGSAT satellite survey. Assessment of the accuracy of the new model, as a description of the main field near the Earth's surface, is important because the accuracy of models derived from satellite data can be adversely affected by the magnetic field of electric currents in the ionosphere and the auroral zones. Until now, statements about its accuracy have been based on the 6 published assessments of the 2 proposed models from which it was derived. However, those assessments were either regional in scope or were based mainly on preliminary or extrapolated data. Here we assess the near-surface accuracy of the new model by comparing it with values for 1980 derived from annual means from 69 magnetic observatories, and by comparing it with WC80, a model derived from near-surface data. The comparison with observatory-derived data shows that the new model describes the field at the 69 observatories about as accurately as would a model derived solely from near-surface data. The comparison with WC80 shows that the 2 models agree closely in their description of D and I near the surface. These comparisons support the proposition that the new IGRF 1980 main-field model is a generally accurate description of the main field near the Earth's surface in 1980. ?? 1985.
Zhang, Li; Wu, Yuhua; Wu, Gang; Cao, Yinglong; Lu, Changming
2014-10-01
Plasmid calibrators are increasingly applied for polymerase chain reaction (PCR) analysis of genetically modified organisms (GMOs). To evaluate the commutability between plasmid DNA (pDNA) and genomic DNA (gDNA) as calibrators, a plasmid molecule, pBSTopas, was constructed, harboring a Topas 19/2 event-specific sequence and a partial sequence of the rapeseed reference gene CruA. Assays of the pDNA showed similar limits of detection (five copies for Topas 19/2 and CruA) and quantification (40 copies for Topas 19/2 and 20 for CruA) as those for the gDNA. Comparisons of plasmid and genomic standard curves indicated that the slopes, intercepts, and PCR efficiency for pBSTopas were significantly different from CRM Topas 19/2 gDNA for quantitative analysis of GMOs. Three correction methods were used to calibrate the quantitative analysis of control samples using pDNA as calibrators: model a, or coefficient value a (Cva); model b, or coefficient value b (Cvb); and the novel model c or coefficient formula (Cf). Cva and Cvb gave similar estimated values for the control samples, and the quantitative bias of the low concentration sample exceeded the acceptable range within ±25% in two of the four repeats. Using Cfs to normalize the Ct values of test samples, the estimated values were very close to the reference values (bias -13.27 to 13.05%). In the validation of control samples, model c was more appropriate than Cva or Cvb. The application of Cf allowed pBSTopas to substitute for Topas 19/2 gDNA as a calibrator to accurately quantify the GMO.
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
Meng, Ling-hui; Luo, Na; Cheng, Hong; Hou, Dong-qing; Zhao, Xiao-yuan; Mi, Jie
2011-08-01
To compare the optimal references of waist circumference (WC) between Beijing and China in detecting cardiovascular risk factors in school-age children. Percentile curves for WC were drawn by sex using LMS method based on 21 787 children and adolescents aged 7 - 18 from Beijing Child and Adolescent Metabolic Syndrome Study. The 75(th) and the 90(th) percentiles by age and by gender of WC percentile curves were chosen as the optimal WC reference for 3 - 18 years old children and adolescents in Beijing. The sensitivities (Se) and specificities (Sp) were compared between Beijing and China WC references based on the evaluation of cardiovascular risk factors including hypertension, dyslipidemia, impaired fasting glucose and non-alcoholic fatty liver disease (NAFLD) in the test population being composed of 4927 school children aged 7 - 18 years. The predictive values for those cardiovascular risk factors were compared between the two optimal thresholds through comparison of the odds ratio (OR) in regression analysis. The optimal reference for Beijing children and adolescents aged 3 - 18 years ranged from 51.8 to 78.2 cm for the 75(th) percentile in boys and 50.8 to 72.1 cm in girls, and the 90(th) percentile increased from 54.0 to 86.0 cm in boys and 53.3 to 77.3 cm in girls. The Ses of Beijing and China WC references in detecting hypertension were 0.74 and 0.82 in boys and 0.68 and 0.73 in girls; the Ses were 0.69 and 0.80 in detecting low-high density lipoprotein in boys and 0.64 and 0.71 in girls; and they were 0.98 and 1.00 in boys and both were 0.93 in girls for NAFLD. The Sps of Beijing and China WC references in screening hypertension were 0.62 and 0.53 in boys and 0.68 and 0.63 in girls, respectively. In predicting low-high density lipoprotein, the Sps were 0.59 and 0.50 in boys and 0.66 and 0.61 in girls, the Sps were 0.60 and 0.50 in boys and 0.56 and 0.51 in girls for predicting NAFLD. After adjustment for age and gender, ORs and their 95% credibility intervals (CI) of the 90(th) WC percentiles of Beijing and China school children were 6.3 (5.2 - 7.7) and 6.0 (4.9 - 7.4) in predicting hypertension. Both predictive ORs and their 95%CIs were 1.3 (1.1 - 1.5) in predicting impaired fasting glucose and the both were 2.9 (2.5 - 3.4) for dyslipidemia. In predicting NAFLD the ORs and their 95%CIs were 49.1 (12.0 - 201.6) and 69.8 (9.7 - 504.2) for Beijing and China WC optimal references, separately. Compared with Chinese WC reference, WC reference of Beijing had high Sps in screening cardiovascular risk factors in 7 - 18 years old children. The predictive values were not significant different between Beijing and China WC references for almost all cardiovascular risk factors except NAFLD. The WC reference in Beijing was more practical and handy for reference in Beijing and other north developed metropolises.
Kustas, William P.; Moran, M.S.; Jackson, R. D.; Gay, L.W.; Duell, L.F.W.; Kunkel, K.E.; Matthias, A.D.
1990-01-01
Remotely sensed surface temperature and reflectance in the visible and near infrared wavebands along with ancilliary meteorological data provide the capability of computing three of the four surface energy balance components (i.e., net radiation, soil heat flux, and sensible heat flux) at different spatial and temporal scales. As a result, under nonadvective conditions, this enables the estimation of the remaining term (i.e., the latent heat flux). One of the practical applications with this approach is to produce evapotranspiration (ET) maps for agricultural regions which consist of an array of fields containing different crops at varying stages of growth and soil moisture conditions. Such a situation exists in the semiarid southwest at the University of Arizona Maricopa Agricultural Center, south of Phoenix. For one day (14 June 1987), surface temperature and reflectance measurements from an aircraft 150 m above ground level (agl) were acquired over fields from zero to nearly full cover at four times between 1000 MST and 1130 MST. The diurnal pattern of the surface energy balance was measured over four fields, which included alfalfa at 60% cover, furrowed cotton at 20% and 30% cover, and partially plowed what stubble. Instantaneous and daily values of ET were estimated for a representative area around each flux site with an energy balance model that relies on a reference ET. This reference value was determined with remotely sensed data and several meteorological inputs. The reference ET was adjusted to account for the different surface conditions in the other fields using only remotely sensed variables. A comparison with the flux measurements suggests the model has difficulties with partial canopy conditions, especially related to the estimation of the sensible heat flux. The resulting errors for instantaneous ET were on the order of 100 W m-2 and for daily values of order 2 mm day-1. These findings suggest future research should involve development of methods to account for the variability of meteorological parameters brought about by changes in surface conditions and improvements in the modeling of sensible heat transfer across the surface-atmosphere interface for partial canopy conditions using remote sensing information. ?? 1990.
Prettenthaler, Franz; Köberl, Judith; Bird, David Neil
2016-02-01
We extend the concept of 'Weather Value at Risk' - initially introduced to measure the economic risks resulting from current weather fluctuations - to describe and compare sectoral income risks from climate change. This is illustrated using the examples of wheat cultivation and summer tourism in (parts of) Sardinia. Based on climate scenario data from four different regional climate models we study the change in the risk of weather-related income losses between some reference (1971-2000) and some future (2041-2070) period. Results from both examples suggest an increase in weather-related risks of income losses due to climate change, which is somewhat more pronounced for summer tourism. Nevertheless, income from wheat cultivation is at much higher risk of weather-related losses than income from summer tourism, both under reference and future climatic conditions. A weather-induced loss of at least 5% - compared to the income associated with average reference weather conditions - shows a 40% (80%) probability of occurrence in the case of wheat cultivation, but only a 0.4% (16%) probability of occurrence in the case of summer tourism, given reference (future) climatic conditions. Whereas in the agricultural example increases in the weather-related income risks mainly result from an overall decrease in average wheat yields, the heightened risk in the tourism example stems mostly from a change in the weather-induced variability of tourism incomes. With the extended 'Weather Value at Risk' concept being able to capture both, impacts from changes in the mean and the variability of the climate, it is a powerful tool for presenting and disseminating the results of climate change impact assessments. Due to its flexibility, the concept can be applied to any economic sector and therefore provides a valuable tool for cross-sectoral comparisons of climate change impacts, but also for the assessment of the costs and benefits of adaptation measures. Copyright © 2015 Elsevier B.V. All rights reserved.
Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration
NASA Astrophysics Data System (ADS)
Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.
2012-08-01
In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.
Berdaï, Driss; Hotton, Jean-Michel; Lechat, Philippe
2010-01-01
Drug evaluation is based on comparison. Thus, the choice of the comparator for any new treatment becomes a key issue, especially when there are great differences in medical practice and of use conditions of the comparators depending on the geographical zones and their evolution with time. The choice of the comparators must satisfy sometimes different expectations from the registration authorities and for insurance coverage. The universal comparator that allows answering all the clinical assessment questions does not exist. Placebo, when it can be used, remains a reference for the MA (marketing authorisation) application, but does not exclude the use of the reference drug available on the market and prescribed under optimal efficacy conditions. The reference treatment is sometimes a difficult choice due to the absence of validated therapeutic recommendations or if the recommendations vary depending on the countries. The expansion and international harmonization of prescription guidelines (clinical practice guidelines) would reinforce the robustness and efficiency of clinical research efforts with respect to the relevance of the comparison to reference treatments. This principle also applies to the use of a non-drug comparator when it has been recognized as the reference comparator in the treatment of the pathology in question. In as much as possible, the search for a consensus must also aim at defining in the clinical development recommendations significant thresholds for the size of evaluated effects. Optimization of the information made available after clinical trials could also be helped by the development of use of methodologies that allow assessing superiority on secondary criteria during a non-inferiority study on the main criterion. Finally, the development of early scientific consultations by the Haute Autorité de Santé (HAS, French Health Authority) would contribute to adapt phase III clinical trials better to questions concerning the assessment of the clinical added value of the medicinal products evaluated. © 2010 Société Française de Pharmacologie et de Thérapeutique.
