Maharshi, Vikas; Nagar, Pravesh
2017-01-01
Different forms and online tools are available in different countries for spontaneous reporting, one of the most widely used methods of pharmacovigilance. Capturing sufficient information and adequate compatibility of online systems with respective reporting form is highly desirable for appropriate reporting of adverse drug reactions (ADRs). This study was aimed to compare three major online reporting systems (US, UK, and WHO) of the world and also to check their compatibility with the respective ADR reporting form. A total of 89 data elements to provide relevant information were found out from above three online reporting systems. All three online systems were compared regarding magnitude of information captured by each of them and scoring was done by providing a score of "1" to each element. Compatibility of ADR reporting forms of India (Red form), US (Form 3500), and UK (Yellow card form) was assessed by comparing the information gathered by them with that can be entered into their respective online reporting systems, namely, "VigiFlow," "US online reporting," and "Yellow card online reporting." Each unmatching item was given a score of "-1". VigiFlow scored "74" points, whereas online reporting systems of the US and UK scored "56" and "49," respectively, regarding magnitude of the information gathered by them. Compatibility score was found to be "0," "-9," and "-26" in case of ADR reporting systems of US, UK, and India, respectively. Our study reveals that "VigiFlow" is capable of capturing the maximum amount of information but "Form 3500" and "Online reporting system of US" are maximally compatible to each other among ADR reporting systems of all three countries.
Cooperation, Convertibility, and Compatibility Among Information Systems: A Literature Review.
ERIC Educational Resources Information Center
Henderson, Madeline M.; And Others
The purpose of the study of the literature on which this report is based was to examine those problems in the field of documentation and in the operation of information systems which could possibly be solved or alleviated by some greater measure of cooperation, convertibility, or compatibility among systems, particularly those systems for handling…
Maharshi, Vikas; Nagar, Pravesh
2017-01-01
AIM: Different forms and online tools are available in different countries for spontaneous reporting, one of the most widely used methods of pharmacovigilance. Capturing sufficient information and adequate compatibility of online systems with respective reporting form is highly desirable for appropriate reporting of adverse drug reactions (ADRs). This study was aimed to compare three major online reporting systems (US, UK, and WHO) of the world and also to check their compatibility with the respective ADR reporting form. MATERIALS AND METHODS: A total of 89 data elements to provide relevant information were found out from above three online reporting systems. All three online systems were compared regarding magnitude of information captured by each of them and scoring was done by providing a score of “1” to each element. Compatibility of ADR reporting forms of India (Red form), US (Form 3500), and UK (Yellow card form) was assessed by comparing the information gathered by them with that can be entered into their respective online reporting systems, namely, “VigiFlow,” “US online reporting,” and “Yellow card online reporting.” Each unmatching item was given a score of “−1”. RESULTS: VigiFlow scored “74” points, whereas online reporting systems of the US and UK scored “56” and “49,” respectively, regarding magnitude of the information gathered by them. Compatibility score was found to be “0,” “−9,” and “−26” in case of ADR reporting systems of US, UK, and India, respectively. CONCLUSION: Our study reveals that “VigiFlow” is capable of capturing the maximum amount of information but “Form 3500” and “Online reporting system of US” are maximally compatible to each other among ADR reporting systems of all three countries. PMID:29515278
ERIC Educational Resources Information Center
Boice, John R., Ed.
BSIC has selected data for inclusion, and a method of presentation that-- (1) provides preliminary data, in comparable form, about all relevant systems building products, (2) surveys within the limits imposed, the problems of compatibility between subsystem components and to identify components which are compatible with one another, (3) identifies…
[Practical experience about the compatibility of PDF converter in ECG information system].
Yang, Gang; Lu, Weishi; Zhou, Jiacheng
2009-11-01
To find a way to view ECG from different manufacturers in electrocardiogram information system. Different format ECG data were transmitted to ECG center by different ways. Corresponding analysis software was used to make the diagnosis reports in the center. Then we use PDF convert to change all ECG reports into PDF format. The electrocardiogram information system manage these PDF format ECG data for clinic user. The ECG reports form several major ECG manufacturers were transformed to PDF format successfully. In the electrocardiogram information system it is freely to view the ECG figure. PDF format ECG report is a practicable way to solve the compatibility problem in electrocardiogram information system.
DOT National Transportation Integrated Search
2000-04-01
The Coast Guard funded the National Telecommunications and Information Administration : (NTIA) to perform electromagnetic compatibility (EMC) tests between an ITU-R M. 825-3 : (Characteristics Of a Transponder System Using Digital Selective Calling T...
Geobase Information System Impacts on Space Image Formats
NASA Technical Reports Server (NTRS)
Simonett, D. S. (Editor); Smith, T. R. (Editor); Tobler, W. (Editor); Marks, D. G. (Editor); Frew, J. E. (Editor); Dozier, J. C. (Editor)
1978-01-01
As Geobase Information Systems increase in number, size and complexity, the format compatability of satellite remote sensing data becomes increasingly more important. Because of the vast and continually increasing quantity of data available from remote sensing systems the utility of these data is increasingly dependent on the degree to which their formats facilitate, or hinder, their incorporation into Geobase Information Systems. To merge satellite data into a geobase system requires that they both have a compatible geographic referencing system. Greater acceptance of satellite data by the user community will be facilitated if the data are in a form which most readily corresponds to existing geobase data structures. The conference addressed a number of specific topics and made recommendations.
Jenke, Dennis R
2003-01-01
Delivery systems are used to store, contain, and/or administer liquid pharmaceutical products. Gaining an understanding of the chemical composition of such a delivery system is necessary with respect to effective system development, registration, and production. Additionally, the ability of the delivery system to impact the chemical composition of the contacted product may define the safety and/or efficacy of the product. Assessing the compatibility of the delivery system and the product is thus both necessary and desirable. The nomenclature associated with compatibility assessments has not been standardized, oftimes leading to conflicting or confusing information. This manuscript puts forth a nomenclature which classifies those chemical entities which participate in the system/product interaction and delineates the various extraction strategies which may be used in compatibility assessments.
The Top Six Compatibles: A Closer Look at the Machines That Are Most Compatible with the IBM PC.
ERIC Educational Resources Information Center
McMullen, Barbara E.; And Others
1984-01-01
Reviews six operationally compatible microcomputers that are most able to run IBM software without modifications--Compaq, Columbia, Corona, Hyperion, Eagle PC, and Chameleon. Information given for each includes manufacturer, uses, standard features, base list price, typical system price, and options and accessories. (MBR)
Schoolhouse Systems Project: SSP. 3rd Report.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee.
This brochure provides statistical bid breakdown for Programs 1A and 2 of the Florida Schoolhouse Systems Project. Tabular information is provided on bidders, compatible building subsystems, bid tabulation by compatibility, "per school" building subsystems, nominated bidders and lump sums, and a comparison of programs 1A and 2 bids. Data…
Fujiwara, Yasuhiro; Fujioka, Hitoshi; Watanabe, Tomoko; Sekiguchi, Maiko; Murakami, Ryuji
2017-09-01
Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.
Oxygen fires, materials compatibility and system contaminants
NASA Astrophysics Data System (ADS)
Barter, Simon A.; Hillen, Lance W.
An evaluation is made of aircraft fires initiated by oxygen systems, giving attention to such systems' mechanical design and materials-selection factors. While many oxygen compatibility tests are conducted on single components, operational systems become contaminated through frequent use and occasional abuse; it is therefore essential for the designer to have information about the oxygen compatibility of the entire spectrum of potential contaminants and their various combinations. Valve designs are noted to be especially sensitive to system contamination. Gaseous oxygen fire severity is fundamentally determined by the period of oxygen flow. There is a clear need for an automatic shut-off device which would operate when abnormal flow conditions occur.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...
Aircraft Electromagnetic Compatibility.
1987-06-01
Human Exposure to Radio Frequency Electromagnetic Fields , 300 KiloHertz to 100 GigaHertz." 6. ARINC 429-8, "Digital Information Transfer System (DITS...142 V EXECUTIVE SUMMARY The Aircraft Electromagnetic Compatibility guidelines document deals with electromagnetic compatibility in a... electromagnetic interference paths (figure EI. TYPE PATH 400 Hz Electrostatic MagneticCharge Electric Field Transients 5 R d t Coupling 150/i 300o Wire
7 CFR 274.3 - Issuance systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... processing and information retrieval system and to be presented by, and returned to, recipients at retail... in a manner compatible with its system used for maintaining case record information and shall separate the information on the master issuance file into active and inactive case file categories. The...
Advanced radiology information system.
Kolovou, L; Vatousi, M; Lymperopoulos, D; Koukias, M
2005-01-01
The innovative features of an advanced Radiology Information System (RIS) are presented in this paper. The interoperability of RIS with the other Intra-hospital Information Systems that interacts with, dealing with the compatibility and open architecture issues, are accomplished by two novel mechanisms [1]. The first one is the particular message handling system that is applied for the exchange of information, according to the Health Level Seven (HL7) protocol's specifications and serves the transfer of medical and administrative data among the RIS applications and data store unit. The same mechanism allows the secure and HL7-compatible interactions with the Hospital Information System (HIS) too. The second one implements the translation of information between the formats that HL7 and Digital Imaging and Communication in Medicine (DICOM) protocols specify, providing the communication between RIS and Picture and Archive Communication System (PACS). The whole structure ensures the automation of the every-day procedures that the ;medical protocol' specifies and provides its services through a friendly and easy to manage graphical user interface.
DOT National Transportation Integrated Search
1999-04-22
The CVISN Operational and Architectural Compatibility Handbook (COACH) provides a comprehensive checklist of what is required to conform with the Commercial Vehicle Information Systems and Networks (CVISN) operational concepts and architecture. It is...
Berkő, Péter
2016-05-01
It is a regrettable deficiency in the Hungarian healthcare that the culture and the system of quality control of cure have not been formed (except for a few subspecialties, units or wards). If hospital wards do not have a national, professionally unified and modern information system presenting the most important quantity and quality indicators of their medicinal activity annually, a stable basis for definition of future tasks is absent. The author puts forward a proposal for the establishment of the information systems for different professional fields. On the basis of experience of perinatological information system operating for over 3 decades in Borsod-Abaúj-Zemplén county, he also proposes introduction of a nationally unified, Europeristat-compatible information system following Tauffer-statistics which may serve as a uniform quality control of obstetrics and perinatological care, as well as introduction of its base, the dataform "TePERA" (Form of Obstetrics and Perinatological Care Risk).
Enforcing compatibility and constraint conditions and information retrieval at the design action
NASA Technical Reports Server (NTRS)
Woodruff, George W.
1990-01-01
The design of complex entities is a multidisciplinary process involving several interacting groups and disciplines. There is a need to integrate the data in such environments to enhance the collaboration between these groups and to enforce compatibility between dependent data entities. This paper discusses the implementation of a workstation based CAD system that is integrated with a DBMS and an expert system, CLIPS, (both implemented on a mini computer) to provide such collaborative and compatibility enforcement capabilities. The current implementation allows for a three way link between the CAD system, the DBMS and CLIPS. The engineering design process associated with the design and fabrication of sheet metal housing for computers in a large computer manufacturing facility provides the basis for this prototype system.
ERIC Educational Resources Information Center
National Centre for Vocational Education Research, Leabrook (Australia).
This report presents results of a project to produce a set of strategies to ensure the compatibility of Australian state and territory information systems with the requirements of the National Management Information and Statistics System (NATMISS) and the Australian Vocational Education and Training Management Information Statistical Standard…
Compatibility of Niobium Alloys and Superalloys in a Flowing He-Xe Power Conversion System
NASA Technical Reports Server (NTRS)
Bowman, Cheryl L.; Ritzert, Frank J.; Smialek, James L.; Jaster, Mark L.; rker, Samuel P.
2004-01-01
Proposed concepts for an ambitious mission to explore Jupiter's three icy moons place significant demands on the various spacecraft systems. There are many challenges related to the high output power conversion systems being considered, and one example is the need to ensure system compatibility at all levels. The utilization of appropriate materials for component structures is important to ensuring long mission life. Refractory metal alloys have attractive high-temperature properties in inert environments, but these alloys are sometimes susceptible to contamination. Potential material compatibility issues exist between refractory metal candidates and more conventional alloys. Nb-1Zr has long been considered one of the most well characterized refractory alloys that is well suited for elevated-temperature use and liquid-metal compatibility. However, previous studies have suggested that niobium alloys can not co-exist in a closed system with traditional stainless steels or superalloys due to transport of contaminants. The relevance of this information to a proposed power conversion system is discussed. Also, experiments and fundamental calculations are being performed to determine contamination transport from candidate superalloys to Nb-1Zr in a closed system with an inert carrier gas. Potential protective schemes are explored to ensure system level compatibility between the refractory alloy Nb-1Zr and a nickel-based superalloy.
Review information for UST owners and operators on tribal lands with compatibility requirements in the 2015 federal UST regulation when storing gasoline blends containing greater than 10 percent ethanol or diesel blends containing greater than 20 percent.
NASA Technical Reports Server (NTRS)
Montgomery, O. L.
1977-01-01
Procedures developed for digitizing the transportation arteries, airports, and dock facilities of Alabama and placing them in a computerized format compatible with the Alabama Resource Information System are described. The time required to digitize by the following methods: (a) manual, (b) Telereadex 29 with film reading and digitizing system, and (c) digitizing tablets was evaluated. A method for digitizing and storing information from the U. T. M. grid cell base which was compatible with the system was developed and tested. The highways, navigable waterways, railroads, airports, and docks in the study area were digitized and the data stored. The manual method of digitizing was shown to be best for small amounts of data, while the graphic input from the digitizing tablets would be the best approach for entering the large amounts of data required for an entire state.
Adaptive transmission based on multi-relay selection and rate-compatible LDPC codes
NASA Astrophysics Data System (ADS)
Su, Hualing; He, Yucheng; Zhou, Lin
2017-08-01
In order to adapt to the dynamical changeable channel condition and improve the transmissive reliability of the system, a cooperation system of rate-compatible low density parity check (RC-LDPC) codes combining with multi-relay selection protocol is proposed. In traditional relay selection protocol, only the channel state information (CSI) of source-relay and the CSI of relay-destination has been considered. The multi-relay selection protocol proposed by this paper takes the CSI between relays into extra account in order to obtain more chances of collabration. Additionally, the idea of hybrid automatic request retransmission (HARQ) and rate-compatible are introduced. Simulation results show that the transmissive reliability of the system can be significantly improved by the proposed protocol.
Strategic Planning for Management Information Systems.
ERIC Educational Resources Information Center
Ein-Dor, Phillip; Segev, Eli
1978-01-01
Two factors predominate in determining the appropriateness of strategic plans for management information systems (MIS)--explicitness (the degree to which the process is conscious, formal, and documented) and situational fit (the degree to which the MIS is compatible with the specific organization and its members). (Author/IRT)
76 FR 4456 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
..., computer systems analysis and computer programming services. The contractors promptly return data entry... Use Disclosures of Data in the System The Privacy Act allows us to disclose information without an...) for which the information was collected. Any such compatible use of data is known as a ``routine use...
Conversion of the Aerodynamic Preliminary Analysis System (APAS) to an IBM PC Compatible Format
NASA Technical Reports Server (NTRS)
Kruep, John M.
1995-01-01
The conversion of the Aerodynamic Preliminary Analysis System (APAS) software from a Silicon Graphics UNIX-based platform to a DOS-based IBM PC compatible is discussed. Relevant background information is given, followed by a discussion of the steps taken to accomplish the conversion and a discussion of the type of problems encountered during the conversion. A brief comparison of aerodynamic data obtained using APAS with data from another source is also made.
IRDS prototyping with applications to the representation of EA/RA models
NASA Technical Reports Server (NTRS)
Lekkos, Anthony A.; Greenwood, Bruce
1988-01-01
The requirements and system overview for the Information Resources Dictionary System (IRDS) are described. A formal design specification for a scaled down IRDS implementation compatible with the proposed FIPS IRDS standard is contained. The major design objectives for this IRDS will include a menu driven user interface, implementation of basic IRDS operations, and PC compatibility. The IRDS was implemented using Smalltalk/5 object oriented programming system and an ATT 6300 personal computer running under MS-DOS 3.1. The difficulties encountered in using Smalltalk are discussed.
14 CFR 121.139 - Requirements for manual aboard aircraft: Supplemental operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., it must carry a compatible reading device that produces a legible image of the maintenance information and instructions or a system that is able to retrieve the maintenance information and instructions...
14 CFR 121.139 - Requirements for manual aboard aircraft: Supplemental operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., it must carry a compatible reading device that produces a legible image of the maintenance information and instructions or a system that is able to retrieve the maintenance information and instructions...
Compatibility of information and mode of control: The case for natural control systems
NASA Technical Reports Server (NTRS)
Owen, Dean H.
1993-01-01
The operation of control systems has been determined largely by mechanical constraints. Compatibility with the characteristics of the operator is a secondary consideration, with the result that control may never be optimal, control workload may interfere with performance of secondary tasks, and learning may be more difficult and protracted than necessary. With the introduction of a computer in the control loop, the mode of operation can be adapted to the operator, rather than vice versa. The concept of natural control is introduced to describe a system that supports control of the information used by the operator in achieving an intended goal. As an example, control of speed during simulated approach to a pad by helicopter pilots is used to contrast path-speed control with direct control of global optical flow-pattern information. Differences are evidenced in the performance domains of control activity, speed, and global optical flow velocity.
Evaluating the compatibility of multi-functional and intensive urban land uses
NASA Astrophysics Data System (ADS)
Taleai, M.; Sharifi, A.; Sliuzas, R.; Mesgari, M.
2007-12-01
This research is aimed at developing a model for assessing land use compatibility in densely built-up urban areas. In this process, a new model was developed through the combination of a suite of existing methods and tools: geographical information system, Delphi methods and spatial decision support tools: namely multi-criteria evaluation analysis, analytical hierarchy process and ordered weighted average method. The developed model has the potential to calculate land use compatibility in both horizontal and vertical directions. Furthermore, the compatibility between the use of each floor in a building and its neighboring land uses can be evaluated. The method was tested in a built-up urban area located in Tehran, the capital city of Iran. The results show that the model is robust in clarifying different levels of physical compatibility between neighboring land uses. This paper describes the various steps and processes of developing the proposed land use compatibility evaluation model (CEM).
Double Retort System for Materials Compatibility Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Munne; EV Carelli
2006-02-23
With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contaminationmore » has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented.« less
CD-ROM: Potential and Pitfalls.
ERIC Educational Resources Information Center
Dreiss, L. Jack; Bashir, Shahzad
1990-01-01
Examines issues surrounding CD-ROM as an organizational information management tool: (1) the CD-ROM market; (2) pitfalls, including compatibility, effect on existing information systems, fear of obsolescence, protection of sensitive information, and lack of successful role models; and (3) factors that will fuel growth, including greater…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1998-03-15
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to thermophysical properties, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air conditioning and refrigeration equipment. It also references documents addressing compatibility ofmore » refrigerants and lubricants with other materials.« less
Schleyer, Titus; Spallek, Heiko; Butler, Brian S; Subramanian, Sushmita; Weiss, Daniel; Poythress, M Louisa; Rattanathikun, Phijarana; Mueller, Gregory
2008-08-13
As biomedical research projects become increasingly interdisciplinary and complex, collaboration with appropriate individuals, teams, and institutions becomes ever more crucial to project success. While social networks are extremely important in determining how scientific collaborations are formed, social networking technologies have not yet been studied as a tool to help form scientific collaborations. Many currently emerging expertise locating systems include social networking technologies, but it is unclear whether they make the process of finding collaborators more efficient and effective. This study was conducted to answer the following questions: (1) Which requirements should systems for finding collaborators in biomedical science fulfill? and (2) Which information technology services can address these requirements? The background research phase encompassed a thorough review of the literature, affinity diagramming, contextual inquiry, and semistructured interviews. This phase yielded five themes suggestive of requirements for systems to support the formation of collaborations. In the next phase, the generative phase, we brainstormed and selected design ideas for formal concept validation with end users. Then, three related, well-validated ideas were selected for implementation and evaluation in a prototype. Five main themes of systems requirements emerged: (1) beyond expertise, successful collaborations require compatibility with respect to personality, work style, productivity, and many other factors (compatibility); (2) finding appropriate collaborators requires the ability to effectively search in domains other than your own using information that is comprehensive and descriptive (communication); (3) social networks are important for finding potential collaborators, assessing their suitability and compatibility, and establishing contact with them (intermediation); (4) information profiles must be complete, correct, up-to-date, and comprehensive and allow fine-grained control over access to information by different audiences (information quality and access); (5) keeping online profiles up-to-date should require little or no effort and be integrated into the scientist's existing workflow (motivation). Based on the requirements, 16 design ideas underwent formal validation with end users. Of those, three were chosen to be implemented and evaluated in a system prototype, "Digital|Vita": maintaining, formatting, and semi-automated updating of biographical information; searching for experts; and building and maintaining the social network and managing document flow. In addition to quantitative and factual information about potential collaborators, social connectedness, personal and professional compatibility, and power differentials also influence whether collaborations are formed. Current systems only partially model these requirements. Services in Digital|Vita combine an existing workflow, maintaining and formatting biographical information, with collaboration-searching functions in a novel way. Several barriers to the adoption of systems such as Digital|Vita exist, such as potential adoption asymmetries between junior and senior researchers and the tension between public and private information. Developers and researchers may consider one or more of the services described in this paper for implementation in their own expertise locating systems.
JTIDS electromagnetic compatibility in the 960-1215 MHz band
NASA Astrophysics Data System (ADS)
Lokuta, Robert S.
1992-01-01
The Joint Tactical Information Distribution System (JTIDS) operates in the 960-1215 MHz frequency band. This band is allocated world-wide on a primary basis for aeronautical radio navigation. JTIDS was designed to be electromagnetically compatible with the Air Traffic Control systems that operate in this band. Over the past 15 years, extensive bench tests, flight tests, and analyses were conducted to assess the electromagnetic compatibility (EMC) of JTIDS in the 960-1215 MHz band. This report summarizes the results and conclusions of these efforts, presents some supporting data and provides specific guidance for the operation of JTIDS within the National Air Space. Guidance and recommendations are also provided to assist in the definition and scope of a JTIDS EMC test and analysis effort.
MailMinder: taming DHCP's mailman interface.
Shultz, E K; Brown, R; Kotta, G
1992-01-01
While the Department of Veteran's Affairs Decentralized Hospital Computer Program (DHCP) is one of the most widely disseminated and successful hospital information systems in existence, it currently is accessed through a user interface which is not as mature as the rest of the system. This interface is a VT-100 compatible, character oriented interface using menus accessed by typed commands for feature access. This project demonstrated that a mature graphical user interface (MailMinder) can be successfully used as a "front-end" to DHCP. MailMinder is completely compatible with the existing unmodified DHCP electronic mail program, Mailman. MailMinder allows the user to be more efficient than the current interface and offers additional features over the current mail system. The program has undergone evaluation and limited deployment at five separate sites. The feature set of this program and its operation will be shown at this demonstration. The demonstration has implications for all current hospital information systems.
MailMinder: taming DHCP's mailman interface.
Shultz, E. K.; Brown, R.; Kotta, G.
1992-01-01
While the Department of Veteran's Affairs Decentralized Hospital Computer Program (DHCP) is one of the most widely disseminated and successful hospital information systems in existence, it currently is accessed through a user interface which is not as mature as the rest of the system. This interface is a VT-100 compatible, character oriented interface using menus accessed by typed commands for feature access. This project demonstrated that a mature graphical user interface (MailMinder) can be successfully used as a "front-end" to DHCP. MailMinder is completely compatible with the existing unmodified DHCP electronic mail program, Mailman. MailMinder allows the user to be more efficient than the current interface and offers additional features over the current mail system. The program has undergone evaluation and limited deployment at five separate sites. The feature set of this program and its operation will be shown at this demonstration. The demonstration has implications for all current hospital information systems. PMID:1482995
Pathfinder. Volume 8, Number 6, November/December 2010
2010-12-01
transferring information between multiple systems . Nevertheless, without an end-to-end TCPED process and the associated standards, policies and equipment in...products with partners whose information technology systems vary and are not compatible with those of the NSG, NGA and the U.S. Depart- ment of...Pacific. ARF DReaMS is based on Web service technol- ogy, where traditional maps, data and any relevant geospatial information are made available
The Research on Linux Memory Forensics
NASA Astrophysics Data System (ADS)
Zhang, Jun; Che, ShengBing
2018-03-01
Memory forensics is a branch of computer forensics. It does not depend on the operating system API, and analyzes operating system information from binary memory data. Based on the 64-bit Linux operating system, it analyzes system process and thread information from physical memory data. Using ELF file debugging information and propose a method for locating kernel structure member variable, it can be applied to different versions of the Linux operating system. The experimental results show that the method can successfully obtain the sytem process information from physical memory data, and can be compatible with multiple versions of the Linux kernel.
Spallek, Heiko; Butler, Brian S; Subramanian, Sushmita; Weiss, Daniel; Poythress, M Louisa; Rattanathikun, Phijarana; Mueller, Gregory
2008-01-01
Background As biomedical research projects become increasingly interdisciplinary and complex, collaboration with appropriate individuals, teams, and institutions becomes ever more crucial to project success. While social networks are extremely important in determining how scientific collaborations are formed, social networking technologies have not yet been studied as a tool to help form scientific collaborations. Many currently emerging expertise locating systems include social networking technologies, but it is unclear whether they make the process of finding collaborators more efficient and effective. Objective This study was conducted to answer the following questions: (1) Which requirements should systems for finding collaborators in biomedical science fulfill? and (2) Which information technology services can address these requirements? Methods The background research phase encompassed a thorough review of the literature, affinity diagramming, contextual inquiry, and semistructured interviews. This phase yielded five themes suggestive of requirements for systems to support the formation of collaborations. In the next phase, the generative phase, we brainstormed and selected design ideas for formal concept validation with end users. Then, three related, well-validated ideas were selected for implementation and evaluation in a prototype. Results Five main themes of systems requirements emerged: (1) beyond expertise, successful collaborations require compatibility with respect to personality, work style, productivity, and many other factors (compatibility); (2) finding appropriate collaborators requires the ability to effectively search in domains other than your own using information that is comprehensive and descriptive (communication); (3) social networks are important for finding potential collaborators, assessing their suitability and compatibility, and establishing contact with them (intermediation); (4) information profiles must be complete, correct, up-to-date, and comprehensive and allow fine-grained control over access to information by different audiences (information quality and access); (5) keeping online profiles up-to-date should require little or no effort and be integrated into the scientist’s existing workflow (motivation). Based on the requirements, 16 design ideas underwent formal validation with end users. Of those, three were chosen to be implemented and evaluated in a system prototype, “Digital|Vita”: maintaining, formatting, and semi-automated updating of biographical information; searching for experts; and building and maintaining the social network and managing document flow. Conclusions In addition to quantitative and factual information about potential collaborators, social connectedness, personal and professional compatibility, and power differentials also influence whether collaborations are formed. Current systems only partially model these requirements. Services in Digital|Vita combine an existing workflow, maintaining and formatting biographical information, with collaboration-searching functions in a novel way. Several barriers to the adoption of systems such as Digital|Vita exist, such as potential adoption asymmetries between junior and senior researchers and the tension between public and private information. Developers and researchers may consider one or more of the services described in this paper for implementation in their own expertise locating systems. PMID:18701421
76 FR 4435 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... entry, computer systems analysis and computer programming services. The contractors promptly return data.... Proposed Routine Use Disclosures of Data in the System This System of Records contains information such as... compatible use of data is known as a ``routine use''. The routine uses proposed for this System are...
NASA Technical Reports Server (NTRS)
Hardy, E. E.; Skaley, J. E.; Phillips, E. S.
1974-01-01
This investigation was to develop a low cost, manual technique for enhancing ERTS-1 imagery and preparing it in suitable format for use by users with wide and varied interests related to land use and natural resources information. The goals were: to develop enhancement techniques based on concepts and practices extant in photographic sciences, to provide a means of allowing productive interpretation of the imagery by manual means, to produce a product at low cost, to provide a product that would have wide applications, and one compatible with existing information systems. Cost of preparation of the photographically enhanced, enlarged negatives and positives and the diazo materials is about 1 cent per square mile. Cost of creating and mapping a land use classification of twelve use types at a scale of 1:250,000 is only $1 per square mile. The product is understood by users, is economical, and is compatible with existing information systems.
COSMOS (County of San Mateo Online System). A Searcher's Manual.
ERIC Educational Resources Information Center
San Mateo County Superintendent of Schools, Redwood City, CA. Educational Resources Center.
Operating procedures are explained for COSMOS (County of San Mateo Online System), a computerized information retrieval system designed for the San Mateo Educational Resources Center (SMERC), which provides interactive access to both ERIC and a local file of fugitive documents. COSMOS hardware and modem compatibility requirements are reviewed,…
Overview of GPS Adjacent Band Compatibility Assessment
DOT National Transportation Integrated Search
2014-09-18
January 13, 2012 National SpaceBased Positioning, Navigation, and Timing (PNT) Executive Committee (EXCOM) cochair letter to National Telecommunications and Information Administration (NTIA) proposed to draft new Global Positioning System (GPS)...
14 CFR 91.1023 - Program operating manual requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., it must ensure there is a compatible reading device available to those persons that provides a legible image of the maintenance information and instructions, or a system that is able to retrieve the maintenance information and instructions in the English language. (h) If a program manager conducts aircraft...
20 CFR 401.150 - Compatible purposes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Employees' Benefits SOCIAL SECURITY ADMINISTRATION PRIVACY AND DISCLOSURE OF OFFICIAL RECORDS AND... Privacy Act allows us to disclose information maintained in a system of records without your consent to any other party if such disclosure is pursuant to a routine use published in the system's notice of...
Ebrahiminia, Vahid; Yasini, Mobin; Lamy, Jean Baptiste
2013-01-01
Lack of interoperability between health information systems is a major obstacle in implementing Clinical decision supports systems (CDSS) and their widespread disseminations. Virtual Medical Record (vMR) proposed by HL7 is a common data model for representing clinical information Inputs and outputs that can be used by CDSS and local clinical systems. A CDSS called ASTI used a similar model to represent clinical data and therapeutic history of patient. In order to evaluate the compatibility of ASTI with vMR, we started to map the ASTI model of representing patient’s therapeutic data to vMR. We compared the data elements and associated terminologies used in ASTI and vMR and we evaluated the semantic fidelity between the models. Only one data element the qualitative description of drug dosage, did not match the vMR model. However, it can be calculated in the execution engine. The semantic fidelity was satisfactorily preserved in 12 of 17 elements mapped between the models. This model of ASTI seems compatible to vMR. Further work is necessary to evaluate the compatibility of clinical data model of ASTI to vMR and the use of vMR in implementing practice guidelines. PMID:24551344
Empirical study of fuzzy compatibility measures and aggregation operators
NASA Astrophysics Data System (ADS)
Cross, Valerie V.; Sudkamp, Thomas A.
1992-02-01
Two fundamental requirements for the generation of support using incomplete and imprecise information are the ability to measure the compatibility of discriminatory information with domain knowledge and the ability to fuse information obtained from disparate sources. A generic architecture utilizing the generalized fuzzy relational database model has been developed to empirically investigate the support generation capabilities of various compatibility measures and aggregation operators. This paper examines the effectiveness of combinations of compatibility measures from the set-theoretic, geometric distance, and logic- based classes paired with t-norm and generalized mean families of aggregation operators.
Geographic Information Systems and Martian Data: Compatibility and Analysis
NASA Technical Reports Server (NTRS)
Jones, Jennifer L.
2005-01-01
Planning future landed Mars missions depends on accurate, informed data. This research has created and used spatially referenced instrument data from NASA missions such as the Thermal Emission Imaging System (THEMIS) on the Mars Odyssey Orbiter and the Mars Orbital Camera (MOC) on the Mars Global Surveyor (MGS) Orbiter. Creating spatially referenced data enables its use in Geographic Information Systems (GIS) such as ArcGIS. It has then been possible to integrate this spatially referenced data with global base maps and build and populate location based databases that are easy to access.
The CD-ROM Services of SilverPlatter Information, Inc.
ERIC Educational Resources Information Center
Allen, Robert J.
1985-01-01
The SilverPlatter system is a complete, stand-alone system, consisting of an IBM (or compatible) personal computer, compact disc with read-only memory (CD-ROM) drive, software, and one or more databases. Large databases (e.g., ERIC, PsycLIT) will soon be available on the system for "local" installation in schools, libraries, and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
Pulse Code Modulation (PCM) encoder handbook for Aydin Vector MMP-600 series system
NASA Technical Reports Server (NTRS)
Currier, S. F.; Powell, W. R.
1986-01-01
The hardware and software characteristics of a time division multiplex system are described. The system is used to sample analog and digital data. The data is merged with synchronization information to produce a serial pulse coded modulation (PCM) bit stream. Information presented herein is required by users to design compatible interfaces and assure effective utilization of this encoder system. GSFC/Wallops Flight Facility has flown approximately 50 of these systems through 1984 on sounding rockets with no inflight failures. Aydin Vector manufactures all of the components for these systems.
Hierarchical clustering method for improved prostate cancer imaging in diffuse optical tomography
NASA Astrophysics Data System (ADS)
Kavuri, Venkaiah C.; Liu, Hanli
2013-03-01
We investigate the feasibility of trans-rectal near infrared (NIR) based diffuse optical tomography (DOT) for early detection of prostate cancer using a transrectal ultrasound (TRUS) compatible imaging probe. For this purpose, we designed a TRUS-compatible, NIR-based image system (780nm), in which the photo diodes were placed on the trans-rectal probe. DC signals were recorded and used for estimating the absorption coefficient. We validated the system using laboratory phantoms. For further improvement, we also developed a hierarchical clustering method (HCM) to improve the accuracy of image reconstruction with limited prior information. We demonstrated the method using computer simulations laboratory phantom experiments.
A Course in Information Techniques for Dental Students
Dannenberg, Dena
1972-01-01
A course plan is presented for introducing literature searching and critical skills to dental students. Topics include the “life cycle of information,” reference sources available, search procedure, abstracting and indexing, and personal information systems. Teaching is structured around planned seminars and student projects. The course design is compatible with traditional dental curricula and is based on students' interest in dentistry rather than in information/library science. PMID:5024320
ERIC Educational Resources Information Center
Pereira, Audrey Smith; Wahi, Monika Maya
2017-01-01
Although course management systems (CMSs) provide technology platforms that help faculty members adopt better techniques for teaching and learning, and training contributes to faculty information technology (IT) use, many higher education faculty members do not complete CMS training programs, resulting in underuse of CMSs. Therefore, the overall…
Ready Set. . .Authoring Systems to Get You Started on Interactive Video Design.
ERIC Educational Resources Information Center
Rhodes, Dent M.; Azbell, Janet White
1986-01-01
Evaluates four authoring systems used to develop computer aided interactive video: The Instructor, InfoWriter, IDeAS, and ProCAL2. The information provided includes hardware requirements, compatibility with videotape and/or videodisc, instructional options available, user data-management capabilities, procedures for logging tapes, and access for…
Mai, Lan-Yin; Li, Yi-Xuan; Chen, Yong; Xie, Zhen; Li, Jie; Zhong, Ming-Yu
2014-05-01
The compatibility of traditional Chinese medicines (TCMs) formulae containing enormous information, is a complex component system. Applications of mathematical statistics methods on the compatibility researches of traditional Chinese medicines formulae have great significance for promoting the modernization of traditional Chinese medicines and improving clinical efficacies and optimizations of formulae. As a tool for quantitative analysis, data inference and exploring inherent rules of substances, the mathematical statistics method can be used to reveal the working mechanisms of the compatibility of traditional Chinese medicines formulae in qualitatively and quantitatively. By reviewing studies based on the applications of mathematical statistics methods, this paper were summarized from perspective of dosages optimization, efficacies and changes of chemical components as well as the rules of incompatibility and contraindication of formulae, will provide the references for further studying and revealing the working mechanisms and the connotations of traditional Chinese medicines.
Remote sensing, land use, and demography - A look at people through their effects on the land
NASA Technical Reports Server (NTRS)
Paul, C. K.; Landini, A. J.
1976-01-01
Relevant causes of failure by the remote sensing community in the urban scene are analyzed. The reasons for the insignificant role of remote sensing in urban land use data collection are called the law of realism, the incompatibility of remote sensing and urban management system data formats is termed the law of nominal/ordinal systems compatibility, and the land use/population correlation dilemma is referred to as the law of missing persons. The study summarizes the three laws of urban land use information for which violations, avoidance, or ignorance have caused the decline of present remote sensing research. Particular attention is given to the rationale for urban land use information and for remote sensing. It is shown that remote sensing of urban land uses compatible with the three laws can be effectively developed by realizing the 10 percent contribution of remote sensing to urban land use planning data collection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1996-07-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1996-11-15
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.
1990-12-01
data rate to the electronics would be much lower on the average and the data much "richer" in information. Intelligent use of...system bottleneck, a high data rate should be provided by I/O systems. 2. machines with intelligent storage management specially designed for logic...management information processing, surveillance sensors, intelligence data collection and handling, solid state sciences, electromagnetics, and propagation, and electronic reliability/maintainability and compatibility.
Obsessive-compulsive tendencies are associated with a focused information processing strategy.
Soref, Assaf; Dar, Reuven; Argov, Galit; Meiran, Nachshon
2008-12-01
The study examined the hypothesis that obsessive-compulsive (OC) tendencies are related to a reliance on focused and serial rather than a parallel, speed-oriented information processing style. Ten students with high OC tendencies and 10 students with low OC tendencies performed the flanker task, in which they were required to quickly classify a briefly presented target letter (S or H) that was flanked by compatible (e.g., SSSSS) or incompatible (e.g., HHSHH) noise letters. Participants received 4 blocks of 100 trials each, two with 50% compatible trials and two with 80% compatible trials and were informed of the probability of compatible trials before the beginning of each block. As predicted, high OC participants, as compared to low OC participants, had slower overall reaction time (RT) and lower tendency for parallel processing (defined as incompatible trials RT minus compatible trials RT). Low, more than high OC participants tended to adjust their focused/parallel processing including a shift towards parallel processing in blocks with 80% compatible trials and in trials following compatible trials. Implications of these results to the cognitive theory and therapy of OCD are discussed.
Human factors aspects of control room design
NASA Technical Reports Server (NTRS)
Jenkins, J. P.
1983-01-01
A plan for the design and analysis of a multistation control room is reviewed. It is found that acceptance of the computer based information system by the uses in the control room is mandatory for mission and system success. Criteria to improve computer/user interface include: match of system input/output with user; reliability, compatibility and maintainability; easy to learn and little training needed; self descriptive system; system under user control; transparent language, format and organization; corresponds to user expectations; adaptable to user experience level; fault tolerant; dialog capability user communications needs reflected in flexibility, complexity, power and information load; integrated system; and documentation.
Liu, Yung-Ching; Jhuang, Jing-Wun
2012-07-01
A driving simulator study was conducted to evaluate the effects of five in-vehicle warning information displays upon drivers' emergent response and decision performance. These displays include visual display, auditory displays with and without spatial compatibility, hybrid displays in both visual and auditory format with and without spatial compatibility. Thirty volunteer drivers were recruited to perform various tasks that involved driving, stimulus-response, divided attention and stress rating. Results show that for displays of single-modality, drivers benefited more when coping with visual display of warning information than auditory display with or without spatial compatibility. However, auditory display with spatial compatibility significantly improved drivers' performance in reacting to the divided attention task and making accurate S-R task decision. Drivers' best performance results were obtained for hybrid display with spatial compatibility. Hybrid displays enabled drivers to respond the fastest and achieve the best accuracy in both S-R and divided attention tasks. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Herbal compatibility of traditional Chinese medical formulas for acquired immunodeficiency syndrome.
Cui, Meng; Li, Jinghua; Li, Haiyan; Song, Chunxin
2012-09-01
Because herbal compatibility is one of the most important reasons why Traditional Chinese Medcine (TCM) formulas are effective for acquired immunodeficiency syndrome (AIDS), our study aimed to determine the compatibility of herbs based on published AIDS clinical research in Chinese periodicals. To achieve this aim, we designed a new data-mining algorithm according to TCM data characteristics. We found 25 clinical AIDS studies, all using Chinese herbs for treatment, in the Traditional Chinese Medicine Database System, and information on diagnosis and treatment was extracted. To find out herbal compatibility, especially the formulae for herbal combinations, we proposed an improved association rule algorithm based on the frequency of combinations. In this algorithm, all the compatibility relationships were displayed in a tree structure, by which the relationship between formulas and their derivation could be clearly inferred. Data analysis showed that approximately 100 herbs have been used for treating AIDS. Based on the whole herb compatibility tree, we calculated a basic formula for AIDS: Huang Qi combined with Ren Shen, Fu Ling, Bai Zhu, Bai Zhu, Dang Gui, and Bai Shao. This formula, deriving from most of clinical prescriptions, and was chosed by most of clinicians for AIDS treatment. From data mining we found that Qi replenishment and detoxification were the main treatment principles, which coincided with the AIDS pathological mechanism in which immune function is destroyed by human immunodeficiency virus (HIV). Our data-mining results suggest that the core TCM treatment of AIDS is replenishing Qi and detoxification, by which AIDS patients' immune system may be enhanced. Compatibility of Huang Qi with some frequently-used herbs have shown real efficacy in clinical practice, which warrants pharmacological research in the future.
Surveillance of industrial processes with correlated parameters
White, Andrew M.; Gross, Kenny C.; Kubic, William L.; Wigeland, Roald A.
1996-01-01
A system and method for surveillance of an industrial process. The system and method includes a plurality of sensors monitoring industrial process parameters, devices to convert the sensed data to computer compatible information and a computer which executes computer software directed to analyzing the sensor data to discern statistically reliable alarm conditions. The computer software is executed to remove serial correlation information and then calculate Mahalanobis distribution data to carry out a probability ratio test to determine alarm conditions.
Multi-imager compatible actuation principles in surgical robotics.
Stoianovici, D
2005-01-01
Today's most successful surgical robots are perhaps surgeon-driven systems, such as the daVinci (Intuitive Surgical Inc., USA, www.intuitivesurgical.com). These have already enabled surgery that was unattainable with classic instrumentation; however, at their present level of development, they have limited utility. The drawback of these systems is that they are independent self-contained units, and as such, they do not directly take advantage of patient data. The potential of these new surgical tools lies much further ahead. Integration with medical imaging and information are needed for these devices to achieve their true potential. Surgical robots and especially their subclass of image-guided systems require special design, construction and control compared to industrial types, due to the special requirements of the medical and imaging environments. Imager compatibility raises significant engineering challenges for the development of robotic manipulators with respect to imager access, safety, ergonomics, and above all the non-interference with the functionality of the imager. These apply to all known medical imaging types, but are especially challenging for achieving compatibility with the class of MRI systems. Even though a large majority of robotic components may be redesigned to be constructed of MRI compatible materials, for other components such as the motors used in actuation, prescribing MRI compatible materials alone is not sufficient. The electromagnetic motors most commonly used in robotic actuation, for example, are incompatible by principle. As such, alternate actuation principles using "intervention friendly" energy should be adopted and/or devised for these special surgical and radiological interventions. This paper defines the new concept of Multi-Imager Compatibility of surgical manipulators and describes its requirements. Subsequently, the paper gives several recommendations and proposes new actuation principles for this concept. Several implementations have been constructed and tested, and the results are presented here. This is the first paper addressing these issues. Copyright 2005 Robotic Publications Ltd.
An Evaluation of Alternative Delivery Modes for Information Services.
ERIC Educational Resources Information Center
Short, Craig; Christal, Melodie E.
The use of the floppy disk as an alternative mode for delivering Information Services reports was evaluated for fiscal year 1985 by the National Center for Higher Education Management Systems (NCHEMS). A 5.25 inch, 8/9 sector, 40 track ASCII floppy disk used under PC-DOS on the IBM PC and IBM PC compatible hardware was tested. Tabular data but not…
Online thesis guidance management information system
NASA Astrophysics Data System (ADS)
Nasution, T. H.; Pratama, F.; Tanjung, K.; Siregar, I.; Amalia, A.
2018-03-01
The development of internet technology in education is still not maximized, especially in the process of thesis guidance between students and lecturers. Difficulties met the lecturers to help students during thesis guidance is the limited communication time and the compatibility of schedule between students and lecturer. To solve this problem, we designed an online thesis guidance management information system that helps students and lecturers to do thesis tutoring process anytime, anywhere. The system consists of a web-based admin app for usage management and an android-based app for students and lecturers.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-12
... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Airport Noise... respondents are those airport operators voluntarily submitting noise exposure maps and noise compatibility....gov . SUPPLEMENTARY INFORMATION: OMB Control Number: 2120-0517. Title: Airport Noise Compatibility...
Problems in the long-term storage of data obtained from scientific space experiments
NASA Technical Reports Server (NTRS)
Zlotin, G. N.; Khovanskiy, Y. D.
1975-01-01
It is shown that long-term data storage systems can be achieved when the system which organizes and conducts the scientific space experiments is equipped with a specialized subsystem: the information filing system. Its main functions are described along with the necessity of stage-by-stage development and compatibility with the data processing systems. The requirements for long-term data storage media are discussed.
30 CFR 1227.103 - What must a State's delegation proposal contain?
Code of Federal Regulations, 2013 CFR
2013-07-01
... processing, including compatibility with ONRR automated systems, electronic commerce capabilities, and data storage capabilities; (B) Accessing reference data; (C) Contacting production or royalty reporters; (D...) Maintaining security of confidential and proprietary information; and (H) Providing data to other Federal...
30 CFR 1227.103 - What must a State's delegation proposal contain?
Code of Federal Regulations, 2014 CFR
2014-07-01
... processing, including compatibility with ONRR automated systems, electronic commerce capabilities, and data storage capabilities; (B) Accessing reference data; (C) Contacting production or royalty reporters; (D...) Maintaining security of confidential and proprietary information; and (H) Providing data to other Federal...
30 CFR 1227.103 - What must a State's delegation proposal contain?
Code of Federal Regulations, 2012 CFR
2012-07-01
... processing, including compatibility with ONRR automated systems, electronic commerce capabilities, and data storage capabilities; (B) Accessing reference data; (C) Contacting production or royalty reporters; (D...) Maintaining security of confidential and proprietary information; and (H) Providing data to other Federal...
Surveillance of industrial processes with correlated parameters
White, A.M.; Gross, K.C.; Kubic, W.L.; Wigeland, R.A.
