A complete electrical shock hazard classification system and its application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Lloyd; Cartelli, Laura; Graham, Nicole
Current electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. As a result, this leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. We find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50/60 Hz power. This paper proposes a method of classifying allmore » of the electrical shock hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Lastly, the new comprehensive electrical shock hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards.« less
A complete electrical shock hazard classification system and its application
Gordon, Lloyd; Cartelli, Laura; Graham, Nicole
2018-02-08
Current electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. As a result, this leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. We find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50/60 Hz power. This paper proposes a method of classifying allmore » of the electrical shock hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Lastly, the new comprehensive electrical shock hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards.« less
A study of some features of ac and dc electric power systems for a space station
NASA Technical Reports Server (NTRS)
Hanania, J. I.
1983-01-01
This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.
A fuzzy set approach for reliability calculation of valve controlling electric actuators
NASA Astrophysics Data System (ADS)
Karmachev, D. P.; Yefremov, A. A.; Luneva, E. E.
2017-02-01
The oil and gas equipment and electric actuators in particular frequently perform in various operational modes and under dynamic environmental conditions. These factors affect equipment reliability measures in a vague, uncertain way. To eliminate the ambiguity, reliability model parameters could be defined as fuzzy numbers. We suggest a technique that allows constructing fundamental fuzzy-valued performance reliability measures based on an analysis of electric actuators failure data in accordance with the amount of work, completed before the failure, instead of failure time. Also, this paper provides a computation example of fuzzy-valued reliability and hazard rate functions, assuming Kumaraswamy complementary Weibull geometric distribution as a lifetime (reliability) model for electric actuators.
46 CFR 169.662 - Hazardous locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Hazardous locations. 169.662 Section 169.662 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and Electrical Electrical § 169.662 Hazardous locations. Electrical equipment must not be...
Manned spacecraft electrical fire safety
NASA Technical Reports Server (NTRS)
Wardell, A. W.
1971-01-01
The fire hazards created in spacecraft compartments by malfunction of electrical wiring are described. The tests for electrical wire/cable current overload flammability are presented. The application of electrical and material technologies to the reduction of fire hazards in spacecraft are examined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holdren, J.P.
The need for fusion energy depends strongly on fusion's potential to achieve ambitious safety goals more completely or more economically than fission can. The history and present complexion of public opinion about environment and safety gives little basis for expecting either that these concerns will prove to be a passing fad or that the public will make demands for zero risk that no energy source can meet. Hazard indices based on ''worst case'' accidents and exposures should be used as design tools to promote combinations of fusion-reactor materials and configurations that bring the worst cases down to levels small comparedmore » to the hazards people tolerate from electricity at the point of end use. It may well be possible, by building such safety into fusion from the ground up, to accomplish this goal at costs competitive with other inexhaustible electricity sources. Indeed, the still rising and ultimately indeterminate costs of meeting safety and environmental requirements in nonbreeder fission reactors and coal-burning power plants mean that fusion reactors meeting ambitious safety goals may be able to compete economically with these ''interim'' electricity sources as well.« less
Electric furnace dust: Can you bury the hazard?
DOE Office of Scientific and Technical Information (OSTI.GOV)
McManus, G.J.
1996-04-01
Electric furnace waste treatment is moving into high gear, but the exact direction is unclear. On one hand, there is a trend toward complete recycling of the dust captured in furnace baghouses. Iron units as well as zinc and other elements are being reclaimed. On the other side, recent actions by regulators indicate recycling may not be required at all. With the correct chemical stabilization, it appears, dust may simply be placed in ordinary landfill. This paper describes three processes for waste treatment of furnace dust: Super Detox, a process for zinc removal from galvanized scrap before melting, and themore » INMETCO process.« less
The 1991 International Aerospace and Ground Conference on Lightning and Static Electricity, volume 1
NASA Technical Reports Server (NTRS)
1991-01-01
The proceedings of the 1991 International Aerospace and Ground Conference on Lightning and Static Electricity are reported. Some of the topics covered include: lightning, lightning suppression, aerospace vehicles, aircraft safety, flight safety, aviation meteorology, thunderstorms, atmospheric electricity, warning systems, weather forecasting, electromagnetic coupling, electrical measurement, electrostatics, aircraft hazards, flight hazards, meteorological parameters, cloud (meteorology), ground effect, electric currents, lightning equipment, electric fields, measuring instruments, electrical grounding, and aircraft instruments.
Down to Earth with an electric hazard from space
Love, Jeffrey J.; Bedrosian, Paul A.; Schultz, Adam
2017-01-01
In reaching across traditional disciplinary boundaries, solid-Earth geophysicists and space physicists are forging new collaborations to map magnetic-storm hazards for electric-power grids. Future progress in evaluation storm time geoelectric hazards will come primarily through monitoring, surveys, and modeling of related data.
Positive Voltage Hazard to EMU Crewman from Currents through Plasma
NASA Astrophysics Data System (ADS)
Kramer, Leonard; Hamilton, Doug; Mikatarian, Ronald; Thomas, Joseph; Koontz, Steven
2010-09-01
The International Space Station(ISS) in its transit through the ionosphere experiences a variable electrical potential between its bonded structure and the overlying ionospheric plasma. The 160 volt solar arrays on ISS are grounded negative and drive structure to negative floating potential(FP) relative to plasma. This potential is a result of the asymmetric collection properties of currents from ions and electrons moderated by geomagnetic; so called v Å~ B induction distributing an additional 20 volts both positive and negative across ISS’s main structural truss element. Since the space suit or extravehicular mobility unit(EMU) does not protect the crewperson from electrical shock, during extra vehicular activity(EVA) the person is exposed to a hazard from the potential when any of the several metallic suit penetrations come in direct contact with ISS structure. The moisture soaked garment worn by the crewperson and the large interior metal contact areas facilitate currents through the crewperson’s body. There are two hazards; Negative and Positive FP. The Negative hazard is the better known risk created by a shock hazard from arcing of anodized material on the EMU. Negative hazard has been controlled by plasma contactor units(PCU) containing a reserve of Xenon gas which is expelled from ISS. The PCU provide a ground path for the negative charge from the structure to flow to exterior plasma bringing ISS FP closer to zero. The understanding has now emerged that the operation of PCUs to protect the crewmen from negative voltage exposes him to low to moderate positive voltage(≤15V). Positive voltage is also a hazard as it focuses electrons onto exposed metal EMU penetrations completing a circuit from plasma through interior contact with the moist crewman’s body and on to ISS ground through any of several secondary isolated metal penetrations. The resulting direct current from positive voltage exposure is now identified as an electrical shock hazard. This paper describes the model of the EMU with a human body in the circuit that has been used by NASA to evaluate the low positive voltage hazard. The model utilizes the electron collection characterization from on orbit Langmuir probe data as representative of electron collection to a positive charged surface with a wide range of on orbit plasma temperature and density conditions. The data has been unified according to nonlinear theoretical temperature and density variation of the electron saturated probe current collection theory and used as a model for the electron collection at EMU surfaces. Vulnerable paths through the EMU connecting through the crewman’s body have been identified along with electrical impedance of the exposed body parts. The body impedance information is merged with the electron collection characteristics in circuit simulation software known as SPICE. The assessment shows that currents can be on the order of 20 mA for a 15 V exposure and of order 4 mA at 3V. These currents formally violate NASA protocol for electric current exposures. However the human factors associated with subjective consequences of noxious stimuli from low voltage exposure during the stressful conditions of EVA are an area of active inquiry.
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
78 FR 37760 - Electrical Equipment in Hazardous Locations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-24
... floating facilities engaged in OCS activities, however, equipment could be installed in hazardous locations... composition and the extent of equipment replacement. The myriad types of MODUs and facilities operating on the.... USCG-2012-0850] RIN 1625-AC00 Electrical Equipment in Hazardous Locations AGENCY: Coast Guard, DHS...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards... of cap lamp batteries: 100 amperes for a 4-volt battery; 75 amperes for a 6-volt battery; 50 amperes...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, F.A.
1983-10-01
In August 1980, the National Institute for Occupational Safety and Health (NIOSH) received a request from the International Brotherhood of Electrical Workers Local 1600 for a Health Hazard Evaluation at the Pennsylvania Power and Light Company's Martins Creek Steam Electric Station in Martins Creek, Pennsylvania. The union was concerned about potential health and explosion hazards to employees from coal dust in Units 1 and 2 and the coal field. Based on environmental studies conducted at the time of the survey, NIOSH has determined that a potential health hazard may have existed due to exposure to respirable coal dust and quartz.more » Recommendations were made to ensure that potential health and explosion hazards are avoided in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Camp
Over the past four years, the Electrical Safety Program at PPPL has evolved in addressing changing regulatory requirements and lessons learned from accident events, particularly in regards to arc flash hazards and implementing NFPA 70E requirements. This presentation will discuss PPPL's approaches to the areas of electrical hazards evaluation, both shock and arc flash; engineered solutions for hazards mitigation such as remote racking of medium voltage breakers, operational changes for hazards avoidance, targeted personnel training and hazard appropriate personal protective equipment. Practical solutions for nominal voltage identification and zero voltage checks for lockout/tagout will also be covered. Finally, we willmore » review the value of a comprehensive electrical drawing program, employee attitudes expressed as a personal safety work ethic, integrated safety management, and sustained management support for continuous safety improvement.« less
Firefighter safety and photovoltaic installations research project
NASA Astrophysics Data System (ADS)
Backstrom, Robert; Dini, Dave
2012-10-01
Under the United States Department of Homeland Security (DHS) Assistance to Fire Fighters grant, UL LLC examined fire service concerns of photovoltaic (PV) systems. These concerns included firefighter vulnerability to electrical and casualty hazards when mitigating a fire involving photovoltaic (PV) modules systems. Findings include: 1. The electric shock hazard due to application of water is dependent on voltage, water conductivity, distance and spray pattern of the suppression stream. 2. Outdoor weather exposure rated electrical enclosures are not resistant to water penetration by fire hose streams. 3. Firefighter's gloves and boots afford limited protection against electrical shock provided the insulating surface is intact and dry. 4. "Turning off" an array is not a simple matter of opening a disconnect switch. 5. Tarps offer varying degrees of effectiveness. 6. Fire equipment scene lighting and exposure fires may illuminate PV systems sufficiently to cause a lock-on hazard. 7. Severely damaged PV arrays are capable of producing hazardous conditions. 8. Damage to modules from tools may result in both electrical and fire hazards. 9. Severing of conductors in both metal and plastic conduit results in electrical and fire hazards. 10. Responding personnel must stay away from the roofline in the event of modules or sections of an array sliding off the roof. 11. Fires under an array but above the roof may breach roofing materials and decking allowing fire to propagate into the attic space. Several tactical considerations were developed utilizing the data from the experiments.
Front-Line Resilience Perspectives: The Electric Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finster, M.; Phillips, J.; Wallace, K.
2016-11-01
This report seeks to summarize how states and local utility companies are approaching all-hazards resilience in planning, construction, operations, and maintenance of the electric system, as well as challenges faced when addressing all-hazards resilience.
Medical aspects of power generation, present and future.
Linnemann, R E
1979-01-01
It can be seen that the radiation emissions of nuclear power plants are small indeed, compared to natural background radiation and other man-made sources of radiation. For example, the poulation is exposed to 100 times more radiation from television sets than from nuclear power reactors. The assumed risks to the people in this country from nuclear power reactors are also small compared to the normal risks which are tolerated in this society. The complete elimination of all hazards is a most difficult if not impossible task. If we need and desire a certain level of electrical energy, if we must choose between alternative sourves of the energy, then it is apparent that the total impact on our health from nuclear power generation of electricity, under normal operations and in consideration of catastrophic accident probabilities, is significantly less than that of continuing or increasing use of fossil fuels to generate electricity.
Effects of carbon fibers on consumer products
NASA Technical Reports Server (NTRS)
Wise, R. A.; Lovett, C. D.
1980-01-01
The potential effects of carbon fibers on consumer products such as dishwashers, microwave ovens, and smoke detectors were investigated. The investigation was divided into two categories to determine the potential faults and hazards that could occur if fibers should enter the electrical circuits of the selected appliances. The categories were a fault analysis and a hazard analysis. Hazards considered were fire, flood, physical harm, explosion, and electrical shock. Electrical shock was found to be a possible occurrence related to carbon fibers. Faults were considered to be any effect on the performance of an appliance which would result in complaint or require service action.
International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update
NASA Technical Reports Server (NTRS)
Hernandez-Pellerano, Amri; Iannello, Christopher J.; Garrett, Henry B.; Ging, Andrew T.; Katz, Ira; Keith, R. Lloyd; Minow, Joseph I.; Willis, Emily M.; Schneider, Todd A.; Whittlesey, Edward J.;
2014-01-01
The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the space environment forecast input to the ISS charging model indicates floating potentials (FP) within specified limits. These recommendations were based on the persistence of conditions in the space environment due to the current low solar cycle and belief in the accuracy and completeness of the ISS charging model. Subsequently, a Noncompliance Report (NCR), ISS-NCR-232G, Lack of Two-fault Tolerance to EVA Crew Shock in the Low Earth Orbit Plasma Environment, was signed in September 2013 specifying new guidelines for the use of shock hazard controls based on a forecast of the space environment from ISS plasma measurements taken prior to the EVA [ISS-EVA-312-AC, 2012]. This NESC assessment re-evaluates EVA charging hazards through a process that is based on over 14 years of ISS operations, charging measurements, laboratory tests, EMU studies and modifications, and safety reports. The assessment seeks an objective review of the plasma charging hazards associated with EVA operations to determine if any of the present hazard controls can safely change the PCU utilization plan to allow more flexibility in ISS operations during EVA preparation and execution.
Code of Federal Regulations, 2014 CFR
2014-10-01
... HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous... cargoes. (a) This section applies to locations surrounding the storage and handling of combustible liquid... hazardous locations in § 111.106-9 of this subpart apply. ...
Carbon/graphite composite material study, appendix A and appendix B
NASA Technical Reports Server (NTRS)
1981-01-01
A comprehensive assessment of the possible damage to electrical and electronic equipment caused by accidental release of carbon fibers from burning civil aircraft with carbon composite parts was completed. The study concluded that the amount of fiber likely to be released is much lower than initially predicted. Carbon fiber released from an aircraft crash fire was found (from atmospheric dissemination models) to disperse over a much larger area than originally estimated, with correspondingly lower fiber concentrations. Long term redissemination of fiber was shown to be insignificant if reasonable care is exercised in accident cleanup. The vulnerability of electrical equipment to structural fibers in current use was low. Consumer appliances, industrial electronics, and avionics were essentially invulnerable to carbon fibers. Shock hazards (and thus potential injury or death) were found to be extremely unlikely.
Electromagnetic Radiation Hazards Testing for Non-Ionizing Radio Frequency Transmitting Equipment
2012-12-19
Hazards of Electromagnetic Radiation to Ordnance (HERO), Personnel (HERP), and Fuel (HERF) protection guidance for intentional non-ionizing Radio...HERO Hazards of Electromagnetic Radiation to Ordnance HERP Hazards of Electromagnetic Radiation to Personnel IEEE Institute of Electrical and...Systems Command Technical Manual, Electromagnetic Radiation Hazards ( Hazards to Ordnance ), 1 July 2008.
NASA Technical Reports Server (NTRS)
1991-01-01
Lightning Technologies, Inc., Pittsfield, MA, - a spinoff company founded by president J. Anderson Plumer, a former NASA contractor employee who developed his expertise with General Electric Company's High Voltage Laboratory - was a key player in Langley Research Center's Storm Hazards Research Program. Lightning Technologies used its NASA acquired experience to develop protective measures for electronic systems and composite structures on aircraft, both of which are particularly susceptible to lightning damage. The company also provides protection design and verification testing services for complete aircraft systems or individual components. Most aircraft component manufacturers are among Lightning Technologies' clients.
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
30 CFR 46.11 - Site-specific hazard awareness training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... environmental conditions, recognition and avoidance of hazards such as electrical and powered-haulage hazards, traffic patterns and control, and restricted areas; and warning and evacuation signals, evacuation and...
Electrical Arc Ignition Testing for Constellation Program
NASA Technical Reports Server (NTRS)
Sparks, Kyle; Gallus, Timothy; Smith, Sarah
2009-01-01
NASA Johnson Space Center (JSC) Materials and Processes Branch requested that NASA JSC White Sands Test Facility (WSTF) perform testing for the Constellation Program to evaluate the hazard of electrical arc ignition of materials that could be in close proximity to batteries. Specifically, WSTF was requested to perform wire-break electrical arc tests to determine the current threshold for ignition of generic cotton woven fabric samples with a fixed voltage of 3.7 V, a common voltage for hand-held electrical devices. The wire-break test was developed during a previous test program to evaluate the hazard of electrical arc ignition inside the Extravehicular Mobility Unit [1].
SEE Design Guide and Requirements for Electrical Deadfacing
NASA Technical Reports Server (NTRS)
Berki, Joe M.; Sargent, Noel; Kauffman, W. (Technical Monitor)
2002-01-01
The purpose of this design guide is to present information for understanding and mitigating the potential hazards associated with de-mating and mating powered electrical connectors on space flight vehicles. The process of staging is a necessary function in the launching of space vehicles and in the deployment of satellites, and now in manned assembly of systems in space. During this electrical interconnection process, various environments may be encountered that warrant the restriction of the voltage and current present across the pins of an electrical connector prior to separation, mating, or in a static open non-mated configuration. This process is called deadfacing. These potentially hazardous environments encompass the obvious explosive fuel vapors and human shock hazard, to multiple Electro-Magnetic Interference (EMI) phenomena related to the rapid rate of change in current as well as exposure to Radio Frequency (RF) fields.
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2013 CFR
2013-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
NASA Technical Reports Server (NTRS)
Downs, W. R.
1976-01-01
The potential flammability hazard when a water/glycol solution contacts defectively insulated silver-clad copper circuitry or electrical components carrying a direct current is described. The chemical reactions and means for detecting them are explained. Methods for detecting and cleaning contaminated areas and the use of inhibitors to arrest chemical reactivity are also explained. Preventive measures to minimize hazards are given. Photomicrographs of the chemical reactions occurring on silver clad wires are also included.
Magnetic storms and induction hazards
Love, Jeffrey J.; Rigler, E. Joshua; Pulkkinen, Antti; Balch, Christopher
2014-01-01
Magnetic storms are potentially hazardous to the activities and technological infrastructure of modern civilization. This reality was dramatically demonstrated during the great magnetic storm of March 1989, when surface geoelectric fields, produced by the interaction of the time-varying geomagnetic field with the Earth's electrically conducting interior, coupled onto the overlying Hydro-Québec electric power grid in Canada. Protective relays were tripped, the grid collapsed, and about 9 million people were temporarily left without electricity [Bolduc, 2002].
Thermoacoustic energy effects in electrical arcs.
Capelli-Schellpfeffer, M; Miller, G H; Humilier, M
1999-10-30
Electrical arcs commonly occur in electrical injury incidents. Historically, safe work distances from an energized surface along with personal barrier protection have been employee safety strategies used to minimize electrical arc hazard exposures. Here, the two-dimensional computational simulation of an electrical arc explosion is reported using color graphics to depict the temperature and acoustic force propagation across the geometry of a hypothetical workroom during a time from 0 to 50 ms after the arc initiation. The theoretical results are compared to the experimental findings of staged tests involving a mannequin worker monitored for electrical current flow, temperature, and pressure, and reported data regarding neurologic injury thresholds. This report demonstrates a credible link between electrical explosions and the risk for pressure (acoustic) wave trauma. Our ultimate goal is to protect workers through the design and implementation of preventive strategies that properly account for all electrical arc-induced hazards, including electrical, thermal, and acoustic effects.
The Collision Auto Repair Safety Study (CARSS): a health and safety intervention.
Parker, David L; Bejan, Anca; Brosseau, Lisa M; Skan, Maryellen; Xi, Min
2015-01-01
Collision repair employs approximately 205,500 people in 33,400 shops. Workers are exposed to a diverse array of chemical, physical, and ergonomic hazards. CARSS was based on a random and purposeful sample. Baseline and one baseline and one-year evaluations consisted of 92 questions addressing issues, such as Right-to-Know, fire protection, painting-related hazards, ergonomics, electrical safety, and personal protective equipment. Owners received a report and selected at least 30% of items found deficient for remediation. In-person and web-based services were provided. Forty-nine shops were evaluated at baseline and 45 at follow-up. At baseline, 54% of items were present. This improved to 71% at follow-up (P < 0.0001). Respiratory protection improved 37% (P < 0.0001) and Right-to-Know training increased 30% (P < 0.0001). Owners completed 61% of items they selected for remediation. Small businesses' interventions should address the lack of personnel and administrative infrastructure. Tailored information regarding hazards and easy-to-use training and administrative programs overcome many barriers to improvement. © 2014 Wiley Periodicals, Inc.
Hazardous Waste Cleanup: Amphenol Corporation-Benedix Connector Division in Sidney, New York
Amphenol Corporation is primarily a manufacturer of electrical components and connectors for the aircraft and aerospace industries. Hazardous wastes are generated through electroplating, vapor degreasing and parts-cleaning operations. Hazardous waste
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
Electromagnetic Spectrum Test and Evaluation Process
2010-01-01
HERO , hazards of electromagnetic radiation to ordnance ; HERP, hazards of electromagnetic radiation to personnel; HERF, hazards of electromagnetic ... electromagnetic pulse (EMP); electronic protection; electrostatic dis- charge (ESD); hazards of electromagnetic radi- ation to personnel (HERP), ordnance ...including ordnance containing electrically initiated devices, to be mutually compatible in their intended
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
1986-03-01
Dietzmann L.R. Smith Engines, Emissions, and Vehicle Research Division Southwest Research Institute San Antonio, Texas Prepared for Belvoir Fuels and...replacing the currently used electric forklift with diesel engine-powered forklifts in handling hazardous materials. Electric -powered forklifts have no...diesel engines considered as potential candidates for forklift vehicles used to handle hazardous materials. The first program was conducted to
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility...-fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired...
Concrete decontamination by Electro-Hydraulic Scabbling (EHS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-11-01
EHS is being developed for decontaminating concrete structures from radionuclides, organic substances, and hazardous metals. EHS involves the generation of powerful shock waves and intense cavitation by a strong pulsed electric discharge in a water layer at the concrete surface; high impulse pressure results in stresses which crack and peel off a concrete layer of controllable thickness. Scabbling produces contaminated debris of relatively small volume which can be easily removed, leaving clean bulk concrete. Objective of Phase I was to prove the technical feasibility of EH for controlled scabbling and decontamination of concrete. Phase I is complete.
NASA Astrophysics Data System (ADS)
Sharifi Mood, M.; Olsen, M. J.; Gillins, D. T.; Javadnejad, F.
2016-12-01
The Cascadia Subduction Zone (CSZ) has the ability to generate earthquake as powerful as 9 moment magnitude creating great amount of damage to structures and facilities in Oregon. Series of deterministic earthquake analysis are performed for M9.0, M8.7, M8.4 and M8.1 presenting persistent, long lasting shaking associated with other geological threats such as ground shaking, landslides, liquefaction-induced ground deformations, fault rupture vertical displacement, tsunamis, etc. These ground deformation endangers urban structures, foundations, bridges, roadways, pipelines and other lifelines. Lifeline providers in Oregon, including private and public practices responsible for transportation, electric and gas utilities, water and wastewater, fuel, airports, and harbors face an aging infrastructure that was built prior to a full understanding of this extreme seismic risk. As recently experienced in Chile and Japan, a three to five minutes long earthquake scenario, expected in Oregon, necessities a whole different method of risk mitigation for these major lifelines than those created for shorter shakings from crustal earthquakes. A web-based geographic information system tool is developed to fully assess the potential hazard from the multiple threats impending from Cascadia subduction zone earthquakes in the region. The purpose of this website is to provide easy access to the latest and best available hazard information over the web, including work completed in the recent Oregon Resilience Plan (ORP) (OSSPAC, 2013) and other work completed by the Department of Geology and Mineral Industries (DOGAMI) and the United States Geological Survey (USGS). As a result, this tool is designated for engineers, planners, geologists, and others who need this information to help make appropriate decisions despite the fact that this web-GIS tool only needs minimal knowledge of GIS to work with.
Architecting the Safety Assessment of Large-scale Systems Integration
2009-12-01
Electromagnetic Radiation to Ordnance ( HERO ) Hazards of Electromagnetic Radiation to Fuel (HERF) The main reason that this particular safety study... radiation , high voltage electric shocks and explosives safety. 1. Radiation Hazards (RADHAZ) RADHAZ describes the hazards of electromagnetic radiation ...OP3565/NAVAIR 16-1-529 [19 and 20], these hazards are segregated as follows: Hazards of Electromagnetic
ERIC Educational Resources Information Center
Ohio State Dept. of Education, Columbus. Div. of Vocational Education.
This training manual for emergency medical technicians, one of 14 modules that comprise the Emergency Victim Care textbook, covers water accidents, electrical emergencies, and hazardous materials and radiation accidents. Objectives stated for the three chapters are for the students to be able to describe: emergency care for specified water…
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
46 CFR 111.106-17 - Piping: electrical bonding.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Piping: electrical bonding. 111.106-17 Section 111.106-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations on OSVs § 111.106-17 Piping: electrical bonding. (a...
Atmospheric Electrical Modeling in Support of the NASA F-106 Storm Hazards Project
NASA Technical Reports Server (NTRS)
Helsdon, John H., Jr.
1988-01-01
A recently developed storm electrification model (SEM) is used to investigate the operating environment of the F-106 airplane during the NASA Storm Hazards Project. The model is 2-D, time dependent and uses a bulkwater microphysical parameterization scheme. Electric charges and fields are included, and the model is fully coupled dynamically, microphysically and electrically. One flight showed that a high electric field was developed at the aircraft's operating altitude (28 kft) and that a strong electric field would also be found below 20 kft; however, this low-altitude, high-field region was associated with the presence of small hail, posing a hazard to the aircraft. An operational procedure to increase the frequency of low-altitude lightning strikes was suggested. To further the understanding of lightning within the cloud environment, a parameterization of the lightning process was included in the SEM. It accounted for the initiation, propagation, termination, and charge redistribution associated with an intracloud discharge. Finally, a randomized lightning propagation scheme was developed, and the effects of cloud particles on the initiation of lightning investigated.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-16
... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility... Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial... electric utility steam generating units (EGUs) and standards of performance for fossil-fuel-fired electric...
Safety Assessment of Multi Purpose Small Payload Rack(MSPR)
NASA Astrophysics Data System (ADS)
Mizutani, Yoshinobu; Takada, Satomi; Murata, Kosei; Ozawa, Daisaku; Kobayashi, Ryoji; Nakamura, Yasuhiro
2010-09-01
We are reporting summary of preliminary safety assessment for Multi Purpose Small Payload Rack(MSPR), which is one of the micro gravity experiment facilities that are being developed for the 2nd phase JEM utilization(JEM: Japanese Experiment Module) that will be launched on H-II Transfer Vehicle(HTV) 2nd flight in 2011. MSPR is used for multi-purpose micro-g experiment providing experimental spaces and work stations. MSPR has three experimental spaces; first, there is a space called Work Volume(WV) with capacity volume of approximately 350 litters, in which multiple resources including electricity, communication, and moving image functions can be used. Within this space, installation of devices can be done by simple, prompt attachment by Velcro and pins with high degree of flexibility. Second, there is Small Experiment Area(SEA), with capacity volume of approximately 70 litters, in which electricity, communication, and moving image functions can also be used in the same way as WV. These spaces protect experiment devices and specimens from contingent loads by the crewmembers. Third, there is Work Bench with area of 0.5 square meters, on which can be used for maintenance, inspection and data operations of installed devices, etc. This bench can be stored in the rack during contingency. Chamber for Combustion Experiment(CCE) that is planned to be installed in WV is a pressure-resistant experimental container that can be used to seal hazardous materials from combustion experiments. This CCE has double sealing design in chamber itself, which resist gas leakage under normal the temperature and pressure. Electricity, communication, moving image function can be used in the same way as WV. JAXA Phase 2 Safety Review Panel(SRP) has been held in April, 2010. For safety analysis of MSPR, hazards were identified based on Fault Tree Analysis methodology and then these hazards were classified into either eight ISS standard-type hazards or eight unique-type hazards that requires special controls based on ISS common safety assessment methodology. Safety evaluation results are reported in the Safety Assessment Report(SAR) 1). Regarding structural failure, unique hazards are especially evaluated considering not only the tolerance for launch load but also load by crewmembers or orbital loads. Regarding electrical shock, electricity design up to secondary power is evaluated in unique hazard from a view point of Electrical design suitable for high voltage(32VDC or more) circuit. Regarding rupture/leakage of pressure system, hazards of fuel supply line, waste line for combustion gas, and pressure system including CCE are evaluated. Also evaluation for contamination due to hazardous gas leakage from CCE is conducted. External propagation of fire from CCE is also evaluated. In this report, we will show the overview of the result of safety assessment and future plan toward critical design phase activity.
Regional United States electric field and GIC hazard impacts (Invited)
NASA Astrophysics Data System (ADS)
Gannon, J. L.; Balch, C. C.; Trichtchenko, L.
2013-12-01
Geomagnetically Induced Currents (GICs) are primarily driven by impulsive geomagnetic disturbances created by the interaction between the Earth's magnetosphere and sharp velocity, density, and magnetic field enhancements in the solar wind. However, the magnitude of the induced electric field response at the ground level, and therefore the resulting hazard to the bulk power system, is determined not only by magnetic drivers, but also by the underlying geology. Convolution techniques are used to calculate surface electric fields beginning from the spectral characteristics of magnetic field drivers and the frequency response of the local geology. Using these techniques, we describe historical scenarios for regions across the United States, and the potential impact of large events on electric power infrastructure.
46 CFR 108.187 - Ventilation for brush type electric motors in classified spaces.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation for brush type electric motors in classified... Ventilation for brush type electric motors in classified spaces. Ventilation for brush type electric motors in... Electrical Equipment in Hazardous Locations”, except audible and visual alarms may be used if shutting down...
NASA Technical Reports Server (NTRS)
Kerslake, Thomas W.; Scheiman, David A.
2005-01-01
This paper documents testing and analyses to quantify International Space Station (ISS) Solar Array Wing (SAW) string electrical performance under highly off-nominal, low-temperature-low-intensity (LILT) operating conditions with nonsolar light sources. This work is relevant for assessing feasibility and risks associated with a Sequential Shunt Unit (SSU) remove and replace (R&R) Extravehicular Activity (EVA). During eclipse, SAW strings can be energized by moonlight, EVA suit helmet lights or video camera lights. To quantify SAW performance under these off-nominal conditions, solar cell performance testing was performed using full moon, solar simulator and Video Camera Luminaire (VCL) light sources. Test conditions included 25 to 110 C temperatures and 1- to 0.0001-Sun illumination intensities. Electrical performance data and calculated eclipse lighting intensities were combined to predict SAW current-voltage output for comparison with electrical hazard thresholds. Worst case predictions show there is no connector pin molten metal hazard but crew shock hazard limits are exceeded due to VCL illumination. Assessment uncertainties and limitations are discussed along with operational solutions to mitigate SAW electrical hazards from VCL illumination. Results from a preliminary assessment of SAW arcing are also discussed. The authors recommend further analyses once SSU, R&R, and EVA procedures are better defined.
Protect Yourself and Others from Electrical Hazards after a Disaster
... emergency medical help . Turn off the source of electricity if possible. If not, move the source away ... the person is free of the source of electricity, check the person’s breathing and pulse. If either ...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
Development of a microwave clothes dryer: Interim report 4. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, R.; Lenz, R.
1996-03-01
The objective of the project is to investigate the microwave drying of clothes and to produce data that potential manufacturers can use in developing marketable microwave dryers. This is an interim report covering activities in 1994, the fifth year of the project. During 1994, three field test dryers were completed, two residential models and one commercial subscale model. All of these dryers operated at a microwave frequency of 2,450 MHz, which is the frequency of home microwave ovens and ovens used in fastfood outlets. Consequently, magnetron tubes for these high-production items are inexpensive. The residential dryers were tested according tomore » the Department of Energy protocols and were 15% more efficient than a top-of-the-line conventional electric dryer. They were also 14% faster. Extensive testing was done to assure that the hazard-detection (sniffer) system would sense degradation of the lighter and shut down the dryer before a fire could occur. Numerous butane lighters were heated to destruction in a microwave oven to examine their failure modes. Lighters were placed in microwave dryers equipped with hazard-detection systems; these systems always detected incipient problems before any fire hazard could occur.« less
The Impact of Natural Hazards such as Turbulent Wind Gusts on the Wind Energy Conversion Process
NASA Astrophysics Data System (ADS)
Wächter, M.; Hölling, M.; Milan, P.; Morales, A.; Peinke, J.
2012-12-01
Wind turbines operate in the atmospheric boundary layer, where they are exposed to wind gusts and other types of natural hazards. As the response time of wind turbines is typically in the range of seconds, they are affected by the small scale intermittent properties of the turbulent wind. We show evidence that basic features which are known for small-scale homogeneous isotropic turbulence, and in particular the well-known intermittency problem, have an important impact on the wind energy conversion process. Intermittent statistics include high probabilities of extreme events which can be related to wind gusts and other types of natural hazards. As a summarizing result we find that atmospheric turbulence imposes its intermittent features on the complete wind energy conversion process. Intermittent turbulence features are not only present in atmospheric wind, but are also dominant in the loads on the turbine, i.e. rotor torque and thrust, and in the electrical power output signal. We conclude that profound knowledge of turbulent statistics and the application of suitable numerical as well as experimental methods are necessary to grasp these unique features and quantify their effects on all stages of wind energy conversion.