Nutritional status in sick children and adolescents is not accurately reflected by BMI-SDS.
Fusch, Gerhard; Raja, Preeya; Dung, Nguyen Quang; Karaolis-Danckert, Nadina; Barr, Ronald; Fusch, Christoph
2013-01-01
Nutritional status provides helpful information of disease severity and treatment effectiveness. Body mass index standard deviation scores (BMI-SDS) provide an approximation of body composition and thus are frequently used to classify nutritional status of sick children and adolescents. However, the accuracy of estimating body composition in this population using BMI-SDS has not been assessed. Thus, this study aims to evaluate the accuracy of nutritional status classification in sick infants and adolescents using BMI-SDS, upon comparison to classification using percentage body fat (%BF) reference charts. BMI-SDS was calculated from anthropometric measurements and %BF was measured using dual-energy x-ray absorptiometry (DXA) for 393 sick children and adolescents (5 months-18 years). Subjects were classified by nutritional status (underweight, normal weight, overweight, and obese), using 2 methods: (1) BMI-SDS, based on age- and gender-specific percentiles, and (2) %BF reference charts (standard). Linear regression and a correlation analysis were conducted to compare agreement between both methods of nutritional status classification. %BF reference value comparisons were also made between 3 independent sources based on German, Canadian, and American study populations. Correlation between nutritional status classification by BMI-SDS and %BF agreed moderately (r (2) = 0.75, 0.76 in boys and girls, respectively). The misclassification of nutritional status in sick children and adolescents using BMI-SDS was 27% when using German %BF references. Similar rates observed when using Canadian and American %BF references (24% and 23%, respectively). Using BMI-SDS to determine nutritional status in a sick population is not considered an appropriate clinical tool for identifying individual underweight or overweight children or adolescents. However, BMI-SDS may be appropriate for longitudinal measurements or for screening purposes in large field studies. When accurate nutritional status classification of a sick patient is needed for clinical purposes, nutritional status will be assessed more accurately using methods that accurately measure %BF, such as DXA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meadows, J.; Smith, D.; Greenwood, L.
Four sample packets containing elemental Ti, Fe, Ni, Cu, Nb, Ag, Eu, Tb and Hf have been irradiated in three distinct accelerator neutron fields, at Argonne National Laboratory and Los Alamos National Laboratory, USA, and Japan Atomic Energy Research Institute, Tokai, Japan. The acquired experimental data include differential cross sections and integral cross sections for the continuum neutron spectrum produced by 7-MeV deuterons incident on thick Be-metal target. The U-238(n,f) cross section was also measured at 10.3 MeV as a consistency check on the experimental technique. This the third progress report on a project which has been carried out undermore » the auspices of an IAEA Coordinated Research Program entitled ``Activation Cross Sections for the Generation Of Long-lived Radionuclides of Importance in Fusion Reactor Technology``. The present report provides the latest results from this work. Comparison is made between the 14.7-MeV cross-section values obtained from the separate investigations at Argonne and JAERI. Generally, good agreement observed within the experimental errors when consistent sample parameters, radioactivity decay data and reference cross values are employed. A comparison is also made between the experimental results and those derived from calculations using a nuclear model. Experimental neutron information on the Be(d,n) neutron spectrum was incorporated in the comparisons for the integral results. The agreement is satisfactory considering the various uncertainties that are involved.« less
Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi
2013-07-01
Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and presented separately for clinically different categories, e.g., hypoglycemia, exercise, or night and day. © 2013 Diabetes Technology Society.
Abnormal cerebrospinal fluid protein indices in schizophrenia.
Kirch, D G; Kaufmann, C A; Papadopoulos, N M; Martin, B; Weinberger, D R
1985-10-01
Determinations of albumin and immunoglobulin G (IgG) were performed in paired cerebrospinal fluid (CSF) and serum samples from 24 subjects with schizophrenia. These determinations allowed calculation of two indices, one that is an indicator of integrity of the blood-brain barrier and the other a measure of selective IgG production within the central nervous system (CNS). In comparison with previously determined reference values, 7 of 24 (29%) subjects showed increased blood-brain barrier permeability, and 8 of 24 (33%) demonstrated elevated endogenous CNS IgG production. One of these eight also demonstrated oligoclonal banding on high-resolution protein electrophoresis of the CSF.
High accuracy OMEGA timekeeping
NASA Technical Reports Server (NTRS)
Imbier, E. A.
1982-01-01
The Smithsonian Astrophysical Observatory (SAO) operates a worldwide satellite tracking network which uses a combination of OMEGA as a frequency reference, dual timing channels, and portable clock comparisons to maintain accurate epoch time. Propagational charts from the U.S. Coast Guard OMEGA monitor program minimize diurnal and seasonal effects. Daily phase value publications of the U.S. Naval Observatory provide corrections to the field collected timing data to produce an averaged time line comprised of straight line segments called a time history file (station clock minus UTC). Depending upon clock location, reduced time data accuracies of between two and eight microseconds are typical.
Flameless atomic-absorption determination of gold in geological materials
Meier, A.L.
1980-01-01
Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.
Designing image segmentation studies: Statistical power, sample size and reference standard quality.
Gibson, Eli; Hu, Yipeng; Huisman, Henkjan J; Barratt, Dean C
2017-12-01
Segmentation algorithms are typically evaluated by comparison to an accepted reference standard. The cost of generating accurate reference standards for medical image segmentation can be substantial. Since the study cost and the likelihood of detecting a clinically meaningful difference in accuracy both depend on the size and on the quality of the study reference standard, balancing these trade-offs supports the efficient use of research resources. In this work, we derive a statistical power calculation that enables researchers to estimate the appropriate sample size to detect clinically meaningful differences in segmentation accuracy (i.e. the proportion of voxels matching the reference standard) between two algorithms. Furthermore, we derive a formula to relate reference standard errors to their effect on the sample sizes of studies using lower-quality (but potentially more affordable and practically available) reference standards. The accuracy of the derived sample size formula was estimated through Monte Carlo simulation, demonstrating, with 95% confidence, a predicted statistical power within 4% of simulated values across a range of model parameters. This corresponds to sample size errors of less than 4 subjects and errors in the detectable accuracy difference less than 0.6%. The applicability of the formula to real-world data was assessed using bootstrap resampling simulations for pairs of algorithms from the PROMISE12 prostate MR segmentation challenge data set. The model predicted the simulated power for the majority of algorithm pairs within 4% for simulated experiments using a high-quality reference standard and within 6% for simulated experiments using a low-quality reference standard. A case study, also based on the PROMISE12 data, illustrates using the formulae to evaluate whether to use a lower-quality reference standard in a prostate segmentation study. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
USE OF FAST GC/TOFMS AS REFERENCE STANDARD FOR FIELD COMPARISON STUDIES WITH ON-SITE INSTRUMENTS
A faster reference standard for field comparison studies of portable gas chromatographs (PGC) is needed. A performance evaluation of a high-speed GCMS (FGC/MS) system conducted during 1998 demonstrated generally satisfactory performance, but it was evident that performance of b...
Passive RFID Rotation Dimension Reduction via Aggregation
NASA Astrophysics Data System (ADS)
Matthews, Eric
Radio Frequency IDentification (RFID) has applications in object identification, position, and orientation tracking. RFID technology can be applied in hospitals for patient and equipment tracking, stores and warehouses for product tracking, robots for self-localisation, tracking hazardous materials, or locating any other desired object. Efficient and accurate algorithms that perform localisation are required to extract meaningful data beyond simple identification. A Received Signal Strength Indicator (RSSI) is the strength of a received radio frequency signal used to localise passive and active RFID tags. Many factors affect RSSI such as reflections, tag rotation in 3D space, and obstacles blocking line-of-sight. LANDMARC is a statistical method for estimating tag location based on a target tag's similarity to surrounding reference tags. LANDMARC does not take into account the rotation of the target tag. By either aggregating multiple reference tag positions at various rotations, or by determining a rotation value for a newly read tag, we can perform an expected value calculation based on a comparison to the k-most similar training samples via an algorithm called K-Nearest Neighbours (KNN) more accurately. By choosing the average as the aggregation function, we improve the relative accuracy of single-rotation LANDMARC localisation by 10%, and any-rotation localisation by 20%.
[Modernized study on eye's signs of blood-stasis syndrome].
Wu, Rui; Xie, Jian-xiang; Zhao, Feng-da
2011-03-01
To make out a computerized formula to diagnose eye's signs of blood-stasis syndrome (BSS), and to improve the previous diagnostic methods by naked eyes. The formula was created by detecting and analyzing the changes of eye's signs in 544 patients (261 of non-BSS and 283 of BSS) quantitatively, adopting computer's color scale principle. And the sensitivity, specificity and accuracy of the formula were verified in 382 patients (97 non-BSS and 285 of BSS). The computerized integral was compared with the naked eye integral, and the normal reference value was calculated with percentile. Various observatory indices of eye's sign were positively correlated with BSS. The specificity of the computerized method was 83.5%, and the diagnostic sensitivity was 89.8%, the accuracy 88.2%, and the correct index 0.733. Comparisons between the computerized integral method and the naked eye integral method showed significant difference in patients of non-BSS or of BSS in various degrees (including mild, moderate and severe) (P < 0.01). The reference value of the naked eye method was below 15. The computerized formula of eye's signs has higher specificity and sensitivity in the diagnosis of BSS, while the naked eye integral method is proved to be useful.
PV systems photoelectric parameters determining for field conditions and real operation conditions
NASA Astrophysics Data System (ADS)
Shepovalova, Olga V.
2018-05-01
In this work, research experience and reference documentation have been generalized related to PV systems photoelectric parameters (PV array output parameters) determining. The basic method has been presented that makes it possible to determine photoelectric parameters with the state-of-the-art reliability and repeatability. This method provides an effective tool for PV systems comparison and evaluation of PV system parameters that the end-user will have in the course of its real operation for compliance with those stipulated in reference documentation. The method takes in consideration all parameters that may possibly affect photoelectric performance and that are supported by sufficiently valid procedures for their values testing. Test conditions, requirements for equipment subject to tests and test preparations have been established and the test procedure for fully equipped PV system in field tests and in real operation conditions has been described.