1996-12-17
A system and method for surveillance of an industrial process are disclosed. The system and method includes a plurality of sensors monitoring industrial process parameters, devices to convert the sensed data to computer compatible information and a computer which executes computer software directed to analyzing the sensor data to discern statistically reliable alarm conditions. The computer software is executed to remove serial correlation information and then calculate Mahalanobis distribution data to carry out a probability ratio test to determine alarm conditions. 10 figs.
Theodoridis, Michael P; Mollov, Stefan V
2014-10-01
This article presents the design of a domestic, radiofrequency induction charger for implants toward compliance with the Federal Communications Commission safety and electromagnetic compatibility regulations. The suggested arrangement does not impose any patient compliance requirements other than the use of a designated bed for night sleep, and therefore can find a domestic use. The method can be applied to a number of applications; a rechargeable pacemaker is considered as a case study. The presented work has proven that it is possible to realize a fully compliant inductive charging system with minimal patient interaction, and has generated important information for consideration by the designers of inductive charging systems. Experimental results have verified the validity of the theoretical findings.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-21
.... The FAA collects information from airport sponsors and planning agencies in order to administer the...-272), which is referred to as the ``Act,'' provides funding for airport planning and development... funds for noise compatibility planning and to carry out noise compatibility programs. The information...
Unification - An international aerospace information issue
NASA Technical Reports Server (NTRS)
Cotter, Gladys A.; Lahr, Thomas F.
1992-01-01
Scientific and Technical Information (STI) represents the results of large investments in research and development (R&D) and the expertise of a nation and is a valuable resource. For more than four decades, NASA and its predecessor organizations have developed and managed the preeminent aerospace information system. NASA obtains foreign materials through its international exchange relationships, continually increasing the comprehensiveness of the NASA Aerospace Database (NAD). The NAD is de facto the international aerospace database. This paper reviews current NASA goals and activities with a view toward maintaining compatibility among international aerospace information systems, eliminating duplication of effort, and sharing resources through international cooperation wherever possible.
Initial Experience With A Prototype Storage System At The University Of North Carolina
NASA Astrophysics Data System (ADS)
Creasy, J. L.; Loendorf, D. D.; Hemminger, B. M.
1986-06-01
A prototype archiving system manufactured by the 3M Corporation has been in place at the University of North Carolina for approximately 12 months. The system was installed as a result of a collaboration between 3M and UNC, with 3M seeking testing of their system, and UNC realizing the need for an archiving system as an essential part of their PACS test-bed facilities. System hardware includes appropriate network and disk interface devices as well as media for both short and long term storage of images and their associated information. The system software includes those procedures necessary to communicate with the network interface elements(NIEs) as well as those procedures necessary to interpret the ACR-NEMA header blocks and to store the images. A subset of the total ACR-NEMA header is parsed and stored in a relational database system. The entire header is stored on disk with the completed study. Interactive programs have been developed that allow radiologists to easily retrieve information about the archived images and to send the full images to a viewing console. Initial experience with the system has consisted primarily of hardware and software debugging. Although the system is ACR-NEMA compatable, further objective and subjective assessments of system performance is awaiting the connection of compatable consoles and acquisition devices to the network.
NASA Technical Reports Server (NTRS)
Karen, P.; Fjellvag, H.; Kjekshus, A.
1990-01-01
Electrical transport properties of the oxidic high T(sub c) superconductors are significantly affected by the presence of minor amounts of various elements adventing as impurities, e.g., from the chemical environment during manufacturing. YBa2Cu3O(9-delta) is prone to an extinction of the superconductivity on (partial) substitution of all four elemental components. E.g., Pr (for Y), La (for Ba), Zn (for Cu) or peroxygroup (for O) substituents will alter some of the superconductivity preconditions, like mixed valence state in Cu3O7/O(9-delta) network or structural distortion of the network. Although various pseudoternary chemical equilibrium phase diagrams of the Y(O)-Ba(O)-Cu(O) system now are available, no consensus is generally shown, however, this is partly due to lack of compatible definitions of the equilibrium conditions. Less information is available about the phase compatibilities in the appropriate quaternary phase diagram (including oxygen) and virtually no information exists about any pentenary phase diagrams (including one impurity). Unfortunately, complexity of such systems, stemming both from number of quaternary or pentenary compounds and from visualizing the five-component phase system, limits this presentation to more or less close surroundings of the YBa2Cu3O(9-delta) type phase in appropriate pseudoquaternary or pseudopseudoternary diagrams, involving Y-Ba-Cu and O, O-CO2, alkaline metals, Mg and alkaline earths, and Sc and most of the 3-d and 4-f elements. The systems were investigated by means of x ray diffraction, neutron diffraction and chemical analytical methods on samples prepared by sol-gel technique from citrates. The superconductivity was characterized by measuring the diamagnetic susceptibility by SQUID.
Management Sciences Division Annual Report (10th)
1993-01-01
of the Weapon System Management Information System (WSMIS). TheI Aircraft Sustainability Model ( ASM ) is the computational technique employed by...provisioning. We enhanced the capabilities of RBIRD by using the Aircraft Sustainability Model ( ASM ) for the spares calculation. ASM offers many... ASM for several years to 3 compute spares for war. It is also fully compatible with the Air Force’s peacetime spares computation system (D041). This
Reasoning with Incomplete and Uncertain Information
1991-08-01
are rationally compatible (just as is the case in the fundamental computational mechanisms of truth maintenance systems ). The logics we construct will...complete, pre- cise, and unvarying. This fundamental assumption is a principal source of the limitation of many diagnostic systems to single fault diagnoses...Air Force Systems Command Griffiss Air Force Base, NY 13441-5700 This report has been reviewed by the Rome Laboratory Public Affairs Dffice (PA) and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1997-02-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.« less
NASA Astrophysics Data System (ADS)
Yu, Weishui; Luo, Changshou; Zheng, Yaming; Wei, Qingfeng; Cao, Chengzhong
2017-09-01
To deal with the “last kilometer” problem during the agricultural science and technology information service, we analyzed the feasibility, necessity and advantages of WebApp applied to agricultural information service and discussed the modes of WebApp used in agricultural information service based on the requirements analysis and the function of WebApp. To overcome the existing App’s defects of difficult installation and weak compatibility between the mobile operating systems, the Beijing Agricultural Sci-tech Service Hotline WebApp was developed based on the HTML and JAVA technology. The WebApp has greater compatibility and simpler operation than the Native App, what’s more, it can be linked to the WeChat public platform making it spread easily and run directly without setup process. The WebApp was used to provide agricultural expert consulting services and agriculture information push, obtained a good preliminary application achievement. Finally, we concluded the creative application of WebApp in agricultural consulting services and prospected the development of WebApp in agricultural information service.
AQUIS: A PC-based source information manager
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, A.E.; Huber, C.C.; Tschanz, J.
1993-05-01
The Air Quality Utility Information System (AQUIS) was developed to calculate emissions and track them along with related information about sources, stacks, controls, and permits. The system runs on IBM- compatible personal computers with dBASE IV and tracks more than 1, 200 data items distributed among various source categories. AQUIS is currently operating at 11 US Air Force facilities, which have up to 1, 000 sources, and two headquarters. The system provides a flexible reporting capability that permits users who are unfamiliar with database structure to design and prepare reports containing user- specified information. In addition to the criteria pollutants,more » AQUIS calculates compound-specific emissions and allows users to enter their own emission estimates.« less
AQUIS: A PC-based source information manager
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, A.E.; Huber, C.C.; Tschanz, J.
1993-01-01
The Air Quality Utility Information System (AQUIS) was developed to calculate emissions and track them along with related information about sources, stacks, controls, and permits. The system runs on IBM- compatible personal computers with dBASE IV and tracks more than 1, 200 data items distributed among various source categories. AQUIS is currently operating at 11 US Air Force facilities, which have up to 1, 000 sources, and two headquarters. The system provides a flexible reporting capability that permits users who are unfamiliar with database structure to design and prepare reports containing user- specified information. In addition to the criteria pollutants,more » AQUIS calculates compound-specific emissions and allows users to enter their own emission estimates.« less
40 CFR 70.8 - Permit review by EPA and affected States.
Code of Federal Regulations, 2013 CFR
2013-07-01
... compatible with EPA's national database management system. (2) The Administrator may waive the requirements...) Transmission of information to the Administrator. (1) The permit program shall require that the permitting authority provide to the Administrator a copy of each permit application (including any application for...
40 CFR 70.8 - Permit review by EPA and affected States.
Code of Federal Regulations, 2014 CFR
2014-07-01
... compatible with EPA's national database management system. (2) The Administrator may waive the requirements...) Transmission of information to the Administrator. (1) The permit program shall require that the permitting authority provide to the Administrator a copy of each permit application (including any application for...
40 CFR 70.8 - Permit review by EPA and affected States.
Code of Federal Regulations, 2010 CFR
2010-07-01
... compatible with EPA's national database management system. (2) The Administrator may waive the requirements...) Transmission of information to the Administrator. (1) The permit program shall require that the permitting authority provide to the Administrator a copy of each permit application (including any application for...
40 CFR 70.8 - Permit review by EPA and affected States.
Code of Federal Regulations, 2011 CFR
2011-07-01
... compatible with EPA's national database management system. (2) The Administrator may waive the requirements...) Transmission of information to the Administrator. (1) The permit program shall require that the permitting authority provide to the Administrator a copy of each permit application (including any application for...
40 CFR 70.8 - Permit review by EPA and affected States.
Code of Federal Regulations, 2012 CFR
2012-07-01
... compatible with EPA's national database management system. (2) The Administrator may waive the requirements...) Transmission of information to the Administrator. (1) The permit program shall require that the permitting authority provide to the Administrator a copy of each permit application (including any application for...
Analysis research for earth resource information systems - Where do we stand
NASA Technical Reports Server (NTRS)
Landgrebe, D. A.
1974-01-01
Discussion of the state of the technology of earth resources information systems relative to future operational implementation. The importance of recognizing the difference between systems with image orientation and systems with numerical orientation is illustrated in an example concerning the effect of noise on multiband multispectral data obtained in an agricultural experiment. It is suggested that the data system hardware portion of the total earth resources information system be designed in terms of a numerical orientation; it is argued, however, that this choise is entirely compatible with image-oriented analysis tasks. Some aspects of interfacing such an advanced technology with an operational user community in such a way as to accommodate the user's need for flexibility and yet provide the services needed on a cost-effective basis are discussed.
AQUIS: A PC-based air inventory and permit manager
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, A.E.; Huber, C.C.; Tschanz, J.
1992-01-01
The Air Quality Utility Information System (AQUIS) was developed to calculate and track sources, emissions, stacks, permits, and related information. The system runs on IBM-compatible personal computers with dBASE IV and tracks more than 1,200 data items distributed among various source categories. AQUIS is currently operating at nine US Air Force facilities that have up to 1,000 sources. The system provides a flexible reporting capability that permits users who are unfamiliar with database structure to design and prepare reports containing user-specified information. In addition to six criteria pollutants, AQUIS calculates compound-specific emissions and allows users to enter their own emissionmore » estimates.« less
Extreme environments select for reproductive assurance: evidence from evening primroses (Oenothera).
Evans, Margaret E K; Hearn, David J; Theiss, Kathryn E; Cranston, Karen; Holsinger, Kent E; Donoghue, Michael J
2011-07-01
Competing evolutionary forces shape plant breeding systems (e.g. inbreeding depression, reproductive assurance). Which of these forces prevails in a given population or species is predicted to depend upon such factors as life history, ecological conditions, and geographical context. Here, we examined two such predictions: that self-compatibility should be associated with the annual life history or extreme climatic conditions. We analyzed data from a clade of plants remarkable for variation in breeding system, life history and climatic conditions (Oenothera, sections Anogra and Kleinia, Onagraceae). We used a phylogenetic comparative approach and Bayesian or hybrid Bayesian tests to account for phylogenetic uncertainty. Geographic information system (GIS)-based climate data and ecological niche modeling allowed us to quantify climatic conditions. Breeding system and reproductive life span are not correlated in Anogra and Kleinia. Instead, self-compatibility is associated with the extremes of temperature in the coldest part of the year and precipitation in the driest part of the year. In the 60 yr since this pattern was anticipated, this is the first demonstration of a relationship between the evolution of self-compatibility and climatic extremes. We discuss possible explanations for this pattern and possible implications with respect to anthropogenic climate change. © 2011 The Authors. New Phytologist © 2011 New Phytologist Trust.
Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.
Yu, Ningbo; Gassert, Roger; Riener, Robert
2011-07-01
Robotic and mechatronic devices that work compatibly with magnetic resonance imaging (MRI) are applied in diagnostic MRI, image-guided surgery, neurorehabilitation and neuroscience. MRI-compatible mechatronic systems must address the challenges imposed by the scanner's electromagnetic fields. We have developed objective quantitative evaluation criteria for device characteristics needed to formulate design guidelines that ensure MRI-compatibility based on safety, device functionality and image quality. The mutual interferences between an MRI system and mechatronic devices working in its vicinity are modeled and tested. For each interference, the involved components are listed, and a numerical measure for "MRI-compatibility" is proposed. These interferences are categorized into an MRI-compatibility matrix, with each element representing possible interactions between one part of the mechatronic system and one component of the electromagnetic fields. Based on this formulation, design principles for MRI-compatible mechatronic systems are proposed. Furthermore, test methods are developed to examine whether a mechatronic device indeed works without interferences within an MRI system. Finally, the proposed MRI-compatibility criteria and design guidelines have been applied to an actual design process that has been validated by the test procedures. Objective and quantitative MRI-compatibility measures for mechatronic and robotic devices have been established. Applying the proposed design principles, potential problems in safety, device functionality and image quality can be considered in the design phase to ensure that the mechatronic system will fulfill the MRI-compatibility criteria. New guidelines and test procedures for MRI instrument compatibility provide a rational basis for design and evaluation of mechatronic devices in various MRI applications. Designers can apply these criteria and use the tests, so that MRI-compatibility results can accrue to build an experiential database.
48 CFR 3452.239-73 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Configuration (FDCC) Compatibility (MAR 2011) (a) (1) The provider of information technology shall certify... alter the configuration settings from the approved FDCC configuration. The information technology should... DEPARTMENT OF EDUCATION ACQUISITION REGULATION CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...
48 CFR 3452.239-73 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Configuration (FDCC) Compatibility (MAR 2011) (a) (1) The provider of information technology shall certify... alter the configuration settings from the approved FDCC configuration. The information technology should... DEPARTMENT OF EDUCATION ACQUISITION REGULATION CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...
48 CFR 3452.239-73 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Configuration (FDCC) Compatibility (MAR 2011) (a) (1) The provider of information technology shall certify... alter the configuration settings from the approved FDCC configuration. The information technology should... DEPARTMENT OF EDUCATION ACQUISITION REGULATION CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...
48 CFR 3452.239-73 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Configuration (FDCC) Compatibility (MAR 2011) (a) (1) The provider of information technology shall certify... alter the configuration settings from the approved FDCC configuration. The information technology should... DEPARTMENT OF EDUCATION ACQUISITION REGULATION CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...
ERIC Educational Resources Information Center
Building Systems Information Clearinghouse, Menlo Park, CA.
To qualify for inclusion in this listing, a building must have been constructed with two or more compatible building subsystems, one of which is structure. It is estimated that at least 400 schools that satisfy this definition have been constructed in the U. S. and Canada, about one quarter of which appear in this listing. Beginning with this…
A Low Cost TDRSS Compatible Transmitter Option
NASA Technical Reports Server (NTRS)
Whiteman, Don
2005-01-01
The NASA Space-based Telemetry and Range Safety (STARS) program has developed and tested a low cost Ku-Band transmitter alternative for TDRSS applications based on an existing IRIG shaped offset quaternary phase shift keying (SOQPSK) transmitter. This paper presents information related to the implementation of this low cost system, as well as performance measurements of the alternative TDRSS transmitter system compared with an existing QPSK TDRSS transmitter.
NASA Technical Reports Server (NTRS)
1980-01-01
The compatibility of the Multimission Modular Spacecraft (MMS) Ground Support Software System (GSSS), currently operational on a ModComp IV/35, with the VAX 11/780 system is discussed. The compatibility is examined in various key areas of the GSSS through the results of in depth testing performed on the VAX 11/780 and ModComp IV/35 systems. The compatibility of the GSSS with the ModComp CLASSIC is presented based upon projections from ModComp supplied literature.
Hospital information management system: an evolutionary knowledge management perspective.
Wadhwa, S; Saxena, Avneet; Wadhwa, Bharat
2007-01-01
The evolving paradigm shift resulting from IT, social and technological changes has created a need for developing an innovative knowledge-based healthcare system, which can effectively meet global healthcare system demands and also cater to future trends. The Hospital Information Management System (HIMS) is developed with this sole aim in mind, which helps in processing and management of hospital information not only inside the boundary, but also beyond the hospital boundary, e.g., telemedicine or e-healthcare. The purpose of this paper is to present such kind of functional HIMS, which can efficiently satisfy the current and future system requirements by using Knowledge Management (KM) and data management systems. The HIMS is developed in a KM context, wherein users can share and use the knowledge more effectively. The proposed system is fully compatible with future technical, social, managerial and economical requirements.
Performance interface document for the S-band diplexer for space users of NASA networks
NASA Technical Reports Server (NTRS)
Line, L. G.
1985-01-01
This report discusses the test results and interfacing information of the S-band diplexer development program supported by RTOP 310 funding. The program was implemented to reduce the S-band transponder noise figure by minimizing the receive channel insertion loss and to also provide Space Transportation System (STS) compatibility by providing 70-db rejection up to 16 GHz in the receive channel. This compatibility includes rejection of signals from the Shuttle S-band Data Link, the K-band Data Link, and the K-band Rendezvous Radar. The first of many projects to benefit from this accomplishment was the Earth Radiation Budget Satellite (ERBS).
47 CFR 68.415 - Hearing aid-compatibility and volume control informal complaints.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Hearing aid-compatibility and volume control informal complaints. 68.415 Section 68.415 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK Complaint...
47 CFR 68.415 - Hearing aid-compatibility and volume control informal complaints.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Hearing aid-compatibility and volume control informal complaints. 68.415 Section 68.415 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK Complaint...
Mohd Salleh, Mohd Idzwan; Zakaria, Nasriah; Abdullah, Rosni
The Ministry of Health Malaysia initiated the total hospital information system (THIS) as the first national electronic health record system for use in selected public hospitals across the country. Since its implementation 15 years ago, there has been the critical requirement for a systematic evaluation to assess its effectiveness in coping with the current system, task complexity, and rapid technological changes. The study aims to assess system quality factors to predict the performance of electronic health in a single public hospital in Malaysia. Non-probability sampling was employed for data collection among selected providers in a single hospital for two months. Data cleaning and bias checking were performed before final analysis in partial least squares-structural equation modeling. Convergent and discriminant validity assessments were satisfied the required criterions in the reflective measurement model. The structural model output revealed that the proposed adequate infrastructure, system interoperability, security control, and system compatibility were the significant predictors, where system compatibility became the most critical characteristic to influence an individual health care provider's performance. The previous DeLone and McLean information system success models should be extended to incorporate these technological factors in the medical system research domain to examine the effectiveness of modern electronic health record systems. In this study, care providers' performance was expected when the system usage fits with patients' needs that eventually increased their productivity. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
Compatibility: drugs and parenteral nutrition
Miranda, Talita Muniz Maloni; Ferraresi, Andressa de Abreu
2016-01-01
ABSTRACT Objective Standardization and systematization of data to provide quick access to compatibility of leading injectable drugs used in hospitals for parenteral nutrition. Methods We selected 55 injectable drugs analyzed individually with two types of parenteral nutrition: 2-in-1 and 3-in-1. The following variables were considered: active ingredient, compatibility of drugs with the parenteral nutrition with or without lipids, and maximum drug concentration after dilution for the drugs compatible with parenteral nutrition. Drugs were classified as compatible, incompatible and untested. Results After analysis, relevant information to the product’s compatibility with parental nutrition was summarized in a table. Conclusion Systematization of compatibility data provided quick and easy access, and enabled standardizing pharmacists work. PMID:27074235
48 CFR 1552.215-72 - Instructions for the Preparation of Proposals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of the information, to expedite review of the proposal, submit an IBM-compatible software or storage... offeror used another spreadsheet program, indicate the software program used to create this information... submission of a compatible software or device will expedite review, failure to submit a disk will not affect...
48 CFR 1552.215-72 - Instructions for the Preparation of Proposals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of the information, to expedite review of the proposal, submit an IBM-compatible software or storage... offeror used another spreadsheet program, indicate the software program used to create this information... submission of a compatible software or device will expedite review, failure to submit a disk will not affect...
Compatibility Problems of Network Interfacing.
ERIC Educational Resources Information Center
Stevens, Mary Elizabeth
From the standpoint of information network technology there is a necessary emphasis upon compatibility requirements which, in turn, will be met at least in part by various techniques of achieving convertibility --- between machine and machine, between man and machine, and between man and man. It may be hoped that improved compatibilities between…
77 FR 14461 - Approval of Noise Compatibility Program for W.K. Airport, Battle Creek, MI
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-09
... Program for W.K. Airport, Battle Creek, MI AGENCY: Federal Aviation Administration, DOT. ACTION: Notice....K. Kellogg Airport noise compatibility program. All of the recommendations of the program were... Noise Compatibility Program for W.K. Kellogg Airport is February 16, 2012. FOR FURTHER INFORMATION...
The Area Resource File: ARF. A Manpower Planning and Research Tool.
ERIC Educational Resources Information Center
Applied Management Sciences, Inc., Silver Spring, MD.
This publication describes the Area Resource File (ARF), a computer-based, county-specific health information system with broad analytical capabilities which utilizes manpower and manpower-related data that are available on a compatible basis for all counties in the United States, and which was developed to summarize statistics from many disparate…
An IBM Compatible Participant Data Base System for Outdoor Programs.
ERIC Educational Resources Information Center
Watters, Ron
The process of maintaining mailing lists and other informational files on outdoor program participants is, plainly and simply, a pain in the neck. Mailing list maintenance is particularly difficult for programs that deal with university students, due to their frequent moves. This paper describes a new software program, the Outdoor Program Data…
Clinical Information System Post-Adoption Evaluation at the Georges Pompidou University Hospital
Palm, Jean-Marc; Dart, Thierry; Dupuis, Isabelle; Leneveut, Laurence; Degoulet, Patrice
2010-01-01
The evaluation of a clinical information system (CIS) at different stages of deployment and routine use is a key factor to improve acceptability and use by health professionals. This paper examines on an expectation-confirmation model (ITPAM) the relationships between the determinants of success of a CIS in a cross-sectional survey performed at the Georges Pompidou University Hospital (HEGP). Results for the groups of physicians and nurses that replied to the survey (n=312) suggest that health professional satisfaction (overall R2=0.60) is determined by the quality of user support (r=.21, p=<0001), ease of use (r=.19, p=<0001), confirmation of expectations (r=.15, p=.0037), usefulness (r=.12, p=.0068), and compatibility (r=.10, p=.0206). The best predictor of physician satisfaction (R2=0.71) was compatibility (r=.21, p=.0072) whereas for nurses (R2=0.52) it was user support (r=.22, p=<0001) and ease of use (r=.22, p=.0001). Confirmation of expectations had an impact on post-adoption expectation and user’s satisfaction, and confirms its importance for CIS evaluation studies. PMID:21347045
Clinical information system post-adoption evaluation at the georges pompidou university hospital.
Palm, Jean-Marc; Dart, Thierry; Dupuis, Isabelle; Leneveut, Laurence; Degoulet, Patrice
2010-11-13
The evaluation of a clinical information system (CIS) at different stages of deployment and routine use is a key factor to improve acceptability and use by health professionals. This paper examines on an expectation-confirmation model (ITPAM) the relationships between the determinants of success of a CIS in a cross-sectional survey performed at the Georges Pompidou University Hospital (HEGP). Results for the groups of physicians and nurses that replied to the survey (n=312) suggest that health professional satisfaction (overall R(2)=0.60) is determined by the quality of user support (r=.21, p=<0001), ease of use (r=.19, p=<0001), confirmation of expectations (r=.15, p=.0037), usefulness (r=.12, p=.0068), and compatibility (r=.10, p=.0206). The best predictor of physician satisfaction (R(2)=0.71) was compatibility (r=.21, p=.0072) whereas for nurses (R(2)=0.52) it was user support (r=.22, p=<0001) and ease of use (r=.22, p=.0001). Confirmation of expectations had an impact on post-adoption expectation and user's satisfaction, and confirms its importance for CIS evaluation studies.
Autosophy: an alternative vision for satellite communication, compression, and archiving
NASA Astrophysics Data System (ADS)
Holtz, Klaus; Holtz, Eric; Kalienky, Diana
2006-08-01
Satellite communication and archiving systems are now designed according to an outdated Shannon information theory where all data is transmitted in meaningless bit streams. Video bit rates, for example, are determined by screen size, color resolution, and scanning rates. The video "content" is irrelevant so that totally random images require the same bit rates as blank images. An alternative system design, based on the newer Autosophy information theory, is now evolving, which transmits data "contend" or "meaning" in a universally compatible 64bit format. This would allow mixing all multimedia transmissions in the Internet's packet stream. The new systems design uses self-assembling data structures, which grow like data crystals or data trees in electronic memories, for both communication and archiving. The advantages for satellite communication and archiving may include: very high lossless image and video compression, unbreakable encryption, resistance to transmission errors, universally compatible data formats, self-organizing error-proof mass memories, immunity to the Internet's Quality of Service problems, and error-proof secure communication protocols. Legacy data transmission formats can be converted by simple software patches or integrated chipsets to be forwarded through any media - satellites, radio, Internet, cable - without needing to be reformatted. This may result in orders of magnitude improvements for all communication and archiving systems.
Attitude control of the space construction base: A modular approach
NASA Technical Reports Server (NTRS)
Oconnor, D. A.
1982-01-01
A planar model of a space base and one module is considered. For this simplified system, a feedback controller which is compatible with the modular construction method is described. The systems dynamics are decomposed into two parts corresponding to base and module. The information structure of the problem is non-classical in that not all system information is supplied to each controller. The base controller is designed to accommodate structural changes that occur as the module is added and the module controller is designed to regulate its own states and follow commands from the base. Overall stability of the system is checked by Liapunov analysis and controller effectiveness is verified by computer simulation.
Injector design guidelines for gas/liquid propellant systems
NASA Technical Reports Server (NTRS)
Falk, A. Y.; Burick, R. J.
1973-01-01
Injector design guidelines are provided for gas/liquid propellant systems. Information was obtained from a 30-month applied research program encompassing an analytical, design, and experimental effort to relate injector design parameters to simultaneous attainment of high performance and component (injector/thrust chamber) compatibility for gas/liquid space storable propellants. The gas/liquid propellant combination studied was FLOX (82.6% F2)/ ambient temperature gaseous methane. Design criteria that provide for simultaneous attainment of high performance and chamber compatibility are presented for both injector types. Parametric data are presented that are applicable for the design of circular coaxial and like-doublet injectors that operate with design parameters similar to those employed. However, caution should be exercised when applying these data to propellant combinations whose elements operate in ranges considerably different from those employed in this study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.« less
49 CFR 238.425 - Electrical system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...
49 CFR 238.425 - Electrical system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...
49 CFR 238.425 - Electrical system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...
49 CFR 238.225 - Electrical system.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...
49 CFR 238.425 - Electrical system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...
49 CFR 238.225 - Electrical system.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...
49 CFR 238.225 - Electrical system.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...
49 CFR 238.225 - Electrical system.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...
49 CFR 238.225 - Electrical system.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., and the frames shall be electrically insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility may be achieved...
49 CFR 238.425 - Electrical system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... insulated from the supports that hold them. (d) Electromagnetic interference and compatibility. (1) The operating railroad shall ensure electromagnetic compatibility of the safety-critical equipment systems with their environment. Electromagnetic compatibility can be achieved through equipment design or changes to...
Grudniewicz, Agnes; Tenbensel, Tim; Evans, Jenna M; Steele Gray, Carolyn; Baker, G Ross; Wodchis, Walter P
2018-02-01
Complex adaptive systems (CAS) theory views healthcare as numerous sub-systems characterized by diverse agents that interact, self-organize, and continuously adapt. We apply this complexity science perspective to examine the extent to which CAS theory is a useful lens for designing and implementing health policies. We present the case of Health Links, a "low rules" policy intervention in Ontario, Canada aimed at stimulating the development of voluntary networks of health and social organizations to improve care coordination for the most frequent users of the healthcare system. Our sample consisted of stakeholders from regional governance bodies and organizations partnering in Health Links. Qualitative interview data were coded using the key complexity concepts of sensemaking, self-organization, interconnections, coevolution, and emergence. We found that the complexity-compatible policy design successfully stimulated local dynamics of flexibility, experimentation, and learning and that important mediating factors include leadership, readiness, relationship-building, role clarity, communication, and resources. However, we saw tensions between preferences for flexibility and standardization. Desirable developments occurred only in some settings and failed to flow upward to higher levels, resulting in a piecemeal and patchy landscape. Attention needs to be paid not only to local dynamics and processes, but also to regional and provincial levels to ensure that learning flows to the top and informs decision-making. We conclude that implementation of complexity-compatible policies needs a balance between flexibility and consistency and the right leadership to coordinate the two. Complexity-compatible policy for integrated healthcare is more than simply 'letting a thousand flowers bloom'. Copyright © 2017 Elsevier Ltd. All rights reserved.
Electromagnetic Compatibility Design of the Computer Circuits
NASA Astrophysics Data System (ADS)
Zitai, Hong
2018-02-01
Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.
A mobile information management system used in textile enterprises
NASA Astrophysics Data System (ADS)
Huang, C.-R.; Yu, W.-D.
2008-02-01
The mobile information management system (MIMS) for textile enterprises is based on Microsoft Visual Studios. NET2003 Server, Microsoft SQL Server 2000, C++ language and wireless application protocol (WAP) and wireless markup language (WML) technology. The portable MIMS is composed of three-layer structures, i.e. showing layer; operating layer; and data visiting layer corresponding to the port-link module; processing module; and database module. By using the MIMS, not only the information exchanges become more convenient and easier, but also the compatible between the giant information capacity and a micro-cell phone and functional expansion nature in operating and designing can be realized by means of build-in units. The development of MIMS is suitable for the utilization in textile enterprises.
1985-12-01
85 UNCLSSIFIED F/ 3/2 NL mhhhhhhhhhhhhl 4y 1.0 &32 MICROCOPY RESOLUTIOf TEST CKART. N NAVAL POSTGRADUATE SCHOOL Monterey, California DTIC ELECTE...Concern over corporate information resources has resulted from the explosive growth in the size, complexity and number of data bases available to...validity, and relevance, and usability of the data that is available. As a result , there has been a growing interest in two tools which .,%... provide
Off-design temperature effects on nuclear fuel pins for an advanced space-power-reactor concept
NASA Technical Reports Server (NTRS)
Bowles, K. J.
1974-01-01
An exploratory out-of-reactor investigation was made of the effects of short-time temperature excursions above the nominal operating temperature of 990 C on the compatibility of advanced nuclear space-power reactor fuel pin materials. This information is required for formulating a reliable reactor safety analysis and designing an emergency core cooling system. Simulated uranium mononitride (UN) fuel pins, clad with tungsten-lined T-111 (Ta-8W-2Hf) showed no compatibility problems after heating for 8 hours at 2400 C. At 2520 C and above, reactions occurred in 1 hour or less. Under these conditions free uranium formed, redistributed, and attacked the cladding.
Mating compatibility in the parasitic protist Trypanosoma brucei.
Peacock, Lori; Ferris, Vanessa; Bailey, Mick; Gibson, Wendy
2014-02-21
Genetic exchange has been described in several kinetoplastid parasites, but the most well-studied mating system is that of Trypanosoma brucei, the causative organism of African sleeping sickness. Sexual reproduction takes place in the salivary glands (SG) of the tsetse vector and involves meiosis and production of haploid gametes. Few genetic crosses have been carried out to date and consequently there is little information about the mating compatibility of different trypanosomes. In other single-celled eukaryotes, mating compatibility is typically determined by a system of two or more mating types (MT). Here we investigated the MT system in T. brucei. We analysed a large series of F1, F2 and back crosses by pairwise co-transmission of red and green fluorescent cloned cell lines through experimental tsetse flies. To analyse each cross, trypanosomes were cloned from fly SG containing a mixture of both parents, and genotyped by microsatellites and molecular karyotype. To investigate mating compatibility at the level of individual cells, we directly observed the behaviour of SG-derived gametes in intra- or interclonal mixtures of red and green fluorescent trypanosomes ex vivo. Hybrid progeny were found in all F1 and F2 crosses and most of the back crosses. The success of individual crosses was highly variable as judged by the number of hybrid clones produced, suggesting a range of mating compatibilities among F1 progeny. As well as hybrids, large numbers of recombinant genotypes resulting from intraclonal mating (selfers) were found in some crosses. In ex vivo mixtures, red and green fluorescent trypanosome gametes were observed to pair up and interact via their flagella in both inter- and intraclonal combinations. While yellow hybrid trypanosomes were frequently observed in interclonal mixtures, such evidence of cytoplasmic exchange was rare in the intraclonal mixtures. The outcomes of individual crosses, particularly back crosses, were variable in numbers of both hybrid and selfer clones produced, and do not readily fit a simple two MT model. From comparison of the behaviour of trypanosome gametes in inter- and intraclonal mixtures, we infer that mating compatibility is controlled at the level of gamete fusion.
Mating compatibility in the parasitic protist Trypanosoma brucei
2014-01-01
Background Genetic exchange has been described in several kinetoplastid parasites, but the most well-studied mating system is that of Trypanosoma brucei, the causative organism of African sleeping sickness. Sexual reproduction takes place in the salivary glands (SG) of the tsetse vector and involves meiosis and production of haploid gametes. Few genetic crosses have been carried out to date and consequently there is little information about the mating compatibility of different trypanosomes. In other single-celled eukaryotes, mating compatibility is typically determined by a system of two or more mating types (MT). Here we investigated the MT system in T. brucei. Methods We analysed a large series of F1, F2 and back crosses by pairwise co-transmission of red and green fluorescent cloned cell lines through experimental tsetse flies. To analyse each cross, trypanosomes were cloned from fly SG containing a mixture of both parents, and genotyped by microsatellites and molecular karyotype. To investigate mating compatibility at the level of individual cells, we directly observed the behaviour of SG-derived gametes in intra- or interclonal mixtures of red and green fluorescent trypanosomes ex vivo. Results Hybrid progeny were found in all F1 and F2 crosses and most of the back crosses. The success of individual crosses was highly variable as judged by the number of hybrid clones produced, suggesting a range of mating compatibilities among F1 progeny. As well as hybrids, large numbers of recombinant genotypes resulting from intraclonal mating (selfers) were found in some crosses. In ex vivo mixtures, red and green fluorescent trypanosome gametes were observed to pair up and interact via their flagella in both inter- and intraclonal combinations. While yellow hybrid trypanosomes were frequently observed in interclonal mixtures, such evidence of cytoplasmic exchange was rare in the intraclonal mixtures. Conclusions The outcomes of individual crosses, particularly back crosses, were variable in numbers of both hybrid and selfer clones produced, and do not readily fit a simple two MT model. From comparison of the behaviour of trypanosome gametes in inter- and intraclonal mixtures, we infer that mating compatibility is controlled at the level of gamete fusion. PMID:24559099
2009-09-01
OF A LINK-16/JTIDS COMPATIBLE WAVEFORM WITH NONCOHERENT DETECTION, DIVERSITY AND SIDE INFORMATION by Ioannis Kagioglidis September 2009... Noncoherent Detection, Diversity and Side Information. 6. AUTHOR Ioannis Kagioglidis 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...baseband waveforms and detected noncoherently . For noncoherent detection, only one five bit symbol is transmitted on both the I and Q components of
HAL/S-360 compiler system specification
NASA Technical Reports Server (NTRS)
Johnson, A. E.; Newbold, P. N.; Schulenberg, C. W.; Avakian, A. E.; Varga, S.; Helmers, P. H.; Helmers, C. T., Jr.; Hotz, R. L.
1974-01-01
A three phase language compiler is described which produces IBM 360/370 compatible object modules and a set of simulation tables to aid in run time verification. A link edit step augments the standard OS linkage editor. A comprehensive run time system and library provide the HAL/S operating environment, error handling, a pseudo real time executive, and an extensive set of mathematical, conversion, I/O, and diagnostic routines. The specifications of the information flow and content for this system are also considered.
NASA Technical Reports Server (NTRS)
1986-01-01
System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.
Olcott, Peter D; Peng, Hao; Levin, Craig S
2009-01-01
A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.
HAL/S-FC compiler system specifications
NASA Technical Reports Server (NTRS)
1976-01-01
This document specifies the informational interfaces within the HAL/S-FC compiler, and between the compiler and the external environment. This Compiler System Specification is for the HAL/S-FC compiler and its associated run time facilities which implement the full HAL/S language. The HAL/S-FC compiler is designed to operate stand-alone on any compatible IBM 360/370 computer and within the Software Development Laboratory (SDL) at NASA/JSC, Houston, Texas.
Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.
Schmidt, Ehud J; Tse, Zion T H; Reichlin, Tobias R; Michaud, Gregory F; Watkins, Ronald D; Butts-Pauly, Kim; Kwong, Raymond Y; Stevenson, William; Schweitzer, Jeffrey; Byrd, Israel; Dumoulin, Charles L
2014-03-01
Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. An MRI-compatible VDT system is feasible. Copyright © 2013 Wiley Periodicals, Inc.
Voltage-based Device Tracking in a 1.5 Tesla MRI during Imaging: Initial validation in swine models
Schmidt, Ehud J; Tse, Zion TH; Reichlin, Tobias R; Michaud, Gregory F; Watkins, Ronald D; Butts-Pauly, Kim; Kwong, Raymond Y; Stevenson, William; Schweitzer, Jeffrey; Byrd, Israel; Dumoulin, Charles L
2013-01-01
Purpose Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological (EP) cardiac-arrhythmia therapy. During EP procedures, electro-anatomic-mapping (EAM) workstations provide guidance by integrating VDT location and intra-cardiac-ECG information with X-ray, CT, Ultrasound, and MR images. MR assists navigation, mapping and radio-frequency-ablation. Multi-modality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound EP suite, increasing the likelihood of patient-motion and image mis-registration. An MRI-compatible VDT system may increase efficiency, since there is currently no single method to track devices both inside and outside the MRI scanner. Methods An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radio-frequency-unblanking-pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT EAM-mapping interventions were performed, navigating inside and thereafter outside the MRI. Results Three-catheter VDT interventions were performed at >12 frames-per-second both inside and outside the MRI scanner with <3mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition-time (TR) >32 msec sequences with <0.5mm errors, and <5% MRI SNR loss. At shorter TRs, only intra-cardiac-ECG was reliable. RF Heating was <1.5C°. Conclusion An MRI-compatible VDT system is feasible. PMID:23580479
76 FR 46798 - Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-UST-2010-0651; FRL-9447-3] Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction AGENCY: Environmental Protection Agency (EPA). ACTION... of underground storage tanks (USTs) can demonstrate compliance with the Federal compatibility...
Hubert, Terrance D.; Boogaard, Michael A.; Fredricks, Kim T.
2016-01-14
Compatibility of the various options was also evaluated to assess the possibility that options could be combined to enhance efficacy. Engineering requirements were not considered as part of this evaluation. The available information suggests that hot water at 43 °C and ozone are the most feasible options.
Taiwo Adeleke, Ibrahim; Hakeem Lawal, Adedeji; Adetona Adio, Razzaq; Adisa Adebisi, AbdulLateef
There is a lack of effective health information management systems in Nigeria due to the prevalence of cumbersome paper-based and disjointed health data management systems. This can make informed healthcare decision making difficult. This study examined the information technology (IT) skills, utilisation and training needs of Nigerian health information management professionals. We deployed a cross-sectional structured questionnaire to determine the IT skills and training needs of health information management professionals who have leadership roles in the nation's healthcare information systems (n=374). It was found that ownership of a computer, level of education and age were associated with knowledge and perception of IT. The vast majority of participants (98.8%) acknowledged the importance and relevance of IT in healthcare information systems and many expressed a desire for further IT training, especially in statistical analysis. Despite this, few (8.1 %) worked in settings where such systems operate and there exists an IT skill gap among these professionals which is not compatible with their roles in healthcare information systems. To rectify this anomaly they require continuing professional development education, especially in the areas of health IT. Government intervention in the provision of IT infrastructure in order to put into practice a computerised healthcare information system would therefore be a worthwhile undertaking.
Factors shaping the evolution of electronic documentation systems
NASA Technical Reports Server (NTRS)
Dede, Christopher J.; Sullivan, Tim R.; Scace, Jacque R.
1990-01-01
The main goal is to prepare the space station technical and managerial structure for likely changes in the creation, capture, transfer, and utilization of knowledge. By anticipating advances, the design of Space Station Project (SSP) information systems can be tailored to facilitate a progression of increasingly sophisticated strategies as the space station evolves. Future generations of advanced information systems will use increases in power to deliver environmentally meaningful, contextually targeted, interconnected data (knowledge). The concept of a Knowledge Base Management System is emerging when the problem is focused on how information systems can perform such a conversion of raw data. Such a system would include traditional management functions for large space databases. Added artificial intelligence features might encompass co-existing knowledge representation schemes; effective control structures for deductive, plausible, and inductive reasoning; means for knowledge acquisition, refinement, and validation; explanation facilities; and dynamic human intervention. The major areas covered include: alternative knowledge representation approaches; advanced user interface capabilities; computer-supported cooperative work; the evolution of information system hardware; standardization, compatibility, and connectivity; and organizational impacts of information intensive environments.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
... 11-153] Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics... substantially affect compatibility between cable service and consumer electronics equipment for most subscribers... problems between cable service and consumer electronics equipment were limiting and/or precluding the...
Towards simultaneous single emission microscopy and magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Cai, Liang
In recent years, the combined nuclear imaging and magnetic resonance imaging (MRI) has drawn extensive research effort. They can provide simultaneously acquired anatomical and functional information inside the human/small animal body in vivo. In this dissertation, the development of an ultrahigh resolution MR-compatible SPECT (Single Photon Emission Computed Tomography) system that can be operated inside a pre-existing clinical MR scanner for simultaneous dual-modality imaging of small animals will be discussed. This system is constructed with 40 small pixel CdTe detector modules assembled in a fully stationary ring SPECT geometry. Series of experiments have demonstrated that this system is capable of providing an imaging resolution of <500?m, when operated inside MR scanners. The ultrahigh resolution MR-compatible SPECT system is built around a small pixel CdTe detector module that we recently developed. Each module consists of CdTe detectors having an overall size of 2.2 cm x 1.1 cm, divided into 64 x 32 pixels of 350 mum in size. A novel hybrid pixel-waveform (HPWF) readout system is also designed to alleviate several challenges for using small-pixel CdTe detectors in ultrahigh-resolution SPECT imaging applications. The HPWF system utilizes a modified version of a 2048-channel 2-D CMOS ASIC to readout the anode pixel, and a digitizing circuitry to sample the signal waveform induced on the cathode. The cathode waveform acquired with the HPWF circuitry offers excellent spatial resolution, energy resolution and depth of interaction (DOI) information, even with the presence of excessive charge-sharing/charge-loss between the small anode pixels. The HPWF CdTe detector is designed and constructed with a minimum amount of ferromagnetic materials, to ensure the MR-compatibility. To achieve sub-500?m imaging resolution, two special designed SPECT apertures have been constructed with different pinhole sizes of 300?m and 500?m respectively. It has 40 pinhole inserts that are made of cast platinum (90%)-iridium (10%) alloy, which provides the maximum stopping power and are compatible with MR scanners. The SPECT system is installed on a non-metal gantry constructed with 3-D printing using nylon powder material. This compact system can work as a "low-cost" desktop ultrahigh resolution SPECT system. It can also be directly operated inside an MR scanner. Accurate system geometrical calibration and corresponding image reconstruction methods for the MRC-SPECT system is developed. In order to account for the magnetic field induced distortion in the SPECT image, a comprehensive charge collection model inside strong magnetic field is adopted to produce high resolution SPECT image inside MR scanner.
2011-01-01
Background Integration of compatible or incompatible emotional valence and semantic information is an essential aspect of complex social interactions. A modified version of the Implicit Association Test (IAT) called Dual Valence Association Task (DVAT) was designed in order to measure conflict resolution processing from compatibility/incompatibly of semantic and facial valence. The DVAT involves two emotional valence evaluative tasks which elicits two forms of emotional compatible/incompatible associations (facial and semantic). Methods Behavioural measures and Event Related Potentials were recorded while participants performed the DVAT. Results Behavioural data showed a robust effect that distinguished compatible/incompatible tasks. The effects of valence and contextual association (between facial and semantic stimuli) showed early discrimination in N170 of faces. The LPP component was modulated by the compatibility of the DVAT. Conclusions Results suggest that DVAT is a robust paradigm for studying the emotional interference effect in the processing of simultaneous information from semantic and facial stimuli. PMID:21489277
Nonlinear stress waves in a perfectly flexible string. [for aerodynamic decelerating system
NASA Technical Reports Server (NTRS)
Fan, D.-N.; Mcgarvey, J. F.
1977-01-01
This paper discusses nonlinear stress-wave propagation in a perfectly flexible string obeying a quasilinear (rate-dependent) constitutive equation. Wave speeds and compatibility relations valid along various families of characteristics were determined. It was shown that the compatibility relations associated with the transverse as well as the longitudinal waves readily yield a physical interpretation when they are expressed in suitable variables and in vector form. Coding based on the present information was completed for the machine solution of a class of mixed initial- and boundary-value problems of practical interest. Computer simulation of the stress-wave interaction in the 40-foot lanyard in the Arcas 'Rocoz' system during deployment was carried out using a stress-strain relation for nylon at the strain rate of 30/second. A method for estimating the maximum tension and strain in a string during the initial loading phase is proposed.
Special report writer: A flexible information management system. Documentation and user's manual
NASA Technical Reports Server (NTRS)
Greene, W. A.
1976-01-01
A special report writer (SSR) was developed which performs multiple correlations on files containing several data hierarchies. Output reports are specified in a simple notation, readily learned by persons having limited familarity with ADP. The SRR system can be adopted by other NASA installations while the basic techniques themselves are compatible with the information management needs of a wide range of organizations. Specifically, the program lends itself to generalization and can be readily adapted for other file management purposes. Extensive details on the characteristics of the SRR program are presented along with a full explanation of the system for those contemplating its application to other data bases. The complete COBOL program and documentation are available.