Electrical Safety: Safety and Health for Electrical Trades. Student Manual.
ERIC Educational Resources Information Center
Fowler, Thaddeus W.; Miles, Karen K.
This document is designed to teach learners in secondary and postsecondary electrical trades courses to recognize, evaluate, and control hazards associated with electrical work, The manual's eight sections each include some or all of the following components: instructional text; definitions; case studies illustrating key safety considerations;…
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) You must classify all areas according to API RP 500, Recommended Practice for Classification of... Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical... and hazards of electrical equipment. (c) You must install all electrical systems according to API RP...
30 CFR 46.5 - New miner training.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and loose or... aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition training specific...
30 CFR 46.5 - New miner training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and loose or... aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition training specific...
30 CFR 19.8 - Protection against bodily hazard.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection against bodily hazard. 19.8 Section 19.8 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.8 Protection against bodily hazard. This...
A Study of Aircraft Fire Hazards Related to Natural Electrical Phenomena
NASA Technical Reports Server (NTRS)
Kester, Frank L.; Gerstein, Melvin; Plumer, J. A.
1960-01-01
The problems of natural electrical phenomena as a fire hazard to aircraft are evaluated. Assessment of the hazard is made over the range of low level electrical discharges, such as static sparks, to high level discharges, such as lightning strikes to aircraft. In addition, some fundamental work is presented on the problem of flame propagation in aircraft fuel vent systems. This study consists of a laboratory investigation in five parts: (1) a study of the ignition energies and flame propagation rates of kerosene-air and JP-6-air foams, (2) a study of the rate of flame propagation of n-heptane, n-octane, n-nonane, and n-decane in aircraft vent ducts, (3) a study of the damage to aluminum, titanium, and stainless steel aircraft skin materials by lightning strikes, (4) a study of fuel ignition by lightning strikes to aircraft skins, and (5) a study of lightning induced flame propagation in an aircraft vent system.
Wet snow hazard for power lines: a forecast and alert system applied in Italy
NASA Astrophysics Data System (ADS)
Bonelli, P.; Lacavalla, M.; Marcacci, P.; Mariani, G.; Stella, G.
2011-09-01
Wet snow icing accretion on power lines is a real problem in Italy, causing failures on high and medium voltage power supplies during the cold season. The phenomenon is a process in which many large and local scale variables contribute in a complex way and not completely understood. A numerical weather forecast can be used to select areas where wet snow accretion has an high probability of occurring, but a specific accretion model must also be used to estimate the load of an ice sleeve and its hazard. All the information must be carefully selected and shown to the electric grid operator in order to warn him promptly. The authors describe a prototype of forecast and alert system, WOLF (Wet snow Overload aLert and Forecast), developed and applied in Italy. The prototype elaborates the output of a numerical weather prediction model, as temperature, precipitation, wind intensity and direction, to determine the areas of potential risk for the power lines. Then an accretion model computes the ice sleeves' load for different conductor diameters. The highest values are selected and displayed on a WEB-GIS application principally devoted to the electric operator, but also to more expert users. Some experimental field campaigns have been conducted to better parameterize the accretion model. Comparisons between real accidents and forecasted icing conditions are presented and discussed.
NASA Technical Reports Server (NTRS)
Farrell, W. M.; Desch, M. D.; Marshall, J. R.; Delory, G. T.; Kolecki, J. C.; Hillard, G. B.; Kaiser, M. L.; Haberle, R. M.; Zent, A. P.; Luhmann, J. G.
2000-01-01
In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.
30 CFR 46.6 - Newly hired experienced miner training.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Instruction on the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and... health and safety aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition...
30 CFR 46.6 - Newly hired experienced miner training.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Instruction on the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and... health and safety aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition...
46 CFR 111.105-17 - Wiring methods for hazardous locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Wiring methods for hazardous locations. 111.105-17... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-17 Wiring methods for... made with dust-tight cable entrance seals approved for the installation. [CGD 94-108, 61 FR 28284, June...
NASA Astrophysics Data System (ADS)
Brinovar, Iztok; Srpčič, Gregor; Seme, Sebastijan; Štumberger, Bojan; Hadžiselimović, Miralem
2017-07-01
This article deals with the classification of explosion-proof protected induction motors, which are used in hazardous areas, into adequate temperature and efficiency class. Hazardous areas are defined as locations with a potentially explosive atmosphere where explosion may occur due to present of flammable gasses, liquids or combustible dusts (industrial plants, mines, etc.). Electric motors and electrical equipment used in such locations must be specially designed and tested to prevent electrical initiation of explosion due to high surface temperature and arcing contacts. This article presents the basic tests of three-phase explosion-proof protected induction motor with special emphasis on the measuring system and temperature rise test. All the measurements were performed with high-accuracy instrumentation and accessory equipment and carried out at the Institute of energy technology in the Electric machines and drives laboratory and Applied electrical engineering laboratory.
Chemical hazards associated with treatment of waste electrical and electronic equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsydenova, Oyuna; Bengtsson, Magnus, E-mail: bengtsson@iges.or.jp
2011-01-15
This review paper summarizes the existing knowledge on the chemical hazards associated with recycling and other end-of-life treatment options of waste electrical and electronic equipment (e-waste). The hazards arise from the presence of heavy metals (e.g., mercury, cadmium, lead, etc.), flame retardants (e.g., pentabromophenol, polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol-A (TBBPA), etc.) and other potentially harmful substances in e-waste. If improperly managed, the substances may pose significant human and environmental health risks. The review describes the potentially hazardous content of e-waste, examines the existing e-waste management practices and presents scientific data on human exposure to chemicals, workplace and environmental pollution associatedmore » with the three major e-waste management options, i.e., recycling, incineration and landfilling. The existing e-waste management practices and associated hazards are reviewed separately for developed and developing countries. Finally, based on this review, the paper identifies gaps in the existing knowledge and makes some recommendations for future research.« less
BCI federal legislative & regulatory update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-02-01
Several updates on recent government actions that affect the battery industry are outlined. The National Highway Traffic Safety Administration is requesting public comments on how to regulate electric vehicles (EV) with respect to battery electrolyte spillage and electric shock hazard during crashes or rollovers, as well as during repair or maintenance. The Environmental Protection Agency (EPA) was mentioned in two actions: the monitoring rule regarding major sources of air pollution and the reccomendation of reasearch concerning hazardous air pollutants from small stationary sources. OSHA will develop a new standards planning process to ensure that the agency`s limited resources are usedmore » appropriately. This includes a list of fifty workplace hazards or issues that would warrant OSHA action.« less
40 CFR 264.120 - Certification of completion of post-closure care.
Code of Federal Regulations, 2010 CFR
2010-07-01
... certification that the post-closure care period for the hazardous waste disposal unit was performed in...) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... later than 60 days after completion of the established post-closure care period for each hazardous waste...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
Evaluation of Equipment Vulnerability and Potential Shock Hazards. [carbon fibers
NASA Technical Reports Server (NTRS)
Taback, I.
1980-01-01
The vulnerability of electric equipment to carbon fibers released from aircraft accidents is investigated and the parameters affecting vulnerability are discussed. The shock hazard for a hypothetical set of accidents is computed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-07-01
This Necessary and Sufficient (N and S) set of standards is for Other Industrial, Radiological, and Non-Radiological Hazard Facilities at Oak Ridge National Laboratory (ORNL). These facility classifications are based on a laboratory-wide approach to classify facilities by hazard category. An analysis of the hazards associated with the facilities at ORNL was conducted in 1993. To identify standards appropriate for these Other Industrial, Radiological, and Non-Radiological Hazard Facilities, the activities conducted in these facilities were assessed, and the hazards associated with the activities were identified. A preliminary hazards list was distributed to all ORNL organizations. The hazards identified in priormore » hazard analyses are contained in the list, and a category of other was provided in each general hazard area. A workshop to assist organizations in properly completing the list was held. Completed hazard screening lists were compiled for each ORNL division, and a master list was compiled for all Other Industrial, Radiological Hazard, and Non-Radiological facilities and activities. The master list was compared against the results of prior hazard analyses by research and development and environment, safety, and health personnel to ensure completeness. This list, which served as a basis for identifying applicable environment, safety, and health standards, appears in Appendix A.« less
2013-07-18
are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental
... Use flashlights or lanterns instead. Never use an electric generator or a gas or charcoal grill indoors. ... heater. Make sure that the cord of an electric space heater is not a tripping hazard but ...
46 CFR 108.177 - Electrical equipment in classified locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Electrical equipment in classified locations. 108.177 Section 108.177 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE... equipment in classified locations. Electrical equipment and devices installed in spaces made non-hazardous...
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Systems; (3) Electrical system information including a plan of each platform deck, outlining all hazardous... Electrical Installations at Petroleum Facilities Classified as Class I, Division 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... individual electrical installation in a hazardous location must comply specifically with Articles 500-505 of...
Seismic Retrofit for Electric Power Systems
Romero, Natalia; Nozick, Linda K.; Dobson, Ian; ...
2015-05-01
Our paper develops a two-stage stochastic program and solution procedure to optimize the selection of seismic retrofit strategies to increase the resilience of electric power systems against earthquake hazards. The model explicitly considers the range of earthquake events that are possible and, for each, an approximation of the distribution of damage experienced. Furthermore, this is important because electric power systems are spatially distributed and so their performance is driven by the distribution of component damage. We also test this solution procedure against the nonlinear integer solver in LINGO 13 and apply the formulation and solution strategy to the Eastern Interconnection,more » where seismic hazard stems from the New Madrid seismic zone.« less
Solar Photovoltaic DC Systems: Basics and Safety: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNutt, Peter F; Sekulic, William R; Dreifuerst, Gary
Solar Photovoltaic (PV) systems are common and growing with 42.4 GW installed capacity in U.S. (almost 15 GW added in 2016). This paper will help electrical workers, and emergency responders understand the basic operating principles and hazards of PV DC arrays. We briefly discuss the following aspects of solar photovoltaic (PV) DC systems: the effects of solar radiation and temperature on output power; PV module testing standards; common system configurations; a simple PV array sizing example; NEC guidelines and other safety features; DC array commissioning, periodic maintenance and testing; arc-flash hazard potential; how electrical workers and emergency responders can andmore » do work safely around PV arrays; do moonlight and artificial lighting pose a real danger; typical safe operating procedures; and other potential DC-system hazards to be aware of. We also present some statistics on PV DC array electrical incidents and injuries. Safe PV array operation is possible with a good understanding of PV DC arrays basics and having good safe operating procedures in place.« less
Personnel Safety on Electrified Railroads
DOT National Transportation Integrated Search
1980-06-01
Potential electrical hazards to fire, police, and rescue personnel responding to emergencies on electrified railways are examined. Data on descriptions of electrical facilities, types of accidents and danger to emergency personnel, and reviews of ope...
Recommended safety guides for industrial laboratories and shops
NASA Technical Reports Server (NTRS)
Allison, W. W.
1971-01-01
Booklet provides references to 29 publications providing information on hazard control and approved safety practices. Areas include pressurized gas and vacuum systems. Guidelines are presented for safeguarding facilities where machinery, equipment, electrical devices, or hazardous chemicals are used.
Safety in the Automated Office.
ERIC Educational Resources Information Center
Graves, Pat R.; Greathouse, Lillian R.
1990-01-01
Office automation has introduced new hazards to the workplace: electrical hazards related to computer wiring, musculoskeletal problems resulting from use of computer terminals and design of work stations, and environmental concerns related to ventilation, noise levels, and office machine chemicals. (SK)
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2013 CFR
2013-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2012 CFR
2012-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2014 CFR
2014-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
Yang, Xiaobao; Huan, Mei; Abdel-Aty, Mohamed; Peng, Yichuan; Gao, Ziyou
2015-01-01
This paper presents a hazard-based duration approach to investigate riders' waiting times, violation hazards, associated risk factors, and their differences between cyclists and electric bike riders at signalized intersections. A total of 2322 two-wheeled riders approaching the intersections during red light periods were observed in Beijing, China. The data were classified into censored and uncensored data to distinguish between safe crossing and red-light running behavior. The results indicated that the red-light crossing behavior of most riders was dependent on waiting time. They were inclined to terminate waiting behavior and run against the traffic light with the increase of waiting duration. Over half of the observed riders cannot endure 49s or longer. 25% of the riders can endure 97s or longer. Rider type, gender, waiting position, conformity tendency and crossing traffic volume were identified to have significant effects on riders' waiting times and violation hazards. Electric bike riders were found to be more sensitive to the external risk factors such as other riders' crossing behavior and crossing traffic volume than cyclists. Moreover, unobserved heterogeneity was examined in the proposed models. The finding of this paper can explain when and why cyclists and electric bike riders run against the red light at intersections. The results of this paper are useful for traffic design and management agencies to implement strategies to enhance the safety of riders. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bernstad, Anna; la Cour Jansen, Jes; Aspegren, Henrik
2011-03-01
Through an agreement with EEE producers, Swedish municipalities are responsible for collection of hazardous waste and waste electrical and electronic equipment (WEEE). In most Swedish municipalities, collection of these waste fractions is concentrated to waste recycling centres where households can source-separate and deposit hazardous waste and WEEE free of charge. However, the centres are often located on the outskirts of city centres and cars are needed in order to use the facilities in most cases. A full-scale experiment was performed in a residential area in southern Sweden to evaluate effects of a system for property-close source separation of hazardous waste and WEEE. After the system was introduced, results show a clear reduction in the amount of hazardous waste and WEEE disposed of incorrectly amongst residual waste or dry recyclables. The systems resulted in a source separation ratio of 70 wt% for hazardous waste and 76 wt% in the case of WEEE. Results show that households in the study area were willing to increase source separation of hazardous waste and WEEE when accessibility was improved and that this and similar collection systems can play an important role in building up increasingly sustainable solid waste management systems. Copyright © 2010 Elsevier Ltd. All rights reserved.
Odendaal, Willem; van Niekerk, Ashley; Jordaan, Esme; Seedat, Mohamed
2009-01-01
The continued high mortality and morbidity rates for unintentional childhood injuries remain a public health concern. This article reports on the influence of a home visitation programme (HVP) on household hazards associated with unintentional childhood injuries in a South African low-income setting. A randomised controlled trial (n=211 households) was conducted in a South African informal settlement. Community members were recruited and trained as paraprofessional visitors. Four intervention visits were conducted over 3 months, focusing on child development, and the prevention of burn, poison, and fall injuries. The HVP, a multi-component intervention, included educational inputs, provision of safety devices, and an implicit enforcement strategy. The intervention effect (IE) was measured with a standardised risk assessment index that compared post-intervention scores for intervention and control households. A significant reduction was observed in the hazards associated with electrical and paraffin appliances, as well as in hazards related to poisoning. Non-significant changes were observed for burn safety household practices and fall injury hazards. This study confirmed that a multi-component HVP effectively reduced household hazards associated with electrical and paraffin appliances and poisoning among children in a low-income South African setting.
78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-19
... Coal- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... before March 1, 2005, means a 24-hour period during which fossil fuel is combusted in a steam-generating...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
...-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... copy form. The hearing schedules, including lists of speakers, will be posted on EPA's Web Sites http...
NASA Technical Reports Server (NTRS)
1961-01-01
The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.
Brandon M. Collins; Heather A. Kramer; Kurt Menning; Colin Dillingham; David Saah; Peter A. Stine; Scott L. Stephens
2013-01-01
We built on previous work by performing a more in-depth examination of a completed landscape fuel treatment network. Our specific objectives were: (1) model hazardous fire potential with and without the treatment network, (2) project hazardous fire potential over several decades to assess fuel treatment network longevity, and (3) assess fuel treatment effectiveness and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
...- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel... Performance for Fossil-Fuel- Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial...
SUPERFUND TREATABILITY CLEARINGHOUSE ...
This newsletter reports on the Huber Technology Groups (HTG) high temperature advanced hazardous waste treatment technology capable of very high destruction and removal efficiencies of various hazardous wastes. This newsletter addresses the destruction of PCBs in an EPA certification test of the HTG Advanced Electric Reactor. provide information
Seismic Landslide Hazard for the Cities of Oakland and Piedmont, California
Miles, Scott B.; Keefer, David K.
2001-01-01
This map describes the possible hazard from earthquake-induced landslides for the cities of Oakland and Piedmont, CA. The hazard depicted by this map was modeled for a scenario corresponding to an M=7.1 earthquake on the Hayward, CA fault. This scenario magnitude is associated with complete rupture of the northern and southern segments of the Hayward fault, an event that has an estimated return period of about 500 years. The modeled hazard also corresponds to completely saturated ground-water conditions resulting from an extreme storm event or series of storm events. This combination of earthquake and ground-water scenarios represents a particularly severe state of hazard for earthquake-induced landslides. For dry ground-water conditions, overall hazard will be less, while relative patterns of hazard are likely to change.
NASA Astrophysics Data System (ADS)
Love, J. J.
2016-12-01
Magnetic-storm induction of geoelectric fields in the Earth's electrically conducting crust, lithosphere, mantle, and ocean can interfere with the operations of electric-power grid systems. The future occurrence of an extremely intense magnetic storm might even result in continental-scale failure of electric-power distribution. Such an event would entail significant deleterious consequence for the economy and international security. Building on a project established by the President's National Science and Technology Council and the Office of Science and Technology Policy for assessing space-weather induction hazards, we develop a series of geoelectric hazard maps. These are constructed using an empirical parameterization of induction: local estimates of Earth-surface impedance, obtained from EarthScope and USGS magnetotelluric survey data, are convolved with latitude-dependent statistical maps of extreme-value geomagnetic activity, obtained from decades magnetic observatory data. Geoelectric hazard maps are constructed for both north-south and east-west geomagnetic variation, and for both 240-s and 1200-s sinusoidal variation -- periods of interest to the power-grid industry. The maps cover about half of the continental United States. They depict the threshold level that geoelectric amplitude can be expected to exceed, on average, once per century at discrete geographic sites in response to extreme-intensity geomagnetic activity. Of the regions where magnetotelluric data are available, the greatest induction hazards are found in Minnesota, Wisconsin, and Iowa - this being the result of both high-latitude geomagntic activity and complex subsurface conductivity structure. At some sites in the continental United States, once-per-century geoelectric amplitudes can exceed the 1.7 V/km realized in Quebec during the March 1989 storm. This work highlights the importance of geophysical surveys and ground-level monitoring data for assessing space-weather induction hazards.
30 CFR 77.1304 - Blasting agents; special provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... connection with pneumatic loading machines shall be of the semiconductive type, having a total resistance low... electric currents to a safe level. Wire-countered hose shall not be used because of the potential hazard from stray electric currents. ...
30 CFR 77.1304 - Blasting agents; special provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... connection with pneumatic loading machines shall be of the semiconductive type, having a total resistance low... electric currents to a safe level. Wire-countered hose shall not be used because of the potential hazard from stray electric currents. ...
Hazardous Waste Cleanup: General Electric - Auburn Plant in Auburn, New York
GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc.,
HAZARDOUS WASTE DECONTAMINATION WITH PLASMA REACTORS
The use of electrical energy in the form of plasma has been considered as a potentially efficient means of decontaminating hazardous waste, although to date only a few attempts have been made to do so. There are a number of relative advantages and some potential disadvantages to...
This newsletter reports on the Huber Technology Groups (HTG) high temperature advanced hazardous waste treatment technology capable of very high destruction and removal efficiencies of various hazardous wastes. This newsletter addresses the destruction of PCBs in an EPA certifi...
Determination of heavy metals and halogens in plastics from electric and electronic waste.
Dimitrakakis, Emmanouil; Janz, Alexander; Bilitewski, Bernd; Gidarakos, Evangelos
2009-10-01
The presence of hazardous substances and preparations in small waste electrical and electronic equipment (sWEEE) found in the residual household waste stream of the city of Dresden, Germany has been investigated. The content of sWEEE plastics in heavy metals and halogens is determined using handheld X-ray fluorescence analysis (HXRF), elemental analysis by means of atomic absorption spectrometry (AAS) and ion exchange chromatography (IEC). Mean value of results for heavy metals in samples (n=51) by AAS are 17.4 mg/kg for Pb, 5.7 mg/kg for Cd, 8.4 mg/kg for Cr. The mass fraction of an additive as shown by HXRF (n=161) can vary over a wide range. Precise deductions as regards sWEEE plastics content in hazardous substances and preparations cannot be made. Additional research would be expedient regarding the influence of hazardous substances to recycling processes, in particular regarding the contamination of clean fractions in the exit streams of a WEEE treatment plant. Suitable standards for calibrating HXRF for use on EEE plastics or complex electr(on)ic components do not exist and should be developed.
Airborne EM survey in volcanoes : Application to a volcanic hazards assessment
NASA Astrophysics Data System (ADS)
Mogi, T.
2010-12-01
Airborne electromagnetics (AEM) is a useful tool for investigating subsurface structures of volcanoes because it can survey large areas involving inaccessible areas. Disadvantages include lower accuracy and limited depth of investigation. AEM has been widely used in mineral exploration in frontier areas, and have been applying to engineering and environmental fields, particularly in studies involving active volcanoes. AEM systems typically comprise a transmitter and a receiver on an aircraft or in a towed bird, and although effective for surveying large areas, their penetration depth is limited because the distance between the transmitter and receiver is small and higher-frequency signals are used. To explore deeper structures using AEM, a semi-airborne system called GRounded Electrical source Airborne Transient ElectroMagnetics (GREATEM) has been developed. The system uses a grounded-electrical-dipole as the transmitter and generates horizontal electric fields. The GREATEM technology, first proposed by Mogi et al. (1998), has recently been improved and used in practical surveys (Mogi et al., 2009). The GREATEM survey system was developed to increase the depth of investigation possible using AEM. The method was tested in some volcanoes at 2004-2005. Here I will talk about some results of typical AEM surveys and GREATEM surveys in some volcanoes in Japan to mitigate hazards associated with volcano eruption. Geologic hazards caused by volcanic eruptions can be mitigated by a combination of prediction, preparedness and land-use control. Risk management depends on the identification of hazard zones and forecasting of eruptions. Hazard zoning involves the mapping of deposits which have formed during particular phases of volcanic activity and their extrapolation to identify the area which would be likely to suffer a similar hazard at some future time. The mapping is usually performed by surface geological surveys of volcanic deposits. Resistivity mapping by AEM is useful tool to identify each volcanic deposit on the surface and at shallower depth as well. This suggests that more efficient hazard map involving subsurface information can be supplied by AEM resistivity mapping.
30 CFR 57.4600 - Extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... electrically conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...
Hazardous Waste Cleanup: Consolidated Edison Company of NY - Indian Point 2 in Buchanan, New York
Indian Point Unit 2 is a nuclear-powered electricity generating plant located in the village of Buchanan, Westchester County, New York. The facility generates and stores ignitable and mixed hazardous and radioactive waste on site. On February 28, 1997, New
Favorable Decision Upholding Radioactive/Hazardous Mixed Waste Storage Civil Enforcement Policy
This page contains a copy of the U.S. Court of Appeals (District of Columbia Circuit) decision in Edison Electric Institute, et al. v. EPA, No. 91-1586, which upheld the EPA's August 29, 1991, radioactive/hazardous 'mixed waste' storage civil enforcement policy
NASA Technical Reports Server (NTRS)
Hwu, Shian U.; Kelley, James S.; Panneton, Robert B.; Arndt, G. Dickey
1995-01-01
In order to estimate the RF radiation hazards to astronauts and electronics equipment due to various Space Station transmitters, the electric fields around the various Space Station antennas are computed using the rigorous Computational Electromagnetics (CEM) techniques. The Method of Moments (MoM) was applied to the UHF and S-band low gain antennas. The Aperture Integration (AI) method and the Geometrical Theory of Diffraction (GTD) method were used to compute the electric field intensities for the S- and Ku-band high gain antennas. As a result of this study, The regions in which the electric fields exceed the specified exposure levels for the Extravehicular Mobility Unit (EMU) electronics equipment and Extravehicular Activity (EVA) astronaut are identified for various Space Station transmitters.
Virtual reality simulation for construction safety promotion.
Zhao, Dong; Lucas, Jason
2015-01-01
Safety is a critical issue for the construction industry. Literature argues that human error contributes to more than half of occupational incidents and could be directly impacted by effective training programs. This paper reviews the current safety training status in the US construction industry. Results from the review evidence the gap between the status and industry expectation on safety. To narrow this gap, this paper demonstrates the development and utilisation of a training program that is based on virtual reality (VR) simulation. The VR-based safety training program can offer a safe working environment where users can effectively rehearse tasks with electrical hazards and ultimately promote their abilities for electrical hazard cognition and intervention. Its visualisation and simulation can also remove the training barriers caused by electricity's features of invisibility and dangerousness.
Hazardous waste: cleanup and prevention
Vandas, Stephen; Cronin, Nancy L.; Farrar, Frank; Serrano, Guillermo Eliezer Ávila; Yajimovich, Oscar Efraín González; Muñoz, Aurora R.; Rivera, María del C.
1996-01-01
Our lifestyles are supported by complex Industrial activities that produce many different chemicals and chemical wastes. The Industries that produce our clothing, cars, medicines, paper, food, fuels, steel, plastics, and electric components use and discard thousands of chemicals every year. At home we may use lawn chemicals, solvents, disinfectants, cleaners, and auto products to Improve our quality of life. A chemical that presents a threat or unreasonable risk to people or the environment Is a hazardous material. When a hazardous material can no longer be used, It becomes a hazardous waste. Hazardous wastes come from a variety of sources, from both present and past activities. Impacts to human health and the environment can result from Improper handling and disposal of hazardous waste.
NASA Astrophysics Data System (ADS)
Boron, Sergiusz
2017-06-01
Operational safety of electrical machines and equipment depends, inter alia, on the hazards resulting from their use and on the scope of applied protective measures. The use of insufficient protection against existing hazards leads to reduced operational safety, particularly under fault conditions. On the other hand, excessive (in relation to existing hazards) level of protection may compromise the reliability of power supply. This paper analyses the explosion hazard created by earth faults in longwall power supply systems and evaluates existing protection equipment from the viewpoint of its protective performance, particularly in the context of explosion hazards, and also assesses its effect on the reliability of power supply.
Improved high modulus carbon fibers. [elimination of hazards due to electrical properties
NASA Technical Reports Server (NTRS)
Ansell, G. S.; Chen, S. H.; Diffendorf, R. J.; Kim, C. M.; Lemaistre, C. W.; Lyman, C. E.; Shen, T. H.; Wang, J. J. H.
1979-01-01
Carbon fibers which are electrically insulating but still maintain the mechanical properties of the original carbon fibers were investigated. Three approaches were taken to increase the electrical resistance of carbon fibers: (1) boron nitride (BN) coatings; (2) doping of carbon fibers to alter their electrical properties; and (3) low temperature final heat treatment. The structure of carbon fibers and its effect upon properties was also studied. Results are presented.
Initiating Event Analysis of a Lithium Fluoride Thorium Reactor
NASA Astrophysics Data System (ADS)
Geraci, Nicholas Charles
The primary purpose of this study is to perform an Initiating Event Analysis for a Lithium Fluoride Thorium Reactor (LFTR) as the first step of a Probabilistic Safety Assessment (PSA). The major objective of the research is to compile a list of key initiating events capable of resulting in failure of safety systems and release of radioactive material from the LFTR. Due to the complex interactions between engineering design, component reliability and human reliability, probabilistic safety assessments are most useful when the scope is limited to a single reactor plant. Thus, this thesis will study the LFTR design proposed by Flibe Energy. An October 2015 Electric Power Research Institute report on the Flibe Energy LFTR asked "what-if?" questions of subject matter experts and compiled a list of key hazards with the most significant consequences to the safety or integrity of the LFTR. The potential exists for unforeseen hazards to pose additional risk for the LFTR, but the scope of this thesis is limited to evaluation of those key hazards already identified by Flibe Energy. These key hazards are the starting point for the Initiating Event Analysis performed in this thesis. Engineering evaluation and technical study of the plant using a literature review and comparison to reference technology revealed four hazards with high potential to cause reactor core damage. To determine the initiating events resulting in realization of these four hazards, reference was made to previous PSAs and existing NRC and EPRI initiating event lists. Finally, fault tree and event tree analyses were conducted, completing the logical classification of initiating events. Results are qualitative as opposed to quantitative due to the early stages of system design descriptions and lack of operating experience or data for the LFTR. In summary, this thesis analyzes initiating events using previous research and inductive and deductive reasoning through traditional risk management techniques to arrive at a list of key initiating events that can be used to address vulnerabilities during the design phases of LFTR development.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
.... South Carolina Electric & Gas Company, Case No. 2-11-cv-1110-CWH (D. S. Car. May 9, 2011). The proposed...'') against South Carolina Electric & Gas Company (``SCE&G''). The claims arise from the release of hazardous..., Washington, DC 20044-7611, and should refer to United States et al. v. South Carolina Electric & Gas Company...
Hazardous Waste Cleanup: General Electric – Main Plant Site in Schenectady, New York
GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc., ac
Environmental Cost of Electric Power, A Scientists' Institute for Public Information Workbook.
ERIC Educational Resources Information Center
Abrahamson, Dean E.
Analyzed are the environmental and health hazards associated with different forms of power production: nuclear power plants, fossil fuel plants, and hydroelectric plants. Data are given relating to chemical pollution, thermal pollution, radioactive hazards and geological and geographical effects. Problems of setting standards, and criteria which…
Risk is the combination of hazard and exposure. Risk characterization at UST release sites has traditionally emphasized hazard (presence of residual fuel) with little attention to exposure. Exposure characterization often limited to a one-dimensional model such as the RBCA equa...
29 CFR 1926.407 - Hazardous (classified) locations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Electrical Code, lists or defines hazardous gases, vapors, and dusts by “Groups” characterized by their... the class, group, and operating temperature or temperature range, based on operation in a 40-degree C... be marked to indicate the group. (C) Fixed general-purpose equipment in Class I locations, other than...
29 CFR 1926.407 - Hazardous (classified) locations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Electrical Code, lists or defines hazardous gases, vapors, and dusts by “Groups” characterized by their... the class, group, and operating temperature or temperature range, based on operation in a 40-degree C... be marked to indicate the group. (C) Fixed general-purpose equipment in Class I locations, other than...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
Approach to the assessment of the hazard. [fire released carbon fiber electrical effects
NASA Technical Reports Server (NTRS)
Huston, R. J.
1980-01-01
An overview of the carbon fiber hazard assessment is presented. The potential risk to the civil sector associated with the accidental release of carbon fibers from aircraft having composite structures was assessed along with the need for protection of civil aircraft from carbon fibers.
Progress in NTHMP Hazard Assessment
Gonzalez, F.I.; Titov, V.V.; Mofjeld, H.O.; Venturato, A.J.; Simmons, R.S.; Hansen, R.; Combellick, Rodney; Eisner, R.K.; Hoirup, D.F.; Yanagi, B.S.; Yong, S.; Darienzo, M.; Priest, G.R.; Crawford, G.L.; Walsh, T.J.
2005-01-01
The Hazard Assessment component of the U.S. National Tsunami Hazard Mitigation Program has completed 22 modeling efforts covering 113 coastal communities with an estimated population of 1.2 million residents that are at risk. Twenty-three evacuation maps have also been completed. Important improvements in organizational structure have been made with the addition of two State geotechnical agency representatives to Steering Group membership, and progress has been made on other improvements suggested by program reviewers. ?? Springer 2005.
NASA Astrophysics Data System (ADS)
Bateman, M.; Mach, D.; Lewis, S.; Dye, J.; Defer, E.; Grainger, C.; Willis, P.; Christian, H.; Merceret, F.
2003-12-01
Airborne measurements of electric fields and particle microphysics were made during a field program at NASA's Kennedy Space Center. The aircraft, a Cessna Citation II jet operated by the University of North Dakota, carried six rotating-vane style electric field mills, several microphysics instruments, and thermodynamic instruments. In addition to the aircraft measurements, we also have data from both the Eastern Test Range WSR-74C (Patrick AFB) and the U.S. National Weather Service WSR-88D radars (primarily Melbourne, FL). One specific goal of this program was to try to develop a radar-based rule for estimating the hazard that an in-cloud electric field would present to a vehicle launched into the cloud. Based on past experience, and our desire to quantify the mixed-phase region of the cloud in question, we have assessed several algorithms for integrating radar reflectivity data in and above the mixed-phase region as a proxy for electric field. A successful radar proxy is one that can accurately predict the presence or absence of significant electric fields. We have compared various proxies with the measured in-cloud electric field strength in an attempt to develop a radar rule for assessing launch hazard. Assessment of the best proxy is presented.
Hosseini, Monireh; Monazzam, Mohammad Reza; Farhang Matin, Laleh; Khosroabadi, Hossein
2015-05-01
Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 μT recorded from boiler substation, while the minimum magnetic flux density of 0.02 μT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.