NASA Astrophysics Data System (ADS)
Chatterjee, Krishnendu; Roy, Deboshree; Tuli, Suneet
2017-05-01
This paper proposes a novel pulse compression algorithm, in the context of frequency modulated thermal wave imaging. The compression filter is derived from a predefined reference pixel in a recorded video, which contains direct measurement of the excitation signal alongside the thermal image of a test piece. The filter causes all the phases of the constituent frequencies to be adjusted to nearly zero value, so that on reconstruction a pulse is obtained. Further, due to band-limited nature of the excitation, signal-to-noise ratio is improved by suppressing out-of-band noise. The result is similar to that of a pulsed thermography experiment, although the peak power is drastically reduced. The algorithm is successfully demonstrated on mild steel and carbon fibre reference samples. Objective comparisons of the proposed pulse compression algorithm with the existing techniques are presented.
A model of geomagnetic secular variation for 1980-1983
Peddie, N.W.; Zunde, A.K.
1987-01-01
We developed an updated model of the secular variation of the main geomagnetic field during 1980 through 1983 based on annual mean values for that interval from 148 worldwide magnetic observatories. The model consists of a series of 80 spherical harmonics, up to and including those of degree and order 8. We used it to form a proposal for the 1985 revision of the International Geomagnetic Reference Field (IGRF). Comparison of the new model, whose mean epoch is approximately 1982.0, with the Provisional Geomagnetic Reference Field for 1975-1980 (PGRF 1975), indicates that the moment of the centered-dipole part of the geomagnetic field is now decreasing faster than it was 5 years ago. The rate (in field units) indicated by PGRF 1975 was about -25 nT a-1, while for the new model it is -28 nT a-1. ?? 1987.
Reliability of reference distances used in photogrammetry.
Aksu, Muge; Kaya, Demet; Kocadereli, Ilken
2010-07-01
To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
Compositional variability of the Martian surface
NASA Technical Reports Server (NTRS)
Adams, John B.; Smith, Milton O.
1991-01-01
Spectral reflectance data from Viking Landers and Orbiters and from telescopic observations were analyzed with the objective of isolating compositional information about the Martian surface and assessing compositional variability. Two approaches were used to calibrate the data to reflectance to permit direct comparisons with laboratory reference spectra of well characterized materials. In Viking Lander multispectral images (six spectral bands) most of the spectral variation is caused by changes in lighting geometry within individual scenes, from scene to scene, and over time. Lighting variations are both wavelength independent and wavelength dependent. By calibrating lander image radiance values to reflectance using spectral mixture analysis, the possible range of compositions was assessed with reference to a collection of laboratory samples, also resampled to the lander spectral bands. All spectra from the lander images studied plot (in six-space) within a planar triangle having at the apexes the respective spectra of tan basaltic palagonite, gray basalt, and shale. Within this plane all lander spectra fit as mixtures of these three endmembers. Reference spectra that plot outside of the triangle are unable to account for the spectral variation observed in the images.
Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy
NASA Astrophysics Data System (ADS)
Marcatili, S.; Pettinato, C.; Daniels, S.; Lewis, G.; Edwards, P.; Fanti, S.; Spezi, E.
2013-04-01
We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In this work, we describe the structure of this application and present the tests performed to validate it against reference data and experiments. We used the spheres of a NEMA phantom to calculate S values and total doses. The comparison with reference data from OLINDA/EXM showed an agreement within 2% for a sphere size above 2.8 cm diameter. A custom heterogeneous phantom composed of several layers of Perspex and lung equivalent material was used to compare TLD measurements of gamma radiation from 131I to Monte Carlo simulations. An agreement within 5% was found. RAYDOSE has been validated against reference data and experimental measurements and can be a useful multi-modality platform for treatment planning and research in MRT.
González Jiménez, E; Aguilar Cordero, M J; Álvarez Ferre, J; Padilla López, C; Valenza, M C
2012-01-01
Recent studies show an alarming increase in levels of overweight and obesity among children and adolescents. The main objectives of this research were the following: (i) to carry out an anthropometric evaluation of the nutritional status and body composition of school children in the city and province of Granada; (ii) to compare the nutritional status of this population sample with national and international reference standards. The results obtained in this study showed that the general prevalence of overweight in both sexes was 22.03% and that 9.12% of the children were obese. Statistically significant differences were found between the variable, weight for age and sex (p < 0.05) and the variable, height for age and sex (p < 0.05). Regarding the body mass index, no statistically significant differences were found for the variable, sex (p = 0.182). This contrasted with the variable, age, which did show statistically significant differences (p < 0.05). As a conclusion, the results of our study highlighted the fact that these anthropometric values were much higher than national and international reference standards.
[Definition and validation of a comfort index calculation method for office seats].
Taboga, P; Marcolin, F; Bordignon, M; Antonutto, G
2012-01-01
Among its other required features, a highly comfortable chair should adapt its contact surfaces, namely the seat and the back rest, to the shape of the body of the person sitting on it. However, "comfort" is not usually perceived as an absolute value, but is derived from a subjective comparison between two or more chairs. The purpose of this research was the definition of an objective comfort index (IC), i.e., derived from instrumental measurements, and which would also represent an absolute comfort value. Analytical evaluation of the distribution of body weight, by means of a barometric matrix, shows that a comfortable chair tends to minimize peak and average values of pressure at the level of the contact areas located between the body and the seat and the back of the chair. To define a comparison parameter for determining an absolute comfort value, a reference chair (SDR) was developed. The seat and the back of this chair are rigid, with poor compliance. A comfort value of zero was, by definition, assigned to this chair. Therefore, the Comfort index (IC) was obtained by the mathematical calculation of the ratios of averages, peaks and gradients of pressure, appropriately weighted, and the corresponding values measured on the tested chair and on the SDR. It is shown that the anthropometric characteristics of each subject are irrelevant to the assessment of the IC, which depends only on the compliance characteristics of the seat and back surfaces of the tested chair IC can be improved through analysis of a larger number of seats, which would thus constitute the basis for the use of an objective evaluation of seating comfort.
Growth status among low-income Mexican and Mexican-American elementary school children.
Winham, Donna M
2012-01-01
Childhood obesity remains a problem among Latino children in the United States. Acculturation to an American diet and sedentary lifestyle may be causative factors. The research purpose was to assess child growth status, including sitting height, in relation to acculturation among Mexican and Mexican-American children. Anthropometric measures of weight, height, and sitting height were taken in a cross-sectional survey of Mexican and Mexican-American elementary school children (N = 484) in Phoenix, Arizona. Height-for-age (HAZ), weight-for-age (WAZ), and body mass index (BMI) Z-scores were calculated based on the Centers for Disease Control 2000 growth reference. Sitting height Z-scores (SHZ) were determined from the NHANES III reference values. Questions about language usage were asked of the children as a proxy for acculturation. Differences in growth measures and acculturation between those born in the United States or Mexico were evaluated by chi-square or t-tests. The mean HAZ value (-0.23) was close to the reference median. There were no significant differences in HAZ or SHZ by birth country or gender. WAZ values for boys were significantly higher than for girls. More girls (64%) than boys (54%) had normal BMIs. More Mexican-born boys (28%) were obese than Mexican-born girls (17%; P = 0.026) in comparison to the US-born boys (31%) and girls (24%; P = n.s.). Acculturation scale score and male gender predicted a small percentage of the variation in BMIZ. Environmental and cultural factors that promote obesity among low-income Mexican and Mexican-American children are similar regardless of birth country but boys may be at greater risk of obesity than girls. Copyright © 2012 Wiley Periodicals, Inc.
Ruaux, Craig; Scollan, Katherine; Suchodolski, Jan S; Steiner, Jörg M; Sisson, D David
2015-09-01
The N-terminal fragment of the prohormone B-type natriuretic peptide (NT-proBNP) and cardiac troponin-I are candidate biomarkers for cardiac disease in dogs. The degree of biologic variation in these biomarkers has not previously been reported in healthy dogs or dogs with mitral regurgitation. The purpose of the study was to derive estimates of intrinsic biologic variability and reference change values for NT-proBNP and cardiac troponin-I in healthy dogs and dogs with mitral regurgitation grade IB and II according to the International Small Animal Cardiac Health Council (ISACHC) grading system. Plasma and sera were collected weekly for up to 7 weeks from 12 control dogs and 9 dogs with mitral regurgitation. NT-proBNP and troponin-I (C-TnI) concentrations were determined. Indices of biologic variation such as reciprocal index of individuality (r-IoI) and reference change values (RCV) were calculated in both the groups. Individuality was high in control dogs and dogs with grade IB and II mitral valve regurgitation for both C-TnI (r-IoI 1.6 and 2) and NT-proBNP (1.5 and 2.7), while the 2-sided RCV for NT-proBNP was significantly lower in dogs with mitral regurgitation (52.5% vs 99.4%, P<0.01.). High individuality of these cardiac biomarkers suggests that, following diagnosis, these assays are best interpreted by serial determination in individual canine patients rather than by comparison to a population-based reference interval. The smaller RCV values for dogs with mitral regurgitation suggest that smaller relative changes in NT-proBNP are clinically meaningful in these patients. © 2015 American Society for Veterinary Clinical Pathology.
ENTROPY VS. ENERGY WAVEFORM PROCESSING: A COMPARISON ON THE HEAT EQUATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, Michael S.; McCarthy, John; Bruillard, Paul J.
2015-05-25
Virtually all modern imaging devices function by collecting either electromagnetic or acoustic backscattered waves and using the energy carried by these waves to determine pixel values that build up what is basically an ”energy” picture. However, waves also carry ”informa- tion” that also may be used to compute the pixel values in an image. We have employed several measures of information, all of which are based on different forms of entropy. Numerous published studies have demonstrated the advantages of entropy, or “information imaging”, over conventional methods for materials characterization and medical imaging. Similar results also have been obtained with microwaves.more » The most sensitive information measure appears to be the joint entropy of the backscattered wave and a reference signal. A typical study is comprised of repeated acquisition of backscattered waves from a specimen that is changing slowing with acquisition time or location. The sensitivity of repeated experimental observations of such a slowly changing quantity may be defined as the mean variation (i.e., observed change) divided by mean variance (i.e., observed noise). We compute the sensitivity for joint entropy and signal energy measurements assuming that noise is Gaussian and using Wiener integration to compute the required mean values and variances. These can be written as solutions to the Heat equation, which permits estimation of their magnitudes. There always exists a reference such that joint entropy has larger variation and smaller variance than the corresponding quantities for signal energy, matching observations of several studies. Moreover, a general prescription for finding an “optimal” reference for the joint entropy emerges, which also has been validated in several studies.« less
Wise, Stephen A; Tai, Susan S-C; Burdette, Carolyn Q; Camara, Johanna E; Bedner, Mary; Lippa, Katrice A; Nelson, Michael A; Nalin, Federica; Phinney, Karen W; Sander, Lane C; Betz, Joseph M; Sempos, Christopher T; Coates, Paul M
2017-09-01
Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.