Processable Data Making in the Remote Server Sent by Android Phone as a GIS Data Collecting Tool
NASA Astrophysics Data System (ADS)
Karaagac, Abdullah; Bostancı, Bulent
2016-04-01
Mobile technologies are improving and getting cheaper everyday. Not only smart phones are improved much but also new types of mobile applications and sensors come with the smart phone together. Maps and navigation applications one of the most popular types of applications on these types. Most of these applications uses location services including GNSS, Wi Fi, cellular data and beacon services. Although these coordinate precision not very high, it is appropriate for many applications to utilize. Android is a mobile operating system based on Linux Kernel. It is compatible for varies mobile devices like smart phones, tablets, smart TV's, wearable technologies etc. Android has large capability for application development by using the open source libraries and device sensors like gyroscope, GNSS etc. Android Studio is the most popular integrated development environment (IDE) for Android devices, mainly developing by Google. It had been announced on May 16, 2013 at Google I/O conference. Android Studio is built upon Gradle architecture which is written in Java language. SQLite is a relational database operating system which has so common usage for mobile devices. It developed by using C programming library. It is mostly used via embedding into a software or application. It supports many operating systems including Android. Remote servers can be in several forms from high complexity to simplicity. For this project we will use a open source quad core board computer named Raspberry Pi 2. This device includes 900 MHz ARMv7 compatible quad core CPU, VideoCore IV GPU and 1 GB RAM. Although Raspberry Pi 2's main operating system is Raspbian, we use Debian which are both Linux based operating systems. Raspberry is compatible for many programming language, however some languages are optimized for this device. These are Python, Java, C, C++, Ruby, Perl and Squeak Smalltalk. In this paper, a mobile application will be developed to send coordinate and string data to a SQL database embedded to a remote server. The application will run on Android Operating System running mobile phone. The application will get the location information from the GNSS and cellular data. The user will enter the other information individually. These information will send by clicking a button to remote server which runs SQLite. All these informations will be convertible to any type of measure like type of coordinates could be converted from WGS 84 to ITRF.
Delivery of laboratory data with World Wide Web technology.
Hahn, A W; Leon, M A; Klein-Leon, S; Allen, G K; Boon, G D; Patrick, T B; Klimczak, J C
1997-01-01
We have developed an experimental World Wide Web (WWW) based system to deliver laboratory results to clinicians in our Veterinary Medical Teaching Hospital. Laboratory results are generated by the clinical pathology section of our Veterinary Medical Diagnostic Laboratory and stored in a legacy information system. This system does not interface directly to the hospital information system, and it cannot be accessed directly by clinicians. Our "meta" system first parses routine print reports and then instantiates the data into a modern, open-architecture relational database using a data model constructed with currently accepted international standards for data representation and communication. The system does not affect either of the existing legacy systems. Location-independent delivery of patient data is via a secure WWW based system which maximizes usability and allows "value-added" graphic representations. The data can be viewed with any web browser. Future extensibility and intra- and inter-institutional compatibility served as key design criteria. The system is in the process of being evaluated using accepted methods of assessment of information technologies.
Photogrammetric mapping for cadastral land information systems
NASA Astrophysics Data System (ADS)
Muzakidis, Panagiotis D.
The creation of a "clean" digital database is a most important and complex task, upon which the usefulness of a Parcel-Based Land Information System depends. Capturing data by photogrammetric methods for cadastral purposes necessitates the transformation of data into a computer compatible form. Such input requires the encoding, editing and structuring of data. The research is carried out in two phases, the first is concerned with defining the data modelling schemes and the classification of basic data for a parcel-based land information system together with the photogrammetric methods to be adopted to collect these data. The second deals with data editing and data structuring processes in order to produce "clean" information relevant to such a system. Implementation of the proposed system at both the data collection stage and within the data processing stage itself demands a number of flexible criteria to be defined within the methodology. Development of these criteria will include consideration of the cadastral characteristics peculiar to Greece.
Power processor for a 30cm ion thruster
NASA Technical Reports Server (NTRS)
Biess, J. J.; Inouye, L. Y.
1974-01-01
A thermal vacuum power processor for the NASA Lewis 30cm Mercury Ion Engine was designed, fabricated and tested to determine compliance with electrical specifications. The power processor breadboard used the silicon controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to an ion engine. The power processor includes a digital interface unit to process all input commands and internal telemetry signals so that operation is compatible with a central computer system. The breadboard was tested in a thermal vacuum environment. Integration tests were performed with the ion engine and demonstrate operational compatibility and reliable operation without any component failures. Electromagnetic interference data were also recorded on the design to provide information on the interaction with total spacecraft.
Resource Sharing of Micro-Software, or, What Ever Happened to All That CP/M Compatibility?
ERIC Educational Resources Information Center
DeYoung, Barbara
1984-01-01
Explores incompatible operating systems as the basic reason why software packages will not work on different microcomputers; defines operating system; explores compatibility issues surrounding the IBM MS-DOS; and presents two future trends in hardware and software developments which indicate a return to true compatibility. (Author/MBR)
Legally compatible design of digital dactyloscopy in future surveillance scenarios
NASA Astrophysics Data System (ADS)
Pocs, Matthias; Schott, Maik; Hildebrandt, Mario
2012-06-01
Innovation in multimedia systems impacts on our society. For example surveillance camera systems combine video and audio information. Currently a new sensor for capturing fingerprint traces is being researched. It combines greyscale images to determine the intensity of the image signal, on one hand, and topographic information to determine fingerprint texture on a variety of surface materials, on the other. This research proposes new application areas which will be analyzed from a technical-legal view point. It assesses how technology design can promote legal criteria of German and European privacy and data protection. For this we focus on one technology goal as an example.
ERIC Educational Resources Information Center
Bardwell, John D.
This study sought to identify physical facilities needed to connect the six New England land-grant universities. Criteria were time (use of current technology), cost (regular operating budgets of participating institutions), minimal personnel requirements, flexibility, and compatibility. The telephone system, an existing microwave network, a…
A haptic unit designed for magnetic-resonance-guided biopsy.
Tse, Z T H; Elhawary, H; Rea, M; Young, I; Davis, B L; Lamperth, M
2009-02-01
The magnetic fields present in the magnetic resonance (MR) environment impose severe constraints on any mechatronic device present in its midst, requiring alternative actuators, sensors, and materials to those conventionally used in traditional system engineering. In addition the spatial constraints of closed-bore scanners require a physical separation between the radiologist and the imaged region of the patient. This configuration produces a loss of the sense of touch from the target anatomy for the clinician, which often provides useful information. To recover the force feedback from the tissue, an MR-compatible haptic unit, designed to be integrated with a five-degrees-of-freedom mechatronic system for MR-guided prostate biopsy, has been developed which incorporates position control and force feedback to the operator. The haptic unit is designed to be located inside the scanner isocentre with the master console in the control room. MR compatibility of the device has been demonstrated, showing a negligible degradation of the signal-to-noise ratio and virtually no geometric distortion. By combining information from the position encoder and force sensor, tissue stiffness measurement along the needle trajectory is demonstrated in a lamb liver to aid diagnosis of suspected cancerous tissue.
Development Of The Drexler Optical-Card Reader/Writer System
NASA Astrophysics Data System (ADS)
Pierce, Gerald A.
1988-06-01
An optical-card reader/writer optical and electronic breadboard system, developed by SRI International under contract to Drexler Technology, is described. The optical card, which is the same size as a credit card, can contain more than 2 megabytes of digital user data, which may also include preformatted tracking information and preformatted data. The data layout on the card is similar to that on a floppy disk, with each track containing a header and clocking information. The design of this optical reader/writer system for optical cards is explained. Design of the optical card system entails a number of unique issues: To accommodate both laser-recorded and mass-duplicated information, the system must be compatible with preencoded information, which implies a larger-than-normal spot size (5 gm) and a detection system that can read both types of optical patterns. Cost-reduction considerations led to selection of a birefringent protection layer, which dictated a nonstandard optical system. The non-polarization-sensitive optics use an off-axis approach to detection. An LED illumination system makes it possible to read multiple tracks.
A proposal for cervical screening information systems in developing countries.
Marrett, Loraine D; Robles, Sylvia; Ashbury, Fredrick D; Green, Bo; Goel, Vivek; Luciani, Silvana
2002-11-20
The effective and efficient delivery of cervical screening programs requires information for planning, management, delivery and evaluation. Specially designed systems are generally required to meet these needs. In many developing countries, lack of information systems constitutes an important barrier to development of comprehensive screening programs and the effective control of cervical cancer. Our report outlines a framework for creating such systems in developing countries and describes a conceptual model for a cervical screening information system. The proposed system is modular, recognizing that there will be considerable between-region heterogeneity in current status and priorities. The proposed system is centered on modules that would allow for the assembly and computerization of data on Pap tests, since these represent the main screening modality at the present time. Additional modules would process data and create and maintain a screening database (e.g., standardize, edit, link and update modules) and allow for the integration of other types of data, such as cervical histopathology results. An open systems development model is proposed, since it is most compatible with the goals of local stakeholder involvement and capacity-building. Copyright 2002 Wiley-Liss, Inc.
A study of ionospheric grid modification technique for BDS/GPS receiver
NASA Astrophysics Data System (ADS)
Liu, Xuelin; Li, Meina; Zhang, Lei
2017-07-01
For the single-frequency GPS receiver, ionospheric delay is an important factor affecting the positioning performance. There are many kinds of ionospheric correction methods, common models are Bent model, IRI model, Klobuchar model, Ne Quick model and so on. The US Global Positioning System (GPS) uses the Klobuchar coefficients transmitted in the satellite signal to correct the ionospheric delay error for a single frequency GPS receiver, but this model can only reduce the ionospheric error of about 50% in the mid-latitudes. In the Beidou system, the accuracy of the correction delay is higher. Therefore, this paper proposes a method that using BD grid information to correct GPS ionospheric delay to improve the ionospheric delay for the BDS/GPS compatible positioning receiver. In this paper, the principle of ionospheric grid algorithm is introduced in detail, and the positioning accuracy of GPS system and BDS/GPS compatible positioning system is compared and analyzed by the real measured data. The results show that the method can effectively improve the positioning accuracy of the receiver in a more concise way.
Broadcasting GPS integrity information using Loran-C
NASA Astrophysics Data System (ADS)
Lo, Sherman Chih
The United States Federal Aviation Administration (FAA) will adopt the Global Positioning System (GPS) as its primary navigation systems for aviation as stated by the Federal Radionavigation Plans (FRP) of 1996 and 1999. The FRP also proposes the reduction or termination of some existing radionavigation system in favor of GPS and satellite navigation. It may be beneficial to retain some of these existing terrestrial navigation systems if they can provide increased safety and redundancy to the GPS based architecture. One manner in which this can be done is by using or creating a data link on these existing radionavigation systems. These systems thus can provide both navigation and an additional broadcast of GPS integrity information. This thesis examines the use of terrestrial data links to provide Wide Area Augmentation System (WAAS) based GPS integrity information for aviation. The thesis focuses on using Loran-C to broadcast WAAS data. Analysis and experimental results demonstrating the capabilities of these designs are also discussed. Using Loran for this purpose requires increasing its data capacity. Many Loran modulation schemes are developed and analyzed. The data rates developed significantly increased the Loran data capacity. However, retaining compatibility with Loran legacy users resulted in data rates below the WARS data rate of 250 bps. As a result, this thesis also examines means of reducing the data requirements for WAAS information. While higher data rates offer improved performance and compatibility with WAAS, this thesis demonstrates that higher rates incur greater interference. Therefore, this work develops and considers a 108 bps and 167 bps Loran GPS integrity channel (LOGIC) design. The performance of the two designs illustrates some of the advantages and disadvantages of using a higher data rate. Analysis demonstrated means of maintaining integrity with these low data rate systems and determined the theoretical capabilities of the systems. The system was tested empirically by developing software that generated the LOGIC message and applied these messages to a GPS user. The resulting 108 bps and 167 bps systems demonstrated capability to provide lateral navigation/vertical navigation (LNAV/VNAV) and approach with vertical guidance (APV) respectively.
A System for Information Management in BioMedical Studies—SIMBioMS
Krestyaninova, Maria; Zarins, Andris; Viksna, Juris; Kurbatova, Natalja; Rucevskis, Peteris; Neogi, Sudeshna Guha; Gostev, Mike; Perheentupa, Teemu; Knuuttila, Juha; Barrett, Amy; Lappalainen, Ilkka; Rung, Johan; Podnieks, Karlis; Sarkans, Ugis; McCarthy, Mark I; Brazma, Alvis
2009-01-01
Summary: SIMBioMS is a web-based open source software system for managing data and information in biomedical studies. It provides a solution for the collection, storage, management and retrieval of information about research subjects and biomedical samples, as well as experimental data obtained using a range of high-throughput technologies, including gene expression, genotyping, proteomics and metabonomics. The system can easily be customized and has proven to be successful in several large-scale multi-site collaborative projects. It is compatible with emerging functional genomics data standards and provides data import and export in accepted standard formats. Protocols for transferring data to durable archives at the European Bioinformatics Institute have been implemented. Availability: The source code, documentation and initialization scripts are available at http://simbioms.org. Contact: support@simbioms.org; mariak@ebi.ac.uk PMID:19633095
Purdon, Patrick L.; Millan, Hernan; Fuller, Peter L.; Bonmassar, Giorgio
2008-01-01
Simultaneous recording of electrophysiology and functional magnetic resonance imaging (fMRI) is a technique of growing importance in neuroscience. Rapidly evolving clinical and scientific requirements have created a need for hardware and software that can be customized for specific applications. Hardware may require customization to enable a variety of recording types (e.g., electroencephalogram, local field potentials, or multi-unit activity) while meeting the stringent and costly requirements of MRI safety and compatibility. Real-time signal processing tools are an enabling technology for studies of learning, attention, sleep, epilepsy, neurofeedback, and neuropharmacology, yet real-time signal processing tools are difficult to develop. We describe an open source system for simultaneous electrophysiology and fMRI featuring low-noise (< 0.6 uV p-p input noise), electromagnetic compatibility for MRI (tested up to 7 Tesla), and user-programmable real-time signal processing. The hardware distribution provides the complete specifications required to build an MRI-compatible electrophysiological data acquisition system, including circuit schematics, print circuit board (PCB) layouts, Gerber files for PCB fabrication and robotic assembly, a bill of materials with part numbers, data sheets, and vendor information, and test procedures. The software facilitates rapid implementation of real-time signal processing algorithms. This system has used in human EEG/fMRI studies at 3 and 7 Tesla examining the auditory system, visual system, sleep physiology, and anesthesia, as well as in intracranial electrophysiological studies of the non-human primate visual system during 3 Tesla fMRI, and in human hyperbaric physiology studies at depths of up to 300 feet below sea level. PMID:18761038
Purdon, Patrick L; Millan, Hernan; Fuller, Peter L; Bonmassar, Giorgio
2008-11-15
Simultaneous recording of electrophysiology and functional magnetic resonance imaging (fMRI) is a technique of growing importance in neuroscience. Rapidly evolving clinical and scientific requirements have created a need for hardware and software that can be customized for specific applications. Hardware may require customization to enable a variety of recording types (e.g., electroencephalogram, local field potentials, or multi-unit activity) while meeting the stringent and costly requirements of MRI safety and compatibility. Real-time signal processing tools are an enabling technology for studies of learning, attention, sleep, epilepsy, neurofeedback, and neuropharmacology, yet real-time signal processing tools are difficult to develop. We describe an open-source system for simultaneous electrophysiology and fMRI featuring low-noise (<0.6microV p-p input noise), electromagnetic compatibility for MRI (tested up to 7T), and user-programmable real-time signal processing. The hardware distribution provides the complete specifications required to build an MRI-compatible electrophysiological data acquisition system, including circuit schematics, print circuit board (PCB) layouts, Gerber files for PCB fabrication and robotic assembly, a bill of materials with part numbers, data sheets, and vendor information, and test procedures. The software facilitates rapid implementation of real-time signal processing algorithms. This system has been used in human EEG/fMRI studies at 3 and 7T examining the auditory system, visual system, sleep physiology, and anesthesia, as well as in intracranial electrophysiological studies of the non-human primate visual system during 3T fMRI, and in human hyperbaric physiology studies at depths of up to 300 feet below sea level.
Are Automatic Imitation and Spatial Compatibility Mediated by Different Processes?
ERIC Educational Resources Information Center
Cooper, Richard P.; Catmur, Caroline; Heyes, Cecilia
2013-01-01
Automatic imitation or "imitative compatibility" is thought to be mediated by the mirror neuron system and to be a laboratory model of the motor mimicry that occurs spontaneously in naturalistic social interaction. Imitative compatibility and spatial compatibility effects are known to depend on different stimulus dimensions--body…
Fully CMOS-compatible titanium nitride nanoantennas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Briggs, Justin A., E-mail: jabriggs@stanford.edu; Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, California 94305; Naik, Gururaj V.
CMOS-compatible fabrication of plasmonic materials and devices will accelerate the development of integrated nanophotonics for information processing applications. Using low-temperature plasma-enhanced atomic layer deposition (PEALD), we develop a recipe for fully CMOS-compatible titanium nitride (TiN) that is plasmonic in the visible and near infrared. Films are grown on silicon, silicon dioxide, and epitaxially on magnesium oxide substrates. By optimizing the plasma exposure per growth cycle during PEALD, carbon and oxygen contamination are reduced, lowering undesirable loss. We use electron beam lithography to pattern TiN nanopillars with varying diameters on silicon in large-area arrays. In the first reported single-particle measurements onmore » plasmonic TiN, we demonstrate size-tunable darkfield scattering spectroscopy in the visible and near infrared regimes. The optical properties of this CMOS-compatible material, combined with its high melting temperature and mechanical durability, comprise a step towards fully CMOS-integrated nanophotonic information processing.« less
Modulation and coding for a compatible Discrete Address Beacon System.
DOT National Transportation Integrated Search
1972-02-01
One of several possible candidate configurations for the Discrete Address System is described. The configuration presented is compatible with the Air Traffic Control Radar Beacon System, and it provides for gradual transition from one system to the o...
Electronic systems failures and anomalies attributed to electromagnetic interference
NASA Technical Reports Server (NTRS)
Leach, R. D. (Editor); Alexander, M. B. (Editor)
1995-01-01
The effects of electromagnetic interference can be very detrimental to electronic systems utilized in space missions. Assuring that subsystems and systems are electrically compatible is an important engineering function necessary to assure mission success. This reference publication will acquaint the reader with spacecraft electronic systems failures and anomalies caused by electromagnetic interference and will show the importance of electromagnetic compatibility activities in conjunction with space flight programs. It is also hoped that the report will illustrate that evolving electronic systems are increasingly sensitive to electromagnetic interference and that NASA personnel must continue to diligently pursue electromagnetic compatibility on space flight systems.
Telecommunications Systems Design Techniques Handbook
NASA Technical Reports Server (NTRS)
Edelson, R. E. (Editor)
1972-01-01
The Deep Space Network (DSN) increasingly supports deep space missions sponsored and managed by organizations without long experience in DSN design and operation. The document is intended as a textbook for those DSN users inexperienced in the design and specification of a DSN-compatible spacecraft telecommunications system. For experienced DSN users, the document provides a reference source of telecommunication information which summarizes knowledge previously available only in a multitude of sources. Extensive references are quoted for those who wish to explore specific areas more deeply.
Skylab food system laboratory support
NASA Technical Reports Server (NTRS)
Sanford, D.
1974-01-01
A summary of support activities performed to ensure the quality and reliability of the Skylab food system design is reported. The qualification test program was conducted to verify crew compartment compatibility, and to certify compliance of the food system with nutrition, preparation, and container requirements. Preflight storage requirements and handling procedures were also determined. Information on Skylab food items was compiled including matters pertaining to serving size, preparation information, and mineral, calorie, and protein content. Accessory hardware and the engraving of food utensils were also considered, and a stowage and orientation list was constructed which takes into account menu use sequences, menu items, and hardware stowage restrictions. A food inventory system was established and food thermal storage tests were conducted. Problems and comments pertaining to specific food items carried onboard the Skylab Workshop were compiled.
Listening to the user: A case study
NASA Technical Reports Server (NTRS)
Pryor, H. E.
1976-01-01
The managers of the NASA Scientific and Technical Information System consistently maintain that whatever scientific and technical information services and products are provided must be geared primarily to user needs and not simply system compatibility and convenience. A system evaluation study begun in 1973 and continued to the present is described. The thrust of this on-going examination is to regularly evaluate the usefulness of the present information system to those it is intended to serve, engineers and scientists working in their professional roles, and to identify areas and ways in which the system can be made more responsive to user needs. Techniques used have covered the range from personal, in-depth interviews to widely distributed questionnaires. The findings have been positive. Many refinements made to on-going programs and projects and new endeavors begun in direct response to stated user needs are discussed. In the main these needs are not unreasonable and thus can be responded to with cost effective system modifications.
Study and design of cryogenic propellant acquisition systems. Volume 1: Design studies
NASA Technical Reports Server (NTRS)
Burge, G. W.; Blackmon, J. B.
1973-01-01
An in-depth study and selection of practical propellant surface tension acquisition system designs for two specific future cryogenic space vehicles, an advanced cryogenic space shuttle auxiliary propulsion system and an advanced space propulsion module is reported. A supporting laboratory scale experimental program was also conducted to provide design information critical to concept finalization and selection. Designs using localized pressure isolated surface tension screen devices were selected for each application and preliminary designs were generated. Based on these designs, large scale acquisition prototype hardware was designed and fabricated to be compatible with available NASA-MSFC feed system hardware.
Technology assessment--who is getting stuck, anyway?
Bayne, C G
1997-10-01
Some 13% to 62% of all injuries reported to hospital occupational health workers are traceable to phlebotomy procedures. However, the selection of a needleless system is complex. The informed manager seeks answers to the following questions: (1) Do needleless systems reduce the risk of seroconversion to bloodborne pathogens? (Answer yes.) (2) Does the use of a needleless system affect patients' risk of catheter sepsis? (Answer no.) and (3) What about chemical compatibility with the newer materials used in needleless systems? (New variables require more studies.) The author lists references, manufacturers and some of the chemicals to which some manufacturers have exposed their devices.
dos Santos, Ana Paula Milla; Fracasso, Carla Magioni; Luciene dos Santos, Mirley; Romero, Rosana; Sazima, Marlies; Oliveira, Paulo Eugênio
2012-01-01
Background and Aims Apomictic plants are less dependent on pollinator services and able to occupy more diverse habitats than sexual species. However, such assumptions are based on temperate species, and comparable evaluation for species-rich Neotropical taxa is lacking. In this context, the Melastomataceae is a predominantly Neotropical angiosperm family with many apomictic species, which is common in the Campos Rupestres, endemism-rich vegetation on rocky outcrops in central Brazil. In this study, the breeding system of some Campo Rupestre Melastomataceae was evaluated, and breeding system studies for New World species were surveyed to test the hypothesis that apomixis is associated with wide distributions, whilst sexual species have more restricted areas. Methods The breeding systems of 20 Campo Rupestre Melastomataceae were studied using hand pollinations and pollen-tube growth analysis. In addition, breeding system information was compiled for 124 New World species of Melastomataceae with either wide (>1000 km) or restricted distributions. Key Results Most (80 %) of the Campo Rupestre species studied were self-compatible. Self-incompatibility in Microlicia viminalis was associated with pollen-tube arrest in the style, as described for other Melastomataceae, but most self-incompatible species analysed showed pollen-tube growth to the ovary irrespective of pollination treatment. Apomictic species showed lower pollen viability and were less frequent among the Campo Rupestre plants. Among the New World species compiled, 43 were apomictic and 77 sexual (24 self-incompatible and 53 self-compatible). Most apomictic (86 %) and self-incompatible species (71 %) presented wide distributions, whilst restricted distributions predominate only among the self-compatible ones (53 %). Conclusions Self-compatibility and dependence on biotic pollination were characteristic of Campo Rupestre and narrowly distributed New World Melastomataceae species, whilst apomictics are widely distributed. This is, to a certain extent, similar to the geographical parthenogenesis pattern of temperate apomictics. PMID:22751617
Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes
NASA Technical Reports Server (NTRS)
Thomas, V. L.
1973-01-01
The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.
Advanced Reconnaissance System Component Reliability Study
1956-07-31
dielectrics. Gaseous dielectrics such as sulphur hexafluoride and ’ fluorocarbons at two to three atmospheres. Fluorinated liquid dielectrics. 3) The...limits. (2) determine compatibility with varnish treatments, (3) compatibility in a complete insulation system. Mechanical and thermal limits of...of a varnish to have good • adhersion, provide an element of flexibility and be chemically compatible with’the wire it is impregnating.. Factors of
76 FR 42164 - Announcement of Competition Under the America COMPETES Reauthorization Act of 2011
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-18
... listing will be in a format completely compatible with Microsoft Excel 2007 and contain the information... by VA. The narrative will be in a format completely compatible with Microsoft Word 2007, not...
Using TARGET Data | Office of Cancer Genomics
- ANNOUNCEMENT - The TARGET data matrix will not function properly in Internet Explorer unless the Compatibility View is completely turned off. Visit the How to use Compatibility View in Internet Explorer 9 on the Microsoft Support website for more information. ........................
Morgantown People Mover Electromagnetic Compatibility Program
DOT National Transportation Integrated Search
1980-09-01
Electromagnetic Compatibility (EMC) of a transit system is the absence of interference between all parts of the system, and between the system and the community which it serves. This report documents the EMC experience obtained during the design and ...
Algebraic and geometric structures of analytic partial differential equations
NASA Astrophysics Data System (ADS)
Kaptsov, O. V.
2016-11-01
We study the problem of the compatibility of nonlinear partial differential equations. We introduce the algebra of convergent power series, the module of derivations of this algebra, and the module of Pfaffian forms. Systems of differential equations are given by power series in the space of infinite jets. We develop a technique for studying the compatibility of differential systems analogous to the Gröbner bases. Using certain assumptions, we prove that compatible systems generate infinite manifolds.
Elbes, Delphine; Magat, Julie; Govari, Assaf; Ephrath, Yaron; Vieillot, Delphine; Beeckler, Christopher; Weerasooriya, Rukshen; Jais, Pierre; Quesson, Bruno
2017-03-01
Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Research Needs for Human Factors
1983-01-01
their relative merits. Until such comparisons are made, practitioners will continue to advocate their own products without a basis for choice among ...judgments among a group of experts; (2) formulating questions for "experts in a way that is compatible with their mental structures or "cognitive...system* Typically the operators work in teams and control compute3, which in turn mediate information flow among various automatic components. Other
Electromagnetic Compatibility in the Defense Systems of Future Years
2002-06-01
Technology activities. Its mission is to conduct and promote cooperative research and information exchange . The objective is to support the development...testing CLEARANCE PRODUCTION AND IN-SERVICE SUPPORT Modelling in support of conceptual design (structure & installation design) EMH Design guides for the... marketed by Advanced Electromagnetics [6-1]. Transmission Line Matrix Method The link between field theory and circuit theory, the major theories on
System requirements for head down and helmet mounted displays in the military avionics environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flynn, M.F.; Kalmanash, M.; Sethna, V.
1996-12-31
The introduction of flat panel display technologies into the military avionics cockpit is a challenging proposition, due to the very difficult system level requirements which must be met. These relate to environmental extremes (temperature and vibrational), sever ambient lighting conditions (10,000 fL to nighttime viewing), night vision system compatibility, and wide viewing angle. At the same time, the display system must be packaged in minimal space and use minimal power. The authors will present details on the display system requirements for both head down and helmet mounted systems, as well as information on how these challenges may be overcome.
An Efficient, Scalable and Robust P2P Overlay for Autonomic Communication
NASA Astrophysics Data System (ADS)
Li, Deng; Liu, Hui; Vasilakos, Athanasios
The term Autonomic Communication (AC) refers to self-managing systems which are capable of supporting self-configuration, self-healing and self-optimization. However, information reflection and collection, lack of centralized control, non-cooperation and so on are just some of the challenges within AC systems. Since many self-* properties (e.g. selfconfiguration, self-optimization, self-healing, and self-protecting) are achieved by a group of autonomous entities that coordinate in a peer-to-peer (P2P) fashion, it has opened the door to migrating research techniques from P2P systems. P2P's meaning can be better understood with a set of key characteristics similar to AC: Decentralized organization, Self-organizing nature (i.e. adaptability), Resource sharing and aggregation, and Fault-tolerance. However, not all P2P systems are compatible with AC. Unstructured systems are designed more specifically than structured systems for the heterogeneous Internet environment, where the nodes' persistence and availability are not guaranteed. Motivated by the challenges in AC and based on comprehensive analysis of popular P2P applications, three correlative standards for evaluating the compatibility of a P2P system with AC are presented in this chapter. According to these standards, a novel Efficient, Scalable and Robust (ESR) P2P overlay is proposed. Differing from current structured and unstructured, or meshed and tree-like P2P overlay, the ESR is a whole new three dimensional structure to improve the efficiency of routing, while information exchanges take in immediate neighbors with local information to make the system scalable and fault-tolerant. Furthermore, rather than a complex game theory or incentive mechanism, asimple but effective punish mechanism has been presented based on a new ID structure which can guarantee the continuity of each node's record in order to discourage negative behavior on an autonomous environment as AC.
Guide for Oxygen Compatibility Assessments on Oxygen Components and Systems
NASA Technical Reports Server (NTRS)
Rosales, Keisa R.; Shoffstall, Michael S.; Stoltzfus, Joel M.
2007-01-01
Understanding and preventing fire hazards is necessary when designing, maintaining, and operating oxygen systems. Ignition risks can be minimized by controlling heat sources and using materials that will not ignite or will not support burning in the end-use environment. Because certain materials are more susceptible to ignition in oxygen-enriched environments, a compatibility assessment should be performed before the component is introduced into an oxygen system. This document provides an overview of oxygen fire hazards and procedures that are consistent with the latest versions of American Society for Testing and Materials (ASTM) Standards G63 (1999) and G94 (2005) to address fire hazards associated with oxygen systems. This document supersedes the previous edition, NASA Technical Memorandum 104823, Guide for Oxygen Hazards Analyses on Components and Systems (1996). The step-by-step oxygen compatibility assessment method described herein (see Section 4) enables oxygen-system designers, system engineers, and facility managers to determine areas of concern with respect to oxygen compatibility and, ultimately, prevent damage to a system or injury to personnel.
Bryan, Glenn J.; McLean, Karen; Waugh, Robbie; Spooner, David M.
2017-01-01
DNA-based marker analysis of plant genebank material has become a useful tool in the evaluation of levels of genetic diversity and for the informed use and maintenance of germplasm. In this study, we quantify levels of amplified fragment length polymorphism (AFLP) in representative accessions of wild and cultivated potato species of differing geographic origin, ploidy, and breeding system. We generated 449 polymorphic AFLP fragments in 619 plants, representing multiple plants (16–23) from 17 accessions of 14 potato taxa as well as single plants sampled from available accessions (from 3 to 56) of the same 14 taxa. Intra-accession diversities were compared to those of a synthetic ‘taxon-wide’ population comprising a single individual from a variable number of available accessions of each sampled taxon. Results confirm the expected considerably lower levels of polymorphism within accessions of self-compatible as compared to self-incompatible taxa. We observed broadly similar levels of ‘taxon-wide’ polymorphism among self-compatible and self-incompatible species, with self-compatible taxa showing only slightly lower rates of polymorphism. The most diverse accessions were the two cultivated potato accessions examined, the least diverse being the Mexican allohexaploids Solanum demissum and S. iopetalum. Generally allopolyploid self-compatible accessions exhibited lower levels of diversity. Some purported self-incompatible accessions showed relatively low levels of marker diversity, similar to the more diverse self-compatible material surveyed. Our data indicate that for self-compatible species a single plant is highly representative of a genebank accession. The situation for self-incompatible taxa is less clear, and sampling strategies used will depend on the type of investigation. These results have important implications for those seeking novel trait variation (e.g., disease resistance) in gene banks as well as for the selection of individuals for genomics studies. We also show that AFLPs, despite having been largely replaced by other marker types, is highly suitable for the evaluation of within and between accession diversity in genebanks. PMID:28983315
The Rules of Variation Expanded, Implications for the Research on Compatible Genomics.
Castro-Chavez, Fernando
2011-05-12
The main focus of this article is to present the practical aspect of the code rules of variation and the search for a second set of genomic rules, including comparison of sequences to understand how to preserve compatible organisms in danger of extinction and how to generate biodiversity. Three new rules of variation are introduced: 1) homologous recombination, 2) a healthy fertile offspring, and 3) comparison of compatible genomes. The novel search in the natural world for fully compatible genomes capable of homologous recombination is explored by using examples of human polymorphisms in the LDLRAP1 gene, and by the production of fertile offspring by crossbreeding. Examples of dogs, llamas and finches will be presented by a rational control of: natural crossbreeding of organisms with compatible genomes (something already happening in nature), the current work focuses on the generation of new varieties after a careful plan. This study is presented within the context of biosemiotics, which studies the processing of information, signaling and signs by living systems. I define a group of organisms having compatible genomes as a single theme: the genomic species or population, able to speak the same molecular language through different accents, with each variety within a theme being a different version of the same book. These studies have a molecular, compatible genetics context. Population and ecosystem biosemiotics will be exemplified by a possible genetic damage capable of causing mutations by breaking the rules of variation through the coordinated patterns of atoms present in the 9/11 World Trade Center contaminated dust (U, Ba, La, Ce, Sr, Rb, K, Mn, Mg, etc.), combination that may be able to overload the molecular quality control mechanisms of the human body. I introduce here the balance of codons in the circular genetic code: 2[1(1)+1(3)+1(4)+4(2)]=2[2(2)+3(4)].
The Rules of Variation Expanded, Implications for the Research on Compatible Genomics
Castro-Chavez, Fernando
2011-01-01
The main focus of this article is to present the practical aspect of the code rules of variation and the search for a second set of genomic rules, including comparison of sequences to understand how to preserve compatible organisms in danger of extinction and how to generate biodiversity. Three new rules of variation are introduced: 1) homologous recombination, 2) a healthy fertile offspring, and 3) comparison of compatible genomes. The novel search in the natural world for fully compatible genomes capable of homologous recombination is explored by using examples of human polymorphisms in the LDLRAP1 gene, and by the production of fertile offspring by crossbreeding. Examples of dogs, llamas and finches will be presented by a rational control of: natural crossbreeding of organisms with compatible genomes (something already happening in nature), the current work focuses on the generation of new varieties after a careful plan. This study is presented within the context of biosemiotics, which studies the processing of information, signaling and signs by living systems. I define a group of organisms having compatible genomes as a single theme: the genomic species or population, able to speak the same molecular language through different accents, with each variety within a theme being a different version of the same book. These studies have a molecular, compatible genetics context. Population and ecosystem biosemiotics will be exemplified by a possible genetic damage capable of causing mutations by breaking the rules of variation through the coordinated patterns of atoms present in the 9/11 World Trade Center contaminated dust (U, Ba, La, Ce, Sr, Rb, K, Mn, Mg, etc.), combination that may be able to overload the molecular quality control mechanisms of the human body. I introduce here the balance of codons in the circular genetic code: 2[1(1)+1(3)+1(4)+4(2)]=2[2(2)+3(4)]. PMID:21743816
Space-Based Information Infrastructure Architecture for Broadband Services
NASA Technical Reports Server (NTRS)
Price, Kent M.; Inukai, Tom; Razdan, Rajendev; Lazeav, Yvonne M.
1996-01-01
This study addressed four tasks: (1) identify satellite-addressable information infrastructure markets; (2) perform network analysis for space-based information infrastructure; (3) develop conceptual architectures; and (4) economic assessment of architectures. The report concludes that satellites will have a major role in the national and global information infrastructure, requiring seamless integration between terrestrial and satellite networks. The proposed LEO, MEO, and GEO satellite systems have satellite characteristics that vary widely. They include delay, delay variations, poorer link quality and beam/satellite handover. The barriers against seamless interoperability between satellite and terrestrial networks are discussed. These barriers are the lack of compatible parameters, standards and protocols, which are presently being evaluated and reduced.
Identifying Barriers in the Use of Electronic Health Records in Hawai‘i
Hamamura, Faith D; Hughes, Kira
2017-01-01
Hawai‘i faces unique challenges to Electronic Health Record (EHR) adoption due to physician shortages, a widespread distribution of Medically Underserved Areas and Populations (MUA/P), and a higher percentage of small independent practices. However, research on EHR adoption in Hawai‘i is limited. To address this gap, this article examines the current state of EHR in Hawai‘i, the barriers to adoption, and the future of Health Information Technology (HIT) initiatives to improve the health of Hawai‘i's people. Eight focus groups were conducted on Lana‘i, Maui, Hawai‘i Island, Kaua‘i, Moloka‘i, and O‘ahu. In these groups, a total of 51 diverse health professionals were asked about the functionality of EHR systems, barriers to use, facilitators of use, and what EHRs would look like in a perfect world. Responses were summarized and analyzed based on constant comparative analysis techniques. Responses were then clustered into thirteen themes: system compatibility, loss of productivity, poor interface, IT support, hardware/software, patient factors, education/training, noise in the system, safety, data quality concerns, quality metrics, workflow, and malpractice concerns. Results show that every group mentioned system compatibility. In response to these findings, the Health eNet Community Health Record initiative — which allows providers web-based access to patient health information from the patient's provider network— was developed as a step toward alleviating some of the barriers to sharing information between different EHRs. The Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) legislation will introduce a new payment model in 2017 that is partially based on EHR utilization. Therefore, more research should be done to understand EHR adoption and how this ruling will affect providers in Hawai‘i. PMID:28435756
Identifying Barriers in the Use of Electronic Health Records in Hawai'i.
Hamamura, Faith D; Withy, Kelley; Hughes, Kira
2017-03-01
Hawai'i faces unique challenges to Electronic Health Record (EHR) adoption due to physician shortages, a widespread distribution of Medically Underserved Areas and Populations (MUA/P), and a higher percentage of small independent practices. However, research on EHR adoption in Hawai'i is limited. To address this gap, this article examines the current state of EHR in Hawai'i, the barriers to adoption, and the future of Health Information Technology (HIT) initiatives to improve the health of Hawai'i's people. Eight focus groups were conducted on Lana'i, Maui, Hawai'i Island, Kaua'i, Moloka'i, and O'ahu. In these groups, a total of 51 diverse health professionals were asked about the functionality of EHR systems, barriers to use, facilitators of use, and what EHRs would look like in a perfect world. Responses were summarized and analyzed based on constant comparative analysis techniques. Responses were then clustered into thirteen themes: system compatibility, loss of productivity, poor interface, IT support, hardware/software, patient factors, education/training, noise in the system, safety, data quality concerns, quality metrics, workflow, and malpractice concerns. Results show that every group mentioned system compatibility. In response to these findings, the Health eNet Community Health Record initiative - which allows providers web-based access to patient health information from the patient's provider network- was developed as a step toward alleviating some of the barriers to sharing information between different EHRs. The Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) legislation will introduce a new payment model in 2017 that is partially based on EHR utilization. Therefore, more research should be done to understand EHR adoption and how this ruling will affect providers in Hawai'i.
Unimodular sequence design under frequency hopping communication compatibility requirements
NASA Astrophysics Data System (ADS)
Ge, Peng; Cui, Guolong; Kong, Lingjiang; Yang, Jianyu
2016-12-01
The integrated design for both radar and anonymous communication has drawn more attention recently since wireless communication system appeals to enhance security and reliability. Given the frequency hopping (FH) communication system, an effective way to realize integrated design is to meet the spectrum compatibility between these two systems. The paper deals with a unimodular sequence design technique which considers optimizing both the spectrum compatibility and peak sidelobes levels (PSL) of auto-correlation function (ACF). The spectrum compatibility requirement realizes anonymous communication for the FH system and provides this system lower probability of intercept (LPI) since the spectrum of the FH system is hidden in that of the radar system. The proposed algorithm, named generalized fitting template (GFT) technique, converts the sequence optimization design problem to a iterative fitting process. In this process, the power spectrum density (PSD) and PSL behaviors of the generated sequences fit both PSD and PSL templates progressively. Two templates are established based on the spectrum compatibility requirement and the expected PSL. As noted, in order to ensure the communication security and reliability, spectrum compatibility requirement is given a higher priority to achieve in the GFT algorithm. This algorithm realizes this point by adjusting the weight adaptively between these two terms during the iteration process. The simulation results are analyzed in terms of bit error rate (BER), PSD, PSL, and signal-interference rate (SIR) for both the radar and FH systems. The performance of GFT is compared with SCAN, CAN, FRE, CYC, and MAT algorithms in the above aspects, which shows its good effectiveness.
Design theory, modelling and the application for the Internet of Things service
NASA Astrophysics Data System (ADS)
Shang, Xiaopu; Zhang, Runtong; Zhu, Xiaomin; Zhou, Quan
2016-03-01
The Internet of Things (IoT) makes it possible for us to sense the physical world and locate objects in it using the enabling technologies associated with IoT. Compared with traditional information systems, IoT enabling technologies can help acquire real-time data necessary for managing enterprise business process. An IoT system should have an ability beyond integrating enabling technologies and traditional information systems that are only used to access environmental data. This paper begins with a literature review of IoT-related issues and a discussion of the difference between traditional information service and IoT service. Three principles for IoT service design from the perceptive of service classification, coordination and compatibility are proposed. The paper also proposes a utility model for resource allocation in order to improve IoT service performance, and an application involving a cold chain visibility platform is given to illustrate our research.
NASA Technical Reports Server (NTRS)
Congo, Richard T.
1990-01-01
As the Space Station nears reality in funding support from Congress, NASA plans to perform over a hundred different missions in the coming decade. Incrementally deployed, the Space Station will evolve into modules linked to an integral structure. Each module will have characteristic functions, such as logistics, habitation, and materials processing. Because the Space Station is to be user friendly for experimenters, NASA is anticipating that a variety of different chemicals will be taken on-board. Accidental release of these potentially toxic chemicals and their chemical compatibility is the focus of this discourse. The Microgravity Manufacturing Processing Facility (MMPF) will contain the various facilities within the U.S. Laboratory (USL). Each facility will have a characteristic purpose, such as alloy solidification or vapor crystal growth. By examining the proposed experiments for each facility, identifying the chemical constituents, their physical state and/or changes, byproducts and effluents, those payloads can be identified which may contain toxic, explosive, or reactive compounds that require processing or containment in mission peculiar waste management systems. Synergistic reactions from mixed effluent streams is of major concern. Each experiment will have it own data file, complete with schematic, chemical listing, physical data, etc. Chemical compatibility information from various databases will provide assistance in the analysis of alternate disposal techniques (pretreatment, separate storage, etc.). Along with data from the Risk Analysis of the Proposed USL Waste Management System, accidental release of potentially toxic and catastrophic chemicals would be eliminated or reduced.
Compatibility of switchgrass as an energy crop in farming systems of the southeastern USA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bransby, D.I.; Rodriguez-Kabana, R.; Sladden, S.E.
1993-12-31
The objective of this paper is to examine the compatibility of switchgrass as an energy crop in farming systems in the southeastern USA, relative to other regions. In particular, the issues addressed are (1) competition between switchgrass as an energy crop and existing farm enterprises, based primarily on economic returns, (2) complementarity between switchgrass and existing farm enterprises, and (3) environmental benefits. Because projected economic returns for switchgrass as an energy crop are highest in the Southeast, and returns from forestry and beef pastures (the major existing enterprises) are low, there is a very strong economic incentive in this region.more » In contrast, based on current information, economic viability of switchgrass as an energy crop in other regions appears doubtful. In addition, switchgrass in the southeastern USA would complement forage-livestock production, row crop production and wildlife and would provide several additional environmental benefits. It is concluded that the southeastern USA offers the greatest opportunity for developing switchgrass as an economically viable energy crop.« less
DOT National Transportation Integrated Search
2018-04-01
The goal of the U.S. Department of Transportation (DOT) Global Positioning System (GPS) Adjacent Band Compatibility Assessment is to evaluate the maximum transmitted power levels of adjacent band radiofrequency (RF) systems that can be tolerated by G...
Strack, Gamze; Kaufmann, Christian; Kehrer, Stefanie; Brandt, Stephan; Stürmer, Birgit
2013-01-01
With the present study we investigated cue-induced preparation in a Simon task and measured electroencephalogram and functional magnetic resonance imaging (fMRI) data in two within-subjects sessions. Cues informed either about the upcoming (1) spatial stimulus-response compatibility (rule cues), or (2) the stimulus location (position cues), or (3) were non-informative. Only rule cues allowed anticipating the upcoming compatibility condition. Position cues allowed anticipation of the upcoming location of the Simon stimulus but not its compatibility condition. Rule cues elicited fastest and most accurate performance for both compatible and incompatible trials. The contingent negative variation (CNV) in the event-related potential (ERP) of the cue-target interval is an index of anticipatory preparation and was magnified after rule cues. The N2 in the post-target ERP as a measure of online action control was reduced in Simon trials after rule cues. Although compatible trials were faster than incompatible trials in all cue conditions only non-informative cues revealed a compatibility effect in additional indicators of Simon task conflict like accuracy and the N2. We thus conclude that rule cues induced anticipatory re-coding of the Simon task that did not involve cognitive conflict anymore. fMRI revealed that rule cues yielded more activation of the left rostral, dorsal, and ventral prefrontal cortex as well as the pre-SMA as compared to POS and NON-cues. Pre-SMA and ventrolateral prefrontal activation after rule cues correlated with the effective use of rule cues in behavioral performance. Position cues induced a smaller CNV effect and exhibited less prefrontal and pre-SMA contributions in fMRI. Our data point to the importance to disentangle different anticipatory adjustments that might also include the prevention of upcoming conflict via task re-coding. PMID:23408377
Gallet, Romain; Fontaine, Colin; Bonnot, François; Milazzo, Joëlle; Tertois, Christophe; Adreit, Henri; Ravigné, Virginie; Fournier, Elisabeth; Tharreau, Didier
2016-04-01
Efficient strategies for limiting the impact of pathogens on crops require a good understanding of the factors underlying the evolution of compatibility range for the pathogens and host plants, i.e., the set of host genotypes that a particular pathogen genotype can infect and the set of pathogen genotypes that can infect a particular host genotype. Until now, little is known about the evolutionary and ecological factors driving compatibility ranges in systems implicating crop plants. We studied the evolution of host and pathogen compatibility ranges for rice blast disease, which is caused by the ascomycete Magnaporthe oryzae. We challenged 61 rice varieties from three rice subspecies with 31 strains of M. oryzae collected worldwide from all major known genetic groups. We determined the compatibility range of each plant variety and pathogen genotype and the severity of each plant-pathogen interaction. Compatibility ranges differed between rice subspecies, with the most resistant subspecies selecting for pathogens with broader compatibility ranges and the least resistant subspecies selecting for pathogens with narrower compatibility ranges. These results are consistent with a nested distribution of R genes between rice subspecies.