An overview of natural hazard impacts to railways and urban transportation systems
NASA Astrophysics Data System (ADS)
Bíl, Michal; Nezval, Vojtěch; Bílová, Martina; Andrášik, Richard; Kubeček, Jan
2017-04-01
We present an overview and two case studies of natural hazard impacts on rail transportation systems in the Czech Republic. Flooding, landsliding, heavy snowfall, windstorms and glaze (black ice) are the most common natural processes which occur in this region. Whereas flooding and landsliding usually cause direct damage to the transportation infrastructure, other hazards predominantly cause indirect losses. Railway and urban tramline networks are almost fully dependent on electricity which is provided by a system of overhead lines (electric lines above the tracks). These lines are extremely susceptible to formation of glaze which blocks conduction of electric current. A December 2014 glaze event caused significant indirect losses in the largest Czech cities and railways due to the above-mentioned process. Details of this event will be provided during the presentation. Windstorms usually cause tree falls which can affect overhead lines and physically block railway tracks. Approximately 30 % of the Czech railway network is closer than 50 m from the nearest forest. This presents significant potential for transport interruption due to falling trees. Complicated legal relations among the owners of the plots of land along railways, the environment (full-grown trees and related habitat), and the railway administrator are behind many traffic interruptions due to falling trees. We have registered 2040 tree falls between 2012 and 2015 on the railway network. A model of the fallen tree hazard was created for the entire Czech railway network. Both above-mentioned case studies provide illustrative examples of the increased fragility of the modern transportation systems which fully rely on electricity. Natural processes with a low destructive power are thereby able to cause network wide service cut-offs.
46 CFR 111.105-1 - Applicability; definition.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Applicability; definition. 111.105-1 Section 111.105-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-1 Applicability; definition. This subpart applies to...
46 CFR 111.105-1 - Applicability; definition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Applicability; definition. 111.105-1 Section 111.105-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-1 Applicability; definition. This subpart applies to...
CONTROL OF MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC UTILITY BOILERS: INTERIM REPORT
The report provides additional information on mercury (Hg) emissions control following the release of "Study of Hazardous Air Pollutant Emissions from Electric Utility Steam Generating Units--Final Report to Congress" in February 1998. Chapters 1-3 describe EPA's December 2000 de...
Tunable molten oxide pool assisted plasma-melter vitrification systems
Titus, Charles H.; Cohn, Daniel R.; Surma, Jeffrey E.
1998-01-01
The present invention provides tunable waste conversion systems and apparatus which have the advantage of highly robust operation and which provide complete or substantially complete conversion of a wide range of waste streams into useful gas and a stable, nonleachable solid product at a single location with greatly reduced air pollution to meet air quality standards. The systems provide the capability for highly efficient conversion of waste into high quality combustible gas and for high efficiency conversion of the gas into electricity by utilizing a high efficiency gas turbine or an internal combustion engine. The solid product can be suitable for various commercial applications. Alternatively, the solid product stream, which is a safe, stable material, may be disposed of without special considerations as hazardous material. In the preferred embodiment, the arc plasma furnace and joule heated melter are formed as a fully integrated unit with a common melt pool having circuit arrangements for the simultaneous independently controllable operation of both the arc plasma and the joule heated portions of the unit without interference with one another. The preferred configuration of this embodiment of the invention utilizes two arc plasma electrodes with an elongated chamber for the molten pool such that the molten pool is capable of providing conducting paths between electrodes. The apparatus may additionally be employed with reduced use or without further use of the gases generated by the conversion process. The apparatus may be employed as a net energy or net electricity producing unit where use of an auxiliary fuel provides the required level of electricity production. Methods and apparatus for converting metals, non-glass forming waste streams and low-ash producing inorganics into a useful gas are also provided. The methods and apparatus for such conversion include the use of a molten oxide pool having predetermined electrical, thermal and physical characteristics capable of maintaining optimal joule heating and glass forming properties during the conversion process.
Are perceived neighborhood hazards a barrier to physical activity in children?
Romero, A J; Robinson, T N; Kraemer, H C; Erickson, S J; Haydel, K F; Mendoza, F; Killen, J D
2001-10-01
We hypothesized that children's perceptions of more neighborhood hazards would be associated with less physical activity, less aerobic fitness, and a higher body mass index. To examine the association between a hazardous neighborhood context and physical activity in children. Fourth-grade students (n = 796) of diverse ethnic and economic backgrounds completed measures of neighborhood hazards, self-reported physical activity, physical fitness, height, and weight. Parents (n = 518) completed telephone interviews and provided data on their education level and occupation. As expected, children from families of lower socioeconomic status perceived significantly more neighborhood hazards. Contrary to our hypothesis, the perception of more hazards was significantly associated with more reported physical activity. This finding was not explained by school heterogeneity, alteration of the hazards measure, or differences in socioeconomic status. To further examine the relationship between neighborhood hazards and physical activity, we suggest that future studies include assessments of sedentary behavior, parental fear of violence, parental regulation of children's leisure activities, and cost and quality of available play areas and organized sports.
Complete Lesson 2: Pesky Pests and Household Hazards
Examines environmentally friendly ways to keep our homes and schools pest-free. Defines pests, pesticides, household hazards, chemicals, and toxic, and explores strategies for keeping common household hazards out of reach.
Titus, Charles H.; Cohn, Daniel R.; Surma, Jeffrey E.
1998-01-01
The present invention provides a relatively compact self-powered, tunable waste conversion system and apparatus which has the advantage of highly robust operation which provides complete or substantially complete conversion of a wide range of waste streams into useful gas and a stable, nonleachable solid product at a single location with greatly reduced air pollution to meet air quality standards. The system provides the capability for highly efficient conversion of waste into high quality combustible gas and for high efficiency conversion of the gas into electricity by utilizing a high efficiency gas turbine or by an internal combustion engine. The solid product can be suitable for various commercial applications. Alternatively, the solid product stream, which is a safe, stable material, may be disposed of without special considerations as hazardous material. In the preferred embodiment of the invention, the arc plasma furnace and joule heated melter are formed as a fully integrated unit with a common melt pool having circuit arrangements for the simultaneous independently controllable operation of both the arc plasma and the joule heated portions of the unit without interference with one another. The preferred configuration of this embodiment of the invention utilizes two arc plasma electrodes with an elongated chamber for the molten pool such that the molten pool is capable of providing conducting paths between electrodes. The apparatus may additionally be employed with reduced or without further use of the gases generated by the conversion process. The apparatus may be employed as a self-powered or net electricity producing unit where use of an auxiliary fuel provides the required level of electricity production.
NASA Technical Reports Server (NTRS)
Ramohalli, K.
1980-01-01
Attempts to alleviate carbon-fiber-composite electrical hazards during airplane crash fires through fiber gasification are described. Thermogravimetric and differential scanning calorimetric experiments found several catalysts that caused fibers to combust when composites were exposed to test fires. Composites were tested in the 'Burn-Bang' apparatus and in high voltage electrical detection grid apparatus. In a standard three minute burn test modified composites released no fibers, while state-of-the-art composites released several hundred fiber fragments. Expected service life with and without catalytic modification was studied and electron microscopy and X-ray microanalysis furnished physical appearance and chemical composition data. An acrylic acid polymer fiber coating was developed that wet the carbon fiber surface uniformly with the catalyst, providing a marked contrast with the uneven coats obtained by solution-dipping.
Protection of Advanced Electrical Power Systems from Atmospheric Electromagnetic Hazards.
1981-12-01
WORDS (Continue on reverse aide if neceeary and Identify by block number) Aircraft Induced Voltages Filters Composite Structures Lightning Transients...transients on the electrical systems of aircraft with metal or composite structures. These transients will be higher than the equipment inherent hardness... composite material in skin and structure. In addition, the advanced electrical power systems used in these aircraft will contain solid state components
NASA Technical Reports Server (NTRS)
1996-01-01
Under a Lewis Research Center Small Business Innovation Research contract, SRICO, Inc. developed a fiber optic voltage sensor to measure voltage in electronic systems in spacecraft. The sensor uses glass and light to sense and transmit electricity, and is relatively safe and accurate. SRICO then commercialized the sensor for measurement of electric field and voltage in applications such as electric power systems and hazardous environments, lightning detection, and fiber optic communication systems.
Central US earthquake catalog for hazard maps of Memphis, Tennessee
Wheeler, R.L.; Mueller, C.S.
2001-01-01
An updated version of the catalog that was used for the current national probabilistic seismic-hazard maps would suffice for production of large-scale hazard maps of the Memphis urban area. Deaggregation maps provide guidance as to the area that a catalog for calculating Memphis hazard should cover. For the future, the Nuttli and local network catalogs could be examined for earthquakes not presently included in the catalog. Additional work on aftershock removal might reduce hazard uncertainty. Graphs of decadal and annual earthquake rates suggest completeness at and above magnitude 3 for the last three or four decades. Any additional work on completeness should consider the effects of rapid, local population changes during the Nation's westward expansion. ?? 2001 Elsevier Science B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Stone, Henry W.; Edmonds, Gary O.
1995-01-01
Remotely controlled mobile robot used to locate, characterize, identify, and eventually mitigate incidents involving hazardous-materials spills/releases. Possesses number of innovative features, allowing it to perform mission-critical functions such as opening and unlocking doors and sensing for hazardous materials. Provides safe means for locating and identifying spills and eliminates risks of injury associated with use of manned entry teams. Current version of vehicle, called HAZBOT III, also features unique mechanical and electrical design enabling vehicle to operate safely within combustible atmosphere.
Thousands of chemicals have not been characterized for their DNT potential. Due to the need for DNT hazard identification, efforts to develop screening assays for DNT potential is a high priority. Multi-well microelectrode arrays (MEA) measure the spontaneous activity of electr...
46 CFR 111.105-15 - Additional methods of protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Additional methods of protection. 111.105-15 Section 111.105-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-15 Additional methods of protection...
Simple circuit monitors "third wire" in ac lines
NASA Technical Reports Server (NTRS)
Kojima, T. T.; Stuck, D. E.
1980-01-01
Device detects interruption of ground connection in three-wire electrical equipment and shuts off ac power to prevent shock hazard. Silicon-controlled rectifiers detect floating ground, and deenergize optoelectric relays thereby breaking power connections. Circuit could be incorporated into hand tools, appliances, and other electrical equipment.
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
46 CFR 111.105-3 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... reference; see 46 CFR 110.10-1), and with either Articles 500 through 505 of NFPA NEC 2002 (incorporated by... articles, and when installed fittings are approved for the specific hazardous location and the cable type...
NASA Astrophysics Data System (ADS)
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-07-01
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices.
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-01-01
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices. PMID:27457494
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-07-26
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices.
Determining the explosion risk level and the explosion hazard area for a group of natural gas wells
NASA Astrophysics Data System (ADS)
Gligor, A.; Petrescu, V.; Deac, C.; Bibu, M.
2016-11-01
Starting from the fact that the natural gas engineering profession is generally associated with a high occupational risk, the current paper aims to help increase the safety of natural gas wells and reduce the risk of work-related accidents, as well as the occurrence of professional illnesses, by applying an assessment method that has proven its efficiency in other industrial areas in combination with a computer-aided design software. More specifically, the paper focuses on two main research directions: assessing the explosion risk for employees working at natural gas wells and indicating areas with a higher explosion hazard by using a modern software that allows their presentation in 3D. The appropriate zoning of industrial areas allows to group the various functional areas function of the probability of the occurrence of a dangerous element, such as an explosive atmosphere and subsequently it allows also to correctly select the electrical and mechanical equipment that will be used in that area, since electrical apparatuses that are otherwise found in normal work environments cannot generally be used in areas with explosion hazard, because of the risk that an electric spark, an electrostatic discharge etc. ignites the explosive atmosphere.
Cardiac rehabilitation attendance and outcomes in coronary artery disease patients.
Martin, Billie-Jean; Hauer, Trina; Arena, Ross; Austford, Leslie D; Galbraith, P Diane; Lewin, Adriane M; Knudtson, Merril L; Ghali, William A; Stone, James A; Aggarwal, Sandeep G
2012-08-07
Cardiac rehabilitation (CR) is an efficacious yet underused treatment for patients with coronary artery disease. The objective of this study was to determine the association between CR completion and mortality and resource use. We conducted a prospective cohort study of 5886 subjects (20.8% female; mean age, 60.6 years) who had undergone angiography and were referred for CR in Calgary, AB, Canada, between 1996 and 2009. Outcomes of interest included freedom from emergency room visits, hospitalization, and survival in CR completers versus noncompleters, adjusted for clinical covariates, treatment strategy, and coronary anatomy. Hazard ratios for events for CR completers versus noncompleters were also constructed. A propensity model was used to match completers to noncompleters on baseline characteristics, and each outcome was compared between propensity-matched groups. Of the subjects referred for CR, 2900 (49.3%) completed the program, and an additional 554 subjects started but did not complete CR. CR completion was associated with a lower risk of death, with an adjusted hazard ratio of 0.59 (95% confidence interval, 0.49-0.70). CR completion was also associated with a decreased risk of all-cause hospitalization (adjusted hazard ratio, 0.77; 95% confidence interval, 0.71-0.84) and cardiac hospitalization (adjusted hazard ratio, 0.68; 95% confidence interval, 0.55-0.83) but not with emergency room visits. Propensity-matched analysis demonstrated a persistent association between CR completion and reduced mortality. Among those coronary artery disease patients referred, CR completion is associated with improved survival and decreased hospitalization. There is a need to explore reasons for nonattendance and to test interventions to improve attendance after referral.
The rockfall hazard rating system.
DOT National Transportation Integrated Search
1991-11-01
The development and dissemination of the Rockfall Hazard Rating System (RHRS) is complete. RHRS is intended to be a proactive tool that will allow transportation agencies to address rationally their rockfall hazards instead of simply reacting to rock...
49 CFR 175.25 - Notification at air passenger facilities of hazardous materials restrictions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... restrictions on hazardous materials in baggage. (d) Signage. When the check in process is not conducted... permitted and forbidden hazardous materials may be completed through signage (electronic or otherwise...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Onshore Hazardous Liquid Low-Stress Lines AGENCY: Pipeline and Hazardous Materials Safety Administration... pipelines to perform a complete ``could affect'' analysis to determine which rural low-stress pipeline...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... to All Rural Onshore Hazardous Liquid Low-Stress Lines AGENCY: Pipeline and Hazardous Materials... burdensome to require operators of these pipelines to perform a complete ``could affect'' analysis to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Nathanael J. K.; Gearhart, Jared Lee; Jones, Dean A.
Currently, much of protection planning is conducted separately for each infrastructure and hazard. Limited funding requires a balance of expenditures between terrorism and natural hazards based on potential impacts. This report documents the results of a Laboratory Directed Research & Development (LDRD) project that created a modeling framework for investment planning in interdependent infrastructures focused on multiple hazards, including terrorism. To develop this framework, three modeling elements were integrated: natural hazards, terrorism, and interdependent infrastructures. For natural hazards, a methodology was created for specifying events consistent with regional hazards. For terrorism, we modeled the terrorists actions based on assumptions regardingmore » their knowledge, goals, and target identification strategy. For infrastructures, we focused on predicting post-event performance due to specific terrorist attacks and natural hazard events, tempered by appropriate infrastructure investments. We demonstrate the utility of this framework with various examples, including protection of electric power, roadway, and hospital networks.« less
T-SENSE a millimeter wave scanner for letters
NASA Astrophysics Data System (ADS)
Nüßler, Dirk; Heinen, Sven; Sprenger, Thorsten; Hübsch, Daniel; Würschmidt, Tobais
2013-10-01
Letter bombs are an increasing problem for public authorities, companies and public persons. Nowadays every big company uses in his headquarters inspection system to check the incoming correspondence. Generally x-ray systems are used to inspect complete baskets or bags of letters. This concept which works very fine in big company with a large postal center is not usable for small companies or private persons. For an office environment with a small number of letters x-ray systems are too expensive and oversized. X-ray systems visualize the wires and electric circuits inside the envelope. If a letter contains no metallic components but hazard materials or drugs, the dangerous content is invisible for the most low-cost x-ray systems. Millimeter wave imagining systems offer the potential to close this gap.
Hazardous Waste Cleanup: General Electric - Fort Edward in Fort Edward, New York
This 32-acre General Electric (GE) facility is located approximately 800 feet east of the Hudson River between the Villages of Fort Edward to the south and Hudson Falls to the north. A 200-foot-wide parcel west of the main portion of the site, between Alle
Hazardous Waste Cleanup: Caribe General Electric Product in Rio Piedras, Puerto Rico
The Caribe General Electric Product facility (GE Río Piedras) covers approximately 4 acres and is situated on the northern coastal plain in a relatively flat industrial/urban area of Río Piedras with an elevation between 20 and 40 feet above mean sea leve
Hazardous Waste Cleanup: Central Hudson Gas & Electric Corporation in Highland, New York
This site is located about five miles west of the Hudson River in Town of Lloyd, New York, Ulster County. It has operated as a vehicle and equipment storage and repair facility for an electric power transmission company since the 1950's. Both current
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...
Flammability control for electrical cables and connectors
NASA Technical Reports Server (NTRS)
Wick, W. O.; Buckey, D. L.
1973-01-01
Technique of covering fire-hazardous sections of electrical wiring with fireproof materials prevents fires from spreading in oxygen-enriched atmospheres and eliminates use of heavy metal enclosures. Materials used to cover potting on connectors and ground terminals are made from Teflon-coated Beta cloth and Fluorel, a nonflammable fully-saturated polymer.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-24
... Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial- Institutional, and... Standards of Performance for Fossil-Fuel- Fired Electric Utility, Industrial-Commercial-Institutional, and...). Certain other material, such as copyrighted material, will be publicly available only in hard copy form...
46 CFR 111.106-1 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Applicability. 111.106-1 Section 111.106-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations on OSVs § 111.106-1 Applicability. This subpart applies to OSVs of at least 6...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-04
... Design,'' GDC 31, ``Fracture Prevention of Reactor Coolant Pressure Boundary,'' and GDC 32, ``Inspection... Operating Company; Vogtle Electric Generating Plant, Unit Nos. 1 and 2; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration...
18 CFR 1304.209 - Land-based structures/alterations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... steps, pathways, boat launching ramps, marine railways located in the access corridor, bank... (electric, water-intake lines, etc.) may be placed within the access corridor as follows: (1) Power lines, poles, electrical panel, and wiring must be installed: (i) In a way that would not be hazardous to the...
Lightning Discharges to Aircraft and Associated Meteorological Conditions
NASA Technical Reports Server (NTRS)
Harrison, L P
1946-01-01
A summary is given of information on atmospheric electrical discharges to aircraft and associated meteorological conditions. Information is given that is designed to give a fairly comprehensive view of the underlying principles of meteorology and atmospheric electricity. Of special interest to pilots are lists of procedures of flight conduct and aircraft maintenance recommended foe avoiding or minimizing the hazards of disruptive electrical discharges and other severe conditions near thunderstorms.
Non-therapist identification of falling hazards in older adult homes using digital photography.
Ritchey, Katherine C; Meyer, Deborah; Ice, Gillian H
2015-01-01
Evaluation and removal of home hazards is an invaluable method for preventing in-home falls and preserving independent living. Current processes for conducting home hazard assessments are impractical from a whole population standpoint given the substantial resources required for implementation. Digital photography offers an opportunity to remotely evaluate an environment for falling hazards. However, reliability of this method has only been tested under the direction of skilled therapists. Ten community dwelling adults over the age of 65 were recruited from local primary care practices between July, 2009 and February, 2010. In-home (IH) assessments were completed immediately after a photographer, blinded to the assessment form, took digital photographs (DP) of the participant home. A different non-therapist assessor then reviewed the photographs and completed a second assessment of the home. Kappa statistic was used to analyze the reliability between the two independent assessments. Home assessments completed by a non-therapist using digital photographs had a substantial agreement (Kappa = 0.61, p < 0.001) with in-home assessments completed by another non-therapist. Additionally, the DP assessments agreed with the IH assessments on the presence or absence of items 96.8% of the time. This study showed that non-therapists can reliably conduct home hazard evaluations using digital photographs.
HAZARDS SUMMARY REPORT FOR A TWO WATT PROMETHIUM-147 FUELED THERMOELECTRIC GENERATOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1959-06-01
Discussions are included of the APU design, vehicle integration, Pm/sup 147/ properties, shielding requirements, hazards design criteria, statistical analysis for impact, and radiation protection. The use of Pm/sup 147/ makes possible the fabrication of an auxiliary power unit which has applications for low power space missions of <10 watts (electrical). (B.O.G.)
"Making Do" Decisions: How Home Healthcare Personnel Manage Their Exposure to Home Hazards.
Wills, Celia E; Polivka, Barbara J; Darragh, Amy; Lavender, Steven; Sommerich, Carolyn; Stredney, Donald
2016-04-01
This study describes the decision-making processes home healthcare personnel (HHP) use to manage their personal health and safety when managing hazards in client homes. A professionally diverse national sample of 68 HHP participated in individual semi-structured interviews and focus group discussions, and described their decision making and strategies for hazard management in their work environments. HHP described 353 hazard management dilemmas within 394 specifically identified hazards, which were clustered within three broader categories: electrical/fire, slip/trip/lift, and environmental exposures. HHP described multiple types of "making do" decisions for hazard management solutions in which perceived and actual resource limitations constrained response options. A majority of hazard management decisions in the broader hazards categories (72.5%, 68.5%, and 63.5%, respectively) were classifiable as less than optimal. These findings stress the need for more support of HHPs, including comprehensive training, to improve HHP decision making and hazard management strategies, especially in context of resource constraints. © The Author(s) 2015.
“Making Do” Decisions: How Home Healthcare Personnel Manage Their Exposure to Home Hazards
Wills, Celia E.; Polivka, Barbara J.; Darragh, Amy; Lavender, Steven; Sommerich, Carolyn; Stredney, Donald
2016-01-01
This study describes the decision-making processes home healthcare personnel (HHP) use to manage their personal health and safety when managing hazards in client homes. A professionally diverse national sample of 68 HHP participated in individual semi-structured interviews and focus group discussions, and described their decision making and strategies for hazard management in their work environments. HHP described 353 hazard management dilemmas within 394 specifically identified hazards, which were clustered within three broader categories: electrical/fire, slip/trip/lift, and environmental exposures. HHP described multiple types of “making do” decisions for hazard management solutions in which perceived and actual resource limitations constrained response options. A majority of hazard management decisions in the broader hazards categories (72.5%, 68.5%, and 63.5%, respectively) were classifiable as less than optimal. These findings stress the need for more support of HHPs, including comprehensive training, to improve HHP decision making and hazard management strategies, especially in context of resource constraints. PMID:26669605
Ma, Changxi; Hao, Wei; Pan, Fuquan; Xiang, Wang
2018-01-01
Route optimization of hazardous materials transportation is one of the basic steps in ensuring the safety of hazardous materials transportation. The optimization scheme may be a security risk if road screening is not completed before the distribution route is optimized. For road screening issues of hazardous materials transportation, a road screening algorithm of hazardous materials transportation is built based on genetic algorithm and Levenberg-Marquardt neural network (GA-LM-NN) by analyzing 15 attributes data of each road network section. A multi-objective robust optimization model with adjustable robustness is constructed for the hazardous materials transportation problem of single distribution center to minimize transportation risk and time. A multi-objective genetic algorithm is designed to solve the problem according to the characteristics of the model. The algorithm uses an improved strategy to complete the selection operation, applies partial matching cross shift and single ortho swap methods to complete the crossover and mutation operation, and employs an exclusive method to construct Pareto optimal solutions. Studies show that the sets of hazardous materials transportation road can be found quickly through the proposed road screening algorithm based on GA-LM-NN, whereas the distribution route Pareto solutions with different levels of robustness can be found rapidly through the proposed multi-objective robust optimization model and algorithm.
Compressed Gas Safety for Experimental Fusion Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee C. Cadwallader
2004-09-01
Experimental fusion facilities present a variety of hazards to the operators and staff. There are unique or specialized hazards, including magnetic fields, cryogens, radio frequency emissions, and vacuum reservoirs. There are also more general industrial hazards, such as a wide variety of electrical power, pressurized air, and cooling water systems in use, there are crane and hoist loads, working at height, and handling compressed gas cylinders. This paper outlines the projectile hazard assoicated with compressed gas cylinders and mthods of treatment to provide for compressed gas safety. This information should be of interest to personnel at both magnetic and inertialmore » fusion experiments.« less
1983-08-01
ATCD-S 1 VEHICLES FORT MONROE VA 23651 ATTN: DRCPM-MI13 WARREN MI 48090 CDR US ARMY TRANSPORTATION SCHOOL PROJ MGR, MOBILE ELECTRIC POWER ATTN: ATS P-CD...for the Deutz F3L 912W and the Perkins 4.203.2 49 6 / t . . ...... ....low I. INTRODUCTION The U.S. Army currently uses electric forklifts in handling...hazardous materials. Although these electric forklifts have certain inherent desirable characteristics, i.e., no pollution or noise, the logistics
NASA Astrophysics Data System (ADS)
Lee, T. S.; Robb, J. D.
The ring discharge hazard to a carbon-reinforced-composites fuel tank skin under lightning strike conditions is investigated. A model of anisotropy in electric conductivity is adopted whereby longitudinal conductivity and transverse conductivity are considered separately. It is concluded that the current flow pattern contains a stagnation-dominated near-field region and a geometry-dominated far-field decaying region. While this pattern is unaltered by anisotropy in conductivity, the accompanying nonliner electrical field pattern is greatly distorted. It is noted that conclusions applicable to the ignition hazard which were derived from the model of a uniform scalar conductivity for the skin still remain intact.
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-25
... Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial- Commercial-Institutional, and... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility.... Electronic files should avoid the use of special characters, any form of encryption, and be free of any...
Code of Federal Regulations, 2010 CFR
2010-10-01
... transported under deck, provided the following requirements are met: (1) The cargo space shall be provided... in accordance with the requirements under which they were manufactured. (7) Electrical circuits in the cargo spaces must meet the hazardous area requirements in subchapter J (Electrical Engineering...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
78 FR 23308 - Petitions for Modification of Application of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-18
... electrical condition of the slope conveyor system. (c) Immediate reporting of any hazards or mechanical... Affected: 30 CFR 75.1710-1(a)(4) (Canopies or cabs; self-propelled diesel-powered and electric face... existing standard to permit the use of shuttle cars without canopies in heights less than forty eight...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
30 CFR 56.4600 - Extinguishing equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., soldering, thawing, or bending— (1) With an electric arc or with an open flame where an electrically... extinguisher or other extinguisher with at least a 2-A:10-B:C rating shall be at the worksite. (2) With an open... equivalent fire extinguishing equipment for the class of fire hazard present shall be at the worksite. (b...
Small-diameter timber alchemy: can utilization pay the way toward fire-resistant forests
Jeremy S. Fried; R. Jamie Barbour; Roger D. Fight; Glenn Christensen; Guy Pinjuv
2008-01-01
There is growing interest in using biomass removed from hazardous fuels reduction treatments in wood-fired electrical generation facilities. An application of FIA BioSum to southwest Oregonâs Klamath ecoregion assessed the financial feasibility of fuel treatment and biomass generation under a range of product prices and fire hazard-motivated silvicultural prescriptions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... accumulate on electrical installations, wiring shall be in rigid conduit or in boxes containing no taps... pressure. (12) Wiring, motors and equipment in a spray booth shall be of approved explosion-proof type for..., Hazardous Locations. Wiring, motors and equipment within 20 feet (6.1m) of any interior spraying area and...
Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…
Autonomous Precision Landing and Hazard Avoidance Technology (ALHAT) Project Status as of May 2010
NASA Technical Reports Server (NTRS)
Striepe, Scott A.; Epp, Chirold D.; Robertson, Edward A.
2010-01-01
This paper includes the current status of NASA s Autonomous precision Landing and Hazard Avoidance Technology (ALHAT) Project. The ALHAT team has completed several flight tests and two major design analysis cycles. These tests and analyses examine terrain relative navigation sensors, hazard detection and avoidance sensors and algorithms, and hazard relative navigation algorithms, and the guidance and navigation system using these ALHAT functions. The next flight test is scheduled for July 2010. The paper contains results from completed flight tests and analysis cycles. ALHAT system status, upcoming tests and analyses is also addressed. The current ALHAT plans as of May 2010 are discussed. Application of the ALHAT system to landing on bodies other than the Moon is included
Physical hazard safety awareness among healthcare workers in Tanta university hospitals, Egypt.
El-Sallamy, Rania M; Kabbash, Ibrahim Ali; El-Fatah, Sanaa Abd; El-Feky, Asmaa
2017-05-17
Hospital workers are exposed to many occupational hazards that may threaten their health and safety. Physical hazards encountered in hospital working environment include temperature, illumination, noise, electrical injuries, and radiation. To assess the awareness of healthcare workers (HCWs) about physical hazards in Tanta university hospitals, this cross-sectional study included 401 HCWs (physicians, nurses, technicians, and workers) from seven departments (general surgery, orthopedics, radiology, ophthalmology, kitchen, incinerator, and laundry). Data were collected through interview questionnaire to assess six types of physical hazards (noise, electric hazards, temperature, radiation, fire, and lighting,). Most of the physicians (63.7%) were aware of the level of noise. All physicians, nurses, technicians, and majority of workers reported that hearing protective devices were not available, and all HCWs reported that periodic hearing examination was not performed. Most of the nurses (75.2%) and workers (68.5%) did not attended emergency training, and more than two thirds of all HCWs were not briefed about emergency evacuation. Most HCWs were not given appropriate radiation safety training before starting work (88% of workers, 73.7% of nurses, 65.7% of physicians, and 68.3% of technicians). The majority of physicians, nurses, and technicians (70.5, 65.4, and 53.7%) denied regular environmental monitoring for radiation level inside work place. Health education programs on health and safety issues regarding physical hazards should be mandatory to all healthcare workers to improve their awareness and protect them from undue exposures they may face due to lack of adequate awareness and knowledge. There is urgent need of expanding the occupational healthcare services in Egypt to cover all the employees as indicated by the international recommendations and the Egyptian Constitution, legislation, and community necessity.
1984-12-01
AFLRL No. 178 By oi Harry E. Dietzmann ,< Engines, Emissions.and Vehicle Research Division Southwest Research Institute San Antonio, Texas Prppared...the possibility of replacing the currently used electric forklift with diesel engine-powered forklifts in handling hazardous materials. Electric ...concern; however, these concerns may be amplified when the vehicle is operating under a malfunction mode. Malfunctions include simulating a plugged
Solar Water Heater Installation Package
NASA Technical Reports Server (NTRS)
1982-01-01
A 48-page report describes water-heating system, installation (covering collector orientation, mounting, plumbing and wiring), operating instructions and maintenance procedures. Commercial solar-powered water heater system consists of a solar collector, solar-heated-water tank, electrically heated water tank and controls. Analysis of possible hazards from pressure, electricity, toxicity, flammability, gas, hot water and steam are also included.
Liquid phase deposition of a space-durable, antistatic SnO₂ coating on Kapton.
Gotlib-Vainstein, Katya; Gouzman, Irina; Girshevitz, Olga; Bolker, Asaf; Atar, Nurit; Grossman, Eitan; Sukenik, Chaim N
2015-02-18
Polyimides are widely used in thermal blankets covering the external surfaces of spacecrafts due to their space durability and their thermo-optical properties. However, they are susceptible to atomic oxygen (AO) erosion, the main hazard of low Earth orbit (LEO), and to electrical charging. This work demonstrates that liquid phase deposition (LPD) of 100 nm of tin oxide creates a protective coating on Kapton polyimide that has good adherence and is effective in preventing AO-induced surface erosion and in reducing electrical charging. The as-deposited tin oxide induces no significant changes in the original thermo-optical properties of the polymer and is effective in preventing electrostatic discharge (ESD). The durability of the oxide coating under AO attack was studied using oxygen RF plasma. The AO exposure did not result in any significant changes in surface morphology, thermo-optical, mechanical, and electrical properties of the tin oxide-coated Kapton. The erosion yield of tin oxide-coated Kapton was negligible after exposure to 6.4 × 10(20) O atoms·cm(-2) of LEO equivalent AO fluence, indicating a complete protection of Kapton by the LPD deposited coating. Moreover, the tin oxide coating is flexible enough so that its electrical conductivity stays within the desired range of antistatic materials despite mechanical manipulations. The advantages of liquid phase deposited oxides in terms of their not being line of site limited are well established. We now extend these advantages to coatings that reduce electrostatic discharge while still providing a high level of protection from AO erosion.
Hazard calculations of diffuse reflected laser radiation for the SELENE program
NASA Technical Reports Server (NTRS)
Miner, Gilda A.; Babb, Phillip D.
1993-01-01
The hazards from diffuse laser light reflections off water clouds, ice clouds, and fog and from possible specular reflections off ice clouds were assessed with the American National Standards (ANSI Z136.1-1986) for the free-electron-laser parameters under consideration for the Segmented Efficient Laser Emission for Non-Nuclear Electricity (SELENE) Program. Diffuse laser reflection hazards exist for water cloud surfaces less than 722 m in altitude and ice cloud surfaces less than 850 m in altitude. Specular reflections from ice crystals in cirrus clouds are not probable; however, any specular reflection is a hazard to ground observers. The hazard to the laser operators and any ground observers during heavy fog conditions is of such significant magnitude that the laser should not be operated in fog.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bridges, J.E.; Frazier, M.J.
1979-09-01
The effects of 60-Hz electric and magnetic fields of exta-high voltage (EHV) transmission lines on the performance of implanted cardiac pacemakers were studied by: (1) in vitro bench tests of a total of thirteen cardiac pacemakers; (2) in vivo tests of six implanted cardiac pacemakers in baboons; and (3) non-hazardous skin measurement tests on four humans. Analytical methods were developed to predict the thresholds of body current and electric fields capable of affecting normal pacemaker operation in humans. The field strengths calculated to alter implanted pacemaker performance were compared with the range of maximum electric and magnetic field strengths amore » human would normally encounter under transmission lines of various voltages. Results indicate that the electric field or body current necessary to alter the normal operation of pacemakers is highly dependent on the type of pacemaker and the location of the implanted electrodes. However, cardiologists have not so far detected harmful effects of pacemaker reversion to the asynchronous mode in current types of pacemakers and with present methods of implantation. Such interferences can be eliminated by using advanced pacemakers less sensitive to 60-Hz voltages or by using implantation lead arrangements less sensitive to body current.« less
Apparatus for the plasma destruction of hazardous gases
Kang, M.