Advanced Life Support Research and Technology Development Metric: Fiscal Year 2003
NASA Technical Reports Server (NTRS)
Hanford, A. J.
2004-01-01
This document provides the official calculation of the Advanced Life Support (ALS) Research and Technology Development Metric (the Metric) for Fiscal Year 2003. As such, the values herein are primarily based on Systems Integration, Modeling, and Analysis (SIMA) Element approved software tools or reviewed and approved reference documents. The Metric is one of several measures employed by the National Aeronautics and Space Administration (NASA) to assess the Agency s progress as mandated by the United States Congress and the Office of Management and Budget. Because any measure must have a reference point, whether explicitly defined or implied, the Metric is a comparison between a selected ALS Project life support system and an equivalently detailed life support system using technology from the Environmental Control and Life Support System (ECLSS) for the International Space Station (ISS). More specifically, the Metric is the ratio defined by the equivalent system mass (ESM) of a life support system for a specific mission using the ISS ECLSS technologies divided by the ESM for an equivalent life support system using the best ALS technologies. As defined, the Metric should increase in value as the ALS technologies become lighter, less power intensive, and require less volume. For Fiscal Year 2003, the Advanced Life Support Research and Technology Development Metric value is 1.47 for an Orbiting Research Facility and 1.36 for an Independent Exploration Mission.
Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong
2017-05-01
To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.
Subjective Social Status and Well-Being: The Role of Referent Abstraction.
Haught, Heather M; Rose, Jason; Geers, Andrew; Brown, Jill A
2015-01-01
Subjective social status (SSS) has been shown to predict well-being and mental health, above and beyond objective social status (OSS). However, little is known about the factors that moderate this relationship. Two studies explored whether the link between SSS and well-being varied depending upon the referent used for comparison in SSS judgments. Participants judged their well-being and SSS in comparison to referents that varied in abstraction. A confirmatory factor analysis on SSS judgments yielded two factors: (a) SSS perceptions toward global referents and (b) SSS perceptions toward local referents. SSS relative to a global referent was a better predictor of depression (Studies 1 and 2), life satisfaction (Studies 1 and 2), and self-esteem (Study 2) than SSS relative to a local referent. These findings have theoretical implications for understanding how people differentiate between local vs. global referents and practical implications for status-related health disparities.
Final report of the key comparison of APMP.AUV.V-K2
NASA Astrophysics Data System (ADS)
Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui
2017-01-01
A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Final report on regional supplementary comparison SIM.M.FF-S5: Volume of liquids at 50 mL
NASA Astrophysics Data System (ADS)
Morales, Abed; Malta, Dalni; Kornblit, Fernando; Ramírez, Ruben R.; Arias, Roberto; Trujillo, Sonia
2012-01-01
A regional supplementary comparison for the volume of liquid at 50 mL was conducted during October 2009 to June 2010 between the SIM members CENAM, INTI, INMETRO, INDECOPI and INTN. The transfer standard consisted of two 50 mL glass pycnometers, of the Gay Lussac type. CENAM acted as the pilot, collected the measurement results, analyzed the data and produced the comparison report. The median of all participants' results was used to calculate the regional comparison reference value because the result for one of the two pycnometers in one laboratory failed the chi-squared test at the 0.05 probability level. The measurements reported by the participants show an excellent overlap in four out of the five NMIs (-34×10-6 < Di < 29×10-6). The degree of equivalence obtained herein will be taken into account for the preparation of calibration and measurement capabilities claims from the participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
The Study and Measurement of Values and Attitudes.
ERIC Educational Resources Information Center
Kerlinger, Fred N.
The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…
USDA-ARS?s Scientific Manuscript database
Nutrient reference values have significant public health and policy implications. Given the importance of defining reliable nutrient reference values, there is a need for an explicit, objective, and transparent process to set these values. The Tufts Medical Center Evidence-based Practice Center asse...
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
Money and happiness: rank of income, not income, affects life satisfaction.
Boyce, Christopher J; Brown, Gordon D A; Moore, Simon C
2010-04-01
Does money buy happiness, or does happiness come indirectly from the higher rank in society that money brings? We tested a rank-income hypothesis, according to which people gain utility from the ranked position of their income within a comparison group. The rank hypothesis contrasts with traditional reference-income hypotheses, which suggest that utility from income depends on comparison to a social reference-group norm. We found that the ranked position of an individual's income predicts general life satisfaction, whereas absolute income and reference income have no effect. Furthermore, individuals weight upward comparisons more heavily than downward comparisons. According to the rank hypothesis, income and utility are not directly linked: Increasing an individual's income will increase his or her utility only if ranked position also increases and will necessarily reduce the utility of others who will lose rank.
Final report on the key comparison of hydrocarbon liquid flow: CCM.FF-K2.2015
NASA Astrophysics Data System (ADS)
Shimada, T.; Bittner-Rohrhofer, K.; Medina López, V. J.; Arias, R.; Su, C.-M.; Chen, I.-C.; Ribere, F.; Rowan, L.; Dignan, S.
2016-01-01
Seven laboratories: BEV (Austria), CENAM (Mexico), CMS (Chinese-Taipei), LNE-TRAPIL (France), NEL (United Kingdom), NMIA (Australia), and the pilot lab NMIJ (Japan), participated in the key comparison CCM.FF-K2.2015 for hydrocarbon flow measurement. A screw type positive displacement flow meter was selected as a transfer standard. The calibration stability of the transfer standard was evaluated from repeated measurements by NMIJ and showed standard reproducibility of 0.0035 %. The transfer standard was also thoroughly tested for sensitivity to temperature, viscosity, pressure, and other effects. The uncertainty due to the transfer standard of 0.0080 % was less than the quoted uncertainties of the participants. The key comparison reference values (KCRVs) at Reynolds number of 70 000 and 300 000 were obtained as the weighted mean from the calibration results, and the KCRV at Reynolds number of 100 000 was obtained as the median by using the Monte Carlo method according to Cox's procedure B, since the consistency check at Reynolds number of 100 000 failed at the 95 % confidence level. All participant results selected to determine the KCRVs have En values which show consistency with the evaluated KCRVs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
An inter-comparison of surface energy flux measurement systems used during FIFE, 1987
NASA Technical Reports Server (NTRS)
Nie, D.; Kanemasu, E. T.; Fritschen, L. J.; Weaver, H.; Smith, E. A.; Verma, S. B.; Field, R. T.; Kustas, W.; Stewart, J. B.
1990-01-01
During the first International Satellite Land Surface Climatology Program Field Experiment (FIFE-87), surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to nearly all the flux stations to serve as a reference for estimating the instrument related differences. The rover system was installed within a few meters from the host instrument of a site. Net radiation, Bowen ratio, and latent heat fluxes were compared between the rover and the host for the stations visited. Linear regression analysis was used to examine the relationship between rover measurements and host measurements. These inter-comparisons are needed to examine the influence of instrumentation on measurement uncertainty. Highly significant effects of instrument type were detected from these comparisons. Instruments of the same type showed average differences of less than 5 percent for net radiation, 10 percent for Bowen ratio, and 6 percent for latent heat flux. The corresponding average differences for different types of instruments can be up to 10, 30, and 20 percent respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected REBS model. The 4-way components methed and the Thornswaite type give similar values to the REBS. The SERBS type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the AZET systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems.
Context controls access to working and reference memory in the pigeon (Columba livia).
Roberts, William A; Macpherson, Krista; Strang, Caroline
2016-01-01
The interaction between working and reference memory systems was examined under conditions in which salient contextual cues were presented during memory retrieval. Ambient colored lights (red or green) bathed the operant chamber during the presentation of comparison stimuli in delayed matching-to-sample training (working memory) and during the presentation of the comparison stimuli as S+ and S- cues in discrimination training (reference memory). Strong competition between memory systems appeared when the same contextual cue appeared during working and reference memory training. When different contextual cues were used, however, working memory was completely protected from reference memory interference. © 2016 Society for the Experimental Analysis of Behavior.
Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C
1999-10-01
The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.
NASA Astrophysics Data System (ADS)
Aschonitis, Vassilis G.; Papamichail, Dimitris; Demertzi, Kleoniki; Colombani, Nicolo; Mastrocicco, Micol; Ghirardini, Andrea; Castaldelli, Giuseppe; Fano, Elisa-Anna
2017-08-01
The objective of the study is to provide global grids (0.5°) of revised annual coefficients for the Priestley-Taylor (P-T) and Hargreaves-Samani (H-S) evapotranspiration methods after calibration based on the ASCE (American Society of Civil Engineers)-standardized Penman-Monteith method (the ASCE method includes two reference crops: short-clipped grass and tall alfalfa). The analysis also includes the development of a global grid of revised annual coefficients for solar radiation (Rs) estimations using the respective Rs formula of H-S. The analysis was based on global gridded climatic data of the period 1950-2000. The method for deriving annual coefficients of the P-T and H-S methods was based on partial weighted averages (PWAs) of their mean monthly values. This method estimates the annual values considering the amplitude of the parameter under investigation (ETo and Rs) giving more weight to the monthly coefficients of the months with higher ETo values (or Rs values for the case of the H-S radiation formula). The method also eliminates the effect of unreasonably high or low monthly coefficients that may occur during periods where ETo and Rs fall below a specific threshold. The new coefficients were validated based on data from 140 stations located in various climatic zones of the USA and Australia with expanded observations up to 2016. The validation procedure for ETo estimations of the short reference crop showed that the P-T and H-S methods with the new revised coefficients outperformed the standard methods reducing the estimated root mean square error (RMSE) in ETo values by 40 and 25 %, respectively. The estimations of Rs using the H-S formula with revised coefficients reduced the RMSE by 28 % in comparison to the standard H-S formula. Finally, a raster database was built consisting of (a) global maps for the mean monthly ETo values estimated by ASCE-standardized method for both reference crops, (b) global maps for the revised annual coefficients of the P-T and H-S evapotranspiration methods for both reference crops and a global map for the revised annual coefficient of the H-S radiation formula and (c) global maps that indicate the optimum locations for using the standard P-T and H-S methods and their possible annual errors based on reference values. The database can support estimations of ETo and solar radiation for locations where climatic data are limited and it can support studies which require such estimations on larger scales (e.g. country, continent, world). The datasets produced in this study are archived in the PANGAEA database (https://doi.org/10.1594/PANGAEA.868808) and in the ESRN database (http://www.esrn-database.org or http://esrn-database.weebly.com).
