47 CFR 51.319 - Specific unbundling requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... copper loop and a second competitive LEC provides digital subscriber line service over the high frequency portion of that same loop. The high frequency portion of the loop consists of the frequency range on the... complete transmission path on the high frequency range between the incumbent LEC's distribution frame (or...
47 CFR 51.319 - Specific unbundling requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... copper loop and a second competitive LEC provides digital subscriber line service over the high frequency portion of that same loop. The high frequency portion of the loop consists of the frequency range on the... complete transmission path on the high frequency range between the incumbent LEC's distribution frame (or...
Dual frequency feed system for the CTS communications link characterization experiment
NASA Technical Reports Server (NTRS)
Gill, G. J.
1976-01-01
The developing, testing and installation of a dual frequency feed assembly were described. The feed has been designed to receive signals in the frequency range 11.7 to 12.2 GHz and transmit signals in the frequency range 14.12 GHz plus or minus 250 MHz. Complete performance data of the feed alone and installed in the 15 foot antenna is included herein. Drawings and descriptive information of the feed assembly are also given.
Flight phasemeter on the Laser Ranging Interferometer on the GRACE Follow-On mission
NASA Astrophysics Data System (ADS)
Bachman, B.; de Vine, G.; Dickson, J.; Dubovitsky, S.; Liu, J.; Klipstein, W.; McKenzie, K.; Spero, R.; Sutton, A.; Ware, B.; Woodruff, C.
2017-05-01
As the first inter-spacecraft laser interferometer, the Laser Ranging Interferometer (LRI) on the GRACE Follow-On Mission will demonstrate interferometry technology relevant to the LISA mission. This paper focuses on the completed LRI Laser Ranging Processor (LRP), which includes heterodyne signal phase tracking at μ {{cycle/}}\\sqrt{{{Hz}}} precision, differential wavefront sensing, offset frequency phase locking and Pound-Drever-Hall laser stabilization. The LRI design has characteristics that are similar to those for LISA: 1064 nm NPRO laser source, science bandwidth in the mHz range, MHz-range intermediate frequency and Doppler shift, detected optical power of tens of picoWatts. Laser frequency stabilization has been demonstrated at a level below 30{{Hz/}}\\sqrt{{{Hz}}}, better than the LISA requirement of 300{{Hz/}}\\sqrt{{{Hz}}}. The LRP has completed all performance testing and environmental qualification and has been delivered to the GRACE Follow-On spacecraft. The LRI is poised to test the LISA techniques of tone-assisted time delay interferometry and arm-locking. GRACE Follow-On launches in 2017.
High current nonlinear transmission line based electron beam driver
NASA Astrophysics Data System (ADS)
Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.
2017-10-01
A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).
Application of a hybrid computer to sweep frequency data processing
NASA Technical Reports Server (NTRS)
Milner, E. J.; Bruton, W. M.
1973-01-01
A hybrid computer program is presented which can process as many as 10 channels of sweep frequency data simultaneously. The program needs only the sine sweep signal used to drive the system, and its correponding quadrature component, to process the data. It can handle a maximum frequency range of 0.5 to 500 hertz. Magnitude and phase are calculated at logarithmically spaced points covering the frequency range of interest. When the sweep is completed, these results are stored in digital form. Thus, a tabular listing and/or a plot of any processed data channel or the transfer function relating any two of them is immediately available.
NASA Astrophysics Data System (ADS)
Ji, Zhan-Huai; Yan, Sheng-Gang
2017-12-01
This paper presents an analytical study of the complete transform of improved Gabor wavelets (IGWs), and discusses its application to the processing and interpretation of seismic signals. The complete Gabor wavelet transform has the following properties. First, unlike the conventional transform, the improved Gabor wavelet transform (IGWT) maps time domain signals to the time-frequency domain instead of the time-scale domain. Second, the IGW's dominant frequency is fixed, so the transform can perform signal frequency division, where the dominant frequency components of the extracted sub-band signal carry essentially the same information as the corresponding components of the original signal, and the subband signal bandwidth can be regulated effectively by the transform's resolution factor. Third, a time-frequency filter consisting of an IGWT and its inverse transform can accurately locate target areas in the time-frequency field and perform filtering in a given time-frequency range. The complete IGW transform's properties are investigated using simulation experiments and test cases, showing positive results for seismic signal processing and interpretation, such as enhancing seismic signal resolution, permitting signal frequency division, and allowing small faults to be identified.
A Completely Solid-State Tunable Ti:Sapphire Laser System
NASA Technical Reports Server (NTRS)
Guerra, David V.; Coyle, D. Barry; Krebs, Danny J.
1994-01-01
Compact, completely solid-state tunable pulsed laser system passively cooled developed for potential employment in aircraft and sounding-rocket lidar experiments. Ti:sapphire based laser system pumped with frequency-doubled diode-pumped Nd:YAG. Rugged, self-contained system extremely flexible and provides pulsed output at specific frequencies with low input-power requirements. In-situ measurements enables scientists to study upper-atmosphere dynamics. Tuning range easily extended to bands between 650-950 nm in order to study other atmospheric constituents.
Parthasarathy, Aravindakshan; Bartlett, Edward
2012-07-01
Auditory brainstem responses (ABRs), and envelope and frequency following responses (EFRs and FFRs) are widely used to study aberrant auditory processing in conditions such as aging. We have previously reported age-related deficits in auditory processing for rapid amplitude modulation (AM) frequencies using EFRs recorded from a single channel. However, sensitive testing of EFRs along a wide range of modulation frequencies is required to gain a more complete understanding of the auditory processing deficits. In this study, ABRs and EFRs were recorded simultaneously from two electrode configurations in young and old Fischer-344 rats, a common auditory aging model. Analysis shows that the two channels respond most sensitively to complementary AM frequencies. Channel 1, recorded from Fz to mastoid, responds better to faster AM frequencies in the 100-700 Hz range of frequencies, while Channel 2, recorded from the inter-aural line to the mastoid, responds better to slower AM frequencies in the 16-100 Hz range. Simultaneous recording of Channels 1 and 2 using AM stimuli with varying sound levels and modulation depths show that age-related deficits in temporal processing are not present at slower AM frequencies but only at more rapid ones, which would not have been apparent recording from either channel alone. Comparison of EFRs between un-anesthetized and isoflurane-anesthetized recordings in young animals, as well as comparison with previously published ABR waveforms, suggests that the generators of Channel 1 may emphasize more caudal brainstem structures while those of Channel 2 may emphasize more rostral auditory nuclei including the inferior colliculus and the forebrain, with the boundary of separation potentially along the cochlear nucleus/superior olivary complex. Simultaneous two-channel recording of EFRs help to give a more complete understanding of the properties of auditory temporal processing over a wide range of modulation frequencies which is useful in understanding neural representations of sound stimuli in normal, developmental or pathological conditions. Copyright © 2012 Elsevier B.V. All rights reserved.
Xiang, Ying; Zhou, Meng-jie; Xu, Ming-Ya; Salamon, Péter; Éber, Nándor; Buka, Ágnes
2015-04-01
Electric-field-induced patterns of diverse morphology have been observed over a wide frequency range in a recently synthesized bent-core nematic (BCN) liquid crystal. At low frequencies (up to ∼25 Hz), the BCN exhibited unusual polarity-dependent patterns. When the amplitude of the ac field was enhanced, these two time-asymmetrical patterns turned into time-symmetrical prewavylike stripes. At ac frequencies in the middle-frequency range (∼50-3000 Hz), zigzag patterns were detected whose obliqueness varied with the frequency. Finally, if the frequency was increased above 3 kHz, the zigzag pattern was replaced by another, prewavylike pattern, whose threshold voltage depended on the frequency; however, the wave vector did not. For a more complete characterization, material parameters such as elastic constants, dielectric permittivities, and the anisotropy of the diamagnetic susceptibility were also determined.
Molecular Electronic Angular Motion Transducer Broad Band Self-Noise.
Zaitsev, Dmitry; Agafonov, Vadim; Egorov, Egor; Antonov, Alexander; Shabalina, Anna
2015-11-20
Modern molecular electronic transfer (MET) angular motion sensors combine high technical characteristics with low cost. Self-noise is one of the key characteristics which determine applications for MET sensors. However, until the present there has not been a model describing the sensor noise in the complete operating frequency range. The present work reports the results of an experimental study of the self-noise level of such sensors in the frequency range of 0.01-200 Hz. Based on the experimental data, a theoretical model is developed. According to the model, self-noise is conditioned by thermal hydrodynamic fluctuations of the operating fluid flow in the frequency range of 0.01-2 Hz. At the frequency range of 2-100 Hz, the noise power spectral density has a specific inversely proportional dependence of the power spectral density on the frequency that could be attributed to convective processes. In the high frequency range of 100-200 Hz, the noise is conditioned by the voltage noise of the electronics module input stage operational amplifiers and is heavily reliant to the sensor electrical impedance. The presented results allow a deeper understanding of the molecular electronic sensor noise nature to suggest the ways to reduce it.
Radio synthesis imaging during the GRO solar campaign
NASA Technical Reports Server (NTRS)
Gary, Dale E.
1992-01-01
The Owens Valley (OVRO) Solar Array was recently expanded to 5 antennas. Using frequency synthesis, the 5-element OVRO Solar Array has up to 450 effective baselines, which can be employed as necessary to make maps at frequencies in the range 1 to 18 GHz. Fortuitously, the last of the 5 antennas was completed and brought into operation on 7 Jun., just in time for the Gamma Ray Observatory (GRO)/Max 1991 observing campaign. Many events were observed jointly with OVRO and the BATSE experiment on GRO, including the six larger events that are presented in tabular form. Unfortunately, the X flares that occurred during the campaign all occurred outside the OVRO time range. The UV coverage of the newly expanded solar array, combined with frequency synthesis, should give a more complete view of solar flares in the microwave range by providing simultaneous spatial and spectral resolution. A promising application of MEM (maximum entropy) is also being pursued that will use smoothness criteria in both the spatial and spectral domains to give brightness temperature maps at each observed frequency (up to 45 frequencies every 10 s). Such maps can be compared directly with the theory of microwave emission to yield plasma parameters in the source - notably the number and energy distribution of electrons, for comparison with the x ray and gamma ray results from GRO.
Auditory frequency generalization in the goldfish (Carassius auratus)1
Fay, Richard R.
1970-01-01
Auditory frequency generalization in the goldfish was studied at five points within the best hearing range through the use of classical respiratory conditioning. Each experimental group received single-stimulus conditioning sessions at one of five stimulus frequencies (100, 200, 400, 800, and 1600 Hz), and were subsequently tested for generalization at eight neighboring frequencies. All stimuli were presented 30 db above absolute threshold. Significant generalization decrements were found for all subjects. For the subjects conditioned in the range between 100 and 800 Hz, a nearly complete failure to generalize was found at one octave above and below the training frequency. The subjects conditioned at 1600 Hz produced relatively more flat gradients between 900 and 2000 Hz. The widths of the generalization gradients, expressed in Hz, increased as a power function of frequency with a slope greater than one. PMID:16811481
Ibsen, Stuart D; Nachtigall, Paul E; Krause-Nehring, Jacqueline; Kloepper, Laura; Breese, Marlee; Li, Songhai; Vlachos, Stephanie
2012-08-01
A two-dimensional array of 16 hydrophones was created to map the spatial distribution of different frequencies within the echolocation beam of a Tursiops truncatus and a Pseudorca crassidens. It was previously shown that both the Tursiops and Pseudorca only paid attention to frequencies between 29 and 42 kHz while echolocating. Both individuals tightly focused the 30 kHz frequency and the spatial location of the focus was consistently pointed toward the target. At 50 kHz the beam was less focused and less precisely pointed at the target. At 100 kHz the focus was often completely lost and was not pointed at the target. This indicates that these individuals actively focused the beam toward the target only in the frequency range they paid attention to. Frequencies outside this range were left unfocused and undirected. This focusing was probably achieved through sensorimotor control of the melon morphology and nasal air sacs. This indicates that both morphologically different species can control the spatial distribution of different frequency ranges within the echolocation beam to create consistent ensonation of desired targets.
Molecular Electronic Angular Motion Transducer Broad Band Self-Noise
Zaitsev, Dmitry; Agafonov, Vadim; Egorov, Egor; Antonov, Alexander; Shabalina, Anna
2015-01-01
Modern molecular electronic transfer (MET) angular motion sensors combine high technical characteristics with low cost. Self-noise is one of the key characteristics which determine applications for MET sensors. However, until the present there has not been a model describing the sensor noise in the complete operating frequency range. The present work reports the results of an experimental study of the self-noise level of such sensors in the frequency range of 0.01–200 Hz. Based on the experimental data, a theoretical model is developed. According to the model, self-noise is conditioned by thermal hydrodynamic fluctuations of the operating fluid flow in the frequency range of 0.01–2 Hz. At the frequency range of 2–100 Hz, the noise power spectral density has a specific inversely proportional dependence of the power spectral density on the frequency that could be attributed to convective processes. In the high frequency range of 100–200 Hz, the noise is conditioned by the voltage noise of the electronics module input stage operational amplifiers and is heavily reliant to the sensor electrical impedance. The presented results allow a deeper understanding of the molecular electronic sensor noise nature to suggest the ways to reduce it. PMID:26610502
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-04
... in our files, a personal communication (cited ``D. Faulkner, V. Marquez-Waller pers. comm. on 4/16/08... frequency may result in altered vegetation structure or type conversion throughout the range (Keeley and... require mature R. crocea to complete their lifecycle; therefore, increased fire frequency may reduce...
Kiwanuka, S N; Astrøm, A N; Trovik, T A
2006-10-01
This study assessed the reproducibility and relative validity of an eight-item self-administered food frequency questionnaire (FFQ) on intake of sugared snacks in Ugandan schoolchildren. A 5-day precoded food behaviour checklist (FBC) was used as validation criteria. Sociodemographic correlates of a sum frequency sugar score were explored. The study was conducted in Kampala, Uganda, in 2004. Six hundred and fourteen schoolchildren (mean age 12.4 years) completed the FFQ on cakes/biscuits, chocolate, ice sticks, soft drinks, coffee, tea, sugared desserts and sweets/candies at school. They were examined clinically for dental caries. Forty students completed the FFQ twice, 1 week apart and 325 students completed the 5 day FBC at school. The mean decayed, missing and filled tooth index score was 0.98 (SD 1.6, range 0-15). Reproducibility scores (Cohen's kappa) for the sugar items ranged from 0.17 (ice sticks) to 0.55 (biscuits). No differences were seen between the average intakes at test and retest. Higher intake was reported in FFQ than in FBC across all sugar items. Crude agreement between students reporting intake at least 3-5 times a week/less than three times a week ranged from 50% to 55% (e.g. biscuits, chocolate) to 87% (tea). Spearman's correlation coefficients ranged from 0.14 (desserts) to 0.27 (sweets). anova revealed significant increase (P = 0.001) in the mean FBC sum scores by increasing quartiles of the FFQ sum scores. The average sum FFQ sugar scores were higher in girls than in boys and higher in older than in younger students. Fair reproducibility was established for the FFQ sugar items. The FFQ was acceptable in classifying individuals into broad categories of low and high sugar consumption.
Pichard, Hélène; Richoux, Olivier; Groby, Jean-Philippe
2012-10-01
The propagation of audible acoustic waves in two-dimensional square lattice tunable sonic crystals (SC) made of square cross-section infinitely rigid rods embedded in air is investigated experimentally. The band structure is calculated with the plane wave expansion (PWE) method and compared with experimental measurements carried out on a finite extend structure of 200 cm width, 70 cm depth and 15 cm height. The structure is made of square inclusions of 5 cm side with a periodicity of L = 7.5 cm placed inbetween two rigid plates. The existence of tunable complete band gaps in the audible frequency range is demonstrated experimentally by rotating the scatterers around their vertical axis. Negative refraction is then analyzed by use of the anisotropy of the equi-frequency surface (EFS) in the first band and of a finite difference time domain (FDTD) method. Experimental results finally show negative refraction in the audible frequency range.
Frequency Diverse Array Receiver Architectures
2015-06-29
completely associated with FDA, the Hybrid MIMO phased array (HMPAR) concept presented in [18] developed the basic beam patern synthesis theory for an...20], that analyzed beam paterns of chirp waveforms with slightly 6 different starting frequencies. In [21] and [11] they investigated using FDA for...forward-looking radar GMTI benefits. This research showed the ability of the range-dependent energy distribution characteristics of the FDA beam patern
An Optical Frequency Comb Tied to GPS for Laser Frequency/Wavelength Calibration
Stone, Jack A.; Egan, Patrick
2010-01-01
Optical frequency combs can be employed over a broad spectral range to calibrate laser frequency or vacuum wavelength. This article describes procedures and techniques utilized in the Precision Engineering Division of NIST (National Institute of Standards and Technology) for comb-based calibration of laser wavelength, including a discussion of ancillary measurements such as determining the mode order. The underlying purpose of these calibrations is to provide traceable standards in support of length measurement. The relative uncertainty needed to fulfill this goal is typically 10−8 and never below 10−12, very modest requirements compared to the capabilities of comb-based frequency metrology. In this accuracy range the Global Positioning System (GPS) serves as an excellent frequency reference that can provide the traceable underpinning of the measurement. This article describes techniques that can be used to completely characterize measurement errors in a GPS-based comb system and thus achieve full confidence in measurement results. PMID:27134794
Prospects for Future Synergies Between SKA and AtLAST
NASA Astrophysics Data System (ADS)
Wagg, Jeff
2018-01-01
The Square Kilometre Array will be the next major global radio astronomy observatory. Being built in two phases, the first phase will consist of a low frequency array in Australia and a mid to high frequency array of dishes in the Karoo of South Africa. The design of SKA1 is nearly complete with the expectation that construction should begin within the next two years. A significant fraction of the observing time on both SKA1-MID and SKA1-LOW will likely be devoted to large survey programmes covering a broad range of science objectives. Given the timeline for these SKA1 programmes to be completed, it is anticipated that they could naturally complement future high frequency surveys using AtLAST. I will highlight a few areas where such synergies should exist.
Jun, Changsu; Villiger, Martin; Oh, Wang-Yuhl; Bouma, Brett E.
2014-01-01
Innovations in laser engineering have yielded several novel configurations for high repetition rate, broad sweep range, and long coherence length wavelength swept lasers. Although these lasers have enabled high performance frequency-domain optical coherence tomography, they are typically complicated and costly and many require access to proprietary materials or devices. Here, we demonstrate a simplified ring resonator configuration that is straightforward to construct from readily available materials at a low total cost. It was enabled by an insight regarding the significance of isolation against bidirectional operation and by configuring the sweep range of the intracavity filter to exceed its free spectral range. The design can easily be optimized to meet a range of operating specifications while yielding robust and stable performance. As an example, we demonstrate 240 kHz operation with 125 nm sweep range and >70 mW of average output power and demonstrate high quality frequency domain OCT imaging. The complete component list and directions for assembly of the laser are posted on-line at www.octresearch.org. PMID:25401614
When ottoman is easier than chair: an inverse frequency effect in jargon aphasia.
Marshall, J; Pring, T; Chiat, S; Robson, J
2001-02-01
This paper presents evidence of an inverse frequency effect in jargon aphasia. The subject (JP) showed a pre-disposition for low frequency word production on a range of tasks, including picture naming, sentence completion and naming in categories. Her real word errors were also striking, in that these tended to be lower in frequency than the target. Reading data suggested that the inverse frequency effect was present only when production was semantically mediated. It was therefore hypothesised that the effect was at least partly due to the semantic characteristics of low frequency items. Some support for this was obtained from a comprehension task showing that JP's understanding of low frequency terms, which she often produced as errors, was superior to her understanding of high frequency terms. Possible explanations for these findings are considered.
Narrow band quantitative and multivariate electroencephalogram analysis of peri-adolescent period.
Martinez, E I Rodríguez; Barriga-Paulino, C I; Zapata, M I; Chinchilla, C; López-Jiménez, A M; Gómez, C M
2012-08-24
The peri-adolescent period is a crucial developmental moment of transition from childhood to emergent adulthood. The present report analyses the differences in Power Spectrum (PS) of the Electroencephalogram (EEG) between late childhood (24 children between 8 and 13 years old) and young adulthood (24 young adults between 18 and 23 years old). The narrow band analysis of the Electroencephalogram was computed in the frequency range of 0-20 Hz. The analysis of mean and variance suggested that six frequency ranges presented a different rate of maturation at these ages, namely: low delta, delta-theta, low alpha, high alpha, low beta and high beta. For most of these bands the maturation seems to occur later in anterior sites than posterior sites. Correlational analysis showed a lower pattern of correlation between different frequencies in children than in young adults, suggesting a certain asynchrony in the maturation of different rhythms. The topographical analysis revealed similar topographies of the different rhythms in children and young adults. Principal Component Analysis (PCA) demonstrated the same internal structure for the Electroencephalogram of both age groups. Principal Component Analysis allowed to separate four subcomponents in the alpha range. All these subcomponents peaked at a lower frequency in children than in young adults. The present approaches complement and solve some of the incertitudes when the classical brain broad rhythm analysis is applied. Children have a higher absolute power than young adults for frequency ranges between 0-20 Hz, the correlation of Power Spectrum (PS) with age and the variance age comparison showed that there are six ranges of frequencies that can distinguish the level of EEG maturation in children and adults. The establishment of maturational order of different frequencies and its possible maturational interdependence would require a complete series including all the different ages.
Method for network analyzation and apparatus
Bracht, Roger B.; Pasquale, Regina V.
2001-01-01
A portable network analyzer and method having multiple channel transmit and receive capability for real-time monitoring of processes which maintains phase integrity, requires low power, is adapted to provide full vector analysis, provides output frequencies of up to 62.5 MHz and provides fine sensitivity frequency resolution. The present invention includes a multi-channel means for transmitting and a multi-channel means for receiving, both in electrical communication with a software means for controlling. The means for controlling is programmed to provide a signal to a system under investigation which steps consecutively over a range of predetermined frequencies. The resulting received signal from the system provides complete time domain response information by executing a frequency transform of the magnitude and phase information acquired at each frequency step.
FDTD computation of human eye exposure to ultra-wideband electromagnetic pulses.
Simicevic, Neven
2008-03-21
With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29 and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of 0.1 mm and an arbitrary precision in the description of its dielectric properties in terms of the Debye model. New results show that the interaction of UWB pulses with the eye tissues exhibits the same properties as the interaction of the continuous electromagnetic waves (CWs) with the frequencies from the pulse's frequency spectrum. It is also shown that under the same exposure conditions the exposure to UWB pulses is from one to many orders of magnitude safer than the exposure to CW.
Ladar imaging detection of salient map based on PWVD and Rényi entropy
NASA Astrophysics Data System (ADS)
Xu, Yuannan; Zhao, Yuan; Deng, Rong; Dong, Yanbing
2013-10-01
Spatial-frequency information of a given image can be extracted by associating the grey-level spatial data with one of the well-known spatial/spatial-frequency distributions. The Wigner-Ville distribution (WVD) has a good characteristic that the images can be represented in spatial/spatial-frequency domains. For intensity and range images of ladar, through the pseudo Wigner-Ville distribution (PWVD) using one or two dimension window, the statistical property of Rényi entropy is studied. We also analyzed the change of Rényi entropy's statistical property in the ladar intensity and range images when the man-made objects appear. From this foundation, a novel method for generating saliency map based on PWVD and Rényi entropy is proposed. After that, target detection is completed when the saliency map is segmented using a simple and convenient threshold method. For the ladar intensity and range images, experimental results show the proposed method can effectively detect the military vehicles from complex earth background with low false alarm.
Automatic Locking of Laser Frequency to an Absorption Peak
NASA Technical Reports Server (NTRS)
Koch, Grady J.
2006-01-01
An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.
NASA Technical Reports Server (NTRS)
Hubeny, I.; Lanz, T.
1995-01-01
A new munerical method for computing non-Local Thermodynamic Equilibrium (non-LTE) model stellar atmospheres is presented. The method, called the hybird complete linearization/accelerated lambda iretation (CL/ALI) method, combines advantages of both its constituents. Its rate of convergence is virtually as high as for the standard CL method, while the computer time per iteration is almost as low as for the standard ALI method. The method is formulated as the standard complete lineariation, the only difference being that the radiation intensity at selected frequency points is not explicity linearized; instead, it is treated by means of the ALI approach. The scheme offers a wide spectrum of options, ranging from the full CL to the full ALI method. We deonstrate that the method works optimally if the majority of frequency points are treated in the ALI mode, while the radiation intensity at a few (typically two to 30) frequency points is explicity linearized. We show how this method can be applied to calculate metal line-blanketed non-LTE model atmospheres, by using the idea of 'superlevels' and 'superlines' introduced originally by Anderson (1989). We calculate several illustrative models taking into accont several tens of thosands of lines of Fe III to Fe IV and show that the hybrid CL/ALI method provides a robust method for calculating non-LTE line-blanketed model atmospheres for a wide range of stellar parameters. The results for individual stellar types will be presented in subsequent papers in this series.
Full band all-sky search for periodic gravitational waves in the O1 LIGO data
NASA Astrophysics Data System (ADS)
Abbott, B. P.; Abbott, R.; Abbott, T. D.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Afrough, M.; Agarwal, B.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Allen, B.; Allen, G.; Allocca, A.; Altin, P. A.; Amato, A.; Ananyeva, A.; Anderson, S. B.; Anderson, W. G.; Angelova, S. V.; Antier, S.; Appert, S.; Arai, K.; Araya, M. C.; Areeda, J. S.; Arnaud, N.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Atallah, D. V.; Aufmuth, P.; Aulbert, C.; AultONeal, K.; Austin, C.; Avila-Alvarez, A.; Babak, S.; Bacon, P.; Bader, M. K. M.; Bae, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Banagiri, S.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barkett, K.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bawaj, M.; Bayley, J. C.; Bazzan, M.; Bécsy, B.; Beer, C.; Bejger, M.; Belahcene, I.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Bero, J. J.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Billman, C. R.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Biscoveanu, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackman, J.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Bode, N.; Boer, M.; Bogaert, G.; Bohe, A.; Bondu, F.; Bonilla, E.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bossie, K.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Bustillo, J. Calderón; Callister, T. A.; Calloni, E.; Camp, J. B.; Canepa, M.; Canizares, P.; Cannon, K. C.; Cao, H.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Carney, M. F.; Casanueva Diaz, J.; Casentini, C.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerdá-Durán, P.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chase, E.; Chassande-Mottin, E.; Chatterjee, D.; Cheeseboro, B. D.; Chen, H. Y.; Chen, X.; Chen, Y.; Cheng, H.-P.; Chia, H. Y.; Chincarini, A.; Chiummo, A.; Chmiel, T.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, A. J. K.; Chua, S.; Chung, A. K. W.; Chung, S.; Ciani, G.; Ciecielag, P.; Ciolfi, R.; Cirelli, C. E.; Cirone, A.; Clara, F.; Clark, J. A.; Clearwater, P.; Cleva, F.; Cocchieri, C.; Coccia, E.; Cohadon, P.-F.; Cohen, D.; Colla, A.; Collette, C. G.; Cominsky, L. R.; Constancio, M.; Conti, L.; Cooper, S. J.; Corban, P.; Corbitt, T. R.; Cordero-Carrión, I.; Corley, K. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, E. T.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J.-P.; Countryman, S. T.; Couvares, P.; Covas, P. B.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cullen, T. J.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Dálya, G.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dasgupta, A.; Da Silva Costa, C. F.; Dattilo, V.; Dave, I.; Davier, M.; Davis, D.; Daw, E. J.; Day, B.; De, S.; DeBra, D.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Demos, N.; Denker, T.; Dent, T.; De Pietri, R.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; De Rossi, C.; DeSalvo, R.; de Varona, O.; Devenson, J.; Dhurandhar, S.; Díaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Renzo, F.; Doctor, Z.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorosh, O.; Dorrington, I.; Douglas, R.; Dovale Álvarez, M.; Downes, T. P.; Drago, M.; Dreissigacker, C.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dupej, P.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Eisenstein, R. A.; Essick, R. C.; Estevez, D.; Etienne, Z. B.; Etzel, T.; Evans, M.; Evans, T. M.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E. J.; Favata, M.; Fays, M.; Fee, C.; Fehrmann, H.; Feicht, J.; Fejer, M. M.; Fernandez-Galiana, A.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Finstad, D.; Fiori, I.; Fiorucci, D.; Fishbach, M.; Fisher, R. P.; Fitz-Axen, M.; Flaminio, R.; Fletcher, M.; Fong, H.; Font, J. A.; Forsyth, P. W. F.; Forsyth, S. S.; Fournier, J.-D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fries, E. M.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H.; Gadre, B. U.; Gaebel, S. M.; Gair, J. R.; Gammaitoni, L.; Ganija, M. R.; Gaonkar, S. G.; Garcia-Quiros, C.; Garufi, F.; Gateley, B.; Gaudio, S.; Gaur, G.; Gayathri, V.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, D.; George, J.; Gergely, L.; Germain, V.; Ghonge, S.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glover, L.; Goetz, E.; Goetz, R.; Gomes, S.; Goncharov, B.; González, G.; Gonzalez Castro, J. M.; Gopakumar, A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Gretarsson, E. M.; Groot, P.; Grote, H.; Grunewald, S.; Gruning, P.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Halim, O.; Hall, B. R.; Hall, E. D.; Hamilton, E. Z.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hannuksela, O. A.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Haster, C.-J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hinderer, T.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Horst, C.; Hough, J.; Houston, E. A.; Howell, E. J.; Hreibi, A.; Hu, Y. M.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Inta, R.; Intini, G.; Isa, H. N.; Isac, J.-M.; Isi, M.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Junker, J.; Kalaghatgi, C. V.; Kalogera, V.; Kamai, B.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Katolik, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kawabe, K.; Kéfélian, F.; Keitel, D.; Kemball, A. J.; Kennedy, R.; Kent, C.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J. C.; Kim, K.; Kim, W.; Kim, W. S.; Kim, Y.-M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kinley-Hanlon, M.; Kirchhoff, R.; Kissel, J. S.; Kleybolte, L.; Klimenko, S.; Knowles, T. D.; Koch, P.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Krämer, C.; Kringel, V.; Krishnan, B.; Królak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kumar, S.; Kuo, L.; Kutynia, A.; Kwang, S.; Lackey, B. D.; Lai, K. H.; Landry, M.; Lang, R. N.; Lange, J.; Lantz, B.; Lanza, R. K.; Lartaux-Vollard, A.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Lee, K.; Lehmann, J.; Lenon, A.; Leonardi, M.; Leroy, N.; Letendre, N.; Levin, Y.; Li, T. G. F.; Linker, S. D.; Littenberg, T. B.; Liu, J.; Lo, R. K. L.; Lockerbie, N. A.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lovelace, G.; Lück, H.; Lumaca, D.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macas, R.; Macfoy, S.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña Hernandez, I.; Magaña-Sandoval, F.; Magaña Zertuche, L.; Magee, R. M.; Majorana, E.; Maksimovic, I.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markakis, C.; Markosyan, A. S.; Markowitz, A.; Maros, E.; Marquina, A.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D. V.; Mason, K.; Massera, E.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matas, A.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McCuller, L.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McNeill, L.; McRae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Mejuto-Villa, E.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, B. B.; Miller, J.; Millhouse, M.; Milovich-Goff, M. C.; Minazzoli, O.; Minenkov, Y.; Ming, J.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moffa, D.; Moggi, A.; Mogushi, K.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Muñiz, E. A.; Muratore, M.; Murray, P. G.; Napier, K.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Neilson, J.; Nelemans, G.; Nelson, T. J. N.; Nery, M.; Neunzert, A.; Nevin, L.; Newport, J. M.; Newton, G.; Ng, K. Y.; Nguyen, T. T.; Nichols, D.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Noack, A.; Nocera, F.; Nolting, D.; North, C.; Nuttall, L. K.; Oberling, J.; O'Dea, G. D.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Okada, M. A.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; Ormiston, R.; Ortega, L. F.; O'Shaughnessy, R.; Ossokine, S.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pace, A. E.; Page, J.; Page, M. A.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, Howard; Pan, Huang-Wei; Pang, B.; Pang, P. T. H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Parida, A.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patil, M.; Patricelli, B.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perez, C. J.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pirello, M.; Pisarski, A.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Porter, E. K.; Post, A.; Powell, J.; Prasad, J.; Pratt, J. W. W.; Pratten, G.; Predoi, V.; Prestegard, T.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qi, H.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rajbhandari, B.; Rakhmanov, M.; Ramirez, K. E.; Ramos-Buades, A.; Rapagnani, P.; Raymond, V.; Razzano, M.; Read, J.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Ren, W.; Reyes, S. D.; Ricci, F.; Ricker, P. M.; Rieger, S.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romel, C. L.; Romie, J. H.; Rosińska, D.; Ross, M. P.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Rutins, G.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sampson, L. M.; Sanchez, E. J.; Sanchez, L. E.; Sanchis-Gual, N.; Sandberg, V.; Sanders, J. R.; Sassolas, B.; Saulson, P. R.; Sauter, O.; Savage, R. L.; Sawadsky, A.; Schale, P.; Scheel, M.; Scheuer, J.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schönbeck, A.; Schreiber, E.; Schuette, D.; Schulte, B. W.; Schutz, B. F.; Schwalbe, S. G.; Scott, J.; Scott, S. M.; Seidel, E.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D. A.; Shaffer, T. J.; Shah, A. A.; Shahriar, M. S.; Shaner, M. B.; Shao, L.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, L. P.; Singh, A.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, B.; Smith, J. R.; Smith, R. J. E.; Somala, S.; Son, E. J.; Sonnenberg, J. A.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Spencer, A. P.; Srivastava, A. K.; Staats, K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stevenson, S. P.; Stone, R.; Stops, D. J.; Strain, K. A.; Stratta, G.; Strigin, S. E.; Strunk, A.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Suresh, J.; Sutton, P. J.; Swinkels, B. L.; Szczepańczyk, M. J.; Tacca, M.; Tait, S. C.; Talbot, C.; Talukder, D.; Tanner, D. B.; Tao, D.; Tápai, M.; Taracchini, A.; Tasson, J. D.; Taylor, J. A.; Taylor, R.; Tewari, S. V.; Theeg, T.; Thies, F.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tonelli, M.; Tornasi, Z.; Torres-Forné, A.; Torrie, C. I.; Töyrä, D.; Travasso, F.; Traylor, G.; Trinastic, J.; Tringali, M. C.; Trozzo, L.; Tsang, K. W.; Tse, M.; Tso, R.; Tsukada, L.; Tsuna, D.; Tuyenbayev, D.; Ueno, K.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; Van Den Broeck, C.; Vander-Hyde, D. C.; van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Varma, V.; Vass, S.; Vasúth, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Venugopalan, G.; Verkindt, D.; Vetrano, F.; Viceré, A.; Viets, A. D.; Vinciguerra, S.; Vine, D. J.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walet, R.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, J. Z.; Wang, W. H.; Wang, Y. F.; Ward, R. L.; Warner, J.; Was, M.; Watchi, J.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wessel, E. K.; Weßels, P.; Westerweck, J.; Westphal, T.; Wette, K.; Whelan, J. T.; Whiting, B. F.; Whittle, C.; Wilken, D.; Williams, D.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Wofford, J.; Wong, W. K.; Worden, J.; Wright, J. L.; Wu, D. S.; Wysocki, D. M.; Xiao, S.; Yamamoto, H.; Yancey, C. C.; Yang, L.; Yap, M. J.; Yazback, M.; Yu, Hang; Yu, Haocun; Yvert, M.; Zadroźny, A.; Zanolin, M.; Zelenova, T.; Zendri, J.-P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, T.; Zhang, Y.-H.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, S. J.; Zhu, X. J.; Zucker, M. E.; Zweizig, J.; LIGO Scientific Collaboration; Virgo Collaboration
2018-05-01
We report on a new all-sky search for periodic gravitational waves in the frequency band 475-2000 Hz and with a frequency time derivative in the range of [-1.0 ,+0.1 ] ×1 0-8 Hz /s . Potential signals could be produced by a nearby spinning and slightly nonaxisymmetric isolated neutron star in our Galaxy. This search uses the data from Advanced LIGO's first observational run O1. No gravitational-wave signals were observed, and upper limits were placed on their strengths. For completeness, results from the separately published low-frequency search 20-475 Hz are included as well. Our lowest upper limit on worst-case (linearly polarized) strain amplitude h0 is ˜4 ×1 0-25 near 170 Hz, while at the high end of our frequency range, we achieve a worst-case upper limit of 1.3 ×1 0-24. For a circularly polarized source (most favorable orientation), the smallest upper limit obtained is ˜1.5 ×1 0-25.
Periodic components of hand acceleration/deceleration impulses during telemanipulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Draper, J.V.; Handel, S.
1994-01-01
Responsiveness is the ability of a telemanipulator to recreate user trajectories and impedance in time and space. For trajectory production, a key determinant of responsiveness is the ability of the system to accept user inputs, which are forces on the master handle generated by user hand acceleration/deceleration (a/d) impulses, and translate them into slave arm acceleration/deceleration. This paper presents observations of master controller a/d impulses during completion of a simple target acquisition task. Power spectral density functions (PSDF`s) calculated from hand controller a/d impulses were used to assess impulse waveform. The relative contributions of frequency intervals ranging up to 25more » Hz for three spatially different versions of the task were used to determine which frequencies were most important. The highest relative power was observed in frequencies between 1 Hz and 6 Hz. The key frequencies related to task difficulty were in the range from 2 Hz to 8 Hz. the results provide clues to the source of the performance inhibition.« less
Audiological manifestations in HIV-positive adults.
Matas, Carla Gentile; Angrisani, Rosanna Giaffredo; Magliaro, Fernanda Cristina Leite; Segurado, Aluisio Augusto Cotrim
2014-07-01
To characterize the findings of behavioral hearing assessment in HIV-positive individuals who received and did not receive antiretroviral treatment. This research was a cross-sectional study. The participants were 45 HIV-positive individuals (18 not exposed and 27 exposed to antiretroviral treatment) and 30 control-group individuals. All subjects completed an audiological evaluation through pure-tone audiometry, speech audiometry, and high-frequency audiometry. The hearing thresholds obtained by pure-tone audiometry were different between groups. The group that had received antiretroviral treatment had higher thresholds for the frequencies ranging from 250 to 3000 Hz compared with the control group and the group not exposed to treatment. In the range of frequencies from 4000 through 8000 Hz, the HIV-positive groups presented with higher thresholds than did the control group. The hearing thresholds determined by high-frequency audiometry were different between groups, with higher thresholds in the HIV-positive groups. HIV-positive individuals presented poorer results in pure-tone and high-frequency audiometry, suggesting impairment of the peripheral auditory pathway. Individuals who received antiretroviral treatment presented poorer results on both tests compared with individuals not exposed to antiretroviral treatment.
Sensitivity of woody carbon stocks to bark investment strategy in Neotropical savannas and forests
NASA Astrophysics Data System (ADS)
Trugman, Anna T.; Medvigy, David; Hoffmann, William A.; Pellegrini, Adam F. A.
2018-01-01
Fire frequencies are changing in Neotropical savannas and forests as a result of forest fragmentation and increasing drought. Such changes in fire regime and climate are hypothesized to destabilize tropical carbon storage, but there has been little consideration of the widespread variability in tree fire tolerance strategies. To test how aboveground carbon stocks change with fire frequency and composition of plants with different fire tolerance strategies, we update the Ecosystem Demography model 2 (ED2) with (i) a fire survivorship module based on tree bark thickness (a key fire-tolerance trait across woody plants in savannas and forests), and (ii) plant functional types representative of trees in the region. With these updates, the model is better able to predict how fire frequency affects population demography and aboveground woody carbon. Simulations illustrate that the high survival rate of thick-barked, large trees reduces carbon losses with increasing fire frequency, with high investment in bark being particularly important in reducing losses in the wettest sites. Additionally, in landscapes that frequently burn, bark investment can broaden the range of climate and fire conditions under which savannas occur by reducing the range of conditions leading to either complete tree loss or complete grass loss. These results highlight that tropical vegetation dynamics depend not only on rainfall and changing fire frequencies but also on tree fire survival strategy. Further, our results indicate that fire survival strategy is fundamentally important in regulating tree size demography in ecosystems exposed to fire, which increases the preservation of aboveground carbon stocks and the coexistence of different plant functional groups.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang; Liao, Xiao-Mei
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons.
Cheng, Liang; Wang, Shao-Hui; Peng, Kang
2017-01-01
Most citizen people are exposed daily to environmental noise at moderate levels with a short duration. The aim of the present study was to determine the effects of daily short-term exposure to moderate noise on sound level processing in the auditory midbrain. Sound processing properties of auditory midbrain neurons were recorded in anesthetized mice exposed to moderate noise (80 dB SPL, 2 h/d for 6 weeks) and were compared with those from age-matched controls. Neurons in exposed mice had a higher minimum threshold and maximum response intensity, a longer first spike latency, and a higher slope and narrower dynamic range for rate level function. However, these observed changes were greater in neurons with the best frequency within the noise exposure frequency range compared with those outside the frequency range. These sound processing properties also remained abnormal after a 12-week period of recovery in a quiet laboratory environment after completion of noise exposure. In conclusion, even daily short-term exposure to moderate noise can cause long-term impairment of sound level processing in a frequency-specific manner in auditory midbrain neurons. PMID:28589040
NASA Technical Reports Server (NTRS)
Bland, S. R.
1982-01-01
Finite difference methods for unsteady transonic flow frequency use simplified equations in which certain of the time dependent terms are omitted from the governing equations. Kernel functions are derived for two dimensional subsonic flow, and provide accurate solutions of the linearized potential equation with the same time dependent terms omitted. These solutions make possible a direct evaluation of the finite difference codes for the linear problem. Calculations with two of these low frequency kernel functions verify the accuracy of the LTRAN2 and HYTRAN2 finite difference codes. Comparisons of the low frequency kernel function results with the Possio kernel function solution of the complete linear equations indicate the adequacy of the HYTRAN approximation for frequencies in the range of interest for flutter calculations.
Drew, R; Sapir, S
1995-06-01
Nineteen trained soprano singers aged 18-30 years vocalized tasks designed to assess average speaking fundamental frequency (SFF) during spontaneous speaking and reading. Vocal range and perceptual characteristics while singing with low intensity and high frequency were also assessed, and subjects completed a survey of vocal habits/symptoms. Recorded signals were digitized prior to being analyzed for SFF using the Kay Computerized Speech Lab program. Subjects were assigned to a normal voice or impaired voice group based on ratings of perceptual tasks and survey results. Data analysis showed group differences in mean SFF, no differences in vocal range, higher mean SFF values for reading than speaking, and 58% ability to perceive speaking in low pitch. The role of speaking in too low pitch as causal for vocal symptoms and need for voice classification differentiation in vocal performance studies are discussed.
Noise in any frequency range can enhance information transmission in a sensory neuron
NASA Astrophysics Data System (ADS)
Levin, Jacob E.
1997-05-01
The effect of noise on the neural encoding of broadband signals was investigated in the cricket cercal system, a mechanosensory system sensitive to small near-field air particle disturbances. Known air current stimuli were presented to the cricket through audio speakers in a controlled environment in a variety of background noise conditions. Spike trains from the second layer of neuronal processing, the primary sensory interneurons, were recorded with intracellular Electrodes and the performance of these neurons characterized with the tools of information theory. SNR, mutual information rates, and other measures of encoding accuracy were calculated for single frequency, narrowband, and broadband signals over the entire amplitude sensitivity range of the cells, in the presence of uncorrelated noise background also spanning the cells' frequency and amplitude sensitivity range. Significant enhancements of transmitted information through the addition of external noise were observed regardless of the frequency range of either the signal or noise waveforms, provided both were within the operating range of the cell. Considerable improvements in signal encoding were observed for almost an entire order of magnitude of near-threshold signal amplitudes. This included sinusoidal signals embedded in broadband white noise, broadband signals in broadband noise, and even broadband signals presented with narrowband noise in a completely non-overlapping frequency range. The noise related increases in mutual information rate for broadband signals were as high as 150%, and up to 600% increases in SNR were observed for sinusoidal signals. Additionally, it was shown that the amount of information about the signal carried, on average, by each spike was INCREASED for small signals when presented with noise—implying that added input noise can, in certain situations, actually improve the accuracy of the encoding process itself.
Vocal impact of a prolonged reading task in dysphonic versus normophonic female teachers.
Remacle, Angélique; Morsomme, Dominique; Berrué, Elise; Finck, Camille
2012-11-01
This study evaluates the effect of a 2-hour reading task between 70 and 75 dB(A) in 16 normophonic and 16 dysphonic female teachers with vocal nodules. Objective measurements (acoustic analysis, voice range measurements, and aerodynamic measurements) and subjective self-ratings were collected before and every 30 minutes during the reading to determine the voice evolution in both groups. Fundamental frequency, lowest frequency, highest frequency (F-High), highest intensity, and intensity range increase through the reading, whereas shimmer decreases. Maximum phonation time decreases after 30 minutes. Estimated subglottal pressure (ESP) and sound pressure level increase during the first hour. Afterward, ESP decreases. Self-ratings worsen through time. When comparing the normophonic and the dysphonic teachers, self-ratings reveal more complaints in the dysphonic group. Few differences in objective measurements are found between both groups: normophonic teachers show lower ESP, higher F-High, and greater frequency range. Frequency modifications from acoustic analysis and voice range measurements suggest an increased laryngeal tension during vocal load, while subjects perceive a worsening of voice. Aerodynamic parameters depict first a deterioration of voice efficiency and then an adaptation to the prolonged reading. The comparison between both groups shows a discrepancy between objective measurements and self-ratings, suggesting that both approaches are necessary to have a complete view of vocal load effects. Surprisingly, both groups behave similarly through vocal load, without more or quicker deterioration of voice in the dysphonic group. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Weiyu; Wang, Chunhui; Ding, Haitao; Shao, Jinyou; Ding, Yucheng
2016-05-01
In this work, we focus on frequency-dependence of pearl chain formations (PCF) of gold nanoparticles driven by AC dielectrophoresis (DEP), especially in a low field-frequency range, where induced double-layer charging effect at ideally polarizable surfaces on particle DEP behavior and surrounding liquid motion need not be negligible. As field frequency varies, grown features of DEP assembly structures ranging from low-frequency non-bridged gap to high-frequency single gold nanoparticle-made nanowires bridging the electrodes are demonstrated experimentally. Specifically, at 10 kHz, a kind of novel channel-like structure with parallel opposing banks is formed at the center of interelectrode gap. In stark contrast, at 1 MHz, thin PCF with diameter of 100 nm is created along the shortest distance of the isolation spacing. Moreover, a particular conductive path of nanoparticle chains is produced at 1 MHz in a DEP device embedded with multiple floating electrodes. A theoretical framework taking into account field-induced double-layer polarization at both the particle/electrolyte and electrode/electrolyte interface is developed to correlate these experimental observations with induced-charge electrokinetic (ICEK) phenomenon. And a RC circuit model is helpful in accounting for the formation of this particular non-bridged channel-like structure induced by a low-frequency AC voltage. As compared to thin PCF formed at high field frequency that effectively short circuits the electrode pair, though it is difficult for complete PCF bridging to occur at low frequency, the non-bridged conducting microstructure has potential to further miniaturize the size of electrode gap fabricated by standard micromachining process and may find useful application in biochemical sensing.
Narrow band quantitative and multivariate electroencephalogram analysis of peri-adolescent period
2012-01-01
Background The peri-adolescent period is a crucial developmental moment of transition from childhood to emergent adulthood. The present report analyses the differences in Power Spectrum (PS) of the Electroencephalogram (EEG) between late childhood (24 children between 8 and 13 years old) and young adulthood (24 young adults between 18 and 23 years old). Results The narrow band analysis of the Electroencephalogram was computed in the frequency range of 0–20 Hz. The analysis of mean and variance suggested that six frequency ranges presented a different rate of maturation at these ages, namely: low delta, delta-theta, low alpha, high alpha, low beta and high beta. For most of these bands the maturation seems to occur later in anterior sites than posterior sites. Correlational analysis showed a lower pattern of correlation between different frequencies in children than in young adults, suggesting a certain asynchrony in the maturation of different rhythms. The topographical analysis revealed similar topographies of the different rhythms in children and young adults. Principal Component Analysis (PCA) demonstrated the same internal structure for the Electroencephalogram of both age groups. Principal Component Analysis allowed to separate four subcomponents in the alpha range. All these subcomponents peaked at a lower frequency in children than in young adults. Conclusions The present approaches complement and solve some of the incertitudes when the classical brain broad rhythm analysis is applied. Children have a higher absolute power than young adults for frequency ranges between 0-20 Hz, the correlation of Power Spectrum (PS) with age and the variance age comparison showed that there are six ranges of frequencies that can distinguish the level of EEG maturation in children and adults. The establishment of maturational order of different frequencies and its possible maturational interdependence would require a complete series including all the different ages. PMID:22920159
Apparatus for monitoring X-ray beam alignment
Steinmeyer, Peter A.
1991-10-08
A self-contained, hand-held apparatus is provided for minitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency.
Apparatus for monitoring X-ray beam alignment
Steinmeyer, P.A.
1991-10-08
A self-contained, hand-held apparatus is provided for monitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency. 2 figures.
Brand, Pierre; Boulanger, Benoît; Segonds, Patricia; Petit, Yannick; Félix, Corinne; Ménaert, Bertrand; Taira, Takunori; Ishizuki, Hideki
2009-09-01
We validated the theory of angular quasi-phase-matching (AQPM) by performing measurements of second-harmonic generation and difference-frequency generation. A nonlinear least-squares fitting of these experimental data led to refine the Sellmeier equations of 5%MgO:PPLN that are now valid over the complete transparency range of the crystal. We also showed that AQPM exhibits complementary spectral ranges and acceptances compared with birefringence phase matching.
Mitochondrial DNA (mtDNA) haplogroups in 1526 unrelated individuals from 11 Departments of Colombia
Yunis, Juan J.; Yunis, Emilio J.
2013-01-01
The frequencies of four mitochondrial Native American DNA haplogroups were determined in 1526 unrelated individuals from 11 Departments of Colombia and compared to the frequencies previously obtained for Amerindian and Afro-Colombian populations. Amerindian mtDNA haplogroups ranged from 74% to 97%. The lowest frequencies were found in Departments on the Caribbean coast and in the Pacific region, where the frequency of Afro-Colombians is higher, while the highest mtDNA Amerindian haplogroup frequencies were found in Departments that historically have a strong Amerindian heritage. Interestingly, all four mtDNA haplogroups were found in all Departments, in contrast to the complete absence of haplogroup D and high frequencies of haplogroup A in Amerindian populations in the Caribbean region of Colombia. Our results indicate that all four Native American mtDNA haplogroups were widely distributed in Colombia at the time of the Spanish conquest. PMID:24130438
Measurement and Simulation of Low Frequency Impulse Noise and Ground Vibration from Airblasts
NASA Astrophysics Data System (ADS)
Hole, L. R.; Kaynia, A. M.; Madshus, C.
1998-07-01
This paper presents numerical simulations of low frequency ground vibration and dynamic overpressure in air using two different numerical models. Analysis is based on actual recordings during blast tests at Haslemoen test site in Norway in June 1994. It is attempted to use the collected airblast-induced overpressures and ground vibrations in order to asses the applicability of the two models. The first model is a computer code which is based on a global representation of ground and atmospheric layers, a so-called Fast Field Program (FFP). A viscoelastic and a poroelastic version of this model is used. The second model is a two-dimensionalmoving-loadformulation for the propagation of airblast over ground. The poroelastic FFP gives the most complete and realistic reproduction of the processes involved, including decay of peak overpressure amplitude and dominant frequency of signals with range. It turns out that themoving-loadformulation does not provide a complete description of the physics involved when the speed of sound in air is different from the ground wavespeeds.
THz local oscillator sources: performance and capabilities
NASA Technical Reports Server (NTRS)
Mehdi, I.; Chattopadhyah, G.; Schlecht, E.; Siegel, P.
2002-01-01
Frequency multiplier circuits based on planar GaAs Schottky diodes have made significant advances in the last decade. Useful power in the >1 THz range has now been demonstrated from a complete solid-state chain. This paper will review some of the technology responsible for this achievement along with presenting a brief look at future challenges.
Noise in solid-state nanopores
Smeets, R. M. M.; Keyser, U. F.; Dekker, N. H.; Dekker, C.
2008-01-01
We study ionic current fluctuations in solid-state nanopores over a wide frequency range and present a complete description of the noise characteristics. At low frequencies (f ≲ 100 Hz) we observe 1/f-type of noise. We analyze this low-frequency noise at different salt concentrations and find that the noise power remarkably scales linearly with the inverse number of charge carriers, in agreement with Hooge's relation. We find a Hooge parameter α = (1.1 ± 0.1) × 10−4. In the high-frequency regime (f ≳ 1 kHz), we can model the increase in current power spectral density with frequency through a calculation of the Johnson noise. Finally, we use these results to compute the signal-to-noise ratio for DNA translocation for different salt concentrations and nanopore diameters, yielding the parameters for optimal detection efficiency. PMID:18184817
Noise in solid-state nanopores.
Smeets, R M M; Keyser, U F; Dekker, N H; Dekker, C
2008-01-15
We study ionic current fluctuations in solid-state nanopores over a wide frequency range and present a complete description of the noise characteristics. At low frequencies (f approximately < 100 Hz) we observe 1/f-type of noise. We analyze this low-frequency noise at different salt concentrations and find that the noise power remarkably scales linearly with the inverse number of charge carriers, in agreement with Hooge's relation. We find a Hooge parameter alpha = (1.1 +/- 0.1) x 10(-4). In the high-frequency regime (f approximately > 1 kHz), we can model the increase in current power spectral density with frequency through a calculation of the Johnson noise. Finally, we use these results to compute the signal-to-noise ratio for DNA translocation for different salt concentrations and nanopore diameters, yielding the parameters for optimal detection efficiency.
Yin, Qiwei; Lu, Huadong; Su, Jing; Peng, Kunchi
2016-05-01
The thermal lens effect of terbium gallium garnet (TGG) crystal in a high power single-frequency laser severely limits the output power and the beam quality of the laser. By inserting a potassium dideuterium phosphate (DKDP) slice with negative thermo-optical coefficient into the laser resonator, the harmful influence of the thermal lens effect of the TGG crystal can be effectively mitigated. Using this method, the stable range of the laser is broadened, the bistability phenomenon of the laser during the process of changing the pump power is completely eliminated, the highest output power of an all-solid-state continuous-wave intracavity-frequency-doubling single-frequency laser at 532 nm is enhanced to 30.2 W, and the beam quality of the laser is significantly improved.
Zhu, Ping; Jafari, Rana; Jones, Travis; Trebino, Rick
2017-10-02
We introduce a simple delay-scanned complete spatiotemporal intensity-and-phase measurement technique based on wavelength-multiplexed holography to characterize long, complex pulses in space and time. We demonstrate it using pulses emerging from multi-mode fiber. This technique extends the temporal range and spectral resolution of the single-frame STRIPED FISH technique without using an otherwise-required expensive ultranarrow-bandpass filter. With this technique, we measured the complete intensity and phase of up to ten fiber modes from a multi-mode fiber (normalized frequency V ≈10) over a ~3ps time range. Spatiotemporal complexities such as intermodal delay, modal dispersion, and material dispersion were also intuitively displayed by the retrieved results. Agreement between the reconstructed color movies and the monitored time-averaged spatial profiles confirms the validity to this delay-scanned STRIPED FISH method.
Autonomous and driven dynamics of spin torque nano-oscillators
NASA Astrophysics Data System (ADS)
Urazhdin, Sergei
2012-02-01
Understanding the dynamical properties of autonomous spin torque nano-oscillators (STNO) and their response to external perturbations is important for their applications as nanoscale microwave sources. We used spectroscopic measurements to study the dynamical characteristics of nanopillar- and point contact-based STNOs incorporating a microstrip in close proximity to the active magnetic layer. By applying microwave current at frequency fext to the microstrip, we were able to generate large microwave fields of more than 30 Oe rms at the location of STNO. We demonstrate that for a wide range of fext, STNO exhibits multiple synchronization regimes with integer and non-integer rational ratios between fext and the oscillation frequency f. We show that the synchronization ranges are determined by the symmetry of the oscillation orbit and the orientation of the driving field relative to the symmetry axis of the orbit. We observe synchronization hysteresis, i.e. a dependence of the synchronization limits on the dynamical history caused by the nonlinearity of STNO. We also show that the oscillation can be parametrically excited in the subcritical regime of STNO by a microwave field at twice the frequency of the oscillation. By measuring the threshold and the frequency range of parametric excitation, we determine damping, spin-polarization efficiency, and coupling to the microwave signal. In addition, by measuring the frequency range of parametric synchronization in the auto-oscillation regime, we determine the dynamic nonlinearity of the nanomagnet. Thus, analysis of the driven oscillations provides complete information about the dynamical characteristics of STNO. Finally, we discuss several unusual dynamical behaviors of STNO caused by their strong nonlinearity.
[The extraction and analysis of a- and b- wave from electroretinogram in human].
Chen, Zi-he; Zheng, Chang-wei; Lei, Bo
2013-12-01
To determine the frequency range of a-b wave complex in the dark- and light-adapted electroretinogram (ERG) and to isolate the pure a- and b- waves. Case series study. Full-field ERGs were recorded in 16 eyes of 8 normal volunteers from October to November 2011. Digital filtering technique was used to extract the a- and b-waves from dark- and light-adapted ERG responses. The timings of a- and b-wave were measured to determine the frequency range of a-b wave complex. Major frequency components were determined from power spectra using fast Fourier transform (FFT). The effect of different order settings in the digital filter were compared to investigate the optimum condition, where the oscillatory potential (OP) was completely removed while the amplitudes and phases of the a- and b- waves were less affected. The Student-t test was used to compare the frequency range of a-b wave complex in dark- and light-adapted ERG. The averaged frequency range of the dark-adapted a-b wave complex was from (14.99 ± 2.39) to (25.35 ± 3.77) Hz, compared with (25.22 ± 6.56) to (32.47 ± 3.68) Hz for the light-adapted a-b wave complex, respectively, indicating the frequency range of the dark-adapted a-b wave complex was significantly less than the light-adapted a-b wave complex (t = 7.910, 7.693; both P < 0.01). The third order of the digital filter and a passband of 1 to 45 Hz was the best choice in term of removing the high frequency OP from the waveform of ERG and keeping the amplitude and phase of the a- and b- waves. The frequency of a-b wave complex is lower than that of OP. Therefore the a- and b- waves can be isolated from OP using different digital filter settings in human ERG. A third order and a passband of 1 to 45 Hz is the best choice to extract pure a- and b- waves from the original ERG.
Otoacoustic emission responses of the cochlea to acute and total ischemia.
Yıldırım, Yavuz Selim; Aksoy, Fadlullah; Ozturan, Orhan; Veyseller, Bayram; Demirhan, Hasan
2013-12-01
In the present experimental study, we sought to monitor distortion product otoacoustic emissions (DPOAEs) as an indicator of cochlear function, after sudden, total, and irreversible interruption of cochlear blood flow, to provide information on the time course of cochlear response to ischemia. Twenty rats with normal hearing function were included. Complete and abrupt ischemia was provided by decapitation. DPOAEs at 3-8 kHz frequencies were recorded at baseline and exactly every consecutive minute after decapitation, until emissions in all frequencies disappeared completely. Mean DPOAE values decreased significantly and progressively after decapitation for all frequencies. The mean duration of emissions was 8.20 ± 1.96 min (minimum 3 min, maximum 11 min). The longest durations of DPOAEs were observed with 4 and 5 kHz frequencies, and 3 and 6 kHz had the shortest durations. The outer hair cells exposed to acute ischemia seem to exhibit a rapid functional loss; thus, cautious handling of the cochlear vasculature and surrounding structures is necessary in surgical interventions. Additionally, our results provide some idea of the normal tolerance range of the cochlea to ischemia, which could be useful for future studies.
Ultrasonic attenuation measurements determine onset, degree, and completion of recrystallization
NASA Technical Reports Server (NTRS)
Generazio, E. R.
1988-01-01
Ultrasonic attenuation was measured for cold worked Nickel 200 samples annealed at increasing temperatures. Localized dislocation density variations, crystalline order and volume percent of recrystallized phase were determined over the anneal temperature range using transmission electron microscopy, X-ray diffraction, and metallurgy. The exponent of the frequency dependence of the attenuation was found to be a key variable relating ultrasonic attenuation to the thermal kinetics of the recrystallization process. Identification of this key variable allows for the ultrasonic determination of onset, degree, and completion of recrystallization.
Real-Time Stability Margin Measurements for X-38 Robustness Analysis
NASA Technical Reports Server (NTRS)
Bosworth, John T.; Stachowiak, Susan J.
2005-01-01
A method has been developed for real-time stability margin measurement calculations. The method relies on a tailored-forced excitation targeted to a specific frequency range. Computation of the frequency response is matched to the specific frequencies contained in the excitation. A recursive Fourier transformation is used to make the method compatible with real-time calculation. The method was incorporated into the X-38 nonlinear simulation and applied to an X-38 robustness test. X-38 stability margins were calculated for different variations in aerodynamic and mass properties over the vehicle flight trajectory. The new method showed results comparable to more traditional stability analysis techniques, and at the same time, this new method provided coverage that is more complete and increased efficiency.
Orientation Tuning in the Visual Cortex of 3-Month-old Human Infants
Baker, Thomas J.; Norcia, Anthony M.; Candy, T. Rowan
2016-01-01
Sensitivity to orientation is critical for making a whole and complete picture of the world. We measured the orientation tuning of mechanisms inthe visual cortex of typically developing 3-month-olds and adults using a nonlinear analysis of the two-input steady-state visually evoked potential (VEP). Two gratings, one a fixed test and the other a variable orientation masker were tagged with distinct temporal frequencies and the corresponding evoked responses were measured at the harmonics of the test and masker frequencies and at a frequency equal to the sum of the two stimulus frequencies. The magnitude of the sum frequency component depended strongly on the relative orientation of the test and masker in both infants and adults. The VEP tuning bandwidths of the 3-month-olds measured at the sum frequency were similar to those of adults, suggesting that behavioral immaturities in functions such as orientation discrimination and contour integration may result from other immaturities in long-range lateral projections or feedback mechanisms. PMID:21236289
3D parallel-detection microwave tomography for clinical breast imaging
Meaney, P. M.; Paulsen, K. D.
2014-01-01
A biomedical microwave tomography system with 3D-imaging capabilities has been constructed and translated to the clinic. Updates to the hardware and reconfiguration of the electronic-network layouts in a more compartmentalized construct have streamlined system packaging. Upgrades to the data acquisition and microwave components have increased data-acquisition speeds and improved system performance. By incorporating analog-to-digital boards that accommodate the linear amplification and dynamic-range coverage our system requires, a complete set of data (for a fixed array position at a single frequency) is now acquired in 5.8 s. Replacement of key components (e.g., switches and power dividers) by devices with improved operational bandwidths has enhanced system response over a wider frequency range. High-integrity, low-power signals are routinely measured down to −130 dBm for frequencies ranging from 500 to 2300 MHz. Adequate inter-channel isolation has been maintained, and a dynamic range >110 dB has been achieved for the full operating frequency range (500–2900 MHz). For our primary band of interest, the associated measurement deviations are less than 0.33% and 0.5° for signal amplitude and phase values, respectively. A modified monopole antenna array (composed of two interwoven eight-element sub-arrays), in conjunction with an updated motion-control system capable of independently moving the sub-arrays to various in-plane and cross-plane positions within the illumination chamber, has been configured in the new design for full volumetric data acquisition. Signal-to-noise ratios (SNRs) are more than adequate for all transmit/receive antenna pairs over the full frequency range and for the variety of in-plane and cross-plane configurations. For proximal receivers, in-plane SNRs greater than 80 dB are observed up to 2900 MHz, while cross-plane SNRs greater than 80 dB are seen for 6 cm sub-array spacing (for frequencies up to 1500 MHz). We demonstrate accurate recovery of 3D dielectric property distributions for breast-like phantoms with tumor inclusions utilizing both the in-plane and new cross-plane data. PMID:25554311
Reinforcement of drinking by running: effect of fixed ratio and reinforcement time1
Premack, David; Schaeffer, Robert W.; Hundt, Alan
1964-01-01
Rats were required to complete varying numbers of licks (FR), ranging from 10 to 300, in order to free an activity wheel for predetermined times (CT) ranging from 2 to 20 sec. The reinforcement of drinking by running was shown both by an increased frequency of licking, and by changes in length of the burst of licking relative to operant-level burst length. In log-log coordinates, instrumental licking tended to be a linear increasing function of FR for the range tested, a linear decreasing function of CT for the range tested. Pause time was implicated in both of the above relations, being a generally increasing function of both FR and CT. PMID:14120150
REINFORCEMENT OF DRINKING BY RUNNING: EFFECT OF FIXED RATIO AND REINFORCEMENT TIME.
PREMACK, D; SCHAEFFER, R W; HUNDT, A
1964-01-01
Rats were required to complete varying numbers of licks (FR), ranging from 10 to 300, in order to free an activity wheel for predetermined times (CT) ranging from 2 to 20 sec. The reinforcement of drinking by running was shown both by an increased frequency of licking, and by changes in length of the burst of licking relative to operant-level burst length. In log-log coordinates, instrumental licking tended to be a linear increasing function of FR for the range tested, a linear decreasing function of CT for the range tested. Pause time was implicated in both of the above relations, being a generally increasing function of both FR and CT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batchelor, D.B.
This paper represents an attempt to express in print the contents of a rather philosophical review talk. The charge for the talk was not to summarize the present status of the field and what we can do, but to assess what we will need to do in the future and where the gaps are in fulfilling these needs. The objective was to be complete, covering all aspects of theory and modeling in all frequency regimes, although in the end the talk mainly focussed on the ion cyclotron range of frequencies (ICRF). In choosing which areas to develop, it is importantmore » to keep in mind who the customers for RF modeling are likely to be and what sorts of tasks they will need for RF to do. This occupies the first part of the paper. Then we examine each of the elements of a complete RF theory and try to identify the kinds of advances needed.« less
Digitally programmable signal generator and method
Priatko, G.J.; Kaskey, J.A.
1989-11-14
Disclosed is a digitally programmable waveform generator for generating completely arbitrary digital or analog waveforms from very low frequencies to frequencies in the gigasample per second range. A memory array with multiple parallel outputs is addressed; then the parallel output data is latched into buffer storage from which it is serially multiplexed out at a data rate many times faster than the access time of the memory array itself. While data is being multiplexed out serially, the memory array is accessed with the next required address and presents its data to the buffer storage before the serial multiplexing of the last group of data is completed, allowing this new data to then be latched into the buffer storage for smooth continuous serial data output. In a preferred implementation, a plurality of these serial data outputs are paralleled to form the input to a digital to analog converter, providing a programmable analog output. 6 figs.
Digitally programmable signal generator and method
Priatko, Gordon J.; Kaskey, Jeffrey A.
1989-01-01
A digitally programmable waveform generator for generating completely arbitrary digital or analog waveforms from very low frequencies to frequencies in the gigasample per second range. A memory array with multiple parallel outputs is addressed; then the parallel output data is latched into buffer storage from which it is serially multiplexed out at a data rate many times faster than the access time of the memory array itself. While data is being multiplexed out serially, the memory array is accessed with the next required address and presents its data to the buffer storage before the serial multiplexing of the last group of data is completed, allowing this new data to then be latched into the buffer storage for smooth continuous serial data output. In a preferred implementation, a plurality of these serial data outputs are paralleled to form the input to a digital to analog converter, providing a programmable analog output.
Subramania, Ganapathi; Lee, Yun-Ju; Brener, Igal; Luk, Ting-Shan; Clem, Paul G
2007-10-01
Photonic crystals (PC) have emerged as important types of structures for light manipulation. Ultimate control of light is possible by creating PCs with a complete three dimensional (3D) gap [1, 2]. This has proven to be a considerable challenge in the visible and ultraviolet frequencies mainly due to complications in integrating transparent, high refractive index (n) materials with fabrication techniques to create ~ 100nm features with long range translational order. In this letter, we demonstrate a nano-lithography approach based on a multilevel electron beam direct write and physical vapor deposition, to fabricate four-layer titania woodpile PCs that potentially exhibit complete 3D gap at visible wavelengths. We achieved a short wavelength bandedge of 525nm with a 300nm lattice constant PC. Due to the nanoscale precision and capability for defect control, the nanolithography approach represents an important step toward novel visible photonic devices for lighting, lasers, sensing and biophotonics.
Chirp-Z analysis for sol-gel transition monitoring.
Martinez, Loïc; Caplain, Emmanuel; Serfaty, Stéphane; Griesmar, Pascal; Gouedard, Gérard; Gindre, Marcel
2004-04-01
Gelation is a complex reaction that transforms a liquid medium into a solid one: the gel. In gel state, some gel materials (DMAP) have the singular property to ring in an audible frequency range when a pulse is applied. Before the gelation point, there is no transmission of slow waves observed; after the gelation point, the speed of sound in the gel rapidly increases from 0.1 to 10 m/s. The time evolution of the speed of sound can be measured, in frequency domain, by following the frequency spacing of the resonance peaks from the Synchronous Detection (SD) measurement method. Unfortunately, due to a constant frequency sampling rate, the relative error for low speeds (0.1 m/s) is 100%. In order to maintain a low constant relative error, in the whole speed time evolution range, Chirp-Z Transform (CZT) is used. This operation transforms a time variant signal to a time invariant one using only a time dependant stretching factor (S). In the frequency domain, the CZT enables us to stretch each collected spectrum from time signals. The blind identification of the S factor gives us the complete time evolution law of the speed of sound. Moreover, this method proves that the frequency bandwidth follows the same time law. These results point out that the minimum wavelength stays constant and that it only depends on the gel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iijima, Hokuto; Nagai, Ryoji; Nishimori, Nobuyuki
2009-12-15
A second-harmonic generation frequency-resolved optical gating (SHG-FROG) system has been developed for the complete characterization of laser pulses in the wavelength range of 10-30 {mu}m. A tellurium crystal is used so that spectrally resolved autocorrelation signals with a good signal-to-noise ratio are obtained. Pulses (wavelength {approx}22 {mu}m) generated from a free-electron laser are measured by the SHG-FROG system. The SHG intensity profile and the spectrum obtained by FROG measurements are well consistent with those of independent measurements of the pulse length and spectrum. The pulse duration and spectral width determined from the FROG trace are 0.6 ps and 5.2 THzmore » at full width half maximum, respectively.« less
An instrumental electrode model for solving EIT forward problems.