1995-02-07
A plasma cell for destroying hazardous gases is described. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required. 4 figs.
Apparatus for the plasma destruction of hazardous gases
Kang, Michael
1995-01-01
A plasma cell for destroying hazardous gases. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required.
Risk assessment for safety laboratories in Politeknik Negeri Medan
NASA Astrophysics Data System (ADS)
Viyata Sundawa, Bakti; Hutajulu, Elferida; Sirait, Regina; Banurea, Waldemar; Indrayadi; Mulyadi, Sangap
2017-09-01
International Labour Organization (ILO) estimated 2.34 million people die each year because accidents and diseases in workplace. It also impact to economic losses in some countries. It need to do safety and healthy in working environment especially in laboratory. Identification of potential hazards and risks must be done in Telecommunication Laboratory Politeknik Negeri Medan. Therefore, this study was assessed 5 of potential hazards and risks in our laboratory by Likert Scale. This object was divided into 2 assessment namely likelihood of hazards and severity of consequences. Collecting data is taken from questionnaire who involved 100 students at random academic level. The result showed The highest score is chemical hazards 73.2% in likelihood of hazards and electrical hazards 85% in severity of consequences. This condition is classified as “high” state. Big attention must be given to “high” state because it can help us to determine mitigate action.
Cocron, Peter; Bachl, Veronika; Früh, Laura; Koch, Iris; Krems, Josef F
2014-12-01
The low noise emission of battery electric vehicles (BEVs) has led to discussions about how to address potential safety issues for other road users. Legislative actions have already been undertaken to implement artificial sounds. In previous research, BEV drivers reported that due to low noise emission they paid particular attention to pedestrians and bicyclists. For the current research, we developed a hazard detection task to test whether drivers with BEV experience respond faster to incidents, which arise due to the low noise emission, than inexperienced drivers. The first study (N=65) revealed that BEV experience only played a minor role in drivers' response to hazards resulting from low BEV noise. The tendency to respond, reaction times and hazard evaluations were similar among experienced and inexperienced BEV drivers; only small trends in the assumed direction were observed. Still, both groups clearly differentiated between critical and non-critical scenarios and responded accordingly. In the second study (N=58), we investigated additionally if sensitization to low noise emission of BEVs had an effect on hazard perception in incidents where the noise difference is crucial. Again, participants in all groups differentiated between critical and non-critical scenarios. Even though trends in response rates and latencies occurred, experience and sensitization to low noise seemed to only play a minor role in detecting hazards due to low BEV noise. An additional global evaluation of BEV noise further suggests that even after a short test drive, the lack of noise is perceived more as a comfort feature than a safety threat. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hydrothermal Liquefaction Treatment Preliminary Hazard Analysis Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowry, Peter P.; Wagner, Katie A.
A preliminary hazard assessment was completed during February 2015 to evaluate the conceptual design of the modular hydrothermal liquefaction treatment system. The hazard assessment was performed in 2 stages. An initial assessment utilizing Hazard Identification and Preliminary Hazards Analysis (PHA) techniques identified areas with significant or unique hazards (process safety-related hazards) that fall outside of the normal operating envelope of PNNL and warranted additional analysis. The subsequent assessment was based on a qualitative What-If analysis. This analysis was augmented, as necessary, by additional quantitative analysis for scenarios involving a release of hazardous material or energy with the potential for affectingmore » the public.« less
The paper discusses measurement issues relating to the characterization of organic emissions from hazardous waste incineration processes under EPA's new risk burn guidance. The recently published draft quidance recommends that hazardous waste combustion facilities complete a mass...
Code of Federal Regulations, 2012 CFR
2012-07-01
... FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK General § 154.105 Definitions. As used in this part... equipment in the marine transfer area are completely free of oil or hazardous materials, where these..., used or capable of being used to transfer oil or hazardous materials to or from a vessel or public...
Code of Federal Regulations, 2011 CFR
2011-07-01
... FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK General § 154.105 Definitions. As used in this part... equipment in the marine transfer area are completely free of oil or hazardous materials, where these..., used or capable of being used to transfer oil or hazardous materials to or from a vessel or public...
40 CFR 265.120 - Certification of completion of post-closure care.
Code of Federal Regulations, 2010 CFR
2010-07-01
... each hazardous waste disposal unit, the owner or operator must submit to the Regional Administrator, by registered mail, a certification that the post-closure care period for the hazardous waste disposal unit was...) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT...
Electrical burn injuries of workers using portable aluminium ladders near overhead power lines.
Moghtader, J C; Himel, H N; Demun, E M; Bellian, K T; Edlich, R F
1993-10-01
The use of aluminium ladders around high voltage power lines has resulted in a significant number of electrical injuries and electrocutions. Workers often misjudge wire distances or lose control of fully extended ladders, thereby exposing themselves to electrocution hazard. High-voltage electrical burns of two workers using an aluminium ladder that contacted a high voltage power line are reported. The circumstances surrounding the injury, the clinical management of the case, and the methods of prevention are presented and discussed.
Fadeyibi, I.O.; Izegbu, M.C.; Benebo, A.S.; Ademuluyi, S.A.
2007-01-01
Summary The case reported is that of a communications technician admitted to hospital with 38% burns sustained while climbing a communications mast. The mast was erected less than 3 metres from a 33 kv electric transmission cable. His condition is described, as also the treatment he received until his discharge three months later. In the absence of guidelines regarding the erection of such masts, a number of recommendations are made. PMID:21991082
FROM CONCEPT TO REALITY, IN-SITU DECOMMISSIONING OF THE P AND R REACTORS AT THE SAVANNAH RIVER SITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musall, J.; Blankenship, J.; Griffin, W.
2012-01-09
SRS recently completed an approximately three year effort to decommission two SRS reactors: P-Reactor (Building 105-P) and R-Reactor (Building 105-R). Completed in December 2011, the concurrent decommissionings marked the completion of two relatively complex and difficult facility disposition projects at the SRS. Buildings 105-P and 105-R began operating as production reactors in the early 1950s with the mission of producing weapons material (e.g., tritium and plutonium-239). The 'P' Reactor and was shutdown in 1991 while the 'R' Reactor and was shutdown in 1964. In the intervening period between shutdown and deactivation & decommissioning (D&D), Buildings 105-P and 105-R saw limitedmore » use (e.g., storage of excess heavy water and depleted uranium oxide). For Building 105-P, deactivation was initiated in April 2007 and was essentially complete by June 2010. For Building 105-R, deactivation was initiated in August 2008 and was essentially complete by September 2010. For both buildings, the primary objective of deactivation was to remove/mitigate hazards associated with the remaining hazardous materials, and thus prepare the buildings for in-situ decommissioning. Deactivation removed the following hazardous materials to the extent practical: combustibles/flammables, residual heavy water, acids, friable asbestos (as needed to protect workers performing deactivation and decommissioning), miscellaneous chemicals, lead/brass components, Freon(reg sign), oils, mercury/PCB containing components, mold and some radiologically-contaminated equipment. In addition to the removal of hazardous materials, deactivation included the removal of hazardous energy, exterior metallic components (representing an immediate fall hazard), and historical artifacts along with the evaporation of water from the two Disassembly Basins. Finally, so as to facilitate occupancy during the subsequent in-situ decommissioning, deactivation implemented repairs to the buildings and provided temporary power.« less
EMP/GMD Phase 0 Report, A Review of EMP Hazard Environments and Impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera, Michael Kelly; Backhaus, Scott N.; Woodroffe, Jesse Richard
The purpose of this study is to determine methods to analyze the hazard environments, impacts, and consequences of different sources of electromagnetic pulse (EMP), including nuclear electromagnetic pulse (NEMP) and geomagnetic disturbance (GMD) on the U.S. electric power infrastructures and to use those methods to determine EMP and GMD events of concern. The study will be carried out in four phases, each of which will provide higher levels of analytic fidelity that focuses on those EMP/GMD sources and events that create significant consequences, or whose consequences are sufficiently uncertain, to require more in-depth study. This study will leverage the bestmore » experimental data; device, equipment and system models; and simulation tools currently available. This study focuses primarily on the bulk electric system (BES) including large generating stations, large power transformers, the transmission network, and transmission system protection. Electrical distribution systems may potentially be included, if warranted, after consideration of the consequences for the bulk power system.« less
NASA Astrophysics Data System (ADS)
Ohsawa, A.
2011-06-01
This paper presents a statistical analysis of 153 accidents attributable to static electricity in Japanese industry over the last 50 years. A more thorough understanding of their causes could help prevent similar incidents and identify hazards that could assist in the task of risk assessment. Most of the incidents occurred during operations performed by workers. In addition, more than 70% of the flammable atmospheres resulted from the presence of vapours. A noteworthy finding is that at least 70% of the ignitions were caused by isolated conductors including operators' bodies leading to spark discharges, which could have easily been prevented with earthing. These tendencies indicate that, when operators handle flammable liquids with any conductors, the ignition risk is significantly high. A serious lack of information regarding fundamental countermeasures for static electricity seems to be the main cause of such hazards. Only organised management, including education and risk communication, would prevent them.
ERIC Educational Resources Information Center
Calcagno, Juan Carlos; Crosta, Peter; Bailey, Thomas; Jenkins, Davis
2007-01-01
Research has consistently shown that older students--those who enter college for the first time at age 25 or older--are less likely to complete a degree or certificate. The authors estimate a single-risk discrete-time hazard model using transcript data on a cohort of first-time community college students in Florida to compare the educational…
Olsen, Morten; Hjortdal, Vibeke E; Mortensen, Laust H; Christensen, Thomas D; Sørensen, Henrik T; Pedersen, Lars
2011-04-01
Congenital heart defect patients may experience neurodevelopmental impairment. We investigated their educational attainments from basic schooling to higher education. Using administrative databases, we identified all Danish patients with a cardiac defect diagnosis born from 1 January, 1977 to 1 January, 1991 and alive at age 13 years. As a comparison cohort, we randomly sampled 10 persons per patient. We obtained information on educational attainment from Denmark's Database for Labour Market Research. The study population was followed until achievement of educational levels, death, emigration, or 1 January, 2006. We estimated the hazard ratio of attaining given educational levels, conditional on completing preceding levels, using discrete-time Cox regression and adjusting for socio-economic factors. Analyses were repeated for a sub-cohort of patients and controls born at term and without extracardiac defects or chromosomal anomalies. We identified 2986 patients. Their probability of completing compulsory basic schooling was approximately 10% lower than that of control individuals (adjusted hazard ratio = 0.79, ranged from 0.75 to 0.82 0.79; 95% confidence interval: 0.75-0.82). Their subsequent probability of completing secondary school was lower than that of the controls, both for all patients (adjusted hazard ratio = 0.74; 95% confidence interval: 0.69-0.80) and for the sub-cohort (adjusted hazard ratio = 0.80; 95% confidence interval: 0.73-0.86). The probability of attaining a higher degree, conditional on completion of youth education, was affected both for all patients (adjusted hazard ratio = 0.88; 95% confidence interval: 0.76-1.01) and for the sub-cohort (adjusted hazard ratio = 0.92; 95% confidence interval: 0.79-1.07). The probability of educational attainment was reduced among long-term congenital heart defect survivors.
Risk Perception and the Psychology of Natural Hazard Preparedness
NASA Astrophysics Data System (ADS)
Thompson, K. J.; Weber, E. U.
2014-12-01
In the preparedness phase of the disaster cycle, willingness to invest resources in prevention and mitigation doesn't depend only on quantitative judgments of the probability of a disaster. People also evaluate the risks of situations in qualitative ways. Psychological studies of risk perception have shown that risk attitudes toward everyday technologies and activities (e.g., electric power, air travel, smoking) can be mapped onto two orthogonal dimensions: how unknown the risks seem, and how dread or severe they feel. Previously, this psychometric approach to risk perception has focused mostly on man-made risks (e.g., Fischhoff et al. 1978, Slovic 1987). In this paper we examine how natural hazards fit into the established unknown/dread risk space. Hazards that are high on the unknown dimension of risk tend to be perceived as having effects that are unknown to science and to the exposed, uncontrollable, and new. Hazards that rank high on the dread/severity dimension are seen as immediate, catastrophic, highly dreaded on a gut level, new, and likely to be fatal. Perceived risk tends to be highest for hazards that are both high on the dread dimension and low on the unknown dimension. We find that weather-related hazards rank lowest on both dimensions: blizzards, heat waves, hailstorms, fog, and ice storms are all feel very known and not particularly dread. The exception for this group is hurricanes and tornadoes, which are viewed as more similar to geophysical hazards and mass movements: high on dread, though not particularly unknown. Two notable outliers are climate change and sea-level rise, which are both considered very unknown (higher than any other natural hazard save sinkholes), and not at all dread (less dread even than fog and dust storms). But when compared with perceptions of technological hazards, nearly every natural hazard ranks as more dread than any technology or activity, including nuclear power. Man-made hazards fall with technologies, rather than with natural hazards—climate change and sea-level rise are both only as dread as electric power and motor vehicles, yet feel as unknown as terrorism and GMO foods. We discuss the implications of these qualitative elements of hazard risk perception for the preparedness phase of the disaster lifecycle, and offer recommendations to practitioners and educators.
Assessment and Control of Spacecraft Charging Risks on the International Space Station
NASA Technical Reports Server (NTRS)
Koontz, Steve; Edeen, Marybeth; Spetch, William; Dalton, Penni; Keening, Thomas
2003-01-01
Electrical interactions between the F2 region ionospheric plasma and the 160V photovoltaic (PV) electrical power system on the International Space Station (ISS) can produce floating potentials (FP) on the ISS conducting structure of greater magnitude than are usually observed on spacecraft in low-Earth orbit. Flight through the geomagnetic field also causes magnetic induction charging of ISS conducting structure. Charging processes resulting from interaction of ISS with auroral electrons may also contribute to charging albeit rarely. The magnitude and frequency of occurrence of possibly hazardous charging events depends on the ISS assembly stage (six more 160V PV arrays will be added to ISS), ISS flight configuration, ISS position (latitude and longitude), and the natural variability in the ionospheric flight environment. At present, ISS is equipped with two plasma contactors designed to control ISS FP to within 40 volts of the ambient F2 plasma. The negative-polarity grounding scheme utilized in the ISS 160V power system leads, naturally, to negative values of ISS FP. A negative ISS structural FP leads to application of electrostatic fields across the dielectrics that separate conducting structure from the ambient F2 plasma, thereby enabling dielectric breakdown and arcing. Degradation of some thermal control coatings and noise in electrical systems can result. Continued review and evaluation of the putative charging hazards, as required by the ISS Program Office, revealed that ISS charging could produce a risk of electric shock to the ISS crew during extra vehicular activity. ISS charging risks are being evaluated in ongoing ISS charging measurements and analysis campaigns. The results of ISS charging measurements are combined with a recently developed detailed model of the ISS charging process and an extensive analysis of historical ionospheric variability data, to assess ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA analysis (estimated frequency of occurrence and severity of the charging hazards) are then used to select the hazard control strategy that provides the best overall safety and mission success environment for ISS and the ISS crew. This paper presents: 1) a summary of ISS spacecraft charging analysis, measurements, observations made to date, 2) plans for future ISS spacecraft charging measurement campaigns, and 3) a detailed discussion of the PRA strategy used to assess ISS spacecraft charging risks and select charging hazard control strategies
Assessment and Control of International Space Station Spacecraft Charging Risks
NASA Astrophysics Data System (ADS)
Koontz, S.; Edeen, M.; Spetch, W.; Dalton, P.; Keeping, T.; Minow, J.
2003-12-01
Electrical interactions between the F2 region ionospheric plasma and the 160V photovoltaic (PV) electrical power system on the International Space Station (ISS) can produce floating potentials (FP) on ISS conducting structure of greater magnitude than are usually observed on spacecraft in low-Earth orbit. Flight through the geomagnetic field also causes magnetic induction charging of ISS conducting structure. Charging processes resulting from interaction of ISS with auroral electrons may also contribute to charging, albeit rarely. The magnitude and frequency of occurrence of possibly hazardous charging events depends on the ISS assembly stage (six more 160V PV arrays will be added to ISS), ISS flight configuration, ISS position (latitude and longitude), and the natural variability in the ionospheric flight environment. At present, ISS is equipped with two plasma contactors designed to control ISS FP to within 40 volts of the ambient F2 plasma. The negative-polarity grounding scheme utilized in the ISS 160V power system leads, naturally, to negative values of ISS FP. A negative ISS structural FP leads to application of electrostatic fields across the dielectrics that separate conducting structure from the ambient F2 plasma, thereby enabling dielectric breakdown and arcing. Degradation of some thermal control coatings and noise in electrical systems can result. Continued review and evaluation of the putative charging hazards, as required by the ISS Program Office, revealed that ISS charging could produce a risk of electric shock to the ISS crew during extra vehicular activity. ISS charging risks are being evaluated in ongoing ISS charging measurements and analysis campaigns. The results of ISS charging measurements are combined with a recently developed detailed model of the ISS charging process and an extensive analysis of historical ionospheric variability data, to assess ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA analysis (estimated frequency of occurrence and severity of the charging hazards) are then used to select the hazard control strategy that provides the best overall safety and mission success environment for ISS and the ISS crew. This paper presents: 1) a summary of ISS spacecraft charging analysis, measurements, observations made to date, 2) plans for future ISS spacecraft charging measurement campaigns, and 3) a detailed discussion of the PRA strategy used to assess ISS spacecraft charging risks and select charging hazard control strategies.
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Additional requirements for vessels carrying vehicles with fuel in their tanks. 111.105-39 Section 111.105-39 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels...
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Additional requirements for vessels carrying vehicles with fuel in their tanks. 111.105-39 Section 111.105-39 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels...
Safety in the Physics Laboratory
ERIC Educational Resources Information Center
Bullen, Brother T. G.
1974-01-01
Briefly defines the legal aspects of safety. Presents prominent safety hazards and procedures that should be followed when dealing with electricity, radioactive materials, lasers, poisons, and vacuum apparatus. (GS)
... safety procedures and operating instructions before operating any gas-powered or electric-powered saws or tools. Clean up spilled medicines, drugs, flammable liquids, and other potentially hazardous materials. Children's Needs After ...
[Biosafety in laboratories concerning exposure to biological agents].
Vonesch, N; Tomao, P; Di Renzi, S; Vita, S; Signorini, S
2006-01-01
Laboratory workers are exposed to a variety of potential occupational health hazards including those deriving from infectious materials and cultures, radiations, toxic and flammable chemicals, as well as mechanical and electrical hazard. Although all of them are significant, this paper will focus on biological hazards present in clinical and research laboratories. In fact, in spite of numerous publications, guidelines and regulations, laboratory workers are still subject to infections acquired in the course of their researches. This paper describes some aspects that include good microbiological practices (GMPs), appropriate containment equipment, practices and operational procedures to minimize workers' risk of injury or illness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gan, Yong X., E-mail: yong.gan@utoledo.edu; Gan, Bo J.; Clark, Evan
2012-09-15
Highlights: ► A photoelectrochemical fuel cell has been made from TiO{sub 2} nanotubes. ► The fuel cell decomposes environmentally hazardous materials to produce electricity. ► Doping the anode with a transition metal oxide increases the visible light sensitivity. ► Loading the anode with a conducting polymer enhances the visible light absorption. -- Abstract: In this work, a novel photoelectrochemical fuel cell consisting of a titanium dioxide nanotube array photosensitive anode and a platinum cathode was made for decomposing environmentally hazardous materials to produce electricity and clean fuel. Titanium dioxide nanotubes (TiO{sub 2} NTs) were prepared via electrochemical oxidation of puremore » Ti in an ammonium fluoride and glycerol-containing solution. Scanning electron microscopy was used to analyze the morphology of the nanotubes. The average diameter, wall thickness and length of the as-prepared TiO{sub 2} NTs were determined. The photosensitive anode made from the highly ordered TiO{sub 2} NTs has good photo-catalytic property, as proven by the decomposition tests on urea, ammonia, sodium sulfide and automobile engine coolant under ultraviolet (UV) radiation. To improve the efficiency of the fuel cell, doping the TiO{sub 2} NTs with a transition metal oxide, NiO, was performed and the photosensitivity of the doped anode was tested under visible light irradiation. It is found that the NiO-doped anode is sensitive to visible light. Also found is that polyaniline-doped photosensitive anode can harvest photon energy in the visible light spectrum range much more efficiently than the NiO-doped one. It is concluded that the nanostructured photoelectrochemical fuel cell can generate electricity and clean fuel by decomposing hazardous materials under sunlight.« less
Establishing a Disruptive New Capability for NASA to Fly UAV's into Hazardous Conditions
NASA Technical Reports Server (NTRS)
Ely, Jay; Nguyen, Truong; Wilson, Jennifer; Brown, Robert; Laughter, Sean; Teets, Ed; Parker, Allen; Chan, Patrick Hon Man; Richards, Lance
2015-01-01
A 2015 NASA Aeronautics Mission "Seedling" Proposal is described for a Severe-Environment UAV (SE-UAV) that can perform in-situ measurements in hazardous atmospheric conditions like lightning, volcanic ash and radiation. Specifically, this paper describes the design of a proof-of-concept vehicle and measurement system that can survive lightning attachment during flight operations into thunderstorms. Elements from three NASA centers draw together for the SE-UAV concept. 1) The NASA KSC Genesis UAV was developed in collaboration with the DARPA Nimbus program to measure electric field and X-rays present within thunderstorms. 2) A novel NASA LaRC fiber-optic sensor uses Faraday-effect polarization rotation to measure total lightning electric current on an air vehicle fuselage. 3) NASA AFRC's state-of-the-art Fiber Optics and Systems Integration Laboratory is envisioned to transition the Faraday system to a compact, light-weight, all-fiber design. The SE-UAV will provide in-flight lightning electric-current return stroke and recoil leader data, and serve as a platform for development of emerging sensors and new missions into hazardous environments. NASA's Aeronautics and Science Missions are interested in a capability to perform in-situ volcanic plume measurements and long-endurance UAV operations in various weather conditions. (Figure 1 shows an artist concept of a SE-UAV flying near a volcano.) This paper concludes with an overview of the NASA Aeronautics Strategic Vision, Programs, and how a SE-UAV is envisioned to impact them. The SE-UAV concept leverages high-value legacy research products into a new capability for NASA to fly a pathfinder UAV into hazardous conditions, and is presented in the SPIE DSS venue to explore teaming, collaboration and advocacy opportunities outside NASA.
Establishing a disruptive new capability for NASA to fly UAV's into hazardous conditions
NASA Astrophysics Data System (ADS)
Ely, Jay; Nguyen, Truong; Wilson, Jennifer; Brown, Robert; Laughter, Sean; Teets, Ed; Parker, Allen; Chan, Hon M.; Richards, Lance
2015-05-01
A 2015 NASA Aeronautics Mission "Seedling" Proposal is described for a Severe-Environment UAV (SE-UAV) that can perform in-situ measurements in hazardous atmospheric conditions like lightning, volcanic ash and radiation. Specifically, this paper describes the design of a proof-of-concept vehicle and measurement system that can survive lightning attachment during flight operations into thunderstorms. Elements from three NASA centers draw together for the SE-UAV concept. 1) The NASA KSC Genesis UAV was developed in collaboration with the DARPA Nimbus program to measure electric field and X-rays present within thunderstorms. 2) A novel NASA LaRC fiber-optic sensor uses Faraday-effect polarization rotation to measure total lightning electric current on an air vehicle fuselage. 3) NASA AFRC's state-of-the-art Fiber Optics and Systems Integration Laboratory is envisioned to transition the Faraday system to a compact, light-weight, all-fiber design. The SE-UAV will provide in-flight lightning electric-current return stroke and recoil leader data, and serve as a platform for development of emerging sensors and new missions into hazardous environments. NASA's Aeronautics and Science Missions are interested in a capability to perform in-situ volcanic plume measurements and long-endurance UAV operations in various weather conditions. (Figure 1 shows an artist concept of a SE-UAV flying near a volcano.) This paper concludes with an overview of the NASA Aeronautics Strategic Vision, Programs, and how a SE-UAV is envisioned to impact them. The SE-UAV concept leverages high-value legacy research products into a new capability for NASA to fly a pathfinder UAV into hazardous conditions, and is presented in the SPIE DSS venue to explore teaming, collaboration and advocacy opportunities outside NASA.
Mechanisms, predictors, and trends of electrical failure of Riata leads.
Cheung, Jim W; Al-Kazaz, Mohamed; Thomas, George; Liu, Christopher F; Ip, James E; Bender, Seth R; Siddiqi, Faisal K; Markowitz, Steven M; Lerman, Bruce B
2013-10-01
Riata and Riata ST implantable cardioverter-defibrillator leads have been shown to be prone to structural and electrical failure. To determine predictors, mechanisms, and temporal patterns of Riata/ST lead electrical failure. All 314 patients who underwent Riata/ST lead implantation at our institution with greater than or equal to 90 days of follow-up were studied. The Kaplan-Meier analysis of lead survival was performed. Results from the returned product analysis of explanted leads with electrical lead failure were recorded. During a median follow-up of 4.1 years, the Riata lead electrical failure rate was 6.6%. The rate of externalized conductors among failed leads was 57%. The engineering analysis of 10 explanted leads revealed 5 (50%) leads with electrical failure owing to breach of ethylene tetrafluoroethylene conductor coating. Female gender (hazard ratio 2.7; 95% confidence interval 1.1-6.7; P = .04) and age (hazard ratio 0.95; 95% confidence interval 0.92-0.97; P < .001) were multivariate predictors of lead failure. By using log-log analysis, we noted that the rate of Riata lead failure initially increased exponentially with a power of 2.1 but leads surviving past 4 years had a linear pattern of lead failure with a power of 1.0. Younger age and female gender are independent predictors of Riata lead failure. Loss of integrity of conductor cables with ethylene tetrafluoroethylene coating is an important mode of electrical failure of the Riata lead. Further study of Riata lead failure trends is warranted to guide lead management. © 2013 Heart Rhythm Society. All rights reserved.
40 CFR 267.115 - After I stop operating, how long until I must close?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...? (a) Within 90 days after the final volume of hazardous waste is sent to a unit, you must treat or remove from the unit all hazardous wastes following the approved closure plan. (b) You must complete...
40 CFR 267.115 - After I stop operating, how long until I must close?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...? (a) Within 90 days after the final volume of hazardous waste is sent to a unit, you must treat or remove from the unit all hazardous wastes following the approved closure plan. (b) You must complete...
40 CFR 267.115 - After I stop operating, how long until I must close?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...? (a) Within 90 days after the final volume of hazardous waste is sent to a unit, you must treat or remove from the unit all hazardous wastes following the approved closure plan. (b) You must complete...
The Sixteenth Annual Research Symposium on Remedial Action, Treatment and Disposal of Hazardous Waste was held in Cincinnati, Ohio, April 3-5, 1990. he purpose of this Symposium was to present the latest significant research findings from ongoing and recently completed projects f...
Enhanced control & sensing for the REMOTEC ANDROS Mk VI robot. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spelt, P.F.; Harvey, H.W.
1997-08-01
This Cooperative Research and Development Agreement (CRADA) between Lockheed Marietta Energy Systems, Inc., and REMOTEC, Inc., explored methods of providing operator feedback for various work actions of the ANDROS Mk VI teleoperated robot. In a hazardous environment, an extremely heavy workload seriously degrades the productivity of teleoperated robot operators. This CRADA involved the addition of computer power to the robot along with a variety of sensors and encoders to provide information about the robot`s performance in and relationship to its environment. Software was developed to integrate the sensor and encoder information and provide control input to the robot. ANDROS Mkmore » VI robots are presently used by numerous electric utilities to perform tasks in reactors where substantial exposure to radiation exists, as well as in a variety of other hazardous environments. Further, this platform has potential for use in a number of environmental restoration tasks, such as site survey and detection of hazardous waste materials. The addition of sensors and encoders serves to make the robot easier to manage and permits tasks to be done more safely and inexpensively (due to time saved in the completion of complex remote tasks). Prior research on the automation of mobile platforms with manipulators at Oak Ridge National Laboratory`s Center for Engineering Systems Advanced Research (CESAR, B&R code KC0401030) Laboratory, a BES-supported facility, indicated that this type of enhancement is effective. This CRADA provided such enhancements to a successful working teleoperated robot for the first time. Performance of this CRADA used the CESAR laboratory facilities and expertise developed under BES funding.« less
Safety on North Carolina and Kentucky trout farms.
Ogunsanya, T J; Durborow, R M; Myers, M L; Cole, H P; Thompson, S L
2011-01-01
The objective of this study was to identify and describe work-related safety hazards, injuries, and near-injury events (close calls) that occurred on trout farms in North Carolina and Kentucky. An interview instrument was used to collect information on occupational hazards, injuries, and near-injury events that resulted from work-related activities. Trout farmers reported occupational hazards including falling live tank lids, slippery surfaces on hauling trucks, lifting strains, falls from raceway walls and walkways, needlesticks while vaccinating fish, allergies, hypothermia/drowning, falls from cranes, chemical exposure, fire/explosions related to oxygen exposure, and electrical contact with overhead power lines. This study also reports solutions suggested by farm safety researchers or used by farmers to prevent the safety hazards found on trout farms.
Seismic Landslide Hazard for the City of Berkeley, California
Miles, Scott B.; Keefer, David K.
2001-01-01
This map describes the possible hazard from earthquake-induced landslides for the city of Berkeley, CA. The hazard depicted by this map was modeled for a scenario corresponding to an M=7.1 earthquake on the Hayward, CA fault. This scenario magnitude is associated with complete rupture of the northern and southern segments of the Hayward fault, an event that has an estimated return period of about 500 years. The modeled hazard also corresponds to completely saturated ground-water conditions resulting from an extreme storm event or series of storm events. This combination of earthquake and ground-water scenarios represents a particularly severe state of hazard for earthquake-induced landslides. For dry ground-water conditions, overall hazard will be less, while relative patterns of hazard are likely to change. Purpose: The map is intended as a tool for regional planning. Any site-specific planning or analysis should be undertaken with the assistance of a qualified geotechnical engineer. This hazard map should not be used as a substitute to the State of California Seismic Hazard Zones map for the same area. (See California Department of Conservation, Division of Mines and Geology, 1999). As previously noted for maps of this type by Wieczorek and others (1985), this map should not be used as a basis to determine the absolute risk from seismically triggered landslides at any locality, as the sole justification for zoning or rezoning any parcel, for detailed design of any lifeline, for site-specific hazard-reduction planning, or for setting or modifying insurance rates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riddle, F. J.
2003-06-26
The Automated Hazard Analysis (AHA) application is a software tool used to conduct job hazard screening and analysis of tasks to be performed in Savannah River Site facilities. The AHA application provides a systematic approach to the assessment of safety and environmental hazards associated with specific tasks, and the identification of controls regulations, and other requirements needed to perform those tasks safely. AHA is to be integrated into existing Savannah River site work control and job hazard analysis processes. Utilization of AHA will improve the consistency and completeness of hazard screening and analysis, and increase the effectiveness of the workmore » planning process.« less
Electrical Tomography for seismic hazard monitoring: state-of-the-art and future challenges.
NASA Astrophysics Data System (ADS)
Lapenna, Vincenzo; Piscitelli, Sabatino
2010-05-01
The Self-Potential (passive) and DC resistivity (active) methods have been considered for a long period as ancillary and/or secondary tools in geophysical exploration, simplified procedures for data processing and purely qualitative techniques for data inversion were the main drawbacks. Recently, innovative algorithms for tomographic data inversion, new models for describing the electrokinetic phenomena associated to the subsurface fluid migration and modern technologies for the field surveying have rapidly transformed these geoelectrical methods in powerful tools for geo-hazard monitoring. These technological and methodological improvements disclose the way for a wide spectra of interesting and challenging applications: mapping of the water content in landslide bodies; identification of fluid and gas emissions in volcanic areas; search of earthquake precursors. In this work we briefly resume the current start-of-the-art and analyse the new applications of the Electrical Tomography in the seismic hazard monitoring. An overview of the more interesting results obtained in different worldwide areas (i.e. Mediterranean Basin, California, Japan) is presented and discussed. To-date, combining novel techniques for data inversion and new strategies for the field data acquisition is possible to obtain high-resolution electrical images of complex geological structures. One of the key challenges for the near-future will be the integration of active (DC resistivity) and passive (Self-Potential) measurements for obtaining 2D, 3D and 4D electrical tomographies able to follow the spatial and temporal dynamics of electrical parameters (i.e. resistivity, self-potential). This approach could reduce the ambiguities related to the interpretation of anomalous SP signals in seismic active areas and their applicability for short-term earthquake prediction. The resistivity imaging can be applied for illuminating the fault geometry, while the SP imaging is the key instrument for capturing the fingerprints of the electrokinetic phenomena potentially generated in focal regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohi, J M
1992-09-01
This report is the first of four volumes that identify and assess the environmental, health, and safety issues involved in using sodium-sulfur (Na/S) battery technology as the energy source in electric and hybrid vehicles that may affect the commercialization of Na/S batteries. This and the other reports on recycling, shipping, and vehicle safety are intended to help the Electric and Hybrid Propulsion Division of the Office of Transportation Technologies in the US Department of Energy (DOE/EHP) determine the direction of its research, development, and demonstration (RD&D) program for Na/S battery technology. The reports review the status of Na/S battery RD&Dmore » and identify potential hazards and risks that may require additional research or that may affect the design and use of Na/S batteries. This volume covers cell design and engineering as the basis of safety for Na/S batteries and describes and assesses the potential chemical, electrical, and thermal hazards and risks of Na/S cells and batteries as well as the RD&D performed, under way, or to address these hazards and risks. The report is based on a review of the literature and on discussions with experts at DOE, national laboratories and agencies, universities, and private industry. Subsequent volumes will address environmental, health, and safety issues involved in shipping cells and batteries, using batteries to propel electric vehicles, and recycling and disposing of spent batteries. The remainder of this volume is divided into two major sections on safety at the cell and battery levels. The section on Na/S cells describes major component and potential failure modes, design, life testing and failure testing, thermal cycling, and the safety status of Na/S cells. The section on batteries describes battery design, testing, and safety status. Additional EH&S information on Na/S batteries is provided in the appendices.« less
Hodnik, Nejc; Baldizzone, Claudio; Polymeros, George; Geiger, Simon; Grote, Jan-Philipp; Cherevko, Serhiy; Mingers, Andrea; Zeradjanin, Aleksandar; Mayrhofer, Karl J. J.