Spirometric Reference Equations for Elderly Chinese in Jinan Aged 60–84 Years
Tian, Xin-Yu; Liu, Chun-Hong; Wang, De-Xiang; Ji, Xiu-Li; Shi, Hui; Zheng, Chun-Yan; Xie, Meng-Shuang; Xiao, Wei
2018-01-01
Background: The interpretation of spirometry varies on different reference values. Older people are usually underrepresented in published predictive values. This study aimed at developing spirometric reference equations for elderly Chinese in Jinan aged 60–84 years and to compare them to previous equations. Methods: The project covered all of Jinan city, and the recruitment period lasted 9 months from January 1, 2017 to September 30, 2017, 434 healthy people aged 60–84 years who had never smoked (226 females and 208 males) were recruited to undergo spirometry. Vital capacity (VC), forced VC (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC, FEV1/VC, FEV6, peak expiratory flow, and forced expiratory flow at 25%, 50%, 75%, and 25–75% of FVC exhaled (FEF25%, FEF50%, FEF75%, and FEF25–75%) were analyzed. Reference equations for mean and the lower limit of normal (LLN) were derived using the lambda-mu-sigma method. Comparisons between new and previous equations were performed by paired t-test. Results: New reference equations were developed from the sample. The LLN of FEV1/FVC, FEF25–75% computed using the 2012-Global Lung Function Initiative (GLI) and 2006-Hong Kong equations were both lower than the new equations. The biggest degree of difference for FEV1/FVC was 19% (70.46% vs. 59.29%, t = 33.954, P < 0.01) and for maximal midexpiratory flow (MMEF, equals to FEF25–75%) was 22% (0.82 vs. 0.67, t = 21.303, P < 0.01). The 1990-North China and 2009-North China equations predicted higher mean values of FEV1/FVC and FEF25–75% than the present model. The biggest degrees of difference were −4% (78.31% vs. 81.27%, t = −85.359, P < 0.01) and −60% (2.11 vs. 4.68, t = −170.287, P < 0.01), respectively. Conclusions: The newly developed spirometric reference equations are applicable to elderly Chinese in Jinan. The 2012-GLI and 2006-Hong Kong equations may lead to missed diagnoses of obstructive ventilatory defects and the small airway dysfunction, while traditional linear equations for all ages may lead to overdiagnosis. PMID:29553052
Linking results of key and supplementary comparisons of AC/DC voltage transfer references
NASA Astrophysics Data System (ADS)
Velychko, Oleh
2018-04-01
A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.
Cuspal Deflection of Premolars Restored with Bulk-Fill Composite Resins.
Behery, Haytham; El-Mowafy, Omar; El-Badrawy, Wafa; Saleh, Belal; Nabih, Sameh
2016-01-01
This in vitro study compared cuspal deflection of premolars restored with three bulk-fill composite resins to that of incrementally-restored ones with a low-shrinkage silorane-based restorative material. Forty freshly-extracted intact human upper premolars were used. Reference points at buccal and palatal cusp tips were acid-etched and composite rods were horizontally bonded to them (TPH-Spectra-HV, Dentsply). Two acrylic resin guiding paths were made for each premolar to guide beaks of a digital micrometer used for cuspal deflection measurements. Standardized MOD cavities, 3 mm wide bucco-lingually and 3.5 mm deep, were prepared on each premolar. Prepared teeth were then equally divided into four groups (n = 10) and each group was assigned to one of four composite resin (QuiXX, Dentsply; X-tra fil, Voco; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; low-shrinkage Filtek LS, 3M/ESPE). Adper Single Bond-Plus, 3M/ESPE was used with all bulk-fill restoratives. LS-System Adhesive, 3M/ESPE was used with Filtek LS. For each prepared premolar, cuspal deflection was measured in microns as the difference between two readings between reference points before and after restoration completion. Means and SDs were calculated and data statistically-analyzed using One-way ANOVA and Tukey's test. Filtek LS showed the lowest mean cuspal deflection value 6.4(0.84)μm followed by Tetric EvoCeram Bulk Fill 10.1(1.2) μm and X-tra fil 12.4(1.35)μm, while QuiXX showed the highest mean 13(1.05)μm. ANOVA indicated significant difference among mean values of groups (p < 0.001). Tukey's test indicated no significant difference in mean values between QuiXX and X-tra fil (p = 0.637). Tetric EvoCeram Bulk Fill had significantly lower mean cuspal deflection compared with the two other bulk-fill composite resins tested. Filtek LS had the lowest significant mean cuspal deflection in comparison to all tested bulk-fill restoratives. The use of Tetric EvoCeram Bulk fill composite resin restorative for class II MOD cavities resulted in reduced cuspal deflection in comparison to the two other bulk-fill composite resins tested. The silorane-based Filtek LS restorative resulted in the least cuspal deflection in comparison to all tested bulk-fill composite restoratives. © 2016 Wiley Periodicals, Inc.
Cordeiro, F; Baer, I; Robouch, P; Emteborg, H; Can, S Z; Krata, A; Zampella, M; Quétel, C R; Hearn, R; De la Calle, B
2013-01-01
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants' results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment σ^ was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of 'less than' values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.
NASA Astrophysics Data System (ADS)
Kwon, Hyeokjun; Kang, Yoojin; Jang, Junwoo
2017-09-01
Color fidelity has been used as one of indices to evaluate the performance of light sources. Since the Color Rendering Index (CRI) was proposed at CIE, many color fidelity metrics have been proposed to increase the accuracy of the metric. This paper focuses on a comparison of the color fidelity metrics in an aspect of accuracy with human visual assessments. To visually evaluate the color fidelity of light sources, we made a simulator that reproduces the color samples under lighting conditions. In this paper, eighteen color samples of the Macbeth color checker under test light sources and reference illuminant for each of them are simulated and displayed on a well-characterized monitor. With only a spectrum set of the test light source and reference illuminant, color samples under any lighting condition can be reproduced. In this paper, the spectrums of the two LED and two OLED light sources that have similar values of CRI are used for the visual assessment. In addition, the results of the visual assessment are compared with the two color fidelity metrics that include CRI and IES TM-30-15 (Rf), proposed by Illuminating Engineering Society (IES) in 2015. Experimental results indicate that Rf outperforms CRI in terms of the correlation with visual assessment.
Sakai, Hiroaki; Kanamori, Hiroyuki; Arai-Kichise, Yuko; Shibata-Hatta, Mari; Ebana, Kaworu; Oono, Youko; Kurita, Kanako; Fujisawa, Hiroko; Katagiri, Satoshi; Mukai, Yoshiyuki; Hamada, Masao; Itoh, Takeshi; Matsumoto, Takashi; Katayose, Yuichi; Wakasa, Kyo; Yano, Masahiro; Wu, Jianzhong
2014-01-01
Having a deep genetic structure evolved during its domestication and adaptation, the Asian cultivated rice (Oryza sativa) displays considerable physiological and morphological variations. Here, we describe deep whole-genome sequencing of the aus rice cultivar Kasalath by using the advanced next-generation sequencing (NGS) technologies to gain a better understanding of the sequence and structural changes among highly differentiated cultivars. The de novo assembled Kasalath sequences represented 91.1% (330.55 Mb) of the genome and contained 35 139 expressed loci annotated by RNA-Seq analysis. We detected 2 787 250 single-nucleotide polymorphisms (SNPs) and 7393 large insertion/deletion (indel) sites (>100 bp) between Kasalath and Nipponbare, and 2 216 251 SNPs and 3780 large indels between Kasalath and 93-11. Extensive comparison of the gene contents among these cultivars revealed similar rates of gene gain and loss. We detected at least 7.39 Mb of inserted sequences and 40.75 Mb of unmapped sequences in the Kasalath genome in comparison with the Nipponbare reference genome. Mapping of the publicly available NGS short reads from 50 rice accessions proved the necessity and the value of using the Kasalath whole-genome sequence as an additional reference to capture the sequence polymorphisms that cannot be discovered by using the Nipponbare sequence alone. PMID:24578372
Rawluk, Andrea; Ford, Rebecca M; Neolaka, Fendi L; Williams, Kathryn J
2017-01-01
Values can be useful for identifying what is important to individuals and communities, yet there is currently not a coherent way to conceptualize, identify, and organize the breadth of values that can be affected by a natural disaster. This research proposes a conceptual framework for how to conceptualize, identify, and organize values, and proposes a concrete, tangible value called the valued entity. The framework is applied in two studies of bushfire in Victoria, Australia: 112 submissions from individuals to the 2009 Victorian Bushfires Royal Commission and interviews with 30 members of the public in bushfire risk landscapes. Our findings suggest that: what people value ranges from abstract to concrete; prevalent abstract values include benevolence and universalism; prevalent mid-level valued attributes include natural attributes of landscapes and human life and welfare; prevalent valued entities are people and properties close to the person. Comparison between the two studies suggests people with more recent experience with bushfire refer less to the importance of natural places and natural attributes. The conceptual framework can act as a boundary object to facilitate researchers and policy-makers understanding the breadth of values affected by natural disaster events and management actions and how governance can better consider values at different scales. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Bel Hadj Hmida, Y; Tahri, N; Sellami, A; Yangui, N; Jlidi, R; Beyrouti, M I; Krichen, M S; Masmoudi, H
2001-01-01
In order to determine the sensitivity of CEA in the diagnosis of colo-rectal carcinoma, we studied a series of 48 patients with colo-rectal carcinoma (1992-1996). The sensitivity was at 52% with a reference value of 5 ng/ml and 68.7% for a reference value of 2.5 ng/ml. With a reference value of 5 ng/ml, the sensitivity of CEA was at 37% only for patients with colo-rectal carcinoma at Dukes B stage, 66.6% for patients at stage C and 75% for patients at stage D. The dosage of CEA was carried out with a sandwich immunoenzymatic technique in tube. There is no statistic significant correlation between the pre-operative rate of CEA and the localisation of the tumor and its histologic type; in contrast, it was significantly correlated with the ganglionnary metastasis. A significant relationship between the pre-operative rate of CEA and the Dukes stage was found for a reference value of 10 ng/ml but not for a reference value of 5 ng/ml. We calculated the specificity of the CEA for the cancers of colon and rectum which was at 76.98% with a reference value of 5 ng/ml and 86% with a reference value of 10 ng/ml.