Phillips, Joshua; Chilukuri, Ram; Fragoso, Gilberto; Warzel, Denise; Covitz, Peter A
2006-01-06
Robust, programmatically accessible biomedical information services that syntactically and semantically interoperate with other resources are challenging to construct. Such systems require the adoption of common information models, data representations and terminology standards as well as documented application programming interfaces (APIs). The National Cancer Institute (NCI) developed the cancer common ontologic representation environment (caCORE) to provide the infrastructure necessary to achieve interoperability across the systems it develops or sponsors. The caCORE Software Development Kit (SDK) was designed to provide developers both within and outside the NCI with the tools needed to construct such interoperable software systems. The caCORE SDK requires a Unified Modeling Language (UML) tool to begin the development workflow with the construction of a domain information model in the form of a UML Class Diagram. Models are annotated with concepts and definitions from a description logic terminology source using the Semantic Connector component. The annotated model is registered in the Cancer Data Standards Repository (caDSR) using the UML Loader component. System software is automatically generated using the Codegen component, which produces middleware that runs on an application server. The caCORE SDK was initially tested and validated using a seven-class UML model, and has been used to generate the caCORE production system, which includes models with dozens of classes. The deployed system supports access through object-oriented APIs with consistent syntax for retrieval of any type of data object across all classes in the original UML model. The caCORE SDK is currently being used by several development teams, including by participants in the cancer biomedical informatics grid (caBIG) program, to create compatible data services. caBIG compatibility standards are based upon caCORE resources, and thus the caCORE SDK has emerged as a key enabling technology for caBIG. The caCORE SDK substantially lowers the barrier to implementing systems that are syntactically and semantically interoperable by providing workflow and automation tools that standardize and expedite modeling, development, and deployment. It has gained acceptance among developers in the caBIG program, and is expected to provide a common mechanism for creating data service nodes on the data grid that is under development.
NASA-STD-6016 Standard Materials and Processes Requirements for Spacecraft
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2009-01-01
The standards for materials and processes surrounding spacecraft are discussed. Presentation focused on minimum requirements for Materials and Processes (M&P) used in design, fabrication, and testing of flight components for NASA manned, unmanned, robotic, launch vehicle, lander, in-space and surface systems, and spacecraft program/project hardware elements.Included is information on flammability, offgassing, compatibility requirements, and processes; both metallic and non-metallic materials are mentioned.
2006-03-13
the SaaS architecture, not as a set of add-ons and software applications.31 From the equipping perspective, the SaaS consists of the Soldier and all...ensure integration and compatibility within the Army, with other services and, to the extent possible, with U.S. allies. The SaaS ICT also reviews and...including suggestions for reducing this burden, to Washington Headquarters Services , Directorate for Information Operations and Reports, 1215 Jefferson Davis
XML syntax for clinical laboratory procedure manuals.
Saadawi, Gilan; Harrison, James H
2003-01-01
We have developed a document type description (DTD) in Extensable Markup Language (XML) for clinical laboratory procedures. Our XML syntax can adequately structure a variety of procedure types across different laboratories and is compatible with current procedure standards. The combination of this format with an XML content management system and appropriate style sheets will allow efficient procedure maintenance, distributed access, customized display and effective searching across a large body of test information.
NASA Technical Reports Server (NTRS)
Garcia, Jerry L.; McCleskey, Carey M.; Bollo, Timothy R.; Rhodes, Russel E.; Robinson, John W.
2012-01-01
This paper presents a structured approach for achieving a compatible Ground System (GS) and Flight System (FS) architecture that is affordable, productive and sustainable. This paper is an extension of the paper titled "Approach to an Affordable and Productive Space Transportation System" by McCleskey et al. This paper integrates systems engineering concepts and operationally efficient propulsion system concepts into a structured framework for achieving GS and FS compatibility in the mid-term and long-term time frames. It also presents a functional and quantitative relationship for assessing system compatibility called the Architecture Complexity Index (ACI). This paper: (1) focuses on systems engineering fundamentals as it applies to improving GS and FS compatibility; (2) establishes mid-term and long-term spaceport goals; (3) presents an overview of transitioning a spaceport to an airport model; (4) establishes a framework for defining a ground system architecture; (5) presents the ACI concept; (6) demonstrates the approach by presenting a comparison of different GS architectures; and (7) presents a discussion on the benefits of using this approach with a focus on commonality.
Space shuttle main engine definition (phase B). Volume 2: Avionics. [for space shuttle
NASA Technical Reports Server (NTRS)
1971-01-01
The advent of the space shuttle engine with its requirements for high specific impulse, long life, and low cost have dictated a combustion cycle and a closed loop control system to allow the engine components to run close to operating limits. These performance requirements, combined with the necessity for low operational costs, have placed new demands on rocket engine control, system checkout, and diagnosis technology. Based on considerations of precision environment, and compatibility with vehicle interface commands, an electronic control, makes available many functions that logically provide the information required for engine system checkout and diagnosis.
14 CFR 150.23 - Noise compatibility programs.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Development of Noise Exposure Maps and Noise... consultation with FAA regional officials, the officials of the state and of any public agencies and planning..., informal agreement from FAA on proposed new or modified flight procedures. For air carrier airports...
14 CFR 150.23 - Noise compatibility programs.
Code of Federal Regulations, 2013 CFR
2013-01-01
... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Development of Noise Exposure Maps and Noise... consultation with FAA regional officials, the officials of the state and of any public agencies and planning..., informal agreement from FAA on proposed new or modified flight procedures. For air carrier airports...
14 CFR 150.23 - Noise compatibility programs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Development of Noise Exposure Maps and Noise... consultation with FAA regional officials, the officials of the state and of any public agencies and planning..., informal agreement from FAA on proposed new or modified flight procedures. For air carrier airports...
14 CFR 150.23 - Noise compatibility programs.
Code of Federal Regulations, 2012 CFR
2012-01-01
... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Development of Noise Exposure Maps and Noise... consultation with FAA regional officials, the officials of the state and of any public agencies and planning..., informal agreement from FAA on proposed new or modified flight procedures. For air carrier airports...
14 CFR 150.23 - Noise compatibility programs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (CONTINUED) AIRPORTS AIRPORT NOISE COMPATIBILITY PLANNING Development of Noise Exposure Maps and Noise... consultation with FAA regional officials, the officials of the state and of any public agencies and planning..., informal agreement from FAA on proposed new or modified flight procedures. For air carrier airports...
47 CFR 76.630 - Compatibility with consumer electronics equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...
47 CFR 76.630 - Compatibility with consumer electronics equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 4 2011-10-01 2011-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...
47 CFR 76.630 - Compatibility with consumer electronics equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...
47 CFR 76.630 - Compatibility with consumer electronics equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 4 2013-10-01 2013-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...
47 CFR 76.630 - Compatibility with consumer electronics equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...
47 CFR 76.1621 - Equipment compatibility offer.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment compatibility offer. 76.1621 Section 76.1621 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system...
47 CFR 76.1621 - Equipment compatibility offer.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 4 2013-10-01 2013-10-01 false Equipment compatibility offer. 76.1621 Section 76.1621 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system...
47 CFR 76.1621 - Equipment compatibility offer.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Equipment compatibility offer. 76.1621 Section 76.1621 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system...
47 CFR 76.1621 - Equipment compatibility offer.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 4 2011-10-01 2011-10-01 false Equipment compatibility offer. 76.1621 Section 76.1621 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system...
47 CFR 76.1621 - Equipment compatibility offer.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Equipment compatibility offer. 76.1621 Section 76.1621 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system...
14 CFR 25.941 - Inlet, engine, and exhaust compatibility.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., engine, and exhaust compatibility. For airplanes using variable inlet or exhaust system geometry, or both— (a) The system comprised of the inlet, engine (including thrust augmentation systems, if incorporated... configurations; (b) The dynamic effects of the operation of these (including consideration of probable...
Prevalence of information stored in arrays of magnetic nanowires against external fields
NASA Astrophysics Data System (ADS)
Ceballos, D.; Cisternas, E.; Vogel, E. E.; Allende, S.
2018-04-01
Arrays of magnetic nanowires in porous alumina can be used to store information inscribed on the system by orienting the magnetization of selected wires pointing in a desired direction, so symbols can be read as ferromagnetic sectors. However, this information is subject to aging and the stored information could be gradually lost. We investigate here two mechanisms proposed to improve the prevalence of the stored information: opposite ferromagnetic band at the center of the symbol and bi-segmented nanowires acting as two layers of nanowires storing the same information. Both mechanisms prove to increase resistance to the action of external magnetic fields for the case of Ni wires in a geometry compatible with actually grown nanowires. Advantages and disadvantages of these mechanisms are discussed.
Forest Resource Information System (FRIS)
NASA Technical Reports Server (NTRS)
1983-01-01
The technological and economical feasibility of using multispectral digital image data as acquired from the LANDSAT satellites in an ongoing operational forest information system was evaluated. Computer compatible multispectral scanner data secured from the LANDSAT satellites were demonstrated to be a significant contributor to ongoing information systems by providing the added dimensions of synoptic and repeat coverage of the Earth's surface. Major forest cover types of conifer, deciduous, mixed conifer-deciduous and non-forest, were classified well within the bounds of the statistical accuracy of the ground sample. Further, when overlayed with existing maps, the acreage of cover type retains a high level of positional integrity. Maps were digitized by a graphics design system, overlayed and registered onto LANDSAT imagery such that the map data with associated attributes were displayed on the image. Once classified, the analysis results were converted back to map form as a cover type of information. Existing tabular information as represented by inventory is registered geographically to the map base through a vendor provided data management system. The notion of a geographical reference base (map) providing the framework to which imagery and tabular data bases are registered and where each of the three functions of imagery, maps and inventory can be accessed singly or in combination is the very essence of the forest resource information system design.
Compatibility of motion facilitates visuomotor synchronization.
Hove, Michael J; Spivey, Michael J; Krumhansl, Carol L
2010-12-01
Prior research indicates that synchronized tapping performance is very poor with flashing visual stimuli compared with auditory stimuli. Three finger-tapping experiments compared flashing visual metronomes with visual metronomes containing a spatial component, either compatible, incompatible, or orthogonal to the tapping action. In Experiment 1, synchronization success rates increased dramatically for spatiotemporal sequences of both geometric and biological forms over flashing sequences. In Experiment 2, synchronization performance was best when target sequences and movements were directionally compatible (i.e., simultaneously down), followed by orthogonal stimuli, and was poorest for incompatible moving stimuli and flashing stimuli. In Experiment 3, synchronization performance was best with auditory sequences, followed by compatible moving stimuli, and was worst for flashing and fading stimuli. Results indicate that visuomotor synchronization improves dramatically with compatible spatial information. However, an auditory advantage in sensorimotor synchronization persists.
Program Helps Generate And Manage Graphics
NASA Technical Reports Server (NTRS)
Truong, L. V.
1994-01-01
Living Color Frame Maker (LCFM) computer program generates computer-graphics frames. Graphical frames saved as text files, in readable and disclosed format, easily retrieved and manipulated by user programs for wide range of real-time visual information applications. LCFM implemented in frame-based expert system for visual aids in management of systems. Monitoring, diagnosis, and/or control, diagrams of circuits or systems brought to "life" by use of designated video colors and intensities to symbolize status of hardware components (via real-time feedback from sensors). Status of systems can be displayed. Written in C++ using Borland C++ 2.0 compiler for IBM PC-series computers and compatible computers running MS-DOS.
Theiss, Kathryn E; Holsinger, Kent E; Evans, Margaret E K
2010-06-01
We examined two accounts of the relationship between breeding system and life history variation in a clade of evening primroses (Oenothera, Onagraceae): (1) selection for reproductive assurance should generate an association between self-compatibility and monocarpy and (2) phylogenetic conservatism leads to retention of breeding system and life history traits among closely related taxa. • We performed over 4000 hand pollinations under greenhouse conditions to determine the compatibility of 10 Oenothera taxa (sections Anogra [17 taxa] and Kleinia [2 taxa)] for which breeding systems had not previously been reported. We used generalized linear mixed models to evaluate the influence of pollination treatment, parents, and population on fruiting success. • Among the taxa tested, six were self-incompatible, two were variable in compatibility, and two were self-compatible. We combined these data with published studies in Anogra and Kleinia and mapped breeding system and life history onto a published phylogeny. • We found no evidence for phylogenetic conservatism, but detected considerable evolutionary lability in both traits. Additionally, we found no evidence for a consistent relationship between breeding system and life history. Only eight of 19 taxa followed the predicted association between self-incompatibility and polycarpy vs. self-compatibility and monocarpy. Instead, many taxa have retained self-incompatibility, regardless of monocarpy or polycarpy.
Skylab Rescue Space Vehicle OAT No. 1 Plugs in Test
NASA Technical Reports Server (NTRS)
Jevitt, S. J.
1973-01-01
A test is described which demonstrates the compatibility of the Skylab Rescue Space Vehicle systems, the ground support equipment, and off-site support facilities by proceeding through a simulated launch countdown, liftoff, and flight. The functions of propellant loading, umbilical ejection, holddown arm release, service arm retraction, liftoff, and inflight separation are simulated. An external power source supplies transfer power to internal, and instrument unit commands are simulated by the digital command system. The test outline is presented along with a list of references, intercommunications information, radio frequency matrix, and interface control chart.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-26
... of display screens, wireless headsets, and simultaneous transmission capabilities in handsets. The... Communications Commission. ACTION: Proposed rule. SUMMARY: In this document, the Wireless Telecommunications... relating to hearing aid compatibility of wireless handsets. The Bureau seeks updated comment on whether, in...
76 FR 77747 - Amendment of the Commission's Rules Governing Hearing Aid-Compatible Mobile Handsets
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-14
... revisions to the Commission's wireless hearing aid compatibility rules. The Commission's rules define... digital wireless handsets. The proposed rules would adopt the revised version of the technical standard.... FOR FURTHER INFORMATION CONTACT: Michael Rowan, Wireless Telecommunications Bureau, (202) 418-1883...
75 FR 54546 - Amendment of the Commission's Rules Governing Hearing Aid-Compatible Mobile Handsets
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-08
... revisions to the Commission's wireless hearing aid compatibility rules. The Commission initiates this proceeding to ensure that consumers with hearing loss are able to access wireless communications services.... FOR FURTHER INFORMATION CONTACT: John Borkowski, Wireless Telecommunications Bureau, (202) 418-0626, e...
Readout Strategy of an Electro-optical Coupled PET Detector for Time-of-Flight PET/MRI
Bieniosek, M F; Olcott, P D; Levin, C S
2013-01-01
Combining PET with MRI in a single system provides clinicians with complementary molecular and anatomical information. However, existing integrated PET/MRI systems do not have time-of-flight PET capabilities. This work describes an MRI-compatible front-end electronic system with ToF capabilities. The approach employs a fast arrival-time pickoff comparator to digitize the timing information, and a laser diode to drive a 10m fiber-optic cable to optically transmit asynchronous timing information to a photodiode receiver readout system. The comparator and this electo-optical link show a combined 11.5ps fwhm jitter in response to a fast digital pulse. When configured with LYSO scintillation crystals and Hamamatsu MPPC silicon photo-multipliers the comparator and electro-optical link achieved a 511keV coincidence time resolution of 254.7ps +/− 8.0ps fwhm with 3×3×20mm crystals and 166.5 +/− 2.5ps fwhm with 3×3×5mm crystals. PMID:24061218
New advances in MR-compatible bioartificial liver
Jeffries, Rex E.; Macdonald, Jeffrey M.
2015-01-01
MR-compatible bioartificial liver (BAL) studies have been performed for 30 years and are reviewed. There are two types of study: (i) metabolism and drug studies using multinuclear MRS; primarily short-term (< 8 h) studies; (ii) the use of multinuclear MRS and MRI to noninvasively define the features and functions of BAL systems for long-term liver tissue engineering. In the latter, these systems often undergo not only modification of the perfusion system, but also the construction of MR radiofrequency probes around the bioreactor. We present novel MR-compatible BALs and the use of multinuclear MRS (13C, 19F, 31P) for the noninvasive monitoring of their growth, metabolism and viability, as well as 1H MRI methods for the determination of flow profiles, diffusion, cell distribution, quality assurance and bioreactor integrity. Finally, a simple flexible coil design and circuit, and life support system, are described that can make almost any BAL MR-compatible. PMID:22351642
NASA Astrophysics Data System (ADS)
Hoskins, Douglas; Snead, Robert
1988-05-01
This report details the results of an electromagnetic compatibility test on the SCI Systems Data Acquisition and Control Assembly (DACA). This assembly is an electronic processor which controls the central communication link from the Tethered Satellite System (TSS) to the Space Transportation System Orbiter Space Shuttle.
Flight crew aiding for recovery from subsystem failures
NASA Technical Reports Server (NTRS)
Hudlicka, E.; Corker, K.; Schudy, R.; Baron, Sheldon
1990-01-01
Some of the conceptual issues associated with pilot aiding systems are discussed and an implementation of one component of such an aiding system is described. It is essential that the format and content of the information the aiding system presents to the crew be compatible with the crew's mental models of the task. It is proposed that in order to cooperate effectively, both the aiding system and the flight crew should have consistent information processing models, especially at the point of interface. A general information processing strategy, developed by Rasmussen, was selected to serve as the bridge between the human and aiding system's information processes. The development and implementation of a model-based situation assessment and response generation system for commercial transport aircraft are described. The current implementation is a prototype which concentrates on engine and control surface failure situations and consequent flight emergencies. The aiding system, termed Recovery Recommendation System (RECORS), uses a causal model of the relevant subset of the flight domain to simulate the effects of these failures and to generate appropriate responses, given the current aircraft state and the constraints of the current flight phase. Since detailed information about the aircraft state may not always be available, the model represents the domain at varying levels of abstraction and uses the less detailed abstraction levels to make inferences when exact information is not available. The structure of this model is described in detail.
78 FR 64213 - Information Collection Being Reviewed by the Federal Communications Commission
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-28
....1621, Equipment Compatibility Offer; Section 76.1622, Consumer Education of Equipment Compatibility... Commission, Media Bureau, Washington, DC 20554, and should include the name of the cable operator to whom the... on encryption of the basic service tier. This rule change allows all- digital cable operators to...
Office of Economic Adjustment | U.S. Department of Defense
Reuse Compatible Use Defense Contractor Transitions Federal Assistance Coordination Mission Change contractor or manufacturer is making cuts or closing. Explore BRAC Icon Base Realignment and Closure A contact information. What We Do Base Closure Base Realignment Base Reuse Compatible Use Defense Contractor
Compatibility of Army Systems with Anthropometric Characteristics of Female Soldiers
1997-09-01
M, Industrial Security Manual, Section 11-19 or DoD 5200.1-R, Information Security Program Regulation, Chapter IX. For Unclassified/ Limited ...of female soldiers. Participation was limited to female soldiers whose height did not exceed 5’ 5", the 5th percentile value of male soldiers’ height...CLASSIFICATION tffcMSSIFIED 18. SECURITY CLASSIFICATION uffdLÄS^FIED 19. SECURITY CLASSIFICATION ST*—FIED 20. LIMITATION OF ABSTRACT SAR
Skylab rescue space vehicle flight readiness test
NASA Technical Reports Server (NTRS)
Jevitt, S. J.
1973-01-01
A Skylab Rescue Space Vehicle flight readiness test is described which ensures that space vehicle systems are in a state of flight readiness and are compatible with associated ground support equipment. The functions of propellant loading, umbilical ejection, ignition, holddown arm release, liftoff, and service arm and tail service mast retraction are simulated. The test outline is presented along with a list of references, intercommunications information, operations interface control chart, and flight test.
NASA Astrophysics Data System (ADS)
Siontorou, Christina G.
2012-12-01
Biosensors are analytic devices that incorporate a biochemical recognition system (biological, biologicalderived or biomimic: enzyme, antibody, DNA, receptor, etc.) in close contact with a physicochemical transducer (electrochemical, optical, piezoelectric, conductimetric, etc.) that converts the biochemical information, produced by the specific biological recognition reaction (analyte-biomolecule binding), into a chemical or physical output signal, related to the concentration of the analyte in the measuring sample. The biosensing concept is based on natural chemoreception mechanisms, which are feasible over/within/by means of a biological membrane, i.e., a structured lipid bilayer, incorporating or attached to proteinaceous moieties that regulate molecular recognition events which trigger ion flux changes (facilitated or passive) through the bilayer. The creation of functional structures that are similar to natural signal transduction systems, correlating and interrelating compatibly and successfully the physicochemical transducer with the lipid film that is self-assembled on its surface while embedding the reconstituted biological recognition system, and at the same time manage to satisfy the basic conditions for measuring device development (simplicity, easy handling, ease of fabrication) is far from trivial. The aim of the present work is to present a methodological framework for designing such molecular sensing interfaces, functioning within a knowledge-based system built on an ontological platform for supplying sub-systems options, compatibilities, and optimization parameters.
ARTI refrigerant database. Quarterly report, March--May 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calm, J.M.
1997-05-01
The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information an older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some maymore » be added at a later date.« less
Unification: An international aerospace information issue
NASA Technical Reports Server (NTRS)
Cotter, Gladys A.; Lahr, Thomas F.
1991-01-01
Science and technology projects are becoming more and more international and interdisciplinary. Other parts of the world, notably Europe, are increasingly powerful players in the aerospace business. This change has led to the development of various aerospace information initiatives in other countries. With scarce resources in all areas of government and industry, the NASA STI Program is reviewing its current acquisition and exchange practices and policies to factor in the changing requirements and new opportunities within the international community. Current NASA goals and activities are reviewed with a view toward developing a scenario for establishing an international aerospace data base, maintaining compatibility among national aerospace information systems, eliminating duplication of effort, and sharing resources through international cooperation wherever possible.
Unification - An international aerospace information opportunity
NASA Technical Reports Server (NTRS)
Cotter, Gladys A.; Lahr, Thomas F.
1992-01-01
Science and technology projects are becoming more and more international and interdisciplinary. Other parts of the world, notably Europe, are increasingly powerful players in the aerospace industry. This change has led to the development of various aerospace information initiatives in other countries. With scarce resources in all areas of government and industry, the NASA STI Program is reviewing its current acquisition and exchange practices and policies to factor in the changing requirements and new opportunities within the international community. Current NASA goals and activities are reviewed with a new view toward developing a scenario for establishing an international aerospace database, maintaining compatibility among national aerospace information systems, eliminating duplication of effort, and sharing resources through international cooperation wherever possible.
Unification: An international aerospace information opportunity
NASA Technical Reports Server (NTRS)
Cotter, Gladys A.; Lahr, Thomas F.; Carroll, Bonnie C.
1992-01-01
Science and technology projects are becoming more and more international and interdisciplinary. Other parts of the world, notably Europe, are increasingly powerful players in the aerospace industry. This change has led to the development of various aerospace information initiatives in other countries. With scarce resources in all areas of government and industry, the NASA STI Program is reviewing its current acquisition and exchange practices and policies to factor in the changing requirements and new opportunities within the international community. Current NASA goals and activities are reviewed with a new view toward developing a scenario for establishing an international aerospace database, maintaining compatibility among national aerospace information systems, eliminating duplication of effort, and sharing resources through international cooperation wherever possible.
Eat Me If You Can: Cognitive Mechanisms Underlying the Distance Effect
Junghans, Astrid F.; Evers, Catharine; De Ridder, Denise T. D.
2013-01-01
Proximal objects provide affordances that activate the motor information involved in interacting with the objects. This effect has previously been shown for artifacts but not for natural objects, such as food. This study examined whether the sight of proximal food, compared to distant food activates eating-related information. In two experiments reaction times to verbal labels following the sight of proximal and distant objects (food and toys) were measured. Verbal labels included function words that were compatible with one object category (eating and playing) and observation words compatible with both object categories. The sight of food was expected to activate eating-related information when presented at proximity but not at distance, as reflected by faster reaction times to proximal than distant compatible eating words and no difference between reaction times to proximal and distant food for observation words (Experiment 1). Experiment 2 additionally compared the reaction times to wrapped and unwrapped food. The distance effect was expected to occur only for unwrapped food because only unwrapped food is readily edible. As expected, Experiment 1 and 2 revealed faster responses to compatible eating words at proximity than at distance. In Experiment 2 this distance effect occurred only for readily edible, unwrapped food but not for wrapped food. For observation words no difference in response times between the distances was found. These findings suggest that the sight of proximal food activates eating-related information, which could explain people’s differential behavioral responses to reachable versus distant food. The activation of eating-related information upon sight of accessible food could provide a cognition-based explanation for mindless eating. PMID:24367684
Weapon and Sighting System Compatibility Assessment for Prototype Maxillofacial Protection Devices
2013-03-01
No Maxillofacial Protection, No Visor (figure 38) ...........................22 7.2 Sighting System Compatibility – Bradley Fighting Vehicle ( BFV ...23 Figure 39. FASTBAC, bracket only ( BFV ...23 Figure 40. FASTBAC bracket and maxillofacial protection ( BFV ). ............................................24 Figure 41. FIREBALL
Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems
NASA Astrophysics Data System (ADS)
Tsaliovich, Anatoly
Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.
Implementation of safety driving system using e-health and telematics technology.
Lee, Youngbum; Lee, Myoungho
2008-08-01
This research aimed to develop a safety driving system using e-health and telematics technology. Biosignal sensors were installed in an automobile to check the driver's health status with an automatic diagnosis system providing health information to the driver. Measured data were sent to the e-health center through a telematics device, and a medical doctor analyzed these data, sending diagnosis and prescription information to the driver. This system recognizes the driver's sleeping, drinking impairment, excitability, and fatigue using biosensors. The system initially provides alerts in the automobile. It also controls the driving environment in the car, searches for a highway service area using Global Positioning System (GPS), and provides additional information for safety driving. If a car accident has occurred, it makes an emergency call to the nearest hospital, emergency center, and insurance company. A conceptual and prototype model for an imbedded system is presented with initial data for driver condition. Such a system could prevent car accidents caused by drivers driving while intoxicated and falling asleep at the wheel using the driver's biosignals measured by biosensors. The system can provide various e-health services using a telematics system to enhance the technical compatibility of the automobile.
Mishaps with Oxygen in NASA Operations
NASA Technical Reports Server (NTRS)
Ordin, Paul M.
1971-01-01
Data from a substantial number of oxygen mishaps obtained from NASA and contractor records are presented. Information from several Air Force records, concerning oxygen accidents involving aircraft operations, are also included. Descriptions of the mishaps and their causes, for both liquid and gaseous oxygen in ground test facilities and space vehicle systems, are given. A number of safety regulations aimed at reducing the accident probability is discussed. The problems related to material compatibility and materials testing are considered, and the limited information on factors affecting the ignition of materials in oxygen is presented. In addition, details are given of several of the accident/incidents listed in order to define the combination of conditions causing the mishap. In addition to propellant system mishaps, accident/incidents which occurred in space and ground system structures were included, as well as those in electrical systems, ground support facilities, ordnance, and related operations.
A Video Transmission System for Severely Degraded Channels
2006-07-01
rate compatible punctured convolutional codes (RCPC) . By separating the SPIHT bitstream...June 2000. 149 [170] J. Hagenauer, Rate - compatible punctured convolutional codes (RCPC codes ) and their applications, IEEE Transactions on...Farvardin [160] used rate compatible convolutional codes . They noticed that for some transmission rates , one of their EEP schemes, which may
Micro-Macro Compatibility: When Does a Complex Systems Approach Strongly Benefit Science Learning?
ERIC Educational Resources Information Center
Samon, Sigal; Levy, Sharona T.
2017-01-01
The study explores how a complexity approach empowers science learning. A complexity approach represents systems as many interacting entities. The construct of micro-macro compatibility is introduced, the degree of similarity between behaviors at the micro- and macro-levels of the system. Seventh-grade students' learning about gases was studied…
Glynn, P.D.
1991-01-01
The computer code MBSSAS uses two-parameter Margules-type excess-free-energy of mixing equations to calculate thermodynamic equilibrium, pure-phase saturation, and stoichiometric saturation states in binary solid-solution aqueous-solution (SSAS) systems. Lippmann phase diagrams, Roozeboom diagrams, and distribution-coefficient diagrams can be constructed from the output data files, and also can be displayed by MBSSAS (on IBM-PC compatible computers). MBSSAS also will calculate accessory information, such as the location of miscibility gaps, spinodal gaps, critical-mixing points, alyotropic extrema, Henry's law solid-phase activity coefficients, and limiting distribution coefficients. Alternatively, MBSSAS can use such information (instead of the Margules, Guggenheim, or Thompson and Waldbaum excess-free-energy parameters) to calculate the appropriate excess-free-energy of mixing equation for any given SSAS system. ?? 1991.
Solar heat transport fluids for solar energy collection systems: A collection of quarterly reports
NASA Technical Reports Server (NTRS)
1978-01-01
Noncorrosive fluid subsystem is being developed that is compatible with closed-loop solar heating and combined heating and hot water systems. The system is also to be compatible with both metallic and nonmetallic plumbing systems, and any combination of these. At least 100 gallons of each type of fluid recommended by the contractor will be delivered.
Perceptual video quality comparison of 3DTV broadcasting using multimode service systems
NASA Astrophysics Data System (ADS)
Ok, Jiheon; Lee, Chulhee
2015-05-01
Multimode service (MMS) systems allow broadcasters to provide multichannel services using a single HD channel. Using these systems, it is possible to provide 3DTV programs that can be watched either in three-dimensional (3-D) or two-dimensional (2-D) modes with backward compatibility. In the MMS system for 3DTV broadcasting using the Advanced Television Systems Committee standards, the left and the right views are encoded using MPEG-2 and H.264, respectively, and then transmitted using a dual HD streaming format. The left view, encoded using MPEG-2, assures 2-D backward compatibility while the right view, encoded using H.264, can be optionally combined with the left view to generate stereoscopic 3-D views. We analyze 2-D and 3-D perceptual quality when using the MMS system by comparing items in the frame-compatible format (top-bottom), which is a conventional transmission scheme for 3-D broadcasting. We performed perceptual 2-D and 3-D video quality evaluation assuming 3DTV programs are encoded using the MMS system and top-bottom format. The results show that MMS systems can be preferable with regard to perceptual 2-D and 3-D quality and backward compatibility.
Compatibility Studies of Hydrogen Peroxide and a New Hypergolic Fuel Blend
NASA Technical Reports Server (NTRS)
Baldridge, Jennifer; Villegas, Yvonne
2002-01-01
Several preliminary materials compatibility studies have been conducted to determine the practicality of a new hypergolic fuel system. Hypergolic fuel ignites spontaneously as the oxidizer decomposes and releases energy in the presence of the fuel. The bipropellant system tested consists of high-test hydrogen peroxide (HTP) and a liquid fuel blend consisting of a hydrocarbon fuel, an ignition enhancer and a transition metal catalyst. In order for further testing of the new fuel blend to take place, some basic materials compatibility and HTP decomposition studies must be accomplished. The thermal decomposition rate of HTP was tested using gas evolution and isothermal microcalorimetry (IMC). Materials were analyzed for compatibility with hydrogen peroxide including a study of the affect welding has on stainless steel elemental composition and its relation to HTP decomposition. Compatibility studies of valve materials in the fuel blend were performed to determine the corrosion resistance of the materials.
EPA guidance on complying with the federal compatibility requirement for underground storage tank (UST) systems storing gasoline containing greater than 10 percent ethanol or diesel containing greater than 20 percent biodiesel.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-16
...), relating to contact information. e. Section 4(d), relating to optional descriptive materials. 3. If... means it determines suitable to evaluate any entry, award points and determine any winner in this... Compatible. c. Functional Evaluation. VA will evaluate an entry that has demonstrated Technical Compatibility...
ERIC Educational Resources Information Center
Oblinger, Diana G., Ed.; Rush, Sean C., Ed.
This collection of 16 monographs centers around the theme the "future compatible campus," which is based on the premise that higher education will become a "connected campus" in a technology-enabled environment consisting of three components: connected learning, connected service to the community; and connected management. In…
ERIC Educational Resources Information Center
Ershov, Andrei P.
The problem of compatibility of software hampers the development of computer application. One solution lies in standardization of languages, terms, peripherais, operating systems and computer characteristics. (AB)
Carter, William Douglas; Paulson, Richard W.
1979-01-01
The rapid development of satellite technology, especially in the area of radio transmission and imaging systems, makes it possible to monitor dynamic surface phenomena of the Earth in considerable detail. The monitoring systems that have been developed are compatible with standard monitoring systems such as snow, stream, and rain gages; wind, temperature and humidity measuring instruments; tiltmeters and seismic event counters. Supported by appropriate power, radios and antennae, remote stations can be left unattended for at least 1 year and consistently relay local information via polar orbiting or geostationary satellites. These data, in conjunction with timely Landsat images, can provide a basis for more accurate estimates on snowfall, water runoff, reservoir level changes, flooding, drought effects, and vegetation trends and may be of help in forecasting volcanic eruptions. These types of information are critical for resource inventory and development, especially in developing countries where remote regions are commonly difficult to access. This paper introduces the reader to the systems available, describes their features and limitations, and provides suggestions on how to employ them. An extensive bibliography is provided for those who wish more information.
nu/TPU -- A DEC TPU compatible editor for UNIX
NASA Astrophysics Data System (ADS)
Rehan, S. C.
nu/TPU is a fully programmable text processing utility compatible with the TPU system found on VMS systems. People used to using TPU or EDT on the former Starlink VAX/VMS service will find that nu/TPU is very similar to these editors.
NASA Technical Reports Server (NTRS)
Bremmer, D. A.
1986-01-01
The feasibility of some off-the-shelf microprocessors and state-of-art software is assessed (1) as a development system for the principle investigator (pi) in the design of the experiment model, (2) as an example of available technology application for future PI's experiments, (3) as a system capable of being interactive in the PCTC's simulation of the dedicated experiment processor (DEP), preferably by bringing the PI's DEP software directly into the simulation model, (4) as a system having bus compatibility with host VAX simulation computers, (5) as a system readily interfaced with mock-up panels and information displays, and (6) as a functional system for post mission data analysis.
46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...
46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...
46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...
46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...
46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...
Using CLIPS in a distributed system: The Network Control Center (NCC) expert system
NASA Technical Reports Server (NTRS)
Wannemacher, Tom
1990-01-01
This paper describes an intelligent troubleshooting system for the Help Desk domain. It was developed on an IBM-compatible 80286 PC using Microsoft C and CLIPS and an AT&T 3B2 minicomputer using the UNIFY database and a combination of shell script, C programs and SQL queries. The two computers are linked by a lan. The functions of this system are to help non-technical NCC personnel handle trouble calls, to keep a log of problem calls with complete, concise information, and to keep a historical database of problems. The database helps identify hardware and software problem areas and provides a source of new rules for the troubleshooting knowledge base.
NASA Astrophysics Data System (ADS)
Yang, Can; Ma, Cheng; Hu, Linxi; He, Guangqiang
2018-06-01
We present a hierarchical modulation coherent communication protocol, which simultaneously achieves classical optical communication and continuous-variable quantum key distribution. Our hierarchical modulation scheme consists of a quadrature phase-shifting keying modulation for classical communication and a four-state discrete modulation for continuous-variable quantum key distribution. The simulation results based on practical parameters show that it is feasible to transmit both quantum information and classical information on a single carrier. We obtained a secure key rate of 10^{-3} bits/pulse to 10^{-1} bits/pulse within 40 kilometers, and in the meantime the maximum bit error rate for classical information is about 10^{-7}. Because continuous-variable quantum key distribution protocol is compatible with standard telecommunication technology, we think our hierarchical modulation scheme can be used to upgrade the digital communication systems to extend system function in the future.
Calderon, Karynna; Dadisman, S.V.; Kindinger, J.L.; Flocks, J.G.; Wiese, D.S.; Kulp, Mark; Penland, Shea; Britsch, L.D.; Brooks, G.R.
2003-01-01
This archive consists of two-dimensional marine seismic reflection profile data collected in the Barataria Basin of southern Louisiana. These data were acquired in May, June, and July of 2000 aboard the R/V G.K. Gilbert. Included here are data in a variety of formats including binary, American Standard Code for Information Interchange (ASCII), Hyper-Text Markup Language (HTML), shapefiles, and Graphics Interchange Format (GIF) and Joint Photographic Experts Group (JPEG) images. Binary data are in Society of Exploration Geophysicists (SEG) SEG-Y format and may be downloaded for further processing or display. Reference maps and GIF images of the profiles may be viewed with a web browser. The Geographic Information Systems (GIS) information provided here is compatible with Environmental Systems Research Institute (ESRI) GIS software.
Hospital information system: reusability, designing, modelling, recommendations for implementing.
Huet, B
1998-01-01
The aims of this paper are to precise some essential conditions for building reuse models for hospital information systems (HIS) and to present an application for hospital clinical laboratories. Reusability is a general trend in software, however reuse can involve a more or less part of design, classes, programs; consequently, a project involving reusability must be precisely defined. In the introduction it is seen trends in software, the stakes of reuse models for HIS and the special use case constituted with a HIS. The main three parts of this paper are: 1) Designing a reuse model (which objects are common to several information systems?) 2) A reuse model for hospital clinical laboratories (a genspec object model is presented for all laboratories: biochemistry, bacteriology, parasitology, pharmacology, ...) 3) Recommendations for generating plug-compatible software components (a reuse model can be implemented as a framework, concrete factors that increase reusability are presented). In conclusion reusability is a subtle exercise of which project must be previously and carefully defined.
Advanced Chemistry Collection, 2nd Edition
NASA Astrophysics Data System (ADS)
2001-11-01
Software requirements are given in Table 3. Some programs have additional special requirements. Please see the individual program abstracts at JCE Online or the documentation included on the CD-ROM for more specific information. Table 3. General software requirements for the Advanced Chemistry Collection.
| Computer | System | Other Software(Required by one or more programs) |
| Mac OS compatible | System 7.6.1 or higher | Acrobat Reader (included)Mathcad; Mathematica;MacMolecule2; QuickTime 4; HyperCard Player |
| Windows Compatible | Windows 2000, 98, 95, NT 4 | Acrobat Reader (included)Mathcad; Mathematica;PCMolecule2; QuickTime 4;HyperChem; Excel |
Software engineering and data management for automated payload experiment tool
NASA Technical Reports Server (NTRS)
Maddux, Gary A.; Provancha, Anna; Chattam, David
1994-01-01
The Microgravity Projects Office identified a need to develop a software package that will lead experiment developers through the development planning process, obtain necessary information, establish an electronic data exchange avenue, and allow easier manipulation/reformatting of the collected information. An MS-DOS compatible software package called the Automated Payload Experiment Tool (APET) has been developed and delivered. The objective of this task is to expand on the results of the APET work previously performed by UAH and provide versions of the software in a Macintosh and Windows compatible format.
de Oliveira, Neurilene Batista; Peres, Heloisa Helena Ciqueto
2015-01-01
To evaluate the functional performance and the technical quality of the Electronic Documentation System of the Nursing Process of the Teaching Hospital of the University of São Paulo. exploratory-descriptive study. The Quality Model of regulatory standard 25010 and the Evaluation Process defined under regulatory standard 25040, both of the International Organization for Standardization/International Electrotechnical Commission. The quality characteristics evaluated were: functional suitability, reliability, usability, performance efficiency, compatibility, security, maintainability and portability. The sample was made up of 37 evaluators. in the evaluation of the specialists in information technology, only the characteristic of usability obtained a rate of positive responses of less than 70%. For the nurse lecturers, all the quality characteristics obtained a rate of positive responses of over 70%. The staff nurses of the medical and surgical clinics with experience in using the system) and staff nurses from other units of the hospital and from other health institutions (without experience in using the system) obtained rates of positive responses of more than 70% referent to the functional suitability, usability, and security. However, performance efficiency, reliability and compatibility all obtained rates below the parameter established. the software achieved rates of positive responses of over 70% for the majority of the quality characteristics evaluated.
The spurious response of microwave photonic mixer
NASA Astrophysics Data System (ADS)
Xiao, Yongchuan; Zhong, Guoshun; Qu, Pengfei; Sun, Lijun
2018-02-01
Microwave photonic mixer is a potential solution for wideband information systems due to the ultra-wide operating bandwidth, high LO-to-RF isolation, the intrinsic immunity to electromagnetic interference, and the compatibility with exsiting microwave photonic transmission systems. The spurious response of microwave photonic mixer cascading in series a pair of Mach-Zehnder interferometric intensity modulators has been simulated and analyzed in this paper. The low order spurious products caused by the nonlinearity of modulators are non-negligible, and the proper IF frequency and accurate bias-controlling are of great importance to mitigate the impact of spurious products.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
...-126] Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics... between consumer electronics equipment (such as digital television sets) and newly encrypted cable service... Act''), Congress sought to make sure that consumer electronics equipment could receive cable...
Lyon, Aaron R; Wasse, Jessica Knaster; Ludwig, Kristy; Zachry, Mark; Bruns, Eric J; Unützer, Jürgen; McCauley, Elizabeth
2016-05-01
Health information technologies have become a central fixture in the mental healthcare landscape, but few frameworks exist to guide their adaptation to novel settings. This paper introduces the contextualized technology adaptation process (CTAP) and presents data collected during Phase 1 of its application to measurement feedback system development in school mental health. The CTAP is built on models of human-centered design and implementation science and incorporates repeated mixed methods assessments to guide the design of technologies to ensure high compatibility with a destination setting. CTAP phases include: (1) Contextual evaluation, (2) Evaluation of the unadapted technology, (3) Trialing and evaluation of the adapted technology, (4) Refinement and larger-scale implementation, and (5) Sustainment through ongoing evaluation and system revision. Qualitative findings from school-based practitioner focus groups are presented, which provided information for CTAP Phase 1, contextual evaluation, surrounding education sector clinicians' workflows, types of technologies currently available, and influences on technology use. Discussion focuses on how findings will inform subsequent CTAP phases, as well as their implications for future technology adaptation across content domains and service sectors.
Ologeanu-Taddei, R; Morquin, D; Bourret, R
2015-01-01
The goal of this study was to examine the perceived usefulness and the perceived ease of use of a Hospital Information System (HIS) for the care staff. We administrated a questionnaire composed of open-end and closed questions. As results, the perceived usefulness and ease of use are correlated with medical occupations. Content analysis of open questions highlights three factors influencing these constructs: ergonomics, errors in the documenting process and insufficient compatibility with the medical department or the occupation. While the results are consistent with literature, they show medical occupations do not report the same low rate of perceived usefulness and of ease of use. The main explanation consists in the medical risk in the prescription process for anesthesiologists, surgeons and physicians.
Neighboring block based disparity vector derivation for multiview compatible 3D-AVC
NASA Astrophysics Data System (ADS)
Kang, Jewon; Chen, Ying; Zhang, Li; Zhao, Xin; Karczewicz, Marta
2013-09-01
3D-AVC being developed under Joint Collaborative Team on 3D Video Coding (JCT-3V) significantly outperforms the Multiview Video Coding plus Depth (MVC+D) which simultaneously encodes texture views and depth views with the multiview extension of H.264/AVC (MVC). However, when the 3D-AVC is configured to support multiview compatibility in which texture views are decoded without depth information, the coding performance becomes significantly degraded. The reason is that advanced coding tools incorporated into the 3D-AVC do not perform well due to the lack of a disparity vector converted from the depth information. In this paper, we propose a disparity vector derivation method utilizing only the information of texture views. Motion information of neighboring blocks is used to determine a disparity vector for a macroblock, so that the derived disparity vector is efficiently used for the coding tools in 3D-AVC. The proposed method significantly improves a coding gain of the 3D-AVC in the multiview compatible mode about 20% BD-rate saving in the coded views and 26% BD-rate saving in the synthesized views on average.
Cardiological database management system as a mediator to clinical decision support.
Pappas, C; Mavromatis, A; Maglaveras, N; Tsikotis, A; Pangalos, G; Ambrosiadou, V
1996-03-01
An object-oriented medical database management system is presented for a typical cardiologic center, facilitating epidemiological trials. Object-oriented analysis and design were used for the system design, offering advantages for the integrity and extendibility of medical information systems. The system was developed using object-oriented design and programming methodology, the C++ language and the Borland Paradox Relational Data Base Management System on an MS-Windows NT environment. Particular attention was paid to system compatibility, portability, the ease of use, and the suitable design of the patient record so as to support the decisions of medical personnel in cardiovascular centers. The system was designed to accept complex, heterogeneous, distributed data in various formats and from different kinds of examinations such as Holter, Doppler and electrocardiography.
Land use and environmental assessment in the central Atlantic region
NASA Technical Reports Server (NTRS)
Alexander, R. H.; Fitzpatrick, K.; Lins, H. F., Jr.; Mcginty, H. K., III
1975-01-01
Data from high altitude aircraft, LANDSAT and Skylab were used in a comprehensive regional survey of land use and its associated environmental impact in the Central Atlantic Regional Ecological Test Site (CARETS). Each sensor system has advantages that were demonstrated by producing experimental land use maps and other data products, applying them to typical problems encountered in regional planning and environmental impact assessment, and presenting the results to prospective users for evaluation. An archival collection of imagery, maps, data summaries, and technical reports was assembled, constituting an environmental profile of the central Atlantic region. The investigation was organized into four closely-related modules, a land use information module, an environmental impact module, a user interaction and evaluation module, and a geographic information systems module. Results revealed a heterogeneous user community with diverse information needs, tending, however, definitely toward the higher-resolution sensor data and the larger-scale land use maps and related information products. Among project recommendations are greater efforts toward improving compatibility of federal, state, and local land use information programs, and greater efforts toward a broader exchange of imagery, computer tapes, and land use information derived therefrom.
Entropic Nonsignaling Correlations.
Chaves, Rafael; Budroni, Costantino
2016-06-17
We introduce the concept of entropic nonsignaling correlations, i.e., entropies arising from probabilistic theories that are compatible with the fact that we cannot transmit information instantaneously. We characterize and show the relevance of these entropic correlations in a variety of different scenarios, ranging from typical Bell experiments to more refined descriptions such as bilocality and information causality. In particular, we apply the framework to derive the first entropic inequality testing genuine tripartite nonlocality in quantum systems of arbitrary dimension and also prove the first known monogamy relation for entropic Bell inequalities. Further, within the context of complex Bell networks, we show that entropic nonlocal correlations can be activated.