Zhang, Weida; Li, David
2014-10-01
An instrumental electrode model (IEM) capable of describing the performance of electrical impedance tomography (EIT) systems in the MHz frequency range has been proposed. Compared with the commonly used Complete Electrode Model (CEM), which assumes ideal front-end interfaces, the proposed model considers the effects of non-ideal components in the front-end circuits. This introduces an extra boundary condition in the forward model and offers a more accurate modelling for EIT systems. We have demonstrated its performance using simple geometry structures and compared the results with the CEM and full Maxwell methods. The IEM can provide a significantly more accurate approximation than the CEM in the MHz frequency range, where the full Maxwell methods are favoured over the quasi-static approximation. The improved electrode model will facilitate the future characterization and front-end design of real-world EIT systems.
NASA Astrophysics Data System (ADS)
Alizadeh Sahraei, Abolfazl; Ayati, Moosa; Baniassadi, Majid; Rodrigue, Denis; Baghani, Mostafa; Abdi, Yaser
2018-03-01
This study attempts to comprehensively investigate the effects of multi-walled carbon nanotubes (MWCNTs) on the AC and DC electrical conductivity of epoxy nanocomposites. The samples (0.2, 0.3, and 0.5 wt. % MWCNT) were produced using a combination of ultrason and shear mixing methods. DC measurements were performed by continuous measurement of the current-voltage response and the results were analyzed via a numerical percolation approach, while for the AC behavior, the frequency response was studied by analyzing phase difference and impedance in the 10 Hz to 0.2 MHz frequency range. The results showed that the dielectric parameters, including relative permittivity, impedance phase, and magnitude, present completely different behaviors for the frequency range and MWCNT weight fractions studied. To better understand the nanocomposites electrical behavior, equivalent electric circuits were also built for both DC and AC modes. The DC equivalent networks were developed based on the current-voltage curves, while the AC equivalent circuits were proposed by using an optimization problem according to the impedance magnitude and phase at different frequencies. The obtained equivalent electrical circuits were found to be highly useful tools to understand the physical mechanisms involved in MWCNT filled polymer nanocomposites.
Galvez, David A.; Zhang, Bin; Najar, Ahmed
2014-01-01
Plant ecologists have debated the mechanisms used by plants to cope with the impact of herbivore damage. While plant resistance mechanisms have received much attention, plant compensatory growth as a type of plant tolerance mechanisms has been less studied. We conducted a greenhouse experiment to evaluate compensatory growth for trembling aspen (Populus tremuloides) seedlings under varying intensities and frequencies of simulated defoliation, with or without nutrient enriched media. For the purpose of this study, changes in biomass production and non-structural carbohydrate concentrations (NSC) of roots and leaves were considered compensatory responses. All defoliated seedlings showed biomass accumulation under low defoliation intensity and frequency, regardless of resource availability; however, as defoliation intensity and frequency increased, compensatory growth of seedlings was altered depending on resource availability. Seedlings in a resource-rich environment showed complete compensation, in contrast responses ranged from undercompensation to complete compensation in a resource-limited environment. Furthermore, at the highest defoliation intensity and frequency, NSC concentrations in leaves and roots were similar between defoliated and non-defoliated seedlings in a resource-rich environment; in contrast, defoliated seedlings with limited resources sustained the most biomass loss, had lower amounts of stored NSC. Using these results, we developed a new predictive framework incorporating the interactions between frequency and intensity of defoliation and resource availability as modulators of plant compensatory responses. PMID:25083352
Unusual phonon behavior and ultra-low thermal conductance of monolayer InSe.
Zhou, Hangbo; Cai, Yongqing; Zhang, Gang; Zhang, Yong-Wei
2017-12-21
Monolayer indium selenide (InSe) possesses numerous fascinating properties, such as high electron mobility, quantum Hall effect and anomalous optical response. However, its phonon properties, thermal transport properties and the origin of its structural stability remain unexplored. Using first-principles calculations, we show that the atoms in InSe are highly polarized and such polarization causes strong long-range dipole-dipole interaction (DDI). For acoustic modes, DDI is essential for maintaining its structural stability. For optical modes, DDI causes a significant frequency shift of its out-of-phase vibrations. Surprisingly, we observed that there were two isolated frequency regimes, which were completely separated from other frequency regimes with large frequency gaps. Within each frequency regime, only a single phonon mode exists. We further reveal that InSe possesses the lowest thermal conductance among the known two-dimensional materials due to the low cut-off frequency, low phonon group velocities and the presence of large frequency gaps. These unique behaviors of monolayer InSe can enable the fabrication of novel devices, such as thermoelectric module, single-mode phonon channel and phononic laser.
Dailey, Deena D; Braun, Christopher B
2011-08-01
Goldfish (Carassius auratus) were conditioned to suppress respiration to a 40-Hz vibratory source and subsequently tested for stimulus generalization to frequency, stimulus amplitude, and position (azimuth). Animals completely failed to generalize to frequencies separated by octave intervals both lesser and greater than the CS. However, they did appear to generalize weakly to an aerial loudspeaker stimulus of the same frequency (40 Hz) after conditioning with an underwater vibratory source. Animals had a gradually decreasing amount of generalization to amplitude changes, suggesting a perceptual dimension of loudness. Animals generalized largely or completely to the same underwater source presented at a range of source azimuths. When these azimuths were presented at a transect of 3 cm, some animals did show decrements in generalization, while others did not. This suggests that although azimuth may be perceived more saliently at distances closer to a dipole source, perception of position is not immediately salient in conditioned vibratory source detection. Differential responding to test stimuli located toward the head or tail suggests the presence of perceptual differences between sources that are rostral or caudal with respect to the position of the animal or perhaps the head. PsycINFO Database Record (c) 2011 APA, all rights reserved.
Andersen, L Frost; Tomten, H; Haggarty, P; Løvø, A; Hustvedt, B-E
2003-02-01
The validation of dietary assessment methods is critical in the evaluation of the relation between dietary intake and health. The aim of this study was to assess the validity of a food frequency questionnaire by comparing energy intake with energy expenditure measured with the doubly labelled water method. Total energy expenditure was measured with the doubly labelled water (DLW) method during a 10 day period. Furthermore, the subjects filled in the food frequency questionnaire about 18-35 days after the DLW phase of the study was completed. Twenty-one healthy, non-pregnant females volunteered to participate in the study; only 17 subjects completed the study. The group energy intake was on average 10% lower than the energy expenditure, but the difference was not statistically significant. However, there was a wide range in reporting accuracy: seven subjects were identified as acceptable reporters, eight as under-reporters and two were identified as over-reporters. The width of the 95% confidence limits of agreement in a Bland and Altman plot for energy intake and energy expenditure varied from -5 to 3 MJ. The data showed that there was substantial variability in the accuracy of the food frequency questionnaire at the individual level. Furthermore, the results showed that the questionnaire was more accurate for groups than individuals.
Gonçalves, Marcele Giacomin; Heineck, Isabela
2016-01-01
To determine the frequency of prescriptions of off-label drugs and drugs not approved for pediatric use in primary health care in medium-sized municipality of Rio Grande do Sul, Brazil. Cross-sectional study with retrospective data collection, which analyzed prescriptions issued to 326 patients from August to December/2012 in two basic health units in the city of Viamão, state of Rio Grande do Sul. It included all prescriptions of patients whose medical records or service records were available and complete in relation to the date of presence, weight and date of birth. Off-label prescriptions were those which, in relation to the drug leaflet, showed dose different the recommended range, frequency of prescription and/or different form of administration and younger age than the indicated range. Descriptive statistics with absolute frequencies, means and standard deviations were used. During the study period, a total of 731 drug prescriptions were issued and the frequency of off-label medications prescribed was 31.7%, especially antihistamines and antiasthmatics (32.3% and 31.5%, respectively). The main type of off-label prescription was dose (38.8%), followed by age range (31.5%) and frequency of administration (29.3%). Regarding the dose off-label prescription, overdose was more frequent (93.3%) than the underdose (6.7%). Prescriptions of unapproved drugs were not identified. The study showed that off label prescription is common in both assessed units. The observed percentage of off label prescription was higher than that reported by European studies carried out in primary care. On the other hand, the prescription of drugs not approved for children was not observed. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.
Gonçalves, Marcele Giacomin; Heineck, Isabela
2016-01-01
Abstract Objective: To determine the frequency of prescriptions of off-label drugs and drugs not approved for pediatric use in primary health care in medium-sized municipality of Rio Grande do Sul, Brazil. Methods: Cross-sectional study with retrospective data collection, which analyzed prescriptions issued to 326 patients from August to December/2012 in two basic health units in the city of Viamão, state of Rio Grande do Sul. It included all prescriptions of patients whose medical records or service records were available and complete in relation to the date of presence, weight and date of birth. Off-label prescriptions were those which, in relation to the drug leaflet, showed dose different the recommended range, frequency of prescription and/or different form of administration and younger age than the indicated range. Descriptive statistics with absolute frequencies, means and standard deviations were used. Results: During the study period, a total of 731 drug prescriptions were issued and the frequency of off-label medications prescribed was 31.7%, especially antihistamines and antiasthmatics (32.3% and 31.5%, respectively). The main type of off-label prescription was dose (38.8%), followed by age range (31.5%) and frequency of administration (29.3%). Regarding the dose off-label prescription, overdose was more frequent (93.3%) than the underdose (6.7%). Prescriptions of unapproved drugs were not identified. Conclusions: The study showed that off label prescription is common in both assessed units. The observed percentage of off label prescription was higher than that reported by European studies carried out in primary care. On the other hand, the prescription of drugs not approved for children was not observed. PMID:26530249
Broadband Metamaterial for Nonresonant Matching of Acoustic Waves
2012-03-28
35898, USA. Unity transmittance at an interface between bulk media is quite common for polarized electromagnetic waves incident at the Brewster angle ...metamaterial possessing a Brewster -like angle that is completely transparent to sound waves over an ultra-broadband frequency range with .100% bandwidth...Unity transmittance at an interface between bulk media is quite common for polarized electromagnetic waves incident at the Brewster angle , but it is
Mid-Frequency Sonar Interactions with Beaked Whales
2011-06-30
Beaked Whale, was not completed. However, several other goals were achieved, including synthesis of a morphometric model of a beaked whale. This and work...induced acoustic fields inside beaked whales and other marine mammals. Another high-level goal was to acquire new high-resolution morphometric and...range 1-10 kHz; collecting high-resolution morphometric data through computerized tomography (CT) scans on marine mammal specimens, and constructing
Psycho-physiological training approach for amputee rehabilitation.
Dhal, Chandan; Wahi, Akshat
2015-01-01
Electromyography (EMG) signals are very noisy and difficult to acquire. Conventional techniques involve amplification and filtering through analog circuits, which makes the system very unstable. The surface EMG signals lie in the frequency range of 6Hz to 600Hz, and the dominant range is between the ranges from 20Hz to 150Hz. 1 Our project aimed to analyze an EMG signal effectively over its complete frequency range. To remove these defects, we designed what we think is an easy, effective, and reliable signal processing technique. We did spectrum analysis, so as to perform all the processing such as amplification, filtering, and thresholding on an Arduino Uno board, hence removing the need for analog amplifiers and filtering circuits, which have stability issues. The conversion of time domain to frequency domain of any signal gives a detailed data of the signal set. Our main aim is to use this useful data for an alternative methodology for rehabilitation called a psychophysiological approach to rehabilitation in prosthesis, which can reduce the cost of the myoelectric arm, as well as increase its efficiency. This method allows the user to gain control over their muscle sets in a less stressful environment. Further, we also have described how our approach is viable and can benefit the rehabilitation process. We used our DSP EMG signals to play an online game and showed how this approach can be used in rehabilitation.
Dittmar, M
1995-12-01
A review was made of all studies available from the literature referring to polymorphic blood systems of South American Aymara Indians. 33 original papers published up to 1990 covering a period of 45 years were summarized. Aymara samples were considered from a total of 55 localities in Bolivia, Peru, and Chile. Gene frequencies were tabulated for 21 polymorphic genetic systems comprising blood groups (AB0, MNSs, P, Rh, Lu, K, Le, Fy, Jk, Di), erythrocyte enzyme groups (AcP, 6PGD, PGM1, AK, ADA, EsD), and plasma protein groups (Hp, Tf, Gc, Gm, Km). Weighted average and range over all Aymara samples were computed for each blood system and compared with corresponding mean value and range in South Amerindians in general. Gene frequency distribution in the Aymara population shows ranges of different orders of magnitude in the 21 blood systems, some of them varying widely. Nevertheless the average gene frequencies for the Aymara are well within the range of values reported for South American Indian populations. The assessment of blood systems in the Aymara revealed that information concerning the Lutheran and HLA systems is scarce or nil up to now. Further studies are needed, especially from Peru on erythrocyte enzyme systems, in order to obtain a more complete picture on the variation of blood system polymorphisms in the Aymara population.
Design of large zoom for visible and infrared optical system in hemisphere space
NASA Astrophysics Data System (ADS)
Xing, Yang-guang; Li, Lin; Zhang, Juan
2018-01-01
In the field of space optical, the application of advanced optical instruments for related target detection and identification has become an advanced technology in modern optics. In order to complete the task of search in wide field of view and detailed investigation in small field of view, it is inevitable to use the structure of the zoom system to achieve a better observation for important targets. The innovation of this paper lies in using the zoom optical system in space detection, which achieve firstly military needs of searched target in the large field of view and recognized target in the small field of view. At the same time, this paper also completes firstly the design of variable focus optical detection system in the range of hemisphere space, the zoom optical system is working in the range of visible and infrared wavelengths, the perspective angle reaches 360 ° and the zoom ratio of the visible system is up to 15. The visible system has a zoom range of 60-900 mm, a detection band of 0.48-0.70μm, and a F-number of 2.0 to 5.0. The infrared system has a zoom range of 150 900mm, a detection band of 8-12μm, and a F-number of 1.2 to 3.0. The MTF of the visible zoom system is above 0.4 at spatial frequency of 45 lp / mm, and the infrared zoom system is above 0.4 at spatial frequency of 11 lp / mm. The design results show that the system has a good image quality.
Low-frequency vibration isolation in sandwich plates by piezoelectric shunting arrays
NASA Astrophysics Data System (ADS)
Chen, Shengbing; Wang, Gang; Song, Yubao
2016-12-01
Piezoelectric shunting arrays are proposed to isolate low-frequency vibrations transmitted in sandwich plates. The performance is characterized through application of finite element method. The numerical result shows that a complete band gap, whose width is about 20 Hz, is produced in the desired low-frequency ranges. The band gap is induced by local resonances of the shunting circuits, whose location is strongly related to the inductance, while the resistance can broaden the band gap to some extent. Vibration experiments are conducted on a 1200 × 1000 × 15 mm aluminum honeycomb plate with two arrays of 5 × 5 shunted piezoelectric patches bonded on the surface panels. Significant attenuation is found in the experimental results, which agree well with the theoretical predictions. Consequently, the proposed idea is feasible and effective.
CMOS micromachined capacitive cantilevers for mass sensing
NASA Astrophysics Data System (ADS)
Li, Ying-Chung; Ho, Meng-Han; Hung, Shi-Jie; Chen, Meng-Huei; S-C Lu, Michael
2006-12-01
In this paper, we present the design, fabrication and characterization of the CMOS micromachined cantilevers for mass sensing in the femtogram range. The cantilevers consisting of multiple metal and dielectric layers are fabricated after completion of a conventional CMOS process by dry etching steps. The cantilevers are electrostatically actuated to resonance by in-plane electrodes. The mechanical resonant frequency is detected capacitively with on-chip circuitry, where the modulation technique is applied to eliminate capacitive feedthrough from the driving port and to lessen the effect of flicker noise. The highest resonant frequency of the cantilevers is measured at 396.46 kHz with a quality factor of 2600 at 10 mTorr. The resonant frequency shift after deposition of a 0.1 µm SiO2 layer is 140 Hz, averaging 353 fg Hz-1.
Roberto, Anna; Radrezza, Silvia; Mosconi, Paola
2018-04-10
In recent years the question of the lack of transparency in clinical research has been debated by clinicians, researchers, citizens and their representatives, authors and publishers. This is particularly important for infrequent cancers such as ovarian cancer, where treatment still gives disappointing results in the majority of cases. Our aim was to assess the availability to the public of results in ClinicalTrials.gov, and the frequency of non-publication of results in ClinicalTrials.gov and in PubMed, Embase and Google Scholar. We collected all trials on ovarian cancer identified as "completed status" in the ClinicalTrials.gov registry on 17 January 2017. We checked the availability of the results in ClinicalTrials.gov and systematically identified published manuscripts on results. Out of 2725 trials on ovarian cancer identified, 752 were classified as "completed status". In those closed between 2008 and 2015, excluding phase I, the frequency of results in ClinicalTrials.gov was 35%. Of the 752 completed studies the frequency of published results in PubMed, Embase or Google Scholar ranged from 57.9% to 69.7% in the last years. These findings show a lack of transparency and credibility of research. Citizens or patients' representatives, with the medical community, should continuously support initiatives to improve the publication and dissemination of clinical study results.
Remote sounding of cloudy atmospheres. I - The single cloud layer
NASA Technical Reports Server (NTRS)
Chahine, M. T.
1974-01-01
The relaxation method for the inverse solution of the radiative transfer equation is applied in a dual-frequency scheme for the determination of complete vertical temperature profiles in cloudy atmospheres from radiance observations alone, without any additional information related to the expected solutions. The dual-frequency principle employs to advantage a property in the Planck function of the dependence of intensity on frequency. This property leads to the formulation of a new convergence criterion for the selection of cloud-sounding frequencies to be used for reconstructing the clear column radiance from observations made in the presence of a broken cloud layer in all fields of view. The principle is applied to the case of observations in two adjacent or partially overlapping fields of view and to the case of observations in a single field of view. The solutions are illustrated by numerical examples in the dual-frequency ranges of the 4.3 and 15-micron CO2 bands of the terrestrial atmosphere.
Nondestructive evaluation techniques for nickel-cadmium aerospace battery cells
NASA Technical Reports Server (NTRS)
Haak, R.; Tench, D.
1982-01-01
The ac impedance characteristics of Ni-Cd cells as an in-situ, nondestructive means of determining cell lifetime, particularly with respect to the probability of premature failure were evaluated. Emphasis was on evaluating Ni-Cd cell impedance over a wide frequency range (10,000 to 0.0004 Hz) as the cells were subjected to charge/discharge cycle testing. The results indicate that cell degradation is reflected in the low frequency (Warburg) impedance characteristics associated with diffusion processes. The Warburg slope (W) was found to steadily increase as a function of cell aging for completely discharged cells. In addition, based on data for two cells, a high or rapidly increasing value for W signals imminent cell failure by one mechanism. Degradation by another mechanism is apparently reflected in a fall-off (roll-over) of W at lower frequencies. As a secondary result, the frequency dependence of the absolute cell impedance at low frequencies (5 - 500 mHz) was found to be a good indication of the cell state-of-charge.
NASA Astrophysics Data System (ADS)
Dwyer, S.; LIGO Scientific Collaboration
2015-05-01
Advanced LIGO is currently in the final stages of installation and early commissioning. In the design of Advanced LIGO a key goal was the ability to detect gravitational waves from compact object binary inspirals, as these are thought to be the most likely candidates for early detections with ground based interferometers. Special emphasis has been placed on improving the low frequency sensitivity relative to the first generations of LIGO, in addition to improving the high frequency sensitivity by increasing the laser power. The interferometer in Livingston Louisiana has been locked (continuously held within the linear operating range) and noise investigations have begun, and the major installation activities for the interferometer at Hanford, Washington are completed.
The LOFAR Multifrequency Snapshot Sky Survey (MSSS): Status and Results
NASA Astrophysics Data System (ADS)
Heald, George; LOFAR Collaboration
2014-01-01
The Multifrequency Snapshot Sky Survey (MSSS) is the first large-area survey of the northern sky with the Low Frequency Array (LOFAR). By producing images of the sky at 16 frequencies from 30 to 160 MHz, MSSS probes the low-frequency sky at a sensitivity of order 10 mJy/beam, and angular resolution of 1-2 arcmin or better. It thus dramatically expands the frequency range sampled in high-resolution radio surveys, and, crucially, provides low-frequency spectral information about the detected sources. Using LOFAR's unique multi-beaming mode, the survey requires only a rather modest investment in observing time. MSSS began observations in late 2011, and has nearly completed observations in both frequency components (8 frequencies spanning the 30 to 74 MHz range, and another 8 spanning 120 to 160 MHz). MSSS has driven the initial development of the first production version of LOFAR's automatic Imaging Pipeline and spearheaded efforts aimed at solving some of the ongoing low-frequency calibration challenges. In this contribution, I will briefly review the survey design, including an overview of MSSS science topics. I will also present a status update, highlighting early results from the survey such as an in-depth look at the 100 square degree “MSSS Verification Field,” new sources discovered in MSSS images, and a sneak peek at the full survey area. I will conclude by describing plans for the future of MSSS, including the possibility of reprocessing the data to obtain enhanced data products such as higher resolution imaging and polarization. LOFAR, the Low Frequency Array designed and constructed by ASTRON, has facilities in several countries, that are owned by various parties (each with their own funding sources), and that are collectively operated by the International LOFAR Telescope (ILT) foundation under a joint scientific policy.
Magnetic sensor for building structural vibrations.
García, Alfonso; Morón, Carlos; Tremps, Enrique
2014-02-05
This paper shows a new displacement-to-frequency transducer based on the variation of a coil inductance when a magnetic core is partially or completely inserted inside. This transducer is based on a Colpitts oscillator due its low manufacturing price, behavior and immunity to noise. A tank circuit with a configuration in parallel was used because it can be employed at lower frequencies and it enables it to make a direct analysis. The sensor has a dynamic range equal to the length of the coil. The cores can exchange sensors (coils with its ferromagnetic core) using the same electronic measuring system. In this way, with only an electronic circuit, the core sensor determines the measurement range. The obtained resolution is higher than 1/100,000, and the sensor also allows the measurement and knowing in real time the effect of vibration, thermal expansion, referred overload movements, etc.., that can occur in the structural elements of a building.
Laser-driven high-frequency vibrations of metal blister surface
NASA Astrophysics Data System (ADS)
Kononenko, T. V.; Sinyavsky, M. N.; Konov, V. I.; Sentis, M.
2013-09-01
Time-resolved interferometric microscopy was applied to investigate laser-induced blistering of a titanium film on a silica substrate. Ablation of the titanium/silica interface by single 0.7 ns pulses within a certain fluence range results in local exfoliation of the metal film from the substrate avoiding, however, complete film destruction. Time-dependent transformation of the metal surface profile was reconstructed from the interference patterns within 0-13 ns time delay range. Transverse annular waves with typical amplitude of one hundred of nanometers and estimated traveling speed of few kilometers per second were revealed on the blister surface. The wave occurrence was attributed to fast inhomogeneous bending of the film covering the expanding blister. The resultant high-frequency (˜1 GHz) vibrations of the metal surface provide intensive inertial forces when such metalized target is used for blister-based laser-induced forward transfer of nanopowders and organic molecules.
Magnetic Sensor for Building Structural Vibrations
García, Alfonso; Morón, Carlos; Tremps, Enrique
2014-01-01
This paper shows a new displacement-to-frequency transducer based on the variation of a coil inductance when a magnetic core is partially or completely inserted inside. This transducer is based on a Colpitts oscillator due its low manufacturing price, behavior and immunity to noise. A tank circuit with a configuration in parallel was used because it can be employed at lower frequencies and it enables it to make a direct analysis. The sensor has a dynamic range equal to the length of the coil. The cores can exchange sensors (coils with its ferromagnetic core) using the same electronic measuring system. In this way, with only an electronic circuit, the core sensor determines the measurement range. The obtained resolution is higher than 1/100,000, and the sensor also allows the measurement and knowing in real time the effect of vibration, thermal expansion, referred overload movements, etc.., that can occur in the structural elements of a building. PMID:24504104
Comprehensive electrical analysis of metal/Al2O3/O-terminated diamond capacitance
NASA Astrophysics Data System (ADS)
Pham, T. T.; Maréchal, A.; Muret, P.; Eon, D.; Gheeraert, E.; Rouger, N.; Pernot, J.
2018-04-01
Metal oxide semiconductor capacitors were fabricated using p - type oxygen-terminated (001) diamond and Al2O3 deposited by atomic layer deposition at two different temperatures 250 °C and 380 °C. Current voltage I(V), capacitance voltage C(V), and capacitance frequency C(f) measurements were performed and analyzed for frequencies ranging from 1 Hz to 1 MHz and temperatures from 160 K to 360 K. A complete model for the Metal-Oxide-Semiconductor Capacitors electrostatics, leakage current mechanisms through the oxide into the semiconductor and small a.c. signal equivalent circuit of the device is proposed and discussed. Interface states densities are then evaluated in the range of 1012eV-1cm-2 . The strong Fermi level pinning is demonstrated to be induced by the combined effects of the leakage current through the oxide and the presence of diamond/oxide interface states.
Wide bandwidth phase-locked loop circuit
NASA Technical Reports Server (NTRS)
Koudelka, Robert David (Inventor)
2005-01-01
A PLL circuit uses a multiple frequency range PLL in order to phase lock input signals having a wide range of frequencies. The PLL includes a VCO capable of operating in multiple different frequency ranges and a divider bank independently configurable to divide the output of the VCO. A frequency detector detects a frequency of the input signal and a frequency selector selects an appropriate frequency range for the PLL. The frequency selector automatically switches the PLL to a different frequency range as needed in response to a change in the input signal frequency. Frequency range hysteresis is implemented to avoid operating the PLL near a frequency range boundary.
Kanick, Stephen Chad; McClatchy, David M; Krishnaswamy, Venkataramanan; Elliott, Jonathan T; Paulsen, Keith D; Pogue, Brian W
2014-10-01
This study investigates the hypothesis that structured light reflectance imaging with high spatial frequency patterns [Formula: see text] can be used to quantitatively map the anisotropic scattering phase function distribution [Formula: see text] in turbid media. Monte Carlo simulations were used in part to establish a semi-empirical model of demodulated reflectance ([Formula: see text]) in terms of dimensionless scattering [Formula: see text] and [Formula: see text], a metric of the first two moments of the [Formula: see text] distribution. Experiments completed in tissue-simulating phantoms showed that simultaneous analysis of [Formula: see text] spectra sampled at multiple [Formula: see text] in the frequency range [0.05-0.5] [Formula: see text] allowed accurate estimation of both [Formula: see text] in the relevant tissue range [0.4-1.8] [Formula: see text], and [Formula: see text] in the range [1.4-1.75]. Pilot measurements of a healthy volunteer exhibited [Formula: see text]-based contrast between scar tissue and surrounding normal skin, which was not as apparent in wide field diffuse imaging. These results represent the first wide-field maps to quantify sub-diffuse scattering parameters, which are sensitive to sub-microscopic tissue structures and composition, and therefore, offer potential for fast diagnostic imaging of ultrastructure on a size scale that is relevant to surgical applications.
Cuttler, Carrie; Spradlin, Alexander
2017-01-01
We created the Daily Sessions, Frequency, Age of Onset, and Quantity of Cannabis Use Inventory (DFAQ-CU) because the current lack of psychometrically sound inventories for measuring these dimensions of cannabis use has impeded research on the effects of cannabis in humans. A sample of 2,062 cannabis users completed the DFAQ-CU and was used to assess the DFAQ-CU's factor structure and reliability. To assess validity, a subsample of 645 participants completed additional measures of cannabis dependence and problems (Marijuana Smoking History Questionnaire [MSHQ], Timeline Followback [TLFB], Cannabis Abuse Screening Test [CAST], Cannabis Use Disorders Identification Test Revised [CUDIT-R], Cannabis Use Problems Identification Test [CUPIT], and Alcohol Use Disorder Identification Test [AUDIT]). A six-factor structure was revealed, with factors measuring: daily sessions, frequency, age of onset, marijuana quantity, cannabis concentrate quantity, and edibles quantity. The factors were reliable, with Cronbach's alpha coefficients ranging from .69 (daily sessions) to .95 (frequency). Results further provided evidence for the factors' convergent (MSHQ, TLFB), predictive (CAST, CUDIT-R, CUPIT), and discriminant validity (AUDIT). The DFAQ-CU is the first psychometrically sound inventory for measuring frequency, age of onset, and quantity of cannabis use. It contains pictures of marijuana to facilitate the measurement of quantity of marijuana used, as well as questions to assess the use of different forms of cannabis (e.g., concentrates, edibles), methods of administering cannabis (e.g., joints, hand pipes, vaporizers), and typical THC levels. As such, the DFAQ-CU should help facilitate research on frequency, quantity, and age of onset of cannabis use.
A Broadband VHF-L Band Cavity-Backed Slot Spiral Antenna
2005-05-01
each new frequency. When the frequency list is completed, the Flight Test Engineer will contact the Test Technician and request any necessary...immediately required elsewhere. Frequency List ; 50.05 MHz, 144.05 MHz, 432.05 MHz, 902.05 MHz, 1.29605 GHz...Repeat Completed? (Y/N) Test Completed? (Y/N) Frequency List ; 50.05 MHz, 144.05 MHz, 432.05 MHz, 902.05 MHz, 1.29605 GHz
Time and frequency comparisons in Europe by means of ECS 5 geostationary satellite
NASA Technical Reports Server (NTRS)
Cordara, Franco; Pettiti, V.; Cenci, A.; Fermi, M.; Sciarretta, C.
1990-01-01
A time synchronization experiment between some European laboratories using the passive television method applied to the signals broadcasted by Eutelsat I-F5 telecommunication satellite was completed in 1990. The results obtained in the last period, when also range measurements from a Telespazio ground station were performed, are analyzed to evaluate the accuracy level of the time comparisons corrected for the effect of the satellite movement with position data obtained either from the European Space Agency (ESA) or from orbit determination with range data entered into GEODYN program of NASA/GSFC.
Characterizing noise in the global nuclear weapon monitoring system
NASA Astrophysics Data System (ADS)
Schultz, Colin
2013-03-01
Under the auspices of the Comprehensive Nuclear-Test-Ban Treaty Organization, a worldwide monitoring system designed to detect the illegal testing of nuclear weaponry has been under construction since 1999. The International Monitoring System is composed of a range of sensors, including detectors for hydroacoustic and seismic signals, and when completed, will include 60 infrasound measurement arrays set to detect low-frequency sound waves produced by an atmospheric nuclear detonation.
2016-10-07
range due to either the geodesic correction or the element positioning. Figure 3. The travel time between N1 and S1 obtained from modeling with...chain running due north at 170°E. The effect of these bathymetric interactions is to fill the shadow zone completely by the time the Asian...the width of the envelope reduces with increasing frequency, enabling a higher time resolution. Furthermore, the lag time becomes smaller with
NASA Astrophysics Data System (ADS)
Ascher, A.; Lehner, M.; Eberhardt, M.; Biebl, E.
2015-11-01
The sensitivity of passive UHF RFID transponders (Radio Frequency Identification) is the key issue, which determines the maximum read range of an UHF RFID system. During this work the ability of improving the sensitivity using solar energy harvesting, especially for low light conditions, is shown. To use the additional energy harvested from the examined silicon and organic solar cells, the passive RFID system is changed into a semi-active one. This needs no changes on the reader hardware itself, only the used RFIC (Radio Frequency Integrated Circuit) of the transponder has to possess an additional input pin for an external supply voltage. The silicon and organic cells are evaluated and compared to each other regarding their low light performance. The different cells are examined in a shielded box, which is protected from the environmental lighting. Additionally, a demonstrator is shown, which makes the measurement of the extended read range with respect to the lighting conditions possible. If the cells are completely darkened, the sensitivity gain is ascertained using high capacity super caps. Due to the measurements an enhancement in range up to 70 % could be guaranteed even under low light conditions.
Aguiar Santos, Susana; Schlebusch, Thomas; Leonhardt, Steffen
2013-01-01
An accurate current source is one of the keys in the hardware of Electrical impedance Tomography systems. Limitations appear mainly at higher frequencies and for non-simple resistive loads. In this paper, we simulate an improved Howland current source with a Cole-Cole load. Simulations comparing two different op-amps (THS4021 and OPA843) were performed at 1 kHz to 1 MHz. Results show that the THS4021 performed better than the OPA843. The current source with THS4021 reaches an output impedance of 20 MΩ at 1 kHz and above 320 kΩ at 1 MHz, it provides a constant and stable output current up to 4 mA, in the complete range of frequencies, and for Cole-Cole (resistive and capacitive) load.
Lindwall, Magnus; Hassmén, Peter
2004-12-01
The purpose of this study was to investigate how scores on the Physical Self-Perception Profile (PSPP), including scores on the Perceived Importance Profile (PIP), were related to self-reported exercise frequency, duration, and gender in sample of Swedish university students. A total of 164 participants completed the PSPP, PIP, and a questionnaire focusing on frequency and duration of exercise. Exercise frequency, duration, and gender predicted best the PSPP sub-domains of Sport Competence and Physical Conditioning. Exercising more frequently, and for a longer time on each occasion was associated with higher PSPP and PIP scores. Women generally displayed lower PSPP scores than men. These results suggest that exercise professionals need to master a range of appropriate exercise strategies, since doubts concerning self-presentation may work against establishing a regular exercise routine.
Paolino, P; Bellon, L
2009-10-07
We measure the mechanical thermal noise of soft silicon atomic force microscope cantilevers. Using an interferometric setup, we obtain a resolution down to 10(-14) m Hz(-1/2) on a wide spectral range (3-10(5) Hz). The low frequency behavior depends dramatically on the presence of a reflective coating: almost flat spectra for uncoated cantilevers versus a 1/f like trend for coated ones. The addition of a viscoelastic term in models of the mechanical system can account for this observation. Use of Kramers-Kronig relations validate this approach with a complete determination of the response of the cantilever: a power law with a small coefficient is found for the frequency dependence of viscoelasticity due to the coating, whereas the viscous damping due to the surrounding atmosphere is accurately described by the Sader model.
Huang, Li; Chen, Hou -Tong; Zeng, Beibei; ...
2016-03-30
Metamaterials/metasurfaces have enabled unprecedented manipulation of electromagnetic waves. Here we present a new design of metasurface structure functioning as antireflection coatings. The structure consists of a subwavelength metallic mesh capped with a thin dielectric layer on top of a substrate. By tailoring the geometric parameters of the metallic mesh and the refractive index and thickness of the capping dielectric film, reflection from the substrate can be completely eliminated at a specific frequency. Compared to traditional methods such as coatings with single- or multi-layer dielectric films, the metasurface antireflection coatings are much thinner and the requirement of index matching is largelymore » lifted. Here, this approach is particularly suitable for antireflection coatings in the technically challenging terahertz frequency range and is also applicable in other frequency regimes.« less
Low-frequency gravitational wave detection via double optical clocks in space
NASA Astrophysics Data System (ADS)
Su, Jianfeng; Wang, Qiang; Wang, Qinghua; Jetzer, Philippe
2018-04-01
We propose a Doppler tracking system for gravitational wave detection via double optical clocks in space (DOCS). In this configuration two spacecrafts (each containing an optical clock) are launched to space for Doppler shift observations. Compared to the similar attempt of gravitational wave detection in the Cassini mission, the radio signal of DOCS that contains the relative frequency changes avoids completely noise effects due for instance to troposphere, ionosphere, ground-based antenna and transponder. Given the high stabilities of the two optical clocks (Allan deviation ∼ 4.1× 10-17 @ 1000 s), an overall estimated sensitivity of 5 × 10-19 could be achieved with an observation time of 2 yr, and would allow to detect gravitational waves in the frequency range from ∼10‑4 Hz to ∼10‑2 Hz.
The Complete, Temperature Resolved Experimental Spectrum of Methanol (CH3OH) between 560 and 654 GHz
NASA Astrophysics Data System (ADS)
Fortman, Sarah M.; Neese, Christopher F.; De Lucia, Frank C.
2014-02-01
The complete spectrum of methanol (CH3OH) has been characterized over a range of astrophysically significant temperatures in the 560.4-654.0 GHz spectral region. Absolute intensity calibration and analysis of 166 experimental spectra recorded over a slow 248-398 K temperature ramp provide a means for the simulation of the complete spectrum of methanol as a function of temperature. These results include contributions from vt = 3 and other higher states that are difficult to model via quantum mechanical (QM) techniques. They also contain contributions from the 13C isotopologue in terrestrial abundance. In contrast to our earlier work on semi-rigid species, such as ethyl cyanide and vinyl cyanide, significant intensity differences between these experimental values and those calculated by QM methods were found for many of the lines. Analysis of these differences shows the difficulty of the calculation of dipole matrix elements in the context of the internal rotation of the methanol molecule. These results are used to both provide catalogs in the usual line frequency, linestrength, and lower state energy format, as well as in a frequency point-by-point catalog that is particularly well suited for the characterization of blended lines.
Sensitive high frequency hearing in earless and partially eared harlequin frogs (Atelopus).
Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A; Hoke, Kim L
2018-04-19
Harlequin frogs, genus Atelopus , communicate at high frequencies despite most species lacking a complete tympanic middle ear that facilitates high frequency hearing in most anurans and other tetrapods. Here we test whether Atelopus are better at sensing high frequency acoustic sound compared to other eared and earless species in the Bufonidae family, determine whether middle ear variation within Atelopus affects hearing sensitivity, and test potential hearing mechanisms in Atelopus We determine that at high frequencies (2000-4000 Hz) Atelopus are 10-34 dB more sensitive than other earless bufonids but are relatively insensitive to mid-range frequencies (900-1500 Hz) compared to eared bufonids. Hearing among Atelopus species is fairly consistent, evidence that the partial middle ears present in a subset of Atelopus species do not convey a substantial hearing advantage. We further demonstrate that Atelopus hearing is not likely facilitated by vibration of the skin overlying the normal tympanic membrane region or the body lung wall, leaving the extratympanic hearing pathways in Atelopus enigmatic. Together these results show Atelopus have sensitive high frequency hearing without the aid of a tympanic middle ear and prompt further study of extratympanic hearing mechanisms in anurans. © 2018. Published by The Company of Biologists Ltd.
Interaction of proflavine with DNA studied by colloid surface enhanced resonance Raman spectroscopy
NASA Astrophysics Data System (ADS)
Koglin, E.; Séquaris, J.-M.
1986-03-01
The interaction of the mutagenic highly fluourescing proflavine (3,6-diaminoacridine: PF) dye with calf thymus DNA has been studied by Surface Enhanced Resonance Raman Scattering (SERRS). Since the Ag-colloids almost completely quenche the strong fluorescence it is possible to obtain excellent vibrational spectra in a wide frequency range providing valuable information about the intercalation. The intercalation does not affect the vibrational frequencies of the proflavine dye. On the other hand, intensity changes are observed in some of the ring- and NH 2-modes of proflavine upon intercalation. This Raman hypochromism is characteristic for ring stacking interactions and in the SERRS spetroscopy for an additional effects of the dye orientation to the surface.
NASA Technical Reports Server (NTRS)
Angelaki, D. E.
1998-01-01
The three-dimensional (3-D) properties of the translational vestibulo-ocular reflexes (translational VORs) during lateral and fore-aft oscillations in complete darkness were studied in rhesus monkeys at frequencies between 0.16 and 25 Hz. In addition, constant velocity off-vertical axis rotations extended the frequency range to 0.02 Hz. During lateral motion, horizontal responses were in phase with linear velocity in the frequency range of 2-10 Hz. At both lower and higher frequencies, phase lags were introduced. Torsional response phase changed more than 180 degrees in the tested frequency range such that torsional eye movements, which could be regarded as compensatory to "an apparent roll tilt" at the lowest frequencies, became anticompensatory at all frequencies above approximately 1 Hz. These results suggest two functionally different frequency bandwidths for the translational VORs. In the low-frequency spectrum (<<0.5 Hz), horizontal responses compensatory to translation are small and high-pass-filtered whereas torsional response sensitivity is relatively frequency independent. At higher frequencies however, both horizontal and torsional response sensitivity and phase exhibit a similar frequency dependence, suggesting a common role during head translation. During up-down motion, vertical responses were in phase with translational velocity at 3-5 Hz but phase leads progressively increased for lower frequencies (>90 degrees at frequencies <0.2 Hz). No consistent dependence on static head orientation was observed for the vertical response components during up-down motion and the horizontal and torsional response components during lateral translation. The frequency response characteristics of the translational VORs were fitted by "periphery/brain stem" functions that related the linear acceleration input, transduced by primary otolith afferents, to the velocity signals providing the input to the velocity-to-position neural integrator and the oculomotor plant. The lowest-order, best-fit periphery/brain stem model that approximated the frequency dependence of the data consisted of a second order transfer function with two alternating poles (at 0.4 and 7.2 Hz) and zeros (at 0.035 and 3.4 Hz). In addition to clearly differentiator dynamics at low frequencies (less than approximately 0.5 Hz), there was no frequency bandwidth where the periphery/brain stem function could be approximated by an integrator, as previously suggested. In this scheme, the oculomotor plant dynamics are assumed to perform the necessary high-frequency integration as required by the reflex. The detailed frequency dependence of the data could only be precisely described by higher order functions with nonminimum phase characteristics that preclude simple filtering of afferent inputs and might be suggestive of distributed spatiotemporal processing of otolith signals in the translational VORs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKinney, Wayne R.; Howells, M. R.; Yashchuk, V. V.
2008-09-30
An implementation of the two-dimensional statistical scattering theory of Church and Takacs for the prediction of scattering from x-ray mirrors is presented with a graphical user interface. The process of this development has clarified several problems which are of significant interest to the synchrotron community. These problems have been addressed to some extent, for example, for large astronomical telescopes, and at the National Ignition Facility for normal incidence optics, but not in the synchrotron community for grazing incidence optics. Since it is based on the Power Spectral Density (PSD) to provide a description of the deviations from ideal shape ofmore » the surface, accurate prediction of the scattering requires an accurate estimation of the PSD. Specifically, the spatial frequency range of measurement must be the correct one for the geometry of use of the optic--including grazing incidence and coherence effects, and the modifications to the PSD of the Optical Transfer Functions (OTF) of the measuring instruments must be removed. A solution for removal of OTF effects has been presented previously, the Binary Pseudo-Random Grating. Typically, the frequency range of a single instrument does not cover the range of interest, requiring the stitching together of PSD estimations. This combination generates its own set of difficulties in two dimensions. Fitting smooth functions to two dimensional PSDs, particularly in the case of spatial non-isotropy of the surface, which is often the case for optics in synchrotron beam lines, can be difficult. The convenient, and physically accurate fractal for one dimension does not readily transfer to two dimensions. Finally, a completely statistical description of scattering must be integrated with a deterministic low spatial frequency component in order to completely model the intensity near the image. An outline for approaching these problems, and our proposed experimental program is given.« less
The terrestrial gravitational wave environment from known sources
NASA Technical Reports Server (NTRS)
Webbink, Ronald F.
1993-01-01
The objective of this project was to produce a gravitational wave spectral line list of all known binary stars producing expected strain amplitudes at Earth in excess of h = 10 (exp -21), or gravitational wave fluxes in excess of F = 10 (exp -12) erg cm(exp -2) s(exp -1). These strain and flux limits lie above the anticipated detection thresholds for space-borne laser interferometers capable of detecting gravitational radiation in the 10 micron Hz to 1 Hz frequency range. The source list was intended to provide frequency (including each harmonic), amplitude and phase (for each polarization and harmonic), and celestial coordinates for each system, lacking only the orientation of the principal polarization axis with respect to the pole of the coordinate system, and the sign of the source phase and frequency (or, equivalently, of the sense of rotation of the strain tensor with time) from providing a complete source description. Such a spectral line list would lay essential groundwork for high-sensitivity, low-frequency searches for gravitational radiation.
Wave propagation in piezoelectric layered structures of film bulk acoustic resonators.
Zhu, Feng; Qian, Zheng-Hua; Wang, Bin
2016-04-01
In this paper, we studied the wave propagation in a piezoelectric layered plate consisting of a piezoelectric thin film on an electroded elastic substrate with or without a driving electrode. Both plane-strain and anti-plane waves were taken into account for the sake of completeness. Numerical results on dispersion relations, cut-off frequencies and vibration distributions of selected modes were given. The effects of mass ratio of driving electrode layer to film layer on the dispersion curve patterns and cut-off frequencies of the plane-strain waves were discussed in detail. Results show that the mass ratio does not change the trend of dispersion curves but larger mass ratio lowers corresponding frequency at a fixed wave number and may extend the frequency range for energy trapping. Those results are of fundamental importance and can be used as a reference to develop effective two-dimensional plate equations for structural analysis and design of film bulk acoustic resonators. Copyright © 2016 Elsevier B.V. All rights reserved.
A Channelized 2nd IF/LO Downconverter for the E0S Microwave Limb Sounder
NASA Technical Reports Server (NTRS)
LaBelle, Remi C.
2003-01-01
The Earth Observing System (EOS) Microwave Limb Sounder (MLS) is scheduled for launch in 2004 on the EOS Aura spacecraft. The design, assembly and test of the flight 2nd Intermediate Frequency/ Local Oscillator (2nd IF/LO) subsystem for this instrument has been completed and is presented here. The 2nd IF/LO subsystem consists of 5 separate microwave assemblies, 1 for each of the 5 millimeter wave radiometer front ends, providing a total of 33 separate IF channels. Some key requirements of the subsystem are as follows: provide frequency multiplexing of overlapping or closely spaced 1st IF channels while maintaining low ripple in the passbands; generate 19 different 2nd LO frequencies, in the range of 4-20 GHz, with low phase noise and a placement resolution of 400 KHz; downconvert the 1st IF's to a common 2nd IF frequency centered at 900 MHz; minimize cost and schedule by using common designs for the 5 different assemblies wherever possible.
NASA Technical Reports Server (NTRS)
Steffes, P. G.
1986-01-01
The recognition of the need to make laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressure which correspond to the altitudes probed by radio occultation experiments, and over a range of frequencies which correspond to both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. Construction was completed of the outer planets simulator and measurements were conducted of the microwave absorption and refraction from nitrogen under simulated Titan conditions. The results of these and previous laboratory measurements were applied to a wide range of microwave opacity measurements, in order to derive constituent densities and distributions in planetary atmospheres such as Venus.
Spradlin, Alexander
2017-01-01
Objective We created the Daily Sessions, Frequency, Age of Onset, and Quantity of Cannabis Use Inventory (DFAQ-CU) because the current lack of psychometrically sound inventories for measuring these dimensions of cannabis use has impeded research on the effects of cannabis in humans. Method A sample of 2,062 cannabis users completed the DFAQ-CU and was used to assess the DFAQ-CU’s factor structure and reliability. To assess validity, a subsample of 645 participants completed additional measures of cannabis dependence and problems (Marijuana Smoking History Questionnaire [MSHQ], Timeline Followback [TLFB], Cannabis Abuse Screening Test [CAST], Cannabis Use Disorders Identification Test Revised [CUDIT-R], Cannabis Use Problems Identification Test [CUPIT], and Alcohol Use Disorder Identification Test [AUDIT]). Results A six-factor structure was revealed, with factors measuring: daily sessions, frequency, age of onset, marijuana quantity, cannabis concentrate quantity, and edibles quantity. The factors were reliable, with Cronbach’s alpha coefficients ranging from .69 (daily sessions) to .95 (frequency). Results further provided evidence for the factors’ convergent (MSHQ, TLFB), predictive (CAST, CUDIT-R, CUPIT), and discriminant validity (AUDIT). Conclusions The DFAQ-CU is the first psychometrically sound inventory for measuring frequency, age of onset, and quantity of cannabis use. It contains pictures of marijuana to facilitate the measurement of quantity of marijuana used, as well as questions to assess the use of different forms of cannabis (e.g., concentrates, edibles), methods of administering cannabis (e.g., joints, hand pipes, vaporizers), and typical THC levels. As such, the DFAQ-CU should help facilitate research on frequency, quantity, and age of onset of cannabis use. PMID:28552942
Coupled molecular and cantilever dynamics model for frequency-modulated atomic force microscopy.
Klocke, Michael; Wolf, Dietrich E
2016-01-01
A molecular dynamics model is presented, which adds harmonic potentials to the atomic interactions to mimic the elastic properties of an AFM cantilever. It gives new insight into the correlation between the experimentally monitored frequency shift and cantilever damping due to the interaction between tip atoms and scanned surface. Applying the model to ionic crystals with rock salt structure two damping mechanisms are investigated, which occur separately or simultaneously depending on the tip position. These mechanisms are adhesion hysteresis on the one hand and lateral excitations of the cantilever on the other. We find that the short range Lennard-Jones part of the atomic interaction alone is sufficient for changing the predominant mechanism. When the long range ionic interaction is switched off, the two damping mechanisms occur with a completely different pattern, which is explained by the energy landscape for the apex atom of the tip. In this case the adhesion hysteresis is always associated with a distinct lateral displacement of the tip. It is shown how this may lead to a systematic shift between the periodic patterns obtained from the frequency and from the damping signal, respectively.
Work of PZT ceramics sounder for sound source artificial larynx
NASA Astrophysics Data System (ADS)
Sugio, Yuuichi; Kanetake, Ryota; Tanaka, Akimitsu; Ooe, Katsutoshi
2007-04-01
We aim to develop the easy-to-use artificial larynx with high tone quality. We focus on using a PZT ceramics sounder as its sound source, because it is small size, low power consumption, and harmless to humans. But conventional PZT ceramics sounder have the problem that it cannot generate an enough sound in the low frequency range, thus they cannot be used for artificial larynx. Then, we aim to develop the PZT ceramics sounder which can generate enough volume in the low frequency range. If we can lower the resonance frequency of the sounder, it can generate low pitch sound easily. Therefore I created the new diaphragm with low resonance frequency. In addition, we could obtain the high amplitude by changing method of driving. This time, we report on the characteristic comparison of this new PZT ceramics sounder and conventional one. Furthermore, for this new one, we analyzed the best alignment of PZT ceramics and the shape of the diaphragm to obtain low resonance frequency and big amplitude. In fact we analyzed the optimization of the structure. The analysis is done by computer simulation of ANSYS and Laser Doppler Vibrometer. In the future, we will add intonation to the generated sound by input wave form which is developed concurrently, and implant the sounder inside of the body by the method of fixing metal to biomolecule which is done too. And so high tone quality and convenient artificial larynx will be completed.
2009-02-01
range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The corresponding...frequency range of modal analysis and the high frequency region of statistical energy analysis , is referred to as the mid-frequency range. The...predictions. The averaging process is consistent with the averaging done in statistical energy analysis for stochastic systems. The FEM will always
Grosche, Christopher; Funk, Helena T.; Maier, Uwe G.; Zauner, Stefan
2012-01-01
RNA editing is a post-transcriptional process that can act upon transcripts from mitochondrial, nuclear, and chloroplast genomes. In chloroplasts, single-nucleotide conversions in mRNAs via RNA editing occur at different frequencies across the plant kingdom. These range from several hundred edited sites in some mosses and ferns to lower frequencies in seed plants and the complete lack of RNA editing in the liverwort Marchantia polymorpha. Here, we report the sequence and edited sites of the chloroplast genome from the liverwort Pellia endiviifolia. The type and frequency of chloroplast RNA editing display a pattern highly similar to that in seed plants. Analyses of the C to U conversions and the genomic context in which the editing sites are embedded provide evidence in favor of the hypothesis that chloroplast RNA editing evolved to compensate mutations in the first land plants. PMID:23221608
High frequency power distribution system
NASA Technical Reports Server (NTRS)
Patel, Mikund R.
1986-01-01
The objective of this project was to provide the technology of high frequency, high power transmission lines to the 100 kW power range at 20 kHz frequency. In addition to the necessary design studies, a 150 m long, 600 V, 60 A transmission line was built, tested and delivered for full vacuum tests. The configuration analysis on five alternative configurations resulted in the final selection of the three parallel Litz straps configuration, which gave a virtually concentric design in the electromagnetic sense. Low inductance, low EMI and flexibility in handling are the key features of this configuration. The final design was made after a parametric study to minimize the losses, weight and inductance. The construction of the cable was completed with no major difficulties. The R,L,C parameters measured on the cable agreed well with the calculated values. The corona tests on insulation samples showed a safety factor of 3.
Long-pulse-width narrow-bandwidth solid state laser
Dane, C. Brent; Hackel, Lloyd A.
1997-01-01
A long pulse laser system emits 500-1000 ns quasi-rectangular pulses at 527 nm with near diffraction-limited divergence and near transform-limited bandwidth. The system consists of one or more flashlamp-pumped Nd:glass zig-zag amplifiers, a very low threshold stimulated-Brillouin-scattering (SBS) phase conjugator system, and a free-running single frequency Nd:YLF master oscillator. Completely passive polarization switching provides eight amplifier gain passes. Multiple frequency output can be generated by using SBS cells having different pressures of a gaseous SBS medium or different SBS materials. This long pulse, low divergence, narrow-bandwidth, multi-frequency output laser system is ideally suited for use as an illuminator for long range speckle imaging applications. Because of its high average power and high beam quality, this system has application in any process which would benefit from a long pulse format, including material processing and medical applications.
Long-pulse-width narrow-bandwidth solid state laser
Dane, C.B.; Hackel, L.A.
1997-11-18
A long pulse laser system emits 500-1000 ns quasi-rectangular pulses at 527 nm with near diffraction-limited divergence and near transform-limited bandwidth. The system consists of one or more flashlamp-pumped Nd:glass zig-zag amplifiers, a very low threshold stimulated-Brillouin-scattering (SBS) phase conjugator system, and a free-running single frequency Nd:YLF master oscillator. Completely passive polarization switching provides eight amplifier gain passes. Multiple frequency output can be generated by using SBS cells having different pressures of a gaseous SBS medium or different SBS materials. This long pulse, low divergence, narrow-bandwidth, multi-frequency output laser system is ideally suited for use as an illuminator for long range speckle imaging applications. Because of its high average power and high beam quality, this system has application in any process which would benefit from a long pulse format, including material processing and medical applications. 5 figs.
An estimation of global solar p-mode frequencies from IRIS network data: 1989-1996
NASA Astrophysics Data System (ADS)
Serebryanskiy, A.; Ehgamberdiev, Sh.; Kholikov, Sh.; Fossat, E.; Gelly, B.; Schmider, F. X.; Grec, G.; Cacciani, A.; Palle, P. L.; Lazrek, M.; Hoeksema, J. T.
2001-06-01
The IRIS network has accumulated full disk helioseismological data since July 1989, i.e. a complete 11-year solar cycle. Since the last paper publishing a frequency list [A&A 317 (1997) L71], not only has the network acquired new data, but has also developed new co-operative programs with compatible instruments [Abstr. SOHO 6/GONG 98 Workshop (1998) 51], so that merging IRIS files with these co-operative program data sets has made possible the improvement of the overall duty cycle. This paper presents new estimations of low degree p-mode frequencies obtained from this IRIS++ data bank covering the period 1989-1996, as well as the variation of their main parameters along the total range of magnetic activity, from before the last maximum to the very minimum. A preliminary estimation of the peak profile asymmetries is also included.
Pyrotechnic shock measurement and data analysis requirements
NASA Technical Reports Server (NTRS)
Albers, L.
1975-01-01
A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.
A systematic review of community-to-facility neonatal referral completion rates in Africa and Asia.
Kozuki, Naoko; Guenther, Tanya; Vaz, Lara; Moran, Allisyn; Soofi, Sajid B; Kayemba, Christine Nalwadda; Peterson, Stefan S; Bhutta, Zulfiqar A; Khanal, Sudhir; Tielsch, James M; Doherty, Tanya; Nsibande, Duduzile; Lawn, Joy E; Wall, Stephen
2015-09-30
An estimated 2.8 million neonatal deaths occur annually worldwide. The vulnerability of newborns makes the timeliness of seeking and receiving care critical for neonatal survival and prevention of long-term sequelae. To better understand the role active referrals by community health workers play in neonatal careseeking, we synthesize data on referral completion rates for neonates with danger signs predictive of mortality or major morbidity in low- and middle-income countries. A systematic review was conducted in May 2014 of the following databases: Medline-PubMed, Embase, and WHO databases. We also searched grey literature. In addition, an investigator group was established to identify unpublished data on newborn referral and completion rates. Inquiries were made to the network of research groups supported by Save the Children's Saving Newborn Lives project and other relevant research groups. Three Sub-Saharan African and five South Asian studies reported data on community-to-facility referral completion rates. The studies varied on factors such as referral rates, the assessed danger signs, frequency of home visits in the neonatal period, and what was done to facilitate referrals. Neonatal referral completion rates ranged from 34 to 97 %, with the median rate of 74 %. Four studies reported data on the early neonatal period; early neonatal completion rates ranged from 46 to 97 %, with a median of 70 %. The definition of referral completion differed by studies, in aspects such as where the newborns were referred to and what was considered timely completion. Existing literature reports a wide range of neonatal referral completion rates in Sub-Saharan Africa and South Asia following active illness surveillance. Interpreting these referral completion rates is challenging due to the great variation in study design and context. Often, what qualifies as referral and/or referral completion is poorly defined, which makes it difficult to aggregate existing data to draw appropriate conclusions that can inform programs. Further research is necessary to continue highlighting ways for programs, governments, and policymakers to best aid families in low-resource settings in protecting their newborns from major health consequences.
NASA Astrophysics Data System (ADS)
Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Argüeso, F.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Balbi, A.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Bernard, J.-P.; Bersanelli, M.; Bethermin, M.; Bhatia, R.; Bonaldi, A.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Cabella, P.; Cardoso, J.-F.; Catalano, A.; Cayón, L.; Chamballu, A.; Chary, R.-R.; Chen, X.; Chiang, L.-Y.; Christensen, P. R.; Clements, D. L.; Colafrancesco, S.; Colombi, S.; Colombo, L. P. L.; Coulais, A.; Crill, B. P.; Cuttaia, F.; Danese, L.; Davis, R. J.; de Bernardis, P.; de Gasperis, G.; de Zotti, G.; Delabrouille, J.; Dickinson, C.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Dörl, U.; Douspis, M.; Dupac, X.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Finelli, F.; Forni, O.; Fosalba, P.; Frailis, M.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K. M.; Gregorio, A.; Gruppuso, A.; Hansen, F. K.; Harrison, D.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Jaffe, T. R.; Jaffe, A. H.; Jagemann, T.; Jones, W. C.; Juvela, M.; Keihänen, E.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurinsky, N.; Kurki-Suonio, H.; Lagache, G.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lawrence, C. R.; Leonardi, R.; Lilje, P. B.; López-Caniego, M.; Macías-Pérez, J. F.; Maino, D.; Mandolesi, N.; Maris, M.; Marshall, D. J.; Martínez-González, E.; Masi, S.; Massardi, M.; Matarrese, S.; Mazzotta, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Mitra, S.; Miville-Deschènes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Pajot, F.; Paladini, R.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G. W.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reach, W. T.; Rebolo, R.; Reinecke, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rowan-Robinson, M.; Rubiño-Martín, J. A.; Rusholme, B.; Sajina, A.; Sandri, M.; Savini, G.; Scott, D.; Smoot, G. F.; Starck, J.-L.; Sudiwala, R.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Türler, M.; Valenziano, L.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L. A.; Wandelt, B. D.; White, M.; Yvon, D.; Zacchei, A.; Zonca, A.
2013-02-01
We make use of the Planck all-sky survey to derive number counts and spectral indices of extragalactic sources - infrared and radio sources - from the Planck Early Release Compact Source Catalogue (ERCSC) at 100 to 857 GHz (3 mm to 350 μm). Three zones (deep, medium and shallow) of approximately homogeneous coverage are used to permit a clean and controlled correction for incompleteness, which was explicitly not done for the ERCSC, as it was aimed at providing lists of sources to be followed up. Our sample, prior to the 80% completeness cut, contains between 217 sources at 100 GHz and 1058 sources at 857 GHz over about 12 800 to 16 550 deg2 (31 to 40% of the sky). After the 80% completeness cut, between 122 and 452 and sources remain, with flux densities above 0.3 and 1.9 Jy at 100 and 857 GHz. The sample so defined can be used for statistical analysis. Using the multi-frequency coverage of the Planck High Frequency Instrument, all the sources have been classified as either dust-dominated (infrared galaxies) or synchrotron-dominated (radio galaxies) on the basis of their spectral energy distributions (SED). Our sample is thus complete, flux-limited and color-selected to differentiate between the two populations. We find an approximately equal number of synchrotron and dusty sources between 217 and 353 GHz; at 353 GHz or higher (or 217 GHz and lower) frequencies, the number is dominated by dusty (synchrotron) sources, as expected. For most of the sources, the spectral indices are also derived. We provide for the first time counts of bright sources from 353 to 857 GHz and the contributions from dusty and synchrotron sources at all HFI frequencies in the key spectral range where these spectra are crossing. The observed counts are in the Euclidean regime. The number counts are compared to previously published data (from earlier Planck results, Herschel, BLAST, SCUBA, LABOCA, SPT, and ACT) and models taking into account both radio or infrared galaxies, and covering a large range of flux densities. We derive the multi-frequency Euclidean level - the plateau in the normalised differential counts at high flux-density - and compare it to WMAP, Spitzer and IRAS results. The submillimetre number counts are not well reproduced by current evolution models of dusty galaxies, whereas the millimetre part appears reasonably well fitted by the most recent model for synchrotron-dominated sources. Finally we provide estimates of the local luminosity density of dusty galaxies, providing the first such measurements at 545 and 857 GHz. Appendices are available in electronic form at http://www.aanda.orgCorresponding author: herve.dole@ias.u-psud.fr
Terahertz multiheterodyne spectroscopy using laser frequency combs
Yang, Yang; Burghoff, David; Hayton, Darren J.; ...
2014-07-01
The terahertz region is of great importance for spectroscopy since many molecules have absorption fingerprints there. Frequency combs based on terahertz quantum cascade lasers feature broadband coverage and high output powers in a compact package, making them an attractive option for broadband spectroscopy. Here, we demonstrate the first multiheterodyne spectroscopy using two terahertz quantum cascade laser combs. Over a spectral range of 250 GHz, we achieve average signal-to-noise ratios of 34 dB using cryogenic detectors and 24 dB using room-temperature detectors, all in just 100 μs. As a proof of principle, we use these combs to measure the broadband transmissionmore » spectrum of etalon samples and show that, with proper signal processing, it is possible to extend the multiheterodyne spectroscopy to quantum cascade laser combs operating in pulsed mode. Here, this greatly expands the range of quantum cascade lasers that could be suitable for these techniques and allows for the creation of completely solid-state terahertz laser spectrometers.« less
Frequency of debridements and time to heal: a retrospective cohort study of 312 744 wounds.
Wilcox, James R; Carter, Marissa J; Covington, Scott
2013-09-01
Chronic wounds usually get trapped in the inflammatory stage of wound healing; however, aggressive debridement transforms chronic wounds to acute wounds and therefore complete healing. To investigate healing outcomes and debridement frequency in a large wound data set. Retrospective cohort study. Data collected from 525 wound care centers from June 1, 2008, through June 31, 2012, using a web-based clinical management system. Referred sample of 154 644 patients with 312 744 wounds of all causes (of an initial data set of 364 534 wounds) participated. A total of 47.1% were male. Median age was 69 years (age range, 19-112 years), with 59.2% having one wound. Eligibility criteria included age older than 18 years, receiving at least 1 debridement, and having been discharged from the system. Advanced therapeutic treatment was ineligible. Because of incomplete, questionable, or ineligible data, 57 190 wounds were not included. Most wounds were diabetic foot ulcers (19.0%), venous leg ulcers (26.1%), and pressure ulcers (16.2%). Debridement (removal of necrotic tissue and foreign bodies from the wound) at different frequencies. Wound healing (completely epithelialized with dimensions at 0 × 0 × 0 cm). A total of 70.8% of wounds healed. The median number of debridements was 2 (range, 1-138). Frequent debridement healed more wounds in a shorter time (P < .001). In regression analysis, significant variables included male sex, physician category, wound type, increased patient age, and increased wound age, area, and depth. The odds ratio varied considerably for each variable. The more frequent the debridements, the better the healing outcome. Although limited by retrospective data, this study's strength was the analysis of the largest wound data set to date.
Greenfield, Thomas K.; Kerr, William C.; Bond, Jason; Ye, Yu; Stockwell, Tim
2009-01-01
We investigate several types of graduated frequency (GF) instruments for monitoring drinking patterns. Two studies with 12-month GF measures and daily data were used: (i) the Australian 2004 National Drug Strategy Household Survey (n = 24,109 aged 12+; 22,546 with GF and over 8000 with yesterday data) and (ii) a US methodological study involving a 28-day daily diary plus GF summary measures drawn from the National Alcohol Survey (n = 3,025 screened, 119 eligible study completers). The NDSHS involved (i) “drop and collect” self-completed forms with random sampling methods; the Measurement study (ii) screened 3+ drinkers by telephone and collected 28-day drinking diaries and pre- and post-diary 28-day GFs. We compared mean values for the GF quantity ranges from yesterday’s drinks (study i) and 28-day diaries (study ii), also examining volume influence. Using Yesterday’s drinking, Australian results showed GF quantity range means close to arithmetic midpoints and volume effects only for the lowest two levels (1–2, and 3–4 drinks; p < .001). U.S. calibration results on the GF using 28-day diaries were similar, with a volume effect only at these low quantity levels (p < .001). Means for the highest quantity thresholds were 23.5 drinks for the 20+ (10 gram) drink level (Australia) and 15.5 drinks for the 12+ (14 g) drink level (US). In the US study, summary GF frequency and volume were highly consistent with diary-based counterparts. A conclusion is that algorithms for computing volume may be refined using validation data. We suggest measurement methods may be improved by taking better account of empirical drink ethanol content. PMID:21197381
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hai-Feng, E-mail: hanlor@163.com; Nanjing Artillery Academy, Nanjing 211132; Ding, Guo-Wen
2015-02-15
In this paper, the properties of complete photonic band gaps (CPBGs) and tunable self-collimation in two-dimensional plasma photonic crystals (2D PPCs) with a new structure in square lattices, whose dielectric fillers (GaAs) are inserted into homogeneous and nomagnetized plasma background are theoretically investigated by a modified plane wave expansion (PWE) method with a novel technique. The novel PWE method can be utilized to compute the dispersion curves of 2D PPCs with arbitrary-shaped cross section in any lattices. As a comparison, CPBGs of PPCs for four different configurations are numerically calculated. The computed results show that the proposed design has themore » advantages of achieving the larger CPBGs compared to the other three configurations. The influences of geometric parameters of filled unit cell and plasma frequency on the properties of CPBGs are studied in detail. The calculated results demonstrate that CPBGs of the proposed 2D PPCs can be easily engineered by changing those parameters, and the larger CPBGs also can be obtained by optimization. The self-collimation in such 2D PPCs also is discussed in theory under TM wave. The theoretical simulations reveal that the self-collimation phenomena can be found in the TM bands, and both the frequency range of self-collimation and the equifrequency surface contours can be tuned by the parameters as mentioned above. It means that the frequency range and direction of electromagnetic wave can be manipulated by designing, as it propagates in the proposed PPCs without diffraction. Those results can hold promise for designing the tunable applications based on the proposed PPCs.« less
47 CFR 18.309 - Frequency range of measurements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MEDICAL EQUIPMENT Technical Standards § 18.309 Frequency range of measurements. (a) For field strength measurements: Frequency band in which device operates (MHz) Range of frequency measurements Lowest frequency...
Crupi, Vincenza; Fontana, Aldo; Giarola, Marco; Guella, Graziano; Majolino, Domenico; Mancini, Ines; Mariotto, Gino; Paciaroni, Alessandro; Rossi, Barbara; Venuti, Valentina
2013-04-11
The effect of the inclusion into cyclodextrins (CD) cavity on the low-frequency vibrational dynamics of the anti-inflammatory drug ibuprofen (IBP) is here investigated by using Raman and inelastic neutron scattering (INS) experiments. The differences observed in the frequency regime 0-100 cm(-1) between the vibrational modes of uncomplexed racemic and enantiomeric IBP are discussed on the basis of comparison with the quantum chemical computation results, taking into account the distinct symmetry properties of the molecules involved in the formation of the host-guest complex. Subsequently, the inspection of the same frequency range in the spectra of pure host methyl-β-CD and its IBP-inclusion complexes allows one to identify significant modifications in the vibrational dynamics of the guest molecule after their confinement into CD cavity. The experimental Raman and neutron spectra and the derived Raman coupling function C(R)(ω) show that the complexation process gives rise to a complete amorphization of the drug, as well as to a partial hindering, in the vibrational dynamics of complexes, of the modes between 50 and 150 cm(-1) attributed to CD molecule. The comparison between the Raman and neutron spectra of free and complexed IBP in the energy range of the Boson peak (BP) gives evidence that the dynamics related to this specific vibrational feature is sensitive to complexation phenomena.