Stübinger, Stefan; Waser, Jasmin; Hefti, Thomas; Drechsler, Anika; Sidler, Michéle; Klein, Karina; von Rechenberg, Brigitte; Schlottig, Falko
2015-05-01
The aim of this study was to evaluate the clinical performance of local cancellous bone amelioration by a 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer with two different implant designs on primary stability and after 4 and 12 weeks of healing time. In six sheep, n = 36 implants (TH) with a conditioned, sandblasted, thermal acid-etched micro-rough surface and n = 36 implants (NB) with a highly crystalline and phosphate-enriched anodized titanium oxide surface were placed in the pelvic bone. Using an ultrasound-based process named Constant Amelioration Process (CAP), half of peri-implant trabecular bone structures were locally tested with 70:30 poly-(L-lactide-co-D,L-Lacide) copolymer in both implant groups, TH and NB. The CAP technology employs ultrasonic energy to liquefy 70:30 poly-(L-lactide-co-D,L-Lacide) which enters the inter-trabecular space, leading to local reinforcement of the cancellous bone structure after solidification of the copolymer. The CAP test group was compared with reference implants placed with the conventional site preparation according to the manufacturers' description. Primary stability was assessed by the measurement of torque-in values and implant stability quotient (ISQ; n = 18 per group). Secondary stability was analyzed by biomechanical removal torque testing after 4 and 12 weeks (n = 9 per group). Insertion torque value (23.3 N cm ± 13.6) of reference TH implants demonstrated a statistically significant (P = 0.00) difference in comparison with test TH implants (41.9 N cm ± 19.5). Reference NB implants revealed a statistically significant (P = 0.03) lower insertion torque value (23.7 N cm ± 13.5) than test NB implants (39.7 N cm ± 18.6). ISQ values increased for all implants from initial implant placement until sacrifice at 12 weeks. Reference TH implants tended to result in an increase in torque values from 4 weeks (181.9 N cm ± 22.8) to 12 weeks (225.7 N cm ± 47.4). This trend could be also proven for implants of test sites (4 week: 176.8 N cm ± 24.1; 12 week: 201.5 N cm ± 53.4). For reference, NB implants a non-significant increase in removal torque values from 4 weeks (146. 7 N cm ± 18.0) to 12 weeks (170.2 N cm ± 40.4) was observed. Removal torque values of test NB implants did not increase from 4 weeks (153.3 N cm ± 21.5) to 12 weeks (146.1 N cm ± 37.5). Biomechanical data proved significantly enhanced primary stability of dental implants after local amelioration without long-term sequelae and irrespective of implant design. After 4- and 12-week healing time, removal torque of locally test implants was as high as for control implants, and osseointegration was therefore not influenced by the CAP process. No correlation between ISQ values and torque values was found. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
O’Brien, Michelle; Minniti, Ronaldo; Masinza, Stanslaus Alwyn
2010-01-01
Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray reference radiation beams of energies between 80 kV and 150 kV and in a cesium 137 gamma-ray beam. The reference radiation qualities used for this comparison are described in detail in the ISO 4037 publication.[1] The comparison began in September 2008 and was completed in March 2009. The results reveal the degree to which the participating calibration facility can demonstrate proficiency in transferring air kerma calibrations under the conditions of the said facility at the time of the measurements. The comparison of the calibration coefficients is based on the average ratios of calibration coefficients. PMID:27134777
O'Brien, Michelle; Minniti, Ronaldo; Masinza, Stanslaus Alwyn
2010-01-01
Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray reference radiation beams of energies between 80 kV and 150 kV and in a cesium 137 gamma-ray beam. The reference radiation qualities used for this comparison are described in detail in the ISO 4037 publication.[1] The comparison began in September 2008 and was completed in March 2009. The results reveal the degree to which the participating calibration facility can demonstrate proficiency in transferring air kerma calibrations under the conditions of the said facility at the time of the measurements. The comparison of the calibration coefficients is based on the average ratios of calibration coefficients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel
2011-03-15
Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult malemore » and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.« less
Pharmacodynamic comparison of two formulations of Acarbose 100-mg tablets.
Lee, S; Chung, J Y; Hong, K S; Yang, S-H; Byun, S-Y; Lim, H-S; Shin, S-G; Jang, I-J; Yu, K-S
2012-10-01
Acarbose, an α-glycosidase inhibitor, is used to treat diabetic patients. Pharmacokinetic evaluation of acarbose is difficult because <2% is absorbed systemically. The current investigation evaluated the bioequivalence of two formulations of acarbose through pharmacodynamic comparison. This investigation consisted of a pilot study and a main study. The pilot study had an open, single-dose, single-sequence design. Subjects received placebo and then two tablets of reference formulation (Glucobay(®) 100 mg tablet; Bayer Healthcare) on two consecutive days with sucrose. The main study was an open, randomized, two-period, two-sequence crossover study. Subjects randomly received placebo and two tablets of either test formulation (generic acarbose 100-mg tablet) or reference formulation with sucrose on two consecutive days in the first period. In the second period, placebo and alternative formulation were administered. Serial blood samples for pharmacodynamic assessment were taken after each administration. The maximum serum glucose concentration (G(max)) and the area under the serum glucose concentration-time profile (AUC(gluc)) were determined and compared. Five subjects completed the pilot study. The AUC(gluc) from dosing until 1 h post-dose (AUC(gluc,1 h)) was significantly different between the placebo and acarbose. A total of 33 subjects completed the main study. The mean differences in G(max) (ΔG(max)) and AUC(gluc,1 h) (ΔAUC(gluc,1 h)) for the reference formulation compared with placebo were 22·0 ± 18·3 mg/dL and 928·2 ± 756·0 mg min/dL, respectively. The corresponding values for the test formulation were 23·3 ± 21·2 mg/dL and 923·0 ± 991·4 0 mg min/dL, respectively. The geometric mean ratios (GMRs) of the test formulation to the reference formulation for ΔG(max) and ΔAUC(gluc, 1 h) were 1·06 and 1·00, respectively, and the 90% confidence intervals (CIs) corresponding values were 0·79-1·39 and 0·64-1·36, respectively. The 90% CIs of GMRs for the pharmacodynamic parameters chosen for bioequivalence evaluation of two formulations of acarbose did not meet the commonly accepted regulatory criteria for bioequivalence (0·80-1·25). © 2012 Blackwell Publishing Ltd.
Barreto, Leonardo Bruno Paz Ferreira; Lourenço, Maria Cristina da Silva; Rolla, Valéria Cavalcanti; Veloso, Valdiléia Gonçalves; Huf, Gisele
2014-01-01
To compare the accuracy of the amplified Mycobacterium tuberculosis direct (AMTD) test with reference methods for the laboratory diagnosis of tuberculosis in HIV-infected patients. This was a study of diagnostic accuracy comparing AMTD test results with those obtained by culture on Löwenstein-Jensen (LJ) medium and by the BACTEC Mycobacteria Growth Indicator Tube 960 (BACTEC MGIT 960) system in respiratory samples analyzed at the Bioassay and Bacteriology Laboratory of the Oswaldo Cruz Foundation Evandro Chagas Clinical Research Institute in the city of Rio de Janeiro, Brazil. We analyzed respiratory samples collected from 118 patients, of whom 88 (74.4%) were male. The mean age was 36.6 ± 10.6 years. Using the AMTD test, the BACTEC MGIT 960 system, and LJ culture, we identified M. tuberculosis complex in 31.0%, 29.7%, and 27.1% of the samples, respectively. In comparison with LJ culture, the AMTD test had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.5%, 89.4%, 75.7%, and 95.0%, respectively, for LJ culture, whereas, in comparison with the BACTEC MGIT 960 system, it showed values of 88.6%, 92.4%, 83.8%, and 94.8%, respectively. The AMTD test showed good sensitivity and specificity in the population studied, enabling the laboratory detection of M. tuberculosis complex in paucibacillary respiratory specimens.
The Q Continuum: Encounter with the Cloud Mask
NASA Astrophysics Data System (ADS)
Ackerman, S. A.; Frey, R.; Holz, R.; Philips, C.; Dutcher, S.
2017-12-01
We are developing a common cloud mask for MODIS and VIIRS observations, referred to as the MODIS VIIRS Continuity Mask (MVCM). Our focus is on extending the MODIS-heritage cloud detection approach in order to generate appropriate climate data records for clouds and climate studies. The MVCM is based on heritage from the MODIS cloud mask (MOD35 and MYD35) and employs a series of tests on MODIS reflectances and brightness temperatures. Cloud detection is based on contrasts (i.e., cloud versus background surface) at pixel resolution. The MVCM follows the same approach. These cloud masks use multiple cloud detection tests to indicate the confidence level that the observation is of a clear-sky scene. The outcome of a test ranges from 0 (cloudy) to 1 (clear-sky scene). Because of overlap in the sensitivities of the various spectral tests to the type of cloud, each test is considered in one of several groups. The final cloud mask is determined from the product of the minimum confidence of each group and is referred to as the Q value as defined in Ackerman et al (1998). In MOD35 and MYD35 processing, the Q value is not output, rather predetermined Q values determine the result: If Q ≥ .99 the scene is clear; .95 ≤ Q < .99 the pixel is probably a clear scene, .66 ≤ Q < .95 is probably cloudy and Q < .66 is cloudy. Thus representing Q discretely and not as a continuum. For the MVCM, the numerical value of the Q is output along with the classification of clear, probably clear, probably cloudy, and cloudy. Through comparisons with collocated CALIOP and MODIS observations, we will assess the categorization of the Q values as a function of scene type ). While validation studies have indicated the utility and statistical correctness of the cloud mask approach, the algorithm does not possess immeasurable power and perfection. This comparison will assess the time and space dependence of Q and assure that the laws of physics are followed, at least according to normal human notions. Using CALIOP as representing truth, a receiver operating characteristic curve (ROC) will be analyzed to determine the optimum Q for various scenes and seasons, thus providing a continuum of discriminating thresholds.