Matrix-addressed analog ferroelectric memory
NASA Astrophysics Data System (ADS)
Lemons, R. A.; Grogan, J. K.; Thompson, J. S.
1980-08-01
A matrix addressed analog memory which uses multiple ferroelectric domain walls to address columns of words, is demonstrated. It is shown that the analog information is stored as a pattern in the metallization on the surface of the crystal, making a read-only memory. The pattern is done photolithographically in a way compatible with the simultaneous fabrication of many devices. Attention is given to the performance results, noting that the advantage of the device is that analog information can be stored with a high density in a single mask step. Finally, it is shown that potential applications are in systems which require repetitive output from a limited vocabulary of spoken words.
Entropic Nonsignaling Correlations
NASA Astrophysics Data System (ADS)
Chaves, Rafael; Budroni, Costantino
2016-06-01
We introduce the concept of entropic nonsignaling correlations, i.e., entropies arising from probabilistic theories that are compatible with the fact that we cannot transmit information instantaneously. We characterize and show the relevance of these entropic correlations in a variety of different scenarios, ranging from typical Bell experiments to more refined descriptions such as bilocality and information causality. In particular, we apply the framework to derive the first entropic inequality testing genuine tripartite nonlocality in quantum systems of arbitrary dimension and also prove the first known monogamy relation for entropic Bell inequalities. Further, within the context of complex Bell networks, we show that entropic nonlocal correlations can be activated.
48 CFR 3439.703 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... OF EDUCATION ACQUISITION REGULATION SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Department Requirements for Acquisition of Information Technology 3439.703 Federal desktop core...
48 CFR 3439.703 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2012 CFR
2012-10-01
... OF EDUCATION ACQUISITION REGULATION SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Department Requirements for Acquisition of Information Technology 3439.703 Federal desktop core...
48 CFR 3439.703 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF EDUCATION ACQUISITION REGULATION SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Department Requirements for Acquisition of Information Technology 3439.703 Federal desktop core...
48 CFR 3439.703 - Federal desktop core configuration (FDCC) compatibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... OF EDUCATION ACQUISITION REGULATION SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Department Requirements for Acquisition of Information Technology 3439.703 Federal desktop core...
Next generation keyboards: The importance of cognitive compatibility
NASA Technical Reports Server (NTRS)
Amell, John R.; Ewry, Michael E.; Colle, Herbert A.
1988-01-01
The computer keyboard of today is essentially the same as it has been for many years. Few advances have been made in keyboard design even though computer systems in general have made remarkable progress in improvements. This paper discusses the future of keyboards, their competition and compatibility with voice input systems, and possible special-application intelligent keyboards for controlling complex systems.
Phillips, Joshua; Chilukuri, Ram; Fragoso, Gilberto; Warzel, Denise; Covitz, Peter A
2006-01-01
Background Robust, programmatically accessible biomedical information services that syntactically and semantically interoperate with other resources are challenging to construct. Such systems require the adoption of common information models, data representations and terminology standards as well as documented application programming interfaces (APIs). The National Cancer Institute (NCI) developed the cancer common ontologic representation environment (caCORE) to provide the infrastructure necessary to achieve interoperability across the systems it develops or sponsors. The caCORE Software Development Kit (SDK) was designed to provide developers both within and outside the NCI with the tools needed to construct such interoperable software systems. Results The caCORE SDK requires a Unified Modeling Language (UML) tool to begin the development workflow with the construction of a domain information model in the form of a UML Class Diagram. Models are annotated with concepts and definitions from a description logic terminology source using the Semantic Connector component. The annotated model is registered in the Cancer Data Standards Repository (caDSR) using the UML Loader component. System software is automatically generated using the Codegen component, which produces middleware that runs on an application server. The caCORE SDK was initially tested and validated using a seven-class UML model, and has been used to generate the caCORE production system, which includes models with dozens of classes. The deployed system supports access through object-oriented APIs with consistent syntax for retrieval of any type of data object across all classes in the original UML model. The caCORE SDK is currently being used by several development teams, including by participants in the cancer biomedical informatics grid (caBIG) program, to create compatible data services. caBIG compatibility standards are based upon caCORE resources, and thus the caCORE SDK has emerged as a key enabling technology for caBIG. Conclusion The caCORE SDK substantially lowers the barrier to implementing systems that are syntactically and semantically interoperable by providing workflow and automation tools that standardize and expedite modeling, development, and deployment. It has gained acceptance among developers in the caBIG program, and is expected to provide a common mechanism for creating data service nodes on the data grid that is under development. PMID:16398930
Experimental Interactions of Components of Hemodialysis Units with Human Blood
Zucker, W. H.; Shinoda, B. A.; Mason, R. G.
1974-01-01
An in vitro model test system for estimation of the blood compatibility of hemodialysis membranes and tubing is described. The model test system consists of a modified hemodialysis unit and blood pump through which fresh citrated human blood is circulated. The effects of the use of different pump and tubing types upon hematologic and blood coagulation parameters are described. Preexposure of test surfaces to albumin appeared to enhance blood compatibility characteristics of the model test system, whereas preexposure to a high density lipoprotein preparation or a proteinpolysaccharide preparation was without appreciable benefit. Use of blood from subjects receiving aspirin resulted in enhanced blood compatibility in the test system as did use of heparin. Use of Warfarin or dextran did not appear to enhance blood compatibility of test surfaces under the conditions of this test system. Dialysis membranes and tubing which formed parts of the test system were examined by scanning and transmission electron microscopy in control tests and in tests for effects of proteins and antithrombotic agents. ImagesFig 5Fig 6Fig 7Fig 8Fig 9Fig 10Fig 11Fig 12Fig 13Fig 14Fig 1Fig 2Fig 3Fig 4 PMID:4825611
[Compatible biomass models of natural spruce (Picea asperata)].
Wang, Jin Chi; Deng, Hua Feng; Huang, Guo Sheng; Wang, Xue Jun; Zhang, Lu
2017-10-01
By using nonlinear measurement error method, the compatible tree volume and above ground biomass equations were established based on the volume and biomass data of 150 sampling trees of natural spruce (Picea asperata). Two approaches, controlling directly under total aboveground biomass and controlling jointly from level to level, were used to design the compatible system for the total aboveground biomass and the biomass of four components (stem, bark, branch and foliage), and the total ground biomass could be estimated independently or estimated simultaneously in the system. The results showed that the R 2 of the one variable and bivariate compatible tree volume and aboveground biomass equations were all above 0.85, and the maximum value reached 0.99. The prediction effect of the volume equations could be improved significantly when tree height was included as predictor, while it was not significant in biomass estimation. For the compatible biomass systems, the one variable model based on controlling jointly from level to level was better than the model using controlling directly under total above ground biomass, but the bivariate models of the two methods were similar. Comparing the imitative effects of the one variable and bivariate compatible biomass models, the results showed that the increase of explainable variables could significantly improve the fitness of branch and foliage biomass, but had little effect on other components. Besides, there was almost no difference between the two methods of estimation based on the comparison.
New optical architecture for holographic data storage system compatible with Blu-ray Disc™ system
NASA Astrophysics Data System (ADS)
Shimada, Ken-ichi; Ide, Tatsuro; Shimano, Takeshi; Anderson, Ken; Curtis, Kevin
2014-02-01
A new optical architecture for holographic data storage system which is compatible with a Blu-ray Disc™ (BD) system is proposed. In the architecture, both signal and reference beams pass through a single objective lens with numerical aperture (NA) 0.85 for realizing angularly multiplexed recording. The geometry of the architecture brings a high affinity with an optical architecture in the BD system because the objective lens can be placed parallel to a holographic medium. Through the comparison of experimental results with theory, the validity of the optical architecture was verified and demonstrated that the conventional objective lens motion technique in the BD system is available for angularly multiplexed recording. The test-bed composed of a blue laser system and an objective lens of the NA 0.85 was designed. The feasibility of its compatibility with BD is examined through the designed test-bed.
N2pc is modulated by stimulus-stimulus, but not by stimulus-response incompatibilities.
Cespón, J; Galdo-Álvarez, S; Díaz, F
2013-04-01
Studies of the N2pc in Simon-type tasks have revealed inconsistent results. That is, N2pc was only modulated when a stimulus-stimulus (S-S) overlap covaries with the stimulus-response (S-R) overlap. The present study aimed to establish whether N2pc is modulated by the S-R or by the S-S overlap. Therefore, we designed a Simon task requiring response to a colour stimulus (an arrow) with two irrelevant dimensions (position and direction). The following conditions were thus generated: compatible direction-compatible position (CDCP); incompatible direction-compatible position (IDCP); compatible direction-incompatible position (CDIP); and incompatible direction-incompatible position (IDIP). In IDCP and CDIP, both irrelevant dimensions conveyed contradictory spatial information (S-S incompatibility), while compatibility between both irrelevant dimensions occurred in CDCP and IDIP (the direction indicated was compatible with stimulus position). The N2pc amplitude was smaller in IDCP and CDIP than in CDCP and IDIP, what suggests that N2pc was modulated by S-S incompatibility and not by S-R incompatibilities. Copyright © 2013 Elsevier B.V. All rights reserved.
Spatial compatibility and affordance compatibility in patients with chronic schizophrenia.
Kume, Yu; Sato, Fumiyasu; Hiraoka, Yuya; Suzuki, Shingo; Niyama, Yoshitsugu
2016-12-01
A deterioration in information-processing performance is commonly recognized in patients with chronic schizophrenia. Although the enhancement of cognitive skills in patients with schizophrenia is important, the types of external stimuli that influence performance have not received much attention. The aim of present study was to clarify the effects of spatial and affordance compatibility in patients with schizophrenia, compared with those in healthy people. The subjects (25 patients with schizophrenia and 25 healthy controls) participated in two experiment examining the effects of the spatial location of stimuli and the action-relevance of objects. The results showed that the effect of spatial compatibility was similar in both the patients and the controls, whereas the influence of action-relevant objects was not highlighted in either patients with chronic schizophrenia or healthy controls. These findings provide important evidence of a normal spatial compatibility effect in patients with chronic schizophrenia. However, further research examining the affordance compatibility effect is needed, taking into consideration the symptomatology and the severity of the social functioning level in patients with schizophrenia. Copyright © 2016 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-21
... provides an online reporting tool to support the annual HSIP reporting process. Additional information is.../ . Reporting into the online reporting tool meets all report requirements and USDOT Web site compatibility...
MIMS - MEDICAL INFORMATION MANAGEMENT SYSTEM
NASA Technical Reports Server (NTRS)
Frankowski, J. W.
1994-01-01
MIMS, Medical Information Management System is an interactive, general purpose information storage and retrieval system. It was first designed to be used in medical data management, and can be used to handle all aspects of data related to patient care. Other areas of application for MIMS include: managing occupational safety data in the public and private sectors; handling judicial information where speed and accuracy are high priorities; systemizing purchasing and procurement systems; and analyzing organizational cost structures. Because of its free format design, MIMS can offer immediate assistance where manipulation of large data bases is required. File structures, data categories, field lengths and formats, including alphabetic and/or numeric, are all user defined. The user can quickly and efficiently extract, display, and analyze the data. Three means of extracting data are provided: certain short items of information, such as social security numbers, can be used to uniquely identify each record for quick access; records can be selected which match conditions defined by the user; and specific categories of data can be selected. Data may be displayed and analyzed in several ways which include: generating tabular information assembled from comparison of all the records on the system; generating statistical information on numeric data such as means, standard deviations and standard errors; and displaying formatted listings of output data. The MIMS program is written in Microsoft FORTRAN-77. It was designed to operate on IBM Personal Computers and compatibles running under PC or MS DOS 2.00 or higher. MIMS was developed in 1987.
Jiao, Wei; Xie, Li; Li, Hailan; Lan, Jiao; Mo, Zhuning; Yang, Ziji; Liu, Fei; Xiao, Ruiping; He, Yunlei; Ye, Luyi; Zhu, Ziyan
2014-04-01
To screen rare blood groups Fy(a-), s-, k-, Di(b-) and Js(b-) in an ethnic Zhuang population. Sequence-specific primers were designed based on single nucleotide polymorphism (SNP) sites of blood group antigens Fy(b) and s. A specific multiplex PCR system I was established. Multiplex PCR system II was applied to detect alleles antigens Di(b), k, Js(b)1910 and Js(b) 2019 at the same time. The two systems was were used to screen for rare blood group antigens in 4490 randomly selected healthy donors of Guangxi Zhuang ethnic origin. We successfully made the multiplex PCR system I. We detected the rare blood group antigens using the two PCR system. There are five Fy(a-), three s(-), two Di(b-) in 4490 Guangxi zhuang random samples. The multiplex PCR system I has achieved good accuracy and stability. With multiplex PCR systems I and II, 4490 samples were screened. Five Fy(a-), three s(-) and two Di(b-) samples were discovered. Multiplex PCR is an effective methods, which can be used for high throughput screening of rare blood groups. The rare blood types of Guangxi Zhuang ethnic origin obtained through the screening can provide valuable information for compatible blood transfusion. Through screening we obtained precious rare blood type materials which can be used to improve the capability of compatible infusion and reduce the transfusion reactions.
Processing abstract language modulates motor system activity.
Glenberg, Arthur M; Sato, Marc; Cattaneo, Luigi; Riggio, Lucia; Palumbo, Daniele; Buccino, Giovanni
2008-06-01
Embodiment theory proposes that neural systems for perception and action are also engaged during language comprehension. Previous neuroimaging and neurophysiological studies have only been able to demonstrate modulation of action systems during comprehension of concrete language. We provide neurophysiological evidence for modulation of motor system activity during the comprehension of both concrete and abstract language. In Experiment 1, when the described direction of object transfer or information transfer (e.g., away from the reader to another) matched the literal direction of a hand movement used to make a response, speed of responding was faster than when the two directions mismatched (an action-sentence compatibility effect). In Experiment 2, we used single-pulse transcranial magnetic stimulation to study changes in the corticospinal motor pathways to hand muscles while reading the same sentences. Relative to sentences that do not describe transfer, there is greater modulation of activity in the hand muscles when reading sentences describing transfer of both concrete objects and abstract information. These findings are discussed in relation to the human mirror neuron system.
Addressable configurations of DNA nanostructures for rewritable memory
Levchenko, Oksana; Patel, Dhruv S.; MacIsaac, Molly
2017-01-01
Abstract DNA serves as nature's information storage molecule, and has been the primary focus of engineered systems for biological computing and data storage. Here we combine recent efforts in DNA self-assembly and toehold-mediated strand displacement to develop a rewritable multi-bit DNA memory system. The system operates by encoding information in distinct and reversible conformations of a DNA nanoswitch and decoding by gel electrophoresis. We demonstrate a 5-bit system capable of writing, erasing, and rewriting binary representations of alphanumeric symbols, as well as compatibility with ‘OR’ and ‘AND’ logic operations. Our strategy is simple to implement, requiring only a single mixing step at room temperature for each operation and standard gel electrophoresis to read the data. We envision such systems could find use in covert product labeling and barcoding, as well as secure messaging and authentication when combined with previously developed encryption strategies. Ultimately, this type of memory has exciting potential in biomedical sciences as data storage can be coupled to sensing of biological molecules. PMID:28977499
Semantic World Modelling and Data Management in a 4d Forest Simulation and Information System
NASA Astrophysics Data System (ADS)
Roßmann, J.; Hoppen, M.; Bücken, A.
2013-08-01
Various types of 3D simulation applications benefit from realistic forest models. They range from flight simulators for entertainment to harvester simulators for training and tree growth simulations for research and planning. Our 4D forest simulation and information system integrates the necessary methods for data extraction, modelling and management. Using modern methods of semantic world modelling, tree data can efficiently be extracted from remote sensing data. The derived forest models contain position, height, crown volume, type and diameter of each tree. This data is modelled using GML-based data models to assure compatibility and exchangeability. A flexible approach for database synchronization is used to manage the data and provide caching, persistence, a central communication hub for change distribution, and a versioning mechanism. Combining various simulation techniques and data versioning, the 4D forest simulation and information system can provide applications with "both directions" of the fourth dimension. Our paper outlines the current state, new developments, and integration of tree extraction, data modelling, and data management. It also shows several applications realized with the system.
Lavie, N
1997-05-01
Predictions from Treisman's feature integration theory of attention were tested in a variant of the response-competition paradigm. Subjects made choice responses to particular color-shape conjunctions (e.g., a purple cross vs. a green circle) while withholding their responses to the opposite conjunctions (i.e., a purple circle vs. a green cross). The results showed that compatibility effects were based on both distractor color and shape. For unattended distractors in preknown irrelevant positions, compatibility effects were equivalent for conjunctive distractors (e.g., a purple cross and a blue triangle) and for disjunctive distractors (e.g., a purple triangle and a blue cross). Manipulation of attention to the distractors positions resulted in larger compatibility effects from conjoined features. These results accord with Treisman's claim that correct conjunction information is unavailable under conditions of inattention, and they provide new information on response-competition effects from multiple features.
Multi-modal distraction: insights from children's limited attention.
Matusz, Pawel J; Broadbent, Hannah; Ferrari, Jessica; Forrest, Benjamin; Merkley, Rebecca; Scerif, Gaia
2015-03-01
How does the multi-sensory nature of stimuli influence information processing? Cognitive systems with limited selective attention can elucidate these processes. Six-year-olds, 11-year-olds and 20-year-olds engaged in a visual search task that required them to detect a pre-defined coloured shape under conditions of low or high visual perceptual load. On each trial, a peripheral distractor that could be either compatible or incompatible with the current target colour was presented either visually, auditorily or audiovisually. Unlike unimodal distractors, audiovisual distractors elicited reliable compatibility effects across the two levels of load in adults and in the older children, but high visual load significantly reduced distraction for all children, especially the youngest participants. This study provides the first demonstration that multi-sensory distraction has powerful effects on selective attention: Adults and older children alike allocate attention to potentially relevant information across multiple senses. However, poorer attentional resources can, paradoxically, shield the youngest children from the deleterious effects of multi-sensory distraction. Furthermore, we highlight how developmental research can enrich the understanding of distinct mechanisms controlling adult selective attention in multi-sensory environments. Copyright © 2014 Elsevier B.V. All rights reserved.
Virtual shelves in a digital library: a framework for access to networked information sources.
Patrick, T B; Springer, G K; Mitchell, J A; Sievert, M E
1995-01-01
Develop a framework for collections-based access to networked information sources that addresses the problem of location-dependent access to information sources. This framework uses a metaphor of a virtual shelf. A virtual shelf is a general-purpose server that is dedicated to a particular information subject class. The identifier of one of these servers identifies its subject class. Location-independent call numbers are assigned to information sources. Call numbers are based on standard vocabulary codes. The call numbers are first mapped to the location-independent identifiers of virtual shelves. When access to an information resource is required, a location directory provides a second mapping of these location-independent server identifiers to actual network locations. The framework has been implemented in two different systems. One system is based on the Open System Foundation/Distributed Computing Environment and the other is based on the World Wide Web. This framework applies in new ways traditional methods of library classification and cataloging. It is compatible with two traditional styles of selecting information searching and browsing. Traditional methods may be combined with new paradigms of information searching that will be able to take advantage of the special properties of digital information. Cooperation between the library-informational science community and the informatics community can provide a means for a continuing application of the knowledge and techniques of library science to the new problems of networked information sources.
Zhang, Cui-Ying; Ren, Wei-Guang
2017-06-01
Herb pairs are usual clinical compatibility forms and one of compound prescription sources in Chinese medicine. Pharmacokinetic research in vivo is one of the important items in elucidating the mechanism for synergistic and attenuated mechanisms of herb pairs. The paper comprehensively summarized and systemized the pharmacokinetic researches of marker-ingredients about Danshen-Honghua and Danshen-Bingpian in order to elucidate the rationality and scientificity of herb pairs and provide some feasible suggestions on the pharmacokinetics of drugs in the future. In view of complicated system of Traditional Chinese medicines and a chemical system that is not separated from its natural state, comparative pharmacokinetic researches on marker-ingredients from the herb pairs are reasonable to elucidate the synergistic and attenuated mechanisms of monarch-subjects compatible herbs and monarch-guide compatible herbs. Such pharmacokinetic research can better explain the mechanism of drug compatibility, while the pharmacokinetic researches based on the monomer chemical compositions and marker-ingredients that have been separated from complex chemical environment of traditional Chinese Medicine are still unreasonable and should be discussed deeply. Copyright© by the Chinese Pharmaceutical Association.
Heo, Youn-Jung; Jung, Yen-Sook; Hwang, Kyeongil; Kim, Jueng-Eun; Yeo, Jun-Seok; Lee, Sehyun; Jeon, Ye-Jin; Lee, Donmin; Kim, Dong-Yu
2017-11-15
For the first time, the photovoltaic modules composed of small molecule were successfully fabricated by using roll-to-roll compatible printing techniques. In this study, blend films of small molecules, BTR and PC 71 BM were slot-die coated using a halogen-free solvent system. As a result, high efficiencies of 7.46% and 6.56% were achieved from time-consuming solvent vapor annealing (SVA) treatment and roll-to-roll compatible solvent additive approaches, respectively. After successful verification of our roll-to-roll compatible method on small-area devices, we further fabricated large-area photovoltaic modules with a total active area of 10 cm 2 , achieving a power conversion efficiency (PCE) of 4.83%. This demonstration of large-area photovoltaic modules through roll-to-roll compatible printing methods, even based on a halogen-free solvent, suggests the great potential for the industrial-scale production of organic solar cells (OSCs).
NASA Technical Reports Server (NTRS)
1974-01-01
The Terminal Area Compatibility (TAC) study is briefly summarized for background information. The most important research items for the areas of noise congestion, and emissions are identified. Other key research areas are also discussed. The 50 recommended research items are categorized by flight phase, technology, and compatibility benefits. The relationship of the TAC recommendations to the previous ATT recommendations is discussed. The bulk of the document contains the 50 recommended research items. For each item, the potential payoff, state of readiness, recommended action and estimated cost and schedule are given.
NASA Astrophysics Data System (ADS)
Szabó, József; Pásztor, László; Dombos, Miklós; Bakacsi, Zsófia; Laborczi, Annamária; Pirkó, Béla; Szabóné Kele, Gabriella
2010-05-01
A successful proposal within the Environment and Energy Operational Programme for informatics development aimed at environmental protection in public administration (e-environmental protection) opened the feasibility of a program for the establishment of a national soil monitoring system for the follow up of the harmful changes in soil conditions and functioning. The aim of the project is to collect, manage, analyse and publish soil data related to the state of soils and the environmental stresses attributed to the pressures due to agriculture setting up an appropriate information system in order to fulfil the directives of the Thematic Strategy for Soil Protection. Further objective is the web-based publication of soil data as well as information to support the related public service mission and to inform publicity. The developed information system will operate as the Soil Degradation Subsystem of the National Environmental Information System being compatible with its other elements. A suitable representative sampling method will be elaborated. The representativity is meant for soil associations, landuse, agricultural practices and typical degradation processes. Soil data will be collected on county levels led by regional representatives but altogether will be representative for the whole territory of Hungary. In our present paper the scheme and conceptual model of the system is presented in the hope of getting useful criticism and ideas from the session participants, which can be built into the system before the project starts in this summer.
Strawman payload data for science and applications space platforms
NASA Technical Reports Server (NTRS)
1980-01-01
The need for a free flying science and applications space platform to host compatible long duration experiment groupings in Earth orbit is discussed. Experiment level information on strawman payload models is presented which serves to identify and quantify the requirements for the space platform system. A description data base on the strawman payload model is presented along with experiment level and group level summaries. Payloads identified in the strawman model include the disciplines of resources observations and environmental observations.
Wetland mapping from digitized aerial photography. [Sheboygen Marsh, Sheboygen County, Wisconsin
NASA Technical Reports Server (NTRS)
Scarpace, F. L.; Quirk, B. K.; Kiefer, R. W.; Wynn, S. L.
1981-01-01
Computer assisted interpretation of small scale aerial imagery was found to be a cost effective and accurate method of mapping complex vegetation patterns if high resolution information is desired. This type of technique is suited for problems such as monitoring changes in species composition due to environmental factors and is a feasible method of monitoring and mapping large areas of wetlands. The technique has the added advantage of being in a computer compatible form which can be transformed into any georeference system of interest.
Technical Data Interoperability (TDI) Pathfinder Via Emerging Standards
NASA Technical Reports Server (NTRS)
Conroy, Mike; Gill, Paul; Hill, Bradley; Ibach, Brandon; Jones, Corey; Ungar, David; Barch, Jeffrey; Ingalls, John; Jacoby, Joseph; Manning, Josh;
2014-01-01
The TDI project (TDI) investigates trending technical data standards for applicability to NASA vehicles, space stations, payloads, facilities, and equipment. TDI tested COTS software compatible with a certain suite of related industry standards for capabilities of individual benefits and interoperability. These standards not only esnable Information Technology (IT) efficiencies, but also address efficient structures and standard content for business processes. We used source data from generic industry samples as well as NASA and European Space Agency (ESA) data from space systems.
1986-11-15
Richard E. Broome [Broome 1985], Major Robert M. DiBona [ DiBona 1985], Major Robert A. Kirsch II [Kirsch 1985], and Major Alan F. Noel, Jr. [Noel 1985...Major Kirsch expanded this prototype to be compatible with the emerging Federal standards for dictionary systems. Major DiBona analyzed data validation...described in [Noel 1985, Kirsch 1985]. The implementation of edit validation rules in a dictionary environment is covered in [ DiBona 1985] and implementation
The integration of a LANDSAT analysis capability with a geographic information system
NASA Technical Reports Server (NTRS)
Nordstrand, E. A.
1981-01-01
The integration of LANDSAT data was achieved through the development of a flexible, compatible analysis tool and using an existing data base to select the usable data from a LANDSAT analysis. The software package allows manipulation of grid cell data plus the flexibility to allow the user to include FORTRAN statements for special functions. Using this combination of capabilities the user can classify a LANDSAT image and then selectivity merge the results with other data that may exist for the study area.
Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition.
Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Muftuler, L Tugan; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan
2010-03-21
In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B(0) field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.
Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition
NASA Astrophysics Data System (ADS)
Hamamura, Mark J.; Ha, Seunghoon; Roeck, Werner W.; Tugan Muftuler, L.; Wagenaar, Douglas J.; Meier, Dirk; Patt, Bradley E.; Nalcioglu, Orhan
2010-03-01
In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B0 field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.
A comprehensive operating room information system using the Kinect sensors and RFID.
Nouei, Mahyar Taghizadeh; Kamyad, Ali Vahidian; Soroush, Ahmad Reza; Ghazalbash, Somayeh
2015-04-01
Occasionally, surgeons do need various types of information to be available rapidly, efficiently and safely during surgical procedures. Meanwhile, they need to free up hands throughout the surgery to necessarily access the mouse to control any application in the sterility mode. In addition, they are required to record audio as well as video files, and enter and save some data. This is an attempt to develop a comprehensive operating room information system called "Medinav" to tackle all mentioned issues. An integrated and comprehensive operating room information system is introduced to be compatible with Health Level 7 (HL7) and digital imaging and communications in medicine (DICOM). DICOM is a standard for handling, storing, printing, and transmitting information in medical imaging. Besides, a natural user interface (NUI) is designed specifically for operating rooms where touch-less interactions with finger and hand tracking are in use. Further, the system could both record procedural data automatically, and view acquired information from multiple perspectives graphically. A prototype system is tested in a live operating room environment at an Iranian teaching hospital. There are also contextual interviews and usability satisfaction questionnaires conducted with the "MediNav" system to investigate how useful the proposed system could be. The results reveal that integration of these systems into a complete solution is the key to not only stream up data and workflow but maximize surgical team usefulness as well. It is now possible to comprehensively collect and visualize medical information, and access a management tool with a touch-less NUI in a rather quick, practical, and harmless manner.
1984-10-01
8217:- . . . .:- . . . * *. . - . . -’" - *. - . " . * - -A REFERENCES [1] J. L. Bogdanor , et. al., Intrasystem Electromagnetic Compatibility Analy- sis Program, Technical Report, RADC-TR-74...286, Vol. IV A, Rome Air -.- Development Center, Griffiss AFB, NY, November 1982. [30] J0 B. Bogdanor , M. D. Siegel, G. L. Weinstock, Intra-Vehicle
Space construction system analysis study: Project systems and missions descriptions
NASA Technical Reports Server (NTRS)
1979-01-01
Three project systems are defined and summarized. The systems are: (1) a Solar Power Satellite (SPS) Development Flight Test Vehicle configured for fabrication and compatible with solar electric propulsion orbit transfer; (2) an Advanced Communications Platform configured for space fabrication and compatible with low thrust chemical orbit transfer propulsion; and (3) the same Platform, configured to be space erectable but still compatible with low thrust chemical orbit transfer propulsion. These project systems are intended to serve as configuration models for use in detailed analyses of space construction techniques and processes. They represent feasible concepts for real projects; real in the sense that they are realistic contenders on the list of candidate missions currently projected for the national space program. Thus, they represent reasonable configurations upon which to base early studies of alternative space construction processes.
Sensor Systems for Space Life Sciences
NASA Technical Reports Server (NTRS)
Somps, Chris J.; Hines, John W.; Connolly, John P. (Technical Monitor)
1995-01-01
Sensors 2000! (S2K!) is a NASA Ames Research Center engineering initiative designed to provide biosensor and bio-instrumentation systems technology expertise to NASA's life sciences spaceflight programs. S2K! covers the full spectrum of sensor technology applications, ranging from spaceflight hardware design and fabrication to advanced technology development, transfer and commercialization. S2K! is currently developing sensor systems for space biomedical applications on BION (a Russian biosatellite focused on Rhesus Monkey physiology) and NEUROLAB (a Space Shuttle flight devoted to neuroscience). It's Advanced Technology Development-Biosensors (ATD-B) project focuses efforts in five principle areas: biotelemetry Systems, chemical and biological sensors, physiological sensors, advanced instrumentation architectures, and data and information management. Technologies already developed and tested included, application-specific sensors, preamplifier hybrids, modular programmable signal conditioners, power conditioning and distribution systems, and a fully implantable dual channel biotelemeter. Systems currently under development include a portable receiver system compatible with an off-the-shelf analog biotelemeter, a 4 channel digital biotelemetry system which monitors pH, a multichannel, g-processor based PCM biotelemetry system, and hand-held personal monitoring systems. S2K! technology easily lends itself to telescience and telemedicine applications as a front-end measurement and data acquisition device, suitable for obtaining and configuring physiological information, and processing that information under control from a remote location.
International Symposium on Electromagnetic Compatibility, Wakefield, MA, August 20-22, 1985, Record
NASA Astrophysics Data System (ADS)
Various papers on electromagnetic compatibility are presented. The general topics addressed include: EMI transient/impulsive disturbances, electromagnetic shielding, antennas and propagation, measurement technology, anechoic chamber/open site measurements, communications systems, electrostatic discahrge, cables/transmission lines. Also considered are: elecromagnetic environments, antennas, electromagnetic pulse, nonlinear effect, computer/data transmission systems, EMI standards and requirements, enclosures/TEM cells, systems EMC, and test site measurements.
76 FR 39095 - Compatibility of Underground Storage Tank Systems With Biofuel Blends
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... drinking water for nearly half of all Americans, the U.S. Environmental Protection Agency (EPA) regulates... components of the UST system, such as leak detection devices, sealants, and containment sumps, may not be... demonstration of compatibility. Some commenters suggested that EPA allow the National Work Group on Leak...
Development of a Communication System Compatible with Chemical Protective Clothing and Equipment.
1986-06-23
for the Chemical Protective Clothing Communication System are discussed in the operation manuals for the engineering prototypes of the trans- ceiver...Report Date DEVELOPMENT OF A COMMUNICATION SYSTEM COMPATIBLE June 1986 WITH CHEMICAL PROTECTIVE CLOTHING AND EQUIPMENT 6. Performing Organization Code 8...Abstract - ’The U. S. Coast Guard and NASA joined in a project to develop a cominications system to operate inside protective suits used in chemical spill
Test operations procedure (TOP) 1-2-512 electromagnetic compatibility tests
NASA Astrophysics Data System (ADS)
1995-05-01
This TOP provides guidance for the planning, execution, and reporting of grounding and bonding and electromagnetic compatibility (EMC) tests of electrical, electronic, and electrochemical equipment, subsystems, and systems.
NASA Technical Reports Server (NTRS)
Misra, Ajay K.
1989-01-01
Chemical compatibility of several reinforcement materials with three niobium aluminides, Nb3Al, Nb2Al, and NbAl3, were examined from thermodynamic considerations. The reinforcement materials considered in this study include carbides, borides, nitrides, oxides, silicides, and Engel-Brewer compounds. Thermodynamics of the Nb-Al system were reviewed and activities of Nb and Al were derived at desired calculation temperatures. Criteria for chemical compatibility between the reinforcement material and Nb-Al compounds have been defined and several chemically compatible reinforcement materials have been identified.
NASA Technical Reports Server (NTRS)
Weldon, W. F.
1980-01-01
The applicability/compatibility of inertial energy storage systems like the homopolar generator (HPG) and the compensated pulsed alternator (CPA) to future space missions is explored. Areas of CPA and HPG design requiring development for space applications are identified. The manner in which acceptance parameters of the CPA and HPG scale with operating parameters of the machines are explored and the types of electrical loads which are compatible with the CPA and HPG are examined. Potential applications including the magnetoplasmadynamic (MPD) thruster, pulsed data transmission, laser ranging, welding and electromagnetic space launch are discussed.
NASA Technical Reports Server (NTRS)
Perry, J. L.
2017-01-01
Contamination of a crewed spacecraft's cabin environment leading to environmental control and life support system (ECLSS) functional capability and operational margin degradation or loss can have an adverse effect on NASA's space exploration mission figures of merit-safety, mission success, effectiveness, and affordability. The role of evaluating the ECLSS's compatibility and cabin environmental impact as a key component of pass trace contaminant control is presented and the technical approach is described in the context of implementing NASA's safety and mission success objectives. Assessment examples are presented for a variety of chemicals used in vehicle systems and experiment hardware for the International Space Station program. The ECLSS compatibility and cabin environmental impact assessment approach, which can be applied to any crewed spacecraft development and operational effort, can provide guidance to crewed spacecraft system and payload developers relative to design criteria assigned ECLSS compatibility and cabin environmental impact ratings can be used by payload and system developers as criteria for ensuring adequate physical and operational containment. In additional to serving as an aid for guiding containment design, the assessments can guide flight rule and procedure development toward protecting the ECLSS as well as approaches for contamination event remediation.
Equipment issues regarding the collection of video data for research
NASA Astrophysics Data System (ADS)
Kung, Rebecca Lippmann; Kung, Peter; Linder, Cedric
2005-12-01
Physics education research increasingly makes use of video data for analysis of student learning and teaching practice. Collection of these data is conceptually simple but execution is often fraught with costly and time-consuming complications. This pragmatic paper discusses the development of systems to record and permanently archive audio and video data in real-time. We focus on a system based upon consumer video DVD recorders, but also give an overview of other technologies and detail issues common to all systems. We detail common yet unexpected complications, particularly with regard to sound quality and compatibility with transcription software. Information specific to fixed and transportable systems, other technology options, and generic and specific equipment recommendations are given in supplemental appendices
Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries.
DeHoff, Paul H; Barrett, Allyson A; Lee, Robert B; Anusavice, Kenneth J
2008-06-01
To test the hypothesis that bilayer ceramic cylinders and spheres can provide valid confirmation of thermal incompatibility stresses predicted by finite element analyses. A commercial core ceramic and an experimental core ceramic were used to fabricate open-ended cylinders and core ceramic spheres. The core cylinders and spheres were veneered with one of four commercial dental ceramics representing four thermally compatible groups and four thermally incompatible groups. Axisymmetric thermal and viscoelastic elements in the ANSYS finite element program were used to calculate temperatures and stresses for each geometry and ceramic combination. This process required a transient heat transfer analysis for each combination to determine input temperatures for the structural model. After fabrication, each specimen was examined visually using fiberoptic transillumination for evidence of cracking. There were 100% failures of the thermally incompatible cylinders while none of the thermally compatible combinations failed. Among the spheres, 100% of the thermally incompatible systems failed, 16% of one of the thermally compatible systems failed, and none of the remaining compatible combinations failed. The calculated stress values were in general agreement with the experimental observations, i.e., low residual stresses for the specimens that did not fail and high residual stresses for the specimens that did fail. Simple screening geometries can be used to identify highly incompatible ceramic combinations, but they do not identify marginally incompatible systems.
Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries
DeHoff, Paul H.; Barrett, Allyson A.; Lee, Robert B.; Anusavice, Kenneth J.
2009-01-01
Objective To test the hypothesis that bilayer ceramic cylinders and spheres can provide valid confirmation of thermal incompatibility stresses predicted by finite element analyses. Methods A commercial core ceramic and an experimental core ceramic were used to fabricate open-ended cylinders and core ceramic spheres. The core cylinders and spheres were veneered with one of four commercial dental ceramics representing four thermally compatible groups and four thermally incompatible groups. Axisymmetric thermal and viscoelastic elements in the ANSYS finite element program were used to calculate temperatures and stresses for each geometry and ceramic combination. This process required a transient heat transfer analysis for each combination to determine input temperatures for the structural model. Results After fabrication, each specimen was examined visually using fiberoptic transillumination for evidence of cracking. There were 100% failures of the thermally incompatible cylinders while none of the thermally compatible combinations failed. Among the spheres, 100% of the thermally incompatible systems failed, 16% of one of the thermally compatible systems failed, and none of the remaining compatible combinations failed. The calculated stress values were in general agreement with the experimental observations, i.e., low residual stresses for the specimens that did not fail and high residual stresses for the specimens that did fail. Significance Simple screening geometries can be used to identify highly incompatible ceramic combinations, but they do not identify marginally incompatible systems. PMID:17949805
A Framework to Manage Information Models
NASA Astrophysics Data System (ADS)
Hughes, J. S.; King, T.; Crichton, D.; Walker, R.; Roberts, A.; Thieman, J.
2008-05-01
The Information Model is the foundation on which an Information System is built. It defines the entities to be processed, their attributes, and the relationships that add meaning. The development and subsequent management of the Information Model is the single most significant factor for the development of a successful information system. A framework of tools has been developed that supports the management of an information model with the rigor typically afforded to software development. This framework provides for evolutionary and collaborative development independent of system implementation choices. Once captured, the modeling information can be exported to common languages for the generation of documentation, application databases, and software code that supports both traditional and semantic web applications. This framework is being successfully used for several science information modeling projects including those for the Planetary Data System (PDS), the International Planetary Data Alliance (IPDA), the National Cancer Institute's Early Detection Research Network (EDRN), and several Consultative Committee for Space Data Systems (CCSDS) projects. The objective of the Space Physics Archive Search and Exchange (SPASE) program is to promote collaboration and coordination of archiving activity for the Space Plasma Physics community and ensure the compatibility of the architectures used for a global distributed system and the individual data centers. Over the past several years, the SPASE data model working group has made great progress in developing the SPASE Data Model and supporting artifacts including a data dictionary, XML Schema, and two ontologies. The authors have captured the SPASE Information Model in this framework. This allows the generation of documentation that presents the SPASE Information Model in object-oriented notation including UML class diagrams and class hierarchies. The modeling information can also be exported to semantic web languages such as OWL and RDF and written to XML Metadata Interchange (XMI) files for import into UML tools.
Development of hazard-compatible building fragility and vulnerability models
Karaca, E.; Luco, N.
2008-01-01
We present a methodology for transforming the structural and non-structural fragility functions in HAZUS into a format that is compatible with conventional seismic hazard analysis information. The methodology makes use of the building capacity (or pushover) curves and related building parameters provided in HAZUS. Instead of the capacity spectrum method applied in HAZUS, building response is estimated by inelastic response history analysis of corresponding single-degree-of-freedom systems under a large number of earthquake records. Statistics of the building response are used with the damage state definitions from HAZUS to derive fragility models conditioned on spectral acceleration values. Using the developed fragility models for structural and nonstructural building components, with corresponding damage state loss ratios from HAZUS, we also derive building vulnerability models relating spectral acceleration to repair costs. Whereas in HAZUS the structural and nonstructural damage states are treated as if they are independent, our vulnerability models are derived assuming "complete" nonstructural damage whenever the structural damage state is complete. We show the effects of considering this dependence on the final vulnerability models. The use of spectral acceleration (at selected vibration periods) as the ground motion intensity parameter, coupled with the careful treatment of uncertainty, makes the new fragility and vulnerability models compatible with conventional seismic hazard curves and hence useful for extensions to probabilistic damage and loss assessment.
Telemedicine and security. Confidentiality, integrity, and availability: a Canadian perspective.
Jennett, P; Watanabe, M; Igras, E; Premkumar, K; Hall, W
1996-01-01
The health care system is undergoing major reform, characterized by organized delivery systems (regionalization, decentralization, devolution, etc); shifts in care delivery sites; changing health provider roles; increasing consumer responsibilities; and accountability. Rapid advances in information technology and telecommunications have led to a new type of information infrastructure which can play a major role in this reform. Compatible health information systems are now being integrated and connected across institutional, regional, and sectorial boundaries. In the near future, these information systems will readily be accessed and shared by health providers, researchers, policy makers, health consumers, and the public. SECURITY is a critical characteristic of any health information system. This paper will address three fields associated with SECURITY: confidentiality, integrity, and availability. These will be defined and examined as they relate to specific aspects of Telemedicine, such as electronic integrated records and clinical databases; electronic transfer of documents; as well as data storage and disposal. The guiding principles, standards, and safeguards being considered and put in place to ensure that telemedicine information intrastructures can protect and benefit all stakeholders' rights and needs in both primary and secondary uses of information will be reviewed. Implemented, proposed, and tested institutional, System, and Network solutions will be discussed; for example, encryption-decryption methods; data transfer standards; individual and terminal access and entry I.D. and password levels; smart card access and PIN number control; data loss prevention strategies; interference alerts; information access keys; algorithm safeguards; and active marketing to users of standards and principles. Issues such as policy, implementation, and ownership will be addressed.
NASA Technical Reports Server (NTRS)
1977-01-01
The microwave scanning beam landing system (MSBLS) is the primary position sensor of the Orbiter's navigation subsystem during the autoland phase of the flight. Portions of the system are discussed with special emphasis placed on potential problem areas as referenced to the Orbiter's mission. Topics discussed include system compatability, system accuracy, and expected RF signal levels. A block and flow diagram of MSBLS system operation is included with a list of special tests required to determine system performance.
GPS Receivers Use-Case Information : GPS Adjacent Band Compatibility Assessment Workshop
DOT National Transportation Integrated Search
2014-09-18
Topics 1. Background. 2. Use Case Template. 3. Description of Submitted UseCases from DOT Extended Pos/Nav Working Group. 4. Utilization of UseCase Information. 5. Request of Information for Additional UseCases from GPS Receiver Manufacturer...
Sensor Networking Testbed with IEEE 1451 Compatibility and Network Performance Monitoring
NASA Technical Reports Server (NTRS)
Gurkan, Deniz; Yuan, X.; Benhaddou, D.; Figueroa, F.; Morris, Jonathan
2007-01-01
Design and implementation of a testbed for testing and verifying IEEE 1451-compatible sensor systems with network performance monitoring is of significant importance. The performance parameters measurement as well as decision support systems implementation will enhance the understanding of sensor systems with plug-and-play capabilities. The paper will present the design aspects for such a testbed environment under development at University of Houston in collaboration with NASA Stennis Space Center - SSST (Smart Sensor System Testbed).
Hampf, Mathias; Gossen, Manfred
2006-09-01
We established a quantitative reporter gene protocol, the P/Rluc assay system, allowing the sequential measurement of Photinus and Renilla luciferase activities from the same extract. Other than comparable commercial reporter assay systems and their noncommercial counterparts, the P/Rluc assay system was formulated under the aspect of full compatibility with standard methods for protein assays. This feature greatly expands the range of applications for assay systems quantifying the expression of multiple luciferase reporters.
Integrating laboratory robots with analytical instruments--must it really be so difficult?
Kramer, G W
1990-09-01
Creating a reliable system from discrete laboratory instruments is often a task fraught with difficulties. While many modern analytical instruments are marvels of detection and data handling, attempts to create automated analytical systems incorporating such instruments are often frustrated by their human-oriented control structures and their egocentricity. The laboratory robot, while fully susceptible to these problems, extends such compatibility issues to the physical dimensions involving sample interchange, manipulation, and event timing. The workcell concept was conceived to describe the procedure and equipment necessary to carry out a single task during sample preparation. This notion can be extended to organize all operations in an automated system. Each workcell, no matter how complex its local repertoire of functions, must be minimally capable of accepting information (commands, data), returning information on demand (status, results), and being started, stopped, and reset by a higher level device. Even the system controller should have a mode where it can be directed by instructions from a higher level.
Domain-independent information extraction in unstructured text
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irwin, N.H.
Extracting information from unstructured text has become an important research area in recent years due to the large amount of text now electronically available. This status report describes the findings and work done during the second year of a two-year Laboratory Directed Research and Development Project. Building on the first-year`s work of identifying important entities, this report details techniques used to group words into semantic categories and to output templates containing selective document content. Using word profiles and category clustering derived during a training run, the time-consuming knowledge-building task can be avoided. Though the output still lacks in completeness whenmore » compared to systems with domain-specific knowledge bases, the results do look promising. The two approaches are compatible and could complement each other within the same system. Domain-independent approaches retain appeal as a system that adapts and learns will soon outpace a system with any amount of a priori knowledge.« less
NASA Technical Reports Server (NTRS)
2005-01-01
The document provides the Human System Integration(HSI) high-level functional C3 HSI requirements for the interface to the pilot. Description includes (1) the information required by the pilot to have knowledge C3 system status, and (2) the control capability needed by the pilot to obtain C3 information. Fundamentally, these requirements provide the candidate C3 technology concepts with the necessary human-related elements to make them compatible with human capabilities and limitations. The results of the analysis describe how C3 operations and functions should interface with the pilot to provide the necessary C3 functionality to the UA-pilot system. Requirements and guidelines for C3 are partitioned into three categories: (1) Pilot-Air Traffic Control (ATC) Voice Communications (2) Pilot-ATC Data Communications, and (3) command and control of the unmanned aircraft (UA). Each requirement is stated and is supported with a rationale and associated reference(s).