High Precision Ranging and Range-Rate Measurements over Free-Space-Laser Communication Link
NASA Technical Reports Server (NTRS)
Yang, Guangning; Lu, Wei; Krainak, Michael; Sun, Xiaoli
2016-01-01
We present a high-precision ranging and range-rate measurement system via an optical-ranging or combined ranging-communication link. A complete bench-top optical communication system was built. It included a ground terminal and a space terminal. Ranging and range rate tests were conducted in two configurations. In the communication configuration with 622 data rate, we achieved a two-way range-rate error of 2 microns/s, or a modified Allan deviation of 9 x 10 (exp -15) with 10 second averaging time. Ranging and range-rate as a function of Bit Error Rate of the communication link is reported. They are not sensitive to the link error rate. In the single-frequency amplitude modulation mode, we report a two-way range rate error of 0.8 microns/s, or a modified Allan deviation of 2.6 x 10 (exp -15) with 10 second averaging time. We identified the major noise sources in the current system as the transmitter modulation injected noise and receiver electronics generated noise. A new improved system will be constructed to further improve the system performance for both operating modes.
Pashankar, Dinesh S; Bishop, Warren P; Loening-Baucke, Vera
2003-01-01
Seventy-four children (43 with chronic constipation, 31 with constipation and encopresis) treated with polyethylene glycol 3350 (PEG) for longer than 3 months were studied to assess long-term efficacy. The mean duration of PEG therapy was 8.4 months (range, 3-30). Weekly stool frequency, stool consistency, and symptoms associated with constipation improved significantly with PEG therapy in all 74 patients. In 31 children with encopresis, soiling ceased completely in 16 patients and frequency of soiling decreased significantly in all others. The average effective long-term dose of PEG was 0.7 g/kg/day. Long-term PEG therapy is effective for the treatment of chronic constipation with and without encopresis in children.
The study of electrical conduction mechanisms. [dielectric response of lunar fines
NASA Technical Reports Server (NTRS)
Morrison, H. F.
1974-01-01
The dielectric response of lunar fines 74241,2 is presented in the audio-frequency range and under lunarlike conditions. Results suggest that volatiles are released during storage and transport of the lunar sample. Apparently, subsequent absorption of volatiles on the sample surface alter its dielectric response. The assumed volatile influence disappear after evacuation. A comparison of the dielectric properties of lunar and terrestrial materials as a function of density, temperature, and frequency indicates that if the lunar simulator analyzed were completely devoid of atmospheric moisture it would present dielectric losses smaller than those of the lunar sample. It is concluded that density prevails over temperature as the controlling factor of dielectric permittivity in the lunar regolith and that dielectric losses vary slowly with depth.
Characteristics of different frequency ranges in scanning electron microscope images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.
2015-07-22
We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.
A practical, low-noise coil system for magnetotellurics
Stanley, William D.; Tinkler, Richard D.
1983-01-01
Magnetotellurics is a geophysical technique which was developed by Cagnaird (1953) and Tikhonov (1950) and later refined by other scientists worldwide. The technique is a method of electromagnetic sounding of the Earth and is based upon the skin depth effect in conductive media. The electric and magnetic fields arising from natural sources are measured at the surface of the earth over broad frequency bands. An excellent review of the technique is provided in the paper by Vozoff (1972). The sources of the natural fields are found in two basic mechanisms. At frequencies above a few hertz, most of the energy arises from lightning in thunderstorm belts around the equatorial regions. This energy is propagated in a wave-guide formed by the earthionospheric cavity. Energy levels are higher at fundamental modes for this cavity, but sufficient energy exists over most of the audio range to be useful for sounding at these frequencies, in which case the technique is generally referred to as audio-magnetotellurics or AMT. At frequencies lower than audio, and in general below 1 Hz, the source of naturally occuring electromagnetic energy is found in ionospheric currents. Current systems flowing in the ionosphere generate EM waves which can be used in sounding of the earth. These fields generate a relatively complete spectrum of electromagnetic energy that extends from around 1 Hz to periods of one day. Figure 1 shows an amplitude spectrum characteristic of both the ionospheric and lightning sources, covering a frequency range from 0.0001 Hz to 1000 Hz. It can be seen that there is a minimum in signal levels that occurs at about 1 Hz, in the gap between the two sources, and that signal level increases with a decrease in frequency.
Harden, Cynthia L; Herzog, Andrew G; Nikolov, Blagovest G; Koppel, Barbara S; Christos, Paul J; Fowler, Kristen; Labar, Douglas R; Hauser, W Allen
2006-09-01
Previous reports have suggested that hormone replacement therapy (HRT) could increase seizure activity in women with epilepsy. We sought to determine whether adding HRT to the medication regimen of postmenopausal women with epilepsy was associated with an increase in seizure frequency. This was a randomized, double-blind, placebo-controlled trial of the effect of HRT on seizure frequency in postmenopausal women with epilepsy, taking stable doses of antiepileptic drugs (AEDs), and within 10 years of their last menses. After a 3-month prospective baseline, subjects were randomized to placebo, Prempro (0.625 mg of conjugated equine estrogens plus 2.5 mg of medroxyprogesterone acetate or CEE/MPA) daily, or double-dose CEE/MPA daily for a 3-month treatment period. Twenty-one subjects were randomized after completing baseline. The subjects' ages ranged from 45 to 62 years (mean, 53 years; SD, +/-5), and the number of AEDs used ranged from none to three (median, one). Five (71%) of seven subjects taking double-dose CEE/MPA had a worsening seizure frequency of at least one seizure type, compared with four (50%) of eight taking single-dose CEE/MPA and one (17%) of six taking placebo (p = 0.05). An increase in seizure frequency of the subject's most severe seizure type was associated with increasing CEE/MPA dose (p = 0.008). An increase in complex partial seizure frequency also was associated with increasing CEE/MPA dose (p = 0.05). Two subjects taking lamotrigine had a decrease in lamotrigine levels of 25-30% while taking CEE/MPA. CEE/MPA is associated with a dose-related increase in seizure frequency in postmenopausal women with epilepsy. CEE/MPA may decrease lamotrigine levels.
Perlis, Nathan; Lo, Kirk C; Grober, Ethan D; Spencer, Leia; Jarvi, Keith
2013-08-01
To determine the coital frequency among infertile couples and which factors are associated with less frequent coitus. Cross-sectional study. Tertiary-level male infertility clinic. A total of 1,298 infertile men. Administration of computer-based survey, semen analysis, and serum hormone evaluation. Monthly coital frequency. A total of 1,298 patients presented to clinic for infertility consultation and completed the computer-based survey. The median male age was 35 years (interquartile range [IQR] 32-39 years) and the median duration of infertility was 2 years (IQR 1-4 years) before consultation. Median monthly coital frequency was seven (IQR 5-10; range 0-40); 24% of couples were having intercourse ≤ 4 times per month. Overall, 0.6%, 2.7%, 4.8%, 5.8%, and 10.8% of the men reported having intercourse 0, 1, 2, 3, and 4 times per month, respectively. When simultaneously taking into account the influence of age, libido, erectile function, and semen volume on coital frequency, older patients had 1.05 times higher odds (per year of age) of less frequent coitus (odds ratio 1.05, 95% confidence interval 1.03-1.08). In addition, patients with better erectile function had 1.12 times higher odds (per point on Sexual Health Inventory for Men scale) of more frequent coitus (odds ratio 1.12, 95% confidence interval 1.09-1.18). Similar to the general population, most infertile couples report having coitus more than four times per month. Older male age and erectile dysfunction are independent risk factors for less frequent coitus among infertile men, which could have an impact on fertility. Coital frequency should be considered in infertility assessments. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
The ISEE-C plasma wave investigation
NASA Technical Reports Server (NTRS)
Scarf, F. L.; Fredricks, R. W.; Gurnett, D. A.; Smith, E. J.
1978-01-01
The ISEE-C plasma wave investigation is designed to provide comprehensive information on interplanetary wave-particle interactions. Three spectrum analyzers with a total of 19 bandpass channels cover the frequency range 0.3 Hz to 100 kHz. The main analyzer, which uses 16 continuously active amplifiers, gives two complete spectral scans per second in each of 16 filter channels. The instrument sensors include a high-sensitivity magnetic search coil, and electric antennas with effective lengths of 0.6 and 45 m.
Ultrasonic determination of recrystallization
NASA Technical Reports Server (NTRS)
Generazio, E. R.
1986-01-01
Ultrasonic attenuation was measured for cold worked Nickel 200 samples annealed at increasing temperatures. Localized dislocation density variations, crystalline order and colume percent of recrystallized phase were determined over the anneal temperature range using transmission electron microscopy, X-ray diffraction, and metallurgy. The exponent of the frequency dependence of the attenuation was found to be a key variable relating ultrasonic attenuation to the thermal kinetics of the recrystallization process. Identification of this key variable allows for the ultrasonic determination of onset, degree, and completion of recrystallization.
A Web-Based Graphical Food Frequency Assessment System: Design, Development and Usability Metrics.
Franco, Rodrigo Zenun; Alawadhi, Balqees; Fallaize, Rosalind; Lovegrove, Julie A; Hwang, Faustina
2017-05-08
Food frequency questionnaires (FFQs) are well established in the nutrition field, but there remain important questions around how to develop online tools in a way that can facilitate wider uptake. Also, FFQ user acceptance and evaluation have not been investigated extensively. This paper presents a Web-based graphical food frequency assessment system that addresses challenges of reproducibility, scalability, mobile friendliness, security, and usability and also presents the utilization metrics and user feedback from a deployment study. The application design employs a single-page application Web architecture with back-end services (database, authentication, and authorization) provided by Google Firebase's free plan. Its design and responsiveness take advantage of the Bootstrap framework. The FFQ was deployed in Kuwait as part of the EatWellQ8 study during 2016. The EatWellQ8 FFQ contains 146 food items (including drinks). Participants were recruited in Kuwait without financial incentive. Completion time was based on browser timestamps and usability was measured using the System Usability Scale (SUS), scoring between 0 and 100. Products with a SUS higher than 70 are considered to be good. A total of 235 participants created accounts in the system, and 163 completed the FFQ. Of those 163 participants, 142 reported their gender (93 female, 49 male) and 144 reported their date of birth (mean age of 35 years, range from 18-65 years). The mean completion time for all FFQs (n=163), excluding periods of interruption, was 14.2 minutes (95% CI 13.3-15.1 minutes). Female participants (n=93) completed in 14.1 minutes (95% CI 12.9-15.3 minutes) and male participants (n=49) completed in 14.3 minutes (95% CI 12.6-15.9 minutes). Participants using laptops or desktops (n=69) completed the FFQ in an average of 13.9 minutes (95% CI 12.6-15.1 minutes) and participants using smartphones or tablets (n=91) completed in an average of 14.5 minutes (95% CI 13.2-15.8 minutes). The median SUS score (n=141) was 75.0 (interquartile range [IQR] 12.5), and 84% of the participants who completed the SUS classified the system either "good" (n=50) or "excellent" (n=69). Considering only participants using smartphones or tablets (n=80), the median score was 72.5 (IQR 12.5), slightly below the SUS median for desktops and laptops (n=58), which was 75.0 (IQR 12.5). No significant differences were found between genders or age groups (below and above the median) for the SUS or completion time. Taking into account all the requirements, the deployment used professional cloud computing at no cost, and the resulting system had good user acceptance. The results for smartphones/tablets were comparable with desktops/laptops. This work has potential to promote wider uptake of online tools that can assess dietary intake at scale. ©Rodrigo Zenun Franco, Balqees Alawadhi, Rosalind Fallaize, Julie A Lovegrove, Faustina Hwang. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 08.05.2017.
Midha, Anita; Dearden, Simon; McCormack, Rose
2015-01-01
Mutations in the epidermal growth factor receptor (EGFR) gene are commonly observed in non-small-cell lung cancer (NSCLC), particularly in tumors of adenocarcinoma (ADC) histology (NSCLC/ADC). Robust data exist regarding the prevalence of EGFR mutations in Western and Asian patients with NSCLC/ADC, yet there is a lack of data for patients of other ethnicities. This review collated available data with the aim of creating a complete, global picture of EGFR mutation frequency in patients with NSCLC/ADC by ethnicity. Worldwide literature reporting EGFR mutation frequency in patients with NSCLC/ADC was reviewed, to create a map of the world populated with EGFR mutation frequency by country (a ‘global EGFR mutMap’). A total of 151 worldwide studies (n=33162 patients with NSCLC/ADC, of which 9749 patients had EGFR mutation-positive NSCLC/ADC) were included. There was substantial variation in EGFR mutation frequency between studies, even when grouped by geographic region or individual country. As expected, the Asia-Pacific NSCLC/ADC subgroup had the highest EGFR mutation frequency (47% [5958/12819; 87 studies; range 20%-76%]) and the lowest EGFR mutation frequency occurred in the Oceania NSCLC/ADC subgroup (12% [69/570; 4 studies; range 7%-36%]); however, comparisons between regions were limited due to the varying sizes of the patient populations studied. In all regional (geographic) subgroups where data were available, EGFR mutation frequency in NSCLC/ADC was higher in women compared with men, and in never-compared with ever-smokers. This review provides the foundation for a global map of EGFR mutation frequency in patients with NSCLC/ADC. The substantial lack of data from several large geographic regions of the world, notably Africa, the Middle East, Central Asia, and Central and South America, highlights a potential lack of routine mutation testing and the need for further investigations in these regions. PMID:26609494
Leicht, Gregor; Troschütz, Stefan; Andreou, Christina; Karamatskos, Evangelos; Ertl, Matthias; Naber, Dieter; Mulert, Christoph
2013-01-01
The processing of reward and punishment stimuli in humans appears to involve brain oscillatory activity of several frequencies, probably each with a distinct function. The exact nature of associations of these electrophysiological measures with impulsive or risk-seeking personality traits is not completely clear. Thus, the aim of the present study was to investigate event-related oscillatory activity during reward processing across a wide spectrum of frequencies, and its associations with impulsivity and sensation seeking in healthy subjects. During recording of a 32-channel EEG 22 healthy volunteers were characterized with the Barratt Impulsiveness and the Sensation Seeking Scale and performed a computerized two-choice gambling task comprising different feedback options with positive vs. negative valence (gain or loss) and high or low magnitude (5 vs. 25 points). We observed greater increases of amplitudes of the feedback-related negativity and of activity in the theta, alpha and low-beta frequency range following loss feedback and, in contrast, greater increase of activity in the high-beta frequency range following gain feedback. Significant magnitude effects were observed for theta and delta oscillations, indicating greater amplitudes upon feedback concerning large stakes. The theta amplitude changes during loss were negatively correlated with motor impulsivity scores, whereas alpha and low-beta increase upon loss and high-beta increase upon gain were positively correlated with various dimensions of sensation seeking. The findings suggest that the processing of feedback information involves several distinct processes, which are subserved by oscillations of different frequencies and are associated with different personality traits.
Selective Impairment in Frequency Discrimination in a Mouse Model of Tinnitus
Mwilambwe-Tshilobo, Laetitia; Davis, Andrew J. O.; Aizenberg, Mark; Geffen, Maria N.
2015-01-01
Tinnitus is an auditory disorder, which affects millions of Americans, including active duty service members and veterans. It is manifested by a phantom sound that is commonly restricted to a specific frequency range. Because tinnitus is associated with hearing deficits, understanding how tinnitus affects hearing perception is important for guiding therapies to improve the quality of life in this vast group of patients. In a rodent model of tinnitus, prolonged exposure to a tone leads to a selective decrease in gap detection in specific frequency bands. However, whether and how hearing acuity is affected for sounds within and outside those frequency bands is not well understood. We induced tinnitus in mice by prolonged exposure to a loud mid-range tone, and behaviorally assayed whether mice exhibited a change in frequency discrimination acuity for tones embedded within the mid-frequency range and high-frequency range at 1, 4, and 8 weeks post-exposure. A subset of tone-exposed mice exhibited tinnitus-like symptoms, as demonstrated by selective deficits in gap detection, which were restricted to the high frequency range. These mice exhibited impaired frequency discrimination both for tones in the mid-frequency range and high-frequency range. The remaining tone exposed mice, which did not demonstrate behavioral evidence of tinnitus, showed temporary deficits in frequency discrimination for tones in the mid-frequency range, while control mice remained unimpaired. Our findings reveal that the high frequency-specific deficits in gap detection, indicative of tinnitus, are associated with impairments in frequency discrimination at the frequency of the presumed tinnitus. PMID:26352864
Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill
2016-07-01
To compare the frequency of atraumatic ligamentum teres (LT) tear in professional ballet dancers with that of athletes, and to determine the relationship with clinical and imaging findings. Forty-nine male and female professional ballet dancers (98 hips) and 49 age and sex-matched non-dancing athletes (98 hips) completed questionnaires on hip symptoms and physical activity levels, underwent hip rotation range of movement (ROM) and hypermobility testing, and 3.0-Tesla magnetic resonance imaging (3 T MRI) on both hips to detect LT tears, acetabular labral tears, and articular cartilage defects, and to measure the lateral centre edge angles (LCE). A higher frequency of LT tear was found in dancers (55 %) compared with athletes (22 %, P = 0.001). The frequency and severity of LT tears in dancers increased with older age (P = 0.004, P = 0.006, respectively). The Hip and Groin Outcome Score (HAGOS) pain scores or hip rotation ROM did not differ significantly among participants with normal, partial, or complete tears of LT (P > 0.01 for all). Neither the frequency of generalised joint hypermobility (P = 0.09) nor the LCE angles (P = 0.32, P = 0.16, left and right hips respectively) differed between those with and those without LT tear. In most hips, LT tear co-existed with either a labral tear or a cartilage defect, or both. The higher frequency of atraumatic LT tears in professional ballet dancers suggests that the LT might be abnormally loaded in ballet, and caution is required when evaluating MRI, as LT tears may be asymptomatic. A longitudinal study of this cohort is required to determine if LT tear predisposes the hip joint to osteoarthritis.
Implicit causality bias in English: a corpus of 300 verbs.
Ferstl, Evelyn C; Garnham, Alan; Manouilidou, Christina
2011-03-01
This study provides implicit verb causality norms for a corpus of 305 English verbs. A web-based sentence completion study was conducted, with 96 respondents completing fragments such as "John liked Mary because..." The resulting bias scores are provided as supplementary material in the Psychonomic Society Archive, where we also present lexical and semantic verb features, such as the frequency, semantic class and emotional valence. Our results replicate those of previous studies with much smaller numbers of verbs and respondents. Novel effects of gender and its interaction with verb valence illustrate the type of issues that can be investigated using stable norms for a large number of verbs. The corpus will facilitate future studies in a range of areas, including psycholinguistics and social psychology.
Variable frequency iteration MPPT for resonant power converters
Zhang, Qian; Bataresh, Issa; Chen, Lin
2015-06-30
A method of maximum power point tracking (MPPT) uses an MPPT algorithm to determine a switching frequency for a resonant power converter, including initializing by setting an initial boundary frequency range that is divided into initial frequency sub-ranges bounded by initial frequencies including an initial center frequency and first and second initial bounding frequencies. A first iteration includes measuring initial powers at the initial frequencies to determine a maximum power initial frequency that is used to set a first reduced frequency search range centered or bounded by the maximum power initial frequency including at least a first additional bounding frequency. A second iteration includes calculating first and second center frequencies by averaging adjacent frequent values in the first reduced frequency search range and measuring second power values at the first and second center frequencies. The switching frequency is determined from measured power values including the second power values.
Classical investigation of long-range coherence in biological systems
NASA Astrophysics Data System (ADS)
Preto, Jordane
2016-12-01
Almost five decades ago, H. Fröhlich [H. Fröhlich, "Long-range coherence and energy storage in biological systems," Int. J. Quantum Chem. 2(5), 641-649 (1968)] reported, on a theoretical basis, that the excitation of quantum modes of vibration in contact with a thermal reservoir may lead to steady states, where under high enough rate of energy supply, only specific low-frequency modes of vibration are strongly excited. This nonlinear phenomenon was predicted to occur in biomolecular systems, which are known to exhibit complex vibrational spectral properties, especially in the terahertz frequency domain. However, since the effects of terahertz or lower-frequency modes are mainly classical at physiological temperatures, there are serious doubts that Fröhlich's quantum description can be applied to predict such a coherent behavior in a biological environment, as suggested by the author. In addition, a quantum formalism makes the phenomenon hard to investigate using realistic molecular dynamics simulations (MD) as they are usually based on the classical principles. In the current paper, we provide a general classical Hamiltonian description of a nonlinear open system composed of many degrees of freedom (biomolecular structure) excited by an external energy source. It is shown that a coherent behaviour similar to Fröhlich's effect is to be expected in the classical case for a given range of parameter values. Thus, the supplied energy is not completely thermalized but stored in a highly ordered fashion. The connection between our Hamiltonian description, carried out in the space of normal modes, and a more standard treatment in the physical space is emphasized in order to facilitate the prediction of the effect from MD simulations. It is shown how such a coherent phenomenon may induce long-range resonance effects that could be of critical importance at the biomolecular level. The present work is motivated by recent experimental evidences of long-lived excited low-frequency modes in protein structures, which were reported as a consequence of the Fröhlich's effect.
Site-specific Microzonation Study in Delhi Metropolitan City by 2-D Modelling of SH and P-SV Waves
NASA Astrophysics Data System (ADS)
Parvez, Imtiyaz A.; Vaccari, F.; Panza, G. F.
Delhi - the capital of India lies on a severe earthquake hazard threat not only from local earthquakes but also from Himalayan events just 200-250 km apart. The seismic ground motion in a part of Delhi City is computed with a hybrid technique based on the modal summation and the finite-difference scheme for site-specific strong ground motion modelling. Complete realistic SH and #E5/E5#-SV wave seismograms are computed along two geological cross sections, (1) north-south, from Inter State Bus Terminal (ISBT) to Sewanagar and (2) east-west, from Tilak Bridge to Punjabi Bagh. Two real earthquake sources of July 15, 1720 (MMI=IX, M=7.4) and August 27, 1960 (M=6.0) have been used in modelling. The response spectra ratio (RSR), i.e. the response spectra computed from the signals synthesized along the laterally varying section and normalized by the response spectra computed from the corresponding signals, synthesized for the bedrock reference regional model, have been determined. As expected, the sedimentary cover causes an increase of the signal amplitude, particularly in the radial and transverse components. To further check the site-effects, we reversed the source location to the other side of the cross section and recomputed the site amplifications. There are only a few sites where a large amplification is invariant with respect to the two source locations considered. The RSR ranges between 5 to 10 in the frequency range from 2.8 to 3.7 Hz for the radial and transverse components of motion along the NS cross section. Along the EW cross section RSR varies between 3.5 to 7.5 in the frequency range from 3.5 to 4.1 Hz. The amplification of the vertical component is considerable at high frequency (>4 Hz.) whereas it is negligible in lower frequency range.
FREQUENCY DEPENDENCE OF POLARIZATION OF ZEBRA PATTERN IN TYPE-IV SOLAR RADIO BURSTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaneda, Kazutaka; Misawa, H.; Tsuchiya, F.
2015-08-01
We investigated the polarization characteristics of a zebra pattern (ZP) in a type-IV solar radio burst observed with AMATERAS on 2011 June 21 for the purpose of evaluating the generation processes of ZPs. Analyzing highly resolved spectral and polarization data revealed the frequency dependence of the degree of circular polarization and the delay between two polarized components for the first time. The degree of circular polarization was 50%–70% right-handed and it varied little as a function of frequency. Cross-correlation analysis determined that the left-handed circularly polarized component was delayed by 50–70 ms relative to the right-handed component over the entiremore » frequency range of the ZP and this delay increased with the frequency. We examined the obtained polarization characteristics by using pre-existing ZP models and concluded that the ZP was generated by the double-plasma-resonance process. Our results suggest that the ZP emission was originally generated in a completely polarized state in the O-mode and was partly converted into the X-mode near the source. Subsequently, the difference between the group velocities of the O-mode and X-mode caused the temporal delay.« less
A deterministic (non-stochastic) low frequency method for geoacoustic inversion.
Tolstoy, A
2010-06-01
It is well known that multiple frequency sources are necessary for accurate geoacoustic inversion. This paper presents an inversion method which uses the low frequency (LF) spectrum only to estimate bottom properties even in the presence of expected errors in source location, phone depths, and ocean sound-speed profiles. Matched field processing (MFP) along a vertical array is used. The LF method first conducts an exhaustive search of the (five) parameter search space (sediment thickness, sound-speed at the top of the sediment layer, the sediment layer sound-speed gradient, the half-space sound-speed, and water depth) at 25 Hz and continues by retaining only the high MFP value parameter combinations. Next, frequency is slowly increased while again retaining only the high value combinations. At each stage of the process, only those parameter combinations which give high MFP values at all previous LF predictions are considered (an ever shrinking set). It is important to note that a complete search of each relevant parameter space seems to be necessary not only at multiple (sequential) frequencies but also at multiple ranges in order to eliminate sidelobes, i.e., false solutions. Even so, there are no mathematical guarantees that one final, unique "solution" will be found.
Broadband implementation of coprime linear microphone arrays for direction of arrival estimation.
Bush, Dane; Xiang, Ning
2015-07-01
Coprime arrays represent a form of sparse sensing which can achieve narrow beams using relatively few elements, exceeding the spatial Nyquist sampling limit. The purpose of this paper is to expand on and experimentally validate coprime array theory in an acoustic implementation. Two nested sparse uniform linear subarrays with coprime number of elements ( M and N) each produce grating lobes that overlap with one another completely in just one direction. When the subarray outputs are combined it is possible to retain the shared beam while mostly canceling the other superfluous grating lobes. In this way a small number of microphones ( N+M-1) creates a narrow beam at higher frequencies, comparable to a densely populated uniform linear array of MN microphones. In this work beampatterns are simulated for a range of single frequencies, as well as bands of frequencies. Narrowband experimental beampatterns are shown to correspond with simulated results even at frequencies other than the arrays design frequency. Narrowband side lobe locations are shown to correspond to the theoretical values. Side lobes in the directional pattern are mitigated by increasing bandwidth of analyzed signals. Direction of arrival estimation is also implemented for two simultaneous noise sources in a free field condition.
Energy budget above a high-elevation subalpine forest in complex topography
Turnipseed, A.A.; Blanken, P.D.; Anderson, D.E.; Monson, Russell K.
2002-01-01
Components of the energy budget were measured above a subalpine coniferous forest over two complete annual cycles. Sensible and latent heat fluxes were measured by eddy covariance. Bowen ratios ranged from 0.7 to 2.5 in the summer (June-September) depending upon the availability of soil water, but were considerably higher (???3-6) during winter (December-March). Energy budget closure averaged better than 84% on a half-hourly basis in both seasons with slightly greater closure during the winter months. The energy budget showed a dependence on friction velocity (u*), approaching complete closure at u* values greater than 1 m s-1. The dependence of budget closure on u* explained why energy balance was slightly better in the winter as opposed to summer, since numerous periods of high turbulence occur in winter. It also explained the lower degree of energy closure (???10% less) during easterly upslope flow since these periods were characterized by low wind speeds (U < 4 m s-1) and friction velocities (u* < 0.5 m s-1). Co-spectral analysis suggests a shift of flux density towards higher frequencies under conditions where closure was obtained. It is suggested that low frequency contributions to the flux and advection were responsible for the lack of day-time energy budget closure. These effects were reduced at high friction velocities observed at our site. Our ability to close the energy budget at night was also highly dependent on friction velocity, approaching near closure (???90%) at u* values between 0.7 and 1.1 m s-1. Below this range, the airflow within the canopy becomes decoupled with the flow above. Above this range, insufficient temperature resolution of the sonic anemometer obscured the small temperature fluctuations, rendering measurements intractable. ?? 2002 Elsevier Science B.V. All rights reserved.
Signal Cloaking by Electric Fish
STODDARD, PHILIP K.; MARKHAM, MICHAEL R.
2010-01-01
Electric fish produce weak electric fields to image their world in darkness and to communicate with potential mates and rivals. Eavesdropping by electroreceptive predators exerts selective pressure on electric fish to shift their signals into less-detectable high-frequency spectral ranges. Hypopomid electric fish evolved a signal-cloaking strategy that reduces their detectability by predators in the lab (and thus presumably their risk of predation in the field). These fish produce broad-frequency electric fields close to the body, but the heterogeneous local fields merge over space to cancel the low-frequency spectrum at a distance. Mature males dynamically regulate this cloaking mechanism to enhance or suppress low-frequency energy. The mechanism underlying electric-field cloaking involves electrogenic cells that produce two independent action potentials. In a unique twist, these cells orient sodium and potassium currents in the same direction, potentially boosting their capabilities for current generation. Exploration of such evolutionary inventions could aid the design of biogenerators to power implantable medical devices, an ambition that would benefit from the complete genome sequence of a gymnotiform fish. PMID:20209064
Giandolini, Marlene; Gimenez, Philippe; Temesi, John; Arnal, Pierrick J.; Martin, Vincent; Rupp, Thomas; Morin, Jean-Benoit; Samozino, Pierre; Millet, Guillaume Y.
2016-01-01
Ultramarathon runners are exposed to a high number of impact shocks and to severe neuromuscular fatigue. Runners may manage mechanical stress and muscle fatigue by changing their running kinematics. Our purposes were to study (i) the effects of a 110-km mountain ultramarathon (MUM) on tibial shock acceleration and lower limb kinematics, and (ii) whether kinematic changes are modulated according to the severity of neuromuscular fatigue. Twenty-three runners participated in the study. Pre- and post-MUM, neuromuscular tests were performed to assess knee extensor (KE) and plantar flexor (PF) central and peripheral fatigue, and a treadmill running bouts was completed during which step frequency, peak acceleration, median frequency and impact frequency content were measured from tibial acceleration, as well as foot-to-treadmill, tibia-to-treadmill, and ankle flexion angles at initial contact, and ankle range of motion using video analysis. Large neuromuscular fatigue, including peripheral changes and deficits in voluntary activation, was observed in KE and PF. MVC decrements of ~35% for KE and of ~28% for PF were noted. Among biomechanical variables, step frequency increased by ~2.7% and the ankle range of motion decreased by ~4.1% post-MUM. Runners adopting a non rearfoot strike pre-MUM adopted a less plantarflexed foot strike pattern post-MUM while those adopting a rearfoot strike pre-MUM tended to adopt a less dorsiflexed foot strike pattern post-MUM. Positive correlations were observed between percent changes in peripheral PF fatigue and the ankle range of motion. Peripheral PF fatigue was also significantly correlated to both percent changes in step frequency and the ankle angle at contact. This study suggests that in a fatigued state, ultratrail runners use compensatory/protective adjustments leading to a flatter foot landing and this is done in a fatigue dose-dependent manner. This strategy may aim at minimizing the overall load applied to the musculoskeletal system, including impact shock and muscle stretch. PMID:27031830
CFAVC scheme for high frequency series resonant inverter-fed domestic induction heating system
NASA Astrophysics Data System (ADS)
Nagarajan, Booma; Reddy Sathi, Rama
2016-01-01
This article presents the investigations on the constant frequency asymmetric voltage cancellation control in the AC-AC resonant converter-fed domestic induction heating system. Conventional fixed frequency control techniques used in the high frequency converters lead to non-zero voltage switching operation and reduced output power. The proposed control technique produces higher output power than the conventional fixed-frequency control strategies. In this control technique, zero-voltage-switching operation is maintained during different duty cycle operation for reduction in the switching losses. Complete analysis of the induction heating power supply system with asymmetric voltage cancellation control is discussed in this article. Simulation and experimental study on constant frequency asymmetric voltage cancellation (CFAVC)-controlled full bridge series resonant inverter is performed. Time domain simulation results for the open and closed loop of the system are obtained using MATLAB simulation tool. The simulation results prove the control of voltage and power in a wide range. PID controller-based closed loop control system achieves the voltage regulation of the proposed system for the step change in load. Hardware implementation of the system under CFAVC control is done using the embedded controller. The simulation and experimental results validate the performance of the CFAVC control technique for series resonant-based induction cooking system.
VizieR Online Data Catalog: Planck Catalog of Compact Sources Release 1 (Planck, 2013)
NASA Astrophysics Data System (ADS)
Planck Collaboration
2013-03-01
Planck is a European Space Agency (ESA) mission, with significant contributions from the U.S. National Aeronautics and Space Agency (NASA). It is the third generation of space-based cosmic microwave background experiments, after the Cosmic Background Explorer (COBE) and the Wilkinson Microwave Anisotropy Probe (WMAP). Planck was launched on 14 May 2009 on an Ariane 5 rocket from Kourou, French Guiana. Following a cruise to the Earth-Sun L2 Lagrange point, cooling and in orbit checkout, Planck initiated the First Light Survey on 13 August 2009. Since then, Planck has been continuously measuring the intensity of the sky over a range of frequencies from 30 to 857GHz (wavelengths of 1cm to 350μm) with spatial resolutions ranging from about 33' to 5' respectively. The Low Frequency Instrument (LFI) on Planck provides temperature and polarization information using radiometers which operate between 30 and 70GHz. The High Frequency Instrument (HFI) uses pairs of polarization-sensitive bolometers at each of four frequencies between 100 and 353GHz but does not measure polarization information in the two upper HFI bands at 545 and 857GHz. The lowest frequencies overlap with WMAP, and the highest frequencies extend far into the submillimeter in order to improve separation between Galactic foregrounds and the cosmic microwave background (CMB). By extending to wavelengths longer than those at which the Infrared Astronomical Satellite (IRAS) operated, Planck is providing an unprecedented window into dust emission at far-infrared and submillimeter wavelengths. The PCCS (Planck Catalog of Compact Sources) is the list of sources detected in the first 15 months of Planck "nominal" mission. It consists of nine single-frequency catalogues of compact sources, both Galactic and extragalactic, detected over the entire sky. The PCCS covers the frequency range 30-857 GHz with higher sensitivity (it is 90% complete at 180mJy in the best channel) and better angular resolution than previous all-sky surveys in the microwave band. By construction its reliability is >80% and more than 65% of the sources have been detected at least in two contiguous Planck channels. Many of the Planck PCCS sources can be associated with stars with dust shells, stellar cores, radio galaxies, blazars, infrared luminous galaxies and Galactic interstellar medium features. (12 data files).
Reproduction of mouse-pup ultrasonic vocalizations by nanocrystalline silicon thermoacoustic emitter
NASA Astrophysics Data System (ADS)
Kihara, Takashi; Harada, Toshihiro; Kato, Masahiro; Nakano, Kiyoshi; Murakami, Osamu; Kikusui, Takefumi; Koshida, Nobuyoshi
2006-01-01
As one of the functional properties of ultrasound generator based on efficient thermal transfer at the nanocrystalline silicon (nc-Si) layer surface, its potential as an ultrasonic simulator of vocalization signals is demonstrated by using the acoustic data of mouse-pup calls. The device composed of a surface-heating thin-film electrode, an nc-Si layer, and a single-crystalline silicon (c-Si) wafer, exhibits an almost completely flat frequency response over a wide range without any mechanical surface vibration systems. It is shown that the fabricated emitter can reproduce digitally recorded ultrasonic mouse-pups vocalizations very accurately in terms of the call duration, frequency dispersion, and sound pressure level. The thermoacoustic nc-Si device provides a powerful physical means for the understanding of ultrasonic communication mechanisms in various living animals.
Pseudo-dynamic source characterization accounting for rough-fault effects
NASA Astrophysics Data System (ADS)
Galis, Martin; Thingbaijam, Kiran K. S.; Mai, P. Martin
2016-04-01
Broadband ground-motion simulations, ideally for frequencies up to ~10Hz or higher, are important for earthquake engineering; for example, seismic hazard analysis for critical facilities. An issue with such simulations is realistic generation of radiated wave-field in the desired frequency range. Numerical simulations of dynamic ruptures propagating on rough faults suggest that fault roughness is necessary for realistic high-frequency radiation. However, simulations of dynamic ruptures are too expensive for routine applications. Therefore, simplified synthetic kinematic models are often used. They are usually based on rigorous statistical analysis of rupture models inferred by inversions of seismic and/or geodetic data. However, due to limited resolution of the inversions, these models are valid only for low-frequency range. In addition to the slip, parameters such as rupture-onset time, rise time and source time functions are needed for complete spatiotemporal characterization of the earthquake rupture. But these parameters are poorly resolved in the source inversions. To obtain a physically consistent quantification of these parameters, we simulate and analyze spontaneous dynamic ruptures on rough faults. First, by analyzing the impact of fault roughness on the rupture and seismic radiation, we develop equivalent planar-fault kinematic analogues of the dynamic ruptures. Next, we investigate the spatial interdependencies between the source parameters to allow consistent modeling that emulates the observed behavior of dynamic ruptures capturing the rough-fault effects. Based on these analyses, we formulate a framework for pseudo-dynamic source model, physically consistent with the dynamic ruptures on rough faults.
Renuka Devi, K; Raja, A; Srinivasan, K
2015-05-01
For the first time, the effect of ultrasound in the diagnostic frequency range of 1-10 MHz on the nucleation and growth characteristics of glycine has been explored. The investigation employing the ultrasonic interferometer was carried out at a constant insonation time over a wide range of relative supersaturation from σ=-0.09 to 0.76 in the solution. Ultrasound promotes only α nucleation and completely inhibits both the β and γ nucleation in the system. The propagation of ultrasound assisted mass transport facilitates nucleation even at very low supersaturation levels in the solution. The presence of ultrasound exhibits a profound effect on nucleation and growth characteristics in terms of decrease in induction period, increase in nucleation rate and decrease in crystal size than its absence in the solution. With an increase in the frequency of ultrasound, a further decrease in induction period, increase in nucleation rate and decrease in the size of the crystal is noticed even at the same relative supersaturation levels. The increase in the nucleation rate explains the combined dominating effects of both the ultrasound frequency and the supersaturation in the solution. Analytically, the nucleation parameters of the nucleated polymorph have been deduced at different ultrasonic frequencies based on the classical nucleation theory and correlations with the experimental results have been obtained. Structural affirmation of the nucleated polymorph has been ascertained by powder X-ray diffraction. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pubby, Kunal; Narang, Sukhleen Bindra; Kaur, Prabhjyot; Chawla, S. K.
2017-05-01
Hexaferrite nano-particles of stoichiometric composition {{Sr}}{({{CoZr}})_x}{{F}}{{{e}}_{12 - 2x}}{{{O}}_{19}}, with x = 0.0, 0.2, 0.4, 0.6, 0.8, 1.0 were prepared using sol-gel auto-combustion route owing to its advantages such as low sintering temperature requirement, homogeneity and uniformity of grains. Tartaric acid as a fuel was utilized to complete the chemical reaction. The goal of this study is to analyse the effect of co-substitution of cobalt and zirconium on the electromagnetic and absorption properties of pure {{SrF}}{{{e}}_{12}}{{{O}}_{19}} hexaferrite. The properties were measured on the rectangular pellets of thickness 2.5 mm for K-frequency band using Vector Network Analyzer. The doping of Co-Zr has resulted in increase in real as well as imaginary parts of permittivity. The values of real permittivity lie in the range 3.6-7.0 for all the composition. The real part of permeability remains in range 0.7-1.6 in the studied frequency band for all the samples and shows slightly increasing trend with frequency. The maximum values of dielectric loss tangent peak (3.04) and magnetic loss tangent peak (2.34), among all the prepared compositions, have been observed for composition x = 0.2. Compositions with x = 0.6 and x = 0.0 also have high dielectric and magnetic loss peaks. Dielectric loss peaks are attributed to dielectric resonance and magnetic loss peaks are attributed to natural resonance. Experimentally determined reflection loss results show that all six compositions of prepared series have high values of absorption to propose them as single-layer absorbers in 18-26.5 GHz frequency range. The composition with x = 0.2 has maximum absorption capacity with reflection loss peak of -37.2 dB at 24.3 GHz frequency. The undoped composition also has high absorption peak (-25.46 dB), but -10 dB absorption bandwidth is minimum (2.2 GHz) out of the present series. Maximum absorption bandwidth is obtained for x = 1.0 (4.1 GHz). Other doped compositions also have high absorption bandwidth in range 3.4-3.9 GHz. The results of absorption were related to the dielectric phase angle to conclude that high electro-magnetic losses are dominant factor in deciding absorption properties of ferrites in comparison to impedance matching.
Webber, C J
2001-05-01
This article shows analytically that single-cell learning rules that give rise to oriented and localized receptive fields, when their synaptic weights are randomly and independently initialized according to a plausible assumption of zero prior information, will generate visual codes that are invariant under two-dimensional translations, rotations, and scale magnifications, provided that the statistics of their training images are sufficiently invariant under these transformations. Such codes span different image locations, orientations, and size scales with equal economy. Thus, single-cell rules could account for the spatial scaling property of the cortical simple-cell code. This prediction is tested computationally by training with natural scenes; it is demonstrated that a single-cell learning rule can give rise to simple-cell receptive fields spanning the full range of orientations, image locations, and spatial frequencies (except at the extreme high and low frequencies at which the scale invariance of the statistics of digitally sampled images must ultimately break down, because of the image boundary and the finite pixel resolution). Thus, no constraint on completeness, or any other coupling between cells, is necessary to induce the visual code to span wide ranges of locations, orientations, and size scales. This prediction is made using the theory of spontaneous symmetry breaking, which we have previously shown can also explain the data-driven self-organization of a wide variety of transformation invariances in neurons' responses, such as the translation invariance of complex cell response.
Long-period GPS waveforms. What can GPS bring to Earth seismic velocity models?
NASA Astrophysics Data System (ADS)
Kelevitz, Krisztina; Houlié, Nicolas; Boschi, Lapo; Nissen-Meyer, Tarje; Giardini, Domenico
2014-05-01
It is now commonly admitted that high rate GPS observations can provide reliable surface displacement waveforms (Cervelli, et al., 2001; Langbein, et al., 2006; Houlié, et al., 2006; Houlié et al., 2011). For long-period (T>5s) transients, it was shown that GPS and seismometer (STS-1) displacements are in agreement at least for vertical component (Houlié, et al., Sci. Rep. 2011). We propose here to supplement existing long-period seismic networks with high rate (>= 1Hz) GPS data in order to improve the resolution of global seismic velocity models. GPS measurements are providing a wide range of frequencies, going beyond the range of STS-1 in the low frequency end. Nowadays, almost 10.000 GPS receivers would be able to record data at 1 Hz with 3000+ stations already streaming data in Real-Time (RT). The reasons for this quick expansion are the price of receivers, their low maintenance, and the wide range of activities they can be used for (transport, science, public apps, navigation, etc.). We are presenting work completed on the 1Hz GPS records of the Hokkaido earthquake (25th of September, 2003, Mw=8.3). 3D Waveforms have been computed with an improved, stabilised inversion algorithm in order to constrain the ground motion history. Through the better resolution of inversion of the GPS phase observations, we determine displacement waveforms of frequencies ranging from 0.77 mHz to 330 mHz for a selection of sites. We compare inverted GPS waveforms with STS-1 waveforms and synthetic waveforms computed using 3D global wave propagation with SPECFEM. At co-located sites (STS-1 and GPS located within 10km) the agreement is good for the vertical component between seismic (both real and synthetic) and GPS waveforms.
Papageorgiou, Spyridon N; Antonoglou, Georgios N; Sándor, George K; Eliades, Theodore
2017-01-01
A priori registration of randomized clinical trials is crucial to the transparency and credibility of their findings. Aim of this study was to assess the frequency with which registered and completed randomized trials in orthodontics are published. We searched ClinicalTrials.gov and ISRCTN for registered randomized clinical trials in orthodontics that had been completed up to January 2017 and judged the publication status and date of registered trials using a systematic protocol. Statistical analysis included descriptive statistics, chi-square or Fisher exact tests, and Kaplan-Meier survival estimates. From the 266 orthodontic trials registered up to January 2017, 80 trials had been completed and included in the present study. Among these 80 included trials, the majority (76%) were registered retrospectively, while only 33 (41%) were published at the time. The median time from completion to publication was 20.1 months (interquartile range: 9.1 to 31.6 months), while survival analysis indicated that less than 10% of the trials were published after 5 years from their completion. Finally, 22 (28%) of completed trials remain unpublished even after 5 years from their completion. Publication rates of registered randomized trials in orthodontics remained low, even 5 years after their completion date.
Antonoglou, Georgios N.; Sándor, George K.; Eliades, Theodore
2017-01-01
A priori registration of randomized clinical trials is crucial to the transparency and credibility of their findings. Aim of this study was to assess the frequency with which registered and completed randomized trials in orthodontics are published. We searched ClinicalTrials.gov and ISRCTN for registered randomized clinical trials in orthodontics that had been completed up to January 2017 and judged the publication status and date of registered trials using a systematic protocol. Statistical analysis included descriptive statistics, chi-square or Fisher exact tests, and Kaplan-Meier survival estimates. From the 266 orthodontic trials registered up to January 2017, 80 trials had been completed and included in the present study. Among these 80 included trials, the majority (76%) were registered retrospectively, while only 33 (41%) were published at the time. The median time from completion to publication was 20.1 months (interquartile range: 9.1 to 31.6 months), while survival analysis indicated that less than 10% of the trials were published after 5 years from their completion. Finally, 22 (28%) of completed trials remain unpublished even after 5 years from their completion. Publication rates of registered randomized trials in orthodontics remained low, even 5 years after their completion date. PMID:28777820
Krishnamurthy, Krish
2013-12-01
The intrinsic quantitative nature of NMR is increasingly exploited in areas ranging from complex mixture analysis (as in metabolomics and reaction monitoring) to quality assurance/control. Complex NMR spectra are more common than not, and therefore, extraction of quantitative information generally involves significant prior knowledge and/or operator interaction to characterize resonances of interest. Moreover, in most NMR-based metabolomic experiments, the signals from metabolites are normally present as a mixture of overlapping resonances, making quantification difficult. Time-domain Bayesian approaches have been reported to be better than conventional frequency-domain analysis at identifying subtle changes in signal amplitude. We discuss an approach that exploits Bayesian analysis to achieve a complete reduction to amplitude frequency table (CRAFT) in an automated and time-efficient fashion - thus converting the time-domain FID to a frequency-amplitude table. CRAFT uses a two-step approach to FID analysis. First, the FID is digitally filtered and downsampled to several sub FIDs, and secondly, these sub FIDs are then modeled as sums of decaying sinusoids using the Bayesian approach. CRAFT tables can be used for further data mining of quantitative information using fingerprint chemical shifts of compounds of interest and/or statistical analysis of modulation of chemical quantity in a biological study (metabolomics) or process study (reaction monitoring) or quality assurance/control. The basic principles behind this approach as well as results to evaluate the effectiveness of this approach in mixture analysis are presented. Copyright © 2013 John Wiley & Sons, Ltd.
Three-dimensional near-field MIMO array imaging using range migration techniques.
Zhuge, Xiaodong; Yarovoy, Alexander G
2012-06-01
This paper presents a 3-D near-field imaging algorithm that is formulated for 2-D wideband multiple-input-multiple-output (MIMO) imaging array topology. The proposed MIMO range migration technique performs the image reconstruction procedure in the frequency-wavenumber domain. The algorithm is able to completely compensate the curvature of the wavefront in the near-field through a specifically defined interpolation process and provides extremely high computational efficiency by the application of the fast Fourier transform. The implementation aspects of the algorithm and the sampling criteria of a MIMO aperture are discussed. The image reconstruction performance and computational efficiency of the algorithm are demonstrated both with numerical simulations and measurements using 2-D MIMO arrays. Real-time 3-D near-field imaging can be achieved with a real-aperture array by applying the proposed MIMO range migration techniques.
Accurate electromagnetic modeling of terahertz detectors
NASA Technical Reports Server (NTRS)
Focardi, Paolo; McGrath, William R.
2004-01-01
Twin slot antennas coupled to superconducting devices have been developed over the years as single pixel detectors in the terahertz (THz) frequency range for space-based and astronomy applications. Used either for mixing or direct detection, they have been object of several investigations, and are currently being developed for several missions funded or co-funded by NASA. Although they have shown promising performance in terms of noise and sensitivity, so far they have usually also shown a considerable disagreement in terms of performance between calculations and measurements, especially when considering center frequency and bandwidth. In this paper we present a thorough and accurate electromagnetic model of complete detector and we compare the results of calculations with measurements. Starting from a model of the embedding circuit, the effect of all the other elements in the detector in the coupled power have been analyzed. An extensive variety of measured and calculated data, as presented in this paper, demonstrates the effectiveness and reliability of the electromagnetic model at frequencies between 600 GHz and 2.5THz.
[Intention for self-change across the life span: Focusing on concern about self-change].
Chishima, Yuta
2016-06-01
The purpose of the present study was to examine intention for self-change across the life span using measures of self-esteem, frequency of self-reflection, and concern about self-change. We hypothesized that: (a) Intention for self-change decreases with age because of increased self-esteem, decreased self-reflection and concern about self-change, and (b) Associations among self-esteem, frequency of self-reflection, and intention for self-change are mediated by concern about self-change. Participants (N = 997; age range, 15 to 69 yrs) completed an internet survey. ANOVA results suggested that intention for self-change, concern about self-change, and frequency of self-reflection decreased with age, and that self-esteem-scores increased with age. Simultaneous analysis of multiple age groups showed that for all groups of low self-esteem and frequent self-reflection promoted intention for self-change and that there were significant mediating effects for concern about self-change. Therefore, these findings supported out research hypotheses.
Ultra-broadband THz time-domain spectroscopy of common polymers using THz air photonics.
D'Angelo, Francesco; Mics, Zoltán; Bonn, Mischa; Turchinovich, Dmitry
2014-05-19
Terahertz-range dielectric properties of the common polymers low-density polyethylene (LDPE), cyclic olefin/ethylene copolymer (TOPAS®), polyamide-6 (PA6), and polytetrafluoroethylene (PTFE or Teflon®) are characterized in the ultra-broadband frequency window 2-15 THz, using a THz time-domain spectrometer employing air-photonics for the generation and detection of single-cycle sub-50 fs THz transients. The time domain measurements provide direct access to both the absorption and refractive index spectra. The polymers LDPE and TOPAS® demonstrate negligible absorption and spectrally-flat refractive index across the entire spectroscopy window, revealing the high potential of these polymers for applications in THz photonics such as ultra-broadband polymer-based dielectric mirrors, waveguides, and fibers. Resonant high-frequency polar vibrational modes are observed and assigned in polymers PA6 and PTFE, and their dielectric functions in the complete frequency window 2-15 THz are theoretically reproduced. Our results demonstrate the potential of ultra-broadband air-photonics-based THz time domain spectroscopy as a valuable analytic tool for materials science.
BICMOS power detector for pulsed Rf power amplifiers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bridge, Clayton D.
2016-10-01
A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier's input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. Upon completion of the successive approximation, the detector returns 9-bits representing the amplitude of the RF input signal. Using the pulse waveform from the power amplifier, the detector can dynamically adjust the rate of the binary search operation in order to return the updated amplitude information of the RF input signal at least every 1ms.more » The detector can handle pulse waveform frequencies from 50kHz to 10MHz with duty cycles in the range of 5- 50% and peak power levels of -10 to 10dBm. The signal amplitude measurement can be converted to a peak power measurement accurate to within ±0.6dB of the input RF power.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quinlan, F.; Diddams, S. A.; Ycas, G.
2010-06-15
A 12.5 GHz-spaced optical frequency comb locked to a global positioning system disciplined oscillator for near-infrared (IR) spectrograph calibration is presented. The comb is generated via filtering a 250 MHz-spaced comb. Subsequent nonlinear broadening of the 12.5 GHz comb extends the wavelength range to cover 1380-1820 nm, providing complete coverage over the H-band transmission window of earth's atmosphere. Finite suppression of spurious sidemodes, optical linewidth, and instability of the comb has been examined to estimate potential wavelength biases in spectrograph calibration. Sidemode suppression varies between 20 and 45 dB, and the optical linewidth is {approx}350 kHz at 1550 nm. Themore » comb frequency uncertainty is bounded by {+-}30 kHz (corresponding to a radial velocity of {+-}5 cm/s), limited by the global positioning system disciplined oscillator reference. These results indicate that this comb can readily support radial velocity measurements below 1 m/s in the near IR.« less
Gap detection threshold in the rat before and after auditory cortex ablation.
Syka, J; Rybalko, N; Mazelová, J; Druga, R
2002-10-01
Gap detection threshold (GDT) was measured in adult female pigmented rats (strain Long-Evans) by an operant conditioning technique with food reinforcement, before and after bilateral ablation of the auditory cortex. GDT was dependent on the frequency spectrum and intensity of the continuously present noise in which the gaps were embedded. The mean values of GDT for gaps embedded in white noise or low-frequency noise (upper cutoff frequency 3 kHz) at 70 dB sound pressure level (SPL) were 1.57+/-0.07 ms and 2.9+/-0.34 ms, respectively. Decreasing noise intensity from 80 dB SPL to 20 dB SPL produced a significant increase in GDT. The increase in GDT was relatively small in the range of 80-50 dB SPL for white noise and in the range of 80-60 dB for low-frequency noise. The minimal intensity level of the noise that enabled GDT measurement was 20 dB SPL for white noise and 30 dB SPL for low-frequency noise. Mean GDT values at these intensities were 10.6+/-3.9 ms and 31.3+/-4.2 ms, respectively. Bilateral ablation of the primary auditory cortex (complete destruction of the Te1 and partial destruction of the Te2 and Te3 areas) resulted in an increase in GDT values. The fifth day after surgery, the rats were able to detect gaps in the noise. The values of GDT observed at this time were 4.2+/-1.1 ms for white noise and 7.4+/-3.1 ms for low-frequency noise at 70 dB SPL. During the first month after cortical ablation, recovery of GDT was observed. However, 1 month after cortical ablation GDT still remained slightly higher than in controls (1.8+/-0.18 for white noise, 3.22+/-0.15 for low-frequency noise, P<0.05). A decrease in GDT values during the subsequent months was not observed.
New Wavenumber Calibration Tables From Heterodyne Frequency Measurements
Maki, Arthur G.; Wells, Joseph S.
1992-01-01
This new calibration atlas is based on frequency rather than wavelength calibration techniques for absolute references. Since a limited number of absolute frequency measurements is possible, additional data from alternate methodology are used for difference frequency measurements within each band investigated by the frequency measurements techniques. Data from these complementary techniques include the best Fourier transform measurements available. Included in the text relating to the atlas are a description of the heterodyne frequency measurement techniques and details of the analysis, including the Hamiltonians and least-squares-fitting and calculation. Also included are other relevant considerations such as intensities and lincshape parameters. A 390-entry bibliography which contains all data sources used and a subsequent section on errors conclude the text portion. The primary calibration molecules are the linear triatomics, carbonyl sulfide and nitrous oxide, which cover portions of the infrared spectrum ranging from 488 to 3120 cm−1. Some gaps in the coverage afforded by OCS and N2O are partially covered by NO, CO, and CS2. An additional region from 4000 to 4400 cm−1 is also included. The tabular portion of the atlas is too lengthy to include in an archival journal. Furthermore, different users have different requirements for such an atlas. In an effort to satisfy most users, we have made two different options available. The first is NIST Special Publication 821, which has a spectral map/facing table format. The spectral maps (as well as the facing tables) are calculated from molecular constants derived for the work. A complete list of all of the molecular transitions that went into making the maps is too long (perhaps by a factor of 4 or 5) to include in the facing tables. The second option for those not interested in maps (or perhaps to supplement Special Publication 821) is the complete list (tables-only) which is available in computerized format as NIST Standard Reference Database #39, Wavelength Calibration Tables. PMID:28053441
Comparing Wild 2 Particles to Chondrites and IDPS
NASA Technical Reports Server (NTRS)
Zolensky, Michael; Nakamura-Messenger, Keiko; Rietmeijer, Frans; Leroux, Hugues; Mikouchi, Takashi; Ohsumi, Kazumasa; Simon, Steven; Grossman, Lawrence; Stephan, Thomas; Weisberg, Michael;
2008-01-01
We compare the observed composition ranges of olivine, pyroxene and Fe-Ni sulfides in Wild 2 grains, comparing these with chondritic IDPs and chondrite classes to explore whether these data suggest affinities to known hydrous materials in particular. Wild 2 olivine has an extremely wide composition range, from Fo4-100 with a pronounced frequency peak at Fo99. The composition range displayed by the low-calcium pyroxene is also very extensive, from En52 to En100, with a significant frequency peak centered at En95. These ranges are as broad or broader than those reported for any other extraterrestrial material. Wild 2 Fe-Ni sulfides mainly have compositions close to that of FeS, with less than 2 atom % Ni - to date, only two pentlandite grains have been found among the Wild-grains suggesting that this mineral is not abundant. The complete lack of compositions between FeS and pentlandite (with intermediate solid solution compositions) suggests (but does not require) that FeS and pentlandite condensed as crystalline species, i.e. did not form as amorphous phases, which later became annealed. While we have not yet observed any direct evidence of water-bearing minerals, the presence of Ni-bearing sulfides, and magnesium-dominated olivine and low-Ca pyroxene does not rule out their presence at low abundance. We do conclude that modern major and minor element compositions of chondrite matrix and IDPs are needed.
Vanderhoof, Melanie; Distler, Hayley; Lang, Megan W.; Alexander, Laurie C.
2018-01-01
The dependence of downstream waters on upstream ecosystems necessitates an improved understanding of watershed-scale hydrological interactions including connections between wetlands and streams. An evaluation of such connections is challenging when, (1) accurate and complete datasets of wetland and stream locations are often not available and (2) natural variability in surface-water extent influences the frequency and duration of wetland/stream connectivity. The Upper Choptank River watershed on the Delmarva Peninsula in eastern Maryland and Delaware is dominated by a high density of small, forested wetlands. In this analysis, wetland/stream surface water connections were quantified using multiple wetland and stream datasets, including headwater streams and depressions mapped from a lidar-derived digital elevation model. Surface-water extent was mapped across the watershed for spring 2015 using Landsat-8, Radarsat-2 and Worldview-3 imagery. The frequency of wetland/stream connections increased as a more complete and accurate stream dataset was used and surface-water extent was included, in particular when the spatial resolution of the imagery was finer (i.e., <10 m). Depending on the datasets used, 12–60% of wetlands by count (21–93% of wetlands by area) experienced surface-water interactions with streams during spring 2015. This translated into a range of 50–94% of the watershed contributing direct surface water runoff to streamflow. This finding suggests that our interpretation of the frequency and duration of wetland/stream connections will be influenced not only by the spatial and temporal characteristics of wetlands, streams and potential flowpaths, but also by the completeness, accuracy and resolution of input datasets.
Munhoz, Renato P; Fabiani, Giorgio; Becker, Nilson; Teive, Hélio A G
2009-04-01
Several recent reports have linked the use of dopamine agonists (DAs) to a variety of compulsive behaviors in patients with Parkinson's disease (PD). These inappropriate behaviors may include pathological gambling, compulsive shopping, and hypersexuality. To report the case of a patient with increased range of sexual behavior after use of pramipexole, a DA. A 67-year-old man with a 7-year diagnosis of PD treated with levodopa and pramipexole presented with a dramatic change in sexual behavior after an increase in DA dose. The patient, who historically was a very shy and conservative person, started to present increased frequency of sexual intercourse with his wife, during which he began speaking obscenities with an extreme preference for anal intercourse, preferences never requested before. After pramipexole was withdrawn, complete remission was observed with return to his usual sexual behavior. Hypersexuality and paraphilias are complications not uncommonly found in patients with PD under dopaminergic treatment. Further studies are needed for the understanding of this complex complication, and particularly the most prevalent relationship between pathological hypersexuality and use of DAs.
Migraine exacerbation during Ramadan fasting.
Abu-Salameh, Ibrahim; Plakht, Ygal; Ifergane, Gal
2010-12-01
Fasting for approximately 1 month is an obligatory practice for Muslims during the month of Ramadan. We attempted to evaluate the effect of the Ramadan fasting on the frequency of migraine attacks among observant Muslim migraine sufferers using a cohort cross-over study. Thirty-two observant Muslim migraine sufferers filled a migraine diary during the Ramadan month and the following month (control). Two patients failed to complete the fast because of migraine suffering. During the Ramadan month, the patient expressed 9.4 ± 4.3 migraine days in average (range 3-20) when compared with 3.7 ± 2.1 migraine days in average (range 1-10) during the control month (p < 0.001). This phenomenon was associated with longer duration of migraine, lower frequency of migraine attacks, and migraine with aura. It seemed to be less pronounced in patients experiencing throbbing headaches and in married patients. Previous prophylactic therapy did not dampen this. Physicians treating Muslim migraine patients should discuss potential Ramadan month exacerbation with their patients and provide counseling regarding the prevention of dehydration and caffeine withdrawal. Pharmacological prophylactic treatment should be considered.
Upper Limits on the 21 cm Epoch of Reionization Power Spectrum from One Night with LOFAR
NASA Astrophysics Data System (ADS)
Patil, A. H.; Yatawatta, S.; Koopmans, L. V. E.; de Bruyn, A. G.; Brentjens, M. A.; Zaroubi, S.; Asad, K. M. B.; Hatef, M.; Jelić, V.; Mevius, M.; Offringa, A. R.; Pandey, V. N.; Vedantham, H.; Abdalla, F. B.; Brouw, W. N.; Chapman, E.; Ciardi, B.; Gehlot, B. K.; Ghosh, A.; Harker, G.; Iliev, I. T.; Kakiichi, K.; Majumdar, S.; Mellema, G.; Silva, M. B.; Schaye, J.; Vrbanec, D.; Wijnholds, S. J.
2017-03-01
We present the first limits on the Epoch of Reionization 21 cm H I power spectra, in the redshift range z = 7.9-10.6, using the Low-Frequency Array (LOFAR) High-Band Antenna (HBA). In total, 13.0 hr of data were used from observations centered on the North Celestial Pole. After subtraction of the sky model and the noise bias, we detect a non-zero {{{Δ }}}{{I}}2={(56+/- 13{mK})}2 (1-σ) excess variance and a best 2-σ upper limit of {{{Δ }}}212< {(79.6{mK})}2 at k = 0.053 h cMpc-1 in the range z = 9.6-10.6. The excess variance decreases when optimizing the smoothness of the direction- and frequency-dependent gain calibration, and with increasing the completeness of the sky model. It is likely caused by (I) residual side-lobe noise on calibration baselines, (II) leverage due to nonlinear effects, (III) noise and ionosphere-induced gain errors, or a combination thereof. Further analyses of the excess variance will be discussed in forthcoming publications.
47 CFR 15.202 - Certified operating frequency range.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Certified operating frequency range. 15.202 Section 15.202 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Intentional Radiators § 15.202 Certified operating frequency range. Client devices that operate in a master...
Wireless zoned particulate matter filter regeneration control system
Gonze, Eugene V [Pinckney, MI; Kirby, Kevin W [Calabasas Hills, CA; Phelps, Amanda [Malibu, CA; Gregoire, Daniel J [Thousand Oaks, CA
2011-10-04
An assembly includes a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and multiple zones. An absorbing layer absorbs microwave energy in one of N frequency ranges and is arranged with the upstream end. N is an integer. A frequency selective filter has M frequency selective segments and receives microwave energy in the N frequency ranges. M is an integer. One of the M frequency selective segments permits passage of the microwave energy in one of the N frequency ranges and does not permit passage of microwave energy in the other of the N frequency ranges.
Stachiv, Ivo; Sittner, Petr
2018-01-01
Nanocantilevers have become key components of nanomechanical sensors that exploit changes in their resonant frequencies or static deflection in response to the environment. It is necessary that they can operate at a given, but adjustable, resonant frequency and/or static deflection ranges. Here we propose a new class of nanocantilevers with a significantly tunable spectrum of the resonant frequencies and changeable static deflection utilizing the unique properties of a phase-transforming NiTi film sputtered on the usual nanotechnology cantilever materials. The reversible frequency tuning and the adjustable static deflection are obtained by intentionally changing the Young’s modulus and the interlayer stress of the NiTi film during its phase transformation, while the usual cantilever elastic materials guarantee a high frequency actuation (up to tens of MHz). By incorporating the NiTi phase transformation characteristic into the classical continuum mechanics theory we present theoretical models that account for the nanocantilever frequency shift and variation in static deflection caused by a phase transformation of NiTi film. Due to the practical importance in nanomechanical sensors, we carry out a complete theoretical analysis and evaluate the impact of NiTi film on the cantilever Young’s modulus, static deflection, and the resonant frequencies. Moreover, the importance of proposed NiTi nanocantilever is illustrated on the nanomechanical based mass sensors. Our findings will be of value in the development of advanced nanotechnology sensors with intentionally-changeable physical and mechanical properties. PMID:29462996
Coherent infrared imaging camera (CIRIC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, D.P.; Simpson, M.L.; Bennett, C.A.
1995-07-01
New developments in 2-D, wide-bandwidth HgCdTe (MCT) and GaAs quantum-well infrared photodetectors (QWIP) coupled with Monolithic Microwave Integrated Circuit (MMIC) technology are now making focal plane array coherent infrared (IR) cameras viable. Unlike conventional IR cameras which provide only thermal data about a scene or target, a coherent camera based on optical heterodyne interferometry will also provide spectral and range information. Each pixel of the camera, consisting of a single photo-sensitive heterodyne mixer followed by an intermediate frequency amplifier and illuminated by a separate local oscillator beam, constitutes a complete optical heterodyne receiver. Applications of coherent IR cameras are numerousmore » and include target surveillance, range detection, chemical plume evolution, monitoring stack plume emissions, and wind shear detection.« less
Direct Iterative Nonlinear Inversion by Multi-frequency T-matrix Completion
NASA Astrophysics Data System (ADS)
Jakobsen, M.; Wu, R. S.
2016-12-01
Researchers in the mathematical physics community have recently proposed a conceptually new method for solving nonlinear inverse scattering problems (like FWI) which is inspired by the theory of nonlocality of physical interactions. The conceptually new method, which may be referred to as the T-matrix completion method, is very interesting since it is not based on linearization at any stage. Also, there are no gradient vectors or (inverse) Hessian matrices to calculate. However, the convergence radius of this promising T-matrix completion method is seriously restricted by it's use of single-frequency scattering data only. In this study, we have developed a modified version of the T-matrix completion method which we believe is more suitable for applications to nonlinear inverse scattering problems in (exploration) seismology, because it makes use of multi-frequency data. Essentially, we have simplified the single-frequency T-matrix completion method of Levinson and Markel and combined it with the standard sequential frequency inversion (multi-scale regularization) method. For each frequency, we first estimate the experimental T-matrix by using the Moore-Penrose pseudo inverse concept. Then this experimental T-matrix is used to initiate an iterative procedure for successive estimation of the scattering potential and the T-matrix using the Lippmann-Schwinger for the nonlinear relation between these two quantities. The main physical requirements in the basic iterative cycle is that the T-matrix should be data-compatible and the scattering potential operator should be dominantly local; although a non-local scattering potential operator is allowed in the intermediate iterations. In our simplified T-matrix completion strategy, we ensure that the T-matrix updates are always data compatible simply by adding a suitable correction term in the real space coordinate representation. The use of singular-value decomposition representations are not required in our formulation since we have developed an efficient domain decomposition method. The results of several numerical experiments for the SEG/EAGE salt model illustrate the importance of using multi-frequency data when performing frequency domain full waveform inversion in strongly scattering media via the new concept of T-matrix completion.
Lopez, M.A.; Woodham, W.M.
1983-01-01
Hydrologic data collected on nine small urban watersheds in the Tampa Bay area of west-central Florida and a method for estimating peak discharges in the study area are described. The watersheds have mixed land use and range in size from 0.34 to 3.45 square miles. Watershed soils, land use, and storm-drainage system data are described. Urban development ranged from a sparsely populated area with open-ditch storm sewers and 19% impervious area to a completely sewered watershed with 61% impervious cover. The U.S. Geological Survey natural-basin and urban-watershed models were calibrated for the nine watersheds using 5-minute interval rainfall data from the Tampa, Florida, National Weather Service rain gage to simulate annual peak discharge for the period 1906-52. A log-Pearson Type III frequency analysis of the simulated annual maximum discharge was used to determine the 2-, 5-, 10-, 25-, 50-, and 100-year flood discharges for each watershed. Flood discharges were related in a multiple-linear regression to drainage area, channel slope, detention storage area, and an urban-development factor determined by the extent of curb and gutter street drainage and storm-sewer system. The average standard error for the regional relations ranged from + or - 32 to + or - 42%. (USGS)
1983-05-01
in the presence of fillers or without it. The basic assumption made is that the heat of reaction is proportional to the extent of the reaction...disperse the SillllV* rVdi\\tion ^^9 • .canning machan ^m. ill isolate the frequency range falling on the detector In this manner. the spectrum...the molar orms with only has n absorb ing (nxp) and # by the udied. Of t have a all of the analysis a complete the same There are two basic
More About Lens Antenna For Mobile/Satellite Communication
NASA Technical Reports Server (NTRS)
Rahmat-Samii, Y.; Bodnar, D. G.; Rainer, B. K.
1990-01-01
Report presents additional details of design of proposed phased-array antenna described in "Lens Antenna for Mobile/Satellite Communication" (NPO-16948). Intended to be compact and to lie flat on top of vehicle on ground. Transmits and receives circularly polarized radiation in frequency ranges of 821 to 825 MHz and 860 to 870 MHz. Transmitting and receiving beams electronically steerable to any of 48 evenly spaced directions to provide complete azimuth coverage, and would be fixed, but wide, in elevation, to provide coverage at elevation angles from 20 degrees to 60 degrees.