Technical performance of lactate biosensors and a test-strip device during labour.
Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W
2010-04-01
Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an increase of SD and coefficient of variation in all devices. This results in the important preanalytical finding that the precision of replicated measurements worsens significantly with time. The clinician should be aware of the type of analyser used and of preanalytical biases before making clinical decisions on the basis of lactate values.
Optical Fiber Power Meter Comparison Between NIST and NIM.
Vayshenker, I; Livigni, D J; Li, X; Lehman, J H; Li, J; Xiong, L M; Zhang, Z X
2010-01-01
We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and National Institute of Metrology (NIM-China). We report optical fiber-based power measurements at nominal wavelengths of 1310 nm and 1550 nm. We compare the laboratories' reference standards by means of a commercial optical power meter. Measurement results showed the largest difference of less than 2.6 parts in 10(3), which is within the combined standard (k = 1) uncertainty for the laboratories' reference standards.
Precise Orbital and Geodetic Parameter Estimation using SLR Observations for ILRS AAC
NASA Astrophysics Data System (ADS)
Kim, Young-Rok; Park, Eunseo; Oh, Hyungjik Jay; Park, Sang-Young; Lim, Hyung-Chul; Park, Chandeok
2013-12-01
In this study, we present results of precise orbital geodetic parameter estimation using satellite laser ranging (SLR) observations for the International Laser Ranging Service (ILRS) associate analysis center (AAC). Using normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 in SLR consolidated laser ranging data format, the NASA/ GSFC GEODYN II and SOLVE software programs were utilized for precise orbit determination (POD) and finding solutions of a terrestrial reference frame (TRF) and Earth orientation parameters (EOPs). For POD, a weekly-based orbit determination strategy was employed to process SLR observations taken from 20 weeks in 2013. For solutions of TRF and EOPs, loosely constrained scheme was used to integrate POD results of four geodetic SLR satellites. The coordinates of 11 ILRS core sites were determined and daily polar motion and polar motion rates were estimated. The root mean square (RMS) value of post-fit residuals was used for orbit quality assessment, and both the stability of TRF and the precision of EOPs by external comparison were analyzed for verification of our solutions. Results of post-fit residuals show that the RMS of the orbits of LAGEOS-1 and LAGEOS-2 are 1.20 and 1.12 cm, and those of ETALON-1 and ETALON-2 are 1.02 and 1.11 cm, respectively. The stability analysis of TRF shows that the mean value of 3D stability of the coordinates of 11 ILRS core sites is 7.0 mm. An external comparison, with respect to International Earth rotation and Reference systems Service (IERS) 08 C04 results, shows that standard deviations of polar motion XP and YP are 0.754 milliarcseconds (mas) and 0.576 mas, respectively. Our results of precise orbital and geodetic parameter estimation are reasonable and help advance research at ILRS AAC.
Omar, Hazim; Ahmad, Alwani Liyan; Hayashi, Noburo; Idris, Zamzuri; Abdullah, Jafri Malin
2015-12-01
Magnetoencephalography (MEG) has been extensively used to measure small-scale neuronal brain activity. Although it is widely acknowledged as a sensitive tool for deciphering brain activity and source localisation, the accuracy of the MEG system must be critically evaluated. Typically, on-site calibration with the provided phantom (Local phantom) is used. However, this method is still questionable due to the uncertainty that may originate from the phantom itself. Ideally, the validation of MEG data measurements would require cross-site comparability. A simple method of phantom testing was used twice in addition to a measurement taken with a calibrated reference phantom (RefPhantom) obtained from Elekta Oy of Helsinki, Finland. The comparisons of two main aspects were made in terms of the dipole moment (Qpp) and the difference in the dipole distance from the origin (d) after the tests of statistically equal means and variance were confirmed. The result of Qpp measurements for the LocalPhantom and RefPhantom were 978 (SD24) nAm and 988 (SD32) nAm, respectively, and were still optimally within the accepted range of 900 to 1100 nAm. Moreover, the shifted d results for the LocalPhantom and RefPhantom were 1.84 mm (SD 0.53) and 2.14 mm (SD 0.78), respectively, and these values were below the maximum acceptance range of within 5.0 mm of the nominal dipole location. The Local phantom seems to outperform the reference phantom as indicated by the small standard error of the former (SE 0.094) compared with the latter (SE 0.138). The result indicated that HUSM MEG system was in excellent working condition in terms of the dipole magnitude and localisation measurements as these values passed the acceptance limits criteria of the phantom test.
Overall properties of the Gaia DR1 reference frame
NASA Astrophysics Data System (ADS)
Liu, N.; Zhu, Z.; Liu, J.-C.; Ding, C.-Y.
2017-03-01
Aims: The first Gaia data release (Gaia DR1) provides 2191 ICRF2 sources with their positions in the auxiliary quasar solution and five astrometric parameters - positions, parallaxes, and proper motions - for stars in common between the Tycho-2 catalogue and Gaia in the joint Tycho-Gaia astrometric solution (TGAS). We aim to analyze the overall properties of Gaia DR1 reference frame. Methods: We compare quasar positions of the auxiliary quasar solution with ICRF2 sources using different samples and evaluate the influence on the Gaia DR1 reference frame owing to the Galactic aberration effect over the J2000.0-J2015.0 period. Then we estimate the global rotation between TGAS with Tycho-2 proper motion systems to investigate the property of the Gaia DR1 reference frame. Finally, the Galactic kinematics analysis using the K-M giant proper motions is performed to understand the property of Gaia DR1 reference frame. Results: The positional comparison between the auxiliary quasar solution and ICRF2 shows negligible orientation and validates the declination bias of -0.1mas in Gaia quasar positions with respect to ICRF2. Galactic aberration effect is thought to cause an offset 0.01mas of the Z axis direction of Gaia DR1 reference frame. The global rotation between TGAS and Tycho-2 proper motion systems, obtained by different samples, shows a much smaller value than the claimed value 0.24mas yr-1. For the Galactic kinematics analysis of the TGAS K-M giants, we find possible non-zero Galactic rotation components beyond the classical Oort constants: the rigid part ωYG = -0.38±0.15mas yr-1 and the differential part ω^primeYG = -0.29±0.19mas yr-1 around the YG axis of Galactic coordinates, which indicates possible residual rotation in Gaia DR1 reference frame or problems in the current Galactic kinematical model. Conclusions: The Gaia DR1 reference frame is well aligned to ICRF2, and the possible influence of the Galactic aberration effect should be taken into consideration for the future Gaia-ICRF link. The cause of the rather small global rotation between TGAS and Tycho-2 proper motion systems is unclear and needs further investigation. The possible residual rotation in Gaia DR1 reference frame inferred from the Galactic kinematic analysis should be noted and examined in future data release.
Reynolds, B S; Massal, M R; Nguyen, P; Grégoire, L L; Périgaud, A E; Concordet, D; Biourge, V; Lefebvre, H P
2014-10-01
Glomerular filtration rate (GFR) is considered to be the best indicator of overall kidney function. The major objectives of this study were to compare plasma exogenous creatinine clearance (PECC) with a reference method, to establish reference intervals (RIs) for PECC and to assess the effects of indexation of GFR to bodyweight (BW) in cats. PECC was compared with urinary clearance of exogenous creatinine (UECC) in six clinically healthy domestic shorthair cats (experiment 1). Tentative RIs were determined according to current guidelines and the effects of indexation to BW and of covariables on GFR were assessed in 43 clinically healthy cats of various breeds (experiment 2). PECC was 15% higher than UECC (P <0.01), but the two estimates were strongly correlated (r(2)=0.97, P = 0.001). RIs for PECC were 6.4-21.3 mL/min or 1.2-4.9 mL/min/kg. The absolute (i.e. non-indexed) GFR value was not dependent on BW. Thus, indexation of GFR to BW in cats would not standardize the GFR value, but could introduce bias in clinical interpretation. Significant effects of breed, plasma protein concentration and plasma albumin concentration on GFR were demonstrated. Plasma concentrations of urea and creatinine, when assessed separately, were also weakly correlated with GFR in healthy cats. These combined findings contribute to a better understanding of renal function assessment in cats. Copyright © 2014 Elsevier Ltd. All rights reserved.
Eytan, Danny; Goodwin, Andrew J; Greer, Robert; Guerguerian, Anne-Marie; Laussen, Peter C
2017-01-01
Heart rate (HR) and blood pressure (BP) form the basis for monitoring the physiological state of patients. Although norms have been published for healthy and hospitalized children, little is known about their distributions in critically ill children. The objective of this study was to report the distributions of these basic physiological variables in hospitalized critically ill children. Continuous data from bedside monitors were collected and stored at 5-s intervals from 3,677 subjects aged 0-18 years admitted over a period of 30 months to the pediatric and cardiac intensive care units at a large quaternary children's hospital. Approximately 1.13 billion values served to estimate age-specific distributions for these two basic physiological variables: HR and intra-arterial BP. Centile curves were derived from the sample distributions and compared to common reference ranges. Properties such as kurtosis and skewness of these distributions are described. In comparison to previously published reference ranges, we show that children in these settings exhibit markedly higher HRs than their healthy counterparts or children hospitalized on in-patient wards. We also compared commonly used published estimates of hypotension in children (e.g., the PALS guidelines) to the values we derived from critically ill children. This is a first study reporting the distributions of basic physiological variables in children in the pediatric intensive care settings, and the percentiles derived may serve as useful references for bedside clinicians and clinical trials.
Leroy, Frédéric; Müller-Plathe, Florian
2015-08-04
We introduce a methodology, referred to as the dry-surface method, to calculate the work of adhesion of heterogeneous solid-liquid interfaces by molecular simulation. This method employs a straightforward thermodynamic integration approach to calculate the work of adhesion as the reversible work to turn off the attractive part of the actual solid-liquid interaction potential. It is formulated in such a way that it may be used either to evaluate the ability of force fields to reproduce reference values of the work of adhesion or to optimize force-field parameters with reference values of the work of adhesion as target quantities. The methodology is tested in the case of water on a generic model of nonpolar substrates with the structure of gold. It is validated through a quantitative comparison to phantom-wall calculations and against a previous characterization of the thermodynamics of the gold-water interface. It is found that the work of adhesion of water on nonpolar substrates is a nonlinear function of the microscopic solid-liquid interaction energy parameter. We also comment on the ability of mean-field approaches to predict the work of adhesion of water on nonpolar substrates. In addition, we discuss in detail the information on the solid-liquid interfacial thermodynamics delivered by the phantom-wall approach. We show that phantom-wall calculations yield the solid-liquid interfacial tension relative to the solid surface tension rather than the absolute solid-liquid interfacial tension as previously believed.