Dissociating Simon and affordance compatibility effects: silhouettes and photographs.
Pappas, Zissis
2014-12-01
When a graspable object's handle is oriented to the same side as the response hand, responses are quicker and more accurate than when it is oriented to the opposite side. This effect has been attributed to the affordance of the object's handle (Tucker & Ellis, 1998). Recent findings suggest this effect results instead from an abstract spatial response code (i.e., Simon effect; Cho & Proctor, 2010). However, the stimuli used in these previous studies differ in the amount of object and environmental depth information they contain, which may be critical to conveying an affordance. This information could explain these disparate findings as well as dissociate Simon and affordance compatibility effects. Four experiments demonstrate that the Simon effect results from the absence of this information, as in a silhouette, and the affordance effect results from its presence, as in a photograph. A fifth experiment confirmed that modifying information associated with the affordance, rather than the modification itself, produced the effects observed in the previous experiments. These findings support the following: (a) the internal details of an object and environmental depth can dissociate Simon and affordance compatibility effects, (b) this information is necessary to convey the object's graspable affordance, and (c) the outer shape of the object is not sufficient to elicit an affordance effect. These findings are discussed in relation to the theory of embodied cognition. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bohnhoff-Hlavacek, G.; Pippin, G.; Dursch, H.
1995-04-01
One of the objectives of the LDEF Special Investigation Group (SIG) was to develop a LDEF data base that identifies the experiment objectives and hardware flown, summarizes results and conclusions, and provides a system analysis overview which would include spacecraft design guidelines and space environmental effects. Compiling this information into an easily accessible data base format and making it available to the space community was a major task accomplished by the System and Materials SIG effort beginning in 1991. Included in this document is a short user`s manual for the LDEF Mini-Data Bases. The user`s manual contains pertinent examples frommore » the data base on specifically how to access and work with the LDEF information. Accompanying this document are the mini-data bases on disk.« less
A Compatible Stem Taper-Volume-Weight System For Intensively Managed Fast Growing Loblolly Pine
Yugia Zhang; Bruce E. Borders; Robert L Bailey
2002-01-01
eometry-oriented methodology yielded a compatible taper-volume-weight system of models whose parameters were estimated using data from intensively managed loblolly pine (Pinus taeda L.) plantations in the lower coastal plain of Georgia. Data analysis showed that fertilization has significantly reduced taper (inside and outside bark) on the upper...
A Tol2 Gateway-Compatible Toolbox for the Study of the Nervous System and Neurodegenerative Disease.
Don, Emily K; Formella, Isabel; Badrock, Andrew P; Hall, Thomas E; Morsch, Marco; Hortle, Elinor; Hogan, Alison; Chow, Sharron; Gwee, Serene S L; Stoddart, Jack J; Nicholson, Garth; Chung, Roger; Cole, Nicholas J
2017-02-01
Currently there is a lack in fundamental understanding of disease progression of most neurodegenerative diseases, and, therefore, treatments and preventative measures are limited. Consequently, there is a great need for adaptable, yet robust model systems to both investigate elementary disease mechanisms and discover effective therapeutics. We have generated a Tol2 Gateway-compatible toolbox to study neurodegenerative disorders in zebrafish, which includes promoters for astrocytes, microglia and motor neurons, multiple fluorophores, and compatibility for the introduction of genes of interest or disease-linked genes. This toolbox will advance the rapid and flexible generation of zebrafish models to discover the biology of the nervous system and the disease processes that lead to neurodegeneration.
Sonar Transducer Reliability Improvement Program FY 80.
1980-04-01
transducers has shown that tricresvl Dhosvhate has 2 promise for use where a careful selection of rubber is possible. See Section 2.3. * Information...impedance and are frequently incompatible with the various plastics and rubbers in the transducer. Further research is necessary to find and qualify fill...have excellent or good compatibility with Viton, butyl, chlorobutyl, silicone, and EPDM elastomers. TCP shows marginal compatibility with natural
Assessing a Couple's Relationship and Compatibility Using the MARI[R] Card Test and Mandala Drawings
ERIC Educational Resources Information Center
Frame, Phyllis G.
2006-01-01
This paper illustrates the use of the MARI[R] Card Test, a transpersonal assessment tool which includes archetypal designs and color choices, as well as the drawing of a white and black mandala, or circle picture, for assessing the compatibility of two people in a committed relationship. In an informal pilot research study, 22 couples were given…
78 FR 56839 - Compatibility of Generally Licensed and Exempt Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... 20852. FOR FURTHER INFORMATION CONTACT: Solomon Sahle, Office of Federal and State Materials and...-415- 3781, email: Solomon[email protected] . SUPPLEMENTARY INFORMATION: I. The Petition Section 2.802 of...
International Docking Standard (IDSS) Interface Definition Document (IDD) . E; Revision
NASA Technical Reports Server (NTRS)
Kelly, Sean M.; Cryan, Scott P.
2016-01-01
This International Docking System Standard (IDSS) Interface Definition Document (IDD) is the result of a collaboration by the International Space Station membership to establish a standard docking interface to enable on-orbit crew rescue operations and joint collaborative endeavors utilizing different spacecraft. This IDSS IDD details the physical geometric mating interface and design loads requirements. The physical geometric interface requirements must be strictly followed to ensure physical spacecraft mating compatibility. This includes both defined components and areas that are void of components. The IDD also identifies common design parameters as identified in section 3.0, e.g., docking initial conditions and vehicle mass properties. This information represents a recommended set of design values enveloping a broad set of design reference missions and conditions, which if accommodated in the docking system design, increases the probability of successful docking between different spacecraft. This IDD does not address operational procedures or off-nominal situations, nor does it dictate implementation or design features behind the mating interface. It is the responsibility of the spacecraft developer to perform all hardware verification and validation, and to perform final docking analyses to ensure the needed docking performance and to develop the final certification loads for their application. While there are many other critical requirements needed in the development of a docking system such as fault tolerance, reliability, and environments (e.g. vibration, etc.), it is not the intent of the IDSS IDD to mandate all of these requirements; these requirements must be addressed as part of the specific developer's unique program, spacecraft and mission needs. This approach allows designers the flexibility to design and build docking mechanisms to their unique program needs and requirements. The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions.The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions. The purpose of the IDSS IDD is to provide basic common design parameters to allow developers to independently design compatible docking systems. The IDSS is intended for uses ranging from crewed to autonomous space vehicles, and from Low Earth Orbit (LEO) to deep-space exploration missions.
Applying World Wide Web technology to the study of patients with rare diseases.
de Groen, P C; Barry, J A; Schaller, W J
1998-07-15
Randomized, controlled trials of sporadic diseases are rarely conducted. Recent developments in communication technology, particularly the World Wide Web, allow efficient dissemination and exchange of information. However, software for the identification of patients with a rare disease and subsequent data entry and analysis in a secure Web database are currently not available. To study cholangiocarcinoma, a rare cancer of the bile ducts, we developed a computerized disease tracing system coupled with a database accessible on the Web. The tracing system scans computerized information systems on a daily basis and forwards demographic information on patients with bile duct abnormalities to an electronic mailbox. If informed consent is given, the patient's demographic and preexisting medical information available in medical database servers are electronically forwarded to a UNIX research database. Information from further patient-physician interactions and procedures is also entered into this database. The database is equipped with a Web user interface that allows data entry from various platforms (PC-compatible, Macintosh, and UNIX workstations) anywhere inside or outside our institution. To ensure patient confidentiality and data security, the database includes all security measures required for electronic medical records. The combination of a Web-based disease tracing system and a database has broad applications, particularly for the integration of clinical research within clinical practice and for the coordination of multicenter trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MM Hall
2006-01-31
A major materials selection and qualification issue identified in the Space Materials Plan is the potential for creating materials compatibility problems by combining dissimilar reactor core, Brayton Unit and other power conversion plant materials in a recirculating, inert He/Xe gas loop containing reactive impurity gases. Reported here are results of equilibrium thermochemical analyses that address the compatibility of space nuclear power plant (SNPP) materials in high temperature impure He gas environments. These studies provide early information regarding the constraints that exist for SNPP materials selection and provide guidance for establishing test objectives and environments for SNPP materials qualification testing.
Evolution of uni- and bifactorial sexual compatibility systems in fungi
Nieuwenhuis, B P S; Billiard, S; Vuilleumier, S; Petit, E; Hood, M E; Giraud, T
2013-01-01
Mating systems, that is, whether organisms give rise to progeny by selfing, inbreeding or outcrossing, strongly affect important ecological and evolutionary processes. Large variations in mating systems exist in fungi, allowing the study of their origin and consequences. In fungi, sexual incompatibility is determined by molecular recognition mechanisms, controlled by a single mating-type locus in most unifactorial fungi. In Basidiomycete fungi, however, which include rusts, smuts and mushrooms, a system has evolved in which incompatibility is controlled by two unlinked loci. This bifactorial system probably evolved from a unifactorial system. Multiple independent transitions back to a unifactorial system occurred. It is still unclear what force drove evolution and maintenance of these contrasting inheritance patterns that determine mating compatibility. Here, we give an overview of the evolutionary factors that might have driven the evolution of bifactoriality from a unifactorial system and the transitions back to unifactoriality. Bifactoriality most likely evolved for selfing avoidance. Subsequently, multiallelism at mating-type loci evolved through negative frequency-dependent selection by increasing the chance to find a compatible mate. Unifactoriality then evolved back in some species, possibly because either selfing was favoured or for increasing the chance to find a compatible mate in species with few alleles. Owing to the existence of closely related unifactorial and bifactorial species and the increasing knowledge of the genetic systems of the different mechanisms, Basidiomycetes provide an excellent model for studying the different forces that shape breeding systems. PMID:23838688
Gulsen, Salih
2015-03-15
The first goal in neurosurgery is to protect neural function as long as it is possible. Moreover, while protecting the neural function, a neurosurgeon should extract the maximum amount of tumoral tissue from the tumour region of the brain. So neurosurgery and technological advancement go hand in hand to realize this goal. Using of CT compatible stereotaxy for removing a cranial tumour is to be commended as a cornerstone of these technological advancements. Following CT compatible stereotaxic system applications in neurosurgery, different techniques have taken place in neurosurgical practice. These techniques are magnetic resonance imaging (MRI), MRI compatible stereotaxis, frameless stereotaxy, volumetric stereotaxy, functional MRI, diffusion tensor (DT) imaging techniques (tractography of the white matter), intraoperative MRI and neuronavigation systems. However, to use all of this equipment having these technologies would be impossible because of economic reasons. However, when we correlated this technique with MRI scans of the patients with CT compatible stereotaxy scans, it is possible to provide gross total resection and protect and improve patients' neural functions.
Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes
NASA Technical Reports Server (NTRS)
Thomas, V. L.
1977-01-01
The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.
High-temperature compatibility study of iridium (DOP-26 alloy) with graphite and plutonia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Axler, K.M.; Eash, D.T.
1987-12-01
This report outlines the materials compatibility tests conducted on DOP-26 iridium alloy and carbon. The carbon used was in the form of woven graphite as present in the impact shell used to encase plutonia in nuclear heat sources. In addition, compatibility tests of the DOP-26 alloy with plutonia are described. The reactivity observed in both systems is discussed. 4 refs., 6 figs.
Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes
NASA Technical Reports Server (NTRS)
Thomas, V. L.
1975-01-01
The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.
Cohen, Aina E.; Baxter, Elizabeth L.
2018-01-16
An X-ray data collection grid device is provided that includes a magnetic base that is compatible with robotic sample mounting systems used at synchrotron beamlines, a grid element fixedly attached to the magnetic base, where the grid element includes at least one sealable sample window disposed through a planar synchrotron-compatible material, where the planar synchrotron-compatible material includes at least one automated X-ray positioning and fluid handling robot fiducial mark.
EMC (Electromagnetic Compatibility) System Test and Analysis Interface.
1983-05-01
D- R136 64 EMC (ELECTROARGNETIC COMPATIBILITY) SYSTEM TEST AND V ANALYSIS INTE FACE(J) BOEING CO SEATTLE WA E F BALL ET AL MAY 93 RRDC-TR-83-121...RADC-TR-83- 121 Final Tedical Report May 1963 EMC SYSTEM TEST AND ANAL YSIS INTERFACE_ The Boeing Company E. F. Ball, L. Knutson and B. L...Carlson *. . APPROVE FOR PUBLIC REESEk DIS TRIBUTION ULMTED D IS -ELECTE ,... DEC 20 1983 >- D" c: ROME AIR DEVELOPMENT CENTER * Air Force Systems Command
Wehner, J; Weissler, B; Dueppenbecker, P M; Gebhardt, P; Goldschmidt, B; Schug, D; Kiessling, F; Schulz, V
2015-03-21
PET (positron emission tomography) with its high sensitivity in combination with MRI (magnetic resonance imaging) providing anatomic information with good soft-tissue contrast is considered to be a promising hybrid imaging modality. However, the integration of a PET detector into an MRI system is a challenging task since the MRI system is a sensitive device for external disturbances and provides a harsh environment for electronic devices. Consequently, the PET detector has to be transparent for the MRI system and insensitive to electromagnetic disturbances. Due to the variety of MRI protocols imposing a wide range of requirements regarding the MR-compatibility, an extensive study is mandatory to reliably assess worst-case interference phenomena between the PET detector and the MRI scanner. We have built the first preclinical PET insert, designed for a clinical 3 T MRI, using digital silicon photomultipliers (digital SiPM, type DPC 3200-22, Philips Digital Photon Counting). Since no thorough interference investigation with this new digital sensor has been reported so far, we present in this work such a comprehensive MR-compatibility study. Acceptable distortion of the B0 field homogeneity (volume RMS = 0.08 ppm, peak-to-peak value = 0.71 ppm) has been found for the PET detector installed. The signal-to-noise ratio degradation stays between 2-15% for activities up to 21 MBq. Ghosting artifacts were only found for demanding EPI (echo planar imaging) sequences with read-out gradients in Z direction caused by additional eddy currents originated from the PET detector. On the PET side, interference mainly between the gradient system and the PET detector occurred: extreme gradient tests were executed using synthetic sequences with triangular pulse shape and maximum slew rate. Under this condition, a relative degradation of the energy (⩽10%) and timing (⩽15%) resolution was noticed. However, barely measurable performance deterioration occurred when morphological MRI protocols are conducted certifying that the overall PET performance parameters remain unharmed.
Freimuth, Robert R; Schauer, Michael W; Lodha, Preeti; Govindrao, Poornima; Nagarajan, Rakesh; Chute, Christopher G
2008-11-06
The caBIG Compatibility Review System (CRS) is a web-based application to support compatibility reviews, which certify that software applications that pass the review meet a specific set of criteria that allow them to interoperate. The CRS contains workflows that support both semantic and syntactic reviews, which are performed by the caBIG Vocabularies and Common Data Elements (VCDE) and Architecture workspaces, respectively. The CRS increases the efficiency of compatibility reviews by reducing administrative overhead and it improves uniformity by ensuring that each review is conducted according to a standard process. The CRS provides metrics that allow the review team to evaluate the level of data element reuse in an application, a first step towards quantifying the extent of harmonization between applications. Finally, functionality is being added that will provide automated validation of checklist criteria, which will further simplify the review process.
Trimble Use Case Information : A Presentation to DOT Adjacent Band Compatibility Workshop #2
DOT National Transportation Integrated Search
2014-12-04
Trimble Use Case Overview: Heavy Civil Construction - Planning, Designing, Building and Operating: Enhanced information, decision making and control across the entire project lifecycle, generating benefits including: - Faster Completion - Reduced Fue...
Virtual shelves in a digital library: a framework for access to networked information sources.
Patrick, T B; Springer, G K; Mitchell, J A; Sievert, M E
1995-01-01
OBJECTIVE: Develop a framework for collections-based access to networked information sources that addresses the problem of location-dependent access to information sources. DESIGN: This framework uses a metaphor of a virtual shelf. A virtual shelf is a general-purpose server that is dedicated to a particular information subject class. The identifier of one of these servers identifies its subject class. Location-independent call numbers are assigned to information sources. Call numbers are based on standard vocabulary codes. The call numbers are first mapped to the location-independent identifiers of virtual shelves. When access to an information resource is required, a location directory provides a second mapping of these location-independent server identifiers to actual network locations. RESULTS: The framework has been implemented in two different systems. One system is based on the Open System Foundation/Distributed Computing Environment and the other is based on the World Wide Web. CONCLUSIONS: This framework applies in new ways traditional methods of library classification and cataloging. It is compatible with two traditional styles of selecting information searching and browsing. Traditional methods may be combined with new paradigms of information searching that will be able to take advantage of the special properties of digital information. Cooperation between the library-informational science community and the informatics community can provide a means for a continuing application of the knowledge and techniques of library science to the new problems of networked information sources. PMID:8581554
Self-Calibrating, Variable-Flow Pumping System
NASA Technical Reports Server (NTRS)
Walls, Joe T.
1994-01-01
Pumping system provides accurate, controlled flows of two chemical liquids mixed in spray head and react to form rigid or flexible polyurethane or polyisocyanurate foam. Compatible with currently used polyurethane-based coating materials and gas-bubble-forming agents (called "blowing agents" in industry) and expected to be compatible with materials that used in near future. Handles environmentally acceptable substitutes for chlorofluorocarbon foaming agents.
Device to color modulate a stationary light beam gives high intensity
NASA Technical Reports Server (NTRS)
Gantz, W. A.
1966-01-01
Signal controlled system color modulates a beam of light while also providing high intensity and a stationary beam, either collimated or focused. The color modulation acquired by the presented system can be compatible with any color film by employing color filters formed to provide a color wedge having a color distribution compatible with the films color sensitivity.
EMC (Electromagnetic Compatibility) Standards Handbook. Revision 4,
1982-11-01
report was prepared by the lIT Research Institute as part of AF Project 649E under Contract F-19628-80-C-0042 with the Electronic Systems Division of...the Air Pbrce Systems Command in support of the DoD Electromagnetic Compatibility Analysis Center, Annapolis, Maryland. This report has been reviewed...3-1 "JVDE Organizations .. .0 . . . . . . . . . . . . . . . . . . . . . 3 1 VDE Testing Station
Software engineering and data management for automated payload experiment tool
NASA Technical Reports Server (NTRS)
Maddux, Gary A.; Provancha, Anna; Chattam, David
1994-01-01
The Microgravity Projects Office identified a need to develop a software package that will lead experiment developers through the development planning process, obtain necessary information, establish an electronic data exchange avenue, and allow easier manipulation/reformatting of the collected information. An MS-DOS compatible software package called the Automated Payload Experiment Tool (APET) has been developed and delivered. The objective of this task is to expand on the results of the APET work previously performed by University of Alabama in Huntsville (UAH) and provide versions of the software in a Macintosh and Windows compatible format. Appendix 1 science requirements document (SRD) Users Manual is attached.
Landowner’s Guide for Compatible Use of BPA Rights-of-Way
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Keeping transmission lines safe and reliable is a critical priority for the Bonneville Power Administration. The key element in achieving those objectives is BPA’s ability to construct, operate and maintain its transmission lines and rights-of-way — the area under and around the lines. You can help BPA keep these rights-of-way clear of trees, brush and structures that could affect the safety or reliability of the transmission system. Prior to planting, digging, or constructing within BPA’s rights-of-way, fill out BPA’s Land Use Application Form. The information you provide on the application helps BPA understand your proposed use and the potential impactsmore » to public safety, and the safety of our crews. BPA also reviews the application to determine whether a proposed use of land is compatible with the construction, operation and maintenance of BPA transmission lines. Coordinating with BPA early in your planning process can keep you safe and avoid wasting time and money.« less
Oshida, Yoshiki; Tuna, Elif B.; Aktören, Oya; Gençay, Koray
2010-01-01
Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s) in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities. PMID:20480036
An MR-compatible neonatal incubator.
Paley, M N J; Hart, A R; Lait, M; Griffiths, P D
2012-07-01
To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost.
An MR-compatible neonatal incubator
Paley, M N J; Hart, A R; Lait, M; Griffiths, P D
2012-01-01
Objectives To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. Methods The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Results Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. Conclusion The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost. PMID:22167517
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains appendices for the following: Rocky Flats Plant and Idaho National Engineering Laboratory waste process information; TRUPACT-II content codes (TRUCON); TRUPACT-II chemical list; chemical compatibility analysis for Rocky Flats Plant waste forms; chemical compatibility analysis for waste forms across all sites; TRU mixed waste characterization database; hazardous constituents of Rocky Flats Transuranic waste; summary of waste components in TRU waste sampling program at INEL; TRU waste sampling program; and waste analysis data.
NASA Technical Reports Server (NTRS)
Guarro, Sergio B.
2010-01-01
This report validates and documents the detailed features and practical application of the framework for software intensive digital systems risk assessment and risk-informed safety assurance presented in the NASA PRA Procedures Guide for Managers and Practitioner. This framework, called herein the "Context-based Software Risk Model" (CSRM), enables the assessment of the contribution of software and software-intensive digital systems to overall system risk, in a manner which is entirely compatible and integrated with the format of a "standard" Probabilistic Risk Assessment (PRA), as currently documented and applied for NASA missions and applications. The CSRM also provides a risk-informed path and criteria for conducting organized and systematic digital system and software testing so that, within this risk-informed paradigm, the achievement of a quantitatively defined level of safety and mission success assurance may be targeted and demonstrated. The framework is based on the concept of context-dependent software risk scenarios and on the modeling of such scenarios via the use of traditional PRA techniques - i.e., event trees and fault trees - in combination with more advanced modeling devices such as the Dynamic Flowgraph Methodology (DFM) or other dynamic logic-modeling representations. The scenarios can be synthesized and quantified in a conditional logic and probabilistic formulation. The application of the CSRM method documented in this report refers to the MiniAERCam system designed and developed by the NASA Johnson Space Center.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.
Pemberton, A J; Sommerfeldt, A D; Wood, C A; Flint, H C; Noble, L R; Clarke, K R; Bishop, J D D
2004-05-01
The importance of sexual compatibility between mates has only recently been realized in zoological research into sexual selection, yet its study has been central to botanical research for many decades. The reproductive characteristics of remote mating, an absence of precopulatory mate screening, internal fertilization and embryonic brooding are shared between passively pollinated plants and a phylogenetically diverse group of sessile aquatic invertebrates. Here, we further characterize the sexual compatibility system of one such invertebrate, the colonial ascidian Diplosoma listerianum. All 66 reciprocal pairings of 12 genetic individuals were carried out. Fecundities of crosses varied widely and suggested a continuous scale of sexual compatibility. Of the 11 animals from the same population c. 40% of crosses were completely incompatible with a further c. 20% having obvious partial compatibility (reduced fecundity). We are unaware of other studies documenting such high levels of sexual incompatibility in unrelated individuals. RAPD fingerprinting was used to estimate relatedness among the 12 individuals after a known pedigree was successfully reconstructed to validate the technique. In contrast to previous results, no correlation between genetic similarity and sexual compatibility was detected. The blocking of many genotypes of sperm is expected to severely modify realized paternity away from 'fair raffle' expectations and probably reduce levels of intra-brood genetic diversity in this obligatorily promiscuous mating system. One adaptive benefit may be to reduce the bombardment of the female reproductive system by outcrossed sperm with conflicting evolutionary interests, so as to maintain female control of somatic : gametic investment.
NASA Astrophysics Data System (ADS)
Zajicek, J.; Burian, M.; Soukup, P.; Novak, V.; Macko, M.; Jakubek, J.
2017-01-01
Multimodal medical imaging based on Magnetic Resonance is mainly combinated with one of the scintigraphic method like PET or SPECT. These methods provide functional information whereas magnetic resonance imaging provides high spatial resolution of anatomical information or complementary functional information. Fusion of imaging modalities allows researchers to obtain complimentary information in a single measurement. The combination of MRI with SPECT is still relatively new and challenging in many ways. The main complication of using SPECT in MRI systems is the presence of a high magnetic field therefore (ferro)magnetic materials have to be eliminated. Furthermore the application of radiofrequency fields within the MR gantry does not allow for the use of conductive structures such as the common heavy metal collimators. This work presents design and construction of an experimental MRI-SPECT insert system and its initial tests. This unique insert system consists of an MR-compatible SPECT setup with CdTe pixelated sensors Timepix tungsten collimators and a radiofrequency coil. Measurements were performed on a gelatine and tissue phantom with an embedded radioisotopic source (57Co 122 keV γ ray) inside the RF coil by the Bruker BioSpec 47/20 (4.7 T) MR animal scanner. The project was performed in the framework of the Medipix Collaboration.
Novel agrochemical conjugates with self-assembling behaviour.
Liu, Qingtao; Graham, Bim; Hawley, Adrian; Dong, Yao-Da; Boyd, Ben J
2018-02-15
That conjugation of agrichemicals to pro-assembly hydrophobic moieties will enable enhanced compatibility and loading with host lyotropic liquid crystalline carrier matrix, and potentially self-assemble in their own right in aqueous environments. A series of lipid-like agrochemical-conjugates were synthesized using specific amphiphilic entities conjugated onto the agrochemicals, picloram and 2,4-dichlorophenoxyacetic acid (2,4-D). The self-assembly behaviour and compatibility of the novel entities when incorporated into phytantriol and monoolein-based liquid crystalline systems were examined using small angle X-ray scattering, cryo-TEM and polarized optical microscopy. Compared to agrochemical-conjugates with simple alkyl ester groups, the esterification of the agrochemicals with amphiphilic groups such as phytantriol and monoolein led to greater structural compatibility and consequently a greater loading of the agrochemicals in the liquid crystalline systems without destabilizing phase structure. Picloram-monoolein and picloram-monoelaidin can self-assemble to form lamellar structures in water. However, certain agrochemical-conjugates such as picloram-monoelaidin and picloram-PEGn-oleate showed poor compatibility with liquid crystalline systems, resulting in phase separation. Copyright © 2017 Elsevier Inc. All rights reserved.
Streamlining ITS planning : identifying common ITS needs : national ITS architecture
DOT National Transportation Integrated Search
1999-01-01
This brochure gives an overview of the National Intelligent Transportation Systems (ITS) Architecture. The objects of the program include: to aid in the purchase of compatible equipment and services; to guide multilevel efforts in implementing compat...
Bacterial toxicity/compatibility of platinum nanospheres, nanocuboids and nanoflowers
Gopal, Judy; Hasan, Nazim; Manikandan, M.; Wu, Hui-Fen
2013-01-01
For the first time, we have investigated the bacterial toxicity or compatibility properties of Pt nanoparticles (NPs) with different sizes (P1, P2, P3, P4 and P5). The bacterio-toxic or compatible properties of these five different sized Pt NPs with the clinical pathogen, Pseudomonas aeruginosa were explored by many analytical methods such as the conventional plate count method, matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS), fluorescence microscopy and fluorescence sensoring techniques. The results revealed that the 1–3 nm sized (P1 and P2) Pt NPs showed bacterio-toxic properties while the 4–21 nm (P3, P4 and P5) Pt NPs exhibited bacterio-compatible properties. This is the first study which reports the bacterial toxicity of Pt NPs. The information released from this study is significantly important to future clinical, medical, biological and biomedical applications of Pt NPs. PMID:23405274
Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements
NASA Astrophysics Data System (ADS)
Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey
2017-12-01
Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.
Continuation of research in software for space operations support
NASA Technical Reports Server (NTRS)
Collier, Mark D.
1989-01-01
Software technologies relevant to workstation executives are discussed. Evaluations of problems, potential or otherwise, seen with IBM's Workstation Executive (WEX) 2.5 preliminary design and applicable portions of the 2.5 critical design are presented. Diverse graphics requirements of the Johnson Space Center's Mission Control Center Upgrade (MCCU) are also discussed. The key is to use tools that are portable, compatible with the X window system, and best suited to the requirements of the associated application. This will include a User Interface Language (UIL), an interactive display builder, and a graphic plotting/modeling system. Work sheets are provided for POSIX 1003.4 real-time extensions and the requirements for the Center's automated information systems security plan, referred to as POSIX 1003.6, are discussed.
Organo-metallic elements for associative information processing
NASA Astrophysics Data System (ADS)
Potember, Richard S.; Poehler, Theodore O.
1989-01-01
In the three years of the program we have: (1) built and tested a 4 bit element matrix device for possible use in high density content-addressable memories systems; (2) established a test and evaluation laboratory to examine optical materials for nonlinear effects, saturable absorption, harmonic generation and photochromism; (3) successfully designed, constructed and operated a codeposition processing system that enables organic materials to be deposited on a variety of substrates to produce optical grade coatings and films. This system is also compatible with other traditional microelectronic techniques; (4) used the sol-gel process with colloidal AgTCNQ to fabricate high speed photochromic switches; (5) develop and applied for patent coverage to make VO2 optical switching materials via the sol-gel processing using vanadium (IV) alkoxide compounds.
Roy, Somak; Durso, Mary Beth; Wald, Abigail; Nikiforov, Yuri E; Nikiforova, Marina N
2014-01-01
A wide repertoire of bioinformatics applications exist for next-generation sequencing data analysis; however, certain requirements of the clinical molecular laboratory limit their use: i) comprehensive report generation, ii) compatibility with existing laboratory information systems and computer operating system, iii) knowledgebase development, iv) quality management, and v) data security. SeqReporter is a web-based application developed using ASP.NET framework version 4.0. The client-side was designed using HTML5, CSS3, and Javascript. The server-side processing (VB.NET) relied on interaction with a customized SQL server 2008 R2 database. Overall, 104 cases (1062 variant calls) were analyzed by SeqReporter. Each variant call was classified into one of five report levels: i) known clinical significance, ii) uncertain clinical significance, iii) pending pathologists' review, iv) synonymous and deep intronic, and v) platform and panel-specific sequence errors. SeqReporter correctly annotated and classified 99.9% (859 of 860) of sequence variants, including 68.7% synonymous single-nucleotide variants, 28.3% nonsynonymous single-nucleotide variants, 1.7% insertions, and 1.3% deletions. One variant of potential clinical significance was re-classified after pathologist review. Laboratory information system-compatible clinical reports were generated automatically. SeqReporter also facilitated quality management activities. SeqReporter is an example of a customized and well-designed informatics solution to optimize and automate the downstream analysis of clinical next-generation sequencing data. We propose it as a model that may envisage the development of a comprehensive clinical informatics solution. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
EEG monitoring of a free-swimming diver at a working depth of 15 meters.
NASA Technical Reports Server (NTRS)
Zweizig, J. R.; Adey, W. R.; Hanley, J.; Hahn, P. M.; Pilmanis, A. A.; Given, R. R.; Cockett, A. T. K.
1972-01-01
Feasibility has been shown for underwater transmission of physiological signals, using frequency modulation of carriers transmitted by return-current-density methods, as part of a personal biotelemetry system. In the prototype system, a standard IRIG subcarrier frequency (2300 Hz) was used. Power requirements, antenna design, and signal attenuation are compatible with free-ranging diving activity at distances up to 15 meters from the receiver. Extrapolation from this study and further developments are expected to substantially increase the range. Advantages of this system include subcarrier compatibility with standard IRIG demodulators using channels 1 through 10, the absence of highly specialized antenna requirements, and reasonable attenuation characteristics for transmission through the turbidity of typical seawater. Moreover, the system would not appear to be depth limited, and to be compatible with use of high-powered transponders of the same type for long-distance transmission, with or without further encoding.
Techniques for digital enhancement of Landsat MSS data using an Apple II+ microcomputer
NASA Technical Reports Server (NTRS)
Harrington, J. A., Jr.; Cartin, K. F.
1984-01-01
The information provided by remotely sensed data collected from orbiting platforms has been useful in many research fields. Particularly convenient for evaluation are generally digital data stored on computer compatible tapes (CCT's). The major advantages of CCT's are the quality of the data and the accessibility to computer manipulation. Minicomputer systems are widely used for the required computer processing operations. However, microprocessor-related technological advances make it now possible to process CCT data with computing systems which can be obtained at a much lower price than minicomputer systems. A detailed description is provided of the design considerations of a microcomputer-based Digital Image Analysis System (DIAS). Particular attention is given to the algorithms which are incorporated for eighter edge enhancement or smoothing Landsat multispectral scanner data.
Transient Turbine Engine Modeling with Hardware-in-the-Loop Power Extraction (PREPRINT)
2008-07-01
Furthermore, it must be compatible with a real - time operating system that is capable of running the simulation. For some models, especially those that use...problem of interfacing the engine/control model to a real - time operating system and associated lab hardware becomes a problem of interfacing these...model in real-time. This requires the use of a real - time operating system and a compatible I/O (input/output) board. Figure 1 illustrates the HIL
Technology Assessment of the DACS/MERADCOM Prestaged Ammunition Loading System (PALS) Concept Study.
1980-08-01
American Railroads (AAR) and Coast 1-2 Arthurl) little.lnc - Guard (CC) regulations for the shipment of ammunition. The system must be compatible with...to meet Association of American Railroads (AAR) and Coast Guard (CC) regulations for the shipment of ammunition. The system must be compatible with...unloaded u ler field conditions? (4) Can the PALS meet AA and CC regulations for the safe shipment of ammunition in commercial cargo containers? (5
Estimating aquifer transmissivity from specific capacity using MATLAB.
McLin, Stephen G
2005-01-01
Historically, specific capacity information has been used to calculate aquifer transmissivity when pumping test data are unavailable. This paper presents a simple computer program written in the MATLAB programming language that estimates transmissivity from specific capacity data while correcting for aquifer partial penetration and well efficiency. The program graphically plots transmissivity as a function of these factors so that the user can visually estimate their relative importance in a particular application. The program is compatible with any computer operating system running MATLAB, including Windows, Macintosh OS, Linux, and Unix. Two simple examples illustrate program usage.
A simple 5-DoF MR-compatible motion signal measurement system.
Chung, Soon-Cheol; Kim, Hyung-Sik; Yang, Jae-Woong; Lee, Su-Jeong; Choi, Mi-Hyun; Kim, Ji-Hye; Yeon, Hong-Won; Park, Jang-Yeon; Yi, Jeong-Han; Tack, Gye-Rae
2011-09-01
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal was modulated to an optic signal using pulse width modulation, and the modulated optic signal was transmitted outside the MR shield room using a high-intensity light-emitting diode and an optic cable. The motion signal was recorded on a PC by demodulating the transmitted optic signal into an electric signal. Various kinematic variables, such as angle, acceleration, velocity, and jerk, can be measured or calculated by using the motion measurement system developed here. This system also enables motion tracking by extracting the position information from the motion signals. It was verified that MR images and motion signals could reliably be measured simultaneously.
Kjelle, Elin; Lysdahl, Kristin Bakke; Olerud, Hilde Merete; Myklebust, Aud Mette
2018-04-25
In order to meet the future challenges posed by ageing populations, new technology, telemedicine and a more personalized healthcare system are needed. Earlier research has shown mobile radiography services to be highly beneficial for nursing home residents in addition to being cost-effective. Despite the benefits, mobile radiography services are uncommon in Europe and Norway. The purpose of this study was to explore success criteria and barriers in the process of implementing mobile radiography services, from the point of view of the hospital and municipal managers. Eleven semi-structured interviews were conducted with managers from five hospitals and six municipalities in Norway where mobile radiography services had been implemented. Core issues in the interview guide were barriers and facilitators in the different phases of implementation. The framework method for thematic analysis was used for analysing the data inductively in a research team. Five main categories were developed through the success criteria and barriers experienced by the participants: national health policy, regional and municipal policy and conditions, inter-organizational implementation projects, experienced outcome, and professional skills and personal characteristics. The categories were allocated into three higher-order classifications: macro, meso and micro levels. The main barriers experienced by the managers were financial, procedural and structural. In particular, the reimbursement system, lack of management across healthcare levels and the lack of compatible information systems acted as barriers. The main facilitators were external funding, enthusiastic individuals in the organizations and good collaboration between hospitals and municipalities. The managers experienced financial, structural and procedural barriers. The main success criteria in the process were external funding, and the support and engagement from the individuals in the organizations. This commitment was mainly facilitated by the intuitive appeal of mobile radiography. Changes in healthcare management and in the financial system might facilitate services across healthcare levels. In addition, compatible information systems across healthcare levels are needed in order to facilitate the use of new technology and mobile services.
Guo, Xueshi; Li, Xiaoying; Liu, Nannan; Ou, Z Y
2016-07-26
One of the important functions in a communication network is the distribution of information. It is not a problem to accomplish this in a classical system since classical information can be copied at will. However, challenges arise in quantum system because extra quantum noise is often added when the information content of a quantum state is distributed to various users. Here, we experimentally demonstrate a quantum information tap by using a fiber optical parametric amplifier (FOPA) with correlated inputs, whose noise is reduced by the destructive quantum interference through quantum entanglement between the signal and the idler input fields. By measuring the noise figure of the FOPA and comparing with a regular FOPA, we observe an improvement of 0.7 ± 0.1 dB and 0.84 ± 0.09 dB from the signal and idler outputs, respectively. When the low noise FOPA functions as an information splitter, the device has a total information transfer coefficient of Ts+Ti = 1.5 ± 0.2, which is greater than the classical limit of 1. Moreover, this fiber based device works at the 1550 nm telecom band, so it is compatible with the current fiber-optical network for quantum information distribution.
Levy, Sheri R.; London, Bonita; Lobel, Marci; Bazile, Cartney
2014-01-01
Women continue to face gender-related challenges in the medical field in places around the world where it has traditionally been male-dominated, including in the U.S. In an online experimental study with women attending a mid-sized public university in the Northeastern U.S. (N= 55) who were interested in pursuing a pre-medical track (being pre-med) as undergraduates, we explored the mechanisms involved in undergraduate women’s pursuit of a career as a physician, focusing on three factors: exposure to successful female physician role models, perceived identity compatibility between being a woman and being pre-med, and sense of belonging in pre-med. Participants were randomly assigned to an experimental condition in which they were exposed to information about successful female physicians, or to a control condition in which no information about female physicians was provided. First, as hypothesized, participants exposed to successful female physicians reported higher perceived identity compatibility, sense of belonging, and interest in a medical career compared to those in the control condition. Second, also as hypothesized, perceived identity compatibility mediated the effect of role models on sense of belonging, and sense of belonging mediated the relationship between perceived identity compatibility and interest in a medical career. This study highlights three key factors in women’s pursuit of a career as a physician and the process through which these factors may operate. Findings support the use of role models to set a positive psychosocial process in motion that can support women’s persistence in medicine. PMID:24497671
Enhanced training using the life support for trauma and transport (LSTAT)
NASA Astrophysics Data System (ADS)
Hanson, Matthew E.; Toth, Louis S.; White, William H.
1999-07-01
The Life Support for Trauma and Transport (LSTAT) is an intensive care unit (ICU) in a 'stretcher' only 5 inches thick. LSTAT is a portable intensive care system which integrates state-of-the-art, commercial-off-the-shelf, hospital grade ICU devices into a single patient resuscitation, stabilization, evacuation, and surgical platform. LSTAT's current and evolving attributes include compact volume, low weight, integrated devices and subsystems, ergonomic patient-caregiver interface, patient and system information system, near-universal power interface, patient- caregiver hazardous environment isolation, and extensive evacuation vehicle interface compatibility. Although the LSTAT system architecture was established primarily to support diagnosis, monitoring and telemedicine consulting, the information architecture and communications suite can also support hosting training experiences and scenarios. The training scenario capabilities and features include: (1) moving training out to the field, (2) facilitating distributed training, (3) off-setting training with remote experts (or potentially embedded expert systems), and (4) facilitating training-by-simulation. Equipping the caregiver via such enhanced equipment and training should ultimately translate into better care for the patient.
Addressable configurations of DNA nanostructures for rewritable memory.
Chandrasekaran, Arun Richard; Levchenko, Oksana; Patel, Dhruv S; MacIsaac, Molly; Halvorsen, Ken
2017-11-02
DNA serves as nature's information storage molecule, and has been the primary focus of engineered systems for biological computing and data storage. Here we combine recent efforts in DNA self-assembly and toehold-mediated strand displacement to develop a rewritable multi-bit DNA memory system. The system operates by encoding information in distinct and reversible conformations of a DNA nanoswitch and decoding by gel electrophoresis. We demonstrate a 5-bit system capable of writing, erasing, and rewriting binary representations of alphanumeric symbols, as well as compatibility with 'OR' and 'AND' logic operations. Our strategy is simple to implement, requiring only a single mixing step at room temperature for each operation and standard gel electrophoresis to read the data. We envision such systems could find use in covert product labeling and barcoding, as well as secure messaging and authentication when combined with previously developed encryption strategies. Ultimately, this type of memory has exciting potential in biomedical sciences as data storage can be coupled to sensing of biological molecules. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Application of Inkjet-Printing Technology to Micro-Electro-Mechanical Systems
2014-05-01
dimensional MEMS using inkjet-printing metal nanoparticles and demonstrated resonant inductive coils, electrostatic-drive motors, and electrothermal actuators...telecommunications base stataions, satellites and defense systems [48]. 1.4 Printed Microshell Encapsulation In this thesis, a fabrication process was...that the solvent of the ink needs to be heat-compatible, which may limit the range of solvent that can be used. For example, most bio -compatible
Advanced Alarm Systems: Revision of Guidance and Its Technical Basis
2000-11-01
was required to generalize from the unique aspects of individual experiments and studies to actual applications in the workplace . This is because...types of equipment used). For example , laboratory experiments often do not involve tasks of the complexity of NPP operations, and most experiments do...Cognitive Compatibility, Situation Awareness, Task Compatibility, and Timeliness. Figure 3.3 Example of an alarm system design review guideline Each
MR-Compatible Integrated Eye Tracking System
2016-03-10
SECURITY CLASSIFICATION OF: This instrumentation grant was used to purchase state-of-the-art, high-resolution video eye tracker that can be used to...P.O. Box 12211 Research Triangle Park, NC 27709-2211 video eye tracking, eye movments, visual search; camouflage-breaking REPORT DOCUMENTATION PAGE...Report: MR-Compatible Integrated Eye Tracking System Report Title This instrumentation grant was used to purchase state-of-the-art, high-resolution video
Electromagnetic compatibility of PLC adapters for in-home/domestic networks
NASA Astrophysics Data System (ADS)
Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek
2018-01-01
The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].
NASA Technical Reports Server (NTRS)
Herald, Stephen D.; Frisby, Paul M.; Davis, Samuel Eddie
2009-01-01
Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to demonstrate the importance of the metal chosen and relative percentage of filler. General conclusions on the oxygen compatibility of this formulation are drawn, with an emphasis on comparing and contrasting the materials performance to the performance of the current state-of-the-art oxygen compatible polymers.
Alternative Work Schedules: Designing Compatible Work Systems
ERIC Educational Resources Information Center
Steen, Pamela L.
1977-01-01
Attempts to improve the quality of working life through changes in environmental factors, such as flexible hours, are likely to bring limited and short-term advantages unless the work process itself is well-designed and compatible with the environmental changes. (Author/LBH)
Quantum interference in heterogeneous superconducting-photonic circuits on a silicon chip.
Schuck, C; Guo, X; Fan, L; Ma, X; Poot, M; Tang, H X
2016-01-21
Quantum information processing holds great promise for communicating and computing data efficiently. However, scaling current photonic implementation approaches to larger system size remains an outstanding challenge for realizing disruptive quantum technology. Two main ingredients of quantum information processors are quantum interference and single-photon detectors. Here we develop a hybrid superconducting-photonic circuit system to show how these elements can be combined in a scalable fashion on a silicon chip. We demonstrate the suitability of this approach for integrated quantum optics by interfering and detecting photon pairs directly on the chip with waveguide-coupled single-photon detectors. Using a directional coupler implemented with silicon nitride nanophotonic waveguides, we observe 97% interference visibility when measuring photon statistics with two monolithically integrated superconducting single-photon detectors. The photonic circuit and detector fabrication processes are compatible with standard semiconductor thin-film technology, making it possible to implement more complex and larger scale quantum photonic circuits on silicon chips.
Hwang, Wonil; Salvendy, Gavriel
2005-06-10
Ontologies, as a possible element of organizational memory information systems, appear to support organizational learning. Ontology tools can be used to share knowledge among the members of an organization. However, current ontology-viewing user interfaces of ontology tools do not fully support organizational learning, because most of them lack proper history representation in their display. In this study, a conceptual model was developed that emphasized the role of ontology in the organizational learning cycle and explored the integration of history representation in the ontology display. Based on the experimental results from a split-plot design with 30 participants, two conclusions were derived: first, appropriately selected history representations in the ontology display help users to identify changes in the ontologies; and second, compatibility between types of ontology display and history representation is more important than ontology display and history representation in themselves.
Neuromorphic photonic networks using silicon photonic weight banks.
Tait, Alexander N; de Lima, Thomas Ferreira; Zhou, Ellen; Wu, Allie X; Nahmias, Mitchell A; Shastri, Bhavin J; Prucnal, Paul R
2017-08-07
Photonic systems for high-performance information processing have attracted renewed interest. Neuromorphic silicon photonics has the potential to integrate processing functions that vastly exceed the capabilities of electronics. We report first observations of a recurrent silicon photonic neural network, in which connections are configured by microring weight banks. A mathematical isomorphism between the silicon photonic circuit and a continuous neural network model is demonstrated through dynamical bifurcation analysis. Exploiting this isomorphism, a simulated 24-node silicon photonic neural network is programmed using "neural compiler" to solve a differential system emulation task. A 294-fold acceleration against a conventional benchmark is predicted. We also propose and derive power consumption analysis for modulator-class neurons that, as opposed to laser-class neurons, are compatible with silicon photonic platforms. At increased scale, Neuromorphic silicon photonics could access new regimes of ultrafast information processing for radio, control, and scientific computing.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-28
... Activities: Requests for Comments; Clearance of Renewed Approval of Information Collection: Airport Noise... information collection. The respondents are those airport operators voluntarily submitting noise exposure maps and noise compatibility programs to the FAA for review and approval. DATES: Written comments should be...
What's she doing in the kitchen? Context helps when actions are hard to recognize.