Johnson, Cynthia R; DeMand, Alexandra; Lecavalier, Luc; Smith, Tristram; Aman, Michael; Foldes, Emily; Scahill, Lawrence
2016-04-01
Sleep disturbances in autism spectrum disorder (ASD) are very common. Psychometrically sound instruments are essential to assess these disturbances. Children's Sleep Habit Questionnaire (CSHQ) is a widely used measure in ASD. The purpose of this study was to explore the psychometric properties of the CSHQ in a sample of children with ASD. Parents/caregivers of 310 children (mean age: 4.7) with ASD completed the CSHQ at study enrollment. Correlations between intelligence quotient (IQ) scores and the original CSHQ scales were calculated. Item endorsement frequencies and percentages were also calculated. A principal component analysis (PCA) was performed, and internal consistency was assessed for the newly extracted components. Correlations between IQ scores and CSHQ subscales and total scores ranged from .015 to .001 suggesting a weak, if any, association. Item endorsement frequencies were high for bedtime resistance items, but lower for parasomnia and sleep-disordered breathing items. A PCA suggested that a five-component solution best fits the data. Internal consistency of the newly extracted five components ranged α = .87-.50. Item endorsement frequencies were highest for bedtime resistance items. A PCA suggested a five-component solution. Three of the five components (Sleep Routine Problems, Insufficient Sleep, and Sleep-onset Association Problems) were types of sleep disturbances commonly reported in ASD, but the other two components (Parasomnia/Sleep-disordered Breathing and Sleep Anxiety) were less clear. Internal consistencies ranged from mediocre to good. Further development of this measure for use in children with ASD is encouraged. Copyright © 2016 Elsevier B.V. All rights reserved.
Distinct Acoustic Features and Glottal Changes Define Two Modes of Singing in Peking Opera.
Li, Gelin; Li, Haiqing; Hou, Qian; Jiang, Zhen
2018-04-06
We aimed to delineate the acoustic characteristics of the Laodan and Qingyi role in Peking Opera and define glottis closure states and mucosal wave changes during singing in the two roles. The range of singing in A4 (440 Hz) pitch in seven female Peking Opera singers was determined using two classic pieces of Peking Opera. Glottal changes during singing were examined by stroboscopic laryngoscope. The fundamental frequency of /i/ in the first 15 seconds of the two pieces and the /i/ pitch range were determined. The relative length of the glottis fissure and the relative maximum mucosal amplitude were calculated. Qingyi had significantly higher mean fundamental frequency than Laodan. The long-term average spectrum showed an obvious formant cluster near 3000 Hz in Laodan versus Qingyi. No formant cluster was observed in singing in the regular mode. Strobe laryngoscopy showed complete glottal closure in Laodan and incomplete glottal closure in Qingyi in the maximal glottis closure phase. The relative length of the glottis fissure of Laodan was significantly lower than that of Qingyi in the singing mode. The relative maximum mucosal amplitude of Qingyi was significantly lower than that of Laodan. The Laodan role and the Qingyi role in Peking Opera sing in a fundamental frequency range compatible with the respective use of da sang (big voice) and xiao sang (small voice). The morphological patterns of glottal changes also indicate that the Laodan role and the Qingyi role sing with da sang and xiao sang, respectively. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Kotter, Dale K [Shelley, ID; Rohrbaugh, David T [Idaho Falls, ID
2010-09-07
A frequency selective surface (FSS) and associated methods for modeling, analyzing and designing the FSS are disclosed. The FSS includes a pattern of conductive material formed on a substrate to form an array of resonance elements. At least one aspect of the frequency selective surface is determined by defining a frequency range including multiple frequency values, determining a frequency dependent permittivity across the frequency range for the substrate, determining a frequency dependent conductivity across the frequency range for the conductive material, and analyzing the frequency selective surface using a method of moments analysis at each of the multiple frequency values for an incident electromagnetic energy impinging on the frequency selective surface. The frequency dependent permittivity and the frequency dependent conductivity are included in the method of moments analysis.
In Vitro Plant Regeneration from Commercial Cultivars of Soybean
Raza, Ghulam; Singh, Mohan B.
2017-01-01
Soybean, a major legume crop, is the source of vegetable oil and protein. There is a need for transgenic approaches to breeding superior soybean varieties to meet future climate challenges. Efficient plant regeneration is a prerequisite for successful application of genetic transformation technology. Soybean cultivars are classified into different maturity groups based on photoperiod requirements. In this study, nine soybean varieties belonging to different maturity group were regenerated successfully from three different explants: half split hypocotyl, complete hypocotyl, and cotyledonary node. All the genotypes and explant types responded by producing adventitious shoots. Shoot induction potential ranged within 60–87%, 50–100%, and 75–100%, and regeneration rate ranged within 4.2–10, 2.7–4.2, and 2.6–10.5 shoots per explant using half split hypocotyl, complete hypocotyl, and cotyledonary explants, respectively, among all the tested genotypes. Bunya variety showed the best regeneration response using half split and complete hypocotyl explants and the PNR791 with cotyledonary node. The regenerated shoots were successfully rooted and acclimatized to glasshouse conditions. This study shows that commercial varieties of soybean are amenable to shoot regeneration with high regeneration frequencies and could be exploited for genetic transformation. Further, our results show no correlation between shoots regeneration capacity with the maturity grouping of the soybean cultivars tested. PMID:28691031
In Vitro Plant Regeneration from Commercial Cultivars of Soybean.
Raza, Ghulam; Singh, Mohan B; Bhalla, Prem L
2017-01-01
Soybean, a major legume crop, is the source of vegetable oil and protein. There is a need for transgenic approaches to breeding superior soybean varieties to meet future climate challenges. Efficient plant regeneration is a prerequisite for successful application of genetic transformation technology. Soybean cultivars are classified into different maturity groups based on photoperiod requirements. In this study, nine soybean varieties belonging to different maturity group were regenerated successfully from three different explants: half split hypocotyl, complete hypocotyl, and cotyledonary node. All the genotypes and explant types responded by producing adventitious shoots. Shoot induction potential ranged within 60-87%, 50-100%, and 75-100%, and regeneration rate ranged within 4.2-10, 2.7-4.2, and 2.6-10.5 shoots per explant using half split hypocotyl, complete hypocotyl, and cotyledonary explants, respectively, among all the tested genotypes. Bunya variety showed the best regeneration response using half split and complete hypocotyl explants and the PNR791 with cotyledonary node. The regenerated shoots were successfully rooted and acclimatized to glasshouse conditions. This study shows that commercial varieties of soybean are amenable to shoot regeneration with high regeneration frequencies and could be exploited for genetic transformation. Further, our results show no correlation between shoots regeneration capacity with the maturity grouping of the soybean cultivars tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, Martin A., E-mail: Martin.Ebert@health.wa.gov.au; School of Physics, University of Western Australia, Perth, Western Australia; Foo, Kerwyn
Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with amore » comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.« less
Mazlyn, Mena M; Nagarajah, Lee H L; Fatimah, A; Norimah, A K; Goh, K L
2013-04-01
Diet and lifestyle modification is commonly used in constipation management. As there is a dearth of studies on this topic in Malaysia, we aim to elucidate the relations between stool patterns, dietary intake and physical activity levels among adults with functional constipation. From a database collected via surveys at public events, a convenience sample of 100 adults diagnosed with Rome II-defined functional constipation was enrolled in this cross-sectional study. After severity assessment using the Chinese Constipation Questionnaire, subjects completed 2-week bowel movement diaries to determine stool frequency, consistency and output. Dietary intake and physical activity levels were assessed twice using three-day 24-hour diet recalls and International Physical Activity Questionnaire, respectively. Ninety subjects who completed the study were included in the analysis. Mean weekly stool frequency was 3.9 +/- 1.9 times, consistency score was 2.6 +/- 0.6 (range 1.0-4.0), output was 11.0 +/- 6.3 balls (40 mm diameter) and severity score was 10.3 +/- 3.3 (range 5.0-22.0). Mean daily dietary intakes were: energy 1,719 +/- 427kcal, dietary fibre 15.0 +/- 4.9g and fluid 2.5 +/- 0.8L. The majority of subjects were physically inactive. Stool frequency and output were positively associated with dietary fibre (r(s) = 0.278, P < 0.01; r(s) = 0.226, P < 0.05) and fluid intake (r(s) = 0.257, P < 0.05; OR = 3.571, 95% CI [1.202-10.609]). Constipation severity was associated with higher physical activity levels (OR = 2.467, 95% CI [1.054-5.777]). Insufficient intake of dietary fibre and fluid are associated with aggravated constipation symptoms. Further studies are necessary to confirm usefulness of dietary intervention in treatment of constipation as dietary factors alone may not influence overall severity and stool consistency, an integral element of constipation.
NASA Astrophysics Data System (ADS)
Lakhin, V. P.; Ilgisonis, V. I.; Smolyakov, A. I.; Sorokina, E. A.; Marusov, N. A.
2018-01-01
The gradient-drift instabilities of partially magnetized plasmas in plasma devices with crossed electric and magnetic fields are investigated in the framework of the two-fluid model with finite electron temperature in an inhomogeneous magnetic field. The finite electron Larmor radius (FLR) effects are also included via the gyroviscosity tensor taking into account the magnetic field gradient. This model correctly describes the electron dynamics for k⊥ρe>1 in the sense of Padé approximants (here, k⊥ and ρe are the wavenumber perpendicular to the magnetic field and the electron Larmor radius, respectively). The local dispersion relation for electrostatic plasma perturbations with the frequency in the range between the ion and electron cyclotron frequencies and propagating strictly perpendicular to the magnetic field is derived. The dispersion relation includes the effects of the equilibrium E ×B electron current, finite ion velocity, electron inertia, electron FLR, magnetic field gradients, and Debye length effects. The necessary and sufficient condition of stability is derived, and the stability boundary is found. It is shown that, in general, the electron inertia and FLR effects stabilize the short-wavelength perturbations. In some cases, such effects completely suppress the high-frequency short-wavelength modes so that only the long-wavelength low-frequency (with respect to the lower-hybrid frequency) modes remain unstable.
NASA Astrophysics Data System (ADS)
Goyal, Rahul; Trivedi, Chirag; Kumar Gandhi, Bhupendra; Cervantes, Michel J.
2017-07-01
Hydraulic turbines are operated over an extended operating range to meet the real time electricity demand. Turbines operated at part load have flow parameters not matching the designed ones. This results in unstable flow conditions in the runner and draft tube developing low frequency and high amplitude pressure pulsations. The unsteady pressure pulsations affect the dynamic stability of the turbine and cause additional fatigue. The work presented in this paper discusses the flow field investigation of a high head model Francis turbine at part load: 50% of the rated load. Numerical simulation of the complete turbine has been performed. Unsteady pressure pulsations in the vaneless space, runner, and draft tube are investigated and validated with available experimental data. Detailed analysis of the rotor stator interaction and draft tube flow field are performed and discussed. The analysis shows the presence of a rotating vortex rope in the draft tube at the frequency of 0.3 times of the runner rotational frequency. The frequency of the vortex rope precession, which causes severe fluctuations and vibrations in the draft tube, is predicted within 3.9% of the experimental measured value. The vortex rope results pressure pulsations propagating in the system whose frequency is also perceive in the runner and upstream the runner.
Experimental observation of a large low-frequency band gap in a polymer waveguide
NASA Astrophysics Data System (ADS)
Miniaci, Marco; Mazzotti, Matteo; Radzieński, Maciej; Kherraz, Nesrine; Kudela, Pawel; Ostachowicz, Wieslaw; Morvan, Bruno; Bosia, Federico; Pugno, Nicola M.
2018-02-01
The quest for large and low frequency band gaps is one of the principal objectives pursued in a number of engineering applications, ranging from noise absorption to vibration control, to seismic wave abatement. For this purpose, a plethora of complex architectures (including multi-phase materials) and multi-physics approaches have been proposed in the past, often involving difficulties in their practical realization. To address this issue, in this work we propose an easy-to-manufacture design able to open large, low frequency complete Lamb band gaps exploiting a suitable arrangement of masses and stiffnesses produced by cavities in a monolithic material. The performance of the designed structure is evaluated by numerical simulations and confirmed by Scanning Laser Doppler Vibrometer (SLDV) measurements on an isotropic polyvinyl chloride plate in which a square ring region of cross-like cavities is fabricated. The full wave field reconstruction clearly confirms the ability of even a limited number of unit cell rows of the proposed design to efficiently attenuate Lamb waves. In addition, numerical simulations show that the structure allows to shift of the central frequency of the BG through geometrical modifications. The design may be of interest for applications in which large BGs at low frequencies are required.
Acoustic noise generation by the DOE/NASA MOD-1 wind turbine
NASA Technical Reports Server (NTRS)
Kelley, N. D.
1981-01-01
The results of a series of measurements taken over the past year of the acoustic emissions from the DOE/NASA MOD-1 Wind Turbine show the maximum acoustic energy is concentrated in the low frequency range, often below 100 Hz. The temporal as well as the frequency characteristics of the turbine sounds have been shown to be important since the MOD-1 is capable of radiating both coherent and incoherent noise. The coherent sounds are usually impulsive and are manifested in an averaged frequency domain plot as large numbers of discrete energy bands extending from the blade passage frequency to beyond 50 Hz on occasion. It is these impulsive sounds which are identified as the principal source of the annoyance to a dozen families living within 3 km of the turbine. The source of the coherent noise appears to be the rapid, unsteady blade loads encountered as the blade passes through the wake of the tower structure. Annoying levels are occasionally reached at nearby homes due to the interaction of the low frequency, high energy peaks in the acoustic impulses and the structural modes of the homes as well as by direct radiation outdoors. The peak levels of these impulses can be enhanced or subdued through complete propagation.
Frequency-dependent sexual selection.
O'Donald, P; Majerus, M E
1988-07-06
Sexual selection by female choice is expected to give rise to a frequency-dependent sexual advantage in favour of preferred male phenotypes: the rarer the preferred phenotypes, the more often they are chosen as mates. This 'rare-male advantage' can maintain a polymorphism when two or more phenotypes are mated preferentially: each phenotype gains an advantage when it is rarer than the others; no preferred phenotype can then be lost from the population. Expression of preference may be complete or partial. In models of complete preference, females with a preference always mate preferentially. Models of partial preference are more realistic: in these models, the probability that a female mates preferentially depends on the frequency with which she encounters the males she prefers. Two different 'encounter models' of partial preference have been derived: the O'Donald model and the Charlesworth model. The encounter models contain the complete preference model as a limiting case. In this paper, the Charlesworth model is generalized to allow for female preference of more than one male phenotype. Levels of frequency dependence can then be compared in the O'Donald and Charlesworth models. The complete preference model and both encounter models are formulated in the same genetical terms of preferences for dominant and recessive male phenotypes. Polymorphic equilibria and conditions for stability are derived for each of the three models. The models are then fitted to data of frequencies of matings observed in experiments with the two-spot ladybird. The complete preference model gives as good a fit as the encounter models to the data of these and other experiments. The O'Donald and Charlesworth encounter models are shown to produce a very similar frequency-dependent relation. Generally, as females become less choosy, they express their preference with more dependence on male frequency, whereas the resulting selection of the males becomes less frequency dependent. More choosy females are more constant in expressing their preference, producing greater frequency dependence in the selection of the males.
Spark Ignition of Monodisperse Fuel Sprays. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Danis, Allen M.; Cernansky, Nicholas P.; Namer, Izak
1987-01-01
A study of spark ignition energy requirements was conducted with a monodisperse spray system allowing independent control of droplet size, equivalent ratio, and fuel type. Minimum ignition energies were measured for n-heptane and methanol sprays characterized at the spark gap in terms of droplet diameter, equivalence ratio (number density) and extent of prevaporization. In addition to sprays, minimum ignition energies were measured for completely prevaporized mixtures of the same fuels over a range of equivalence ratios to provide data at the lower limit of droplet size. Results showed that spray ignition was enhanced with decreasing droplet size and increasing equivalence ratio over the ranges of the parameters studied. By comparing spray and prevaporized ignition results, the existence of an optimum droplet size for ignition was indicated for both fuels. Fuel volatility was seen to be a critical factor in spray ignition. The spray ignition results were analyzed using two different empirical ignition models for quiescent mixtures. Both models accurately predicted the experimental ignition energies for the majority of the spray conditions. Spray ignition was observed to be probabilistic in nature, and ignition was quantified in terms of an ignition frequency for a given spark energy. A model was developed to predict ignition frequencies based on the variation in spark energy and equivalence ratio in the spark gap. The resulting ignition frequency simulations were nearly identical to the experimentally observed values.
Noisy Icebergs: Low Frequency Acoustic Noise Levels Observed off Palmyra Atoll
NASA Astrophysics Data System (ADS)
Matsumoto, H.; Wiggins, S. M.; Sirovic, A.; Tournadre, J.; Oleson, E.; Haxel, J. H.; Dziak, R. P.
2016-12-01
Annually tens of thousands of icebergs from Antarctica drift into the open ocean. In late 2007, two unusually large icebergs, B15a and C19a, entered the Pacific region of the Southern Ocean, and began rapidly disintegrating. Approximately 1.5 years later in April 2009, both icebergs had completely fragmented. An unappreciated aspect of the destructive processes that occur while these large icebergs break apart is the high acoustic source levels that are generated and the contribution of those signals to the ocean soundscape throughout the southern hemisphere. Matsumoto et al. (2014) found evidence of B15a and C19a affecting low-frequency noise levels below 36 Hz at 8°N, 110°W in the eastern equatorial Pacific at a range of 7,500 km. Similar evidence for disintegrating icebergs affecting soundscapes at a similar range was observed in data from 2007-2009 High-frequency Acoustic Recording Package recordings by Scripps Institution of Oceanography near Palmyra atoll in the central equatorial Pacific. Noise levels rose in 2007 as the icebergs entered the Pacific and decreased as the destructive processes declined and the icebergs disintegrated in 2009. This suggests that iceberg sounds are a significant natural noise source in the global ocean, and the area affected by the destructive processes during their decomposition can be as large as the entire southern hemisphere.
NASA Astrophysics Data System (ADS)
López-Caniego, Marcos
2015-08-01
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is observing the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. This experiment will provide valuable information about the polarization properties of synchrotron and anomalous microwave emission at these frequencies. The maps obtained with the multi-frequency instrument (10-20 GHz), in combination with data from other experiments like Planck and the VLA, will be used to clean the diffuse and compact foreground emission at 30 and 40 GHz, the cosmological channels. After three years of effective observations we expect to reach the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r = 0.05. At the moment we have completed the Wide Survey with the multi-frequency instrument, covering 20.000 square degrees of the Northern hemisphere. In addition, we have deep integrations of our main calibrators Taurus A, Cassiopea A, Jupiter and of the Perseus molecular complex region, where we have measured the spectrum of the anomalous microwave emission. We also have observed several regions of interest for our science program where we plan to study the compact and diffuse polarized emission.
NASA Astrophysics Data System (ADS)
Wang, Zhe; Wang, Wen-Qin; Shao, Huaizong
2016-12-01
Different from the phased-array using the same carrier frequency for each transmit element, the frequency diverse array (FDA) uses a small frequency offset across the array elements to produce range-angle-dependent transmit beampattern. FDA radar provides new application capabilities and potentials due to its range-dependent transmit array beampattern, but the FDA using linearly increasing frequency offsets will produce a range and angle coupled transmit beampattern. In order to decouple the range-azimuth beampattern for FDA radar, this paper proposes a uniform linear array (ULA) FDA using Costas-sequence modulated frequency offsets to produce random-like energy distribution in the transmit beampattern and thumbtack transmit-receive beampattern. In doing so, the range and angle of targets can be unambiguously estimated through matched filtering and subspace decomposition algorithms in the receiver signal processor. Moreover, random-like energy distributed beampattern can also be utilized for low probability of intercept (LPI) radar applications. Numerical results show that the proposed scheme outperforms the standard FDA in focusing the transmit energy, especially in the range dimension.
Fiber optic vibration sensor using bifurcated plastic optical fiber
NASA Astrophysics Data System (ADS)
Abdullah, M.; Bidin, N.; Yasin, M.
2016-11-01
An extrinsic fiber optic vibration sensor is demonstrated for a fiber optic displacement sensor based on a bundled multimode fiber to measure a vibration frequency ranging from 100 until 3000 Hz. The front slope has a sensitivity of 0.1938mV/mm and linearity of 99.7% within a measurement range between 0.15-3.00 mm. By placing the diaphragm of the concave load-speaker within the linear range from the probe, the frequency of the vibration can be measured with error percentage of less than 1.54%. The graph of input against output frequency for low, medium and high frequency range show very high linearity up to 99%. Slope for low, medium, and high frequency range are calculated as 1.0026, 0.9934, and 1.0007 respectively. Simplicity, long term stability, low power consumption, wide dynamic and frequency ranges, noise reduction, ruggedness, linearity and light weight make it promising alternative to other well-establish methods for vibration frequency measurement.
Schmuziger, Nicolas; Probst, Rudolf; Smurzynski, Jacek
2004-04-01
The purposes of the study were: (1) To evaluate the intrasession test-retest reliability of pure-tone thresholds measured in the 0.5-16 kHz frequency range for a group of otologically healthy subjects using Sennheiser HDA 200 circumaural and Etymotic Research ER-2 insert earphones and (2) to compare the data with existing criteria of significant threshold shifts related to ototoxicity and noise-induced hearing loss. Auditory thresholds in the frequency range from 0.5 to 6 kHz and in the extended high-frequency range from 8 to 16 kHz were measured in one ear of 138 otologically healthy subjects (77 women, 61 men; mean age, 24.4 yr; range, 12-51 yr) using HDA 200 and ER-2 earphones. For each subject, measurements of thresholds were obtained twice for both transducers during the same test session. For analysis, the extended high-frequency range from 8 to 16 kHz was subdivided into 8 to 12.5 and 14 to 16 kHz ranges. Data for each frequency and frequency range were analyzed separately. There were no significant differences in repeatability for the two transducer types for all frequency ranges. The intrasession variability increased slightly, but significantly, as frequency increased with the greatest amount of variability in the 14 to 16 kHz range. Analyzing each individual frequency, variability was increased particularly at 16 kHz. At each individual frequency and for both transducer types, intrasession test-retest repeatability from 0.5 to 6 kHz and 8 to 16 kHz was within 10 dB for >99% and >94% of measurements, respectively. The results indicated a false-positive rate of <3% in reference to the criteria for cochleotoxicity for both transducer types. In reference to the Occupational Safety and Health Administration Standard Threshold Shift criteria for noise-induced hazards, the results showed a minor false-positive rate of <1% for the HDA 200. Repeatability was similar for both transducer types. Intrasession test-retest repeatability from 0.5 to 12.5 kHz at each individual frequency including the frequency range susceptible to noise-induced hearing loss was excellent for both transducers. Repeatability was slightly, but significantly poorer in the frequency range from 14 to 16 kHz compared with the frequency ranges from 0.5 to 6 or 8 to 12.5 kHz. Measurements in the extended high-frequency range from 8 to 14 kHz, but not up to 16 kHz, may be recommended for monitoring purposes.
Etienne, Gabriel; Dulucq, Stéphanie; Nicolini, Franck-Emmanuel; Morisset, Stéphane; Fort, Marie-Pierre; Schmitt, Anna; Etienne, Madeleine; Hayette, Sandrine; Lippert, Eric; Bureau, Caroline; Tigaud, Isabelle; Adiko, Didier; Marit, Gérald; Reiffers, Josy; Mahon, François-Xavier
2014-01-01
Sustained imatinib treatment in chronic myeloid leukemia patients can result in complete molecular response allowing discontinuation without relapse. We set out to evaluate the frequency of complete molecular response in imatinib de novo chronic phase chronic myeloid leukemia patients, to identify base-line and under-treatment predictive factors of complete molecular response in patients achieving complete cytogenetic response, and to assess if complete molecular response is associated with a better outcome. A random selection of patients on front-line imatinib therapy (n=266) were considered for inclusion. Complete molecular response was confirmed and defined as MR 4.5 with undetectable BCR-ABL transcript levels. Median follow up was 4.43 years (range 0.79–10.8 years). Sixty-five patients (24%) achieved complete molecular response within a median time of 32.7 months. Absence of spleen enlargement at diagnosis, achieving complete cytogenetic response before 12 months of therapy, and major molecular response during the year following complete cytogenetic response was predictive of achieving further complete molecular response. Patients who achieved complete molecular response had better event-free and failure-free survivals than those with complete cytogenetic response irrespective of major molecular response status (95.2% vs. 64.7% vs. 27.7%, P=0.00124; 98.4% vs. 82.3% vs. 56%, P=0.0335), respectively. Overall survival was identical in the 3 groups. In addition to complete cytogenetic response and major molecular response, further deeper molecular response is associated with better event-free and failure-free survivals, and complete molecular response confers the best outcome. PMID:24362549
Development and Reliability Testing of the FEDS System for Classifying Glenohumeral Instability
Kuhn, John E.; Helmer, Tara T.; Dunn, Warren R.; Throckmorton V, Thomas W.
2010-01-01
Background Classification systems for glenohumeral instability (GHI) are opinion based, not validated, and poorly defined. This study is designed to methodologically develop and test a GHI classification system. Methods: Classification System Development A systematic literature review identified 18 systems for classifying GHI. The frequency characteristics used was recorded. Additionally 31 members of the American Shoulder and Elbow Surgeons responded to a survey to identify features important to characterize GHI. Frequency, Etiology, Direction, and Severity (FEDS), were found to be most important. Frequency was defined as solitary (one episode), occasional (2–5x/year), or frequent (>5x/year). Etiology was defined as traumatic or atraumatic. Direction referred to the primary direction of instability (anterior, posterior, or inferior). Severity was defined as either subluxation or dislocation. Methods: Reliability Testing Fifty GHI patients completed a questionnaire at their initial visit. One of six sports medicine fellowship trained physicians completed a similar questionnaire after examining the patient. Patients returned after two weeks and were examined by the original physician and two other physicians. Inter- and intra-rater agreement for the FEDS classification system was calculated. Results Agreement between patients and physicians was lowest for frequency (39%; k=0.130) and highest for direction (82%; k=0.636). Physician intra-rater agreement was 84– 97% for the individual FEDS characteristics (k=0.69 to 0.87)). Physician inter-rater agreement ranged from 82–90% (k=0.44 to 0.76). Conclusions The FEDS system has content validity and is highly reliable for classifying GHI. Physical examination using provocative testing to determine the primary direction of instability produces very high levels of inter- and intra-rater agreement. Level of evidence Level II, Development of Diagnostic Criteria with Consecutive Series of Patients, Diagnosis Study. PMID:21277809
The influence of operational and environmental loads on the process of assessing damages in beams
NASA Astrophysics Data System (ADS)
Furdui, H.; Muntean, F.; Minda, A. A.; Praisach, Z. I.; Gillich, N.
2015-07-01
Damage detection methods based on vibration analysis make use of the modal parameter changes. Natural frequencies are the features that can be acquired most simply and inexpensively. But this parameter is influenced by environmental conditions, e.g. temperature and operational loads as additional masses or axial loads induced by restraint displacements. The effect of these factors is not completely known, but in the numerous actual research it is considered that they affect negatively the damage assessment process. This is justified by the small frequency changes occurring due to damage, which can be masked by the frequency shifts due to external loads. The paper intends to clarify the effect of external loads on the natural frequencies of beams and truss elements, and to show in which manner the damage detection process is affected by these loads. The finite element analysis, performed on diverse structures for a large range of temperature values, has shown that the temperature itself has a very limited effect on the frequency changes. Thus, axial forces resulted due to obstructed displacements can influence more substantially the frequency changes. These facts are demonstrated by experimental and theoretical studies. Finally, we succeed to adapt a prior contrived relation providing the frequency changes due to damage in order to fit the case of known external loads. Whereas a new baseline for damage detection was found, considering the effect of temperature and external loads, this process can be performed without other complication.
Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Ha, C. Y.; Eckberg, D. L.
1994-01-01
1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished by atropine in both tetraplegic and healthy subjects, these rhythms reflect in an important way rhythmic firing of vagal cardiac motoneurones.
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics
NASA Astrophysics Data System (ADS)
Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing
2012-04-01
The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment.
New sample cell configuration for wide-frequency dielectric spectroscopy: DC to radio frequencies.
Nakanishi, Masahiro; Sasaki, Yasutaka; Nozaki, Ryusuke
2010-12-01
A new configuration for the sample cell to be used in broadband dielectric spectroscopy is presented. A coaxial structure with a parallel plate capacitor (outward parallel plate cell: OPPC) has made it possible to extend the frequency range significantly in comparison with the frequency range of the conventional configuration. In the proposed configuration, stray inductance is significantly decreased; consequently, the upper bound of the frequency range is improved by two orders of magnitude from the upper limit of conventional parallel plate capacitor (1 MHz). Furthermore, the value of capacitance is kept high by using a parallel plate configuration. Therefore, the precision of the capacitance measurement in the lower frequency range remains sufficiently high. Finally, OPPC can cover a wide frequency range (100 Hz-1 GHz) with an appropriate admittance measuring apparatus such as an impedance or network analyzer. The OPPC and the conventional dielectric cell are compared by examining the frequency dependence of the complex permittivity for several polar liquids and polymeric films.
Martinell, Jordi; Kowalewski, Michał; Domènech, Rosa
2012-01-01
We report quantitative analyses of drilling predation on the free-living, tube-dwelling serpulid polychaete Ditrupa arietina from the Cope Cabo marine succession (Pliocene, Spain). Tubes of D. arietina are abundant in the sampled units: 9 bulk samples from 5 horizons yielded ∼5925 specimens of D. arietina. Except for fragmentation, tubes were well preserved. Complete specimens ranged from 3.1 to 13.4 mm in length and displayed allometric growth patterns, with larger specimens being relatively slimmer. Drilled Ditrupa tubes were observed in all samples. Drillholes, identified as Oichnus paraboloides, were characterized by circular to elliptical outline (drillhole eccentricity increased with its diameter), parabolic vertical profile, outer diameter larger than inner diameter, penetration of one tube wall only, narrow range of drill-hole sizes, and non-random (anterior) distribution of drillholes. A total of 233 drilled specimens were identified, with drilling frequencies varying across horizons from 2.7% to 21% (3.9% for pooled data). Many tube fragments were broken across a drillhole suggesting that the reported frequencies are conservative and that biologically-facilitated (drill-hole induced) fragmentation hampers fossil preservation of complete serpulid tubes. No failed or repaired holes were observed. Multiple complete drillholes were present (3.9%). Drilled specimens were significantly smaller than undrilled specimens and tube length and drill-hole diameter were weakly correlated. The results suggest that drillholes were produced by a size-selective, site-stereotypic predatory organism of unknown affinity. The qualitative and quantitative patterns reported here are mostly consistent with previous reports on recent and fossil Ditrupa and reveal parallels with drilling patterns documented for scaphopod mollusks, a group that is ecologically and morphologically similar to Ditrupa. Consistent with previous studies, the results suggest that free-dwelling serpulid polychaetes are preyed upon by drilling predators and may provide a viable source of data on biotic interactions in the fossil record. PMID:22496828
Losartan corrects abnormal frequency response of renal vasculature in congestive heart failure.
DiBona, Gerald F; Sawin, Linda L
2003-11-01
In congestive heart failure, renal blood flow is decreased and renal vascular resistance is increased in a setting of increased activity of both the sympathetic nervous and renin-angiotensin systems. The renal vasoconstrictor response to renal nerve stimulation is enhanced. This is associated with an abnormality in the low-pass filter function of the renal vasculature wherein higher frequencies (> or =0.01 Hz) within renal sympathetic nerve activity are not normally attenuated and are passed into the renal blood flow signal. This study tested the hypothesis that excess angiotensin II action mediates the abnormal frequency response characteristics of the renal vasculature in congestive heart failure. In anesthetized rats, the renal vasoconstrictor response to graded frequency renal nerve stimulation was significantly greater in congestive heart failure than in control rats. Losartan attenuated the renal vasoconstrictor response to a significantly greater degree in congestive heart failure than in control rats. In control rats, the frequency response of the renal vasculature was that of a first order (-20 dB/frequency decade) low-pass filter with a corner frequency (-3 dB, 30% attenuation) of 0.002 Hz and 97% attenuation (-30 dB) at > or =0.1 Hz. In congestive heart failure rats, attenuation did not exceed 45% (-5 dB) over the frequency range of 0.001-0.6 Hz. The frequency response of the renal vasculature was not affected by losartan treatment in control rats but was completely restored to normal by losartan treatment in congestive heart failure rats. The enhanced renal vasoconstrictor response to renal nerve stimulation and the associated abnormality in the frequency response characteristics of the renal vasculature seen in congestive heart failure are mediated by the action of angiotensin II on renal angiotensin II AT1 receptors.
Code of Federal Regulations, 2013 CFR
2013-10-01
... intended for communications with space stations or with other Earth stations by means of one or more other...) FAA. Federal Aviation Administration. (21) FCC. Federal Communications Commission. (22) Frequency... (extremely high frequency). The frequency range 30-300 GHz. (2) HF (high frequency). The frequency range 3-30...
Code of Federal Regulations, 2011 CFR
2011-10-01
... intended for communications with space stations or with other Earth stations by means of one or more other...) FAA. Federal Aviation Administration. (21) FCC. Federal Communications Commission. (22) Frequency... (extremely high frequency). The frequency range 30-300 GHz. (2) HF (high frequency). The frequency range 3-30...
Code of Federal Regulations, 2014 CFR
2014-10-01
... intended for communications with space stations or with other Earth stations by means of one or more other...) FAA. Federal Aviation Administration. (21) FCC. Federal Communications Commission. (22) Frequency... (extremely high frequency). The frequency range 30-300 GHz. (2) HF (high frequency). The frequency range 3-30...
Code of Federal Regulations, 2012 CFR
2012-10-01
... intended for communications with space stations or with other Earth stations by means of one or more other...) FAA. Federal Aviation Administration. (21) FCC. Federal Communications Commission. (22) Frequency... (extremely high frequency). The frequency range 30-300 GHz. (2) HF (high frequency). The frequency range 3-30...
Predicting Achievable Fundamental Frequency Ranges in Vocalization Across Species
Titze, Ingo; Riede, Tobias; Mau, Ted
2016-01-01
Vocal folds are used as sound sources in various species, but it is unknown how vocal fold morphologies are optimized for different acoustic objectives. Here we identify two main variables affecting range of vocal fold vibration frequency, namely vocal fold elongation and tissue fiber stress. A simple vibrating string model is used to predict fundamental frequency ranges across species of different vocal fold sizes. While average fundamental frequency is predominantly determined by vocal fold length (larynx size), range of fundamental frequency is facilitated by (1) laryngeal muscles that control elongation and by (2) nonlinearity in tissue fiber tension. One adaptation that would increase fundamental frequency range is greater freedom in joint rotation or gliding of two cartilages (thyroid and cricoid), so that vocal fold length change is maximized. Alternatively, tissue layers can develop to bear a disproportionate fiber tension (i.e., a ligament with high density collagen fibers), increasing the fundamental frequency range and thereby vocal versatility. The range of fundamental frequency across species is thus not simply one-dimensional, but can be conceptualized as the dependent variable in a multi-dimensional morphospace. In humans, this could allow for variations that could be clinically important for voice therapy and vocal fold repair. Alternative solutions could also have importance in vocal training for singing and other highly-skilled vocalizations. PMID:27309543
Introduction to power-frequency electric and magnetic fields.
Kaune, W T
1993-01-01
This paper introduces the reader to electric and magnetic fields, particularly those fields produced by electric power systems and other sources using frequencies in the power-frequency range. Electric fields are produced by electric charges; a magnetic field also is produced if these charges are in motion. Electric fields exert forces on other charges; if in motion, these charges will experience magnetic forces. Power-frequency electric and magnetic fields induce electric currents in conducting bodies such as living organisms. The current density vector is used to describe the distribution of current within a body. The surface of the human body is an excellent shield for power-frequency electric fields, but power-frequency magnetic fields penetrate without significant attenuation; the electric fields induced inside the body by either exposure are comparable in magnitude. Electric fields induced inside a human by most environmental electric and magnetic fields appear to be small in magnitude compared to levels naturally occurring in living tissues. Detection of such fields thus would seem to require the existence of unknown biological mechanisms. Complete characterization of a power-frequency field requires measurement of the magnitudes and electrical phases of the fundamental and harmonic amplitudes of its three vector components. Most available instrumentation measures only a small subset, or some weighted average, of these quantities. Hand-held survey meters have been used widely to measure power-frequency electric and magnetic fields. Automated data-acquisition systems have come into use more recently to make electric- and magnetic-field recordings, covering periods of hours to days, in residences and other environments.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8206045
Operational fitness of box truss antennas in response to dynamic slewing
NASA Technical Reports Server (NTRS)
Bachtell, E. E.; Bettadapur, S. S.; Schartel, W. A.; Karanian, L. A.
1985-01-01
A parametric study was performed to define slewing capability of large satellites along with associated system changes or subsystem weight and complexity impacts. The satellite configuration and structural arrangement from the Earth Observation Spacecraft (EOS) study was used as the baseline spacecraft. Varying slew rates, settling times, damping, maneuver frequencies, and attitude hold times provided the data required to establish applicability to a wide range of potential missions. The key elements of the study are: (1) determine the dynamic transient response of the antenna system; (2) calculate the system errors produced by the dynamic response; (3) determine if the antenna has exceeded operational requirements at completion of the slew, and if so; (4) determine when the antenna has settled to the operational requirements. The slew event is not considered complete until the antenna is within operational limits.
NASA Technical Reports Server (NTRS)
Ulaby, F. T. (Principal Investigator); Wilson, E. A.
1984-01-01
A semi-empirical model for microwave backscatter from vegetation was developed and a complete set of canope attenuation measurements as a function of frequency, incidence angle and polarization was acquired. The semi-empirical model was tested on corn and sorghum data over the 8 to 35 GHz range. The model generally provided an excellent fit to the data as measured by the correlation and rms error between observed and predicted data. The model also predicted reasonable values of canopy attenuation. The attenuation data was acquired over the 1.6 to 10.2 GHz range for the linear polarizations at approximately 20 deg and 50 deg incidence angles for wheat and soybeans. An attenuation model is proposed which provides reasonable agreement with the measured data.
Validation of a Deterministic Vibroacoustic Response Prediction Model
NASA Technical Reports Server (NTRS)
Caimi, Raoul E.; Margasahayam, Ravi
1997-01-01
This report documents the recently completed effort involving validation of a deterministic theory for the random vibration problem of predicting the response of launch pad structures in the low-frequency range (0 to 50 hertz). Use of the Statistical Energy Analysis (SEA) methods is not suitable in this range. Measurements of launch-induced acoustic loads and subsequent structural response were made on a cantilever beam structure placed in close proximity (200 feet) to the launch pad. Innovative ways of characterizing random, nonstationary, non-Gaussian acoustics are used for the development of a structure's excitation model. Extremely good correlation was obtained between analytically computed responses and those measured on the cantilever beam. Additional tests are recommended to bound the problem to account for variations in launch trajectory and inclination.
NASA Astrophysics Data System (ADS)
Essama, Bedel Giscard Onana; Atangana, Jacques; Frederick, Biya Motto; Mokhtari, Bouchra; Eddeqaqi, Noureddine Cherkaoui; Kofane, Timoleon Crepin
2014-09-01
We investigate the behavior of the electromagnetic wave that propagates in a metamaterial for negative index regime. Second-order dispersion and cubic-quintic nonlinearities are taken into account. The behavior obtained for negative index regime is compared to that observed for absorption regime. The collective coordinates technique is used to characterize the light pulse intensity profile at some frequency ranges. Five frequency ranges have been pointed out. The perfect combination of second-order dispersion and cubic nonlinearity leads to a robust soliton at each frequency range for negative index regime. The soliton peak power progressively decreases for absorption regime. Further, this peak power also decreases with frequency. We show that absorption regime can induce rogue wave trains generation at a specific frequency range. However, this rogue wave trains generation is maintained when the quintic nonlinearity comes into play for negative index regime and amplified for absorption regime at a specific frequency range. It clearly appears that rogue wave behavior strongly depends on the frequency and the regime considered. Furthermore, the stability conditions of the electromagnetic wave have also been discussed at frequency ranges considered for both negative index and absorption regimes.
Essama, Bedel Giscard Onana; Atangana, Jacques; Frederick, Biya Motto; Mokhtari, Bouchra; Eddeqaqi, Noureddine Cherkaoui; Kofane, Timoleon Crepin
2014-09-01
We investigate the behavior of the electromagnetic wave that propagates in a metamaterial for negative index regime. Second-order dispersion and cubic-quintic nonlinearities are taken into account. The behavior obtained for negative index regime is compared to that observed for absorption regime. The collective coordinates technique is used to characterize the light pulse intensity profile at some frequency ranges. Five frequency ranges have been pointed out. The perfect combination of second-order dispersion and cubic nonlinearity leads to a robust soliton at each frequency range for negative index regime. The soliton peak power progressively decreases for absorption regime. Further, this peak power also decreases with frequency. We show that absorption regime can induce rogue wave trains generation at a specific frequency range. However, this rogue wave trains generation is maintained when the quintic nonlinearity comes into play for negative index regime and amplified for absorption regime at a specific frequency range. It clearly appears that rogue wave behavior strongly depends on the frequency and the regime considered. Furthermore, the stability conditions of the electromagnetic wave have also been discussed at frequency ranges considered for both negative index and absorption regimes.
Method for ambiguity resolution in range-Doppler measurements
NASA Technical Reports Server (NTRS)
Heymsfield, Gerald M. (Inventor); Miller, Lee S. (Inventor)
1994-01-01
A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.
Rodriguez, Carly A.; Smith, Emily R.; Villamor, Eduardo; Zavaleta, Nelly; Respicio-Torres, Graciela; Contreras, Carmen; Perea, Sara; Jimenez, Judith; Tintaya, Karen; Lecca, Leonid; Murray, Megan B.; Franke, Molly F.
2017-01-01
Tools to assess intake among children in Latin America are limited. We developed and assessed the reproducibility and validity of a semi-quantitative food frequency questionnaire (FFQ) administered to children, adolescents, and their caregivers in Lima, Peru. We conducted 24-h diet recalls (DRs) and focus groups to develop a locally-tailored FFQ prototype for children aged 0–14 years. To validate the FFQ, we administered two FFQs and three DRs to children and/or their caregivers (N = 120) over six months. We examined FFQ reproducibility by quartile agreement and Pearson correlation coefficients, and validity by quartile agreement and correlation with DRs. For reproducibility, quartile agreement ranged from 60–77% with correlations highest for vitamins A and C (0.31). Age-adjusted correlations for the mean DR and the second-administered FFQ were highest in the 0–7 age group, in which the majority of caregivers completed the FFQ on behalf of the child (total fat; 0.67) and in the 8–14 age group, in which both the child and caregiver completed the FFQ together (calcium, niacin; 0.54); correlations were <0.10 for most nutrients in the 8–14 age group in which the caregiver completed the FFQ on the child’s behalf. The FFQ was reproducible and the first developed and validated to assess various nutrients in children and adolescents in Peru. PMID:29036893
A new instrument designedfor frequency-domain sounding in the depth range 0-10 m uses short coil spacings of 5 m or less and a frequency range of 300 kHz to 30 MHz. In this frequency range, both conduction currents (controlled by electrical conductibity) and displacement currents...
Improving frequencies range measurement of vibration sensor based on Fiber Bragg Grating (FBG)
NASA Astrophysics Data System (ADS)
Qomaruddin; Setiono, A.; Afandi, M. I.
2017-04-01
This research aimed to develop a vibration sensor based on Fiber Bragg Grating (FBG). The design was mainly done by attaching FBG at the cantilever. The free-end of the cantilever was tied to a vibration source in order to increase the measurement range of vibration frequencies. The results indicated that the developed sensor was capable of detecting wide range of frequencies (i.e. 10 - 1700 Hz). The results also showed both good stability and repeatability. The measured frequency range was 566 times greater than the range obtained from the previous works.
Reflected wave manipulation by inhomogeneous impedance via varying-depth acoustic liners
NASA Astrophysics Data System (ADS)
Guo, Jingwen; Zhang, Xin; Fang, Yi; Fattah, Ryu
2018-05-01
Acoustic liners, consisting of a perforated panel affixed to a honeycomb core with a rigid back plate, are widely used for noise attenuation purpose. In this study, by exploiting inhomogeneous impedance properties, we report an experimental and numerical study on a liner-type acoustic metasurface, which possesses the functionality of both reflected wave manipulation and sound energy attenuation simultaneously. To realize the inhomogeneous acoustic impedance, an acoustic metasurface constructed by varying-depth acoustic liners is designed and fabricated. The reflected sound pressure fields induced by the metasurface are obtained in both experiments and simulations. A complete characterization of this metasurface is performed, including the effects of depth gradient, incident angle, and incident frequency. Anomalous reflection, apparent negative reflection, and conversion from an incident wave to a surface wave with strong energy dissipation are achieved by the structure. Moreover, our proposed structure can overcome the single frequency performance limitation that exists in conventional metasurfaces and performs well in a broadband frequency range. The proposed acoustic metasurface offers flexibility in controlling the direction of sound wave propagation with energy dissipation property and holds promise for various applications of noise reduction.
Corrosion monitoring using high-frequency guided waves
NASA Astrophysics Data System (ADS)
Fromme, P.
2016-04-01
Corrosion can develop due to adverse environmental conditions during the life cycle of a range of industrial structures, e.g., offshore oil platforms, ships, and desalination plants. Generalized corrosion leading to wall thickness loss can cause the reduction of the strength and thus degradation of the structural integrity. The monitoring of corrosion damage in difficult to access areas can be achieved using high frequency guided waves propagating along the structure from accessible areas. Using standard ultrasonic wedge transducers with single sided access to the structure, guided wave modes were selectively generated that penetrate through the complete thickness of the structure. The wave propagation and interference of the different guided wave modes depends on the thickness of the structure. Laboratory experiments were conducted for wall thickness reduction due to milling of the steel structure. From the measured signal changes due to the wave mode interference the reduced wall thickness was monitored. Good agreement with theoretical predictions was achieved. The high frequency guided waves have the potential for corrosion damage monitoring at critical and difficult to access locations from a stand-off distance.
Corrosion monitoring using high-frequency guided ultrasonic waves
NASA Astrophysics Data System (ADS)
Fromme, Paul
2014-02-01
Corrosion develops due to adverse environmental conditions during the life cycle of a range of industrial structures, e.g., offshore oil platforms, ships, and desalination plants. Both pitting corrosion and generalized corrosion leading to wall thickness loss can cause the degradation of the structural integrity. The nondestructive detection and monitoring of corrosion damage in difficult to access areas can be achieved using high frequency guided waves propagating along the structure from accessible areas. Using standard ultrasonic transducers with single sided access to the structure, guided wave modes were generated that penetrate through the complete thickness of the structure. The wave propagation and interference of the different guided wave modes depends on the thickness of the structure. Laboratory experiments were conducted and the wall thickness reduced by consecutive milling of the steel structure. Further measurements were conducted using accelerated corrosion in a salt water bath and the damage severity monitored. From the measured signal change due to the wave mode interference the wall thickness reduction was monitored. The high frequency guided waves have the potential for corrosion damage monitoring at critical and difficult to access locations from a stand-off distance.
Transmission and reflection of terahertz plasmons in two-dimensional plasmonic devices
Sydoruk, Oleksiy; Choonee, Kaushal; Dyer, Gregory Conrad
2015-03-10
We found that plasmons in two-dimensional semiconductor devices will be reflected by discontinuities, notably, junctions between gated and non-gated electron channels. The transmitted and reflected plasmons can form spatially- and frequency-varying signals, and their understanding is important for the design of terahertz detectors, oscillators, and plasmonic crystals. Using mode decomposition, we studied terahertz plasmons incident on a junction between a gated and a nongated channel. The plasmon reflection and transmission coefficients were found numerically and analytically and studied between 0.3 and 1 THz for a range of electron densities. At higher frequencies, we could describe the plasmons by a simplifiedmore » model of channels in homogeneous dielectrics, for which the analytical approximations were accurate. At low frequencies, however, the full geometry and mode spectrum had to be taken into account. Moreover, the results agreed with simulations by the finite-element method. As a result, mode decomposition thus proved to be a powerful method for plasmonic devices, combining the rigor of complete solutions of Maxwell's equations with the convenience of analytical expressions.« less
The role of age, gender, mood states and exercise frequency on exercise dependence.
Costa, Sebastiano; Hausenblas, Heather A; Oliva, Patrizia; Cuzzocrea, Francesca; Larcan, Rosalba
2013-12-01
The purpose of our study was to explore the prevalence, and the role of mood, exercise frequency, age, and gender differences of exercise dependence. Regular exercisers (N = 409) completed a socio-demographic questionnaire, the Exercise Dependence Scale, and the Profile of Mood States. For data analyses, the participants were stratified for sex and age (age ranges = young adults: 18-24 years, adults: 25-44 years, and middle-aged adults: 45-64 years). We found that: (a) 4.4% of the participants were classified as at-risk for exercise dependence; (b) the men and the two younger groups (i.e., young adults and adults) had higher exercise dependence scores; and (c) age, gender, exercise frequency, and mood state were related to exercise dependence. Our results support previous research on the prevalence of exercise dependence and reveal that adulthood may be the critical age for developing exercise dependence. These findings have practical implication for identifying individuals at-risk for exercise dependence symptoms, and may aid in targeting and guiding the implementation of prevention program for adults.
Experimental measurements of hydrodynamic stiffness matrices for a centrifugal pump impeller
NASA Technical Reports Server (NTRS)
Chamieh, D. S.; Acosta, A. J.; Brennen, C. E.; Caughey, T. K.; Franz, R.
1982-01-01
The objective of the Rotor Force Test Facility at the California Institute of Technology is to artificially orbit the center of rotation of an impeller enclosed within a volute over a range of frequencies from zero to synchronous and to measure the resulting forces on the impeller. Preliminary data from the first stage experiments in which the shaft is orbited at low frequency is reported. Steady volute forces along with stiffness matrices due to the change in position of the rotor center are measured. Static pressure taps around the volute are used to obtain volute pressure distributions for various fixed positions of the impeller center and for various flow rates. Static pressure forces are calculated from these pressure distributions allowing a more complete analysis of the components of the impeller forces. Comparison is made with various existing theoretical and experimental results.
The Wilkinson Microwave Anisotropy Probe (WMAP) Source Catalog
NASA Technical Reports Server (NTRS)
Wright, E.L.; Chen, X.; Odegard, N.; Bennett, C.L.; Hill, R.S.; Hinshaw, G.; Jarosik, N.; Komatsu, E.; Nolta, M.R.; Page, L.;
2008-01-01
We present the list of point sources found in the WMAP 5-year maps. The technique used in the first-year and three-year analysis now finds 390 point sources, and the five-year source catalog is complete for regions of the sky away from the galactic plane to a 2 Jy limit, with SNR greater than 4.7 in all bands in the least covered parts of the sky. The noise at high frequencies is still mainly radiometer noise, but at low frequencies the CMB anisotropy is the largest uncertainty. A separate search of CMB-free V-W maps finds 99 sources of which all but one can be identified with known radio sources. The sources seen by WMAP are not strongly polarized. Many of the WMAP sources show significant variability from year to year, with more than a 2:l range between the minimum and maximum fluxes.
NASA Astrophysics Data System (ADS)
Romero-García, V.; Vasseur, J. O.; Garcia-Raffi, L. M.; Hladky-Hennion, A. C.
2012-02-01
The complex band structures calculated using the extended plane wave expansion (EPWE) reveal the presence of evanescent modes in periodic systems, never predicted by the classical \\omega(\\vec {k}) methods, providing novel interpretations of several phenomena as well as a complete picture of the system. In this work, we theoretically and experimentally observe that in the ranges of frequencies where a deaf band is traditionally predicted, an evanescent mode with excitable symmetry appears, changing drastically the interpretation of the transmission properties. On the other hand, the simplicity of the sonic crystals in which only the longitudinal polarization can be excited is used to interpret, without loss of generality, the level repulsion between symmetric and antisymmetric bands in sonic crystals as the presence of an evanescent mode connecting both repelled bands. These evanescent modes, obtained using EPWE, explain both the attenuation produced in this range of frequencies and the transfer of symmetry from one band to the other in good agreement with both experimental results and multiple scattering predictions. Thus, the evanescent properties of the periodic system have been revealed to be necessary for the design of new acoustic and electromagnetic applications based on periodicity.
Plyler, Patrick N; Reber, Monika Bertges; Kovach, Amanda; Galloway, Elisabeth; Humphrey, Elizabeth
2013-02-01
Multichannel wide dynamic range compression (WDRC) and ChannelFree processing have similar goals yet differ significantly in terms of signal processing. Multichannel WDRC devices divide the input signal into separate frequency bands; a separate level is determined within each frequency band; and compression in each band is based on the level within each band. ChannelFree processing detects the wideband level, and gain adjustments are based on the wideband signal level and adjusted up to 20,000 times per second. Although both signal processing strategies are currently available in hearing aids, it is unclear if differences in these signal processing strategies affect the performance and/or preference of the end user. The purpose of the research was to determine the effects of multichannel wide dynamic range compression and ChannelFree processing on performance and/or preference of listeners using open-canal hearing instruments. An experimental study in which subjects were exposed to a repeated measures design was utilized. Fourteen adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Participants completed two 5 wk trial periods for each signal processing strategy. Probe microphone, behavioral and subjective measures were conducted unaided and aided at the end of each trial period. Behavioral and subjective results for both signal processing strategies were significantly better than unaided results; however, behavioral and subjective results were not significantly different between the signal processing strategies. Multichannel WDRC and ChannelFree processing are both effective signal processing strategies that provide significant benefit for hearing instrument users. Overall preference between the strategies may be related to the degree of hearing loss of the user, high-frequency in-situ levels, and/or acceptance of background noise. American Academy of Audiology.
Extraordinary absorption of sound in porous lamella-crystals.
Christensen, J; Romero-García, V; Picó, R; Cebrecos, A; de Abajo, F J García; Mortensen, N A; Willatzen, M; Sánchez-Morcillo, V J
2014-04-14
We present the design of a structured material supporting complete absorption of sound with a broadband response and functional for any direction of incident radiation. The structure which is fabricated out of porous lamellas is arranged into a low-density crystal and backed by a reflecting support. Experimental measurements show that strong all-angle sound absorption with almost zero reflectance takes place for a frequency range exceeding two octaves. We demonstrate that lowering the crystal filling fraction increases the wave interaction time and is responsible for the enhancement of intrinsic material dissipation, making the system more absorptive with less material.
Extraordinary absorption of sound in porous lamella-crystals
Christensen, J.; Romero-García, V.; Picó, R.; Cebrecos, A.; de Abajo, F. J. García; Mortensen, N. A.; Willatzen, M.; Sánchez-Morcillo, V. J.
2014-01-01
We present the design of a structured material supporting complete absorption of sound with a broadband response and functional for any direction of incident radiation. The structure which is fabricated out of porous lamellas is arranged into a low-density crystal and backed by a reflecting support. Experimental measurements show that strong all-angle sound absorption with almost zero reflectance takes place for a frequency range exceeding two octaves. We demonstrate that lowering the crystal filling fraction increases the wave interaction time and is responsible for the enhancement of intrinsic material dissipation, making the system more absorptive with less material. PMID:24728322
Effect of push frequency on the economy of wheelchair racers.
Goosey, V L; Campbell, I G; Fowler, N E
2000-01-01
The aim of the study was to examine the effect of varying push frequency on pushing economy (oxygen uptake at a given speed). Eight male wheelchair racers completed a series of exercise bouts on a wheelchair ergometer (Bromking Turbo Trainer, Bromakin, UK) at 6.58 m x s(-1). Initially, subjects self-selected their freely chosen push frequency (FCF); this was followed by 4 random trials pushing at 60, 80, 120, and 140% of this FCF. Steady state VO2 was determined using Douglas bags, and heart rate was recorded by telemetry. After each condition, a small capillary blood sample was obtained and analyzed for blood lactate concentration (BLa) and a rating of perceived exertion (RPE) was recorded. At 6.58 m x s(-1) oxygen uptake, RPE, and gross mechanical efficiency were nonlinearly related to push frequency. Analysis of variance showed a significant effect (P < 0.05) of cycle frequency on VO2. VO2 was 11% higher at the 140% FCF compared with the 100% FCF condition. Changes in push frequency had little effect on HR although BLa increased linearly and was higher at the 140% FCF condition compared with 60% FCF (P < 0.05). A two-dimensional sagittal plane video analysis showed large interindividual differences in propulsion style. Both cycle time and the propulsion phase (%) decreased as the push frequency increased. The start angle and end angle of hand contact were similar for conditions, whereas the range of trunk motion decreased with push frequency (P < 0.05). The results of this study showed that the push frequency had an effect on pushing economy, and that the athletes' FCF was the most economical.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stein, Peter J.; Edson, Patrick L.
2013-12-20
This project saw the completion of the design and development of a second generation, high frequency (90-120 kHz) Subsurface-Threat Detection Sonar Network (SDSN). The system was deployed, operated, and tested in Cobscook Bay, Maine near the site the Ocean Renewable Power Company TidGen™ power unit. This effort resulted in a very successful demonstration of the SDSN detection, tracking, localization, and classification capabilities in a high current, MHK environment as measured by results from the detection and tracking trials in Cobscook Bay. The new high frequency node, designed to operate outside the hearing range of a subset of marine mammals, wasmore » shown to detect and track objects of marine mammal-like target strength to ranges of approximately 500 meters. This performance range results in the SDSN system tracking objects for a significant duration - on the order of minutes - even in a tidal flow of 5-7 knots, potentially allowing time for MHK system or operator decision-making if marine mammals are present. Having demonstrated detection and tracking of synthetic targets with target strengths similar to some marine mammals, the primary hurdle to eventual automated monitoring is a dataset of actual marine mammal kinematic behavior and modifying the tracking algorithms and parameters which are currently tuned to human diver kinematics and classification.« less
NASA Technical Reports Server (NTRS)
Manning, Robert M.
2008-01-01
Long-range, over-the-horizon (transhorizon) radio wave propagation is considered for the case of the Moon. In the event that relay satellites are not available or otherwise unwarranted for use, transhorizon communication provides for a contingency or backup option for non line-of-sight lunar surface exploration scenarios. Two potential low-frequency propagation mechanisms characteristic of the lunar landscape are the lunar regolith and the photoelectron induced plasma exosphere enveloping the Moon. Although it was hoped that the regolith would provide for a spherical waveguide which could support a trapped surface wave phenomena, it is found that, in most cases, the regolith is deleterious to long range radio wave propagation. However, the presence of the plasma of the lunar exosphere supports wave propagation and, in fact, surpasses the attenuation of the regolith. Given the models of the regolith and exosphere adopted here, it is recommended that a frequency of 1 MHz be considered for low rate data transmission along the lunar surface. It is also recommended that further research be done to capture the descriptive physics of the regolith and the exospheric plasma so that a more complete model can be obtained. This comprehensive theoretical study is based entirely on first principles and the mathematical techniques needed are developed as required; it is self-contained and should not require the use of outside resources for its understanding.
The singer's voice range profile: female professional opera soloists.
Lamarche, Anick; Ternström, Sten; Pabon, Peter
2010-07-01
This work concerns the collection of 30 voice range profiles (VRPs) of female operatic voice. We address the questions: Is there a need for a singer's protocol in VRP acquisition? Are physiological measurements sufficient or should the measurement of performance capabilities also be included? Can we address the female singing voice in general or is there a case for categorizing voices when studying phonetographic data? Subjects performed a series of structured tasks involving both standard speech voice protocols and additional singing tasks. Singers also completed an extensive questionnaire. Physiological VRPs differ from performance VRPs. Two new VRP metrics, the voice area above a defined level threshold and the dynamic range independent from the fundamental frequency (F(0)), were found to be useful in the analysis of singer VRPs. Task design had no effect on performance VRP outcomes. Voice category differences were mainly attributable to phonation frequency-based information. Results support the clinical importance of addressing the vocal instrument as it is used in performance. Equally important is the elaboration of a protocol suitable for the singing voice. The given context and instructions can be more important than task design for performance VRPs. Yet, for physiological VRP recordings, task design remains critical. Both types of VRPs are suggested for a singer's voice evaluation. Copyright (c) 2010 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sachse, C.; Brockmoeller, J.; Bauer, S.
Cytochrome P450 2D6 (CYP2D6) metabolizes many important drugs. CYP2D6 activity ranges from complete deficiency to ultrafast metabolism, depending on at least 16 different known alleles. Their frequencies were determined in 589 unrelated German volunteers and correlated with enzyme activity measured by phenotyping with dextromethorphan or debrisoquine. For genotyping, nested PCR-RFLP tests from a PCR amplificate of the entire CYP2D6 gene were developed. The frequency of the CYP2D6*1 allele coding for extensive metabolizer (EM) phenotype was .364. The alleles coding for slightly (CYP2D6*2) or moderately (*9 and *10) reduced activity (intermediate metabolizer phenotype [IM]) showed frequencies of .324, .018, and .015,more » respectively. By use of novel PCR tests for discrimination, CYP2D6 gene duplication alleles were found with frequencies of.005 (*1 x 2), .013 (* 2 x 2), and .001 (*4 x 2). Frequencies of alleles with complete deficiency (poor metabolizer phenotype [PM]) were .207 (*4), .020 (*3 and *5), .009 (*6), and .001 (*7, *15, and *16). The defective CYP2D6 alleles *8, *11, *12, *13, and *14 were not found. All 41 PMs (7.0%) in this sample were explained by five mutations detected by four PCR-RFLP tests, which may suffice, together with the gene duplication test, for clinical prediction of CYP2D6 capacity. Three novel variants of known CYP2D6 alleles were discovered: *1C (T{sub 1957}C), *2B (additional C{sub 2558}T), and *4E (additional C{sub 2938}T). Analysis of variance showed significant differences in enzymatic activity measured by the dextromethorphan metabolic ratio (MR) between carriers of EN/PM (mean MR = .006) and IM/PM (mean MR = .014) alleles and between carriers of one (mean MR = .009) and two (mean MR = .003) functional alleles. The results of this study provide a solid basis for prediction of CYP2D6 capacity, as required in drug research and routine drug treatment. 35 refs., 4 figs., 5 tabs.« less
A spectroscopic survey of Orion KL between 41.5 and 50 GHz.
Rizzo, J R; Tercero, B; Cernicharo, J
2017-09-01
The nearby massive star-forming region Orion KL is one of the richest molecular reservoirs known in our Galaxy. The region hosts newly formed protostars, and the strong interaction between their radiation and their outflows with the environment results in a series of complex chemical processes leading to a high diversity of interstellar tracers. The region is therefore one of the most frequently observed sources, and the site where many molecular species have been discovered for the first time. With the availability of powerful wideband backends, it is nowadays possible to complete spectral surveys in the entire mm-range to obtain a spectroscopically unbiased chemical picture of the region. In this paper we present a sensitive spectral survey of Orion KL, made with one of the 34 m antennas of the Madrid Deep Space Communications Complex in Robledo de Chavela, Spain. The spectral range surveyed is from 41.5 to 50 GHz, with a frequency spacing of 180 kHz (equivalent to ≈ 1.2 km s -1 , depending on the exact frequency). The rms achieved ranges from 8 to 12 mK. The spectrum is dominated by the J = 1 → 0 SiO maser lines and by radio recombination lines (RRLs), which were detected up to Δ n = 11. Above a 3 σ level, we identified 66 RRLs and 161 molecular lines corresponding to 39 isotopologues from 20 molecules; a total of 18 lines remain unidentified, two of them above a 5 σ level. Results of radiative modelling of the detected molecular lines (excluding masers) are presented. At this frequency range, this is the most sensitive survey and also the one with the widest band. Although some complex molecules like CH 3 CH 2 CN and CH 2 CHCN arise from the hot core, most of the detected molecules originate from the low temperature components in Orion KL.
Safety of famciclovir in patients with herpes zoster and genital herpes.
Saltzman, R; Jurewicz, R; Boon, R
1994-01-01
Safety reporting from individual ongoing and completed clinical studies has demonstrated that famciclovir, the well-absorbed oral form of the antiherpesvirus agent penciclovir, has been well tolerated by more than 3,000 individuals worldwide. An integrated safety evaluation has been performed and includes over 1,600 patients from 11 completed, randomized, double-blind clinical trials and 2 open trials. The famciclovir population consisted of 816 herpes zoster patients (four trials), 409 patients with acute genital herpesvirus infections (seven trials), and 382 patients from two genital herpes suppression studies. Overall, the famciclovir-treated patient population was 57.7% female and ranged in age from 15 to 102 years (mean, 42.6 years), with 31.2% aged 50 years or more and 15.7% aged 65 years or more. The mean duration of exposure to famciclovir was 28.8 days (5.8 days excluding suppression studies). The total daily doses ranged from 125 mg to 2.25 g. The most common adverse experiences reported as related to study medication (famciclovir and placebo) were headache, nausea, and diarrhea. The frequencies of adverse experiences and laboratory abnormalities (hematology, clinical chemistry, and urinalysis parameters) were similar in both famciclovir and placebo recipients. Thus, safety data from the analysis of 13 completed clinical studies demonstrate that famciclovir is tolerated well by patients with either herpes zoster or genital and has a safety profile comparable to that of placebo. PMID:7840587
Schinkel-Ivy, Alison; Singer, Jonathan C.; Inness, Elizabeth L.; Mansfield, Avril
2016-01-01
Objective To determine whether quiet standing measures at specific frequency levels (representative of reactive control) differed between individuals with stroke based on their ability to recover balance (failed or successful responses to external perturbations). Methods Individuals with stroke completed a clinical assessment, including 30 s of quiet standing and lean-and-release postural perturbations, at admission to in-patient rehabilitation. Quiet standing centre of pressure (COP) signals were calculated and discrete wavelet decomposition was performed. Net COP amplitude, between-limb synchronization, and ratios of individual-limb COP were determined for each frequency level of interest, and for the non-decomposed signal (all frequency levels). Outcome measures were compared between individuals who exhibited failed and successful responses during a) unconstrained and b) encouraged-use lean-and-release trials. Results Individuals with failed responses during the unconstrained lean-and-release trials displayed greater net COP amplitude than those with successful responses, specifically within a frequency range of 0.40–3.20 Hz. Conclusions Reduced ability to recover balance among individuals with stroke may be reflected in impaired reactive control of quiet standing. Significance These results provide insight into the mechanism by which reactive control of quiet standing is impaired in individuals with stroke, and may inform assessment and rehabilitation strategies for post-stroke reactive balance control. PMID:27178866
Physical Demands Study - Focus Groups
2015-10-26
a 76-91 lb Fighting Load Standard: • Sprint 100 meters (in 3 to 5 second increments) as quickly as possible. Terrain: Various Is it reasonable to...Frequency Range Frequency Range Frequency Range Frequency Range 1 : Foot March 25.7± 21.5 5-50 200.0 ± 173.0 100- 400 16.4 ± 64.6 3-33 57.6 ± 64.6 15-200 2...Grenades Standard: • Throw at least one Hand Grenade 30 meters Is it reasonable to expect a Soldier in your MOS to meet this standard? Task 3
Theoretical analysis of HVAC duct hanger systems
NASA Technical Reports Server (NTRS)
Miller, R. D.
1987-01-01
Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalid, Usman; McGough, Camilla; Hackett, Claire
Purpose: Simple scales with greater sensitivity than Radiation Therapy Oncology Group (RTOG) grading to detect acute gastrointestinal toxicity during pelvic radiotherapy, could be clinically useful. Methods and Materials: Do questionnaires used in benign gastrointestinal diseases detect toxicity in patients undergoing radiotherapy? The patient-completed Inflammatory Bowel Disease (IBDQ) and Vaizey Incontinence questionnaires were compared prospectively at baseline and at Week 5 to physician-completed RTOG grading. Results: A total of 107 patients, median age 63 years, were recruited. After 5 weeks of treatment, patients with gynecologic and gastrointestinal cancer were more symptomatic than urologic patients (p 0.012; p = 0.014). Overall, 94%more » had altered bowel habits, 80% loose stool, 74% frequency, 65% difficult gas, 60% pain, >48% distress, 44% tenesmus, >40% restrictions in daily activity, 39% urgency, 37% fecal incontinence, and 40% required antidiarrheal medication. The median RTOG score was 1 (range, 0-2), median IBDQ score 204.5 (range, 74-224), and median Vaizey score 5 (range, 0-20). Chemotherapy preceding radiotherapy increased fecal incontinence (p 0.002). RTOG scores stabilized after 3 weeks, IBDQ scores peaked at Week 4, and Vaizey scores worsened throughout treatment. IBDQ and Vaizey scores distinguished between groups with different RTOG scores. Conclusion: The IBDQ and Vaizey questionnaires are reliable and sensitive, offering greater insight into the severity and range of symptoms compared with RTOG grading.« less
On the Use of Experimental Methods to Improve Confidence in Educed Impedance
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.
2011-01-01
Results from impedance eduction methods developed by NASA Langley Research Center are used throughout the acoustic liner community. In spite of recent enhancements, occasional anomalies persist with these methods, generally at frequencies where the liner produces minimal attenuation. This investigation demonstrates an experimental approach to educe impedance with increased confidence over a desired frequency range, by combining results from successive tests with different cavity depths. A series of tests is conducted with three wire-mesh facesheets, for which the results should be weakly dependent on source sound pressure level and mean grazing flow speed. First, a raylometer is used to measure the DC flow resistance of each facesheet. These facesheets are then mounted onto a frame and a normal incidence tube is used to determine their respective acoustic impedance spectra. A comparison of the acoustic resistance component with the DC flow resistance for each facesheet is used to validate the measurement process. Next, each facesheet is successively mounted onto three frames with different cavity depths, and a grazing flow impedance tube is used to educe their respective acoustic impedance spectra with and without mean flow. The no-flow results are compared with those measured in the normal incidence tube to validate the impedance eduction method. Since the anti-resonance frequency varies with cavity depth, each sample provides robust results over a different frequency range. Hence, a combination of results can be used to determine the facesheet acoustic resistance. When combined with the acoustic reactance, observed to be weakly dependent on the source sound pressure level and grazing flow Mach number, the acoustic impedance can be educed with increased confidence. Representative results of these tests are discussed, and the complete database is available in electronic format upon request.