Kesmarky, Klara; Delhumeau, Cecile; Zenobi, Marie; Walder, Bernhard
2017-07-15
The Glasgow Coma Scale (GCS) and the Abbreviated Injury Score of the head region (HAIS) are validated prognostic factors in traumatic brain injury (TBI). The aim of this study was to compare the prognostic performance of an alternative predictive model including motor GCS, pupillary reactivity, age, HAIS, and presence of multi-trauma for short-term mortality with a reference predictive model including motor GCS, pupil reaction, and age (IMPACT core model). A secondary analysis of a prospective epidemiological cohort study in Switzerland including patients after severe TBI (HAIS >3) with the outcome death at 14 days was performed. Performance of prediction, accuracy of discrimination (area under the receiver operating characteristic curve [AUROC]), calibration, and validity of the two predictive models were investigated. The cohort included 808 patients (median age, 56; interquartile range, 33-71), median GCS at hospital admission 3 (3-14), abnormal pupil reaction 29%, with a death rate of 29.7% at 14 days. The alternative predictive model had a higher accuracy of discrimination to predict death at 14 days than the reference predictive model (AUROC 0.852, 95% confidence interval [CI] 0.824-0.880 vs. AUROC 0.826, 95% CI 0.795-0.857; p < 0.0001). The alternative predictive model had an equivalent calibration, compared with the reference predictive model Hosmer-Lemeshow p values (Chi2 8.52, Hosmer-Lemeshow p = 0.345 vs. Chi2 8.66, Hosmer-Lemeshow p = 0.372). The optimism-corrected value of AUROC for the alternative predictive model was 0.845. After severe TBI, a higher performance of prediction for short-term mortality was observed with the alternative predictive model, compared with the reference predictive model.
Zidi, S; Prat, F; Le Guen, O; Rondeau, Y; Rocher, L; Fritsch, J; Choury, A; Pelletier, G
1999-01-01
Background—Magnetic resonance cholangiography (MRC) is a new technique for non-invasive imaging of the biliary tract. Aim—To assess the results of MRC in patients with suspected bile duct stones as compared with those obtained with reference imaging methods. Patients/Methods—70 patients (34 men and 36 women, mean (SD) age 71 (15.5) years; median 75) with suspected bile duct stones were included (cholangitis, 33; pancreatitis, three; suspected post-cholecystectomy choledocholithiasis, nine; cholestasis, six; stones suspected on ultrasound or computed tomography scan, 19). MR cholangiograms with two dimensional turbo spin echo sequences were acquired. Endoscopic retrograde cholangiography with or without sphincterotomy (n = 63), endosonography (n = 5), or intraoperative cho- langiography (n = 2) were the reference imaging techniques used for the study and were performed within 12 hours of MRC. Radiologists were blinded to the results of endoscopic retrograde cholangiography and previous investigations. Results—49 patients (70%) had bile duct stones on reference imaging (common bile duct, 44, six of which impacted in the papilla; intrahepatic, four; cystic duct stump, one). Stone size ranged from 1 to 20 mm (mean 6.1, median 5.5). Twenty seven patients (55%) had bile duct stones smaller than 6 mm. MRC diagnostic accuracy for bile duct lithiasis was: sensitivity, 57.1%; specificity, 100%; positive predictive value, 100%; negative predictive value, 50%. Conclusions—Stones smaller than 6 mm are still often missed by MRC when standard equipment is used. The general introduction of new technical improvements is needed before this method can be considered reliable for the diagnosis of bile duct stones. Keywords: bile duct calculi; endoscopic retrograde cholangiography; magnetic resonance cholangiography PMID:9862837
Nitrobenzodiazepines: Postmortem brain and blood reference concentrations.
Skov, Louise; Holm, Karen Marie Dollerup; Linnet, Kristian
2016-11-01
Reference concentrations are needed to evaluate postmortem toxicology results and usually femoral blood is the specimen of choice. However, brain tissue has been suggested as a viable alternative specimen, since postmortem blood concentrations can be difficult to interpret due to postmortem redistribution, among other factors. Here we present reference concentrations of postmortem brain and femoral blood of the nitrobenzodiazepines clonazepam, flunitrazepam, and nitrazepam that are of particular interest since they commonly are converted to their corresponding 7-aminometabolites in the postmortem situation. The drugs and metabolites were quantified in both matrices using LC-MS-MS in 69 cases. In 63 cases the compounds were judged not to have been of significance for the death (C cases), whereas they were considered to have been a contributing factor in 6 cases (B cases). No cases were observed with a nitrobenzodiazepine being the sole cause of death (A cases). The brain-blood ratios for clonazepam and nitrazepam were 5.5 and 4.7, respectively, while the brain-blood ratios for the 7-aminometabolites ranged from 0.4 to 0.5. Flunitrazepam only occurred as the 7-aminometabolite. A positive correlation between brain and blood concentrations was found with Spearman's rank correlation coefficients (r s ) ranging from 0.77 to 0.96. The measured femoral blood concentrations agree with literature values, but only few brain concentrations were available for comparison. The drug-metabolite ratios for clonazepam and nitrazepam were 10-12 times higher in brain than in blood. The pre-analytical variation in brain of 5.9% was fairly low, suggesting that brain tissue is a useful alternative to blood. The reported brain and femoral blood concentrations serve as reference values in postmortem investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Loh, Tze Ping; Sethi, Sunil Kumar; Metz, Michael Patrick
2015-08-01
To describe the reference intervals and biological variation data for thyrotropin (TSH) and free thyroxine (FT4) in a mixed Asian population using an indirect sampling approach and to compare them with published reports. TSH and FT4 of children measured once or twice over a 7-year period (2008-2014) at primary-care and tertiary-care settings were extracted from the laboratory information system. After excluding outliers, age-related reference intervals were derived using the Lambda-Mu-Sigma (LMS) approach, while age-partitioned biological variation data were obtained according to recommendations by Fraser and Harris. Both TSH and FT4 were very high at birth and declined with age. Similarly within-individual and between-individual biological variations were higher for both TSH and FT4 at birth and also declined with age. Our data were broadly similar to previous studies. Significant heterogeneity in study population and methods prohibited direct numerical comparison between this and previously published studies. This study fills two important gaps in our knowledge of paediatric thyroid function by reporting the centile trends (and reference values) in a mixed Asian population, as well as providing age-partitioned biological variation data. The variation in published reference intervals highlights the difficulty in harmonising paediatric thyroid reference intervals or recommending universal clinical cut-offs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel
2013-01-01
As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
16 CFR 233.2 - Retail price comparisons; comparable value comparisons.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...
16 CFR 233.2 - Retail price comparisons; comparable value comparisons.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...
16 CFR 233.2 - Retail price comparisons; comparable value comparisons.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...
16 CFR 233.2 - Retail price comparisons; comparable value comparisons.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Retail price comparisons; comparable value... GUIDES AGAINST DECEPTIVE PRICING § 233.2 Retail price comparisons; comparable value comparisons. (a.... Expressed another way, if a number of the principal retail outlets in the area are regularly selling Brand X...
Local tissue air ratio in an anatomic phantom for 60Co total body irradiation.
Vrtar, M; Purisić, A
1991-07-01
Tissue-air ratio (TAR), as the basic dosimetric function, is not ideally applicable to all important locations in total body irradiation (TBI) dosimetry because it generally refers to central ray measurements. We therefore introduced the local TAR which depends on the specific distribution of the scattering centres around the location of interest. Local TAR measurements were performed in an anatomic water phantom, produced by a sculptor, representing a patient during TBI in the real treatment position. A comparison has been made between TAR values, defined on the beam's ray at different locations in the anatomic phantom and cubic phantoms of different size. The local TAR values in the anatomic phantom, having more realistic outer surface curvatures, are lower by a few percent in most locations. We consider these values more accurate and better applicable to TBI conditions than those obtained in cubic water phantoms, even if the volume of the phantom is adapted to the particular side of the body.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
2013-01-01
Background Treatment duration varies with the type of therapy and a patient’s recovery speed. Including such a variation in randomized controlled trials (RCTs) enables comparison of the actual therapeutic potential of different therapies in clinical care. An index, Treatment Duration Control (TDC) of outcome scores was developed to help decide when to end treatment and also to determine treatment outcome by a blinded assessor. In contrast to traditional Routine Outcome Monitoring which considers raw score changes, TDC uses relative change. Methods Our theory shows that if a patient with the largest baseline scores in a sample requires a relative decrease by treatment factor T to reach a zone of low score values (functional status), any patient with smaller baselines will attain functional status with T. Furthermore, the end score values are proportional to the baseline. These characteristics concur with findings from the literature that a patient’s assessment of ‘much improved’ following treatment (related to attaining functional status) is associated with a particular relative decrease in pain intensity yielding a final pain intensity that is proportional to the baseline. Regarding the TDC-procedure: those patient’s scores that were related to pronounced signs and symptoms, were selected for adaptive testing (reference scores). A Contrast-value was determined for each reference score between its reference level and a subsequent level, and averaging all Contrast-values yielded TDC. A cut-off point related to factor T for attaining functional status, was the TDC-criterion to end a patient’s treatment as being successful. The use of TDC has been illustrated in RCT data from 118 chronic pain patients with myogenous Temporomandibular Disorders, and the TDC-criterion was validated. Results The TDC-criterion of successful/unsuccessful treatment approximated the cut-off separating two patient subgroups in a bimodal post-treatment distribution of TDC-values. Pain intensity decreased to residual levels and Health-Related Quality of Life (HRQoL) increased to normal levels, following successful treatment according to TDC. The post-treatment TDC-values were independent from the baseline values of pain intensity or HRQoL, and thus independent from the patient’s baseline severity of myogenous Temporomandibular Disorders. Conclusions TDC enables RCTs that have a variable therapy- and patient-specific duration. PMID:24112821