Wurm, Moritz F; Schubotz, Ricarda I
2017-04-01
Specific spatial environments are often indicative of where certain actions may take place: In kitchens we prepare food, and in bathrooms we engage in personal hygiene, but not vice versa. In action recognition, contextual cues may constrain an observer's expectations toward actions that are more strongly associated with a particular context than others. Such cues should become particularly helpful when the action itself is difficult to recognize. However, to date only easily identifiable actions were investigated, and the effects of context on recognition were rather interfering than facilitatory. To test whether context also facilitates action recognition, we measured recognition performance of hardly identifiable actions that took place in compatible, incompatible, and neutral contextual settings. Action information was degraded by pixelizing the area of the object manipulation while the room in which the action took place remained fully visible. We found significantly higher accuracy for actions that took place in compatible compared to incompatible and neutral settings, indicating facilitation. Additionally, action recognition was slower in incompatible settings than in compatible and neutral settings, indicating interference. Together, our findings demonstrate that contextual information is effectively exploited during action observation, in particular when visual information about the action itself is sparse. Differential effects on speed and accuracy suggest that contexts modulate action recognition at different levels of processing. Our findings emphasize the importance of contextual information in comprehensive, ecologically valid models of action recognition.
TruSeq Stranded mRNA and Total RNA Sample Preparation Kits
Total RNA-Seq enabled by ribosomal RNA (rRNA) reduction is compatible with formalin-fixed paraffin embedded (FFPE) samples, which contain potentially critical biological information. The family of TruSeq Stranded Total RNA sample preparation kits provides a unique combination of unmatched data quality for both mRNA and whole-transcriptome analyses, robust interrogation of both standard and low-quality samples and workflows compatible with a wide range of study designs.
Hägerström, Helene; Edsman, Katarina; Strømme, Maria
2003-09-01
This interdisciplinary work demonstrates how low-frequency dielectric spectroscopy, a technique that is frequently used within physics, can be used to assess the possibilities of intimate surface contact between a polymer gel and mucous tissue, which is generally considered to be the first step in the mucoadhesion process. The dielectric responses of five different gels, of freshly excised porcine nasal mucosa and of systems made by combining the two were measured. All spectra were modeled by a Randles electric circuit containing a diffusion element, a barrier resistance in parallel with a capacitance, and a high-frequency resistance. The results were used to create a measure of the compatibility between the gel and the mucus, which we have named the compatibility factor. Thus, the compatibility factor provides us with a measure of the ease with which a charged species passes the interface between a gel and the mucus layer. The compatibility factor is calculated from the high frequency (kHz region) response of the gel, of the mucosa, and of the combined system. The two highest compatibility factors in this study were obtained for gels based on crosslinked poly(acrylic acid) and chitosan, which was in agreement with the results from mucoadhesion measurements that were performed using a tensile strength method. Copyright 2003 Wiley-Liss, Inc. and the American Pharmacists Association
Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom.
Tavallaei, M A; Lavdas, M K; Gelman, D; Drangova, M
2016-08-01
To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist's input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of [Formula: see text]1 mm in axial catheter motion replication over 30 mm of travel and [Formula: see text] for radial catheter motion replication over [Formula: see text]. The worst case SNR drop was observed to be [Formula: see text]3 %; the robot did not introduce any artifacts in the MR images. An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality.
Behmer, Lawrence P; Fournier, Lisa R
2016-11-01
Questions regarding the malleability of the mirror neuron system (MNS) continue to be debated. MNS activation has been reported when people observe another person performing biological goal-directed behaviors, such as grasping a cup. These findings support the importance of mapping goal-directed biological behavior onto one's motor repertoire as a means of understanding the actions of others. Still, other evidence supports the Associative Sequence Learning (ASL) model which predicts that the MNS responds to a variety of stimuli after sensorimotor learning, not simply biological behavior. MNS activity develops as a consequence of developing stimulus-response associations between a stimulus and its motor outcome. Findings from the ideomotor literature indicate that stimuli that are more ideomotor compatible with a response are accompanied by an increase in response activation compared to less compatible stimuli; however, non-compatible stimuli robustly activate a constituent response after sensorimotor learning. Here, we measured changes in the mu-rhythm, an EEG marker thought to index MNS activity, predicting that stimuli that differ along dimensions of ideomotor compatibility should show changes in mirror neuron activation as participants learn the respective stimulus-response associations. We observed robust mu-suppression for ideomotor-compatible hand actions and partially compatible dot animations prior to learning; however, compatible stimuli showed greater mu-suppression than partially or non-compatible stimuli after explicit learning. Additionally, non-compatible abstract stimuli exceeded baseline only after participants explicitly learned the motor responses associated with the stimuli. We conclude that the empirical differences between the biological and ASL accounts of the MNS can be explained by Ideomotor Theory. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kass, Michael D.; West, Brian H.
The compatibility of key fuel system infrastructure plastics with 39 bio-blendstock fuel candidates was examined using Hansen solubility analysis. Fuel types included multiple alcohols, esters, ethers, ketones, alkenes and one alkane. These compounds were evaluated as neat molecules and as blends with the gasoline surrogate, dodecane, and a mix of dodecane and 10% ethanol (E10D). The plastics included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), polybutylene terephthalate (PBT), polypropylene (PP), high density polyethylene (HDPE), along with several nylon grades. These materials have been rigorously studied with other fuel types, and their volume change resultsmore » were found to correspond well with their predicted solubility levels.The compatibility was assessed using Hansen solubility parameters and in many instances peak solubility occurred for blends rather than the neat fuel components. The results showed that good compatibilities can be expected for PPS, PVDF, PET, nylons, acetal, PEI, PVC, HDPE and PBT. PTFE showed potential incompatibilities at low blend concentrations, especially when E10D was used as the base fuel blend. Although, the nylons show good overall compatibility, the results do indicate that mid-range and high alcohol contents may not be suitable for Nylon 6 and Nylon 11 in applications requiring low volume swell. Poor potential compatibility was limited to two plastic types; PETG exposed to mid and high blend levels of the ethers and PP exposed to sabinene and the aromatics. In general, the data showed good compatibility for the majority of the candidate fuels and plastics.« less
Kass, Michael D.; West, Brian H.
2018-01-03
The compatibility of key fuel system infrastructure plastics with 39 bio-blendstock fuel candidates was examined using Hansen solubility analysis. Fuel types included multiple alcohols, esters, ethers, ketones, alkenes and one alkane. These compounds were evaluated as neat molecules and as blends with the gasoline surrogate, dodecane, and a mix of dodecane and 10% ethanol (E10D). The plastics included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), polybutylene terephthalate (PBT), polypropylene (PP), high density polyethylene (HDPE), along with several nylon grades. These materials have been rigorously studied with other fuel types, and their volume change resultsmore » were found to correspond well with their predicted solubility levels.The compatibility was assessed using Hansen solubility parameters and in many instances peak solubility occurred for blends rather than the neat fuel components. The results showed that good compatibilities can be expected for PPS, PVDF, PET, nylons, acetal, PEI, PVC, HDPE and PBT. PTFE showed potential incompatibilities at low blend concentrations, especially when E10D was used as the base fuel blend. Although, the nylons show good overall compatibility, the results do indicate that mid-range and high alcohol contents may not be suitable for Nylon 6 and Nylon 11 in applications requiring low volume swell. Poor potential compatibility was limited to two plastic types; PETG exposed to mid and high blend levels of the ethers and PP exposed to sabinene and the aromatics. In general, the data showed good compatibility for the majority of the candidate fuels and plastics.« less
Apollo-Soyuz test project docking system
NASA Technical Reports Server (NTRS)
Swan, W. L., Jr.
1976-01-01
The United States and Soviet Union in July 1975 successfully completed a joint space mission utilizing each country's spacecraft and the compatible docking system designed and fabricated by each country. The compatible docking system is described, along with the extensive research, development, and testing leading up to the successful mission. It also describes the formulation and implementation of methods for breaking the language barrier, bridging the extensive distances for communication and travel, and adjusting to each country's different culture during the three-year development program.
Flexible DCP interface. [signal conditioning system for use with Kansas environmental sensors
NASA Technical Reports Server (NTRS)
Kanemasu, E. T. (Principal Investigator); Schimmelpfenning, H.
1974-01-01
The author has identified the following significant results. A user of an ERTS data collection system must supply the sensors and signal conditioning interface. The electronic interface must be compatible with the NASA-furnished data collection platform (DCP). A universal signal conditioning system for use with a wide range of environmental sensors is described. The interface is environmentally and electronically compatible with the DCP and has operated satisfactorily for a complete winter wheat growing season in Kansas.
NASA Technical Reports Server (NTRS)
Faget, N. M.
1986-01-01
Attention is given to results obtained to date in developmental investigations of a thermal energy storage (TES) system for the projected NASA Space Station's solar dynamic power system; these tests have concentrated on issues related to materials compatibility for phase change materials (PCMs) and their containment vessels' materials. The five PCMs tested have melting temperatures that correspond to the operating temperatures of either the Brayton or Rankine heat engines, which were independently chosen for their high energy densities.
NASA Astrophysics Data System (ADS)
Tsui, Benjamin M. W.; Hugg, James W.; Xu, Jingyan; Chen, Si; Meier, Dirk; Edelstein, William; El-Sharkawy, Abdel; Wagenaar, Douglas J.; Patt, Bradley E.
2011-03-01
We describe a continuing design and development of MR-compatible SPECT systems for simultaneous SPECT-MR imaging of small animals. A first generation prototype SPECT system was designed and constructed to fit inside a MRI system with a gradient bore inner diameter of 12 cm. It consists of 3 angularly offset rings of 8 detectors (1"x1", 16x16 pixels MR-compatible solid-state CZT). A matching 24-pinhole collimator sleeve, made of a tungsten-compound, provides projections from a common FOV of ~25 mm. A birdcage RF coil for MRI data acquisition surrounds the collimator. The SPECT system was tested inside a clinical 3T MRI system. Minimal interference was observed on the simultaneously acquired SPECT and MR images. We developed a sparse-view image reconstruction method based on accurate modeling of the point response function (PRF) of each of the 24 pinholes to provide artifact-free SPECT images. The stationary SPECT system provides relatively low resolution of 3-5 mm but high geometric efficiency of 0.5- 1.2% for fast dynamic acquisition, demonstrated in a SPECT renal kinetics study using Tc-99m DTPA. Based on these results, a second generation prototype MR-compatible SPECT system with an outer diameter of 20 cm that fits inside a mid-sized preclinical MRI system is being developed. It consists of 5 rings of 19 CZT detectors. The larger ring diameter allows the use of optimized multi-pinhole collimator designs, such as high system resolution up to ~1 mm, high geometric efficiency, or lower system resolution without collimator rotation. The anticipated performance of the new system is supported by simulation data.
Two-dimensional photon-counting detector arrays based on microchannel array plates
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1975-01-01
The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.
High-volume optical vortex multiplexing and de-multiplexing for free-space optical communication.
Wang, Zhongxi; Zhang, N; Yuan, X-C
2011-01-17
We report an approach to the increase of signal channels in free-space optical communication based on composed optical vortices (OVs). In the encoding process, conventional algorithm employed for the generation of collinearly superimposed OVs is combined with a genetic algorithm to achieve high-volume OV multiplexing. At the receiver end, a novel Dammann vortex grating is used to analyze the multihelix beams with a large number of OVs. We experimentally demonstrate a digitized system which is capable of transmitting and receiving 16 OV channels simultaneously. This system is expected to be compatible with a high-speed OV multiplexing technique, with potentials to extremely high-volume information density in OV communication.
Simple method for experimentally testing any form of quantum contextuality
NASA Astrophysics Data System (ADS)
Cabello, Adán
2016-03-01
Contextuality provides a unifying paradigm for nonclassical aspects of quantum probabilities and resources of quantum information. Unfortunately, most forms of quantum contextuality remain experimentally unexplored due to the difficulty of performing sequences of projective measurements on individual quantum systems. Here we show that two-point correlations between binary compatible observables are sufficient to reveal any form of contextuality. This allows us to design simple experiments that are more robust against imperfections and easier to analyze, thus opening the door for observing interesting forms of contextuality, including those requiring quantum systems of high dimensions. In addition, it allows us to connect contextuality to communication complexity scenarios and reformulate a recent result relating contextuality and quantum computation.
Carey, A.E.; Prudic, David E.
1996-01-01
Documentation is provided of model input and sample output used in a previous report for analysis of ground-water flow and simulated pumping scenarios in Paradise Valley, Humboldt County, Nevada.Documentation includes files containing input values and listings of sample output. The files, in American International Standard Code for Information Interchange (ASCII) or binary format, are compressed and put on a 3-1/2-inch diskette. The decompressed files require approximately 8.4 megabytes of disk space on an International Business Machine (IBM)- compatible microcomputer using the MicroSoft Disk Operating System (MS-DOS) operating system version 5.0 or greater.
An interactive editor for definition of touch-sensitive zones for a graphic display
NASA Technical Reports Server (NTRS)
Monroe, Burt L., III; Jones, Denise R.
1987-01-01
In the continuing effort to develop more efficient man-machine communications methods, touch displays have shown potential as straightforward input systems. The development of software necessary to handle such systems, however, can become tedious. In order to reduce the need for redundant programming, a touch editor has been developed which allows a programmer to interactively define touch-sensitive areas for a graphic display. The information produced during the editing process is written to a data file, which can be accessed easily when needed by an application program. This paper outlines the structure, logic, and use of the editor, as well as the hardware with which it is presently compatible.
Reflective optical imaging system with balanced distortion
Chapman, Henry N.; Hudyma, Russell M.; Shafer, David R.; Sweeney, Donald W.
1999-01-01
An optical system compatible with short wavelength (extreme ultraviolet) An optical system compatible with short wavelength (extreme ultraviolet) radiation comprising four reflective elements for projecting a mask image onto a substrate. The four optical elements comprise, in order from object to image, convex, concave, convex and concave mirrors. The optical system is particularly suited for step and scan lithography methods. The invention enables the use of larger slit dimensions associated with ring field scanning optics, improves wafer throughput and allows higher semiconductor device density. The inventive optical system is characterized by reduced dynamic distortion because the static distortion is balanced across the slit width.
Delgado-Dávila, R; Martén-Rodríguez, S; Huerta-Ramos, G
2016-11-01
This study tested the hypothesis that self-compatibility would be associated with floral traits that facilitate autonomous self-pollination to ensure reproduction under low pollinator visitation. In a comparison of two pairs of Ipomoea species with contrasting breeding systems, we predicted that self-compatible (SC) species would have smaller, less variable flowers, reduced herkogamy, lower pollinator visitation and higher reproductive success than their self-incompatible (SI) congeners. We studied sympatric species pairs, I. hederacea (SC)- I. mitchellae (SI) and I. purpurea (SC)-I. indica (SI), in Mexico, over two years. We quantified variation in floral traits and nectar production, documented pollinator visitation, and determined natural fruit and seed set. Hand-pollination and bagging experiments were conducted to determine potential for autonomous self-pollination and apomixis. Self-compatible Ipomoea species had smaller flowers and lower nectar production than SI species; however, floral variation and integration did not vary according to breeding system. Bees were primary pollinators of all species, but visitation rates were seven times lower in SC than SI species. SC species had a high capacity for autonomous self-pollination due to reduced herkogamy at the highest anther levels. Self-compatible species had two to six times higher fruit set than SI species. Results generally support the hypothesis that self-compatibility and autonomous self-pollination ensure reproduction under low pollinator visitation. However, high variation in morphological traits of SC Ipomoea species suggests they maintain variation through outcrossing. Furthermore, reduced herkogamy was associated with high potential for autonomous self-pollination, providing a reproductive advantage that possibly underlies transitions to self-compatibility in Ipomoea. © 2016 German Botanical Society and The Royal Botanical Society of the Netherlands.
NASA Technical Reports Server (NTRS)
1978-01-01
The progress made on the development and delivery of noncorrosive fluid subsystems is reported. These subsystems are to be compatible with closed-loop solar heating or combined heating and hot water systems. They are also to be compatible with both metallic and non-metallic plumbing systems. At least 100 gallons of each type of fluid recommended by the contractor will be delivered under the contract. The performance testing of a number of fluids is described.
SDIA: A dynamic situation driven information fusion algorithm for cloud environment
NASA Astrophysics Data System (ADS)
Guo, Shuhang; Wang, Tong; Wang, Jian
2017-09-01
Information fusion is an important issue in information integration domain. In order to form an extensive information fusion technology under the complex and diverse situations, a new information fusion algorithm is proposed. Firstly, a fuzzy evaluation model of tag utility was proposed that can be used to count the tag entropy. Secondly, a ubiquitous situation tag tree model is proposed to define multidimensional structure of information situation. Thirdly, the similarity matching between the situation models is classified into three types: the tree inclusion, the tree embedding, and the tree compatibility. Next, in order to reduce the time complexity of the tree compatible matching algorithm, a fast and ordered tree matching algorithm is proposed based on the node entropy, which is used to support the information fusion by ubiquitous situation. Since the algorithm revolve from the graph theory of disordered tree matching algorithm, it can improve the information fusion present recall rate and precision rate in the situation. The information fusion algorithm is compared with the star and the random tree matching algorithm, and the difference between the three algorithms is analyzed in the view of isomorphism, which proves the innovation and applicability of the algorithm.
Robonaut's Flexible Information Technology Infrastructure
NASA Technical Reports Server (NTRS)
Askew, Scott; Bluethmann, William; Alder, Ken; Ambrose, Robert
2003-01-01
Robonaut, NASA's humanoid robot, is designed to work as both an astronaut assistant and, in certain situations, an astronaut surrogate. This highly dexterous robot performs complex tasks under telepresence control that could previously only be carried out directly by humans. Currently with 47 degrees of freedom (DOF), Robonaut is a state-of-the-art human size telemanipulator system. while many of Robonaut's embedded components have been custom designed to meet packaging or environmental requirements, the primary computing systems used in Robonaut are currently commercial-off-the-shelf (COTS) products which have some correlation to flight qualified computer systems. This loose coupling of information technology (IT) resources allows Robonaut to exploit cost effective solutions while floating the technology base to take advantage of the rapid pace of IT advances. These IT systems utilize a software development environment, which is both compatible with COTS hardware as well as flight proven computing systems, preserving the majority of software development for a flight system. The ability to use highly integrated and flexible COTS software development tools improves productivity while minimizing redesign for a space flight system. Further, the flexibility of Robonaut's software and communication architecture has allowed it to become a widely used distributed development testbed for integrating new capabilities and furthering experimental research.
Modular Integrated Stackable Layers (MISL) 1.1 Design Specification. Design Guideline Document
NASA Technical Reports Server (NTRS)
Yim, Hester J.
2012-01-01
This document establishes the design guideline of the Modular Instrumentation Data Acquisition (MI-DAQ) system in utilization of several designs available in EV. The MI- DAQ provides the options to the customers depending on their system requirements i.e. a 28V interface power supply, a low power battery operated system, a low power microcontroller, a higher performance microcontroller, a USB interface, a Ethernet interface, a wireless communication, various sensor interfaces, etc. Depending on customer's requirements, the each functional board can be stacked up from a bottom level of power supply to a higher level of stack to provide user interfaces. The stack up of boards are accomplished by a predefined and standardized power bus and data bus connections which are included in this document along with other physical and electrical guidelines. This guideline also provides information for a new design options. This specification is the product of a collaboration between NASA/JSC/EV and Texas A&M University. The goal of the collaboration is to open source the specification and allow outside entities to design, build, and market modules that are compatible with the specification. NASA has designed and is using numerous modules that are compatible to this specification. A limited number of these modules will also be released as open source designs to support the collaboration. The released designs are listed in the Applicable Documents.
Iwano, Megumi; Igarashi, Motoko; Tarutani, Yoshiaki; Kaothien-Nakayama, Pulla; Nakayama, Hideki; Moriyama, Hideki; Yakabe, Ryo; Entani, Tetsuyuki; Shimosato-Asano, Hiroko; Ueki, Masao; Tamiya, Gen; Takayama, Seiji
2014-01-01
In the Brassicaceae, intraspecific non-self pollen (compatible pollen) can germinate and grow into stigmatic papilla cells, while self-pollen or interspecific pollen is rejected at this stage. However, the mechanisms underlying this selective acceptance of compatible pollen remain unclear. Here, using a cell-impermeant calcium indicator, we showed that the compatible pollen coat contains signaling molecules that stimulate Ca2+ export from the papilla cells. Transcriptome analyses of stigmas suggested that autoinhibited Ca2+-ATPase13 (ACA13) was induced after both compatible pollination and compatible pollen coat treatment. A complementation test using a yeast Saccharomyces cerevisiae strain lacking major Ca2+ transport systems suggested that ACA13 indeed functions as an autoinhibited Ca2+ transporter. ACA13 transcription increased in papilla cells and in transmitting tracts after pollination. ACA13 protein localized to the plasma membrane and to vesicles near the Golgi body and accumulated at the pollen tube penetration site after pollination. The stigma of a T-DNA insertion line of ACA13 exhibited reduced Ca2+ export, as well as defects in compatible pollen germination and seed production. These findings suggest that stigmatic ACA13 functions in the export of Ca2+ to the compatible pollen tube, which promotes successful fertilization. PMID:24569769
Atuarfitsialak: Greenland's Cultural Compatible Reform
ERIC Educational Resources Information Center
Wyatt, Tasha R.
2012-01-01
In 2002, Greenlandic reform leaders launched a comprehensive, nation-wide reform to create culturally compatible education. Greenland's reform work spans the entire educational system and includes preschool through higher education. To assist their efforts, reform leaders adopted the Standards for Effective Pedagogy developed at the Center for…
Health data and data governance.
Hovenga, Evelyn J S; Grain, Heather
2013-01-01
Health is a knowledge industry, based on data collected to support care, service planning, financing and knowledge advancement. Increasingly there is a need to collect, retrieve and use health record information in an electronic format to provide greater flexibility, as this enables retrieval and display of data in multiple locations and formats irrespective of where the data were collected. Electronically maintained records require greater structure and consistency to achieve this. The use of data held in records generated in real time in clinical systems also has the potential to reduce the time it takes to gain knowledge, as there is less need to collect research specific information, this is only possible if data governance principles are applied. Connected devices and information systems are now generating huge amounts of data, as never before seen. An ability to analyse and mine very large amounts of data, "Big Data", provides policy and decision makers with new insights into varied aspects of work and information flow and operational business patterns and trends, and drives greater efficiencies, and safer and more effective health care. This enables decision makers to apply rules and guidance that have been developed based upon knowledge from many individual patient records through recognition of triggers based upon that knowledge. In clinical decision support systems information about the individual is compared to rules based upon knowledge gained from accumulated information of many to provide guidance at appropriate times in the clinical process. To achieve this the data in the individual system, and the knowledge rules must be represented in a compatible and consistent manner. This chapter describes data attributes; explains the difference between data and information; outlines the requirements for quality data; shows the relevance of health data standards; and describes how data governance impacts representation of content in systems and the use of that information.
Operational Interoperability Challenges on the Example of GEOSS and WIS
NASA Astrophysics Data System (ADS)
Heene, M.; Buesselberg, T.; Schroeder, D.; Brotzer, A.; Nativi, S.
2015-12-01
The following poster highlights the operational interoperability challenges on the example of Global Earth Observation System of Systems (GEOSS) and World Meteorological Organization Information System (WIS). At the heart of both systems is a catalogue of earth observation data, products and services but with different metadata management concepts. While in WIS a strong governance with an own metadata profile for the hundreds of thousands metadata records exists, GEOSS adopted a more open approach for the ten million records. Furthermore, the development of WIS - as an operational system - follows a roadmap with committed downwards compatibility while the GEOSS development process is more agile. The poster discusses how the interoperability can be reached for the different metadata management concepts and how a proxy concept helps to couple two different systems which follow a different development methodology. Furthermore, the poster highlights the importance of monitoring and backup concepts as a verification method for operational interoperability.
Radio-frequency energy quantification in magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Alon, Leeor
Mapping of radio frequency (RF) energy deposition has been challenging for 50+ years, especially, when scanning patients in the magnetic resonance imaging (MRI) environment. As result, electromagnetic simulation software is often used for estimating the specific absorption rate (SAR), the rate of RF energy deposition in tissue. The thesis work presents challenges associated with aligning information provided by electromagnetic simulation and MRI experiments. As result of the limitations of simulations, experimental methods for the quantification of SAR were established. A system for quantification of the total RF energy deposition was developed for parallel transmit MRI (a system that uses multiple antennas to excite and image the body). The system is capable of monitoring and predicting channel-by-channel RF energy deposition, whole body SAR and capable of tracking potential hardware failures that occur in the transmit chain and may cause the deposition of excessive energy into patients. Similarly, we demonstrated that local RF power deposition can be mapped and predicted for parallel transmit systems based on a series of MRI temperature mapping acquisitions. Resulting from the work, we developed tools for optimal reconstruction temperature maps from MRI acquisitions. The tools developed for temperature mapping paved the way for utilizing MRI as a diagnostic tool for evaluation of RF/microwave emitting device safety. Quantification of the RF energy was demonstrated for both MRI compatible and non-MRI-compatible devices (such as cell phones), while having the advantage of being noninvasive, of providing millimeter resolution and high accuracy.
Chan, Joshua L; Mazilu, Dumitru; Miller, Justin G; Hunt, Timothy; Horvath, Keith A; Li, Ming
2016-10-01
Real-time magnetic resonance imaging (rtMRI) guidance provides significant advantages during transcatheter aortic valve replacement (TAVR) as it provides superior real-time visualization and accurate device delivery tracking. However, performing a TAVR within an MRI scanner remains difficult due to a constrained procedural environment. To address these concerns, a magnetic resonance (MR)-compatible robotic system to assist in TAVR deployments was developed. This study evaluates the technical design and interface considerations of an MR-compatible robotic-assisted TAVR system with the purpose of demonstrating that such a system can be developed and executed safely and precisely in a preclinical model. An MR-compatible robotic surgical assistant system was built for TAVR deployment. This system integrates a 5-degrees of freedom (DoF) robotic arm with a 3-DoF robotic valve delivery module. A user interface system was designed for procedural planning and real-time intraoperative manipulation of the robot. The robotic device was constructed of plastic materials, pneumatic actuators, and fiber-optical encoders. The mechanical profile and MR compatibility of the robotic system were evaluated. The system-level error based on a phantom model was 1.14 ± 0.33 mm. A self-expanding prosthesis was successfully deployed in eight Yorkshire swine under rtMRI guidance. Post-deployment imaging and necropsy confirmed placement of the stent within 3 mm of the aortic valve annulus. These phantom and in vivo studies demonstrate the feasibility and advantages of robotic-assisted TAVR under rtMRI guidance. This robotic system increases the precision of valve deployments, diminishes environmental constraints, and improves the overall success of TAVR.
StreptomycesInforSys: A web-enabled information repository
Jain, Chakresh Kumar; Gupta, Vidhi; Gupta, Ashvarya; Gupta, Sanjay; Wadhwa, Gulshan; Sharma, Sanjeev Kumar; Sarethy, Indira P
2012-01-01
Members of Streptomyces produce 70% of natural bioactive products. There is considerable amount of information available based on polyphasic approach for classification of Streptomyces. However, this information based on phenotypic, genotypic and bioactive component production profiles is crucial for pharmacological screening programmes. This is scattered across various journals, books and other resources, many of which are not freely accessible. The designed database incorporates polyphasic typing information using combinations of search options to aid in efficient screening of new isolates. This will help in the preliminary categorization of appropriate groups. It is a free relational database compatible with existing operating systems. A cross platform technology with XAMPP Web server has been used to develop, manage, and facilitate the user query effectively with database support. Employment of PHP, a platform-independent scripting language, embedded in HTML and the database management software MySQL will facilitate dynamic information storage and retrieval. The user-friendly, open and flexible freeware (PHP, MySQL and Apache) is foreseen to reduce running and maintenance cost. Availability www.sis.biowaves.org PMID:23275736
ERISTAR: Earth Resources Information Storage, Transformation, Analysis, and Retrieval
NASA Technical Reports Server (NTRS)
1972-01-01
The National Aeronautics and Space Administration (NASA) and the American Society for Engineering Education (ASEE) have sponsored faculty fellowship programs in systems engineering design for the past several years. During the summer of 1972 four such programs were conducted by NASA, with Auburn University cooperating with Marshall Space Flight Center (MSFC). The subject for the Auburn-MSFC design group was ERISTAR, an acronym for Earth Resources Information Storage, Transformation, Analysis and Retrieval, which represents an earth resources information management network of state information centers administered by the respective states and linked to federally administered regional centers and a national center. The considerations for serving the users and the considerations that must be given to processing data from a variety of sources are described. The combination of these elements into a national network is discussed and an implementation plan is proposed for a prototype state information center. The compatibility of the proposed plan with the Department of Interior plan, RALI, is indicated.
StreptomycesInforSys: A web-enabled information repository.
Jain, Chakresh Kumar; Gupta, Vidhi; Gupta, Ashvarya; Gupta, Sanjay; Wadhwa, Gulshan; Sharma, Sanjeev Kumar; Sarethy, Indira P
2012-01-01
Members of Streptomyces produce 70% of natural bioactive products. There is considerable amount of information available based on polyphasic approach for classification of Streptomyces. However, this information based on phenotypic, genotypic and bioactive component production profiles is crucial for pharmacological screening programmes. This is scattered across various journals, books and other resources, many of which are not freely accessible. The designed database incorporates polyphasic typing information using combinations of search options to aid in efficient screening of new isolates. This will help in the preliminary categorization of appropriate groups. It is a free relational database compatible with existing operating systems. A cross platform technology with XAMPP Web server has been used to develop, manage, and facilitate the user query effectively with database support. Employment of PHP, a platform-independent scripting language, embedded in HTML and the database management software MySQL will facilitate dynamic information storage and retrieval. The user-friendly, open and flexible freeware (PHP, MySQL and Apache) is foreseen to reduce running and maintenance cost. www.sis.biowaves.org.
Tsekos, Nikolaos V; Khanicheh, Azadeh; Christoforou, Eftychios; Mavroidis, Constantinos
2007-01-01
The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.
Interrupted object-based updating of reach program leads to a negative compatibility effect.
Vainio, Lari
2009-07-01
The author investigated how the motor program elicited by an object's orientation is updated by object-based information while a participant reaches for the object. Participants selected the hand of response according to the thickness of the graspable object and then reached toward the location in which the object appeared. Reach initiation times decreased when the handle of the object was oriented toward the responding hand. This positive compatibility effect turned into a negative compatibility effect (NCE) during reach execution when the object was removed from the display 300 ms after object onset or replaced with a mask at movement onset. The results demonstrate that interrupted object-based updating of an ongoing reach movement triggers the NCE.
Levine, S; Dyjack, D T
1997-04-01
An International Organization for Standardization (ISO) 9001: 1994-harmonized occupational health and safety (OHS) management system has been written at the University of Michigan, and reviewed, revised, and accepted under the direction of the American Industrial Hygiene Association (AIHA) Occupational Health and Safety Management Systems (OHSMS) Task Force and the Board of Directors. This system is easily adaptable to the ISO 14001 format and to both OHS and environmental management system applications. As was the case with ISO 9001: 1994, this system is expected to be compatible with current production quality and OHS quality systems and standards, have forward compatibility for new applications, and forward flexibility, with new features added as needed. Since ISO 9001: 1987 and 9001: 1994 have been applied worldwide, the incorporation of harmonized OHS and environmental management system components should be acceptable to business units already performing first-party (self-) auditing, and second-party (contract qualification) auditing. This article explains the basis of this OHS management system, its relationship to ISO 9001 and 14001 standards, the philosophy and methodology of an ISO-harmonized system audit, the relationship of these systems to traditional OHS audit systems, and the authors' vision of the future for application of such systems.
Automation technology using Geographic Information System (GIS)
NASA Technical Reports Server (NTRS)
Brooks, Cynthia L.
1994-01-01
Airport Surface Movement Area is but one of the actions taken to increase the capacity and safety of existing airport facilities. The System Integration Branch (SIB) has designed an integrated system consisting of an electronic moving display in the cockpit, and includes display of taxi routes which will warn controllers and pilots of the position of other traffic and warning information automatically. Although, this system has in test simulation proven to be accurate and helpful; the initial process of obtaining an airport layout of the taxi-routes and designing each of them is a very tedious and time-consuming process. Other methods of preparing the display maps are being researched. One such method is the use of the Geographical Information System (GIS). GIS is an integrated system of computer hardware and software linking topographical, demographic and other resource data that is being referenced. The software can support many areas of work with virtually unlimited information compatibility due to the system's open architecture. GIS will allow us to work faster with increased efficiency and accuracy while providing decision making capabilities. GIS is currently being used at the Langley Research Center with other applications and has been validated as an accurate system for that task. GIS usage for our task will involve digitizing aerial photographs of the topology for each taxi-runway and identifying each position according to its specific spatial coordinates. The information currently being used can be integrated with the GIS system, due to its ability to provide a wide variety of user interfaces. Much more research and data analysis will be needed before this technique will be used, however we are hopeful this will lead to better usage of man-power and technological capabilities for the future.
Genetic compatibility, mate choice and patterns of parentage: invited review.
Tregenza, T; Wedell, N
2000-08-01
There is growing interest in the possibility that genetic compatibility may drive mate choice, including gamete choice, particularly from the perspective of understanding why females frequently mate with more than one male. Mate choice for compatibility differs from other forms of choice for genetic benefits (such as 'good genes') because individuals are expected to differ in their mate preferences, changing the evolutionary dynamics of sexual selection. Recent experiments designed to investigate genetic benefits of polyandry suggest that mate choice on the basis of genetic compatibility may be widespread. However, in most systems the mechanisms responsible for variation in compatibility are unknown. We review potential sources of variation in genetic compatibility and whether there is any evidence for mate choice driven by these factors. Selfish genetic elements appear to have the potential to drive mate compatibility mate choice, though as yet there is only one convincing example. There is abundant evidence for assortative mating between populations in hybrid zones, but very few examples where this is clearly a result of selection against mating with genetically less compatible individuals. There are also numerous cases of inbreeding avoidance, but little evidence that mate choice or differential fertilization success driven by genetic compatibility occurs between unrelated individuals. The exceptions to this are a handful of situations where both the alleles causing incompatibility and the alleles involved in mate choice are located in a chromosome region where recombination is suppressed. As yet there are only a few potential sources of genetic compatibility which have clearly been shown to drive mate choice. This may reflect limitations in the potential for the evolution of mate choice for genetic compatibility within populations, although the most promising sources of such incompatibilities have received relatively little research.
Desk-top publishing using IBM-compatible computers.
Grencis, P W
1991-01-01
This paper sets out to describe one Medical Illustration Departments' experience of the introduction of computers for desk-top publishing. In this particular case, after careful consideration of all the options open, an IBM-compatible system was installed rather than the often popular choice of an Apple Macintosh.
Concepts for on-board satellite image registration, volume 1
NASA Technical Reports Server (NTRS)
Ruedger, W. H.; Daluge, D. R.; Aanstoos, J. V.
1980-01-01
The NASA-NEEDS program goals present a requirement for on-board signal processing to achieve user-compatible, information-adaptive data acquisition. One very specific area of interest is the preprocessing required to register imaging sensor data which have been distorted by anomalies in subsatellite-point position and/or attitude control. The concepts and considerations involved in using state-of-the-art positioning systems such as the Global Positioning System (GPS) in concert with state-of-the-art attitude stabilization and/or determination systems to provide the required registration accuracy are discussed with emphasis on assessing the accuracy to which a given image picture element can be located and identified, determining those algorithms required to augment the registration procedure and evaluating the technology impact on performing these procedures on-board the satellite.
Goldstone Solar System Radar (GSSR)
NASA Technical Reports Server (NTRS)
Renzetti, N. A.
1991-01-01
The primary objective of the Goldstone Solar System Radar is the investigation of solar system bodies by means of Earth-based radar. Targets of primary interest include the Galilean moons, Saturn's rings and moons, and Earth-approaching asteroids and comets. Planets are also of interest, particularly Mercury and the planets to which NASA has not yet planned spacecraft visits. Based on a history of solid achievement, including the definition of the Astronomical Unit, imaging and topography of Mars, Venus, and Mercury, and contributions to the general theory of relativity, the program will continue to support flight project requirements and its primary objectives. The individual target objectives are presented, and information on the following topics are presented in tabular form: Deep Space Network support, compatibility tests, telemetry, command, and tracking support responsibility.
Hyam, Roger; Hagedorn, Gregor; Chagnoux, Simon; Röpert, Dominik; Casino, Ana; Droege, Gabi; Glöckler, Falko; Gödderz, Karsten; Groom, Quentin; Hoffmann, Jana; Holleman, Ayco; Kempa, Matúš; Koivula, Hanna; Marhold, Karol; Nicolson, Nicky; Smith, Vincent S.; Triebel, Dagmar
2017-01-01
With biodiversity research activities being increasingly shifted to the web, the need for a system of persistent and stable identifiers for physical collection objects becomes increasingly pressing. The Consortium of European Taxonomic Facilities agreed on a common system of HTTP-URI-based stable identifiers which is now rolled out to its member organizations. The system follows Linked Open Data principles and implements redirection mechanisms to human-readable and machine-readable representations of specimens facilitating seamless integration into the growing semantic web. The implementation of stable identifiers across collection organizations is supported with open source provider software scripts, best practices documentations and recommendations for RDF metadata elements facilitating harmonized access to collection information in web portals. Database URL: http://cetaf.org/cetaf-stable-identifiers PMID:28365724
Study on development and application of platform with students' safety based on SOA
NASA Astrophysics Data System (ADS)
Jiang, Derong
2011-10-01
Students' safety management is a very important work, which is responsible for the entire school student security problems, student safety primarily prevent, only advance predict various of the imminent problems, to better protect their safety. The system mainly used on the development request the student safety management, safety evaluation, safety education, and etc, which are for daily management work completed for students in the security digital management. Development of the system can reduce the safety management for department working pressure, meanwhile, can reduce the labor force to use, accelerate query speed, strengthens the management, as well as the national various departments about the information step, making each management standardized. Therefore, developing a set of suitability and the populace, compatibly good system is very necessary.
NASA Technical Reports Server (NTRS)
Newcomb, J. S.
1975-01-01
The present paper describes an automated system for measuring stellar proper motions on the basis of information contained in photographic plates. In this system, the images on a star plate are digitized by a scanning microdensitometer using light from a He-Ne gas laser, and a special-purpose computer arranges the measurements in computer-compatible form on magnetic tape. The scanning and image-reconstruction processes are briefly outlined, and the image-evaluation techniques are discussed. It is shown that the present system has been especially successful in measuring the proper motions of low-luminosity stars, including 119 stars with less than 1/10,000 of the solar bolometric luminosity. Plans for measurements of high-density Milky Way star plates are noted.
Chemical compatibility issues associated with use of SiC/SiC in advanced reactor concepts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, Dane F.
2015-09-01
Silicon carbide/silicon carbide (SiC/SiC) composites are of interest for components that will experience high radiation fields in the High Temperature Gas Cooled Reactor (HTGR), the Very High Temperature Reactor (VHTR), the Sodium Fast Reactor (SFR), or the Fluoride-cooled High-temperature Reactor (FHR). In all of the reactor systems considered, reactions of SiC/SiC composites with the constituents of the coolant determine suitability of materials of construction. The material of interest is nuclear grade SiC/SiC composites, which consist of a SiC matrix [high-purity, chemical vapor deposition (CVD) SiC or liquid phase-sintered SiC that is crystalline beta-phase SiC containing small amounts of alumina-yttria impurity],more » a pyrolytic carbon interphase, and somewhat impure yet crystalline beta-phase SiC fibers. The interphase and fiber components may or may not be exposed, at least initially, to the reactor coolant. The chemical compatibility of SiC/SiC composites in the three reactor environments is highly dependent on thermodynamic stability with the pure coolant, and on reactions with impurities present in the environment including any ingress of oxygen and moisture. In general, there is a dearth of information on the performance of SiC in these environments. While there is little to no excess Si present in the new SiC/SiC composites, the reaction of Si with O 2 cannot be ignored, especially for the FHR, in which environment the product, SiO 2, can be readily removed by the fluoride salt. In all systems, reaction of the carbon interphase layer with oxygen is possible especially under abnormal conditions such as loss of coolant (resulting in increased temperature), and air and/ or steam ingress. A global outline of an approach to resolving SiC/SiC chemical compatibility concerns with the environments of the three reactors is presented along with ideas to quickly determine the baseline compatibility performance of SiC/SiC.« less
Barnes, Carole; Sutherland, Sandra; Brattesani, Madeline; Wilhoit, Larry; Messenger, Belinda
2012-04-01
The U.S. Environmental Protection Agency encourages school officials to adopt integrated pest management (IPM) to reduce children's exposure to potentially harmful pesticides. In California, the Healthy Schools Act of 2000 (HSA) establishes right-to-know requirements for pesticide use in public schools; requires school districts to designate an IPM coordinator; and requires the California Department of Pesticide Regulation (DPR) to collect pesticide-use information from pest control businesses, conduct IPM training workshops, and promote least-toxic pest management practices. DPR periodically surveys school districts statewide to measure compliance with the HSA and the use of least-toxic management practices compatible with IPM and to guide DPR's training and outreach efforts. Results from three surveys, conducted in 2001, 2002, and 2004, show that an increasing number of districts use ant management practices compatible with IPM; however, fewer districts use IPM-compatible weed management practices. DPR's California School IPM program plans to develop technical materials and to conduct training workshops that will provide districts with more information about how to use an IPM program to prevent and manage weeds.
NASA Astrophysics Data System (ADS)
Barlow, Steven J.
1986-09-01
The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.
Lanaud, Claire; Fouet, Olivier; Legavre, Thierry; Lopes, Uilson; Sounigo, Olivier; Eyango, Marie Claire; Mermaz, Benoit; Da Silva, Marcos Ramos; Loor Solorzano, Rey Gaston; Argout, Xavier; Gyapay, Gabor; Ebaiarrey, Herman Ebai; Colonges, Kelly; Sanier, Christine; Rivallan, Ronan; Mastin, Géraldine; Cryer, Nicholas; Boccara, Michel; Verdeil, Jean-Luc; Efombagn Mousseni, Ives Bruno; Peres Gramacho, Karina; Clément, Didier
2017-10-13
Cocoa self-compatibility is an important yield factor and has been described as being controlled by a late gameto-sporophytic system expressed only at the level of the embryo sac. It results in gametic non-fusion and involves several loci. In this work, we identified two loci, located on chromosomes 1 and 4 (CH1 and CH4), involved in cocoa self-incompatibility by two different processes. Both loci are responsible for gametic selection, but only one (the CH4 locus) is involved in the main fruit drop. The CH1 locus acts prior to the gamete fusion step and independently of the CH4 locus. Using fine-mapping and genome-wide association studies, we focused analyses on restricted regions and identified candidate genes. Some of them showed a differential expression between incompatible and compatible reactions. Immunolocalization experiments provided evidence of CH1 candidate genes expressed in ovule and style tissues. Highly polymorphic simple sequence repeat (SSR) diagnostic markers were designed in the CH4 region that had been identified by fine-mapping. They are characterized by a strong linkage disequilibrium with incompatibility alleles, thus allowing the development of efficient diagnostic markers predicting self-compatibility and fruit setting according to the presence of specific alleles or genotypes. SSR alleles specific to self-compatible Amelonado and Criollo varieties were also identified, thus allowing screening for self-compatible plants in cocoa populations. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.
1989-01-01
The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.
Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura
2014-01-01
Abstract. We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures. PMID:24898604
Yim, Eugene S; Choi, Ricky Y; VanRooyen, Michael
2009-01-01
Humanitarian agencies in North Korea operate within a complex sociopolitical environment historically characterized by a baseline of mistrust. As a result of operating within such a heated environment, health sector collaborations between such agencies and the North Korean government have followed unpredictable courses. The factors that have contributed to successful programmatic collaborations, as perceived by United States non-governmental organizations (NGOs) and North Korean officials were investigated. A qualitative, multi-case, comparative, research design using semistructured interviews was used. Expert North Korean informants were interviewed to generate a list of factors contributing to programmatic success, defined as fulfilling mutually established objectives through collaboration. The North Korean informants were asked to identify US NGOs that fulfill these criteria ("mission-compatible NGOs"). Representatives from all of the mission compatible NGOs were interviewed. All informants provided their perspectives on the factors that contributed to successful programmatic collaborations. The interviews were recorded, transcribed, and analyzed for thematic content. North Korean informants identified six mission-compatible US NGOs. The North Korean and US NGO informants provided a number of factors that contributed to successful programs. These factors were grouped into the following themes: (1) responsiveness to North Korean requests; (2) resident status; (3) program monitoring; (4) sincerity (apolitical objectives); (5) information gathering; and (6) interagency collaboration. Some US NGOs have devised innovative measures to work within a unique set of parameters in North Korea. Both US NGOs and North Korean authorities have made significant concessions to maintain their programmatic partnerships. In this manner, seasoned collaborators have employed creative strategies and a form of health diplomacy to facilitate programmatic success in North Korea by building trust within a complex sociopolitical space.
Material Compatibility with Space Storable Propellants. Design Guidebook
NASA Technical Reports Server (NTRS)
Uney, P. E.; Fester, D. A.
1972-01-01
An important consideration in the design of spacecraft for interplanetary missions is the compatibility of storage materials with the propellants. Serious problems can arise because many propellants are either extremely reactive or subject to catalytic decomposition, making the selection of proper materials of construction for propellant containment and control a critical requirement for the long-life applications. To aid in selecting materials and designing and evaluating various propulsion subsystems, available information on the compatibility of spacecraft materials with propellants of interest was compiled from literature searches and personal contacts. The compatibility of both metals and nonmetals with hydrazine, monomethyl hydrazine, nitrated hydrazine, and diborance fuels and nitrogen tetroxide, fluorine, oxygen difluoride, and Flox oxidizers was surveyed. These fuels and oxidizers encompass the wide variety of problems encountered in propellant storage. As such, they present worst case situations of the propellant affecting the material and the material affecting the propellant. This includes material attack, propellant decomposition, and the formation of clogging materials.
CO2 controlled flocculation of microalgae using pH responsive cellulose nanocrystals
NASA Astrophysics Data System (ADS)
Eyley, Samuel; Vandamme, Dries; Lama, Sanjaya; van den Mooter, Guy; Muylaert, Koenraad; Thielemans, Wim
2015-08-01
Cellulose nanocrystals were grafted with imidazole functionalities up to DS 0.06 using a one-pot functionalization strategy. The resulting nanocrystals were shown to have a pH responsive surface charge which was found to be positive below pH 6 and negative above pH 7. These imidazolyl cellulose nanocrystals were tested for flocculation of Chlorella vulgaris using CO2 to induce flocculation. Up to 90% flocculation efficiency was achieved with 200 mg L-1 dose. Furthermore, the modified cellulose nanocrystals showed good compatibility with the microalgae during cultivation, giving potential for the production of reversible flocculation systems.Cellulose nanocrystals were grafted with imidazole functionalities up to DS 0.06 using a one-pot functionalization strategy. The resulting nanocrystals were shown to have a pH responsive surface charge which was found to be positive below pH 6 and negative above pH 7. These imidazolyl cellulose nanocrystals were tested for flocculation of Chlorella vulgaris using CO2 to induce flocculation. Up to 90% flocculation efficiency was achieved with 200 mg L-1 dose. Furthermore, the modified cellulose nanocrystals showed good compatibility with the microalgae during cultivation, giving potential for the production of reversible flocculation systems. Electronic supplementary information (ESI) available: Spectra for all products. See DOI: 10.1039/C5NR03853G
Sonenshein, R.S.