Hill, Andrew P; Appleton, Paul R
2011-04-01
Perfectionism has been identified as an antecedent of athlete burnout. However, to date, researchers examining the relationship between perfectionism and athlete burnout have measured perfectionism at a trait level. The work of Flett and colleagues (Flett, Hewitt, Blankstein, & Gray, 1998) suggests that perfectionism can also be assessed in terms of individual differences in the frequency with which they experience perfectionistic cognitions. The aims of this study were to: (1)examine the relationship between the frequency of perfectionistic cognitions and symptoms of athlete burnout; and (2)determine whether the frequency of perfectionistic cognitions account for additional unique variance in symptoms of athlete burnout above the variance accounted for by self-oriented and socially prescribed dimensions of perfectionism. Two-hundred and two male rugby players (mean age 18.8 years, s = 2.9, range 16-24) were recruited from youth teams of professional and semi-professional rugby union clubs in the UK. Participants completed measures of trait perfectionism, frequency of perfectionistic cognitions, and symptoms of athlete burnout. The frequency of perfectionistic cognitions was positively related to all symptoms of athlete burnout and explained 3-4% unique variance in symptoms of athlete burnout after controlling for self-oriented and socially prescribed dimensions of perfectionism. Findings suggest that the frequency with which perfectionistic cognitions are experienced may also be an antecedent of athlete burnout. Perfectionistic cognitions should, therefore, be considered in both future models of the relationship between perfectionism and athlete burnout, as well as interventions aimed at reducing perfectionism fuelled burnout.
An Almost Complete Radio Survey of Magnetic Cataclysmic Variables
NASA Astrophysics Data System (ADS)
Dieck, Christopher A.; Everett Barrett, Paul; Beasley, Anthony J.; Pal Singh, Kulinder; Boboltz, David A.; Godon, Patrick; Mason, Paul A.
2016-01-01
This poster presents the results of a radio survey using the Jansky Very Large Array (JVLA) of 129 Magnetic Cataclysmic Variables (MCVs) north of declination -35 deg. 103 hours of observations were performed during the JVLA observing sessions 2013B and 2015A, when the array was mostly in its highest spatial-resolution configurations (i.e., A and B). Most targets were observed twice for 2-5 minutes at each of three frequencies (C, X, and K-bands), although a few targets were also observed at a fourth frequency (Q-band). 22 of the 129 MCVS were detected at one or more frequencies. Of these 22 detections, 15 are new. This number nearly triples the number of MCVs that are known radio sources. Most detections are at the C and X-band frequencies, although three sources were detected at the K-band frequency. One of the K-band frequency detections is the known rapidly-rotating radio source AE Aqr, while the other two are the polars, AI Tri and ST LMi. Of the 22 detected sources, two-thirds are polars (15) and all are believed to be nearby (<200 pc). Except for a few stronger sources, most detections are in the range of 100-200 µJy, which at a distance of 150 pc corresponds roughly to a luminosity of 2x1024 erg/s at the X-band frequency. The results of this survey are encouraging in that more MCVs are likely to be detected as the time on-source increases, since the flux from MCVs is highly variable.
Clinicians' recognition and management of emotions during difficult healthcare conversations.
Martin, Elliott B; Mazzola, Natalia M; Brandano, Jessica; Luff, Donna; Zurakowski, David; Meyer, Elaine C
2015-10-01
To examine the most commonly reported emotions encountered among healthcare practitioners when holding difficult conversations, including frequency and impact on care delivery. Interprofessional learners from a range of experience levels and specialties completed self-report questionnaires prior to simulation-based communication workshops. Clinicians were asked to describe up to three emotions they experienced when having difficult healthcare conversations; subsequent questions used Likert-scales to measure frequency of each emotion, and whether care was affected. 152 participants completed questionnaires, including physicians, nurses, and psychosocial professionals. Most commonly reported emotions were anxiety, sadness, empathy, frustration, and insecurity. There were significant differences in how clinicians perceived these different emotions affecting care. Empathy and anxiety were emotions perceived to influence care more than sadness, frustration, and insecurity. Most clinicians, regardless of clinical experience and discipline, find their emotional state influences the quality of their care delivery. Most clinicians rate themselves as somewhat to quite capable of recognizing and managing their emotions, acknowledging significant room to grow. Further education designed to increase clinicians' recognition of, reflection on, and management of emotion would likely prove helpful in improving their ability to navigate difficult healthcare conversations. Interventions aimed at anxiety management are particularly needed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
The National Cancer Institute diet history questionnaire: validation of pyramid food servings.
Millen, Amy E; Midthune, Douglas; Thompson, Frances E; Kipnis, Victor; Subar, Amy F
2006-02-01
The performance of the National Cancer Institute's food frequency questionnaire, the Diet History Questionnaire (DHQ), in estimating servings of 30 US Department of Agriculture Food Guide Pyramid food groups was evaluated in the Eating at America's Table Study (1997-1998), a nationally representative sample of men and women aged 20-79 years. Participants who completed four nonconsecutive, telephone-administered 24-hour dietary recalls (n = 1,301) were mailed a DHQ; 965 respondents completed both the 24-hour dietary recalls and the DHQ. The US Department of Agriculture's Pyramid Servings Database was used to estimate intakes of pyramid servings for both diet assessment tools. The correlation (rho) between DHQ-reported intake and true intake and the attenuation factor (lambda) were estimated using a measurement error model with repeat 24-hour dietary recalls as the reference instrument. Correlations for energy-adjusted pyramid servings of foods ranged from 0.43 (other starchy vegetables) to 0.84 (milk) among women and from 0.42 (eggs) to 0.80 (total dairy food) among men. The mean rho and lambda after energy adjustment were 0.62 and 0.60 for women and 0.63 and 0.66 for men, respectively. This food frequency questionnaire validation study of foods measured in pyramid servings allowed for a measure of food intake consistent with national dietary guidance.
Ketogenic diet in adolescents and adults with epilepsy.
Nei, Maromi; Ngo, Ly; Sirven, Joseph I; Sperling, Michael R
2014-06-01
The ketogenic diet is an alternative treatment for patients with refractory epilepsy. Most studies to date report dietary response in children. There are limited data evaluating the efficacy of the ketogenic diet in adults. This is a report of the long-term outcome in a largely adult population of patients treated with the ketogenic diet for epilepsy. Twenty-nine adult and adolescent patients (mean age 32 years, range 11-51) were initiated on the ketogenic diet and followed until diet discontinuation. Clinical response and adverse effects were noted during the duration of the diet. Fifty-two percent of patients had a significant reduction in seizure frequency on the ketogenic diet, including 45% with ≥50% reduction in seizure frequency. Thirty-one percent had no improvement, seven percent were unable to successfully initiate the diet, and 10% had a >50% increase in seizure frequency. The diet was continued for a mean of 9 months (range 0.13-35 months), with five patients completing ≥23 months. There was a trend toward better response and better tolerability/longer duration in patients with symptomatic generalized epilepsy. The diet was generally well-tolerated, but undesired weight loss and constipation were the most frequent adverse effects. The ketogenic diet can be used safely in the adult and adolescent population, with a response rate similar to those seen in children. Patient with symptomatic generalized epilepsy may be particularly good candidates for this type of dietary treatment. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Concert halls with strong lateral reflections enhance musical dynamics.
Pätynen, Jukka; Tervo, Sakari; Robinson, Philip W; Lokki, Tapio
2014-03-25
One of the most thrilling cultural experiences is to hear live symphony-orchestra music build up from a whispering passage to a monumental fortissimo. The impact of such a crescendo has been thought to depend only on the musicians' skill, but here we show that interactions between the concert-hall acoustics and listeners' hearing also play a major role in musical dynamics. These interactions contribute to the shoebox-type concert hall's established success, but little prior research has been devoted to dynamic expression in this three-part transmission chain as a complete system. More forceful orchestral playing disproportionately excites high frequency harmonics more than those near the note's fundamental. This effect results in not only more sound energy, but also a different tone color. The concert hall transmits this sound, and the room geometry defines from which directions acoustic reflections arrive at the listener. Binaural directional hearing emphasizes high frequencies more when sound arrives from the sides of the head rather than from the median plane. Simultaneously, these same frequencies are emphasized by higher orchestral-playing dynamics. When the room geometry provides reflections from these directions, the perceived dynamic range is enhanced. Current room-acoustic evaluation methods assume linear behavior and thus neglect this effect. The hypothesis presented here is that the auditory excitation by reflections is emphasized with an orchestra forte most in concert halls with strong lateral reflections. The enhanced dynamic range provides an explanation for the success of rectangularly shaped concert-hall geometry.
NASA Astrophysics Data System (ADS)
Zhang, Xiyang; Gao, Shiqiao; Li, Dongguang; Jin, Lei; Wu, Qinghe; Liu, Feng
2018-04-01
At present, frequency up-converted piezoelectric energy harvesters are disadvantaged by their narrow range of operating frequencies and low efficiency at ultralow-frequency excitation. To address these shortcomings, we propose herein an impact-driven frequency up-converted piezoelectric energy harvester composed of two driving beams and a generating beam. We find experimentally that the proposed device offers efficient energy output over an ultrawide-frequency-range and performs very well in the ultralow-frequency excitation. A maximum peak power of 29.3 mW is achieved under 0.5g acceleration at the excitation frequency of 12.7 Hz. The performance of the energy harvester can be adjusted and optimized by adjusting the spacing between the driving and generating beams. The results show that the proposed harvester has the potential to power miniaturized portable devices and wireless sensor nodes.
Discrete-time model reduction in limited frequency ranges
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Juang, Jer-Nan; Longman, Richard W.
1991-01-01
A mathematical formulation for model reduction of discrete time systems such that the reduced order model represents the system in a particular frequency range is discussed. The algorithm transforms the full order system into balanced coordinates using frequency weighted discrete controllability and observability grammians. In this form a criterion is derived to guide truncation of states based on their contribution to the frequency range of interest. Minimization of the criterion is accomplished without need for numerical optimization. Balancing requires the computation of discrete frequency weighted grammians. Close form solutions for the computation of frequency weighted grammians are developed. Numerical examples are discussed to demonstrate the algorithm.
Widely tunable laser frequency offset lock with 30 GHz range and 5 THz offset.
Biesheuvel, J; Noom, D W E; Salumbides, E J; Sheridan, K T; Ubachs, W; Koelemeij, J C J
2013-06-17
We demonstrate a simple and versatile method to greatly extend the tuning range of optical frequency shifting devices, such as acousto-optic modulators (AOMs). We use this method to stabilize the frequency of a tunable narrow-band continuous-wave (CW) laser to a transmission maximum of an external Fabry-Perot interferometer (FPI) with a tunable frequency offset. This is achieved through a servo loop which contains an in-loop AOM for simple radiofrequency (RF) tuning of the optical frequency over the full 30 GHz mode-hop-free tuning range of the CW laser. By stabilizing the length of the FPI to a stabilized helium-neon (HeNe) laser (at 5 THz offset from the tunable laser) we simultaneously transfer the ~ 1 MHz absolute frequency stability of the HeNe laser to the entire 30 GHz range of the tunable laser. Thus, our method allows simple, wide-range, fast and reproducible optical frequency tuning and absolute optical frequency measurements through RF electronics, which is here demonstrated by repeatedly recording a 27-GHz-wide molecular iodine spectrum at scan rates up to 500 MHz/s. General technical aspects that determine the performance of the method are discussed in detail.
NASA Astrophysics Data System (ADS)
Boisvert, J.-S.; Stafford, L.; Naudé, N.; Margot, J.; Massines, F.
2018-03-01
Diffuse dielectric barrier discharges are generated over a very wide range of frequencies. According to the targeted frequency, the glow, Townsend-like, hybrid, Ω and RF-α modes are sustained. In this paper, the electrical characterization of the discharge cell together with an electrical model are used to estimate the electron density from current and voltage measurements for excitation frequencies ranging from 50 kHz to 15 MHz. The electron density is found to vary from 1014 to 1017 m-3 over this frequency range. In addition, a collisional-radiative model coupled with optical emission spectroscopy is used to evaluate the electron temperature (assuming Maxwellian electron energy distribution function) in the same conditions. The time and space-averaged electron temperature is found to be about 0.3 eV in both the low-frequency and high-frequency ranges. However, in the medium-frequency range, it reaches almost twice this value as the discharge is in the hybrid mode. The hybrid mode is similar to the atmospheric-pressure glow discharge usually observed in helium DBDs at low frequency with the major difference being that the plasma is continuously sustained and is characterized by a higher power density.
Impact of wind on ambient noise recorded by the "13 BB star" seismic array in northern Poland
NASA Astrophysics Data System (ADS)
Lepore, Simone; Markowicz, Krzysztof; Grad, Marek
2016-04-01
Seismic interferometry and beam forming techniques were applied to ambient noise recorded during January 2014 at the "13 BB star" array, composed of thirteen seismic stations located in northern Poland, with the aim of evaluating the azimuth of noise sources and the velocities of surface waves. After normalizing the raw recordings in time and frequency domain, the spectral characteristics of the ambient noise were studied to choose a frequency band suitable for the waves' retrieval. To get the velocity of surface waves by seismic interferometry, the crosscorrelation between all station pairs was analysed for the vertical and horizontal components in the 0.05-0.1 Hz, 0.1-1 Hz and 1 10 Hz frequency bands. For each pair, the crosscorrelation was applied to one hour recordings extracted from the ambient noise. The obtained traces were calculated for a complete day, and then summed together: the daily results were stacked for the whole January 2014. In the lowest frequency range, most of the energy is located around the 3.0 km/s line, meaning that the surface waves coming from the uppermost mantle will be retrieved. The intermediate frequency range shows most of the energy between the 2.0 km/s and 1.5 km/s lines: consequently, surface waves originating from the crust will be retrieved. In the highest frequency range, the surface waves are barely visible on the crosscorrelation traces, implying that the associated energy is strongly attenuated. The azimuth variation associated to the noise field was evaluated by means of the beam forming method, using the data from the whole array for all the three components. To that, the beam power was estimated in a small range of frequencies every day for the whole month. For each day, one hour long results of beam forming applications were stacked together. To avoid aliasing and near field effects, the minimum frequency was set at 0.05 Hz and the maximum to 0.1 Hz. In this frequency band, the amplitude maximum was sought corresponding to the best fit between phase slowness and back azimuth. The azimuth was mainly associated to the angle of the highest peak on the vertical component; however, if the related energy was not large enough, the angle of the main noise source on the horizontal component was employed. In some cases, the azimuth of the secondary peak was taken into account, if its energy was strong enough. The results were related to the daily mean wind speed around Europe recorded during the same month. A significant correlation between the daily average level of ambient noise and the mean wind speed was found. The main source of the ambient noise was located in the Atlantic Ocean and in the North Sea: some weaker sources, however, were identified as the Barents, Baltic, Mediterranean, and Black Seas. National Science Centre Poland provided financial support for this work by NCN grant DEC 2011/02/A/ST10/00284.
Frequency weighting for vibration-induced white finger compatible with exposure-response models.
Brammer, Anthony J; Pitts, Paul M
2012-01-01
An analysis has been performed to derive a frequency weighting for the development of vibration-induced white finger (VWF). It employs a model to compare health risks for pairs of population groups that are selected to have similar health outcomes from operating power tools or machines with markedly different acceleration spectra (rock drills, chain saws, pavement breakers and motorcycles). The model defines the Relative Risk, RR(f(trial)), which is constructed from the ratio of daily exposures and includes a trial frequency weighting that is applied to the acceleration spectra. The trial frequency weighting consists of a frequency-independent primary frequency range, and subordinate frequency ranges in which the response to vibration diminishes, with cut-off frequencies that are changed to influence the magnitude of RR(f(trial)). The frequency weighting so derived when RR(f(trial)) = 1 is similar to those obtained by other methods (W(hf), W(hT)). It consists of a frequency independent range from about 25 Hz to 500 Hz (-3 dB frequencies), with an amplitude cut-off rate of 12 dB/octave below 25 Hz and above 500 Hz. The range is compatible with studies of vasoconstriction in persons with VWF. The results provide further evidence that the ISO frequency weighting may be inappropriate for assessing the risk of developing VWF.
Numerical Analysis of Stochastic Dynamical Systems in the Medium-Frequency Range
2003-02-01
frequency vibration analysis such as the statistical energy analysis (SEA), the traditional modal analysis (well-suited for high and low: frequency...that the first few structural normal modes primarily constitute the total response. In the higher frequency range, the statistical energy analysis (SEA
Accurate step-FMCW ultrasound ranging and comparison with pulse-echo signaling methods
NASA Astrophysics Data System (ADS)
Natarajan, Shyam; Singh, Rahul S.; Lee, Michael; Cox, Brian P.; Culjat, Martin O.; Grundfest, Warren S.; Lee, Hua
2010-03-01
This paper presents a method setup for high-frequency ultrasound ranging based on stepped frequency-modulated continuous waves (FMCW), potentially capable of producing a higher signal-to-noise ratio (SNR) compared to traditional pulse-echo signaling. In current ultrasound systems, the use of higher frequencies (10-20 MHz) to enhance resolution lowers signal quality due to frequency-dependent attenuation. The proposed ultrasound signaling format, step-FMCW, is well-known in the radar community, and features lower peak power, wider dynamic range, lower noise figure and simpler electronics in comparison to pulse-echo systems. In pulse-echo ultrasound ranging, distances are calculated using the transmit times between a pulse and its subsequent echoes. In step-FMCW ultrasonic ranging, the phase and magnitude differences at stepped frequencies are used to sample the frequency domain. Thus, by taking the inverse Fourier transform, a comprehensive range profile is recovered that has increased immunity to noise over conventional ranging methods. Step-FMCW and pulse-echo waveforms were created using custom-built hardware consisting of an arbitrary waveform generator and dual-channel super heterodyne receiver, providing high SNR and in turn, accuracy in detection.
Zhao, Huawei; Crozier, Stuart; Liu, Feng
2002-12-01
Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model. Copyright 2002 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Zhou, D. F.; Li, J.; Hansen, C. H.
2011-11-01
Track-induced self-excited vibration is commonly encountered in EMS (electromagnetic suspension) maglev systems, and a solution to this problem is important in enabling the commercial widespread implementation of maglev systems. Here, the coupled model of the steel track and the magnetic levitation system is developed, and its stability is investigated using the Nyquist criterion. The harmonic balance method is employed to investigate the stability and amplitude of the self-excited vibration, which provides an explanation of the phenomenon that track-induced self-excited vibration generally occurs at a specified amplitude and frequency. To eliminate the self-excited vibration, an improved LMS (Least Mean Square) cancellation algorithm with phase correction (C-LMS) is employed. The harmonic balance analysis shows that the C-LMS cancellation algorithm can completely suppress the self-excited vibration. To achieve adaptive cancellation, a frequency estimator similar to the tuner of a TV receiver is employed to provide the C-LMS algorithm with a roughly estimated reference frequency. Numerical simulation and experiments undertaken on the CMS-04 vehicle show that the proposed adaptive C-LMS algorithm can effectively eliminate the self-excited vibration over a wide frequency range, and that the robustness of the algorithm suggests excellent potential for application to EMS maglev systems.
The frequency of dyscalculia among primary school children.
Jovanović, Gordana; Jovanović, Zoran; Banković-Gajić, Jelena; Nikolić, Anđelka; Svetozarević, Srđana; Ignjatović-Ristić, Dragana
2013-06-01
Formal education, daily living activities and jobs require knowledge and application skills of counting and simple mathematical operations. Problems with mathematics start in primary school and persist till adulthood. This is known as dyscalculia and its prevalence in the school population ranges from 3 to 6.5%. The study included 1424 third-grade students (aged 9-10) of all primary schools in the City of Kragujevac, Serbia. Tests in mathematics were given in order to determine their mathematical achievement. 1078 students (538 boys and 540 girls) completed all five tests. The frequency of dyscalculia in the sample was 9.9%. The difference between boys and girls according to the total score on the test was statistically significant (p<0.005). The difference between students according to their school achievement (excellent, very good, good, sufficient and insufficient) was statistically significant for all tests (p<0.0005). The influence of place of residence/school was significant for all tests (p<0.0005). Independent prognostic variables associated with dyscalculia are marks in mathematics and Serbian language. Frequency of dyscalculia of 9.9% in the sample is higher than in the other similar studies. Further research should identify possible causes of such frequency of dyscalculia in order to improve students` mathematical abilities.
Sahin, Sevil; Ozdemir, Kevser; Unsal, Alaattin; Arslan, Refika
2014-01-01
To determine the frequency of dysmenorrhea in university students, review some associated factors and evaluate the relationship between dysmenorrhea and sleep quality. The study group included 520 students. Survey forms prepared previously in line with the study objective were completed by the students under supervision. The severity of dysmenorrhea was rated with Visual Analogue Scale. Pittsburgh Sleep Quality Index was used to evaluate the sleep quality. The χ(2) test, Mann-Whitney U test and Kruskal-Wallis test were used for the analyses. Statistical significance level was accepted at p < 0.05. Mean age of the students was 20.23 ± 1.59 years (range 17-25). Frequency of dysmenorrhea was determined to be 69.0% (n = 359). Frequency of dysmenorrhea was higher in smokers, those with menstrual irregularity, those who use drugs for menstrual regulation and those having a family history (p < 0.05 for each). The most frequent symptoms in those having dysmenorrhea history were weakness (59.6%), fatigue (58.5%) and breast tenderness (45.4%), respectively. Sleep quality was found to be poorer in the students having a history of dysmenorrhea (p < 0.05). Dysmenorrhea is an important health problem in young women. Dysmenorrhea affects the sleep quality negatively. © 2014 S. Karger AG, Basel.
Streaming driven by sessile microbubbles: Explaining flow patterns and frequency response
NASA Astrophysics Data System (ADS)
Rallabandi, Bhargav; Wang, Cheng; Guo, Lin; Hilgenfeldt, Sascha
2013-11-01
Ultrasound excitation of bubbles drives powerful steady streaming flows which have found widespread applications in microfluidics, where bubbles are typically of semicircular cross section and attached to walls of the device (sessile). While bubble-driven streaming in bulk fluid is well understood, this practically relevant case presents additional complexity introduced by the wall and contact lines. We develop an asymptotic theory that takes into account the presence of the wall as well as the oscillation dynamics of the bubble, providing a complete description of the streaming flow as a function only of the driving frequency, the bubble size, and the physical properties of the fluid. We show that the coupling between different bubble oscillation modes sustains the experimentally observed streaming flow vortex pattern over a broad range of frequencies, greatly exceeding the widths of individual mode resonances. Above a threshold frequency, we predict, and observe in experiment, reversal of the flow direction. Our analytical theory can be used to guide the design of microfluidic devices, both in situations where robust flow patterns insensitive to parameter changes are desired (e.g. lab-on-a-chip sorters), and in cases where intentional modulation of the flow field appearance is key (e.g. efficient mixers). Current address: Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology.
Villanea, Fernando A.; Safi, Kristin N.; Busch, Jeremiah W.
2015-01-01
The ABO locus in humans is characterized by elevated heterozygosity and very similar allele frequencies among populations scattered across the globe. Using knowledge of ABO protein function, we generated a simple model of asymmetric negative frequency dependent selection and genetic drift to explain the maintenance of ABO polymorphism and its loss in human populations. In our models, regardless of the strength of selection, models with large effective population sizes result in ABO allele frequencies that closely match those observed in most continental populations. Populations must be moderately small to fall out of equilibrium and lose either the A or B allele (Ne ≤ 50) and much smaller (N e ≤ 25) for the complete loss of diversity, which nearly always involved the fixation of the O allele. A pattern of low heterozygosity at the ABO locus where loss of polymorphism occurs in our model is consistent with small populations, such as Native American populations. This study provides a general evolutionary model to explain the observed global patterns of polymorphism at the ABO locus and the pattern of allele loss in small populations. Moreover, these results inform the range of population sizes associated with the recent human colonization of the Americas. PMID:25946124
Evaluation of a Validated Food Frequency Questionnaire for Self-Defined Vegans in the United States
Dyett, Patricia; Rajaram, Sujatha; Haddad, Ella H.; Sabate, Joan
2014-01-01
This study aimed to develop and validate a de novo food frequency questionnaire for self-defined vegans in the United States. Diet histories from pilot samples of vegans and a modified ‘Block Method’ using seven selected nutrients of concern in vegan diet patterns, were employed to generate the questionnaire food list. Food frequency responses of 100 vegans from 19 different U.S. states were obtained via completed mailed questionnaires and compared to multiple telephone-conducted diet recall interviews. Computerized diet analyses were performed. Correlation coefficients, t-tests, rank, cross-tabulations, and probability tests were used to validate and compare intake estimates and dietary reference intake (DRI) assessment trends between the two methods. A 369-item vegan-specific questionnaire was developed with 252 listed food frequency items. Calorie-adjusted correlation coefficients ranged from r = 0.374 to 0.600 (p < 0.001) for all analyzed nutrients except calcium. Estimates, ranks, trends and higher-level participant percentile placements for Vitamin B12 were similar with both methods. Questionnaire intakes were higher than recalls for most other nutrients. Both methods demonstrated similar trends in DRI adequacy assessment (e.g., significantly inadequate vitamin D intake among vegans). This vegan-specific questionnaire can be a useful assessment tool for health screening initiatives in U.S. vegan communities. PMID:25006856
Evaluation of a validated food frequency questionnaire for self-defined vegans in the United States.
Dyett, Patricia; Rajaram, Sujatha; Haddad, Ella H; Sabate, Joan
2014-07-08
This study aimed to develop and validate a de novo food frequency questionnaire for self-defined vegans in the United States. Diet histories from pilot samples of vegans and a modified 'Block Method' using seven selected nutrients of concern in vegan diet patterns, were employed to generate the questionnaire food list. Food frequency responses of 100 vegans from 19 different U.S. states were obtained via completed mailed questionnaires and compared to multiple telephone-conducted diet recall interviews. Computerized diet analyses were performed. Correlation coefficients, t-tests, rank, cross-tabulations, and probability tests were used to validate and compare intake estimates and dietary reference intake (DRI) assessment trends between the two methods. A 369-item vegan-specific questionnaire was developed with 252 listed food frequency items. Calorie-adjusted correlation coefficients ranged from r = 0.374 to 0.600 (p < 0.001) for all analyzed nutrients except calcium. Estimates, ranks, trends and higher-level participant percentile placements for Vitamin B12 were similar with both methods. Questionnaire intakes were higher than recalls for most other nutrients. Both methods demonstrated similar trends in DRI adequacy assessment (e.g., significantly inadequate vitamin D intake among vegans). This vegan-specific questionnaire can be a useful assessment tool for health screening initiatives in U.S. vegan communities.
Manufacturing of super-polished large aspheric/freeform optics
NASA Astrophysics Data System (ADS)
Kim, Dae Wook; Oh, Chang-jin; Lowman, Andrew; Smith, Greg A.; Aftab, Maham; Burge, James H.
2016-07-01
Several next generation astronomical telescopes or large optical systems utilize aspheric/freeform optics for creating a segmented optical system. Multiple mirrors can be combined to form a larger optical surface or used as a single surface to avoid obscurations. In this paper, we demonstrate a specific case of the Daniel K. Inouye Solar Telescope (DKIST). This optic is a 4.2 m in diameter off-axis primary mirror using ZERODUR thin substrate, and has been successfully completed in the Optical Engineering and Fabrication Facility (OEFF) at the University of Arizona, in 2016. As the telescope looks at the brightest object in the sky, our own Sun, the primary mirror surface quality meets extreme specifications covering a wide range of spatial frequency errors. In manufacturing the DKIST mirror, metrology systems have been studied, developed and applied to measure low-to-mid-to-high spatial frequency surface shape information in the 4.2 m super-polished optical surface. In this paper, measurements from these systems are converted to Power Spectral Density (PSD) plots and combined in the spatial frequency domain. Results cover 5 orders of magnitude in spatial frequencies and meet or exceed specifications for this large aspheric mirror. Precision manufacturing of the super-polished DKIST mirror enables a new level of solar science.
Buried Object Detection Method Using Optimum Frequency Range in Extremely Shallow Underground
NASA Astrophysics Data System (ADS)
Sugimoto, Tsuneyoshi; Abe, Touma
2011-07-01
We propose a new detection method for buried objects using the optimum frequency response range of the corresponding vibration velocity. Flat speakers and a scanning laser Doppler vibrometer (SLDV) are used for noncontact acoustic imaging in the extremely shallow underground. The exploration depth depends on the sound pressure, but it is usually less than 10 cm. Styrofoam, wood (silver fir), and acrylic boards of the same size, different size styrofoam boards, a hollow toy duck, a hollow plastic container, a plastic container filled with sand, a hollow steel can and an unglazed pot are used as buried objects which are buried in sand to about 2 cm depth. The imaging procedure of buried objects using the optimum frequency range is given below. First, the standardized difference from the average vibration velocity is calculated for all scan points. Next, using this result, underground images are made using a constant frequency width to search for the frequency response range of the buried object. After choosing an approximate frequency response range, the difference between the average vibration velocity for all points and that for several points that showed a clear response is calculated for the final confirmation of the optimum frequency range. Using this optimum frequency range, we can obtain the clearest image of the buried object. From the experimental results, we confirmed the effectiveness of our proposed method. In particular, a clear image of the buried object was obtained when the SLDV image was unclear.
Vorobyov, Vasily; Kaptsov, Vladimir; Kovalev, Georgy; Sengpiel, Frank
2011-05-30
To study the effects of acute and repeated injections of nootropics and to learn how glutamate receptors might be involved in their mediation, the frequency spectra of cortical and hippocampal electroencephalogram (EEG) were analyzed in non-narcotized rats subcutaneously injected repeatedly with Piracetam (400mg/kg) or its analogue, Noopept (0.2mg/kg), after intracerebroventricular infusions of saline (5 μl) or the antagonists of NMDA and quisqualate/AMPA receptors: CPP (0.1 nmol) and GDEE (1 μmol), respectively. Piracetam increased alpha/beta1 EEG activity in the left frontal cortex, and alpha activity in both the right cortex and hippocampus, with a 10-min latency and 40-min duration. Noopept increased alpha/beta1 activity, with 30-min latency and 40-min duration in all brain areas. CPP pretreatment eliminated Piracetam EEG effects; reduced Noopept effects in the cortex and completely suppressed them in the hippocampus. After four injections of Piracetam, EEG effects were very small in the cortex, and completely lacking in the hippocampus, while GDEE pretreatment partially recovered them. The effect of Noopept in the alpha/beta1 ranges was replaced by increased beta2 activity after the eighth injection, while no effects were observed after the ninth one. GDEE pretreatment restored the effect of Noopept in the beta2 frequency range. These results demonstrate similarities in EEG effects and their mediatory mechanisms for Piracetam and its much more effective analogue, Noopept. Activation of NMDA receptors is involved in the effects of a single injection of the nootropics, whereas activation of quisqualate/AMPA receptors is associated with the decrease in their efficacy after repeated use. Copyright © 2011 Elsevier Inc. All rights reserved.
An Overview of the NIRA Status
NASA Technical Reports Server (NTRS)
Hughes, William
2003-01-01
The NASA Glenn Research Center (GRC) has been tasked by NASA JSC's ISS Payloads Office to perform the NIRA (Non-Isolated Rack Assessment) microgravity prediction analysis task for the International Space Station. Previously, the NIRA analysis task had been performed by Boeing/Houston. Boeing's last NIRA analysis was released in 1999 and was denoted as "NIRA 99." GRC is currently close to completing our first full-NIRA analysis (encompassing the frequency range from 0 to 50 Hz) to be released as "NIRA 2003." This presentation will focus on describing the NIRA analysis, the transition of this analysis task from Boeing to GRC, and the current status and schedule for release of the NIRA 2003 results. Additionally, the results obtained from a mini-NIRA analysis requested by ESA and completed by GRC in the Spring of 2003 will be shown. This mini-analysis focused solely on predicting the microgravity environment at the COF-EPF (Columbus Orbiting Facility - External Payload Facility).
NASA Technical Reports Server (NTRS)
Wong, R. C.; Owen, H. A., Jr.; Wilson, T. G.; Rodriguez, G. E.
1980-01-01
Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.
Newsvendor problem under complete uncertainty: a case of innovative products.
Gaspars-Wieloch, Helena
2017-01-01
The paper presents a new scenario-based decision rule for the classical version of the newsvendor problem (NP) under complete uncertainty (i.e. uncertainty with unknown probabilities). So far, NP has been analyzed under uncertainty with known probabilities or under uncertainty with partial information (probabilities known incompletely). The novel approach is designed for the sale of new, innovative products, where it is quite complicated to define probabilities or even probability-like quantities, because there are no data available for forecasting the upcoming demand via statistical analysis. The new procedure described in the contribution is based on a hybrid of Hurwicz and Bayes decision rules. It takes into account the decision maker's attitude towards risk (measured by coefficients of optimism and pessimism) and the dispersion (asymmetry, range, frequency of extremes values) of payoffs connected with particular order quantities. It does not require any information about the probability distribution.
Sweet taste preference in binge-eating disorder: A preliminary investigation.
Goodman, Erica L; Breithaupt, Lauren; Watson, Hunna J; Peat, Christine M; Baker, Jessica H; Bulik, Cynthia M; Brownley, Kimberly A
2018-01-01
Research suggests that individuals with high liking for sweets are at increased risk for binge eating, which has been minimally investigated in individuals with binge-eating disorder (BED). Forty-one adults (85% female, 83% white) with binge eating concerns completed a sweet taste test and measures of eating disorder behaviors and food cravings. A subset of participants with BED completed an oral glucose tolerance test (OGTT; N=21) and a 24-hour dietary recall (N=26). Regression models were used to compare highest sweet preferers (HSP [N=18]) to other sweet preferers (OSP [N=23]) and were used to assess associations between sweet taste preference and outcome variables. Effect sizes (ηp 2 ) for differences between HSP and OSP ranged from small (≤0.01) to large (≥0.24); group differences were statistically nonsignificant except for 24-hour caloric intake (ηp 2 =0.16, p=0.04), protein intake (ηp 2 =0.16, p=0.04), and insulin sensitivity index (ηp 2 =0.24, p=0.04), which were higher in HSP, and postprandial insulin, which was smaller in HSP (ηp 2 =0.27, p=0.03). Continuous analyses replicated postprandial insulin response. Compared with OSP, HSP reported numerically higher binge-eating frequency (ηp 2 =0.04), over-eating frequency (ηp 2 =0.06), and carbohydrate intake (ηp 2 =0.14), and they exhibited numerically smaller postprandial glucose AUC (ηp 2 =0.16). Sweet taste preference may have implications for glucose regulation, binge-eating frequency, and nutrient intake in BED. Copyright © 2017 Elsevier Ltd. All rights reserved.
Moore, Lynne; Hanley, James A; Lavoie, André; Turgeon, Alexis
2009-05-01
The National Trauma Data Bank (NTDB) is plagued by the problem of missing physiological data. The Glasgow Coma Scale score, Respiratory Rate and Systolic Blood Pressure are an essential part of risk adjustment strategies for trauma system evaluation and clinical research. Missing data on these variables may compromise the feasibility and the validity of trauma group comparisons. To evaluate the validity of Multiple Imputation (MI) for completing missing physiological data in the National Trauma Data Bank (NTDB), by assessing the impact of MI on 1) frequency distributions, 2) associations with mortality, and 3) risk adjustment. Analyses were based on 170,956 NTDB observations with complete physiological data (observed data set). Missing physiological data were artificially imposed on this data set and then imputed using MI (MI data set). To assess the impact of MI on risk adjustment, 100 pairs of hospitals were randomly selected with replacement and compared using adjusted Odds Ratios (OR) of mortality. OR generated by the observed data set were then compared to those generated by the MI data set. Frequency distributions and associations with mortality were preserved following MI. The median absolute difference between adjusted OR of mortality generated by the observed data set and by the MI data set was 3.6% (inter-quartile range: 2.4%-6.1%). This study suggests that, provided it is implemented with care, MI of missing physiological data in the NTDB leads to valid frequency distributions, preserves associations with mortality, and does not compromise risk adjustment in inter-hospital comparisons of mortality.
Synthetic range profiling in ground penetrating radar
NASA Astrophysics Data System (ADS)
Kaczmarek, Pawel; Lapiński, Marian; Silko, Dariusz
2009-06-01
The paper describes stepped frequency continuous wave (SFCW) ground penetrating radar (GPR), where signal's frequency is discretely increased in N linear steps, each separated by a fixed ▵f increment from the previous one. SFCW radar determines distance from phase shift in a reflected signal, by constructing synthetic range profile in spatial time domain using the IFFT. Each quadrature sample is termed a range bin, as it represents the signal from a range window of length cτ/2, where τ is duration of single frequency segment. IFFT of those data samples resolves the range bin in into fine range bins of c/2N▵f width, thus creating the synthetic range profile in a GPR - a time domain approximation of the frequency response of a combination of the medium through which electromagnetic waves propagates (soil) and any targets or dielectric interfaces (water, air, other types of soil) present in the beam width of the radar. In the paper, certain practical measurements done by a monostatic SFCW GPR were presented. Due to complex nature of signal source, E5062A VNA made by Agilent was used as a signal generator, allowing number of frequency steps N to go as high as 1601, with generated frequency ranging from 300kHz to 3 GHz.
Szabolcsi, Zoltán; Farkas, Zsuzsa; Borbély, Andrea; Bárány, Gusztáv; Varga, Dániel; Heinrich, Attila; Völgyi, Antónia; Pamjav, Horolma
2015-11-01
When the DNA profile from a crime-scene matches that of a suspect, the weight of DNA evidence depends on the unbiased estimation of the match probability of the profiles. For this reason, it is required to establish and expand the databases that reflect the actual allele frequencies in the population applied. 21,473 complete DNA profiles from Databank samples were used to establish the allele frequency database to represent the population of Hungarian suspects. We used fifteen STR loci (PowerPlex ESI16) including five, new ESS loci. The aim was to calculate the statistical, forensic efficiency parameters for the Databank samples and compare the newly detected data to the earlier report. The population substructure caused by relatedness may influence the frequency of profiles estimated. As our Databank profiles were considered non-random samples, possible relationships between the suspects can be assumed. Therefore, population inbreeding effect was estimated using the FIS calculation. The overall inbreeding parameter was found to be 0.0106. Furthermore, we tested the impact of the two allele frequency datasets on 101 randomly chosen STR profiles, including full and partial profiles. The 95% confidence interval estimates for the profile frequencies (pM) resulted in a tighter range when we used the new dataset compared to the previously published ones. We found that the FIS had less effect on frequency values in the 21,473 samples than the application of minimum allele frequency. No genetic substructure was detected by STRUCTURE analysis. Due to the low level of inbreeding effect and the high number of samples, the new dataset provides unbiased and precise estimates of LR for statistical interpretation of forensic casework and allows us to use lower allele frequencies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Smith, Andrew M.; Davis, R. Benjamin; LaVerde, Bruce T.; Fulcher, Clay W.; Jones, Douglas C.; Waldon, James M.; Craigmyle, Benjamin B.
2012-01-01
This validation study examines the effect on vibroacoustic response resulting from the installation of cable bundles on a curved orthogrid panel. Of interest is the level of damping provided by the installation of the cable bundles and whether this damping could be potentially leveraged in launch vehicle design. The results of this test are compared with baseline acoustic response tests without cables. Damping estimates from the measured response data are made using a new software tool that leverages a finite element model of the panel in conjunction with advanced optimization techniques. While the full test series is not yet complete, the first configuration of cable bundles that was assessed effectively increased the viscous critical damping fraction of the system by as much as 0.02 in certain frequency ranges.
Investigation of critical burning of fuel droplets. [monopropellants
NASA Technical Reports Server (NTRS)
Faeth, G. M.; Chanin, S.
1974-01-01
The steady combustion characteristics of droplets were considered in combustion chamber environments at various pressures, flow conditions, and ambient oxidizer concentrations for a number of hydrocarbon fuels. Using data obtained earlier, predicted gasification rates were within + or - 30% of measurements when the correction for convection was based upon average properties between the liquid surface and the flame around the droplet. Analysis was also completed for the open loop response of monopropellant droplets, based upon earlier strand combustion results. At the limit of large droplets, where the effect of flame curvature is small, the results suggest sufficient response to provide a viable mechanism for combustion instability in the frequency and droplet size range appropriate to practical combustors. Calculations are still in progress for a broader range of droplet sizes, including conditions where active combustion effects are small.
The Jansky VLA: Rebuilt for 21st Century Astronomy
NASA Astrophysics Data System (ADS)
Hallinan, Gregg
2016-01-01
At the start of this decade, the Very Large Array underwent a transformative upgrade. While retaining its original 27 antennas, the signal transmission and processing systems, originally developed and built in the 1970s, have been replaced with state of the art wideband receivers and a new data transmission system, as well as one of the most powerful correlators yet built. With a ten-fold increase in continuum sensitivity, up to 4 million frequency channels and complete frequency coverage from 1-50 GHz, the resulting increase in capability and versatility is analogous to the transition from photographic plate to CCD technology that revolutionized optical astronomy in the 1980s. Post upgrade, the Jansky VLA will be the most sensitive radio interferometer in the world for this decade, probing the sub-uJy radio sky for the first time, and will remain the most versatile, frequency-agile radio telescope for the foreseeable future. Underscoring this versatility, is the VLA's capability to trace both thermal and non-thermal emission over a wide range of spatial, time and velocity resolution. At the highest frequencies, this includes imaging cool gas in high redshift galaxies and dusty disks in nearby protoplanetary systems, while at the lowest frequencies tracing AGN activity and star formation back to the epoch of reionization. In the time domain, the VLA can respond to external triggers within 15 minutes to provide an instantaneous broadband radio spectrum of explosive events. I will review some of the exciting science emerging from the Jansky VLA as well as the range of science-ready data products that will make the VLA increasingly accessible to the wider astronomical community. Finally, I will briefly introduce the new VLA Sky Survey (VLASS), a community-driven project to image 80% of the sky over multiple epochs with the VLA, reaching a depth of ~70 uJy and detecting ~10 million radio sources at high spatial and spectral resolution with full polarization information.
ERIC Educational Resources Information Center
Wiecha, John M.; And Others
1994-01-01
Vietnamese high school students completed a food frequency questionnaire (FFQ) and completed daily diet reports for seven weeks. Data from the FFQ were compared to the food reports. The results indicated a few simple FFQ items, particularly for indicator foods such as rice, were reliable for dietary assessment for that population. (SM)
Range-gated field disturbance sensor with range-sensitivity compensation
McEwan, T.E.
1996-05-28
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudorandomly modulated so that bursts in the sequence of bursts have a phase which varies. 8 figs.
Range-gated field disturbance sensor with range-sensitivity compensation
McEwan, Thomas E.
1996-01-01
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudorandomly modulated so that bursts in the sequence of bursts have a phase which varies.
Tsai, Tsung-Han; Zhou, Chao; Adler, Desmond C; Fujimoto, James G
2009-11-09
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a approximately -1.2dB sensitivity roll off over approximately 3mm range, compared to conventional swept source and FDML lasers which have -10dB and -5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0-3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed.
Tsai, Tsung-Han; Zhou, Chao; Adler, Desmond C.; Fujimoto, James G.
2010-01-01
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a ~−1.2dB sensitivity roll off over ~3mm range, compared to conventional swept source and FDML lasers which have −10dB and −5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0–3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed. PMID:19997365
An audit of the completion of radiology request forms and the request practice
Akintomide, Akintunde O.; Ikpeme, Anthonia A.; Ngaji, Affiong I.; Ani, Nchiewe E.; Udofia, Appolline T.
2015-01-01
Objective: To assess the degree of utilization of the radiology request form (RRF), the extent of completion each form, the frequency of filling the fields in all the forms, and its effectiveness as a communication tool between the referring clinicians and radiologists. Materials and Methods: All the RRFs for conventional radiographic examinations were audited over a 3-month period. A database containing all the fields in the form, type of request paper used, and legibility of the physician's handwriting was created. A few resident radiologists in the plain film reporting unit were recruited to join in collecting the data daily. We used simple statistical methods to analyze the extent of completion of each form, frequency of completion of the fields in all the request forms, frequency of use of the appropriate form, and frequency of legibility of the physician's handwriting. The results are expressed in percentages. Results: Five hundred eighty (580) requests were analyzed, consisting of 180 for males and 400 for females. The most-completed request form was 86.67% filled, while the least-completed was 26.67%. The most frequently filled field was the requested examination (99.66%). Of the clinicians, 28% did not use the RRF for their referrals, while 7.37% had illegible handwriting. Conclusion: A significant number of the referring clinicians did not make the best use of the radiology department by not using the institution's approved RRF as an effective means of communication with the radiologists, mainly due to the inadequate completion of the forms. PMID:26288767
NASA Astrophysics Data System (ADS)
Gao, Shanghua; Xue, Bing
2017-04-01
The dynamic range of the currently most widely used 24-bit seismic data acquisition devices is 10-20 dB lower than that of broadband seismometers, and this can affect the completeness of seismic waveform recordings under certain conditions. However, this problem is not easy to solve because of the lack of analog to digital converter (ADC) chips with more than 24 bits in the market. So the key difficulties for higher-resolution data acquisition devices lie in achieving more than 24-bit ADC circuit. In the paper, we propose a method in which an adder, an integrator, a digital to analog converter chip, a field-programmable gate array, and an existing low-resolution ADC chip are used to build a third-order 16-bit oversampling delta-sigma modulator. This modulator is equipped with a digital decimation filter, thus forming a complete analog to digital converting circuit. Experimental results show that, within the 0.1-40 Hz frequency range, the circuit board's dynamic range reaches 158.2 dB, its resolution reaches 25.99 dB, and its linearity error is below 2.5 ppm, which is better than what is achieved by the commercial 24-bit ADC chips ADS1281 and CS5371. This demonstrates that the proposed method may alleviate or even solve the amplitude-limitation problem that broadband observation systems so commonly have to face during strong earthquakes.
Steering optical comb frequencies by rotating the polarization state
NASA Astrophysics Data System (ADS)
Zhang, Yanyan; Zhang, Xiaofei; Yan, Lulu; Zhang, Pan; Rao, Bingjie; Han, Wei; Guo, Wenge; Zhang, Shougang; Jiang, Haifeng
2017-12-01
Optical frequency combs, with precise control of repetition rate and carrier-envelope-offset frequency, have revolutionized many fields, such as fine optical spectroscopy, optical frequency standards, ultra-fast science research, ultra-stable microwave generation and precise ranging measurement. However, existing high bandwidth frequency control methods have small dynamic range, requiring complex hybrid control techniques. To overcome this limitation, we develop a new approach, where a home-made intra-cavity electro-optic modulator tunes polarization state of laser signal rather than only optical length of the cavity, to steer frequencies of a nonlinear-polarization-rotation mode-locked laser. By taking advantage of birefringence of the whole cavity, this approach results in not only broadband but also relative large-dynamic frequency control. Experimental results show that frequency control dynamic range increase at least one order in comparison with the traditional intra-cavity electro-optic modulator technique. In additional, this technique exhibits less side-effect than traditional frequency control methods.
Nelson, Paul C; Smith, Zachary M; Young, Eric D
2009-02-25
An organism's ability to detect and discriminate sensory inputs depends on the recent stimulus history. For example, perceptual detection thresholds for a brief tone can be elevated by as much as 50 dB when following a masking stimulus. Previous work suggests that such forward masking is not a direct result of peripheral neural adaptation; the central pathway apparently modifies the representation in a way that further attenuates the input's response to short probe signals. Here, we show that much of this transformation is complete by the level of the inferior colliculus (IC). Single-neuron extracellular responses were recorded in the central nucleus of the awake marmoset IC. The threshold for a 20 ms probe tone presented at best frequency was determined for various masker-probe delays, over a range of masker sound pressure levels (SPLs) and frequencies. The most striking aspect of the data was the increased potency of forward maskers as their SPL was increased, despite the fact that the excitatory response to the masker was often saturating or nonmonotonic over the same range of levels. This led to probe thresholds at high masker levels that were almost always higher than those observed in the auditory nerve. Probe threshold shifts were not usually caused by a persistent excitatory response to the masker; instead we propose a wide-dynamic-range inhibitory mechanism locked to sound offset as an explanation for several key aspects of the data. These findings further delineate the role of subcortical auditory processing in the generation of a context-dependent representation of ongoing acoustic scenes.
Nelson, Paul C.; Smith, Zachary M.; Young, Eric D.
2009-01-01
An organism’s ability to detect and discriminate sensory inputs depends on the recent stimulus history. For example, perceptual detection thresholds for a brief tone can be elevated by as much as 50 dB when following a masking stimulus. Previous work suggests that such forward masking is not a direct result of peripheral neural adaptation; the central pathway apparently modifies the representation in a way that further attenuates the input’s response to short probe signals. Here, we show that much of this transformation is complete by the level of the inferior colliculus (IC). Single-neuron extracellular responses were recorded in the central nucleus of the awake marmoset IC. The threshold for a 20-ms probe tone presented at best frequency was determined for various masker-probe delays, over a range of masker SPLs and frequencies. The most striking aspect of the data was the increased potency of forward maskers as their SPL was increased, despite the fact that the excitatory response to the masker was often saturating or non-monotonic over the same range of levels. This led to probe thresholds at high masker levels that were almost always higher than those observed in the auditory nerve. Probe threshold shifts were not usually caused by a persistent excitatory response to the masker; instead we propose a wide dynamic-range inhibitory mechanism locked to sound offset as an explanation for several key aspects of the data. These findings further delineate the role of subcortical auditory processing in the generation of a context-dependent representation of ongoing acoustic scenes. PMID:19244530
Near-Earth-object survey progress and population of small near-Earth asteroids
NASA Astrophysics Data System (ADS)
Harris, A.
2014-07-01
Estimating the total population vs. size of NEAs and the completion of surveys is the same thing since the total population is just the number discovered divided by the estimated completion. I review the method of completion estimation based on ratio of re-detected objects to total detections (known plus new discoveries). The method is quite general and can be used for population estimations of all sorts, from wildlife to various classes of solar system bodies. Since 2001, I have been making estimates of population and survey progress approximately every two years. Plotted below, left, is my latest estimate, including NEA discoveries up to August, 2012. I plan to present an update at the meeting. All asteroids of a given size are not equally easy to detect because of specific orbital geometries. Thus a model of the orbital distribution is necessary, and computer simulations using those orbits need to establish the relation between the raw re-detection ratio and the actual completion fraction. This can be done for any sub-group population, allowing to estimate the population of a subgroup and the expected current completion. Once a reliable survey computer model has been developed and ''calibrated'' with respect to actual survey re-detections versus size, it can be extrapolated to smaller sizes to estimate completion even at very small size where re-detections are rare or even zero. I have recently investigated the subgroup of extremely low encounter velocity NEAs, the class of interest for the Asteroid Redirect Mission (ARM), recently proposed by NASA. I found that asteroids of diameter ˜ 10 m with encounter velocity with the Earth lower than 2.5 km/sec are detected by current surveys nearly 1,000 times more efficiently than the general background of NEAs of that size. Thus the current completion of these slow relative velocity objects may be around 1%, compared to 10^{-6} for that size objects of the general velocity distribution. Current surveys are nowhere near complete, but there may be fewer such objects than have been suggested. This conclusion is reinforced by the fact that at least a couple such discovered objects are known to be not real asteroids but spent rocket bodies in heliocentric orbit, of which there are only of the order of a hundred. Brown et al. (Nature 503, 238-241, 2013, below right, green squares are a re-plot of my blue circles on left plot) recently suggested that the population of small NEAs in the size range from roughly 5 to 50 meters in diameter may have been substantially under-estimated. To be sure, the greatest uncertainty in population estimates is in that range, since there are very few bolide events to use for estimation, and the surveys are extremely incomplete in that size range, so a factor of 3 or so discrepancy is not significant. However, the population estimated from surveys carried still smaller, where the bolide frequency becomes more secure, disagrees from the bolide estimate by even less than a factor of 3 and in fact intersects at about 3 m diameter. On the other hand, the shallow-sloping size-frequency distribution derived from the sparse large bolide data diverges badly from the survey estimates, in sizes where the survey estimates become ever-increasingly reliable, even by 100-200 m diameter. It appears that the bolide data provides a good "anchor" of the population in the size range up to about 5 m diameter, but above that one might do better just connecting that population with a straight line (on a log-log plot) with the survey-determined population at larger size, 50-100 m diameter or so.
Alumina or Semiconductor Ribbon Waveguides at 30 to 1,000 GHz
NASA Technical Reports Server (NTRS)
Yeh, Cavour; Rascoe, Daniel; Shimabukuro, Fred; Tope, Michael; Siegel, Peter
2005-01-01
Ribbon waveguides made of alumina or of semiconductors (Si, InP, or GaAs) have been proposed as low-loss transmission lines for coupling electronic components and circuits that operate at frequencies from 30 to 1,000 GHz. In addition to low losses (and a concomitant ability to withstand power levels higher than would otherwise be possible), the proposed ribbon waveguides would offer the advantage of compatibility with the materials and structures now commonly incorporated into integrated circuits. Heretofore, low-loss transmission lines for this frequency range have been unknown, making it necessary to resort to designs that, variously, place circuits and components to be coupled in proximity of each other and/or provide for coupling via free space through bulky and often lossy optical elements. Even chip-to-chip interconnections have been problematic in this frequency range. Metal wave-guiding structures (e.g., microstriplines and traditional waveguides) are not suitable for this frequency range because the skin depths of electromagnetic waves in this frequency range are so small as to give rise to high losses. Conventional rod-type dielectric waveguide structures are also not suitable for this frequency range because dielectric materials, including ones that exhibit ultralow losses at lower frequencies, exhibit significant losses in this frequency range. Unlike microstripline structures or metallic waveguides, the proposed ribbon waveguides would be free of metal and would therefore not be subject to skin-depth losses. Moreover, although they would be made of materials that are moderately lossy in the frequency range of interest, the proposed ribbon waveguides would cause the propagating electromagnetic waves to configure themselves in a manner that minimizes losses.
Chen, Runlin; Wei, Yangyang; Shi, Zhaoyang; Yuan, Xiaoyang
2016-01-01
The identification accuracy of dynamic characteristics coefficients is difficult to guarantee because of the errors of the measurement system itself. A novel dynamic calibration method of measurement system for dynamic characteristics coefficients is proposed in this paper to eliminate the errors of the measurement system itself. Compared with the calibration method of suspension quality, this novel calibration method is different because the verification device is a spring-mass system, which can simulate the dynamic characteristics of sliding bearing. The verification device is built, and the calibration experiment is implemented in a wide frequency range, in which the bearing stiffness is simulated by the disc springs. The experimental results show that the amplitude errors of this measurement system are small in the frequency range of 10 Hz–100 Hz, and the phase errors increase along with the increasing of frequency. It is preliminarily verified by the simulated experiment of dynamic characteristics coefficients identification in the frequency range of 10 Hz–30 Hz that the calibration data in this frequency range can support the dynamic characteristics test of sliding bearing in this frequency range well. The bearing experiments in greater frequency ranges need higher manufacturing and installation precision of calibration device. Besides, the processes of calibration experiments should be improved. PMID:27483283
Video Head Impulse Testing (vHIT) and the Assessment of Horizontal Semicircular Canal Function.
Riska, Kristal M; Murnane, Owen; Akin, Faith W; Hall, Courtney
2015-05-01
Vestibular function (specifically, horizontal semicircular canal function) can be assessed across a broad frequency range using several different techniques. The head impulse test is a qualitative test of horizontal semicircular canal function that can be completed at bedside. Recently, a new instrument (video head impulse test [vHIT]) has been developed to provide an objective assessment to the clinical test. Questions persist regarding how this test may be used in the overall vestibular test battery. The purpose of this case report is to describe vestibular test results (vHIT, rotational testing, vestibular evoked myogenic potentials, and balance and gait performance) in an individual with a 100% unilateral caloric weakness who was asymptomatic for dizziness, vertigo or imbalance. Comprehensive assessment was completed to evaluate vestibular function. Caloric irrigations, rotary chair testing, vHIT, and vestibular evoked myogenic potentials were completed. A 100% left-sided unilateral caloric weakness was observed in an asymptomatic individual. vHIT produced normal gain with covert saccades. This case demonstrates the clinical usefulness of vHIT as a diagnostic tool and indicator of vestibular compensation and functional status. American Academy of Audiology.
Keppler, H; Degeest, S; Dhooge, I
2017-11-01
Chronic tinnitus is associated with reduced auditory input, which results in changes in the central auditory system. This study aimed to examine the relationship between tinnitus pitch and parameters of audiometry and distortion product otoacoustic emissions. For audiometry, the parameters represented the edge frequency of hearing loss, the frequency of maximum hearing loss and the frequency range of hearing loss. For distortion product otoacoustic emissions, the parameters were the frequency of lowest distortion product otoacoustic emission amplitudes and the frequency range of reduced distortion product otoacoustic emissions. Sixty-seven patients (45 males, 22 females) with subjective chronic tinnitus, aged 18 to 73 years, were included. No correlation was found between tinnitus pitch and parameters of audiometry and distortion product otoacoustic emissions. However, tinnitus pitch fell mostly within the frequency range of hearing loss. The current study seems to confirm the relationship between tinnitus pitch and the frequency range of hearing loss, thus supporting the homeostatic plasticity model.
Optimal frequency range for medical radar measurements of human heartbeats using body-contact radar.
Brovoll, Sverre; Aardal, Øyvind; Paichard, Yoann; Berger, Tor; Lande, Tor Sverre; Hamran, Svein-Erik
2013-01-01
In this paper the optimal frequency range for heartbeat measurements using body-contact radar is experimentally evaluated. A Body-contact radar senses electromagnetic waves that have penetrated the human body, but the range of frequencies that can be used are limited by the electric properties of the human tissue. The optimal frequency range is an important property needed for the design of body-contact radar systems for heartbeat measurements. In this study heartbeats are measured using three different antennas at discrete frequencies from 0.1 - 10 GHz, and the strength of the received heartbeat signal is calculated. To characterize the antennas, when in contact with the body, two port S-parameters(†) are measured for the antennas using a pork rib as a phantom for the human body. The results shows that frequencies up to 2.5 GHz can be used for heartbeat measurements with body-contact radar.
Nonextensive statistics and skin depth of transverse wave in collisional plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashemzadeh, M., E-mail: hashemzade@gmail.com
Skin depth of transverse wave in a collisional plasma is studied taking into account the nonextensive electron distribution function. Considering the kinetic theory for charge particles and using the Bhatnagar-Gross-Krook collision model, a generalized transverse dielectric permittivity is obtained. The transverse dispersion relation in different frequency ranges is investigated. Obtaining the imaginary part of the wave vector from the dispersion relation, the skin depth for these frequency ranges is also achieved. Profiles of the skin depth show that by increasing the q parameter, the penetration depth decreases. In addition, the skin depth increases by increasing the electron temperature. Finally, itmore » is found that in the high frequency range and high electron temperature, the penetration depth decreases by increasing the collision frequency. In contrast, by increasing the collision frequency in a highly collisional frequency range, the skin depth of transverse wave increases.« less
NASA Astrophysics Data System (ADS)
Aguayo-Rodríguez, Gustavo; Zaldívar-Huerta, Ignacio E.; Rodríguez-Asomoza, Jorge; García-Juárez, Alejandro; Alonso-Rubio, Paul
2010-01-01
The generation, distribution and processing of microwave signals in the optical domain is a topic of research due to many advantages such as low loss, light weight, broadband width, and immunity to electromagnetic interference. In this sense, a novel all-optical microwave photonic filter scheme is proposed and experimentally demonstrated in the frequency range of 0.01-15.0 GHz. A microwave signal generated by optical mixing drives the microwave photonic filter. Basically, photonic filter is composed by a multimode laser diode, an integrated Mach- Zehnder intensity modulator, and 28.3-Km of single-mode standard fiber. Frequency response of the microwave photonic filter depends of the emission spectral characteristics of the multimode laser diode, the physical length of the single-mode standard fiber, and the chromatic dispersion factor associated to this type of fiber. Frequency response of the photonic filter is composed of a low-pass band centered at zero frequency, and several band-pass lobes located periodically on the microwave frequency range. Experimental results are compared by means of numerical simulations in Matlab exhibiting a small deviation in the frequency range of 0.01-5.0 GHz. However, this deviation is more evident when higher frequencies are reached. In this paper, we evaluate the causes of this deviation in the range of 5.0-15.0 GHz analyzing the parameters involved in the frequency response. This analysis permits to improve the performance of the photonic microwave filter to higher frequencies.
Noise and range considerations for close-range radar sensing of life signs underwater.
Hafner, Noah; Lubecke, Victor
2011-01-01
Close-range underwater sensing of motion-based life signs can be performed with low power Doppler radar and ultrasound techniques. Corresponding noise and range performance trade-offs are examined here, with regard to choice of frequency and technology. The frequency range examined includes part of the UHF and microwave spectrum. Underwater detection of motion by radar in freshwater and saltwater are demonstrated. Radar measurements exhibited reduced susceptibility to noise as compared to ultrasound. While higher frequency radar exhibited better signal to noise ratio, propagation was superior for lower frequencies. Radar detection of motion through saltwater was also demonstrated at restricted ranges (1-2 cm) with low power transmission (10 dBm). The results facilitate the establishment of guidelines for optimal choice in technology for the underwater measurement motion-based life signs, with respect to trade offs involving range and noise.
Chivers, Meredith L; Pittini, Richard; Grigoriadis, Sophie; Villegas, Laura; Ross, Lori E
2011-03-01
Previous research on postpartum sexuality has primarily focused on the impact of physical factors on the resumption and frequency of sexual intercourse; fewer studies have focused on the impact of psychological factors on women's sexual functioning. The aim of this study is to assess current sexual functioning and sexual behavior in women with and without symptoms of postpartum depression using validated measures of postpartum depression and sexual functioning. Women attending postpartum appointments were consecutively recruited over a 12-month period and completed questionnaires assessing sexual functioning, current sexual behavior, and mental health. The Female Sexual Function Index (FSFI), the Edinburgh Postnatal Depression Scale (EPDS), and items assessing current sexual behaviors. A total of 77 women returned completed questionnaire packages (mean postpartum weeks: 13, range 3-24). Of these, 57 women (74%) had engaged in sexual activity with a partner in the 4 weeks prior to completing the questionnaire. The mean FSFI score was 23.0 (range 6-34), with 37 women (65%) scoring in the range associated with clinical sexual dysfunction. Women with elevated EPDS scores had significantly lower total FSFI, arousal, orgasm, and satisfaction FSFI subscale scores (all P values <0.005) than nondepressed women, suggesting more problematic sexual functioning. Desire, lubrication, and pain FSFI subscale scores were not significantly associated with depression status. A substantial proportion of women experience sexual problems in the postpartum period; these problems are particularly pronounced among women with symptoms of postpartum depression. Longitudinal research is needed to better understand the relationship between sexual dysfunction and depression among postpartum women, and to identify implications for prevention and treatment of both conditions. © 2010 International Society for Sexual Medicine.
NASA Astrophysics Data System (ADS)
Asano, Shogo; Matsumoto, Hideki
2001-05-01
This paper describes the development process for acceleration sensors used on automobiles and an acceleration evaluation system designed specifically for acceleration at super-low-range frequencies. The features of the newly developed sensor are as follows. 1) Original piezo-bimorph design based on a disc-center-fixed structure achieves pyroeffect cancelling and stabilization of sensor characteristics and enables the detection of the acceleration of 0.0009 G at the super-low-range-frequency of 0.03 Hz. 2) The addition of a self-diagnostic function utilizing the characteristics of piezoceramics enables constant monitoring of sensor failure. The frequency range of acceleration for accurate vehicle motion control is considered to be from DC to about 50 Hz. However, the measurement of acceleration in the super-low-range frequency near DC has been difficult because of mechanical and electrical noise interruption. This has delayed the development of the acceleration sensor for automotive use. We have succeeded in the development of an acceleration evaluation system for super-low-range frequencies from 0.015 Hz to 2 Hz with detection of the acceleration range from 0.0002 G (0.2 gal) to 1 G, as well as the development of a piezoelectric-type acceleration sensor for automotive use.
Pulse homodyne field disturbance sensor
McEwan, Thomas E.
1997-01-01
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudo-randomly modulated so that bursts in the sequence of bursts have a phase which varies. A second range-defining mode transmits two radio frequency bursts, where the time spacing between the bursts defines the maximum range divided by two.
Pulse homodyne field disturbance sensor
McEwan, T.E.
1997-10-28
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudo-randomly modulated so that bursts in the sequence of bursts have a phase which varies. A second range-defining mode transmits two radio frequency bursts, where the time spacing between the bursts defines the maximum range divided by two. 12 figs.
NASA Technical Reports Server (NTRS)
Reddy, C.J.; Deshpande, M.D.
1997-01-01
A hybrid Finite Element Method (FEM)/Method of Moments (MoM) technique in conjunction with the Asymptotic Waveform Evaluation (AWE) technique is applied to obtain radar cross section (RCS) of a cavity-backed aperture in an infinite ground plane over a frequency range. The hybrid FEM/MoM technique when applied to the cavity-backed aperture results in an integro-differential equation with electric field as the unknown variable, the electric field obtained from the solution of the integro-differential equation is expanded in Taylor series. The coefficients of the Taylor series are obtained using the frequency derivatives of the integro-differential equation formed by the hybrid FEM/MoM technique. The series is then matched via the Pade approximation to a rational polynomial, which can be used to extrapolate the electric field over a frequency range. The RCS of the cavity-backed aperture is calculated using the electric field at different frequencies. Numerical results for a rectangular cavity, a circular cavity, and a material filled cavity are presented over a frequency range. Good agreement between AWE and the exact solution over the frequency range is obtained.
Foote, Kenneth G
2012-05-01
Measurement of acoustic backscattering properties of targets requires removal of the range dependence of echoes. This process is called range compensation. For conventional sonars making measurements in the transducer farfield, the compensation removes effects of geometrical spreading and absorption. For parametric sonars consisting of a parametric acoustic transmitter and a conventional-sonar receiver, two additional range dependences require compensation when making measurements in the nonlinearly generated difference-frequency nearfield: an apparently increasing source level and a changing beamwidth. General expressions are derived for range compensation functions in the difference-frequency nearfield of parametric sonars. These are evaluated numerically for a parametric sonar whose difference-frequency band, effectively 1-6 kHz, is being used to observe Atlantic herring (Clupea harengus) in situ. Range compensation functions for this sonar are compared with corresponding functions for conventional sonars for the cases of single and multiple scatterers. Dependences of these range compensation functions on the parametric sonar transducer shape, size, acoustic power density, and hydrography are investigated. Parametric range compensation functions, when applied with calibration data, will enable difference-frequency echoes to be expressed in physical units of volume backscattering, and backscattering spectra, including fish-swimbladder-resonances, to be analyzed.
The frequency range of TMJ sounds.
Widmalm, S E; Williams, W J; Djurdjanovic, D; McKay, D C
2003-04-01
There are conflicting opinions about the frequency range of temporomandibular joint (TMJ) sounds. Some authors claim that the upper limit is about 650 Hz. The aim was to test the hypothesis that TMJ sounds may contain frequencies well above 650 Hz but that significant amounts of their energy are lost if the vibrations are recorded using contact sensors and/or travel far through the head tissues. Time-frequency distributions of 172 TMJ clickings (three subjects) were compared between recordings with one microphone in the ear canal and a skin contact transducer above the clicking joint and between recordings from two microphones, one in each ear canal. The energy peaks of the clickings recorded with a microphone in the ear canal on the clicking side were often well above 650 Hz and always in a significantly higher area (range 117-1922 Hz, P < 0.05 or lower) than in recordings obtained with contact sensors (range 47-375 Hz) or in microphone recordings from the opposite ear canal (range 141-703 Hz). Future studies are required to establish normative frequency range values of TMJ sounds but need methods also capable of recording the high frequency vibrations.
Parametric infrared tunable laser system
NASA Technical Reports Server (NTRS)
Garbuny, M.; Henningsen, T.; Sutter, J. R.
1980-01-01
A parametric tunable infrared laser system was built to serve as transmitter for the remote detection and density measurement of pollutant, poisonous, or trace gases in the atmosphere. The system operates with a YAG:Nd laser oscillator amplifier chain which pumps a parametric tunable frequency converter. The completed system produced pulse energies of up to 30 mJ. The output is tunable from 1.5 to 3.6 micrometers at linewidths of 0.2-0.5 /cm (FWHM), although the limits of the tuning range and the narrower line crystals presently in the parametric converter by samples of the higher quality already demonstrated is expected to improve the system performance further.
NASA Astrophysics Data System (ADS)
Goncharenko, I. A.
1990-04-01
The shift formula method is used to obtain analytic expressions which provide estimates of the influence of nonlinearity on the parameters of fiber waveguide modes. Depending on the sign of the nonlinear susceptibility of the waveguide core, the nonlinearity can improve or impair (right down to complete loss) the waveguiding properties of fibers. The optical power at which a fiber loses its guiding properties is constant far from the cutoff, but rises steeply near the critical cutoff frequency. The nonlinearity can be used to vary the zero dispersion wavelength and the range of single-mode operation of a fiber waveguide.
Endurance testing of a 30-cm Kaufman thruster
NASA Technical Reports Server (NTRS)
Collett, C. R.