2016-01-01
The recycling of precious metals, for example, platinum, is an essential aspect of sustainability for the modern industry and energy sectors. However, due to its resistance to corrosion, platinum-leaching techniques rely on high reagent consumption and hazardous processes, for example, boiling aqua regia; a mixture of concentrated nitric and hydrochloric acid. Here we demonstrate that complete dissolution of metallic platinum can be achieved by induced surface potential alteration, an ‘electrode-less' process utilizing alternatively oxidative and reductive gases. This concept for platinum recycling exploits the so-called transient dissolution mechanism, triggered by a repetitive change in platinum surface oxidation state, without using any external electric current or electrodes. The effective performance in non-toxic low-concentrated acid and at room temperature is a strong benefit of this approach, potentially rendering recycling of industrial catalysts, including but not limited to platinum-based systems, more sustainable. PMID:27767178
Neutralization of cement-asbestos waste by melting in an arc-resistance furnace.
Witek, Jerzy; Kusiorowski, Robert
2017-11-01
The paper presents the results of research on asbestos waste disposal by the melting process. The tests were carried out in a laboratory arc-resistance electric furnace. The obtained results showed that the fibrous structure of asbestos contained in cement-asbestos waste was completely destroyed. This led to the formation of new mineral phases without dangerous properties. The melting test was conducted on raw cement-asbestos samples without any additives and with a content of mineral compounds, the aim of which was to support the melting process. The additives were selected among others on the basis of the computer simulation results carried out using FactSage database computing system. The research results indicate that the melting process of asbestos wastes is a potential and interesting method of neutralizing hazardous asbestos waste, which allows for further treatment and material recycling. Copyright © 2017 Elsevier Ltd. All rights reserved.
Environmental management of industrial hazardous wastes in India.
Dutta, Shantanu K; Upadhyay, V P; Sridharan, U
2006-04-01
Hazardous wastes are considered highly toxic and therefore disposal of such wastes needs proper attention so as to reduce possible environmental hazards. Industrial growth has resulted in generation of huge volume of hazardous wastes in the country. In addition to this, hazardous wastes sometimes get imported mainly from the western countries for re-processing or recycling. Inventorisation of hazardous wastes generating units in the country is not yet completed. Scientific disposal of hazardous wastes has become a major environmental issue in India. Hazardous Wastes (Management and Handling) Rules, 1989 have been framed by the Central Government and amended in 2000 and 2003 to deal with the hazardous wastes related environmental problems that may arise in the near future. This paper gives details about the hazardous wastes management in India. Health effects of the selected hazardous substances are also discussed in the paper.
Identification of elements at risk for a credible tsunami event for Istanbul
NASA Astrophysics Data System (ADS)
Hancilar, U.
2012-01-01
Physical and social elements at risk are identified for a credible tsunami event for Istanbul. For this purpose, inundation maps resulting from probabilistic tsunami hazard analysis for a 10% probability of exceedance in 50 yr are utilised in combination with the geo-coded inventories of building stock, lifeline systems and demographic data. The built environment on Istanbul's shorelines that is exposed to tsunami inundation comprises residential, commercial, industrial, public (governmental/municipal, schools, hospitals, sports and religious), infrastructure (car parks, garages, fuel stations, electricity transformer buildings) and military buildings, as well as piers and ports, gas tanks and stations and other urban elements (e.g., recreational facilities). Along the Marmara Sea shore, Tuzla shipyards and important port and petrochemical facilities at Ambarlı are expected to be exposed to tsunami hazard. Significant lifeline systems of the city of Istanbul such as natural gas, electricity, telecommunication and sanitary and waste-water transmission, are also under the threat of tsunamis. In terms of social risk, it is estimated that there are about 32 000 inhabitants exposed to tsunami hazard.
Canister Storage Building (CSB) Hazard Analysis Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
POWERS, T.B.
2000-03-16
This report describes the methodology used in conducting the Canister Storage Building (CSB) Hazard Analysis to support the final CSB Safety Analysis Report and documents the results. This report describes the methodology used in conducting the Canister Storage Building (CSB) hazard analysis to support the CSB final safety analysis report (FSAR) and documents the results. The hazard analysis process identified hazardous conditions and material-at-risk, determined causes for potential accidents, identified preventive and mitigative features, and qualitatively estimated the frequencies and consequences of specific occurrences. The hazard analysis was performed by a team of cognizant CSB operations and design personnel, safetymore » analysts familiar with the CSB, and technical experts in specialty areas. The material included in this report documents the final state of a nearly two-year long process. Attachment A provides two lists of hazard analysis team members and describes the background and experience of each. The first list is a complete list of the hazard analysis team members that have been involved over the two-year long process. The second list is a subset of the first list and consists of those hazard analysis team members that reviewed and agreed to the final hazard analysis documentation. The material included in this report documents the final state of a nearly two-year long process involving formal facilitated group sessions and independent hazard and accident analysis work. The hazard analysis process led to the selection of candidate accidents for further quantitative analysis. New information relative to the hazards, discovered during the accident analysis, was incorporated into the hazard analysis data in order to compile a complete profile of facility hazards. Through this process, the results of the hazard and accident analyses led directly to the identification of safety structures, systems, and components, technical safety requirements, and other controls required to protect the public, workers, and environment.« less
NASA Technical Reports Server (NTRS)
Smiles, Michael D.; Blythe, Michael P.; Bejmuk, Bohdan; Currie, Nancy J.; Doremus, Robert C.; Franzo, Jennifer C.; Gordon, Mark W.; Johnson, Tracy D.; Kowaleski, Mark M.; Laube, Jeffrey R.
2015-01-01
The Chief Engineer of the Exploration Systems Development (ESD) Office requested that the NASA Engineering and Safety Center (NESC) perform an independent assessment of the ESD's integrated hazard development process. The focus of the assessment was to review the integrated hazard analysis (IHA) process and identify any gaps/improvements in the process (e.g., missed causes, cause tree completeness, missed hazards). This document contains the outcome of the NESC assessment.
NASA Technical Reports Server (NTRS)
Smiles, Michael D.; Blythe, Michael P.; Bejmuk, Bohdan; Currie, Nancy J.; Doremus, Robert C.; Franzo, Jennifer C.; Gordon, Mark W.; Johnson, Tracy D.; Kowaleski, Mark M.; Laube, Jeffrey R.
2015-01-01
The Chief Engineer of the Exploration Systems Development (ESD) Office requested that the NASA Engineering and Safety Center (NESC) perform an independent assessment of the ESD's integrated hazard development process. The focus of the assessment was to review the integrated hazard analysis (IHA) process and identify any gaps/improvements in the process (e.g. missed causes, cause tree completeness, missed hazards). This document contains the outcome of the NESC assessment.
Assessment and Control of Spacecraft Charging Risks on the International Space Station
NASA Technical Reports Server (NTRS)
Koontz, Steve; Valentine, Mark; Keeping, Thomas; Edeen, Marybeth; Spetch, William; Dalton, Penni
2004-01-01
The International Space Station (ISS) operates in the F2 region of Earth's ionosphere, orbiting at altitudes ranging from 350 to 450 km at an inclination of 51.6 degrees. The relatively dense, cool F2 ionospheric plasma suppresses surface charging processes much of the time, and the flux of relativistic electrons is low enough to preclude deep dielectric charging processes. The most important spacecraft charging processes in the ISS orbital environment are: 1) ISS electrical power system interactions with the F2 plasma, 2) magnetic induction processes resulting from flight through the geomagnetic field and, 3) charging processes that result from interaction with auroral electrons at high latitude. Recently, the continuing review and evaluation of putative ISS charging hazards required by the ISS Program Office revealed that ISS charging could produce an electrical shock hazard to the ISS crew during extravehicular activity (EVA). ISS charging risks are being evaluated in an ongoing measurement and analysis campaign. The results of ISS charging measurements are combined with a recently developed model of ISS charging (the Plasma Interaction Model) and an exhaustive analysis of historical ionospheric variability data (ISS Ionospheric Specification) to evaluate ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA combines estimates of the frequency of occurrence and severity of the charging hazards with estimates of the reliability of various hazard controls systems, as required by NASA s safety and risk management programs, to enable design and selection of a hazard control approach that minimizes overall programmatic and personnel risk. The PRA provides a quantitative methodology for incorporating the results of the ISS charging measurement and analysis campaigns into the necessary hazard reports, EVA procedures, and ISS flight rules required for operating ISS in a safe and productive manner.
Levy, Matthew; Jenkins, J Lee; Seaman, Kevin
2014-01-01
Portable generators are commonly used during electrical service interruptions that occur following large storms such as hurricanes. Nearly all portable generators use carbon based fuels and produce deadly carbon monoxide gas. Despite universal warnings to operate these generators outside only, the improper placement of generators makes these devices the leading cause of engine related carbon monoxide deaths in the United States. The medical literature reports many cases of Carbon Monoxide (CO) toxicity associated with generator use following hurricanes and other weather events. This paper describes how Howard County, Maryland Fire and Rescue (HCFR) Services implemented a public education program that focused on prevention of Carbon Monoxide poisoning from portable generator use in the wake of events where electrical service interruptions occurred or had the potential to occur. A major challenge faced was communication with those members of the population who were almost completely dependent upon electronic and wireless technologies and were without redundancies. HCFR utilized several tactics to overcome this challenge including helicopter based surveillance and the use of geocoded information from the electrical service provider to identify outage areas. Once outage areas were identified, HCFR personnel conducted a door-to-door canvasing of effected communities, assessing for hazards and distributing information flyers about the dangers of generator use. This effort represents one of the first reported examples of a community-based endeavor by a fire department to provide proactive interventions designed to prevent carbon monoxide illness. PMID:24596660
Update on Alternatives for Cadmium Coatings on Military Electrical Connectors
2010-03-01
Update on Alternatives for Cadmium Coatings on Military Electrical Connectors The metal finishing industry hasbeen impacted by numerous reg- ulatory...government agen- cies to reduce the quantity of toxic and hazardous chemicals and materi- als acquired, used, or disposed. Cadmium and hexavalent...of cadmium and hexavalent chromium in ground vehicles and related systems. The National Defense Center for Energy and Environment (NDCEE), operated
Significant Revisions to OSHA 29 CFR 1910.269.
Neitzel, Dennis K
2015-06-01
The updated OSHA 29 CFR 1910.269 requirements are significant for assisting employers in their efforts to protect their employees from electrical hazards. In addition, OSHA based these revisions on the latest consensus standards and improvements in electrical safety technology. Together, the updated regulation creates a unified and up-to-date set of requirements to help employers more effectively establish safe work practices to protect their workers.
Teaching Electricity and Engineering with LEDs
ERIC Educational Resources Information Center
Johnstone, Christopher
2014-01-01
When learning about electricity, students are typically asked to complete a simple circuit involving a battery, wire, and lightbulb. This activity can be enhanced by adding discussion and discourse and can take on a unique final form in the case of "The Friendship Detector." In such electrical circuit activities, the completed circuit is…
Self-contained clothing system provides protection against hazardous environments
NASA Technical Reports Server (NTRS)
1966-01-01
Self-contained clothing system protects personnel against hazardous environments. The clothing has an environmental control system and a complete protection envelope consisting of an outer garment, inner garment, underwear, boots, gloves, and helmet.
Safety in the SEM laboratory--1981 update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bance, G.N.; Barber, V.C.; Sholdice, J.A.
1981-01-01
The article reviews recent information on hazards as they relate to safety in SEM laboratories. The first section lists the safety equipment that should be available in a SEM laboratory. Flammable and combustible liquids are discussed, and particular warnings are given concerning the fire and explosion risks associated with diethyl ether and diisopropyl ether. The possible hazards associated with electrical equipment, and the risk of X-ray emissions from EM's are briefly outlined. The hazards associated with acute and chronic toxicity of chemicals used in the EM laboratory are discussed. The need to reduce exposure to a growing list of recognizablemore » hazardous chemicals is emphasized. This reduction can be accomplished by more extensive use of functioning fume hoods, and the use of more appropriate and effective protective gloves. Allergies and the hazards of dangerous pathogens in the SEM laboratory are discussed. The explosion and other hazards associated with cryogens, vacuum evaporators, critical point dryers, and compressed gas cylinders are emphasized.« less
GRC Payload Hazard Assessment: Supporting the STS-107 Accident Investigation
NASA Technical Reports Server (NTRS)
Schoren, William R.; Zampino, Edward J.
2004-01-01
A hazard assessment was conducted on the GRC managed payloads in support of a NASA Headquarters Code Q request to examine STS-107 payloads and determine if they were credible contributors to the Columbia accident. This assessment utilized each payload's Final Flight Safety Data Package for hazard identification. An applicability assessment was performed and most of the hazards were eliminated because they dealt with payload operations or crew interactions. A Fault Tree was developed for all the hazards deemed applicable and the safety verification documentation was reviewed for these applicable hazards. At the completion of this hazard assessment, it was concluded that none of the GRC managed payloads were credible contributors to the Columbia accident.
A one-dimensional model of solid-earth electrical resistivity beneath Florida
Blum, Cletus; Love, Jeffrey J.; Pedrie, Kolby; Bedrosian, Paul A.; Rigler, E. Joshua
2015-11-19
An estimated one-dimensional layered model of electrical resistivity beneath Florida was developed from published geological and geophysical information. The resistivity of each layer is represented by plausible upper and lower bounds as well as a geometric mean resistivity. Corresponding impedance transfer functions, Schmucker-Weidelt transfer functions, apparent resistivity, and phase responses are calculated for inducing geomagnetic frequencies ranging from 10−5 to 100 hertz. The resulting one-dimensional model and response functions can be used to make general estimates of time-varying electric fields associated with geomagnetic storms such as might represent induction hazards for electric-power grid operation. The plausible upper- and lower-bound resistivity structures show the uncertainty, giving a wide range of plausible time-varying electric fields.
Daniel, Claus; Li, Jianlin
2018-01-16
At the DOE Battery Manufacturing R&D Facility, researchers are partnering with industry to increase energy density, reduce costs and hazardous materials, and improve the manufacturing process for batteries used in electric vehicles and other applications.
Ergonomics: The Forgotten Variable.
ERIC Educational Resources Information Center
Fitterman, L. Jeffrey
1998-01-01
Defines ergonomics and discusses design and environmental considerations. Suggests work-space requirements for: tables, chairs, monitor height, ambient noise and light, electricity, and environmental hazards. Includes sources for additional information related to ergonomic design. (AEF)
Geological hazard monitoring system in Georgia
NASA Astrophysics Data System (ADS)
Gaprindashvili, George
2017-04-01
Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.
NASA Astrophysics Data System (ADS)
Fargier, Yannick; Dore, Ludovic; Antoine, Raphael; Palma Lopes, Sérgio; Fauchard, Cyrille
2016-04-01
The extraction of subsurface materials is a key element for the economy of a nation. However, natural degradation of underground quarries is a major issue from an economic and public safety point of view. Consequently, the quarries stakeholders require relevant tools to define hazards associated to these structures. Safety assessment methods of underground quarries are recent and mainly based on rock physical properties. This kind of method leads to a certain homogeneity assumption of pillar internal properties that can cause an underestimation of the risk. Electrical Resistivity Imaging (ERI) is a widely used method that possesses two advantages to overcome this limitation. The first is to provide a qualitative understanding for the detection and monitoring of anomalies in the pillar body (e.g. faults). The second is to provide a quantitative description of the electrical resistivity distribution inside the pillar. This quantitative description can be interpreted with constitutive laws to help decision support (water content decreases the mechanical resistance of a chalk). However, conventional 2D and 3D Imaging techniques are usually applied to flat surface surveys or to surfaces with moderate topography. A 3D inversion of more complex media (case of the pillar) requires a full consideration of the geometry that was never taken into account before. The Photogrammetric technique presents a cost effective solution to obtain an accurate description of the external geometry of a complex media. However, this method has never been fully coupled with a geophysical method to enhance/improve the inversion process. Consequently we developed a complete procedure showing that photogrammetric and ERI tools can be efficiently combined to assess a complex 3D structure. This procedure includes in a first part a photogrammetric survey, a processing stage with an open source software and a post-processing stage finalizing a 3D surface model. The second part necessitates the production of a complete 3D mesh of the previous surface model to operate some forward modelization of the geo-electrical problem. To solve the inverse problem and obtain a 3D resistivity distribution we use a double grid method associated with a regularized Gauss-Newton inversion scheme. We applied this procedure to a synthetic case to demonstrate the impact of the geometry on the inversion result. This study shows that geometrical information in between electrodes are necessary to reconstruct finely the "true model". Finally, we apply the methodology to a real underground quarry pillar, implying one photogrammetric survey and three ERI surveys. The results show that the procedure can greatly improve the reconstruction and avoid some artifacts due to strong geometry variations.
NASA Technical Reports Server (NTRS)
Cribb, H. E.
1970-01-01
Two-way wireless voice communications system is automatic, provides freedom of movement, allows for complete awareness of the environment, and does not present any additional hazards such as activation of electromagnetic sensitive devices.
Quality assurance audits of medical surveillance programs for hazardous waste workers.
Udasin, I G; Buckler, G; Gochfeld, M
1991-11-01
The Occupational Safety and Health Administration (OSHA) Hazardous Waste Operations and Emergency Response Regulation (29 CFR 1910.120) requires medical surveillance examinations for hazardous waste workers. We investigated the consistency and appropriateness of the services provided under OSHA 29 CFR 1910.120 as part of a quality control audit. Our study revealed that in most cases the required paperwork including fitness for duty and restrictions or limitations was completed. However, it is also apparent that many of the components of a complete occupational history were not performed. Spirometric examinations often were performed incorrectly. Documentation of baseline tests was not uniformly done, nor were patients always informed of the findings of their examinations. Our study indicated there may be a lack of education, training, and experience of occupational health providers. This suggests that further efforts should be made to educate physicians and nurses providing medical surveillance and other services to hazardous waste workers.
Health hazard evaluation report HETA 92-064-2222, Ohio Valley Litho Color, Inc. , Florence, Kentucky
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moss, C.E.; Burr, G.
1992-05-01
In response to a confidential request from a worker at Ohio Valley Litho Color, Inc. (SIC-2652) in Florence, Kentucky, an evaluation was made of possible exposure to electrical currents during the operation of an industrial papercutter. The company used industrial papercutters to prepare various types of advertising material for their clients. An operator of the papercutters had been diagnosed with a brain tumor. Measurements indicated that operators of the equipment had electrical currents of 9.7 to 160 microamperes passing through their bodies. There do not appear to be any standards related to exposure to currents of this magnitude passing throughmore » the body. The authors conclude that no electrocution or electrical burn hazard existed at the time of the survey. The lack of data to indicate the outcome of chronic exposure to low levels of currents passing through the body over a period of several years makes it impossible to rule out a connection between this exposure and chronic diseases such as brain tumors or cancers. The authors recommend that efforts be made to eliminate this exposure.« less
Dependability: a challenge for electrical medical implants.
Cathébras, Guy; Le Floch, Fanny; Bernard, Serge; Soulier, Fabien
2010-01-01
Functional Electrical Stimulation (FES) is an attractive solution to restore some lost or failing physiological functions. Obviously, the FES system may be hazardous for patient and the reliability and dependability of the system must be maximal. Unfortunately, the present context, where the associated systems are more and more complex and their development needs very cross-disciplinary experts, is not favorable to safety. Moreover, the direct adaptation of the existing dependability techniques from domains such as space or automotive is not suitable. Firstly, this paper proposes a strategy for risk management at system level for FES medical implant. The idea is to give a uniform framework where all possible hazards are highlighted and associated consequences are minimized. Then, the paper focuses on critical parts of the FES system: analog micro-circuit which generates the electrical signal to electrode. As this micro-circuit is the closest to the human tissue, any failure might involve very critical consequences for the patient. We propose a concurrent top-down and bottom-up approach where the critical elements are highlighted and an extended risk analysis is performed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-04
... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Residential Lead- Based Paint...'') under the Residential Lead-Based Paint Hazard Reduction Act, 42 U.S.C. 4851 et seq. (``Lead Hazard... of the disclosures or to complete one or more of the disclosure activities required by the Lead...
Mortality of persons resident in the vicinity of electricity transmission facilities.
McDowall, M. E.
1986-01-01
Several studies have raised the possibility that exposure to electrical and/or magnetic fields may be injurious to health in particular by the promotion or initiation of cancer. To investigate whether the electricity transmission system presents a long term hazard to public health, the mortality of nearly 8,000 persons, identified as living in the vicinity of electrical transmission facilities at the time of the 1971 Population Census, has been followed to the end of 1983. All identified transmission installations within pre-defined areas were included in the study with the result that the greater part of the study group were believed to be resident near relatively low voltage sub-stations. Overall mortality was lower than expected and no evidence of major health hazards emerged. The only statistically significant excess mortality was for lung cancer (in women overall, and in persons living closest to the installations); this result is difficult to interpret in the absence of smoking data, and is not supported by other evidence but does not appear to be due to the social class distribution of the study group. The study did not support previously reported associations of exposure to electro-magnetic fields with acute myeloid leukaemia, other lymphatic cancers and suicide. PMID:3456788
14 CFR 23.1163 - Powerplant accessories.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Electrical equipment subject to arcing or sparking must be installed to minimize the probability of contact... or more than 6 kilowatts must be designed and installed to minimize the probability of a fire hazard...
42 CFR 483.364 - Monitoring of the resident in and immediately after seclusion.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under Age 21 § 483... potentially hazardous conditions such as unprotected light fixtures and electrical outlets. (c) If the...
42 CFR 483.364 - Monitoring of the resident in and immediately after seclusion.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under Age 21 § 483... potentially hazardous conditions such as unprotected light fixtures and electrical outlets. (c) If the...
42 CFR 483.364 - Monitoring of the resident in and immediately after seclusion.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under Age 21 § 483... potentially hazardous conditions such as unprotected light fixtures and electrical outlets. (c) If the...
42 CFR 483.364 - Monitoring of the resident in and immediately after seclusion.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under Age 21 § 483... potentially hazardous conditions such as unprotected light fixtures and electrical outlets. (c) If the...
“Capacitive Sensor” to Measure Flow Electrification and Prevent Electrostatic Hazards
Paillat, Thierry; Touchard, Gerard; Bertrand, Yves
2012-01-01
At a solid/liquid interface, physico-chemical phenomena occur that lead to the separation of electrical charges, establishing a zone called electrical double layer. The convection of one part of these charges by the liquid flow is the cause of the flow electrification phenomenon which is suspected of being responsible of incidents in the industry. The P' Institute of Poitiers University and CNRS has developed an original sensor called “capacitive sensor” that allows the characterization of the mechanisms involved in the generation, accumulation and transfer of charges. As an example, this sensor included in the design of high power transformers, could easily show the evolution of electrostatic charge generation developed during the operating time of the transformer and, therefore, point out the operations leading to electrostatic hazards and, then, monitor the transformer to prevent such risks. PMID:23202162
NASA Technical Reports Server (NTRS)
Hamilton, Douglas; Kramer, Leonard; Mikatarian, Ron; Polk, James; Duncan, Michael; Koontz, Steven
2010-01-01
The models predict that, for low voltage exposures in the space suit, physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work with Naval Health Research Center Detachment Directed Energy Bio-effects Laboratory is being proposed to analyze additional current paths across the human torso and upper limbs. These models may need to be verified with human studies.
Pulsed Heterodyne CO2 Laser/Scanner System. Volume 1. Assembly Report.
1983-06-01
rack #2 houses the switches and variacs controlling the DC power rectifier, which is in an oil tank under the optical bench. These two units are...or fire hazards (due to oil filled electrical equipments). This section, however, addresses only the four main hazards. Ozone The atmospheric pressure...ventilation of the exhaust of the 002 lasers is essencial to the safe operation of this system. High Voltage The system consists of 40 separate
On the hazard of quiet vehicles to pedestrians and drivers.
Wogalter, Michael S; Lim, Raymond W; Nyeste, Patrick G
2014-09-01
The need to produce more efficient and less polluting vehicles has encouraged mass production of alternative energy vehicles, such as hybrid and electric cars. Many of these vehicles are capable of very quiet operation. While reducing noise pollution is desirable, quieter vehicles could negatively affect pedestrian safety because of reduced sound cues compared to louder internal combustion engines. Three studies were performed to investigate people's concern about this issue. In Study 1, a questionnaire completed by 378 people showed substantial positive interest in quiet hybrid and electric cars. However, they also indicated concern about the reduced auditory cues of quiet vehicles. In Study 2, 316 participants rated 14 sounds that could be potentially added to quiet alternative-energy vehicles. The data showed that participants did not want annoying sounds, but preferred adding "engine" and "hum" sounds relative to other types of sounds. In Study 3, 24 persons heard and rated 18 actual sounds within 6 categories that were added to a video of a hybrid vehicle driving by. The sounds most preferred were "engine" followed by "white noise" and "hum". Implications for adding sounds to facilitate pedestrians' detection of moving vehicles and for aiding drivers' awareness of speed are discussed. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Hazard Management Dealt by Safety Professionals in Colleges: The Impact of Individual Factors.
Wu, Tsung-Chih; Chen, Chi-Hsiang; Yi, Nai-Wen; Lu, Pei-Chen; Yu, Shan-Chi; Wang, Chien-Peng
2016-12-03
Identifying, evaluating, and controlling workplace hazards are important functions of safety professionals (SPs). The purpose of this study was to investigate the content and frequency of hazard management dealt by safety professionals in colleges. The authors also explored the effects of organizational factors/individual factors on SPs' perception of frequency of hazard management. The researchers conducted survey research to achieve the objective of this study. The researchers mailed questionnaires to 200 SPs in colleges after simple random sampling, then received a total of 144 valid responses (response rate = 72%). Exploratory factor analysis indicated that the hazard management scale (HMS) extracted five factors, including physical hazards, biological hazards, social and psychological hazards, ergonomic hazards, and chemical hazards. Moreover, the top 10 hazards that the survey results identified that safety professionals were most likely to deal with (in order of most to least frequent) were: organic solvents, illumination, other chemicals, machinery and equipment, fire and explosion, electricity, noise, specific chemicals, human error, and lifting/carrying. Finally, the results of one-way multivariate analysis of variance (MANOVA) indicated there were four individual factors that impacted the perceived frequency of hazard management which were of statistical and practical significance: job tenure in the college of employment, type of certification, gender, and overall job tenure. SPs within colleges and industries can now discuss plans revolving around these five areas instead of having to deal with all of the separate hazards.
Hazard Management Dealt by Safety Professionals in Colleges: The Impact of Individual Factors
Wu, Tsung-Chih; Chen, Chi-Hsiang; Yi, Nai-Wen; Lu, Pei-Chen; Yu, Shan-Chi; Wang, Chien-Peng
2016-01-01
Identifying, evaluating, and controlling workplace hazards are important functions of safety professionals (SPs). The purpose of this study was to investigate the content and frequency of hazard management dealt by safety professionals in colleges. The authors also explored the effects of organizational factors/individual factors on SPs’ perception of frequency of hazard management. The researchers conducted survey research to achieve the objective of this study. The researchers mailed questionnaires to 200 SPs in colleges after simple random sampling, then received a total of 144 valid responses (response rate = 72%). Exploratory factor analysis indicated that the hazard management scale (HMS) extracted five factors, including physical hazards, biological hazards, social and psychological hazards, ergonomic hazards, and chemical hazards. Moreover, the top 10 hazards that the survey results identified that safety professionals were most likely to deal with (in order of most to least frequent) were: organic solvents, illumination, other chemicals, machinery and equipment, fire and explosion, electricity, noise, specific chemicals, human error, and lifting/carrying. Finally, the results of one-way multivariate analysis of variance (MANOVA) indicated there were four individual factors that impacted the perceived frequency of hazard management which were of statistical and practical significance: job tenure in the college of employment, type of certification, gender, and overall job tenure. SPs within colleges and industries can now discuss plans revolving around these five areas instead of having to deal with all of the separate hazards. PMID:27918474
Fault tolerant vector control of induction motor drive
NASA Astrophysics Data System (ADS)
Odnokopylov, G.; Bragin, A.
2014-10-01
For electric composed of technical objects hazardous industries, such as nuclear, military, chemical, etc. an urgent task is to increase their resiliency and survivability. The construction principle of vector control system fault-tolerant asynchronous electric. Displaying recovery efficiency three-phase induction motor drive in emergency mode using two-phase vector control system. The process of formation of a simulation model of the asynchronous electric unbalance in emergency mode. When modeling used coordinate transformation, providing emergency operation electric unbalance work. The results of modeling transient phase loss motor stator. During a power failure phase induction motor cannot save circular rotating field in the air gap of the motor and ensure the restoration of its efficiency at rated torque and speed.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... Emission Standards for Hazardous Air Pollutants From Coal- and Oil-Fired Electric Utility Steam Generating...-Institutional, and Small Industrial-Commercial- Institutional Steam Generating Units Correction Proposed rule...
Spectrum Management and Electromagnetic Environmental Effects (E3) Business Process
2010-05-06
HAZARDS OF ELECTROMAGNETIC RADIATION TO ORDNANCE ( HERO ) SURVEY. XM11: IS THERE A CURRENT ELECTROMAGNETIC INTERFERENCE (EMI) SITE SURVEY. SM & EMI Navy...PERSONNEL (HERP) / FUEL (HERF) SURVEY. XM10: IS THERE A CURRENT HAZARDS OF ELECTROMAGNETIC RADIATION TO ORDNANCE ( HERO ) SURVEY. XM11...OF ALL KNOWN ELECTROMAGNETIC INTERFERENCE (EMI) FIXES INSTALLED ONE YEAR AFTER SURVEY COMPLETION. M05: OF ALL RADIATION HAZARDS
Santarelli, M; Barra, S; Sagnelli, F; Zitella, P
2012-11-01
The paper deals with the energy analysis and optimization of a complete biomass-to-electricity energy pathway, starting from raw biomass towards the production of renewable electricity. The first step (biomass-to-biogas) is based on a real pilot plant located in Environment Park S.p.A. (Torino, Italy) with three main steps ((1) impregnation; (2) steam explosion; (3) enzymatic hydrolysis), completed by a two-step anaerobic fermentation. In the second step (biogas-to-electricity), the paper considers two technologies: internal combustion engines and a stack of solid oxide fuel cells. First, the complete pathway has been modeled and validated through experimental data. After, the model has been used for an analysis and optimization of the complete thermo-chemical and biological process, with the objective function of maximization of the energy balance at minimum consumption. The comparison between ICE and SOFC shows the better performance of the integrated plants based on SOFC. Copyright © 2012 Elsevier Ltd. All rights reserved.
Enhanced control and sensing for the REMOTEC ANDROS Mk VI robot. CRADA final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spelt, P.F.; Harvey, H.W.
1998-08-01
This Cooperative Research and Development Agreement (CRADA) between Lockheed Martin Energy Systems, Inc., and REMOTEC, Inc., explored methods of providing operator feedback for various work actions of the ANDROS Mk VI teleoperated robot. In a hazardous environment, an extremely heavy workload seriously degrades the productivity of teleoperated robot operators. This CRADA involved the addition of computer power to the robot along with a variety of sensors and encoders to provide information about the robot`s performance in and relationship to its environment. Software was developed to integrate the sensor and encoder information and provide control input to the robot. ANDROS Mkmore » VI robots are presently used by numerous electric utilities to perform tasks in reactors where substantial exposure to radiation exists, as well as in a variety of other hazardous environments. Further, this platform has potential for use in a number of environmental restoration tasks, such as site survey and detection of hazardous waste materials. The addition of sensors and encoders serves to make the robot easier to manage and permits tasks to be done more safely and inexpensively (due to time saved in the completion of complex remote tasks). Prior research on the automation of mobile platforms with manipulators at Oak Ridge National Laboratory`s Center for Engineering Systems Advanced Research (CESAR, B&R code KC0401030) Laboratory, a BES-supported facility, indicated that this type of enhancement is effective. This CRADA provided such enhancements to a successful working teleoperated robot for the first time. Performance of this CRADA used the CESAR laboratory facilities and expertise developed under BES funding.« less
Near Real Time Tools for ISS Plasma Science and Engineering Applications
NASA Astrophysics Data System (ADS)
Minow, J. I.; Willis, E. M.; Parker, L. N.; Shim, J.; Kuznetsova, M. M.; Pulkkinen, A. A.