1996-01-01
A technique has been developed to determine a wetlands hydroperiod by comparing simulated water levels from a ground-water flow model and land- surface elevation data through a geographic information system. The simulated water levels are compared with the land-surface elevation data to determine the height of the water surface above or below land surface for the area of interest. Finally, the hydroperiod is determined for established time periods using criteria specified by the user. The program application requires the use of geographic information system software (ARC/INFO), including the TIN and GRID subsystems of the software. The application consists of an ANSI compatible C program to translate ground- water data output from the U.S. Geological Survey modular three-dimensional, finite-difference, ground-water flow model (MODFLOW) into a format that can be used as input for the geographic information system programs (AML's). The application uses ARC/INFO AML programs and ARC/INFO menu interface programs to create digital spatial data layers of the land surface and water surface and to determine the hydroperiod. The technique can be used to evaluate and manage wetlands hydrology.
NASA Technical Reports Server (NTRS)
2007-01-01
This document provides definition of technology human interface requirements for Collision Avoidance (CA). This was performed through a review of CA-related, HSI requirements documents, standards, and recommended practices. Technology concepts in use by the Access 5 CA work package were considered... Beginning with the HSI high-level functional requirement for CA, and CA technology elements, HSI requirements for the interface to the pilot were identified. Results of the analysis describe (1) the information required by the pilot to have knowledge CA system status, and (2) the control capability needed by the pilot to obtain CA information and affect an avoidance maneuver. Fundamentally, these requirements provide the candidate CA technology concepts with the necessary human-related elements to make them compatible with human capabilities and limitations. The results of the analysis describe how CA operations and functions should interface with the pilot to provide the necessary CA functionality to the UA-pilot system .Requirements and guidelines for CA are partitioned into four categories: (1) General, (2) Alerting, (3) Guidance, and (4) Cockpit Display of Traffic Information. Each requirement is stated and is supported with a rationale and associated reference(s).
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
Xu, Y H; Dragan, Y P; Campbell, H A; Pitot, H C
1998-04-01
The most common organ site of neoplasms induced by carcinogenic chemicals in the rodent bioassay is the liver. The development of cancer in rodent liver is a multistage process involving sequentially the stages of initiation, promotion, and progression. During the stages of promotion and progression, numerous lesions termed altered hepatic foci (AHF) develop. STEREO was developed for the purpose of efficient and accurate quantitation of AHF and related lesions in experimental and test rodents. The system utilized is equipped with a microcomputer (IBM-compatible PC running Windows 95) and a Summagraphics MICROGRID or SummaSketch tablet digitizer. The program records information from digitization of single or serial sections obtained randomly from rat liver tissue. With this information and the methods of quantitative stereology, both the number and volume percentage fraction of AHF in liver are calculated in three dimensions. The recorded data files can be printed graphically or in the format of tabular numerical data. The results of stereologic calculations are stored on floppy disks and can be sorted into different categories and analyzed or displayed with the use of statistics and graphic functions built into the overall program. Results may also be exported into Microsoft Excel for use at a later time. Any IBM-compatible PC capable of utilizing Windows 95 and MS Office can be used with STEREO, which offers inexpensive, easily operated software to obtain three-dimensional information from sections of two dimensions for the identification and relative potency of initiators, promoters, and progressors, and for the establishment of information potentially useful in developing estimations of risk for human cancer.
Time Course Analyses Confirm Independence of Imitative and Spatial Compatibility
ERIC Educational Resources Information Center
Catmur, Caroline; Heyes, Cecilia
2011-01-01
Imitative compatibility, or automatic imitation, has been used as a measure of imitative performance and as a behavioral index of the functioning of the human mirror system (e.g., Brass, Bekkering, Wohlschlager, & Prinz, 2000; Heyes, Bird, Johnson, & Haggard, 2005; Kilner, Paulignan, & Blakemore, 2003). However, the use of imitative…
Bao, H L; Fang, L W; Wang, L H
2017-01-06
Cervical cancer is one of the most common malignancies among women. Screening programs for cervical cancer have been implemented in many developed countries. Comprehensive systems for cervical cancer prevention and control have improved over the past 30 years, which has led to a significant decline in the morbidity and mortality of cervical cancer. Since 2009, the Chinese government has conducted the Cervical Cancer and Breast Cancer Screening Program for Rural Women on a national scale, which has substantially improved cervical cancer prevention and control. However, a comprehensive system for cervical cancer prevention has been not established in China. It is essential to investigate suitable strategies for cervical cancer prevention system in the country by referring to the experiences of developed nations in comparison with the situation in China, with respect to system operations, compatibility with the existing health care system, choice of suitable technologies, and information and evaluation platforms.
Object-oriented analysis and design of a health care management information system.
Krol, M; Reich, D L
1999-04-01
We have created a prototype for a universal object-oriented model of a health care system compatible with the object-oriented approach used in version 3.0 of the HL7 standard for communication messages. A set of three models has been developed: (1) the Object Model describes the hierarchical structure of objects in a system--their identity, relationships, attributes, and operations; (2) the Dynamic Model represents the sequence of operations in time as a collection of state diagrams for object classes in the system; and (3) functional Diagram represents the transformation of data within a system by means of data flow diagrams. Within these models, we have defined major object classes of health care participants and their subclasses, associations, attributes and operators, states, and behavioral scenarios. We have also defined the major processes and subprocesses. The top-down design approach allows use, reuse, and cloning of standard components.
A survey of compatibility of materials with high pressure oxygen service
NASA Technical Reports Server (NTRS)
Hust, J. G.; Clark, A. F.
1972-01-01
The available information on the compatibility of materials with oxygen as applied to the production, transport, and applications experience of high pressure liquid and gaseous oxygen is compiled. High pressure is defined as about 2000 to 3000 psia. Since high pressure projections sometimes can be made from lower pressure data, some low pressure data are also included. Low pressure data are included if they are considered helpful to a better understanding of the behavior at high pressures.
NASA Technical Reports Server (NTRS)
Harper, Susan A.; Juarez, Alfredo; Peralta, Stephen F.; Stoltzfus, Joel; Arpin, Christina Pina; Beeson, Harold D.
2016-01-01
Solvents used to clean oxygen system components must be assessed for oxygen compatibility, as incompatible residue or fluid inadvertently left behind within an oxygen system can pose a flammability risk. The most recent approach focused on solvent ignition susceptibility to assess the flammability risk associated with these materials. Previous evaluations included Ambient Pressure Liquid Oxygen (LOX) Mechanical Impact Testing (ASTM G86) and Autogenous Ignition Temperature (AIT) Testing (ASTM G72). The goal in this approach was to identify a solvent material that was not flammable in oxygen. As environmental policies restrict the available options of acceptable solvents, it has proven difficult to identify one that is not flammable in oxygen. A more rigorous oxygen compatibility approach is needed in an effort to select a new solvent for NASA applications. NASA White Sands Test Facility proposed an approach that acknowledges oxygen flammability, yet selects solvent materials based on their relative oxygen compatibility ranking, similar to that described in ASTM G63-99. Solvents are selected based on their ranking with respect to minimal ignition susceptibility, damage and propagation potential, as well as their relative ranking when compared with other solvent materials that are successfully used in oxygen systems. Test methods used in this approach included ASTM G86 (Ambient Pressure LOX Mechanical Impact Testing and Pressurized Gaseous Oxygen (GOX) Mechanical Impact Testing), ASTM G72 (AIT Testing), and ASTM D240 (Heat of Combustion (HOC) Testing). Only four solvents were tested through the full battery of tests for evaluation of oxygen compatibility: AK-225G as a baseline comparison, Solstice PF, L-14780, and Vertrel MCA. Baseline solvent AK-225G exhibited the lowest HOC and highest AIT of solvents tested. Nonetheless, Solstice PF, L-14780, and Vertrel MCA HOCs all fell well within the range of properties that are associated with proven oxygen system materials. Tested AITs for these solvents fell only slightly lower than the AIT for the proven AK-225G solvent. Based on these comparisons in which solvents exhibited properties within those ranges seen with proven oxygen system materials, it is believed that Solstice PF, L-14780, and Vertrel MCA would perform well with respect to oxygen compatibility.
Rapp, Bastian E; Schickling, Benjamin; Prokop, Jürgen; Piotter, Volker; Rapp, Michael; Länge, Kerstin
2011-10-01
We describe an integration strategy for arbitrary sensors intended to be used as biosensors in biomedical or bioanalytical applications. For such devices ease of handling (by a potential end user) as well as strict disposable usage are of importance. Firstly we describe a generic array compatible polymer sensor housing with an effective sample volume of 1.55 μl. This housing leaves the sensitive surface of the sensor accessible for the application of biosensing layers even after the embedding. In a second step we show how this sensor housing can be used in combination with a passive disposable microfluidic chip to set up arbitrary 8-fold sensor arrays and how such a system can be complemented with an indirect microfluidic flow injection analysis (FIA) system. This system is designed in a way that it strictly separates between disposable and reusable components- by introducing tetradecane as an intermediate liquid. This results in a sensor system compatible with the demands of most biomedical applications. Comparative measurements between a classical macroscopic FIA system and this integrated indirect microfluidic system are presented. We use a surface acoustic wave (SAW) sensor as an exemplary detector in this work.
NASA Astrophysics Data System (ADS)
Gill, Douglas M.; Rasras, Mahmoud; Tu, Kun-Yii; Chen, Young-Kai; White, Alice E.; Patel, Sanjay S.; Carothers, Daniel; Pomerene, Andrew; Kamocsai, Robert; Beattie, James; Kopa, Anthony; Apsel, Alyssa; Beals, Mark; Mitchel, Jurgen; Liu, Jifeng; Kimerling, Lionel C.
2008-02-01
Integrating electronic and photonic functions onto a single silicon-based chip using techniques compatible with mass-production CMOS electronics will enable new design paradigms for existing system architectures and open new opportunities for electro-optic applications with the potential to dramatically change the management, cost, footprint, weight, and power consumption of today's communication systems. While broadband analog system applications represent a smaller volume market than that for digital data transmission, there are significant deployments of analog electro-optic systems for commercial and military applications. Broadband linear modulation is a critical building block in optical analog signal processing and also could have significant applications in digital communication systems. Recently, broadband electro-optic modulators on a silicon platform have been demonstrated based on the plasma dispersion effect. The use of the plasma dispersion effect within a CMOS compatible waveguide creates new challenges and opportunities for analog signal processing since the index and propagation loss change within the waveguide during modulation. We will review the current status of silicon-based electrooptic modulators and also linearization techniques for optical modulation.
An MRI-compatible hand sensory vibrotactile system.
Wang, Fa; Lakshminarayanan, Kishor; Slota, Gregory P; Seo, Na Jin; Webster, John G
2015-01-01
Recently, the application of vibrotactile noise to the wrist or back of the hand has been shown to enhance fingertip tactile sensory perception (Enders et al 2013), supporting the potential for an assistive device worn at the wrist, that generates minute vibrations to help the elderly or patients with sensory deficit. However, knowledge regarding the detailed physiological mechanism behind this sensory improvement in the central nervous system, especially in the human brain, is limited, hindering progress in development and use of such assistive devices. To enable investigation of the impact of vibrotactile noise on sensorimotor brain activity in humans, a magnetic resonance imaging (MRI)-compatible vibrotactile system was developed to provide vibrotactile noise during an MRI of the brain. The vibrotactile system utilizes a remote (outside the MR room) signal amplifier which provides a voltage from -40 to +40 V to drive a 12 mm diameter piezoelectric vibrator (inside the MR room). It is portable and is found to be MRI-compatible which enables its use for neurologic investigation with MRI. The system was also found to induce an improvement in fingertip tactile sensation, consistent with the previous study.
NASA Technical Reports Server (NTRS)
Perry, Jay L.; Arnold, William a.
2006-01-01
The design and operation of crewed spacecraft requires identifying and evaluating chemical compounds that may present reactivity and compatibility risks with the environmental control and life support (ECLS) system. Such risks must be understood so that appropriate design and operational controls, including specifying containment levels, can be instituted or an appropriate substitute material selected. Operational experience acquired during the International Space Station (ISS) program has found that understanding ECLS system and environmental impact presented by thermal control system working fluids is imperative to safely operating any crewed space exploration vehicle. Perfluorocarbon fluids are used as working fluids in thermal control fluid loops on board the ISS. Also, payload hardware developers have identified perfluorocarbon fluids as preferred thermal control working fluids. Interest in using perfluorocarbon fluids as thermal control system working fluids for future crewed space vehicles and outposts is high. Potential hazards associated with perfluorocarbon fluids are discussed with specific attention given to engineering assessment of ECLS system compatibility, compatibility testing results, and spacecraft environmental impact. Considerations for perfluorocarbon fluid use on crewed spacecraft and outposts are summarized.
Incentive compatibility in kidney exchange problems.
Villa, Silvia; Patrone, Fioravante
2009-12-01
The problem of kidney exchanges shares common features with the classical problem of exchange of indivisible goods studied in the mechanism design literature, while presenting additional constraints on the size of feasible exchanges. The solution of a kidney exchange problem can be summarized in a mapping from the relevant underlying characteristics of the players (patients and their donors) to the set of matchings. The goal is to select only matchings maximizing a chosen welfare function. Since the final outcome heavily depends on the private information in possess of the players, a basic requirement in order to reach efficiency is the truthful revelation of this information. We show that for the kidney exchange problem, a class of (in principle) efficient mechanisms does not enjoy the incentive compatibility property and therefore is subject to possible manipulations made by the players in order to profit of the misrepresentation of their private information.
Breastfeeding information in pharmacology textbooks: a content analysis.
Amir, Lisa H; Raval, Manjri; Hussainy, Safeera Y
2013-07-01
Women often need to take medicines while breastfeeding and pharmacists need to provide accurate information in order to avoid undue caution about the compatibility of medicines and breastfeeding. The objective of this study was to review information provided about breastfeeding in commonly used pharmacology textbooks. We asked 15 Australian universities teaching pharmacy courses to provide a list of recommended pharmacology textbooks in 2011. Ten universities responded, generating a list of 11 textbooks that we analysed for content relating to breastfeeding. Pharmacology textbooks outline the mechanisms of actions of medicines and their use: however, only a small emphasis is placed on the safety/compatibility of medicines for women during breastfeeding. Current pharmacology textbooks recommended by Australian universities have significant gaps in their coverage of medicine use in breastfeeding. Authors of textbooks should address this gap, so academic staff can recommend texts with the best lactation content.
Telidon Videotex presentation level protocol: Augmented picture description instructions
NASA Astrophysics Data System (ADS)
Obrien, C. D.; Brown, H. G.; Smirle, J. C.; Lum, Y. F.; Kukulka, J. Z.; Kwan, A.
1982-02-01
The Telidon Videotex system is a method by which graphic and textual information and transactional services can be accessed from information sources by the general public. In order to transmit information to a Telidon terminal at a minimum bandwidth, and in a manner independent of the type of communications channel, a coding scheme was devised which permits the encoding of a picture into the geometric drawing elements which compose it. These picture description instructions are an alpha geometric coding model and are based on the primitives of POINT, LINE, ARC, RECTANGLE, POLYGON, and INCREMENT. Text is encoded as (ASCII) characters along with a supplementary table of accents and special characters. A mosaic shape table is included for compatibility. A detailed specification of the coding scheme and a description of the principles which make it independent of communications channel and display hardware are provided.
The art and science of weed mapping
Barnett, David T.; Stohlgren, Thomas J.; Jarnevich, Catherine S.; Chong, Geneva W.; Ericson, Jenny A.; Davern, Tracy R.; Simonson, Sara E.
2007-01-01
Land managers need cost-effective and informative tools for non-native plant species management. Many local, state, and federal agencies adopted mapping systems designed to collect comparable data for the early detection and monitoring of non-native species. We compared mapping information to statistically rigorous, plot-based methods to better understand the benefits and compatibility of the two techniques. Mapping non-native species locations provided a species list, associated species distributions, and infested area for subjectively selected survey sites. The value of this information may be compromised by crude estimates of cover and incomplete or biased estimations of species distributions. Incorporating plot-based assessments guided by a stratified-random sample design provided a less biased description of non-native species distributions and increased the comparability of data over time and across regions for the inventory, monitoring, and management of non-native and native plant species.
Reactor/Brayton power systems for nuclear electric spacecraft
NASA Technical Reports Server (NTRS)
Layton, J. P.
1980-01-01
Studies are currently underway to assess the technological feasibility of a nuclear-reactor-powered spacecraft propelled by electric thrusters. This vehicle would be capable of performing detailed exploration of the outer planets of the solar system during the remainder of this century. The purpose of this study was to provide comparative information on a closed cycle gas turbine power conversion system. The results have shown that the performance is very competitive and that a 400 kWe space power system is dimensionally compatible with a single Space Shuttle launch. Performance parameters of system mass and radiator area were determined for systems from 100 to 1000 kWe. A 400 kWe reference system received primary attention. The components of this system were defined and a conceptual layout was developed with encouraging results. The preliminary mass determination for the complete power system was very close to the desired goal of 20 kg/kWe. Use of more advanced technology (higher turbine inlet temperature) will substantially improve system performance characteristics.
A Ubiquitous Sensor Network Platform for Integrating Smart Devices into the Semantic Sensor Web
de Vera, David Díaz Pardo; Izquierdo, Álvaro Sigüenza; Vercher, Jesús Bernat; Gómez, Luis Alfonso Hernández
2014-01-01
Ongoing Sensor Web developments make a growing amount of heterogeneous sensor data available to smart devices. This is generating an increasing demand for homogeneous mechanisms to access, publish and share real-world information. This paper discusses, first, an architectural solution based on Next Generation Networks: a pilot Telco Ubiquitous Sensor Network (USN) Platform that embeds several OGC® Sensor Web services. This platform has already been deployed in large scale projects. Second, the USN-Platform is extended to explore a first approach to Semantic Sensor Web principles and technologies, so that smart devices can access Sensor Web data, allowing them also to share richer (semantically interpreted) information. An experimental scenario is presented: a smart car that consumes and produces real-world information which is integrated into the Semantic Sensor Web through a Telco USN-Platform. Performance tests revealed that observation publishing times with our experimental system were well within limits compatible with the adequate operation of smart safety assistance systems in vehicles. On the other hand, response times for complex queries on large repositories may be inappropriate for rapid reaction needs. PMID:24945678
A ubiquitous sensor network platform for integrating smart devices into the semantic sensor web.
de Vera, David Díaz Pardo; Izquierdo, Alvaro Sigüenza; Vercher, Jesús Bernat; Hernández Gómez, Luis Alfonso
2014-06-18
Ongoing Sensor Web developments make a growing amount of heterogeneous sensor data available to smart devices. This is generating an increasing demand for homogeneous mechanisms to access, publish and share real-world information. This paper discusses, first, an architectural solution based on Next Generation Networks: a pilot Telco Ubiquitous Sensor Network (USN) Platform that embeds several OGC® Sensor Web services. This platform has already been deployed in large scale projects. Second, the USN-Platform is extended to explore a first approach to Semantic Sensor Web principles and technologies, so that smart devices can access Sensor Web data, allowing them also to share richer (semantically interpreted) information. An experimental scenario is presented: a smart car that consumes and produces real-world information which is integrated into the Semantic Sensor Web through a Telco USN-Platform. Performance tests revealed that observation publishing times with our experimental system were well within limits compatible with the adequate operation of smart safety assistance systems in vehicles. On the other hand, response times for complex queries on large repositories may be inappropriate for rapid reaction needs.
Managing North American waterfowl in the face of uncertainty
Robbins, C.S.
1995-01-01
Informed management of waterfowl (or any animal population) requires management goals and objectives, the ability to implement management actions, periodic information about population and goal-related varlables, and knowledge of effects of management actions on population and goal-related variables. In North America, international treaties mandate a primary objective of protecting migratory bird populations, with a secondary objective of providing hunting opportunity in a manner compatible with such protection. Through the years, annual establishment of hunting regulations and acquisition and man-agement of habitat have been the primary management actions taken by federal agencies. Various information-gathering programs were established and, by the 1960s, had developed into arguably the best monitoring system in the world for continentally distributed animal populations. Retrospective analyses using estimates from this monitoring system have been used to investigate effects of management actions on waterfowl population and harvest dynamics, but key relationships arc still characterized by uncertainty. We recommend actively adaptive management as an approach that can meet short-term harvest objectives, while reducing uncertainty and ensuring sustainable populations over the long-term.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Franzese, Oscar; Zhang, Li; Mahmoud, Anas M.
There are many instances in which it is possible to plan ahead for an emergency evacuation (e.g., an explosion at a chemical processing facility). For those cases, if an accident (or an attack) were to happen, then the best evacuation plan for the prevailing network and weather conditions would be deployed. In other cases (e.g., the derailment of a train transporting hazardous materials), there may not be any previously developed plan to be implemented and decisions must be made ad-hoc on how to proceed with an emergency evacuation. In both situations, the availability of real-time traffic information plays a criticalmore » role in the management of the evacuation operations. To improve public safety during a vehicular emergency evacuation it is necessary to detect losses of road capacity (due to incidents, for example) as early as possible. Once these bottlenecks are identified, re-routing strategies must be determined in real-time and deployed in the field to help dissipate the congestion and increase the efficiency of the evacuation. Due to cost constraints, only large urban areas have traffic sensor deployments that permit access to some sort of real-time traffic information; any evacuation taking place in any other areas of the country would have to proceed without real-time traffic information. The latter was the focus of this SERRI/DHS (Southeast Region Research Initiative/Department of Homeland Security) sponsored project. That is, the main objective on the project was to improve the operations during a vehicular emergency evacuation anywhere by using newly developed real-time traffic-information-gathering technologies to assess traffic conditions and therefore to potentially detect incidents on the main evacuation routes. Phase A of the project consisted in the development and testing of a prototype system composed of sensors that are engineered in such a way that they can be rapidly deployed in the field where and when they are needed. Each one of these sensors is also equipped with their own power supply and a GPS (Global Positioning System) device to auto-determine its spatial location on the transportation network under surveillance. The system is capable of assessing traffic parameters by identifying and re-identifying vehicles in the traffic stream as those vehicles pass over the sensors. The system of sensors transmits, through wireless communication, real-time traffic information (travel time and other parameters) to a command and control center via an NTCIP (National Transportation Communication for ITS Protocol) -compatible interface. As an alternative, an existing NTCIP-compatible system accepts the real-time traffic information mentioned and broadcasts the traffic information to emergency managers, the media and the public via the existing channels. A series of tests, both in a controlled environment and on the field, were conducted to study the feasibility of rapidly deploying the system of traffic sensors and to assess its ability to provide real-time traffic information during an emergency evacuation. The results of these tests indicated that the prototype sensors are reliable and accurate for the type of application that is the focus of this project.« less
Compatibility of molten salts with advanced solar dynamic receiver materials
NASA Technical Reports Server (NTRS)
Jaworske, D. A.; Perry, W. D.
1989-01-01
Metal-coated graphite fibers are being considered as a thermal conductivity enhancement filler material for molten salts in solar dynamic thermal energy storage systems. The successful metal coating chosen for this application must exhibit acceptable wettability and must be compatible with the molten salt environment. Contact angle values between molten lithium fluoride and several metal, metal fluoride, and metal oxide substrates have been determined at 892 C using a modification of the Wilhelmy plate technique. Reproducible contact angles with repeated exposure to the molten LiF indicated compatibility.
Nash, A A; Phelan, J; Wildy, P
1981-04-01
An adoptive transfer system was used to investigate the H-2 restriction of delayed-type hypersensitivity (DTH) to herpes simplex virus. A successful DTH transfer was achieved when donor and recipient were compatible at the I-A region, with K and D region compatibility unnecessary. However, the rapid clearance of infectious virus from the inoculation site was found only when the donor and recipients were compatible at H-2K (and presumably D) and I-A regions.
Genaidy, Ash M; Rinder, Maria M; Sequeira, Reynold; A-Rehim, Amal
2010-04-01
A community of highly qualified employees is desirable for the workforce to become a competitive business advantage, improving and sustaining corporate health. Currently, the scientific literature is limited on information comparing the assessment of expert and qualified workers for the employee-work environment interface. Such information would be valuable for industrial managers to obtain and act on the different perspectives of its workers for business improvement and survivability. A primary objective of this study is to explore the perspectives of expert and qualified workers on the quality of the employee-work environment interface in a manufacturing enterprise. This investigation was performed in a production department in a small manufacturing enterprise. Two expert workers participated in the study, with each being in the company for 30 years and having performed all jobs in the production department as well as supervisory and line management responsibilities. A total of 13 qualified workers from day and night shifts were used in the study, with the great majority of workers possessing 10 or more years of on-the-job experience but not acquiring the same specialised knowledge required for operating the technological resources in the department. The work compatibility methodology was used to assess the quality of employee-work environment interface for both expert and qualified workers. Both expert and qualified workers provided similar trends in terms of their compatibility assessment of experienced and acting work domains. In general, the compatibility levels for the day shift were poorer than those obtained for the night shift for acting work domains. The similarities in assessment between the expert and qualified workers were much closer for factors impacting job performance at the task and immediate surrounding levels (i.e. physical and mental task content, physical environment). There were greater differences at the macro level, that is, at the process and enterprise levels, in terms of organisational/social/technological environment. This is particularly noted for the organisational environment. The compatibility values obtained for the experienced domains mirror those obtained for acting domains. The overall workload was assessed as requiring major redesign during the day shift and needing added responsibilities for the night shift according to both expert and qualified workers. The assessment of qualified workers is comparable with that of expert workers for the job content and immediate surroundings. Differences are more observed for process- and enterprise-based factors; thereby, providing company management different perspectives in order to devise organisational strategies conducive for optimum human and corporate health and pointing to the probable interactions of the different systems impacting individual and enterprise performance. STATEMENT OF RELEVANCE: This research examines similarities and differences between qualified and expert workers in their assessment of the worker-work environment interface. The contribution to improved understanding of the complex interactions of human-at-work and enterprise systems should be beneficial to organisations in their quest to remain competitive in a global economy.
A study of surface tension driven segregation in monotectic alloy systems
NASA Technical Reports Server (NTRS)
Andrews, J. Barry; Andrews, Rosalia N.; Gowens, Terrell F.
1988-01-01
The compatibilities of various monotectic alloy systems with several different crucible materials were evaluated. The study was carried out using small candidate alloy samples of compositions that produced fifty volume percent of each liquid phase at the monotectic temperature. Compatibility was based on the evaluation of the wetting tendency of the two immiscible phases with the crucible material in a one-g solidified sample. Three types of wetting phenomena were observed during the evaluation. Type 1 indicates an alloy-crucible combination where the L2 phase preferentially wets the crucible material. Since L2 is usually the minority phase in desirable alloys, this material combination would be difficult to process and is therefore considered incompatible. Type 2 behavior indicates an alloy-crucible combination where the L1 phase preferentially wets the crucible material. This type of combination is considered compatible since surface tension effects should aid in processing the alloy to a useful form. Type 3 indicates any combination that leads to major reactions between the alloy and crucible material, gas entrapment, or separation of the metal from the crucible wall. Additional compatibility evaluations would have to be carried out on combinations of this category. The five alloy systems studied included aluminum-bismuth, copper-lead, aluminum-indium, aluminum-lead and cadmium-gallium. The systems were combined with crucibles of alumina, boron nitride, mullite, quartz, silicon carbide and zirconia.
System Engineering Analysis For Improved Scout Business Information Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Slyke, D. A.
The project uses system engineering principles to address the need of Boy Scout leaders for an integrated system to facilitate advancement and awards records, leader training and planning for meetings and activities. Existing products to address needs of Scout leaders and relevant stakeholders function to support record keeping and some communication functions but opportunity exists for a better system to fully integrate these functions with training delivery and recording, activity planning along with feedback and information gathering from stakeholders. Key stakeholders for the sytem include Scouts and their families, leaders, training providers, sellers of supplies and awards, content generators andmore » facilities that serve Scout activities. Key performance parameters for the system are protection of personal information, availability of current information, information accuracy and information content that has depth. Implementation concepts considered for the system include (1) owned and operated by Boy Scouts of America, (2) Contracted out to a vendor (3) distributed system that functions with BSA managed interfaces. The selected concept is to contract out to a vendor to maximize the likelihood of successful integration and take advantage of the best technology. Development of requirements considers three key use cases (1) System facilitates planning a hike with training needed satisfied in advance and advancement recording real time (2) Scheduling and documenting in-person training, (3) Family interested in Scouting receives information and can request follow-up. Non-functional requirements are analyzed with the Quality Function Deployment tool. Requirement addressing frequency of backup, compatibility with legacy and new technology, language support, software update are developed to address system reliability and intuitive interface. System functions analyzed include update of activity database, maintenance of advancement status, archive of documents, and monitoring of content that is accessible. The study examines risks associated with information security, technological change and continued popularity of Scouting. Mitigation is based on system functions that are defined. The approach to developing an improved system for facilitating Boy Scout leader functions was iterative with insights into capabilities coming in the course of working through the used cases and sequence diagrams.« less
NASA Systems Engineering Handbook
NASA Technical Reports Server (NTRS)
Hirshorn, Steven R.; Voss, Linda D.; Bromley, Linda K.
2017-01-01
The update of this handbook continues the methodology of the previous revision: a top-down compatibility with higher level Agency policy and a bottom-up infusion of guidance from the NASA practitioners in the field. This approach provides the opportunity to obtain best practices from across NASA and bridge the information to the established NASA systems engineering processes and to communicate principles of good practice as well as alternative approaches rather than specify a particular way to accomplish a task. The result embodied in this handbook is a top-level implementation approach on the practice of systems engineering unique to NASA. Material used for updating this handbook has been drawn from many sources, including NPRs, Center systems engineering handbooks and processes, other Agency best practices, and external systems engineering textbooks and guides. This handbook consists of six chapters: (1) an introduction, (2) a systems engineering fundamentals discussion, (3) the NASA program project life cycles, (4) systems engineering processes to get from a concept to a design, (5) systems engineering processes to get from a design to a final product, and (6) crosscutting management processes in systems engineering. The chapters are supplemented by appendices that provide outlines, examples, and further information to illustrate topics in the chapters. The handbook makes extensive use of boxes and figures to define, refine, illustrate, and extend concepts in the chapters.
Information Loss from Technological Progress
NASA Astrophysics Data System (ADS)
Townsend, P. D.
2014-12-01
Progress in electronics and optics offers faster computers, and rapid communication via the internet that is matched by ever larger and evolving storage systems. Instinctively one assumes that this must be totally beneficial. However advances in software and storage media are progressing in ways which are frequently incompatible with earlier systems and the economics and commercial pressures rarely guarantee total compatibility with earlier systems. Instead, the industries actively choose to force the users to purchase new systems and software. Thus we are moving forward with new technological variants that may have access to only the most recent systems and we will have lost earlier alternatives. The reality is that increased processing speed and storage capacity are matched by an equally rapid decline in the access and survival lifetime of older information. This pattern is not limited to modern electronic systems but is evident throughout history from writing on stone and clay tablets to papyrus and paper. It is equally evident in image systems from painting, through film, to magnetic tapes and digital cameras. In sound recording we have variously progressed from wax discs to vinyl, magnetic tape and CD formats. In each case the need for better definition and greater capacity has forced the earlier systems into oblivion. Indeed proposed interactive music systems could similarly relegate music CDs to specialist collections. The article will track some of the examples and discuss the consequences as well as noting that this information loss is further compounded by developments in language and changes in cultural views of different societies.
Pizzuti, A; Baralis, G; Bassignana, A; Antonielli, E; Di Leo, M
1997-01-01
The MS200 Cardioscope, from MRT Micro as., Norway, is a 12 channel ECG card to be directly inserted into a standard personal computer (PC). The standard ISA Bus compatible half length card comes with a set of 10 cables with electrodes and the software for recording, displaying and saving ECG signals. The system is supplied with DOS or Windows software. The goal of the present work was to evaluate the affordability and usability of the MS200 in a clinical setting. We tested the 1.5 DOS version of the software. In 30 patients with various cardiac diseases the ECG signal has been recorded with MS200 and with standard Hellige CardioSmart equipment. The saved ECGs were recalled and printed using an Epson Stylus 800 ink-jet printer. Two cardiologists reviewed the recordings for a looking at output quality, amplitude and speed precision, artifacts, etc. 1) Installation: the card has proven to be totally compatible with the hardware; no changes in default settings had to be made. 2) Usage: the screens are clear; the commands and menus are intuitive and easy to use. Due to the boot-strap and software loading procedures and, most important, off-line printing, the time needed to obtain a complete ECG printout has been longer than that of the reference machine. 3) Archiving and retrieval of ECG: the ECG curves can be saved in original or compressed form: selecting the latter, the noise and non-ECG information is filtered away and the space consumption on disk is reduced: on average, 20 Kb are needed for 10 seconds of signal. The MS200 can be run on a Local Area Network and is prepared for integrating with an existing informative system: we are currently testing the system in this scenery. 4) MS200 includes options for on-line diagnosis, a technology we have not tested in the present work. 5) The only setting allowed for printing full pages is letter size (A4): the quality of printouts is good, with a resolution of 180 DPI. In conclusion, the MS200 system seems reliable and safe. In the configuration we tested, it cannot substitute a dedicated ECG equipment: from this point of view, a smaller PCMCIA-type card with a battery-operated notebook PC will be more suitable for clinical uses. Nevertheless, the possibility to log and track ECG records, integrated into the department informative system, may provide a valuable tool for improving access to medical information.
Compatibility of refractory materials for nuclear reactor poison control systems
NASA Technical Reports Server (NTRS)
Sinclair, J. H.
1974-01-01
Metal-clad poison rods have been considered for the control system of an advanced space power reactor concept studied at the NASA Lewis Research Center. Such control rods may be required to operate at temperatures of about 140O C. Selected poison materials (including boron carbide and the diborides of zirconium, hafnium, and tantalum) were subjected to 1000-hour screening tests in contact with candidate refractory metal cladding materials (including tungsten and alloys of tantalum, niobium, and molybdenum) to assess the compatibility of these materials combinations at the temperatures of interest. Zirconium and hafnium diborides were compatible with refractory metals at 1400 C, but boron carbide and tantalum diboride reacted with the refractory metals at this temperature. Zirconium diboride also showed promise as a reaction barrier between boron carbide and tungsten.
Interactive graphics system for IBM 1800 computer
NASA Technical Reports Server (NTRS)
Carleton, T. P.; Howell, D. R.; Mish, W. H.
1972-01-01
A FORTRAN compatible software system that has been developed to provide an interactive graphics capability for the IBM 1800 computer is described. The interactive graphics hardware consists of a Hewlett-Packard 1300A cathode ray tube, Sanders photopen, digital to analog converters, pulse counter, and necessary interface. The hardware is available from IBM as several related RPQ's. The software developed permits the application programmer to use IBM 1800 FORTRAN to develop a display on the cathode ray tube which consists of one or more independent units called pictures. The software permits a great deal of flexibility in the manipulation of these pictures and allows the programmer to use the photopen to interact with the displayed data and make decisions based on information returned by the photopen.
NASA Astrophysics Data System (ADS)
Gao, Anran; Lu, Na; Dai, Pengfei; Fan, Chunhai; Wang, Yuelin; Li, Tie
2014-10-01
Sensitive and quantitative analysis of proteins is central to disease diagnosis, drug screening, and proteomic studies. Here, a label-free, real-time, simultaneous and ultrasensitive prostate-specific antigen (PSA) sensor was developed using CMOS-compatible silicon nanowire field effect transistors (SiNW FET). Highly responsive n- and p-type SiNW arrays were fabricated and integrated on a single chip with a complementary metal oxide semiconductor (CMOS) compatible anisotropic self-stop etching technique which eliminated the need for a hybrid method. The incorporated n- and p-type nanowires revealed complementary electrical response upon PSA binding, providing a unique means of internal control for sensing signal verification. The highly selective, simultaneous and multiplexed detection of PSA marker at attomolar concentrations, a level useful for clinical diagnosis of prostate cancer, was demonstrated. The detection ability was corroborated to be effective by comparing the detection results at different pH values. Furthermore, the real-time measurement was also carried out in a clinically relevant sample of blood serum, indicating the practicable development of rapid, robust, high-performance, and low-cost diagnostic systems.Sensitive and quantitative analysis of proteins is central to disease diagnosis, drug screening, and proteomic studies. Here, a label-free, real-time, simultaneous and ultrasensitive prostate-specific antigen (PSA) sensor was developed using CMOS-compatible silicon nanowire field effect transistors (SiNW FET). Highly responsive n- and p-type SiNW arrays were fabricated and integrated on a single chip with a complementary metal oxide semiconductor (CMOS) compatible anisotropic self-stop etching technique which eliminated the need for a hybrid method. The incorporated n- and p-type nanowires revealed complementary electrical response upon PSA binding, providing a unique means of internal control for sensing signal verification. The highly selective, simultaneous and multiplexed detection of PSA marker at attomolar concentrations, a level useful for clinical diagnosis of prostate cancer, was demonstrated. The detection ability was corroborated to be effective by comparing the detection results at different pH values. Furthermore, the real-time measurement was also carried out in a clinically relevant sample of blood serum, indicating the practicable development of rapid, robust, high-performance, and low-cost diagnostic systems. Electronic supplementary information (ESI) available: Electrical characterization of fabricated n- and p-type nanowires, and influence of Debye screening on PSA sensing. See DOI: 10.1039/c4nr03210a
Primer on computers and information technology. Part two: an introduction to computer networking.
Channin, D S; Chang, P J
1997-01-01
Computers networks are a way of connecting computers together such that they can exchange information. For this exchange to be successful, system behavior must be planned and specified very clearly at a number of different levels. Although there are many choices to be made at each level, often there are simple decisions that can be made to rapidly reduce the number of options. Planning is most important at the highest (application) and lowest (wiring) levels, whereas the middle levels must be specified to ensure compatibility. Because of the widespread use of the Internet, solutions based on Internet technologies are often cost-effective and should be considered when designing a network. As in all technical fields, consultation with experts (ie, computer networking specialists) may be worthwhile.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... information provided. FOR FURTHER INFORMATION CONTACT: Nathan K. Greenwell, Mathematical Statistician, Evaluation Division, NVS-431, National Center for Statistics and Analysis, National Highway Traffic Safety... you to send a copy to Nathan K. Greenwell, Mathematical Statistician, Evaluation Division, NVS-431...
Tung, Feng-Cheng; Chang, Su-Chao; Chou, Chi-Min
2008-05-01
Ever since National Health Insurance was introduced in 1995, the number of insurants increased to over 96% from 50 to 60%, with a continuous satisfaction rating of about 70%. However, the premium accounted for 5.77% of GDP in 2001 and the Bureau of National Health Insurance had pressing financial difficulties, so it reformed its expenditure systems, such as fee for service, capitation, case payment and the global budget system in order to control the rising medical costs. Since the change in health insurance policy, most hospitals attempted to reduce their operating expenses and improve efficiency. Introducing the electronic logistics information system is one way of reducing the cost of the department of central warehouse and the nursing stations. Hence, the study proposes a technology acceptance research model and examines how nurses' acceptance of the e-logistics information system has been affected in the medical industry. This research combines innovation diffusion theory, technology acceptance model and added two research parameters, trust and perceived financial cost to propose a new hybrid technology acceptance model. Taking Taiwan's medical industry as an experimental example, this paper studies nurses' acceptance of the electronic logistics information system. The structural equation modeling technique was used to evaluate the causal model and confirmatory factor analysis was performed to examine the reliability and validity of the measurement model. The results of the survey strongly support the new hybrid technology acceptance model in predicting nurses' intention to use the electronic logistics information system. The study shows that 'compatibility', 'perceived usefulness', 'perceived ease of use', and 'trust' all have great positive influence on 'behavioral intention to use'. On the other hand 'perceived financial cost' has great negative influence on behavioral intention to use.
Lisiecka-Biełanowicz, Mira; Wawrzyniak, Zbigniew
2016-07-15
The healthcare system is positioned in the patient's environment and works with other determinants of the treatment. Patient care requires a whole system compatible to the needs of organizational and technical solutions. The purpose of this study is to present a new model of patient-oriented care, in which the use of information and communication technology (ICT) can improve the effectiveness of healthcare for patients with chronic diseases. The study material is the process of healthcare for chronically ill patients. Knowledge of the circumstances surrounding ecosystem and of the patients' needs, taking into account the fundamental healthcare goals allows us to build a new models of care, starting with the economic assumptions. The method used is modeling the construction of efficient healthcare system with the patient-centered model using ICT tools. We present a new systemic concept of building patient's environment in which he is the central figure of the healthcare organization - so called patient centered system. The use of ICT in the model of chronic patient's healthcare can improve the effectiveness of this kind of care. The concept is a vision to making wide platform of information management in chronic disease in a real environment ecosystem of patient using ICT tools. On the basis of a systematic approach to the model of chronic disease, and the knowledge of the patient itself, a model of the ecosystem impacts and interactions through information feedback and the provision of services can be constructed. ICT assisted techniques will increase the effectiveness of patient care, in which nowadays information exchange plays a key role.
ICT use for information management in healthcare system for chronic disease patient
NASA Astrophysics Data System (ADS)
Wawrzyniak, Zbigniew M.; Lisiecka-Biełanowicz, Mira
2013-10-01
Modern healthcare systems are designed to fulfill needs of the patient, his system environment and other determinants of the treatment with proper support of technical aids. A whole system of care is compatible to the technical solutions and organizational framework based on legal rules. The purpose of this study is to present how can we use Information and Communication Technology (ICT) systemic tools in a new model of patient-oriented care, improving the effectiveness of healthcare for patients with chronic diseases. The study material is the long-term process of healthcare for patients with chronic illness. Basing on the knowledge of the whole circumstances of patient's ecosystem and his needs allow us to build a new ICT model of long term care. The method used is construction, modeling and constant improvement the efficient ICT layer for the patient-centered healthcare model. We present a new constructive approach to systemic process how to use ICT for information management in healthcare system for chronic disease patient. The use of ICT tools in the model for chronic disease can improve all aspects of data management and communication, and the effectiveness of long-term complex healthcare. In conclusion: ICT based model of healthcare can be constructed basing on the interactions of ecosystem's functional parts through information feedback and the provision of services and models as well as the knowledge of the patient itself. Systematic approach to the model of long term healthcare assisted functionally by ICT tools and data management methods will increase the effectiveness of patient care and organizational efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Natesan, K.; Momozaki, Y.; Li, M.
This report gives a description of the activities in design, fabrication, construction, and assembling of a pumped sodium loop for the sodium compatibility studies on advanced structural materials. The work is the Argonne National Laboratory (ANL) portion of the effort on the work project entitled, 'Sodium Compatibility of Advanced Fast Reactor Materials,' and is a part of Advanced Materials Development within the Reactor Campaign. The objective of this project is to develop information on sodium corrosion compatibility of advanced materials being considered for sodium reactor applications. This report gives the status of the sodium pumped loop at Argonne National Laboratory,more » the specimen details, and the technical approach to evaluate the sodium compatibility of advanced structural alloys. This report is a deliverable from ANL in FY2010 (M2GAN10SF050302) under the work package G-AN10SF0503 'Sodium Compatibility of Advanced Fast Reactor Materials.' Two reports were issued in 2009 (Natesan and Meimei Li 2009, Natesan et al. 2009) which examined the thermodynamic and kinetic factors involved in the purity of liquid sodium coolant for sodium reactor applications as well as the design specifications for the ANL pumped loop for testing advanced structural materials. Available information was presented on solubility of several metallic and nonmetallic elements along with a discussion of the possible mechanisms for the accumulation of impurities in sodium. That report concluded that the solubility of many metals in sodium is low (<1 part per million) in the temperature range of interest in sodium reactors and such trace amounts would not impact the mechanical integrity of structural materials and components. The earlier report also analyzed the solubility and transport mechanisms of nonmetallic elements such as oxygen, nitrogen, carbon, and hydrogen in laboratory sodium loops and in reactor systems such as Experimental Breeder Reactor-II, Fast Flux Test Facility, and Clinch River Breeder Reactor. Among the nonmetallic elements discussed, oxygen is deemed controllable and its concentration in sodium can be maintained in sodium for long reactor life by using cold-trap method. It was concluded that among the cold-trap and getter-trap methods, the use of cold trap is sufficient to achieve oxygen concentration of the order of 1 part per million. Under these oxygen conditions in sodium, the corrosion performance of structural materials such as austenitic stainless steels and ferritic steels will be acceptable at a maximum core outlet sodium temperature of {approx}550 C. In the current sodium compatibility studies, the oxygen concentration in sodium will be controlled and maintained at {approx}1 ppm by controlling the cold trap temperature. The oxygen concentration in sodium in the forced convection sodium loop will be controlled and monitored by maintaining the cold trap temperature in the range of 120-150 C, which would result in oxygen concentration in the range of 1-2 ppm. Uniaxial tensile specimens are being exposed to flowing sodium and will be retrieved and analyzed for corrosion and post-exposure tensile properties. Advanced materials for sodium exposure include austenitic alloy HT-UPS and ferritic-martensitic steels modified 9Cr-1Mo and NF616. Among the nonmetallic elements in sodium, carbon was assessed to have the most influence on structural materials since carbon, as an impurity, is not amenable to control and maintenance by any of the simple purification methods. The dynamic equilibrium value for carbon in sodium systems is dependent on several factors, details of which were discussed in the earlier report. The current sodium compatibility studies will examine the role of carbon concentration in sodium on the carburization-decarburization of advanced structural materials at temperatures up to 650 C. Carbon will be added to the sodium by exposure of carbon-filled iron tubes, which over time will enable carbon to diffuse through iron and dissolve into sodium. The method enables addition of dissolved carbon (without carbon particulates) in sodium that is of interest for materials compatibility evaluation. The removal of carbon from the sodium will be accomplished by exposing carbon-gettering alloys such as refractory metals that have a high partitioning coefficient for carbon and also precipitate carbides, thereby decreasing the carbon concentration in sodium.« less