1973-01-01
Results of a program to demonstrate lifetime capability of a 30-cm Kaufman ion thruster with a 6000 hour endurance test are described. Included in the program are (1) thruster fabrication, (2) design and construction of a test console containing a transistorized high frequency power processor, and control circuits which provide unattended automatic operation of the thruster, and (3) modification of a vacuum facility to incorporate a frozen mercury collector and permit unattended operation. Four tests ranging in duration from 100 to 1100 hours have been completed. These tests and the resulting thruster modifications are described. The status of the endurance test is also presented.
Topology optimization of two-dimensional elastic wave barriers
NASA Astrophysics Data System (ADS)
Van hoorickx, C.; Sigmund, O.; Schevenels, M.; Lazarov, B. S.; Lombaert, G.
2016-08-01
Topology optimization is a method that optimally distributes material in a given design domain. In this paper, topology optimization is used to design two-dimensional wave barriers embedded in an elastic halfspace. First, harmonic vibration sources are considered, and stiffened material is inserted into a design domain situated between the source and the receiver to minimize wave transmission. At low frequencies, the stiffened material reflects and guides waves away from the surface. At high frequencies, destructive interference is obtained that leads to high values of the insertion loss. To handle harmonic sources at a frequency in a given range, a uniform reduction of the response over a frequency range is pursued. The minimal insertion loss over the frequency range of interest is maximized. The resulting design contains features at depth leading to a reduction of the insertion loss at the lowest frequencies and features close to the surface leading to a reduction at the highest frequencies. For broadband sources, the average insertion loss in a frequency range is optimized. This leads to designs that especially reduce the response at high frequencies. The designs optimized for the frequency averaged insertion loss are found to be sensitive to geometric imperfections. In order to obtain a robust design, a worst case approach is followed.
ERIC Educational Resources Information Center
Grover, Lawrence M.; Kim, Eunyoung; Cooke, Jennifer D.; Holmes, William R.
2009-01-01
Long-term potentiation (LTP) is typically studied using either continuous high-frequency stimulation or theta burst stimulation. Previous studies emphasized the physiological relevance of theta frequency; however, synchronized hippocampal activity occurs over a broader frequency range. We therefore tested burst stimulation at intervals from 100…
Catoni, Nicholas
2015-01-01
Abstract High-frequency oscillations (HFOs) are an intriguing potential biomarker for epilepsy, typically categorized according to peak frequency as either ripples (100–250 Hz) or fast ripples (>250 Hz). In the hippocampus, fast ripples were originally thought to be more specific to epileptic tissue, but it is still very difficult to distinguish which HFOs are caused by normal versus pathological brain activity. In this study, we use a computational model of hippocampus to investigate possible network mechanisms underpinning normal ripples, pathological ripples, and fast ripples. Our results unify several prior findings regarding HFO mechanisms, and also make several new predictions regarding abnormal HFOs. We show that HFOs are generic, emergent phenomena whose characteristics reflect a wide range of connectivity and network input. Although produced by different mechanisms, both normal and abnormal HFOs generate similar ripple frequencies, underscoring that peak frequency is unable to distinguish the two. Abnormal ripples are generic phenomena that arise when input to pyramidal cells overcomes network inhibition, resulting in high-frequency, uncoordinated firing. In addition, fast ripples transiently and sporadically arise from the precise conditions that produce abnormal ripples. Lastly, we show that such abnormal conditions do not require any specific network structure to produce coherent HFOs, as even completely asynchronous activity is capable of producing abnormal ripples and fast ripples in this manner. These results provide a generic, network-based explanation for the link between pathological ripples and fast ripples, and a unifying description for the entire spectrum from normal ripples to pathological fast ripples. PMID:26146658
Spatial Frequency Discrimination: Effects of Age, Reward, and Practice
Peters, Judith Carolien
2017-01-01
Social interaction starts with perception of the world around you. This study investigated two fundamental issues regarding the development of discrimination of higher spatial frequencies, which are important building blocks of perception. Firstly, it mapped the typical developmental trajectory of higher spatial frequency discrimination. Secondly, it developed and validated a novel design that could be applied to improve atypically developed vision. Specifically, this study examined the effect of age and reward on task performance, practice effects, and motivation (i.e., number of trials completed) in a higher spatial frequency (reference frequency: 6 cycles per degree) discrimination task. We measured discrimination thresholds in children aged between 7 to 12 years and adults (N = 135). Reward was manipulated by presenting either positive reinforcement or punishment. Results showed a decrease in discrimination thresholds with age, thus revealing that higher spatial frequency discrimination continues to develop after 12 years of age. This development continues longer than previously shown for discrimination of lower spatial frequencies. Moreover, thresholds decreased during the run, indicating that discrimination abilities improved. Reward did not affect performance or improvement. However, in an additional group of 5–6 year-olds (N = 28) punishments resulted in the completion of fewer trials compared to reinforcements. In both reward conditions children aged 5–6 years completed only a fourth or half of the run (64 to 128 out of 254 trials) and were not motivated to continue. The design thus needs further adaptation before it can be applied to this age group. Children aged 7–12 years and adults completed the run, suggesting that the design is successful and motivating for children aged 7–12 years. This study thus presents developmental differences in higher spatial frequency discrimination thresholds. Furthermore, it presents a design that can be used in future developmental studies that require multiple stimulus presentations such as visual perceptual learning. PMID:28135272
Spatial Frequency Discrimination: Effects of Age, Reward, and Practice.
van den Boomen, Carlijn; Peters, Judith Carolien
2017-01-01
Social interaction starts with perception of the world around you. This study investigated two fundamental issues regarding the development of discrimination of higher spatial frequencies, which are important building blocks of perception. Firstly, it mapped the typical developmental trajectory of higher spatial frequency discrimination. Secondly, it developed and validated a novel design that could be applied to improve atypically developed vision. Specifically, this study examined the effect of age and reward on task performance, practice effects, and motivation (i.e., number of trials completed) in a higher spatial frequency (reference frequency: 6 cycles per degree) discrimination task. We measured discrimination thresholds in children aged between 7 to 12 years and adults (N = 135). Reward was manipulated by presenting either positive reinforcement or punishment. Results showed a decrease in discrimination thresholds with age, thus revealing that higher spatial frequency discrimination continues to develop after 12 years of age. This development continues longer than previously shown for discrimination of lower spatial frequencies. Moreover, thresholds decreased during the run, indicating that discrimination abilities improved. Reward did not affect performance or improvement. However, in an additional group of 5-6 year-olds (N = 28) punishments resulted in the completion of fewer trials compared to reinforcements. In both reward conditions children aged 5-6 years completed only a fourth or half of the run (64 to 128 out of 254 trials) and were not motivated to continue. The design thus needs further adaptation before it can be applied to this age group. Children aged 7-12 years and adults completed the run, suggesting that the design is successful and motivating for children aged 7-12 years. This study thus presents developmental differences in higher spatial frequency discrimination thresholds. Furthermore, it presents a design that can be used in future developmental studies that require multiple stimulus presentations such as visual perceptual learning.
NASA Astrophysics Data System (ADS)
Tsyba, E.; Kaufman, M.
2015-08-01
Preparatory works for resuming operational calculations of the Earth rotation parameters based on the results of satellite laser ranging data processing (LAGEOS 1, LAGEOS 2) are to be completed in the Main Metrology Centre Of The State Time And Frequency Service (VNIIFTRI) in 2014. For this purpose BERNESE 5.2 software (Dach & Walser, 2014) was chosen as a base software which has been used for many years in the Main Metrological Centre of the State Time and Frequency Service to process phase observations of GLONASS and GPS satellites. Although in the BERNESE 5.2 software announced presentation the possibility of the SLR data processing is declared, it has not been fully implemented. In particular there is no such an essential element as corrective action (as input or resulting parameters) in the local time scale ("time bias"), etc. Therefore, additional program blocks have been developed and integrated into the BERNESE 5.2 software environment. The program blocks are written in Perl and Matlab program languages and can be used both for Windows and Linux, 32-bit and 64-bit platforms.
NASA Astrophysics Data System (ADS)
Ruggiero, Michael T.; Zhang, Wei; Bond, Andrew D.; Mittleman, Daniel M.; Zeitler, J. Axel
2018-05-01
The low-frequency motions of molecules in the condensed phase have been shown to be vital to a large number of physical properties and processes. However, in the case of disordered systems, it is often difficult to elucidate the atomic-level details surrounding these phenomena. In this work, we have performed an extensive experimental and computational study on the molecular solid camphor, which exhibits a rich and complex structure-dynamics relationship, and undergoes an order-disorder transition near ambient conditions. The combination of x-ray diffraction, variable temperature and pressure terahertz time-domain spectroscopy, ab initio molecular dynamics, and periodic density functional theory calculations enables a complete picture of the phase transition to be obtained, inclusive of mechanistic, structural, and thermodynamic phenomena. Additionally, the low-frequency vibrations of a disordered solid are characterized for the first time with atomic-level precision, uncovering a clear link between such motions and the phase transformation. Overall, this combination of methods allows for significant details to be obtained for disordered solids and the associated transformations, providing a framework that can be directly applied for a wide range of similar systems.
Valerio, Laura; North, Ace; Collins, C. Matilda; Mumford, John D.; Facchinelli, Luca; Spaccapelo, Roberta; Benedict, Mark Q.
2016-01-01
The persistence of transgenes in the environment is a consideration in risk assessments of transgenic organisms. Combining mathematical models that predict the frequency of transgenes and experimental demonstrations can validate the model predictions, or can detect significant biological deviations that were neither apparent nor included as model parameters. In order to assess the correlation between predictions and observations, models were constructed to estimate the frequency of a transgene causing male sexual sterility in simulated populations of a malaria mosquito Anopheles gambiae that were seeded with transgenic females at various proportions. Concurrently, overlapping-generation laboratory populations similar to those being modeled were initialized with various starting transgene proportions, and the subsequent proportions of transgenic individuals in populations were determined weekly until the transgene disappeared. The specific transgene being tested contained a homing endonuclease gene expressed in testes, I-PpoI, that cleaves the ribosomal DNA and results in complete male sexual sterility with no effect on female fertility. The transgene was observed to disappear more rapidly than the model predicted in all cases. The period before ovipositions that contained no transgenic progeny ranged from as little as three weeks after cage initiation to as long as 11 weeks. PMID:27669312
Guided waves and ultrasonic characterization of three-dimensional composites
NASA Astrophysics Data System (ADS)
Leymarie, Nicolas; Baste, Stéphane
2000-05-01
Ultrasonic NDE of anisotropic media appears nowadays as one of the best experimental approaches in studying mechanical properties. A complete identification of stiffness tensor can be performed with phase velocity measurements of obliquely incidence ultrasonic bulk waves from water onto a plate. The medium considered, however, has to be homogeneous with respect to wavelength used. In the case of 3D-composites, textures scales may reach one millimeter and their cut-off frequency is less than MHz. The dispersion curves observed in the considered range of frequencies are often very close and sometimes may be overlapped. Experimental studies show complex signals, which are due to a combination of both bulk and guided waves. Wave-speed measurements of the bulk wave and its detection become unreliable with classical techniques of signal processing (simple time or spectral analysis). Moreover, even if the coupled time-frequency analysis with wavelet transforms allows a better interpretation of the signal, the time delay estimation for the bulk wave and so the characterization of the material remains uncertain. To understand blended signals more accurately, different analytical and numerical models are proposed to show the advantages and disadvantages of methods used in NDE.
Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.
Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E
2014-02-01
Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.
NASA Astrophysics Data System (ADS)
Aasi, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V.; Affeldt, C.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Ain, A.; Ajith, P.; Alemic, A.; Allen, B.; Allocca, A.; Amariutei, D.; Anderson, S. B.; Anderson, W. G.; Arai, K.; Araya, M. C.; Arceneaux, C.; Areeda, J. S.; Ashton, G.; Ast, S.; Aston, S. M.; Astone, P.; Aufmuth, P.; Aulbert, C.; Aylott, B. E.; Babak, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Barayoga, J. C.; Barbet, M.; Barclay, S.; Barish, B. C.; Barker, D.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Bartlett, J.; Barton, M. A.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bauer, Th. S.; Baune, C.; Bavigadda, V.; Behnke, B.; Bejger, M.; Belczynski, C.; Bell, A. S.; Bell, C.; Benacquista, M.; Bergman, J.; Bergmann, G.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Birch, J.; Biscans, S.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackburn, L.; Blair, C. D.; Blair, D.; Bloemen, S.; Bock, O.; Bodiya, T. P.; Boer, M.; Bogaert, G.; Bojtos, P.; Bond, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Bork, R.; Born, M.; Boschi, V.; Bose, Sukanta; Bradaschia, C.; Brady, P. R.; Braginsky, V. B.; Branchesi, M.; Brau, J. E.; Briant, T.; Bridges, D. O.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brown, N. M.; Buchman, S.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Cadonati, L.; Cagnoli, G.; Calderón Bustillo, J.; Calloni, E.; Camp, J. B.; Cannon, K. C.; Cao, J.; Capano, C. D.; Carbognani, F.; Caride, S.; Caudill, S.; Cavaglià, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C.; Cesarini, E.; Chakraborty, R.; Chalermsongsak, T.; Chamberlin, S. J.; Chao, S.; Charlton, P.; Chassande-Mottin, E.; Chen, Y.; Chincarini, A.; Chiummo, A.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, S.; Chung, S.; Ciani, G.; Clara, F.; Clark, J. A.; Cleva, F.; Coccia, E.; Cohadon, P.-F.; Colla, A.; Collette, C.; Colombini, M.; Cominsky, L.; Constancio, M.; Conte, A.; Cook, D.; Corbitt, T. R.; Cornish, N.; Corsi, A.; Costa, C. A.; Coughlin, M. W.; Coulon, J.-P.; Countryman, S.; Couvares, P.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Craig, K.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cumming, A.; Cunningham, L.; Cuoco, E.; Cutler, C.; Dahl, K.; Canton, T. Dal; Damjanic, M.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dartez, L.; Dattilo, V.; Dave, I.; Daveloza, H.; Davier, M.; Davies, G. S.; Daw, E. J.; Day, R.; DeBra, D.; Debreczeni, G.; Degallaix, J.; De Laurentis, M.; Deléglise, S.; Del Pozzo, W.; Denker, T.; Dent, T.; Dereli, H.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; DeSalvo, R.; Dhurandhar, S.; Díaz, M.; Di Fiore, L.; Di Lieto, A.; Di Palma, I.; Di Virgilio, A.; Dojcinoski, G.; Dolique, V.; Dominguez, E.; Donovan, F.; Dooley, K. L.; Doravari, S.; Douglas, R.; Downes, T. P.; Drago, M.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dwyer, S.; Eberle, T.; Edo, T.; Edwards, M.; Edwards, M.; Effler, A.; Eggenstein, H.-B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Essick, R.; Etzel, T.; Evans, M.; Evans, T.; Factourovich, M.; Fafone, V.; Fairhurst, S.; Fan, X.; Fang, Q.; Farinon, S.; Farr, B.; Farr, W. M.; Favata, M.; Fays, M.; Fehrmann, H.; Fejer, M. M.; Feldbaum, D.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Fiori, I.; Fisher, R. P.; Flaminio, R.; Fournier, J.-D.; Franco, S.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Fricke, T. T.; Fritschel, P.; Frolov, V. V.; Fuentes-Tapia, S.; Fulda, P.; Fyffe, M.; Gair, J. R.; Gammaitoni, L.; Gaonkar, S.; Garufi, F.; Gatto, A.; Gehrels, N.; Gemme, G.; Gendre, B.; Genin, E.; Gennai, A.; Gergely, L. Á.; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gleason, J.; Goetz, E.; Goetz, R.; Gondan, L.; González, G.; Gordon, N.; Gorodetsky, M. L.; Gossan, S.; Goßler, S.; Gouaty, R.; Gräf, C.; Graff, P. B.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Greenhalgh, R. J. S.; Gretarsson, A. M.; Groot, P.; Grote, H.; Grunewald, S.; Guidi, G. M.; Guido, C. J.; Guo, X.; Gushwa, K.; Gustafson, E. K.; Gustafson, R.; Hacker, J.; Hall, E. D.; Hammond, G.; Hanke, M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M.; Hartman, M. T.; Haster, C.-J.; Haughian, K.; Hee, S.; Heidmann, A.; Heintze, M.; Heinzel, G.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Heptonstall, A. W.; Heurs, M.; Hewitson, M.; Hild, S.; Hoak, D.; Hodge, K. A.; Hofman, D.; Hollitt, S. E.; Holt, K.; Hopkins, P.; Hosken, D. J.; Hough, J.; Houston, E.; Howell, E. J.; Hu, Y. M.; Huerta, E.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh, M.; Huynh-Dinh, T.; Idrisy, A.; Indik, N.; Ingram, D. R.; Inta, R.; Islas, G.; Isler, J. C.; Isogai, T.; Iyer, B. R.; Izumi, K.; Jacobson, M.; Jang, H.; Jaranowski, P.; Jawahar, S.; Ji, Y.; Jiménez-Forteza, F.; Johnson, W. W.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Haris, K.; Kalogera, V.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kasprzack, M.; Katsavounidis, E.; Katzman, W.; Kaufer, H.; Kaufer, S.; Kaur, T.; Kawabe, K.; Kawazoe, F.; Kéfélian, F.; Keiser, G. M.; Keitel, D.; Kelley, D. B.; Kells, W.; Keppel, D. G.; Key, J. S.; Khalaidovski, A.; Khalili, F. Y.; Khazanov, E. A.; Kim, C.; Kim, K.; Kim, N. G.; Kim, N.; Kim, Y.-M.; King, E. J.; King, P. J.; Kinzel, D. L.; Kissel, J. S.; Klimenko, S.; Kline, J.; Koehlenbeck, S.; Kokeyama, K.; Kondrashov, V.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kringel, V.; Krishnan, B.; Królak, A.; Krueger, C.; Kuehn, G.; Kumar, A.; Kumar, P.; Kuo, L.; Kutynia, A.; Landry, M.; Lantz, B.; Larson, S.; Lasky, P. D.; Lazzarini, A.; Lazzaro, C.; Lazzaro, C.; Le, J.; Leaci, P.; Leavey, S.; Lebigot, E.; Lebigot, E. O.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Leonardi, M.; Leong, J. R.; Leroy, N.; Letendre, N.; Levin, Y.; Levine, B.; Lewis, J.; Li, T. G. F.; Libbrecht, K.; Libson, A.; Lin, A. C.; Littenberg, T. B.; Lockerbie, N. A.; Lockett, V.; Logue, J.; Lombardi, A. L.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J.; Lubinski, M. J.; Lück, H.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macarthur, J.; MacDonald, T.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Magaña-Sandoval, F.; Magee, R.; Mageswaran, M.; Maglione, C.; Mailand, K.; Majorana, E.; Maksimovic, I.; Malvezzi, V.; Man, N.; Mandel, I.; Mandic, V.; Mangano, V.; Mangano, V.; Mansell, G. L.; Mantovani, M.; Marchesoni, F.; Marion, F.; Márka, S.; Márka, Z.; Markosyan, A.; Maros, E.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D.; Marx, J. N.; Mason, K.; Masserot, A.; Massinger, T. J.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; Mazzolo, G.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McGuire, S. C.; McIntyre, G.; McIver, J.; McLin, K.; McWilliams, S.; Meacher, D.; Meadors, G. D.; Meidam, J.; Meinders, M.; Melatos, A.; Mendell, G.; Mercer, R. A.; Meshkov, S.; Messenger, C.; Meyers, P. M.; Mezzani, F.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A.; Miller, J.; Millhouse, M.; Minenkov, Y.; Ming, J.; Mirshekari, S.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moe, B.; Moggi, A.; Mohan, M.; Mohanty, S. D.; Mohapatra, S. R. P.; Moore, B.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mossavi, K.; Mours, B.; Mow-Lowry, C. M.; Mueller, C. L.; Mueller, G.; Mukherjee, S.; Mullavey, A.; Munch, J.; Murphy, D.; Murray, P. G.; Mytidis, A.; Nagy, M. F.; Nardecchia, I.; Nash, T.; Naticchioni, L.; Nayak, R. K.; Necula, V.; Nedkova, K.; Nelemans, G.; Neri, I.; Neri, M.; Newton, G.; Nguyen, T.; Nielsen, A. B.; Nissanke, S.; Nitz, A. H.; Nocera, F.; Nolting, D.; Normandin, M. E. N.; Nuttall, L. K.; Ochsner, E.; O'Dell, J.; Oelker, E.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Oppermann, P.; Oram, R.; O'Reilly, B.; Ortega, W.; O'Shaughnessy, R.; Osthelder, C.; Ottaway, D. J.; Ottens, R. S.; Overmier, H.; Owen, B. J.; Padilla, C.; Pai, A.; Pai, S.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Papa, M. A.; Paris, H.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patrick, Z.; Pedraza, M.; Pekowsky, L.; Pele, A.; Penn, S.; Perreca, A.; Phelps, M.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pitkin, M.; Poeld, J.; Poggiani, R.; Post, A.; Poteomkin, A.; Powell, J.; Prasad, J.; Predoi, V.; Premachandra, S.; Prestegard, T.; Price, L. R.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L.; Puncken, O.; Punturo, M.; Puppo, P.; Pürrer, M.; Qin, J.; Quetschke, V.; Quintero, E.; Quiroga, G.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Rácz, I.; Radkins, H.; Raffai, P.; Raja, S.; Rajalakshmi, G.; Rakhmanov, M.; Ramirez, K.; Rapagnani, P.; Raymond, V.; Razzano, M.; Re, V.; Reed, C. M.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Reula, O.; Ricci, F.; Riles, K.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V.; Romano, R.; Romanov, G.; Romie, J. H.; Rosińska, D.; Rowan, S.; Rüdiger, A.; Ruggi, P.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Saleem, M.; Salemi, F.; Sammut, L.; Sandberg, V.; Sanders, J. R.; Sannibale, V.; Santiago-Prieto, I.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Savage, R.; Sawadsky, A.; Scheuer, J.; Schilling, R.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schreiber, E.; Schuette, D.; Schutz, B. F.; Scott, J.; Scott, S. M.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Serafinelli, R.; Sergeev, A.; Serna, G.; Sevigny, A.; Shaddock, D. A.; Shah, S.; Shahriar, M. S.; Shaltev, M.; Shao, Z.; Shapiro, B.; Shawhan, P.; Shoemaker, D. H.; Sidery, T. L.; Siellez, K.; Siemens, X.; Sigg, D.; Silva, A. D.; Simakov, D.; Singer, A.; Singer, L.; Singh, R.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, J. R.; Smith, M. R.; Smith, R. J. E.; Smith-Lefebvre, N. D.; Son, E. J.; Sorazu, B.; Souradeep, T.; Staley, A.; Stebbins, J.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stephens, B. C.; Steplewski, S.; Stevenson, S.; Stone, R.; Strain, K. A.; Straniero, N.; Strigin, S.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sutton, P. J.; Swinkels, B.; Szczepanczyk, M.; Szeifert, G.; Tacca, M.; Talukder, D.; Tanner, D. B.; Tápai, M.; Tarabrin, S. P.; Taracchini, A.; Taylor, R.; Tellez, G.; Theeg, T.; Thirugnanasambandam, M. P.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, V.; Tomlinson, C.; Tonelli, M.; Torres, C. V.; Torrie, C. I.; Travasso, F.; Traylor, G.; Tse, M.; Tshilumba, D.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Vajente, G.; Valdes, G.; Vallisneri, M.; van Bakel, N.; van Beuzekom, M.; van den Brand, J. F. J.; van den Broeck, C.; van der Sluys, M. V.; van Heijningen, J.; van Veggel, A. A.; Vass, S.; Vasúth, M.; Vaulin, R.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Verkindt, D.; Vetrano, F.; Viceré, A.; Vincent-Finley, R.; Vinet, J.-Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vousden, W. D.; Vyatchanin, S. P.; Wade, A. R.; Wade, L.; Wade, M.; Walker, M.; Wallace, L.; Walsh, S.; Wang, H.; Wang, M.; Wang, X.; Ward, R. L.; Warner, J.; Was, M.; Weaver, B.; Wei, L.-W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Welborn, T.; Wen, L.; Wessels, P.; Westphal, T.; Wette, K.; Whelan, J. T.; White, D. J.; Whiting, B. F.; Wilkinson, C.; Williams, L.; Williams, R.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Worden, J.; Xie, S.; Yablon, J.; Yakushin, I.; Yam, W.; Yamamoto, H.; Yancey, C. C.; Yang, Q.; Yvert, M.; ZadroŻny, A.; Zanolin, M.; Zendri, J.-P.; Zhang, Fan; Zhang, L.; Zhang, M.; Zhang, Y.; Zhao, C.; Zhou, M.; Zhu, X. J.; Zucker, M. E.; Zuraw, S.; Zweizig, J.; LIGO Scientific Collaboration; Virgo Collaboration
2015-01-01
In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.
NASA Technical Reports Server (NTRS)
Aasi, J.; Abbott, B. P.; Abbott, R.; Abbott, T.; Abernathy, M. R.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Adams, T.;
2015-01-01
In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed both assuming polarization parameters are completely unknown and that they are known with some uncertainty, as derived from X-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of two below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.
NASA Technical Reports Server (NTRS)
Stringer, Mary T.; Cowen, Brandon; Hoffler, Keith D.; Couch, Jesse C.; Ogburn, Marilyn E.; Diebler, Corey G.
2013-01-01
The NASA Langley Research Center Cockpit Motion Facility (CMF) was used to conduct a piloted simulation assessment of the impact of flexible structures on flying qualities. The CMF was used because of its relatively high bandwidth, six degree-of-freedom motion capability. Previous studies assessed and attempted to mitigate the effects of multiple dynamic aeroservoelastic modes (DASE). Those results indicated problems existed, but the specific cause and effect was difficult to ascertain. The goal of this study was to identify specific DASE frequencies, damping ratios, and gains that cause degradation in handling qualities. A generic aircraft simulation was developed and designed to have Cooper-Harper Level 1 handling qualities when flown without DASE models. A test matrix of thirty-six DASE modes was implemented. The modes had frequencies ranging from 1 to 3.5 Hz and were applied to each axis independently. Each mode consisted of a single axis, frequency, damping, and gain, and was evaluated individually by six subject pilots with test pilot backgrounds. Analysis completed to date suggests that a number of the DASE models evaluated degrade the handling qualities of this class of aircraft to an uncontrollable condition.
NASA Astrophysics Data System (ADS)
Alamri, Sagr; Li, Bing; Tan, K. T.
2018-03-01
Dissipative elastic metamaterials have attracted increased attention in recent times. This paper presents the development of a dissipative elastic metamaterial with multiple Maxwell-type resonators for stress wave attenuation. The mechanism of the dissipation effect on the vibration characteristics is systematically investigated by mass-spring-damper models with single and dual resonators. Based on the parameter optimization, it is revealed that a broadband wave attenuation region (stopping band) can be obtained by properly utilizing interactions from resonant motions and viscoelastic effects of the Maxwell-type oscillators. The relevant numerical verifications are conducted for various cases, and excellent agreement between the numerical and theoretical frequency response functions is shown. The design of this dissipative metamaterial system is further applied for dynamic load mitigation and blast wave attenuation. Moreover, the transient response in the continuum model is designed and analyzed for more robust design. By virtue of the bandgap merging effect induced by the Maxwell-type damper, the transient blast wave can be almost completely suppressed in the low frequency range. A significantly improved performance of the proposed dissipative metamaterials for stress wave mitigation is verified in both time and frequency domains.
Ruggiero, Michael T; Zhang, Wei; Bond, Andrew D; Mittleman, Daniel M; Zeitler, J Axel
2018-05-11
The low-frequency motions of molecules in the condensed phase have been shown to be vital to a large number of physical properties and processes. However, in the case of disordered systems, it is often difficult to elucidate the atomic-level details surrounding these phenomena. In this work, we have performed an extensive experimental and computational study on the molecular solid camphor, which exhibits a rich and complex structure-dynamics relationship, and undergoes an order-disorder transition near ambient conditions. The combination of x-ray diffraction, variable temperature and pressure terahertz time-domain spectroscopy, ab initio molecular dynamics, and periodic density functional theory calculations enables a complete picture of the phase transition to be obtained, inclusive of mechanistic, structural, and thermodynamic phenomena. Additionally, the low-frequency vibrations of a disordered solid are characterized for the first time with atomic-level precision, uncovering a clear link between such motions and the phase transformation. Overall, this combination of methods allows for significant details to be obtained for disordered solids and the associated transformations, providing a framework that can be directly applied for a wide range of similar systems.
Characterization of Acoustic Streaming Beyond 100 MHz
NASA Astrophysics Data System (ADS)
Eisener, J.; Lippert, A.; Nowak, T.; Cairós, C.; Reuter, F.; Mettin, R.
The aim of this study is to investigate acoustic streaming in water at very high ultrasonic frequencies, namely beyond 100 MHz. At such high frequencies, the dissipation length of acoustic waves shrinks considerably, and the acoustic streaming transforms from the well-known Eckart type into a Stuart-Lighthill type: While Eckart streaming is driven by a small momentum transfer along the path of a weakly damped travelling sound wave, Stuart-Lighthill streaming is generated by rather local and strong momentum transfer of a highly damped and therefore rapidly decaying wave. Then the inertia of the induced flow cannot be neglected anymore, and a potentially turbulent jet flow emerges. Here we report on streaming velocity measurements for the case where the sound is completely absorbed within a region much smaller than the generated jet. In contrast to previous work in this frequency range, where mainly surface acoustic wave transducers have been employed, we use piston-type transducers that emit vertically to the transducer surface. The acoustic streaming effects are characterized by ink front tracking and particle tracking velocimetry, and by numerical studies. The results show narrow high-speed jet flows that extend much farther into the liquid than the acoustic field. Velocities of several m/s are observed.
Guided Z mode propagation observed in the OEDIPUS A tethered rocket experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, H.G.
1991-10-01
The tethered sounding rocket payload OEDIPUS A conducted bistatic propagation experiments on plasma waves in the auroral ionosphere. Synchronized sweeps of the frequency range 0-5 MHz by the 2-W transmitter high-frequency exciter (HEX) on the upper end of the tether and its associated receiver for exciter (REX) on the lower end have produced signatures of quasi-electrostatic waves guided along field-aligned depletions of ambient density. The propagation is in the slow Z mode, between the plasma frequency f{sub p} and the upper hybrid resonance frequency f{sub uhr} when f{sub p} is greater than the cyclotron frequency. The mode identification is basedmore » on payload measurements of f{sub p}. These waves have signal delays of about 1 ms. The delays are much greater than expected for free-space propagation over the transmitter-receiver separation distance which varies up to 960 m during the flight. The transmitted pulses typically appear inside a frequency bandwidth of about 100 kHz just above the plasma frequency, but occasionally occupy most of the available bandwidth, {approx equal}300 kHz, between f{sub p} and f{sub uhr}. The observed delays and the stretching by a factor of 3 of the transmitted 300-{mu}s pulses are accounted for with two-dimensional ray tracing using a complete electromagnetic solution of the hot plasma dispersion relation. Delayed Z mode pulses appear in about 20% of the ionograms. Given the weakness of the HEX transmitter and the abundance of examples obtained during the flight, guiding of natural Z mode emissions in the auroral ionosphere may be efficient and widespread.« less
Highly sensitive atomic based MW interferometry.
Shylla, Dangka; Nyakang'o, Elijah Ogaro; Pandey, Kanhaiya
2018-06-06
We theoretically study a scheme to develop an atomic based micro-wave (MW) interferometry using the Rydberg states in Rb. Unlike the traditional MW interferometry, this scheme is not based upon the electrical circuits, hence the sensitivity of the phase and the amplitude/strength of the MW field is not limited by the Nyquist thermal noise. Further, this system has great advantage due to its much higher frequency range in comparision to the electrical circuit, ranging from radio frequency (RF), MW to terahertz regime. In addition, this is two orders of magnitude more sensitive to field strength as compared to the prior demonstrations on the MW electrometry using the Rydberg atomic states. Further, previously studied atomic systems are only sensitive to the field strength but not to the phase and hence this scheme provides a great opportunity to characterize the MW completely including the propagation direction and the wavefront. The atomic based MW interferometry is based upon a six-level loopy ladder system involving the Rydberg states in which two sub-systems interfere constructively or destructively depending upon the phase between the MW electric fields closing the loop. This work opens up a new field i.e. atomic based MW interferometry replacing the conventional electrical circuit in much superior fashion.
Space Weather Action Plan Solar Radio Burst Phase 1 Benchmarks and the Steps to Phase 2
NASA Astrophysics Data System (ADS)
Biesecker, D. A.; White, S. M.; Gopalswamy, N.; Black, C.; Love, J. J.; Pierson, J.
2017-12-01
Solar radio bursts, when at the right frequency and when strong enough, can interfere with radar, communication, and tracking signals. In severe cases, radio bursts can inhibit the successful use of radio communications and disrupt a wide range of systems that are reliant on Position, Navigation, and Timing services on timescales ranging from minutes to hours across wide areas on the dayside of Earth. The White House's Space Weather Action Plan asked for solar radio burst intensity benchmarks for an event occurrence frequency of 1 in 100 years and also a theoretical maximum intensity benchmark. The benchmark team has developed preliminary (phase 1) benchmarks for the VHF (30-300 MHz), UHF (300-3000 MHz), GPS (1176-1602 MHz), F10.7 (2800 MHz), and Microwave (4000-20000) bands. The preliminary benchmarks were derived based on previously published work. Limitations in the published work will be addressed in phase 2 of the benchmark process. In addition, deriving theoretical maxima requires additional work, where it is even possible to, in order to meet the Action Plan objectives. In this presentation, we will present the phase 1 benchmarks, the basis used to derive them, and the limitations of that work. We will also discuss the work that needs to be done to complete the phase 2 benchmarks.
NASA Astrophysics Data System (ADS)
Modegi, Toshio
We are developing audio watermarking techniques which enable extraction of embedded data by cell phones. For that we have to embed data onto frequency ranges, where our auditory response is prominent, therefore data embedding will cause much auditory noises. Previously we have proposed applying a two-channel stereo play-back feature, where noises generated by a data embedded left-channel signal will be reduced by the other right-channel signal. However, this proposal has practical problems of restricting extracting terminal location. In this paper, we propose synthesizing the noise reducing right-channel signal with the left-signal and reduces noises completely by generating an auditory stream segregation phenomenon to users. This newly proposed makes the noise reducing right-channel signal unnecessary and supports monaural play-back operations. Moreover, we propose a wide-band embedding method causing dual auditory stream segregation phenomena, which enables data embedding on whole public phone frequency ranges and stable extractions with 3-G mobile phones. From these proposals, extraction precisions become higher than those by the previously proposed method whereas the quality damages of embedded signals become smaller. In this paper we present an abstract of our newly proposed method and experimental results comparing with those by the previously proposed method.
Developing Benchmarks for Solar Radio Bursts
NASA Astrophysics Data System (ADS)
Biesecker, D. A.; White, S. M.; Gopalswamy, N.; Black, C.; Domm, P.; Love, J. J.; Pierson, J.
2016-12-01
Solar radio bursts can interfere with radar, communication, and tracking signals. In severe cases, radio bursts can inhibit the successful use of radio communications and disrupt a wide range of systems that are reliant on Position, Navigation, and Timing services on timescales ranging from minutes to hours across wide areas on the dayside of Earth. The White House's Space Weather Action Plan has asked for solar radio burst intensity benchmarks for an event occurrence frequency of 1 in 100 years and also a theoretical maximum intensity benchmark. The solar radio benchmark team was also asked to define the wavelength/frequency bands of interest. The benchmark team developed preliminary (phase 1) benchmarks for the VHF (30-300 MHz), UHF (300-3000 MHz), GPS (1176-1602 MHz), F10.7 (2800 MHz), and Microwave (4000-20000) bands. The preliminary benchmarks were derived based on previously published work. Limitations in the published work will be addressed in phase 2 of the benchmark process. In addition, deriving theoretical maxima requires additional work, where it is even possible to, in order to meet the Action Plan objectives. In this presentation, we will present the phase 1 benchmarks and the basis used to derive them. We will also present the work that needs to be done in order to complete the final, or phase 2 benchmarks.
NASA Astrophysics Data System (ADS)
Xu, Ling; Tan, Yidong; Zhang, Shulian
2018-03-01
The accuracy of the existing laser feedback interferometry for measuring the remote target is limited to several microns due to environmental disturbances. A novel approach is presented in this paper based on the double-beam frequency-shift feedback of the laser, which can completely eliminate the dead path errors and measure the displacement or vibration with accuracy at nanometer scale even at a far measurement distance. The two beams emitted from one Nd:YVO4 crystal are incident on the measurement target and its adjacent reference surface, respectively. The reference surface could be taken from the nearby stationary object, without the need to put a reference mirror. The feedback paths and shift frequencies of the two beams are the same, so the air disturbances and the thermal effects in the way could be fully compensated. Under common room conditions, the displacement of a steel block at a distance of 10 m is measured, which proved that the system's stability is ±12 nm in 100 s and ±50 nm in 1000 s, the short-term resolution is better than 3 nm, and the linearity within the 300 mm range is 5 × 10-6 and within the 100 μm range is 1 × 10-4.
Solar observations with the prototype of the Brazilian Decimetric Array
NASA Astrophysics Data System (ADS)
Sawant, H. S.; Ramesh, R.; Faria, C.; Cecatto, J. R.; Fernandes, F. C. R.; Madsen, F. H. R.; Subramanian, K. R.; Sundararajan, M. S.
The prototype of the Brazilian Decimetric Array BDA consists of 5 element alt-az mounted parabolic mesh type dishes of 4-meter diameter having base lines up to 220 meters in the E--W direction The array was put into regular operation at Cachoeira Paulista Brazil longitude 45 r 00 20 W and latitude 22 r 41 19 S This array operates in the frequency range of 1 2 -- 1 7 GHz Solar observations are carried at sim 1 4 GHz in transit and tracking modes Spatial fine structures superimposed on the one dimensional brightness map of the sun associated with active regions and or with solar activity and their time evolution will be presented In the second phase of the project the frequency range will be increased to 1 2 - 1 7 2 8 and 5 6 GHz Central part of the array will consist of 26 antennas with 4-meter diameter laid out randomically in the square of 256 by 256 meter with minimum and maximum base lines of 8 and 256 meters respectively Details of this array with imaging capabilities in snap shot mode for solar observations and procedure of the phase and amplitude calibrations will be presented The development of instrument will be completed by the beginning of 2008
Dynamics of Two Interactive Bubbles in An Acoustic Field - Part II: Experiments
NASA Astrophysics Data System (ADS)
Ashgriz, Nasser; Barbat, Tiberiu; Liu, Ching-Shi
1996-11-01
The motion of two air bubbles levitated in water, in the presence of a high-frequency acoustic field is experimentally studied. The interaction force between them is named "secondary Bjerknes force" and may be significant in microgravity environments; in our experiments the buoyancy effect is compensated through the action of the "primary Bjerknes forces" - interaction between each bubble oscillation and external sound field. The stationary sound field is produced by a piezoceramic tranducer, in the range of 22-24 kHz. The experiments succesfully demonstrate the existence of three patterns of interaction between bubbles of various sizes: attraction, repulsion and oscillation. Bubbles attraction is quantitatively studied using a high speed video, for "large" bubbles (in the range 0.5-2 mm radius); bubbles repulsion and oscillations are only observed with a regular video, for "small" bubbles (around the resonance size at these frequencies, 0.12 mm). Velocities and accelerations of each bubble are computed from the time history of the motion. The theoretical equations of motion are completed with a drag force formula for single bubbles and solved numerically. Experimental results, for the case of two attracting bubbles, are in good agreement with the numerical model, especially for values of the mutual distance greater than 3 large bubble radii.
Modeling methodology for MLS range navigation system errors using flight test data
NASA Technical Reports Server (NTRS)
Karmali, M. S.; Phatak, A. V.
1982-01-01
Flight test data was used to develop a methodology for modeling MLS range navigation system errors. The data used corresponded to the constant velocity and glideslope approach segment of a helicopter landing trajectory. The MLS range measurement was assumed to consist of low frequency and random high frequency components. The random high frequency component was extracted from the MLS range measurements. This was done by appropriate filtering of the range residual generated from a linearization of the range profile for the final approach segment. This range navigation system error was then modeled as an autoregressive moving average (ARMA) process. Maximum likelihood techniques were used to identify the parameters of the ARMA process.
Os incae: variation in frequency in major human population groups
HANIHARA, TSUNEHIKO; ISHIDA, HAJIME
2001-01-01
The variation in frequency of the Inca bone was examined in major human populations around the world. The New World populations have generally high frequencies of the Inca bone, whereas lower frequencies occur in northeast Asians and Australians. Tibetan/Nepalese and Assam/Sikkim populations in northeast India have more Inca bones than do neighbouring populations. Among modern populations originally derived from eastern Asian population stock, the frequencies are highest in some of the marginal isolated groups. In Central and West Asia as well as in Europe, frequency of the Inca bone is relatively low. The incidence of the complete Inca bone is, moreover, very low in the western hemisphere of the Old World except for Subsaharan Africa. Subsaharan Africans show as a whole a second peak in the occurrence of the Inca bone. Geographical and ethnographical patterns of the frequency variation of the Inca bone found in this study indicate that the possible genetic background for the occurrence of this bone cannot be completely excluded. Relatively high frequencies of the Inca bone in Subsaharan Africans indicate that this trait is not a uniquely eastern Asian regional character. PMID:11273039
NASA Technical Reports Server (NTRS)
Aatrokoski, J.; Ade, P. A. R.; Aghanim, N.; Aller, H. D.; Aller, M. F.; Angelakis, E.; Amaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.;
2011-01-01
Spectral energy distributions (SEDs) and radio continuum spectra are presented for a northern sample of 104 extragalactic radio sources. based on the Planck Early Release Compact Source Catalogue (ERCSC) and simultaneous multi frequency data. The nine Planck frequencies, from 30 to 857 GHz, are complemented by a set of simultaneous observations ranging from radio to gamma-rays. This is the first extensive frequency coverage in the radio and millimetre domains for an essentially complete sample of extragalactic radio sources, and it shows how the individual shocks, each in their own phase of development, shape the radio spectra as they move in the relativistic jet. The SEDs presented in this paper were fitted with second and third degree polynomials to estimate the frequencies of the synchrotron and inverse Compton (IC) peaks, and the spectral indices of low and high frequency radio data, including the Planck ERCSC data, were calculated. SED modelling methods are discussed, with an emphasis on proper. physical modelling of the synchrotron bump using multiple components. Planck ERCSC data also suggest that the original accelerated electron energy spectrum could be much harder than commonly thought, with power-law index around 1.5 instead of the canonical 2.5. The implications of this are discussed for the acceleration mechanisms effective in blazar shock. Furthermore in many cases the Planck data indicate that gamma-ray emission must originate in the same shocks that produce the radio emission.
Toward an implantable functional electrical stimulation device to correct strabismus
Velez, Federico G.; Isobe, Jun; Zealear, David; Judy, Jack W.; Edgerton, V. Reggie; Patnode, Stephanie; Lee, Hyowon; Hahn, Brian T.
2010-01-01
PURPOSE To investigate the feasibility of electrically stimulating the lateral rectus muscle to recover its physiologic abduction ability in cases of complete sixth cranial (abducens) nerve palsy. METHODS In the feline lateral rectus muscle model, the effects of a charge-balanced, biphasic, current-controlled stimulus on the movement of the eye were investigated while stimulation frequency, amplitude, and pulse duration was varied. Eye deflection was measured with a force transducer. Denervated conditions were simulated by injection of botulinum toxin A. RESULTS Three chemically denervated and 4 control lateral rectus muscles were analyzed. In control lateral rectus muscles, the minimum fusion frequency was approximately 170 Hz, and the maximum evoked abduction was 27°. The minimum fusion frequency was unchanged after 4 weeks of chemical denervation. Stimulation of chemically denervated lateral rectus muscle resulted in 17° of abduction. For both innervated and chemically denervated lateral rectus muscle, frequencies greater than 175 Hz yielded very little increase in abduction. Modulating amplitude produced noticeable movement throughout the tested range (0.2 to 9 mA). CONCLUSIONS Results from the feline lateral rectus muscle showed that electrical stimulation is a feasible approach to evoke a contraction from a denervated lateral rectus muscle. The degree of denervation of the feline lateral rectus muscle was indeterminate. Varying the stimulation amplitude allowed greater eye movement. It is very likely that both frequency and amplitude must be modulated for finer control of static eye position. PMID:19375369
Celler, B G; Stella, A; Golin, R; Zanchetti, A
1996-08-01
In ten sino aortic denervated, vagotomized and aneasthetized cats, renal efferent nerves were stimulated for 30 s with trains of constant current pulses at frequencies in the range 5-30 Hz. The arterial pressure, heart rate, urine flow rate (electronic drop counter) and renal blood flow (electromagnetic technique) were recorded. Subsequent computer processing gave the true means of renal artery pressure (MRAP) and renal blood flow (MRBF) and hence the renal vascular resistance (MRVR), over each cardiac cycle. Recovery of MRVR after the end of stimulation exhibited two distinct time constants. The fast component had a time constant of 2.03 +/- 0.26 s and represented 60.2 +/- 1.71% of the recovery. The time constant of the slower component was 14.1 +/- 1.9 s and represented 36.0 +/- 1.6% of the recovery. The relationship between MRVR and stimulus frequency was sigmoidal with maximum sensitivity at stimulus frequencies of 12.6 +/- 0.76 Hz. Changes in urine flow rate, in contrast, followed a hyperbolic function with maximum response sensitivity occurring at very low stimulus frequencies. Changes in urine flow rate were 50% complete at stimulus frequencies of 5 Hz. Identification of two distinct components in the relaxation phase of renal vascular resistance leads to a reasonable hypothesis that 60% of total renal vascular resistance may lie proximal to the glomerulus, whereas 36% may be accounted for by the efferent arterioles.
Advanced Digital Signal Processing for Hybrid Lidar
2014-10-30
obtain range measurements . A MATLAB- based system developed at Clarkson University in FY14 has been used to perform real-time FDR ranging... measurement accuracy. There have been various methods that attempt to reduce the backscatter. One method is to increase the modulation frequency beyond...an unambiguous range measurement . In general, it is desired to determine which combination of Radio Frequency (RF) modulation frequencies, modulation
Kadota, Michio; Ago, Junya; Horiuchi, Hideya; Ikeura, Mamoru
2002-09-01
A shear horizontal (SH) wave has the characteristic of complete reflection at the free edges of a substrate with a large dielectric constant. A conventional surface acoustic wave (SAW) resonator filter requires reflectors consisting of numerous grating fingers on both sides of interdigital transducers (IDTs). On the contrary, it is considered that small-sized and low loss resonator filters without reflectors consisting of grating fingers can be realized by exploiting this characteristic of the SH wave or the Bleustein-Gulyaev-Shimizu (BGS) wave. There are two types of resonator filters: transversely coupled and longitudinally coupled. No transversely coupled filters (neither conventional nor edge-reflection) using the SH wave on a single-crystal substrate have been realized until now, because two transverse modes (symmetrical and asymmetrical modes) are not easily coupled. However, the authors have realized small low loss transversely coupled resonator filters in the range of 25 to 52 MHz using edge reflections of the BGS wave on piezoelectric ceramic (PZT: Pb(Zr,Ti)O3) substrates for the first time by developing methods by which the two transverse modes could be coupled. On the other hand, longitudinally coupled resonator filters using edge reflection of the SH or BGS wave always have large spurious responses because of the even modes in the out-of-band range, because the frequencies of even modes do not coincide with the nulls of the frequency spectra of the IDTs. Consequently, longitudinally coupled resonator filters using the edge reflection of the SH wave have not been realized. By developing a method of reducing the spurious responses without increasing of the insertion loss, the authors have realized small low loss longitudinally coupled resonator filters in the range of 40 to 190 MHz using edge reflection of BGS or SH waves on PZT or 36 degrees-rotated-Y X-propagation LiTaO3 substrates for the first time. Despite being intermediate frequency (IF) filters, their package (3 x 3 x 1.03 mm3) sizes are as small as those of radio frequency (RF) SAW filters.
Molgaard-Hansen, Lene; Skou, Anne-Sofie; Juul, Anders; Glosli, Heidi; Jahnukainen, Kirsi; Jarfelt, Marianne; Jónmundsson, Guðmundur K; Malmros, Johan; Nysom, Karsten; Hasle, Henrik
2013-12-01
More than 60% of children with acute myeloid leukemia (AML) become long-term survivors. Most are cured using chemotherapy without hematopoietic stem cell transplantation (HSCT). We report on pubertal development and compare self-reported parenthood among AML survivors and their siblings. We included 137 children treated for AML according to the Nordic Society of Pediatric Hematology and Oncology (NOPHO)-AML-84, -88, and -93 trials, who were alive by June 2007. Patients with relapse or treated with HSCT were excluded. AML survivors participated in a physical and biochemical examination (n = 102) and completed a questionnaire (n = 101). One of their siblings completed an identical questionnaire (n = 84). At a median follow-up of 11 years (range 5-25) after diagnosis of AML the survivors (median age 16 years, range 5-36) were either prepubertal or had entered puberty normally. Serum levels of FSH, LH, testosterone, estradiol, sex hormone binding globulin (SHBG), inhibin A and B, and testicular volumes were within normal ranges. Anti-Müllerian hormone (AMH) levels were decreased in 5 of 40 postpubertal females. Mean reported age at menarche was 13.1 (range 11-17) years. Among survivors 15 years of age or older 31% of females reported pregnancies and 9% of males reported pregnancies in their partners, rates comparable with the frequency reported by their siblings. Most AML survivors treated with chemotherapy had normal pubertal development and fertility, however, AMH levels were decreased in 13% of postpubertal females. Longer follow-up is necessary to evaluate possible risk of premature ovarian failure. © 2013 Wiley Periodicals, Inc.
Superconducting Solenoid for Superfast THz Spectroscopy
NASA Astrophysics Data System (ADS)
Bragin, A. V.; Khrushchev, S. V.; Kubarev, V. V.; Mezencev, N. A.; Tsukanov, V. M.; Sozinov, G. I.; Shkaruba, V. A.
This project is related to new spectroscopy method in little-developed THz range. The method is founded on using of a free electron laser (NovoFEL) with high spectral power radiation which can be smoothly tuned in desirable range of spectrum. The objects of research of this method are fast processes in physics, chemical and biological reactions. Uniform magnetic field of 6 T value in the research area can considerably increase possibilities of this method. The magnetic field will modulate radiation of free molecules induction on characteristic frequencies of the Zeeman splitting that gives more possibilities of identification of molecules having even weak magnetic momentum. Moreover, the use of magnetic field allows essentially increase sensitivity of this method due to almost complete separation of weak measuring signals from powerful radiation of the laser. A superconducting solenoid was developed for this method. Its design and peculiarities are described in this paper.
Design of CMOS imaging system based on FPGA
NASA Astrophysics Data System (ADS)
Hu, Bo; Chen, Xiaolai
2017-10-01
In order to meet the needs of engineering applications for high dynamic range CMOS camera under the rolling shutter mode, a complete imaging system is designed based on the CMOS imaging sensor NSC1105. The paper decides CMOS+ADC+FPGA+Camera Link as processing architecture and introduces the design and implementation of the hardware system. As for camera software system, which consists of CMOS timing drive module, image acquisition module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The ISE 14.6 emulator ISim is used in the simulation of signals. The imaging experimental results show that the system exhibits a 1280*1024 pixel resolution, has a frame frequency of 25 fps and a dynamic range more than 120dB. The imaging quality of the system satisfies the requirement of the index.
New designs of a complete set of Photonic Crystals logic gates
NASA Astrophysics Data System (ADS)
Hussein, Hussein M. E.; Ali, Tamer A.; Rafat, Nadia H.
2018-03-01
In this paper, we introduce new designs of all-optical OR, AND, XOR, NOT, NOR, NAND and XNOR logic gates based on the interference effect. The designs are built using 2D square lattice Photonic Crystal (PhC) structure of dielectric rods embedded in air background. The lattice constant, a, and the rod radius, r, are designed to achieve maximum operating range of frequencies using the gap map. We use the Plane Wave Expansion (PWE) method to obtain the band structure and the gap map of the proposed designs. The operating wavelengths achieve a wide band range that varies between 1266.9 nm and 1996 nm with center wavelength at 1550 nm. The Finite-Difference Time-Domain (FDTD) method is used to study the field behavior inside the PhC gates. The gates satisfy their truth tables with reasonable power contrast ratio between logic '1' and logic '0'.
NASA Astrophysics Data System (ADS)
Mehmood, Arshad; Zheng, Yuliang; Braun, Hubertus; Hovhannisyan, Martun; Letz, Martin; Jakoby, Rolf
2015-01-01
This paper presents the application of new high permittivity and low loss glass material for antennas. This glass material is transparent. A very simple rectangular dielectric resonator antenna is designed first with a simple microstrip feeding line. In order to widen the bandwidth, the feed of the design is modified by forming a T-shaped feeding. This new design enhanced the bandwidth range to cover the WLAN 5 GHz band completely. The dielectric resonator antenna cut into precise dimensions is placed on the modified microstrip feed line. The design is simple and easy to manufacture and also very compact in size of only 36 × 28 mm. A -10 dB impedance bandwidth of 18% has been achieved, which covers the frequency range from 5.15 GHz to 5.95 GHz. Simulations of the measured return loss and radiation patterns are presented and discussed.
Upgrade of JET AE Active Diagnostic for Low Frequency Eigenmodes Detection
NASA Astrophysics Data System (ADS)
Puglia, P.; Blanchard, P.; Testa, D.; Fasoli, A.; Aslanyan, V.; Porkolab, M.; Woskov, P.; Ruchko, L.; Galvao, R.; Pires de Sa, W.; Dos Reis, A.; Sharapov, S.; Dowson, S.,; Sheikh, H.; Blackman, T.; Jones, G.; Dorling, S.; Figueiredo, J.; Perez von Thun, C.; JET Collaboration
2017-10-01
The upgrade of the Toroidal Alfvén Eigenmode Active Antenna diagnostic at JET was commissioned last year. The new amplifiers have an operational frequency range limited to bands within 10-1000 kHz by a choice of filters. In the last campaigns the AE excitation system was operated on the Alfvénic range of frequencies (f > 80 kHz). For the next campaigns we are proposing operation on the frequency range of 25-50 kHz to excite eigenmodes on the Alfvén-acoustic range (GAMs, BAEs and Alfvén Cascades). The next JET campaigns will involve use of deuterium, tritium and hydrogen, giving a wide range of parameters for the modes to be investigated. Details of the system modifications for operation in this new frequency range and experimental scenarios will be discussed. This work has been carried out within the framework of the EUROfusion Consortium No 633053. Support was provided by the US DOE, FAPESP Project 2011/50773-0, by the Swiss NSF, and also the RCUK Energy Programme [Grant Number EP/P012450/1].
NASA Astrophysics Data System (ADS)
Zhang, Sai; Xu, Bai-qiang; Cao, Wenwu
2018-03-01
We have investigated low-frequency forbidden transmission (LFT) of acoustic waves with frequency lower than the first Bragg bandgap in a solid-fluid superlattice (SFSL). LFT is formed when the acoustic planar wave impinges on the interface of a SFSL within a certain angle range. However, for the SFSL comprised of metallic material and water, the angle range of LFT is extremely narrow, which restricts its practical applications. The variation characteristics of the angle range have been comprehensively studied here by the control variable method. The results suggest that the filling ratio, layer number, wave velocity, and mass density of the constituent materials have a significant impact on the angle range. Based on our results, an effective strategy for obtaining LFT with a broad angle range is provided, which will be useful for potential applications of LFT in various devices, such as low frequency filters and subwavelength one-way diodes.
NASA Astrophysics Data System (ADS)
Chao, Liu; Afsar, Mohammed N.; Ohkoshi, Shin-ichi
2015-05-01
In millimeter wave frequency range, hexagonal ferrites with high uniaxial anisotropic magnetic fields are used as absorbers. These ferrites include M-type barium ferrite (BaFe12O19) and strontium ferrite (SrFe12O19), which have natural ferromagnetic resonant frequency range from 40 GHz to 60 GHz. However, the higher frequency range lacks suitable materials that support the higher frequency ferromagnetic resonance. A series of gallium-substituted ɛ-iron oxides (ɛ-GaxFe2-xO3) are synthesized, which have ferromagnetic resonant frequencies appearing over the frequency range of 30 GHz to 150 GHz. The ɛ-GaxFe2-xO3 is synthesized by the sol-gel method. The particle sizes are observed to be smaller than 100 nm. In this paper, in-waveguide transmission and reflection method and the free space magneto-optical approach have been employed to study these newly developed ɛ-GaxFe2-xO3 particles in millimeter waves. These techniques enable to obtain precise transmission spectra to determine the dielectric and magnetic properties of both isotropic and anisotropic ferrites in the microwave and millimeter wave frequency range from single set of direct measurements. The complex dielectric permittivity and magnetic permeability spectra of ɛ-GaxFe2-xO3 are shown in this paper. Strong ferromagnetic resonances at different frequencies determined by the x parameter are found.
Temple, Duncan K; Cederlund, Anna A; Lawless, Bernard M; Aspden, Richard M; Espino, Daniel M
2016-10-06
The purpose of this study was to compare the frequency-dependent viscoelastic properties of human and bovine cartilage. Full-depth cartilage specimens were extracted from bovine and human femoral heads. Using dynamic mechanical analysis, the viscoelastic properties of eight bovine and six human specimens were measured over the frequency range 1 Hz to 88 Hz. Significant differences between bovine and human cartilage viscoelastic properties were assessed using a Mann-Whitney test (p < 0.05). Throughout the range of frequencies tested and for both species, the storage modulus was greater than the loss modulus and both were frequency-dependent. The storage and loss moduli of all human and bovine cartilage specimens presented a logarithmic relationship with respect to frequency. The mean human storage modulus ranged from 31.9 MPa to 43.3 MPa, while the mean bovine storage modulus ranged from 54.0 MPa to 80.5 MPa; bovine storage moduli were 1.7 to 1.9 times greater than the human modulus. Similarly, the loss modulus of bovine cartilage was 2.0 to 2.1 times greater than human. The mean human loss modulus ranged from 5.3 MPa to 8.5 MPa while bovine moduli ranged from 10.6 MPa to 18.1 MPa. Frequency-dependent viscoelastic trends of bovine articular cartilage were consistent with those of human articular cartilage; this includes a similar frequency dependency and high-frequency plateau. Bovine cartilage was, however, 'stiffer' than human by a factor of approximately 2. With these provisos, bovine articular cartilage may be a suitable dynamic model for human articular cartilage.
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates... level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a... used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in...
Moghadam, Shima Jowhari; Navarro, Laurent; Leclerc, Lara; Hodin, Sophie; Pourchez, Jérémie
2018-07-30
Treating chronic rhinosinusitis (CRS) by nebulization requires an airflow capable to deliver medication to deep target sites beyond the nasal valve. Fixed frequency acoustic airflow technology is currently available, mainly as post-surgical therapy, but still have not been able to realize the full potential of direct nose to paranasal sinuses delivery. Reported herein are the application of frequency sweep acoustic airflow and the optimization of its frequency range, sweep cycle duration and intensity. The resonant frequencies of the model's maxillary sinuses can be estimated using the Helmholtz resonator theory. Results indicated a resonant frequency of 479 Hz for the right maxillary sinus and one of 849 Hz for the left maxillary sinus. The highest intrasinus deposition within the experiments are from sweep cycle duration of 1 s, intensity of 80 dB, and frequency range of 100-850 Hz. The optimal range of frequency determined from experiments is in good agreement with the corresponding frequency range obtained from the Helmholtz resonator theory. Results reveal a significantly enhanced maxillary sinus drug deposition. This technique affords the potential of treating CRS. Copyright © 2018 Elsevier B.V. All rights reserved.
Relationships between Electroencephalographic Spectral Peaks Across Frequency Bands
van Albada, S. J.; Robinson, P. A.
2013-01-01
The degree to which electroencephalographic spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification. PMID:23483663
Wakeling, James M.
2015-01-01
This study investigated the influence of cycle frequency and workload on muscle coordination and the ensuing relationship with mechanical efficiency and power output of human limb movement. Eleven trained cyclists completed an array of cycle frequency (cadence)-power output conditions while excitation from 10 leg muscles and power output were recorded. Mechanical efficiency was maximized at increasing cadences for increasing power outputs and corresponded to muscle coordination and muscle fiber type recruitment that minimized both the total muscle excitation across all muscles and the ineffective pedal forces. Also, maximum efficiency was characterized by muscle coordination at the top and bottom of the pedal cycle and progressive excitation through the uniarticulate knee, hip, and ankle muscles. Inefficiencies were characterized by excessive excitation of biarticulate muscles and larger duty cycles. Power output and efficiency were limited by the duration of muscle excitation beyond a critical cadence (120–140 rpm), with larger duty cycles and disproportionate increases in muscle excitation suggesting deteriorating muscle coordination and limitations of the activation-deactivation capabilities. Most muscles displayed systematic phase shifts of the muscle excitation relative to the pedal cycle that were dependent on cadence and, to a lesser extent, power output. Phase shifts were different for each muscle, thereby altering their mechanical contribution to the pedaling action. This study shows that muscle coordination is a key determinant of mechanical efficiency and power output of limb movement across a wide range of mechanical demands and that the excitation and coordination of the muscles is limited at very high cycle frequencies. PMID:26445873
NASA Technical Reports Server (NTRS)
Desai, S. D.; Yuan, D. -N.
2006-01-01
A computationally efficient approach to reducing omission errors in ocean tide potential models is derived and evaluated using data from the Gravity Recovery and Climate Experiment (GRACE) mission. Ocean tide height models are usually explicitly available at a few frequencies, and a smooth unit response is assumed to infer the response across the tidal spectrum. The convolution formalism of Munk and Cartwright (1966) models this response function with a Fourier series. This allows the total ocean tide height, and therefore the total ocean tide potential, to be modeled as a weighted sum of past, present, and future values of the tide-generating potential. Previous applications of the convolution formalism have usually been limited to tide height models, but we extend it to ocean tide potential models. We use luni-solar ephemerides to derive the required tide-generating potential so that the complete spectrum of the ocean tide potential is efficiently represented. In contrast, the traditionally adopted harmonic model of the ocean tide potential requires the explicit sum of the contributions from individual tidal frequencies. It is therefore subject to omission errors from neglected frequencies and is computationally more intensive. Intersatellite range rate data from the GRACE mission are used to compare convolution and harmonic models of the ocean tide potential. The monthly range rate residual variance is smaller by 4-5%, and the daily residual variance is smaller by as much as 15% when using the convolution model than when using a harmonic model that is defined by twice the number of parameters.
A broadband high-transmission gradient phase discontinuity metasurface
NASA Astrophysics Data System (ADS)
Liu, Yahong; Liu, Congcong; Song, Kun; Li, Meize; Zhao, Xiaopeng
2018-03-01
Metasurfaces have attracted significant attention due to the control of the electromagnetic waves that they enable. In this paper, we demonstrate a high-transmission gradient phase discontinuity metasurface composed of metallic rods and cylindrical dielectric resonators operating at a broadband microwave frequency from 8 GHz to 9.8 GHz, with a fractional bandwidth of 20.2%. The proposed gradient phase discontinuity metasurface can achieve complete 2π transmission phase coverage with π/4 phase intervals by varying the geometric parameters of the dielectric resonators and metallic rods. It is shown that the proposed metasurface can refract a normally incident plane wave to an angle of 30°. The broadband metasurface is flexible, and the refracted angle can be adjusted easily by varying the lattice constant. Besides the broadband anomalous refraction, we also demonstrate the metasurface can produce an interesting vortex and wave-focusing in the wide frequency range from 8 GHz to 9.8 GHz. Finally, we demonstrate that the present metasurface can tailor interference wavefronts to plane wavefronts.
Jovian "sub-storm" and Its Influence On The Hectometric (hom) and Kilometric (kom) Emission
NASA Astrophysics Data System (ADS)
Boudjada, M. Y.; Galopeau, P. H. M.; Rucker, H. O.
We analyse the variation of the Jovian radio emission in the frequency range from 10 kHz up to 6 MHz by combining Galileo and Wind observations. We consider the emis- sion observed during the second GalileoSs orbit which corresponds to the period from 31st August to 23rd October 1996. For a given period of time, the central meridian longitudes associated to the observer (Wind or Galileo spacecraft) were completely different. This opportunity allows us to compare the variation of the hectometric radi- ation as observed by the two satellites, Wind on the dayside and Galileo on the night- side. We show that periodic intermittent enhancements of hectometric emission during long (few days) or short (few hours) intervals are quasi-simultaneously recorded by both spacecraft. Such Jovian Ssub-stormsT seem to affect also lower frequencies and & cedil;in particular the Jovian kilometric radiation. We discuss the spectral boundaries of the HOM and KOM emission during these particular phases, and their inter-correlations.
Investigation of the low-level modulated light action
NASA Astrophysics Data System (ADS)
Antonov, Sergei N.; Sotnikov, V. N.; Koreneva, L. G.
1994-07-01
Now there exists no clear complete knowledge about mechanisms and pathways by which low level laser bioactivation works. Modulated laser light action has been investigated two new ways: dynamical infrared thermography and computing image of living brain. These ways permit observation in real time laser action on peripheral blood flow, reflex reactions to functional probes, thermoregulation mechanisms as well as brain electrical activity changes of humans. We have designed a universal apparatus which produced all regimes of the output laser light. It has a built-in He-Ne laser with an acousto-optic modulator and an infrared GaAs laser. The device provided spatial combination of both the light beams and permitted us to irradiate an object both separately and simultaneously. This research shows that the most effective frequencies range from several to dozens of hertz. The duty factor and frequency scanning are also important. On the basis of these results in Russian clinics new treatment methods using modulated light are applied in practical neurology, gynecology, etc.
Optimization of a matched-filter receiver for frequency hopping code acquisition in jamming
NASA Astrophysics Data System (ADS)
Pawlowski, P. R.; Polydoros, A.
A matched-filter receiver for frequency hopping (FH) code acquisition is optimized when either partial-band tone jamming or partial-band Gaussian noise jamming is present. The receiver is matched to a segment of the FH code sequence, sums hard per-channel decisions to form a test, and uses multiple tests to verify acquisition. The length of the matched filter and the number of verification tests are fixed. Optimization is then choosing thresholds to maximize performance based upon the receiver's degree of knowledge about the jammer ('side-information'). Four levels of side-information are considered, ranging from none to complete. The latter level results in a constant-false-alarm-rate (CFAR) design. At each level, performance sensitivity to threshold choice is analyzed. Robust thresholds are chosen to maximize performance as the jammer varies its power distribution, resulting in simple design rules which aid threshold selection. Performance results, which show that optimum distributions for the jammer power over the total FH bandwidth exist, are presented.
Dielectric characterization of CuxS-NiySz/FNBR and CuS-NiySz/FNBR nanocomposites
NASA Astrophysics Data System (ADS)
Balayeva, Ofeliya O.; Azizov, Abdulsaid A.; Muradov, Mustafa B.; Eyvazova, Goncha M.
2017-06-01
CuxS-NiySz/FNBR and CuS-NiySz/FNBR nanocomposites (NCs) were prepared from β-NiS/FNBR by ion exchange method and dielectric characterized. Dielectric properties of NCs were investigated at the temperature of 26 °C-120 °C in 120-106 Hz frequency range. With measuring electric capacity and resistance of the samples at different frequency we have studied the dielectric permittivity, dielectric loss tangent, dielectric modulus, conductivity, relaxation times and Cole-Cole plots were obtained. At 120 °C measurement temperature, some of the destruction processes in polymers affect to interfacial interaction between the polymer and particles surface. After high temperature measurement all three samples were cooled to room temperature and their dielectric measurements were carried out at room temperature. It is observed that at high measurement temperature some of carriers transfer from one energy level to another and the dipole orientation did not return completely to the previous situation.
Lu, Jianing; Li, Xiang; Fu, Songnian; Luo, Ming; Xiang, Meng; Zhou, Huibin; Tang, Ming; Liu, Deming
2017-03-06
We present dual-polarization complex-weighted, decision-aided, maximum-likelihood algorithm with superscalar parallelization (SSP-DP-CW-DA-ML) for joint carrier phase and frequency-offset estimation (FOE) in coherent optical receivers. By pre-compensation of the phase offset between signals in dual polarizations, the performance can be substantially improved. Meanwhile, with the help of modified SSP-based parallel implementation, the acquisition time of FO and the required number of training symbols are reduced by transferring the complex weights of the filters between adjacent buffers, where differential coding/decoding is not required. Simulation results show that the laser linewidth tolerance of our proposed algorithm is comparable to traditional blind phase search (BPS), while a complete FOE range of ± symbol rate/2 can be achieved. Finally, performance of our proposed algorithm is experimentally verified under the scenario of back-to-back (B2B) transmission using 10 Gbaud DP-16/32-QAM formats.
Rotation Studies of Jovian Trojan Asteroids
NASA Astrophysics Data System (ADS)
French, Linda M.; Stephens, Robert D.; Wasserman, Lawrence H.; Lederer, Susan M.; Rohl, Derrick A.