2013-12-01
The International Space Station (ISS) program utilizes a plasma environment forecast for estimating electrical charging hazards for crews during extravehicular activity (EVA). The process uses ionospheric electron density and temperature measurements from the ISS Floating Potential Measurement Unit (FPMU) instrument suite with the assumption that the plasma conditions will remain constant for one to fourteen days with a low probability for a space weather event which would significantly change the environment before an EVA. FPMU data is typically not available during EVA's, therefore, the most recent FPMU data available for characterizing the state of the ionosphere during EVA is typically a day or two before the start of an EVA or after the EVA has been completed. In addition to EVA support, information on ionospheric plasma densities is often needed for support of ISS science payloads and anomaly investigations during periods when the FPMU is not operating. This presentation describes the application of space weather tools developed by MSFC using data from near real time satellite radio occultation and ground based ionosonde measurements of ionospheric electron density and a first principle ionosphere model providing electron density and temperature run in a real time mode by GSFC. These applications are used to characterize the space environment during EVA periods when FPMU data is not available, monitor for large charges in ionosphere density that could render the ionosphere forecast and plasma hazard assessment invalid, and validate the assumption of 'persistence of conditions' used in deriving the hazard forecast. In addition, the tools are used to provide space environment input to science payloads on ISS and anomaly investigations during periods the FPMU is not operating.
NASA Astrophysics Data System (ADS)
Selva, Jacopo; Costa, Antonio; Sandri, Laura; Rouwet, Dmtri; Tonini, Roberto; Macedonio, Giovanni; Marzocchi, Warner
2015-04-01
Probabilistic Volcanic Hazard Assessment (PVHA) represents the most complete scientific contribution for planning rational strategies aimed at mitigating the risk posed by volcanic activity at different time scales. The definition of the space-time window for PVHA is related to the kind of risk mitigation actions that are under consideration. Short temporal intervals (days to weeks) are important for short-term risk mitigation actions like the evacuation of a volcanic area. During volcanic unrest episodes or eruptions, it is of primary importance to produce short-term tephra fallout forecast, and frequently update it to account for the rapidly evolving situation. This information is obviously crucial for crisis management, since tephra may heavily affect building stability, public health, transportations and evacuation routes (airports, trains, road traffic) and lifelines (electric power supply). In this study, we propose a methodology named BET_VHst (Selva et al. 2014) for short-term PVHA of volcanic tephra dispersal based on automatic interpretation of measures from the monitoring system and physical models of tephra dispersal from all possible vent positions and eruptive sizes based on frequently updated meteorological forecasts. The large uncertainty at all the steps required for the analysis, both aleatory and epistemic, is treated by means of Bayesian inference and statistical mixing of long- and short-term analyses. The BET_VHst model is here presented through its implementation during two exercises organized for volcanoes in the Neapolitan area: MESIMEX for Mt. Vesuvius, and VUELCO for Campi Flegrei. References Selva J., Costa A., Sandri L., Macedonio G., Marzocchi W. (2014) Probabilistic short-term volcanic hazard in phases of unrest: a case study for tephra fallout, J. Geophys. Res., 119, doi: 10.1002/2014JB011252
NASA Astrophysics Data System (ADS)
Selva, Jacopo; Scollo, Simona; Costa, Antonio; Brancato, Alfonso; Prestifilippo, Michele
2015-04-01
Tephra dispersal, even in small amounts, may heavily affect public health and critical infrastructures, such as airports, train and road networks, and electric power supply systems. Probabilistic Volcanic Hazard Assessment (PVHA) represents the most complete scientific contribution for planning rational strategies aimed at managing and mitigating the risk posed by activity during volcanic crises and during eruptions. Short-term PVHA (over time intervals in the order of hours to few days) must account for rapidly changing information coming from the monitoring system, as well as, updated wind forecast, and they must be accomplished in near-real-time. In addition, while during unrest the primary goal is to forecast potential eruptions, during eruptions it is also fundamental to correctly account for the real-time status of the eruption and of tephra dispersal, as well as its potential evolution in the short-term. Here, we present a preliminary application of BET_VHst model (Selva et al. 2014) for Mt. Etna. The model has its roots into present state deterministic procedure, and it deals with the large uncertainty that such procedures typically ignore, like uncertainty on the potential position of the vent and eruptive size, on the possible evolution of volcanological input during ongoing eruptions, as well as, on wind field. Uncertainty is treated by making use of Bayesian inference, alternative modeling procedures for tephra dispersal, and statistical mixing of long- and short-term analyses. References Selva J., Costa A., Sandri L., Macedonio G., Marzocchi W. (2014) Probabilistic short-term volcanic hazard in phases of unrest: a case study for tephra fallout, J. Geophys. Res., 119, doi: 10.1002/2014JB011252
[Intracranial pressure monitoring apparatus for clinical use balanced pressure sensors].
Numoto, M
1976-04-01
Three types of pressure sensors, (1) electric pressure switch, (2) fiber optic pressure switch and (3) pressure indicating bag for intracranial pressure monitoring which were developed by the author are described. Advantages and disadvantages between them are also discussed. The electric pressure switch is relatively simple in construction but has a possibility of producing micro-shock hazard in case of accidental electric leakage. The fiber optic pressure switch is the safest for the micro shock but its structure is rather complicated and fragile. The pressure indicating bag is simple to make and durable to use. However, it has a hydrostatic effect.
Electricity remains a serious workplace hazard.
Proctor, Laura; Kuchibotla, Srin
2013-08-01
Anyone who works in an industrial environment or is employed in the utility, mass transit, industrial goods manufacturing, or telecommunications industry - as well as many others - may be at risk for electrocution. Electric shock costs workers' lives and results in painful and debilitating injuries every year. Lockout/tagout procedures protect against electrocution, as do rubber insulating gloves, which must be worn any time workers are exposed to energized parts operating at 50 volts or higher. Some newer styles of rubber insulating gloves not only protect against electric shock, but also offer the dexterity and flexibility workers need for hours of comfortable wear.
How dangerous are mobile phones, transmission masts, and electricity pylons?
Wood, A W
2006-04-01
Electrical power and mobile communications deliver enormous benefit to society, but there are concerns whether the electric and magnetic field (EMF) emissions associated with the delivery of this benefit are linked to cancer or other health hazards. This article reviews the strength of the available epidemiological and laboratory evidence and notes that this falls short of what is normally required to establish a causal link. However, because of scientific uncertainty a cautious approach is often advocated, but here, too, there may be a tendency to judge these risks more harshly than those in other areas with similar strength of evidence.
NASA Technical Reports Server (NTRS)
Bauer, J. L.
1979-01-01
A review is made of the state-of-the-art in regard to the use of composite materials for reducing the structural mass of automobiles. Reduction of mass provides, in addition to other engineering improvements, increased performance/range advantages that are particularly needed in the electric and hybrid vehicle field. Problems encountered include the attainment of mass production techniques and the prevention of environmental hazards.
American lifelines alliance efforts to improve electric power transmission reliability
Nishenko, S.P.; Savage, W.U.; Honegger, D.G.; McLane, T.R.; ,
2002-01-01
A study was performed on American Lifelines Alliance (ALA) efforts to improve electric power transmission reliability. ALA is a public-private partnership project, with the goal of reducing risks to lifelines from natural hazards and human threat events. The mechanism used by ALA for developing national guidelines for lifeline systems is dependent upon using existing Standards Developing Organizations (SDO) accredited by the American National Standards Institute (ANSI) as means to achieve national consensus.
1981-12-01
STUDIES PROJECT MODIFICATION JFK JOHN F. KENNEDY AIRPORT PATWAS PILOT AUTOMATIC TELEPHONE WEATHER ANSWERING SERVICE JPL JET PROPULSION LABORATORY PDP...wing aircraft, helicopters, and cruise sorship directed at Atmospheric Electricity missiles. The AEHP concepts developed will apply Hazards Protection...atmospheric electricity simulators. 90 THE JOINT AIRPORT WEATHER STUDIES PROJECT John McCarthy National Center for Atmospheric Research Several people raised
Lawrence Livermore National Laboratory Site Seismic Safety Program: Summary of Findings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savy, J B; Foxall, W
The Lawrence Livermore National Laboratory (LLNL) Site Seismic Safety Program was conceived in 1979 during the preparation of the site Draft Environmental Impact Statement. The impetus for the program came from the development of new methodologies and geologic data that affect assessments of geologic hazards at the LLNL site; it was designed to develop a new assessment of the seismic hazard to the LLNL site and LLNL employees. Secondarily, the program was also intended to provide the technical information needed to make ongoing decisions about design criteria for future construction at LLNL and about the adequacy of existing facilities. Thismore » assessment was intended to be of the highest technical quality and to make use of the most recent and accepted hazard assessment methodologies. The basic purposes and objectives of the current revision are similar to those of the previous studies. Although all the data and experience assembled in the previous studies were utilized to their fullest, the large quantity of new information and new methodologies led to the formation of a new team that includes LLNL staff and outside consultants from academia and private consulting firms. A peer-review panel composed of individuals from academia (A. Cornell, Stanford University), the Department of Energy (DOE; Jeff Kimball), and consulting (Kevin Coppersmith), provided review and guidance. This panel was involved from the beginning of the project in a ''participatory'' type of review. The Senior Seismic Hazard Analysis Committee (SSHAC, a committee sponsored by the U.S. Nuclear Regulatory Commission, DOE, and the Electric Power Research Institute) strongly recommends the use of participatory reviews, in which the reviewers follow the progress of a project from the beginning, rather than waiting until the end to provide comments (Budnitz et al., 1997). Following the requirements for probabilistic seismic hazard analysis (PSHA) stipulated in the DOE standard DOE-STD-1023-95, a special effort was made to identify and quantify all types of uncertainties. The final seismic hazard estimates were de-aggregated to determine the contribution of all the seismic sources as well as the relative contributions of potential future earthquakes in terms of their magnitudes and distances from the site. It was found that, in agreement with previous studies, the Greenville Fault system contributes the most to the estimate of the seismic hazard expressed in terms of the probability of exceedance of the peak ground acceleration (PGA) at the center of the LLNL site (i.e., at high frequencies). It is followed closely by the Calaveras and Corral Hollow faults. The Mount Diablo thrust and the Springtown and Livermore faults were not considered in the hazard calculations in the 1991 study. In this study they contributed together approximately as much as the Greenville fault. At lower frequencies, more distant faults such as the Hayward and San Andreas faults begin to appear as substantial contributors to the total hazard. The results of this revision are presented in Figures 1 and 2. Figure 1 shows the estimated mean hazard curve in terms of the annual probability of exceedance of the peak ground acceleration (average of the two horizontal orthogonal components) at the LLNL site, assuming that the local site conditions are similar to those of a generic soil. Figure 2 shows the results in terms of the uniform hazard spectra (pseudo-spectral accelerations for 5% damping) for five return periods. Although this latest revision is based on a completely independent and in many respects very different set of data and methodology from the previous one, it gives essentially the same results for the prediction of the peak ground acceleration (PGA), albeit with a reduced uncertainty. The Greenville fault being a dominant contributor to the hazard, a field investigation was performed to better characterize the probability distribution of the rate of slip on the fault. Samples were collected from a trench located on the northern segment of the Greenville fault, and are in the process of being dated at the LLNL Center for Acceleration Mass Spectrometry (CAMS) using carbon-14. Preliminary results from the dating corroborate the range of values used in the hazard calculations. A final update after completion and qualification (quality assurance) of the date measurements, in the near future, will finalize the distribution of this important parameter, probably using Bayesian updating.« less
Occupational health hazards resulting from elevated work rate situations.
Ohara, H; Nakagiri, S; Itani, T; Wake, K; Aoyama, H
1976-12-01
Some occupational health hazards resulting from an elevated rate of work due to recent mechanization and automatization are discussed on the basis of results of health examinations. A rapid increase of a cervicobrachial disorder among young cash register and packing machine operators has been observed. Switching to the use of electronic cash registers has been shown to have only limited efficacy due to increased operation speed, and high-speed complex finger and hand movements of packer operators have also proven to be as hazardous as key-board operations. The high incidence of low-back pain, in particular gradually developing pain, among workers in electric power supply work has been suggested to be the result of quick and intensified work to meet increasing supply demand. Likewise, the workload of electric locomotive and bullet train drivers has increased in accordance with increased train speeds, and has been shown to have had significant effects on their health particularly in regards to neural strain, intra-cab environment such as air pressure change, vibration, and noise, and rotation on irregular shifts. New steps seem required therefore to meet the new health problems arising from a combination of modern technological changes and elevated working speeds.
Compliance of SLAC_s Laser Safety Program with OSHA Requirements for the Control of Hazardous Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woods, Michael; /SLAC
SLAC's COHE program requires compliance with OSHA Regulation 29CFR1910.147, 'The control of hazardous energy (lockout/tagout)'. This regulation specifies lockout/tagout requirements during service and maintenance of equipment in which the unexpected energization or start up of the equipment, or release of stored energy, could cause injury to workers. Class 3B and Class 4 laser radiation must be considered as hazardous energy (as well as electrical energy in associated equipment, and other non-beam energy hazards) in laser facilities, and therefore requires careful COHE consideration. This paper describes how COHE is achieved at SLAC to protect workers against unexpected Class 3B or Classmore » 4 laser radiation, independent of whether the mode of operation is normal, service, or maintenance.« less
ERIC Educational Resources Information Center
Kontur, F.?J.; de La Harpe, K.; Terry, N.?B.
2015-01-01
We examine how student aptitudes impact how much students learn from doing graded online and written homework in an introductory electricity and magnetism course. Our analysis examines the correlation between successful homework completion rates and exam performance as well as how changes in homework completion correlate with changes in exam…
Lumens, Joost; Tayal, Bhupendar; Walmsley, John; Delgado-Montero, Antonia; Huntjens, Peter R; Schwartzman, David; Althouse, Andrew D; Delhaas, Tammo; Prinzen, Frits W; Gorcsan, John
2015-09-01
Left ventricular (LV) mechanical discoordination, often referred to as dyssynchrony, is often observed in patients with heart failure regardless of QRS duration. We hypothesized that different myocardial substrates for LV mechanical discoordination exist from (1) electromechanical activation delay, (2) regional differences in contractility, or (3) regional scar and that we could differentiate electromechanical substrates responsive to cardiac resynchronization therapy (CRT) from unresponsive non-electrical substrates. First, we used computer simulations to characterize mechanical discoordination patterns arising from electromechanical and non-electrical substrates and accordingly devise the novel systolic stretch index (SSI), as the sum of posterolateral systolic prestretch and septal systolic rebound stretch. Second, 191 patients with heart failure (QRS duration ≥120 ms; LV ejection fraction ≤35%) had baseline SSI quantified by automated echocardiographic radial strain analysis. Patients with SSI≥9.7% had significantly less heart failure hospitalizations or deaths 2 years after CRT (hazard ratio, 0.32; 95% confidence interval, 0.19-0.53; P<0.001) and less deaths, transplants, or LV assist devices (hazard ratio, 0.28; 95% confidence interval, 0.15-0.55; P<0.001). Furthermore, in a subgroup of 113 patients with intermediate electrocardiographic criteria (QRS duration of 120-149 ms or non-left bundle branch block), SSI≥9.7% was independently associated with significantly less heart failure hospitalizations or deaths (hazard ratio, 0.41; 95% confidence interval, 0.23-0.79; P=0.004) and less deaths, transplants, or LV assist devices (hazard ratio, 0.27; 95% confidence interval, 0.12-0.60; P=0.001). Computer simulations differentiated patterns of LV mechanical discoordination caused by electromechanical substrates responsive to CRT from those related to regional hypocontractility or scar unresponsive to CRT. The novel SSI identified patients who benefited more favorably from CRT, including those with intermediate electrocardiographic criteria, where CRT response is less certain by ECG alone. © 2015 American Heart Association, Inc.
10 CFR 835.901 - Radiation safety training.
Code of Federal Regulations, 2011 CFR
2011-01-01
....901(c) commensurate with the hazards in the area and the required controls: (1) Before being permitted... controls, by successful completion of an examination and performance demonstrations: (1) Before being... radiological hazards: (1) Risks of exposure to radiation and radioactive materials, including prenatal...
Report #13-P-0337, July 30, 2013. CSB does not have an effective management system to meet its established performance goal to “conduct incident investigations and safety studies concerning releases of hazardous chemical substances.”
Electric heating of I-84 in Ladd Canyon, Oregon.
DOT National Transportation Integrated Search
2006-06-01
When highway grades in mountainous areas and superelevation on curved sections are combined with adverse winter weather conditions, these sections of highway can become particularly hazardous for large truck traffic. This report covers the design and...
Landscape Hazards in Yukon Communities: Geological Mapping for Climate Change Adaptation Planning
NASA Astrophysics Data System (ADS)
Kennedy, K.; Kinnear, L.
2010-12-01
Climate change is considered to be a significant challenge for northern communities where the effects of increased temperature and climate variability are beginning to affect infrastructure and livelihoods (Arctic Climate Impact Assessment, 2004). Planning for and adapting to ongoing and future changes in climate will require the identification and characterization of social, economic, cultural, political and biophysical vulnerabilities. This pilot project addresses physical landscape vulnerabilities in two communities in the Yukon Territory through community-scale landscape hazard mapping and focused investigations of community permafrost conditions. Landscape hazards are identified by combining pre-existing data from public utilities and private-sector consultants with new geophysical techniques (ground penetrating radar and electrical resistivity), shallow drilling, surficial geological mapping, and permafrost characterization. Existing landscape vulnerabilities are evaluated based on their potential for hazard (low, medium or high) under current climate conditions, as well as under future climate scenarios. Detailed hazard maps and landscape characterizations for both communities will contribute to overall adaptation plans and allow for informed development, planning and mitigation of potentially threatening hazards in and around the communities.
Reversing the sequence: reducing alcohol consumption by overcoming alcohol attentional bias.
Fadardi, Javad Salehi; Cox, W Miles
2009-05-01
The aims of the research were to (a) compare the alcohol attentional bias (AAB) of social, hazardous, and harmful drinkers and (b) assess the effects of alcohol attention-control training on the AAB and alcohol consumption of hazardous and harmful drinkers. Participants were social drinkers (N=40), hazardous drinkers (N=89), and harmful drinkers (N=92). Paper-and-pencil measures were used to collect information about participants' socio-demographic characteristics, health status, motivational structure, drinking-related locus of control and situational self-confidence, readiness to change, affect, and alcohol consumption. Computerized classic, alcohol- and concerns-Stroop tests were administered. All participants were tested individually, with the order of tests counterbalanced across participants. After the baseline assessment, the hazardous and harmful drinkers were trained with the Alcohol Attention-Control Training Program (AACTP) for two and four sessions, respectively. Both samples completed a post-training assessment, and the harmful drinkers also completed 3-month follow-up. Results indicated that (a) the harmful drinkers had larger AAB than the hazardous and the social drinkers; (b) the attentional training reduced the hazardous and harmful drinkers' AAB; and (c) the harmful drinkers showed post-training reductions in alcohol consumption and improvements on the other drinking-related indices. The harmful drinkers' improvements were maintained at the 3-month follow-up.
Flow diagram analysis of electrical fatalities in construction industry.
Chi, Chia-Fen; Lin, Yuan-Yuan; Ikhwan, Mohamad
2012-01-01
The current study reanalyzed 250 electrical fatalities in the construction industry from 1996 to 2002 into seven patterns based on source of electricity (power line, energized equipment, improperly installed or damaged equipment), direct contact or indirect contact through some source of injury (boom vehicle, metal bar or pipe, and other conductive material). Each fatality was coded in terms of age, company size, experience, performing tasks, source of injury, accident cause and hazard pattern. The Chi-square Automatic Interaction Detector (CHAID) was applied to the coded data of the fatal electrocution to find a subset of predictors that might derive meaningful classifications or accidents scenarios. A series of Flow Diagrams was constructed based on CHAID result to illustrate the flow of electricity travelling from electrical source to human body. Each of the flow diagrams can be directly linked with feasible prevention strategies by cutting the flow of electricity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aabakken, J.
This report, prepared by NREL's Strategic Energy Analysis Center, includes up-to-date information on power technologies, including complete technology profiles. The data book also contains charts on electricity restructuring, power technology forecasts, electricity supply, electricity capability, electricity generation, electricity demand, prices, economic indicators, environmental indicators, and conversion factors.
Methods for assessment of stream-related hazards to highways and bridges.
DOT National Transportation Integrated Search
1981-03-01
particular river reach, but also on the behavior of the entire fluvial system of which it is a part. Rivers are complex landforms. A simple and straight forward approach to the identification of river hazards is not always possible. A complete evalua...
49 CFR 173.424 - Excepted packages for radioactive instruments and articles.
Code of Federal Regulations, 2011 CFR
2011-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.424....1 mSv/hour (10 mrem/hour); (e) The active material is completely enclosed by non-active components...
49 CFR 173.424 - Excepted packages for radioactive instruments and articles.
Code of Federal Regulations, 2010 CFR
2010-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.424....1 mSv/hour (10 mrem/hour); (e) The active material is completely enclosed by non-active components...
Zradziński, Patryk; Karpowicz, Jolanta; Gryz, Krzysztof; Leszko, Wiesław
2017-06-27
Low frequency magnetic field, inducing electrical field (Ein) inside conductive structures may directly affect the human body, e.g., by electrostimulation in the nervous system. In addition, the spatial distribution and level of Ein are disturbed in tissues neighbouring the medical implant. Numerical models of magneto-therapeutic applicator (emitting sinusoidal magnetic field of frequency 100 Hz) and the user of hearing implant (based on bone conduction: Bonebridge type - IS-BB or BAHA (bone anchorde hearing aid) type - IS-BAHA) were worked out. Values of Ein were analyzed in the model of the implant user's head, e.g., physiotherapist, placed next to the applicator. It was demonstrated that the use of IS-BB or IS-BAHA makes electromagnetic hazards significantly higher (up to 4-fold) compared to the person without implant exposed to magnetic field heterogeneous in space. Hazards for IS-BAHA users are higher than those for IS-BB users. It was found that applying the principles of directive 2013/35/EU, at exposure to magnetic field below exposure limits the direct biophysical effects of exposure in hearing prosthesis users may exceed relevant limits. Whereas applying principles and limits set up by Polish labor law or the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines, the compliance with the exposure limits also ensures the compliance with relevant limits of electric field induced in the body of hearing implant user. It is necessary to assess individually electromagnetic hazard concerning hearing implant users bearing in mind significantly higher hazards to them compared to person without implant or differences between levels of hazards faced by users of implants of various structural or technological solutions. Med Pr 2017;68(4):469-477. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Development of a Computerized Penetrometer System for Hazardous Waste Site Soils Investigations
1988-08-30
soil to prevent contaminant movement . o To preserve the standard electric cone geometry, i.e., 600 point, 1.4-in. (3.56-cm) OD, 1.54-in. 2 (9.9-cm2...considerable soil movements without cracking or rupturing. The second objective was to preserve the ASTM standard electric cone exterior geometry so as to...electrokinesis, and telluric current phenomena. Of these, the electrochemical and electrokinesis phenomena typically produce the largest voltage magnitude (on
Protection of Electrical Systems from EM Hazards - Design Guide.
1981-09-01
cm) Surface flashover Voltage (KV/cm) This criterion should be met for lighting voltage stresses of either polarity applied at up to 1000 KV/v sec rate...suppressor devices can be predicted. The part failure rate models in the handbook include the effects of part electrical stress , thermal stress , operating... stress . This test series contained over one million device hours of operation at temperatures uF to 145°C. The average duration of testing ranges from
Cassini's RTGs undergo mechanical and electrical verification tests in the PHSF
NASA Technical Reports Server (NTRS)
1997-01-01
Workers in the Payload Hazardous Servicing Facility remove the storage collar from a radioisotope thermoelectric generator (RTG) in preparation for installation on the Cassini spacecraft. Cassini will be outfitted with three RTGs. The power units are undergoing mechanical and electrical verification tests in the PHSF. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle.
Building a Healthy Environment.
ERIC Educational Resources Information Center
Simon, Elizabeth
1997-01-01
Describes how school districts, with the help of a good architect, can construct or renovate schools and avoid most environmental hazards. Issues concerning indoor air quality, asbestos, lead poisoning, ergonomics, and adverse exposure to radon and electric and magnetic fields are addressed. (GR)
40 CFR 63.541 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutants from Secondary Lead Smelting § 63.541 Applicability. (a) The provisions of this subpart apply to the following affected sources at all secondary lead smelters: blast, reverberatory, rotary, and electric smelting furnaces; refining kettles; agglomerating furnaces; dryers; process...
40 CFR 63.541 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hazardous Air Pollutants from Secondary Lead Smelting § 63.541 Applicability. (a) The provisions of this subpart apply to the following affected sources at all secondary lead smelters: blast, reverberatory, rotary, and electric smelting furnaces; refining kettles; agglomerating furnaces; dryers; process...
Remedial actions taken to clean up hazardous waste sites for environmental restoration and potential reuse are often sources of diesel and greenhouse gas (GHG) emissions. Many remediation systems, such as pump-and-treat (P&T), may operate for many years, demanding electricity fr...
Superior Sensor Making Sense in Military, Medicine
NASA Technical Reports Server (NTRS)
2004-01-01
A fiber-optic voltage sensor developed a decade ago for NASA's aircraft and space power systems has been the building block for a string of new sensor products offering safe, accurate detection and measurement for electrically noisy and hazardous environments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... grounded through a suitable resistor at the source transformers, and a grounding circuit, originating at... stationary electrical equipment, if he finds that such exception will not pose a hazard to the miners...
ENGINEERING BULLETIN: IN SITU VITRIFICATION TREATMENT
In situ vitrification (ISV) uses electrical power to heat and melt soil, sludge, mine tailings, buried wastes, and sediments contaminated with organic, inorganic, and metal-bearing hazardous wastes. The molten material cools to form a hard, monolithic, chemically inert, stable...
Donatello, S; Tyrer, M; Cheeseman, C R
2010-01-01
A hazardous waste assessment has been completed on ash samples obtained from seven sewage sludge incinerators operating in the UK, using the methods recommended in the EU Hazardous Waste Directive. Using these methods, the assumed speciation of zinc (Zn) ultimately determines if the samples are hazardous due to ecotoxicity hazard. Leaching test results showed that two of the seven sewage sludge ash samples would require disposal in a hazardous waste landfill because they exceed EU landfill waste acceptance criteria for stabilised non-reactive hazardous waste cells for soluble selenium (Se). Because Zn cannot be proven to exist predominantly as a phosphate or oxide in the ashes, it is recommended they be considered as non-hazardous waste. However leaching test results demonstrate that these ashes cannot be considered as inert waste, and this has significant implications for the management, disposal and re-use of sewage sludge ash.
Wake-Vortex Hazards During Cruise
NASA Technical Reports Server (NTRS)
Rossow, Vernon J.; James, Kevin D.; Nixon, David (Technical Monitor)
1998-01-01
Even though the hazard posed by lift-generated wakes of subsonic transport aircraft has been studied extensively for approach and departure at airports, only a small amount of effort has gone into the potential hazard at cruise altitude. This paper reports on a studio of the wake-vortex hazard during cruise because encounters may become more prevalent when free-flight becomes available and each aircraft, is free to choose its own route between destinations. In order to address the problem, the various fluid-dynamic stages that vortex wakes usually go through as they age will be described along with estimates of the potential hazard that each stage poses. It appears that a rolling-moment hazard can be just as severe at cruise as for approach at airports, but it only persists for several minutes. However, the hazard posed by the downwash in the wake due to the lift on the generator aircraft persists for tens of minutes in a long narrow region behind the generating aircraft. The hazard consists of severe vertical loads when an encountering aircraft crosses the wake. A technique for avoiding vortex wakes at cruise altitude will be described. To date the hazard posed by lift-generated vortex wakes and their persistence at cruise altitudes has been identified and subdivided into several tasks. Analyses of the loads to be encounter and are underway and should be completed shortly. A review of published literature on the subject has been nearly completed (see text) and photographs of vortex wakes at cruise altitudes have been taken and the various stages of decay have been identified. It remains to study and sort the photographs for those that best illustrate the various stages of decay after they are shed by subsonic transport aircraft at cruise altitudes. The present status of the analysis and the paper are described.
Poulos, H M; Camp, A E
2010-02-01
Vegetation management is a critical component of rights-of-way (ROW) maintenance for preventing electrical outages and safety hazards resulting from tree contact with conductors during storms. Northeast Utility's (NU) transmission lines are a critical element of the nation's power grid; NU is therefore under scrutiny from federal agencies charged with protecting the electrical transmission infrastructure of the United States. We developed a decision support system to focus right-of-way maintenance and minimize the potential for a tree fall episode that disables transmission capacity across the state of Connecticut. We used field data on tree characteristics to develop a system for identifying hazard trees (HTs) in the field using limited equipment to manage Connecticut power line ROW. Results from this study indicated that the tree height-to-diameter ratio, total tree height, and live crown ratio were the key characteristics that differentiated potential risk trees (danger trees) from trees with a high probability of tree fall (HTs). Products from this research can be transferred to adaptive right-of-way management, and the methods we used have great potential for future application to other regions of the United States and elsewhere where tree failure can disrupt electrical power.
Nutrition and Resistance to Climatic Stress; With Particular Reference to Man
1949-11-01
significantly to o~rational efficiency, or may reduce significantly the hazard of explosive decompression resulting from combat, when seconds of...the low 1 partial pressure of oxygen in the inspired air is a type of climatic stress presenting a serious hazard to the preservation of...oxygen is a complete defense against this hazard except in combat or in accident. The breath- ing of pure oxygen in an airplane cabin not so
NASA Astrophysics Data System (ADS)
Xu, Z.; Gannon, J. L.; Peek, T. A.; Lin, D.
2017-12-01
One space weather hazard is the Geomagnetically Induced Currents (GICs) in the electric power transmission systems, which is naturally induced geoelectric field during the geomagnetic disturbances (GMDs). GICs are a potentially catastrophic threat to bulk power systems. For instance, the Blackout in Quebec in March 1989 was caused by GMDs during a significant magnetic storm. To monitor the GMDs, the autonomous Space Hazard Monitor (SHM) system is developed recently. The system includes magnetic field measurement from magnetometers and geomagnetic field measurement from electrodes. In this presentation, we introduce the six sites of SHMs which have been deployed in the US continental regions. The data from the magnetometers are processed with the Multiple Observatory Geomagnetic Data Analysis Software (MOGDAS). And the statistical results are presented here. It reveals not only the impacts of space weather over US continental region but also the potential of improving instrumentation development to provide better space weather monitor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Czarnecki, A.; Krause, B.
1997-06-01
We present a complete three-loop calculation of the electric dipole moment of the u and d quarks in the standard model. For the d quark, more relevant for the experimentally important neutron electric dipole moment, we find cancellations which lead to an order of magnitude suppression compared with previous estimates. {copyright} {ital 1997} {ital The American Physical Society}
A cost/benefit analysis of commercial fusion-fission hybrid reactor development
NASA Astrophysics Data System (ADS)
Kostoff, Ronald N.
1983-04-01
A simple algorithm was developed that allows rapid computation of the ratio, R, of present worth of benefits to present worth of hybrid R&D program costs as a function of potential hybrid unit electricity cost savings, discount rate, electricity demand growth rate, total hybrid R&D program cost, and time to complete a demonstration reactor. In the sensitivity study, these variables were assigned nominal values (unit electricity cost savings of 4 mills/kW-hr, discount rate of 4%/year, growth rate of 2.25%/year, total R&D program cost of 20 billion, and time to complete a demonstration reactor of 30 years), and the variable of interest was varied about its nominal value. Results show that R increases with decreasing discount rate and increasing unit electricity savings and ranges from 4 to 94 as discount rate ranges from 5 to 3%/year and unit electricity savings range from 2 to 6 mills/kW-hr. R increases with increasing growth rate and ranges from 3 to 187 as growth rate ranges from 1 to 3.5%/year and unit electricity cost savings range from 2 to 6 mills/kW-hr. R attains a maximum value when plotted against time to complete a demonstration reactor. The location of this maximum value occurs at shorter completion times as discount rate increases, and this optimal completion time ranges from 20 years for a discount rate of 4%/year to 45 years for a discount rate of 3%/year.
Bowers, Alex R.; Tant, Mark; Peli, Eli
2012-01-01
Aims. Homonymous hemianopia (HH), a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind) side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68) completed road tests with sham oblique prism glasses (SP) and real oblique prism glasses (RP). A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P = 0.001), but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving. PMID:23316415
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Tommy Robert; Romero, Philbert Roland; Garcia, Samuel Anthony
During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus maymore » increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.« less
Type C investigation of electrical fabrication projects in ICF Kaiser shops
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huckfeldt, R.A.