2011-08-01
The Jovian Trojan asteroids appear to be fundamentally different from main belt asteroids. They formed further from the sun, they are of different composition, and their collisional history is different. Lightcurve studies provide information about the distribution of rotation frequencies of a group of asteroids. For main belt asteroids larger than about 40 km in diameter, the distribution of rotation frequencies is Maxwellian (Pravec et al. 2000). This suggests that collisions determine their rotation properties. Smaller main belt asteroids, however, show a predominance of both fast and slow rotators, with the observed spin distribution apparently controlled by the Yarkovsky-O'Keefe-Radzievskii-Paddack (YORP) effect (Pravec et al. 2008). The Trojans larger than 100 km in diameter have been almost completely sampled, but lightcurves for smaller Trojans have been less well studied due to their low albedos and greater solar distances. We propose to investigate the rotation periods of 4-6 small (D < 50 km) Trojan asteroids and 6-9 Trojans in the 50-100 km size range.
Solar Flare Dynamic Microwave Imaging with EOVSA
NASA Astrophysics Data System (ADS)
Gary, D. E.; Chen, B.; Nita, G. M.; Fleishman, G. D.; Yu, S.; White, S. M.; Hurford, G. J.; McTiernan, J. M.
2017-12-01
The Expanded Owens Valley Solar Array (EOVSA) is both an expansion of our existing solar array and serves as a prototype for a much larger future project, the Frequency Agile Solar Radiotelescope (FASR). EOVSA is now complete, and is producing daily imaging of the full solar disk, including active regions and solar radio bursts at hundreds of frequencies in the range 2.8-18 GHz. We present highlights of the 1-s-cadence dynamic imaging spectroscropy of radio bursts we have obtained to date, along with deeper analysis of multi-wavelength observations and modeling of a well-observed burst. These observations are revealing the full life-cycle of the trapped population of high-energy electrons, from their initial acceleration and subsequent energy-evolution to their eventual decay through escape and thermalization. All of our data are being made available for download in both quick-look image form and in the form of the community-standard CASA measurement sets for subsequent imaging and analysis.
Impact craters and Venus resurfacing history
NASA Technical Reports Server (NTRS)
Phillips, Roger J.; Raubertas, Richard F.; Arvidson, Raymond E.; Sarkar, Ila C.; Herrick, Robert R.; Izenberg, Noam; Grimm, Robert E.
1992-01-01
The history of resurfacing by tectonism and volcanism on Venus is reconstructed by means of an analysis of Venusian impact crater size-frequency distributions, locations, and preservation states. An atmospheric transit model for meteoroids demonstrates that for craters larger than about 30 km, the size-frequency distribution is close to the atmosphere-free case. An age of cessation of rapid resurfacing of about 500 Ma is obtained. It is inferred that a range of surface ages are recorded by the impact crater population; e.g., the Aphrodite zone is relatively young. An end-member model is developed to quantify resurfacing scenarios. It is argued that Venus has been resurfacing at an average rate of about 1 sq km/yr. Numerical simulations of resurfacing showed that there are two solution branches that satisfy the completely spatially random location restraint for Venusian craters: a is less than 0.0003 (4 deg diameter circle) and a is greater than 0.1 (74 deg diameter circle).
Status of the NASA SETI Sky Survey microwave observing project
NASA Technical Reports Server (NTRS)
Klein, M. J.; Gulkis, S.; Wilck, H. C.; Olsen, E. T.; Garyantes, M. F.; Burns, D. J.; Asmar, P. R.; Brady, R. B.; Deich, W. T. S.; Renzetti, N. A.
1992-01-01
The Sky Survey observing program is one of two complementary strategies that NASA plans to use in its microwave Search for Extraterrestrial Intelligence (SETI). The primary objective of the Sky Survey is to search the entire sky over the frequency range 1000-10,000 MHz for evidence of narrow band signals of extraterrestrial, intelligent origin. Spectrum analyzers with upwards of 10 million channels and data rates in excess of 10 gigabits per second are required to complete the survey in less than 7 years. To lay the foundation for the operational SETI Sky Survey, a prototype system has been built to test and refine real time signal detection algorithms, to test scan strategies and observatory control functions, and to test algorithms designed to reject radio frequency interference. This paper presents a high level description of the prototype hardware and reports on the preparations to deploy the system to the 34-m antenna at the research and development station of NASA's Deep Space Communication Complex, Goldstone, California.
Status of the NASA SETI Sky Survey microwave observing project.
Klein, M J; Gulkis, S; Wilck, H C; Olsen, E T; Garyantes, M F; Burns, D J; Asmar, P R; Brady, R B; Deich, W T; Renzetti, N A
1992-01-01
The Sky Survey observing program is one of two complementary strategies that NASA plans to use in its microwave Search for Extraterrestrial Intelligence (SETI). The primary objective of the Sky Survey is to search the entire sky over the frequency range 1000-10,000 MHz for evidence of narrow band signals of extraterrestrial, intelligent origin. Spectrum analyzers with upwards of 10 million channels and data rates in excess of 10 gigabits per second are required to complete the survey in less than 7 years. To lay the foundation for the operational SETI Sky Survey, a prototype system has been built to test and refine real time signal detection algorithms, to test scan strategies and observatory control functions, and to test algorithms designed to reject radio frequency interference. This paper presents a high level description of the prototype hardware and software and reports on the preparations to deploy the system to the 34-m antenna at the research and development station of NASA's Deep Space Communication Complex, Goldstone, California.
Tegeler, Charles H; Tegeler, Catherine L; Cook, Jared F; Lee, Sung W; Pajewski, Nicholas M
2015-06-01
Increased amplitudes in high-frequency brain electrical activity are reported with menopausal hot flashes. We report outcomes associated with the use of High-resolution, relational, resonance-based, electroencephalic mirroring--a noninvasive neurotechnology for autocalibration of neural oscillations--by women with perimenopausal and postmenopausal hot flashes. Twelve women with hot flashes (median age, 56 y; range, 46-69 y) underwent a median of 13 (range, 8-23) intervention sessions for a median of 9.5 days (range, 4-32). This intervention uses algorithmic analysis of brain electrical activity and near real-time translation of brain frequencies into variable tones for acoustic stimulation. Hot flash frequency and severity were recorded by daily diary. Primary outcomes included hot flash severity score, sleep, and depressive symptoms. High-frequency amplitudes (23-36 Hz) from bilateral temporal scalp recordings were measured at baseline and during serial sessions. Self-reported symptom inventories for sleep and depressive symptoms were collected. The median change in hot flash severity score was -0.97 (range, -3.00 to 1.00; P = 0.015). Sleep and depression scores decreased by -8.5 points (range, -20 to -1; P = 0.022) and -5.5 points (range, -32 to 8; P = 0.015), respectively. The median sum of amplitudes for the right and left temporal high-frequency brain electrical activity was 8.44 μV (range, 6.27-16.66) at baseline and decreased by a median of -2.96 μV (range, -11.05 to -0.65; P = 0.0005) by the final session. Hot flash frequency and severity, symptoms of insomnia and depression, and temporal high-frequency brain electrical activity decrease after High-resolution, relational, resonance-based, electroencephalic mirroring. Larger controlled trials with longer follow-up are warranted.
NASA Astrophysics Data System (ADS)
Studenikin, S. A.; Byszewski, M.; Maude, D. K.; Potemski, M.; Sachrajda, A.; Wasilewski, Z. R.; Hilke, M.; Pfeiffer, L. N.; West, K. W.
2006-08-01
Microwave induced resistance oscillations (MIROs) were studied experimentally over a very wide range of frequencies ranging from ∼20 GHz up to ∼4 THz, and from the quasi-classical regime to the quantum Hall effect regime. At low frequencies regular MIROs were observed, with a periodicity determined by the ratio of the microwave to cyclotron frequencies. For frequencies below 150 GHz the magnetic field dependence of MIROs waveform is well described by a simplified version of an existing theoretical model, where the damping is controlled by the width of the Landau levels. In the THz frequency range MIROs vanish and only pronounced resistance changes are observed at the cyclotron resonance. The evolution of MIROs with frequency is presented and discussed.
Rogue waves generation in a left-handed nonlinear transmission line with series varactor diodes
NASA Astrophysics Data System (ADS)
Onana Essama, B. G.; Atangana, J.; Biya Motto, F.; Mokhtari, B.; Cherkaoui Eddeqaqi, N.; Kofane, Timoleon C.
2014-07-01
We investigate the electromagnetic wave behavior and its characterization using collective variables technique. Second-order dispersion, first- and second-order nonlinearities, which strongly act in a left-handed nonlinear transmission line with series varactor diodes, are taken into account. Four frequency ranges have been found. The first one gives the so-called energetic soliton due to a perfect combination of second-order dispersion and first-order nonlinearity. The second frequency range presents a dispersive soliton leading to the collapse of the electromagnetic wave at the third frequency range. But the fourth one shows physical conditions which are able to provoke the appearance of wave trains generation with some particular waves, the rogue waves. Moreover, we demonstrate that the number of rogue waves increases with frequency. The soliton, thereafter, gains a relative stability when second-order nonlinearity comes into play with some specific values in the fourth frequency range. Furthermore, the stability conditions of the electromagnetic wave at high frequencies have been also discussed.
Principles of Space Plasma Wave Instrument Design
NASA Technical Reports Server (NTRS)
Gurnett, Donald A.
1998-01-01
Space plasma waves span the frequency range from somewhat below the ion cyclotron frequency to well above the electron cyclotron frequency and plasma frequency. Because of the large frequency range involved, the design of space plasma wave instrumentation presents many interesting challenges. This chapter discusses the principles of space plasma wave instrument design. The topics covered include: performance requirements, electric antennas, magnetic antennas, and signal processing. Where appropriate, comments are made on the likely direction of future developments.
Zhang, Ming
2014-07-01
Compared to auditory brainstem responses (ABRs), cochlear microphonics (CMs) may be more appropriate to serve as a supplement to the test of otoacoustic emissions (OAEs). Researchers have shown that low-frequency CMs from the apical cochlea are measurable at the tympanic membrane using high-pass masking noise. Our objective is to study the effect of such noise at different intensities on low-frequency CMs recorded at the ear canal, which is not completely known. Six components were involved in this CM measurement including an ear canal electrode (1), a relatively long and low-frequency toneburst (2), and high-pass masking noise at different intensities (3). The rest components include statistical analysis based on multiple human subjects (4), curve modeling based on amplitudes of CM waveforms (CMWs) and noise intensity (5), and a technique based on electrocochleography (ECochG or ECoG) (6). Results show that low-frequency CMWs appeared clearly. The CMW amplitude decreased with an increase in noise level. It decreased first slowly, then faster, and finally slowly again. In conclusion, when masked with high-pass noise, the low-frequency CMs are measurable at the human ear canal. Such noise reduces the low-frequency CM amplitude. The reduction is noise-intensity dependent but not completely linear. The reduction may be caused by the excited basal cochlea which the low-frequency has to travel and pass through. Although not completely clear, six mechanisms related to such reduction are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liao, Zhikun; Lu, Dawei; Hu, Jiemin; Zhang, Jun
2018-04-01
For the random hopping frequency signal, the modulated frequencies are randomly distributed over given bandwidth. The randomness of modulated frequency not only improves the electronic counter countermeasure capability for radar systems, but also determines its performance of range compression. In this paper, the range ambiguity function of RHF signal is firstly derived. Then, a design method of frequency hopping pattern based on stationary phase principle to improve the peak to side-lobe ratio is proposed. Finally, the simulated experiments show a good effectiveness of the presented design method.
Schultz-Lampel, D; Jiang, C; Lindström, S; Thüroff, J W
1998-01-01
Sacral foramen neuromodulation--initially applied for the treatment of urinary incontinence--has proved to be effective in patients with chronic urinary retention. Thus far, the underlying neurophysiological mechanisms have not been elucidated. In an experimental study on the neurophysiological basis of sacral neurostimulation, one objective was to investigate the mechanisms responsible for initiation of micturition in chronic urinary retention. In ten female cats anesthetized with alpha-chloralose the clinical situation of sacral foramen stimulation was experimentally reproduced by isolated S2 nerve stimulation after L6-S3 laminectomy. Stimulation responses were recorded from the bladder, peripheral nerves, and striated muscles of the foot and pelvic floor. The effect of sudden cessation of prolonged S2 stimulation, during which the bladder was completely inhibited, was evaluated in 70 stimulation sequences in 5 cats. Sacral nerve stimulation induced excitatory and inhibitory effects on the bladder, depending on the frequency and intensity of stimulation. With unilateral S2 stimulation, bladder excitation was best at frequencies of 2-5 Hz and at intensities ranging between 0.8 and 1.4 times the threshold for the M-response of the foot muscle. Inhibition was the dominating effect at frequencies of 7-10 Hz and at intensities exceeding 1.4 times the threshold. Prolonged S2 stimulation above the threshold produced complete bladder inhibition during stimulation but induced strong bladder contractions after sudden interruption of stimulation, with amplitudes being significantly higher than that of spontaneous contractions preceding the stimulation. These results confirm the hypothesis of a "rebound" phenomenon as the mechanism of action for induction of spontaneous voiding in patients with chronic urinary retention.
Parametric array technique for microbubble excitation.
Vos, Hendrik J; Goertz, David E; van der Steen, Antonius F W; de Jong, Nico
2011-05-01
This study investigates the use of an acoustic parametric array as a means for microbubble excitation. The excitation wave is generated during propagation in a nonlinear medium of two high-frequency carrier waves, whereby the frequency of the excitation wave is the difference frequency of the carrier waves. Carrier waves of around 10 and 25 MHz are used to generate low-frequency waves between 0.5 and 3.5 MHz at amplitudes in the range of 25 to 80 kPa in water. We demonstrate with high-speed camera observations that it is possible to induce microbubble oscillations with the low frequency signal arising from the nonlinear propagation process. As an application, we determined the resonance frequency of Definity contrast agent microbubbles with radius ranging from 1.5 to 5 μm by sweeping the difference frequency in the range from 0.5 to 3.5 MHz.
NASA Astrophysics Data System (ADS)
Stefan, V. Alexander; IAPS Team
The novel study of the epileptogenesis mechanisms is proposed. It is based on the pulsed-operated (amplitude modulation) multi-photon (frequency modulation) fiber-laser interaction with the brain epilepsy-topion (the epilepsy onset area), so as to prevent the excessive electrical discharge (epileptic seizure) in the brain. The repetition frequency, Ω, matches the low frequency (epileptic) phonon waves in the brain. The laser repetition frequency (5-100 pulses per second) enables the resonance-scanning of the wide range of the phonon (possible epileptic-to-be) activity in the brain. The tunable fiber laser frequencies, Δω (multi photon operation), are in the ultraviolet frequency range, thus enabling monitoring of the electrical charge imbalance (within the 10s of milliseconds), and the DNA-corruption in the epilepsy-topion, as the possible cause of the disease. Supported by Nikola Tesla Labs., Stefan University.
Conscious and unconscious processing of facial expressions: evidence from two split-brain patients.
Prete, Giulia; D'Ascenzo, Stefania; Laeng, Bruno; Fabri, Mara; Foschi, Nicoletta; Tommasi, Luca
2015-03-01
We investigated how the brain's hemispheres process explicit and implicit facial expressions in two 'split-brain' patients (one with a complete and one with a partial anterior resection). Photographs of faces expressing positive, negative or neutral emotions were shown either centrally or bilaterally. The task consisted in judging the friendliness of each person in the photographs. Half of the photograph stimuli were 'hybrid faces', that is an amalgamation of filtered images which contained emotional information only in the low range of spatial frequency, blended to a neutral expression of the same individual in the rest of the spatial frequencies. The other half of the images contained unfiltered faces. With the hybrid faces the patients and a matched control group were more influenced in their social judgements by the emotional expression of the face shown in the left visual field (LVF). When the expressions were shown explicitly, that is without filtering, the control group and the partially callosotomized patient based their judgement on the face shown in the LVF, whereas the complete split-brain patient based his ratings mainly on the face presented in the right visual field. We conclude that the processing of implicit emotions does not require the integrity of callosal fibres and can take place within subcortical routes lateralized in the right hemisphere. © 2013 The British Psychological Society.
Development of PZT Actuated Valveless Micropump.
Munas, Fathima Rehana; Melroy, Gehan; Abeynayake, Chamitha Bhagya; Chathuranga, Hiniduma Liyanage; Amarasinghe, Ranjith; Kumarage, Pubudu; Dau, Van Thanh; Dao, Dzung Viet
2018-04-24
A piezoelectrically actuated valveless micropump has been designed and developed. The principle components of this system are piezoelectrically actuated (PZT) metal diaphragms and a complete fluid flow system. The design of this pump mainly focuses on a cross junction, which is generated by a nozzle jet attached to a pump chamber and the intersection of two inlet channels and an outlet channel respectively. During each PZT diaphragm vibration cycle, the junction connecting the inlet and outlet channels with the nozzle jet permits consistencies in fluidic momentum and resistances in order to facilitate complete fluidic path throughout the system, in the absence of any physical valves. The entire micropump structure is fabricated as a plate-by-plate element of polymethyl methacrylate (PMMA) sheets and sandwiched to get required fluidic network as well as the overall device. In order to identify the flow characteristics, and to validate the test results with numerical simulation data, FEM analysis using ANSYS was carried out and an eigenfrequency analysis was performed to the PZT diaphragm using COMSOL Multiphysics. In addition, the control system of the pump was designed and developed to change the applied frequency to the piezoelectric diaphragms. The experimental data revealed that the maximum flow rate is 31.15 mL/min at a frequency of 100 Hz. Our proposed design is not only for a specific application but also useful in a wide range of biomedical applications.
Propagation model for the Land Mobile Satellite channel in urban environments
NASA Technical Reports Server (NTRS)
Sforza, M.; Dibernardo, G.; Cioni, R.
1993-01-01
This paper presents the major characteristics of a simulation package capable of performing a complete narrow and wideband analysis of the mobile satellite communication channel in urban environments for any given orbital configuration. The wavelength-to-average urban geometrical dimension ratio has required the use of the Geometrical Theory of Diffraction (GTD). For the RF frequency range, the model has been designed to be (1 up to 60 GHz) extended to include effects of non-perfect conductivity and surface roughness. Taking advantage of the inherent capabilities of such a high frequency method, we are able to provide a complete description of the electromagnetic field at the mobile terminal. Using the information made available at the ray-tracer and GTD solver outputs, the Land Mobile Satellite (LMS) urban model can also give a detailed description of the communication channel in terms of power delay profiles, Doppler spectra, channel scattering functions, and so forth. Statistical data, e.g. cumulative distribution functions, level crossing rates or distributions of fades are also provided. The user can access the simulation tool through a Design-CAD user-friendly interface by means of which she can effectively design her own urban layout and run consequently all the envisaged routines. The software is optimized in its execution time so that numerous runs can be achieved in a considerably short time.
Ramo, Danielle E.; Liu, Howard; Prochaska, Judith J.
2012-01-01
With growing interest in online assessment of substance abuse behaviors, there is a need to formally evaluate the validity of the data gathered. The current investigation evaluated the reliability and validity of anonymous, online reports of young adults’ marijuana use and related cognitions. Young adults age 18 to 25 who had smoked at least one cigarette in the past 30 days were recruited over 14 months to complete an anonymous online survey. Of 3106 eligible cases, 1617 (52%) completed the entire survey. Of those, 54% (n = 884) reported past-month marijuana use (65% male, 70% Caucasian, mean age was 20.4 years [SD = 2.0]). Prevalence of marijuana use was reported reliably across three similar items, and inter-item correlations ranged from fair to excellent for measures of marijuana dependence symptoms and thoughts about marijuana use. Marijuana use frequency demonstrated good construct validity through expected correlations with marijuana use constructs, and non-significant correlations with thoughts about tobacco use. Marijuana frequency distinguished among stages of change for marijuana use and goals for use, but not among gender, ethnicity, or employment groups. Marijuana use and thoughts about use differed by stage of change in the hypothesized directions. Self-reported marijuana use and associated cognitions reported anonymously online from young adults are generally reliable and valid. Online assessments of substance use broaden the reach of addictions research. PMID:22082344
Disability perception in Menière's disease: when, how much and why?
Soto-Varela, Andres; Huertas-Pardo, Belen; Gayoso-Diz, Pilar; Santos-Perez, Sofia; Sanchez-Sellero, Ines
2016-04-01
The purpose of the study was to evaluate self-perceived handicap in patients with definite Menière's disease (MD). A cross-sectional study was conducted. To examine the self-perception of disability, participants completed a DHI (Dizziness Handicap Inventory). Parameters compared with DHI scores: sex, age, unilateral/bilateral affectation, time elapsed since the onset of symptoms, pure-tone average (PTA), stages of MD, audiometric change (last 6 months), PTA in low frequencies (PTAl) and audiometric change in PTAl, subjective perception of fluctuating hearing threshold, tinnitus between attacks, number of vertiginous episodes (last 6 months), time elapsed since last attack, subjective perception of instability intercrises and Tumarkin attacks. 90 patients were included; they completed a total of 104 questionnaires. DHI scores ranged from 2 to 100 (average: 47.08, SD 24.45). In 29 cases (27.9 %) the disability perception was mild, in 43 (41.3 %) moderate, and in 32 (30.8 %) severe. Correlation between disability perception and some vestibular symptoms was found: number of typical attacks (last 6 months), time elapsed since last attack, instability intercrises and Tumarkin attacks. No relationship was found with the rest of variables. Disability perception in patients with MD depends primarily on vestibular symptoms (particularly, instability and frequency of attacks). So, we suggest to design a new staging system of MD taking into account both auditory criteria and also vestibular symptoms.
Glottal behavior in the high soprano range and the transition to the whistle register.
Garnier, Maëva; Henrich, Nathalie; Crevier-Buchman, Lise; Vincent, Coralie; Smith, John; Wolfe, Joe
2012-01-01
The high soprano range was investigated by acoustic and electroglottographic measurements of 12 sopranos and high-speed endoscopy of one of these. A single laryngeal transition was observed on glissandi above the primo passaggio. It supports the existence of two distinct laryngeal mechanisms in the high soprano range: M2 and M3, underlying head and whistle registers. The laryngeal transition occurred gradually over several tones within the interval D#5-D6. It occurred over a wider range and was completed at a higher pitch for trained than untrained sopranos. The upper limit of the laryngeal transition during glissandi was accompanied by pitch jumps or instabilities, but, for most singers, it did not coincide with the upper limit of R1:f(0) tuning (i.e., tuning the first resonance to the fundamental frequency). However, pitch jumps could also be associated with changes in resonance tuning. Four singers demonstrated an overlap range over which they could sing with a full head or fluty resonant quality. Glottal behaviors underlying these two qualities were similar to the M2 and M3 mechanisms respectively. Pitch jumps and discontinuous glottal and spectral changes characteristic of a M2-M3 laryngeal transition were observed on decrescendi produced within this overlap range. © 2012 Acoustical Society of America.
Mechanism of blood pressure and R-R variability: insights from ganglion blockade in humans
NASA Technical Reports Server (NTRS)
Zhang, Rong; Iwasaki, Kenichi; Zuckerman, Julie H.; Behbehani, Khosrow; Crandall, Craig G.; Levine, Benjamin D.; Blomqvist, C. G. (Principal Investigator)
2002-01-01
Spontaneous blood pressure (BP) and R-R variability are used frequently as 'windows' into cardiovascular control mechanisms. However, the origin of these rhythmic fluctuations is not completely understood. In this study, with ganglion blockade, we evaluated the role of autonomic neural activity versus other 'non-neural' factors in the origin of BP and R-R variability in humans. Beat-to-beat BP, R-R interval and respiratory excursions were recorded in ten healthy subjects (aged 30 +/- 6 years) before and after ganglion blockade with trimethaphan. The spectral power of these variables was calculated in the very low (0.0078-0.05 Hz), low (0.05-0.15 Hz) and high (0.15-0.35 Hz) frequency ranges. The relationship between systolic BP and R-R variability was examined by cross-spectral analysis. After blockade, R-R variability was virtually abolished at all frequencies; however, respiration and high frequency BP variability remained unchanged. Very low and low frequency BP variability was reduced substantially by 84 and 69 %, respectively, but still persisted. Transfer function gain between systolic BP and R-R interval variability decreased by 92 and 88 % at low and high frequencies, respectively, while the phase changed from negative to positive values at the high frequencies. These data suggest that under supine resting conditions with spontaneous breathing: (1) R-R variability at all measured frequencies is predominantly controlled by autonomic neural activity; (2) BP variability at high frequencies (> 0.15 Hz) is mediated largely, if not exclusively, by mechanical effects of respiration on intrathoracic pressure and/or cardiac filling; (3) BP variability at very low and low frequencies (< 0.15 Hz) is probably mediated by both sympathetic nerve activity and intrinsic vasomotor rhythmicity; and (4) the dynamic relationship between BP and R-R variability as quantified by transfer function analysis is determined predominantly by autonomic neural activity rather than other, non-neural factors.
The Frequency of School Resource Officer Tasks and Incidents of School Violence
ERIC Educational Resources Information Center
Lane, James F.
2009-01-01
The purpose of this study was to determine if differences in the frequency of school resource officer behaviors exist and if any differences in behaviors were related to differences in the frequency of incidents of school violence. This study collected information about tasks that SROs complete and compared that information to the frequency of…
Similarity of Symbol Frequency Distributions with Heavy Tails
NASA Astrophysics Data System (ADS)
Gerlach, Martin; Font-Clos, Francesc; Altmann, Eduardo G.
2016-04-01
Quantifying the similarity between symbolic sequences is a traditional problem in information theory which requires comparing the frequencies of symbols in different sequences. In numerous modern applications, ranging from DNA over music to texts, the distribution of symbol frequencies is characterized by heavy-tailed distributions (e.g., Zipf's law). The large number of low-frequency symbols in these distributions poses major difficulties to the estimation of the similarity between sequences; e.g., they hinder an accurate finite-size estimation of entropies. Here, we show analytically how the systematic (bias) and statistical (fluctuations) errors in these estimations depend on the sample size N and on the exponent γ of the heavy-tailed distribution. Our results are valid for the Shannon entropy (α =1 ), its corresponding similarity measures (e.g., the Jensen-Shanon divergence), and also for measures based on the generalized entropy of order α . For small α 's, including α =1 , the errors decay slower than the 1 /N decay observed in short-tailed distributions. For α larger than a critical value α*=1 +1 /γ ≤2 , the 1 /N decay is recovered. We show the practical significance of our results by quantifying the evolution of the English language over the last two centuries using a complete α spectrum of measures. We find that frequent words change more slowly than less frequent words and that α =2 provides the most robust measure to quantify language change.
Kinematic Clues to OB Field Star Origins: Radial Velocities, Runaways, and Binaries
NASA Astrophysics Data System (ADS)
Januszewski, Helen; Castro, Norberto; Oey, Sally; Becker, Juliette; Kratter, Kaitlin M.; Mateo, Mario; Simón-Díaz, Sergio; Bjorkman, Jon E.; Bjorkman, Karen; Sigut, Aaron; Smullen, Rachel; M2FS Team
2018-01-01
Field OB stars are a crucial probe of star formation in extreme conditions. Properties of massive stars formed in relative isolation can distinguish between competing star formation theories, while the statistics of runaway stars allow an indirect test of the densest conditions in clusters. To address these questions, we have obtained multi-epoch, spectroscopic observations for a spatially complete sample of 48 OB field stars in the SMC Wing with the IMACS and M2FS multi-object spectrographs at the Magellan Telescopes. The observations span 3-6 epochs per star, with sampling frequency ranging from one day to about one year. From these spectra, we have calculated the radial velocities (RVs) and, in particular, the systemic velocities for binaries. Thus, we present the intrinsic RV distribution largely uncontaminated by binary motions. We estimate the runaway frequency, corresponding to the high velocity stars in our sample, and we also constrain the binary frequency. The binary frequency and fitted orbital parameters also place important constraints on star formation theories, as these properties drive the process of runaway ejection in clusters, and we discuss these properties as derived from our sample. This unique kinematic analysis of a high mass field star population thus provides a new look at the processes governing formation and interaction of stars in environments at extreme densities, from isolation to dense clusters.
Licensing of future mobile satellite systems
NASA Technical Reports Server (NTRS)
Lepkowski, Ronald J.
1990-01-01
The regulatory process for licensing mobile satellite systems is complex and can require many years to complete. This process involves frequency allocations, national licensing, and frequency coordination. The regulatory process that resulted in the establishment of the radiodetermination satellite service (RDSS) between 1983 and 1987 is described. In contrast, each of these steps in the licensing of the mobile satellite service (MSS) is taking a significantly longer period of time to complete.
Frequency-dependent complex modulus of the uterus: preliminary results
NASA Astrophysics Data System (ADS)
Kiss, Miklos Z.; Hobson, Maritza A.; Varghese, Tomy; Harter, Josephine; Kliewer, Mark A.; Hartenbach, Ellen M.; Zagzebski, James A.
2006-08-01
The frequency-dependent complex moduli of human uterine tissue have been characterized. Quantification of the modulus is required for developing uterine ultrasound elastography as a viable imaging modality for diagnosing and monitoring causes for abnormal uterine bleeding and enlargement, as well assessing the integrity of uterine and cervical tissue. The complex modulus was measured in samples from hysterectomies of 24 patients ranging in age from 31 to 79 years. Measurements were done under small compressions of either 1 or 2%, at low pre-compression values (either 1 or 2%), and over a frequency range of 0.1-100 Hz. Modulus values of cervical tissue monotonically increased from approximately 30-90 kPa over the frequency range. Normal uterine tissue possessed modulus values over the same range, while leiomyomas, or uterine fibroids, exhibited values ranging from approximately 60-220 kPa.
NASA Astrophysics Data System (ADS)
Kim, Sun Ho; Hwang, Yong Seok; Jeong, Seung Ho; Wang, Son Jong; Kwak, Jong Gu
2017-10-01
An efficient current drive scheme in central or off-axis region is required for the steady state operation of tokamak fusion reactors. The current drive by using the fast wave in frequency range higher than two times lower hybrid resonance (w>2wlh) could be such a scheme in high density, high temperature reactor-grade tokamak plasmas. First, it has relatively higher parallel electric field to the magnetic field favorable to the current generation, compared to fast waves in other frequency range. Second, it can deeply penetrate into high density plasmas compared to the slow wave in the same frequency range. Third, parasitic coupling to the slow wave can contribute also to the current drive avoiding parametric instability, thermal mode conversion and ion heating occured in the frequency range w<2wlh. In this study, the propagation boundary, accessibility, and the energy flow of the fast wave are given via cold dispersion relation and group velocity. The power absorption and current drive efficiency are discussed qualitatively through the hot dispersion relation and the polarization. Finally, those characteristics are confirmed with ray tracing code GENRAY for the KSTAR plasmas.
NASA Astrophysics Data System (ADS)
Setiono, Andi; Ula, Rini Khamimatul; Hanto, Dwi; Widiyatmoko, Bambang; Purnamaningsih, Retno Wigajatri
2016-02-01
In general, Fiber Bragg Grating (FBG) sensor works based on observation of spectral response characteristic to detect the desired parameter. In this research, we studied intensity response characteristic of FBG to detect the dynamic strain. Experiment result show that the reflected intensity had linier relationships with dynamic strain. Based on these characteristics, we developed the FBG sensor to detect low frequency vibration. This sensor is designed by attaching the FBG on the bronze cantilever with dimensions of 85×3×0.5 mm. Measurement results showed that the sensor was able to detect vibrations in the frequency range of 7-10 Hz at temperature range of 25-45 ˚C. The measured frequency range is still within the frequency range of digging activity, therefore this vibration sensor can be applied for oil pipelines vandalisation detection system.
A 155-dB Dynamic Range Current Measurement Front End for Electrochemical Biosensing.
Dai, Shanshan; Perera, Rukshan T; Yang, Zi; Rosenstein, Jacob K
2016-10-01
An integrated current measurement system with ultra wide dynamic range is presented and fabricated in a 180-nm CMOS technology. Its dual-mode design provides concurrent voltage and frequency outputs, without requiring an external clock source. An integrator-differentiator core provides a voltage output with a noise floor of 11.6 fA/ [Formula: see text] and a -3 dB cutoff frequency of 1.4 MHz. It is merged with an asynchronous current-to-frequency converter, which generates an output frequency linearly proportional to the input current. Together, the voltage and frequency outputs yield a current measurement range of 155 dB, spanning from 204 fA (100 Hz) or 1.25 pA (10 kHz) to 11.6 μA. The proposed architecture's low noise, wide bandwidth, and wide dynamic range make it ideal for measurements of highly nonlinear electrochemical and electrophysiological systems.
NASA Technical Reports Server (NTRS)
Zhang, R.; Zuckerman, J. H.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)
2000-01-01
To determine the dependence of cerebral blood flow (CBF) on arterial pressure over prolonged time periods, we measured beat-to-beat changes in mean CBF velocity in the middle cerebral artery (transcranial Doppler) and mean arterial pressure (Finapres) continuously for 2 h in six healthy subjects (5 men and 1 woman, 18-40 yr old) during supine rest. Fluctuations in velocity and pressure were quantified by the range [(peak - trough)/mean] and coefficients of variation (SD/mean) in the time domain and by spectral analysis in the frequency domain. Mean velocity and pressure over the 2-h recordings were 60 +/- 7 cm/s and 83 +/- 8 mmHg, associated with ranges of 77 +/- 8 and 89 +/- 10% and coefficients of variation of 9.3 +/- 2.2 and 7.9 +/- 2.3%, respectively. Spectral power of the velocity and pressure was predominantly distributed in the frequency range of 0.00014-0.1 Hz and increased inversely with frequency, indicating characteristics of an inverse power law (1/f(alpha)). However, linear regression on a log-log scale revealed that the slope of spectral power of pressure and velocity was steeper in the high-frequency (0.02-0.5 Hz) than in the low-frequency range (0.002-0.02 Hz), suggesting different regulatory mechanisms in these two frequency ranges. Furthermore, the spectral slope of pressure was significantly steeper than that of velocity in the low-frequency range, consistent with the low transfer function gain and low coherence estimated at these frequencies. We conclude that 1) long-term fluctuations in CBF velocity are prominent and similar to those observed in arterial pressure, 2) spectral power of CBF velocity reveals characteristics of 1/f(alpha), and 3) cerebral attenuation of oscillations in CBF velocity in response to changes in pressure may be more effective at low than that at high frequencies, emphasizing the frequency dependence of cerebral autoregulation.
Techniques for Computation of Frequency Limited H∞ Norm
NASA Astrophysics Data System (ADS)
Haider, Shafiq; Ghafoor, Abdul; Imran, Muhammad; Fahad Mumtaz, Malik
2018-01-01
Traditional H ∞ norm depicts peak system gain over infinite frequency range, but many applications like filter design, model order reduction and controller design etc. require computation of peak system gain over specific frequency interval rather than infinite range. In present work, new computationally efficient techniques for computation of H ∞ norm over frequency limited interval are proposed. Proposed techniques link norm computation with maximum singular value of the system in limited frequency interval. Numerical examples are incorporated to validate the proposed concept.
A frequency averaging framework for the solution of complex dynamic systems
Lecomte, Christophe
2014-01-01
A frequency averaging framework is proposed for the solution of complex linear dynamic systems. It is remarkable that, while the mid-frequency region is usually very challenging, a smooth transition from low- through mid- and high-frequency ranges is possible and all ranges can now be considered in a single framework. An interpretation of the frequency averaging in the time domain is presented and it is explained that the average may be evaluated very efficiently in terms of system solutions. PMID:24910518
Oscillator or Amplifier With Wide Frequency Range
NASA Technical Reports Server (NTRS)
Kleinberg, L.; Sutton, J.
1987-01-01
Inductive and capacitive effects synthesized with feedback circuits. Oscillator/amplifier resistively tunable over wide frequency range. Feedback circuits containing operational amplifiers, resistors, and capacitors synthesize electrical effects of inductance and capacitance in parallel between input terminals. Synthetic inductance and capacitance, and, therefore, resonant frequency of input admittance, adjusted by changing potentiometer setting.
Taeduk Radio Astronomy Observatory and Key Science Programs
NASA Astrophysics Data System (ADS)
Lee, Youngung; Kang, H. W.; Jung, J. H.; Lee, C. H.; Kim, Y. S.; Kim H. G.
2018-06-01
Taeduk Radio Astronomy Observatory (TRAO) is now equipped with a new main control computer with VxWorks operating system, a new receiver system, and a new backend system. The receiver system(SEQUOIA-TRAO) is equipped with high-performing 16-pixel MMIC pre-amplifiers in a 4x4 array, operating within 85~115 GHz frequency range. The system temperature ranges from 150 K(85 GHz) to 400 K(115 GHz). The 2nd IF modules with the narrow band and the 8 channels with 4 FFT spectrometers allow to observe 2 frequencies simultaneously within the 85~100 or 100~115 GHz bands for all 16 pixels. Radome replacement was completed successfully in February 2017. In addition, a new servo system was installed in 2017 autumn season, providing faster and more stable tracking mode of the telescope. Thus we can save telescope time at least 10%. We are providing OTF(On-The-Fly) as a main observing mode, and position switching mode is available as well. The backend system(FFT spectrometer) provides the 4096x2 channels with fine velocity resolution of about 0.05 km/sec(15 kHz) per channel, and their full spectra bandwidth is 60 MHz. Beam efficiency of the TRAO was measured to be about 46% - 54% (with less than 2% error) between 85 and 115 GHz frequency range. The pointing errors of the 14m telescope were found be 4.4 arcsec in AZ direction and 6 arcsec in EL direction. Generally, we allocate 18 hours of telescope time a day from January to the middle of May, and from October to December. Three Key Science Programs had been selected in 2015 fall and they are supposed to have higher priority for telescope time, up to 50%. General proposals from enthusiastic mm-wave astronomers from any country are encouraged.
Montagna, Fabio; Buiatti, Marco; Benatti, Simone; Rossi, Davide; Farella, Elisabetta; Benini, Luca
2017-10-01
EEG is a standard non-invasive technique used in neural disease diagnostics and neurosciences. Frequency-tagging is an increasingly popular experimental paradigm that efficiently tests brain function by measuring EEG responses to periodic stimulation. Recently, frequency-tagging paradigms have proven successful with low stimulation frequencies (0.5-6Hz), but the EEG signal is intrinsically noisy in this frequency range, requiring heavy signal processing and significant human intervention for response estimation. This limits the possibility to process the EEG on resource-constrained systems and to design smart EEG based devices for automated diagnostic. We propose an algorithm for artifact removal and automated detection of frequency tagging responses in a wide range of stimulation frequencies, which we test on a visual stimulation protocol. The algorithm is rooted on machine learning based pattern recognition techniques and it is tailored for a new generation parallel ultra low power processing platform (PULP), reaching performance of more that 90% accuracy in the frequency detection even for very low stimulation frequencies (<1Hz) with a power budget of 56mW. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Kraft, R. E.; Yu, J.; Kwan, H. W.
1999-01-01
The primary purpose of this study is to develop improved models for the acoustic impedance of treatment panels at high frequencies, for application to subscale treatment designs. Effects that cause significant deviation of the impedance from simple geometric scaling are examined in detail, an improved high-frequency impedance model is developed, and the improved model is correlated with high-frequency impedance measurements. Only single-degree-of-freedom honeycomb sandwich resonator panels with either perforated sheet or "linear" wiremesh faceplates are considered. The objective is to understand those effects that cause the simple single-degree-of- freedom resonator panels to deviate at the higher-scaled frequency from the impedance that would be obtained at the corresponding full-scale frequency. This will allow the subscale panel to be designed to achieve a specified impedance spectrum over at least a limited range of frequencies. An advanced impedance prediction model has been developed that accounts for some of the known effects at high frequency that have previously been ignored as a small source of error for full-scale frequency ranges.
Device and method for generating a beam of acoustic energy from a borehole, and applications thereof
Vu, Cung Khac; Sinha, Dipen N; Pantea, Cristian; Nihei, Kurt T; Schmitt, Denis P; Skelt, Christopher
2013-10-01
In some aspects of the invention, a method of generating a beam of acoustic energy in a borehole is disclosed. The method includes generating a first broad-band acoustic pulse at a first broad-band frequency range having a first central frequency and a first bandwidth spread; generating a second broad-band acoustic pulse at a second broad-band frequency range different than the first frequency range having a second central frequency and a second bandwidth spread, wherein the first acoustic pulse and second acoustic pulse are generated by at least one transducer arranged on a tool located within the borehole; and transmitting the first and the second broad-band acoustic pulses into an acoustically non-linear medium, wherein the composition of the non-linear medium produces a collimated pulse by a non-linear mixing of the first and second acoustic pulses, wherein the collimated pulse has a frequency equal to the difference in frequencies between the first central frequency and the second central frequency and a bandwidth spread equal to the sum of the first bandwidth spread and the second bandwidth spread.
Radar network communication through sensing of frequency hopping
Dowla, Farid; Nekoogar, Faranak
2013-05-28
In one embodiment, a radar communication system includes a plurality of radars having a communication range and being capable of operating at a sensing frequency and a reporting frequency, wherein the reporting frequency is different than the sensing frequency, each radar is adapted for operating at the sensing frequency until an event is detected, each radar in the plurality of radars has an identification/location frequency for reporting information different from the sensing frequency, a first radar of the radars which senses the event sends a reporting frequency corresponding to its identification/location frequency when the event is detected, and all other radars in the plurality of radars switch their reporting frequencies to match the reporting frequency of the first radar upon detecting the reporting frequency switch of a radar within the communication range. In another embodiment, a method is presented for communicating information in a radar system.
Multibeam single frequency synthetic aperture radar processor for imaging separate range swaths
NASA Technical Reports Server (NTRS)
Jain, A. (Inventor)
1982-01-01
A single-frequency multibeam synthetic aperture radar for large swath imaging is disclosed. Each beam illuminates a separate ""footprint'' (i.e., range and azimuth interval). The distinct azimuth intervals for the separate beams produce a distinct Doppler frequency spectrum for each beam. After range correlation of raw data, an optical processor develops image data for the different beams by spatially separating the beams to place each beam of different Doppler frequency spectrum in a different location in the frequency plane as well as the imaging plane of the optical processor. Selection of a beam for imaging may be made in the frequency plane by adjusting the position of an aperture, or in the image plane by adjusting the position of a slit. The raw data may also be processed in digital form in an analogous manner.
Webcam delivery of the Camperdown Program for adolescents who stutter: a phase II trial.
Carey, Brenda; O'Brian, Sue; Lowe, Robyn; Onslow, Mark
2014-10-01
This Phase II clinical trial examined stuttering adolescents' responsiveness to the Webcam-delivered Camperdown Program. Sixteen adolescents were treated by Webcam with no clinic attendance. Primary outcome was percentage of syllables stuttered (%SS). Secondary outcomes were number of sessions, weeks and hours to maintenance, self-reported stuttering severity, speech satisfaction, speech naturalness, self-reported anxiety, self-reported situation avoidance, self-reported impact of stuttering, and satisfaction with Webcam treatment delivery. Data were collected before treatment and up to 12 months after entry into maintenance. Fourteen participants completed the treatment. Group mean stuttering frequency was 6.1 %SS (range, 0.7-14.7) pretreatment and 2.8 %SS (range, 0-12.2) 12 months after entry into maintenance, with half the participants stuttering at 1.2 %SS or lower at this time. Treatment was completed in a mean of 25 sessions (15.5 hr). Self-reported stuttering severity ratings, self-reported stuttering impact, and speech satisfaction scores supported %SS outcomes. Minimal anxiety was evident either pre- or post-treatment. Individual responsiveness to the treatment varied, with half the participants showing little reduction in avoidance of speech situations. The Webcam service delivery model was appealing to participants, although it was efficacious and efficient for only half. Suggestions for future stuttering treatment development for adolescents are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei
2013-11-15
An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperaturemore » of atmospheric pressure plasma could also be obtained using dual-frequency excitation.« less
NASA Astrophysics Data System (ADS)
Grimm, Alice; Laureanti, Nicole; Rodakoviski, Rodrigo
2016-04-01
This study aims to clarify the impact of interdecadal climate oscillations (periods of 8 years and longer) on the frequency of extreme precipitation events over South America in the monsoon season (austral spring and summer), and determine the influence of these oscillations on the daily precipitation frequency distribution. Interdecadal variability modes of precipitation during the monsoon season are provided by a continental-scale rotated empirical orthogonal function analysis for the 60 years period 1950-2009. The main disclosed modes are robust, since they are reproduced for different periods. They can produce differences around 50% in monthly precipitation between opposite phases. Oceanic and atmospheric anomalous fields associated with these modes indicate that they have physical basis. The first modes in spring and summer display highest correlation with the Interdecadal Pacific Oscillation (IPO) SST mode, while the second modes have strongest correlation with the Atlantic Multidecadal Oscillation (AMO) SST mode. However, there are also other influences on these modes. As the most dramatic consequences of climate variability stem from its influence on the frequency of extreme precipitation events, it is important to also assess this influence, since variations in monthly or seasonal precipitation do not necessarily imply significant alterations in their extreme events. This study seeks to answer the questions: i) Do opposite phases of the main interdecadal modes of seasonal precipitation produce significant anomalies in the frequency of extreme events? ii) Does the interdecadal variability of the frequency of extreme events show similar spatial and temporal structure as the interdecadal variability of the seasonal precipitation? iii) Does the interdecadal variability change the daily precipitation probability distribution between opposite phases? iv) In this case, which ranges of daily precipitation are most affected? The significant anomalies of the extreme events frequency in opposite phases of the interdecadal oscillations display spatial patterns very similar to those of the corresponding modes. In addition, the modes of extreme events frequency bear similarity to the modes of seasonal precipitation, although a complete assessment of this similarity is not possible with the daily data available. The Kolmogorov-Smirnov test is applied to the daily precipitation series for positive and negative phases of the interdecadal modes, in regions with high factor loadings. It shows, with significance level better than 0.01, that daily precipitation from opposite phases pertains to different frequency distributions. Further analyses disclose clearly that there is much greater relative impact of the interdecadal oscillations on the extreme ranges of daily rainfall than in the ranges of moderate and light rainfall. This impact is more linear is spring than in summer. Acknowledgments: This work was supported by: Inter-American Institute for Global Change Research (IAI) CRN3035 which is supported by the US National Science Foundation (Grant GEO-1128040), European Community's Seventh Framework Programme under Grant Agreement n° 212492 (CLARIS LPB), and CNPq-Brazil (National Council for Scientific and Technologic Development).
NASA Astrophysics Data System (ADS)
Stefan, V. Alexander; IAPS-team Team
2017-10-01
The novel study of the laser excitation-suppression of the brain waves is proposed. It is based on the pulsed-operated multi-photon fiber-laser interaction with the brain parvalbumin (PV) neurons. The repetition frequency matches the low frequency brain waves (5-100 Hz); enabling the resonance-scanning of the wide range of the PV neurons (the generators of the brain wave activity). The tunable fiber laser frequencies are in the ultraviolet frequency range, thus enabling the monitoring of the PV neuron-DNA, within the 10s of milliseconds. In medicine, the method can be used as an ``instantaneous-on-off anesthetic.'' Supported by Nikola Tesla Labs, Stefan University.
NASA Astrophysics Data System (ADS)
Zhang, Jingdong; Zhu, Tao; Zheng, Hua; Kuang, Yang; Liu, Min; Huang, Wei
2017-04-01
The round trip time of the light pulse limits the maximum detectable frequency response range of vibration in phase-sensitive optical time domain reflectometry (φ-OTDR). We propose a method to break the frequency response range restriction of φ-OTDR system by modulating the light pulse interval randomly which enables a random sampling for every vibration point in a long sensing fiber. This sub-Nyquist randomized sampling method is suits for detecting sparse-wideband- frequency vibration signals. Up to MHz resonance vibration signal with over dozens of frequency components and 1.153MHz single frequency vibration signal are clearly identified for a sensing range of 9.6km with 10kHz maximum sampling rate.
van der Walt, Chris L E; Heyns, Chris F; Groeneveld, Adam E; Edlin, Rachel S; van Vuuren, Stephan P J
2011-07-01
To evaluate the correlation between the International Prostate Symptom Score (IPSS) and a new Visual Prostate Symptom Score (VPSS) using pictures rather than words to assess lower urinary tract symptoms (LUTS). Four IPSS questions related to frequency, nocturia, weak stream, and quality of life (QoL) were represented by pictograms in the VPSS. Men with LUTS were given the IPSS and VPSS to complete. Peak (Qmax.) and average (Qave.) urinary flow rates were measured. Statistical analysis was performed using Student's t, Fisher's exact, and Spearman's correlation tests. The educational level of the 96 men (mean age 64, range 33-85 years) evaluated August 2009 to August 2010 was school grade 8-12 (62%), grade 1-7 (28%), university education (6%), and no schooling (4%). The IPSS was completed without assistance by 51 of 96 men (53%) and the VPSS by 79 of 96 men (82%) (P<.001). Comparing education grade<7 vs grade>10 groups, the IPSS required assistance in 27 of 31 men (87%) vs 9 of 38 men (24%) (P<.001), and the VPSS required assistance in 10 of 31 men (32%) vs 3 of 38 men (8%) (P=.014). There were statistically significant correlations between total VPSS, Qmax. and Qave., total VPSS and IPSS, and individual VPSS parameters (frequency, nocturia, weak stream and QoL) vs their IPSS counterparts. The VPSS correlates significantly with the IPSS, Qmax. and Qave., and can be completed without assistance by a greater proportion of men with limited education, indicating that it may be more useful than the IPSS in patients who are illiterate or have limited education. Copyright © 2011 Elsevier Inc. All rights reserved.
Frequency and characteristics of Internet use by Spanish teenagers. A cross-sectional study.
Reolid-Martínez, Ricardo E; Flores-Copete, María; López-García, Mónica; Alcantud-Lozano, Pilar; Ayuso-Raya, María Candelaria; Escobar-Rabadán, Francisco
2016-02-01
Internet has completely changed communication among people in today's world, especially among young users. The objective of this study is to establish the frequency of Internet use by teenagers, and most used apps. This was a crosssectional study. In November 2013, students attending two mandatory secondary schools in Albacete were invited to complete a self-administered questionnaire with close-ended and open questions. Questionnaires were completed in the classroom, either "online" or "with pen and paper". Answers were entered in a computer database using the SPSS 17.0 software. Statistical analysis included a comparison of proportions (χ² test) and mean/median values (Student's t test/non-parametric tests). Nine hundred and sixty-seven students participated; their mean age was 13.8 years old (range: 11-20); 53.5% were girls. Most students (70.9%) lived in the city. Most belonged to a middle (51.3%) and high (34.8%) socioeconomic status. Also most students went online on a daily basis (73.4%); only 0.9% indicated that they never did. The most frequently used apps included WhatsApp (77.1%), social networks (70.1%) and music apps (66.6%). Among girls, the most common Internet use was social networks (p= 0.004), WhatsApp (p < 0.0001), Instagram (p < 0.0001) and listening to music (p= 0.004). Boys most commonly used the Internet to browse the web (p < 0.0001), Skype (p=0.001), play (p < 0.0001) andwatchmovies or TV shows (p= 0.035). Internet takes up a large part of the time in adolescents' lives, especially as a means of communications, being WhatsApp and social networks the most commonly used apps. Sociedad Argentina de Pediatría.
The Complete, Temperature Resolved Experimental Spectrum of Methanol Between 560 and 654 GHZ
NASA Astrophysics Data System (ADS)
Fortman, Sarah M.; Neese, Christopher F.; De Lucia, Frank C.
2013-06-01
The complete spectrum of methanol (CH_3OH) in the 560.4-654.0 GHz spectral region has been characterized over a range of astrophysically significant temperatures, 248-397 K. Analysis of experimental spectra recorded with absolute intensity calibration over a slow temperature ramp provides a means for the simulation of the spectrum as a function of temperature without a complete quantum mechanical (QM) model. These results include contributions from v_t = 3 and other higher states that are difficult to model via QM techniques. They also contain contributions from the ^{13}C isotopologue in natural abundance. These results are used to both provide catalogs in the usual line frequency, linestrength, and lower state energy format and in a frequency point-by-point format that is particularly well suited for the characterization of blended lines. In contrast to our earlier work on the semi-rigid species ethyl cyanide and vinyl cyanide, significant intensity difference between these experimental values and those calculated by QM methods were found for some of the lines. Analysis of these differences points to the difficulty of the calculation of dipole matrix elements in the context of the internal rotation of the methanol molecule. We will compare our experimental intensities with the most recent QM model, as well as an earlier QM model that includes the variation of the dipole moment function with the torsional angle. S. M. Fortman, I. R. Medvedev, C. F. Neese, and F. C. De Lucia, Astrophys. J. 737, 20/1-6 (2011). L.-H. Xu, et al. J. Mol. Spectrosc. 251, 305-313 (2008). M. A. Mekhtiev, P. D. Godfrey, and J. T. Hougen, J. Mol. Spectrosc. 194, 171-178 (1999).
Range Sidelobe Suppression Using Complementary Sets in Distributed Multistatic Radar Networks
Wang, Xuezhi; Song, Yongping; Huang, Xiaotao; Moran, Bill
2017-01-01
We propose an alternative waveform scheme built on mutually-orthogonal complementary sets for a distributed multistatic radar. Our analysis and simulation show a reduced frequency band requirement for signal separation between antennas with centralized signal processing using the same carrier frequency. While the scheme can tolerate fluctuations of carrier frequencies and phases, range sidelobes arise when carrier frequencies between antennas are significantly different. PMID:29295566
NASA Astrophysics Data System (ADS)
Zhou, Peng; Zhang, Xi; Sun, Weifeng; Dai, Yongshou; Wan, Yong
2018-01-01
An algorithm based on time-frequency analysis is proposed to select an imaging time window for the inverse synthetic aperture radar imaging of ships. An appropriate range bin is selected to perform the time-frequency analysis after radial motion compensation. The selected range bin is that with the maximum mean amplitude among the range bins whose echoes are confirmed to be contributed by a dominant scatter. The criterion for judging whether the echoes of a range bin are contributed by a dominant scatter is key to the proposed algorithm and is therefore described in detail. When the first range bin that satisfies the judgment criterion is found, a sequence composed of the frequencies that have the largest amplitudes in every moment's time-frequency spectrum corresponding to this range bin is employed to calculate the length and the center moment of the optimal imaging time window. Experiments performed with simulation data and real data show the effectiveness of the proposed algorithm, and comparisons between the proposed algorithm and the image contrast-based algorithm (ICBA) are provided. Similar image contrast and lower entropy are acquired using the proposed algorithm as compared with those values when using the ICBA.
Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use
Arthur, Steve M.; Schwartz, Charles C.
1999-01-01
We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area <1%/additional location) and precise (CV < 50%). Although the radiotracking data appeared unbiased, except for the relationship between area and sample size, these data failed to indicate some areas that likely were important to bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.
Binesh, Fariba; Akhondei, Mohsen; Pourmirafzali, Hamideh; Rajabzadeh, Yavar
2013-05-01
To determine eosinophil and mast cell populations in gastric and duodenal mucosal biopsies of adults with nonulcer dyspepsia (NUD) as compared to non-dyspeptic adults. A case control study. Shahid Sadoughi University of Medical Sciences, Yazd, Iran, from January 2010 to June 2011. A total of 52 (25 non-ulcer dyspeptic patients as case and 27 non-dyspeptic patients as control) patients underwent endoscopy. All patients had a minimum of 2 forceps biopsies obtained from stomach and duodenum. Routine histological evaluation was performed and additionally evaluated to determine eosinophil and mast cell counts. The statistical analysis was performed on SPSS version 17.0, using Mann-Whitney test with significance at p < 0.05. The mean age in the case and control groups was 31.72 ± 12.17 and 35.74 ± 12.42 years respectively. The median eosinophil density in gastric mucosa in case group was 5.0 (ranging from 1 to 20) and 4.0 in control group (ranging from 0 to 16; p = 0.140). The median eosinophil density in duodenal mucosa in case group was 16.0 (ranging from 2 to 24) and 13 in control group (ranging from 2 to 45; p = 0.147). The median mast cell density in gastric mucosa in case group was 4.0 (ranging from 0 to 33) and 4.0 in control group (ranging from 0 to 26; p = 0.827). The median mast cell density in duodenal mucosa in case group was 4.0 (ranging from 0 to 31) and 3.0 in control group (ranging from 1 to 23; p = 0.704). The frequency of Helicobacter pylori infection in both the groups was similar. Although there were not statistically significant differences in eosinophil and mast cell densities between case and control groups, there was a trend toward mild eosinophilia in gastric and duodenal mucosa. The specific role of eosinophils and mast cells in NUD is yet to be completely defined.
Hermannsen, Line; Beedholm, Kristian; Tougaard, Jakob; Madsen, Peter T
2014-10-01
Growing ship traffic worldwide has led to increased vessel noise with possible negative impacts on marine life. Most research has focused on low frequency components of ship noise, but for high-frequency specialists, such as the harbor porpoise (Phocoena phocoena), medium-to-high frequency noise components are likely more of a concern. To test for biologically relevant levels of medium-to-high frequency vessel noise, different types of Automatic Identification System located vessels were recorded using a broadband recording system in four heavily ship-trafficked marine habitats in Denmark. Vessel noise from a range of different ship types substantially elevated ambient noise levels across the entire recording band from 0.025 to 160 kHz at ranges between 60 and 1000 m. These ship noise levels are estimated to cause hearing range reduction of >20 dB (at 1 and 10 kHz) from ships passing at distances of 1190 m and >30 dB reduction (at 125 kHz) from ships at distances of 490 m or less. It is concluded that a diverse range of vessels produce substantial noise at high frequencies, where toothed whale hearing is most sensitive, and that vessel noise should be considered over a broad frequency range, when assessing noise effects on porpoises and other small toothed whales.
2010-09-30
proposal include: 1) complete the development of second-generation sonar boards, 2) complete the integration of new transducers with the second... sonar board and transducer. APPROACH Over the last 40 years, there has been significant research effort directed towards the use of high...narrowband frequency, and some AUVs carry single-frequency sidescan sonars (and this technology has been adapted for gliders), the lack of suitable
New findings and instrumentation from the NASA Lewis microgravity facilities
NASA Technical Reports Server (NTRS)
Ross, Howard D.; Greenberg, Paul S.
1990-01-01
The study of fundamental combustion and fluid physics in a microgravity environment is a relatively new scientific endeavor. The microgravity environment enables a new range of experiments to be performed since: buoyancy-induced flows are nearly eliminated; normally obscured forces and flows may be isolated; gravitational settling or sedimentation is nearly eliminated; and larger time or length scales in experiments become permissible. Unexpected phenomena have been observed, with surprising frequency, in microgravity experiments, raising questions about the degree of accuracy and completeness of the classical understanding. An overview is provided of some new phenomena found through ground-based, microgravity research, the instrumentation used in this research, and plans for new instrumentation.
Simulation of the dynamic environment for missile component testing: Demonstration
NASA Technical Reports Server (NTRS)
Chang, Kurng Y.
1989-01-01
The problems in defining a realistic test requirement for missile and space vehicle components can be classified into two categories: (1) definition of the test environment representing the expected service condition, and (2) simulation of the desired environment in the test laboratory. Recently, a new three-dimensional (3-D) test facility was completed at the U.S. Army Harry Diamond Laboratory (HDL) to simulate triaxial vibration input to a test specimen. The vibration test system is designed to support multi-axial vibration tests over the frequency range of 5 to 2000 Hertz. The availability of this 3-D test system motivates the development of new methodologies addressing environmental definition and simulation.
Network of Porosity Formed in Ultrafine-Grained Copper Produced by Equal Channel Angular Pressing
NASA Astrophysics Data System (ADS)
Ribbe, Jens; Baither, Dietmar; Schmitz, Guido; Divinski, Sergiy V.
2009-04-01
Radiotracer experiments on diffusion of Ni63 and Rb86 in severely deformed commercially pure copper (8 passes of equal channel angular pressing) reveal unambiguously the existence of ultrafast transport paths. A fraction of these paths remains in the material even after complete recrystallization. Scanning electron microscopy and focused ion beam techniques are applied. Deep grooves are found which are related to original high-energy interfaces. In-depth sectioning near corresponding triple junctions reveals clearly multiple microvoids or microcracks caused by the severe deformation. Long-range tracer penetration over tens of micrometers proves that these submicrometer-large defects are connected by highly diffusive paths and that they appear with significant frequency.
Tunable THz polariton laser based on 1342 nm wavelength for enhanced terahertz wave extraction.
Lee, Andrew J; Spence, David J; Pask, Helen M
2017-07-15
We detail the operation of a THz laser source based on non-linear stimulated polariton scattering (SPS) in Mg:LiNbO3. This system utilizes a fundamental wavelength of 1342 nm to completely avoid the negative effect of free-carrier generation within high-resistivity silicon (Si) prisms used to extract THz radiation from the Mg:LiNbO3 crystal. THz power of up to 23.6 μW (62.3 μW when chopped at 50% duty cycle) was detected at 1.33 THz, and frequency tunability across the range 1.05-2.2 THz was achieved.
Ultramicrowave communications system, phase 2
NASA Technical Reports Server (NTRS)
1980-01-01
Communications system design was completed and reviewed. Minor changes were made in order to make it more cost effective and to increase design flexibility. System design activities identified the techniques and procedures to generate and monitor high data rate test signals. Differential bi-phase demodulation is the proposed method for this system. The mockup and packaging designs were performed, and component layout and interconnection constraints were determined, as well as design drawings for dummy parts of the system. The possibility of adding a low cost option to the transceiver system was studied. The communications program has the advantage that new technology signal processing devices can be readily interfaced with the existing radio frequency subsystem to produce a short range radar.
The 15-meter diameter mechanically scanned deployable antenna
NASA Technical Reports Server (NTRS)
Coyner, J. V.; Herbert, J. J.; Bachtell, E. E.
1982-01-01
A preliminary design with structural model data and thermal-performance estimates of a 15-meter mechanically scanned deployable antenna (MSDA) that could be launched onboard a Shuttle Orbiter to provide radiometric brightness temperature maps of the Earth and oceans in selected bands over a frequency range from 1.4 to 11 GHz is provided. The study objectives were met through the design of a unique, integrated, offset feed mast and reflector design that uses the deployable box-truss structure as a building block. The performance of this system is summarized. The all graphite-epoxy, 4.57-meter prototype cube that was completed in 1981 and is proposed for this reflector and feed mast design is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, M. S.; Guo, Wenfeng
2016-06-15
The frequency spectrum and mode structure of axisymmetric electrostatic oscillations [the zonal flow (ZF), sound waves (SW), geodesic acoustic modes (GAM), and electrostatic mean flows (EMF)] in tokamaks with general cross-sections and toroidal flows are studied analytically using the electrostatic approximation for magnetohydrodynamic modes. These modes constitute the “electrostatic continua.” Starting from the energy principle for a tokamak plasma with toroidal rotation, we showed that these modes are completely stable. The ZF, the SW, and the EMF could all be viewed as special cases of the general GAM. The Euler equations for the general GAM are obtained and are solvedmore » analytically for both the low and high range of Mach numbers. The solution consists of the usual countable infinite set of eigen-modes with discrete eigen-frequencies, and two modes with lower frequencies. The countable infinite set is identified with the regular GAM. The lower frequency mode, which is also divergence free as the plasma rotation tends to zero, is identified as the ZF. The other lower (zero) frequency mode is a pure geodesic E×B flow and not divergence free is identified as the EMF. The frequency of the EMF is shown to be exactly 0 independent of plasma cross-section or its flow Mach number. We also show that in general, sound waves with no geodesic components are (almost) completely lost in tokamaks with a general cross-sectional shape. The exception is the special case of strict up-down symmetry. In this case, half of the GAMs would have no geodesic displacements. They are identified as the SW. Present day tokamaks, although not strictly up-down symmetric, usually are only slightly up-down asymmetric. They are expected to share the property with the up-down symmetric tokamak in that half of the GAMs would be more sound wave-like, i.e., have much weaker coupling to the geodesic components than the other half of non-sound-wave-like modes with stronger coupling to the geodesic displacements. Based on the general notion that the geodesic component of the GAM is more effective in tearing up the eddies in the electrostatic turbulence, it is important to preferentially excite the GAMs that are non-sound-wave like to maximize the efficiency on turbulence suppression through external means. Finally, approximate formulae for the frequencies of the EMF, ZF, SW, and the GAM for a large aspect ratio circular tokamak rotating at low Mach numbers are also provided.« less
Dual-Band Deramp Radar Design for Ocean Current Measurements
NASA Technical Reports Server (NTRS)
Haynes, Mark S.
2005-01-01
A mission has been proposed to remotely measure ocean surface currents and surface wind velocities. It will provide the highest resolution and repeat time of these measurements to date for ocean current models with scientific and societal applications. A ground-based experimental radar unit is needed for proof of concept. The proposed experiment set up is to mount the radar on an oil rig to imitate satellite data acquisition. This summer, I completed the radar design. The design employs chirp/deramp topology with simultaneous transmit/receive channels. These two properties allow large system bandwidth, extended sample time, close range imaging, and low sampling rate. The radar operates in the Ku and Ka microwave bands, at 13.5 and 35.5 GHz, respectively, with a system bandwidth of 300 MHz. I completed the radar frequency analysis and research on potential components and antenna configurations. Subsequent work is needed to procure components, as well as to build, test, and deploy the radar.
Schottky Heterodyne Receivers With Full Waveguide Bandwidth
NASA Technical Reports Server (NTRS)
Hesler, Jeffrey; Crowe, Thomas
2011-01-01
Compact THz receivers with broad bandwidth and low noise have been developed for the frequency range from 100 GHz to 1 THz. These receivers meet the requirements for high-resolution spectroscopic studies of planetary atmospheres (including the Earth s) from spacecraft, as well as airborne and balloon platforms. The ongoing research is significant not only for the development of Schottky mixers, but also for the creation of a receiver system, including the LO chain. The new receivers meet the goals of high sensitivity, compact size, low total power requirement, and operation across complete waveguide bands. The exceptional performance makes these receivers ideal for the broader range of scientific and commercial applications. These include the extension of sophisticated test and measurement equipment to 1 THz and the development of low-cost imaging systems for security applications and industrial process monitoring. As a particular example, a WR-1.9SHM (400-600 GHz) has been developed (see Figure 1), with state-of-the-art noise temperature ranging from 1,000-1,800 K (DSB) over the full waveguide band. Also, a Vector Network Analyzer extender has been developed (see Figure 2) for the WR1.5 waveguide band (500 750 GHz) with 100-dB dynamic range.
All-digital phase-lock loops for noise-free signals
NASA Technical Reports Server (NTRS)
Anderson, T. O.
1973-01-01
Bit-synchronizers utilize all-digital phase-lock loops that are referenced to a high frequency digital clock. Phase-lock loop of first design acquires frequency within nominal range and tracks phase; second design is modified for random binary data by addition of simple transition detector; and third design acquires frequency over wide dynamic range.
Microwave spectral line listing
NASA Technical Reports Server (NTRS)
White, W. F., Jr.
1975-01-01
The frequency, intensity, and identification of 9615 spectral lines belonging to 75 molecules are tabulated in order of increasing frequency. Measurements for all 75 molecules were made in the frequency range from 26500 to 40000 MHz by a computer controlled spectrometer. Measurements were also made in the 18000 to 26500 MHz range for some of the molecules.
Experimental study on the sound absorption characteristics of continuously graded phononic crystals
NASA Astrophysics Data System (ADS)
Zhang, X. H.; Qu, Z. G.; He, X. C.; Lu, D. L.
2016-10-01
Novel three-dimensional (3D) continuously graded phononic crystals (CGPCs) have been designed, and fabricated by 3D printing. Each of the CGPCs is an entity instead of a combination of several other samples, and the porosity distribution of the CGPC along the incident direction is nearly linear. The sound absorption characteristics of CGPCs were experimentally investigated and compared with those of uniform phononic crystals (UPCs) and discretely stepped phononic crystals (DSPCs). Experimental results show that CGPCs demonstrate excellent sound absorption performance because of their continuously graded structures. CGPCs have higher sound absorption coefficients in the large frequency range and more sound absorption coefficient peaks in a specific frequency range than UPCs and DSPCs. In particular, the sound absorption coefficients of the CGPC with a porosity of 0.6 and thickness of 30 mm are higher than 0.56 when the frequency is 1350-6300 Hz and are all higher than 0.2 in the studied frequency range (1000-6300 Hz). CGPCs are expected to have potential application in noise control, especially in the broad frequency and low-frequency ranges.
Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel
NASA Technical Reports Server (NTRS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.
2008-01-01
Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
Re-Active Passive devices for control of noise transmission through a panel
NASA Astrophysics Data System (ADS)
Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan
2008-01-01
Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.
Selection Signature Analysis Implicates the PC1/PCSK1 Region for Chicken Abdominal Fat Content
Wang, Zhipeng; Zhang, Yuandan; Wang, Shouzhi; Wang, Ning; Ma, Li; Leng, Li; Wang, Shengwen; Wang, Qigui; Wang, Yuxiang; Tang, Zhiquan; Li, Ning; Da, Yang; Li, Hui
2012-01-01
We conducted a selection signature analysis using the chicken 60k SNP chip in two chicken lines that had been divergently selected for abdominal fat content (AFC) for 11 generations. The selection signature analysis used multiple signals of selection, including long-range allele frequency differences between the lean and fat lines, long-range heterozygosity changes, linkage disequilibrium, haplotype frequencies, and extended haplotype homozygosity. Multiple signals of selection identified ten signatures on chromosomes 1, 2, 4, 5, 11, 15, 20, 26 and Z. The 0.73 Mb PC1/PCSK1 region of the Z chromosome at 55.43-56.16 Mb was the most heavily selected region. This region had 26 SNP markers and seven genes, Mar-03, SLC12A2, FBN2, ERAP1, CAST, PC1/PCSK1 and ELL2, where PC1/PCSK1 are the chicken/human names for the same gene. The lean and fat lines had two main haplotypes with completely opposite SNP alleles for the 26 SNP markers and were virtually line-specific, and had a recombinant haplotype with nearly equal frequency (0.193 and 0.196) in both lines. Other haplotypes in this region had negligible frequencies. Nine other regions with selection signatures were PAH-IGF1, TRPC4, GJD4-CCNY, NDST4, NOVA1, GALNT9, the ESRP2-GALR1 region with five genes, the SYCP2-CADH4 with six genes, and the TULP1-KIF21B with 14 genes. Genome-wide association analysis showed that nearly all regions with evidence of selection signature had SNP effects with genome-wide significance (P<10–6) on abdominal fat weight and percentage. The results of this study provide specific gene targets for the control of chicken AFC and a potential model of AFC in human obesity. PMID:22792402
Selection signature analysis implicates the PC1/PCSK1 region for chicken abdominal fat content.