1995-06-01
A Type C Investigation Board was convened to investigate an electrical miswiring problem found during the operation of the electrical distribution trailer for the TWRS Rotary Mode Core Sampling Truck {number_sign}2. The trailer was designed by WHC and fabricated ICF KH on site for use in the Characterization Program. This problem resulted in a serious safety hazard since the support truck frame/chassis became electrically energized. This final report provides results of the ``Type C Investigation, Electrical Fabrication Projects in ICF KH Shops, June, 1995.`` It contains the investigation scope, executive summary, relevant facts, analysis, conclusions and corrective actions. DOE Ordermore » 5484.1, ``Environmental Protection, Safety and Health Protection Information Reporting Requirements,`` was followed in preparation of this report. Because the incident was electrical in nature and involved both Westinghouse Hanford Company and ICF Kaiser Hanford organizations, the board included members from both contractors and members with considerable electrical expertise.« less
Underwater electric field detection system based on weakly electric fish
NASA Astrophysics Data System (ADS)
Xue, Wei; Wang, Tianyu; Wang, Qi
2018-04-01
Weakly electric fish sense their surroundings in complete darkness by their active electric field detection system. However, due to the insufficient detection capacity of the electric field, the detection distance is not enough, and the detection accuracy is not high. In this paper, a method of underwater detection based on rotating current field theory is proposed to improve the performance of underwater electric field detection system. First of all, we built underwater detection system based on the theory of the spin current field mathematical model with the help of the results of previous researchers. Then we completed the principle prototype and finished the metal objects in the water environment detection experiments, laid the foundation for the further experiments.
1997-07-18
Jet Propulsion Laboratory (JPL) workers Dan Maynard and John Shuping prepare to install a radioisotope thermoelectric generator (RTG) on the Cassini spacecraft in the Payload Hazardous Servicing Facility (PHSF). The three RTGs which will provide electrical power to Cassini on its mission to the Saturnian system are undergoing mechanical and electrical verification testing in the PHSF. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate far from the Sun where solar power systems are not feasible. The Cassini mission is scheduled for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed for NASA by JPL
1997-07-18
Jet Propulsion Research Lab (JPL) workers use a borescope to verify the pressure relief device bellow's integrity on a radioisotope thermoelectric generator (RTG) that has been installed on the Cassini spacecraft in the Payload Hazardous Servicing Facility. The activity is part of the mechanical and electrical verification testing of RTGs during prelaunch processing. RTGs use heat from the natural decay of plutonium to generate electrical power. The three RTGs on Cassini will enable the spacecraft to operate far from the Sun where solar power systems are not feasible. They will provide electrical power to Cassini on it seven year trip to the Saturnian system and during its four year mission at Saturn.
Gestal, J J
1987-01-01
Except for infectious diseases all the main occupational hazards affecting health workers are reviewed: accidents (explosions, fires, electrical accidents, and other sources of injury); radiation (stochastic and non-stochastic effects, protective measures, and personnel most at risk); exposure to noxious chemicals, whose effects may be either local (allergic eczema) or generalised (cancer, mutations), particular attention being paid to the hazards presented by formol, ethylene oxide, cytostatics, and anaesthetic gases; drug addiction (which is more common among health workers than the general population) and psychic problems associated with promotion, shift work, and emotional stress; and assault (various types of assault suffered by health workers, its causes, and the characterisation of the most aggressive patients). PMID:3307896
30 CFR 56.4600 - Extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
.../oar/docket.html . Follow the instructions for submitting comments on the EPA Air and Radiation Docket... nervous system, and damage to the kidneys), and acute health disorders (e.g., lung irritation and...
Environment/Health/Safety (EHS): Databases
Hazard Documents Database Biosafety Authorization System CATS (Corrective Action Tracking System) (for findings 12/2005 to present) Chemical Management System Electrical Safety Ergonomics Database (for new Learned / Best Practices REMS - Radiation Exposure Monitoring System SJHA Database - Subcontractor Job
Hydrotreater/Distillation Column Hazard Analysis Report Rev. 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowry, Peter P.; Wagner, Katie A.
This project Hazard and Risk Analysis Report contains the results of several hazard analyses and risk assessments. An initial assessment was conducted in 2012, which included a multi-step approach ranging from design reviews to a formal What-If hazard analysis. A second What-If hazard analysis was completed during February 2013 to evaluate the operation of the hydrotreater/distillation column processes to be installed in a process enclosure within the Process Development Laboratory West (PDL-West) facility located on the PNNL campus. The qualitative analysis included participation of project and operations personnel and applicable subject matter experts. The analysis identified potential hazardous scenarios, eachmore » based on an initiating event coupled with a postulated upset condition. The unmitigated consequences of each hazardous scenario were generally characterized as a process upset; the exposure of personnel to steam, vapors or hazardous material; a spray or spill of hazardous material; the creation of a flammable atmosphere; or an energetic release from a pressure boundary.« less
EPA's recently published draft Risk Burn Guidance recommends that hazardous waste combustion facilities complete a mass balance of the total organics (TOs) that may be emitted from the combustor. TOs, consisting of three distinct fractions (volatile, semivolatile, and nonvolatile...
Development of a Multi-Hazard Landscape for Exposure and Risk Interpretation
A complete accounting of potential hazard exposures is critical in the development of any model meant to depict the resilience of a system. This allows for a clear ledger to both assess current risk status along with potential ways to improve resilience. The US EPA is currently...
ROBOTICS IN HAZARDOUS ENVIRONMENTS - REAL DEPLOYMENTS BY THE SAVANNAH RIVER NATIONAL LABORATORY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriikku, E.; Tibrea, S.; Nance, T.
The Research & Development Engineering (R&DE) section in the Savannah River National Laboratory (SRNL) engineers, integrates, tests, and supports deployment of custom robotics, systems, and tools for use in radioactive, hazardous, or inaccessible environments. Mechanical and electrical engineers, computer control professionals, specialists, machinists, welders, electricians, and mechanics adapt and integrate commercially available technology with in-house designs, to meet the needs of Savannah River Site (SRS), Department of Energy (DOE), and other governmental agency customers. This paper discusses five R&DE robotic and remote system projects.
NASA Astrophysics Data System (ADS)
Fustich, C. D.
1980-03-01
A series of transformer room fire tests are reported to demonstate the shock hazard present when automatic sprinklers operate over energized electrical equipment. Fire protection was provided by standard 0.5 inch pendent automatic sprinklers temperature rated at 135 F and installed to give approximately 150 sq ft per head coverage. A 480 v dry transformer was used in the room to provide a three phase, four wire distribution system. It is shown that the induced currents in the test room during the various tests are relatively small and pose no appreciable personnel shock hazard.
Electrocution by arcing: a nonfatal case study.
Solarino, Biagio; Di Vella, Giancarlo
2011-12-01
Accidental electrocution during working activities account for a considerable amount of morbidity and mortality. Workers often misjudge the danger of electric wires or high-tension power cables, thereby exposing themselves to electrocution hazard. This article describes a nonfatal case of injuries by arcing from high-tension power-line cables involving a young farmer who was thrashing an olive tree by means of aluminum ladder. The circumstances surrounding the manner of electrocution and the features of electric injuries are presented and discussed.
Automated Indexing of the Hazardous Substances Data Bank (HSDB)
Nuss, Carlo; Chang, Hua Florence; Moore, Dorothy; Fonger, George C.
2003-01-01
The Hazardous Substances Data Bank (HSDB), produced and maintained by the National Library of Medicine (NLM), contains over 4600 records on potentially hazardous chemicals. To enhance information retrieval from HSDB, NLM has undertaken the development of an automated HSDB indexing protocol as part of its Indexing Initiative. The NLM Indexing Initiative investigates methods whereby automated indexing may partially or completely substitute for human indexing. The poster’s purpose is to describe the HSDB Automated Indexing Project. PMID:14728459
Cleanups In My Community (CIMC) - Federal Facility RCRA Sites, National Layer
Federal facilities are properties owned by the federal government. This data layer provides access to Federal facilities that are Resource Conservation and Recovery Act (RCRA) sites as part of the CIMC web service. The Resource Conservation and Recovery Act, among other things, helps ensure that wastes are managed in an environmentally sound manner so as to protect human health and the environment from the potential hazards of waste disposal.In particular, RCRA tightly regulates all hazardous waste from cradle to grave. In general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide information about their activities to state environmental agencies. These agencies, in turn pass on the information to regional and national EPA offices. Accidents or other activities at facilities that treat, store or dispose of hazardous wastes have sometimes led to the release of hazardous waste or hazardous constituents into soil, ground water, surface water, or air. When that happens, the RCRA Corrective Action program is one program that may be used to accomplish the necessary cleanup.In Cleanups in My Community, you can map or list RCRA Corrective Action sites that are currently undergoing corrective action, sites for which a remedy has been selected, sites for which construction has been completed, and sites where the corrective action cleanup is complete. This data layer shows those RCRA sites that are located at Federa
Chlorine hazard evaluation for the zinc-chlorine electric vehicle battery. Final technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zalosh, R.G.; Bajpai, S.N.; Short, T.P.
1980-04-01
An evaluation of the hazards associated with conceivable accidental chlorine releases from zinc-chlorine electric vehicle batteries is presented. Since commercial batteries are not yet available, this hazard assessment is based both on theoretical chlorine dispersion models and small-scale and large-scale spill tests with chlorine hydrate. Six spill tests involving chlorine hydrate indicate that the danger zone in which chlorine vapor concentrations intermittently exceed 100 ppM extends at least 23 m directly downwind of a spill onto a warm road surface. Chlorine concentration data from the hydrate spill tests compare favorably with calculations based on a quasi-steady area source dispersion modelmore » and empirical estimates of the hydrate decomposition rate. The theoretical dispersion model has been combined with assumed hydrate spill probabilities and current motor vehicle accident statistics in order to project expected chlorine-induced fatality rates. These calculations indicate that expected chlorine fatality rates are several times higher in a city with a warm and calm climate than in a colder and windier city. Calculated chlorine-induced fatality rate projections for various climates are presented as a function of hydrate spill probability in order to illustrate the degree of vehicle/battery crashworthiness required to maintain chlorine-induced fatality rates below current vehicle fatility rates due to fires and asphyxiations.« less
Electrical Safety Program: Nonelectrical Crafts at LANL, Live #12175
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, George
Los Alamos National Laboratory (LANL) and the federal government require those working with or near electrical equipment to be trained on electrical hazards and how to avoid them. Although you might not be trained to work on electrical systems, your understanding of electricity, how it can hurt you, and what precautions to take when working near electricity could save you or others from injury or death. This course, Electrical Safety Program: Nonelectrical Crafts at LANL (12175), provides knowledge of basic electrical concepts, such as current, voltage, and resistance, and their relationship to each other. You will learn how to applymore » these concepts to safe work practices while learning about the dangers of electricity—and associated hazards—that you may encounter on the job. The course also discusses what you can do to prevent electrical accidents and what you should do in the event of an electrical emergency. The LANL Electrical Safety Program is defined by LANL Procedure (P) 101-13. An electrical safety officer (ESO) is well versed in this document and should be consulted regarding electrical questions. Appointed by the responsible line manager (RLM), ESOs can tell you if a piece of equipment or an operation is safe or how to make it safe.« less
Environmentally-benign conversion of biomass residues to electricity
NASA Astrophysics Data System (ADS)
Davies, Andrew
As petroleum resources are finite, it is imperative to use them wisely in energy conversion applications and, at the same time, develop alternative energy sources. Biomass is one of the renewable energy sources that can be used to partially replace fossil fuels. Biomass-based fuels can be produced domestically and can reduce dependency on fuel imports. Due to their abundant supply, and given that to an appreciable extent they can be considered carbon-neutral, their use for power generation is of technological interest. However, whereas biomasses can be directly burned in furnaces, such a conventional direct combustion technique is ill-controlled and typically produces considerable amounts of health-hazardous airborne compounds [1,2]. Thus, an alternative technology for biomass utilization is described herein to address increasing energy needs in an environmentally-benign manner. More specifically, a multi-step process/device is presented to accept granulated or pelletized biomass, and generate an easily-identifiable form of energy as a final product. To achieve low emissions of products of incomplete combustion, the biomass is gasified pyrolytically, mixed with air, ignited and, finally, burned in nominally premixed low-emission flames. Combustion is thus indirect, since the biomass is not directly burned, instead its gaseous pyrolyzates are burned upon mixing with air. Thereby, combustion is well-controlled and can be complete. A demonstration device has been constructed to convert the internal energy of plastics into "clean" thermal energy and, eventually to electricity.
NASA Astrophysics Data System (ADS)
Kontur, F. J.; de La Harpe, K.; Terry, N. B.
2016-12-01
We reply to Rieger, Reinsberg, and Wieman's forgoing Comment [Phys. Rev. Phys. Educ. Res., Comment on "Benefits of completing homework for students with different aptitudes in an introductory electricity and magnetism course" 12, 028001 (2016)].
ERIC Educational Resources Information Center
Kontur, F. J.; de La Harpe, K.; Terry, N. B.
2016-01-01
We reply to Rieger, Reinsberg, and Wieman's forgoing Comment [Phys. Rev. Phys. Educ. Res., Comment on "Benefits of completing homework for students with different aptitudes in an introductory electricity and magnetism course" 12, 028001 (2016)].
Cassini's RTGs undergo mechanical and electrical verification tests in the PHSF
NASA Technical Reports Server (NTRS)
1997-01-01
This radioisotope thermoelectric generator (RTG), at center, is ready for electrical verification testing now that it has been installed on the Cassini spacecraft in the Payload Hazardous Servicing Facility. A handling fixture, at far left, remains attached. This is the third and final RTG to be installed on Cassini for the prelaunch tests. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle.
Cassini's RTGs undergo mechanical and electrical verification tests in the PHSF
NASA Technical Reports Server (NTRS)
1997-01-01
Carrying a neutron radiation detector, Fred Sanders (at center), a health physicist with the Jet Propulsion Laboratory (JPL), and other health physics personnel monitor radiation in the Payload Hazardous Servicing Facility after three radioisotope thermoelectric generators (RTGs) were installed on the Cassini spacecraft for mechanical and electrical verification tests. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed by JPL.
Quantifying Power Grid Risk from Geomagnetic Storms
NASA Astrophysics Data System (ADS)
Homeier, N.; Wei, L. H.; Gannon, J. L.
2012-12-01
We are creating a statistical model of the geophysical environment that can be used to quantify the geomagnetic storm hazard to power grid infrastructure. Our model is developed using a database of surface electric fields for the continental United States during a set of historical geomagnetic storms. These electric fields are derived from the SUPERMAG compilation of worldwide magnetometer data and surface impedances from the United States Geological Survey. This electric field data can be combined with a power grid model to determine GICs per node and reactive MVARs at each minute during a storm. Using publicly available substation locations, we derive relative risk maps by location by combining magnetic latitude and ground conductivity. We also estimate the surface electric fields during the August 1972 geomagnetic storm that caused a telephone cable outage across the middle of the United States. This event produced the largest surface electric fields in the continental U.S. in at least the past 40 years.
78 FR 18614 - National Offshore Safety Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... Continental Shelf (OCS); (b) Electrical Equipment in Hazardous Areas on Foreign Flag Mobile Offshore Drilling... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2013-0182] National Offshore Safety... Advisory Committee Meetings. SUMMARY: The National Offshore Safety Advisory Committee (NOSAC) will meet on...
Commercial Nuclear Steam-Electric Power Plants, Part II
ERIC Educational Resources Information Center
Shore, Ferdinand J.
1974-01-01
Presents the pros and cons of nuclear power systems. Includes a discussion of the institutional status of the AEC, AEC regulatory record, routine low-level radiation hazards, transport of radioactive materials, storage of wastes, and uranium resources and economics of supply. (GS)
29 CFR 1915.157 - Hand and body protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Personal Protective Equipment... employee uses appropriate hand protection and other protective clothing where there is exposure to hazards... working near an ignition source. (c) Electrical protective devices. The employer shall ensure that each...
29 CFR 1915.157 - Hand and body protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Personal Protective Equipment... employee uses appropriate hand protection and other protective clothing where there is exposure to hazards... working near an ignition source. (c) Electrical protective devices. The employer shall ensure that each...
Hazardous Waste Cleanup: Lockheed Martin Corporation in Liverpool, New York
The Lockheed Martin Corporation owns the Electronics Park facility, which is located on Electronics Parkway in the Town of Salina, New York. The Electronics Park facility was constructed in the mid-1940 by the General Electric (GE) Company. Ownership was
Hazardous Waste Cleanup: GE Residential Products Incorporated in Palmer Ward, Puerto Rico
The GE Residential Products, Inc., former Caribe General Electric Products, Inc. (Caribe GE) is an electro-plating facility, located in Palmer Ward, Municipality of Rio Grande, Commonwealth of Puerto Rico. The facility is located on both sides of State
Hazardous Waste Cleanup: Sabic Innovative Plastics US, LLC in Selkirk, New York
The ownership of the facility was transferred from General Electric to Sabic Innovative Plastics in May 2007. The facility is located on Noryl Avenue in the town of Selkirk. The facility is approximately six miles from the Hudson River.
44 CFR 63.6 - Reimbursable relocation costs.
Code of Federal Regulations, 2011 CFR
2011-10-01
... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program IMPLEMENTATION OF SECTION 1306(c) OF THE NATIONAL FLOOD INSURANCE ACT OF 1968 General § 63.6 Reimbursable relocation... flood plain management ordinances, and sewer, septic, electric, gas, telephone, and water connections at...
44 CFR 63.6 - Reimbursable relocation costs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program IMPLEMENTATION OF SECTION 1306(c) OF THE NATIONAL FLOOD INSURANCE ACT OF 1968 General § 63.6 Reimbursable relocation... flood plain management ordinances, and sewer, septic, electric, gas, telephone, and water connections at...
44 CFR 63.6 - Reimbursable relocation costs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program IMPLEMENTATION OF SECTION 1306(c) OF THE NATIONAL FLOOD INSURANCE ACT OF 1968 General § 63.6 Reimbursable relocation... flood plain management ordinances, and sewer, septic, electric, gas, telephone, and water connections at...
44 CFR 63.6 - Reimbursable relocation costs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... OF HOMELAND SECURITY INSURANCE AND HAZARD MITIGATION National Flood Insurance Program IMPLEMENTATION OF SECTION 1306(c) OF THE NATIONAL FLOOD INSURANCE ACT OF 1968 General § 63.6 Reimbursable relocation... flood plain management ordinances, and sewer, septic, electric, gas, telephone, and water connections at...
Letters that provide guidance on asbestos National Emissions Standard of Hazardous Air Pollutants (NESHAP) applicability to linoleum, tar paper, electric wiring, floor tile mastic, caulking compounds, and other similar materials during demolition
46 CFR 153.909 - Completing the Cargo Record Book and record retention: Categories A, B, C, and D.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Completing the Cargo Record Book and record retention... HAZARDOUS MATERIALS Operations Documents and Cargo Information § 153.909 Completing the Cargo Record Book... the Cargo Record Book required under § 153.490 is completed immediately after any of the following...
46 CFR 153.909 - Completing the Cargo Record Book and record retention: Categories A, B, C, and D.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Completing the Cargo Record Book and record retention... HAZARDOUS MATERIALS Operations Documents and Cargo Information § 153.909 Completing the Cargo Record Book... the Cargo Record Book required under § 153.490 is completed immediately after any of the following...
Toxicity of a hazardous chemical mixture in the planarian, Dugesia dorotocephala
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramsdell, H.S.; Matthews, C.M.
1995-12-31
The responses of the planarian, Dugesia dorotocephala to toxic chemical mixtures representative of water contaminants associated with hazardous waste sites have been studied in laboratory experiments. These free-living flatworms are readily maintained under laboratory conditions and are a useful invertebrate model for toxicology studies. Their widespread occurrence also makes them potentially useful for environmental studies. Mature asexual Dugesia dorotocephala were exposed for 14 days to mixtures of seven contaminants frequently detected in water at hazardous waste sites. The complete 1X mixture contained both metals (As, 3.1 ppm; Cr, 0.7 ppm; Pb, 3.7 ppm) and organics (chloroform, 1.5 ppm; benzene, 5.0more » ppm; phenol, 3.4 ppm; trichloroethylene, 3.8 ppm). Groups of planaria were treated with the complete mixture at 0.1X, 1X and 10X concentrations. Additional groups were exposed to the metals-only or organics-only submixtures, also at 0.1X, 1X and 10X concentrations. Treatment solutions were renewed daily. Suppression of fissioning was observed in all of the 1X and 10X treatment groups. Significant mortality occurred only in the 10X complete and 1 0X metals-only treatments. It appears that the toxic effects of the complete mixture are primarily associated with the metal components.« less
Flum, Marian R; Siqueira, Carlos Eduardo; DeCaro, Anthony; Redway, Scott
2010-11-01
Photovoice, a photographic participatory action research methodology was used in a workplace setting to assess hazards that were creating extremely high injury and incidents rates for university custodians and to promote the conditions to eliminate or reduce those hazards. University custodians participated in a Photovoice project to identify, categorize, and prioritize occupational hazards and to discuss and propose solutions to these problems. Results were presented to management and to all custodians for further discussion. The effort was led by a worker-based union-sponsored participatory evaluation team in partnership with a university researcher. Visual depiction of hazardous tasks and exposures among custodians and management focused primarily on improper or unsafe equipment, awkward postures, lifting hazards, and electrical hazards. The process of taking pictures and presenting them created an ongoing discussion among workers and management regarding the need for change and for process improvements, and resulted in greater interest and activity regarding occupational health among the workers. In a follow-up evaluation 1-year later, a number of hazards identified through Photovoice had been corrected. Injury rates for custodians had decreased from 39% to 26%. Photovoice can be an important tool, not just for identifying occupational hazards, but also empowering workers to be more active around health and safety and may facilitate important changes in the workplace. © 2010 Wiley-Liss, Inc.
Current status of environmental, health, and safety issues of lithium ion electric vehicle batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vimmerstedt, L.J.; Ring, S.; Hammel, C.J.
The lithium ion system considered in this report uses lithium intercalation compounds as both positive and negative electrodes and has an organic liquid electrolyte. Oxides of nickel, cobalt, and manganese are used in the positive electrode, and carbon is used in the negative electrode. This report presents health and safety issues, environmental issues, and shipping requirements for lithium ion electric vehicle (EV) batteries. A lithium-based electrochemical system can, in theory, achieve higher energy density than systems using other elements. The lithium ion system is less reactive and more reliable than present lithium metal systems and has possible performance advantages overmore » some lithium solid polymer electrolyte batteries. However, the possibility of electrolyte spills could be a disadvantage of a liquid electrolyte system compared to a solid electrolyte. The lithium ion system is a developing technology, so there is some uncertainty regarding which materials will be used in an EV-sized battery. This report reviews the materials presented in the open literature within the context of health and safety issues, considering intrinsic material hazards, mitigation of material hazards, and safety testing. Some possible lithium ion battery materials are toxic, carcinogenic, or could undergo chemical reactions that produce hazardous heat or gases. Toxic materials include lithium compounds, nickel compounds, arsenic compounds, and dimethoxyethane. Carcinogenic materials include nickel compounds, arsenic compounds, and (possibly) cobalt compounds, copper, and polypropylene. Lithiated negative electrode materials could be reactive. However, because information about the exact compounds that will be used in future batteries is proprietary, ongoing research will determine which specific hazards will apply.« less
Electric field mill network products to improve detection of the lightning hazard
NASA Technical Reports Server (NTRS)
Maier, Launa M.
1987-01-01
An electric field mill network has been used at Kennedy Space Center for over 10 years as part of the thunderstorm detection system. Several algorithms are currently available to improve the informational output of the electric field mill data. The charge distributions of roughly 50 percent of all lightning can be modeled as if they reduced the charged cloud by a point charge or a point dipole. Using these models, the spatial differences in the lightning induced electric field changes, and a least squares algorithm to obtain an optimum solution, the three-dimensional locations of the lightning charge centers can be located. During the lifetime of a thunderstorm, dynamically induced charging, modeled as a current source, can be located spatially with measurements of Maxwell current density. The electric field mills can be used to calculate the Maxwell current density at times when it is equal to the displacement current density. These improvements will produce more accurate assessments of the potential electrical activity, identify active cells, and forecast thunderstorm termination.
The moderating role of implicit alcohol-related cognitions in hazardous alcohol use
Cavanagh, Lucia; Obasi, Ezemenari M.
2015-01-01
The present study applied the Go/No-Go Association Test (GNAT; Nosek & Banaji, 2001) to measure alcohol-related implicit cognitions. Additionally, it assessed the role of implicit cognitions as a potential moderator in the relationship between explicit predictors of alcohol use and hazardous drinking behavior. University undergraduate students (N = 214) completed self-report questionnaires assessing reasons for drinking and reported alcohol use. Participants also completed two GNATs assessing implicit-alcohol-related cognitions associated with attitude (good-bad) and perceived safety (safe-dangerous). As expected, participants held implicit appraisals of alcohol as ‘‘bad’’ and ‘‘dangerous’’ in the context of nonalcoholic drinks, and as ‘‘good’’ and ‘‘safe’’ in the context of licit and illicit drugs. Implicit alcohol-related cognitions moderated the relationship between drinking to cope with negative affect and hazardous drinking and drinking due to cues or craving and hazardous drinking. These findings highlight the multidimensional nature of implicit cognitions and the role of negative implicit alcohol-related associations in moderating relationships between explicit processes and subsequent alcohol use behaviors. PMID:26989352
1997-07-19
Workers in the Payload Hazardous Servicing Facility remove the storage collar from a radioisotope thermoelectric generator (RTG) in preparation for installation on the Cassini spacecraft. Cassini will be outfitted with three RTGs. The power units are undergoing mechanical and electrical verification tests in the PHSF. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle
NASA Astrophysics Data System (ADS)
Lazzari, M.; Loperte, A.; Perrone, A.
2010-03-01
This work, carried out with an integrated methodological approach, focuses on the use of near surface geophysics techniques, such as ground penetrating radar and electrical resistivity tomography (ERT), and geomorphological analysis, in order to reconstruct the cave distribution and geometry in a urban context and, in particular, in historical centres. The interaction during recent centuries between human activity (caves excavation, birth and growth of an urban area) and the characters of the natural environment were the reasons of a progressive increase in hazard and vulnerability levels of several sites. The reconstruction of a detailed cave map distribution is the first step to define the anthropic and geomorphological hazard in urban areas, fundamental basis for planning and assessing the risk.
Influence of long-term storage on fire hazard properties of metal nanopowders
NASA Astrophysics Data System (ADS)
Kyrmakova, O. S.; Sechin, A. I.; Nazarenko, O. B.
2017-08-01
The production and application of nanomaterials is rapidly expanding. Therefore the problem of their properties change during long-term storage becomes essential. The properties of metal nanopowders after long-term storage under ambient conditions were studied and the results are presented in this work. The aluminum, iron, zinc, and copper nanopowders produced by the method of electrical explosion of wires were investigated in this work. The investigation was carried out by X-ray and thermal analysis. The estimation of the flame propagation velocity in the bulk layer of nanopowders was carried out. The characteristics of the nanopowders of nanometals studied are given in terms of their fire hazard. The results can be used for diagnostic of fire hazard of nanomaterials and protection of the enterprises against fire and explosion.
Near Real Time Tools for ISS Plasma Science and Engineering Applications
NASA Technical Reports Server (NTRS)
Minow, Joseph I.; Willis, Emily M.; Parker, Linda Neergaard; Shim, Ja Soon; Kuznetsova, Maria M.; Pulkkinen, Antti, A.
2013-01-01
The International Space Station (ISS) program utilizes a plasma environment forecast for estimating electrical charging hazards for crews during extravehicular activity (EVA). The process uses ionospheric electron density (Ne) and temperature (Te) measurements from the ISS Floating Potential Measurement Unit (FPMU) instrument suite with the assumption that the plasma conditions will remain constant for one to fourteen days with a low probability for a space weather event which would significantly change the environment before an EVA. FPMU data is typically not available during EVA's, therefore, the most recent FPMU data available for characterizing the state of the ionosphere during EVA is typically a day or two before the start of an EVA or after the EVA has been completed. Three near real time space weather tools under development for ISS applications are described here including: (a) Ne from ground based ionosonde measurements of foF2 (b) Ne from near real time satellite radio occultation measurements of electron density profiles (c) Ne, Te from a physics based ionosphere model These applications are used to characterize the ISS space plasma environment during EVA periods when FPMU data is not available, monitor for large changes in ionosphere density that could render the ionosphere forecast and plasma hazard assessment invalid, and validate the "persistence of conditions" forecast assumption. In addition, the tools are useful for providing space environment input to science payloads on ISS and anomaly investigations during periods the FPMU is not operating.
Flasher Powered by Photovoltaic Cells and Ultracapacitors
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.; Soltis, Richard F.
2003-01-01
A unique safety flasher powered by photovoltaic cells and ultracapacitors has been developed. Safety flashers are used wherever there are needs to mark actually or potentially hazardous locations. Examples of such locations include construction sites, highway work sites, and locations of hazardous operations. Heretofore, safety flashers have been powered by batteries, the use of which entails several disadvantages: Batteries must be kept adequately charged, and must not be allowed to become completely discharged. Batteries have rather short cycle lives, and their internal constituents that react chemically to generate electricity deteriorate (and hence power-generating capacities decrease) over time. The performances of batteries are very poor at low temperatures, which often occur in the circumstances in which safety flashers are most needed. The disposal of batteries poses a threat to the environment. The development of the present photovoltaic/ultracapacitor- powered safety flasher, in which the ultracapacitors are used to store energy, overcomes the aforementioned disadvantages of using batteries to store energy. The ultracapacitors in this flasher are electrochemical units that have extremely high volumetric capacitances because they contain large-surface-area electrodes separated by very small gaps. Ultracapacitors have extremely long cycle lives, as compared to batteries; consequently, it will never be necessary to replace the ultracapacitors in the safety flasher. The reliability of the flasher is correspondingly increased, and the life-of-system cost and the adverse environmental effects of the flasher are correspondingly reduced. Moreover, ultracapacitors have excellent low-temperature characteristics, are maintenance-free, and provide consistent performance over time.
Lightweight diesel aircraft engines for general aviation
NASA Technical Reports Server (NTRS)
Berenyi, S. G.
1983-01-01
Two different engines were studied. The advantages of a diesel to general aviation were reduced to fuel consumption, reduced operating costs, and reduced fire and explosion hazard. There were no ignition mixture control or inlet icing problems. There are fewer controls and no electrical interference problems.
46 CFR 110.10-1 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Classing Mobile Offshore Drilling Units, Part 4 Machinery and Systems, 2001 (“ABS MODU Rules”), IBR... Hazardous (Classified) Locations: Type of Protection—Encapsulation “m”, approved July 31, 2009 (“ANSI/ISA... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as...
Hazardous Waste Cleanup: Standard T Chemical Company Incorporated in Linden, New Jersey
The Standard T Chemical Company facility was located at 1312 Elizabeth Avenue, on a 2.1 acre parcel in an industrially zoned area of Linden, New Jersey. Standard T produced specialty inks, lacquers and varnishes for marking electrical wire and cable.
30 CFR 77.1103 - Flammable liquids; storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... storage tanks shall be mounted securely on firm foundations. Outlet piping shall be provided with flexible connections or other special fittings to prevent adverse effects from tank settling. (c) Fuel lines shall be... hazards. (d) Areas surrounding flammable-liquid storage tanks and electric substations and transformers...
NASA Technical Reports Server (NTRS)
Dowler, W. L.
1979-01-01
High strength steel pipeline carries hot mixture of powdered coal and coal derived oil to electric-power-generating station. Slurry is processed along way to remove sulfur, ash, and nitrogen and to recycle part of oil. System eliminates hazards and limitations associated with anticipated coal/water-slurry pipelines.
Reyes, Miguel Angel; Novak, Thomas
2016-03-01
Large lead-acid batteries are predominantly used throughout the mining industry to power haulage, utility, and personnel-carrier vehicles. Without proper operation and maintenance, the use of these batteries can introduce mechanical and electrical hazards, particularly in the confined, and potentially dangerous, environment of an underground coal mine. A review of the Mine Safety and Health Administration accident/illness/injury database reveals that a significant number of injuries occur during the maintenance and repair of lead-acid batteries. These injuries include burns from electrical arcing and acid exposure, as well as strained muscles and crushed hands. The National Institute for Occupational Safety and Health investigated the design and implementation of these batteries to identify safety interventions that can mitigate these inherent hazards. This paper promotes practical design modifications, such as reducing the size and weight of battery assembly lids in conjunction with lift assists, as well as using five-pole cable connectors to improve safety.
Reyes, Miguel Angel; Novak, Thomas
2016-01-01
Large lead-acid batteries are predominantly used throughout the mining industry to power haulage, utility, and personnel-carrier vehicles. Without proper operation and maintenance, the use of these batteries can introduce mechanical and electrical hazards, particularly in the confined, and potentially dangerous, environment of an underground coal mine. A review of the Mine Safety and Health Administration accident/illness/injury database reveals that a significant number of injuries occur during the maintenance and repair of lead-acid batteries. These injuries include burns from electrical arcing and acid exposure, as well as strained muscles and crushed hands. The National Institute for Occupational Safety and Health investigated the design and implementation of these batteries to identify safety interventions that can mitigate these inherent hazards. This paper promotes practical design modifications, such as reducing the size and weight of battery assembly lids in conjunction with lift assists, as well as using five-pole cable connectors to improve safety. PMID:27784953
Gryz, Krzysztof; Karpowicz, Jolanta
2014-01-01
Electromagnetic fields used in physiotherapeutic treatment affect not only patients, but also physiotherapists, patients not undergoing treatment and electronic medical equipment. The aim of the work was to study the parameters of the electromagnetic fields of physiotherapeutic devices with respect to requirements regarding the protection of electronic devices, including medical implants, against electromagnetic intererence, and the protection of the general public (patients not undergoing treatment and bystanders), as well as medical personnel, against the health hazards caused by electromagnetic exposure. The spatial distribution of electric and magnetic field strength was investigated near 3 capacitive short-wave and 3 long-wave diathermies and 3 ultrasound therapy units, as along with the capacitive electric currents caused by electromagnetic field interaction in the upper limbs of the physiotherapists operating these devices. The physiotherapists' exposure to electromagnetic fields depends on the spatial organisation of the workspace and their location during treatment. Electric fields able to interfere with the function of electronic medical implants and in whic anyone not undergoing treatment should not be present were measured up to 150-200 cm away from active applicators of short-wave diathermy, and up to 40-45 cm away from long-wave diathermy ones. Electric fields in which workers should not be present were measured up to 30-40 cm away from the applicators and cables of active short-wave diathermy devices. A capacitive electric current with a strength exceeding many times the international recommendations regarding workers protection was measured in the wrist while touching applicators and cables of active short-wave diathermy devices. The strongest environmental electromagnetic hazards occur near short-wave diathermy devices, and to a lesser degree near long-wave diathermy devices, but were not found near ultrasound therapy units.
Sudiajeng, Lilik; Adiputra, Nyoman; Leibbrandt, Richard
2012-12-01
This research was conducted to assess the positive effect of the ergonomics work station on the health impairment and electrical energy usage at the woodworking workshop in Bali, Indonesia. Woodworking workshops are dangerous, particularly when they are used improperly. Workers are exposed to health hazards that cause health impairment and inefficiencies in their work conditions. A preliminary study at a woodworking workshop at the Bali State Polytechnic showed that the work station was not suitable to body size of the participants and caused awkward postures. In addition, there was also an inappropriate physical work environment. Both inappropriate work station and physical work environment caused participants to be less active and motivated. This paper reports on an experimental study into the effects of an ergonomic intervention at this workshop. The participants were 2 groups of male students with 10 participants in each group. The first group performed the task with the original work station as a control group, while the second group performed the task with the new work station. The study found a significant difference between groups (p < 0.05) both for the health impairment and the electrical energy usage. The ergonomics intervention on the work station decreased the working heart rate (16.7%), the total score of musculoskeletal disorders (17.3%), and the total score of psychological fatigue (21.5%). Furthermore, it also decreased the electrical energy usage (38.7%). This shows that an ergonomics intervention on work station decreased the health impairment and saved electrical energy usage. It also protected the workers from woodworking hazards and allowed participants to perform their tasks in healthy, safe, convenient and efficient work conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Copps, Kevin D.
The Sandia Analysis Workbench (SAW) project has developed and deployed a production capability for SIERRA computational mechanics analysis workflows. However, the electrical analysis workflow capability requirements have only been demonstrated in early prototype states, with no real capability deployed for analysts’ use. This milestone aims to improve the electrical analysis workflow capability (via SAW and related tools) and deploy it for ongoing use. We propose to focus on a QASPR electrical analysis calibration workflow use case. We will include a number of new capabilities (versus today’s SAW), such as: 1) support for the XYCE code workflow component, 2) data managementmore » coupled to electrical workflow, 3) human-in-theloop workflow capability, and 4) electrical analysis workflow capability deployed on the restricted (and possibly classified) network at Sandia. While far from the complete set of capabilities required for electrical analysis workflow over the long term, this is a substantial first step toward full production support for the electrical analysts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-11-28
The testimony concerns the support of NIOSH for the OSHA proposed rule on Electric Power Generation, Transmission and Distribution. NIOSH in particular comments on control of hazardous energy, cardiopulmonary resuscitation, line mechanics, and enclosed spaces. NIOSH estimates that 80 to 90% of the fatalities occurring in the industry occur among line mechanics. NIOSH strongly supports OSHA in applying the standard both electric utility companies and to power generation, transmission and distribution installations not under control of electric utilities. In addition to evaluating electrocutions to find effective ways for workers to avoid electrical injury or fatality, NIOSH has published recommendations formore » providing emergency medical care when workers do inadvertently contact electrical energy. NIOSH is not aware of any epidemiologic study which collected sufficient data to directly address the issue of successful resuscitation following contact with electrical energy. A review of pertinent epidemiologic studies and standard medical practice supports the NIOSH recommendation that workers who may contact energized electrical circuit work in pairs and that both members of the team be trained in cardiopulmonary resuscitation.« less
Pioneer 10. [observations of Jupiter environment and asteroid belt hazards
NASA Technical Reports Server (NTRS)
Hall, C. F.
1974-01-01
On Dec. 4, 1973, after 21 months in flight, Pioneer 10 passed by Jupiter at a distance within 130,000 km of its cloud tops. During the month before and after, instrumentation on the spacecraft made a number of scientific measurements of the Jupiter environment, thus completing one of three scientific objectives of the mission. Previously, Pioneer 10 had explored the asteroid belt and had completed the second scientific objective by determining that the belt did not present a hazard to spacecraft passing through it. The third objective, the exploration of interplanetary phenomena, started with the launch of Pioneer 10 and will not be completed until 1977 when the spacecraft nears the orbit of Uranus and the signal from the spacecraft becomes too weak to be heard at ground receivers.
Risk to the public from carbon fibers released in civil aircraft accidents
NASA Technical Reports Server (NTRS)
1980-01-01
Because carbon fibers are strong, stiff, and lightweight, they are attractive for use in composite structures. Because they also have high electrical conductivity, free carbon fibers settling on electrical conductors can cause malfunctions. If released from the composite by burning, the fibers may become a hazard to exposed electrical and electronic equipment. As part of a Federal study of the potential hazard associated with the use of carbon fibers, NASA assessed the public risk associated with crash fire accidents of civil aircraft. The NASA study projected a dramatic increase in the use of carbon composites in civil aircraft and developed technical data to support the risk assessment. Personal injury was found to be extremely unlikely. In 1993, the year chosen as a focus for the study, the expected annual cost of damage caused by released carbon fibers is only $1000. Even the worst-case carbon fiber incident simulated (costing $178,000 once in 34,000 years) was relatively low-cost compared with the usual air transport accident cost. On the basis of these observations, the NASA study concluded that exploitation of composites should continue, that additional protection of avionics is unnecessary, and that development of alternate materials specifically to overcome this problem is not justified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shortlidge, C.C.
SatCon technology Corporation has completed design, fabrication, and the first round of test of a 373 kW (500 hp), two-spool, intercooled gas turbine engine with integral induction type alternators. This turbine alternator is the prime mover for a World Sports Car class hybrid electric vehicle under development by Chrysler Corporation. The complete hybrid electric vehicle propulsion system features the 373 kW (500 hp) turbine alternator unit, a 373 kW (500 hp) 3.25 kW-h (4.36 hp-h) flywheel, a 559 kW (750 hp) traction motor, and the propulsion system control system. This paper presents and discusses the major attributes of the controlmore » system associated with the turbine alternator unit. Also discussed is the role and operational requirements of the turbine unit as part of the complete hybrid electric vehicle propulsion system.« less
Wakamoto, Koki; Doi, Shigehiro; Nakashima, Ayumu; Kawai, Toru; Kyuden, Yasufumi; Naito, Takayuki; Asai, Mariko; Takahashi, Shunsuke; Murakami, Masaaki; Masaki, Takao
2018-03-01
This study was performed to investigate the effect of the balloon dilation pressure on the 12-month patency rate in patients with failed arteriovenous fistulas undergoing hemodialysis. In this multicenter, prospective, randomized trial, the 4-mm-diameter YOROI balloon was used for dilation of stenotic lesions. The balloons were inflated to a pressure of 8 atm (low-pressure group) or 30 atm to achieve complete expansion (high-pressure group). The 12-month patency rate after balloon angioplasty was analyzed by the Kaplan-Meier method and log-rank test and/or a Cox proportional hazard model. We also investigated the dilation pressure required to achieve complete expansion in the high-pressure group. In total, 71 patients were enrolled and allocated to either the low-pressure group (n = 34) or the high-pressure group (n = 37). The 12-month patency rates showed no significant difference between the low- and high-pressure groups (47% and 49%, respectively; p = 0.87). In the low-pressure group, the patency rate was not different between patients with complete dilation and residual stenosis (44% and 50%, respectively; p = 0.87). The Cox proportional hazard model revealed that the 12-month patency rate was associated with the stenosis diameter (hazard ratio 0.36; p = 0.001) and the presence of diabetes (hazard ratio 0.33; p = 0.018). Finally, the pressure required to achieve complete dilation was ≤20 atm in 76% of patients and ≤30 atm in 97% of patients. One patient required a dilation pressure of >30 atm. The patency rate does not differ between low-pressure dilation and high-pressure dilation.
Typewriter Modifications for Persons Who Are High-Level Quadriplegics.
ERIC Educational Resources Information Center
O'Reagan, James R.; And Others
Standard, common electric typewriters are not completely suited to the needs of a high-level quadriplegic typing with a mouthstick. Experiences show that for complete control of a typewriter a mouthstick user needs the combined features of one-button correction, electric forward and reverse indexing, and easy character viewing. To modify a…
46 CFR 169.685 - Electric heating and cooking equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SCHOOL VESSELS Machinery and Electrical Electrical Installations Operating at Potentials of 50 Volts Or... designed as to permit complete cleaning, maintenance, and repair. (c) Doors for electric cooking equipment must be provided with heavy duty hinges and locking devices to prevent accidental opening in heavy seas...
2014-03-05
CAPE CANAVERAL, Fla. – The Project Morpheus prototype lander touches down in the automated landing and hazard avoidance technology, or ALHAT, hazard field after completing its sixth free flight test at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The 82-second test began at 11:32 a.m. EST with the Morpheus lander launching from the ground over a flame trench and ascending to 465 feet. The lander flew forward, covering 633 feet while performing a 55-foot divert to emulate a hazard avoidance maneuver before descending and landing on a dedicated pad inside the hazard field. Morpheus landed 10 inches west of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Frankie Martin
EVA Hazards due to TPS Inspection and Repair
NASA Technical Reports Server (NTRS)
Stewart, Christine E.
2007-01-01
Tile inspection and repair activities have implicit hazards associated with them. When an Extra Vehicular Activities (EVA) crewmember and associated hardware are added into the equation, additional hazards are introduced. Potential hazards to the Extravehicular Mobility Unit (EMU), the Orbiter or the crew member themselves are created. In order to accurately assess the risk of performing a TPS inspection or repair, an accurate evaluation of potential hazards and how adequately these hazards are controlled is essential. The EMU could become damaged due to sharp edges, protrusions, thermal extremes, molten metal or impact with the Orbiter. Tools, tethers and the presence of a crew member in the vicinity of the Orbiter Thermal Protection System (TPS) pose hazards to the Orbiter. Hazards such as additional tile or Reinforced Carbon-Carbon (RCC) damage from a loose tool, safety tethers, crewmember or arm impact are introduced. Additionally, there are hazards to the crew which should be addressed. Crew hazards include laser injury, electrical shock, inability to return to the airlock for EMU failures or Orbiter rapid safing scenarios, as well as the potential inadvertent release of a crew member from the arm/boom. The aforementioned hazards are controlled in various ways. Generally, these controls are addressed operationally versus by design, as the majority of the interfaces are to the Orbiter and the Orbiter design did not originally account for tile repair. The Shuttle Remote Manipulator System (SRMS), for instance, was originally designed to deploy experiments, and therefore has insufficient design controls for retention of the Orbiter Boom Sensor System (OBSS). Although multiple methods to repair the Orbiter TPS exist, the majority of the hazards are applicable no matter which specific repair method is being performed. TPS Inspection performed via EVA also presents some of the same hazards. Therefore, the hazards common to all TPS inspection or repair methods will be addressed.
Cassini's RTGs undergo mechanical and electrical verification tests in the PHSF
NASA Technical Reports Server (NTRS)
1997-01-01
Jet Propulsion Laboratory (JPL) worker Mary Reaves mates connectors on a radioisotope thermoelectric generator (RTG) to power up the Cassini spacecraft, while quality assurance engineer Peter Sorci looks on. The three RTGs which will be used on Cassini are undergoing mechanical and electrical verification testing in the Payload Hazardous Servicing Facility. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed by JPL.
Cassini's RTGs undergo mechanical and electrical verification testing in the PHSF
NASA Technical Reports Server (NTRS)
1997-01-01
Jet Propulsion Laboratory (JPL) workers carefully roll into place a platform with a second radioisotope thermoelectric generator (RTG) for installation on the Cassini spacecraft. In background at left, the first of three RTGs already has been installed on Cassini. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. The power units are undergoing mechanical and electrical verification testing in the Payload Hazardous Servicing Facility. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate far from the Sun where solar power systems are not feasible. The Cassini mission is scheduled for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed for NASA by JPL.
78 FR 58989 - Electrical Equipment in Hazardous Locations; Extension of Comment Period
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... to foreign Mobile Offshore Drilling Units (MODUs), floating facilities, and vessels that engage in... offshore supply vessels (OSVs). The proposed regulations would expand the list of national and... Purpose On September 6, 2013, we received a letter from the International Association of Drilling...
77 FR 71607 - Mobile Offshore Drilling Unit (MODU) Electrical Equipment Certification Guidance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-03
... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2012-0839] Mobile Offshore Drilling... hazardous areas on foreign-flagged Mobile Offshore Drilling Units (MODUs) that have never operated, but... International Maritime Organization (IMO) Code for the Construction and Equipment of Mobile Offshore Drilling...
Hazardous Waste Cleanup: Von Roll Isola USA Incorporated in Schenectady, New York
The Riverview facility is a 52-acre manufacturing facility located on Von Roll Drive in Schenectady, New York. The facility is owned and operated by Von Roll Isola USA, Inc., and produces solid and liquid insulating materials and tapes for the electrical
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500-5 Material. (a) Tanks shall be made from open-hearth or electric steel of uniform quality. Material...
29 CFR 1910.135 - Head protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Personal Protective Equipment § 1910.135 Head protection. (a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working... shall ensure that a protective helmet designed to reduce electrical shock hazard is worn by each such...
29 CFR 1910.135 - Head protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Personal Protective Equipment § 1910.135 Head protection. (a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working... shall ensure that a protective helmet designed to reduce electrical shock hazard is worn by each such...
78 FR 13097 - Electric Power Research Institute; Seismic Evaluation Guidance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-26
... outcrop motion for which the soil layers above the foundation elevation have been removed. Updating the... performing soil-structure interaction analyses. Consistent with guidance described in DC/COL-ISG-017, ``Ensuring Hazard-Consistent Seismic Input for Site Response and Soil Structure Interaction Analyses,'' the...
Qiu, Youai; Kong, Wei-Jun; Struwe, Julia; Sauermann, Nicolas; Rogge, Torben; Scheremetjew, Alexej; Ackermann, Lutz
2018-05-14
Rhodium(III) catalysis has enabled a plethora of oxidative C-H functionalizations, which predominantly employ stoichiometric amounts of toxic and/or expensive metal oxidants. In contrast, we herein describe the first electrochemical rhodium-catalyzed C-H activation that avoids hazardous chemical oxidants. Environmentally benign twofold C-H/C-H functionalizations were accomplished with weakly coordinating benzoic acids and benzamides, employing electricity as the terminal oxidant and generating H 2 as the sole byproduct. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Justifying measures to correct functional state of operators varying in personal anxiety].
2012-01-01
Workers of operating and dispatching occupations are exposed to high nervous and emotional exertion that result in increased personal anxiety, working stress and overstrain. That requires physiologically justified correction of hazardous psycho-physiologic states via various prophylactic measures (stay in schungite room, autogenous training, central electric analgesia, electric acupuncture). Attempted relaxation sessions in schungite room revealed in highly anxious individuals an increased velocity of visual signals perception, of attention concentration and shifting. Autogenous training sessions improve memory and have significant hypotensive effect in highly anxious individuals.
Completion Time Dynamics of Doctoral Studies at Makerere University: A Hazard Model Evaluation
ERIC Educational Resources Information Center
Wamala, Robert; Oonyu, Joseph; Ocaya, Bruno
2011-01-01
Issues related to attrition and completion time of graduate studies are certainly an internationally challenging and important area of higher education literature. In this paper, completion time dynamics of doctoral studies at Makerere University were investigated based on data extracted for all 295 candidates in the commencement cohorts from 2000…
Savage, W.U.; Nishenko, S.P.; Honegger, D.G.; Kempner, L.
2006-01-01
Electric power utilities are familiar with and skilled in preparing for and responding to almost-routine natural hazard events such as strong wind and ice storms and seasonal floods, as well as intentional human acts such as vandalism. Recent extreme weather (hurricanes Katrina and Rita), extremely destructive international earthquakes (in Sumatra and Pakistan), and nation-wide concerns regarding future terrorist attacks have increased the pressure on utilities to take appropriate steps to avoid being overwhelmed by such infrequent and exceedingly severe events. Determining what constitutes the appropriate steps to take requires various levels of understanding of the specific hazards and the risks faced by the utility. The American Lifelines Alliance (www. americanlifelinesalliance.org) has prepared a Guideline that provides clear, concise, and nationally-applicable guidance on determining the scope and level of effort necessary to assess power system performance in the wide range of natural hazard or human threat events. Included in this Guideline are specific procedures to follow and information to consider in performing standardized assessments. With the results of such assessments, utility owners can effectively establish and carry out risk management programs that will lead to achieving appropriate levels of performance in future events. The Guideline incorporates an inquiry-driven process with a two-phase performance assessment that can be applied to power systems of any size. The screening phase enables systems or components that are clearly not at risk to be screened out early. The subsequent analysis phase uses results from the screening phase to prioritize and allocate resources for more detailed assessments of hazard, vulnerability, and system performance. This process helps assure that the scope of the assessment meets the specific performance objectives of the inquiry. A case history is presented to illustrate the type of experience with an inquiry-driven process that was considered in developing the Guideline to meet the diverse needs of utility personnel in engineering, operations, and management. Copyright ASCE 2007.
Seismic hazard in the eastern United States
Mueller, Charles; Boyd, Oliver; Petersen, Mark D.; Moschetti, Morgan P.; Rezaeian, Sanaz; Shumway, Allison
2015-01-01
The U.S. Geological Survey seismic hazard maps for the central and eastern United States were updated in 2014. We analyze results and changes for the eastern part of the region. Ratio maps are presented, along with tables of ground motions and deaggregations for selected cities. The Charleston fault model was revised, and a new fault source for Charlevoix was added. Background seismicity sources utilized an updated catalog, revised completeness and recurrence models, and a new adaptive smoothing procedure. Maximum-magnitude models and ground motion models were also updated. Broad, regional hazard reductions of 5%–20% are mostly attributed to new ground motion models with stronger near-source attenuation. The revised Charleston fault geometry redistributes local hazard, and the new Charlevoix source increases hazard in northern New England. Strong increases in mid- to high-frequency hazard at some locations—for example, southern New Hampshire, central Virginia, and eastern Tennessee—are attributed to updated catalogs and/or smoothing.
Occupational Health and the Arts.
Hinkamp, David L; McCann, Michael; Babin, Angela
2017-09-01
Work in the visual arts, performing arts, and writing can involve exposures to occupational hazards, including hazardous materials, equipment, and conditions, but few art workplaces have strong occupational health resources. Literature searches were conducted for articles that illustrate these concerns. Medical databases were searched for art-related health articles. Other sources were also reviewed, including, unindexed art-health publications, and popular press articles. Information was located that described some exposed populations, art-related hazards, and resulting disorders. Anecdotal reports were used when more complete data were not available. Health hazards in the arts are significant. Occupational health professionals are familiar with most of these concerns and understand their treatment and prevention. The occupational health approach can reduce the health hazards encountered by at-risk art workers. Additional research would benefit these efforts. Resources for further information are available.
Tertinger, D A; Greene, B F; Lutzker, J R
1984-01-01
Parents may be charged with child abuse or neglect or both on the basis of a variety of circumstances. Child neglect, for example, is often documented when caseworkers observe that the family's home itself is so poorly kept that it presents an environment in which young children have ready access to lethal hazards such as poisons, uncovered wall outlets, and firearms. In this study, we describe the development of a Home Accident Prevention Inventory (HAPI) which was validated and used to assess hazards in the homes of several families under state protective service for child abuse and neglect. The HAPI included five categories of hazards: fire and electrical, mechanical-suffocation, ingested object suffocation, firearms, and solid/liquid poisons. Following the collection of baseline data, parents were presented with a treatment package that included instructions and demonstrations on making hazards inaccessible to children, plus feedback regarding the number and location of hazards in the home. The multiple-baseline design across hazardous categories in each family's home showed that the package resulted in decreases in the number of these accessible hazards. These improvements were maintained over an extended period of unannounced follow-up checks. This research provides a model for the development and assessment of an area previously unexamined in the child abuse and neglect literature. PMID:6735949
Teamwork tools and activities within the hazard component of the Global Earthquake Model
NASA Astrophysics Data System (ADS)
Pagani, M.; Weatherill, G.; Monelli, D.; Danciu, L.
2013-05-01
The Global Earthquake Model (GEM) is a public-private partnership aimed at supporting and fostering a global community of scientists and engineers working in the fields of seismic hazard and risk assessment. In the hazard sector, in particular, GEM recognizes the importance of local ownership and leadership in the creation of seismic hazard models. For this reason, over the last few years, GEM has been promoting different activities in the context of seismic hazard analysis ranging, for example, from regional projects targeted at the creation of updated seismic hazard studies to the development of a new open-source seismic hazard and risk calculation software called OpenQuake-engine (http://globalquakemodel.org). In this communication we'll provide a tour of the various activities completed, such as the new ISC-GEM Global Instrumental Catalogue, and of currently on-going initiatives like the creation of a suite of tools for the creation of PSHA input models. Discussion, comments and criticism by the colleagues in the audience will be highly appreciated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, Shan-Shan, E-mail: sschung@hkbu.edu.hk; Zhang Chan, E-mail: abigailchanzhang@gmail.com
2011-12-15
Graphical abstract: Highlights: > The most recent specific WEEE laws of China are reviewed and evaluated. > Take-back requirement is vaguely defined. > The 'environmental expiry date' requirement is redundant. > Use of a 'multiple enforcement body' approach has hampered enforcement. - Abstract: With the increasing number of recycling mishaps in connection with waste electronic and electrical equipment (WEEE) in the People's Republic of China, it is imperative that the handling and recycling of WEEE be sufficiently regulated in China. Regulations covering three major issues, namely, take-back issues, controls on hazardous substances in WEEE and the assurance of good environmentalmore » management in WEEE plants, were promulgated between 2006 and 2008. The evaluation in this country report shows that few of these regulatory measures have performed satisfactorily in terms of enforcement, of public acceptance and of environmental concerns. In brief, the take-back requirements and the associated financial responsibilities are only vaguely defined; the control on hazardous substances and the so-called 'environmental expiry date' requirements cannot be properly enforced, and the resources needed to ensure the satisfactory enforcement of the environmental abatement and pollution control requirements in WEEE plants are overwhelming. In addition, the use of a 'multiple enforcement body' approach to the control of hazardous substances in WEEE is an indication that the Chinese government lacks the determination to properly enforce the relevant legal requirements.« less
Hazardous Waste Cleanup: G.E.C. Alstrom Transportation Incorporated in Hornell, New York
The primary use at G.E.C. has been for railcar repair and construction. The two main operational areas have been a refueling area and a large service shop. The major users of the site have included the Erie-Lackawana Railroad, Conrail, General Electric
46 CFR 111.105-33 - Mobile offshore drilling units.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...
46 CFR 111.105-33 - Mobile offshore drilling units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...
46 CFR 111.105-33 - Mobile offshore drilling units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...
46 CFR 111.105-33 - Mobile offshore drilling units.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...
46 CFR 111.105-33 - Mobile offshore drilling units.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...
Hazardous Waste Cleanup: Entergy Indian Point 3 Nuclear Generating in Buchanan, New York
Indian Point Unit 3 is a nuclear-powered electricity generating plant located in the village of Buchanan, Westchester County, New York. The facility was constructed on the former park land in the mid-1970s and encompasses approximately 75 acres on the east
40 CFR 63.9990 - What are the subcategories of EGUs?
Code of Federal Regulations, 2012 CFR
2012-07-01
... coal or gasified solid oil-derived fuel. For purposes of compliance, monitoring, recordkeeping, and...) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam... equal to 8,300 Btu/lb, and (2) EGUs designed for low rank virgin coal. (b) Oil-fired EGUs are...
40 CFR Table 8 to Subpart Uuuuu of... - Reporting Requirements
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility... period. If there were no periods during which the CMSs, including continuous emissions monitoring system, and operating parameter monitoring systems, were out-of-control as specified in § 63.8(c)(7), a...
40 CFR 63.9990 - What are the subcategories of EGUs?
Code of Federal Regulations, 2013 CFR
2013-07-01
... coal or gasified solid oil-derived fuel. For purposes of compliance, monitoring, recordkeeping, and...) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam... equal to 8,300 Btu/lb, and (2) EGUs designed for low rank virgin coal. (b) Oil-fired EGUs are...
40 CFR Table 8 to Subpart Uuuuu of... - Reporting Requirements
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility... period. If there were no periods during which the CMSs, including continuous emissions monitoring system, and operating parameter monitoring systems, were out-of-control as specified in § 63.8(c)(7), a...
40 CFR 63.9990 - What are the subcategories of EGUs?
Code of Federal Regulations, 2014 CFR
2014-07-01
... coal or gasified solid oil-derived fuel. For purposes of compliance, monitoring, recordkeeping, and...) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam... equal to 8,300 Btu/lb, and (2) EGUs designed for low rank virgin coal. (b) Oil-fired EGUs are...
49 CFR 174.102 - Forbidden mixed loading and storage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...
49 CFR 174.102 - Forbidden mixed loading and storage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...
49 CFR 174.102 - Forbidden mixed loading and storage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...
41 CFR 109-38.5102 - Utilization controls and practices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... hazards, particularly when mingled with other motor vehicle traffic; and (h) The use of electric vehicles..., TRANSPORTATION, AND MOTOR VEHICLES 38-MOTOR EQUIPMENT MANAGEMENT 38.51-Utilization of Motor Equipment § 109-38..., such as trip tickets or vehicle logs, or hours of use, as appropriate, showing sufficiently detailed...
41 CFR 109-38.5102 - Utilization controls and practices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... hazards, particularly when mingled with other motor vehicle traffic; and (h) The use of electric vehicles..., TRANSPORTATION, AND MOTOR VEHICLES 38-MOTOR EQUIPMENT MANAGEMENT 38.51-Utilization of Motor Equipment § 109-38..., such as trip tickets or vehicle logs, or hours of use, as appropriate, showing sufficiently detailed...
41 CFR 109-38.5102 - Utilization controls and practices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... hazards, particularly when mingled with other motor vehicle traffic; and (h) The use of electric vehicles..., TRANSPORTATION, AND MOTOR VEHICLES 38-MOTOR EQUIPMENT MANAGEMENT 38.51-Utilization of Motor Equipment § 109-38..., such as trip tickets or vehicle logs, or hours of use, as appropriate, showing sufficiently detailed...
7 CFR 3550.102 - Grant and loan purposes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... used to make general repairs and improvements to properties or to remove health and safety hazards, as...) The cost of providing special design features or equipment when necessary because of a physical... pro rata installation costs for utilities such as water, sewer, electricity, and gas for which the...
46 CFR 111.105-45 - Vessels carrying agricultural products.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...
46 CFR 111.105-45 - Vessels carrying agricultural products.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...
46 CFR 111.105-45 - Vessels carrying agricultural products.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...
46 CFR 111.105-45 - Vessels carrying agricultural products.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...
46 CFR 111.105-45 - Vessels carrying agricultural products.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...
30 CFR 77.513 - Insulating mats at power switches.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Insulating mats at power switches. 77.513... COAL MINES Electrical Equipment-General § 77.513 Insulating mats at power switches. Dry wooden... switchboards and power-control switches where shock hazards exist. However, metal plates on which a person...
30 CFR 77.513 - Insulating mats at power switches.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Insulating mats at power switches. 77.513... COAL MINES Electrical Equipment-General § 77.513 Insulating mats at power switches. Dry wooden... switchboards and power-control switches where shock hazards exist. However, metal plates on which a person...
30 CFR 77.513 - Insulating mats at power switches.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Insulating mats at power switches. 77.513... COAL MINES Electrical Equipment-General § 77.513 Insulating mats at power switches. Dry wooden... switchboards and power-control switches where shock hazards exist. However, metal plates on which a person...
30 CFR 77.513 - Insulating mats at power switches.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Insulating mats at power switches. 77.513... COAL MINES Electrical Equipment-General § 77.513 Insulating mats at power switches. Dry wooden... switchboards and power-control switches where shock hazards exist. However, metal plates on which a person...
30 CFR 77.513 - Insulating mats at power switches.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Insulating mats at power switches. 77.513... COAL MINES Electrical Equipment-General § 77.513 Insulating mats at power switches. Dry wooden... switchboards and power-control switches where shock hazards exist. However, metal plates on which a person...
46 CFR 111.105-37 - Flammable anesthetics.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Flammable anesthetics. 111.105-37 Section 111.105-37...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-37 Flammable anesthetics. Each electric installation where a flammable anesthetic is used or stored must meet NFPA 99 (incorporated by reference, see 46 CFR...
46 CFR 111.105-37 - Flammable anesthetics.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Flammable anesthetics. 111.105-37 Section 111.105-37...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-37 Flammable anesthetics. Each electric installation where a flammable anesthetic is used or stored must meet NFPA 99 (incorporated by reference, see 46 CFR...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-28
... the emissions of hazardous air pollutants (HAPs) released from coal-burning electric generating units...-based standard for reducing HAP emissions. EPA is developing a draft risk assessment for mercury, entitled Technical Support Document: National- Scale Mercury Risk Assessment. This draft assessment...
Van den Engh, G.
1995-11-07
A Faraday cage is described which encloses the flow chamber of a cytometer. Ground planes associated with each field deflection plate inhibit electric fields from varying the charge on designated events/droplets and further concentrates. They also increase forces applied to a passing charged event for accurate focus while concomitantly inhibiting a potential shock hazard. 4 figs.
Hazardous Waste Cleanup: General Electric - Hudson Falls in Hudson Falls, New York
This 25-acre site is within an area of residential and industrial zoning in the Village of Hudson Falls. The site is generally flat, but has a near-vertical drop to the Hudson River along its western boundary. The facility has been divided into four areas
49 CFR 174.102 - Forbidden mixed loading and storage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...
49 CFR 174.102 - Forbidden mixed loading and storage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... same rail car. Additionally, they may not be transported or loaded in the same rail car or stored on carrier property with charged electric storage batteries or with any hazardous material for which a... (explosive) materials or any other material in a placarded and certified car containing a shipment of...
76 FR 22447 - Office of Hazardous Materials Safety; Notice of Application for Special Permits
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-21
... Mohawk Electrical. 49 CFR 173.62.... To authorize the transportation in commerce of three (3) Mines, 1.1D... ethylene 173.31(e)(2)(ii) oxide in a DOT , 173.314, and 105J400W tank car 173.323(c)(ii). with a maximum...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2013 CFR
2013-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2011 CFR
2011-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2012 CFR
2012-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2014 CFR
2014-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
40 CFR 265.17 - General requirements for ignitable, reactive, or incompatible wastes.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., smoking, cutting and welding, hot surfaces, frictional heat, sparks (static, electrical, or mechanical... reactive waste is being handled, the owner or operator must confine smoking and open flame to specially designated locations. “No Smoking” signs must be conspicuously placed wherever there is a hazard from...
40 CFR 265.17 - General requirements for ignitable, reactive, or incompatible wastes.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., smoking, cutting and welding, hot surfaces, frictional heat, sparks (static, electrical, or mechanical... reactive waste is being handled, the owner or operator must confine smoking and open flame to specially designated locations. “No Smoking” signs must be conspicuously placed wherever there is a hazard from...
40 CFR 265.17 - General requirements for ignitable, reactive, or incompatible wastes.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., smoking, cutting and welding, hot surfaces, frictional heat, sparks (static, electrical, or mechanical... reactive waste is being handled, the owner or operator must confine smoking and open flame to specially designated locations. “No Smoking” signs must be conspicuously placed wherever there is a hazard from...
46 CFR 183.530 - Hazardous areas.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a... intrinsically safe system. (b) Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system. (c) Explosion-proof...
ORGANIC SULFUR AND HAP REMOVAL FROM COAL USING HYDROTHERMAL TREATMENT. (R827649C001)
Coal is still the major source of power for electrical generation worldwide and will continue to be in
the foreseeable future. However, the inorganic elements in coal that qualify as hazardous emissions
upon combustion of the coal become an increasingly important concern. P...
46 CFR 111.105-37 - Flammable anesthetics.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Flammable anesthetics. 111.105-37 Section 111.105-37...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-37 Flammable anesthetics. Each electric installation where a flammable anesthetic is used or stored must meet NFPA 99 (incorporated by reference, see 46 CFR...
46 CFR 111.105-37 - Flammable anesthetics.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Flammable anesthetics. 111.105-37 Section 111.105-37...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-37 Flammable anesthetics. Each electric installation where a flammable anesthetic is used or stored must meet NFPA 99 (incorporated by reference, see 46 CFR...
46 CFR 111.105-37 - Flammable anesthetics.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Flammable anesthetics. 111.105-37 Section 111.105-37...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-37 Flammable anesthetics. Each electric installation where a flammable anesthetic is used or stored must meet NFPA 99 (incorporated by reference, see 46 CFR...
van den Engh, Ger
1995-01-01
A Faraday cage enclosing the flow chamber of a cytometer and ground planes associated with each field deflection plate in concert therewith inhibit electric fields from varying the charge on designated events/droplets and further concentrates and increases forces applied to a charged event passing therethrough for accurate focus thereof while concomitantly inhibiting a potential shock hazard.