Zhang, Hui; Hu, Xiaoxiang; Wang, Zhipeng; Zhang, Yuandan; Wang, Shouzhi; Wang, Ning; Ma, Li; Leng, Li; Wang, Shengwen; Wang, Qigui; Wang, Yuxiang; Tang, Zhiquan; Li, Ning; Da, Yang; Li, Hui
2012-01-01
We conducted a selection signature analysis using the chicken 60k SNP chip in two chicken lines that had been divergently selected for abdominal fat content (AFC) for 11 generations. The selection signature analysis used multiple signals of selection, including long-range allele frequency differences between the lean and fat lines, long-range heterozygosity changes, linkage disequilibrium, haplotype frequencies, and extended haplotype homozygosity. Multiple signals of selection identified ten signatures on chromosomes 1, 2, 4, 5, 11, 15, 20, 26 and Z. The 0.73 Mb PC1/PCSK1 region of the Z chromosome at 55.43-56.16 Mb was the most heavily selected region. This region had 26 SNP markers and seven genes, Mar-03, SLC12A2, FBN2, ERAP1, CAST, PC1/PCSK1 and ELL2, where PC1/PCSK1 are the chicken/human names for the same gene. The lean and fat lines had two main haplotypes with completely opposite SNP alleles for the 26 SNP markers and were virtually line-specific, and had a recombinant haplotype with nearly equal frequency (0.193 and 0.196) in both lines. Other haplotypes in this region had negligible frequencies. Nine other regions with selection signatures were PAH-IGF1, TRPC4, GJD4-CCNY, NDST4, NOVA1, GALNT9, the ESRP2-GALR1 region with five genes, the SYCP2-CADH4 with six genes, and the TULP1-KIF21B with 14 genes. Genome-wide association analysis showed that nearly all regions with evidence of selection signature had SNP effects with genome-wide significance (P<10(-6)) on abdominal fat weight and percentage. The results of this study provide specific gene targets for the control of chicken AFC and a potential model of AFC in human obesity.
Controlling coupled bending-twisting vibrations of anisotropic composite wing
NASA Astrophysics Data System (ADS)
Ryabov, Victor; Yartsev, Boris
2018-05-01
The paper discusses the possibility to control coupled bending-twisting vibrations of anisotropic composite wing by means of the monoclinic structures in the reinforcement of the plating. Decomposing the potential straining energy and kinetic energy of natural vibration modes into interacting and non-interacting parts, it became possible to introduce the two coefficients that integrally consider the effect of geometry and reinforcement structure upon the dynamic response parameters of the wing. The first of these coefficients describes the elastic coupling of the natural vibration modes, the second coefficient describes the inertial one. The paper describes the numerical studies showing how the orientation of considerably anisotropic CRP layers in the plating affects natural frequencies, loss factors, coefficients of elastic and inertial coupling for several lower tones of natural bending-twisting vibrations of the wing. Besides, for each vibration mode, partial values of the above mentioned dynamic response parameters were determined by means of the relationships for orthotropic structures where instead of "free" shearing modulus in the reinforcement plant, "pure" shearing modulus is used. Joint analysis of the obtained results has shown that each pair of bending-twisting vibration modes has its orientation angle ranges of the reinforcing layers where the inertial coupling caused by asymmetry of the cross-section profile with respect to the main axes of inertia decreases, down to the complete extinction, due to the generation of the elastic coupling in the plating material. These ranges are characterized by the two main features: 1) the difference in the natural frequencies of the investigated pair of bending-twisting vibration modes is the minimum and 2) natural frequencies of bending-twisting vibrations belong to a stretch restricted by corresponding partial natural frequencies of the investigated pair of vibration modes. This result is of practical importance because it enables approximate analysis of real composite wings with complex geometry in the existing commercial software packages.
Entanglement and asymmetric steering over two octaves of frequency difference
NASA Astrophysics Data System (ADS)
Olsen, M. K.
2017-12-01
The development of quantum technologies which use quantum states of the light field interacting with other systems creates a demand for entangled states spanning wide frequency ranges. In this work we analyze a parametric scheme of cascaded harmonic generation which promises to deliver bipartite entangled states in which the two modes are separated by two octaves in frequency. This scheme is potentially very useful for applications in quantum communication and computation networks as well as providing for quantum interfaces between a wider range of light and atomic ensembles than is presently practicable. It doubles the frequency range over which entanglement is presently available.
Method and apparatus for coherent burst ranging
Wachter, Eric A.; Fisher, Walter G.
1998-01-01
A high resolution ranging method is described utilizing a novel modulated waveform, hereafter referred to as coherent burst modulation. In the coherent burst method, high frequency modulation of an acoustic or electromagnetic transmitter, such as a laser, is performed at a modulation frequency. This modulation frequency is transmitted quasi-continuously in the form of interrupted bursts of radiation. Energy from the transmitter is directed onto a target, interacts with the target, and the returning energy is collected. The encoded burst pattern contained in the collected return signal is detected coherently by a receiver that is tuned so as to be principally sensitive to the modulation frequency. The receiver signal is processed to determine target range using both time-of-flight of the burst envelope and phase shift of the high frequency modulation. This approach effectively decouples the maximum unambiguous range and range resolution relationship of earlier methods, thereby allowing high precision ranging to be conducted at arbitrarily long distances using at least one burst of encoded energy. The use of a receiver tuned to the high frequency modulation contained within the coherent burst vastly improves both sensitivity in the detection of the target return signal and rejection of background interferences, such as ambient acoustic or electromagnetic noise. Simultaneous transmission at several energies (or wavelengths) is possible by encoding each energy with a separate modulation frequency or pattern; electronic demodulation at the receiver allows the return pattern for each energy to be monitored independently. Radial velocity of a target can also be determined by monitoring change in phase shift of the return signal as a function of time.
Method and apparatus for coherent burst ranging
Wachter, E.A.; Fisher, W.G.
1998-04-28
A high resolution ranging method is described utilizing a novel modulated waveform, hereafter referred to as coherent burst modulation. In the coherent burst method, high frequency modulation of an acoustic or electromagnetic transmitter, such as a laser, is performed at a modulation frequency. This modulation frequency is transmitted quasi-continuously in the form of interrupted bursts of radiation. Energy from the transmitter is directed onto a target, interacts with the target, and the returning energy is collected. The encoded burst pattern contained in the collected return signal is detected coherently by a receiver that is tuned so as to be principally sensitive to the modulation frequency. The receiver signal is processed to determine target range using both time-of-flight of the burst envelope and phase shift of the high frequency modulation. This approach effectively decouples the maximum unambiguous range and range resolution relationship of earlier methods, thereby allowing high precision ranging to be conducted at arbitrarily long distances using at least one burst of encoded energy. The use of a receiver tuned to the high frequency modulation contained within the coherent burst vastly improves both sensitivity in the detection of the target return signal and rejection of background interferences, such as ambient acoustic or electromagnetic noise. Simultaneous transmission at several energies (or wavelengths) is possible by encoding each energy with a separate modulation frequency or pattern; electronic demodulation at the receiver allows the return pattern for each energy to be monitored independently. Radial velocity of a target can also be determined by monitoring change in phase shift of the return signal as a function of time. 12 figs.
Frequency modulation drive for a piezoelectric motor
Mittas, Anthony
2001-01-01
A piezoelectric motor has peak performance at a specific frequency f.sub.1 that may vary over a range of frequencies. A drive system is disclosed for operating such a motor at peak performance without feedback. The drive system consists of the motor and an ac source connected to power the motor, the ac source repeatedly generating a frequency over a range from f.sub.1 -.DELTA.x to f.sub.1 +.DELTA.y.
Andrews, W.J.; Fallon, J.D.; Kroening, S.E.
1995-01-01
Examination of water-quality data from widely distributed sampling networks of river sites and wells in the study area led to the following conclusions: 1) trace amounts of chlorinated VOC's were detected sporadically in waters of the Mississippi, Minnesota, St. Croix, and Vermillion Rivers; 2) benzene, ethylbenzene, toluene, and meta+paraxylene were detected sporadically in waters sampled from the chain of lakes used as the municipal supply for St. Paul, Minnesota; 3) the target VOC's were detected in less than five percent of ground-water samples at relatively low concentrations, generally near detection limits which ranged from 1 to 5 micrograms per liter; 4) VOC's were generally detected at similar frequencies, but at higher concentrations, in water samples from wells completed in sand and gravel aquifers than in water samples from wells completed in bedrock aquifers; 5) VOC's were most commonly detected in ground water in the vicinity of identifiable emission sites of VOC's, such as landfills, dumps, or major industries; 6) trichloroethene, a commonly used degreasing agent in dry cleaning, metal cleaning and cleaning septic lines, was the most frequently detected target VOC in ground water sampled from wells completed in both sand and gravel and bedrock aquifers; 7) wells producing water with detectable concentrations of the target VOC's tended to be shallower than wells producing water with no detectable concentrations of those compounds, but the differences in well depths were not statistically significant at a 95 percent confidence level; and 8) chlorination of water substantially increased the frequency of detection of trihalomethane compounds. The low frequencies of detection of the target VOC's and THM's in surface and ground water sampled from widely distributed sampling networks in the study area indicate that, although there are thousands of sites which can potentially emit these compounds to water, soil, and the atmosphere, these compounds have not had a widespread measurable effect on the quality of surface and ground water in the study area.
Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants.
Ahn, Dukju; Ghovanloo, Maysam
2016-02-01
This paper presents a design methodology for RF power transmission to millimeter-sized implantable biomedical devices. The optimal operating frequency and coil geometries are found such that power transfer efficiency (PTE) and tissue-loss-constrained allowed power are maximized. We define receiver power reception susceptibility (Rx-PRS) and transmitter figure of merit (Tx-FoM) such that their multiplication yields the PTE. Rx-PRS and Tx-FoM define the roles of the Rx and Tx in the PTE, respectively. First, the optimal Rx coil geometry and operating frequency range are identified such that the Rx-PRS is maximized for given implant constraints. Since the Rx is very small and has lesser design freedom than the Tx, the overall operating frequency is restricted mainly by the Rx. Rx-PRS identifies such operating frequency constraint imposed by the Rx. Secondly, the Tx coil geometry is selected such that the Tx-FoM is maximized under the frequency constraint at which the Rx-PRS was saturated. This aligns the target frequency range of Tx optimization with the frequency range at which Rx performance is high, resulting in the maximum PTE. Finally, we have found that even in the frequency range at which the PTE is relatively flat, the tissue loss per unit delivered power can be significantly different for each frequency. The Rx-PRS can predict the frequency range at which the tissue loss per unit delivered power is minimized while PTE is maintained high. In this way, frequency adjustment for the PTE and tissue-loss-constrained allowed power is realized by characterizing the Rx-PRS. The design procedure was verified through full-wave electromagnetic field simulations and measurements using de-embedding method. A prototype implant, 1 mm in diameter, achieved PTE of 0.56% ( -22.5 dB) and power delivered to load (PDL) was 224 μW at 200 MHz with 12 mm Tx-to-Rx separation in the tissue environment.
A pattern jitter free AFC scheme for mobile satellite systems
NASA Technical Reports Server (NTRS)
Yoshida, Shousei
1993-01-01
This paper describes a scheme for pattern jitter free automatic frequency control (AFC) with a wide frequency acquisition range. In this scheme, equalizing signals fed to the frequency discriminator allow pattern jitter free performance to be achieved for all roll-off factors. In order to define the acquisition range, frequency discrimination characateristics are analyzed on a newly derived frequency domain model. As a result, it is shown that a sufficiently wide acquisition range over a given system symbol rate can be achieved independent of symbol timing errors. Additionally, computer simulation demonstrates that frequency jitter performance improves in proportion to E(sub b)/N(sub 0) because pattern-dependent jitter is suppressed in the discriminator output. These results show significant promise for applciation to mobile satellite systems, which feature relatively low symbol rate transmission with an approximately 0.4-0.7 roll-off factor.
Saunders, Timothy J; Taylor, Alex H; Atkinson, Quentin D
2016-10-01
Monitoring cues, such as an image of a face or pair of eyes, have been found to increase prosocial behaviour in several studies. However, other studies have found little or no support for this effect. Here, we examined whether monitoring cues affect online donations to charity while manipulating the emotion displayed, the number of watchers and the cue type. We also include as statistical controls a range of likely covariates of prosocial behaviour. Using the crowdsourcing Internet marketplace, Amazon Mechanical Turk (MTurk), 1535 participants completed our survey and were given the opportunity to donate to charity while being shown an image prime. None of the monitoring primes we tested had a significant effect on charitable giving. By contrast, the control variables of culture, age, sex and previous charity giving frequency did predict donations. This work supports the importance of cultural differences and enduring individual differences in prosocial behaviour and shows that a range of artificial monitoring cues do not reliably boost online charity donation on MTurk.
Saunders, Timothy J.; Atkinson, Quentin D.
2016-01-01
Monitoring cues, such as an image of a face or pair of eyes, have been found to increase prosocial behaviour in several studies. However, other studies have found little or no support for this effect. Here, we examined whether monitoring cues affect online donations to charity while manipulating the emotion displayed, the number of watchers and the cue type. We also include as statistical controls a range of likely covariates of prosocial behaviour. Using the crowdsourcing Internet marketplace, Amazon Mechanical Turk (MTurk), 1535 participants completed our survey and were given the opportunity to donate to charity while being shown an image prime. None of the monitoring primes we tested had a significant effect on charitable giving. By contrast, the control variables of culture, age, sex and previous charity giving frequency did predict donations. This work supports the importance of cultural differences and enduring individual differences in prosocial behaviour and shows that a range of artificial monitoring cues do not reliably boost online charity donation on MTurk. PMID:27853533
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, Joerg F.; Hawellek, David J.; Corbetta, Maurizio; Siegel, Markus; Engel, Andreas K.
2013-01-01
Little is known about the brain-wide correlation of electrophysiological signals. Here we show that spontaneous oscillatory neuronal activity exhibits frequency-specific spatial correlation structure in the human brain. We developed an analysis approach that discounts spurious correlation of signal power caused by the limited spatial resolution of electrophysiological measures. We applied this approach to source estimates of spontaneous neuronal activity reconstructed from magnetoencephalography (MEG). Overall, correlation of power across cortical regions was strongest in the alpha to beta frequency range (8–32 Hz) and correlation patterns depended on the underlying oscillation frequency. Global hubs resided in the medial temporal lobe in the theta frequency range (4–6 Hz), in lateral parietal areas in the alpha to beta frequency range (8–23 Hz), and in sensorimotor areas for higher frequencies (32–45 Hz). Our data suggest that interactions in various large-scale cortical networks may be reflected in frequency specific power-envelope correlations. PMID:22561454
Effect of phase errors in stepped-frequency radar systems
NASA Astrophysics Data System (ADS)
Vanbrundt, H. E.
1988-04-01
Stepped-frequency waveforms are being considered for inverse synthetic aperture radar (ISAR) imaging from ship and airborne platforms and for detailed radar cross section (RCS) measurements of ships and aircraft. These waveforms make it possible to achieve resolutions of 1.0 foot by using existing radar designs and processing technology. One problem not yet fully resolved in using stepped-frequency waveform for ISAR imaging is the deterioration in signal level caused by random frequency error. Random frequency error of the stepped-frequency source results in reduced peak responses and increased null responses. The resulting reduced signal-to-noise ratio is range dependent. Two of the major concerns addressed in this report are radar range limitations for ISAR and the error in calibration for RCS measurements caused by differences in range between a passive reflector used for an RCS reference and the target to be measured. In addressing these concerns, NOSC developed an analysis to assess the tolerable frequency error in terms of resulting power loss in signal power and signal-to-phase noise.
Skinner, L.V.
1959-09-29
A narrow-band frequency-modulated distance measuring system is described. Reflected wave energy is fed into a mixer circuit together with a direct wave energy portion from the transmitter. These two input signals are out of phase by an amount proportional to the distance. Two band pass filter s select two different frequency components (both multiples of transmitter modulation frequency) from the beat frequency. These component frequencies are rectified and their voltage values, which are representative of those frequencies, are compared. It has been found that these voltages will have equal values producing a null output only when an object attains a preselected distance. The null output may be utilized to operate a normally closed relay, for example. At other ranges the voltage comparison will yield a voltage sufficient to keep the relay energized. Ranges may be changed by varying the degree of modulation of the transmitter carrier frequency. A particular advantage of this system lies in its high degree of accuracy throughout a range of distances approaching zero as a minimum.
Frequency-dependent ultrasound-induced transformation in E. coli.
Deeks, Jeremy; Windmill, James; Agbeze-Onuma, Maduka; Kalin, Robert M; Argondizza, Peter; Knapp, Charles W
2014-12-01
Ultrasound-enhanced gene transfer (UEGT) is continuing to gain interest across many disciplines; however, very few studies investigate UEGT efficiency across a range of frequencies. Using a variable frequency generator, UEGT was tested in E. coli at six ultrasonic frequencies. Results indicate frequency can significantly influence UEGT efficiency positively and negatively. A frequency of 61 kHz improved UEGT efficiency by ~70 % higher, but 99 kHz impeded UEGT to an extent worse than no ultrasound exposure. The other four frequencies (26, 133, 174, and 190 kHz) enhanced transformation compared to no ultrasound, but efficiencies did not vary. The influence of frequency on UEGT efficiency was observed across a range of operating frequencies. It is plausible that frequency-dependent dynamics of mechanical and chemical energies released during cavitational-bubble collapse (CBC) are responsible for observed UEGT efficiencies.
Coherent frequency division with a degenerate synchronously pumped optical parametric oscillator.
Wan, Chenchen; Li, Peng; Ruehl, Axel; Hartl, Ingmar
2018-03-01
Synchronously pumped optical parametric oscillators (OPOs) are important tools for frequency comb (FC) generation in the mid-IR spectral range, where few suitable laser gain materials exist. For degenerate OPOs, self-phase-locking to the pump FC has been demonstrated. Here, we present a phase noise study of the carrier envelope offset frequency, revealing a -6 dB reduction compared to the pump FC over a wide Fourier frequency range. These results demonstrate that a degenerate OPO can be an ideal coherent frequency divider without any excess noise.
Nanoelectromechanical systems: Nanodevice motion at microwave frequencies
NASA Astrophysics Data System (ADS)
Henry Huang, Xue Ming; Zorman, Christian A.; Mehregany, Mehran; Roukes, Michael L.
2003-01-01
It has been almost forgotten that the first computers envisaged by Charles Babbage in the early 1800s were mechanical and not electronic, but the development of high-frequency nanoelectromechanical systems is now promising a range of new applications, including sensitive mechanical charge detectors and mechanical devices for high-frequency signal processing, biological imaging and quantum measurement. Here we describe the construction of nanodevices that will operate with fundamental frequencies in the previously inaccessible microwave range (greater than 1 gigahertz). This achievement represents a significant advance in the quest for extremely high-frequency nanoelectromechanical systems.
Frequency stabilization for mobile satellite terminals via LORAN
NASA Technical Reports Server (NTRS)
Ernst, Gregory J.; Kee, Steven M.; Marquart, Robert C.
1990-01-01
Digital satellite communication systems require careful management of frequency stability. Historically, frequency stability has been accomplished by continuously powered, high cost, high performance reference oscillators. Today's low cost mobile satellite communication equipment must operate under wide ranging environmental conditions, stabilize quickly after application of power, and provide adequate performance margin to overcome RF link impairments unique to the land mobile environment. Methods for frequency stabilization in land mobile applications must meet these objectives without incurring excessive performance degradation. A frequency stabilization scheme utilizing the LORAN (Long Range Navigation) system is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soler, Roberto; Terradas, Jaume; Oliver, Ramón
It has been proposed that Alfvén waves play an important role in the energy propagation through the solar atmospheric plasma and its heating. Here we theoretically investigate the propagation of torsional Alfvén waves in magnetic flux tubes expanding from the photosphere up to the low corona and explore the reflection, transmission, and dissipation of wave energy. We use a realistic variation of the plasma properties and the magnetic field strength with height. Dissipation by ion–neutral collisions in the chromosphere is included using a multifluid partially ionized plasma model. Considering the stationary state, we assume that the waves are driven belowmore » the photosphere and propagate to the corona, while they are partially reflected and damped in the chromosphere and transition region. The results reveal the existence of three different propagation regimes depending on the wave frequency: low frequencies are reflected back to the photosphere, intermediate frequencies are transmitted to the corona, and high frequencies are completely damped in the chromosphere. The frequency of maximum transmissivity depends on the magnetic field expansion rate and the atmospheric model, but is typically in the range of 0.04–0.3 Hz. Magnetic field expansion favors the transmission of waves to the corona and lowers the reflectivity of the chromosphere and transition region compared to the case with a straight field. As a consequence, the chromospheric heating due to ion–neutral dissipation systematically decreases when the expansion rate of the magnetic flux tube increases.« less
LOFAR 150-MHz observations of SS 433 and W 50
NASA Astrophysics Data System (ADS)
Broderick, J. W.; Fender, R. P.; Miller-Jones, J. C. A.; Trushkin, S. A.; Stewart, A. J.; Anderson, G. E.; Staley, T. D.; Blundell, K. M.; Pietka, M.; Markoff, S.; Rowlinson, A.; Swinbank, J. D.; van der Horst, A. J.; Bell, M. E.; Breton, R. P.; Carbone, D.; Corbel, S.; Eislöffel, J.; Falcke, H.; Grießmeier, J.-M.; Hessels, J. W. T.; Kondratiev, V. I.; Law, C. J.; Molenaar, G. J.; Serylak, M.; Stappers, B. W.; van Leeuwen, J.; Wijers, R. A. M. J.; Wijnands, R.; Wise, M. W.; Zarka, P.
2018-04-01
We present Low-Frequency Array (LOFAR) high-band data over the frequency range 115-189 MHz for the X-ray binary SS 433, obtained in an observing campaign from 2013 February to 2014 May. Our results include a deep, wide-field map, allowing a detailed view of the surrounding supernova remnant W 50 at low radio frequencies, as well as a light curve for SS 433 determined from shorter monitoring runs. The complex morphology of W 50 is in excellent agreement with previously published higher frequency maps; we find additional evidence for a spectral turnover in the eastern wing, potentially due to foreground free-free absorption. Furthermore, SS 433 is tentatively variable at 150 MHz, with both a debiased modulation index of 11 per cent and a χ2 probability of a flat light curve of 8.2 × 10-3. By comparing the LOFAR flux densities with contemporaneous observations carried out at 4800 MHz with the RATAN-600 telescope, we suggest that an observed ˜0.5-1 Jy rise in the 150-MHz flux density may correspond to sustained flaring activity over a period of approximately 6 months at 4800 MHz. However, the increase is too large to be explained with a standard synchrotron bubble model. We also detect a wealth of structure along the nearby Galactic plane, including the most complete detection to date of the radio shell of the candidate supernova remnant G 38.7-1.4. This further demonstrates the potential of supernova remnant studies with the current generation of low-frequency radio telescopes.
NASA Technical Reports Server (NTRS)
Reddy, C. J.; Deshpande, M. D.
1997-01-01
Application of Asymptotic Waveform Evaluation (AWE) is presented in conjunction with a hybrid Finite Element Method (FEM)/Method of Moments (MoM) technique to calculate the input characteristics of cavity-backed aperture antennas over a frequency range. The hybrid FEM/MoM technique is used to form an integro-partial-differential equation to compute the electric field distribution of the cavity-backed aperture antenna. The electric field, thus obtained, is expanded in a Taylor series around the frequency of interest. The coefficients of 'Taylor series (called 'moments') are obtained using the frequency derivatives of the integro-partial-differential Equation formed by the hybrid FEM/MoM technique. Using the moments, the electric field in the cavity is obtained over a frequency range. Using the electric field at different frequencies, the input characteristics of the antenna are obtained over a wide frequency band. Numerical results for an open coaxial line, probe fed cavity, and cavity-backed microstrip patch antennas are presented. Good agreement between AWE and the exact solution over the frequency range is observed.
Sun, Chao; Pye, Stephen D.; Browne, Jacinta E.; Janeczko, Anna; Ellis, Bill; Butler, Mairead B.; Sboros, Vassilis; Thomson, Adrian J.W.; Brewin, Mark P.; Earnshaw, Charles H.; Moran, Carmel M.
2012-01-01
This study characterized the acoustic properties of an International Electromechanical Commission (IEC) agar-based tissue mimicking material (TMM) at ultrasound frequencies in the range 10–47 MHz. A broadband reflection substitution technique was employed using two independent systems at 21°C ± 1°C. Using a commercially available preclinical ultrasound scanner and a scanning acoustic macroscope, the measured speeds of sound were 1547.4 ± 1.4 m∙s−1 and 1548.0 ± 6.1 m∙s−1, respectively, and were approximately constant over the frequency range. The measured attenuation (dB∙cm−1) was found to vary with frequency f (MHz) as 0.40f + 0.0076f2. Using this polynomial equation and extrapolating to lower frequencies give values comparable to those published at lower frequencies and can estimate the attenuation of this TMM in the frequency range up to 47 MHz. This characterisation enhances understanding in the use of this TMM as a tissue equivalent material for high frequency ultrasound applications. PMID:22502881
Cochlear implantation: is hearing preservation necessary in severe to profound hearing loss?
Derinsu, Ufuk; Serin, Gediz Murat; Akdaş, Ferda; Batman, Çağlar
2011-03-01
The goal of the cochlear implant surgery is to place the electrode array with minimal damage to preserve the residual hearing. Round-window insertion can be performed in a manner that is potentially less traumatic than the standard cochleostomy. The purpose of the study was to investigate audiological results of the round-window approach using standard electrode. A retrospective study was performed to evaluate our experience in patients with implanted through round window between January 2007 and March 2009. Sixty patients had undergone cochlear implant surgery through the round window with full insertion of a standard electrode array. Preoperative and postoperative pure-tone thresholds were measured for implanted ears in the range of 250 to 4000 Hz. Within these 60 cases, 31 patients had been evaluated. The population comprised 16 women and 15 men. The mean age was 15.96 years (range, 4-64 years). Follow-up times ranged from 6 to 26 months. Preservation of low-frequency hearing (250 and 500 Hz) was achieved in 27 (87%) of 31 patients. Complete hearing preservation (all frequencies) was accomplished in 11 patients (35.48%). No hearing could be determined postoperatively in 4 patients (12.9%), having preoperative thresholds of 120 dB at 250, 500, and 1000 Hz. Round-window approach has been widely used for preservation of residual hearing. In our patients with severe to profound hearing loss, we preserved residual hearing. Although the residual hearing cannot be sufficient for using additional acoustic stimulation, the preserved residual hearing means minimal damage and a more convenient cochlea, so this is promising for future development.
Power allocation and range performance considerations for a dual-frequency EBPSK/MPPSK system
NASA Astrophysics Data System (ADS)
Yao, Yu; Wu, Lenan; Zhao, Junhui
2017-12-01
Extended binary phase shift keying/M-ary position phase shift keying (EBPSK/MPPSK)-MODEM provides radar and communication functions on a single hardware platform with a single waveform. However, its range estimation accuracy is worse than continuous-wave (CW) radar because of the imbalance of power in two carrier frequencies. In this article, the power allocation method for dual-frequency EBPSK/MPPSK modulated systems is presented. The power of two signal transmitters is adequately allocated to ensure that the power in two carrier frequencies is equal. The power allocation ratios for two types of modulation systems are obtained. Moreover, considerations regarding the range of operation of the dual-frequency system are analysed. In addition to theoretical considerations, computer simulations are provided to illustrate the performance.
SAR correlation technique - An algorithm for processing data with large range walk
NASA Technical Reports Server (NTRS)
Jin, M.; Wu, C.
1983-01-01
This paper presents an algorithm for synthetic aperture radar (SAR) azimuth correlation with extraneously large range migration effect which can not be accommodated by the existing frequency domain interpolation approach used in current SEASAT SAR processing. A mathematical model is first provided for the SAR point-target response in both the space (or time) and the frequency domain. A simple and efficient processing algorithm derived from the hybrid algorithm is then given. This processing algorithm enables azimuth correlation by two steps. The first step is a secondary range compression to handle the dispersion of the spectra of the azimuth response along range. The second step is the well-known frequency domain range migration correction approach for the azimuth compression. This secondary range compression can be processed simultaneously with range pulse compression. Simulation results provided here indicate that this processing algorithm yields a satisfactory compressed impulse response for SAR data with large range migration.
Opening complete band gaps in two dimensional locally resonant phononic crystals
NASA Astrophysics Data System (ADS)
Zhou, Xiaoling; Wang, Longqi
2018-05-01
Locally resonant phononic crystals (LRPCs) which have low frequency band gaps attract a growing attention in both scientific and engineering field recently. Wide complete locally resonant band gaps are the goal for researchers. In this paper, complete band gaps are achieved by carefully designing the geometrical properties of the inclusions in two dimensional LRPCs. The band structures and mechanisms of different types of models are investigated by the finite element method. The translational vibration patterns in both the in-plane and out-of-plane directions contribute to the full band gaps. The frequency response of the finite periodic structures demonstrate the attenuation effects in the complete band gaps. Moreover, it is found that the complete band gaps can be further widened and lowered by increasing the height of the inclusions. The tunable properties by changing the geometrical parameters provide a good way to open wide locally resonant band gaps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chao, Liu, E-mail: liu.chao@tufts.edu; Afsar, Mohammed N.; Ohkoshi, Shin-ichi
2015-05-07
In millimeter wave frequency range, hexagonal ferrites with high uniaxial anisotropic magnetic fields are used as absorbers. These ferrites include M-type barium ferrite (BaFe{sub 12}O{sub 19}) and strontium ferrite (SrFe{sub 12}O{sub 19}), which have natural ferromagnetic resonant frequency range from 40 GHz to 60 GHz. However, the higher frequency range lacks suitable materials that support the higher frequency ferromagnetic resonance. A series of gallium-substituted ε-iron oxides (ε-Ga{sub x}Fe{sub 2−x}O{sub 3}) are synthesized, which have ferromagnetic resonant frequencies appearing over the frequency range of 30 GHz to 150 GHz. The ε-Ga{sub x}Fe{sub 2−x}O{sub 3} is synthesized by the sol-gel method. The particlemore » sizes are observed to be smaller than 100 nm. In this paper, in-waveguide transmission and reflection method and the free space magneto-optical approach have been employed to study these newly developed ε-Ga{sub x}Fe{sub 2−x}O{sub 3} particles in millimeter waves. These techniques enable to obtain precise transmission spectra to determine the dielectric and magnetic properties of both isotropic and anisotropic ferrites in the microwave and millimeter wave frequency range from single set of direct measurements. The complex dielectric permittivity and magnetic permeability spectra of ε-Ga{sub x}Fe{sub 2−x}O{sub 3} are shown in this paper. Strong ferromagnetic resonances at different frequencies determined by the x parameter are found.« less
Cross-Linguistic Differences in Bilinguals' Fundamental Frequency Ranges
ERIC Educational Resources Information Center
Ordin, Mikhail; Mennen, Ineke
2017-01-01
Purpose: We investigated cross-linguistic differences in fundamental frequency range (FFR) in Welsh-English bilingual speech. This is the first study that reports gender-specific behavior in switching FFRs across languages in bilingual speech. Method: FFR was conceptualized as a behavioral pattern using measures of span (range of fundamental…
2011-04-28
quasiparticle poisoning which include a completely novel physical origin of these noises. We also proposed a model for excess low frequency flux noise which...and quasiparticle poisoning which include a completely novel physical origin of these noises. We also proposed a model for excess low frequency flux...metallic nanomechanical resonators, Phys. Rev. B 81, 184112 (2010). 3) L. Faoro, A. Kitaev and L. B. Ioffe, Quasiparticle poisoning and Josephson current
NASA Technical Reports Server (NTRS)
Wieserman, W. R.; Schwarze, G. E.; Niedra, J. M.
1992-01-01
The design of power magnetic components such as transformers, inductors, motors, and generators, requires specific knowledge about the magnetic and electrical characteristics of the magnetic materials used in these components. Limited experimental data exists that characterizes the performance of soft magnetic materials for the combined conditions of high temperature and high frequency over a wide flux density range. An experimental investigation of a 2V-49-Fe-49Co (Supermendur) and a grain oriented 3 Si-Fe (Magnesil) alloy was conducted over the temperature range of 23 to 300 C and frequency range of 0.1 to 10 kHz. The effects of temperature, frequency, and maximum flux density on the core loss and dynamic B-H loops for sinusoidal voltage excitation conditions are examined for each of these materials. A comparison of the core loss of these two materials is also made over the temperature and frequency range investigated.
NASA Technical Reports Server (NTRS)
Knapp, C. F.; Evans, J. M.; Grande, K. J.; Murphy, C. D.; Patwardhan, A. R.
1992-01-01
Changes in autonomic outflow to peripheral organs during the development of bedrest induced orthostatic intolerance have not been determined. Recent studies have indicated that spectral analysis provides an indirect assessment of these changes. Eight male subjects were studied before and after 22 hours of 6 degree head down bedrest plus Lasix (40 mg. P.P.). Cardiovascular spectra (using an autoregressive technique) were determined for heart rate (HR, ECG), arterial pressure (AP, Finapres), radial artery flow (RF, Hokansen) and respiration rate (RR, BoMed). Spectra were obtained from 2.5 minute segments during control, lower body negative pressure (minus 10, 20, 30, 40, 50 mmHg) and recovery. Bedrest increased HR spectra power in the low frequency (.001 to .041 Hz) range, increased RF power in the low and mid (.04 to .18 Hz) range and increased AP power in the high (.18 to .50 Hz) frequency range. Increasing levels of lower body negative pressure decreased HR power and increased RF power in the high frequency range and decreased AP power in the low frequency range. Since spectral power of HR in the high frequency range has been shown to indicate parasympathetically mediated regulation and power in the low and mid frequency ranges indicates a sympathetic / parasympathetic mixture, then both bedrest and lower body negative pressure appeared to shift sympathetic / parasympathetic balance toward sympathetic regulation of HR. The interpretation of the spectral content of AP and RF with respect to their autonomic origins remains unclear.
Multi-dynamic range compressional wave detection using optical-frequency comb
NASA Astrophysics Data System (ADS)
Minamikawa, Takeo; Masuoka, Takashi; Oe, Ryo; Nakajima, Yoshiaki; Yamaoka, Yoshihisa; Minoshima, Kaoru; Yasui, Takeshi
2018-02-01
Compressional wave detection is useful means for health monitoring of building, detection of abnormal vibration of moving objects, defect evaluation, and biomedical imaging such as echography and photoacoustic imaging. The frequency of the compressional wave is varied from quasi-static to a few tens of megahertz depending on applications. Since the dynamic range of general compressional wave detectors is limited, we need to choose a proper compressional wave detector depending on applications. For the compressional wave detection with wide dynamic range, two or more detectors with different detection ranges is required. However, these detectors with different detection ranges generally has different accuracy and precision, disabling the seamless detection over these detection ranges. In this study, we proposed a compressional wave detector employing optical frequency comb (OFC). The compressional wave was sensed with a part of an OFC cavity, being encoded into OFC. The spectrally encoded OFC was converted to radio-frequency by the frequency link nature of OFC. The compressional wave-encoded radio-frequency can therefore be directly measured with a high-speed photodetector. To enhance the dynamic range of the compressional wave detection, we developed a cavityfeedback-based system and a phase-sensitive detection system, both of which the accuracy and precision are coherently linked to these of the OFC. We provided a proof-of-principle demonstration of the detection of compressional wave from quasi-static to ultrasound wave by using the OFC-based compressional wave sensor. Our proposed approach will serve as a unique and powerful tool for detecting compressional wave versatile applications in the future.
Frequency response of portable PEF meters.
Hankinson, J L; Das, M K
1995-08-01
Peak expiratory flow (PEF) is a dynamic parameter and therefore requires a measuring device with a high-frequency response. This study evaluated the frequency-response characteristics of eight commercially available PEF meters, using simulated forced-expiratory maneuvers with a computer-controlled mechanical pump. Three different PEF levels were used (200, 400, and 600 L/min) at six levels of harmonic-frequency content similar to those observed in human subjects. For waveforms with higher frequency content (at the high end or above the physiologic range), the Assess, Vitalograph, Pocket Peak, and Spir-O-Flow PEF meters all overread PEF (greater than 15% difference from target values) at all three PEF levels. These results suggest that the frequency response of PEF meters is an important consideration in the selection of such meters and should be included in device requirements. The current practice of using various levels of American Thoracic Society (ATS) waveform 24 with its low-frequency content may not adequately evaluate the frequency characteristics of PEF meters. An upper range (5% of the fundamental frequency) of 12 Hz, within the range observed in normal subjects, appears to be more practical than an upper limit of 20 Hz.
Brown, Laura J E; Adlam, Tim; Hwang, Faustina; Khadra, Hassan; Maclean, Linda M; Rudd, Bridey; Smith, Tom; Timon, Claire; Williams, Elizabeth A; Astell, Arlene J
2016-08-01
Patterns of cognitive change over micro-longitudinal timescales (i.e., ranging from hours to days) are associated with a wide range of age-related health and functional outcomes. However, practical issues of conducting high-frequency assessments make investigations of micro-longitudinal cognition costly and burdensome to run. One way of addressing this is to develop cognitive assessments that can be performed by older adults, in their own homes, without a researcher being present. Here, we address the question of whether reliable and valid cognitive data can be collected over micro-longitudinal timescales using unsupervised cognitive tests.In study 1, 48 older adults completed two touchscreen cognitive tests, on three occasions, in controlled conditions, alongside a battery of standard tests of cognitive functions. In study 2, 40 older adults completed the same two computerized tasks on multiple occasions, over three separate week-long periods, in their own homes, without a researcher present. Here, the tasks were incorporated into a wider touchscreen system (Novel Assessment of Nutrition and Ageing (NANA)) developed to assess multiple domains of health and behavior. Standard tests of cognitive function were also administered prior to participants using the NANA system.Performance on the two "NANA" cognitive tasks showed convergent validity with, and similar levels of reliability to, the standard cognitive battery in both studies. Completion and accuracy rates were also very high. These results show that reliable and valid cognitive data can be collected from older adults using unsupervised computerized tests, thus affording new opportunities for the investigation of cognitive.
Cesium and Rubidium Frequency Standards Status and Performance on the GPS Program
NASA Technical Reports Server (NTRS)
VanMelle, M. J.
1996-01-01
This paper is an update of the on-orbit operational performance of the frequency standards on the last Block 1 Navstar satellite (GPS-10), the complete Block 2 Navstar satellites (GPS-13 to 21) and the Block 2A Navstar (GPS-22 to 40) satellites. Since the status of the GPS constellation is now at full operational capability (FOC), a minimum of twenty-four satellites are in position with all the necessary tests successfully completed. The evolution of frequency standards on board the GPS vehicles will be presented with corresponding results. Various methods and techniques will be presented to show on-orbit life time, down time, state of health telemetry, on-orbit trending and characterization of all the frequency standards. Other topics such as reliability, stability, clock quirks and idiosyncrasies of each vehicle will be covered.
Espí-López, Gemma V; Zurriaga-Llorens, Rosario; Monzani, Lucas; Falla, Deborah
2016-10-01
Manipulative techniques have shown promising results for relief of tension-type headache (TTH), however prior studies either lacked a control group, or suffered from poor methodological quality. The aim of this study was to compare the effect of spinal manipulation combined with massage versus massage alone on range of motion of the cervical spine, headache frequency, intensity and disability in patients with TTH. Randomized, single-blinded, controlled clinical trial. University clinic. We enrolled 105 subjects with TTH. Participants were divided into two groups: 1) manipulation and massage; 2) massage only (control). Four treatment sessions were applied over four weeks. The Headache Disability Inventory (HDI) and range of upper cervical and cervical motion were evaluated at baseline, immediately after the intervention and at a follow-up, 8 weeks after completing the intervention. Both groups demonstrated a large (ƒ=1.22) improvement on their HDI scores. Those that received manipulation reported a medium-sized reduction (ƒ=0.33) in headache frequency across all data points (P<0.05) compared to the control group. Both groups showed a large within-subject effect for upper cervical extension (ƒ=0.62), a medium-sized effect for cervical extension (ƒ=0.39), and large effects for upper cervical (ƒ=1.00) and cervical (ƒ=0.27) flexion. The addition of manipulation resulted in larger gains of upper cervical flexion range of motion, and this difference remained stable at the follow-up. These findings support the benefit of treating TTH with either massage or massage combined with a manipulative technique. However, the addition of manipulative technique was more effective for increasing range of motion of the upper cervical spine and for reducing the impact of headache. Although massage provided relief of headache in TTH sufferers, when combined with cervical manipulation, there was a stronger effect on range of upper cervical spine motion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeon, Jae; Chang, John
A band-notched spiral antenna having one or more spiral arms extending from a radially inner end to a radially outer end for transmitting or receiving electromagnetic radiation over a frequency range, and one or more resonance structures positioned adjacent one or more segments of the spiral arm associated with a notch frequency band or bands of the frequency range so as to resonate and suppress the transmission or reception of electromagnetic radiation over said notch frequency band or bands.
Marfeo, Elizabeth E; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K; Jette, Alan M
2014-07-01
The goal of this article was to investigate optimal functioning of using frequency vs. agreement rating scales in two subdomains of the newly developed Work Disability Functional Assessment Battery: the Mood & Emotions and Behavioral Control scales. A psychometric study comparing rating scale performance embedded in a cross-sectional survey used for developing a new instrument to measure behavioral health functioning among adults applying for disability benefits in the United States was performed. Within the sample of 1,017 respondents, the range of response category endorsement was similar for both frequency and agreement item types for both scales. There were fewer missing values in the frequency items than the agreement items. Both frequency and agreement items showed acceptable reliability. The frequency items demonstrated optimal effectiveness around the mean ± 1-2 standard deviation score range; the agreement items performed better at the extreme score ranges. Findings suggest an optimal response format requires a mix of both agreement-based and frequency-based items. Frequency items perform better in the normal range of responses, capturing specific behaviors, reactions, or situations that may elicit a specific response. Agreement items do better for those whose scores are more extreme and capture subjective content related to general attitudes, behaviors, or feelings of work-related behavioral health functioning. Copyright © 2014 Elsevier Inc. All rights reserved.
Popov, Vladimir V; Sysueva, Evgeniya V; Nechaev, Dmitry I; Lemazina, Alena A; Supin, Alexander Ya
2016-08-01
Using the auditory evoked response technique, sensitivity to local acoustic stimulation of the ventro-lateral head surface was investigated in a beluga whale (Delphinapterus leucas). The stimuli were tone pip trains of carrier frequencies ranging from 16 to 128 kHz with a pip rate of 1 kHz. For higher frequencies (90-128 kHz), the low-threshold point was located next to the medial side of the middle portion of the lower jaw. For middle (32-64 kHz) and lower (16-22.5 kHz) frequencies, the low-threshold point was located at the lateral side of the middle portion of the lower jaw. For lower frequencies, there was an additional low-threshold point next to the bulla-meatus complex. Based on these data, several frequency-specific paths of sound conduction to the auditory bulla are suggested: (i) through an area on the lateral surface of the lower jaw and further through the intra-jaw fat-body channel (for a wide frequency range); (ii) through an area on the ventro-lateral head surface and further through the medial opening of the lower jaw and intra-jaw fat-body channel (for a high-frequency range); and (iii) through an area on the lateral (near meatus) head surface and further through the lateral fat-body channel (for a low-frequency range).
Retrospective analysis of the efficacy and tolerability of levetiracetam in brain tumor patients.
Newton, Herbert B; Goldlust, Samuel A; Pearl, Dennis
2006-05-01
Seizures are a common complication of primary (PBT) and metastatic (MBT) brain tumors, affecting approximately 50% of all patients during the course of their illness. Anti-convulsant therapy of these tumor-induced seizures is often inadequate with conventional anti-epileptic drugs (AEDs), due to a variety of factors, including activation of glutaminergic NMDA receptors, immune-mediated neuronal damage, and anatomic alterations of neuronal input pathways. Levetiracetam (LEV) is a new AED with a novel mechanism of action, which includes reducing the Ca++ current through neuron-specific, high voltage activated Ca++ channels (n-type). Because of this unique mechanism, it has been postulated that LEV may be effective in controlling tumor-induced seizures. A retrospective chart review was performed of all patients who had received LEV for seizure control. Forty-one patients were reviewed (22 female, 19 male), with a median age of 47.5 years (range 25-81). There were 34 patients with PBT and 7 with MBT. LEV was used as an add-on AED in 33 patients and as monotherapy in eight patients, with a median dose of 1500 mg/day (range 500-3500). The baseline median seizure frequency for the cohort was 1 per week. After the addition of LEV and follow-up for a minimum of 4 weeks, the median seizure frequency was reduced to 0 per week (59% of patients noted complete seizure control). Overall, the seizure frequency was reduced in 90% of patients (P<0.0001; Sign test). The most common toxicity was somnolence, noted in 37% of patients. LEV was very effective and well tolerated in brain tumor patients with seizures, and should be considered for add-on therapy to current AEDs, or as a substitute anti-convulsant for monotherapy.
High precision moving magnet chopper for variable operation conditions
NASA Technical Reports Server (NTRS)
Aicher, Winfried; Schmid, Manfred
1994-01-01
In the context of an ESTEC technology contract, a Chopping Mechanism was developed and built with the Far Infrared and Submillimeter Telescope (FIRST) astronomy mission as a reference. The task of the mechanism is to tilt the subreflector of the telescope with an assumed mass of 2.5 kg about one chopping axis at nominal frequencies of up to 5 Hz and chopping angles of up to +/- 11.25 mrad with high efficiency (minimum time for position change). The chopping axis is required to run through the subreflector vertex. After performing a concept trade-off also considering the low operational temperatures in the 130 K range, a design using moving magnet actuators was found to be the favorite one. In addition, a bearing concept using flexible pivots was chosen to meet the high chopping accuracy required. With this approach, a very reliable design could be realized, since the actuators work without any mechanical contact between its moving and fixed parts, and the only bearings used are two flexible pivots supporting the subreflector mounting interface. The mechanism was completely built in titanium in a lightweight and stiff design. The moving magnet actuators were designed to meet the stringent requirements for minimum risetime (time necessary to move from one angular position to a new one) in the 20 msec range. The angular position and the corresponding chopping frequency as well can be arbitrarily selected by the user.
A Modular Low-Complexity ECG Delineation Algorithm for Real-Time Embedded Systems.
Bote, Jose Manuel; Recas, Joaquin; Rincon, Francisco; Atienza, David; Hermida, Roman
2018-03-01
This work presents a new modular and low-complexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets, and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform real-time delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in runtime to a wide range of modes and sampling rates, from a ultralow-power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete high-accuracy delineation mode, in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in the case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography Committee in the high-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultralow-power 8-MHz TI MSP430 series microcontroller ranges from 0.2% to 8.5% according to the mode used.
Mouratidou, Theodora; Ford, Fiona A; Fraser, Robert B
2011-04-01
The aim of this study was to examine the reproducibility and validity of a semi-quantitative food frequency questionnaire (FFQ) for assessing dietary intakes of low-income, Caucasian, English-speaking, postpartum women living in Sheffield, United Kingdom. Data was obtained from a cross-sectional sample of the 'Healthy Start' study; a population-based survey of mothers and infants. Participants completed two FFQs at 4 and 8 weeks postpartum. Measures from 24-hour dietary recalls (24HDRs) were collected at 4, 6, 8 and 12 weeks postpartum. In the reproducibility study, crude Pearson's correlation coefficients ranged from 0.40 (riboflavin) to 0.73 (thiamine), mean value 0.54. In the validation study, crude Pearson correlation coefficients between the FFQ and the measures from the 24HDRs ranged from 0.10 (B12) to 0.55 (manganese), mean value 0.34. Energy-adjustments and corrections for attenuation had no significant effect on the strength of the correlation both observed in the reproducibility and validity study. On average, 68% of the participants were classified correctly, and 3% were misclassified into the extreme opposite quintile of the distribution. The authors conclude that the questionnaire performed well for the majority of nutrients examined and that is a valid tool for ranking individuals according to nutrient distribution. © 2009 Blackwell Publishing Ltd.
An optical fiber Bragg grating and piezoelectric ceramic voltage sensor
NASA Astrophysics Data System (ADS)
Yang, Qing; He, Yanxiao; Sun, Shangpeng; Luo, Mandan; Han, Rui
2017-10-01
Voltage measurement is essential in many fields like power grids, telecommunications, metallurgy, railways, and oil production. A voltage-sensing unit, consisting of fiber Bragg gratings (FBGs) and piezoelectric ceramics, based on which an optical over-voltage sensor was proposed and fabricated in this paper. No demodulation devices like spectrometer or Fabry-Perot filter were needed to gain the voltage signal, and a relatively large sensing frequency range was acquired in this paper; thus, the cost of the sensing system is more acceptable in engineering application. The voltage to be measured was directly applied to the piezoelectric ceramic, and deformation of the ceramics and the grating would be caused because of the inverse piezoelectric effect. With a reference grating, the output light intensity change will be caused by the FBG center wavelength change; thus, the relationship between the applied voltage and the output light intensity was established. Validation of the sensor was accomplished in the frequency range from 50 Hz to 20 kHz and switching impulse waves with a test platform; good linearity of the input-output characteristic was achieved. A temperature validation test was completed, showing that the sensor maintains good temperature stability. Experimental results show that the optical over-voltage sensor can be used for voltage monitoring, and if applied with a voltage divider, the sensor can be used to measure high voltage.
An optical fiber Bragg grating and piezoelectric ceramic voltage sensor.
Yang, Qing; He, Yanxiao; Sun, Shangpeng; Luo, Mandan; Han, Rui
2017-10-01
Voltage measurement is essential in many fields like power grids, telecommunications, metallurgy, railways, and oil production. A voltage-sensing unit, consisting of fiber Bragg gratings (FBGs) and piezoelectric ceramics, based on which an optical over-voltage sensor was proposed and fabricated in this paper. No demodulation devices like spectrometer or Fabry-Perot filter were needed to gain the voltage signal, and a relatively large sensing frequency range was acquired in this paper; thus, the cost of the sensing system is more acceptable in engineering application. The voltage to be measured was directly applied to the piezoelectric ceramic, and deformation of the ceramics and the grating would be caused because of the inverse piezoelectric effect. With a reference grating, the output light intensity change will be caused by the FBG center wavelength change; thus, the relationship between the applied voltage and the output light intensity was established. Validation of the sensor was accomplished in the frequency range from 50 Hz to 20 kHz and switching impulse waves with a test platform; good linearity of the input-output characteristic was achieved. A temperature validation test was completed, showing that the sensor maintains good temperature stability. Experimental results show that the optical over-voltage sensor can be used for voltage monitoring, and if applied with a voltage divider, the sensor can be used to measure high voltage.
2013-01-01
Background The dimensional approach to autism spectrum disorder (ASD) considers ASD as the extreme of a dimension traversing through the entire population. We explored the potential utility of electroencephalography (EEG) functional connectivity as a biomarker. We hypothesized that individual differences in autistic traits of typical subjects would involve a long-range connectivity diminution within the delta band. Methods Resting-state EEG functional connectivity was measured for 74 neurotypical subjects. All participants also provided a questionnaire (Social Responsiveness Scale, SRS) that was completed by an informant who knows the participant in social settings. We conducted multivariate regression between the SRS score and functional connectivity in all EEG frequency bands. We explored modulations of network graph metrics characterizing the optimality of a network using the SRS score. Results Our results show a decay in functional connectivity mainly within the delta and theta bands (the lower part of the EEG spectrum) associated with an increasing number of autistic traits. When inspecting the impact of autistic traits on the global organization of the functional network, we found that the optimal properties of the network are inversely related to the number of autistic traits, suggesting that the autistic dimension, throughout the entire population, modulates the efficiency of functional brain networks. Conclusions EEG functional connectivity at low frequencies and its associated network properties may be associated with some autistic traits in the general population. PMID:23806204
Finnveden, Svante; Hörlin, Nils-Erik; Barbagallo, Mathias
2014-04-01
Viscoelastic properties of porous materials, typical of those used in vehicles for noise insulation and absorption, are estimated from measurements and inverse finite element procedures. The measurements are taken in a near vacuum and cover a broad frequency range: 20 Hz to 1 kHz. The almost cubic test samples were made of 25 mm foam covered by a "heavy layer" of rubber. They were mounted in a vacuum chamber on an aluminum table, which was excited in the vertical and horizontal directions with a shaker. Three kinds of response are measured allowing complete estimates of the viscoelastic moduli for isotropic materials and also providing some information on the degree of material anisotropicity. First, frequency independent properties are estimated, where dissipation is described by constant loss factors. Then, fractional derivative models that capture the variation with frequency of the stiffness and damping are adapted. The measurement setup is essentially two-dimensional and calculations are three-dimensional and for a state of plane strain. The good agreement between measured and calculated response provides some confidence in the presented procedures. If, however, the material model cannot fit the measurements well, the inverse procedure yields a certain degree of arbitrariness to the parameter estimation.
NASA Astrophysics Data System (ADS)
Wang, Ting; Sheng, Meiping; Ding, Xiaodong; Yan, Xiaowei
2018-03-01
This paper presents analysis on wave propagation and power flow in an acoustic metamaterial plate with lateral local resonance. The metamaterial is designed to have lateral local resonance systems attached to a homogeneous plate. Relevant theoretical analysis, numerical modelling and application prospect are presented. Results show that the metamaterial has two complete band gaps for flexural wave absorption and vibration attenuation. Damping can smooth and lower the metamaterial’s frequency responses in high frequency ranges at the expense of the band gap effect, and as an important factor to calculate the power flow is thoroughly investigated. Moreover, the effective mass density becomes negative and unbounded at specific frequencies. Simultaneously, power flow within band gaps are dramatically blocked from the power flow contour and power flow maps. Results from finite element modelling and power flow analysis reveal the working mechanism of the flexural wave attenuation and power flow blocked within the band gaps, where part of the flexural vibration is absorbed by the vertical resonator and the rest is transformed through four-link-mechanisms to the lateral resonators that oscillate and generate inertial forces indirectly to counterbalance the shear forces induced by the vibrational plate. The power flow is stored in the vertical and lateral local resonance, as well as in the connected plate.
High-speed acoustic communication by multiplexing orbital angular momentum
Shi, Chengzhi; Dubois, Marc; Wang, Yuan
2017-01-01
Long-range acoustic communication is crucial to underwater applications such as collection of scientific data from benthic stations, ocean geology, and remote control of off-shore industrial activities. However, the transmission rate of acoustic communication is always limited by the narrow-frequency bandwidth of the acoustic waves because of the large attenuation for high-frequency sound in water. Here, we demonstrate a high-throughput communication approach using the orbital angular momentum (OAM) of acoustic vortex beams with one order enhancement of the data transmission rate at a single frequency. The topological charges of OAM provide intrinsically orthogonal channels, offering a unique ability to multiplex data transmission within a single acoustic beam generated by a transducer array, drastically increasing the information channels and capacity of acoustic communication. A high spectral efficiency of 8.0 ± 0.4 (bit/s)/Hz in acoustic communication has been achieved using topological charges between −4 and +4 without applying other communication modulation techniques. Such OAM is a completely independent degree of freedom which can be readily integrated with other state-of-the-art communication modulation techniques like quadrature amplitude modulation (QAM) and phase-shift keying (PSK). Information multiplexing through OAM opens a dimension for acoustic communication, providing a data transmission rate that is critical for underwater applications. PMID:28652341
Bavarian, Niloofar; Flay, Brian R.; Ketcham, Patricia L.; Smit, Ellen; Kodama, Cathy; Martin, Melissa; Saltz, Robert F.
2014-01-01
Objective To test a theory-driven model of health behavior to predict the illicit use of prescription stimulants (IUPS) among college students. Participants A probability sample of 554 students from one university located in California (response rate = 90.52%). Methods Students completed a paper-based survey developed with guidance from the Theory of Triadic Influence. We first assessed normality of measures and checked for multicollinearity. A single structural equation model of frequency of IUPS in college was then tested using constructs from the theory’s three streams of influence (i.e., intrapersonal, social situation/context, and sociocultural environment) and four levels of causation (i.e., ultimate causes, distal influences, proximal predictors, and immediate precursors). Results Approximately 18% of students reported engaging in IUPS during college, with frequency of use ranging from never to 40 or more times per academic term. The model tested had strong fit and the majority of paths specified within and across streams were significant at the p<.01 level. Additionally, 46% of the variance in IUPS frequency was explained by the tested model. Conclusions Results suggest the utility of the TTI as an integrative model of health behavior, specifically in predicting IUPS, and provide insight on the need for multifaceted prevention and intervention efforts. PMID:24647369
Sánchez, Alberto; García, Manuel; Sebastián, Miguel Angel; Camacho, Ana María
2014-01-01
This work presents a hybrid (experimental-computational) application for improving the vibration behavior of structural components using a lightweight multilayer composite. The vibration behavior of a flat steel plate has been improved by the gluing of a lightweight composite formed by a core of polyurethane foam and two paper mats placed on its faces. This composite enables the natural frequencies to be increased and the modal density of the plate to be reduced, moving about the natural frequencies of the plate out of excitation range, thereby improving the vibration behavior of the plate. A specific experimental model for measuring the Operating Deflection Shape (ODS) has been developed, which enables an evaluation of the goodness of the natural frequencies obtained with the computational model simulated by the finite element method (FEM). The model of composite + flat steel plate determined by FEM was used to conduct parametric study, and the most influential factors for 1st, 2nd and 3rd mode were identified using a multifactor analysis of variance (Multifactor-ANOVA). The presented results can be easily particularized for other cases, as it may be used in cycles of continuous improvement as well as in the product development at the material, piece, and complete-system levels. PMID:24618779
Characterization of the relationship of the cure cycle chemistry to cure cycle processing properties
NASA Technical Reports Server (NTRS)
Kranbuehl, D. E.
1986-01-01
Dynamic Dielectric measurements made over a wide range of frequency provide a sensitive and convenient means for monitoring the cure process in thermosets and thermoplastics. The measurement of dielectric relaxation is one of only a few instrumental techniques available for studying molecular properties in both the liquid and solid states. Furthermore, it is probably the only convenient experimental technique for studying the polymerization process of going from a monomeric liquid of varying viscosity to a crosslinked, insoluble, high temperature solid. The objective of the research is to develop on-line dielectric instrumentation for quantitative nondestructive material evaluation and closed loop smart cure cycle control. The key is to relate the chemistry of the cure cycle process to the dielectric properties of the polymer system by correlating the time, temperature, and frequency dependent dielectric measurements with chemical characterization measurements. Measurement of the wide variation in magnitude of the complex permittivity with both frequency and state of cure, coupled with chemical characterization work, have been shown in the laboratory to have the potential to determine: resin quality, composition and age; cure cycle window boundaries; onset of flow and point of maximum flow; extent of and completion of reaction; evolution of volatiles; T sub g; and, crosslinking and molecular weight buildup.
Self-Reported Frequency and Perceived Severity of Being Bullied among Elementary School Students
ERIC Educational Resources Information Center
Chen, Li-Ming
2015-01-01
Background: This study reports students' perspectives on the frequency and perceived severity of being bullied. Methods: A sample of 1816 elementary school students completed self-report surveys of perceived severity and frequency of being bullied. A Rasch technique aligned different victimized behaviors on interval logit scales. A 4-fold schema…
47 CFR 15.611 - General technical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... spectrum by licensed services. These techniques may include adaptive or “notch” filtering, or complete... frequencies below 30 MHz, when a notch filter is used to avoid interference to a specific frequency band, the... below the applicable part 15 limits. (ii) For frequencies above 30 MHz, when a notch filter is used to...
Georgiades, Nikos P.; Polzik, Eugene S.; Kimble, H. Jeff
1999-02-02
An opto-electronic system and technique for comparing laser frequencies with large frequency separations, establishing new frequency standards, and achieving phase-sensitive detection at ultra high frequencies. Light responsive materials with multiple energy levels suitable for multi-photon excitation are preferably used for nonlinear mixing via quantum interference of different excitation paths affecting a common energy level. Demodulation of a carrier with a demodulation frequency up to 100's THZ can be achieved for frequency comparison and phase-sensitive detection. A large number of materials can be used to cover a wide spectral range including the ultra violet, visible and near infrared regions. In particular, absolute frequency measurement in a spectrum from 1.25 .mu.m to 1.66 .mu.m for fiber optics can be accomplished with a nearly continuous frequency coverage.
Methods and apparatus of entangled photon generation using four-wave mixing
Camacho, Ryan
2016-02-23
A non-linear optical device is provided. The device comprises an optical disk or ring microresonator fabricated from a material that exhibits an optical nonlinearity able to produce degenerate four-wave mixing (FWM) in response to a pump beam having a pump frequency in a specified effective range. The microresonator is conformed to exhibit an angular group velocity minimum at a pump frequency within the specified effective range such that there is zero angular group velocity dispersion at the pump frequency. We refer to such a pump frequency as the "zero dispersion frequency". In embodiments, excitation of the resonator by a pump beam of sufficient intensity at the zero-dispersion frequency causes the resonator to emit a frequency comb of entangled photon pairs wherein the respective frequencies in each pair are symmetrically placed about the zero-dispersion frequency.
Xia, Haiyun; Zhang, Chunxi
2010-03-01
An ultrafast and Doppler-free optical ranging system based on dispersive frequency-modulated interferometry is demonstrated. The principle is similar to the conventional frequency-modulated continuous-wave interferometry where the range information is derived from the beat frequency between the object signal and the reference signal. However, a passive and static frequency scanning is performed based on the chromatic dispersion of a transform-limited femtosecond pulse in the time domain. We point out that the unbalanced dispersion introduced in the Mach-Zehnder interferometer can be optimized to eliminate the frequency chirp in the temporal interferograms pertaining to the third order dispersion of the all-fiber system, if the dynamic range being considered is small. Some negative factors, such as the polarization instability of the femtosecond pulse, the power fluctuation of the optical signal and the nonuniform gain spectrum of the erbium-doped fiber amplifier lead to an obvious envelope deformation of the temporal interferograms from the Gaussian shape. Thus a new data processing method is proposed to guarantee the range resolution. In the experiment, the vibration of a speaker is measured. A range resolution of 1.59 microm is achieved with an exposure time of 394 fs at a sampling rate of 48.6 MHz.
Experiments and error analysis of laser ranging based on frequency-sweep polarization modulation
NASA Astrophysics Data System (ADS)
Gao, Shuyuan; Ji, Rongyi; Li, Yao; Cheng, Zhi; Zhou, Weihu
2016-11-01
Frequency-sweep polarization modulation ranging uses a polarization-modulated laser beam to determine the distance to the target, the modulation frequency is swept and frequency values are measured when transmitted and received signals are in phase, thus the distance can be calculated through these values. This method gets much higher theoretical measuring accuracy than phase difference method because of the prevention of phase measurement. However, actual accuracy of the system is limited since additional phase retardation occurs in the measuring optical path when optical elements are imperfectly processed and installed. In this paper, working principle of frequency sweep polarization modulation ranging method is analyzed, transmission model of polarization state in light path is built based on the theory of Jones Matrix, additional phase retardation of λ/4 wave plate and PBS, their impact on measuring performance is analyzed. Theoretical results show that wave plate's azimuth error dominates the limitation of ranging accuracy. According to the system design index, element tolerance and error correcting method of system is proposed, ranging system is built and ranging experiment is performed. Experiential results show that with proposed tolerance, the system can satisfy the accuracy requirement. The present work has a guide value for further research about system design and error distribution.
The noseleaf of Rhinolophus formosae focuses the Frequency Modulated (FM) component of the calls
Vanderelst, Dieter; Lee, Ya-Fu; Geipel, Inga; Kalko, Elisabeth K. V.; Kuo, Yen-Min; Peremans, Herbert
2013-01-01
Bats of the family Rhinolophidae emit their echolocation calls through their nostrils and feature elaborate noseleaves shaping the directionality of the emissions. The calls of these bats consist of a long constant-frequency component preceded and/or followed by short frequency-modulated sweeps. While Rhinolophidae are known for their physiological specializations for processing the constant frequency part of the calls, previous evidence suggests that the noseleaves of these animals are tuned to the frequencies in the frequency modulated components of the calls. In this paper, we seek further support for this hypothesis by simulating the emission beam pattern of the bat Rhinolophus formosae. Filling the furrows of lancet and removing the basal lappets (i.e., two flaps on the noseleaf) we find that these conspicuous features of the noseleaf focus the emitted energy mostly for frequencies in the frequency-modulated components. Based on the assumption that this component of the call is used by the bats for ranging, we develop a qualitative model to assess the increase in performance due to the furrows and/or the lappets. The model confirms that both structures decrease the ambiguity in selecting relevant targets for ranging. The lappets and the furrows shape the emission beam for different spatial regions and frequency ranges. Therefore, we conclude that the presented evidence is in line with the hypothesis that different parts of the noseleaves of Rhinolophidae are tuned to different frequency ranges with at least some of the most conspicuous ones being tuned to the frequency modulated components of the calls—thus yielding strong evidence for the sensory importance of the component. PMID:23882226
NASA Astrophysics Data System (ADS)
Irwansyah, Kuse, Naoyuki; Usagawa, Tsuyoshi
2017-08-01
Directivity pattern of an ordinary loudspeaker becomes more directive at higher frequencies. However, because a single loudspeaker tends to radiate uniformly in all directions at low frequencies, reverberation from surrounding building walls may affect speech intelligibility when installing a multiple-loudspeaker system at crossroads. As an alternative, a sharply directive sound source is recommended to be used, but in many cases the directivity of an ordinary loudspeaker is less sharp at lower frequencies. Therefore, in order to overcome such a limitation, this paper discusses the possibility of using four loudspeakers under active control to realize a quadrupole radiation pattern in low frequency range. In this study, the radiation pattern of a primary loudspeaker and three secondary loudspeakers has been modelled. By placing the loudspeakers close together in the direction of 0°, 90°, 180°, and 270°, it was theoretically demonstrated that a quadrupole radiation pattern can be shaped in the target frequency range up to 600 Hz by simply controlling the directivity in three of four directions which are 45°, 135°, 225°, and 315°. Although, the radiation pattern model is far from realistic configurations and conditions, it is possible to realize a quadrupole radiation pattern in the low frequency range.
Yang, Yaowen; Divsholi, Bahador Sabet
2010-01-01
The electromechanical (EM) impedance technique using piezoelectric lead zirconate titanate (PZT) transducers for structural health monitoring (SHM) has attracted considerable attention in various engineering fields. In the conventional EM impedance technique, the EM admittance of a PZT transducer is used as a damage indicator. Statistical analysis methods such as root mean square deviation (RMSD) have been employed to associate the damage level with the changes in the EM admittance signatures, but it is difficult to determine the location of damage using such methods. This paper proposes a new approach by dividing the large frequency (30–400 kHz) range into sub-frequency intervals and calculating their respective RMSD values. The RMSD of the sub-frequency intervals (RMSD-S) will be used to study the severity and location of damage. An experiment is carried out on a real size concrete structure subjected to artificial damage. It is observed that damage close to the PZT changes the high frequency range RMSD-S significantly, while the damage far away from the PZT changes the RMSD-S in the low frequency range significantly. The relationship between the frequency range and the PZT sensing region is also presented. Finally, a damage identification scheme is proposed to estimate the location and severity of damage in concrete structures. PMID:22163548
Biodynamic response at the palm of the human hand subjected to a random vibration.
Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E
2005-01-01
This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system resonated mostly in the frequency range of 20 to 50 Hz, depending on the specific test treatment and individual characteristics. The maximum vibration power transmission through the palm occurred at the resonant frequency. Increasing the effective palm force generally increased the BR magnitude and resonant frequency. The apparent stiffness measured at the middle frequencies (80-100 Hz) is correlated to the BR in almost the entire frequency range (20-1,000 Hz). Under the same palm force, the push-only action corresponded to the highest BR values while the grip-only action generally produced the lowest values. Since the resonant frequency range matches the dominant vibration frequency range of many percussive tools, it is anticipated that the palm BR and vibration power transmission may have an association with vibration-induced injuries or disorders in the wrist-arm system among the workers using these tools.
Miller, Patrick J O; Samarra, Filipa I P; Perthuison, Aurélie D
2007-06-01
This study investigates how particular received spectral characteristics of stereotyped calls of sexually dimorphic adult killer whales may be influenced by caller sex, orientation, and range. Calls were ascribed to individuals during natural behavior using a towed beamforming array. The fundamental frequency of both high-frequency and low-frequency components did not differ consistently by sex. The ratio of peak energy within the fundamental of the high-frequency component relative to summed peak energy in the first two low-frequency component harmonics, and the number of modulation bands off the high-frequency component, were significantly greater when whales were oriented towards the array, while range and adult sex had little effect. In contrast, the ratio of peak energy in the first versus second harmonics of the low-frequency component was greater in calls produced by adult females than adult males, while orientation and range had little effect. The dispersion of energy across harmonics has been shown to relate to body size or sex in terrestrial species, but pressure effects during diving are thought to make such a signal unreliable in diving animals. The observed spectral differences by signaler sex and orientation suggest that these types of information may be transmitted acoustically by freely diving killer whales.